WorldWideScience

Sample records for screen control system

  1. Telescope Array Control System Based on Wireless Touch Screen Platform

    Science.gov (United States)

    Fu, Xia-nan; Huang, Lei; Wei, Jian-yan

    2017-10-01

    Ground-based Wide Angle Cameras (GMAC) are the ground-based observational facility for the SVOM (Space Variable Object Monitor) astronomical satellite of Sino-French cooperation, and Mini-GWAC is the pathfinder and supplement of GWAC. In the context of the Mini-GWAC telescope array, this paper introduces the design and implementation of a kind of telescope array control system based on the wireless touch screen platform. We describe the development and implementation of the system in detail in terms of control system principle, system hardware structure, software design, experiment, and test etc. The system uses a touch-control PC which is based on the Windows CE system as the upper computer, while the wireless transceiver module and PLC (Programmable Logic Controller) are taken as the system kernel. It has the advantages of low cost, reliable data transmission, and simple operation. And the control system has been applied to the Mini-GWAC successfully.

  2. Lighting Control System for Premises with Display Screen Equipment

    Science.gov (United States)

    Kudryashov, A. V.

    2017-11-01

    The use of Display Screen Equipment (DSE) at enterprises allows one to increase the productivity and safety of production, minimize the number of personnel and leads to the simplification of the work of specialists, but on the other side, changes usual working conditions. If the personnel works with displays, visual fatigue develops more quickly which contributes to the emergence of nervous tension, stress and possible erroneous actions. Low interest of the lighting control system developers towards the rooms with displays is dictated by special requirements for coverage by sanitary and hygienic standards (limiting excess workplace illumination). We decided to create a combined lighting system which works considering daylight illumination and artificial light sources. The brightness adjustment of the LED lamps is carried out according to the DALI protocol, adjustment of the natural illumination by means of smart glasses. The technical requirements for a lighting control system, the structural-functional scheme and the algorithm for controlling the operation of the system have been developed. The elements of control units, sensors and actuators have been selected.

  3. Active versus passive screening for entrance control

    International Nuclear Information System (INIS)

    McCormick, N.J.

    1976-01-01

    The benefits of different entrance control actions are quantitatively assessed by defining a relative improvement index for the screening activity. Three classes of entrance control measures are investigated: the use of a purely active screening measure (such as a portal monitor), the use of a purely passive screening measure (such as personality typing), and the combined use of active and passive measures. Active entrance control measures have been studied previously [McCormick and Erdmann, Nucl. Mat. Manag. 4, (1975)] where it was determined that the relative improvement index is approximately related to the nondetection probability factor r for the protective system by (1-r + r ln r). It is shown here that the relative improvement index for a purely passive screening system also can be approximately expressed in a convenient manner. Because the probability is very small that a sabotage or diversion action would be attempted, the result for passive screening, multiplied by r, may be combined with the factor (1-r + r ln r) to give the relative improvement index for a combined, active-and-passive entrance control system. Results from simple example calculations indicate that passive screening of nuclear plant personnel or applicants for such positions is orders-of-magnitude less effective than portal monitors or reasonable improvements in them. 5 tables

  4. Screen-based process control in nuclear plants

    International Nuclear Information System (INIS)

    Hinz, W.; Arnoldt, C.; Hessler, C.

    1993-01-01

    Requirements, development and conceptual design of a screen-based control room for nuclear power plants are outlined. The control room consists of three or four equally equipped operator workstations comprising screens for process information and manual process control. A plant overview will assist the coordination among the operators. A safety classified backup system (safety control area) is provided to cover postulated failures of the control means. Some aspects of ergonomical validation and of future development trends are discussed. (orig.) [de

  5. Control system design of the CERN/CMS tracker thermal screen

    CERN Document Server

    Carrone, E

    2003-01-01

    The Tracker is one of the CMS (Compact Muon Solenoid experiment) subdetectors to be installed at the LHC (Large Hadron Collider) accelerator, scheduled to start data taking in 2007 at CERN (European Organization for Nuclear Research). The tracker will be operated at a temperature of -10 degree C in order to reduce the radiation damage on the silicon detectors; hence, an insulated environment has to be provided by means of a screen that introduces a thermal separation between the Tracker and the neighboring detection systems. The control system design includes a formal description of the process by means of a thermodynamic model; then, the electrical equivalence is derived. The transfer function is inferred by the ratio of the voltage on the outer skin and the voltage input, i.e. the ratio of the temperature outside the tracker and the heat generated (which is the controlled variable). A PID (Proportional Integral Derivative) controller has been designed using MatLab. The results achieved so far prove that thi...

  6. Realization of Intelligent Measurement and Control System for Limb Rehabilitation Based on PLC and Touch Screen

    Science.gov (United States)

    Liu, Xiangquan

    According to the treatment needs of patients with limb movement disorder, on the basis of the limb rehabilitative training prototype, function of measure and control system are analyzed, design of system hardware and software is completed. The touch screen which is adopt as host computer and man-machine interaction window is responsible for sending commands and training information display; The PLC which is adopt as slave computer is responsible for receiving control command from touch screen, collecting the sensor data, regulating torque and speed of motor by analog output according to the different training mode, realizing ultimately active and passive training for limb rehabilitation therapy.

  7. The use of twin-screen-based WIMPS in spacecraft control

    Science.gov (United States)

    Klim, R. D.

    1990-10-01

    The ergonomic problems of designing a sophisticated Windows Icons Mouse Pop-up (WIMP) based twin screen workstation are outlined. These same problems will be encountered by future spacecraft controllers. The design of a modern, advanced workstation for use on a distributed multicontrol center in a multisatellite control system is outlined. The system uses access control mechanisms to ensure that only authorized personnel can undertake certain operations on the workstation. Rules governing the use of windowing features, screen attributes, icons, keyboard and mouse in spacecraft control are discussed.

  8. Milestones in screen-based process control

    International Nuclear Information System (INIS)

    Guesnier, G.P.

    1995-01-01

    The German approach is based on the utilisation of the conceptual elements of the PRISCA information system developed by Siemens and on operational experience with screen-based process control in a conventional power plant. In the French approach, the screen-based control room for the N4 plants, designed from scratch, has undergone extensive simulator tests for validation before going into realisation. It is now used in the commissioning phase of the first N4 plants. The design of the control room for the European Pressurized Water Reactor will be based on the common experience of Siemens and Electricite de France. Its main elements are several separate operator workstations, a safety control area used as a back-up for postulated failures of the workstations, and a commonly utilisable plant overview for the operators' coordination. (orig./HP) [de

  9. Compatibility of automatic exposure control with new screen phosphors in diagnostic roentgenography

    International Nuclear Information System (INIS)

    Mulvaney, J.A.

    1982-01-01

    Automatic exposure control systems are used in diagnostic roentgenography to obtain proper film density for a variety of patient examinations and roentgenographic techniques. Most automatic exposure control systems have been designed for use with par speed, calcium tungstate intensifying screens. The use of screens with faster speeds and new phosphor materials has put extreme demands on present systems. The performance of a representative automatic exposure control system is investigated to determine its ability to maintain constant film density over a wide range of x-ray tube voltages and acrylic phantom thicknesses with four different intensifying screen phosphors. The effects of x-ray energy dependence, generator switching time and stored change are investigated. The system is able to maintain film density to within plus or minus 0.2 optical density units for techniques representing adult patients. A single nonadjustable tube voltage compensation circuit is adequate for the four different screen phosphors for x-ray tube voltages above sixty peak kilovolts. For techniques representing pediatric patients at high x-ray tube voltages, excess film density occurs due to stored charge in the transformer and high-voltage cables. An anticipation circuit in the automatic exposure control circuit can be modified to correct for stored charge effects. In a seperate experiment the energy dependence of three different ionization chamber detectors used in automatic exposure control systems is compared directly with the energy dependence of three different screen phosphors. The data on detector sensitivity and screen speed are combined to predict the best tube voltage compensation for each combination of screen and detector

  10. Beam screen cryogenic control improvements for the LHC run 2

    CERN Document Server

    AUTHOR|(CDS)2068353; Rogez, Edouard; Blanco Vinuela, Enrique; Ferlin, Gerard; Tovar-Gonzalez, Antonio

    2017-01-01

    This paper presents the improvements made on the cryogenic control system for the LHC beam screens. The regulation objective is to maintain an acceptable temperature range around 20 K which simultaneously ensures a good LHC beam vacuum and limits cryogenic heat loads. In total, through the 27 km of the LHC machine, there are 485 regulation loops affected by beam disturbances. Due to the increase of the LHC performance during Run 2, standard PID controllers cannot keeps the temperature transients of the beam screens within desired limits. Several alternative control techniques have been studied and validated using dynamic simulation and then deployed on the LHC cryogenic control system in 2015. The main contribution is the addition of a feed-forward control in order to compensate the beam effects on the beam screen temperature based on the main beam parameters of the machine in real time.

  11. Laser display system for multi-depth screen projection scenarios.

    Science.gov (United States)

    La Torre, J Pablo; Mayes, Nathan; Riza, Nabeel A

    2017-11-10

    Proposed is a laser projection display system that uses an electronically controlled variable focus lens (ECVFL) to achieve sharp and in-focus image projection over multi-distance three-dimensional (3D) conformal screens. The system also functions as an embedded distance sensor that enables 3D mapping of the multi-level screen platform before the desired laser scanned beam focused/defocused projected spot sizes are matched to the different localized screen distances on the 3D screen. Compared to conventional laser scanning and spatial light modulator (SLM) based projection systems, the proposed design offers in-focus non-distorted projection over a multi-distance screen zone with varying depths. An experimental projection system for a screen depth variation of 65 cm is demonstrated using a 633 nm laser beam, 3 KHz scan speed galvo-scanning mirrors, and a liquid-based ECVFL. As a basic demonstration, an in-house developed MATLAB based graphic user interface is deployed to work along with the laser projection display, enabling user inputs like text strings or predefined image projection. The user can specify projection screen distance, scanned laser linewidth, projected text font size, projected image dimensions, and laser scanning rate. Projected images are shown highlighting the 3D control capabilities of the display, including the production of a non-distorted image onto two-depths versus a distorted image via dominant prior-art projection methods.

  12. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  13. Newborn screening healthcare information system based on service-oriented architecture.

    Science.gov (United States)

    Hsieh, Sung-Huai; Hsieh, Sheau-Ling; Chien, Yin-Hsiu; Weng, Yung-Ching; Hsu, Kai-Ping; Chen, Chi-Huang; Tu, Chien-Ming; Wang, Zhenyu; Lai, Feipei

    2010-08-01

    In this paper, we established a newborn screening system under the HL7/Web Services frameworks. We rebuilt the NTUH Newborn Screening Laboratory's original standalone architecture, having various heterogeneous systems operating individually, and restructured it into a Service-Oriented Architecture (SOA), distributed platform for further integrity and enhancements of sample collections, testing, diagnoses, evaluations, treatments or follow-up services, screening database management, as well as collaboration, communication among hospitals; decision supports and improving screening accuracy over the Taiwan neonatal systems are also addressed. In addition, the new system not only integrates the newborn screening procedures among phlebotomy clinics, referral hospitals, as well as the newborn screening center in Taiwan, but also introduces new models of screening procedures for the associated, medical practitioners. Furthermore, it reduces the burden of manual operations, especially the reporting services, those were heavily dependent upon previously. The new system can accelerate the whole procedures effectively and efficiently. It improves the accuracy and the reliability of the screening by ensuring the quality control during the processing as well.

  14. Dynamitron control systems

    International Nuclear Information System (INIS)

    Lisanti, Thomas F.

    2005-01-01

    The Dynamitron control system utilizes the latest personal computer technology in control circuitry and components. Both the DPC-2000 and newer Millennium series of control systems make use of their modular architecture in both software and hardware to keep up with customer and engineering demands. This also allows the main structure of the software to remain constant for the user while software drivers are easily changed as hardware demands are modified and improved. The system is presented as four units; the Remote I/O (Input/Output), Local Analog and Digital I/O, Operator Interface and the Main Computer. The operator is provided with a selection of many informative screen displays. The control program handles all graphic screen displays and the updating of these screens directly; it does not communicate to a display terminal. This adds to the quick response and excellent operator feedback received while operating the accelerator. The CPU also has the ability to store and record all process variable setpoints for each product that will be treated. All process parameters are printed to a report at regular intervals during a process run for record keeping

  15. Continuous Membrane-Based Screening System for Biocatalysis

    Directory of Open Access Journals (Sweden)

    Matthias Kraume

    2011-02-01

    Full Text Available The use of membrane reactors for enzymatic and co-factor regenerating reactions offers versatile advantages such as higher conversion rates and space-time-yields and is therefore often applied in industry. However, currently available screening and kinetics characterization systems are based on batch and fed-batch operated reactors and were developed for whole cell biotransformations rather than for enzymatic catalysis. Therefore, the data obtained from such systems has only limited transferability for continuous membrane reactors. The aim of this study is to evaluate and to improve a novel screening and characterization system based on the membrane reactor concept using the enzymatic hydrolysis of cellulose as a model reaction. Important aspects for the applicability of the developed system such as long-term stability and reproducibility of continuous experiments were very high. The concept used for flow control and fouling suppression allowed control of the residence time with a high degree of precision (±1% accuracy in a long-term study (>100 h.

  16. Smart material screening machines using smart materials and controls

    Science.gov (United States)

    Allaei, Daryoush; Corradi, Gary; Waigand, Al

    2002-07-01

    The objective of this product is to address the specific need for improvements in the efficiency and effectiveness in physical separation technologies in the screening areas. Currently, the mining industry uses approximately 33 billion kW-hr per year, costing 1.65 billion dollars at 0.05 cents per kW-hr, of electrical energy for physical separations. Even though screening and size separations are not the single most energy intensive process in the mining industry, they are often the major bottleneck in the whole process. Improvements to this area offer tremendous potential in both energy savings and production improvements. Additionally, the vibrating screens used in the mining processing plants are the most costly areas from maintenance and worker health and safety point of views. The goal of this product is to reduce energy use in the screening and total processing areas. This goal is accomplished by developing an innovative screening machine based on smart materials and smart actuators, namely smart screen that uses advanced sensory system to continuously monitor the screening process and make appropriate adjustments to improve production. The theory behind the development of Smart Screen technology is based on two key technologies, namely smart actuators and smart Energy Flow ControlT (EFCT) strategies, developed initially for military applications. Smart Screen technology controls the flow of vibration energy and confines it to the screen rather than shaking much of the mass that makes up the conventional vibratory screening machine. Consequently, Smart Screens eliminates and downsizes many of the structural components associated with conventional vibratory screening machines. As a result, the surface area of the screen increases for a given envelope. This increase in usable screening surface area extends the life of the screens, reduces required maintenance by reducing the frequency of screen change-outs and improves throughput or productivity.

  17. 3D mosquito screens to create window double screen traps for mosquito control.

    Science.gov (United States)

    Khattab, Ayman; Jylhä, Kaisa; Hakala, Tomi; Aalto, Mikko; Malima, Robert; Kisinza, William; Honkala, Markku; Nousiainen, Pertti; Meri, Seppo

    2017-08-29

    Mosquitoes are vectors for many diseases such as malaria. Insecticide-treated bed nets and indoor residual spraying of insecticides are the principal malaria vector control tools used to prevent malaria in the tropics. Other interventions aim at reducing man-vector contact. For example, house screening provides additive or synergistic effects to other implemented measures. We used commercial screen materials made of polyester, polyethylene or polypropylene to design novel mosquito screens that provide remarkable additional benefits to those commonly used in house screening. The novel design is based on a double screen setup made of a screen with 3D geometric structures parallel to a commercial mosquito screen creating a trap between the two screens. Owing to the design of the 3D screen, mosquitoes can penetrate the 3D screen from one side but cannot return through the other side, making it a unidirectional mosquito screen. Therefore, the mosquitoes are trapped inside the double screen system. The permissiveness of both sides of the 3D screens for mosquitoes to pass through was tested in a wind tunnel using the insectary strain of Anopheles stephensi. Among twenty-five tested 3D screen designs, three designs from the cone, prism, or cylinder design groups were the most efficient in acting as unidirectional mosquito screens. The three cone-, prism-, and cylinder-based screens allowed, on average, 92, 75 and 64% of Anopheles stephensi mosquitoes released into the wind tunnel to penetrate the permissive side and 0, 0 and 6% of mosquitoes to escape through the non-permissive side, respectively. A cone-based 3D screen fulfilled the study objective. It allowed capturing 92% of mosquitoes within the double screen setup inside the wind tunnel and blocked 100% from escaping. Thus, the cone-based screen effectively acted as a unidirectional mosquito screen. This 3D screen-based trap design could therefore be used in house screening as a means of avoiding infective bites and

  18. A Desktop Screen Sharing System based on Various Connection Methods

    Science.gov (United States)

    Negishi, Yuya; Kawaguchi, Nobuo

    Recently it became very common to use information devices such as PCs during presentations and discussions. In these situations, a need arises for techniques that allow a smooth switch of presenters without changing cables, or an easy screen sharing in case of remote videoconferences. In this paper, we propose a desktop screen sharing system that can be used for such purposes and situations. For that, we designed an automatic control of connections in the VNC system that can be operated remotely over the network. We also suggested an interface that assigns a role such as “Screen sender" or “Screen receiver" to each terminal. In the proposed system, while sharing a screen between multiple terminals, one can easily display and browse the screen without having to understand how the others are connected. We also implemented a “role card" using contactless IC card, where roles are assigned only by placing the card in the IC reader.

  19. Systemic changes and adverse effects induced by retinopathy of prematurity screening.

    Science.gov (United States)

    Jiang, Jing-Bo; Zhang, Zhi-Wei; Zhang, Jia-Wen; Wang, Yan-Li; Nie, Chuan; Luo, Xian-Qiong

    2016-01-01

    To estimate the potential systemic events during and after retinopathy of prematurity (ROP) screening. A prospective and descriptive designed study was conducted to detect the physiologic and pathological changes 24h before, during, and 72h after ROP screening. Control blood pressure (BP), saturation, pulse rate, and body temperature were routinely taken at various time internals before and after screening. Adverse effects pertain to cardiovascular system, respiratory system, gastric system, urinary system and nervous system were retrospect 0-72h after ROP screening at a 24-hour interval. Totally 1254 prematurity babies receiving ROP screening during Jan. 1(st) 2013 to Dec. 31(th) 2013 were enrolled in our survey. Compared to control vital sign data taken before the examination, there was a fluctuation in the diastolic BP with the increased 3.03 mm Hg (P=0.04) after 3 doses of mydriatic drops. Immediately after the examination, there was a further 12.64 mm Hg (Pprematurity with postconceptional age less than 31wk, the incidence of apnea (23.5%), necrotizing enterocolitis (NEC) (8.7%), gastric residual (25.4%) and upper digestive tract hemorrhage (6.4%) also demonstrated a significant rise (P<0.01). In our study sample, ROP screening was associated with NEC, gastric residual and upper digestive tract hemorrhage. These gastrointestinal side effects, along with breath activity pattern change and vital signs indicators fluctuation, may be results of additional stress responses.

  20. Evaluation of an automated connective tissue disease screening assay in Korean patients with systemic rheumatic diseases.

    Science.gov (United States)

    Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong

    2017-01-01

    This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE.

  1. Evaluation of an automated connective tissue disease screening assay in Korean patients with systemic rheumatic diseases.

    Directory of Open Access Journals (Sweden)

    Seri Jeong

    Full Text Available This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA, systemic lupus erythematosus (SLE, and mixed connective tissue disease (MCT. The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6, including SLE (24.3 vs. 10.7. The areas under the receiver operating characteristic curves (ROC-AUCs of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72 and MCT (0.85 than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE.

  2. N-screen aware multicriteria hybrid recommender system using weight based subspace clustering.

    Science.gov (United States)

    Ullah, Farman; Sarwar, Ghulam; Lee, Sungchang

    2014-01-01

    This paper presents a recommender system for N-screen services in which users have multiple devices with different capabilities. In N-screen services, a user can use various devices in different locations and time and can change a device while the service is running. N-screen aware recommendation seeks to improve the user experience with recommended content by considering the user N-screen device attributes such as screen resolution, media codec, remaining battery time, and access network and the user temporal usage pattern information that are not considered in existing recommender systems. For N-screen aware recommendation support, this work introduces a user device profile collaboration agent, manager, and N-screen control server to acquire and manage the user N-screen devices profile. Furthermore, a multicriteria hybrid framework is suggested that incorporates the N-screen devices information with user preferences and demographics. In addition, we propose an individual feature and subspace weight based clustering (IFSWC) to assign different weights to each subspace and each feature within a subspace in the hybrid framework. The proposed system improves the accuracy, precision, scalability, sparsity, and cold start issues. The simulation results demonstrate the effectiveness and prove the aforementioned statements.

  3. Controlled single-blind clinical evaluation of low-dose mammographic screen: film systems

    International Nuclear Information System (INIS)

    Sickles, E.A.; Genant, H.K.

    1979-01-01

    The ability of five low-dose mammographic screen-film systems to portray normal and abnormal breast structures was evaluated in parallel with a study of physical image properties. Single-blind evaluations of the visibility of normal breast architecture, mass lesions, and calcifications were made on the mammograms of 100 patients radiographed with each of the systems. There was increased noise and slightly poorer resolution of the faster recording systems, but there was no difference in final diagnostic impressions among the five systems. These results suggest that the faster systems will result in substantial dose reduction without sacrificing diagnostic accuracy

  4. Intelligent Screening Systems for Cervical Cancer

    Directory of Open Access Journals (Sweden)

    Yessi Jusman

    2014-01-01

    Full Text Available Advent of medical image digitalization leads to image processing and computer-aided diagnosis systems in numerous clinical applications. These technologies could be used to automatically diagnose patient or serve as second opinion to pathologists. This paper briefly reviews cervical screening techniques, advantages, and disadvantages. The digital data of the screening techniques are used as data for the computer screening system as replaced in the expert analysis. Four stages of the computer system are enhancement, features extraction, feature selection, and classification reviewed in detail. The computer system based on cytology data and electromagnetic spectra data achieved better accuracy than other data.

  5. Psychosocial consequences of allocation to lung cancer screening: a randomised controlled trial.

    Science.gov (United States)

    Aggestrup, Louise Mosborg; Hestbech, Mie Sara; Siersma, Volkert; Pedersen, Jesper Holst; Brodersen, John

    2012-01-01

    To examine the psychosocial consequences of being allocated to the control group as compared with the screen group in a randomised lung cancer screening trial. The Danish Lung Cancer Screening Trial, a randomised controlled trial, ran from 2004 to 2010 with the purpose of investigating the benefits and harms of lung cancer screening. The participants in Danish Lung Cancer Screening Trial were randomised to either the control group or the screen group and were asked to complete the questionnaires Consequences Of Screening and Consequences Of Screening in Lung Cancer (COS-LC). The Consequences Of Screening and the COS-LC were used to examine the psychosocial consequences of participating in the study, by comparing the control and the screen groups' responses at the prevalence and at the incidence round. There was no statistically significant difference in socio-demographic characteristics or smoking habits between the two groups. Responses to the COS-LC collected before the incidence round were statistically significantly different on the scales 'anxiety', 'behaviour', 'dejection', 'self-blame', 'focus on airway symptoms' and 'introvert', with the control group reporting higher negative psychosocial consequences. Furthermore, the participants in both the control and the screen groups exhibited a mean increase in negative psychosocial consequences when their responses from the prevalence round were compared with their responses from the first incidence round. Participation in a randomised controlled trial on lung cancer screening has negative psychosocial consequences for the apparently healthy participants-both the participants in the screen group and the control group. This negative impact was greatest for the control group.

  6. Energy saving in greenhouses can be obtained by energy balance-controlled screens

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, N. E. (Univ. of Aarhus, Faculty of Agricultural Sciences, Dept. of Horticulture, Aarslev (Denmark)), e-mail: niels.andersson@agrsci.dk

    2011-03-15

    The energy screens in two greenhouses, one clad with double acrylic and one with single glass, were controlled by an energy balance model. The parameters in the model were heat transmission coefficients, air temperature in the greenhouse and outdoors, irradiance and a single constant for the solar energy efficiency. The energy consumption, screen movements and daily light integral were compared with a glass greenhouse in which the energy screens were controlled by irradiance. In the greenhouse with light-controlled screens the set point for opening and closing of the screens was 5 Wm-2. The energy-saving screens controlled by the energy balance model opened later and closed earlier than in the greenhouse with light-controlled screens. When using the energy balance model the energy saving was 14% for the glass greenhouse and 41% for the double acrylic greenhouse compared with the glass greenhouse with light-controlled screens. The air temperature was on average similar in the three greenhouses, but when the screens were controlled by energy balance the daily light integral was approximately 10% lower and the number of hours the screens were closed was prolonged with 35% for the glass-covered greenhouse and 25% for the double acrylic-covered greenhouse compared with the greenhouse with light-controlled screens. Energy peaks in connection with operation of the screens were not reduced. During the experiment Begonia elatior, Dendranthema grandiflora (Chrysanthemum), Hedera helix, Helianthus annuus, Gerbera jamesonii and Kalanchoe blossfeldiana were grown in the greenhouses. There was a trend in prolongation of the production time when the plants were grown in the glass greenhouse with energy balance control of the screens. A lower number of flowers or inflorescences were observed for some of the plant species produced in the greenhouses with energy balance-controlled screens

  7. Microfluidic Devices for Drug Delivery Systems and Drug Screening

    Science.gov (United States)

    Kompella, Uday B.; Damiati, Safa A.

    2018-01-01

    Microfluidic devices present unique advantages for the development of efficient drug carrier particles, cell-free protein synthesis systems, and rapid techniques for direct drug screening. Compared to bulk methods, by efficiently controlling the geometries of the fabricated chip and the flow rates of multiphase fluids, microfluidic technology enables the generation of highly stable, uniform, monodispersed particles with higher encapsulation efficiency. Since the existing preclinical models are inefficient drug screens for predicting clinical outcomes, microfluidic platforms might offer a more rapid and cost-effective alternative. Compared to 2D cell culture systems and in vivo animal models, microfluidic 3D platforms mimic the in vivo cell systems in a simple, inexpensive manner, which allows high throughput and multiplexed drug screening at the cell, organ, and whole-body levels. In this review, the generation of appropriate drug or gene carriers including different particle types using different configurations of microfluidic devices is highlighted. Additionally, this paper discusses the emergence of fabricated microfluidic cell-free protein synthesis systems for potential use at point of care as well as cell-, organ-, and human-on-a-chip models as smart, sensitive, and reproducible platforms, allowing the investigation of the effects of drugs under conditions imitating the biological system. PMID:29462948

  8. Sensitivity of screen-film systems

    International Nuclear Information System (INIS)

    Sandborg, M.; Nilsson, Goergen; Holje, G.

    1992-01-01

    This report, which has been funded by SSI, presents sensitivity data on the 'second generation' of modern intensifying screens, commercially available at the onset of the investigation. The sensitivity of the screen-film systems was evaluated with 80 kV tube potential and a total filtration of 3.0 mm Al. 20 mm aluminum was used for simulating human tissue, since it gives the same HVL x , as does 25 cm water. Kerma in air, needed to produce a net film density of 1.00 was determined and its inverse, expressed in mGy -1 , was taken as an indicator of the sensitivity; here called the sensitivity class of a screen-film system

  9. A System Dynamics Model of Serum Prostate-Specific Antigen Screening for Prostate Cancer.

    Science.gov (United States)

    Palma, Anton; Lounsbury, David W; Schlecht, Nicolas F; Agalliu, Ilir

    2016-02-01

    Since 2012, US guidelines have recommended against prostate-specific antigen (PSA) screening for prostate cancer. However, evidence of screening benefit from the Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening trial and the European Randomized Study of Screening for Prostate Cancer has been inconsistent, due partly to differences in noncompliance and contamination. Using system dynamics modeling, we replicated the PLCO trial and extrapolated follow-up to 20 years. We then simulated 3 scenarios correcting for contamination in the PLCO control arm using Surveillance, Epidemiology, and End Results (SEER) incidence and survival data collected prior to the PSA screening era (scenario 1), SEER data collected during the PLCO trial period (1993-2001) (scenario 2), and data from the European trial's control arm (1991-2005) (scenario 3). In all scenarios, noncompliance was corrected using incidence and survival rates for men with screen-detected cancer in the PLCO screening arm. Scenarios 1 and 3 showed a benefit of PSA screening, with relative risks of 0.62 (95% confidence interval: 0.53, 0.72) and 0.70 (95% confidence interval: 0.59, 0.83) for cancer-specific mortality after 20 years, respectively. In scenario 2, however, there was no benefit of screening. This simulation showed that after correcting for noncompliance and contamination, there is potential benefit of PSA screening in reducing prostate cancer mortality. It also demonstrates the utility of system dynamics modeling for synthesizing epidemiologic evidence to inform public policy. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Control system oriented human interface

    International Nuclear Information System (INIS)

    Barale, P.; Jacobson, V.; Kilgore, R.; Rondeau, D.

    1976-11-01

    The on-line control system interface for magnet beam steering and focusing in the Bevalac is described. An Aydin model 5205B display generator was chosen. This display generator will allow the computer to completely rewrite a monitor screen in less than 50 ms and is also capable of controlling a color monitor

  11. Screening candidate systems engineers: a research design

    CSIR Research Space (South Africa)

    Goncalves, DP

    2009-07-01

    Full Text Available engineering screening methodology that could be used to screen potential systems engineers. According to their design, this can be achieved by defining a system engineering profile according to specific psychological attributes, and using this profile...

  12. Analysis of sustainable pest control using a pesticide and a screened refuge.

    Science.gov (United States)

    Ringland, John; George, Prasanth

    2011-05-01

    We describe and analyze a 'screened refuge' technique for indefinitely sustaining control of insect pests using transgenic pesticidal crops or an applied pesticide, even when resistance is not recessive. The screen is a physical barrier that restricts pest movement. In a deterministic discrete-time model of the use of this technique, we obtain asymptotic analytical formulas for the two important equilibria of the system in terms of the refuge size and the pest fitnesses, mutation rates, and mobility out of and into the refuge. One of the equilibria is stable and is the point at which the pest population is controlled. The other is a saddle whose stable manifold bounds the basin of attraction of the former: its location provides a measure of the tolerance of the control mechanism to perturbations in the resistant allele density.

  13. Mechanical evaluation of a new sand control screen for SAGD applications

    Energy Technology Data Exchange (ETDEWEB)

    Woiceshyn, G. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Absolute Completion Technologies, Calgary, AB (Canada); Toffanin, E. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Schlumberger Canada Ltd., Calgary, AB (Canada); Xie, J.; Wagg, B. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[C-FER Technologies, Edmonton, AB (Canada); Fan, C. [C-FER Technologies, Edmonton, AB (Canada)

    2008-10-15

    Steam assisted gravity drainage (SAGD) wells normally require the deployment of an open hole completion combining sand control with adequate mechanical strength to withstand aggressive installation loads and serve operational loads. Slotted liners have traditionally been used in western Canada, mainly because of low cost relative to wire-wrapped screen or premium mesh screens. However, slotting base pipe can weaken the mechanical strength. The slot width can also change as the liner deforms under certain load conditions. Operators are therefore interested in alternative technologies to reduce incidents of mechanical failure and loss of sand control of slotted liners in SAGD wells. This paper presented the flush absolute cartridge system (FACS), a newly developed sand screen onto which a 25.4 diameter fusion bonded metal laminate cartridge is directly mounted and secured directly into the base pipe wall. The paper discussed a finite element analysis study that was conducted in order to independently quantify its mechanical strength and integrity for use in SAGD operations. The paper described the liner, as well as the disc geometry, construction and properties. The paper also listed the potential applications for FACS screens and provided a description of the finite element analysis. It was concluded that although FACS satisfies the basic operational criteria, it has very limited ability to absorb additional strain at the end of the thermal cycle. 10 refs., 4 tabs., 22 figs.

  14. Development and applicability of a ready-to-use PCR system for GMO screening.

    Science.gov (United States)

    Rosa, Sabrina F; Gatto, Francesco; Angers-Loustau, Alexandre; Petrillo, Mauro; Kreysa, Joachim; Querci, Maddalena

    2016-06-15

    With the growing number of GMOs introduced to the market, testing laboratories have seen their workload increase significantly. Ready-to-use multi-target PCR-based detection systems, such as pre-spotted plates (PSP), reduce analysis time while increasing capacity. This paper describes the development and applicability to GMO testing of a screening strategy involving a PSP and its associated web-based Decision Support System. The screening PSP was developed to detect all GMOs authorized in the EU in one single PCR experiment, through the combination of 16 validated assays. The screening strategy was successfully challenged in a wide inter-laboratory study on real-life food/feed samples. The positive outcome of this study could result in the adoption of a PSP screening strategy across the EU; a step that would increase harmonization and quality of GMO testing in the EU. Furthermore, this system could represent a model for other official control areas where high-throughput DNA-based detection systems are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Influence of platform screen doors on energy consumption of the environment control system of a mass rapid transit system: case study of the Taipei MRT system

    Energy Technology Data Exchange (ETDEWEB)

    Hu, S.-C. E-mail: f10870@ntut.edu.tw; Lee, J.-H

    2004-03-01

    This investigation studies how platform screen doors (PSD) affect the energy consumption of the environmental control system of a mass rapid transit (MRT) system in Taipei. The environmental parameter simulation was conducted using the subway environmental simulation (SES) program, while the associated air conditioning (A/C) cooling load was predicted with the carrier E20-II program. Results show that PSD can significantly decrease average and peak cooling load, thus reducing the capacity/size of cooling equipment and allowing the chiller cooling load to be abridged. However, electricity consumption by ventilation equipment increases notably when PSD are used, particularly the electricity consumption by the under platform exhaust (UPE) fan, and thus, ultimately, little difference exists in the overall energy consumption with and without UPE.

  16. Influence of platform screen doors on energy consumption of the environment control system of a mass rapid transit system: case study of the Taipei MRT system

    International Nuclear Information System (INIS)

    Hu, S.-C.; Lee, J.-H.

    2004-01-01

    This investigation studies how platform screen doors (PSD) affect the energy consumption of the environmental control system of a mass rapid transit (MRT) system in Taipei. The environmental parameter simulation was conducted using the subway environmental simulation (SES) program, while the associated air conditioning (A/C) cooling load was predicted with the carrier E20-II program. Results show that PSD can significantly decrease average and peak cooling load, thus reducing the capacity/size of cooling equipment and allowing the chiller cooling load to be abridged. However, electricity consumption by ventilation equipment increases notably when PSD are used, particularly the electricity consumption by the under platform exhaust (UPE) fan, and thus, ultimately, little difference exists in the overall energy consumption with and without UPE

  17. What makes a control system usable? An operational viewpoint

    International Nuclear Information System (INIS)

    Clay, M.

    1990-01-01

    This report discusses the generally accepted successes and shortcomings of the various computer and hardware-based control systems at the Los Alamos Meson Physics Facility (LAMPF) from an operator's standpoint. LAMPF currently utilizes three separate control rooms that, although critically co-dependent, use distinct operating methods. The first, the Injector Control Room, which is responsible for the operation of the three ion sources, the 750 keV transport lines and the 201.25 MHz portion of the linac, uses a predominantly hardware-based control system. The second, the LANSCE Control Room, which is responsible for the operation of the Los Alamos Neutron Scattering Center, uses a graphical touch-panel interface with single-application screens as its control system. The third, the LAMPF Central Control Room, which is responsible for the overall operation of LAMPF, primarily uses a text-oriented keyboard interface with multiple applications per screen. Though each system provides generally reliable human interfacing to the enormously complex and diverse machine known as LAMPF, the operational requirements of speed, usability, and reliability are increasingly necessitating the use of a standard control system that incorporates the positive aspects of all three control systems. (orig.)

  18. New generation expandable sand screens

    OpenAIRE

    Syltøy, Christer

    2014-01-01

    Master's thesis in Petroleum engineering This thesis aims to give a general insight into sand control and various sorts of sand control measures and applications of sand control tools. Special focus will be given to expandable sand screens – a technology which came about in the late 1990’s through the use of flexible, expandable tubulars as base pipe in sand screens. More specifically Darcy’s Hydraulic Endurance Screens, a compliant sand screen system using hydraulic activation, and the fu...

  19. Design, construction and commissioning of the Thermal Screen Control System for the CMS Tracker detector at CERN

    CERN Document Server

    Carrone, E; Tsirou, A

    The CERN (European Organization for Nuclear Research) laboratory is currently building the Large Hadron Collider (LHC). Four international collaborations have designed (and are now constructing) detectors able to exploit the physics potential of this collider. Among them is the Compact Muon Solenoid (CMS), a general purpose detector optimized for the search of Higgs boson and for physics beyond the Standard Model of fundamental interactions between elementary particles. This thesis presents, in particular, the design, construction, commissioning and test of the control system for a screen that provides a thermal separation between the Tracker and ECAL (Electromagnetic CALorimeter) detector of CMS (Compact Muon Solenoid experiment). Chapter 1 introduces the new challenges posed by these installations and deals, more in detail, with the Tracker detector of CMS. The size of current experiments for high energy physics is comparable to that of a small industrial plant: therefore, the techniques used for controls a...

  20. Hand held control unit for controlling a display screen-oriented computer game, and a display screen-oriented computer game having one or more such control units

    NARCIS (Netherlands)

    2001-01-01

    A hand-held control unit is used to control a display screen-oriented computer game. The unit comprises a housing with a front side, a set of control members lying generally flush with the front side for through actuating thereof controlling actions of in-game display items, and an output for

  1. Pointright: a system to redirect mouse and keyboard control among multiple machines

    Science.gov (United States)

    Johanson, Bradley E [Palo Alto, CA; Winograd, Terry A [Stanford, CA; Hutchins, Gregory M [Mountain View, CA

    2008-09-30

    The present invention provides a software system, PointRight, that allows for smooth and effortless control of pointing and input devices among multiple displays. With PointRight, a single free-floating mouse and keyboard can be used to control multiple screens. When the cursor reaches the edge of a screen it seamlessly moves to the adjacent screen and keyboard control is simultaneously redirected to the appropriate machine. Laptops may also redirect their keyboard and pointing device, and multiple pointers are supported simultaneously. The system automatically reconfigures itself as displays go on, go off, or change the machine they display.

  2. NPL superconducting Linac control system

    International Nuclear Information System (INIS)

    Swanson, H.E.; Howe, M.A.; Jackson, L.W.; LaCroix, J.M.; Readdy, H.P.; Storm, D.W.; Van Houten, L.P.

    1985-01-01

    The control system for the NPL Linac is based on a Microvax II host computer connected in a star network with 9 satellite computers. These satellites use single board varsions of DEC's PDP 11 processor. The operator's console uses high performance graphics and touch screen technology to display the current linac status and as the means for interactively controlling the operation of the accelerator

  3. Design of Screens for Sand Control of Wells

    Directory of Open Access Journals (Sweden)

    Ján Pinka

    2006-04-01

    Full Text Available Drilling, completion, production, and reservoir engineers, supervisors, foremen, superintendents, service company personnel, technologists and anyone involved with recommending, selecting, designing or on-site performance of well completions or workovers where sand production is, or may become, a serious problem will benefit from this course. Less sand influx can be expected in a horizontal well than in a vertical well. If horizontal holes in weak formation sands can be successfully gravel packed, the result could be significantly higher well productivity than with a liner, screen or pre-packed screen alone. The article covers innovative screens for sand control used in oil and gas industry from the world leaders in total completion. The type of screen (wire wrapped, reinforced, pre-packed, ect. should also be chosen with due consideration to running-in condition (curve radius, compression when the screens are pushed along the drain hole, etc..

  4. Work index determination with changing of control screen

    International Nuclear Information System (INIS)

    Noaparast, M.; Delavarian, M.

    2001-01-01

    Work index is a measure to define ores/minerals grind ability which is significantly used in Bond (1952) to calculate the required energy of ores' comminution. Work index for any material is experimentally calculated under specific conditions and it is a certain value. To understand the effect of changing control screen in work index calculation, three different ores Alam-Kuh Pb-Zn ore, Sarcheshmeh Cu Ore, and Abe-Garm Region Dolomite were tested, using 425, 212,150 and 100 micron screens (totally 12 sets of tests). Results showed that the work index values increase with the increases of screen size. The relation between root of screen size and fines produced per revolution of mill and also, screen size and size of products out of which 80% passes through this size appeared to be linear for all three different ores. The constants of these linear equations were estimated using regression technique

  5. Automated and Clinical Breast Imaging Reporting and Data System Density Measures Predict Risk for Screen-Detected and Interval Cancers: A Case-Control Study.

    Science.gov (United States)

    Kerlikowske, Karla; Scott, Christopher G; Mahmoudzadeh, Amir P; Ma, Lin; Winham, Stacey; Jensen, Matthew R; Wu, Fang Fang; Malkov, Serghei; Pankratz, V Shane; Cummings, Steven R; Shepherd, John A; Brandt, Kathleen R; Miglioretti, Diana L; Vachon, Celine M

    2018-06-05

    In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead. To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures. Case-control. San Francisco Mammography Registry and Mayo Clinic. 1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants. Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity. Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screen-detected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively. Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method. Automated and clinical BI

  6. High intensification screen-film systems in thorax radiography: a clinical comparison

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Sokiranski, R.; Claussen, C.D.

    1995-01-01

    Objective: The quality of chest images was evaluated for a conventional screen-film system, a new asymmetric screen-film system, and a new uv screen-film system. Materials and Methods: 138 Chest radiographs (69 p.a., 69 lateral) obtained with three different high intensification screen-film combinations were compared. Film density and film contrast were measured. Three readers graded the image quality according to 16 criteria. Results: The asymmetric film-screen combination Insight HC showed the lowest film contrast, the best exposure range, and a elevated film density in the mediastinal area. The asymmetric screen-film system was ranked by all three observers as being substantially better in image quality. Conclusion: Compared to conventional screen-film systems, the new screen-film systems can improve the image quality of chest radiographs. Therefore, the new high intensification screen-film combinations can be used as a low cost alternative to the Amber technique and digital radiography. (orig.) [de

  7. Noise of screen-film systems: origins and components

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, H

    1983-01-01

    When using the more sensitive rare-earth intensifying screens in radiography applying the screen-film system, one has to cope with an increase in quantum noise. Measurement of Wiener spectra will help to determine the noise of the film. With an appropriate apparatus, the noise spectra of screen-film systems of different sensitivity have been ascertained and compared with theoretical assessments. The integral noise made up of the components film noise, screen noise and quantum noise have been thoroughly analysed. Adequate choice of radiographic conditions (such as modification of film exposure time via the screen, change of tube voltage) will affect the number of absorbed X-ray quanta in the luminous substance and thus the quantum noise which, as was found out, largely contributes to the integral noise together with another factor, graininess of the film. The study shows that although quantum noise has to be cut back, this should not be done at any price, and due regard must be paid to other factors influencing the image quality of the system, such as contrast and MTF.

  8. Design of monitoring and control system of digital power supply for HIMM based on microcontroller

    International Nuclear Information System (INIS)

    Yu Chunlei; Wu Fengjun; Gao Daqing; Yan Huaihai; Chen Youxin; Guo Yuxin; Huang Yuzhen; Zhang Huajian

    2013-01-01

    The touch screen control system is under development in Heavy Ion Medical Machine (HIMM) project. In this paper, the touch screen control system is studied in detail, which is driven by PIC24 microcontroller. According to the internal protocol of power system , control of power switch , waveform and state display, parameter setting are all implemented in this control system. The communication among microcontroller, FPGA board for power supply and state board is normal and stable during the test. Compared to analog switch control system, the local control system for HIMM is much more convenient and aesthetic, additionally the control accuracy is even higher. (authors)

  9. Psychosocial consequences in the Danish randomised controlled lung cancer screening trial (DLCST).

    Science.gov (United States)

    Rasmussen, Jakob F; Siersma, V; Pedersen, J H; Brodersen, J

    2015-01-01

    To measure the psychosocial consequences in the Danish lung cancer screening trial (DLCST) and compare those between the computed tomography (CT) group and the control group. This study was a single centre randomised controlled trial with five annual screening rounds. Healthy current or former heavy smokers aged 50-70 years (men and women) were randomised 1:1 to a CT group and a control group. Heavy smokers were defined by having smoked ≥20 pack years and former smokers by being abstinent ≤10 years. Both groups were invited annually to the screening clinic to complete the validated lung-cancer-specific questionnaire consequences of screening lung cancer (COS-LC). The CT group was also offered a low dose CT scan of the lungs. The COS-LC measures nine scales with psychosocial properties: Anxiety, Behaviour, Dejection, Negative impact on sleep, Self-blame, Focus on Airway Symptoms, Stigmatisation, Introvert, and Harm of Smoking. 4104 participants were randomised to the DLCST and the COS-LC completion rates for the CT group and the control group were 95.5% and 73.6%, respectively. There was a significant increase in negative psychosocial consequences from baseline through rounds 2-5 for both the CT group and the control group (mean increase >0, p0 and p<.033). Lung cancer CT-screening trials induced more negative psychosocial reactions in both the CT group and the control group compared with the baseline psychosocial profile. The CT group experienced less negative psychosocial consequences compared with the control group, which might be explained by reassurance among those with normal screening results. ClinicalTrials.gov: NCT00496977. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Qualitative vs. quantitative data: Controls on the accuracy of PID field screening in petroleum contamination assessment applications

    International Nuclear Information System (INIS)

    Luessen, M.J.; Allex, M.K.; Holzel, F.R.

    1995-01-01

    The use of photoionization detectors (PIDs) for field screening of soils for volatile organic contaminants has become a standard industry practice. PID screening data is generally utilized as a qualitative basis for selection of samples for laboratory analysis to quantify concentrations of specific contaminants of concern. Both qualitative field screening data and quantitative laboratory analytical data were reviewed for more than 100 hydrogeologic assessment sites in Ohio to evaluate controls on the effectiveness of field screening data. Assessment data evaluated was limited to sites at which the suspected contaminant source was a gasoline underground storage tanks system. In each case, a 10.0 eV (or greater) PID calibrated for benzene was used to screen soils which were analyzed for benzene, toluene, ethylbenzene and xylene (BTEX) by SW 846 method 8020. Controls on field screening which were evaluated for each site included (1) soil classification, (2) soil moisture, (3) weather conditions, (4) background levels, (5) equipment quality, (6) screening methodology, and (7) laboratory QA/QC. Statistical data analysis predictably indicated a general overestimate of total BTEX levels based on field screening (gasoline is approximately 25 weight percent BTEX). However, data locally indicated cases of both significant (i.e., more than an order of magnitude difference) over- and under-estimation of actual BTEX concentrations (i.e., quantitative laboratory data) by field screening data

  11. Quality control in screening programs for cervical cancer

    International Nuclear Information System (INIS)

    Sarduy Napoles, Miguel

    2012-01-01

    The malignancy of the cervix is one of the few locations avoidable cancers, if detected before it progresses to the infiltration. The most efficient way of early detection is through a screening program to provide women undertaking a regular and quality Pap smear. If this test results abnormal, the program offers easier access to specialized care, effective treatment, and follow-up. The objective of this article is to present usefulness of methods for quality control used in screening programs for cervical cancer to detect their inadequacies. Here are some factors and conditions that must be considered in each of the steps to take, for a cervical cancer screening program to be successful and to meet the objectives proposed in reducing mortality due to this cause. This document contains some useful indexes calculated to ensure quality throughout the process. There should be the measurement of quality throughout the screening process that allows collecting of reliable data as well as correcting deficiencies

  12. Prostate Cancer Screening Efficacy in African-Americans Using Case-Control Methodology

    National Research Council Canada - National Science Library

    Godley, Paul

    1999-01-01

    ...-control study of PSA screening for prostate cancer in African Americans. The lack of symptoms documented in the patient's medical record was to be used as evidence that PSA was intended as a screening examination...

  13. Influence of platform screen doors on energy consumption of the environment control system of a mass rapid transit system: case study of the Taipei MRT [mass rapid transit] system

    Energy Technology Data Exchange (ETDEWEB)

    Shih-Cheng Hu; Jen-Ho Lee [National Taipei University of Technology, Taipei (China). Dept. of Air Conditioning and Refrigeration Engineering

    2004-03-01

    This investigation studies how platform screen doors (PSD) affect the energy consumption of the environmental control system of a mass rapid transit (MRT) system in Taipei. The environmental parameter simulation was conducted using the subway environmental simulation (SES) program, while the associated air conditioning (A/C) cooling load was predicted with the carrier E20-II program. Results show that PSD can significantly decrease average and peak cooling load, thus reducing the capacity/size of cooling equipment and allowing the chiller cooling load to be abridged. However, electricity consumption by ventilation equipment increases notably when PSD are used, particularly the electricity consumption by the under platform exhaust (UPE) fan, and thus, ultimately, little difference exists in the overall energy consumption with and without UPE. (author)

  14. The relative and absolute speed of radiographic screen - film systems

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon

    1993-01-01

    Recently, a large number of new screen-film systems have become available for use in diagnostic radiology. These new screens are made of materials generally known as rare - earth phosphors which have high x-ray absorption and high x-ray to light conversion efficiency compared to calcium tungstate phosphors. The major advantage of these new systems is reduction of patient exposure due to their high speed or high sensitivity. However, a system with excessively high speed can result in a significant degradation of radiographic image quality. Therefore, the speed is important parameters for users of these system. Our aim of in this was to determine accurately and precisely the absolute speed and relative speeds of both new and conventional screen - film system. We determined the absolute speed in condition of BRH phantom beam quality and the relative speed were measured by a split - screen technique in condition of BRH and ANSI phantom beam quality. The absolute and the relative speed were determined for 8 kinds of screen - 4 kinds of film in regular system and 7 kinds pf screen - 7 kinds of film in ortho system. In this study we could know the New Rx, T - MAT G has the highest film speed, also know Green system's standard deviation of relative speed larger than blue system. It was realized that there were no relationship between the absolute speed and the blue system. It was realized that there were no relationship between the absolute speed and the relative speed in ortho or regular system

  15. A Decision Aid to Promote Appropriate Colorectal Cancer Screening among Older Adults: A Randomized Controlled Trial.

    Science.gov (United States)

    Lewis, Carmen L; Kistler, Christine E; Dalton, Alexandra F; Morris, Carolyn; Ferrari, Renée; Barclay, Colleen; Brewer, Noel T; Dolor, Rowena; Harris, Russell; Vu, Maihan; Golin, Carol E

    2018-07-01

    Concerns have been raised about both over- and underutilization of colorectal cancer (CRC) screening in older patients and the need to align screening behavior with likelihood of net benefit. The purpose of this study was to test a novel use of a patient decision aid (PtDA) to promote appropriate CRC screening in older adults. A total of 424 patients ages 70 to 84 y who were not up to date with CRC screening participated in a double-blinded randomized controlled trial of a PtDA targeted to older adults making decisions about whether to undergo CRC screening from March 2012 to February 2015. Patients were randomized to a targeted PtDA or an attention control. The PtDA was designed to facilitate individualized decision making-helping patients understand the potential risks, benefits, and uncertainties of CRC screening given advanced age, health state, preferences, and values. Two composite outcomes, appropriate CRC screening behavior 6 mo after the index visit and appropriate screening intent immediately after the visit, were defined as completed screening or intent for patients in good health, discussion about screening with their provider for patients in intermediate health, and no screening or intent for patients in poor health. Health state was determined by age and Charlson Comorbidity Index. Four hundred twelve (97%) and 421 (99%) patients were analyzed for the primary and secondary outcomes, respectively. Appropriate screening behavior at 6 mo was higher in the intervention group (55% v. 45%, P = 0.023) as was appropriate screening intent following the provider visit (61% v. 47%, P = 0.003). The study took place in a single geographic region. The appropriate CRC screening classification system used in this study has not been formally validated. A PtDA for older adults promoted appropriate CRC screening behavior and intent. Clinicaltrials.gov, registration number NCT01575990. https://clinicaltrials.gov/ct2/show/NCT01575990?term=epic-d&rank=1.

  16. Iterative Cellular Screening System for Nanoparticle Safety Testing

    Directory of Open Access Journals (Sweden)

    Franziska Sambale

    2015-01-01

    Full Text Available Nanoparticles have the potential to exhibit risks to human beings and to the environment; due to the wide applications of nanoproducts, extensive risk management must not be neglected. Therefore, we have constructed a cell-based, iterative screening system to examine a variety of nanoproducts concerning their toxicity during development. The sensitivity and application of various cell-based methods were discussed and proven by applying the screening to two different nanoparticles: zinc oxide and titanium dioxide nanoparticles. They were used as benchmarks to set up our methods and to examine their effects on mammalian cell lines. Different biological processes such as cell viability, gene expression of interleukin-8 and heat shock protein 70, as well as morphology changes were investigated. Within our screening system, both nanoparticle suspensions and coatings can be tested. Electric cell impedance measurements revealed to be a good method for online monitoring of cellular behavior. The implementation of three-dimensional cell culture is essential to better mimic in vivo conditions. In conclusion, our screening system is highly efficient, cost minimizing, and reduces the need for animal studies.

  17. Quality control for the mammography screening program in Serbia: Physical and technical aspects

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Bozovic, P.; Lazarevic, D.; Arandjic, D.; Kosutic, D.

    2012-01-01

    Breast cancer is the major cause of mortality among female population in Serbia. It is presumed that the introduction of screening programme will reduce mortality and therefore, 47 new mammography units were installed for the purpose of population-based screening program in 2011. In parallel, Quality assurance and Quality control (QC) in mammography has received increasing attention as an essential element of the successful breast cancer campaign that is for the first time initialed in Serbia. The purpose of this study is to investigate the need for and the possible implementation of the comprehensive QC programme for the mammography screening in Serbia, with special focus on physical and technical aspect. In the first phase, a QC protocols containing list of parameters, methodology, frequency of tests and reference values for screen-film, computed radiography and full-filed digital mammography) units, were developed. The second phase is focused on the initial implementation of these protocols. The paper presents results of tests of the selected parameters in 35 mammography units, with special emphasis on patient dose and image quality descriptors. After initial implementation at the beginning of the population based breast cancer screening campaign, it is essential to establish system of regular and periodic QC equipment monitoring and to ensure high quality mammograms with minimal possible radiation dose to population included in the screening. (authors)

  18. Method for screening prevention and control measures and technologies based on groundwater pollution intensity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Li, Juan, E-mail: lijuan@craes.org.cn [College of Water Sciences, Beijing Normal University, Beijing 100875 (China); Chinese Research Academy of Environmental Sciences, Beijing 100012 (China); State Environmental Protection Key Laboratory of Simulation and Control of Groundwater Pollution, Beijing, 100012 (China); Yang, Yang [College of Environment, Beijing Normal University, Beijing 100875 (China); Chinese Research Academy of Environmental Sciences, Beijing 100012 (China); State Environmental Protection Key Laboratory of Simulation and Control of Groundwater Pollution, Beijing, 100012 (China); Huan, Huan; Li, Mingxiao [Chinese Research Academy of Environmental Sciences, Beijing 100012 (China); State Environmental Protection Key Laboratory of Simulation and Control of Groundwater Pollution, Beijing, 100012 (China); Xi, Beidou, E-mail: xibd413@yeah.net [Chinese Research Academy of Environmental Sciences, Beijing 100012 (China); State Environmental Protection Key Laboratory of Simulation and Control of Groundwater Pollution, Beijing, 100012 (China); Lanzhou Jiaotong University, Lanzhou 730070 (China); Lv, Ningqing [Chinese Research Academy of Environmental Sciences, Beijing 100012 (China); State Environmental Protection Key Laboratory of Simulation and Control of Groundwater Pollution, Beijing, 100012 (China); Wu, Yi [Guizhou Academy of Environmental Science and Designing, Guizhou 550000 (China); Xie, Yiwen, E-mail: qin3201@126.com [School of Chemical and Environmental Engineering, Dongguan University of Technology, Dongguan, 523808 (China); Li, Xiang; Yang, Jinjin [Chinese Research Academy of Environmental Sciences, Beijing 100012 (China); State Environmental Protection Key Laboratory of Simulation and Control of Groundwater Pollution, Beijing, 100012 (China)

    2016-05-01

    This paper presents a system for determining the evaluation and gradation indices of groundwater pollution intensity (GPI). Considering the characteristics of the vadose zone and pollution sources, the system decides which anti-seepage measures should be implemented at the contaminated site. The pollution sources hazards (PSH) and groundwater intrinsic vulnerability (GIV) are graded by the revised Nemerow Pollution Index and an improved DRTAS model, respectively. GPI is evaluated and graded by a double-sided multi-factor coupling model, which is constructed by the matrix method. The contaminated sites are categorized as prior, ordinary, or common sites. From the GPI results, we develop guiding principles for preventing and removing pollution sources, procedural interruption and remediation, and end treatment and monitoring. Thus, we can select appropriate prevention and control technologies (PCT). To screen the technological schemes and optimize the traditional analytical hierarchy process (AHP), we adopt the technique for order preference by the similarity to ideal solution (TOPSIS) method. Our GPI approach and PCT screening are applied to three types of pollution sites: the refuse dump of a rare earth mine development project (a potential pollution source), a chromium slag dump, and a landfill (existing pollution sources). These three sites are identified as ordinary, prior, and ordinary sites, respectively. The anti-seepage materials at the refuse dump should perform as effectively as a 1.5-m-thick clay bed. The chromium slag dump should be preferentially treated by soil flushing and in situ chemical remediation. The landfill should be treated by natural attenuation technology. The proposed PCT screening approach was compared with conventional screening methods results at the three sites and proved feasible and effective. The proposed method can provide technical support for the monitoring and management of groundwater pollution in China. - Highlights: • An

  19. Method for screening prevention and control measures and technologies based on groundwater pollution intensity assessment

    International Nuclear Information System (INIS)

    Li, Juan; Yang, Yang; Huan, Huan; Li, Mingxiao; Xi, Beidou; Lv, Ningqing; Wu, Yi; Xie, Yiwen; Li, Xiang; Yang, Jinjin

    2016-01-01

    This paper presents a system for determining the evaluation and gradation indices of groundwater pollution intensity (GPI). Considering the characteristics of the vadose zone and pollution sources, the system decides which anti-seepage measures should be implemented at the contaminated site. The pollution sources hazards (PSH) and groundwater intrinsic vulnerability (GIV) are graded by the revised Nemerow Pollution Index and an improved DRTAS model, respectively. GPI is evaluated and graded by a double-sided multi-factor coupling model, which is constructed by the matrix method. The contaminated sites are categorized as prior, ordinary, or common sites. From the GPI results, we develop guiding principles for preventing and removing pollution sources, procedural interruption and remediation, and end treatment and monitoring. Thus, we can select appropriate prevention and control technologies (PCT). To screen the technological schemes and optimize the traditional analytical hierarchy process (AHP), we adopt the technique for order preference by the similarity to ideal solution (TOPSIS) method. Our GPI approach and PCT screening are applied to three types of pollution sites: the refuse dump of a rare earth mine development project (a potential pollution source), a chromium slag dump, and a landfill (existing pollution sources). These three sites are identified as ordinary, prior, and ordinary sites, respectively. The anti-seepage materials at the refuse dump should perform as effectively as a 1.5-m-thick clay bed. The chromium slag dump should be preferentially treated by soil flushing and in situ chemical remediation. The landfill should be treated by natural attenuation technology. The proposed PCT screening approach was compared with conventional screening methods results at the three sites and proved feasible and effective. The proposed method can provide technical support for the monitoring and management of groundwater pollution in China. - Highlights: • An

  20. Designing airport checked-baggage-screening strategies considering system capability and reliability

    International Nuclear Information System (INIS)

    Feng Qianmei; Sahin, Hande; Kapur, Kailash C.

    2009-01-01

    Emerging image-based technologies are critical components of airport security for screening checked baggage. Since these new technologies differ widely in cost and accuracy, a comprehensive mathematical framework should be developed for selecting technology or combination of technologies for efficient 100% baggage screening. This paper addresses the problem of setting threshold values of these screening technologies and determining the optimal combination of technologies in a two-level screening system by considering system capability and human reliability. Probability and optimization techniques are used to quantify and evaluate the cost- and risk-effectiveness of various deployment configurations, which is captured by using a system life-cycle cost model that incorporates the deployment cost, operating cost, and costs associated with system decisions. Two system decision rules are studied for a two-level screening system. For each decision rule, two different optimization approaches are formulated and investigated from practitioner's perspective. Numerical examples for different decision rules, optimization approaches and system arrangements are demonstrated

  1. Ring-Screening to Control Endemic Transmission of Taenia solium

    Science.gov (United States)

    O'Neal, Seth E.; Moyano, Luz M.; Ayvar, Viterbo; Rodriguez, Silvia; Gavidia, Cesar; Wilkins, Patricia P.; Gilman, Robert H.; Garcia, Hector H.; Gonzalez, Armando E.

    2014-01-01

    Background Taenia solium is a major cause of preventable epilepsy in developing nations. Screening and treatment of human intestinal stage infection (taeniasis) within high-risk foci may reduce transmission and prevent epilepsy by limiting human exposure to infective eggs. We piloted a ring-strategy that involves screening and treatment for taeniasis among households located nearby pigs heavily-infected with the larval stage (cysticercosis). These pigs mark areas of increased transmission and can be identified by tongue examination. Methodology We selected two villages in northern Peru for a controlled prospective interventional cohort pilot study. In the intervention village (1,058 residents) we examined the tongues of all pigs every 4 months for nodules characteristic of cysticercosis. We then screened all residents living within 100-meters of any tongue-positive pig using enzyme-linked immunosorbent assay to detect Taenia antigens in stool. Residents with taeniasis were treated with niclosamide. In both the intervention and control (753 residents) we measured incidence of exposure by sampling the pig population every 4 months for serum antibodies against cysticercosis using enzyme-linked immunoelectrotransfer blot. Principal Findings Baseline seroincidence among pigs born during the study was 22.6 cases per 100 pigs per-month (95% confidence interval [CI] 17.0–30.0) in the intervention and 18.1 (95% CI 12.7–25.9) in the control. After one year we observed a 41% reduction in seroincidence in the intervention village compared to baseline (incidence rate ratio 0.59, 95% CI 0.41–0.87) while the seroincidence in the control village remained unchanged. At study end, the prevalence of taeniasis was nearly 4 times lower in the intervention than in the control (prevalence ratio 0.28, 95% CI 0.08–0.91). Conclusions/Significance Ring-screening reduced transmission of T. solium in this pilot study and may provide an effective and practical approach for regions where

  2. Ring-screening to control endemic transmission of Taenia solium.

    Directory of Open Access Journals (Sweden)

    Seth E O'Neal

    2014-09-01

    Full Text Available Taenia solium is a major cause of preventable epilepsy in developing nations. Screening and treatment of human intestinal stage infection (taeniasis within high-risk foci may reduce transmission and prevent epilepsy by limiting human exposure to infective eggs. We piloted a ring-strategy that involves screening and treatment for taeniasis among households located nearby pigs heavily-infected with the larval stage (cysticercosis. These pigs mark areas of increased transmission and can be identified by tongue examination.We selected two villages in northern Peru for a controlled prospective interventional cohort pilot study. In the intervention village (1,058 residents we examined the tongues of all pigs every 4 months for nodules characteristic of cysticercosis. We then screened all residents living within 100-meters of any tongue-positive pig using enzyme-linked immunosorbent assay to detect Taenia antigens in stool. Residents with taeniasis were treated with niclosamide. In both the intervention and control (753 residents we measured incidence of exposure by sampling the pig population every 4 months for serum antibodies against cysticercosis using enzyme-linked immunoelectrotransfer blot.Baseline seroincidence among pigs born during the study was 22.6 cases per 100 pigs per-month (95% confidence interval [CI] 17.0-30.0 in the intervention and 18.1 (95% CI 12.7-25.9 in the control. After one year we observed a 41% reduction in seroincidence in the intervention village compared to baseline (incidence rate ratio 0.59, 95% CI 0.41-0.87 while the seroincidence in the control village remained unchanged. At study end, the prevalence of taeniasis was nearly 4 times lower in the intervention than in the control (prevalence ratio 0.28, 95% CI 0.08-0.91.Ring-screening reduced transmission of T. solium in this pilot study and may provide an effective and practical approach for regions where resources are limited. However, this strategy requires validation

  3. Air leakage control in chief tunnel of uranium mines using air screen

    International Nuclear Information System (INIS)

    Xiao Gengsheng

    1987-01-01

    In this paper the results of air leakage control are described using air screen in the chief tunnels of some uranium mines. The air leakage decreases by 79-91% after using air screen. On the basis of mathematical treatment, the formulas for calculating the air resistance efficiency of air screen are presented

  4. ScreenCube: A 3D Printed System for Rapid and Cost-Effective Chemical Screening in Adult Zebrafish.

    Science.gov (United States)

    Monstad-Rios, Adrian T; Watson, Claire J; Kwon, Ronald Y

    2018-02-01

    Phenotype-based small molecule screens in zebrafish embryos and larvae have been successful in accelerating pathway and therapeutic discovery for diverse biological processes. Yet, the application of chemical screens to adult physiologies has been relatively limited due to additional demands on cost, space, and labor associated with screens in adult animals. In this study, we present a 3D printed system and methods for intermittent drug dosing that enable rapid and cost-effective chemical administration in adult zebrafish. Using prefilled screening plates, the system enables dosing of 96 fish in ∼3 min, with a 10-fold reduction in drug quantity compared to that used in previous chemical screens in adult zebrafish. We characterize water quality kinetics during immersion in the system and use these kinetics to rationally design intermittent dosing regimens that result in 100% fish survival. As a demonstration of system fidelity, we show the potential to identify two known chemical inhibitors of adult tail fin regeneration, cyclopamine and dorsomorphin. By developing methods for rapid and cost-effective chemical administration in adult zebrafish, this study expands the potential for small molecule discovery in postembryonic models of development, disease, and regeneration.

  5. Healthcare costs in the Danish randomised controlled lung cancer CT-screening trial

    DEFF Research Database (Denmark)

    Rasmussen, J.F.; Siersma, V.; Pedersen, Jesper H.

    2014-01-01

    : This registry study was nested in a randomised controlled trial (DLCST). 4104 participants, current or former heavy smokers, aged 50-70 years were randomised to five annual low dose CT scans or usual care during 2004-2010. Total healthcare costs and healthcare utilisation data for both the primary...... and the secondary healthcare sector were retrieved from public registries from randomisation - September 2011 and compared between (1) the CT-screening group and the control group and, (2) the control group and each of the true-positive, false-positive and true-negative groups. RESULTS: The median annual costs per...... participant were significantly higher in the CT-screening group (Euros [EUR] 1342, interquartile range [IQR] 750-2980) compared with the control group (EUR 1190, IQR 590-2692) (pcost of the CT-screening programme was excluded, there was no longer a statistically significant difference...

  6. DEVELOPMENT AND INVESTIGATION OF LAYOUT OF ACTIVE SCREENING SYSTEM OF THE MAGNETIC FIELD GENERATED BY GROUP OF OVERHEAD TRANSMISSION LINES

    Directory of Open Access Journals (Sweden)

    B. I. Kuznetsov

    2018-04-01

    Full Text Available Purpose. Development and field experimental research of layout of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area is given. Methodology. Mathematical model of magnetic field, generated by group of high voltage transmission lines in residential area, based of the experimental values of magnetic field flux density in given points on the basis of optimization problem solving is improved. The objective of the synthesis of the single circuit active screening system is to determine their number, configuration, spatial arrangement, wiring diagrams and compensation cables currents, setting algorithm of the control systems as well as the resulting value of the magnetic flux density at the points of the protected space. Synthesis of the full-scale model of active screening system is reduced to the problem of multiobjective nonlinear programming with constraints in which calculation of the objective functions and constraints are carried out on the basis of the Maxwell equations solutions in the quasi-stationary approximation. The problem is solved by a stochastic multiswarm multi-agent particles optimization. Results. The single-circuit active screening system synthesis results for reduction of a magnetic field generated by group of high voltage transmission lines in residential area is given. Field experimental researches of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area with various control algorithms is given. Originality. For the first time out the development and field experimental studies of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area are carried out. Practical value. Practical recommendations on reasonable choice of the spatial arrangement of compensating cables of single

  7. A remote control system to offer information for nuclear power plant operation

    International Nuclear Information System (INIS)

    Ohga, Yukiharu; Yuchi, Hiroyuki; Arita, Setsuo

    1995-01-01

    A new man-machine system was proposed to simplify input operation so as to get needed plant information and to control information items and output devices for the operator crew, working in a control room. The system controls the shared information for the operator crew, on a large screen display, and private information for individual operators and maintenance personnel, on CRTs, based on the speech input and remote pointing input to the large screen display by a portable pointer, which emits laser beams. The system recognizes the indicating point of the pointer beam by processing the image on the large screen as obtained by an ITV camera. An infrared laser beam and a camera with a visible ray cut filter are used to remove distortion of the image caused by lens aberration, etc. and to provide rapid image processing. The operator performs the input operation while monitoring a cursor displayed by the system. The information items offered and their output devices are automatically determined according to the input operator. A prototype system was developed using three CRTs, one of which served as a substitute for the large screen display. Input to the system is performed using a speech input device and three kinds of pointers; each pointer is identified during image processing based on the number of laser beams emitted. The evaluation test confirmed that precise and smooth input by pointers as well as arbitrary combinations with speech input realized natural dialog without being aware of any waiting time. The appropriate information items were offered to output devices, CRTs and the speech output device, according to the pointers used, namely the input operators. The system can simplify input operation and effectively control the offered information items and output devices in a plant control room. (author)

  8. System of screen violence’s marking: problems and perspectives

    Directory of Open Access Journals (Sweden)

    E. V. Plyusnin

    2017-06-01

    Full Text Available Violence is so widespread on modern screens that it becomes to be especially important in the discourse of the humanitarian knowledge. Significantly actual is the problem of the impact of media content on the audience and ways of its effective regulation. In this connection, the need to create a system of control over the information space comes to the fore. In Ukraine there is no adequate model of the estimation of media content. As to our opinion, the existing rating system focuses the attention on age limitations and does not take into account the semantic characteristics that are used effectively in systems of Western countries. The problem of individuals’ protection from interaction with the content, which contains violence, can not be solved by the restriction of the access to information, but instead the situation of temptation to get what is tabooed is created. Despite the obvious usefulness of classification systems, the question of their modern low effectiveness arises, when it comes to the individuals’ protection from the undesirable audiovisual information. Attempts to revise the criteria for an objective analysis of media content were, in particular, the motivation for the creation of an alternative classification system, based on the principle of informing with the help of pictograms. A serious work on the study of various theoretical approaches to the research of the screen cruelty has been made by the author (the experiment by A. Bandura, the study by T. Payne’s fund of theoretical and experimental science on the impact of the violence on adolescent behavior, Gerbner’s cultivation theory, the hypothesis of catharsis by D. Zallman and R Gibson. It has been established that an individual who has not received the sufficient social experience and education level is at risk. There comes a threat of influence of factors capable, which can deform ideas about the world around us. Main definitions have been made in the article and

  9. Sequence Control System of 1-MW CW Klystron for the PEFP

    CERN Document Server

    Park, Byoung R; Chun Myung Hwan; Han Yeung Jin; Hyo Jeong Maeng; Kim Sung Chul; Yang Jae Seok; Yu In Ha

    2005-01-01

    Sequence control system of 1-MW CW klystron for the PEFP (Proton Engineering Frontier Project) has been developed in order to drive the 1-MW klystron amplifier. The system is able to control several power supplies and many environment conditions. The hardware of sequence control and the interlock system are based on the Allen-Bradley's SLC500 Program Logic Controller (PLC). Also the system can be controlled by a touch screen at local mode or Ethernet network with high level HMI at remote mode.

  10. Automated entry control system for nuclear facilities

    International Nuclear Information System (INIS)

    Ream, W.K.; Espinoza, J.

    1985-01-01

    An entry control system to automatically control access to nuclear facilities is described. The design uses a centrally located console, integrated into the regular security system, to monitor the computer-controlled passage into and out of sensitive areas. Four types of entry control points are used: an unmanned enclosed portal with metal and SNM detectors for contraband detection with positive personnel identification, a bypass portal for contraband search after a contraband alarm in a regular portal also with positive personnel identification, a single door entry point with positive personnel identification, and a single door entry point with only a magnetic card-type identification. Security force action is required only as a response to an alarm. The integration of the entry control function into the security system computer is also described. The interface between the entry control system and the monitoring security personnel utilizing a color graphics display with touch screen input is emphasized. 2 refs., 7 figs

  11. Development of an Excel-based laboratory information management system for improving workflow efficiencies in early ADME screening.

    Science.gov (United States)

    Lu, Xinyan

    2016-01-01

    There is a clear requirement for enhancing laboratory information management during early absorption, distribution, metabolism and excretion (ADME) screening. The application of a commercial laboratory information management system (LIMS) is limited by complexity, insufficient flexibility, high costs and extended timelines. An improved custom in-house LIMS for ADME screening was developed using Excel. All Excel templates were generated through macros and formulae, and information flow was streamlined as much as possible. This system has been successfully applied in task generation, process control and data management, with a reduction in both labor time and human error rates. An Excel-based LIMS can provide a simple, flexible and cost/time-saving solution for improving workflow efficiencies in early ADME screening.

  12. Non-visit-based cancer screening using a novel population management system.

    Science.gov (United States)

    Atlas, Steven J; Zai, Adrian H; Ashburner, Jeffrey M; Chang, Yuchiao; Percac-Lima, Sanja; Levy, Douglas E; Chueh, Henry C; Grant, Richard W

    2014-01-01

    Advances in information technology (IT) now permit population-based preventive screening, but the best methods remain uncertain. We evaluated whether involving primary care providers (PCPs) in a visit-independent population management IT application led to more effective cancer screening. We conducted a cluster-randomized trial involving 18 primary care practice sites and 169 PCPs from June 15, 2011, to June 14, 2012. Participants included adults eligible for breast, cervical, and/or colorectal cancer screening. In practices randomized to the intervention group, PCPs reviewed real-time rosters of their patients overdue for screening and provided individualized contact (via a letter, practice delegate, or patient navigator) or deferred screening (temporarily or permanently). In practices randomized to the comparison group, overdue patients were automatically sent reminder letters and transferred to practice delegate lists for follow-up. Intervention patients without PCP action within 8 weeks defaulted to the automated control version. The primary outcome was adjusted average cancer screening completion rates over 1-year follow-up, accounting for clustering by physician or practice. Baseline cancer screening rates (80.8% vs 80.3%) were similar among patients in the intervention (n = 51,071) and comparison group (n = 52,799). Most intervention providers used the IT application (88 of 101, 87%) and users reviewed 7984 patients overdue for at least 1 cancer screening (73% sent reminder letter, 6% referred directly to a practice delegate or patient navigator, and 21% deferred screening). In addition, 6128 letters were automatically sent to patients in the intervention group (total of 12,002 letters vs 16,378 letters in comparison practices; P management IT application resulted in similar cancer screening rates compared with an automated reminder system, but fewer patients were sent reminder letters. This suggests that PCPs were able to identify and exclude from contact

  13. [High-contrast resolution of film-screen systems in oral and maxillofacial radiology].

    Science.gov (United States)

    Kaeppler, G; Reinert, S

    2007-11-01

    The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same x-ray units as those used for patient radiographs. The MTF was determined using a lead grid and according to DIN 6867-2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). The relevance of this study is underlined by the diagnostic reference doses defined in the German X-ray Ordinance (RöV) which are also intended for dentistry. Film-screen systems (speed 250, speed class 200) previously used in dental panoramic and cephalometric radiography can be replaced by newly developed film-screen systems (speed class 400). In dental radiography dose reductions are possible with film-screen systems (speed class 400) without impairing diagnostic accuracy. The introduction of newly developed film-screen systems (speed class 400) requires lower milliampere-seconds and therefore an adjustment of the x-ray units to lower milliampere settings.

  14. A multifunction editor for programming control sequences for a robot based radiopharmaceutical synthesis system

    International Nuclear Information System (INIS)

    Appelquist, G.; Bohm, C.

    1990-01-01

    A Multifunction Editor is a development tool for building control sequences for a robotized production system for positron emitting radiopharmaceuticals. This system consists of SCARA robot and a PC-AT personal computer as a controller together with general and synthesis specific chemistry equipment. The general equipment, which is common for many synthesis, is fixed to the wall of the hotcell, while the specific equipment, dedicated to the given synthesis, is located on a removable tray. The program recognizes commands to move the robot, to control valves and to control the computer screen. From within the editor it is possible to run the control sequence forward or backward to test it and to use the single step feature to debug. The editor commands include insert, replace and delete of commands in the sequence. When programming or editing robot movements the robot may be controlled by the mouse, from the keyboard or from a remote control box. The robot control sequence consists of a succession of stored robot positions. The screen control is used to display dynamic flowchart diagrams. This is achieved by displaying a modified picture on the screen whenever the system state has been changed significantly

  15. Detection of pulmonary nodules. Improvement by new screen-film systems?

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Himmighoefer, U.

    1994-01-01

    In addition to digital radiography and AMBER, the development of asymmetric screen-film systems is another attempt to optimize chest radiography. Due to reduced contrast in the parenchyma, the former asymmetric screen-film systems did not show sufficient image quality. Three new asymmetric systems with completely different composition are available now. In-Sight VHC (Kodak), High Light GUV (3M) and Opthos D (Agfa) were compared to standard chest films using densitometric curves, a chest phantom for high and low contrast detectability, a nodule detection phantom and patient studies. The sensitivity of nodule detection in the mediastinum has been 41-48% for L-films and 58-65% for the asymmetric screen-film systems. No differences could be demonstrated for nodule detection in the lung field. Contrast in the parenchyma is equivalent to L-films. There is no loss of diagnostic information in the lung field. Differences between the asymmetric systems concern speed, dynamic range and granularity. If AMBER and digital radiography are not available, new asymmetric screen-film systems can improve nodule detection without further investment costs. (orig.) [de

  16. 75 FR 65151 - Marine Vapor Control Systems

    Science.gov (United States)

    2010-10-21

    ... Classification UFL Upper flammable limit USCG U.S. Coast Guard VCS Vapor control system VOC Volatile organic... transfer substance to new Subpart P, beginning with 33 CFR 154.2000, to facilitate the substantive changes... that guidance. Limit requirements for flame arresters or flame screens to the flammable, combustible...

  17. Pregnant Women's Perceptions of the Risks and Benefits of Disclosure During Web-Based Mental Health E-Screening Versus Paper-Based Screening: Randomized Controlled Trial.

    Science.gov (United States)

    Kingston, Dawn; Biringer, Anne; Veldhuyzen van Zanten, Sander; Giallo, Rebecca; McDonald, Sarah; MacQueen, Glenda; Vermeyden, Lydia; Austin, Marie-Paule

    2017-10-20

    Pregnant women's perceptions of the risks and benefits during mental health screening impact their willingness to disclose concerns. Early research in violence screening suggests that such perceptions may vary by mode of screening, whereby women view the anonymity of e-screening as less risky than other approaches. Understanding whether mode of screening influences perceptions of risk and benefit of disclosure is important in screening implementation. The objective of this randomized controlled trial was to compare the perceptions of pregnant women randomized to a Web-based screening intervention group and a paper-based screening control group on the level of risk and benefit they perceive in disclosing mental health concerns to their prenatal care provider. A secondary objective was to identify factors associated with women's perceptions of risk and benefit of disclosure. Pregnant women recruited from maternity clinics, hospitals, and prenatal classes were computer-randomized to a fully automated Web-based e-screening intervention group or a paper-based control. The intervention group completed the Antenatal Psychosocial Health Assessment and the Edinburgh Postnatal Depression Scale on a computer tablet, whereas the control group completed them on paper. The primary outcome was women's perceptions of the risk and benefits of mental health screening using the Disclosure Expectations Scale (DES). A completer analysis was conducted. Statistical significance was set at Pcontrol (n=331) groups. There were no significant baseline differences between groups. The mode of screening was not associated with either perceived risk or benefit of screening. There were no differences in groups in the mean scores of the risk and benefit of disclosure subscales. Over three-quarters of women in both intervention and control groups perceived that mental health screening was beneficial. However, 43.1% (272/631) of women in both groups reported feeling very, moderately, or somewhat

  18. A rule-based expert system for generating control displays at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Coulter, K.J.

    1993-01-01

    The integration of a rule-based expert system for generating screen displays for controlling and monitoring instrumentation under the Experimental Physics and Industrial Control System (EPICS) is presented. The expert system is implemented using CLIPS, an expert system shell from the Software Technology Branch at Lyndon B. Johnson Space Center. The user selects the hardware input and output to be displayed and the expert system constructs a graphical control screen appropriate for the data. Such a system provides a method for implementing a common look and feel for displays created by several different users and reduces the amount of time required to create displays for new hardware configurations. Users are able to modify the displays as needed using the EPICS display editor tool

  19. A rule-based expert system for generating control displays at the advanced photon source

    International Nuclear Information System (INIS)

    Coulter, K.J.

    1994-01-01

    The integration of a rule-based expert system for generating screen displays for controlling and monitoring instrumentation under the Experimental Physics and Industrial Control System (EPICS) is presented. The expert system is implemented using CLIPS, an expert system shell from the Software Technology Branch at Lyndon B. Johnson Space Center. The user selects the hardware input and output to be displayed and the expert system constructs a graphical control screen appropriate for the data. Such a system provides a method for implementing a common look and feel for displays created by several different users and reduces the amount of time required to create displays for new hardware configurations. Users are able to modify the displays as needed using the EPICS display editor tool. ((orig.))

  20. Eye Carduino: A Car Control System using Eye Movements

    Science.gov (United States)

    Kumar, Arjun; Nagaraj, Disha; Louzardo, Joel; Hegde, Rajeshwari

    2011-12-01

    Modern automotive systems are rapidly becoming highly of transportation, but can be a web integrated media centre. This paper explains the implementation of a vehicle control defined and characterized by embedded electronics and software. With new technologies, the vehicle industry is facing new opportunities and also new challenges. Electronics have improved the performance of vehicles and at the same time, new more complex applications are introduced. Examples of high level applications include adaptive cruise control and electronic stability programs (ESP). Further, a modern vehicle does not have to be merely a means using only eye movements. The EyeWriter's native hardware and software work to return the co-ordinates of where the user is looking. These co-ordinates are then used to control the car. A centre-point is defined on the screen. The higher on the screen the user's gaze is, the faster the car will accelerate. Braking is done by looking below centre. Steering is done by looking left and right on the screen.

  1. Operational experience with the CEBAF control system

    International Nuclear Information System (INIS)

    Hovater, C.; Chowdhary, M.; Karn, J.; Tiefenback, M.; Zeijts, J. van; Watson, W.

    1996-01-01

    The CEBAF accelerator at Thomas Jefferson National Accelerator Facility (Jefferson Lab) successfully began its experimental nuclear physics program in November of 1995 and has since surpassed predicted machine availability. Part of this success can be attributed to using the EPICS (Experimental Physics and Industrial Control System) control system toolkit. The CEBAF control system is one of the largest accelerator control system now operating. It controls approximately 338 SRF cavities, 2,300 magnets, 500 beam position monitors and other accelerator devices, such as gun hardware and other beam monitoring devices. All told, the system must be able to access over 125,000 database records. The system has been well received by both operators and the hardware designers. The EPICS utilities have made the task of troubleshooting systems easier. The graphical and test-based creation tools have allowed operators to custom build control screens. In addition, the ability to integrate EPICS with other software packages, such as Tcl/Tk, has allowed physicists to quickly prototype high-level application programs, and to provide GUI front ends for command line driven tools. Specific examples of the control system applications are presented in the areas of energy and orbit control, cavity tuning and accelerator tune up diagnostics

  2. A history of breast cancer screening and future problems in Japan

    International Nuclear Information System (INIS)

    Morimoto, Tadaoki

    2009-01-01

    In Europe and the United States, mortality due to breast cancer is decreasing. There are various reasons for this trend, including an increase in the detection of early-stage breast cancers due to the increased use of mammographic screening, and the establishment of standardized systemic treatments derived from evidence-based medicine (EBM). On the other hand, in Japanese women, both morbidity and mortality due to breast cancer are increasing. This paper describes the process of breast cancer screening in the past, its current status, and the quality control system for mammographic screening in Japan, as well as the status of breast cancer screening in Europe and the United States. Furthermore, problems of breast cancer screening in Japan discussed, together with the need for practical measures such as implementation of quality control systems aimed at improving the cancer screening rate (with a target of 50%), financial support, and population-based screening (organized screening), based on the Cancer Control Act. Current measures for screening of dense breast tissue in women in their 40s in Japan are also described. (author)

  3. Breast cancer screening effect across breast density strata: A case-control study.

    Science.gov (United States)

    van der Waal, Daniëlle; Ripping, Theodora M; Verbeek, André L M; Broeders, Mireille J M

    2017-01-01

    Breast cancer screening is known to reduce breast cancer mortality. A high breast density may affect this reduction. We assessed the effect of screening on breast cancer mortality in women with dense and fatty breasts separately. Analyses were performed within the Nijmegen (Dutch) screening programme (1975-2008), which invites women (aged 50-74 years) biennially. Performance measures were determined. Furthermore, a case-control study was performed for women having dense and women having fatty breasts. Breast density was assessed visually with a dichotomized Wolfe scale. Breast density data were available for cases. The prevalence of dense breasts among controls was estimated with age-specific rates from the general population. Sensitivity analyses were performed on these estimates. Screening performance was better in the fatty than in the dense group (sensitivity 75.7% vs 57.8%). The mortality reduction appeared to be smaller for women with dense breasts, with an odds ratio (OR) of 0.87 (95% CI 0.52-1.45) in the dense and 0.59 (95% CI 0.44-0.79) in the fatty group. We can conclude that high density results in lower screening performance and appears to be associated with a smaller mortality reduction. Breast density is thus a likely candidate for risk-stratified screening. More research is needed on the association between density and screening harms. © 2016 UICC.

  4. The research on noise equivalent quanta and detective quantum efficiency of screen-film system

    International Nuclear Information System (INIS)

    Xie Jingdong; Wang Changyuan; Yuan Yude; Zhang Menglong; Wang Jian; Zheng Hao; Sun Yong

    2002-01-01

    Objective: To examine the noise equivalent quanta (NEQ) and detective quantum efficiency (DQE) of screen-film system. Methods: Green 400 screen-Kodak film and CaWO 4 screen-Fuji film were used in the study. The characteristic curves were obtained by distance method. The square wave technique was employed to determine the modulation transfer function (MTF). The Wiener spectrum (WS) was determined by Fourier analysis on uniformly exposed films. The NEQ and DQE were calculated from the characteristic curve slope, MTF, and WS measurements. Results: (1) The NEQ value of Green 400 screen-Kodak film system was 1.48 x 10 6 mm -2 when the spatial frequency was 0.6 cycles/mm, and it was 0.65 times larger than that of CaWO 4 screen-Fuji film system; The NEQ value of Green 400 screen-Kodak film system was 0.329 x 10 4 mm -2 when the spatial frequency was 4.0 cycles/mm, and it was 1.55 times larger than that of CaWO 4 screen-Fuji film system. (2) The DQE value of Green 400 screen-Kodak film system was 0.224 when the spatial frequency was 0.6 cycles/mm, and it was 1.6 times larger than that of CaWO 4 screen-Fuji film system; The DQE value of Green 400 screen-Kodak film system was 0.052 when the spatial frequency was 4.0 cycles/mm, and it was 3.7 times larger than that of CaWO 4 screen-Fuji film system. Conclusion: The Green 400 Screen-Kodak film system has superior NEQ when the spatial frequency was more than 3.0 cycles/mm and has superior DQE among the total spatial frequency in comparison with CaWO 4 screen-Fuji film system

  5. Functional Movement Screen (FMS - kompleksowy system oceny funkcjonalnej pacjenta = Functional Movement Screen (FMS - a comprehensive system for the functional evaluation of the patient

    Directory of Open Access Journals (Sweden)

    Bartosz Kochański

    2015-04-01

    4 Wydział Kultury Fizycznej, Zdrowia i Turystyki, Uniwersytet Kazimierza Wielkiego w Bydgoszczy, Polska   Streszczenie   System oceny funkcjonalnej - Functional Movement Screen (FMS został stworzony przez Graya Cooka oraz Lee Burtona w 1995 roku. FMS jest koncepcją, która umożliwia kompleksową analizę jakości podstawowych wzorców ruchowych, ocenę ryzyka kontuzji oraz stwierdzenie istnienia ograniczeń i asymetrii. Test FMS złożony jest z 7 prób (głęboki przysiad, przeniesienie kończyny dolnej nad płotkiem, przysiad w wykroku, ruchomość obręczy barkowej, aktywne uniesienie wyprostowanej kończyny dolnej, ugięcie ramion w podporze, stabilność rotacyjna tułowia. W pracy zaprezentowano test Functional Movement Screen, jako kompleksowy system oceny funkcjonalnej pacjenta.   Słowa kluczowe: Functional Movement Screen, FMS, ocena funkcjonalna, rehabilitacja.   Abstract   Functional Movement Screen (FMS was created by Gray Cook and Lee Burton in 1995. FMS is a concept that allows comprehensive analysis of the quality of basic movement patterns, risk assessment and finding of injury to the limitations and asymmetries. FMS test consists of 7 samples (deep squat, hurdle step, in-line lunge, shoulder mobility, active straight leg raise, trunk stability push up, rotational stability. The paper presents the Functional Movement Screen test, as a comprehensive system of functional assessment of the patient.   Key words: Functional Movement Screen, FMS, functional assessment, rehabilitation.

  6. Automated refueling inventory control system at FFTF

    International Nuclear Information System (INIS)

    Ordonez, C.R.

    1983-10-01

    The Refueling Inventory Control System (RICS) at the Fast Flux Test Facility (FFTF) keeps track of all assemblies that reside in the various refueling facilities. The automated RICS allows the user to obtain information regarding any assembly under its control by displaying the data on a screen. It also provides a simulation mode which allows assembly moves on a duplicated data base. This simulation is used to verify the refueling documentation before it is issued

  7. The TRISTAN control system

    International Nuclear Information System (INIS)

    Kurokawa, Shinichi; Akiyama, Atsuyoshi; Ishii, Kazuhiro; Kadokura, Eiichi; Katoh, Tadahiko; Kawamoto, Takashi; Kikutani, Eiji; Kimura, Yoshitaka; Koiso, Haruyo; Komada, Ichitaka; Kudo, Kikuo; Naito, Takashi; Oide, Katsunobu; Takeda, Shigeru; Uchino, Kenji; Urakawa, Junji; Shinomoto, Manabu; Kurihara, Michio; Abe, Kenichi

    1986-01-01

    The 8 GeV accumulation ring and the 30 GeV main ring of TRISTAN, an accelerator-storage ring complex at KEK, are controlled by a highly computerized control system. Twenty-four minicomputers are linked by optical fiber cables to form an N-to-N token ring network. The transmission speed on the cables is 10 Mbps. From each minicomputer, a CAMAC serial highway extends to the controlled equipment. At present, twenty minicomputers are connected to the network and are used to control the accumulation ring. The software system is based on the NODAL language devised at the CERN SPS. The KEK NODAL system retains main features of the original NODAL: the interpretive scheme, the multi-computer programming facility, and the data-module concept. In addition, it has the following features: (1) fast execution due to the compiler-interpreter method, (2) a multi-computer file system (3), a full-screen editing facility, and (4) a dynamic linkage scheme for data modules and NODAL functions. The accelerators are operated through five operator consoles, each of which is mangaged by one minicomputer in the network. An operator console contains two 20-inch high-resolution color graphic displays, a pair of touch-panels, and ten small TV monitors. One touch-panel is used to select a program and a piece of equipment to be controlled; the other is used mainly to perform the console actions. (orig.)

  8. Effect of intensifying screens to subject contrast

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon; Kang, Hong Seok; Yoon, Chul Ho

    1990-01-01

    It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows ; 1. In the same object radiography, use acquired the difference of the object contrast between LT-II(CaWO 4 system) and G4(Gd system) screens. 2. object contrast more decreased in Gd system screen than CaWO 4 and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp

  9. LIRA - License Renewal Assistant an expert system advisor for system and component screening

    International Nuclear Information System (INIS)

    Wood, R.M.; DeLuke, R.J.; Lu, Yi; Catron, S.R.

    1992-01-01

    In developing a license renewal application for a nuclear power plant, it is necessary to identify those systems and components for which age-related degradation must be evaluated and addressed in detail. One approach, used in the Monticello Lead Plant project, is to screen all plant systems and components, based on criteria developed by the Nuclear Utility Management and Resources Council (NUMARC). This paper describes an expert system developed as an assistant in the application of the screening methodology. 4 refs., 5 figs., 1 tab

  10. Control of pore size in epoxy systems.

    Energy Technology Data Exchange (ETDEWEB)

    Sawyer, Patricia Sue; Lenhart, Joseph Ludlow (North Dakota State University, Fargo, ND); Lee, Elizabeth (North Dakota State University, Fargo, ND); Kallam, Alekhya (North Dakota State University, Fargo, ND); Majumdar, Partha (North Dakota State University, Fargo, ND); Dirk, Shawn M.; Gubbins, Nathan; Chisholm, Bret J. (North Dakota State University, Fargo, ND); Celina, Mathias C.; Bahr, James (North Dakota State University, Fargo, ND); Klein, Robert J.

    2009-01-01

    Both conventional and combinatorial approaches were used to study the pore formation process in epoxy based polymer systems. Sandia National Laboratories conducted the initial work and collaborated with North Dakota State University (NDSU) using a combinatorial research approach to produce a library of novel monomers and crosslinkers capable of forming porous polymers. The library was screened to determine the physical factors that control porosity, such as porogen loading, polymer-porogen interactions, and polymer crosslink density. We have identified the physical and chemical factors that control the average porosity, pore size, and pore size distribution within epoxy based systems.

  11. Network performance for graphical control systems

    International Nuclear Information System (INIS)

    Clout, P.; Geib, M.; Westervelt, R.

    1992-01-01

    Vsystem is a toolbox for building graphically-based control systems. The real-tiem database component, Vaccess, includes all the networking support necessary to build multi-computer control systems. Vaccess has two modes of database access, synchronous and asynchronous. Vdraw is another component of Vsystem that allows developers and users to develop control screens and windows by drawing rather than programming. Based on X-windows, Vsystem provides the possibility of running Vdraw either on the workstation with the graphics or on the computer with the database. We have made some measurements on the cpu loading, elapsed time and the network loading to give some guidance in system configuration performance. It will be seen that asynchronous network access gives large performance increases and that the network database change notification protocol can be either more or less efficient than the X-window network protocol, depending on the graphical representation of the data. (author)

  12. Quality Control in Screening for Infectious Diseases at Blood Banks. Rationale and Methodology.

    Science.gov (United States)

    Sáez-Alquezar, Amadeo; Albajar-Viñas, Pedro; Guimarães, André Valpassos; Corrêa, José Abol

    2015-11-01

    Quality control procedures are indispensable to ensure the reliability of the results provided by laboratories responsible for serological screening in blood banks. International recommendations on systems of quality management classify as a top component the inclusion of two types of control: (a) internal quality control (IQC) and (b) external quality control (EQC). In EQC it is essential to have, at least, a monthly frequency of laboratory assessment. On the other hand, IQC involves the daily use of low-reactivity control sera, which should be systematically added in all run, carried out in the laboratory for each parameter. Through the IQC analysis some variations in the criteria of run acceptance and rejection may be revealed, but it is of paramount importance to ensure the previous definition of these criteria and even more importantly, the adherence to them; and that corresponds to the validation of analytical runs of each test. Since 2010 this has been, for instance, the experience of the PNCQ*, developing external quality control programmes on serology for blood banks. These programmes use samples of lyophilized sera well-characterized for the reactivity related to the parameters used for the serological screening of blood donors. The programmes have used blind panels of six samples for monthly assessments. In the last 50 assessments, which involved 68 blood banks in Brazil, a significant number of instances of non-compliance were observed in all monthly assessments. These results provide strong support to the recommendation of systematic monthly assessments. (*) National Quality Control Programme (PNCQ).

  13. Treatment verification system in radiotherapy using a digital portal imaging device. Comparison with screen/film systems

    International Nuclear Information System (INIS)

    Nakata, Manabu; Komai, Yoshinori; Okada, Takashi; Fukumoto, Satoshi; Chadani, Kazuma; Nohara, Hiroki; Kazusa, Chudou.

    1994-01-01

    A digital portal imaging (DPI) system for megavoltage photon beams was installed recently in our department. The purpose of this study is to evaluate the image quality of this system. We have analyzed the following properties of the system; relationship between measured dose-rate and pixel values of the DPI, spatial resolution, detectability of low-contrast objects and setup errors. The results were compared with those of conventional screen-film systems. As a result, the relationship between the measured dose-rate and the pixel value of the DPI was found to be linear in the dose-rate range between 100 and 400 cGy/min. Spatial resolution was 1.25 and 0.5 mm for the DPI and the screen-film systems, respectively. The slope of the contrast-detail curves differed between the DPI and the screen-film systems, the contrast thresholds were 0.6 and 0.3% for the DPI and the screen-film systems, respectively. The detectability of a setup error of 1 mm and 2 mm for the DPI was lower than that by the screen-film systems, although the difference was not very significant. In conclusion, the image quality of the DPI at present time is slightly inferior to the conventional screen-film systems. However, notable advantages of the DPI system are that any positional changes in patients during irradiation can be detected very quickly, and that quantitative analysis of the setup variation can be obtained. The image quality of the DPI will be improved as the technology regarding advances. Therefore, this verification system using the DPI device, is expected to be used for clinical radiation therapy in the future. (author)

  14. Fuel cycle facility control system for the Integral Fast Reactor Program

    International Nuclear Information System (INIS)

    Benedict, R.W.; Tate, D.A.

    1993-01-01

    As part of the Integral Fast Reactor (IFR) Fuel Demonstration, a new distributed control system designed, implemented and installed. The Fuel processes are a combination of chemical and machining processes operated remotely. To meet this special requirement, the new control system provides complete sequential logic control motion and positioning control and continuous PID loop control. Also, a centralized computer system provides near-real time nuclear material tracking, product quality control data archiving and a centralized reporting function. The control system was configured to use programmable logic controllers, small logic controllers, personal computers with touch screens, engineering work stations and interconnecting networks. By following a structured software development method the operator interface was standardized. The system has been installed and is presently being tested for operations

  15. Effect of transient liquid flow on retention characteristics of screen acquisition systems. [design of Space Shuttle feed system

    Science.gov (United States)

    Cady, E. C.

    1977-01-01

    A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

  16. An automated entry control system for nuclear facilities

    International Nuclear Information System (INIS)

    Ream, W.K.; Espinoza, J.

    1985-01-01

    An entry control system to automatically control access to nuclear facilities is described. The design uses a centrally located console, integrated into the regular security system, to monitor the computer-controlled passage into and out of sensitive areas. Four types of entry control points are used: an unmanned enclosed portal with metal and SNM detectors for contraband detection with positive personnel identification, a bypass portal for contraband search after a contraband alarm in a regular portal also with positive personnel identification, a single door entry point with positive personnel identification, and a single door entry point with only a magnetic card-type identification. Security force action is required only as a response to an alarm. The integration of the entry control function into the security system computer is also described. The interface between the entry control system and the monitoring security personnel utilizing a color graphics display with touch screen input is emphasized

  17. A novel hanging spherical drop system for the generation of cellular spheroids and high throughput combinatorial drug screening.

    Science.gov (United States)

    Neto, A I; Correia, C R; Oliveira, M B; Rial-Hermida, M I; Alvarez-Lorenzo, C; Reis, R L; Mano, J F

    2015-04-01

    We propose a novel hanging spherical drop system for anchoring arrays of droplets of cell suspension based on the use of biomimetic superhydrophobic flat substrates, with controlled positional adhesion and minimum contact with a solid substrate. By facing down the platform, it was possible to generate independent spheroid bodies in a high throughput manner, in order to mimic in vivo tumour models on the lab-on-chip scale. To validate this system for drug screening purposes, the toxicity of the anti-cancer drug doxorubicin in cell spheroids was tested and compared to cells in 2D culture. The advantages presented by this platform, such as feasibility of the system and the ability to control the size uniformity of the spheroid, emphasize its potential to be used as a new low cost toolbox for high-throughput drug screening and in cell or tissue engineering.

  18. The Design and Development of the Precision Planter Sowing Depth Control System

    Directory of Open Access Journals (Sweden)

    Liping WEN

    2014-01-01

    Full Text Available In view the accuracy requirements of sowing depth control for precision planter, we carried out the design and development of control system. This paper main includes the working principle of the control system, the hardware and software design of electro-hydraulic proportional control system. It also respectively explains the software programming of PLC, the software programming of touch screen. Practical application shows that this system has advantages of stable operation, high reliability, convenient operation and maintenance, with high promotion and use value.

  19. Efficacy of screening immune system function in at-risk newborns

    OpenAIRE

    Pavlovski, Christopher J

    2014-01-01

    This paper explores the introduction of a screening test to highlight impaired immune system status for newborn infants and its efficacy as a preventative clinical measure. Moreover, it is suggested that screening of the infantile immune system has the potential to highlight susceptibility to a range of infant and childhood diseases, bestowing an opportunity to introduce early intervention to reduce the incidence of these diseases. Development of the neonatal immune system is an important hea...

  20. Emulating a robotic manipulator arm with an hybrid motion-control system

    International Nuclear Information System (INIS)

    Aragón-González, G; León-Galicia, A; Noriega-Hernández, M; Salazar-Hueta, A

    2015-01-01

    A motion control system with four and 1/2 degrees of freedom, designed to move small objects within a 0.25 m3 space, parallel to a horizontal table, with high speed and performance similar to a robotic manipulator arm was built. The machine employs several actuators and control devices. Its main characteristic is to incorporate a servomotor, steeper motors, electromechanical and fluid power actuators and diverse control resources. A group of actuators arranged on a spherical coordinates system is attached to the servomotor platform. A linear pneumatic actuator with an angular grip provides the radial extension and load clamping capacity. Seven inductive proximity sensors and one encoder provide feedback, for operating the actuators under closed loop conditions. Communication between the sensors and control devices is organized by a PLC. A touch screen allows governing the system remotely, easily and interactively, without knowing the specific programming language of each control component. The graphic environment on the touch screen guides the user to design and store control programs, establishing coordinated automatic routines for moving objects in space, simulation and implementation of industrial positioning or machining processes

  1. Seismic evaluation of piping systems using screening criteria

    International Nuclear Information System (INIS)

    Campbell, R.D.; Landers, D.F.; Minichiello, J.C.; Slagis, G.C.; Antaki, G.A.

    1994-01-01

    This document may be used by a qualified review team to identify potential sources of seismically induced failure in a piping system. Failure refers to the inability of a piping system to perform its expected function following an earthquake, as defined in Table 1. The screens may be used alone or with the Seismic Qualification Utility Group -- Generic Implementation Procedure (SQUG-GIP), depending on the piping system's required function, listed in Table 1. Features of a piping system which do not the screening criteria are called outliers. Outliers must either be resolved through further evaluations, or be considered a potential source of seismically induced failure. Outlier evaluations, which do not necessarily require the qualification of a complete piping system by stress analysis, may be based on one or more of the following: simple calculations of pipe spans, search of the test or experience data, vendor data, industry practice, etc

  2. The screening effects of the screened exchange hybrid functional in surface systems: A case study on the CO/Pt(111) problem

    Energy Technology Data Exchange (ETDEWEB)

    Li, H., E-mail: li-huanglong@mail.tsinghua.edu.cn [Department of Precision Instrument, Tsinghua University, Beijing, 100084 (China); Gillen, R. [Institut für Festkörperphysik. Technische Universität Berlin. Hardenbergstr. 36, 10623 Berlin (Germany); Robertson, J., E-mail: jr214@cam.ac.uk [Engineering Department, University of Cambridge, Cambridge CB2 1PZ (United Kingdom)

    2016-06-15

    The screened exchange (sX) hybrid functional has been widely used in computational material science. Although it has widely been studied in bulk systems, less is known about its functional behavior in surface systems which are crucial to many technologies such as materials synthesis and nano-electronic devices. Assessing the screening dependent functional behaviors in the surface systems is therefore important for its application in such systems. In this work, we investigate the screening effects of the sX in CO adsorption on Pt(111) surface. The differences between the sX and Heyd-Scuseria-Ernzerhof (HSE06) hybrid functionals, and the effects of screening parameters are studied. The screening has two effects: first, the HOMO-LUMO gap is screening dependent. This affects the site preference most significantly. In this work, atop adsorption of CO/Pt(111) is predicted by the hybrid functionals with screened exchange potential. The sX(1.44) gives the largest HOMO-LUMO gap for the isolated CO molecule. The adsorption energy difference between the atop and fcc site is also the largest by the sX(1.44) which is explained by the reduced metal d states to the CO 2π* state back-donation, with stronger effect for the fcc adsorption than for the atop adsorption; second, the adsorption energy is screening dependent. This can be seen by comparing the sX(2.38) and HSE06 which have different screening strengths. They show similar surface band structures for the CO adsorption but different adsorption energies, which is explained by the stronger CO 5σ state to the metal d states donation or the effectively screened Pauli repulsion. This work underlines the screening strength as a main difference between sX and HSE06, as well as an important hybrid functional parameter for surface calculation.

  3. [Colonoscopy quality control as a requirement of colorectal cancer screening].

    Science.gov (United States)

    Quintero, Enrique; Alarcón-Fernández, Onofre; Jover, Rodrigo

    2013-11-01

    The strategies used in population-based colorectal screening strategies culminate in colonoscopy and consequently the success of these programs largely depends on the quality of this diagnostic test. The main factors to consider when evaluating quality are scientific-technical quality, safety, patient satisfaction, and accessibility. Quality indicators allow variability among hospitals, endoscopy units and endoscopists to be determined and can identify those not achieving recommended standards. In Spain, the working group for colonoscopy quality of the Spanish Society of Gastroenterology and the Spanish Society of Gastrointestinal Endoscopy have recently drawn up a Clinical Practice Guideline that contains the available evidence on the quality of screening colonoscopy, as well as the basic requirements that must be met by endoscopy units and endoscopists carrying out this procedure. The implementation of training programs and screening colonoscopy quality controls are strongly recommended to guarantee the success of population-based colorectal cancer screening. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  4. Effect of providing risk information on undergoing cervical cancer screening: a randomized controlled trial.

    Science.gov (United States)

    Fujiwara, Hiroyuki; Shimoda, Akihiro; Ishikawa, Yoshiki; Taneichi, Akiyo; Ohashi, Mai; Takahashi, Yoshifumi; Koyanagi, Takahiro; Morisawa, Hiroyuki; Takahashi, Suzuyo; Sato, Naoto; Machida, Shizuo; Takei, Yuji; Saga, Yasushi; Suzuki, Mitsuaki

    2015-01-01

    In Japan, the cervical cancer screening rate is extremely low. Towards improving the cervical cancer screening rate, encouraging eligible people to make an informed choice, which is a decision-making process that relies on beliefs informed by adequate information about the possible benefits and risks of screening, has attracted increased attention in the public health domain. However, there is concern that providing information on possible risks of screening might prevent deter from participating. In total, 1,912 women aged 20-39 years who had not participated in screening in the fiscal year were selected from a Japanese urban community setting. Participants were randomly divided into 3 groups. Group A received a printed reminder with information about the possible benefits of screening, group B received a printed reminder with information about possible benefits and risks, and group C received a printed reminder with simple information only (control group). Out of 1,912 participants, 169 (8.8%) participated in cervical cancer screening. In the intervention groups, 137 (10.9%) participated in cervical cancer screening, compared to only 32 (4.9%) of the control group (p < 0.001). In addition, logistic regression analysis revealed that there was no significant difference in screening rate between group A and group B (p = 0.372). Providing information on the possible risks of screening may not prevent people from taking part in cervical cancer screening among a Japanese non-adherent population.

  5. Screening for heart transplantation and left ventricular assist system

    DEFF Research Database (Denmark)

    Lund, Lars H; Trochu, Jean-Noel; Meyns, Bart

    2018-01-01

    BACKGROUND: Heart transplantation (HTx) and implantable left ventricular assist systems (LVAS) improve outcomes in advanced heart failure but may be underutilized. We hypothesized that screening can identify appropriate candidates. METHODS AND RESULTS: The ScrEEning for advanced Heart Failure...... treatment (SEE-HF) study was a multicentre prospective study screening patients with existing cardiac resynchronization therapy (CRT) and/or implantable cardioverter-defibrillator (ICD) for ejection fraction ≤40% and New York Heart Association (NYHA) class III-IV, and subsequently for guideline-based HTx...

  6. Simulator comparison of thumball, thumb switch, and touch screen input concepts for interaction with a large screen cockpit display format

    Science.gov (United States)

    Jones, Denise R.; Parrish, Russell V.

    1990-01-01

    A piloted simulation study was conducted comparing three different input methods for interfacing to a large screen, multiwindow, whole flight deck display for management of transport aircraft systems. The thumball concept utilized a miniature trackball embedded in a conventional side arm controller. The multifunction control throttle and stick (MCTAS) concept employed a thumb switch located in the throttle handle. The touch screen concept provided data entry through a capacitive touch screen installed on the display surface. The objective and subjective results obtained indicate that, with present implementations, the thumball concept was the most appropriate for interfacing with aircraft systems/subsystems presented on a large screen display. Not unexpectedly, the completion time differences between the three concepts varied with the task being performed, although the thumball implementation consistently outperformed the other two concepts. However, pilot suggestions for improved implementations of the MCTAS and touch screen concepts could reduce some of these differences.

  7. High-contrast resolution of film-screen systems in oral and maxillofacial radiology

    International Nuclear Information System (INIS)

    Kaeppler, G.; Reinert, S.

    2007-01-01

    Purpose: The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same X-ray units as those used for patient radiographs. Materials and methods: The MTF was determined using a lead grid and according to DIN 6867 - 2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. Results: With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). (orig.)

  8. Applying operations research to optimize a novel population management system for cancer screening.

    Science.gov (United States)

    Zai, Adrian H; Kim, Seokjin; Kamis, Arnold; Hung, Ken; Ronquillo, Jeremiah G; Chueh, Henry C; Atlas, Steven J

    2014-02-01

    To optimize a new visit-independent, population-based cancer screening system (TopCare) by using operations research techniques to simulate changes in patient outreach staffing levels (delegates, navigators), modifications to user workflow within the information technology (IT) system, and changes in cancer screening recommendations. TopCare was modeled as a multiserver, multiphase queueing system. Simulation experiments implemented the queueing network model following a next-event time-advance mechanism, in which systematic adjustments were made to staffing levels, IT workflow settings, and cancer screening frequency in order to assess their impact on overdue screenings per patient. TopCare reduced the average number of overdue screenings per patient from 1.17 at inception to 0.86 during simulation to 0.23 at steady state. Increases in the workforce improved the effectiveness of TopCare. In particular, increasing the delegate or navigator staff level by one person improved screening completion rates by 1.3% or 12.2%, respectively. In contrast, changes in the amount of time a patient entry stays on delegate and navigator lists had little impact on overdue screenings. Finally, lengthening the screening interval increased efficiency within TopCare by decreasing overdue screenings at the patient level, resulting in a smaller number of overdue patients needing delegates for screening and a higher fraction of screenings completed by delegates. Simulating the impact of changes in staffing, system parameters, and clinical inputs on the effectiveness and efficiency of care can inform the allocation of limited resources in population management.

  9. Control system user interface for accelerator commissioning and operation

    International Nuclear Information System (INIS)

    Dobrott, D.; Keeley, D.; Kolte, G.; Mikic, Z.; Lee, M.; Corbett, J.; Howry, S.; King, A.

    1991-01-01

    An Interactive Accelerator Interface Module (AIM) has been developed in a workstation environment for the purposes of assisting in the commissioning and operation of any storage ring/collider system. The function of AIM is to integrate modeling and simulation codes into accelerator and beamline control systems for the purpose of rapid on-line data analysis and error-correction, resulting in significant time-saving. A system dependent module provides for the translation of specific control system data files to appropriate input format for application programs within AIM. Interactive screen graphics, including system function diagrams, menus, beamline element status and update information are standard in AIM. AIM is currently connected to the Stanford Linear Collider (SLC) control system, but is easily transportable to other facilities. This paper describes the development of AIM and its applications on SLC

  10. TeraSCREEN: multi-frequency multi-mode Terahertz screening for border checks

    Science.gov (United States)

    Alexander, Naomi E.; Alderman, Byron; Allona, Fernando; Frijlink, Peter; Gonzalo, Ramón; Hägelen, Manfred; Ibáñez, Asier; Krozer, Viktor; Langford, Marian L.; Limiti, Ernesto; Platt, Duncan; Schikora, Marek; Wang, Hui; Weber, Marc Andree

    2014-06-01

    The challenge for any security screening system is to identify potentially harmful objects such as weapons and explosives concealed under clothing. Classical border and security checkpoints are no longer capable of fulfilling the demands of today's ever growing security requirements, especially with respect to the high throughput generally required which entails a high detection rate of threat material and a low false alarm rate. TeraSCREEN proposes to develop an innovative concept of multi-frequency multi-mode Terahertz and millimeter-wave detection with new automatic detection and classification functionalities. The system developed will demonstrate, at a live control point, the safe automatic detection and classification of objects concealed under clothing, whilst respecting privacy and increasing current throughput rates. This innovative screening system will combine multi-frequency, multi-mode images taken by passive and active subsystems which will scan the subjects and obtain complementary spatial and spectral information, thus allowing for automatic threat recognition. The TeraSCREEN project, which will run from 2013 to 2016, has received funding from the European Union's Seventh Framework Programme under the Security Call. This paper will describe the project objectives and approach.

  11. Distributed computer control system for reactor optimization

    International Nuclear Information System (INIS)

    Williams, A.H.

    1983-01-01

    At the Oldbury power station a prototype distributed computer control system has been installed. This system is designed to support research and development into improved reactor temperature control methods. This work will lead to the development and demonstration of new optimal control systems for improvement of plant efficiency and increase of generated output. The system can collect plant data from special test instrumentation connected to dedicated scanners and from the station's existing data processing system. The system can also, via distributed microprocessor-based interface units, make adjustments to the desired reactor channel gas exit temperatures. The existing control equipment will then adjust the height of control rods to maintain operation at these temperatures. The design of the distributed system is based on extensive experience with distributed systems for direct digital control, operator display and plant monitoring. The paper describes various aspects of this system, with particular emphasis on: (1) the hierarchal system structure; (2) the modular construction of the system to facilitate installation, commissioning and testing, and to reduce maintenance to module replacement; (3) the integration of the system into the station's existing data processing system; (4) distributed microprocessor-based interfaces to the reactor controls, with extensive security facilities implemented by hardware and software; (5) data transfer using point-to-point and bussed data links; (6) man-machine communication based on VDUs with computer input push-buttons and touch-sensitive screens; and (7) the use of a software system supporting a high-level engineer-orientated programming language, at all levels in the system, together with comprehensive data link management

  12. Applying operations research to optimize a novel population management system for cancer screening

    Science.gov (United States)

    Zai, Adrian H; Kim, Seokjin; Kamis, Arnold; Hung, Ken; Ronquillo, Jeremiah G; Chueh, Henry C; Atlas, Steven J

    2014-01-01

    Objective To optimize a new visit-independent, population-based cancer screening system (TopCare) by using operations research techniques to simulate changes in patient outreach staffing levels (delegates, navigators), modifications to user workflow within the information technology (IT) system, and changes in cancer screening recommendations. Materials and methods TopCare was modeled as a multiserver, multiphase queueing system. Simulation experiments implemented the queueing network model following a next-event time-advance mechanism, in which systematic adjustments were made to staffing levels, IT workflow settings, and cancer screening frequency in order to assess their impact on overdue screenings per patient. Results TopCare reduced the average number of overdue screenings per patient from 1.17 at inception to 0.86 during simulation to 0.23 at steady state. Increases in the workforce improved the effectiveness of TopCare. In particular, increasing the delegate or navigator staff level by one person improved screening completion rates by 1.3% or 12.2%, respectively. In contrast, changes in the amount of time a patient entry stays on delegate and navigator lists had little impact on overdue screenings. Finally, lengthening the screening interval increased efficiency within TopCare by decreasing overdue screenings at the patient level, resulting in a smaller number of overdue patients needing delegates for screening and a higher fraction of screenings completed by delegates. Conclusions Simulating the impact of changes in staffing, system parameters, and clinical inputs on the effectiveness and efficiency of care can inform the allocation of limited resources in population management. PMID:24043318

  13. Information Engineering and Workflow Design in a Clinical Decision Support System for Colorectal Cancer Screening in Iran.

    Science.gov (United States)

    Maserat, Elham; Seied Farajollah, Seiede Sedigheh; Safdari, Reza; Ghazisaeedi, Marjan; Aghdaei, Hamid Asadzadeh; Zali, Mohammad Reza

    2015-01-01

    Colorectal cancer is a major cause of morbidity and mortality throughout the world. Colorectal cancer screening is an optimal way for reducing of morbidity and mortality and a clinical decision support system (CDSS) plays an important role in predicting success of screening processes. DSS is a computer-based information system that improves the delivery of preventive care services. The aim of this article was to detail engineering of information requirements and work flow design of CDSS for a colorectal cancer screening program. In the first stage a screening minimum data set was determined. Developed and developing countries were analyzed for identifying this data set. Then information deficiencies and gaps were determined by check list. The second stage was a qualitative survey with a semi-structured interview as the study tool. A total of 15 users and stakeholders' perspectives about workflow of CDSS were studied. Finally workflow of DSS of control program was designed by standard clinical practice guidelines and perspectives. Screening minimum data set of national colorectal cancer screening program was defined in five sections, including colonoscopy data set, surgery, pathology, genetics and pedigree data set. Deficiencies and information gaps were analyzed. Then we designed a work process standard of screening. Finally workflow of DSS and entry stage were determined. A CDSS facilitates complex decision making for screening and has key roles in designing optimal interactions between colonoscopy, pathology and laboratory departments. Also workflow analysis is useful to identify data reconciliation strategies to address documentation gaps. Following recommendations of CDSS should improve quality of colorectal cancer screening.

  14. Restructuring the Ikeda City school urinary screening system: report of a screening survey

    Science.gov (United States)

    2013-01-01

    Background Annual urinary screening is conducted at municipal kindergartens, elementary schools, and junior high schools in Ikeda City, Osaka, Japan (Ikeda City School System), and the results are reviewed by a general physician, but standards for when to recommend specialist referral have not been clear. Methods In all children attending the Ikeda City School System in 2012, dipstick urinalysis of a first-morning urine specimen was recommended once or twice, and if a second urinalysis showed proteinuria (≥1+), the urinary protein/creatinine ratio was measured. If this showed ≥0.2 g/g of creatinine (g/gCr), it was recommended that the child be evaluated by a specialist at Ikeda City Hospital. Results Urinary screening was performed in about 20% (388) of kindergarten, about 90% (5363) of elementary school, and about 86% (2523) of junior high school children living in Ikeda City. Urine samples were obtained from 387, 5349, and 2476 children, respectively. The urinary protein/creatinine ratio was ≥0.2 g/gCr in 13 children, including 1 elementary and 12 junior high children. In these 13 children, chronic nephritic syndrome (CNS) was suspected in 6 junior high school children, and of these, this was a new finding in 5, and renal biopsy was indicated in 3. In Ikeda City, the prevalence of CNS in elementary school children was junior high school children was 0.29%, and a renal biopsy was indicated in 0.14%. By eliminating the costs associated with assessment of the results by the Ikeda Medical Association, and by directly contracting with the testing company, the expenses paid by Ikeda City for the system itself decreased from 2,508,619 yen to 966,157 yen. Conclusions Incorporating the urinary protein/creatinine ratio into the school urinary screening system in the Ikeda City School System and clarifying standards for specialist referral has enabled restructuring of the system so that is efficient and its effectiveness can be assessed. PMID:24330222

  15. Control system for mapping contaminated areas

    International Nuclear Information System (INIS)

    Milton, Soares; Becker, Paulo H. B.

    2006-01-01

    Some Member states reported to the IAEA an interest in developing a system to be applied in the control of a detector for mapping a surface and defining the distribution of the radioactive material over this area. One of the possible applications would be refurbishment of Rectilinear Scanners (the predecessor of Gamma Cameras) that are old machines but might be still useful for some countries. The IAEA supported this development and a control system for this type of application was designed. in cooperation with the Instituto de Engenharia Nuclear (IEN), Brazil. The system is based on a board developed by the Forschungszentrum Julich in Germany (also in cooperation with the IAEA) and which is based on a Xilinx FPGA SPARTAN XC25150. It contains an MCA (1024 channels based on a fast ADC with software controlled peek detection) and two stepper motor controllers. The human-machine interface developed using Lab View is able to control two stepper motors in order to map an area with a radiation detector. During the mapping the pulse height distributions are collected and an intensity graph for the scanned area is presented on a PC screen. The system was successfully tested using a commercial X-Y table and two commercial stepper motors drivers.. In the next step this system will be used in real applications in the IAEA Member States

  16. Quality control methodology for high-throughput protein-protein interaction screening.

    Science.gov (United States)

    Vazquez, Alexei; Rual, Jean-François; Venkatesan, Kavitha

    2011-01-01

    Protein-protein interactions are key to many aspects of the cell, including its cytoskeletal structure, the signaling processes in which it is involved, or its metabolism. Failure to form protein complexes or signaling cascades may sometimes translate into pathologic conditions such as cancer or neurodegenerative diseases. The set of all protein interactions between the proteins encoded by an organism constitutes its protein interaction network, representing a scaffold for biological function. Knowing the protein interaction network of an organism, combined with other sources of biological information, can unravel fundamental biological circuits and may help better understand the molecular basics of human diseases. The protein interaction network of an organism can be mapped by combining data obtained from both low-throughput screens, i.e., "one gene at a time" experiments and high-throughput screens, i.e., screens designed to interrogate large sets of proteins at once. In either case, quality controls are required to deal with the inherent imperfect nature of experimental assays. In this chapter, we discuss experimental and statistical methodologies to quantify error rates in high-throughput protein-protein interactions screens.

  17. Practical considerations and effects of metallic screen fluorescence and backscatter control in gamma computed radiography

    International Nuclear Information System (INIS)

    Mango, Steven

    2016-01-01

    It is a fairly common misconception that the role of metallic screens used with computed radiography is primarily that of scatter control, and that any amplification of the image signal is minimal. To the contrary, this paper shows how the physical interaction between gamma rays and front metallic screens can yield a significant boost in signal and whether that increased signal is, in fact, beneficial or detrimental to image quality. For rear metallic screens, this signal boost is differentiated from backscatter, and image quality considerations should be more carefully thought out because of the separation between the screen and the imaging layer provided by the imaging plate support. Various physical interactions are explained, and a series of practical experiments show the various changes in signal level and image quality with various thicknesses of lead and copper screens. Recommendations are made for the configuration of the imaging plate and screens for optimum image quality and for the control and monitoring of scatter.

  18. Toward a generalized and high-throughput enzyme screening system based on artificial genetic circuits.

    Science.gov (United States)

    Choi, Su-Lim; Rha, Eugene; Lee, Sang Jun; Kim, Haseong; Kwon, Kilkoang; Jeong, Young-Su; Rhee, Young Ha; Song, Jae Jun; Kim, Hak-Sung; Lee, Seung-Goo

    2014-03-21

    Large-scale screening of enzyme libraries is essential for the development of cost-effective biological processes, which will be indispensable for the production of sustainable biobased chemicals. Here, we introduce a genetic circuit termed the Genetic Enzyme Screening System that is highly useful for high-throughput enzyme screening from diverse microbial metagenomes. The circuit consists of two AND logics. The first AND logic, the two inputs of which are the target enzyme and its substrate, is responsible for the accumulation of a phenol compound in cell. Then, the phenol compound and its inducible transcription factor, whose activation turns on the expression of a reporter gene, interact in the other logic gate. We confirmed that an individual cell harboring this genetic circuit can present approximately a 100-fold higher cellular fluorescence than the negative control and can be easily quantified by flow cytometry depending on the amounts of phenolic derivatives. The high sensitivity of the genetic circuit enables the rapid discovery of novel enzymes from metagenomic libraries, even for genes that show marginal activities in a host system. The crucial feature of this approach is that this single system can be used to screen a variety of enzymes that produce a phenol compound from respective synthetic phenyl-substrates, including cellulase, lipase, alkaline phosphatase, tyrosine phenol-lyase, and methyl parathion hydrolase. Consequently, the highly sensitive and quantitative nature of this genetic circuit along with flow cytometry techniques could provide a widely applicable toolkit for discovering and engineering novel enzymes at a single cell level.

  19. A cloud-based system for automatic glaucoma screening.

    Science.gov (United States)

    Fengshou Yin; Damon Wing Kee Wong; Ying Quan; Ai Ping Yow; Ngan Meng Tan; Gopalakrishnan, Kavitha; Beng Hai Lee; Yanwu Xu; Zhuo Zhang; Jun Cheng; Jiang Liu

    2015-08-01

    In recent years, there has been increasing interest in the use of automatic computer-based systems for the detection of eye diseases including glaucoma. However, these systems are usually standalone software with basic functions only, limiting their usage in a large scale. In this paper, we introduce an online cloud-based system for automatic glaucoma screening through the use of medical image-based pattern classification technologies. It is designed in a hybrid cloud pattern to offer both accessibility and enhanced security. Raw data including patient's medical condition and fundus image, and resultant medical reports are collected and distributed through the public cloud tier. In the private cloud tier, automatic analysis and assessment of colour retinal fundus images are performed. The ubiquitous anywhere access nature of the system through the cloud platform facilitates a more efficient and cost-effective means of glaucoma screening, allowing the disease to be detected earlier and enabling early intervention for more efficient intervention and disease management.

  20. Development of FOODSEYE, a high-speed screening system for radioactivity in foods

    International Nuclear Information System (INIS)

    Mizuta, Tetsuro; Tachibana, Kazushige; Kobayashi, Susumu

    2012-01-01

    We employed the radiation measurement technology utilized for positron emission tomography in nuclear medicine to develop FOODSEYE, a high-speed screening system for radioactivity in food. FOODSEYE enables high-speed screening designed to measure the concentration of radioactive cesium (Bq/kg) in food and determine with a certainty of at least 99% whether a given test article conforms to safety standards established by the Ministry of Health, Labour and Welfare of Japan. The system is comprised of BGO detectors that detect gamma rays with high sensitivity, a shielded construction to reduce noise components from outside sources of radiation (background radiation), a conveyor belt for efficient conveyance of test articles, and a touch screen panel for easy operation and display of results. This design allows the FOODSEYE system to measure trace amounts of radioactivity with high precision. The precision of the system was verified using 30-kg bags of rice tested in Nihonmatsu City in Fukushima Prefecture, Japan. The measurements results obtained with FOODSEYE correlated with, and were within the range of measurement error of, measurement results obtained using a germanium semiconductor detector. The system was also capable of screening one test article per 5 seconds at a standard value of 100 Bq/kg. This article details the system structure, performance and results of verification tests performed using the FOODSEYE high-speed screening system. (author)

  1. [Commentary on the planned restructuring of mammography screening in Austria].

    Science.gov (United States)

    Vutuc, Christian; Haidinger, Gerald

    2011-08-01

    With regards to the planned reorganisation of screening mammography in Austria - from an opportunistic to an organised system - the problems related with such a change are depicted from an epidemiological point of view. We were able to demonstrate earlier that opportunistic screening mammography matches the results of controlled screening mammography in Finland and Sweden. Switching to a controlled system in Austria would - besides the need for a change in legislation - lead to enormous expenditures in terms of resources needed and moreover, it could be not evaluated for years.

  2. Screening for pulmonary arterial hypertension in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    J-L. Vachiéry

    2009-09-01

    Full Text Available The onset and progression of pulmonary arterial hypertension (PAH in patients with systemic sclerosis (SSc can be particularly aggressive; however, effective treatments are available. Therefore, early identification of patients with suspected PAH, confirmation of diagnosis, and intervention is essential. PAH may be challenging to diagnose in its earliest stages, particularly in populations that have multiple causes of breathlessness, and, therefore, screening is required. The optimal screening tools and methodology are, as yet, unknown, and this is confounded by a lack of consensus over which patients to screen. Current practice favours annual screening of all SSc patients using Doppler echocardiography to detect elevated right heart pressures. This will typically identify most patients with the various forms of pulmonary hypertension found in SSc. The optimum thresholds for Doppler echocardiography are still subject to investigation, especially for patients with mild pulmonary hypertension, and this technique may, therefore, yield a significant number of false-positives and a currently unknown number of false-negatives. Confirmatory right heart catheterisation remains necessary in all suspected cases. Further research is needed to identify the optimal tools and the screening approach with greatest specificity and selectivity.

  3. Screening and brief intervention targeting risky drinkers in Danish general practice - a pragmatic controlled trial

    DEFF Research Database (Denmark)

    Beich, A.; Gannik, D.; Saelan, H.

    2007-01-01

    AIMS: Recommendations for routine alcohol screening and brief counselling intervention in primary health care rest on results from intervention efficacy studies. By conducting a pragmatic controlled trial (PCT), we aimed at evaluating the effectiveness of the WHO recommendations for screening......-14 months. Outcome measures focused on patients' acceptance of screening and intervention and their self-reported alcohol consumption. RESULTS: Patient acceptance of screening and intervention -10.3% (N = 794) of the target population (N = 7, 691) explicitly refused screening. All intervention group...

  4. Case-control Studies on the Effectiveness of Breast Cancer Screening: Insights from the UK Age Trial.

    Science.gov (United States)

    van der Waal, Daniëlle; Broeders, Mireille J M; Verbeek, André L M; Duffy, Stephen W; Moss, Sue M

    2015-07-01

    Ongoing breast cancer screening programs can only be evaluated using observational study designs. Most studies have observed a reduction in breast cancer mortality, but design differences appear to have resulted in different estimates. Direct comparison of case-control and trial analyses gives more insight into this variation. Here, we performed case-control analyses within the randomized UK Age Trial. The Age Trial assessed the effect of screening on breast cancer mortality in women ages 40-49 years. In our approach, case subjects were defined as breast cancer deaths between trial entry (1991-1997) and 2004. Women were ages 39-41 years at entry. For every case subject, five control subjects were selected. All case subjects were included in analyses of screening invitation (356 case subjects, 1,780 controls), whereas analyses of attendance were restricted to women invited to screening (105 case subjects, 525 age-matched controls). Odds ratios (OR) were estimated with conditional logistic regression. We used and compared two methods to correct for self-selection bias. Screening invitation resulted in a breast cancer mortality reduction of 17% (95% confidence interval [CI]: -36%, +6%), similar to trial results. Different exposure definitions and self-selection adjustments influenced the observed breast cancer mortality reduction. Depending on the method, "ever screened" appeared to be associated with a small reduction (OR: 0.86, 95% CI: 0.40, 1.89) or no reduction (OR: 1.02, 95% CI: 0.48, 2.14) using the two methods of correction. Recent attendance resulted in an adjusted mortality reduction of 36% (95% CI: -69%, +31%) or 45% (95% CI: -71%, +5%). Observational studies, and particularly case-control studies, are an important monitoring tool for breast cancer screening programs. The focus should be on diminishing bias in observational studies and gaining a better understanding of the influence of study design on estimates of mortality reduction.

  5. Comparing cancer screening estimates: Behavioral Risk Factor Surveillance System and National Health Interview Survey.

    Science.gov (United States)

    Sauer, Ann Goding; Liu, Benmei; Siegel, Rebecca L; Jemal, Ahmedin; Fedewa, Stacey A

    2018-01-01

    Cancer screening prevalence from the Behavioral Risk Factor Surveillance System (BRFSS), designed to provide state-level estimates, and the National Health Interview Survey (NHIS), designed to provide national estimates, are used to measure progress in cancer control. A detailed description of the extent to which recent cancer screening estimates vary by key demographic characteristics has not been previously described. We examined national prevalence estimates for recommended breast, cervical, and colorectal cancer screening using data from the 2012 and 2014 BRFSS and the 2010 and 2013 NHIS. Treating the NHIS estimates as the reference, direct differences (DD) were calculated by subtracting NHIS estimates from BRFSS estimates. Relative differences were computed by dividing the DD by the NHIS estimates. Two-sample t-tests (2-tails), were performed to test for statistically significant differences. BRFSS screening estimates were higher than those from NHIS for breast (78.4% versus 72.5%; DD=5.9%, pNHIS, each survey has a unique and important role in providing information to track cancer screening utilization among various populations. Awareness of these differences and their potential causes is important when comparing the surveys and determining the best application for each data source. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Computer-aided system of evaluation for population-based all-in-one service screening (CASE-PASS): from study design to outcome analysis with bias adjustment.

    Science.gov (United States)

    Chen, Li-Sheng; Yen, Amy Ming-Fang; Duffy, Stephen W; Tabar, Laszlo; Lin, Wen-Chou; Chen, Hsiu-Hsi

    2010-10-01

    Population-based routine service screening has gained popularity following an era of randomized controlled trials. The evaluation of these service screening programs is subject to study design, data availability, and the precise data analysis for adjusting bias. We developed a computer-aided system that allows the evaluation of population-based service screening to unify these aspects and facilitate and guide the program assessor to efficiently perform an evaluation. This system underpins two experimental designs: the posttest-only non-equivalent design and the one-group pretest-posttest design and demonstrates the type of data required at both the population and individual levels. Three major analyses were developed that included a cumulative mortality analysis, survival analysis with lead-time adjustment, and self-selection bias adjustment. We used SAS AF software to develop a graphic interface system with a pull-down menu style. We demonstrate the application of this system with data obtained from a Swedish population-based service screen and a population-based randomized controlled trial for the screening of breast, colorectal, and prostate cancer, and one service screening program for cervical cancer with Pap smears. The system provided automated descriptive results based on the various sources of available data and cumulative mortality curves corresponding to the study designs. The comparison of cumulative survival between clinically and screen-detected cases without a lead-time adjustment are also demonstrated. The intention-to-treat and noncompliance analysis with self-selection bias adjustments are also shown to assess the effectiveness of the population-based service screening program. Model validation was composed of a comparison between our adjusted self-selection bias estimates and the empirical results on effectiveness reported in the literature. We demonstrate a computer-aided system allowing the evaluation of population-based service screening

  7. DIII-D Neutral Beam control system operator interface

    International Nuclear Information System (INIS)

    Harris, J.J.; Campbell, G.L.

    1993-10-01

    A centralized graphical user interface has been added to the DIII-D Neutral Beam (NB) control systems for status monitoring and remote control applications. This user interface provides for automatic data acquisition, alarm detection and supervisory control of the four NB programmable logic controllers (PLC) as well as the Mode Control PLC. These PLCs are used for interlocking, control and status of the NB vacuum pumping, gas delivery, and water cooling systems as well as beam mode status and control. The system allows for both a friendly user interface as well as a safe and convenient method of communicating with remote hardware that formerly required interns to access. In the future, to enable high level of control of PLC subsystems, complete procedures is written and executed at the touch of a screen control panel button. The system consists of an IBM compatible 486 computer running the FIX DMACS trademark for Windows trademark data acquisition and control interface software, a Texas Instruments/Siemens communication card and Phoenix Digital optical communications modules. Communication is achieved via the TIWAY (Texas Instruments protocol link utilizing both fiber optic communications and a copper local area network (LAN). Hardware and software capabilities will be reviewed. Data and alarm reporting, extended monitoring and control capabilities will also be discussed

  8. Rationale and design of the HOME trial: A pragmatic randomized controlled trial of home-based human papillomavirus (HPV) self-sampling for increasing cervical cancer screening uptake and effectiveness in a U.S. healthcare system.

    Science.gov (United States)

    Winer, Rachel L; Tiro, Jasmin A; Miglioretti, Diana L; Thayer, Chris; Beatty, Tara; Lin, John; Gao, Hongyuan; Kimbel, Kilian; Buist, Diana S M

    2018-01-01

    Women who delay or do not attend Papanicolaou (Pap) screening are at increased risk for cervical cancer. Trials in countries with organized screening programs have demonstrated that mailing high-risk (hr) human papillomavirus (HPV) self-sampling kits to under-screened women increases participation, but U.S. data are lacking. HOME is a pragmatic randomized controlled trial set within a U.S. integrated healthcare delivery system to compare two programmatic approaches for increasing cervical cancer screening uptake and effectiveness in under-screened women (≥3.4years since last Pap) aged 30-64years: 1) usual care (annual patient reminders and ad hoc outreach by clinics) and 2) usual care plus mailed hrHPV self-screening kits. Over 2.5years, eligible women were identified through electronic medical record (EMR) data and randomized 1:1 to the intervention or control arm. Women in the intervention arm were mailed kits with pre-paid envelopes to return samples to the central clinical laboratory for hrHPV testing. Results were documented in the EMR to notify women's primary care providers of appropriate follow-up. Primary outcomes are detection and treatment of cervical neoplasia. Secondary outcomes are cervical cancer screening uptake, abnormal screening results, and women's experiences and attitudes towards hrHPV self-sampling and follow-up of hrHPV-positive results (measured through surveys and interviews). The trial was designed to evaluate whether a programmatic strategy incorporating hrHPV self-sampling is effective in promoting adherence to the complete screening process (including follow-up of abnormal screening results and treatment). The objective of this report is to describe the rationale and design of this pragmatic trial. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Active Choice and Financial Incentives to Increase Rates of Screening Colonoscopy-A Randomized Controlled Trial.

    Science.gov (United States)

    Mehta, Shivan J; Feingold, Jordyn; Vandertuyn, Matthew; Niewood, Tess; Cox, Catherine; Doubeni, Chyke A; Volpp, Kevin G; Asch, David A

    2017-11-01

    Behavioral economic approaches could increase uptake for colorectal cancer screening. We performed a randomized controlled trial of 2245 employees to determine whether an email containing a phone number for scheduling (control), an email with the active choice to opt in or opt out (active choice), or the active choice email plus a $100 incentive (financial incentive) increased colonoscopy completion within 3 months. Higher proportions of participants in the financial incentive group underwent screening (3.7%) than in the control (1.6%) or active choice groups (1.5%) (P = .01 and P < .01). We found no difference in uptake of screening between the active choice and control groups (P = .88). The $100 conditional incentive modestly but significantly increased colonoscopy use. ClinicalTrials.gov no: NCT02660671. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. An intervention to preschool children for reducing screen time: a randomized controlled trial.

    Science.gov (United States)

    Yilmaz, G; Demirli Caylan, N; Karacan, C D

    2015-05-01

    Screen time, defined as time spent watching television, DVDs, or videos or playing computer or video games, has been related to serious health consequences in children, such as impaired language acquisition, violent behaviour, tobacco smoking and obesity. Our aim was to determine if a simple intervention aimed at preschool-aged children, applied at the health maintenance visits, in the primary care setting, would be effective in reducing screen time. We used a two group randomized controlled trial design. Two- to 6-year-old children and their parents were randomly assigned to receive an intervention to reduce their screen time, BMI and parental report of aggressive behaviour. At the end of the intervention we made home visits at 2, 6 and 9 months and the parents completed questionnaire. Parents in the intervention group reported less screen time and less aggressive behaviour than those in the control group but there were no differences in BMI z scores. This study shows that a preschool-based intervention can lead to reductions in young children's television/video viewing. © 2014 John Wiley & Sons Ltd.

  11. Non-conventional screening of the Coulomb interaction in low-dimensional and finite-size systems

    NARCIS (Netherlands)

    van den Brink, J.; Sawatzky, G.A.

    2000-01-01

    We study the screening of the Coulomb interaction in non-polar systems by polarizable atoms. We show that in low dimensions and small finite-size systems this screening deviates strongly from that conventionally assumed. In fact in one dimension the short-range interaction is strongly screened and

  12. Screening the working environment in outdoor pig systems.

    Science.gov (United States)

    Geng, Q; Torén, A; Salomon, E

    2009-07-01

    This study investigated how well organic growing-fattening pig systems provided a safe and healthy working environment and identified areas where improvements are needed. The study formed part of a larger project aimed at identifying strategies for creating a good animal and working environment and resource-efficient nutrient management in outdoor pig systems. Field studies were carried out at six Swedish farms in two types of outdoor pig systems (mobile and stationary). A method known as WEST (Work Environment Screening Tool) and a modified version of WEST, called WEST-agriculture (WEST-AG), were utilized for screening. Together, the two methods covered six factors of the working environment. The results were expressed in WEST-AG points and WEST points, an economic measure of the risk of impacts on health and productivity expressed as Swedish Krona (SEK) per thousand working hours. The results demonstrated that the risk of injury and ergonomic load during manual feeding and watering was much higher than during semi-automatic feeding and watering at farms with the mobile system. The study also identified other health-risk areas and provided valuable information for further improvement of the working environment in different outdoor pig systems.

  13. A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Takeshita, E., E-mail: eriuli@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Furukawa, T., E-mail: t_furu@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Inaniwa, T., E-mail: taku@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Sato, S., E-mail: shin_s@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Himukai, T., E-mail: himukai@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Shirai, T., E-mail: t_shirai@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Noda, K., E-mail: noda_k@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan)

    2011-12-15

    A fluorescent screen + a charge coupled device (CCD) system were developed to verify the performance of scanned ion beams at the HIMAC. The fluorescent light from the screen is observed by the CCD camera. Two-dimensional fields, produced by the scanning process, i.e., the position and the size of the beam for each scan, represent of the important issues in scanning irradiation. In the developed system, the two-dimensional relative fluence and the flatness of the irradiation field were measured in a straightforward technique from the luminance distribution on the screen. The position and the size of the beams were obtained from centroid computation results of the brightness. By the good sensitivity and spatial resolution of the fluorescent screen + CCD system, the scanned ion beams were verified as the measurements at the HIMAC prototype scanning system.

  14. A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams

    Science.gov (United States)

    Takeshita, E.; Furukawa, T.; Inaniwa, T.; Sato, S.; Himukai, T.; Shirai, T.; Noda, K.

    2011-12-01

    A fluorescent screen + a charge coupled device (CCD) system were developed to verify the performance of scanned ion beams at the HIMAC. The fluorescent light from the screen is observed by the CCD camera. Two-dimensional fields, produced by the scanning process, i.e., the position and the size of the beam for each scan, represent of the important issues in scanning irradiation. In the developed system, the two-dimensional relative fluence and the flatness of the irradiation field were measured in a straightforward technique from the luminance distribution on the screen. The position and the size of the beams were obtained from centroid computation results of the brightness. By the good sensitivity and spatial resolution of the fluorescent screen + CCD system, the scanned ion beams were verified as the measurements at the HIMAC prototype scanning system.

  15. A comparison of the performance of modern screen-film and digital mammography systems

    Energy Technology Data Exchange (ETDEWEB)

    Monnin, P [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Gutierrez, D [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Bulling, S [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Lepori, D [Department of Radiology, University Hospital Center (CHUV), CH-1011 Lausanne (Switzerland); Valley, J-F [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Verdun, F R [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland)

    2005-06-07

    This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.

  16. Web-based newborn screening system for metabolic diseases: machine learning versus clinicians.

    Science.gov (United States)

    Chen, Wei-Hsin; Hsieh, Sheau-Ling; Hsu, Kai-Ping; Chen, Han-Ping; Su, Xing-Yu; Tseng, Yi-Ju; Chien, Yin-Hsiu; Hwu, Wuh-Liang; Lai, Feipei

    2013-05-23

    A hospital information system (HIS) that integrates screening data and interpretation of the data is routinely requested by hospitals and parents. However, the accuracy of disease classification may be low because of the disease characteristics and the analytes used for classification. The objective of this study is to describe a system that enhanced the neonatal screening system of the Newborn Screening Center at the National Taiwan University Hospital. The system was designed and deployed according to a service-oriented architecture (SOA) framework under the Web services .NET environment. The system consists of sample collection, testing, diagnosis, evaluation, treatment, and follow-up services among collaborating hospitals. To improve the accuracy of newborn screening, machine learning and optimal feature selection mechanisms were investigated for screening newborns for inborn errors of metabolism. The framework of the Newborn Screening Hospital Information System (NSHIS) used the embedded Health Level Seven (HL7) standards for data exchanges among heterogeneous platforms integrated by Web services in the C# language. In this study, machine learning classification was used to predict phenylketonuria (PKU), hypermethioninemia, and 3-methylcrotonyl-CoA-carboxylase (3-MCC) deficiency. The classification methods used 347,312 newborn dried blood samples collected at the Center between 2006 and 2011. Of these, 220 newborns had values over the diagnostic cutoffs (positive cases) and 1557 had values that were over the screening cutoffs but did not meet the diagnostic cutoffs (suspected cases). The original 35 analytes and the manifested features were ranked based on F score, then combinations of the top 20 ranked features were selected as input features to support vector machine (SVM) classifiers to obtain optimal feature sets. These feature sets were tested using 5-fold cross-validation and optimal models were generated. The datasets collected in year 2011 were used as

  17. Efficacy of computer-aided detection system for screening mammography

    International Nuclear Information System (INIS)

    Saito, Mioko; Ohnuki, Koji; Yamada, Takayuki; Saito, Haruo; Ishibashi, Tadashi; Ohuchi, Noriaki; Takahashi, Shoki

    2002-01-01

    A study was conducted to evaluate the efficacy of a computer-aided detection (CAD) system for screening mammography (MMG). Screening mammograms of 2,231 women aged over 50 yr were examined. Medio-lateral oblique (MLO) images were obtained, and two expert observers interpreted the mammograms by consensus. First, each mammogram was interpreted without the assistance of CAD, followed immediately by a re-evaluation of areas marked by the CAD system. Data were recorded to measure the effect of CAD on the recall rate, cancer detection rate and detection rate of masses, microcalcifications and other findings. The CAD system increased the recall rate from 2.3% to 2.6%. Six recalled cases were diagnosed as breast cancer pathologically, and CAD detected all of these lesions. Seven additional cases in which CAD detected abnormal findings had no malignancy. The detection rate of CAD for microcalcifications was high (95.0%). However, the detection rate for mass lesions and other findings was low (29.2% and 25.0% respectively). The false positivity rate was 0.13/film for microcalcifications, and 0.25/film for mass lesions. The efficacy of the CAD system for detecting microcalcifications on screening mammograms was confirmed. However, the low detection rate of mass lesions and relatively high rate of false positivity need to be further improved. (author)

  18. The genetic origins of biosynthesis and light-responsive control of the chemical UV screen of land plants

    International Nuclear Information System (INIS)

    Jorgensen, R.

    1994-01-01

    Most land plants possess the capacity to protect themselves from UV light, and do so by producing pigments that absorb efficiently in the UV-A and UV-B regions of the spectrum while allowing transmission of nearly all photosynthetically useful wavelengths. These UV-absorbing pigments are mainly phenylpropanoids and flavonoids. This chapter summarizes current understanding of the mechanism of UV protection in higher land plants, evaluates the information available from lower land plants and their green-algal relatives, and then considers the possible evolutionary origins of this use of chemical filters for selectively screening UV light from solar radiation. It is proposed that photo control over the biosynthesis of UV-absorbing phenylpropanoids and flavonoids may have evolved in concert with the evolution of the high biosynthetic activity necessary for UV protection. The toxicity of phenylpropanoids and flavonoids has been postulated to have been a barrier to the evolution of an effective chemical UV screen, and that some means for sequestering these compounds and/or for controlling their synthesis probably evolved prior to, or in concert with, the evolution of high rates of biosynthesis. The original photoreceptor and signal transduction system is speculated to have been based on photo isomerization of a phenylpropanoid ester and a pre-existing product feedback mechanism for controlling phenylpropanoid biosynthesis. Understanding the original mechanism for photo control of the chemical UV screen of land plants could be valuable for understanding the adaptability of extant land plants to rising levels of solar UV-B radiation and may suggest genetic strategies for engineering improved UV tolerance in crop plants. (author)

  19. Efficient high-throughput biological process characterization: Definitive screening design with the ambr250 bioreactor system.

    Science.gov (United States)

    Tai, Mitchell; Ly, Amanda; Leung, Inne; Nayar, Gautam

    2015-01-01

    The burgeoning pipeline for new biologic drugs has increased the need for high-throughput process characterization to efficiently use process development resources. Breakthroughs in highly automated and parallelized upstream process development have led to technologies such as the 250-mL automated mini bioreactor (ambr250™) system. Furthermore, developments in modern design of experiments (DoE) have promoted the use of definitive screening design (DSD) as an efficient method to combine factor screening and characterization. Here we utilize the 24-bioreactor ambr250™ system with 10-factor DSD to demonstrate a systematic experimental workflow to efficiently characterize an Escherichia coli (E. coli) fermentation process for recombinant protein production. The generated process model is further validated by laboratory-scale experiments and shows how the strategy is useful for quality by design (QbD) approaches to control strategies for late-stage characterization. © 2015 American Institute of Chemical Engineers.

  20. CDC Screening Recommendation for Baby Boomers and Hepatitis C Virus Testing in the US Military Health System.

    Science.gov (United States)

    Manjelievskaia, Janna; Brown, Derek; Shriver, Craig D; Zhu, Kangmin

    Chronic hepatitis C virus (HCV) is the most common blood-borne infection in the United States, with an estimated 2.7 to 3.9 million cases as of 2014. In August 2012, the Centers for Disease Control and Prevention (CDC) recommended 1-time HCV testing of all baby boomers. The objectives of this study were to (1) determine the proportion of people screened for HCV in the US Department of Defense Military Health System before and after the CDC screening recommendation for baby boomers and (2) assess whether certain patient or system factors were associated with screening for HCV before and after August 2012. We used a dataset containing 5% of beneficiaries randomly selected from the Military Health System Data Repository medical claims database for the period July 2011 through September 2013. Of 108 223 people eligible for HCV screening during the first period (July 2011 through July 2012), 1812 (1.7%) were screened. Of 109 768 people eligible during the second period (September 2012 through September 2013), 2599 (2.4%) were screened. HCV screening receipt was related to benefit type (Prime before August 2012: adjusted odds ratio [aOR] = 2.16; 95% confidence interval [CI], 1.89-2.46; Prime after August 2012: aOR = 1.93; 95% CI, 1.73-2.16) and care source (direct care before August 2012: aOR = 1.80; 95% CI, 1.57-2.07; direct care after August 2012: aOR = 2.45; 95% CI, 2.18-2.75); male sex (aOR = 1.17; 95% CI, 1.06-1.29) and black race (aOR = 1.20; 95% CI, 1.05-1.37) were associated with HCV testing only before August 2012. Interventions should be implemented to increase awareness and knowledge of the current national HCV testing recommendation among baby boomers to seek out testing and health care providers to perform screening.

  1. Status of the CMS Detector Control System

    CERN Document Server

    Bauer, Gerry; Bouffet, Olivier; Bowen, Matthew; Branson, James G; Bukowiec, Sebastian; Ciganek, Marek; Cittolin, Sergio; Jose Antonio Coarasa; Deldicque, Christian; Dobson, Marc; Dupont, Aymeric; Erhan, Samim; Flossdorf, Alexander; Gigi, Dominique; Glege, Frank; Gomez-Reino, Robert; Hartl, Christian; Hegeman, Jeroen; Holzner, André; Yi Ling Hwong; Masetti, Lorenzo; Meijers, Frans; Meschi, Emilio; Mommsen, Remigius K; O'Dell, Vivian; Orsini, Luciano; Paus, Christoph; Petrucci, Andrea; Pieri, Marco; Polese, Giovanni; Racz, Attila; Raginel, Olivier; Sakulin, Hannes; Sani, Matteo; Schwick, Christoph; Shpakov, Dennis; Simon, Michal; Andrei Cristian Spataru; Sumorok, Konstanty

    2012-01-01

    The Compact Muon Solenoid (CMS) is a CERN multi-purpose experiment that exploits the physics of the Large Hadron Collider (LHC). The Detector Control System (DCS) ensures a safe, correct and efficient experiment operation, contributing to the recording of high quality physics data. The DCS is programmed to automatically react to the LHC operational mode. CMS sub-detectors' bias voltages are set depending on the machine mode and particle beam conditions. An operator provided with a small set of screens supervises the system status summarized from the approximately 6M monitored parameters. Using the experience of nearly two years of operation with beam the DCS automation software has been enhanced to increase the system efficiency by minimizing the time required by sub detectors to prepare for physics data taking. From the infrastructure point of view the DCS will be subject to extensive modifications in 2012. The current rack mounted control PCs will be exchanged by a redundant pair of DELL Blade systems. Thes...

  2. Possibilities and expectations for improved man-machine interface in power system control

    Energy Technology Data Exchange (ETDEWEB)

    Asal, H; Burrow, R K; Lindstrom, K; Mocenigo, M; Schellstede, G; Schaffer, G; Serrani, A

    1992-05-01

    The paper describes the hardware, equipment and functions provided to operators for supervising and controlling HVAC power systems. It analyzes the main elements of the man-machine interface (MMI) with particular attention to the recent possibilities afforded by computer technology and full graphic screens. Alarm management and remote control operation are briefly described.

  3. Control software architecture and operating modes of the Model M-2 maintenance system

    Energy Technology Data Exchange (ETDEWEB)

    Satterlee, P.E. Jr.; Martin, H.L.; Herndon, J.N.

    1984-04-01

    The Model M-2 maintenance system is the first completely digitally controlled servomanipulator. The M-2 system allows dexterous operations to be performed remotely using bilateral force-reflecting master/slave techniques, and its integrated operator interface takes advantage of touch-screen-driven menus to allow selection of all possible operating modes. The control system hardware for this system has been described previously. This paper describes the architecture of the overall control system. The system's various modes of operation are identified, the software implementation of each is described, system diagnostic routines are described, and highlights of the computer-augmented operator interface are discussed. 3 references, 5 figures.

  4. Control software architecture and operating modes of the Model M-2 maintenance system

    International Nuclear Information System (INIS)

    Satterlee, P.E. Jr.; Martin, H.L.; Herndon, J.N.

    1984-04-01

    The Model M-2 maintenance system is the first completely digitally controlled servomanipulator. The M-2 system allows dexterous operations to be performed remotely using bilateral force-reflecting master/slave techniques, and its integrated operator interface takes advantage of touch-screen-driven menus to allow selection of all possible operating modes. The control system hardware for this system has been described previously. This paper describes the architecture of the overall control system. The system's various modes of operation are identified, the software implementation of each is described, system diagnostic routines are described, and highlights of the computer-augmented operator interface are discussed. 3 references, 5 figures

  5. Ergonomic problems regarding the interactive touch input via screens in onboard and ground-based flight control

    Science.gov (United States)

    Holzhausen, K. P.; Gaertner, K. P.

    1985-01-01

    A significant problem concerning the integration of display and switching functions is related to the fact that numerous informative data which have to be processed by man must be read from only a few display devices. A satisfactory ergonomic design of integrated display devices and keyboards is in many cases difficult, because not all functions which can be displayed and selected are simultaneously available. A technical solution which provides an integration of display and functional elements on the basis of the highest flexibility is obtained by using a cathode ray tube with a touch-sensitive screen. The employment of an integrated data input/output system is demonstrated for the cases of onboard and ground-based flight control. Ergonomic studies conducted to investigate the suitability of an employment of touch-sensitive screens are also discussed.

  6. Results of clinical and radiologic mass-screening tests of the locomotor system of miners in Hungary

    Energy Technology Data Exchange (ETDEWEB)

    Bene, E.; Temesvary, P.; Szilagyi, M.; Pera, F.

    Clinical and radiological screening tests on the locomotor system of 250 workers being active in mines were accomplished by the authors. The test results of 125 miners working underground were compared with those of a control group consisting of equally 125 workers of the same age category, but engaged in open mining. As a result of the investigation it could be stated that miners working in underground mines were affected by diseases of the organs of motion at a very early stage, and in a greater proportion. The most serious deformations were observed with development irregularities and development variations. The development of degenerative locomotor diseases is promoted in Hungary by the working conditions prevailing underground. The completion of the examination procedure of fitness for work by clinical and radiological examinations of the locomotor system is important and highly recommended. The investigation carried out by the authors may serve as a model for the screening tests to be made on the locomotor system of industrial workers.

  7. Electron beam accelerator energy control system

    International Nuclear Information System (INIS)

    Sharma, Vijay; Rajan, Rehim; Acharya, S.; Mittal, K.C.

    2011-01-01

    A control system has been developed for the energy control of the electron beam accelerator using PLC. The accelerating voltage of 3 MV has been obtained by using parallel coupled voltage multiplier circuit. A autotransformer controlled variable 0-10 KV DC is fed to a tube based push pull oscillator to generate 120 Khz, 10 KV AC. Oscillator output voltage is stepped up to 0-300 KV/AC using a transformer. 0-300 KVAC is fed to the voltage multiplier column to generate the accelerating voltage at the dome 0-3 MV/DC. The control system has been designed to maintain the accelerator voltage same throughout the operation by adjusting the input voltage in close loop. Whenever there is any change in the output voltage either because of beam loading or arcing in the accelerator. The instantaneous accelerator voltage or energy is a direct proportional to 0-10 KVDC obtained from autotransformer. A PLC based control system with user settable energy level has been installed for 3 MeV, EB accelerator. The PLC takes the user defined energy value through a touch screen and compares it to the actual accelerating voltage (obtained using resistive divider). Depending upon the error the PLC generates the pulses to adjust the autotransformer to bring the actual voltage to the set value within the window of error (presently set to +/- 0.1%). (author)

  8. Ovarian cancer screening and mortality in the UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS): a randomised controlled trial

    Science.gov (United States)

    Jacobs, Ian J; Menon, Usha; Ryan, Andy; Gentry-Maharaj, Aleksandra; Burnell, Matthew; Kalsi, Jatinderpal K; Amso, Nazar N; Apostolidou, Sophia; Benjamin, Elizabeth; Cruickshank, Derek; Crump, Danielle N; Davies, Susan K; Dawnay, Anne; Dobbs, Stephen; Fletcher, Gwendolen; Ford, Jeremy; Godfrey, Keith; Gunu, Richard; Habib, Mariam; Hallett, Rachel; Herod, Jonathan; Jenkins, Howard; Karpinskyj, Chloe; Leeson, Simon; Lewis, Sara J; Liston, William R; Lopes, Alberto; Mould, Tim; Murdoch, John; Oram, David; Rabideau, Dustin J; Reynolds, Karina; Scott, Ian; Seif, Mourad W; Sharma, Aarti; Singh, Naveena; Taylor, Julie; Warburton, Fiona; Widschwendter, Martin; Williamson, Karin; Woolas, Robert; Fallowfield, Lesley; McGuire, Alistair J; Campbell, Stuart; Parmar, Mahesh; Skates, Steven J

    2016-01-01

    Summary Background Ovarian cancer has a poor prognosis, with just 40% of patients surviving 5 years. We designed this trial to establish the effect of early detection by screening on ovarian cancer mortality. Methods In this randomised controlled trial, we recruited postmenopausal women aged 50–74 years from 13 centres in National Health Service Trusts in England, Wales, and Northern Ireland. Exclusion criteria were previous bilateral oophorectomy or ovarian malignancy, increased risk of familial ovarian cancer, and active non-ovarian malignancy. The trial management system confirmed eligibility and randomly allocated participants in blocks of 32 using computer-generated random numbers to annual multimodal screening (MMS) with serum CA125 interpreted with use of the risk of ovarian cancer algorithm, annual transvaginal ultrasound screening (USS), or no screening, in a 1:1:2 ratio. The primary outcome was death due to ovarian cancer by Dec 31, 2014, comparing MMS and USS separately with no screening, ascertained by an outcomes committee masked to randomisation group. All analyses were by modified intention to screen, excluding the small number of women we discovered after randomisation to have a bilateral oophorectomy, have ovarian cancer, or had exited the registry before recruitment. Investigators and participants were aware of screening type. This trial is registered with ClinicalTrials.gov, number NCT00058032. Findings Between June 1, 2001, and Oct 21, 2005, we randomly allocated 202 638 women: 50 640 (25·0%) to MMS, 50 639 (25·0%) to USS, and 101 359 (50·0%) to no screening. 202 546 (>99·9%) women were eligible for analysis: 50 624 (>99·9%) women in the MMS group, 50 623 (>99·9%) in the USS group, and 101 299 (>99·9%) in the no screening group. Screening ended on Dec 31, 2011, and included 345 570 MMS and 327 775 USS annual screening episodes. At a median follow-up of 11·1 years (IQR 10·0–12·0), we diagnosed ovarian cancer in

  9. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    Science.gov (United States)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  10. Pulse Oximetry Screening Adapted to a System with Home Births: The Dutch Experience

    Directory of Open Access Journals (Sweden)

    Ilona C. Narayen

    2018-03-01

    Full Text Available Neonatal screening for critical congenital heart defects is proven to be safe, accurate, and cost-effective. The screening has been implemented in many countries across all continents in the world. However, screening for critical congenital heart defects after home births had not been studied widely yet. The Netherlands is known for its unique perinatal care system with a high rate of home births (18% and early discharge after an uncomplicated delivery in hospital. We report a feasibility, accuracy, and acceptability study performed in the Dutch perinatal care system. Screening newborns for critical congenital heart defects using pulse oximetry is feasible after home births and early discharge, and acceptable to mothers. The accuracy of the test is comparable to other early-screening settings, with a moderate sensitivity and high specificity.

  11. Depression screening optimization in an academic rural setting.

    Science.gov (United States)

    Aleem, Sohaib; Torrey, William C; Duncan, Mathew S; Hort, Shoshana J; Mecchella, John N

    2015-01-01

    Primary care plays a critical role in screening and management of depression. The purpose of this paper is to focus on leveraging the electronic health record (EHR) as well as work flow redesign to improve the efficiency and reliability of the process of depression screening in two adult primary care clinics of a rural academic institution in USA. The authors utilized various process improvement tools from lean six sigma methodology including project charter, swim lane process maps, critical to quality tree, process control charts, fishbone diagrams, frequency impact matrix, mistake proofing and monitoring plan in Define-Measure-Analyze-Improve-Control format. Interventions included change in depression screening tool, optimization of data entry in EHR. EHR data entry optimization; follow up of positive screen, staff training and EHR redesign. Depression screening rate for office-based primary care visits improved from 17.0 percent at baseline to 75.9 percent in the post-intervention control phase (p<0.001). Follow up of positive depression screen with Patient History Questionnaire-9 data collection remained above 90 percent. Duplication of depression screening increased from 0.6 percent initially to 11.7 percent and then decreased to 4.7 percent after optimization of data entry by patients and flow staff. Impact of interventions on clinical outcomes could not be evaluated. Successful implementation, sustainability and revision of a process improvement initiative to facilitate screening, follow up and management of depression in primary care requires accounting for voice of the process (performance metrics), system limitations and voice of the customer (staff and patients) to overcome various system, customer and human resource constraints.

  12. Screening, Aharonov - Bohm effect, and linking number in spin systems

    International Nuclear Information System (INIS)

    Borisenko, O.; Petrov, K.; Faber, M.

    2000-01-01

    Screening mechanisms and related effects are studied in a variety of spin systems coupled to an external magnetic field. We use a special order parameter which can distinguish between screening due to the kinetic energy of spin excitations and screening due to the magnetic field. The action of this order parameter is based on an analog of the Aharonov - Bohm (AB) effect. The order parameter may test the realization of discrete symmetries embedded into the group symmetry of the theory via probing a nontrivial discrete charge. As simple examples, we study the Gaussian and Ising models. For the latter, we performed also Monte-Carlo simulations for a constant magnetic field. We then apply our results to spin systems with abelian and nonabelian global symmetries in two dimensions and argue that the order parameter proposed could serve as a tool to detect the Berezinskii - Kosterlitz - Thouless (BKT) phase transition

  13. Impact of organised mammography screening on breast cancer mortality in a case–control and cohort study

    Science.gov (United States)

    Heinävaara, Sirpa; Sarkeala, Tytti; Anttila, Ahti

    2016-01-01

    Background: The usefulness of case–control studies has been questioned. Our aim was to evaluate the long-term effect of screening on breast cancer mortality within the population-based mammography programme in Finland using a case–control design, and to compare the analyses with the earlier cohort study. Methods: The cases were women invited to screening, diagnosed and died from breast cancer in 1992–2011 while being 50–84 years at death. We chose 10 controls for each case with non-restrictive eligibility criteria. Our data included 1907 cases and 18 978 matched controls. We analysed associations between the screening participation and the risk of breast cancer death using the conditional Cox proportional hazards model. The effect estimates were corrected for self-selection bias. Results: An overall effect of screening was 0.67 (95% confidence interval (CI): 0.49–0.90), and that remained unchanged over time. Analyses with matching criteria comparable to the cohort study yielded an effect (0.70, 95% CI: 0.49–1.00) in 1992–2003 similar to that of the previous cohort analysis (0.72, 95% CI: 0.56–0.88). Conclusions: Organised mammography screening decreases mortality from breast cancer by 33% among the participants. If made comparable, a case–cohort study can yield effect estimates similar to a cohort study. PMID:27010748

  14. Randomized controlled dissemination study of community-to-clinic navigation to promote CRC screening: Study design and implications.

    Science.gov (United States)

    Larkey, Linda; Szalacha, Laura; Herman, Patricia; Gonzalez, Julie; Menon, Usha

    2017-02-01

    Regular screening facilitates early diagnosis of colorectal cancer (CRC) and reduction of CRC morbidity and mortality. Screening rates for minorities and low-income populations remain suboptimal. Provider referral for CRC screening is one of the strongest predictors of adherence, but referrals are unlikely among those who have no clinic home (common among poor and minority populations). This group randomized controlled study will test the effectiveness of an evidence based tailored messaging intervention in a community-to-clinic navigation context compared to no navigation. Multicultural, underinsured individuals from community sites will be randomized (by site) to receive CRC screening education only, or education plus navigation. In Phase I, those randomized to education plus navigation will be guided to make a clinic appointment to receive a provider referral for CRC screening. Patients attending clinic appointments will continue to receive navigation until screened (Phase II) regardless of initial arm assignment. We hypothesize that those receiving education plus navigation will be more likely to attend clinic appointments (H1) and show higher rates of screening (H2) compared to those receiving education only. Phase I group assignment will be used as a control variable in analysis of screening follow-through in Phase II. Costs per screening achieved will be evaluated for each condition and the RE-AIM framework will be used to examine dissemination results. The novelty of our study design is the translational dissemination model that will allow us to assess the real-world application of an efficacious intervention previously tested in a randomized controlled trial. Copyright © 2016. Published by Elsevier Inc.

  15. Engineering evaluation of porous-dike intake screening systems

    International Nuclear Information System (INIS)

    Roberge, J.C.

    1978-01-01

    As one of many concepts currently under investigation for use in screening fish and larvae from power plant intakes, the porous-dike system presents unique challenges to the designer and constructor. A complete understanding of the hydraulic losses through such a structure is necessary to properly size and locate the intake and to ensure proper pump selection and performance. In the study described in this report, an analogy with frictional losses in conduits was employed, and empirical data on losses were determined for three sizes of filter stone typical of the types used in the construction of a porous-dike intake system. These empirical data were compared with additional information from the literature. The dependence of hydraulic losses through large-diameter media on stone shape and porosity were demonstrated although no empirical expression of this dependence was developed. A hypothetical porous-dike intake installation was developed, demonstrating the fundamental design considerations which must be made for such a structure. Finally, a cursory economic comparison of various intake screening systems demonstrated that the porous-dike intake concept was economically competitive with all others

  16. A randomized controlled trial of a multilevel intervention to increase colorectal cancer screening among Latino immigrants in a primary care facility.

    Science.gov (United States)

    Aragones, Abraham; Schwartz, Mark D; Shah, Nirav R; Gany, Francesca M

    2010-06-01

    Latino immigrants face a higher burden of colorectal cancer (CRC) and screening rates are low. To assess the effectiveness of a multilevel intervention in increasing the rate of CRC screening among Latino immigrants. A randomized controlled trial, with randomization at the physician level. Pairs of 65 primary care physicians and 65 Latino immigrant patients participated, 31 in the intervention and 34 in the control group. CRC educational video in Spanish on a portable personal digital video display device accompanied by a brochure with key information for the patient, and a patient-delivered paper-based reminder for their physician. Completed CRC screening, physician recommendation for CRC screening, and patient adherence to physician recommended CRC screening. The overall rate of completed screening for CRC was 55% for the intervention and 18% for the control group (p = 0.002). Physicians recommended CRC screening for 61% of patients in the intervention group versus 41% in the control group (p = 0.08). Of those that received a recommendation, 90% in the intervention group adhered to it versus 26% in the control group (p = 0.007). The intervention was successful in increasing rates of completed CRC screening primarily through increasing adherence after screening was recommended. Additional efforts should focus on developing new strategies to increase physician recommendation for CRC screening, while employing effective patient adherence interventions.

  17. A microliter-scale high-throughput screening system with quantum-dot nanoprobes for amyloid-β aggregation inhibitors.

    Directory of Open Access Journals (Sweden)

    Yukako Ishigaki

    Full Text Available The aggregation of amyloid β protein (Aβ is a key step in the pathogenesis of Alzheimer's disease (AD, and therefore inhibitory substances for Aβ aggregation may have preventive and/or therapeutic potential for AD. Here we report a novel microliter-scale high-throughput screening system for Aβ aggregation inhibitors based on fluorescence microscopy-imaging technology with quantum-dot Nanoprobes. This screening system could be analyzed with a 5-µl sample volume when a 1536-well plate was used, and the inhibitory activity could be estimated as half-maximal effective concentrations (EC50. We attempted to comprehensively screen Aβ aggregation inhibitors from 52 spices using this system to assess whether this novel screening system is actually useful for screening inhibitors. Screening results indicate that approximately 90% of the ethanolic extracts from the spices showed inhibitory activity for Aβ aggregation. Interestingly, spices belonging to the Lamiaceae, the mint family, showed significantly higher activity than the average of tested spices. Furthermore, we tried to isolate the main inhibitory compound from Saturejahortensis, summer savory, a member of the Lamiaceae, using this system, and revealed that the main active compound was rosmarinic acid. These results demonstrate that this novel microliter-scale high-throughput screening system could be applied to the actual screening of Aβ aggregation inhibitors. Since this system can analyze at a microscopic scale, it is likely that further minimization of the system would easily be possible such as protein microarray technology.

  18. Development of a visual control and display system for the SMART plant analyzer

    International Nuclear Information System (INIS)

    Kang, Han Ok; Yoon, Ju Hyeon; Seo, Jae Kwang; Lee, Doo Jeong

    2000-01-01

    A Visual Control and Display System (VCDS) for the SMART plant analyzer has been developed using the MMS simulation tools. The SAMRT plant analyzer consists of the VCDS and the MMS SMART model. The MMS SMART model is a numerical simulation model for the SMART plant and is composed of the MMS real-time modules and control blocks. It covers the whole plant including primary, secondary and auxiliary systems. The developed VCDS is Graphical User Interfaces (GUI) that is running in a synchronized way with the SMART model. The VCDS consists of the MMS Simulation tools and seven control and display screens. The VCDS provides easy means for the control and display of the SMART model status. The VCDS allows users to display and change a specified list of model variables and transient scenarios interactively through the MMS simulation tools. The control and display screens are developed with Visual Basic 6.0 and MMI32 ActiveX controls and it can be executed in several TCP/IP networked computers simultaneously. The developed VCDS can be utilized for the engineering simulation of the SMART plant operation, and for control logic and operational procedure developments

  19. Method for screening prevention and control measures and technologies based on groundwater pollution intensity assessment.

    Science.gov (United States)

    Li, Juan; Yang, Yang; Huan, Huan; Li, Mingxiao; Xi, Beidou; Lv, Ningqing; Wu, Yi; Xie, Yiwen; Li, Xiang; Yang, Jinjin

    2016-05-01

    This paper presents a system for determining the evaluation and gradation indices of groundwater pollution intensity (GPI). Considering the characteristics of the vadose zone and pollution sources, the system decides which anti-seepage measures should be implemented at the contaminated site. The pollution sources hazards (PSH) and groundwater intrinsic vulnerability (GIV) are graded by the revised Nemerow Pollution Index and an improved DRTAS model, respectively. GPI is evaluated and graded by a double-sided multi-factor coupling model, which is constructed by the matrix method. The contaminated sites are categorized as prior, ordinary, or common sites. From the GPI results, we develop guiding principles for preventing and removing pollution sources, procedural interruption and remediation, and end treatment and monitoring. Thus, we can select appropriate prevention and control technologies (PCT). To screen the technological schemes and optimize the traditional analytical hierarchy process (AHP), we adopt the technique for order preference by the similarity to ideal solution (TOPSIS) method. Our GPI approach and PCT screening are applied to three types of pollution sites: the refuse dump of a rare earth mine development project (a potential pollution source), a chromium slag dump, and a landfill (existing pollution sources). These three sites are identified as ordinary, prior, and ordinary sites, respectively. The anti-seepage materials at the refuse dump should perform as effectively as a 1.5-m-thick clay bed. The chromium slag dump should be preferentially treated by soil flushing and in situ chemical remediation. The landfill should be treated by natural attenuation technology. The proposed PCT screening approach was compared with conventional screening methods results at the three sites and proved feasible and effective. The proposed method can provide technical support for the monitoring and management of groundwater pollution in China. Copyright © 2015

  20. A Network and Visual Quality Aware N-Screen Content Recommender System Using Joint Matrix Factorization

    Directory of Open Access Journals (Sweden)

    Farman Ullah

    2014-01-01

    Full Text Available We propose a network and visual quality aware N-Screen content recommender system. N-Screen provides more ways than ever before to access multimedia content through multiple devices and heterogeneous access networks. The heterogeneity of devices and access networks present new questions of QoS (quality of service in the realm of user experience with content. We propose, a recommender system that ensures a better visual quality on user’s N-screen devices and the efficient utilization of available access network bandwidth with user preferences. The proposed system estimates the available bandwidth and visual quality on users N-Screen devices and integrates it with users preferences and contents genre information to personalize his N-Screen content. The objective is to recommend content that the user’s N-Screen device and access network are capable of displaying and streaming with the user preferences that have not been supported in existing systems. Furthermore, we suggest a joint matrix factorization approach to jointly factorize the users rating matrix with the users N-Screen device similarity and program genres similarity. Finally, the experimental results show that we also enhance the prediction and recommendation accuracy, sparsity, and cold start issues.

  1. A network and visual quality aware N-screen content recommender system using joint matrix factorization.

    Science.gov (United States)

    Ullah, Farman; Sarwar, Ghulam; Lee, Sungchang

    2014-01-01

    We propose a network and visual quality aware N-Screen content recommender system. N-Screen provides more ways than ever before to access multimedia content through multiple devices and heterogeneous access networks. The heterogeneity of devices and access networks present new questions of QoS (quality of service) in the realm of user experience with content. We propose, a recommender system that ensures a better visual quality on user's N-screen devices and the efficient utilization of available access network bandwidth with user preferences. The proposed system estimates the available bandwidth and visual quality on users N-Screen devices and integrates it with users preferences and contents genre information to personalize his N-Screen content. The objective is to recommend content that the user's N-Screen device and access network are capable of displaying and streaming with the user preferences that have not been supported in existing systems. Furthermore, we suggest a joint matrix factorization approach to jointly factorize the users rating matrix with the users N-Screen device similarity and program genres similarity. Finally, the experimental results show that we also enhance the prediction and recommendation accuracy, sparsity, and cold start issues.

  2. Value of the asymmetric film-screen system InSight HC in chest imaging

    International Nuclear Information System (INIS)

    Haeussler, M.D.; Lenzen, H.; Reckels, C.; Peters, P.E.

    1994-01-01

    The asymmetric film-screen system InSight HC represents a development to optimize chest imaging. The purpose of the study was to compare the exposure range and the image quality of this new system with a conventional film-screen system. The optical density of images in both techniques was measured and the image quality of 100 chest images from 50 intensive-care patients was evaluated. 4 observers graded the image quality of organic, non-organic and pathological structures. Statistical evaluation was performed by interobserver analysis. The asymmetric film-screen system shows a larger exposure range and a superior image quality in the mediastinal field. The image quality in the peripheral field must be judged critically and improved especially because of the poor recognizability of pneumothoraces. (orig.) [de

  3. New screening system for unruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Samejima, Hirotsugu; Ushikubo, Yukio; Mizokami, Toru

    1990-01-01

    We have designed a screening system to diagnose unruptured aneurysms, including the use of digital subtraction angiography (DSA). We surveyed 115 patients who had undergone clipping procedures after subarachnoid hemorrhage (SAH) and questioned them with regard to the subjective symptoms. Sixty-eight of 92 patients who returned the questionnaire reported, prior to rupture, headache,eye pain, and neck pain most frequently, and also impairment of extraocular movements, ptosis, visual field defects, and motor and sensory disturbances. Nineteen (47.5%) of 40 patients who had complete pain relief after surgery complained of headache from 1 week to 1 month before SAH. In addition, nine patients (22.5%) complained of headache for several years, and were also pain-free after surgery. For the indication of DSA, we employed an expert system based on fuzzy set theory. Seven groups of parameters are: Group 1, a basic questionnaire concerning age, sex, and past and family histories; Group 2, 15 warning signs selected on the basis of retrospective study; and Groups 3-7, detailed questions concerning each sign. Scoring weights assigned to each condition based on the results of the retrospective study, and threshold values were determined by several neurosurgeons. The certainty factors for intermediate hypotheses were calculated from these weights and threshold values and summed up, from which the conclusion was obtained. Twelve new cases of unruptured cerebral aneurysm were diagnosed using this screening system. This system may improve the ability to diagnose cerebral aneurysms before rupture. (author)

  4. Dynamic screening and electron dynamics in low-dimensional metal systems

    International Nuclear Information System (INIS)

    Silkin, V.M.; Quijada, M.; Vergniory, M.G.; Alducin, M.; Borisov, A.G.; Diez Muino, R.; Juaristi, J.I.; Sanchez-Portal, D.; Chulkov, E.V.; Echenique, P.M.

    2007-01-01

    Recent advances in the theoretical description of dynamic screening and electron dynamics in metallic media are reviewed. The time-dependent building-up of screening in different situations is addressed. Perturbative and non-perturbative theories are used to study electron dynamics in low-dimensional systems, such as metal clusters, image states, surface states and quantum wells. Modification of the electronic lifetimes due to confinement effects is analyzed as well

  5. The Compact Muon Solenoid Detector Control System

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The Compact Muon Solenoid (CMS) is a CERN multi-purpose experiment that exploits the physics of the Large Hadron Collider (LHC). The Detector Control System (DCS) ensures a safe, correct and efficient experiment operation, contributing to the recording of high quality physics data. The DCS is programmed to automatically react to the LHC changes. CMS sub-detector’s bias voltages are set depending on the machine mode and particle beam conditions. A protection mechanism ensures that the sub-detectors are locked in a safe mode whenever a potentially dangerous situation exists. The system is supervised from the experiment control room by a single operator. A small set of screens summarizes the status of the detector from the approximately 6M monitored parameters. Using the experience of nearly two years of operation with beam the DCS automation software has been enhanced to increase the system efficiency. The automation allows now for configuration commands that can be used to automatically pre-configure hardwar...

  6. Brain MRI screening showing evidences of early central nervous system involvement in patients with systemic sclerosis.

    Science.gov (United States)

    Mohammed, Reem Hamdy A; Sabry, Yousriah Y; Nasef, Amr A

    2011-05-01

    Systemic sclerosis is a multisystem autoimmune collagen disease where structural and functional abnormalities of small blood vessels prevail. Transient ischemic attacks, ischemic stroke, and hemorrhage have been reported as primary consequence of vascular central nervous system affection in systemic sclerosis. Magnetic resonance imaging is considered to be the most sensitive diagnostic technique for detecting symptomatic and asymptomatic lesions in the brain in cases of multifocal diseases. The objective of this study is to detect subclinical as well as clinically manifest cerebral vasculopathy in patients with systemic sclerosis using magnetic resonance imaging. As much as 30 female patients with systemic sclerosis aged 27-61 years old, with disease duration of 1-9 years and with no history of other systemic disease or cerebrovascular accidents, were enrolled. Age-matched female control group of 30 clinically normal subjects, underwent brain magnetic resonance examination. Central nervous system (CNS) involvement in the form of white matter hyperintense foci of variable sizes were found in significantly abundant forms in systemic sclerosis patients on magnetic resonance evaluation than in age-related control group, signifying a form of CNS vasculopathy. Such foci showed significant correlation to clinical features of organic CNS lesion including headaches, fainting attacks and organic depression as well as to the severity of peripheral vascular disease with insignificant correlation with disease duration. In conclusion, subclinical as well as clinically manifest CNS ischemic vasculopathy is not uncommon in systemic sclerosis patients and magnetic resonance imaging is considered a sensitive noninvasive screening tool for early detection of CNS involvement in patients with systemic sclerosis.

  7. Screen-Time Weight-loss Intervention Targeting Children at Home (SWITCH): a randomized controlled trial.

    Science.gov (United States)

    Maddison, Ralph; Marsh, Samantha; Foley, Louise; Epstein, Leonard H; Olds, Timothy; Dewes, Ofa; Heke, Ihirangi; Carter, Karen; Jiang, Yannan; Mhurchu, Cliona Ni

    2014-09-10

    Screen-based activities, such as watching television (TV), playing video games, and using computers, are common sedentary behaviors among young people and have been linked with increased energy intake and overweight. Previous home-based sedentary behaviour interventions have been limited by focusing primarily on the child, small sample sizes, and short follow-up periods. The SWITCH (Screen-Time Weight-loss Intervention Targeting Children at Home) study aimed to determine the effect of a home-based, family-delivered intervention to reduce screen-based sedentary behaviour on body composition, sedentary behaviour, physical activity, and diet over 24 weeks in overweight and obese children. A two-arm, parallel, randomized controlled trial was conducted. Children and their primary caregiver living in Auckland, New Zealand were recruited via schools, community centres, and word of mouth. The intervention, delivered over 20 weeks, consisted of a face-to-face meeting with the parent/caregiver and the child to deliver intervention content, which focused on training and educating them to use a wide range of strategies designed to reduce their child's screen time. Families were given Time Machine TV monitoring devices to assist with allocating screen time, activity packages to promote alternative activities, online support via a website, and monthly newsletters. Control participants were given the intervention material on completion of follow-up. The primary outcome was change in children's BMI z-score from baseline to 24 weeks. Children (n = 251) aged 9-12 years and their primary caregiver were randomized to receive the SWITCH intervention (n = 127) or no intervention (controls; n = 124). There was no significant difference in change of zBMI between the intervention and control groups, although a favorable trend was observed (-0.016; 95% CI: -0.084, 0.051; p = 0.64). There were also no significant differences on secondary outcomes, except for a trend towards

  8. Development, structure and qualification of a new digital instrumentation and control system

    International Nuclear Information System (INIS)

    Hofmann, H.; Sauer, H.J.

    1991-01-01

    Introduction of digital instrumentation and control in nuclear power plants is characterized by the need to meet numerous requirements concerning reliability, ergonomic design of the main control room and comprehensive qualification. The system described here is distinguished by a hierarchical and modular structure, being redundant throughout. Ergonomic considerations dominate the layout of the screen-based main control room. Powerful computer-aided engineering tools are employed for planning of the entire system and for generation of the user software. Qualification is performed in step with the development of the system, based on the applicable national and international rules and regulations and in close cooperation with an independent expert. (orig.) [de

  9. Screening and brief interventions for hazardous and harmful alcohol use in probation services: a cluster randomised controlled trial protocol

    Directory of Open Access Journals (Sweden)

    Myles Judy

    2009-11-01

    Full Text Available Abstract Background A large number of randomised controlled trials in health settings have consistently reported positive effects of brief intervention in terms of reductions in alcohol use. However, although alcohol misuse is common amongst offenders, there is limited evidence of alcohol brief interventions in the criminal justice field. This factorial pragmatic cluster randomised controlled trial with Offender Managers (OMs as the unit of randomisation will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in probation and different intensities of brief intervention to reduce excessive drinking in probation clients. Methods and design Ninety-six OMs from 9 probation areas across 3 English regions (the North East Region (n = 4 and London and the South East Regions (n = 5 will be recruited. OMs will be randomly allocated to one of three intervention conditions: a client information leaflet control condition (n = 32 OMs; 5-minute simple structured advice (n = 32 OMs and 20-minute brief lifestyle counselling delivered by an Alcohol Health Worker (n = 32 OMs. Randomisation will be stratified by probation area. To test the relative effectiveness of different screening methods all OMs will be randomised to either the Modified Single Item Screening Questionnaire (M-SASQ or the Fast Alcohol Screening Test (FAST. There will be a minimum of 480 clients recruited into the trial. There will be an intention to treat analysis of study outcomes at 6 and 12 months post intervention. Analysis will include client measures (screening result, weekly alcohol consumption, alcohol-related problems, re-offending, public service use and quality of life and implementation measures from OMs (the extent of screening and brief intervention beyond the minimum recruitment threshold will provide data on acceptability and feasibility of different models of brief intervention. We will also examine the

  10. Screening and brief interventions for hazardous and harmful alcohol use in probation services: a cluster randomised controlled trial protocol.

    Science.gov (United States)

    Newbury-Birch, Dorothy; Bland, Martin; Cassidy, Paul; Coulton, Simon; Deluca, Paolo; Drummond, Colin; Gilvarry, Eilish; Godfrey, Christine; Heather, Nick; Kaner, Eileen; Myles, Judy; Oyefeso, Adenekan; Parrott, Steve; Perryman, Katherine; Phillips, Tom; Shenker, Don; Shepherd, Jonathan

    2009-11-18

    A large number of randomised controlled trials in health settings have consistently reported positive effects of brief intervention in terms of reductions in alcohol use. However, although alcohol misuse is common amongst offenders, there is limited evidence of alcohol brief interventions in the criminal justice field. This factorial pragmatic cluster randomised controlled trial with Offender Managers (OMs) as the unit of randomisation will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in probation and different intensities of brief intervention to reduce excessive drinking in probation clients. Ninety-six OMs from 9 probation areas across 3 English regions (the North East Region (n = 4) and London and the South East Regions (n = 5)) will be recruited. OMs will be randomly allocated to one of three intervention conditions: a client information leaflet control condition (n = 32 OMs); 5-minute simple structured advice (n = 32 OMs) and 20-minute brief lifestyle counselling delivered by an Alcohol Health Worker (n = 32 OMs). Randomisation will be stratified by probation area. To test the relative effectiveness of different screening methods all OMs will be randomised to either the Modified Single Item Screening Questionnaire (M-SASQ) or the Fast Alcohol Screening Test (FAST). There will be a minimum of 480 clients recruited into the trial. There will be an intention to treat analysis of study outcomes at 6 and 12 months post intervention. Analysis will include client measures (screening result, weekly alcohol consumption, alcohol-related problems, re-offending, public service use and quality of life) and implementation measures from OMs (the extent of screening and brief intervention beyond the minimum recruitment threshold will provide data on acceptability and feasibility of different models of brief intervention). We will also examine the practitioner and organisational factors

  11. Performance of an automated electronic acute lung injury screening system in intensive care unit patients.

    Science.gov (United States)

    Koenig, Helen C; Finkel, Barbara B; Khalsa, Satjeet S; Lanken, Paul N; Prasad, Meeta; Urbani, Richard; Fuchs, Barry D

    2011-01-01

    Lung protective ventilation reduces mortality in patients with acute lung injury, but underrecognition of acute lung injury has limited its use. We recently validated an automated electronic acute lung injury surveillance system in patients with major trauma in a single intensive care unit. In this study, we assessed the system's performance as a prospective acute lung injury screening tool in a diverse population of intensive care unit patients. Patients were screened prospectively for acute lung injury over 21 wks by the automated system and by an experienced research coordinator who manually screened subjects for enrollment in Acute Respiratory Distress Syndrome Clinical Trials Network (ARDSNet) trials. Performance of the automated system was assessed by comparing its results with the manual screening process. Discordant results were adjudicated blindly by two physician reviewers. In addition, a sensitivity analysis using a range of assumptions was conducted to better estimate the system's performance. The Hospital of the University of Pennsylvania, an academic medical center and ARDSNet center (1994-2006). Intubated patients in medical and surgical intensive care units. None. Of 1270 patients screened, 84 were identified with acute lung injury (incidence of 6.6%). The automated screening system had a sensitivity of 97.6% (95% confidence interval, 96.8-98.4%) and a specificity of 97.6% (95% confidence interval, 96.8-98.4%). The manual screening algorithm had a sensitivity of 57.1% (95% confidence interval, 54.5-59.8%) and a specificity of 99.7% (95% confidence interval, 99.4-100%). Sensitivity analysis demonstrated a range for sensitivity of 75.0-97.6% of the automated system under varying assumptions. Under all assumptions, the automated system demonstrated higher sensitivity than and comparable specificity to the manual screening method. An automated electronic system identified patients with acute lung injury with high sensitivity and specificity in diverse

  12. Risk stratification and rapid geriatric screening in an emergency department - a quasi-randomised controlled trial.

    Science.gov (United States)

    Foo, Chik Loon; Siu, Vivan Wing Yin; Ang, Hou; Phuah, Madeline Wei Ling; Ooi, Chee Kheong

    2014-08-30

    To determine if risk stratification followed by rapid geriatric screening in an emergency department (ED) reduced functional decline, ED reattendance and hospitalisation. This was a quasi-randomised controlled trial. Patients were randomised by the last digit of their national registration identity card (NRIC). Odd number controls received standard ED care; even number patients received geriatric screening, followed by intervention and/or onward referrals. Patients were followed up for 12 months. There were 500 and 280 patients in the control and intervention groups. The intervention group had higher Triage Risk Screening Tool (TRST) scores (34.3% vs 25.4% TRST ≥3, p = 0.01) and lower baseline Instrumental Activity of Daily Living (IADL) scores (22.84 vs 24.18, p fall risk (65.0%), vision (61.4%), and footwear (58.2%). 28.2% were referred to a geriatric clinic and 11.8% were admitted. 425 (85.0%) controls and 234 (83.6%) in the intervention group completed their follow-up. After adjusting for TRST and baseline IADL, the intervention group had significant preservation in function (Basic ADL -0.99 vs -0.24, p geriatric screening at the request of the ED doctor. A major limitation was that a large proportion of patients who were randomized to the intervention group either refused (18.8%) or left the ED before being approached (32.0%). These two groups were not followed up, and hence were excluded in our analysis. Risk stratification and focused geriatric screening in ED resulted in significant preservation of patients' function at 12 months. National Healthcare Group (NHG) Domain Specific Review Board (DSRB) C/09/023. Registered 5th March 2009.

  13. Fully synthetic phage-like system for screening mixtures of small molecules in live cells.

    Science.gov (United States)

    Byk, Gerardo; Partouche, Shirly; Weiss, Aryeh; Margel, Shlomo; Khandadash, Raz

    2010-05-10

    A synthetic "phage-like" system was designed for screening mixtures of small molecules in live cells. The core of the system consists of 2 mum diameter cross-linked monodispersed microspheres bearing a panel of fluorescent tags and peptides or small molecules either directly synthesized or covalently conjugated to the microspheres. The microsphere mixtures were screened for affinity to cell line PC-3 (prostate cancer model) by incubation with live cells, and as was with phage-display peptide methods, unbound microspheres were removed by repeated washings followed by total lysis of cells and analysis of the bound microspheres by flow-cytometry. Similar to phage-display peptide screening, this method can be applied even in the absence of prior information about the cellular targets of the candidate ligands, which makes the system especially interesting for selection of molecules with high affinity for desired cells, tissues, or tumors. The advantage of the proposed system is the possibility of screening synthetic non-natural peptides or small molecules that cannot be expressed and screened using phage display libraries. A library composed of small molecules synthesized by the Ugi reaction was screened, and a small molecule, Rak-2, which strongly binds to PC-3 cells was found. Rak-2 was then individually synthesized and validated in a complementary whole cell-based binding assay, as well as by live cell microscopy. This new system demonstrates that a mixture of molecules bound to subcellular sized microspheres can be screened on plated cells. Together with other methods using subcellular sized particles for cellular multiplexing, this method represents an important milestone toward high throughput screening of mixtures of small molecules in live cells and in vivo with potential applications in the fields of drug delivery and diagnostic imaging.

  14. Intelligent viewing control for robotic and automation systems

    Science.gov (United States)

    Schenker, Paul S.; Peters, Stephen F.; Paljug, Eric D.; Kim, Won S.

    1994-10-01

    We present a new system for supervisory automated control of multiple remote cameras. Our primary purpose in developing this system has been to provide capability for knowledge- based, `hands-off' viewing during execution of teleoperation/telerobotic tasks. The reported technology has broader applicability to remote surveillance, telescience observation, automated manufacturing workcells, etc. We refer to this new capability as `Intelligent Viewing Control (IVC),' distinguishing it from a simple programmed camera motion control. In the IVC system, camera viewing assignment, sequencing, positioning, panning, and parameter adjustment (zoom, focus, aperture, etc.) are invoked and interactively executed by real-time by a knowledge-based controller, drawing on a priori known task models and constraints, including operator preferences. This multi-camera control is integrated with a real-time, high-fidelity 3D graphics simulation, which is correctly calibrated in perspective to the actual cameras and their platform kinematics (translation/pan-tilt). Such merged graphics- with-video design allows the system user to preview and modify the planned (`choreographed') viewing sequences. Further, during actual task execution, the system operator has available both the resulting optimized video sequence, as well as supplementary graphics views from arbitrary perspectives. IVC, including operator-interactive designation of robot task actions, is presented to the user as a well-integrated video-graphic single screen user interface allowing easy access to all relevant telerobot communication/command/control resources. We describe and show pictorial results of a preliminary IVC system implementation for telerobotic servicing of a satellite.

  15. Sampling for quality assurance of grading decisions in diabetic retinopathy screening: designing the system to detect errors.

    Science.gov (United States)

    Slattery, Jim

    2005-01-01

    To evaluate various designs for a quality assurance system to detect and control human errors in a national screening programme for diabetic retinopathy. A computer simulation was performed of some possible ways of sampling the referral decisions made during grading and of different criteria for initiating more intensive QA investigations. The effectiveness of QA systems was assessed by the ability to detect a grader making occasional errors in referral. Substantial QA sample sizes are needed to ensure against inappropriate failure to refer. Detection of a grader who failed to refer one in ten cases can be achieved with a probability of 0.58 using an annual sample size of 300 and 0.77 using a sample size of 500. An unmasked verification of a sample of non-referrals by a specialist is the most effective method of internal QA for the diabetic retinopathy screening programme. Preferential sampling of those with some degree of disease may improve the efficiency of the system.

  16. Sweeten, soother and swaddle for retinopathy of prematurity screening: a randomised placebo controlled trial.

    LENUS (Irish Health Repository)

    O'Sullivan, A

    2012-02-01

    OBJECTIVE: To assess the efficacy of oral sucrose combined with swaddling and non-nutritive suck (NNS) as a method for reducing pain associated with retinopathy of prematurity (ROP) screening. DESIGN: Randomised placebo controlled study. SETTING: Tertiary level neonatal intensive care unit. SAMPLE: 40 infants undergoing primary eye examination for ROP screening. INTERVENTION: The control group were swaddled, and received 0.2 ml of sterile water given by mouth using a syringe and a soother. The intervention group were swaddled, and received 0.2 ml of sucrose 24% given by mouth using a syringe and a soother. RESULTS: 40 infants were included in the study. There was no difference in mean gestational age at birth, mean birth weight or corrected gestational age at first examination between both groups. The sucrose group had a significantly lower median Neonatal Pain, Agitation and Sedation Scale (N-PASS) score during ROP screening, initially following insertion of the speculum (6.5 vs 5, p=0.02) and subsequently during scleral indentation (9.5 vs 7.5, p=0.03). Fewer infants experienced episodes of desaturations or bradycardia in the intervention group (1 vs 4, p=0.18). CONCLUSION: ROP screening is a necessary but recognised painful procedure. Sucrose combined with NNS and swaddling reduced the behavioural and physiological pain responses. However, pain scores remained consistently high and appropriate pain relief for ROP screening remains a challenge.

  17. An Improved On-line Contingency Screening for Power System Transient Stability Assessment

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Glavic, Mevludin

    2017-01-01

    This paper presents a contingency screening method and a framework for its on-line implementation. The proposed method carries out contingency screening and on-line stability assessment with respect to first-swing transient stability. For that purpose, it utilizes the single machine equivalent...... method and aims at improving the prior developed contingency screening approaches. In order to determine vulnerability of the system with respect to a particular contingency, only one time-domain simulation needs to be performed. An early stop criteria is proposed so that in a majority of the cases...... the simulation can be terminated after a few hundred milliseconds of simulated system response. The method's outcome is an assessment of the system's stability and a classification of each considered contingency. The contingencies are categorized by exploiting parameters of an equivalent one machine infinite bus...

  18. The ADDITION-Cambridge trial protocol: a cluster – randomised controlled trial of screening for type 2 diabetes and intensive treatment for screen-detected patients

    Directory of Open Access Journals (Sweden)

    Kinmonth Ann

    2009-05-01

    Full Text Available Abstract Background The increasing prevalence of type 2 diabetes poses a major public health challenge. Population-based screening and early treatment for type 2 diabetes could reduce this growing burden. However, the benefits of such a strategy remain uncertain. Methods and design The ADDITION-Cambridge study aims to evaluate the effectiveness and cost-effectiveness of (i a stepwise screening strategy for type 2 diabetes; and (ii intensive multifactorial treatment for people with screen-detected diabetes in primary care. 63 practices in the East Anglia region participated. Three undertook the pilot study, 33 were allocated to three groups: no screening (control, screening followed by intensive treatment (IT and screening plus routine care (RC in an unbalanced (1:3:3 randomisation. The remaining 27 practices were randomly allocated to IT and RC. A risk score incorporating routine practice data was used to identify people aged 40–69 years at high-risk of undiagnosed diabetes. In the screening practices, high-risk individuals were invited to take part in a stepwise screening programme. In the IT group, diabetes treatment is optimised through guidelines, target-led multifactorial treatment, audit, feedback, and academic detailing for practice teams, alongside provision of educational materials for newly diagnosed participants. Primary endpoints are modelled cardiovascular risk at one year, and cardiovascular mortality and morbidity at five years after diagnosis of diabetes. Secondary endpoints include all-cause mortality, development of renal and visual impairment, peripheral neuropathy, health service costs, self-reported quality of life, functional status and health utility. Impact of the screening programme at the population level is also assessed through measures of mortality, cardiovascular morbidity, health status and health service use among high-risk individuals. Discussion ADDITION-Cambridge is conducted in a defined high-risk group

  19. STATE ACID RAIN RESEARCH AND SCREENING SYSTEM - VERSION 1.0 USER'S MANUAL

    Science.gov (United States)

    The report is a user's manual that describes Version 1.0 of EPA's STate Acid Rain Research and Screening System (STARRSS), developed to assist utility regulatory commissions in reviewing utility acid rain compliance plans. It is a screening tool that is based on scenario analysis...

  20. Breast Cancer Screening, Mammography, and Other Modalities.

    Science.gov (United States)

    Fiorica, James V

    2016-12-01

    This article is an overview of the modalities available for breast cancer screening. The modalities discussed include digital mammography, digital breast tomosynthesis, breast ultrasonography, magnetic resonance imaging, and clinical breast examination. There is a review of pertinent randomized controlled trials, studies and meta-analyses which contributed to the evolution of screening guidelines. Ultimately, 5 major medical organizations formulated the current screening guidelines in the United States. The lack of consensus in these guidelines represents an ongoing controversy about the optimal timing and method for breast cancer screening in women. For mammography screening, the Breast Imaging Reporting and Data System lexicon is explained which corresponds with recommended clinical management. The presentation and discussion of the data in this article are designed to help the clinician individualize breast cancer screening for each patient.

  1. Development of a Novel Antimicrobial Screening System Targeting the Pyoverdine-Mediated Iron Acquisition System and Xenobiotic Efflux Pumps

    Directory of Open Access Journals (Sweden)

    Kazuki Sato

    2015-04-01

    Full Text Available The iron acquisition systems in Pseudomonas aeruginosa are inducible in response to low-iron conditions and important for growth of this organism under iron limitation. OprM is the essential outer membrane subunit of the MexAB-OprM xenobiotic efflux pump. We designed and constructed a new model antimicrobial screening system targeting both the iron-uptake system and xenobiotic efflux pumps. The oprM gene was placed immediately downstream of the ferri-pyoverdine receptor gene, fpvA, in the host lacking chromosomal oprM and the expression of oprM was monitored by an antibiotic susceptibility test under iron depleted and replete conditions. The recombinant cells showed wild-type susceptibility to pump substrate antibiotics, e.g., aztreonam, under iron limitation and became supersusceptible to them under iron repletion, suggesting that expression of oprM is under control of the iron acquisition system. Upon screening of a chemical library comprising 2952 compounds using this strain, a compound—ethyl 2-(1-acetylpiperidine-4-carboxamido-4,5,6,7-tetrahydrobenzo[b]thiophene-3-carboxylate—was found to enhance the efficacy of aztreonam under iron limitation, suggesting that the compound inhibits either the iron acquisition system or the MexAB-OprM efflux pump. This compound was subsequently found to inhibit the growth of wild-type cells in the presence of sublethal amounts of aztreonam, regardless of the presence or absence of dipyridyl, an iron-chelator. The compound was eventually identified to block the function of the MexAB-OprM efflux pump, showing the validity of this new method.

  2. Development of a novel antimicrobial screening system targeting the pyoverdine-mediated iron acquisition system and xenobiotic efflux pumps.

    Science.gov (United States)

    Sato, Kazuki; Ushioda, Kenichi; Akiba, Keiji; Matsumoto, Yoshimi; Maseda, Hideaki; Ando, Tasuke; Isogai, Emiko; Nakae, Taiji; Yoneyama, Hiroshi

    2015-04-29

    The iron acquisition systems in Pseudomonas aeruginosa are inducible in response to low-iron conditions and important for growth of this organism under iron limitation. OprM is the essential outer membrane subunit of the MexAB-OprM xenobiotic efflux pump. We designed and constructed a new model antimicrobial screening system targeting both the iron-uptake system and xenobiotic efflux pumps. The oprM gene was placed immediately downstream of the ferri-pyoverdine receptor gene, fpvA, in the host lacking chromosomal oprM and the expression of oprM was monitored by an antibiotic susceptibility test under iron depleted and replete conditions. The recombinant cells showed wild-type susceptibility to pump substrate antibiotics, e.g., aztreonam, under iron limitation and became supersusceptible to them under iron repletion, suggesting that expression of oprM is under control of the iron acquisition system. Upon screening of a chemical library comprising 2952 compounds using this strain, a compound-ethyl 2-(1-acetylpiperidine-4-carboxamido)-4,5,6,7-tetrahydrobenzo[b]thiophene-3-carboxylate-was found to enhance the efficacy of aztreonam under iron limitation, suggesting that the compound inhibits either the iron acquisition system or the MexAB-OprM efflux pump. This compound was subsequently found to inhibit the growth of wild-type cells in the presence of sublethal amounts of aztreonam, regardless of the presence or absence of dipyridyl, an iron-chelator. The compound was eventually identified to block the function of the MexAB-OprM efflux pump, showing the validity of this new method.

  3. Combinatorial Screening for Transgenic Yeasts with High Cellulase Activities in Combination with a Tunable Expression System.

    Directory of Open Access Journals (Sweden)

    Yoichiro Ito

    Full Text Available Combinatorial screening used together with a broad library of gene expression cassettes is expected to produce a powerful tool for the optimization of the simultaneous expression of multiple enzymes. Recently, we proposed a highly tunable protein expression system that utilized multiple genome-integrated target genes to fine-tune enzyme expression in yeast cells. This tunable system included a library of expression cassettes each composed of three gene-expression control elements that in different combinations produced a wide range of protein expression levels. In this study, four gene expression cassettes with graded protein expression levels were applied to the expression of three cellulases: cellobiohydrolase 1, cellobiohydrolase 2, and endoglucanase 2. After combinatorial screening for transgenic yeasts simultaneously secreting these three cellulases, we obtained strains with higher cellulase expressions than a strain harboring three cellulase-expression constructs within one high-performance gene expression cassette. These results show that our method will be of broad use throughout the field of metabolic engineering.

  4. Combinatorial Screening for Transgenic Yeasts with High Cellulase Activities in Combination with a Tunable Expression System

    Science.gov (United States)

    Ito, Yoichiro; Yamanishi, Mamoru; Ikeuchi, Akinori; Imamura, Chie; Matsuyama, Takashi

    2015-01-01

    Combinatorial screening used together with a broad library of gene expression cassettes is expected to produce a powerful tool for the optimization of the simultaneous expression of multiple enzymes. Recently, we proposed a highly tunable protein expression system that utilized multiple genome-integrated target genes to fine-tune enzyme expression in yeast cells. This tunable system included a library of expression cassettes each composed of three gene-expression control elements that in different combinations produced a wide range of protein expression levels. In this study, four gene expression cassettes with graded protein expression levels were applied to the expression of three cellulases: cellobiohydrolase 1, cellobiohydrolase 2, and endoglucanase 2. After combinatorial screening for transgenic yeasts simultaneously secreting these three cellulases, we obtained strains with higher cellulase expressions than a strain harboring three cellulase-expression constructs within one high-performance gene expression cassette. These results show that our method will be of broad use throughout the field of metabolic engineering. PMID:26692026

  5. Remote nuclear screening system for hostile environments

    International Nuclear Information System (INIS)

    Addleman, R.S.; Keele, B.D.

    1996-01-01

    A remote measurement system has been constructed for in situ gamma and beta isotopic characterization of highly radioactive nuclear material in hostile environments. A small collimated, planar CdZnTe detector is used for gamma-ray spectroscopy. Spectral resolution of 2% full width at half maximum at 662 kiloelectronvolts has been obtained remotely using rise time compensation and limited pulse shape discrimination, Isotopc measurement of high-energy beta emitters was accomplished with a ruggedized, deeply depleted, surface barrier silicon dictator. The primary function of the remote nuclear screening system is to provide fast qualitative and quantitative isotopic assessment of high-level radioactive material

  6. Rectal swab screening assays of public health importance in molecular diagnostics: Sample adequacy control.

    Science.gov (United States)

    Glisovic, Sanja; Eintracht, Shaun; Longtin, Yves; Oughton, Matthew; Brukner, Ivan

    Rectal swabs are routinely used by public health authorities to screen for multi-drug resistant enteric bacteria including vancomycin-resistant enterococci (VRE) and carbapenem-resistant enterobacteriaceae (CRE). Screening sensitivity can be influenced by the quality of the swabbing, whether performed by the patient (self-swabbing) or a healthcare practitioner. One common exclusion criterion for rectal swabs is absence of "visible soiling" from fecal matter. In our institution, this criterion excludes almost 10% of rectal swabs received in the microbiology laboratory. Furthermore, over 30% of patients in whom rectal swabs are cancelled will not be re-screened within the next 48h, resulting in delays in removing infection prevention measures. We describe two quantitative polymerase chain reaction (qPCR)-based assays, human RNAse P and eubacterial 16S rDNA, which might serve as suitable controls for sampling adequacy. However, lower amounts of amplifiable human DNA make the 16s rDNA assay a better candidate for sample adequacy control. Copyright © 2017. Published by Elsevier Ltd.

  7. How information about overdetection changes breast cancer screening decisions: a mediation analysis within a randomised controlled trial.

    Science.gov (United States)

    Hersch, Jolyn; McGeechan, Kevin; Barratt, Alexandra; Jansen, Jesse; Irwig, Les; Jacklyn, Gemma; Houssami, Nehmat; Dhillon, Haryana; McCaffery, Kirsten

    2017-10-06

    In a randomised controlled trial, we found that informing women about overdetection changed their breast screening decisions. We now present a mediation analysis exploring the psychological pathways through which study participants who received the intervention processed information about overdetection and how this influenced their decision-making. We examined a series of potential mediators in the causal chain between exposure to overdetection information and women's subsequently reported breast screening intentions. Serial multiple mediation analysis within a randomised controlled trial. New South Wales, Australia. 811 women aged 48-50 years with no personal history of breast cancer. Two versions of a decision aid giving women information about breast cancer deaths averted and false positives from mammography screening, either with (intervention) or without (control) information on overdetection. Intentions to undergo breast cancer screening in the next 2-3 years. Knowledge about overdetection, worry about breast cancer, attitudes towards breast screening and anticipated regret. The effect of information about overdetection on women's breast screening intentions was mediated through multiple cognitive and affective processes. In particular, the information led to substantial improvements in women's understanding of overdetection, and it influenced-both directly and indirectly via its effect on knowledge-their attitudes towards having screening. Mediation analysis showed that the mechanisms involving knowledge and attitudes were particularly important in determining women's intentions about screening participation. Even in this emotive context, new information influenced women's decision-making by changing their understanding of possible consequences of screening and their attitudes towards undergoing it. These findings emphasise the need to provide good-quality information on screening outcomes and to communicate this information effectively, so that women can

  8. Quality assessment in prospective nuchal translucency screening for Down syndrome

    DEFF Research Database (Denmark)

    Wøjdemann, K R; Christiansen, M; Sundberg, K

    2001-01-01

    OBJECTIVES: To develop and apply a quality control system in a Down syndrome screening study using nuchal translucency as an interventional marker. METHODS: In a prospective Down syndrome screening study fetal nuchal translucency thickness was measured in 9236 of the 10 045 examined pregnancies...

  9. A decision support system for the control of Campylobacter in chickens at farm level using data from Denmark

    DEFF Research Database (Denmark)

    Garcia, A. B.; Madsen, A. L.; Vigre, Håkan

    2016-01-01

    strategy seems to be the use of fly screens. The use of cost-effective vaccines against Campylobacter is also desirable. In order to control Campylobacter, poultry producers need to make crucial decisions under conditions of uncertainty. With the aim of assisting poultry producers in decision making...... regarding Campylobacter control strategies, the objective of the present study was to produce a decision support system that integrated knowledge and used a Bayesian approach to handle uncertainty. This decision support system integrated epidemiological data, microbiological considerations, financial...... information and potential control strategies (the use of fly screens and hypothetical vaccines). In conclusion, results from model and sensitivity analyses indicated that the financial variables (cost–benefit functions) and the effectiveness of the different control strategies drove the results....

  10. A new screening method to identify inhibitors of the Lol (localization of lipoproteins) system, a novel antibacterial target.

    Science.gov (United States)

    Ito, Hideaki; Ura, Atsushi; Oyamada, Yoshihiro; Yoshida, Hiroaki; Yamagishi, Jun-Ichi; Narita, Shin-Ichiro; Matsuyama, Shin-Ichi; Tokuda, Hajime

    2007-01-01

    As the Lol system, which is involved in localization of lipoproteins, is essential for Escherichia coli growth and widely conserved among gram-negative bacteria, it is considered to be a promising target for the development of anti-gram-negative bacterial agents. However, no high-throughput screening method has so far been developed to screen for Lol system inhibitors. By combining three assay systems (anucleate cell blue assay, Lpp assay, and LolA-dependent release inhibition assay) and a drug susceptibility test, we have successfully developed a new screening method for identification of compounds that inhibit the Lol system. Using this new screening method, we screened 23,600 in-house chemical compounds and found 2 Lol system inhibitors. We therefore conclude that our new screening method can efficiently identify new antibacterial agents that target the Lol system.

  11. State of affairs of tuberculosis in prison facilities: a systematic review of screening practices and recommendations for best TB control.

    Directory of Open Access Journals (Sweden)

    Natalie V S Vinkeles Melchers

    Full Text Available BACKGROUND: Prisoners are at high risk of developing tuberculosis (TB, causing morbidity and mortality. Prison facilities encounter many challenges in TB screening procedures and TB control. This review explores screening practices for detection of TB and describes limitations of TB control in prison facilities worldwide. METHODS: A systematic search of online databases (e.g., PubMed and Embase and conference abstracts was carried out. Research papers describing screening and diagnostic practices among prisoners were included. A total of 52 articles met the inclusion criteria. A meta-analysis of TB prevalence in prison facilities by screening and diagnostic tools was performed. RESULTS: The most common screening tool was symptom questionnaires (63·5%, mostly reporting presence of cough. Microscopy of sputum with Ziehl-Neelsen staining and solid culture were the most frequently combined diagnostic methods (21·2%. Chest X-ray and tuberculin skin tests were used by 73·1% and 50%, respectively, as either a screening and/or diagnostic tool. Median TB prevalence among prisoners of all included studies was 1,913 cases of TB per 100,000 prisoners (interquartile range [IQR]: 332-3,517. The overall annual median TB incidence was 7·0 cases per 1000 person-years (IQR: 2·7-30·0. Major limitations for successful TB control were inaccuracy of diagnostic algorithms and the lack of adequate laboratory facilities reported by 61·5% of studies. The most frequent recommendation for improving TB control and case detection was to increase screening frequency (73·1%. DISCUSSION: TB screening algorithms differ by income area and should be adapted to local contexts. In order to control TB, prison facilities must improve laboratory capacity and frequent use of effective screening and diagnostic tools. Sustainable political will and funding are critical to achieve this.

  12. Study on fault diagnosis and load feedback control system of combine harvester

    Science.gov (United States)

    Li, Ying; Wang, Kun

    2017-01-01

    In order to timely gain working status parameters of operating parts in combine harvester and improve its operating efficiency, fault diagnosis and load feedback control system is designed. In the system, rotation speed sensors were used to gather these signals of forward speed and rotation speeds of intermediate shaft, conveying trough, tangential and longitudinal flow threshing rotors, grain conveying auger. Using C8051 single chip microcomputer (SCM) as processor for main control unit, faults diagnosis and forward speed control were carried through by rotation speed ratio analysis of each channel rotation speed and intermediate shaft rotation speed by use of multi-sensor fused fuzzy control algorithm, and these processing results would be sent to touch screen and display work status of combine harvester. Field trials manifest that fault monitoring and load feedback control system has good man-machine interaction and the fault diagnosis method based on rotation speed ratios has low false alarm rate, and the system can realize automation control of forward speed for combine harvester.

  13. Research on Multioperator silk screen printer Based on Communication Protocol Macro

    Directory of Open Access Journals (Sweden)

    Zhiming Zhang

    2018-01-01

    Full Text Available Multioperator silk screen printer is automatic silk screen printing equipment. There are many advantages, such as energy saving, reduce the labor intensity and so on. The control system consists of an intermittent movement main motor and eight color working station printing cycle motion motors. The system controls nine frequency converters through protocol macro communication by using PLC. This paper studies the principle and process characteristics of multioperator silk screen printer. Besides, this paper adopts protocol macro sequence generation method for communication between PLC and frequency converter. This method can control the programming of parameters, such as frequency, operation and monitoring. It also can realize the printing of eight color working stations and monitor the printing status in real time. The practical application proves that the method meets the technical requirements and the reliability is good.

  14. Design of the control system for full-color LED display based on MSP430 MCU

    Science.gov (United States)

    Li, Xue; Xu, Hui-juan; Qin, Ling-ling; Zheng, Long-jiang

    2013-08-01

    The LED display incorporate the micro electronic technique, computer technology and information processing as a whole, it becomes the most preponderant of a new generation of display media with the advantages of bright in color, high dynamic range, high brightness and long operating life, etc. The LED display has been widely used in the bank, securities trading, highway signs, airport and advertising, etc. According to the display color, the LED display screen is divided into monochrome screen, double color display and full color display. With the diversification of the LED display's color and the ceaseless rise of the display demands, the LED display's drive circuit and control technology also get the corresponding progress and development. The earliest monochrome screen just displaying Chinese characters, simple character or digital, so the requirements of the controller are relatively low. With the widely used of the double color LED display, the performance of its controller will also increase. In recent years, the full color LED display with three primary colors of red, green, blue and grayscale display effect has been highly attention with its rich and colorful display effect. Every true color pixel includes three son pixels of red, green, blue, using the space colour mixture to realize the multicolor. The dynamic scanning control system of LED full-color display is designed based on MSP430 microcontroller technology of the low power consumption. The gray control technology of this system used the new method of pulse width modulation (PWM) and 19 games show principle are combining. This method in meet 256 level grayscale display conditions, improves the efficiency of the LED light device, and enhances the administrative levels feels of the image. Drive circuit used 1/8 scanning constant current drive mode, and make full use of the single chip microcomputer I/O mouth resources to complete the control. The system supports text, pictures display of 256 grayscale

  15. Screening uptake rates and the clinical and cost effectiveness of screening for gestational diabetes mellitus in primary versus secondary care: study protocol for a randomised controlled trial.

    LENUS (Irish Health Repository)

    O Dea, Angela

    2014-01-17

    The risks associated with gestational diabetes mellitus (GDM) are well recognized, and there is increasing evidence to support treatment of the condition. However, clear guidance on the ideal approach to screening for GDM is lacking. Professional groups continue to debate whether selective screening (based on risk factors) or universal screening is the most appropriate approach. Additionally, there is ongoing debate about what levels of glucose abnormalities during pregnancy respond best to treatment and which maternal and neonatal outcomes benefit most from treatment. Furthermore, the implications of possible screening options on health care costs are not well established. In response to this uncertainty there have been repeated calls for well-designed, randomised trials to determine the efficacy of screening, diagnosis, and management plans for GDM. We describe a randomised controlled trial to investigate screening uptake rates and the clinical and cost effectiveness of screening in primary versus secondary care settings. The objective of this study is to assess screening uptake rates, and the clinical and cost effectiveness of screening for GDM in primary versus secondary care.

  16. Clinical comparison of conventional and rare earth screen-film systems for cephalometric radiographs

    International Nuclear Information System (INIS)

    Kaugars, G.E.; Fatouros, P.

    1982-01-01

    This study compared cephalometric and P-A skull films taken with conventional (CaWO4) screens and rare earth screens. Patient exposure was reduced by 17 to 55 percent on two different x-ray machines by the use of rare earth screens. Results from 130 clinical evaluations showed that the diagnostic quality of radiographs taken with either system was roughly comparable. This presents a persuasive argument for the use of rare earth screens since the diagnostic quality of the films can be maintained while significantly reducing the patient's exposure to radiation

  17. To twist or poke? A method for identifying usability issues with the rotary controller and touch screen for control of in-vehicle information systems.

    Science.gov (United States)

    Harvey, Catherine; Stanton, Neville A; Pickering, Carl A; McDonald, Mike; Zheng, Pengjun

    2011-07-01

    In-vehicle information systems (IVIS) can be controlled by the user via direct or indirect input devices. In order to develop the next generation of usable IVIS, designers need to be able to evaluate and understand the usability issues associated with these two input types. The aim of this study was to investigate the effectiveness of a set of empirical usability evaluation methods for identifying important usability issues and distinguishing between the IVIS input devices. A number of usability issues were identified and their causal factors have been explored. These were related to the input type, the structure of the menu/tasks and hardware issues. In particular, the translation between inputs and on-screen actions and a lack of visual feedback for menu navigation resulted in lower levels of usability for the indirect device. This information will be useful in informing the design of new IVIS, with improved usability. STATEMENT OF RELEVANCE: This paper examines the use of empirical methods for distinguishing between direct and indirect IVIS input devices and identifying usability issues. Results have shown that the characteristics of indirect input devices produce more serious usability issues, compared with direct devices and can have a negative effect on the driver-vehicle interaction.

  18. Design approach of soft control system for implementation of advanced MMI in KNGR

    International Nuclear Information System (INIS)

    Kim, J. K.; Choi, M. J.; Choe, I. N.

    1999-01-01

    To overcome the inherent inflexibility of spatially dedicated man-machine interface (MMI) in conventional control room, computer based MMI technologies, along with compact workstation concept, are adopted in KNGR control room target design. In order to achieve the compact workstation design, a large number of spatially dedicated control switches and manual/auto stations in a traditional control room have to be replaced by a few common multi-function devices. These control devices, so called Soft Control System, consist of a personal computer based Flat Panel Display (FPD) device with touch sensitive screen which provides control MMI for the component selected among a number of plant components. Soft Control System is MMI device to allow control of continuous and discrete control device from single panel device. Soft Control System allows a standard interface device to assume the role of numerous control switch and analog control devices via software configuration. This has the advantage of following operator access to all plant control from a single control compact workstation. (author)

  19. Screening for type 2 diabetes and population mortality over 10 years (ADDITION-Cambridge): a cluster-randomised controlled trial.

    Science.gov (United States)

    Simmons, Rebecca K; Echouffo-Tcheugui, Justin B; Sharp, Stephen J; Sargeant, Lincoln A; Williams, Kate M; Prevost, A Toby; Kinmonth, Ann Louise; Wareham, Nicholas J; Griffin, Simon J

    2012-11-17

    The increasing prevalence of type 2 diabetes poses a major public health challenge. Population-based screening and early treatment for type 2 diabetes could reduce this growing burden. However, uncertainty persists around the benefits of screening for type 2 diabetes. We assessed the effect of a population-based stepwise screening programme on mortality. In a pragmatic parallel group, cluster-randomised trial, 33 general practices in eastern England were randomly assigned by the method of minimisation in an unbalanced design to: screening followed by intensive multifactorial treatment for people diagnosed with diabetes (n=15); screening plus routine care of diabetes according to national guidelines (n=13); and a no-screening control group (n=5). The study population consisted of 20,184 individuals aged 40-69 years (mean 58 years), at high risk of prevalent undiagnosed diabetes, on the basis of a previously validated risk score. In screening practices, individuals were invited to a stepwise programme including random capillary blood glucose and glycated haemoglobin (HbA(1c)) tests, a fasting capillary blood glucose test, and a confirmatory oral glucose tolerance test. The primary outcome was all-cause mortality. All participants were flagged for mortality surveillance by the England and Wales Office of National Statistics. Analysis was by intention-to-screen and compared all-cause mortality rates between screening and control groups. This study is registered, number ISRCTN86769081. Of 16,047 high-risk individuals in screening practices, 15,089 (94%) were invited for screening during 2001-06, 11,737 (73%) attended, and 466 (3%) were diagnosed with diabetes. 4137 control individuals were followed up. During 184,057 person-years of follow up (median duration 9·6 years [IQR 8·9-9·9]), there were 1532 deaths in the screening practices and 377 in control practices (mortality hazard ratio [HR] 1·06, 95% CI 0·90-1·25). We noted no significant reduction in

  20. A Small-Molecule Screen for Enhanced Homing of Systemically Infused Cells

    Directory of Open Access Journals (Sweden)

    Oren Levy

    2015-03-01

    Full Text Available Poor homing of systemically infused cells to disease sites may limit the success of exogenous cell-based therapy. In this study, we screened 9,000 signal-transduction modulators to identify hits that increase mesenchymal stromal cell (MSC surface expression of homing ligands that bind to intercellular adhesion molecule 1 (ICAM-1, such as CD11a. Pretreatment of MSCs with Ro-31-8425, an identified hit from this screen, increased MSC firm adhesion to an ICAM-1-coated substrate in vitro and enabled targeted delivery of systemically administered MSCs to inflamed sites in vivo in a CD11a- (and other ICAM-1-binding domains-dependent manner. This resulted in a heightened anti-inflammatory response. This represents a new strategy for engineering cell homing to enhance therapeutic efficacy and validates CD11a and ICAM-1 as potential targets. Altogether, this multi-step screening process may significantly improve clinical outcomes of cell-based therapies.

  1. Large screen mimic display design research for advanced main control room in nuclear power plant

    International Nuclear Information System (INIS)

    Zheng Mingguang; Yang Yanhua; Xu Jijun; Zhang Qinshun; Ning Zhonghe

    2002-01-01

    Firstly the evolution of mimic diagrams or displays used in the main control room of nuclear power plant was introduced. The active functions of mimic diagrams were analyzed on the release of operator psychological burden and pressure, the assistance of operator for the information searching, status understanding, manual actuation, correct decision making as well as the safe and reliable operation of the nuclear power plant. The importance and necessity to use the (large screen) mimic diagrams in advanced main control room of nuclear power plant, the design principle, design details and verification measures of large screen mimic display are also described

  2. [Analysis on the role of Sirius combined topography and tomography system in screening for suspect keratoconus].

    Science.gov (United States)

    Zhang, Y; Chen, Y G; Yang, H Y; Xia, Y J; Zhao, R

    2018-01-11

    Objective: To evaluate the role of Sirius combined topography and tomography system in screening for suspect keratoconus among the corneal refractive surgery candidates. Methods: Retrospective case series study. Eight hundred and sixteen consecutive ametropic patients (1 632 eyes) who underwent routine examinations before corneal refractive surgery at Peking University Third Hospital from January 2016 to September 2016 were reviewed. All the cases were analyzed with Sirius combined topography and tomography system. Fifty-nine eyes of 37 patients, aged (28.9±7.4) years, classified as suspect keratoconus by the system were enrolled in the suspect group, including 25 females (40 eyes) and 12 males (19 eyes). A random eye of the first 59 patients, aged (27.1±6.4)years, whose both eyes were classified as normal by Sirius system were enrolled in the control group, including 38 females and 21 males. The corneal anterior surface, posterior surface and minimum thickness data of the suspect group were analyzed and then compared with the control group. The classified results were further verified by Pentacam system. Independent-samples t test and Mann-Whitney U test were applied to analyze the normal distribution and non-normal distribution data respectively. Results: The medians of anterior surface and posterior surface symmetry index and Baiocchi Calossi Versaci index of anterior surface and posterior surface of the suspect group were 0.84, 0.22, 0.58 and 0.51 D, and that of the control group were 0.05, 0.04, 0.09 and 0.06 D, and the differences were of statistical significance ( Z=- 18.764, -8.351, -12.248, -10.709, Ptopography and tomography and its integral automatic classification system is capable to screen out the suspect keratoconus simply and effectively. These indices maybe arranged in descending order in terms of the sensitivity as corneal posterior surface, followed by corneal anterior surface and then corneal thinnest point thickness. (Chin J Ophthalmol, 2018

  3. SEMIAUTOMATED SOLID-PHASE EXTRACTION PROCEDURE FOR DRUG SCREENING IN BIOLOGICAL-FLUIDS USING THE ASPEC SYSTEM IN COMBINATION WITH CLEAN SCREEN DAU COLUMNS

    NARCIS (Netherlands)

    CHEN, XH; FRANKE, JP; ENSING, K; WIJSBEEK, J; DEZEEUW, RA

    1993-01-01

    The use of a semi-automated solid-phase extraction system (ASPEC) for the screening of drugs in plasma and urine on a single mixed-mode column (Clean Screen DAU) is described. The processes of column preconditioning, sample application, column wash, pH adjustment and elution of the drugs were

  4. Development of a keratinocyte-based screening model for antipsoriatic drugs using green fluorescent protein under the control of an endogenous promoter.

    Science.gov (United States)

    Pol, Arno; van Ruissen, Fred; Schalkwijk, Joost

    2002-08-01

    Inflamed epidermis (psoriasis, wound healing, ultraviolet-irradiated skin) harbors keratinocytes that are hyperproliferative and display an abnormal differentiation program. A distinct feature of this so-called regenerative maturation pathway is the expression of proteins such as the cytokeratins CK6, CK16, and CK17 and the antiinflammatory protein SKALP/elafin. These proteins are absent in normal skin but highly induced in lesional psoriatic skin. Expression of these genes can be used as a surrogate marker for psoriasis in drug-screening procedures of large compound libraries. The aim of this study was to develop a keratinocyte cell line that contained a reporter gene under the control of a psoriasis-associated endogenous promoter and demonstrate its use in an assay suitable for screening. We generated a stably transfected keratinocyte cell line that expresses enhanced green fluorescent protein (EGFP), under the control of a 0.8-kb fragment derived from the promoter of the SKALP/elafin gene, which confers high levels of tissue-specific expression at the mRNA level. Induction of the SKALP promoter by tumor necrosis factor-alpha resulted in increased expression levels of the secreted SKALP-EGFP fusion protein as assessed by direct readout of fluorescence and fluorescence polarization in 96-well cell culture plates. The fold stimulation of the reporter gene was comparable to that of the endogenous SKALP gene as assessed by enzyme-linked immunosorbent assay. Although the dynamic range of the screening system is limited, the small standard deviation yields a Z factor of 0.49. This indicates that the assay is suitable as a high-throughput screen, and provides proof of the concept that a secreted EGFP fusion protein under the control of a physiologically relevant endogenous promoter can be used as a fluorescence-based high-throughput screen for differentiation-modifying or antiinflammatory compounds that act via the keratinocyte.

  5. Speed and speed classes of film-screen systems

    International Nuclear Information System (INIS)

    Borcke, E.

    1989-01-01

    In order to carry out the DIN 6868, Part 50 (1988) acceptance test within the framework of measures of quality assurance, the dose of the film-screen combination used is needed in the plane of the cassette. Recent methods for determination of sensitivity use the film-screen system instead of artificial light and decisions can be made as to the dose of the cassette plane. In order to characterize the sensitivity, it is proposed to use a given scale of numbers for the sensitivity S in increments of Δ log S = 0.05 in numerical values. It will also be useful for practical purposes to employ the ''sensitivity class'' with 2-fold increments in order to bring the planned radiological specifications into agreement with the demands of the user. (author)

  6. Speed and speed classes of film-screen systems

    International Nuclear Information System (INIS)

    Borcke, E.

    1989-01-01

    In order to carry out the DIN 6868, Part 50(1988) acceptance test within the framework of measures of quality assurance, the dose of the film-screen combination used is needed in the plane of the cassette. Recent methods for determination of sensitivity use the film-screen system instead of artificial light and decisions can be made as to the dose of the cassette plane. In order to characterize the sensitivity, it is proposed to use a given scale of numbers for the sensitivity S in increments of Δ log S = 0.05 in numerical values. It will also be useful for practical purposes to employ the ''sensitivity class'' with 2-fold increments in order to bring the planned radiological specifications into agreement with the demands of the user. (author)

  7. An expert display system and nuclear power plant control rooms

    International Nuclear Information System (INIS)

    Beltracchi, L.

    1988-01-01

    An expert display system controls automatically the display of segments on a cathode ray tube's screen to form an image of plant operations. The image consists of an icon of: 1) the process (heat engine cycle), 2) plant control systems, and 3) safety systems. A set of data-driven, forward-chaining computer stored rules control the display of segments. As plant operation changes, measured plant data are processed through the rules, and the results control the deletion and addition of segments to the display format. The icon contains information needed by control rooms operators to monitor plant operations. One example of an expert display is illustrated for the operator's task of monitoring leakage from a safety valve in a steam line of a boiling water reactor (BWR). In another example, the use of an expert display to monitor plant operations during pre-trip, trip, and post-trip operations is discussed as a universal display. The viewpoints and opinions expressed herein are the author's personal ones, and they are not to be interpreted as Nuclear Regulatory Commission criteria, requirements, or guidelines

  8. Proposal to institutionalize criteria and quality standards for cervical cancer screening within a health care system

    Directory of Open Access Journals (Sweden)

    Salmerón-Castro Jorge

    1998-01-01

    Full Text Available The uterine cervix is the most common cancer site for females. Approximately 52,000 new cases occur annually in Latin America, thus the need to improve efficiency and effectiveness of Cervical Cancer Screening Programs (CCSP is mandatory to decrease the unnecessary suffering women must bear. This paper is addressing essential issues to revamp the CCSP as proposed by the Mexican official norm. A general framework for institutionaling CCSP is outlined. Furthermore, strategies to strengthen CCSP performance through managerial strategies and quality assurance activities are described. The focus is on the following activities: 1 improving coverage; 2 implementing smear-taking quality control; 3 improving quality in interpretation of Pap test; 4 guaranteeing treatment for women for whom abnormalities are detected; 5 improving follow-up; 6 development of quality control measures and 7 development of monitoring and epidemiological surveillance information systems. Changes within the screening on cervical cancer may be advocated as new technologies present themselves and shortcomings in the existing program appear. It is crucial that these changes should be measured through careful evaluation in order to tally up potential benefits.

  9. Estimating the Impacts of Direct Load Control Programs Using GridPIQ, a Web-Based Screening Tool

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Seemita; Thayer, Brandon L.; Barrett, Emily L.; Studarus, Karen E.

    2017-11-13

    In direct load control (DLC) programs, utilities can curtail the demand of participating loads to contractually agreed-upon levels during periods of critical peak load, thereby reducing stress on the system, generation cost, and required transmission and generation capacity. Participating customers receive financial incentives. The impacts of implementing DLC programs extend well beyond peak shaving. There may be a shift of load proportional to the interrupted load to the times before or after a DLC event, and different load shifts have different consequences. Tools that can quantify the impacts of such programs on load curves, peak demand, emissions, and fossil fuel costs are currently lacking. The Grid Project Impact Quantification (GridPIQ) screening tool includes a Direct Load Control module, which takes into account project-specific inputs as well as the larger system context in order to quantify the impacts of a given DLC program. This allows users (utilities, researchers, etc.) to test and compare different program specifications and their impacts.

  10. School-based intervention on healthy behaviour among Ecuadorian adolescents: effect of a cluster-randomized controlled trial on screen-time.

    Science.gov (United States)

    Andrade, Susana; Verloigne, Maïté; Cardon, Greet; Kolsteren, Patrick; Ochoa-Avilés, Angelica; Verstraeten, Roosmarijn; Donoso, Silvana; Lachat, Carl

    2015-09-22

    Effective interventions on screen-time behaviours (television, video games and computer time) are needed to prevent non-communicable diseases in low- and middle-income countries. The present manuscript investigates the effect of a school-based health promotion intervention on screen-time behaviour among 12- to 15-year-old adolescents. We report the effect of the trial on screen-time after two stages of implementation. We performed a cluster-randomised pair matched trial in urban schools in Cuenca-Ecuador. Participants were adolescents of grade eight and nine (mean age 12.8 ± 0.8 years, n = 1370, control group n = 684) from 20 schools (control group n = 10). The intervention included an individual and environmental component tailored to the local context and resources. The first intervention stage focused on diet, physical activity and screen-time behaviour, while the second stage focused only on diet and physical activity. Screen-time behaviours, primary outcome, were assessed at baseline, after the first (18 months) and second stage (28 months). Mixed linear models were used to analyse the data. After the first stage (data from n = 1224 adolescents; control group n = 608), the intervention group had a lower increase in TV-time on a week day (β = -15.7 min; P = 0.003) and weekend day (β = -18.9 min; P = 0.005), in total screen-time on a weekday (β = -25.9 min; P = 0.03) and in the proportion of adolescents that did not meet the screen-time recommendation (β = -4 percentage point; P = 0.01), compared to the control group. After the second stage (data from n = 1078 adolescents; control group n = 531), the TV-time on a weekday (β = 13.1 min; P = 0.02), and total screen-time on a weekday (β = 21.4 min; P = 0.03) increased more in adolescents from the intervention group. No adverse effects were reported. A multicomponent school-based intervention was only able to mitigate the increase

  11. Scada SystemsControl, Supervision and Data Acquisition for the Power Plants Settled on a Stream (Part 2

    Directory of Open Access Journals (Sweden)

    Cosmin Ursoniu

    2015-09-01

    Full Text Available Scada (supervisory control and data acquisition is a complex system that supervises and controls an industrial process and performs several functions. A human machine interface will also be presented and how the process in a power plant is controlled and supervised through it by the operator. The main screen will be described (which is a global view of the hydro unit and what the operator can see and what he can press to control the power plants process also a few more screens will be presented for auxiliary installations and it will be described what the operator can see and what he can do to control the installation.

  12. Scada SystemsControl, Supervision and Data Acquisition for the Power Plants Settled on a Stream (Part 1

    Directory of Open Access Journals (Sweden)

    Cosmin Ursoniu

    2015-09-01

    Full Text Available Scada (supervisory control and data acquisition is a complex system that supervises and control an industrial process and performs several functions. A human machine interface will also be presented and how the process in a power plant is controlled and supervised through it by the operator. The main screen will be described (which is a global view of the hydro unit and what the operator can see and what he can press to control the power plants process also a few more screens will be presented for auxiliary installations and it will be described what the operator can see and what he can do to control the installation.

  13. State of affairs of tuberculosis in prison facilities: a systematic review of screening practices and recommendations for best TB control

    NARCIS (Netherlands)

    Vinkeles Melchers, Natalie V. S.; van Elsland, Sabine L.; Lange, Joep M. A.; Borgdorff, Martien W.; van den Hombergh, Jan

    2013-01-01

    Prisoners are at high risk of developing tuberculosis (TB), causing morbidity and mortality. Prison facilities encounter many challenges in TB screening procedures and TB control. This review explores screening practices for detection of TB and describes limitations of TB control in prison

  14. Advanced control system for the Integral Fast Reactor fuel pin processor

    International Nuclear Information System (INIS)

    Lau, L.D.; Randall, P.F.; Benedict, R.W.; Levinskas, D.

    1993-01-01

    A computerized control system has been developed for the remotely-operated fuel pin processor used in the Integral Fast Reactor Program, Fuel Cycle Facility (FCF). The pin processor remotely shears cast EBR- reactor fuel pins to length, inspects them for diameter, straightness, length, and weight, and then inserts acceptable pins into new sodium-loaded stainless-steel fuel element jackets. Two main components comprise the control system: (1) a programmable logic controller (PLC), together with various input/output modules and associated relay ladder-logic associated computer software. The PLC system controls the remote operation of the machine as directed by the OCS, and also monitors the machine operation to make operational data available to the OCS. The OCS allows operator control of the machine, provides nearly real-time viewing of the operational data, allows on-line changes of machine operational parameters, and records the collected data for each acceptable pin on a central data archiving computer. The two main components of the control system provide the operator with various levels of control ranging from manual operation to completely automatic operation by means of a graphic touch screen interface

  15. Effectiveness of school dental screening on stimulating dental attendance rates in Vikarabad town: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Gadde Praveen

    2014-01-01

    Full Text Available Background: The school dental screening program has been in existence from the beginning of 20 th century. Its value in encouraging attendance among school children is not fully established. Aim: The aim was to determine the effectiveness of school dental screening on stimulating dental attendance rates among school children in Vikarabad town. Objectives: (a To compare the dental attendance rates between 6-9 and 10-13 years old age groups, among male and female school children in Vikarabad town. (b To identify the type of dental treatment received by the school children. Materials and Methods: A randomized controlled trial was conducted among school children aged 6-13 years old from 16 schools that were randomly selected and divided into two groups. Eight schools had a dental screening program (study group = 300 children and had blanket referral cards and 8 schools that did not have the intervention (control group = 300. The dental attendance rates were determined after 3 months of follow-up period by evaluating the blanket referral cards for the study group and by an oral questionnaire for the control group. Results: The dental attendance rate was 27% for the study group and 18% for the control group which is statistically significant. The attendance rate was higher among 10-13 years of children both in test group and control groups. Among the children who visited the dentist, 53% in the control group and 69% from the test group got simple amalgam and glass ionomer cement restorations. Conclusion: The dental attendance rates were improved following school dental screening.

  16. BACTEC MGIT 960 TM system for screening of Mycobacterium ...

    African Journals Online (AJOL)

    This study was aimed to evaluate the recent technique (BACTEC MGIT 960 TM system) for screening of Mycobacterium tuberculosis complex among cattle in Egypt. From the 1180 cattle examined in three different Governorates (El-Sharkia, El-Gharbia and El-Monefeia) by single intradermal tuberculin test, 29 animals ...

  17. Results of a lay health education intervention to increase colorectal cancer screening among Filipino Americans: A cluster randomized controlled trial.

    Science.gov (United States)

    Cuaresma, Charlene F; Sy, Angela U; Nguyen, Tung T; Ho, Reginald C S; Gildengorin, Ginny L; Tsoh, Janice Y; Jo, Angela M; Tong, Elisa K; Kagawa-Singer, Marjorie; Stewart, Susan L

    2018-04-01

    Filipino colorectal cancer (CRC) screening rates fall below Healthy People 2020 goals. In this study, the authors explore whether a lay health educator (LHE) approach can increase CRC screening among Filipino Americans ages 50 to 75 years in Hawai'i. A cluster randomized controlled trial from 2012 through 2015 compared an intervention, which consisted of LHEs delivering 2 education sessions and 2 telephone follow-up calls on CRC screening plus a CRC brochure versus an attention control, in which 2 lectures and 2 follow-up calls on nutrition and physical activity plus a CRC brochure were provided. The primary outcome was change in self-reported ever receipt of CRC screening at 6 months. Among 304 participants (77% women, 86% had > 10 years of residence in the United States), the proportion of participants who reported ever having received CRC screening increased significantly in the intervention group (from 80% to 89%; P = .0003), but not in the control group (from 73% to 74%; P = .60). After covariate adjustment, there was a significant intervention effect (odds ratio, 1.9; 95% confidence interval, 1.0-3.5). There was no intervention effect on up-to-date screening. This first randomized controlled trial for CRC screening among Hawai'i's Filipinos used an LHE intervention with mixed, but promising, results. Cancer 2018;124:1535-42. © 2018 American Cancer Society. © 2018 American Cancer Society.

  18. A Fully Automated High-Throughput Flow Cytometry Screening System Enabling Phenotypic Drug Discovery.

    Science.gov (United States)

    Joslin, John; Gilligan, James; Anderson, Paul; Garcia, Catherine; Sharif, Orzala; Hampton, Janice; Cohen, Steven; King, Miranda; Zhou, Bin; Jiang, Shumei; Trussell, Christopher; Dunn, Robert; Fathman, John W; Snead, Jennifer L; Boitano, Anthony E; Nguyen, Tommy; Conner, Michael; Cooke, Mike; Harris, Jennifer; Ainscow, Ed; Zhou, Yingyao; Shaw, Chris; Sipes, Dan; Mainquist, James; Lesley, Scott

    2018-05-01

    The goal of high-throughput screening is to enable screening of compound libraries in an automated manner to identify quality starting points for optimization. This often involves screening a large diversity of compounds in an assay that preserves a connection to the disease pathology. Phenotypic screening is a powerful tool for drug identification, in that assays can be run without prior understanding of the target and with primary cells that closely mimic the therapeutic setting. Advanced automation and high-content imaging have enabled many complex assays, but these are still relatively slow and low throughput. To address this limitation, we have developed an automated workflow that is dedicated to processing complex phenotypic assays for flow cytometry. The system can achieve a throughput of 50,000 wells per day, resulting in a fully automated platform that enables robust phenotypic drug discovery. Over the past 5 years, this screening system has been used for a variety of drug discovery programs, across many disease areas, with many molecules advancing quickly into preclinical development and into the clinic. This report will highlight a diversity of approaches that automated flow cytometry has enabled for phenotypic drug discovery.

  19. Validation of the Federal Aviation Administration Air Traffic Control Specialist Pre-Training Screen.

    Science.gov (United States)

    1994-02-01

    Two formal validation studies of the Air Traffic Control Specialist Pre Training Screen (ATCS/PTS), a 5 day computer administered test battery, are described. The ATCS/PTS was designed to replace the 9 week US Federal Aviation Administration (FAA) Ac...

  20. Physical and Clinical Comparison between a Screen-Film System and a Dual-Side Reading Mammography-Dedicated Computed Radiography System

    International Nuclear Information System (INIS)

    Rivetti, S.; Canossi, B.; Battista, R.; Vetruccio, E.; Torricelli, P.; Lanconelli, N.; Danielli, C.; Borasi, G.

    2009-01-01

    Background: Digital mammography systems, thanks to a physical performance better than conventional screen-film units, have the potential of reducing the dose to patients, without decreasing the diagnostic accuracy. Purpose: To achieve a physical and clinical comparison between two systems: a screen-film plate and a dual-side computed radiography system (CRM; FUJIFILM FCR 5000 MA). Material and Methods: A unique feature of the FCR 5000 MA system is that it has a clear support medium, allowing light emitted during the scanning process to be detected on the 'back' of the storage phosphor plate, considerably improving the system's efficiency. The system's physical performance was tested by means of a quantitative analysis, with calculation of the modulation transfer function, detective quantum efficiency, and contrast-detail analysis; subsequently, the results were compared with those achieved using a screen-film system (SFM; Eastmann Kodak MinR-MinR 2000). A receiver operating characteristic (ROC) analysis was then performed on 120 paired clinical images obtained in a craniocaudal projection with the conventional SFM system under standard exposure conditions and also with the CRM system working with a dose reduced by 35% (average breast thickness: 4.3 cm; mean glandular dose: 1.45 mGy). CRM clinical images were interpreted both in hard copy and in soft copy. Results: The ROC analysis revealed that the performances of the two systems (SFM and CRM with reduced dose) were similar (P>0.05): the diagnostic accuracy of the two systems, when valued in terms of the area underneath the ROC curve, was found to be 0.74 for the SFM, 0.78 for the CRM (hard copy), and 0.79 for the CRM (soft copy). Conclusion: The outcome obtained from our experiments shows that the use of the dual-side CRM system is a very good alternative to the screen-film system

  1. Quality control in screening programs for cervical cancer; Control de la calidad en los programas de pesquisa de cancer cervicouterino

    Energy Technology Data Exchange (ETDEWEB)

    Sarduy Napoles, Miguel, E-mail: miguel.sarduy@infomed.sld.cu [Centro de Investigaciones Medico Quirurgicas, La Habana (Cuba)

    2012-07-01

    The malignancy of the cervix is one of the few locations avoidable cancers, if detected before it progresses to the infiltration. The most efficient way of early detection is through a screening program to provide women undertaking a regular and quality Pap smear. If this test results abnormal, the program offers easier access to specialized care, effective treatment, and follow-up. The objective of this article is to present usefulness of methods for quality control used in screening programs for cervical cancer to detect their inadequacies. Here are some factors and conditions that must be considered in each of the steps to take, for a cervical cancer screening program to be successful and to meet the objectives proposed in reducing mortality due to this cause. This document contains some useful indexes calculated to ensure quality throughout the process. There should be the measurement of quality throughout the screening process that allows collecting of reliable data as well as correcting deficiencies

  2. Association between cervical screening and prevention of invasive cervical cancer in Ontario: a population-based case-control study.

    Science.gov (United States)

    Vicus, Danielle; Sutradhar, Rinku; Lu, Yan; Kupets, Rachel; Paszat, Lawrence

    2015-01-01

    The aim of this study was to estimate the effect of cervical screening in the prevention of invasive cervical cancer among age groups, using a population-based case-control study in the province of Ontario, Canada. Exposure was defined as cervical cytology history greater than 3 months before the diagnosis date of cervical cancer (index date). Cases were women who were diagnosed with cervical cancer between January 1, 1998, and December 31, 2008. Controls were women without a diagnosis of cervical cancer on, or before, December 31, 2008. Two controls were matched to each case on year of birth and income quintile, as of the index date. Conditional logistic regression was used to estimate the odds ratio for having been screened among those with cervical cancer. Cervical cancer screening performed between 3 and 36 months before the index date was protective against invasive cervical cancer in women aged 40 through 69 years. In women younger than 40 years, cervical cancer screening performed 3 to 36 months before the index date was not protective. Cervical screening is associated with a reduced risk for invasive cervical cancer among women older than 40 years. Cervical cancer resources should be focused on maximizing the risk reduction.

  3. Further Screening of Entomopathogenic Fungi and Nematodes as Control Agents for Drosophila suzukii.

    Science.gov (United States)

    Cuthbertson, Andrew G S; Audsley, Neil

    2016-06-09

    Drosophila suzukii populations remain low in the UK. To date, there have been no reports of widespread damage. Previous research demonstrated that various species of entomopathogenic fungi and nematodes could potentially suppress D. suzukii population development under laboratory trials. However, none of the given species was concluded to be specifically efficient in suppressing D. suzukii. Therefore, there is a need to screen further species to determine their efficacy. The following entomopathogenic agents were evaluated for their potential to act as control agents for D. suzukii: Metarhizium anisopliae; Isaria fumosorosea; a non-commercial coded fungal product (Coded B); Steinernema feltiae, S. carpocapsae, S. kraussei and Heterorhabditis bacteriophora. The fungi were screened for efficacy against the fly on fruit while the nematodes were evaluated for the potential to be applied as soil drenches targeting larvae and pupal life-stages. All three fungi species screened reduced D. suzukii populations developing from infested berries. Isaria fumosorosea significantly (p nematodes significantly reduced adult emergence from pupal cases compared to the water control. Larvae proved more susceptible to nematode infection. Heterorhabditis bacteriophora proved the best from the four nematodes investigated; readily emerging from punctured larvae and causing 95% mortality. The potential of the entomopathogens to suppress D. suzukii populations is discussed.

  4. Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography

    International Nuclear Information System (INIS)

    Shimamoto, Kazuhiro; Ikeda, Mitsuru; Satake, Hiroko; Ishigaki, Satoko; Sawaki, Akiko; Ishigaki, Takeo

    2002-01-01

    Our objective was to evaluate interobserver agreement and to compare the performance score in quality control of screen-film mammography and computed radiography (CR) using a breast phantom. Eleven radiologists interpreted a breast phantom image (CIRS model X) by four viewing methods: (a) original screen-film; (b) soft-copy reading of the digitized film image; (c) hard-copy reading of CR using an imaging plate; and (d) soft-copy reading of CR. For the soft-copy reading, a 17-in. CRT monitor (1024 x 1536 x 8 bits) was used. The phantom image was evaluated using a scoring system outlined in the instruction manual, and observers judged each object using a three-point rating scale: (a) clearly seen; (b) barely seen; and (c) not seen. For statistical analysis, the kappa statistic was employed. For ''mass'' depiction, interobserver agreement using CR was significantly lower than when using screen-film (p<0.05). There was no significant difference in the kappa value for detecting ''microcalcification''; however, the performance score of ''microcalcification'' on CR hard-copy was significantly lower than on the other three viewing methods (p<0.05). Viewing methods (film or CR, soft-copy or hard-copy) could affect how the phantom image is judged. Paying special attention to viewing conditions is recommended for quality control of CR mammograms. (orig.)

  5. Improving rates of screening and prevention by leveraging existing information systems.

    Science.gov (United States)

    Neil, Nancy

    2003-11-01

    In 1997 Virginia Mason Health System (VMMC), a vertically integrated hospital and multispecialty group practice, had no process or system to deliver the right patient clinical data, in the right form, at the right place--when providers needed it for effective patient care. Without any new investment in technology, a work group of five individuals leveraged existing, primarily paper-based information systems to launch development and implementation of a provider prompting tool--a primary care and prevention (PCP) report--which prompted providers to complete screening, prevention, and disease management services at every patient appointment. The work group developed and pilot tested the report and created a mechanism by which the report could be delivered just in time before each patient's appointment. The report integrated information from independent appointment scheduling, laboratory results reporting, patient demographics, and billing data sources. MEASURING THE PCP REPORT'S IMPACT: The results of two separate analyses demonstrate improvement in rates of screening and prevention across VMMC soon after the PCP report became available. These results led senior leadership to make the PCP report's utilization a systemwide imperative. The PCP report is used by nearly all primary care providers as a prompt to complete screening, prevention, and disease management services at every patient appointment.

  6. Informing men about prostate cancer screening: a randomized controlled trial of patient education materials.

    Science.gov (United States)

    Ilic, Dragan; Egberts, Kristine; McKenzie, Joanne E; Risbridger, Gail; Green, Sally

    2008-04-01

    Patient education materials can assist patient decision making on prostate cancer screening. To explore the effectiveness of presenting health information on prostate cancer screening using video, internet, and written interventions on patient decision making, attitudes, knowledge, and screening interest. Randomized controlled trial. A total of 161 men aged over 45, who had never been screened for prostate cancer, were randomized to receive information on prostate cancer screening. Participants were assessed at baseline and 1-week postintervention for decisional conflict, screening interest, knowledge, anxiety, and decision-making preference. A total of 156 men were followed-up at 1-week postintervention. There was no statistical, or clinical, difference in mean change in decisional conflict scores between the 3 intervention groups (video vs internet -0.06 [95% CI -0.24 to 0.12]; video vs pamphlet 0.04 [95%CI -0.15 to 0.22]; internet vs pamphlet 0.10 [95%CI -0.09 to 0.28]). There was also no statistically significant difference in mean knowledge, anxiety, decision-making preference, and screening interest between the 3 intervention groups. Results from this study indicate that there are no clinically significant differences in decisional conflict when men are presented health information on prostate cancer screening via video, written materials, or the internet. Given the equivalence of the 3 methods, other factors need to be considered in deciding which method to use. Health professionals should provide patient health education materials via a method that is most convenient to the patient and their preferred learning style.

  7. Screening Air Traffic Control Specialists for Psychopathology Using the Minnesota Multiphasic Personality Inventory-2

    National Research Council Canada - National Science Library

    King, Raymond E; Schroeder, David J; Manning, Carol A; Retzlaff, Paul D; Williams, Clara A

    2008-01-01

    ...) as a psychological screening tool for conditionally selected FAA Air Traffic Control Specialists (ATCSs). A sample of 1,014 ATCSs in training voluntarily completed the MMPI-2 as part of a research program...

  8. Establishing a New Screening System for Mild Cognitive Impairment and Alzheimer's Disease with Mental Rotation Tasks that Evaluate Visuospatial Function.

    Science.gov (United States)

    Suzuki, Ayuko; Shinozaki, Jun; Yazawa, Shogo; Ueki, Yoshino; Matsukawa, Noriyuki; Shimohama, Shun; Nagamine, Takashi

    2018-01-01

    The mental rotation task is well-known for the assessment of visuospatial function; however, it has not been used for screening of dementia patients. The aim of this study was to create a simple screening test for patients with mild cognitive impairment (MCI) and Alzheimer's disease (AD) by focusing on non-amnestic symptoms. Age-matched healthy controls (age 75.3±6.8), patients with MCI (76.5±5.5), and AD (78.2±5.0) participated in this study. They carried out mental rotation tasks targeting geometric graphics or alphabetical characters with three rotating angles (0°, 90°, and 180°) and indicated the correct answer. Response accuracy and reaction time were recorded along with their eye movements using an eye tracker. To quantify their visual processing strategy, the run count ratio (RC ratio) was calculated by dividing the mean number of fixations in incorrect answers by that in correct answers. AD patients showed lower accuracy and longer reaction time than controls. They also showed a significantly greater number of fixation and smaller saccade amplitude than controls, while fixation duration did not differ significantly. The RC ratio was higher for AD, followed by MCI and control groups. By setting the cut-off value to 0.47 in the 180° rotating angle task, we could differentiate MCI patients from controls with a probability of 80.0%. We established a new screening system for dementia patients by evaluating visuospatial function. The RC ratio during a mental rotation task is useful for discriminating MCI patients from controls.

  9. Quality study of portal images acquired by computed radiography and screen-film system under megavoltage ray

    International Nuclear Information System (INIS)

    Cao Guoquan; Jin Xiance; Wu Shixiu; Xie Congying; Zhang Li; Yu Jianyi; Li Yueqing

    2007-01-01

    Objective: To evaluate the quality of the portal images acquired by computed radiography (CR) system and conventional screen-film system, respectively. Methods: Imaging plates (IP) and X-ray films ora home-devised lead phantom with a leakage of 6.45% were acquired, and modulation transfer function (MTF) curves of the both images were measured using edge method. Portal images of 40 nasopharyngeal cancer patients were acquired by IP and screen-film system respectively. Two doctors with similar experience evaluated the damage degree of petrosal bone, the receiver operating characteristic (ROC) curve of CR images and general images were drawn according to two doctors evaluation results. Results: The identification frequency of CR system and screen-film system were 1.159 and 0.806 Lp/mm respectively. For doctor one, the area under ROC curve of CR images and general images were 0.802 and 0.742 respectively. For doctor two, the area under ROC curve of CR images and general images were 0.751 and 0.600 respectively. The MTF curve and ROC curve of CR are both better than those of screen-film system. Conclusion: The image quality of CR portal imaging is much better than that of screen-film system. The utility of CR in linear accelerator for portal imaging is promising in clinic. (authors)

  10. Screening of hypo virulence of Colletotrichum gloeosporioides and its control effect on apple anthracnose

    International Nuclear Information System (INIS)

    Li Na; Tan Genjia; Li Zenzhi; Liu Shufang; Hou Xiaodan; Yang Weilai

    2007-01-01

    The Colletotrichum gloeosporioides is a nosogenesis important fungus that causes the serious economic loss on apple, however, inducing resistance of the host may reduce the loss. Colletotrichum gloeosporioides was treated by ion implantation and by alternating magnetic field to induce aberrance. It was screened through eyeballing first, and then screened through growth on apple. Two aberrance strains (C100-2-5 and C0.25-1-2 were selected. Both the strains have good protective function and good effect to control the apple disease. (authors)

  11. PC-based arc ignition and arc length control system for gas tungsten arc welding

    International Nuclear Information System (INIS)

    Liu, Y.; Cook, G.E.; Barnett, R.J.; Springfield, J.F.

    1992-01-01

    In this paper, a PC-based digital control system for gas tungsten arc welding (GTAW) is presented. This system controls the arc ignition process, the arc length, and the process of welding termination. A DT2818 made by Data Translation is used for interface and A/D and D/A conversions. The digital I/O ports of the DT2818 are used for control of wirefeed, shield gas, cooling water, welding power supply, etc. The DT2818 is housed in a PC. The welding signals and status are displayed on the screen for in-process monitoring. A user can control the welding process by the keyboard

  12. Human factors guidelines for large-screen displays

    International Nuclear Information System (INIS)

    Collier, Steve

    2005-09-01

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  13. Human factors guidelines for large-screen displays

    Energy Technology Data Exchange (ETDEWEB)

    Collier, Steve

    2005-09-15

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  14. Incentives in Diabetic Eye Assessment by Screening (IDEAS): study protocol of a three-arm randomized controlled trial using financial incentives to increase screening uptake in London.

    Science.gov (United States)

    Judah, Gaby; Vlaev, Ivo; Gunn, Laura; King, Dominic; King, Derek; Valabhji, Jonathan; Darzi, Ara; Bicknell, Colin

    2016-03-18

    Diabetes is an increasing public health problem in the UK and globally. Diabetic retinopathy is a microvascular complication of diabetes, and is one of the leading causes of blindness in the UK working age population. The diabetic eye screening programme in England aims to invite all people with diabetes aged 12 or over for retinal photography to screen for the presence of diabetic retinopathy. However, attendance rates are only 81 %, leaving many people at risk of preventable sight loss. This is a three arm randomized controlled trial to investigate the impact of different types of financial incentives (based on principles from behavioral economics) on increasing attendance at diabetic eye screening appointments in London. Eligible participants will be aged 16 or over, and are those who have been invited to screening appointments annually, but who have not attended, or telephoned to rearrange an appointment, within the last 24 months. Eligible participants will be randomized to one of three conditions: 1. Control condition (usual invitation letter) 2. Fixed incentive condition (usual invitation letter, including a voucher for £10 if they attend their appointment) 3. Probabilistic incentive condition (invitation letter, including a voucher for a 1 in 100 chance of winning £1000 if they attend their appointment). Participants will be sent invitation letters, and the primary outcome will be whether or not they attend their appointment. One thousand participants will be included in total, randomized with a ratio of 1.4:1:1. In order to test whether the incentive scheme has a differential impact on patients from different demographic or socio-economic groups, information will be recorded on age, gender, distance from screening center, socio-economic status and length of time since they were last screened. A cost-effectiveness analysis will also be performed. This study will be the first trial of financial incentives for improving uptake of diabetic eye screening. If

  15. Diagnosis System for Diabetic Retinopathy and Glaucoma Screening to Prevent Vision Loss

    Directory of Open Access Journals (Sweden)

    Siva Sundhara Raja DHANUSHKODI

    2014-03-01

    Full Text Available Aim: Diabetic retinopathy (DR and glaucoma are two most common retinal disorders that are major causes of blindness in diabetic patients. DR caused in retinal images due to the damage in retinal blood vessels, which leads to the formation of hemorrhages spread over the entire region of retina. Glaucoma is caused due to hypertension in diabetic patients. Both DR and glaucoma affects the vision loss in diabetic patients. Hence, a computer aided development of diagnosis system for Diabetic retinopathy and Glaucoma screening is proposed in this paper to prevent vision loss. Method: The diagnosis system of DR consists of two stages namely detection and segmentation of fovea and hemorrhages. The diagnosis system of glaucoma screening consists of three stages namely blood vessel segmentation, Extraction of optic disc (OD and optic cup (OC region and determination of rim area between OD and OC. Results: The specificity and accuracy for hemorrhages detection is found to be 98.47% and 98.09% respectively. The accuracy for OD detection is found to be 99.3%. This outperforms state-of-the-art methods. Conclusion: In this paper, the diagnosis system is developed to classify the DR and glaucoma screening in to mild, moderate and severe respectively.

  16. Development of droplets‐based microfluidic systems for single­‐cell high‐throughput screening

    DEFF Research Database (Denmark)

    Chen, Jun; Jensen, Thomas Glasdam; Godina, Alexei

    2014-01-01

    High-throughput screening (HTS) plays an important role in the development of microbial cell factories. One of the most popular approaches is to use microplates combined with the application of robotics, liquid handling and sophisticated detection methods. However, these workstations require large...... investment, and a logarithmic increase to screen large combinatorial libraries over the decades also makes it gradually out of depth. Here, we are trying to develop a feasible high‐throughput system that uses microfluidics to compartmentalize a single cell for propagation and analysis in monodisperse...... picoliter aqueous droplets surround by an immiscible fluorinated oil phase. Our aim is to use this system to facilitate the screening process for both the biotechnology and food industry....

  17. Randomized controlled trial on effectiveness of ultrasonography screening for breast cancer in women aged 40-49 (J-START). Research design

    International Nuclear Information System (INIS)

    Ohuchi, Noriaki; Ishida, Takanori; Kawai, Masaaki; Narikawa, Yoko; Yamamoto, Seiichiro; Sobue, Tomotaka

    2011-01-01

    In cancer screening, it is essential to undertake effective screening with appropriate methodology, which should be supported by evidence of a reduced mortality rate. At present, mammography is the only method for breast cancer screening with such evidence. However, mammography does not achieve sufficient accuracy in breasts with high density at ages below 50. Although ultrasonography achieves better accuracy in Breast Cancer detection even in dense breasts, the effectiveness has not been verified. We have planned a randomized controlled trial to assess the effectiveness of ultrasonography in women aged 40-49, with a design to study 50,000 women with mammography and ultrasonography (intervention group), and 50,000 controls with mammography only (control group). The participants are scheduled to take second round screening with the same modality 2 years on. The primary endpoints are sensitivity and specificity, and the secondary endpoint is the rate of advanced breast cancers. (author)

  18. Fiber-optic surface-enhanced Raman system for field screening of hazardous compounds

    International Nuclear Information System (INIS)

    Ferrell, T.L.; Goudonnet, J.P.; Arakawa, E.T.; Reddick, R.C.; Gammage, R.B.; Haas, J.W.; James, D.R.; Wachter, E.A.

    1988-01-01

    Surface-enhanced Raman scattering permits identification of compounds adsorbed onto a metal microbase that is microlithographically produced with submicron resolution. Less than one percent of a monolayer of a Raman Active target compound offers a high signal-to-noise ratio. By depositing the microbase on the exterior of a fiber optic cable, convenient field screening or monitoring is permitted. By using highly effective microbases, it is possible to reduce laser power requirements sufficiently to allow an economical, but complete, system to be housed in a suitcase. We shall present details of SERS system of this type and shall show data on samples of interest in the screening of hazardous compounds

  19. Diagnostic value of digital radiography compared to conventional screen-film system combinations

    International Nuclear Information System (INIS)

    Krug, B.; Zaehringer, M.; Lackner, K.

    1997-01-01

    Digital projection radiography provides digital data in X-ray examinations, which used to be carried out by examinations screen-film system combinations. The technological basis and clinical performances of digital luminescent radiography (DLR) and digital radiography are reviewed. Digital projection radiography does not allow to reduce selenium exposure significantly, compared to screen-film system combinations. Digital luminescent radiography can be used for the entire spectrum of analogous projection radiography the only exception being extremely subtile structural changes. The clinical experiences with digital selenium radiography achieved so far in chest X-rays are promising and the technique is expected to be increasing used in other anatomic regions as well. (orig.) [de

  20. Interactive TV: Interaction and Control in Second-screen TV Consumption

    DEFF Research Database (Denmark)

    Fleury, Alexandre; Pedersen, Jakob Schou; Baunstrup, Mai

    2012-01-01

    The integration of television and mobile technologies are becoming a reality in today’s home media environments. In order to facilitate the development of future cross-platform broadcast TV services, this study investigated prompting and control strategies for a secondary device in front of the TV...... they preferred with which content. Overall, we found a clear preference for keeping interactive contents and prompting on the secondary device and broadcast TV content on the primary screen. The workshops generated numerous ideas concerning possible personalization of such service....

  1. Cancer screening delivery in persistent poverty rural counties.

    Science.gov (United States)

    Bennett, Kevin J; Pumkam, Chaiporn; Bellinger, Jessica D; Probst, Janice C

    2011-10-01

    Rural populations are diagnosed with cancer at different rate and stages than nonrural populations, and race/ethnicity as well as the area-level income exacerbates the differences. The purpose of this analysis was to explore cancer screening rates across persistent poverty rural counties, with emphasis on nonwhite populations. The 2008 Behavioral Risk Factor Surveillance System was used, combined with data from the Area Resource File (analytic n = 309 937 unweighted, 196 344 347 weighted). Unadjusted analysis estimated screening rates for breast, cervical, and colorectal cancer. Multivariate analysis estimated the odds of screening, controlling for individual and county-level effects. Rural residents, particularly those in persistent poverty counties, were less likely to be screened than urban residents. More African Americans in persistent poverty rural counties reported not having mammography screening (18.3%) compared to 15.9% of urban African Americans. Hispanics had low screening rates across all service types. Multivariate analysis continued to find disparities in screening rates, after controlling for individual and county-level factors. African Americans in persistent poverty rural counties were more likely to be screened for both breast cancer (odds ratio, 1.44; 95% confidence interval, 1.12-1.85) and cervical cancer (1.46; 1.07-1.99) when compared with urban whites. Disparities in cancer screening rates exist across not only race/ethnicity but also county type. These disparities cannot be fully explained by either individual or county-level effects. Programs have been successful in improving screening rates for African American women and should be expanded to target other vulnerable women as well as other services such as colorectal cancer screening.

  2. Further Screening of Entomopathogenic Fungi and Nematodes as Control Agents for Drosophila suzukii

    Directory of Open Access Journals (Sweden)

    Andrew G. S. Cuthbertson

    2016-06-01

    Full Text Available Drosophila suzukii populations remain low in the UK. To date, there have been no reports of widespread damage. Previous research demonstrated that various species of entomopathogenic fungi and nematodes could potentially suppress D. suzukii population development under laboratory trials. However, none of the given species was concluded to be specifically efficient in suppressing D. suzukii. Therefore, there is a need to screen further species to determine their efficacy. The following entomopathogenic agents were evaluated for their potential to act as control agents for D. suzukii: Metarhizium anisopliae; Isaria fumosorosea; a non-commercial coded fungal product (Coded B; Steinernema feltiae, S. carpocapsae, S. kraussei and Heterorhabditis bacteriophora. The fungi were screened for efficacy against the fly on fruit while the nematodes were evaluated for the potential to be applied as soil drenches targeting larvae and pupal life-stages. All three fungi species screened reduced D. suzukii populations developing from infested berries. Isaria fumosorosea significantly (p < 0.001 reduced population development of D. suzukii from infested berries. All nematodes significantly reduced adult emergence from pupal cases compared to the water control. Larvae proved more susceptible to nematode infection. Heterorhabditis bacteriophora proved the best from the four nematodes investigated; readily emerging from punctured larvae and causing 95% mortality. The potential of the entomopathogens to suppress D. suzukii populations is discussed.

  3. Greenhouse intelligent control system based on microcontroller

    Science.gov (United States)

    Zhang, Congwei

    2018-04-01

    As one of the hallmarks of agricultural modernization, intelligent greenhouse has the advantages of high yield, excellent quality, no pollution and continuous planting. Taking AT89S52 microcontroller as the main controller, the greenhouse intelligent control system uses soil moisture sensor, temperature and humidity sensors, light intensity sensor and CO2 concentration sensor to collect measurements and display them on the 12864 LCD screen real-time. Meantime, climate parameter values can be manually set online. The collected measured values are compared with the set standard values, and then the lighting, ventilation fans, warming lamps, water pumps and other facilities automatically start to adjust the climate such as light intensity, CO2 concentration, temperature, air humidity and soil moisture of the greenhouse parameter. So, the state of the environment in the greenhouse Stabilizes and the crop grows in a suitable environment.

  4. The Role of screening in the strongly correlated 2D systems

    CERN Document Server

    Hwang, E H

    2003-01-01

    We investigate recently observed experiments in the strongly correlated 2D systems (r sub s >> 1) (low-density 2D plasmons, metallic behaviour of 2D systems and frictional drag resistivity between two 2D hole layers). We compare them with our theoretical results calculated within a conventional Fermi liquid theory with RPA screening.

  5. Preimplantation genetic screening.

    Science.gov (United States)

    Harper, Joyce C

    2018-03-01

    Preimplantation genetic diagnosis was first successfully performed in 1989 as an alternative to prenatal diagnosis for couples at risk of transmitting a genetic or chromosomal abnormality, such as cystic fibrosis, to their child. From embryos generated in vitro, biopsied cells are genetically tested. From the mid-1990s, this technology has been employed as an embryo selection tool for patients undergoing in vitro fertilisation, screening as many chromosomes as possible, in the hope that selecting chromosomally normal embryos will lead to higher implantation and decreased miscarriage rates. This procedure, preimplantation genetic screening, was initially performed using fluorescent in situ hybridisation, but 11 randomised controlled trials of screening using this technique showed no improvement in in vitro fertilisation delivery rates. Progress in genetic testing has led to the introduction of array comparative genomic hybridisation, quantitative polymerase chain reaction, and next generation sequencing for preimplantation genetic screening, and three small randomised controlled trials of preimplantation genetic screening using these new techniques indicate a modest benefit. Other trials are still in progress but, regardless of their results, preimplantation genetic screening is now being offered globally. In the near future, it is likely that sequencing will be used to screen the full genetic code of the embryo.

  6. Membrane diffusion- and capillary blood volume measurements are not useful as screening tools for pulmonary arterial hypertension in systemic sclerosis: a case control study

    Directory of Open Access Journals (Sweden)

    Spreeuwenberg Marieke D

    2008-10-01

    Full Text Available Abstract Background There is no optimal screening tool for the assessment of pulmonary arterial hypertension (PAH in patients with systemic sclerosis (SSc. A decreasing transfer factor of the lung for CO (TLCO is associated with the development of PAH in SSc. TLCO can be partitioned into the diffusion of the alveolar capillary membrane (Dm and the capillary blood volume (Vc. The use of the partitioned diffusion to detect PAH in SSc is not well established yet. This study evaluates whether Dm and Vc could be candidates for further study of the use for screening for PAH in SSc. Methods Eleven SSc patients with PAH (SScPAH+, 13 SSc patients without PAH (SScPAH- and 10 healthy control subjects were included. Pulmonary function testing took place at diagnosis of PAH. TLCO was partitioned according to Roughton and Forster. As pulmonary fibrosis in SSc influences values of the (partitioned TLCO, these were adjusted for fibrosis score as assessed on HRCT. Results TLCO as percentage of predicted (% was lower in SScPAH+ than in SScPAH- (41 ± 7% vs. 63 ± 12%, p vs. 39 ± 12%, p Conclusion SScPAH+ patients have lower Dm% than SScPAH- patients. There are no correlations between Dm% and hemodynamic parameters of PAH in SScPAH+. These findings do not support further study of the role of partitioning TLCO in the diagnostic work- up for PAH in SSc.

  7. Effect of second timed appointments for non-attenders of breast cancer screening in England: a randomised controlled trial.

    Science.gov (United States)

    Allgood, Prue C; Maroni, Roberta; Hudson, Sue; Offman, Judith; Turnbull, Anne E; Peacock, Lesley; Steel, Jim; Kirby, Geraldine; Ingram, Christine E; Somers, Julie; Fuller, Clare; Threlfall, Anthony G; Gabe, Rhian; Maxwell, Anthony J; Patnick, Julietta; Duffy, Stephen W

    2017-07-01

    In England, participation in breast cancer screening has been decreasing in the past 10 years, approaching the national minimum standard of 70%. Interventions aimed at improving participation need to be investigated and put into practice to stop this downward trend. We assessed the effect on participation of sending invitations for breast screening with a timed appointment to women who did not attend their first offered appointment within the NHS Breast Screening Programme (NHSBSP). In this open, randomised controlled trial, women in six centres in the NHSBSP in England who were invited for routine breast cancer screening were randomly assigned (1:1) to receive an invitation to a second appointment with fixed date and time (intervention) or an invitation letter with a telephone number to call to book their new screening appointment (control) in the event of non-attendance at the first offered appointment. Randomisation was by SX number, a sequential unique identifier of each woman within the NHSBSP, and at the beginning of the study a coin toss decided whether women with odd or even SX numbers would be allocated to the intervention group. Women aged 50-70 years who did not attend their first offered appointment were eligible for the analysis. The primary endpoint was participation (ie, attendance at breast cancer screening) within 90 days of the date of the first offered appointment; we used Poisson regression to compare the proportion of women who participated in screening in the study groups. All analyses were by intention to treat. This trial is registered with Barts Health, number 009304QM. We obtained 33 146 records of women invited for breast cancer screening at the six centres between June 2, 2014, and Sept 30, 2015, who did not attend their first offered appointment. 26 054 women were eligible for this analysis (12 807 in the intervention group and 13 247 in the control group). Participation within 90 days of the first offered appointment was

  8. Development of process control capability through the Browns Ferry Integrated Computer System using Reactor Water Clanup System as an example. Final report

    International Nuclear Information System (INIS)

    Smith, J.; Mowrey, J.

    1995-12-01

    This report describes the design, development and testing of process controls for selected system operations in the Browns Ferry Nuclear Plant (BFNP) Reactor Water Cleanup System (RWCU) using a Computer Simulation Platform which simulates the RWCU System and the BFNP Integrated Computer System (ICS). This system was designed to demonstrate the feasibility of the soft control (video touch screen) of nuclear plant systems through an operator console. The BFNP Integrated Computer System, which has recently. been installed at BFNP Unit 2, was simulated to allow for operator control functions of the modeled RWCU system. The BFNP Unit 2 RWCU system was simulated using the RELAP5 Thermal/Hydraulic Simulation Model, which provided the steady-state and transient RWCU process variables and simulated the response of the system to control system inputs. Descriptions of the hardware and software developed are also included in this report. The testing and acceptance program and results are also detailed in this report. A discussion of potential installation of an actual RWCU process control system in BFNP Unit 2 is included. Finally, this report contains a section on industry issues associated with installation of process control systems in nuclear power plants

  9. Does routine psychosocial screening improve referral to psychosocial care providers and patient-radiotherapist communication? A cluster randomized controlled trial.

    Science.gov (United States)

    Braeken, Anna P B M; Lechner, Lilian; Eekers, Daniëlle B P; Houben, Ruud M A; van Gils, Francis C J M; Ambergen, Ton; Kempen, Gertrudis I J M

    2013-11-01

    This study tests whether using a screening instrument improves referral to psychosocial care providers (e.g. psychologist) and facilitates patient-radiotherapist communication. A cluster randomized controlled trial was used. Fourteen radiotherapists were randomly allocated to the experimental or control group and 568 of their patients received care in accordance with the group to which their radiotherapist was allocated. Patients in the experimental group were asked to complete a screening instrument before and at the end of the radiation treatment period. All patients were requested to complete questionnaires concerning patient-physician communication after the first consultation and concerning psychosocial care 3 and 12 months post-intervention. Patients who completed the screening instrument were referred to social workers at an earlier stage than patients who did not (Pcommunication. Our results suggest that a simple screening procedure can be valuable for the timely treatment of psychosocial problems in patients. Future efforts should be directed at appropriate timing of screening and enhancing physicians' awareness regarding the importance of identifying, discussing and treating psychosocial problems in cancer patients. Psychosocial screening can be enhanced by effective radiotherapist-patient communication. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.

    Science.gov (United States)

    Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan

    2017-10-26

    Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.

  11. A Case-Control Study to Estimate the Impact of the Icelandic Population-Based Mammography Screening Program on Breast Cancer Death

    Energy Technology Data Exchange (ETDEWEB)

    Gabe, R.; Tryggvadottir, L.; Sigfusson, B.F.; Olafsdottir, G.H.; Sigurarsson , K. [Icelandic Cancer Society (Krabbameinsfelag Islands), Reykjavik (Iceland); Duffy, S.W. [Cancer Research UK, Centre for Epidemiology, Mathematics and Stati stics, Wolfson Inst. of Preventive Medicine, London (United Kingdom)

    2007-11-15

    Background: The Icelandic breast cancer screening program, initiated November 1987 in Reykjavik and covering the whole country from December 1989, comprises biennial invitation to mammography for women aged 40-69 years old. Purpose: To estimate the impact of mammography service screening in Iceland on deaths from breast cancer. Material and Methods: Cases were deaths from breast cancer from 1990 onwards in women aged 40 and over at diagnosis, during the period November 1987 to December 31, 2002. Age- and screening-area-matched, population-based controls were women who had also been invited to screening but were alive at the time their case died. Results: Using conditional logistic regression on the data from 226 cases and 902 controls, the odds ratio for the risk of death from breast cancer in those attending at least one screen compared to those never screened was 0.59 (95% CI 0.41-0.84). After adjustment for healthy-volunteer bias and screening-opportunity bias, the odds ratio was 0.65 (95% CI 0.39-1.09). Conclusion: These results indicate a 35-40% reduction in breast cancer deaths by attending the Icelandic breast cancer screening program. These results are consistent with the overall evidence from other observational evaluations of mammography-based programs.

  12. A Case-Control Study to Estimate the Impact of the Icelandic Population-Based Mammography Screening Program on Breast Cancer Death

    International Nuclear Information System (INIS)

    Gabe, R.; Tryggvadottir, L.; Sigfusson, B.F.; Olafsdottir, G.H.; Sigurarsson, K.; Duffy, S.W.

    2007-01-01

    Background: The Icelandic breast cancer screening program, initiated November 1987 in Reykjavik and covering the whole country from December 1989, comprises biennial invitation to mammography for women aged 40-69 years old. Purpose: To estimate the impact of mammography service screening in Iceland on deaths from breast cancer. Material and Methods: Cases were deaths from breast cancer from 1990 onwards in women aged 40 and over at diagnosis, during the period November 1987 to December 31, 2002. Age- and screening-area-matched, population-based controls were women who had also been invited to screening but were alive at the time their case died. Results: Using conditional logistic regression on the data from 226 cases and 902 controls, the odds ratio for the risk of death from breast cancer in those attending at least one screen compared to those never screened was 0.59 (95% CI 0.41-0.84). After adjustment for healthy-volunteer bias and screening-opportunity bias, the odds ratio was 0.65 (95% CI 0.39-1.09). Conclusion: These results indicate a 35-40% reduction in breast cancer deaths by attending the Icelandic breast cancer screening program. These results are consistent with the overall evidence from other observational evaluations of mammography-based programs

  13. Screensaver: an open source lab information management system (LIMS for high throughput screening facilities

    Directory of Open Access Journals (Sweden)

    Nale Jennifer

    2010-05-01

    Full Text Available Abstract Background Shared-usage high throughput screening (HTS facilities are becoming more common in academe as large-scale small molecule and genome-scale RNAi screening strategies are adopted for basic research purposes. These shared facilities require a unique informatics infrastructure that must not only provide access to and analysis of screening data, but must also manage the administrative and technical challenges associated with conducting numerous, interleaved screening efforts run by multiple independent research groups. Results We have developed Screensaver, a free, open source, web-based lab information management system (LIMS, to address the informatics needs of our small molecule and RNAi screening facility. Screensaver supports the storage and comparison of screening data sets, as well as the management of information about screens, screeners, libraries, and laboratory work requests. To our knowledge, Screensaver is one of the first applications to support the storage and analysis of data from both genome-scale RNAi screening projects and small molecule screening projects. Conclusions The informatics and administrative needs of an HTS facility may be best managed by a single, integrated, web-accessible application such as Screensaver. Screensaver has proven useful in meeting the requirements of the ICCB-Longwood/NSRB Screening Facility at Harvard Medical School, and has provided similar benefits to other HTS facilities.

  14. Screensaver: an open source lab information management system (LIMS) for high throughput screening facilities.

    Science.gov (United States)

    Tolopko, Andrew N; Sullivan, John P; Erickson, Sean D; Wrobel, David; Chiang, Su L; Rudnicki, Katrina; Rudnicki, Stewart; Nale, Jennifer; Selfors, Laura M; Greenhouse, Dara; Muhlich, Jeremy L; Shamu, Caroline E

    2010-05-18

    Shared-usage high throughput screening (HTS) facilities are becoming more common in academe as large-scale small molecule and genome-scale RNAi screening strategies are adopted for basic research purposes. These shared facilities require a unique informatics infrastructure that must not only provide access to and analysis of screening data, but must also manage the administrative and technical challenges associated with conducting numerous, interleaved screening efforts run by multiple independent research groups. We have developed Screensaver, a free, open source, web-based lab information management system (LIMS), to address the informatics needs of our small molecule and RNAi screening facility. Screensaver supports the storage and comparison of screening data sets, as well as the management of information about screens, screeners, libraries, and laboratory work requests. To our knowledge, Screensaver is one of the first applications to support the storage and analysis of data from both genome-scale RNAi screening projects and small molecule screening projects. The informatics and administrative needs of an HTS facility may be best managed by a single, integrated, web-accessible application such as Screensaver. Screensaver has proven useful in meeting the requirements of the ICCB-Longwood/NSRB Screening Facility at Harvard Medical School, and has provided similar benefits to other HTS facilities.

  15. PLC based development of control, monitoring and interlock for 100 kW, 45.6 MHz ICRH system

    International Nuclear Information System (INIS)

    Jadav, Hiralal; Joshi, Rameshkumar; Mali, Aniruddh K.; Kadia; Bhavesh; Parmar; Maganbhai, Kiritkumar; Kulkarni, S.V.

    2015-01-01

    This paper presents details of PLC based system development for 100KW at the rate 45.6 MHz. Presently in ICRH RF DAC (Data acquisition and control) system existing based on real time VME and linux operating system. The ICRH system consists of 1.5 MW RF generator operating at 22- 40MHz which is used for second harmonic heating and pre-ionization experiments on SST-1 Tokamak at 1.5T and 3T magnetic field operation respectively. The task of PLC system in RF ICRH is to control, monitoring and interlocks HVDC power supply signal. Voltage and current signal of 2 kW, 20 kW, tetrode for 100 kW RF tube electrode like Filament, Control grid, Plate, Screen grid, signal monitor and voltage set raised by PLC analog IO module. Acknowledgement of the HVDC supply Filament, Control grid, Plate, Screen grid power supply is monitor and interlocks by PLC Digital IO module to interlocks stop the RF pulse and off HV power supply. The RF pulse(shot) to trigger signal generator (5mw) RF power output feed to LPA then chain of 2 KW, 20 KW, 100 KW at the rate 45.6 MHz. The programming logic controller (PLC) software is written in ladder language for AH500 Delta make using ISP Soft 2.04 and GUI is in the table form to control and monitor the parameters. Communication of PLC to PC by ethernet LAN network. (author)

  16. USER S GUIDE FOR THE RANDOM DRUG SCREENING SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    McNeany, Karen I [ORNL

    2013-12-01

    The Random Drug Screening System (RDSS) is a desktop computing application designed to assign nongameable drug testing dates to each member in a population of employees, within a specific time line. The program includes reporting capabilities, test form generation, unique test ID number assignment, and the ability to flag high-risk employees for a higher frequency of drug testing than the general population.

  17. Digital systems to acquire radiological imaging. Characteristics and quality control; Sistemas digitales de adquisicion de imagenes radiograficas. Caracteristicas y Control de Calidad

    Energy Technology Data Exchange (ETDEWEB)

    Torres Cabrera, R.; Hernando Gonzalez, I.

    2006-07-01

    Due to its special characteristics, quality control in digital radiographic systems is very important, even more than in conventional film-screen systems. Differences between digital and analogical images,a in terms of dynamics range, spatial and contrast resolution, and the flexibility of data post-processing require some actions to maintain clinical images in an optimum quality level. Revision 1 of the Spanish Protocol of Quality Control in Diagnostic Radiology includes a chapter dedicated to the quality control of these digital systems for the acquisition of radiographic images. In this paper the different parameters for quality control procedures are described. Also some difficulties to be concerned about (absence of levels of tolerance, access to the raw-data images and related information, availability of use anthropomorphic phantoms, etc, etc) are noted, as well as the most significant aspects of the differences in relation to the ana logical systems. (Author) 15 refs.

  18. Implementation of Software Tools for Hybrid Control Rooms in the Human Systems Simulation Laboratory

    International Nuclear Information System (INIS)

    Jokstad, Håkon; Berntsson, Olof; McDonald, Robert; Boring, Ronald; Hallbert, Bruce; Fitzgerald, Kirk

    2014-01-01

    The Institute for Energy Technology (IFE) and Idaho National Laboratory have designed, implemented, tested and installed a functioning prototype of a set of large screen overview and procedure support displays for the Generic Pressurized Water Reactor (GPWR) simulator in the U.S. Department of Energy's Human Systems Simulation Laboratory. The overview display is based on IFE's extensive experiences with large screen overview displays in the Halden Man-Machine Laboratory (HAMMLAB), and presents the main control room indicators on a combined three-screen display. The procedure support displays are designed and implemented to provide a compact but still comprehensive overview of the relevant process measurements and indicators to support operators' good situational awareness during the performance of various types of procedures and plant conditions.

  19. Implementation of Software Tools for Hybrid Control Rooms in the Human Systems Simulation Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Jokstad, Håkon [Halden Reactor Project, Halden (Norway); Berntsson, Olof [Halden Reactor Project, Halden (Norway); McDonald, Robert [Halden Reactor Project, Halden (Norway); Boring, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hallbert, Bruce [Idaho National Lab. (INL), Idaho Falls, ID (United States); Fitzgerald, Kirk [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-11-01

    The Institute for Energy Technology (IFE) and Idaho National Laboratory have designed, implemented, tested and installed a functioning prototype of a set of large screen overview and procedure support displays for the Generic Pressurized Water Reactor (GPWR) simulator in the U.S. Department of Energy’s Human Systems Simulation Laboratory. The overview display is based on IFE’s extensive experiences with large screen overview displays in the Halden Man-Machine Laboratory (HAMMLAB), and presents the main control room indicators on a combined three-screen display. The procedure support displays are designed and implemented to provide a compact but still comprehensive overview of the relevant process measurements and indicators to support operators' good situational awareness during the performance of various types of procedures and plant conditions.

  20. Light-scattering properties of a woven shade-screen material used for daylighting and solar heat-gain control

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Jacob; Jonsson, Jacob C.; Lee, Eleanor S.; Rubin, Mike

    2008-08-01

    Shade-screens are widely used in commercial buildings as a way to limit the amount of direct sunlight that can disturb people in the building. The shade screens also reduce the solar heat-gain through glazing the system. Modern energy and daylighting analysis software such as EnergyPlus and Radiance require complete scattering properties of the scattering materials in the system. In this paper a shade screen used in the LBNL daylighting testbed is characterized using a photogoniometer and a normal angle of incidence integrating sphere. The data is used to create a complete bi-directional scattering distribution function (BSDF) that can be used in simulation programs. The resulting BSDF is compared to a model BADFs, both directly and by calculating the solar heat-gain coefficient for a dual pane system using Window 6.

  1. Advanced control system for the scattering chamber of K-130 cyclotron

    International Nuclear Information System (INIS)

    Bhaumik, Tapas Kumar; Saha, Amiya Kumar; Mandal, Bidhan Chandra; Adak, Debabrata; Purkait, Monirul; Bhattacharya, Sailajananda

    2013-01-01

    The old relay based position control system of the Scattering Chamber of K-130 Cyclotron was more than 30 years old, developed multiple problems over the years, and the components of the control system like relays, potentiometers, limit switches, radiation resistant cables were not functioning as per specifications. It has been replaced recently by a new PLC based embedded control system. This has been developed using Advantech ADAM-5510EKW 16 bit CPU together with required I/O modules. MULTIPROG Basic V.4.6 has been used as programming software and Ladder Diagram has been used to realize control scheme of the PLC. A resistive type touch screen based operator panel, WebOP-2104VN4AE has been mounted on the control rack for local control. iFIX SCADA, 75 tags Runtime Version 5.1 has been used to operate from remote PC connected to the PLC by 70m CAT6 cable. The PLC communicates with the touch panel and remote PC through 100 Mbps Ethernet switch. The Graphical User Interfaces of the local control panel and the remote panel have been developed as per the requirement from the users. All the old sensors, limit switches, relays and cables have been replaced by new items. This paper reports about the development and commissioning of basic hardware, software and operation of the control system for last six months. (author)

  2. Technical Requirements Analysis and Control Systems (TRACS) Initial Operating Capability (IOC) documentation

    Science.gov (United States)

    Hammond, Dana P.

    1991-01-01

    The Technical Requirements Analysis and Control Systems (TRACS) software package is described. TRACS offers supplemental tools for the analysis, control, and interchange of project requirements. This package provides the fundamental capability to analyze and control requirements, serves a focal point for project requirements, and integrates a system that supports efficient and consistent operations. TRACS uses relational data base technology (ORACLE) in a stand alone or in a distributed environment that can be used to coordinate the activities required to support a project through its entire life cycle. TRACS uses a set of keyword and mouse driven screens (HyperCard) which imposes adherence through a controlled user interface. The user interface provides an interactive capability to interrogate the data base and to display or print project requirement information. TRACS has a limited report capability, but can be extended with PostScript conventions.

  3. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  4. Screening of bacterial antagonists for biological control of Phytophthora blight of pepper.

    Science.gov (United States)

    Rajkumar, M; Lee, Wang Hyu; Lee, Kui Jae

    2005-01-01

    The aim of this study was to assess the potential of bacterial antagonists to control Phytophthora blight of pepper caused by P. capsici using different screening methods. Among a collection of fluorescent pseudomonas isolated from the rhizosphere of pepper, twelve isolates were initially selected based on dual culture assay on potato dextrose agar and corn meal agar. Further, these twelve isolates were screened for the reduction of disease severity caused by P. capsici using detached leaves and seedling assay. Most of the antagonists showed varying levels of antagonism against P. capsici in both detached leaves and seedlings assay. In addition, few isolates increased shoot and root length of pepper in seedling assays. Among them, isolate PS119 showing highest ability to reduce the disease severity in the in vitro seedling assay was found to be the most efficient antagonists against P. capsici in the in vivo biological control tests. These results indicate that the in vitro seedling assay can be used as a rapid and more accurate technique for the selection of promising biocontrol agents against P. capsici. ((c) 2005 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim).

  5. Operations and communications within the Daresbury Nuclear Structure Facility control system

    International Nuclear Information System (INIS)

    Davis, S.V.; Horrabin, C.W.; Johnstone, W.T.; Spurling, K.

    1984-01-01

    The Nuclear Structure Facility at Daresbury is a 20Mv Tandem Van de Graaff heavy ion accelerator. The design of the machine requires beam handling, vacuum, diagnostic and machine control equipment to be distributed within the accelerator in control sections maintained at different high potentials. All equipment also has to withstand huge electrical discharges. It is not possible to communicate directly with equipment across wires and although in previous machines a limited range of control functions have been carried out using electro-mechanical means the number of control and monitoring channels required on the NSF, the limited space, and the hostile environment led to the decision to design a distributed analogue and digital multiplexing system housed in special double screened enclosures. The outstation crates of this system are interconnected by a serial digital communications ring using a mixture of free space or fibre optic infra-red light links, or transformer coupled coaxial cable transmission as appropriate. Each area of the accelerator is served by one A/D multiplex ring of this type which carries the entire data for control and monitoring within that area. The system makes extensive use of micro processors which organize communications over these rings. One crate on each ring provides a port for the connection of a control system computer. The NSF control system is thus based on a computer compatible connection with the accelerator over which all information passes, whatever its purpose within the overall control strategy

  6. Implementation of digital control and protection systems of China advanced research reactor

    International Nuclear Information System (INIS)

    Zeng Hai; Jin Huajin; Xu Qiguo; Zhang Mingkui

    2005-01-01

    China Advanced Research Reactor (CARR), a reactor of the 21st century with high performance is being constructed in China. The requirements of reliability and stability on the control and protection (c and p) system are the main points raised. Especially, with the development of digital technology, the c and p system of CARR is demanded to match the trend of digitization in the field of reactor control. The c and p system, including reactor protection system, reactor monitoring and control system, reactor power regulating system, and the mitigation system for ATWS (Anticipate Transient Without Scram), adopts digital technology, and the digital display screen will replace the analog panels in the main control room. The c and p system of CARR adopts redundant technology with 2 or 3 redundant channels to improve the system reliability. The 10/100 Mbps self-adaptive redundant optic fiber industry Ethernet ring network is used to interlink operator workstations, supervisor workstation, and I/O control stations. Commercial grade equipment with mature experience in industrial application are applied to the c and p system of CARR, which have high reliability, good interchangeability, and is easily purchased, the software-developing tools fully match the international industry standards. The realization of digital c and p system of CARR will promote the progress of digital control technology for reactors in China, and certainly become a technical basic platform for developing informational and intelligent reactors in China. (authors)

  7. Cloud Screening and Quality Control Algorithm for Star Photometer Data: Assessment with Lidar Measurements and with All-sky Images

    Science.gov (United States)

    Ramirez, Daniel Perez; Lyamani, H.; Olmo, F. J.; Whiteman, D. N.; Navas-Guzman, F.; Alados-Arboledas, L.

    2012-01-01

    This paper presents the development and set up of a cloud screening and data quality control algorithm for a star photometer based on CCD camera as detector. These algorithms are necessary for passive remote sensing techniques to retrieve the columnar aerosol optical depth, delta Ae(lambda), and precipitable water vapor content, W, at nighttime. This cloud screening procedure consists of calculating moving averages of delta Ae() and W under different time-windows combined with a procedure for detecting outliers. Additionally, to avoid undesirable Ae(lambda) and W fluctuations caused by the atmospheric turbulence, the data are averaged on 30 min. The algorithm is applied to the star photometer deployed in the city of Granada (37.16 N, 3.60 W, 680 ma.s.l.; South-East of Spain) for the measurements acquired between March 2007 and September 2009. The algorithm is evaluated with correlative measurements registered by a lidar system and also with all-sky images obtained at the sunset and sunrise of the previous and following days. Promising results are obtained detecting cloud-affected data. Additionally, the cloud screening algorithm has been evaluated under different aerosol conditions including Saharan dust intrusion, biomass burning and pollution events.

  8. Microengineering methods for cell-based microarrays and high-throughput drug-screening applications

    International Nuclear Information System (INIS)

    Xu Feng; Wu Jinhui; Wang Shuqi; Gurkan, Umut Atakan; Demirci, Utkan; Durmus, Naside Gozde

    2011-01-01

    Screening for effective therapeutic agents from millions of drug candidates is costly, time consuming, and often faces concerns due to the extensive use of animals. To improve cost effectiveness, and to minimize animal testing in pharmaceutical research, in vitro monolayer cell microarrays with multiwell plate assays have been developed. Integration of cell microarrays with microfluidic systems has facilitated automated and controlled component loading, significantly reducing the consumption of the candidate compounds and the target cells. Even though these methods significantly increased the throughput compared to conventional in vitro testing systems and in vivo animal models, the cost associated with these platforms remains prohibitively high. Besides, there is a need for three-dimensional (3D) cell-based drug-screening models which can mimic the in vivo microenvironment and the functionality of the native tissues. Here, we present the state-of-the-art microengineering approaches that can be used to develop 3D cell-based drug-screening assays. We highlight the 3D in vitro cell culture systems with live cell-based arrays, microfluidic cell culture systems, and their application to high-throughput drug screening. We conclude that among the emerging microengineering approaches, bioprinting holds great potential to provide repeatable 3D cell-based constructs with high temporal, spatial control and versatility.

  9. Microengineering methods for cell-based microarrays and high-throughput drug-screening applications

    Energy Technology Data Exchange (ETDEWEB)

    Xu Feng; Wu Jinhui; Wang Shuqi; Gurkan, Umut Atakan; Demirci, Utkan [Department of Medicine, Demirci Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Center for Biomedical Engineering, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States); Durmus, Naside Gozde, E-mail: udemirci@rics.bwh.harvard.edu [School of Engineering and Division of Biology and Medicine, Brown University, Providence, RI (United States)

    2011-09-15

    Screening for effective therapeutic agents from millions of drug candidates is costly, time consuming, and often faces concerns due to the extensive use of animals. To improve cost effectiveness, and to minimize animal testing in pharmaceutical research, in vitro monolayer cell microarrays with multiwell plate assays have been developed. Integration of cell microarrays with microfluidic systems has facilitated automated and controlled component loading, significantly reducing the consumption of the candidate compounds and the target cells. Even though these methods significantly increased the throughput compared to conventional in vitro testing systems and in vivo animal models, the cost associated with these platforms remains prohibitively high. Besides, there is a need for three-dimensional (3D) cell-based drug-screening models which can mimic the in vivo microenvironment and the functionality of the native tissues. Here, we present the state-of-the-art microengineering approaches that can be used to develop 3D cell-based drug-screening assays. We highlight the 3D in vitro cell culture systems with live cell-based arrays, microfluidic cell culture systems, and their application to high-throughput drug screening. We conclude that among the emerging microengineering approaches, bioprinting holds great potential to provide repeatable 3D cell-based constructs with high temporal, spatial control and versatility.

  10. Screening and contact precautions – A survey on infection control measures for multidrug-resistant bacteria in German university hospitals

    Directory of Open Access Journals (Sweden)

    Lena M. Biehl

    2017-04-01

    Full Text Available Abstract To assess the scope of infection control measures for multidrug-resistant bacteria in high-risk settings, a survey among university hospitals was conducted. Fourteen professionals from 8 sites participated. Reported policies varied largely with respect to the types of wards conducting screening, sample types used for screening and implementation of contact precautions. This variability among sites highlights the need for an evidence-based consensus of current infection control policies.

  11. A comparison of image quality and dose requirements of a new conventional film-screen system for skeletal radiography

    International Nuclear Information System (INIS)

    Freitag, P.; Gueckel, C.; Fournier, P.J.; Roth, J.; Steinbrich, W.

    1995-01-01

    This paper compares a new film-screen system (FSS) called INSIGHT Skeletal Imaging System with the previously used Lanex/T-MAT G FSS. Using a Bronder phantom, measurements were made of dose, resolution and contrast. 135 skeletal phantom images were assessed in order of quality by six observers. Comparable high resolution film-screen combinations (FSC) showed similar geometric resolution. Comparing high intensifying screens, the new INSIGHT Skeletal Regular FSS showed better resolution than the Lanex medium FSC. Dose reduction for the INSIGHT Skeletal Imaging FSS was 29-56%. The new FSS showed image quality similar to high resolution screens but was significantly better when using high intensifying screens. (orig./MG) [de

  12. Mobile Phone Multilevel and Multimedia Messaging Intervention for Breast Cancer Screening: Pilot Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Hee; Ghebre, Rahel; Le, Chap; Jang, Yoo Jeong; Sharratt, Monica; Yee, Douglas

    2017-11-07

    Despite the increasing breast cancer incidence and mortality rates, Korean American immigrant women have one of the lowest rates of breast cancer screening across racial groups in the United States. Mobile health (mHealth), defined as the delivery of health care information or services through mobile communication devices, has been utilized to successfully improve a variety of health outcomes. This study adapted the principles of mHealth to advance breast cancer prevention efforts among Korean American immigrant women, an underserved community. Using a randomized controlled trial design, 120 Korean American women aged 40 to 77 years were recruited and randomly assigned to either the mMammogram intervention group (n=60) to receive culturally and personally tailored multilevel and multimedia messages through a mobile phone app along with health navigator services or the usual care control group (n=60) to receive a printed brochure. Outcome measures included knowledge, attitudes, and beliefs about breast cancer screening, readiness for mammography, and mammogram receipt. The feasibility and acceptability of the mMammogram intervention was also assessed. The intervention group showed significantly greater change on scores of knowledge of breast cancer and screening guidelines (P=.01). The intervention group also showed significantly greater readiness for mammography use after the intervention compared with the control group. A significantly higher proportion of women who received the mMammogram intervention (75%, 45/60) completed mammograms by the 6-month follow-up compared with the control group (30%, 18/60; Pservice was a feasible, acceptable, and effective intervention mechanism to promote breast cancer screening in Korean American immigrant women. A flexible, easily tailored approach that relies on recent technological advancements can reach underserved and hard-to-recruit populations that bear disproportionate cancer burdens. Clinicaltrials.gov NCT01972048;

  13. A rapid in vitro screening system for the identification and evaluation of anticancer drugs

    International Nuclear Information System (INIS)

    Kao, J.W.; Collins, J.L.

    1989-01-01

    We report the development of an in vitro screening system that can be used to identify new anticancer drugs that are specifically cytotoxic for dividing cells. The screening system takes advantage of the potential of many cell lines, including tumor cells, to stop dividing when they are plated at high cell density. The cytotoxic effects of anticancer drugs on dividing (i.e., cells plated at low cell density) and nondividing cells (i.e., cells plated at high cell density) is measured by the incorporation of 51Cr. This in vitro system was evaluated by measuring the cytotoxic effects of the anticancer drugs cisplatin, thiotepa, doxorubicin, methotrexate, and vinblastine on the cell lines B/C-N, ME-180, and MCF-7. In this in vitro system the concentrations of the anticancer drugs that produced significant cytotoxicity on only dividing cells are similar to the concentrations that are used clinically. The fact that this in vitro system is rapid, simple, applicable to many cell types, and able to predict effective concentrations of anticancer drugs should make it useful for the screening of new anticancer drugs and for the design of preclinical studies

  14. A Prototype Lisp-Based Soft Real-Time Object-Oriented Graphical User Interface for Control System Development

    Science.gov (United States)

    Litt, Jonathan; Wong, Edmond; Simon, Donald L.

    1994-01-01

    A prototype Lisp-based soft real-time object-oriented Graphical User Interface for control system development is presented. The Graphical User Interface executes alongside a test system in laboratory conditions to permit observation of the closed loop operation through animation, graphics, and text. Since it must perform interactive graphics while updating the screen in real time, techniques are discussed which allow quick, efficient data processing and animation. Examples from an implementation are included to demonstrate some typical functionalities which allow the user to follow the control system's operation.

  15. An object-oriented implementation of the TRIUMF 92 MHz booster cavity control system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Ludgate, G.A.

    1992-01-01

    A 92 MHz auxiliary accelerating cavity has been designed for installation inside the TRIUMF cyclotron, operating up to a maximum peak voltage of 200 kV. The cavity doubles the energy gain per turn for accelerating hydrogen ions in the energy region of 400-500 MeV, and reduces by 50% the stripping loss of the ion beam. The control system for the booster comprises a PC-based processor in a VME crate, for local control, and a 68030 processor with an ethernet connection as the interface to the TRIUMF Central Control System. The requirements for the booster control system were established by an object-oriented requirements analysis. Afterward, an object-oriented architectural design step was used to produce the processor allocation of the design, which was then implemented using C, for the VME processor, and a commercial database and screen generator product, for the VAX user interface. (author)

  16. Randomized controlled trial of storytelling compared to a personal risk tool intervention on colorectal cancer screening in low-income patients.

    Science.gov (United States)

    Larkey, Linda K; McClain, Darya; Roe, Denise J; Hector, Richard D; Lopez, Ana Maria; Sillanpaa, Brian; Gonzalez, Julie

    2015-01-01

    Screening rates for colorectal cancer (CRC) lag for low-income, minority populations, contributing to poorer survival rates. A model of storytelling as culture-centric health promotion was tested for promoting CRC screening. A two-group parallel randomized controlled trial. Primary care, safety-net clinics. Low-income patients due for CRC screening, ages 50 to 75 years, speaking English or Spanish. Patients were exposed to either a video created from personal stories composited into a drama about "Papa" receiving CRC screening, or an instrument estimating level of personal cancer risk. Patients received a health care provider referral for CRC screening and were followed up for 3 months to document adherence. Behavioral factors related to the narrative model (identification and engagement) and theory of planned behavior. Main effects of the interventions on screening were tested, controlling for attrition factors, and demographic factor associations were assessed. Path analysis with model variables was used to test the direct effects and multiple mediator models. Main effects on CRC screening (roughly half stool-based tests, half colonoscopy) did not indicate significant differences (37% and 42% screened for storytelling and risk-based messages, respectively; n = 539; 33.6% male; 62% Hispanic). Factors positively associated with CRC screening included being female, Hispanic, married or living with a partner, speaking Spanish, having a primary care provider, lower income, and no health insurance. Engagement, working through positive attitudes toward the behavior, predicted CRC screening. A storytelling and a personalized risk-tool intervention achieved similar levels of screening among unscreened/underscreened, low-income patients. Factors usually associated with lower rates of screening (e.g., no insurance, being Hispanic) were related to more adherence. Both interventions' engagement factor facilitated positive attitudes about CRC screening associated with behavior

  17. The UK Lung Cancer Screening Trial: a pilot randomised controlled trial of low-dose computed tomography screening for the early detection of lung cancer.

    Science.gov (United States)

    Field, John K; Duffy, Stephen W; Baldwin, David R; Brain, Kate E; Devaraj, Anand; Eisen, Tim; Green, Beverley A; Holemans, John A; Kavanagh, Terry; Kerr, Keith M; Ledson, Martin; Lifford, Kate J; McRonald, Fiona E; Nair, Arjun; Page, Richard D; Parmar, Mahesh Kb; Rintoul, Robert C; Screaton, Nicholas; Wald, Nicholas J; Weller, David; Whynes, David K; Williamson, Paula R; Yadegarfar, Ghasem; Hansell, David M

    2016-05-01

    Lung cancer kills more people than any other cancer in the UK (5-year survival high-risk UK population, determine optimum recruitment, screening, reading and care pathway strategies; and (2) assess the psychological consequences and the health-economic implications of screening. A pilot randomised controlled trial comparing intervention with usual care. A population-based risk questionnaire identified individuals who were at high risk of developing lung cancer (≥ 5% over 5 years). Thoracic centres with expertise in lung cancer imaging, respiratory medicine, pathology and surgery: Liverpool Heart & Chest Hospital, Merseyside, and Papworth Hospital, Cambridgeshire. Individuals aged 50-75 years, at high risk of lung cancer, in the primary care trusts adjacent to the centres. A thoracic LDCT scan. Follow-up computed tomography (CT) scans as per protocol. Referral to multidisciplinary team clinics was determined by nodule size criteria. Population-based recruitment based on risk stratification; management of the trial through web-based database; optimal characteristics of CT scan readers (radiologists vs. radiographers); characterisation of CT-detected nodules utilising volumetric analysis; prevalence of lung cancer at baseline; sociodemographic factors affecting participation; psychosocial measures (cancer distress, anxiety, depression, decision satisfaction); and cost-effectiveness modelling. A total of 247,354 individuals were approached to take part in the trial; 30.7% responded positively to the screening invitation. Recruitment of participants resulted in 2028 in the CT arm and 2027 in the control arm. A total of 1994 participants underwent CT scanning: 42 participants (2.1%) were diagnosed with lung cancer; 36 out of 42 (85.7%) of the screen-detected cancers were identified as stage 1 or 2, and 35 (83.3%) underwent surgical resection as their primary treatment. Lung cancer was more common in the lowest socioeconomic group. Short-term adverse psychosocial

  18. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Science.gov (United States)

    2010-04-01

    ..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  19. Screen dealing

    International Nuclear Information System (INIS)

    Barlow, J.W.

    1991-01-01

    The screen dealing system provides a facility whereby buyers and sellers of spot thermal coal can make bids and offers via the medium of the Reuters screen. A sale results when a market participant notifies his acceptance of a price to a central dealing desk. Use of the system is available to all genuine participants in the coal trade. This paper reports that it provides a focus for information and for the visible making of coal prices. For years screen trading has been used successfully to trade other commodities. At last coal is being traded electronically. It makes sense. It works. Users like it

  20. An hourly based performance comparison of an integrated micro-structural perforated shading screen with standard shading systems

    DEFF Research Database (Denmark)

    Appelfeld, David; McNeil, Andrew; Svendsen, Svend

    2012-01-01

    This article evaluates the performance of an integrated micro structural perforated shading screen (MSPSS). Such a system maintains a visual connection with the outdoors while imitating the shading functionality of a venetian blind. Building energy consumption is strongly influenced by the solar...... gains and heat transfer through the transparent parts of the fenestration systems. MSPSS is angular-dependent shading device that provides an effective strategy in the control of daylight, solar gains and overheating through windows. The study focuses on using direct experimental methods to determine bi......-directional transmittance properties of shading systems that are not included as standard shading options in readily available building performance simulation tools. The impact on the indoor environment, particularly temperature and daylight were investigated and compared to three other static complex fenestration systems...

  1. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  2. Opportunistic mammography screening provides effective detection rates in a limited resource healthcare system.

    Science.gov (United States)

    Teh, Yew-Ching; Tan, Gie-Hooi; Taib, Nur Aishah; Rahmat, Kartini; Westerhout, Caroline Judy; Fadzli, Farhana; See, Mee-Hoong; Jamaris, Suniza; Yip, Cheng-Har

    2015-05-15

    Breast cancer is the leading cause of cancer deaths in women world-wide. In low and middle income countries, where there are no population-based mammographic screening programmes, late presentation is common, and because of inadequate access to optimal treatment, survival rates are poor. Mammographic screening is well-studied in high-income countries in western populations, and because it has been shown to reduce breast cancer mortality, it has become part of the healthcare systems in such countries. However the performance of mammographic screening in a developing country is largely unknown. This study aims to evaluate the performance of mammographic screening in Malaysia, a middle income country, and to compare the stage and surgical treatment of screen-detected and symptomatic breast cancer. A retrospective review of 2510 mammograms performed from Jan to Dec 2010 in a tertiary medical centre is carried out. The three groups identified are the routine (opportunistic) screening group, the targeted (high risk) screening group and the diagnostic group. The performance indicators of each group is calculated, and stage at presentation and treatment between the screening and diagnostic group is analyzed. The cancer detection rate in the opportunistic screening group, targeted screening group, and the symptomatic group is 0.5 %, 1.25 % and 26 % respectively. The proportion of ductal carcinoma in situ is 23.1 % in the two screening groups compared to only 2.5 % in the diagnostic group. Among the opportunistic screening group, the cancer detection rate was 0.2 % in women below 50 years old compared to 0.65 % in women 50 years and above. The performance indicators are within international standards. Early-staged breast cancer (Stage 0-2) were 84.6 % in the screening groups compared to 61.1 % in the diagnostic group. From the results, in a setting with resource constraints, targeted screening of high risk individuals will give a higher yield, and if more resources are

  3. Recent improvements to the DIII-D neutral beam instrumentation and control system

    International Nuclear Information System (INIS)

    Kellman, D.H.; Hong, R.

    1997-11-01

    The DIII-D neutral beam (NB) instrumentation and control (I and C) system provides for operational control and synchronization of the eight DIII-D neutral beam injection systems, as well as for pertinent data acquisition and safety interlocking. Recently, improvements were made to the I and C system. With the replacement of the NB control computers, new signal interfacing was required to accommodate the elimination of physical operator panels, in favor of graphical user interface control pages on computer terminal screens. The program in the mode control (MC) programmable logic controller (PLC), which serves as a logic-processing interface between the NB control computers and system hardware, was modified to improve the availability of NB heating of DIII-D plasmas in the event that one or more individual beam systems suddenly become unavailable while preparing for a tokamak experimental shot sequences. An upgraded computer platform was adopted for the NB control system operator interface and new graphical user interface pages were developed to more efficiently display system status data. A failure mode of the armor tile infrared thermometers (pyrometers), which serve to terminate beam pulsing if beam shine-through overheats wall thermal shielding inside the DIII-D tokamak, was characterized such that impending failures can be detected and repairs effected to mitigate beam system down-time. The hardware that controls gas flow to the beamline neutralizer cells was upgraded to reduce susceptibility to electromagnetic interference (EMI), and interlocking was provided to terminate beam pulsing in the event of insufficient neutralizer gas flow. Motivation, implementation, and results of these improvements are presented

  4. Primary care colorectal cancer screening correlates with breast cancer screening: implications for colorectal cancer screening improvement interventions.

    Science.gov (United States)

    Weiss, Jennifer M; Pandhi, Nancy; Kraft, Sally; Potvien, Aaron; Carayon, Pascale; Smith, Maureen A

    2018-04-25

    National colorectal cancer (CRC) screening rates have plateaued. To optimize interventions targeting those unscreened, a better understanding is needed of how this preventive service fits in with multiple preventive and chronic care needs managed by primary care providers (PCPs). This study examines whether PCP practices of other preventive and chronic care needs correlate with CRC screening. We performed a retrospective cohort study of 90 PCPs and 33,137 CRC screening-eligible patients. Five PCP quality metrics (breast cancer screening, cervical cancer screening, HgbA1c and LDL testing, and blood pressure control) were measured. A baseline correlation test was performed between these metrics and PCP CRC screening rates. Multivariable logistic regression with clustering at the clinic-level estimated odds ratios and 95% confidence intervals for these PCP quality metrics, patient and PCP characteristics, and their relationship to CRC screening. PCP CRC screening rates have a strong correlation with breast cancer screening rates (r = 0.7414, p < 0.001) and a weak correlation with the other quality metrics. In the final adjusted model, the only PCP quality metric that significantly predicted CRC screening was breast cancer screening (OR 1.25; 95% CI 1.11-1.42; p < 0.001). PCP CRC screening rates are highly concordant with breast cancer screening. CRC screening is weakly concordant with cervical cancer screening and chronic disease management metrics. Efforts targeting PCPs to increase CRC screening rates could be bundled with breast cancer screening improvement interventions to increase their impact and success.

  5. In-bead screening

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to screening of one-bead-one-compound (OBOC) combinatorial libraries which is useful for the discovery of compounds displaying molecular interactions with a biological or a physicochemical system, such as substrates and inhibitors of enzymes and the like. The invention...... provides a method for screening a library of compounds for their interaction with a physico- chemical or biological system and a corresponding kit for performing the method of screening a one-bead-one-compound library of compounds....

  6. Acquisition system environmental effects study. [for capillary-screen propellant retention devices

    Science.gov (United States)

    1975-01-01

    The effects of vibration, warm gas exposure, and feed system startup/shutdown fluid dynamics on capillary-screen propellant retention capabilities are quantified. The existing technology is extended to the point where quantitative conlusions in terms of design criteria may be drawn.

  7. Computerised decision support systems in order communication for diagnostic, screening or monitoring test ordering: systematic reviews of the effects and cost-effectiveness of systems.

    Science.gov (United States)

    Main, C; Moxham, T; Wyatt, J C; Kay, J; Anderson, R; Stein, K

    2010-10-01

    Order communication systems (OCS) are computer applications used to enter diagnostic and therapeutic patient care orders and to view test results. Many potential benefits of OCS have been identified including improvements in clinician ordering patterns, optimisation of clinical time, and aiding communication processes between clinicians and different departments. Many OCS now include computerised decision support systems (CDSS), which are information systems designed to improve clinical decision-making. CDSS match individual patient characteristics to a computerised knowledge base, and software algorithms generate patient-specific recommendations. To investigate which CDSS in OCS are in use within the UK and the impact of CDSS in OCS for diagnostic, screening or monitoring test ordering compared to OCS without CDSS. To determine what features of CDSS are associated with clinician or patient acceptance of CDSS in OCS and what is known about the cost-effectiveness of CDSS in diagnostic, screening or monitoring test OCS compared to OCS without CDSS. A generic search to identify potentially relevant studies for inclusion was conducted using MEDLINE, EMBASE, Cochrane Controlled Trials Register (CCTR), CINAHL (Cumulative Index to Nursing and Allied Health Literature), DARE (Database of Abstracts of Reviews of Effects), Health Technology Assessment (HTA) database, IEEE (Institute of Electrical and Electronic Engineers) Xplore digital library, NHS Economic Evaluation Database (NHS EED) and EconLit, searched between 1974 and 2009 with a total of 22,109 titles and abstracts screened for inclusion. CDSS for diagnostic, screening and monitoring test ordering OCS in use in the UK were identified through contact with the 24 manufacturers/suppliers currently contracted by the National Project for Information Technology (NpfIT) to provide either national or specialist decision support. A generic search to identify potentially relevant studies for inclusion in the review was

  8. Modernization of control system using the digital control system

    International Nuclear Information System (INIS)

    Carrasco, J. A.; Fernandez, L.; Jimenez, A.

    2002-01-01

    Nowadays, all plant automation tendencies are based on the use of Digital Control System. In big industrial plants the control systems employed are Distributed Control Systems (DCS). The addition of these systems in nuclear power plants,implies an important adaptation process, because most of them were installed using analog control systems. This paper presents the objectives and the first results obtained, in a modernization project, focused in obtaining an engineering platform for making test and analysis of changes prior to their implementation in a nuclear plant. Modernization, Upgrade, DCS, Automation, Simulation, Training. (Author)

  9. Hepatitis C screening trends in a large integrated health system.

    Science.gov (United States)

    Linas, Benjamin P; Hu, Haihong; Barter, Devra M; Horberg, Michael

    2014-05-01

    As new hepatitis C virus (HCV) therapies emerge, only 1%-12% of individuals are screened in the US for HCV infection. Presently, HCV screening trends are unknown. We utilized the Kaiser Permanente Mid-Atlantic States' (KPMAS) data repository to investigate HCV antibody screening between January 1, 2003 and December 31, 2012. We identified the proportion screened for HCV and 5-year cumulative incidence of screening, the screening positivity rate, the provider types performing HCV screening, patient-level factors associated with being screened, and trends in screening over time. There were 444,594 patients who met the inclusion criteria. Overall, 15.8% of the cohort was ever screened for HCV. Adult primary care and obstetrics and gynecology providers performed 75.9% of all screening. The overall test positivity rate was 3.8%. Screening was more frequent in younger age groups (P <.0001) and those with a documented history of illicit drug use (P <.0001). Patients with missing drug use history (46.7%) were least likely to be screened (P <.0001). While the rate of HCV screening increased in the later years of the study among those enrolled in KPMAS 2009-2012, only 11.8% were screened by the end of follow-up. Screening for HCV is increasing but remains incomplete. Targeting screening to those with a history of injection drug will not likely expand screening, as nearly half of patients have no documented drug use history. Routine screening is likely the most effective approach to expand HCV screening. Copyright © 2014. Published by Elsevier Inc.

  10. Performance of a brief asthma control screening tool in community pharmacy: a cross-sectional and prospective longitudinal analysis.

    Science.gov (United States)

    LeMay, Kate S; Armour, Carol L; Reddel, Helen K

    2014-03-01

    Guidelines recommend basing asthma management on assessment of asthma control. Validated control tools, while suitable for clinical research, may not be feasible for routine use in primary care. To describe the performance of the Pharmacy Asthma Control Screening tool (PACS) compared with the Asthma Control Questionnaire (ACQ-6). Data were obtained from a multicentre study of a community pharmacy asthma management programme in Australia, with three or four visits over six months. Eligible participants had suboptimal asthma control or no recent visit to their doctor for asthma. Asthma control was assessed at baseline and at six months with the PACS tool and ACQ-6. A total of 570 patients were enrolled and 398 (70%) completed the programme. The average ACQ-6 score was 1.58±1.05 at baseline and 0.96±0.88 (n=392) after six months. Sensitivity and specificity of PACS 'poor control' for not well-controlled asthma (ACQ- 6 >1.0) were 0.92 and 0.66, respectively, at baseline and 0.76 and 0.83 at six months. Agreement between the two tools at six months was moderate (κ=0.54). Both tools showed highly significant change during the study (p<0.0001 for each), but agreement between the change in the two tools was only fair (κ=0.31). This study shows that a simple asthma control screening tool is feasible for use in community pharmacies and has good sensitivity for identifying patients with not well-controlled asthma. Screening tools are useful in primary care to identify patients who require more detailed assessment of their asthma status, whereas for monitoring asthma control over time, a continuous control measure is more appropriate.

  11. A Metric and Workflow for Quality Control in the Analysis of Heterogeneity in Phenotypic Profiles and Screens

    Science.gov (United States)

    Gough, Albert; Shun, Tongying; Taylor, D. Lansing; Schurdak, Mark

    2016-01-01

    Heterogeneity is well recognized as a common property of cellular systems that impacts biomedical research and the development of therapeutics and diagnostics. Several studies have shown that analysis of heterogeneity: gives insight into mechanisms of action of perturbagens; can be used to predict optimal combination therapies; and to quantify heterogeneity in tumors where heterogeneity is believed to be associated with adaptation and resistance. Cytometry methods including high content screening (HCS), high throughput microscopy, flow cytometry, mass spec imaging and digital pathology capture cell level data for populations of cells. However it is often assumed that the population response is normally distributed and therefore that the average adequately describes the results. A deeper understanding of the results of the measurements and more effective comparison of perturbagen effects requires analysis that takes into account the distribution of the measurements, i.e. the heterogeneity. However, the reproducibility of heterogeneous data collected on different days, and in different plates/slides has not previously been evaluated. Here we show that conventional assay quality metrics alone are not adequate for quality control of the heterogeneity in the data. To address this need, we demonstrate the use of the Kolmogorov-Smirnov statistic as a metric for monitoring the reproducibility of heterogeneity in an SAR screen, describe a workflow for quality control in heterogeneity analysis. One major challenge in high throughput biology is the evaluation and interpretation of heterogeneity in thousands of samples, such as compounds in a cell-based screen. In this study we also demonstrate that three heterogeneity indices previously reported, capture the shapes of the distributions and provide a means to filter and browse big data sets of cellular distributions in order to compare and identify distributions of interest. These metrics and methods are presented as a

  12. Women with learning disabilities and access to cervical screening: retrospective cohort study using case control methods

    Science.gov (United States)

    Reynolds, Fiona; Stanistreet, Debbi; Elton, Peter

    2008-01-01

    Background Several studies in the UK have suggested that women with learning disabilities may be less likely to receive cervical screening tests and a previous local study in had found that GPs considered screening unnecessary for women with learning disabilities. This study set out to ascertain whether women with learning disabilities are more likely to be ceased from a cervical screening programme than women without; and to examine the reasons given for ceasing women with learning disabilities. It was carried out in Bury, Heywood-and-Middleton and Rochdale. Methods Carried out using retrospective cohort study methods, women with learning disabilities were identified by Read code; and their cervical screening records were compared with the Call-and-Recall records of women without learning disabilities in order to examine their screening histories. Analysis was carried out using case-control methods – 1:2 (women with learning disabilities: women without learning disabilities), calculating odds ratios. Results 267 women's records were compared with the records of 534 women without learning disabilities. Women with learning disabilities had an odds ratio (OR) of 0.48 (Confidence Interval (CI) 0.38 – 0.58; X2: 72.227; p.value learning disabilities. Conclusion The reasons given for ceasing and/or not screening suggest that merely being coded as having a learning disability is not the sole reason for these actions. There are training needs among smear takers regarding appropriate reasons not to screen and providing screening for women with learning disabilities. PMID:18218106

  13. A Genome-wide multidimensional RNAi screen reveals pathways controlling MHC class II antigen presentation

    NARCIS (Netherlands)

    Paul, Petra; van den Hoorn, Tineke; Jongsma, Marlieke L. M.; Bakker, Mark J.; Hengeveld, Rutger; Janssen, Lennert; Cresswell, Peter; Egan, David A.; van Ham, Marieke; ten Brinke, Anja; Ovaa, Huib; Beijersbergen, Roderick L.; Kuijl, Coenraad; Neefjes, Jacques

    2011-01-01

    MHC class II molecules (MHC-II) present peptides to T helper cells to facilitate immune responses and are strongly linked to autoimmune diseases. To unravel processes controlling MHC-II antigen presentation, we performed a genome-wide flow cytometry-based RNAi screen detecting MHC-II expression and

  14. Estimation of effectiveness of interventions for malaria control in pregnancy using the screening method

    NARCIS (Netherlands)

    Msyamboza, K.; Senga, E.; Tetteh-Ashong, E.; Kazembe, P.; Brabin, B. J.

    2007-01-01

    BACKGROUND: The evaluation of the effectiveness of antimalarial drugs and bed net use in pregnant women is an important aspect of monitoring and surveillance of malaria control in pregnancy. In principle the screening method for assessing vaccine efficacy can be applied in non-vaccine settings for

  15. Comparative reading support system for lung cancer CT screening

    International Nuclear Information System (INIS)

    Kubo, Mitsuru; Saita, Shinsuke; Kawata, Yoshiki; Niki, Noboru; Suzuki, Hidenobu; Ohmatsu, Hironobu; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki

    2010-01-01

    The comparative reading is performed using current and past images of the same case obtained from lung cancer CT screening. The result of this is useful for the early detection of lung cancer. Our paper describes the efficiency improvement of comparative reading using 10 mm slice thickness CT images by developing the system consists of slice registration method, pulmonary nodule registration method, and quantitative evaluation method of pulmonary nodule's degree of change. The proposed system is applied to CT images scanned for 1107 times of 85 cases with 198 pulmonary nodules and is evaluated by comparing it with the reading result of the doctors. We show the effectiveness of the system. (author)

  16. Screening key parameters related to passive system performance based on Analytic Hierarchy Process

    International Nuclear Information System (INIS)

    Ma, Guohang; Yu, Yu; Huang, Xiong; Peng, Yuan; Ma, Nan; Shan, Zuhua; Niu, Fenglei; Wang, Shengfei

    2015-01-01

    Highlights: • An improved AHP method is presented for screening key parameters used in passive system reliability analysis. • We take the special bottom parameters as criterion for calculation and the abrupt change of the results are verified. • Combination weights are also affected by uncertainty of input parameters. - Abstract: Passive safety system is widely used in the new generation nuclear power plant (NPP) designs such as AP1000 to improve the reactor safety benefitting from its simple construction and less request for human intervene. However, the functional failure induced by uncertainty in the system thermal–hydraulic (T–H) performance becomes one of the main contributors to system operational failure since the system operates based on natural circulation, which should be considered in the system reliability evaluation. In order to improve the calculation efficiency the key parameters which significantly affect the system T–H characteristics can be screened and then be analyzed in detail. The Analytical Hierarchy Process (AHP) is one of the efficient methods to analyze the influence of the parameters on a passive system based on the experts’ experience. The passive containment cooling system (PCCS) in AP1000 is one of the typical passive safety systems, nevertheless too many parameters need to be analyzed and the T–H model itself is more complicated, so the traditional AHP method should be mended to use for screening key parameters efficiently. In this paper, we adapt the improved method in hierarchy construction and experts’ opinions integration, some parameters at the bottom justly in the traditional hierarchy are studied as criterion layer in improved AHP, the rationality of the method and the effect of abrupt change with the data are verified. The passive containment cooling system (PCCS) in AP1000 is evaluated as an example, and four key parameters are selected from 49 inputs

  17. MOLA: a bootable, self-configuring system for virtual screening using AutoDock4/Vina on computer clusters

    Directory of Open Access Journals (Sweden)

    Abreu Rui MV

    2010-10-01

    Full Text Available Abstract Background Virtual screening of small molecules using molecular docking has become an important tool in drug discovery. However, large scale virtual screening is time demanding and usually requires dedicated computer clusters. There are a number of software tools that perform virtual screening using AutoDock4 but they require access to dedicated Linux computer clusters. Also no software is available for performing virtual screening with Vina using computer clusters. In this paper we present MOLA, an easy-to-use graphical user interface tool that automates parallel virtual screening using AutoDock4 and/or Vina in bootable non-dedicated computer clusters. Implementation MOLA automates several tasks including: ligand preparation, parallel AutoDock4/Vina jobs distribution and result analysis. When the virtual screening project finishes, an open-office spreadsheet file opens with the ligands ranked by binding energy and distance to the active site. All results files can automatically be recorded on an USB-flash drive or on the hard-disk drive using VirtualBox. MOLA works inside a customized Live CD GNU/Linux operating system, developed by us, that bypass the original operating system installed on the computers used in the cluster. This operating system boots from a CD on the master node and then clusters other computers as slave nodes via ethernet connections. Conclusion MOLA is an ideal virtual screening tool for non-experienced users, with a limited number of multi-platform heterogeneous computers available and no access to dedicated Linux computer clusters. When a virtual screening project finishes, the computers can just be restarted to their original operating system. The originality of MOLA lies on the fact that, any platform-independent computer available can he added to the cluster, without ever using the computer hard-disk drive and without interfering with the installed operating system. With a cluster of 10 processors, and a

  18. A screening system for smear-negative pulmonary tuberculosis using artificial neural networks

    Directory of Open Access Journals (Sweden)

    João B. de O. Souza Filho

    2016-08-01

    Conclusions: In settings with a high prevalence of smear-negative PTB, the system can be useful for screening and also to aid clinical practice in expediting complementary tests for higher risk patients.

  19. Low cost automated whole smear microscopy screening system for detection of acid fast bacilli.

    Directory of Open Access Journals (Sweden)

    Yan Nei Law

    Full Text Available In countries with high tuberculosis (TB burden, there is urgent need for rapid, large-scale screening to detect smear-positive patients. We developed a computer-aided whole smear screening system that focuses in real-time, captures images and provides diagnostic grading, for both bright-field and fluorescence microscopy for detection of acid-fast-bacilli (AFB from respiratory specimens.To evaluate the performance of dual-mode screening system in AFB diagnostic algorithms on concentrated smears with auramine O (AO staining, as well as direct smears with AO and Ziehl-Neelsen (ZN staining, using mycobacterial culture results as gold standard.Adult patient sputum samples requesting for M. tuberculosis cultures were divided into three batches for staining: direct AO-stained, direct ZN-stained and concentrated smears AO-stained. All slides were graded by an experienced microscopist, in parallel with the automated whole smear screening system. Sensitivity and specificity of a TB diagnostic algorithm in using the screening system alone, and in combination with a microscopist, were evaluated.Of 488 direct AO-stained smears, 228 were culture positive. These yielded a sensitivity of 81.6% and specificity of 74.2%. Of 334 direct smears with ZN staining, 142 were culture positive, which gave a sensitivity of 70.4% and specificity of 76.6%. Of 505 concentrated smears with AO staining, 250 were culture positive, giving a sensitivity of 86.4% and specificity of 71.0%. To further improve performance, machine grading was confirmed by manual smear grading when the number of AFBs detected fell within an uncertainty range. These combined results gave significant improvement in specificity (AO-direct:85.4%; ZN-direct:85.4%; AO-concentrated:92.5% and slight improvement in sensitivity while requiring only limited manual workload.Our system achieved high sensitivity without substantially compromising specificity when compared to culture results. Significant improvement

  20. Design and evaluation of new overview screens for the LABIHS simulator

    International Nuclear Information System (INIS)

    Oliveira, Mauro V.; Almeida, Jose C.S.; Jaime, Guilherme D.G.; Augusto, Silas C.

    2015-01-01

    The development and evaluation of Human-System Interfaces (HSIs) for control rooms is a research area at the Human-System Interface Laboratory (LABIHS). The main objective of this laboratory is to develop and evaluate projects of HSIs for industrial plants using different methodology construction. The evaluation of the interfaces is carried out in the LABIHS simulator at the Nuclear Engineering Institute (IEN). Previous evaluation of the overview screen of the nuclear power plant (NPP) simulator of the LABIHS showed the necessity of additional information to reduce the operator workload. To overcome this issue, a set of three 52-inch LCD TV was acquired to replace the projector in the task of showing the overview screen to the simulator operators. A new set of screens was developed to gather information in the three LCD screens. The approach used on the development of the new screens was based on human factors guidelines and recommendations. The objective of this work is present the design of these new overview screens and to evaluate their contribution to reduce the operators mental workload in this new scenario. (author)

  1. Providing floating capabilities in latest-generation sand screens

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, E.G.; Coronado, M.P. [Society of Petroleum Engineers, Richardson, TX (United States)]|[Baker Hughes, Houston, TX (United States)

    2008-10-15

    Alternative production methods are needed for the massive reserves located in the bitumen region of Canada's tar sands. The area has over 100 installations of sand screens/slotted liners in both injection and production legs using steam-assisted gravity drainage (SAGD) technology. Multiple wells must be drilled from a single pad because of the sensitive nature of the environment. With significant depths of these wells, a floating sand screen provides assurance that the sand screen will reach the desired depth. Paraffin is generally used to plug the flow access of the screen during installation. This paper discussed a new technology that has been developed to allow for sand screen installations without relying on paraffin wax to withstand differential pressure. The new technology uses a hydro-mechanical valving system incorporated into the screen design to temporarily close off the screen while being run in the hole. The paper described how the technology could provide a reliable, time-saving solution for SAGD installations when floating sand control screens are needed. The paper discussed current technology and its limitations, sand screen installation, screen design for floating applications, and additional applications. It was concluded that this technology solution provides a unique alternative to the methods currently used to install sand screens with SAGD technology in the fast growing Canadian market for bitumen recovery. 2 refs., 5 figs.

  2. Screening detected celiac disease in children with type 1 diabetes mellitus : Effect on the clinical course - (A case control study)

    NARCIS (Netherlands)

    Rami, B; Sumnik, Z; Schober, E; Waldhor, T; Battelino, T; Bratanic, N; Kurti, K; Lebl, J; Limbert, C; Madacsy, L; Odink, RJH; Paskova, M; Soltesz, G

    Objective: To investigate clinical and metabolic characteristics of diabetic children with screening detected celiac disease in a multicenter case-control study. Methods: Cases: 98 diabetic patients were diagnosed as having silent celiac disease by screening with endomysial antibodies and subsequent

  3. Human-system interface evaluation system for advanced control room based on SQL database

    International Nuclear Information System (INIS)

    Zhang Yan; Zhou Zhiwei; Bian Zhiqiang; Xu Li

    2005-01-01

    User Interface (UI) plays an important role in the advanced control room (ACR) of a nuclear power plant (NPP). In this paper, we present a rule-based ACR Human-system Interface Evaluation System (AHSIES) using expert system technology, which can evaluate UI design shortcomings, propose modification suggestions, and help designer improve the ACR interface design. AHSIES consists of four programs: the UI Editor, the Operation Procedure Manager, the Operation Simulator and the UI Design Evaluator. These four parts respectively function for: editing a set of UI icons employed as the operation screens of an advanced control room; for editing operation procedures aiming at any specified operation with simple language; for simulate the operation sequences dynamically and recording the relevant information for design performance of the UIs; and for evaluating both static and dynamic performance of the ACR UI design according to well established design guidelines and criteria with the information gained from the first three programs. Microsoft SQL Server 2000 DBMS is adopted to manage the voluminous data and its complex relationships. The preliminary test application of AHSIES for a simplified ACR UI design of a PWR NPP has shown that the expert evaluation system is capable of achieving satisfactory evaluation results. (authors)

  4. Rapid antibiotic efficacy screening with aluminum oxide nanoporous membrane filter-chip and optical detection system.

    Science.gov (United States)

    Tsou, Pei-Hsiang; Sreenivasappa, Harini; Hong, Sungmin; Yasuike, Masayuki; Miyamoto, Hiroshi; Nakano, Keiyo; Misawa, Takeyuki; Kameoka, Jun

    2010-09-15

    We have developed a filter-chip and optical detection system for rapid antibiotic efficacy screening. The filter-chip consisted of a 1-mL reservoir and an anodic aluminum oxide (AAO) nanoporous membrane. Sample solution with liquid growth media, bacteria, and antibiotics was incubated in the reservoir for a specific period of time. The number of live bacteria on the surface of membrane was counted after the incubation with antibiotics and filtration. Using this biosensing system, we have demonstrated a 1-h antibiotic screening for patients' clinical samples, significantly faster than the conventional antibiotic susceptibility tests that typically take more than 24h. This rapid screening nature makes the filter-chip and detection system ideal for tailoring antibiotic treatment to individual patients by reducing the microbial antibiotic resistance, and improving the survival rate for patients suffering from postoperative infections. Published by Elsevier B.V.

  5. Technique charts for Kodak EC-L film screen system for portal localization in a 6MV X-ray beam.

    Science.gov (United States)

    Sandilos, P; Antypas, C; Paraskevopoulou, C; Kouvaris, J; Vlachos, L

    2006-01-01

    Port films are used in radiotherapy for visual evaluation of the radiation fields and subsequent quantitative analysis. Common port films suffer from poor image quality compared to the simulator-diagnostic films and is desirable to determine the appropriate exposure required for the best image contrast. The aim of this work is to generate technique charts for the Kodak EC-L film screen system for use in a 6MV x-ray beam. Three homogeneous water phantoms were used to simulate head-neck, thorax and abdomen dimensions of adult human, correspondingly. The film screen system was calibrated in a 6MV x-ray beam and under various irradiation conditions. The film screen system behavior was studied as a function of phantom thickness, field size and air gap between the phantom and the film screen system. In each case the optimum film exposure which produces the maximum image contrast was determined. The generated technique charts for the EC-L film screen system and for a 6 MV x-ray beam are used in our radiotherapy department for daily quality assurance of the radiotherapy procedure.

  6. Diagnostic Utility of the Social Skills Improvement System Performance Screening Guide

    Science.gov (United States)

    Krach, S. Kathleen; McCreery, Michael P.; Wang, Ye; Mohammadiamin, Houra; Cirks, Christen K.

    2017-01-01

    Researchers investigated the diagnostic utility of the Social Skills Improvement System: Performance Screening Guide (SSIS-PSG). Correlational, regression, receiver operating characteristic (ROC), and conditional probability analyses were run to compare ratings on the SSIS-PSG subscales of Prosocial Behavior, Reading Skills, and Math Skills, to…

  7. H and D curves of screen--film systems: factors affecting their dependence on x-ray energy

    International Nuclear Information System (INIS)

    Vyborny, C.J.

    1979-01-01

    The sensitometric properties of radiographic screen--film systems are investigated with regard to their dependence on x-ray energy. Sensitometric measurements and a heuristic model for density formation are used to show that variation in the relative amount of light emitted by front and back screens may be the most important factor influencing the change in system H and D curves with x-ray energy

  8. Screening for EIA in India: enhancing effectiveness through ecological carrying capacity approach.

    Science.gov (United States)

    Rajaram, T; Das, Ashutosh

    2011-01-01

    Developing countries across the world have embraced the policy of high economic growth as a means to reduce poverty. This economic growth largely based on industrial output is fast degrading the ecosystems, jeopardizing their long term sustainability. Environmental Impact Assessment (EIA) has long been recognized as a tool which can help in protecting the ecosystems and aid sustainable development. The Screening guidelines for EIA reflect the level of commitment the nation displays towards tightening its environmental protection system. The paper analyses the screening process for EIA in India and dissects the rationale behind the exclusions and thresholds set in the screening process. The screening process in India is compared with that of the European Union with the aim of understanding the extent of deviations from a screening approach in the context of better economic development. It is found that the Indian system excludes many activities from the purview of screening itself when compared to the EU. The constraints responsible for these exclusions are discussed and the shortcomings of the current command and control system of environmental management in India are also explained. It is suggested that an ecosystem carrying capacity based management system can provide significant inputs to enhance the effectiveness of EIA process from screening to monitoring. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Patterns and predictors of repeat fecal immunochemical and occult blood test screening in four large health care systems in the United States.

    Science.gov (United States)

    Singal, Amit G; Corley, Douglas A; Kamineni, Aruna; Garcia, Michael; Zheng, Yingye; Doria-Rose, Paul V; Quinn, Virginia P; Jensen, Christopher D; Chubak, Jessica; Tiro, Jasmin; Doubeni, Chyke A; Ghai, Nirupa R; Skinner, Celette Sugg; Wernli, Karen; Halm, Ethan A

    2018-02-27

    Effectiveness of fecal occult blood test (FOBT) for colorectal cancer (CRC) screening depends on annual testing, but little is known about patterns of repeat stool-based screening within different settings. Our study's objective was to characterize screening patterns and identify factors associated with repeat screening among patients who completed an index guaiac FOBT (gFOBT) or fecal immunochemical test (FIT). We performed a multi-center retrospective cohort study among people who completed a FOBT between January 2010 and December 2011 to characterize repeat screening patterns over the subsequent 3 years. We studied at 4 large health care delivery systems in the United States. Logistic regression analyses were used to identify factors associated with repeat screening patterns. We included individuals aged 50-71 years who completed an index FOBT and had at least 3 years of follow-up. We excluded people with a history of CRC, colonoscopy within 10 years or flexible sigmoidoscopy within 5 years before the index test, or positive index stool test. Consistent screening was defined as repeat FOBT within every 15 months and inconsistent screening as repeat testing at least once during follow-up but less than consistent screening. Among 959,857 eligible patients who completed an index FIT or gFOBT, 344,103 had three years of follow-up and met inclusion criteria. Of these, 46.6% had consistent screening, 43.4% inconsistent screening, and 10% had no repeat screening during follow-up. Screening patterns varied substantially across healthcare systems, with consistent screening proportions ranging from 1 to 54.3% and no repeat screening proportions ranging from 6.9 to 42.8%. Higher consistent screening proportions were observed in health systems with screening outreach and in-reach programs, whereas the safety-net health system, which uses opportunistic clinic-based screening, had the lowest consistent screening. Consistent screening increased with older age but was less

  10. The criteria for metabolic syndrome and the national health screening and education system in Japan

    Directory of Open Access Journals (Sweden)

    Kazumasa Yamagishi

    2017-01-01

    Full Text Available Two major definitions of metabolic syndrome have been proposed. One focuses on the accumulation of risk factors, a measure used by the American Heart Association (AHA and the National Heart, Lung, and Blood Institute (NHLBI; the other focuses on abdominal obesity, a measure used by the International Diabetes Federation (IDF and the Japanese government. The latter definition takes waist circumference (WC into consideration as an obligatory component, whereas the former does not. In 2009, the IDF, NHLBI, AHA, and other organizations attempted to unify these criteria; as a result, WC is no longer an obligatory component of those systems, while it remains obligatory in the Japanese criteria. In 2008, a new Japanese cardiovascular screening and education system focused on metabolic syndrome was launched. People undergoing screening are classified into three groups according to the presence of abdominal obesity and the number of metabolic risk factors, and receive health educational support from insurers. This system has yielded several beneficial outcomes: the visibility of metabolic syndrome at the population level has drastically improved; preventive measures have been directed toward metabolic syndrome, which is expected to become more prevalent in future generations; and a post-screening education system has been established. However, several problems with the current system have been identified and are under debate. In this review, we discuss topics related to metabolic syndrome, including (1 the Japanese criteria for metabolic syndrome; (2 metabolic syndrome and the universal health screening and education system; and (3 recent debates about Japanese criteria for metabolic syndrome.

  11. Socio-economic and demographic determinants affecting participation in the Swedish cervical screening program: A population-based case-control study.

    Science.gov (United States)

    Broberg, Gudrun; Wang, Jiangrong; Östberg, Anna-Lena; Adolfsson, Annsofie; Nemes, Szilard; Sparén, Pär; Strander, Björn

    2018-01-01

    Cervical screening programs are highly protective for cervical cancer, but only for women attending screening procedure. Identify socio-economic and demographic determinants for non-attendance in cervical screening. Design: Population-based case-control study. Setting: Sweden. Population: Source population was all women eligible for screening. Based on complete screening records, two groups of women aged 30-60 were compared. The case group, non-attending women, (N = 314,302) had no smear registered for 6-8 years. The control group (N = 266,706) attended within 90 days of invitation. Main outcome measures: Risk of non-attendance by 9 groups of socioeconomic and demographic variables. Analysis: Unadjusted odds ratios (OR) and OR after adjustment for all variables in logistic regression models were calculated. Women with low disposable family income (adjOR 2.06; 95% confidence interval (CI) 2.01-2.11), with low education (adjOR 1.77; CI 1.73-1.81) and not cohabiting (adjOR 1.47; CI 1.45-1.50) were more likely to not attend cervical screening. Other important factors for non-attendance were being outside the labour force and receiving welfare benefits. Swedish counties are responsible for running screening programs; adjusted OR for non-participation in counties ranged from OR 4.21 (CI 4.06-4.35) to OR 0.54 (CI 0.52-0.57), compared to the reference county. Being born outside Sweden was a risk factor for non-attendance in the unadjusted analysis but this disappeared in certain large groups after adjustment for socioeconomic factors. County of residence and socio-economic factors were strongly associated with lower attendance in cervical screening, while being born in another country was of less importance. This indicates considerable potential for improvement of cervical screening attendance in several areas if best practice of routines is adopted.

  12. A Novel Volumetric 3D Display System with Static Screen, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The physical world around us is three-dimensional (3D), yet most existing display systems with flat screens can handle only two-dimensional (2D) flat images that...

  13. Cervical cancer screening at crossroads

    DEFF Research Database (Denmark)

    Lynge, Elsebeth; Rygaard, Carsten; Baillet, Miguel Vazquez-Prada

    2014-01-01

    Cervical screening has been one of the most successful public health prevention programmes. For 50 years, cytology formed the basis for screening, and detected cervical intraepithelial lesions (CIN) were treated surgically to prevent progression to cancer. In a high-risk country as Denmark......, screening decreased the incidence of cervical cancer from 34 to 11 per 100,000, age-standardized rate (World Standard Population). Screening is, however, also expensive; Denmark (population: 5.6 million) undertakes close to half a million tests per year, and has 6-8 CIN-treated women for each prevented...... cancer case. The discovery of human papillomavirus (HPV) as the cause of cervical cancer dramatically changed perspectives for disease control. Screening with HPV testing was launched around 1990, and preventive HPV vaccination was licensed in 2006. Long-term randomized controlled trials (RCT...

  14. Women with learning disabilities and access to cervical screening: retrospective cohort study using case control methods

    Directory of Open Access Journals (Sweden)

    Stanistreet Debbi

    2008-01-01

    Full Text Available Abstract Background Several studies in the UK have suggested that women with learning disabilities may be less likely to receive cervical screening tests and a previous local study in had found that GPs considered screening unnecessary for women with learning disabilities. This study set out to ascertain whether women with learning disabilities are more likely to be ceased from a cervical screening programme than women without; and to examine the reasons given for ceasing women with learning disabilities. It was carried out in Bury, Heywood-and-Middleton and Rochdale. Methods Carried out using retrospective cohort study methods, women with learning disabilities were identified by Read code; and their cervical screening records were compared with the Call-and-Recall records of women without learning disabilities in order to examine their screening histories. Analysis was carried out using case-control methods – 1:2 (women with learning disabilities: women without learning disabilities, calculating odds ratios. Results 267 women's records were compared with the records of 534 women without learning disabilities. Women with learning disabilities had an odds ratio (OR of 0.48 (Confidence Interval (CI 0.38 – 0.58; X2: 72.227; p.value X2: 24.236; p.value X2: 286.341; p.value Conclusion The reasons given for ceasing and/or not screening suggest that merely being coded as having a learning disability is not the sole reason for these actions. There are training needs among smear takers regarding appropriate reasons not to screen and providing screening for women with learning disabilities.

  15. Supervisory control and diagnostics system for the mirror fusion test facility: overview and status 1980

    International Nuclear Information System (INIS)

    McGoldrick, P.R.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is a complex facility requiring a highly-computerized Supervisory Control and Diagnostics System (SCDS) to monitor and provide control over ten subsystems; three of which require true process control. SCDS will provide physicists with a method of studying machine and plasma behavior by acquiring and processing up to four megabytes of plasma diagnostic information every five minutes. A high degree of availability and throughput is provided by a distributed computer system (nine 32-bit minicomputers on shared memory). Data, distributed across SCDS, is managed by a high-bandwidth Distributed Database Management System. The MFTF operators' control room consoles use color television monitors with touch sensitive screens; this is a totally new approach. The method of handling deviations to normal machine operation and how the operator should be notified and assisted in the resolution of problems has been studied and a system designed

  16. Novel Stool-Based Protein Biomarkers for Improved Colorectal Cancer Screening: A Case-Control Study.

    Science.gov (United States)

    Bosch, Linda J W; de Wit, Meike; Pham, Thang V; Coupé, Veerle M H; Hiemstra, Annemieke C; Piersma, Sander R; Oudgenoeg, Gideon; Scheffer, George L; Mongera, Sandra; Sive Droste, Jochim Terhaar; Oort, Frank A; van Turenhout, Sietze T; Larbi, Ilhame Ben; Louwagie, Joost; van Criekinge, Wim; van der Hulst, Rene W M; Mulder, Chris J J; Carvalho, Beatriz; Fijneman, Remond J A; Jimenez, Connie R; Meijer, Gerrit A

    2017-12-19

    The fecal immunochemical test (FIT) for detecting hemoglobin is used widely for noninvasive colorectal cancer (CRC) screening, but its sensitivity leaves room for improvement. To identify novel protein biomarkers in stool that outperform or complement hemoglobin in detecting CRC and advanced adenomas. Case-control study. Colonoscopy-controlled referral population from several centers. 315 stool samples from one series of 12 patients with CRC and 10 persons without colorectal neoplasia (control samples) and a second series of 81 patients with CRC, 40 with advanced adenomas, and 43 with nonadvanced adenomas, as well as 129 persons without colorectal neoplasia (control samples); 72 FIT samples from a third independent series of 14 patients with CRC, 16 with advanced adenomas, and 18 with nonadvanced adenomas, as well as 24 persons without colorectal neoplasia (control samples). Stool samples were analyzed by mass spectrometry. Classification and regression tree (CART) analysis and logistic regression analyses were performed to identify protein combinations that differentiated CRC or advanced adenoma from control samples. Antibody-based assays for 4 selected proteins were done on FIT samples. In total, 834 human proteins were identified, 29 of which were statistically significantly enriched in CRC versus control stool samples in both series. Combinations of 4 proteins reached sensitivities of 80% and 45% for detecting CRC and advanced adenomas, respectively, at 95% specificity, which was higher than that of hemoglobin alone (P control samples (P control samples. Proof of concept that such proteins can be detected with antibody-based assays in small sample volumes indicates the potential of these biomarkers to be applied in population screening. Center for Translational Molecular Medicine, International Translational Cancer Research Dream Team, Stand Up to Cancer (American Association for Cancer Research and the Dutch Cancer Society), Dutch Digestive Foundation, and VU

  17. Digital I and C systems in nuclear power plants. Risk-screening of environmental stressors and a comparison of hardware unavailability with an existing analog system

    International Nuclear Information System (INIS)

    Hassan, M.; Vesely, W.E.

    1998-01-01

    In this report, we present a screening study to identify environmental stressors for digital instrumentation and control (I ampersand C) systems in a nuclear power plant (NPP) which can be potentially risk-significant, and compare the hardware unavailability of such a system with that of its existing analog counterpart. The stressors evaluated are temperature, humidity, vibration, radiation, electro-magnetic interference (EMI), and smoke. The results of risk-screening for an example plant, subject to some bounding assumptions and based on relative changes in plant risk (core damage frequency impacts of the stressors), indicate that humidity, EMI from lightning, and smoke can be potentially risk-significant. Risk from other sources of EMI could not be evaluated for a lack of data. Risk from temperature appears to be insignificant as that from the assumed levels of vibrations. A comparison of the hardware unavailability of the existing analog Safety Injection Actuation System (SIAS) in the example plant with that of an assumed digital upgrade of the system indicates that system unavailability may be more sensitive to the level of redundancy in elements of the digital system than to the environmental and operational variations involved. The findings of this study can be used to focus activities relating to the regulatory basis for digital I ampersand C upgrades in NPPs, including identification of dominant stressors, data-gathering, equipment qualification, and requirements to limit the effects of environmental stressors. 30 refs., 8 figs., 26 tabs

  18. Comparative performance of modern digital mammography systems in a large breast screening program

    Energy Technology Data Exchange (ETDEWEB)

    Yaffe, Martin J., E-mail: martin.yaffe@sri.utoronto.ca; Bloomquist, Aili K.; Hunter, David M.; Mawdsley, Gordon E. [Physical Sciences Division, Sunnybrook Research Institute, Departments of Medical Biophysics and Medical Imaging, University of Toronto, Ontario M4N 3M5 (Canada); Chiarelli, Anna M. [Prevention and Cancer Control, Cancer Care Ontario, Dalla Lana School of Public Health, University of Toronto, Ontario M4N 3M5, Canada and Ontario Breast Screening Program, Cancer Care Ontario, Toronto, Ontario M5G 1X3 (Canada); Muradali, Derek [Ontario Breast Screening Program, Cancer Care Ontario, Toronto, Ontario M5G 1X3 (Canada); Mainprize, James G. [Physical Sciences Division, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5 (Canada)

    2013-12-15

    Purpose: To compare physical measures pertaining to image quality among digital mammography systems utilized in a large breast screening program. To examine qualitatively differences in these measures and differences in clinical cancer detection rates between CR and DR among sites within that program. Methods: As part of the routine quality assurance program for screening, field measurements are made of several variables considered to correlate with the diagnostic quality of medical images including: modulation transfer function, noise equivalent quanta, d′ (an index of lesion detectability) and air kerma to allow estimation of mean glandular dose. In addition, images of the mammography accreditation phantom are evaluated. Results: It was found that overall there were marked differences between the performance measures of DR and CR mammography systems. In particular, the modulation transfer functions obtained with the DR systems were found to be higher, even for larger detector element sizes. Similarly, the noise equivalent quanta, d′, and the phantom scores were higher, while the failure rates associated with low signal-to-noise ratio and high dose were lower with DR. These results were consistent with previous findings in the authors’ program that the breast cancer detection rates at sites employing CR technology were, on average, 30.6% lower than those that used DR mammography. Conclusions: While the clinical study was not large enough to allow a statistically powered system-by-system assessment of cancer detection accuracy, the physical measures expressing spatial resolution, and signal-to-noise ratio are consistent with the published finding that sites employing CR systems had lower cancer detection rates than those using DR systems for screening mammography.

  19. Man-system interface based on automatic speech recognition: integration to a virtual control desk

    Energy Technology Data Exchange (ETDEWEB)

    Jorge, Carlos Alexandre F.; Mol, Antonio Carlos A.; Pereira, Claudio M.N.A.; Aghina, Mauricio Alves C., E-mail: calexandre@ien.gov.b, E-mail: mol@ien.gov.b, E-mail: cmnap@ien.gov.b, E-mail: mag@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Nomiya, Diogo V., E-mail: diogonomiya@gmail.co [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil)

    2009-07-01

    This work reports the implementation of a man-system interface based on automatic speech recognition, and its integration to a virtual nuclear power plant control desk. The later is aimed to reproduce a real control desk using virtual reality technology, for operator training and ergonomic evaluation purpose. An automatic speech recognition system was developed to serve as a new interface with users, substituting computer keyboard and mouse. They can operate this virtual control desk in front of a computer monitor or a projection screen through spoken commands. The automatic speech recognition interface developed is based on a well-known signal processing technique named cepstral analysis, and on artificial neural networks. The speech recognition interface is described, along with its integration with the virtual control desk, and results are presented. (author)

  20. Man-system interface based on automatic speech recognition: integration to a virtual control desk

    International Nuclear Information System (INIS)

    Jorge, Carlos Alexandre F.; Mol, Antonio Carlos A.; Pereira, Claudio M.N.A.; Aghina, Mauricio Alves C.; Nomiya, Diogo V.

    2009-01-01

    This work reports the implementation of a man-system interface based on automatic speech recognition, and its integration to a virtual nuclear power plant control desk. The later is aimed to reproduce a real control desk using virtual reality technology, for operator training and ergonomic evaluation purpose. An automatic speech recognition system was developed to serve as a new interface with users, substituting computer keyboard and mouse. They can operate this virtual control desk in front of a computer monitor or a projection screen through spoken commands. The automatic speech recognition interface developed is based on a well-known signal processing technique named cepstral analysis, and on artificial neural networks. The speech recognition interface is described, along with its integration with the virtual control desk, and results are presented. (author)

  1. Effect of two different house screening interventions on exposure to malaria vectors and on anaemia in children in The Gambia: a randomised controlled trial.

    Science.gov (United States)

    Kirby, Matthew J; Ameh, David; Bottomley, Christian; Green, Clare; Jawara, Musa; Milligan, Paul J; Snell, Paul C; Conway, David J; Lindsay, Steve W

    2009-09-19

    House screening should protect people against malaria. We assessed whether two types of house screening--full screening of windows, doors, and closing eaves, or installation of screened ceilings--could reduce house entry of malaria vectors and frequency of anaemia in children in an area of seasonal malaria transmission. During 2006 and 2007, 500 occupied houses in and near Farafenni town in The Gambia, an area with low use of insecticide-treated bednets, were randomly assigned to receive full screening, screened ceilings, or no screening (control). Randomisation was done by computer-generated list, in permuted blocks of five houses in the ratio 2:2:1. Screening was not treated with insecticide. Exposure to mosquitoes indoors was assessed by fortnightly light trap collections during the transmission season. Primary endpoints included the number of female Anopheles gambiae sensu lato mosquitoes collected per trap per night. Secondary endpoints included frequency of anaemia (haemoglobin concentration ceilings, n=178; control, n=96). The mean number of A gambiae caught in houses without screening was 37.5 per trap per night (95% CI 31.6-43.3), compared with 15.2 (12.9-17.4) in houses with full screening (ratio of means 0.41, 95% CI 0.31-0.54; pceilings (ratio 0.53, 0.40-0.70; pceilings (OR 0.51, 0.27-0.96; p=0.04). Frequency of parasitaemia did not differ between intervention and control groups. House screening substantially reduced the number of mosquitoes inside houses and could contribute to prevention of anaemia in children. Medical Research Council.

  2. Cervical cancer screening and adherence to follow-up among Hispanic women study protocol: a randomized controlled trial to increase the uptake of cervical cancer screening in Hispanic women

    Directory of Open Access Journals (Sweden)

    Duggan Catherine

    2012-05-01

    Full Text Available Abstract Background In the US, Hispanic women have a higher incidence of, and mortality from, cervical cancer than non-Hispanic white women. The reason for this disparity may be attributable to both low rates of screening and poor adherence to recommended diagnostic follow-up after an abnormal Pap test. The 'Cervical Cancer Screening and Adherence to Follow-up Among Hispanic Women' study is a collaboration between a research institution and community partners made up of members from community based organizations, the Yakima Valley Farm Workers Clinic and the Breast, Cervical, and Colon Health Program of the Yakima District . The study will assess the efficacy of two culturally-appropriate, tailored educational programs designed to increase cervical cancer screening among Hispanic women, based in the Yakima Valley, Washington, US. Methods/design A parallel randomized-controlled trial of 600 Hispanic women aged 21–64, who are non-compliant with Papanicolau (Pap test screening guidelines. Participants will be randomized using block randomization to (1 a control arm (usual care; (2 a low-intensity information program, consisting of a Spanish-language video that educates women on the importance of cervical cancer screening; or (3 a high-intensity program consisting of the video plus a ‘promotora’ or lay-community health educator-led, home based intervention to encourage cervical cancer screening. Participants who attend cervical cancer screening, and receive a diagnosis of an abnormal Pap test will be assigned to a patient navigator who will provide support and information to promote adherence to follow-up tests, and any necessary surgery or treatment. Primary endpoint: Participants will be tracked via medical record review at community-based clinics, to identify women who have had a Pap test within 7 months of baseline assessment. Medical record reviewers will be blinded to randomization arm. Secondary endpoint: An evaluation of the patient

  3. Spallation Neutron Source Accelerator Facility Target Safety and Non-safety Control Systems

    International Nuclear Information System (INIS)

    Battle, Ronald E.; DeVan, B.; Munro, John K. Jr.

    2006-01-01

    The Spallation Neutron Source (SNS) is a proton accelerator facility that generates neutrons for scientific researchers by spallation of neutrons from a mercury target. The SNS became operational on April 28, 2006, with first beam on target at approximately 200 W. The SNS accelerator, target, and conventional facilities controls are integrated by standardized hardware and software throughout the facility and were designed and fabricated to SNS conventions to ensure compatibility of systems with Experimental Physics Integrated Control System (EPICS). ControlLogix Programmable Logic Controllers (PLCs) interface to instruments and actuators, and EPICS performs the high-level integration of the PLCs such that all operator control can be accomplished from the Central Control room using EPICS graphical screens that pass process variables to and from the PLCs. Three active safety systems were designed to industry standards ISA S84.01 and IEEE 603 to meet the desired reliability for these safety systems. The safety systems protect facility workers and the environment from mercury vapor, mercury radiation, and proton beam radiation. The facility operators operated many of the systems prior to beam on target and developed the operating procedures. The safety and non-safety control systems were tested extensively prior to beam on target. This testing was crucial to identify wiring and software errors and failed components, the result of which was few problems during operation with beam on target. The SNS has continued beam on target since April to increase beam power, check out the scientific instruments, and continue testing the operation of facility subsystems

  4. ScreenOS Cookbook

    CERN Document Server

    Brunner, Stefan; Delcourt, David

    2008-01-01

    In the only book that completely covers ScreenOS, six key members of Juniper Network's ScreenOS development team help you troubleshoot secure networks using ScreenOS firewall appliances. Over 200 recipes address a wide range of security issues, provide step-by-step solutions, and include discussions of why the recipes work, so you can easily set up and keep ScreenOS systems on track. The easy-to-follow format enables you to find the topic and specific recipe you need right away.

  5. Training set optimization and classifier performance in a top-down diabetic retinopathy screening system

    Science.gov (United States)

    Wigdahl, J.; Agurto, C.; Murray, V.; Barriga, S.; Soliz, P.

    2013-03-01

    Diabetic retinopathy (DR) affects more than 4.4 million Americans age 40 and over. Automatic screening for DR has shown to be an efficient and cost-effective way to lower the burden on the healthcare system, by triaging diabetic patients and ensuring timely care for those presenting with DR. Several supervised algorithms have been developed to detect pathologies related to DR, but little work has been done in determining the size of the training set that optimizes an algorithm's performance. In this paper we analyze the effect of the training sample size on the performance of a top-down DR screening algorithm for different types of statistical classifiers. Results are based on partial least squares (PLS), support vector machines (SVM), k-nearest neighbor (kNN), and Naïve Bayes classifiers. Our dataset consisted of digital retinal images collected from a total of 745 cases (595 controls, 150 with DR). We varied the number of normal controls in the training set, while keeping the number of DR samples constant, and repeated the procedure 10 times using randomized training sets to avoid bias. Results show increasing performance in terms of area under the ROC curve (AUC) when the number of DR subjects in the training set increased, with similar trends for each of the classifiers. Of these, PLS and k-NN had the highest average AUC. Lower standard deviation and a flattening of the AUC curve gives evidence that there is a limit to the learning ability of the classifiers and an optimal number of cases to train on.

  6. Controlled carrier screening in p-n NiO/GaN piezoelectric generators by an Al2O3 insertion layer

    Science.gov (United States)

    Johar, Muhammad Ali; Jeong, Dae Kyung; Afifi Hassan, Mostafa; Kang, Jin-Ho; Ha, Jun-Seok; Key Lee, June; Ryu, Sang-Wan

    2017-12-01

    The performance of a piezoelectric generator (PG) depends significantly on the internal screening process inside the device. As piezoelectric charges appear on both ends of the piezoelectric crystal, internal screening starts to decrease the piezoelectric bias. Therefore, the piezoelectric energy generated by external stress is not fully utilized by external circuit, which is the most challenging aspect of high-efficiency PGs. In this work, the internal screening effect of a NiO/GaN p-n PG was analyzed and controlled with an Al2O3 insertion layer. Internal screening in the p-n diode PG was categorized into free-carrier screening in neutral regions and junction screening due to charge drift across the junction. It was observed that junction screening could be significantly suppressed by inserting an Al2O3 layer and that effect was dominant in a leaky diode PG. With this implementation, the piezoelectric bias of the NiO/GaN PG was improved by a factor of ~100 for high-leakage diodes and a factor of ~1.6 for low-leakage diodes. Consequently, NiO/Al2O3/GaN PGs under a stress of 5 MPa provided a piezoelectric bias of 12.1 V and a current density of 2.25 µA cm-2. The incorporation of a highly resistive Al2O3 layer between p-NiO and n-GaN layers in NiO/GaN heterojunctions provides an efficient means of improving the piezoelectric performance by controlling the internal screening of the piezoelectric field.

  7. Photon attenuation by intensifying screens

    International Nuclear Information System (INIS)

    Holje, G.

    1983-01-01

    The photon attenuation by intensifying screens of different chemical composition has been determined. The attenuation of photons between 20 keV and 120 keV was measured by use of a multi-channel analyzer and a broad bremsstrahlung distribution. The attenuation by the intensifying screens was hereby determined simultaneously at many different monoenergetic photon energies. Experimentally determined attenuations were found to agree well with attenuation calculated from mass attenuation coefficients. The attenuation by the screens was also determined at various bremsstrahlung distributions, simulating those occurring behind the patient in various diagnostic X-ray examinations. The high attenuation in some of the intensifying screens form the basis for an analysis of the construction of asymmetric screen pairs. Single screen systems are suggested as a favourable alternative to thick screen pair systems. (Author)

  8. Smartphone-based cyclic voltammetry system with graphene modified screen printed electrodes for glucose detection.

    Science.gov (United States)

    Ji, Daizong; Liu, Lei; Li, Shuang; Chen, Chen; Lu, Yanli; Wu, Jiajia; Liu, Qingjun

    2017-12-15

    Smartphone-based electrochemical devices have such advantages as the low price, miniaturization, and obtaining the real-time data. As a popular electrochemical method, cyclic voltammetry (CV) has shown its great practicability for quantitative detection and electrodes modification. In this study, a smartphone-based CV system with a simple method of electrode modification was constructed to perform electrochemical detections. The system was composed of these main portions: modified electrodes, portable electrochemical detector and smartphone. Among them, the detector was comprised of an energy transformation module applying the stimuli signals, and a low-cost potentiostat module for CV measurements with a Bluetooth module for transmitting data and commands. With an Application (App), the smartphone was used as the controller and displayer of the system. Through controlling of different scan rates, the smartphone-based system could perform CV detections for redox couples with test errors less than 3.8% compared to that of commercial electrochemical workstation. Also, the reduced graphene oxide (rGO) and sensitive substance could be modified by the system on the screen printed electrodes for detections. As a demonstration, 3-amino phenylboronic acid (APBA) was used as the sensitive substance to fabricate a glucose sensor. Finally, the experimental data of the system were shown the linear, sensitive, and specific responses to glucose at different doses, even in blood serum as low as about 0.026mM with 3δ/slope calculation. Thus, the system could show great potentials of detection and modification of electrodes in various fields, such as public health, water monitoring, and food quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Risk Stratification and Shared Decision Making for Colorectal Cancer Screening: A Randomized Controlled Trial.

    Science.gov (United States)

    Schroy, Paul C; Duhovic, Emir; Chen, Clara A; Heeren, Timothy C; Lopez, William; Apodaca, Danielle L; Wong, John B

    2016-05-01

    Eliciting patient preferences within the context of shared decision making has been advocated for colorectal cancer (CRC) screening, yet providers often fail to comply with patient preferences that differ from their own. To determine whether risk stratification for advanced colorectal neoplasia (ACN) influences provider willingness to comply with patient preferences when selecting a desired CRC screening option. Randomized controlled trial. Asymptomatic, average-risk patients due for CRC screening in an urban safety net health care setting. Patients were randomized 1:1 to a decision aid alone (n= 168) or decision aid plus risk assessment (n= 173) arm between September 2012 and September 2014. The primary outcome was concordance between patient preference and test ordered; secondary outcomes included patient satisfaction with the decision-making process, screening intentions, test completion rates, and provider satisfaction. Although providers perceived risk stratification to be useful in selecting an appropriate screening test for their average-risk patients, no significant differences in concordance were observed between the decision aid alone and decision aid plus risk assessment groups (88.1% v. 85.0%,P= 0.40) or high- and low-risk groups (84.5% v. 87.1%,P= 0.51). Concordance was highest for colonoscopy and relatively low for tests other than colonoscopy, regardless of study arm or risk group. Failure to comply with patient preferences was negatively associated with satisfaction with the decision-making process, screening intentions, and test completion rates. Single-institution setting; lack of provider education about the utility of risk stratification into their decision making. Providers perceived risk stratification to be useful in their decision making but often failed to comply with patient preferences for tests other than colonoscopy, even among those deemed to be at low risk of ACN. © The Author(s) 2016.

  10. ANALYSIS OF THE PROCESSES IN AN INDUCTOR SYSTEM WITH AN ATTRACTING SCREEN EXCITED BY THE EXTERNAL CIRCULAR SOLENOID

    Directory of Open Access Journals (Sweden)

    E.A. Chaplygin

    2015-12-01

    Full Text Available Introduction. Developments in the field of magnetic-pulse treatment of metals (MPTM are increasingly used in the modern technologies of production and repair of the aviation, automotive and other machinery, as they are environmentally friendly and energy-efficient in comparison with classical approaches. One of the main components of the device MPTM is a tool – inductor or the inductor system with an attractive screen (ISAS. The calculated dependences to calculate the inductor system with an attractive screen were taken from previous works. The ratios were obtained for the low-frequency mode of the excited fields, when is place their significant penetration through a thin-walled metal screen and a deformed workpiece. As it was shown earlier this mode is the most efficient from point of view of a force action on the object of a processing. Purpose. The theoretical analysis of the spatial-temporal distributions of the induced currents and forces of an attraction in the inductor system with an attractive screen excited by a flat circular solenoid located on the outside of the auxiliary screen. Methodology. The calculations are shown that the induced currents both in the screen and the workpiece are unidirectional and their interaction, in accordance with the law of Ampere determines the amplitudes of excited forces of attraction. Let’s note the effective validity of the considered inductor system excited by an external circular solenoid. With sufficient simplicity of the design take place rather high values of the developed forces of attraction and their averages. Results. Physically, a higher power efficiency of the system with an «external» coil in comparison with a system where coil is located in the internal cavity, can be accounted for lade of «failure» in the radial distribution of the excited forces. This «failure» in the design with a coil between the sheet metal is caused by its screening action against the forces of attraction

  11. The Baker system for nuclear access authorization screening: a psychologically developed system for access screening of vendor and owner applicants at nuclear power plants

    International Nuclear Information System (INIS)

    Baker, E.G.; Crouter, F.L.

    1985-01-01

    This paper presents a comprehensive screening program for unescorted access which has proven to be highly effective in determining the intergrity, trustworthiness, socialibility, behaviors and tendencies of an employee applicant--past, present and future. This procedure, designed specifically for the nuclear industry, can be used with owner or vendor applicants, and meets or exceeds all of the NRC's requirements. The Baker system has been used for nuclear selection since 1979

  12. Comparison of low contrast detectability of computed tomography and screen/film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan Hoong Ng; McLean, D.

    2006-01-01

    The objective of this study was to compare low contrast detectability of computed radiography (CR) and screen/film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significant of the difference of contrast between CR and SF, and for each exposure parameter was tested using non-parametric Kruskal-Wallis test. We found that the low contrast detectability of CR (soft copy and hard copy) system is not significantly different to that of SF system (p>0.05, Kruskal-Wallis test). For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low contrast objects such as small low contrast areas corresponding to breast pathology

  13. Approaching the Hard-to-Reach in Organized Colorectal Cancer Screening: an Overview of Individual, Provider and System Level Coping Strategies

    Directory of Open Access Journals (Sweden)

    Jason Liwen Huang

    2017-06-01

    Full Text Available Background: Despite the proven effectiveness of colorectal cancer (CRC screening on reduction of CRC mortality, the uptake of CRC screening remains low. Participation rate is one of determinants for the success of organized population-based screening program. This review aims to identify those who are hard-to-reach, and summarize the strategies to increase their screening rate from individual, provider and system levels. Methods: A systematic search of electronic English databases was conducted on the factors and strategies of uptake in CRC screening for the hard-to-reach population up to May 2017. Discussion: The coverage rate and participation rate are two indexes to identify the hard-to-reach population in organized CRC screening program. However, the homeless, new immigrants, people with severe mental illness, the jail intimates, and people with characteristics including lower education levels and/or low socioeconomic status, living in rural/remote areas, without insurance, and racial minorities are usually recognized as hard-to-reach populations. For them, organized screening programs offer a better coverage, while novel invitation approaches for eligible individuals and multiple strategies from primary care physicians are still needed to enhance screening rates among subjects who are hard-to-reach. Suggestions implied the effectiveness of interventions at the system level, including linkages to general practice; use of decision making tools; enlisting supports from coalition; and the continuum from screening to diagnosis and treatment. Conclusion: Organized CRC screening offers a system access to approach the hard-to-reach populations. To increase their uptake, multiple and novel strategies from individual, provider and system levels should be applied. For policymakers, public healthcare providers and community stakeholders, it is a test to tailor their potential needs and increase their participation rates through continuous efforts to

  14. Performance of the colorectal cancer screening marker Sept9 is influenced by age, diabetes and arthritis: a nested case-control study

    DEFF Research Database (Denmark)

    Ørntoft, Mai-Britt Worm; Nielsen, Hans Jørgen; Ørntoft, Torben Falck

    2015-01-01

    Background Annually, colorectal cancer (CRC) is diagnosed in >1.4 million subjects worldwide and incidence is increasing. Much effort has therefore been focused on screening, which has proven to reduce cancer-related mortality. The Sept9 DNA-methylation assay is among the most well studied blood......-based screening markers. However, earlier reported performances may be misleading: the Sept9 test was recently examined in two screening based cohorts and yielded performances lower than expected. We hypothesize that comorbidities and/or demographic characteristics affect the results of the Sept9 test. Methods...... Using a retrospective nested case–control study design, we studied plasma from 150 cancer and 150 controls selected from a well-characterized cohort of 4698 subjects referred for diagnostic colonoscopy due to CRC-related symptoms. The cases and controls were matched on age and gender, and moreover cases...

  15. Integrated control systems

    International Nuclear Information System (INIS)

    Smith, D.J.

    1991-01-01

    This paper reports that instrument manufacturers must develop standard network interfaces to pull together interrelated systems such as automatic start-up, optimization programs, and online diagnostic systems. In the past individual control system manufacturers have developed their own data highways with proprietary hardware and software designs. In the future, electric utilities will require that future systems, irrespective of manufacturer, should be able to communicate with each other. Until now the manufactures of control systems have not agreed on the standard high-speed data highway system. Currently, the Electric Power Research Institute (EPRI), in conjunction with several electric utilities and equipment manufactures, is working on developing a standard protocol for communicating between various manufacturers' control systems. According to N. Michael of Sargent and Lundy, future control room designs will require that more of the control and display functions be accessible from the control room through CRTs. There will be less emphasis on traditional hard-wired control panels

  16. VISUALISASI DAN NAVIGASI MEDIA PENYIMPANAN DISK DENGAN MENGGUNAKAN METODE SPLIT SCREEN SYSTEM

    Directory of Open Access Journals (Sweden)

    Yulia yulia

    2002-01-01

    Full Text Available Disk is a very useful device to a computer to save data file. For that, is much needed to have a program that has a capability to represent, navigate, and operate that files. There are many computer programs that used to present, navigate, and operate disk files in text form with a lot of facilities, but only a few programs that can represent files in a graphic form and have special feature, like capability to find the biggest files that use disk space. This capability is very useful in disk file management. This software use split screen system method and tree map algorithm. Split screen system is used to navigate, where the monitor screen divided into two parts to visualize files in a disk, the small part (map navigator visualize the whole content of a drive or directory and the big part visualize the detail of a part according to focus box in the map navigator. A mouse can move focus box in the map navigator and the box size is the comparison between map navigator sizes with map view size. Tree map algorithm is used to calculate the size of box picture of the represented file. This algorithm needs a complete tree structure from a drive or directory that will be painted. The software to make this windows based program is Borland Delphi 5.0. Abstract in Bahasa Indonesia : Disk merupakan alat yang sangat bermanfaat bagi sebuah sistem komputer untuk menyimpan data berupa file. Untuk itu sangat dibutuhkan program yang dapat merepresentasikan, menavigasi dan mengoperasikan file-file tersebut. Banyak program komputer yang digunakan untuk merepresentasikan, menavigasi dan mengoperasikan file-file pada media penyimpanan disk dalam bentuk teks dengan berbagai macam fasilitas, tetapi sangat sedikit program yang merepresentasikan file-file dalam bentuk grafik atau secara visual serta mampu memberikan kelebihan-kelebihan tersendiri, seperti kemampuan untuk merepresentasikan file-file yang paling banyak menggunakan ruang media penyimpanan disk. Kemampuan

  17. Shared decision making for prostate cancer screening: the results of a combined analysis of two practice-based randomized controlled trials.

    Science.gov (United States)

    Sheridan, Stacey L; Golin, Carol; Bunton, Audrina; Lykes, John B; Schwartz, Bob; McCormack, Lauren; Driscoll, David; Bangdiwala, Shrikant I; Harris, Russell P

    2012-11-13

    Professional societies recommend shared decision making (SDM) for prostate cancer screening, however, most efforts have promoted informed rather than shared decision making. The objective of this study is to 1) examine the effects of a prostate cancer screening intervention to promote SDM and 2) determine whether framing prostate information in the context of other clearly beneficial men's health services affects decisions. We conducted two separate randomized controlled trials of the same prostate cancer intervention (with or without additional information on more clearly beneficial men's health services). For each trial, we enrolled a convenience sample of 2 internal medicine practices, and their interested physicians and male patients with no prior history of prostate cancer (for a total of 4 practices, 28 physicians, and 128 men across trials). Within each practice site, we randomized men to either 1) a video-based decision aid and researcher-led coaching session or 2) a highway safety video. Physicians at each site received a 1-hour educational session on prostate cancer and SDM. To assess intervention effects, we measured key components of SDM, intent to be screened, and actual screening. After finding that results did not vary by trial, we combined data across sites, adjusting for the random effects of both practice and physician. Compared to an attention control, our prostate cancer screening intervention increased men's perceptions that screening is a decision (absolute difference +41%; 95% CI 25 to 57%) and men's knowledge about prostate cancer screening (absolute difference +34%; 95% CI 19% to 50%), but had no effect on men's self-reported participation in shared decisions or their participation at their preferred level. Overall, the intervention decreased screening intent (absolute difference -34%; 95% CI -50% to -18%) and actual screening rates (absolute difference -22%; 95% CI -38 to -7%) with no difference in effect by frame. SDM interventions can

  18. A clinical trial of a rare earth screen/film system in a periapical cassette

    International Nuclear Information System (INIS)

    Kogon, S.L.; Stephens, R.G.; Reid, J.A.; Lubus, N.J.

    1984-01-01

    In a clinical trial, a slow rare earth screen/film system (Siemens Titan 2D/Kodak XG) was used to obtain intraoral radiographs at conventional monitoring stages in endodontic treatment. The screen film image proved to be an effective substitute for the direct-exposure Ultraspeed periapical film. The intraoral cassettes, designed and fabricated for the study, were an adaptation of the flexible, vacuum-sealed cassettes used in mammography. It is believed that when a practicable periapical cassette is manufactured, many additional indications for the system are probable. Major reductions in patient exposure of at least 85% to 90% per periapical film would be effected

  19. Eurogin 2016 Roadmap: how HPV knowledge is changing screening practice.

    Science.gov (United States)

    Wentzensen, Nicolas; Arbyn, Marc; Berkhof, Johannes; Bower, Mark; Canfell, Karen; Einstein, Mark; Farley, Christopher; Monsonego, Joseph; Franceschi, Silvia

    2017-05-15

    Human papillomaviruses (HPVs) are the necessary cause of most cervical cancers, a large proportion of other anogenital cancers, and a subset of oropharyngeal cancers. The knowledge about HPV has led to development of novel HPV-based prevention strategies with important impact on clinical and public health practice. Two complementary reviews have been prepared following the 2015 Eurogin Conference to evaluate how knowledge about HPV is changing practice in HPV infection and disease control through vaccination and screening. This review focuses on screening for cervical and anal cancers in increasingly vaccinated populations. The introduction of HPV vaccines a decade ago has led to reductions in HPV infections and early cancer precursors in countries with wide vaccination coverage. Despite the high efficacy of HPV vaccines, cervical cancer screening will remain important for many decades. Many healthcare systems are considering switching to primary HPV screening, which has higher sensitivity for cervical precancers and allows extending screening intervals. We describe different approaches to implementing HPV-based screening efforts in different healthcare systems with a focus in high-income countries. While the population prevalence for other anogenital cancers is too low for population-based screening, anal cancer incidence is very high in HIV-infected men who have sex with men, warranting consideration of early detection approaches. We summarize the current evidence on HPV-based prevention of anal cancers and highlight important evidence gaps. © 2016 UICC.

  20. Reactor control system. PWR

    International Nuclear Information System (INIS)

    2009-01-01

    At present, 23 units of PWR type reactors have been operated in Japan since the start of Mihama Unit 1 operation in 1970 and various improvements have been made to upgrade operability of power stations as well as reliability and safety of power plants. As the share of nuclear power increases, further improvements of operating performance such as load following capability will be requested for power stations with more reliable and safer operation. This article outlined the reactor control system of PWR type reactors and described the control performance of power plants realized with those systems. The PWR control system is characterized that the turbine power is automatic or manually controlled with request of the electric power system and then the nuclear power is followingly controlled with the change of core reactivity. The system mainly consists of reactor automatic control system (control rod control system), pressurizer pressure control system, pressurizer water level control system, steam generator water level control system and turbine bypass control system. (T. Tanaka)

  1. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  2. BSF control system

    International Nuclear Information System (INIS)

    Irie, Y.; Ishii, K.; Ninomiya, S.; Sasaki, H.; Sakai, I.

    1982-08-01

    The booster synchrotron utilization facility (BSF) is a facility which utilizes the four fifths of available beam pulses from the KEK booster synchrotron. The BSF control system includes the beam line control, interactions with the PS central control room and the experimental facilities, and the access control system. A brief description of the various components in the control system is given. (author)

  3. Reduced Bone Mineral Density in Children With Screening-detected Celiac Disease.

    Science.gov (United States)

    Björck, Sara; Brundin, Charlotte; Karlsson, Magnus; Agardh, Daniel

    2017-11-01

    The aim of the study was to assess whether bone mass and metabolism are impaired in genetically at-risk children with screening-detected celiac disease. Included were 71 children with screening-detected celiac disease diagnosed at 10.0 ± 0.7 (mean ± standard deviation) years and 142 matched controls and 30 children with screening-detected celiac disease diagnosed at 3.3 ± 0.4 years of age presently on a gluten-free diet for 6.9 ± 1.1 years and 60 matched controls. All participants were assessed for bone mineral density (BMD) of total body and spine by dual x-ray absorptiometry, serum 25(OH) vitamin D3, parathyroid hormone (PTH), interleukin (IL)-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-15, interferon gamma, and tumor necrosis factor alpha. At diagnosis, screening-detected celiac disease children as compared to controls had a mean -0.03 g/cm reduced BMD of both total body and spine (P = 0.009 and P = 0.005, respectively), a mean -11.4 nmol/L lower level of 25(OH) vitamin D3 (P celiac disease as compared to controls (P celiac disease have reduced BMD, lower levels of vitamin D3, higher levels of PTH, and signs of systemic inflammation compared with controls. These differences were not found in celiac disease children on a gluten-free diet, indicating that children with screening-detected celiac disease benefit from an early diagnosis and treatment.

  4. Novel high-throughput screening system for identifying STAT3-SH2 antagonists

    International Nuclear Information System (INIS)

    Uehara, Yutaka; Mochizuki, Masato; Matsuno, Kenji; Haino, Takeharu; Asai, Akira

    2009-01-01

    Constitutive activation of the oncogenic transcription factor STAT3 frequently occurs in various human malignancies. STAT3 activation involves dimerization via intermolecular pTyr-SH2 interaction. Thus, antagonizing this interaction is a feasible approach to inhibit STAT3 activation for cancer therapy. In order to identify selective STAT3 inhibitors, we developed a biochemical HTS system based on AlphaScreen technology, which measures the abilities of test compounds to antagonize pTyr-SH2 interactions. We screened our chemical libraries using this system and identified 5,15-diphenylporphyrin (5,15-DPP) as a selective STAT3-SH2 antagonist. Selective inhibition of STAT3 nuclear translocation and DNA biding activity was observed in cells treated with 5,15-DPP. IL-6-dependent dimerization of STAT3, c-myc promoter binding and c-myc protein expression were all suppressed by 5,15-DPP, whereas no decrement in either expression or phosphorylation level of STAT3 was observed. Thus, the HTS assay system represented herein may be useful for identifying novel STAT3-SH2 antagonists.

  5. The Human Eye Position Control System in a Rehabilitation Setting

    Directory of Open Access Journals (Sweden)

    Yvonne Nolan

    2005-01-01

    Full Text Available Our work at Ireland’s National Rehabilitation Hospital involves designing communication systems for people suffering from profound physical disabilities. One such system uses the electro-oculogram, which is an (x,y system of voltages picked up by pairs of electrodes placed, respectively, above and below and on either side of the eyes. The eyeball has a dc polarisation between cornea and back, arising from the photoreceptor rods and cones in the retina. As the eye rotates, the varying voltages projected onto the electrodes drive a cursor over a mimic keyboard on a computer screen. Symbols are selected with a switching action derived, for example, from a blink. Experience in using this mode of communication has given us limited facilities to study the eye position control system. We present here a resulting new feedback model for rotation in either the vertical or the horizontal plane, which involves the eyeball controlled by an agonist-antagonist muscle pair, modelled by a single equivalent bidirectional muscle with torque falling off linearly with angular velocity. We have incorporated muscle spindles and have tuned them by pole assignment associated with an optimum stability criterion.

  6. The health system and population health implications of large-scale diabetes screening in India: a microsimulation model of alternative approaches.

    Directory of Open Access Journals (Sweden)

    Sanjay Basu

    2015-05-01

    Full Text Available Like a growing number of rapidly developing countries, India has begun to develop a system for large-scale community-based screening for diabetes. We sought to identify the implications of using alternative screening instruments to detect people with undiagnosed type 2 diabetes among diverse populations across India.We developed and validated a microsimulation model that incorporated data from 58 studies from across the country into a nationally representative sample of Indians aged 25-65 y old. We estimated the diagnostic and health system implications of three major survey-based screening instruments and random glucometer-based screening. Of the 567 million Indians eligible for screening, depending on which of four screening approaches is utilized, between 158 and 306 million would be expected to screen as "high risk" for type 2 diabetes, and be referred for confirmatory testing. Between 26 million and 37 million of these people would be expected to meet international diagnostic criteria for diabetes, but between 126 million and 273 million would be "false positives." The ratio of false positives to true positives varied from 3.9 (when using random glucose screening to 8.2 (when using a survey-based screening instrument in our model. The cost per case found would be expected to be from US$5.28 (when using random glucose screening to US$17.06 (when using a survey-based screening instrument, presenting a total cost of between US$169 and US$567 million. The major limitation of our analysis is its dependence on published cohort studies that are unlikely fully to capture the poorest and most rural areas of the country. Because these areas are thought to have the lowest diabetes prevalence, this may result in overestimation of the efficacy and health benefits of screening.Large-scale community-based screening is anticipated to produce a large number of false-positive results, particularly if using currently available survey-based screening

  7. A Novel Miniature Culture System to Screen CO2-Sequestering Microalgae

    Directory of Open Access Journals (Sweden)

    Xiaoling Miao

    2012-11-01

    Full Text Available In this study, a novel 96-well microplate swivel system (M96SS was built for high-throughput screening of microalgal strains for CO2 fixation. Cell growth under different CO2 supply conditions (0.2, 0.4, 0.8, and 1.2 g L−1 d−1, residual nitrate, and pH value of Chlorella sp. SJTU-3, Chlorella pyrenoidosa SJTU-2, and Scenedesmus obliquus SJTU-3 were examined in the M96SS and traditional flask cultures. The dynamic data showed there was a good agreement between the systems. Two critical problems in miniature culture systems (intra-well mixing and evaporation loss were improved by sealed vertical mixing of the M96SS. A sample screen of six microalgal species (Chlorella sp. SJTU-3, Chlorella pyrenoidosa SJTU-2, Selenastrum capricornutum, Scenedesmus obliquus SJTU-3, Chlamydomonas sajao, Dunaliella primolecta was carried out in flasks and the M96SS. Chlamydomonas sajao appeared to be a robust performer (highest cell density: 1.437 g L−1 in anaerobic pond water with 0.8, and 1.2 g L−1 d−1 CO2. The reliability and efficiency of the M96SS were verified through a comparison of traditional flask culture, M96SS, Lukavský’s system, and a microplate shaker.

  8. Increased breast cancer screening and downstaging in Colombian women: A randomized trial of opportunistic breast-screening.

    Science.gov (United States)

    Murillo, Raúl; Díaz, Sandra; Perry, Fernando; Poveda, César; Piñeros, Marion; Sánchez, Oswaldo; Buitrago, Lina; Gamboa, Oscar; Lozano, Teófilo; Yu, Hsiang; Wang, Ching-Yun; Duggan, Catherine; Thomas, David B; Anderson, Benjamin O

    2016-02-01

    The lack of breast cancer screening in low and middle-income countries results in later stage diagnosis and worsened outcomes for women. A cluster randomized trial was performed in Bogotá, Colombia between 2008 and 2012 to evaluate effects of opportunistic breast cancer screening. Thirteen clinics were randomized to an intervention arm and 13 to a control arm. Physicians in intervention clinics were instructed to perform clinical breast examination on all women aged 50-69 years attending clinics for non-breast health issues, and then refer them for mammographic screening. Physicians in control clinics were not explicitly instructed to perform breast screening or mammography referrals, but could do so if they thought it indicated ("usual care"). Women were followed for 2-years postrandomization. 7,436 women were enrolled and 7,419 (99.8%) screened in intervention clinics, versus 8,419 enrolled and 1,108 (13.1%) screened in control clinics. Incidence ratios (IR) of early, advanced and all breast cancers were 2.9 (95% CI 1.1-9.2), 1.0 (0.3-3.5) and 1.9 (0.9-4.1) in the first (screening) year of the trial, and the cumulative IR for all breast cancers converged to 1.4 (0.7-2.8) by the end of follow-up (Year 2). Eighteen (69.2%) of 26 women with early stage disease had breast conservation surgery (BCS) versus 6 (42.5%) of 14 women with late-stage disease (p = 0.02). Fifteen (68.2%) of 22 women with breast cancer in the intervention group had BCS versus nine (50.0%) of 18 women in the control group (p = 0.34). Well-designed opportunistic clinic-based breast cancer screening programs may be useful for early breast cancer detection in LMICs. © 2015 The Authors. Published by Wiley Periodicals, Inc. on behalf of UICC.

  9. Can interface features affect aggression resulting from violent video game play? An examination of realistic controller and large screen size.

    Science.gov (United States)

    Kim, Ki Joon; Sundar, S Shyam

    2013-05-01

    Aggressiveness attributed to violent video game play is typically studied as a function of the content features of the game. However, can interface features of the game also affect aggression? Guided by the General Aggression Model (GAM), we examine the controller type (gun replica vs. mouse) and screen size (large vs. small) as key technological aspects that may affect the state aggression of gamers, with spatial presence and arousal as potential mediators. Results from a between-subjects experiment showed that a realistic controller and a large screen display induced greater aggression, presence, and arousal than a conventional mouse and a small screen display, respectively, and confirmed that trait aggression was a significant predictor of gamers' state aggression. Contrary to GAM, however, arousal showed no effects on aggression; instead, presence emerged as a significant mediator.

  10. A novel case-control design to estimate the extent of over-diagnosis of breast cancer due to organised population-based mammography screening.

    Science.gov (United States)

    Beckmann, Kerri R; Lynch, John W; Hiller, Janet E; Farshid, Gelareh; Houssami, Nehmat; Duffy, Stephen W; Roder, David M

    2015-03-15

    Debate about the extent of breast cancer over-diagnosis due to mammography screening has continued for over a decade, without consensus. Estimates range from 0 to 54%, but many studies have been criticized for having flawed methodology. In this study we used a novel study design to estimate over-diagnosis due to organised mammography screening in South Australia (SA). To estimate breast cancer incidence at and following screening we used a population-based, age-matched case-control design involving 4,931 breast cancer cases and 22,914 controls to obtain OR for yearly time intervals since women's last screening mammogram. The level of over-diagnosis was estimated by comparing the cumulative breast cancer incidence with and without screening. The former was derived by applying ORs for each time window to incidence rates in the absence of screening, and the latter, by projecting pre-screening incidence rates. Sensitivity analyses were undertaken to assess potential biases. Over-diagnosis was estimated to be 8% (95%CI 2-14%) and 14% (95%CI 8-19%) among SA women aged 45 to 85 years from 2006-2010, for invasive breast cancer and all breast cancer respectively. These estimates were robust when applying various sensitivity analyses, except for adjustment for potential confounding assuming higher risk among screened than non-screened women, which reduced levels of over-diagnosis to 1% (95%CI 5-7%) and 8% (95%CI 2-14%) respectively when incidence rates for screening participants were adjusted by 10%. Our results indicate that the level of over-diagnosis due to mammography screening is modest and considerably lower than many previous estimates, including others for Australia. © 2014 UICC.

  11. Inventions on GUI for Touch Sensitive Screens

    OpenAIRE

    Mishra, Umakant

    2014-01-01

    A touch sensitive screen displays the information on the screen and also receives the input by sensing a user's touch on the same screen. This mechanism facilitates system interaction directly through the screen without needing a mouse or keyboard. This method has the advantage to make the system compact by removing keyboard, mouse and similar interactive device. However there are certain difficulties to implement a touch screen interface. The display screens of portable devices are becoming ...

  12. New approaches to screening infrastructure investments in multi-reservoir systems- Evaluating proposed dams in Ethiopia and Kenya

    Science.gov (United States)

    Harou, J. J.; Geressu, R. T.; Hurford, A. P.

    2014-12-01

    Two approaches have been used traditionally to screen infrastructure investments in multi-reservoir systems: scenario analysis of a few simulated designs and deterministic optimization, sometimes using hydro-economic models or screening optimization models. Simulation models realistically represent proposed water systems and can easily include multiple performance metrics; however each prospective system operating rules need to be formulated and simulated for each proposed design (time consuming. Optimization models have been used to overcome this burden. Screening optimization models use integer or non-linear programming and can be challenging to apply to large and/or multi-objective systems. Hydro-economic models that use deterministic (implicit stochastic) optimization must be modified to examine each different plan and they cannot always reproduce realistic or politically acceptable system operations. In this presentation we demonstrate the application of a new screening approach to multi-reservoir systems where operating rules and new assets (dams) are simultaneously optimized in a multi-criteria context. Results are not least cost investment plans that satisfy reliability or other engineering constraints, but rather Pareto-optimal sets of asset portfolios that work well under historical and/or future scenarios. This is achieved by using stakeholder-built simulation models linked to multi-criteria search algorithms (e.g. many objective evolutionary algorithms, MOEA). Typical output is demonstrated through two case-studies on the Tana and Blue Nile rivers where operating rules and reservoir assets are efficiently screened together considering stakeholder-defined metrics. The focus on the Tana system is how reservoir operating rules and new irrigation schemes should be co-managed to limit ecological damages. On the Nile system, we identify Blue Nile river reservoir capacities that least negatively impact downstream Nile nations. Limitations and new directions of

  13. An Active Learning Classifier for Further Reducing Diabetic Retinopathy Screening System Cost

    Directory of Open Access Journals (Sweden)

    Yinan Zhang

    2016-01-01

    Full Text Available Diabetic retinopathy (DR screening system raises a financial problem. For further reducing DR screening cost, an active learning classifier is proposed in this paper. Our approach identifies retinal images based on features extracted by anatomical part recognition and lesion detection algorithms. Kernel extreme learning machine (KELM is a rapid classifier for solving classification problems in high dimensional space. Both active learning and ensemble technique elevate performance of KELM when using small training dataset. The committee only proposes necessary manual work to doctor for saving cost. On the publicly available Messidor database, our classifier is trained with 20%–35% of labeled retinal images and comparative classifiers are trained with 80% of labeled retinal images. Results show that our classifier can achieve better classification accuracy than Classification and Regression Tree, radial basis function SVM, Multilayer Perceptron SVM, Linear SVM, and K Nearest Neighbor. Empirical experiments suggest that our active learning classifier is efficient for further reducing DR screening cost.

  14. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  15. New screening system for unruptured cerebral aneurysms; Combination of an expert system and DSA examination

    Energy Technology Data Exchange (ETDEWEB)

    Samejima, Hirotsugu; Ushikubo, Yukio; Mizokami, Toru [Toho Univ., Tokyo (Japan). School of Medicine; and others

    1990-08-01

    We have designed a screening system to diagnose unruptured aneurysms, including the use of digital subtraction angiography (DSA). We surveyed 115 patients who had undergone clipping procedures after subarachnoid hemorrhage (SAH) and questioned them with regard to the subjective symptoms. Sixty-eight of 92 patients who returned the questionnaire reported, prior to rupture, headache,eye pain, and neck pain most frequently, and also impairment of extraocular movements, ptosis, visual field defects, and motor and sensory disturbances. Nineteen (47.5%) of 40 patients who had complete pain relief after surgery complained of headache from 1 week to 1 month before SAH. In addition, nine patients (22.5%) complained of headache for several years, and were also pain-free after surgery. For the indication of DSA, we employed an expert system based on fuzzy set theory. Seven groups of parameters are: Group 1, a basic questionnaire concerning age, sex, and past and family histories; Group 2, 15 warning signs selected on the basis of retrospective study; and Groups 3-7, detailed questions concerning each sign. Scoring weights assigned to each condition based on the results of the retrospective study, and threshold values were determined by several neurosurgeons. The certainty factors for intermediate hypotheses were calculated from these weights and threshold values and summed up, from which the conclusion was obtained. Twelve new cases of unruptured cerebral aneurysm were diagnosed using this screening system. This system may improve the ability to diagnose cerebral aneurysms before rupture. (author).

  16. 241-SY-101 DACS instrument problem screen (SCR 448) acceptance test procedure

    International Nuclear Information System (INIS)

    ERMI, A.M.

    1999-01-01

    The operability of the 241-SY-101 Data Acquisition and Control System (DACS) to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank utilizing the [INSTPROB] screen will be systematically evaluated by the performance of this procedure

  17. Efficacy of Allium cepa test system for screening cytotoxicity and genotoxicity of industrial effluents originated from different industrial activities.

    Science.gov (United States)

    Pathiratne, Asoka; Hemachandra, Chamini K; De Silva, Nimal

    2015-12-01

    Efficacy of Allium cepa test system for screening cytotoxicity and genotoxicity of treated effluents originated from four types of industrial activities (two textile industries, three rubber based industries, two common treatment plants of industrial zones, and two water treatment plants) was assessed. Physico-chemical parameters including the heavy metal/metalloid levels of the effluents varied depending on the industry profile, but most of the measured parameters in the effluents were within the specified tolerance limits of Sri Lankan environmental regulations for discharge of industrial effluents into inland surface waters. In the A. cepa test system, the undiluted effluents induced statistically significant root growth retardation, mitosis depression, and chromosomal aberrations in root meristematic cells in most cases in comparison to the dilution water and upstream water signifying effluent induced cytotoxicity and genotoxicity. Ethyl methane sulphonate (a mutagen, positive control) and all the effluents under 1:8 dilution significantly induced total chromosomal aberrations in root meristematic cells in comparison to the dilution water and upstream water indicating inadequacy of expected 1:8 dilutions in the receiving waters for curtailing genotoxic impacts. The results support the use of a practically feasible A. cepa test system for rapid screening of cytotoxicity and genotoxicity of diverse industrial effluents discharging into inland surface waters.

  18. Computer control of the high-voltage power supply for the DIII-D electron cyclotron heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1992-01-01

    This paper reports on the DIII-D Electron Cyclotron Heating (ECH) high voltage power supply which is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interfact is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished; physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplies, each with its own database, through a single computer console

  19. Screening of pollution control and clean-up materials for river chemical spills using the multiple case-based reasoning method with a difference-driven revision strategy.

    Science.gov (United States)

    Liu, Rentao; Jiang, Jiping; Guo, Liang; Shi, Bin; Liu, Jie; Du, Zhaolin; Wang, Peng

    2016-06-01

    In-depth filtering of emergency disposal technology (EDT) and materials has been required in the process of environmental pollution emergency disposal. However, an urgent problem that must be solved is how to quickly and accurately select the most appropriate materials for treating a pollution event from the existing spill control and clean-up materials (SCCM). To meet this need, the following objectives were addressed in this study. First, the material base and a case base for environment pollution emergency disposal were established to build a foundation and provide material for SCCM screening. Second, the multiple case-based reasoning model method with a difference-driven revision strategy (DDRS-MCBR) was applied to improve the original dual case-based reasoning model method system, and screening and decision-making was performed for SCCM using this model. Third, an actual environmental pollution accident from 2012 was used as a case study to verify the material base, case base, and screening model. The results demonstrated that the DDRS-MCBR method was fast, efficient, and practical. The DDRS-MCBR method changes the passive situation in which the choice of SCCM screening depends only on the subjective experience of the decision maker and offers a new approach to screening SCCM.

  20. Essential attributes identified in the design of a Laboratory Information Management System for a high throughput siRNA screening laboratory.

    Science.gov (United States)

    Grandjean, Geoffrey; Graham, Ryan; Bartholomeusz, Geoffrey

    2011-11-01

    In recent years high throughput screening operations have become a critical application in functional and translational research. Although a seemingly unmanageable amount of data is generated by these high-throughput, large-scale techniques, through careful planning, an effective Laboratory Information Management System (LIMS) can be developed and implemented in order to streamline all phases of a workflow. Just as important as data mining and analysis procedures at the end of complex processes is the tracking of individual steps of applications that generate such data. Ultimately, the use of a customized LIMS will enable users to extract meaningful results from large datasets while trusting the robustness of their assays. To illustrate the design of a custom LIMS, this practical example is provided to highlight the important aspects of the design of a LIMS to effectively modulate all aspects of an siRNA screening service. This system incorporates inventory management, control of workflow, data handling and interaction with investigators, statisticians and administrators. All these modules are regulated in a synchronous manner within the LIMS. © 2011 Bentham Science Publishers

  1. Imaging characteristics of different mammographic screens.

    Science.gov (United States)

    Kuhn, H; Knüpfer, W

    1992-01-01

    A study of mammography systems with green-emitting screens was conducted to determine how the image quality parameters (apart from dose requirement), such as modulation transfer function (MTF) and Wiener spectrum (WS), depend on the dye content of the compound and coating weight of the screen. In addition, the contribution to total noise of the individual components, i.e., film, screen, and quantum noise, was studied. The quantities derived from MTF and WS, namely detective quantum efficiency (DQE) and noise equivalent quanta (NEQ), were also investigated in regard to their dose dependency. It can be demonstrated that the MTF of the screens becomes more favorable when the dye content is increased, while noise is not significantly affected. This suggests the use of a mammography screen capable of greater detail recognition, requiring at least double the dose of today's conventional systems with approximately 80 microGy system dose. On the other hand, the manufacture of a screen with about 60% of the dose of the conventional system is possible with very little loss in image quality. For the systems in common use today (80 microGy), quantum noise represents a considerable share of the total noise at low spatial frequencies, whereas in high spatial frequencies, the graininess of the film dominates quantum noise and screen structure.

  2. 20 CFR 654.408 - Screening.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Screening. 654.408 Section 654.408 Employees... EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.408 Screening. (a) All outside openings shall be protected with screening of not less than 16 mesh. (b) All screen doors shall be...

  3. Control system design method

    Science.gov (United States)

    Wilson, David G [Tijeras, NM; Robinett, III, Rush D.

    2012-02-21

    A control system design method and concomitant control system comprising representing a physical apparatus to be controlled as a Hamiltonian system, determining elements of the Hamiltonian system representation which are power generators, power dissipators, and power storage devices, analyzing stability and performance of the Hamiltonian system based on the results of the determining step and determining necessary and sufficient conditions for stability of the Hamiltonian system, creating a stable control system based on the results of the analyzing step, and employing the resulting control system to control the physical apparatus.

  4. Silver-embedded screens in the intensive care unit. A new tool to control multi-drug resistant bacterial cross-transmission.

    Science.gov (United States)

    Ruiz, J; Ramirez, P; Villarreal, E; Gordon, M; Cuesta, S; Piñol, M; Frasquet, J; Castellanos, Á

    2017-08-01

    The purpose of this study was to assess the effectiveness of silver-embedded surfaces (BactiBlock®) to prevent surface colonization by multi-resistant bacteria (MRB) and to reduce the incidence of MRB colonization and infection in patients admitted to an intensive care unit (ICU). A 6-month prospective observational study in a 24-bed mixed ICU divided into two identical subunits (12 beds each) was designed. Seven solid mobile screens were placed in one of the subunits while in the other cloth screens remained. Solid screens were constructed with high-density polyethylene embedded in Bactiblock®. To evaluate the effectiveness of screens coated with Bactiblock®, number of MRB isolates on screens were compared for 6 months. Likewise, numbers of new patients and ICU-stays with MRB colonization in the two subunits were compared. One hundred forty screen samples were collected in 10-point prevalent days. MRB were detected on 28 (20.0%) samples. Over the 70 samples taken on cloth folding screens, MRB were detected in 25 (35.7%), while only 3 (4.3%) of the 70 samples taken on Bactiblock® screens were positive for MRB (p unit with Bactiblock® screens presented fewer number of ICU stays with MRB colonization (27.8% vs 47.1%; p units, proving to be an useful tool in the control of MRB.

  5. Gender Identity Disparities in Cancer Screening Behaviors.

    Science.gov (United States)

    Tabaac, Ariella R; Sutter, Megan E; Wall, Catherine S J; Baker, Kellan E

    2018-03-01

    Transgender (trans) and gender-nonconforming adults have reported reduced access to health care because of discrimination and lack of knowledgeable care. This study aimed to contribute to the nascent cancer prevention literature among trans and gender-nonconforming individuals by ascertaining rates of breast, cervical, prostate, and colorectal cancer screening behaviors by gender identity. Publicly available de-identified data from the 2014-2016 Behavioral Risk Factor Surveillance System surveys were utilized to evaluate rates of cancer screenings by gender identity, while controlling for healthcare access, sociodemographics, and survey year. Analyses were conducted in 2017. Weighted chi-square tests identified significant differences in the proportion of cancer screening behaviors by gender identity among lifetime colorectal cancer screenings, Pap tests, prostate-specific antigen tests, discussing prostate-specific antigen test advantages/disadvantages with their healthcare provider, and up-to-date colorectal cancer screenings and Pap tests (pgender identity were fully explained by covariates, trans women had reduced odds of having up-to-date colorectal cancer screenings compared to cisgender (cis) men (AOR=0.20) and cis women (AOR=0.24), whereas trans men were more likely to ever receive a sigmoidoscopy/colonoscopy as compared to cis men (AOR=2.76) and cis women (AOR=2.65). Trans women were more likely than cis men to have up-to-date prostate-specific antigen tests (AOR=3.19). Finally, trans men and gender-nonconforming individuals had reduced odds of lifetime Pap tests versus cis women (AOR=0.14 and 0.08, respectively), and gender-nonconforming individuals had lower odds of discussing prostate-specific antigen tests than cis men (AOR=0.09; all pgender identity disparities in cancer screenings persist beyond known sociodemographic and healthcare factors. It is critical that gender identity questions are included in cancer and other health-related surveillance

  6. An Auto-Tuning PI Control System for an Open-Circuit Low-Speed Wind Tunnel Designed for Greenhouse Technology.

    Science.gov (United States)

    Espinoza, Karlos; Valera, Diego L; Torres, José A; López, Alejandro; Molina-Aiz, Francisco D

    2015-08-12

    Wind tunnels are a key experimental tool for the analysis of airflow parameters in many fields of application. Despite their great potential impact on agricultural research, few contributions have dealt with the development of automatic control systems for wind tunnels in the field of greenhouse technology. The objective of this paper is to present an automatic control system that provides precision and speed of measurement, as well as efficient data processing in low-speed wind tunnel experiments for greenhouse engineering applications. The system is based on an algorithm that identifies the system model and calculates the optimum PI controller. The validation of the system was performed on a cellulose evaporative cooling pad and on insect-proof screens to assess its response to perturbations. The control system provided an accuracy of integrated software unit that manages the tests in terms of airflow speed and pressure drop set points.

  7. New, Improved Version of the mCOP-PCR Screening System for Detection of Spinal Muscular Atrophy Gene (SMN1) Deletion.

    Science.gov (United States)

    Shinohara, Masakazu; Ar Rochmah, Mawaddah; Nakanishi, Kenta; Harahap, Nur Imma Fatimah; Niba, Emma Tabe Eko; Saito, Toshio; Saito, Kayoko; Takeuchi, Atsuko; Bouike, Yoshihiro; Nishio, Hisahide

    2017-09-07

    Spinal muscular atrophy (SMA) is a frequent autosomal recessive disorder, characterized by lower motor neuron loss in the spinal cord. More than 95% of SMA patients show homozygous survival motor neuron 1 (SMN1) deletion. We previously developed a screening system for SMN1 deletion based on a modified competitive oligonucleotide priming-PCR (mCOP-PCR) technique. However, non-specific amplification products were observed with mCOP-PCR, which might lead to erroneous interpretation of the screening results. To establish an improved version of the mCOP-PCR screening system without non-specific amplification. DNA samples were assayed using a new version of the mCOP-PCR screening system. DNA samples had already been genotyped by PCR-restriction fragment length polymorphism (PCR-RFLP), showing the presence or absence of SMN1 exon 7. The new mCOP-PCR method contained a targeted pre-amplification step of the region, including an SMN1-specific nucleotide, prior to the mCOP-PCR step. mCOP-PCR products were electrophoresed on agarose gels. No non-specific amplification products were detected in electrophoresis gels with the new mCOP-PCR screening system. An additional targeted pre-amplification step eliminated non-specific amplification from mCOP-PCR screening.

  8. Incoherent control of locally controllable quantum systems

    International Nuclear Information System (INIS)

    Dong Daoyi; Zhang Chenbin; Rabitz, Herschel; Pechen, Alexander; Tarn, T.-J.

    2008-01-01

    An incoherent control scheme for state control of locally controllable quantum systems is proposed. This scheme includes three steps: (1) amplitude amplification of the initial state by a suitable unitary transformation, (2) projective measurement of the amplified state, and (3) final optimization by a unitary controlled transformation. The first step increases the amplitudes of some desired eigenstates and the corresponding probability of observing these eigenstates, the second step projects, with high probability, the amplified state into a desired eigenstate, and the last step steers this eigenstate into the target state. Within this scheme, two control algorithms are presented for two classes of quantum systems. As an example, the incoherent control scheme is applied to the control of a hydrogen atom by an external field. The results support the suggestion that projective measurements can serve as an effective control and local controllability information can be used to design control laws for quantum systems. Thus, this scheme establishes a subtle connection between control design and controllability analysis of quantum systems and provides an effective engineering approach in controlling quantum systems with partial controllability information.

  9. The ParaDNA® Screening System - a case study in bringing forensic R&D to market.

    Science.gov (United States)

    Dawnay, Nick; Ahmed, Romana; Naif, Sarah

    2014-12-01

    The creation of new technologies and their application to forensic science is key to the field's development. Rapid DNA profiling is one such area of research which has grown in response to a desire from enforcement authorities for in-house forensic DNA processing and rapid access to forensic genetic intelligence. However, introducing novel technologies into the forensics market must be carefully monitored and controlled as the success or failure of any technology ultimately has long standing implications for victims, suspects, and also to Police and forensic practitioners. This article outlines the research, development, validation and implementation of the ParaDNA® Screening System as a case study in taking forensic research and development to market. Copyright © 2014. Published by Elsevier Ireland Ltd.

  10. Comparison of average glandular dose in screen-film and digital mammography using breast tissue-equivalent phantom

    International Nuclear Information System (INIS)

    Shin, Gwi Soon; Kim, Jung Min; Kim, You Hyun; Choi, Jong Hak; Kim, Chang Kyun

    2007-01-01

    In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate (IP). We measured average glandular doses (ADG) in screen-film mammography (SFM) system with slow screen-film combination, computed mammography (CM) system, indirect digital mammography (IDM) system and direct digital mammography (DDM) system using breast tissue-equivalent phantom (glandularity 30%, 50% and 70%). The results were shown as follows: AGD values for DDM system were highest than those for other systems. Although automatic exposure control (AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter (Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in order to estimate a patient radiation dose

  11. Control systems engineering

    CERN Document Server

    Nise, Norman S

    1995-01-01

    This completely updated new edition shows how to use MATLAB to perform control-system calculations. Designed for the professional or engineering student who needs a quick and readable update on designing control systems, the text features a series of tightly focused examples that clearly illustrate each concept of designing control systems. Most chapters conclude with a detailed application from the two case studies that run throughout the book: an antenna asimuth control system and a submarine. The author also refers to many examples of design methods.

  12. Discrete control systems

    CERN Document Server

    Okuyama, Yoshifumi

    2014-01-01

    Discrete Control Systems establishes a basis for the analysis and design of discretized/quantized control systemsfor continuous physical systems. Beginning with the necessary mathematical foundations and system-model descriptions, the text moves on to derive a robust stability condition. To keep a practical perspective on the uncertain physical systems considered, most of the methods treated are carried out in the frequency domain. As part of the design procedure, modified Nyquist–Hall and Nichols diagrams are presented and discretized proportional–integral–derivative control schemes are reconsidered. Schemes for model-reference feedback and discrete-type observers are proposed. Although single-loop feedback systems form the core of the text, some consideration is given to multiple loops and nonlinearities. The robust control performance and stability of interval systems (with multiple uncertainties) are outlined. Finally, the monograph describes the relationship between feedback-control and discrete ev...

  13. Shared decision making for prostate cancer screening: the results of a combined analysis of two practice-based randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Sheridan Stacey L

    2012-11-01

    Full Text Available Abstract Background Professional societies recommend shared decision making (SDM for prostate cancer screening, however, most efforts have promoted informed rather than shared decision making. The objective of this study is to 1 examine the effects of a prostate cancer screening intervention to promote SDM and 2 determine whether framing prostate information in the context of other clearly beneficial men’s health services affects decisions. Methods We conducted two separate randomized controlled trials of the same prostate cancer intervention (with or without additional information on more clearly beneficial men’s health services. For each trial, we enrolled a convenience sample of 2 internal medicine practices, and their interested physicians and male patients with no prior history of prostate cancer (for a total of 4 practices, 28 physicians, and 128 men across trials. Within each practice site, we randomized men to either 1 a video-based decision aid and researcher-led coaching session or 2 a highway safety video. Physicians at each site received a 1-hour educational session on prostate cancer and SDM. To assess intervention effects, we measured key components of SDM, intent to be screened, and actual screening. After finding that results did not vary by trial, we combined data across sites, adjusting for the random effects of both practice and physician. Results Compared to an attention control, our prostate cancer screening intervention increased men’s perceptions that screening is a decision (absolute difference +41%; 95% CI 25 to 57% and men’s knowledge about prostate cancer screening (absolute difference +34%; 95% CI 19% to 50%, but had no effect on men’s self-reported participation in shared decisions or their participation at their preferred level. Overall, the intervention decreased screening intent (absolute difference −34%; 95% CI −50% to −18% and actual screening rates (absolute difference −22%; 95% CI −38 to

  14. Quantitative safety assessment of air traffic control systems through system control capacity

    Science.gov (United States)

    Guo, Jingjing

    Quantitative Safety Assessments (QSA) are essential to safety benefit verification and regulations of developmental changes in safety critical systems like the Air Traffic Control (ATC) systems. Effectiveness of the assessments is particularly desirable today in the safe implementations of revolutionary ATC overhauls like NextGen and SESAR. QSA of ATC systems are however challenged by system complexity and lack of accident data. Extending from the idea "safety is a control problem" in the literature, this research proposes to assess system safety from the control perspective, through quantifying a system's "control capacity". A system's safety performance correlates to this "control capacity" in the control of "safety critical processes". To examine this idea in QSA of the ATC systems, a Control-capacity Based Safety Assessment Framework (CBSAF) is developed which includes two control capacity metrics and a procedural method. The two metrics are Probabilistic System Control-capacity (PSC) and Temporal System Control-capacity (TSC); each addresses an aspect of a system's control capacity. And the procedural method consists three general stages: I) identification of safety critical processes, II) development of system control models and III) evaluation of system control capacity. The CBSAF was tested in two case studies. The first one assesses an en-route collision avoidance scenario and compares three hypothetical configurations. The CBSAF was able to capture the uncoordinated behavior between two means of control, as was observed in a historic midair collision accident. The second case study compares CBSAF with an existing risk based QSA method in assessing the safety benefits of introducing a runway incursion alert system. Similar conclusions are reached between the two methods, while the CBSAF has the advantage of simplicity and provides a new control-based perspective and interpretation to the assessments. The case studies are intended to investigate the

  15. Design and Application of SCADA Based Control System for filling process (Inter facing and Monitoring)

    International Nuclear Information System (INIS)

    Aung Naing Myint; Maung Maung Latt; Win Khaing Moe; Theingi

    2008-06-01

    In a small SCADA system, using industrial standard components and simulating real world applications, designs and constructs for thesis to interface between automation devices and software. It programs PIC microcontroller that need the information to write the sequence of process that flowchart like the PIC ladder-logic programs that control the equipment in system, software integrators to be required the information for the configuration screens and hardware installers which need the information to install and connect the equipment. It uses the initiating processor's multiplexer to verify that data or signals are being transmitted out of the parallel port and includes auto-coupler to divide different voltages between circuits and computer. Existing SCADA system are divisible into two groups - cheap and inflexible control, and another one is expensive but flexible control. This thesis attempted by means of using other network for SCADA communications and simple for control, both of which maintain flexibility while reducing cost

  16. Loss and benefit of DR system in mass screening for upper GI-tracts. Comparison with an II-TV based DR system and 100-mm roll-film system

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Fujita, Hiroshi.

    1995-01-01

    A 2048 x 2048 matrix II-TV based digital radiography (DR) system, a fully digital imaging system with diagnosis on the CRT monitor, had been introduced to Cancer Institute Hospital for the GI-tracts examinations since January 1990. Furthermore, we had applied it to the mass screening of upper GI-tract since November 1992. In the present study, a retrospective study on clinical evaluation and features of the DR system for the mass screening were investigated and compared with the screening data taken by conventional 100-mm roll-film technique in the previous year. The loss ratios and appearance of the mucosal patterns in upper gastric images were studied as well. Also determined was the reading time of those images in the mass screening situation. It was found that the loss ratio on the subject image information in 100-mm roll-film images was smaller than that in DR images. However, the DR images processed by windowing technique provided the perfect information without partially over or under density area. It was shown that the clinical image quality greatly depended on the radiographic technique by radiologists or technologists rather than on the imaging modality itself employed; even in II/TV-DR system, the radiographic technique is important. Because of some issues, including the size of CRT monitor, eyestrain for CRT monitor, and windowing operation regard to reading system, the reading time of CRT images was 1.44-2.05 times longer than that of 100-mm roll-film images. (author)

  17. A versatile and light-weight slow control system for small-scale applications

    Science.gov (United States)

    Zappa, P.; Bütikofer, L.; Coderre, D.; Kaminsky, B.; Schumann, M.; von Sivers, M.

    2016-09-01

    We present an open source slow control system for small and medium scale projects. Thanks to its modular and flexible design, where the various instruments are read and controlled by independent plugins, Doberman (Detector OBsERving and Monitoring ApplicatioN) can be quickly adapted for many applications, also making use of existing code or proprietary components. The system uses a SQL database to store the data from the instruments and provides an online application to display and browse through the data. It allows the modification of device settings while the program is running and features a protocol to handle exceptions, including the automated distribution of alarm messages. We present two case studies from astroparticle physics, on which Doberman is successfully deployed: a low-background screening facility installed in a remote underground laboratory and a detector R&D platform using cryogenic liquid xenon.

  18. Internet-Based Cervical Cytology Screening System

    National Research Council Canada - National Science Library

    Wilbur, David C; Crothers, Barbara A; Eichhorn, John H; Ro, Min S; Gelfand, Jeffrey A

    2007-01-01

    This project explores the combination of computerized automated primary screening of cervical cytology specimens in remote sites with interpretation of device-selected images transmitted via the Internet...

  19. Increasing Cervical Cancer Screening Coverage: A Randomised, Community-Based Clinical Trial.

    Directory of Open Access Journals (Sweden)

    Amelia Acera

    Full Text Available Opportunistic cervical cancer screening can lead to suboptimal screening coverage. Coverage could be increased after a personalised invitation to the target population. We present a community randomized intervention study with three strategies aiming to increase screening coverage.The CRICERVA study is a community-based clinical trial to improve coverage of population-based screening in the Cerdanyola SAP area in Barcelona.A total of 32,858 women residing in the study area, aged 30 to 70 years were evaluated. A total of 15,965 women were identified as having no registration of a cervical cytology in the last 3.5 years within the Public Health data base system. Eligible women were assigned to one of four community randomized intervention groups (IGs: (1 (IG1 N = 4197 personalised invitation letter, (2 (IG2 N = 3601 personalised invitation letter + informative leaflet, (3 (IG3 N = 6088 personalised invitation letter + informative leaflet + personalised phone call and (4 (Control N = 2079 based on spontaneous demand of cervical cancer screening as officially recommended. To evaluate screening coverage, we used heterogeneity tests to compare impact of the interventions and mixed logistic regression models to assess the age effect. We refer a "rescue" visit as the screening visit resulting from the study invitation.Among the 13,886 women in the IGs, 2,862 were evaluated as having an adequate screening history after the initial contact; 4,263 were lost to follow-up and 5,341 were identified as having insufficient screening and thus being eligible for a rescue visit. All intervention strategies significantly increased participation to screening compared to the control group. Coverage after the intervention reached 84.1% while the control group reached 64.8%. The final impact of our study was an increase of 20% in the three IGs and of 9% in the control group (p<0.001. Within the intervention arms, age was an important determinant of rescue visits

  20. Vascular injury outcomes with screening implementation

    Directory of Open Access Journals (Sweden)

    James D. Weinberg, MD

    2017-09-01

    Full Text Available Blunt carotid and vertebral artery injuries (BCVI are generally viewed as rare events. Screening guidelines based on the Memphis and Denver data were put into place at Palmetto Health Richland in August of 2008. This study aims to look at the incidence of BCVI 2 years before the guidelines were put into place and then 2 years after. A total of 11,005 trauma patients presented during our study period. 98 patients were determined to have BCVI and met inclusion criteria: 21 in the Control group and 77 in the Screening group. A total of 16 deaths and 14 strokes were recorded in the study population. The odds of patients in the Screening group dying were 29% lower than that of a patient in the Control group [OR: 0.71, (95% CI: 0.20–2.50; p = 0.59], after adjusting for ISS. The odds of developing a stroke in the Screening group were 69% lower than the Control group [OR: 0.31 (0.09–1.08; p = 0.067]. These differences were not statistically significant. The increased BCVI incidence rate and decreased stroke and mortality rate following screening implementation further support the importance of having screening criteria for blunt vascular injury following trauma.

  1. Comparison of low-contrast detectability of computed radiography and screen/ film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan-Hoong Ng; McLean, D.; McLean, D.

    2008-01-01

    The objective of this study is to compare low-contrast detectability of computed radiography (CR) and screen/ film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low-contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significance of the difference in contrast between CR and SF, and for each exposure parameter, was tested using non-parametric Kruskal-Wallis test. The low-contrast detectability of the CR (soft copy and hard copy) system was found to be not significantly different to that of the SF system (p> 0.05, Kruskal-Wallis test).For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low-contrast objects such as small low-contrast areas corresponding to breast pathology. (Author)

  2. Development of a home screening system for pediatric respiratory sleep studies.

    Science.gov (United States)

    Foo, Jong Yong Abdiel; Lim, Chu Sing

    2006-12-01

    To develop a simple and portable home screening monitor for sleep-disordered breathing (SDB) in children. In such a system, identifying the respiratory events and occurrences of motional artifacts are two essential elements that can affect the accuracy of the study. Moreover, such a system needs to be easy to set up and user friendly. The proposed system includes the following: electrocardiogram, pulse oximeter, microcontroller-based computation device, and a tri-axial accelerometer. Three physiologic parameters derived with this device were used to identify central (CE) and obstructive (OE) respiratory events. The criteria used were based on documented evidence and compared against corresponding standard polysomnographic scorings. In addition, a module was constructed in conjunction with a RS232 chip to transmit the recorded data to a personal computer. The accelerometer was used as a motion artifact detector. Detectable signals were acquired from the accelerometer when artifacts were induced on the photoplethysmography by motions in three regulated test activities lasting at least 30 seconds each. In classifying respiratory events, the combined use of oxygen saturation, heart rate, and pulse transit time to produce a complex classification (logic OR) showed promise. For OE, the sensitivity and specificity were 0.828 and 0.859, respectively. For CE, these values were 0.868 and 0.762, respectively. The proposed system potentially fulfils the criterion as a home screening tool and can form an indispensable addition to the SDB investigation in the pediatric population.

  3. Colometer: a real-time quality feedback system for screening colonoscopy.

    Science.gov (United States)

    Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N

    2012-08-28

    To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3

  4. 3D X-Ray Luggage-Screening System

    Science.gov (United States)

    Fernandez, Kenneth

    2006-01-01

    A three-dimensional (3D) x-ray luggage- screening system has been proposed to reduce the fatigue experienced by human inspectors and increase their ability to detect weapons and other contraband. The system and variants thereof could supplant thousands of xray scanners now in use at hundreds of airports in the United States and other countries. The device would be applicable to any security checkpoint application where current two-dimensional scanners are in use. A conventional x-ray luggage scanner generates a single two-dimensional (2D) image that conveys no depth information. Therefore, a human inspector must scrutinize the image in an effort to understand ambiguous-appearing objects as they pass by at high speed on a conveyor belt. Such a high level of concentration can induce fatigue, causing the inspector to reduce concentration and vigilance. In addition, because of the lack of depth information, contraband objects could be made more difficult to detect by positioning them near other objects so as to create x-ray images that confuse inspectors. The proposed system would make it unnecessary for a human inspector to interpret 2D images, which show objects at different depths as superimposed. Instead, the system would take advantage of the natural human ability to infer 3D information from stereographic or stereoscopic images. The inspector would be able to perceive two objects at different depths, in a more nearly natural manner, as distinct 3D objects lying at different depths. Hence, the inspector could recognize objects with greater accuracy and less effort. The major components of the proposed system would be similar to those of x-ray luggage scanners now in use. As in a conventional x-ray scanner, there would be an x-ray source. Unlike in a conventional scanner, there would be two x-ray image sensors, denoted the left and right sensors, located at positions along the conveyor that are upstream and downstream, respectively (see figure). X-ray illumination

  5. The Lung Screen Uptake Trial (LSUT): protocol for a randomised controlled demonstration lung cancer screening pilot testing a targeted invitation strategy for high risk and 'hard-to-reach' patients.

    Science.gov (United States)

    Quaife, Samantha L; Ruparel, Mamta; Beeken, Rebecca J; McEwen, Andy; Isitt, John; Nolan, Gary; Sennett, Karen; Baldwin, David R; Duffy, Stephen W; Janes, Samuel M; Wardle, Jane

    2016-04-20

    Participation in low-dose CT (LDCT) lung cancer screening offered in the trial context has been poor, especially among smokers from socioeconomically deprived backgrounds; a group for whom the risk-benefit ratio is improved due to their high risk of lung cancer. Attracting high risk participants is essential to the success and equity of any future screening programme. This study will investigate whether the observed low and biased uptake of screening can be improved using a targeted invitation strategy. A randomised controlled trial design will be used to test whether targeted invitation materials are effective at improving engagement with an offer of lung cancer screening for high risk candidates. Two thousand patients aged 60-75 and recorded as a smoker within the last five years by their GP, will be identified from primary care records and individually randomised to receive either intervention invitation materials (which take a targeted, stepped and low burden approach to information provision prior to the appointment) or control invitation materials. The primary outcome is uptake of a nurse-led 'lung health check' hospital appointment, during which patients will be offered a spirometry test, an exhaled carbon monoxide (CO) reading, and an LDCT if eligible. Initial data on demographics (i.e. age, sex, ethnicity, deprivation score) and smoking status will be collected in primary care and analysed to explore differences between attenders and non-attenders with respect to invitation group. Those who attend the lung health check will have further data on smoking collected during their appointment (including pack-year history, nicotine dependence and confidence to quit). Secondary outcomes will include willingness to be screened, uptake of LDCT and measures of informed decision-making to ensure the latter is not compromised by either invitation strategy. If effective at improving informed uptake of screening and reducing bias in participation, this invitation

  6. Effectiveness and costeffectiveness of screening immigrants ...

    African Journals Online (AJOL)

    Background: Immigrants to developed countries are a major source of TB. Therefore amongst strategies adopted for TB control in developed countries include; 1) Screening immigrants at ports of entry referred to as “Port of Arrival Screening” (PoA) and 2) Passive screening (PS) for TB which means screening immigrants ...

  7. Evaluation of functional color vision requirements and current color vision screening tests for air traffic control specialists.

    Science.gov (United States)

    1990-08-01

    An experiment was conducted to evaluate the relation of type and degree of color vision deficiency and aeromedical color vision screening test scores to performance of color-dependent tasks of Air Traffic Control Specialists. The subjects included 37...

  8. Minicomputer controlled test system for process control and monitoring systems

    International Nuclear Information System (INIS)

    Worster, L.D.

    A minicomputer controlled test system for testing process control and monitoring systems is described. This system, in service for over one year, has demonstrated that computerized control of such testing has a real potential for expanding the scope of the testing, improving accuracy of testing, and significantly reducing the time required to do the testing. The test system is built around a 16-bit minicomputer with 12K of memory. The system programming language is BASIC with the addition of assembly level routines for communication with the peripheral devices. The peripheral devices include a 100 channel scanner, analog-to-digital converter, visual display, and strip printer. (auth)

  9. Screening report : Municipality of Leamington : Leamington Pollution Control Centre stand-by emergency power class environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-03-15

    The Leamington Pollution Control Centre (PCC) is located in Ontario and treats residential and commercial wastewater collected from the Municipality of Leamington. The Leamington PCC currently has one standby diesel generator with a rated capacity of 545 kW. This generator provides power to the plant's disinfection facilities to reduce the risk of back-up into the collection system during power failures. The Municipality of Leamington plans to provide treatment in addition to disinfection during power outages. In order to achieve this, additional standby power is required to run the primary clarifiers, the aeration system and the secondary clarifiers. This document presented a screening report for the new standby generator, whose installation is considered a Schedule B under the Municipal Class Environmental Assessment process. The report reviewed background information on the proposed project; Ontario's Environmental Assessment Act; and the Class Environmental Assessment Act. It outlined the problem statement; identification of solutions; existing conditions; impacts and mitigation during construction and operation; and public consultation procedures. 2 refs., 4 figs., 1 appendix.

  10. Intelligent plasma operation and control system for HL-2M

    International Nuclear Information System (INIS)

    Xia, F.; Chen, L.Y.; Wang, C.; Zhang, G.; Song, X.M.; Song, X.; Pan, L.; Zhao, L.; Pan, W.; Lan, J.T.

    2015-01-01

    Full text of publication follows. The Intelligent Plasma Operation and Control System (IPOCS) for HL-2M is under construction based on the current actual situation of HL-2A control system in SWIP. The purpose of IPOCS is to replace the routine processes before, during and post discharge with the automatic process algorithms and give various information, for example, status, warning, reason, instruction, suggestion, physics phenomenon etc. to staff who can access the intranet. In this case, the core research objectives can be focused on and the related operations can be carried out referring to the information. The ultimate goal of IPOCS is to improve the efficiency of plant operation and control and physics research for HL-2M and for the fusion reactor in the future. There are three layers in IPOCS, which are named the information collection layer, the data processing layer and the presentation layer respectively. Information collection layer consists of data acquisition system, EPICS system, Audio and Video system, discharge scheduling system, data storage system etc. All raw data are collected and stored in this layer. The data processing layer is the core of IPOCS. Most algorithms are executed here. The basic computation platform is based on cluster (56 cores at present) and Parallel Computing Toolbox provided by Matlab. The physics database for SWIP based on HDF5 and offline EFIT also locate at this layer. All the operations can be finished during the time interval between two shots. The last layer is to present the information from the former two layers. The typical hardware including the large display screen system in the control room, the voice broadcasting system, personal monitors and smart phones, etc.. Several applications has being developed such as Control System Studio (CSS) in SWIP version, WebOPI, Automatic Alarm Display system and so on. IPOCS for HL-2M is at the very beginning phase at present. With more and more systems and algorithms got

  11. The yeast two hybrid system in a screen for proteins interacting with axolotl (Ambystoma mexicanum) Msx1 during early limb regeneration.

    Science.gov (United States)

    Abuqarn, Mehtap; Allmeling, Christina; Amshoff, Inga; Menger, Bjoern; Nasser, Inas; Vogt, Peter M; Reimers, Kerstin

    2011-07-01

    Urodele amphibians are exceptional in their ability to regenerate complex body structures such as limbs. Limb regeneration depends on a process called dedifferentiation. Under an inductive wound epidermis terminally differentiated cells transform to pluripotent progenitor cells that coordinately proliferate and eventually redifferentiate to form the new appendage. Recent studies have developed molecular models integrating a set of genes that might have important functions in the control of regenerative cellular plasticity. Among them is Msx1, which induced dedifferentiation in mammalian myotubes in vitro. Herein, we screened for interaction partners of axolotl Msx1 using a yeast two hybrid system. A two hybrid cDNA library of 5-day-old wound epidermis and underlying tissue containing more than 2×10⁶ cDNAs was constructed and used in the screen. 34 resulting cDNA clones were isolated and sequenced. We then compared sequences of the isolated clones to annotated EST contigs of the Salamander EST database (BLASTn) to identify presumptive orthologs. We subsequently searched all no-hit clone sequences against non redundant NCBI sequence databases using BLASTx. It is the first time, that the yeast two hybrid system was adapted to the axolotl animal model and successfully used in a screen for proteins interacting with Msx1 in the context of amphibian limb regeneration. 2011 Elsevier B.V. All rights reserved.

  12. FPGA based control system for -100 kV, 25 A Crowbarless DC power supply

    International Nuclear Information System (INIS)

    Upadhyay, R.; Tripathi, A.; Badapanda, M.K.; Lad, M.

    2015-01-01

    FPGA based digital control system has been developed for -100 kV, 25 A solid state modular crowbarless DC klystron bias power supply of 1 MW, 352.2 MHz RF test stand. The control system has capability to operate this power supply either in CW or pulse mode. Central controller, PSM controller and graphical user interface are key parts of this control system. Central controller monitors the status of various subsystems of this power supply like 11 kV step start unit, four numbers of main transformers each having 44 numbers of secondary windings and 176 numbers of switch power modules for deciding the number of power modules to be put ON and their duty cycles depending on the set output voltage and current. PSM controller sends appropriate control signal to the switch power modules through fibre optic lines and communicates it to the central controller. Linux based graphical user interface has been developed which enables the user to set the operating parameters along with their trip limits and displays the information of critical parameters of this power supply on a local touch screen panel. Provision for remote control and supervision is also provided through a separate PC connected to the main control system via Ethernet. The control system has capability to trip the power supply within 5 μsec in case any parameter exceeds its set limit. Suitable data logging feature is incorporated for offline fault analysis. The control system architecture along with its software protection interlocks are presented in this paper. The performance of the control system has been verified during operation of -100 kV, 25 A DC power supply with 1 MW, 352.2 MHz klystron amplifier. (author)

  13. Rationale and design of the screening of pulmonary hypertension in systemic lupus erythematosus (SOPHIE) study.

    Science.gov (United States)

    Huang, Duo; Cheng, Yang-Yang; Chan, Pak-Hei; Hai, Jojo; Yiu, Kai-Hang; Tse, Hung-Fat; Wong, Ka-Lam; Fan, Katherine; Li, Ying Wah; Ng, Woon-Leung; Yim, Cheuk-Wan; Wong, Cheuk-Hon John; Tam, Lai-Shan; Wong, Priscilla C H; Wong, Chi-Yuen; Ho, Chup-Hei; Leung, Alexander M H; Mok, Chi-Chiu; Lam, Ho; Lau, Chak-Sing; Cheung, Tommy; Ho, Carmen; Law, Sharon W Y; Chan, Esther W; Yin, Li-Xue; Yue, Wen-Sheng; Mok, Toi Meng; Evora, Mario Alberto; Siu, Chung-Wah

    2018-01-01

    Current guideline-recommended screening for pulmonary hypertension in patients with systemic sclerosis has not been evaluated in systemic lupus erythematosus (SLE), which is disproportionately prevalent in Asians. This multicentre, cross-sectional screening study aims to study the prevalence of pulmonary hypertension among SLE patients using these guidelines, and identify independent predictors and develop a prediction model for pulmonary hypertension in SLE patients. SLE patients from participating centres will undergo an echocardiography- and biomarker-based pulmonary hypertension screening procedure as in the DETECT study. Standard right heart catheterisation will be provided to patients with intermediate or high echocardiographic probability of pulmonary hypertension. Those with low echocardiographic probability will rescreen within 1 year. The primary measure will be the diagnosis and types of pulmonary hypertension and prevalence of pulmonary hypertension in SLE patients. The secondary measures will be the predictors and prediction models for pulmonary hypertension in SLE patients. The estimated sample size is approximately 895 participants. The results of the SOPHIE study will be an important contribution to the literature of SLE-related pulmonary hypertension and may be immediately translatable to real clinical practice. Ultimately, this study will provide the necessary evidence for establishing universal guidelines for screening of pulmonary hypertension in SLE patients.

  14. A new in vitro screening system for anticancer drugs for the treatment of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Hanauske, U.; Hanauske, A.R.; Clark, G.M.; Tsen, D.; Buchok, J.; Hoff, D.D. von

    1989-01-01

    We have evaluated a semiautomated radiometric assay (BACTEC 460 system) for screening of activity of anticancer drugs against human non-small cell lung cancer cell lines. Cells from seven cell lines were exposed to standard antineoplastic agents at four different concentrations using a 1-h incubation. Alpha 2-interferon was tested using a continuous incubation. In vitro drug activity was analyzed as a function of the clinically achievable serum concentration. Our results indicate that two cell lines (CALU-3, SK-MES-1) exhibit in vitro drug sensitivity patterns closest to those observed in clinical studies. These two cell lines might therefore be most useful for screening new anticancer compounds for activity against non-small cell lung cancer. The radiometric assay is a semiautomated system which has advantages over other, more time-consuming screening systems

  15. Quality Control and Complication Screening Programme of Chinese Medicinal Drugs at the First German Hospital of Traditional Chinese Medicine - A Retrospective Analysis.

    Science.gov (United States)

    Melchart, Dieter; Hager, Stefan; Dai, Jingzhang; Weidenhammer, Wolfgang

    2016-01-01

    The use of drugs derived from plants is a cornerstone of Traditional Chinese Medicine (TCM). Yet, too little is known about risk and safety of Chinese medicinal drugs (CMD). Therefore, the TCM hospital Bad Kötzting has developed a quality control and complication screening programme in order to ensure a safe administration of TCM drugs to their patients. All Chinese medicinal drugs delivered to the hospital between September 1, 2012 and December 31, 2013 entered the quality control program and were screened for microbial contamination, aflatoxin, pesticides and heavy metals. A routinely applied complication screening programme monitored liver enzymes in all patients. Case causality assessment by CIOMS scale and identification of admitted herbs were conducted. Additionally, side effects of patients were identified by a routinely performed web-based documentation system. In 5 of 23 investigated samples (21.7%) the initial testing showed microbial contamination (2), pesticide (2) and heavy metals (1). The drugs were tested for authenticity and adulterations, respectively. All 994 patients (mean age 52.6 years; 72.6% female) admitted were available for analysis. 448 (45.1%) of all patients reported having perceived at least one side effect of treatment. They experienced mainly gastrointestinal symptoms (13.6%), neurovegetative symptoms (10.8 %), temporary deteriorations of pain (8.8%), diarrhoea (5.9%), nausea (1.6%) and vomiting (0.5%). Further, 6 patients with a more than 2-fold elevation (compared to maximum normal value or elevated admission values) of ALT were found in the systematic laboratory control with a non-conclusive causality assessment for TCM-drugs. Approximate incidence rates and analysed drugs associated with liver damage revealed a low rate of liver injury. Patients should be informed of the gastrointestinal symptoms caused by and potential hepatotoxicity of TCM herbs. © 2016 S. Karger GmbH, Freiburg.

  16. The association between state mandates of colorectal cancer screening coverage and colorectal cancer screening utilization among US adults aged 50 to 64 years with health insurance

    Directory of Open Access Journals (Sweden)

    Virgo Katherine

    2011-01-01

    Full Text Available Abstract Background Several states in the US have passed laws mandating coverage of colorectal cancer (CRC screening tests by health insurance plans. The impact of these state mandates on the use of colorectal cancer screening has not been evaluated among an age-eligible target population with access to care (i.e., health care insurance coverage. Methods We collected information on state mandates implemented by December 31, 2008 and used data on insured adults aged 50 and 64 years from the Behavioral Risk Factor Surveillance System between 2002 and 2008 to classify individual-level exposure to state mandates for at least 1 year. Multivariate logistic regression models (with state- and year- fixed effects, and patient demographic and socioeconomic characteristics were used to estimate the effect of state mandates on recent endoscopy screening (either flexible sigmoidoscopy or colonoscopy during the past year. Results From 1999-2008, twenty-two states in the US, including the District of Columbia passed comprehensive laws requiring health insurance coverage of CRC screening including endoscopy tests. Residence in states with CRC screening coverage mandates in place for at least 1 year was associated with a 1.4 percentage point increase in the probability of utilization of recent endoscopy (i.e., 17.5% screening rates in those with mandates versus 16.1% in those without, Adjusted OR = 1.10, 95% CI: 1.02 - 1.20, p = 0.02. Conclusions The findings suggest a positive, albeit small, impact of state mandates on the use of recent CRC screening endoscopy among the target eligible population with health insurance. However, more research is needed to evaluate potential effects of mandates across health insurance types while including controls for other system-level factors (e.g. endoscopy and primary care capacity. National health insurance reform should strive towards a system that expands access to recommended CRC screening tests.

  17. Newborn screening for galactosaemia.

    Science.gov (United States)

    Lak, Rohollah; Yazdizadeh, Bahareh; Davari, Majid; Nouhi, Mojtaba; Kelishadi, Roya

    2017-12-23

    Classical galactosaemia is an autosomal recessive inborn error of metabolism caused by a deficiency of the enzyme galactose-1-phosphate uridyltransferase. This is a rare and potentially lethal condition that classically presents in the first week of life once milk feeds have commenced. Affected babies may present with any or all of the following: cataracts; fulminant liver failure; prolonged jaundice; or Escherichia coli sepsis. Once the diagnosis is suspected, feeds containing galactose must be stopped immediately and replaced with a soya-based formula. The majority of babies will recover, however a number will not survive. There are long-term complications of galactosaemia, despite treatment, including learning disabilities and female infertility. It has been postulated that galactosaemia could be detected on newborn screening and this would prevent the immediate severe liver dysfunction and sepsis. To assess whether there is evidence that newborn screening for galactosaemia prevents or reduces mortality and morbidity and improves clinical outcomes in affected neonates and the quality of life in older children. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from electronic database searches, handsearches of relevant journals and conference abstract books. We also searched online trials registries and the reference lists of relevant articles and reviews.Date of the most recent search of Cochrane Cystic Fibrosis Group's Trials Register: 18 December 2017.Date of the most recent search of additional resources: 11 October 2017. Randomised controlled studies and controlled clinical studies, published or unpublished comparing the use of any newborn screening test to diagnose infants with galactosaemia and presenting a comparison between a screened population versus a non-screened population. No studies of newborn screening for galactosaemia were found. No studies were identified for inclusion in the

  18. A national control system

    International Nuclear Information System (INIS)

    Larsson, A.

    1975-01-01

    An effective control of nuclear fissionable material is dependent on three different kinds of control, the industry - laboratory management, a national control system and an international safeguards system. The national systems of control differ greatly between various industrialized countries. Two principal reasons for fact can be mentioned. The type and the amounts for nuclear material may be different depending upon the stage of development of the nuclear industry in the country in question. Another reason may be that the country may wish to establish a very elaborate national system of control in order to minimize the IAEA control as much as possible. The two safeguards agreements between the Agency and Sweden on one hand and the Agency and Japan on the other hand can serve as examples for the understanding of the latitude of the IAEA safeguards system under NPT due to the influence of the national control system. If it thus is apparent that the national control system is strongly interrelated to the international safeguards system it is equally influenced by the control and accountancy systems which exist at the nuclear plants and development laboratories. A detailed study of national control systems and their relations to plant management control would fall outside the scope of this article. Some important features will however be examined. (author)

  19. Fouling control mechanisms of demineralized water backwash: Reduction of charge screening and calcium bridging effects

    KAUST Repository

    Li, Sheng

    2011-12-01

    This paper investigates the impact of the ionic environment on the charge of colloidal natural organic matter (NOM) and ultrafiltration (UF) membranes (charge screening effect) and the calcium adsorption/bridging on new and fouled membranes (calcium bridging effect) by measuring the zeta potentials of membranes and colloidal NOM. Fouling experiments were conducted with natural water to determine whether the reduction of the charge screening effect and/or calcium bridging effect by backwashing with demineralized water can explain the observed reduction in fouling. Results show that the charge of both membranes and NOM, as measured by the zeta potential, became more negative at a lower pH and a lower concentration of electrolytes, in particular, divalent electrolytes. In addition, calcium also adsorbed onto the membranes, and consequently bridged colloidal NOM and membranes via binding with functional groups. The charge screening effect could be eliminated by flushing NOM and membranes with demineralized water, since a cation-free environment was established. However, only a limited amount of the calcium bridging connection was removed with demineralized water backwashes, so the calcium bridging effect mostly could not be eliminated. As demineralized water backwash was found to be effective in fouling control, it can be concluded that the reduction of the charge screening is the dominant mechanism for this. © 2011 Elsevier Ltd.

  20. An Auto-Tuning PI Control System for an Open-Circuit Low-Speed Wind Tunnel Designed for Greenhouse Technology

    Directory of Open Access Journals (Sweden)

    Karlos Espinoza

    2015-08-01

    Full Text Available Wind tunnels are a key experimental tool for the analysis of airflow parameters in many fields of application. Despite their great potential impact on agricultural research, few contributions have dealt with the development of automatic control systems for wind tunnels in the field of greenhouse technology. The objective of this paper is to present an automatic control system that provides precision and speed of measurement, as well as efficient data processing in low-speed wind tunnel experiments for greenhouse engineering applications. The system is based on an algorithm that identifies the system model and calculates the optimum PI controller. The validation of the system was performed on a cellulose evaporative cooling pad and on insect-proof screens to assess its response to perturbations. The control system provided an accuracy of <0.06 m·s‾1 for airflow speed and <0.50 Pa for pressure drop, thus permitting the reproducibility and standardization of the tests. The proposed control system also incorporates a fully-integrated software unit that manages the tests in terms of airflow speed and pressure drop set points.

  1. Validation of the MASK-rhinitis visual analogue scale on smartphone screens to assess allergic rhinitis control

    NARCIS (Netherlands)

    Caimmi, D.; Baiz, N.; Tanno, L. K.; Demoly, P.; Arnavielhe, S.; Murray, R.; Bedbrook, A.; Bergmann, K. C.; de Vries, G.; Fokkens, W. J.; Fonseca, J.; Haahtela, T.; Keil, T.; Kuna, P.; Mullol, J.; Papadopoulos, N.; Passalacqua, G.; Samolinski, B.; Tomazic, P. V.; Valiulis, A.; van Eerd, M.; Wickman, M.; Annesi-Maesano, I.; Bousquet, J.; Agache, I.; Angles, R.; Anto, J. M.; Asayag, E.; Bacci, E.; Bachert, C.; Baroni, I.; Barreto, B. A.; Bedolla-Barajas, M.; Bertorello, L.; Bewick, M.; Bieber, T.; Birov, S.; Bindslev-Jensen, C.; Blua, A.; Bochenska Marciniak, M.; Bogus-Buczynska, I.; Bosnic-Ancevich, S.; Bosse, I.; Bourret, R.; Bucca, C.; Buonaiuto, R.; Caiazza, D.; Caillot, D.; Caimmi, D. P.; Camargos, P.; Canfora, G.; Cardona, V.; Carriazo, A. M.; Cartier, C.; Castellano, G.; Chavannes, N. H.; Ciaravolo, M. M.; Cingi, C.; Ciceran, A.; Colas, L.; Colgan, E.; Coll, J.; Conforti, D.; Correira de Sousa, J.; Cortés-Grimaldo, R. M.; Corti, F.; Costa, E.; Courbis, A. L.; Cruz, A.; Custovic, A.; Dario, C.; da Silva, M.; Dauvilliers, Y.; de Blay, F.; Dedeu, T.; de Feo, G.; de Martino, B.; Di Capua, S.; Di Carluccio, N.; Dray, G.; Dubakiene, R.; Eller, E.; Emuzyte, R.; Espinoza-Contreras, J. M.; Estrada-Cardona, A.; Farrell, J.; Ferrero, J.; Fontaine, J. F.; Forti, S.; Gálvez-Romero, J. L.; Garcia Cruz, M. H.; García-Cobas, C. I.; Gemicioğlu, B.; Gerth van Wijck, R.; Guidacci, M.; Gómez-Vera, J.; Guldemond, N. A.; Gutter, Z.; Hajjam, J.; Hellings, P.; Hernández-Velázquez, L.; Illario, M.; Ivancevich, J. C.; Jares, E.; Joos, G.; Just, J.; Kalayci, O.; Kalyoncu, A. F.; Karjalainen, J.; Khaltaev, N.; Klimek, L.; Kull, I.; Kuna, T. P.; Kvedariene, V.; Kolek, V.; Krzych-Fałta, E.; Kupczyk, M.; Lacwik, P.; Larenas-Linnemann, D.; Laune, D.; Lauri, D.; Lavrut, J.; Lessa, M.; Levato, G.; Lewis, L.; Lieten, I.; Lipiec, A.; Louis, R.; Luna-Pech, J. A.; Magnan, A.; Malva, J.; Maspero, J. F.; Mayora, O.; Medina-Ávalos, M. A.; Melen, E.; Menditto, E.; Millot-Keurinck, J.; Moda, G.; Morais-Almeida, M.; Mösges, R.; Mota-Pinto, A.; Muraro, A.; Noguès, M.; Nalin, M.; Napoli, L.; Neffen, H.; O'Hehir, R.; Olivé Elias, M.; Onorato, G.; Palkonen, S.; Pépin, J. L.; Pereira, A. M.; Persico, M.; Pfaar, O.; Pozzi, A. C.; Prokopakis, E. P.; Raciborski, F.; Rizzo, J. A.; Robalo-Cordeiro, C.; Rodríguez-González, M.; Rolla, G.; Roller-Wirnsberger, R. E.; Romano, A.; Romano, M.; Salimäki, J.; Serpa, F. S.; Shamai, S.; Sierra, M.; Sova, M.; Sorlini, M.; Stellato, C.; Stelmach, R.; Strandberg, T.; Stroetman, V.; Stukas, R.; Szylling, A.; Tibaldi, V.; Todo-Bom, A.; Toppila-Salmi, S.; Tomazic, P.; Trama, U.; Triggiani, M.; Valero, A.; Valovirta, E.; Vasankari, T.; Vatrella, A.; Ventura, M. T.; Verissimo, M. T.; Viart, F.; Williams, S.; Wagenmann, M.; Wanscher, C.; Westman, M.; Young, I.; Yorgancioglu, A.; Zernotti, E.; Zurbierber, T.; Zurkuhlen, A.; de Oliviera, B.; Senn, A.

    2017-01-01

    Background: Visual Analogue Scale (VAS) is a validated tool to assess control in allergic rhinitis patients. Objective: The aim of this study was to validate the use of VAS in the MASK-rhinitis (MACVIA-ARIA Sentinel NetworK for allergic rhinitis) app (Allergy Diary) on smartphones screens to

  2. An alternative method for noise analysis using pixel variance as part of quality control procedures on digital mammography systems.

    NARCIS (Netherlands)

    Bouwman, R.; Young, K.; Lazzari, B.; Ravaglia, V.; Broeders, M.J.M.; Engen, R. van

    2009-01-01

    According to the European Guidelines for quality assured breast cancer screening and diagnosis, noise analysis is one of the measurements that needs to be performed as part of quality control procedures on digital mammography systems. However, the method recommended in the European Guidelines does

  3. Operation Request Gatekeeper: A software system for remote access control of diagnostic instruments in fusion experiments

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D. P.; Fredian, T. W.; Stillerman, J. A.; Greenwald, M. J.; Stepanov, D. N.; Ciarlette, D. J.

    2010-01-01

    Tokamak diagnostic settings are repeatedly modified to meet the changing needs of each experiment. Enabling the remote diagnostic control has significant challenges due to security and efficiency requirements. The Operation Request Gatekeeper (ORG) is a software system that addresses the challenges of remotely but securely submitting modification requests. The ORG provides a framework for screening all the requests before they enter the secure machine zone and are executed by performing user authentication and authorization, grammar validation, and validity checks. A prototype ORG was developed for the ITER CODAC that satisfies their initial requirements for remote request submission and has been tested with remote control of the KSTAR Plasma Control System. This paper describes the software design principles and implementation of ORG as well as worldwide test results.

  4. Development of computational program for studying the reactor control system in PWR plants; Desenvolvimento de um programa computacional para estudo do sistema de controle do reator em plantas PWR

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jose Ricardo de; Soares, Adalberto Jose [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2002-07-01

    In this work a computational program is presented which has been developed for specific application on the study of the reactor control system of a typical PWR plant. As to the basic function of simulating power transients the program has the following structure: a representative mathematical model of the dynamic and stationary behaviors of the primary circuit; a group of equations associated to the reactor power control and system pressure control; screens for the entry of reference data as well as of control blocks and control bar speed programming module parameters; main entering screens for the configuration of the excitement/transient function as well as of simulation time and control mood; and graphical output of all the process variables incorporated to the model. As premise it has been considered as sufficient the modeling of the primary circuit, a differential equation being used which associates the average temperature of the coolant within the steam generator with the potency transferred to the secondary circuit, denominated 'secondary potency', as an interface with the secondary circuit. Every transient - ramp or step - is established upon the 'turbine power' variable, which in turn is related to the 'secondary power' variable by means of a differential equation that represents a first - order delay, having adjustable parameters on the data - entry screen. In the neutronic model as defined for the reactor, the reactivity feedback effects due to primary circuit pressure variation, as well as fuel and coolant temperature variation, were taken into consideration. Thermo-hydraulics constants and project data taken from the available bibliography, adapted to a particular small PWR unit conception , were employed for loading the program. With the open-loop simulation results a positive qualitative evaluation of the program was obtained, in comparison to published results related to simulators bearing equal purposes, more

  5. Management of Control System Information SecurityI: Control System Patch Management

    Energy Technology Data Exchange (ETDEWEB)

    Quanyan Zhu; Miles McQueen; Craig Rieger; Tamer Basar

    2011-09-01

    The use of information technologies in control systems poses additional potential threats due to the frequent disclosure of software vulnerabilities. The management of information security involves a series of policy-making on the vulnerability discovery, disclosure, patch development and patching. In this paper, we use a system approach to devise a model to understand the interdependencies of these decision processes. In more details, we establish a theoretical framework for making patching decision for control systems, taking into account the requirement of functionability of control systems. We illustrate our results with numerical simulations and show that the optimal operation period of control systems given the currently estimated attack rate is roughly around a half a month.

  6. Dynamic Systems and Control Engineering

    International Nuclear Information System (INIS)

    Kim, Jong Seok

    1994-02-01

    This book deals with introduction of dynamic system and control engineering, frequency domain modeling of dynamic system, temporal modeling of dynamic system, typical dynamic system and automatic control device, performance and stability of control system, root locus analysis, analysis of frequency domain dynamic system, design of frequency domain dynamic system, design and analysis of space, space of control system and digital control system such as control system design of direct digital and digitalization of consecutive control system.

  7. Dynamic Systems and Control Engineering

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Seok

    1994-02-15

    This book deals with introduction of dynamic system and control engineering, frequency domain modeling of dynamic system, temporal modeling of dynamic system, typical dynamic system and automatic control device, performance and stability of control system, root locus analysis, analysis of frequency domain dynamic system, design of frequency domain dynamic system, design and analysis of space, space of control system and digital control system such as control system design of direct digital and digitalization of consecutive control system.

  8. SYNTHESIS OF ACTIVE SCREENING SYSTEM OF MAGNETIC FIELD OF HIGH VOLTAGE POWER LINES OF DIFFERENT DESIGN TAKING INTO ACCOUNT SPATIAL AND TEMPORAL DISTRIBUTION OF MAGNETIC FIELD

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2017-04-01

    Full Text Available Purpose. Analyze the spatial and temporal distribution of the magnetic field of high voltage power lines with different design allowing and development of recommendations for the design of active screening systems by magnetic field of high voltage power lines. Methodology. Analysis of the spatial and temporal distribution of the magnetic field of high voltage power lines of different design allowing is made on the basis of Maxwell's equations solutions in the quasi-stationary approximation. Determination of the number, configuration, spatial arrangement and the compensation coil currents is formulated in the form of multiobjective optimization problem that is solved by multi-agent multiswarm stochastic optimization based on Pareto optimal solutions. Results of active screening system for the synthesis of various types of transmission lines with different numbers of windings controlled. The possibility of a significant reduction in the level of the flux density of the magnetic field source within a given region of space. Originality. For the first time an analysis of the spatial and temporal distribution of the magnetic field of power lines with different types and based on findings developed recommendations for the design of active screening system by magnetic field of high voltage power lines. Practical value. Practical recommendations on reasonable choice of the number and spatial arrangement of compensating windings of active screening system by magnetic field of high voltage power lines of different design allowing for the spatial and temporal distribution of the magnetic field. Results of active screening system synthesis of the magnetic field of industrial frequency generated by single-circuit 110 kV high voltage power lines with the supports have 330 - 1T «triangle» rotating magnetic field with full polarization in a residential five-storey building, located near the power lines. The system contains three compensating coil and reduces

  9. Computer control of the high-voltage power supply for the DIII-D Electron Cyclotron Heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1991-10-01

    The D3-D Electron Cyclotron Heating (ECH) high voltage power supply is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interface is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished, physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplied, each with its own database, through a single computer and console. 5 refs., 4 figs., 1 tab

  10. Screening sensitivity theory

    International Nuclear Information System (INIS)

    Oblow, E.M.; Perey, F.G.

    1984-01-01

    A comprehensive rigorous theory is developed for screening sensitivity coefficients in largescale modeling applications. The theory uses Bayesian inference and group theory to establish a probabilistic framework for solving an underdetermined system of linear equations. The underdetermined problem is directly related to statistical screening sensitivity theory as developed in recent years. Several examples of the new approach to screening are worked out in detail and comparisons are made with statistical approaches to the problem. The drawbacks of these latter methods are discussed at some length

  11. A new ball launching system with controlled flight parameters for catching experiments.

    Science.gov (United States)

    d'Avella, A; Cesqui, B; Portone, A; Lacquaniti, F

    2011-03-30

    Systematic investigations of sensorimotor control of interceptive actions in naturalistic conditions, such as catching or hitting a ball moving in three-dimensional space, requires precise control of the projectile flight parameters and of the associated visual stimuli. Such control is challenging when air drag cannot be neglected because the mapping of launch parameters into flight parameters cannot be computed analytically. We designed, calibrated, and experimentally validated an actuated launching apparatus that can control the average spatial position and flight duration of a ball at a given distance from a fixed launch location. The apparatus was constructed by mounting a ball launching machine with adjustable delivery speed on an actuated structure capable of changing the spatial orientation of the launch axis while projecting balls through a hole in a screen hiding the apparatus. The calibration procedure relied on tracking the balls with a motion capture system and on approximating the mapping of launch parameters into flight parameters by means of polynomials functions. Polynomials were also used to estimate the variability of the flight parameters. The coefficients of these polynomials were obtained using the launch and flight parameters of 660 launches with 65 different initial conditions. The relative accuracy and precision of the apparatus were larger than 98% for flight times and larger than 96% for ball heights at a distance of 6m from the screen. Such novel apparatus, by reliably and automatically controlling desired ball flight characteristics without neglecting air drag, allows for a systematic investigation of naturalistic interceptive tasks. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. An engineering development of fluoroscopic X-ray medical equipment based-on fluorescent screen

    International Nuclear Information System (INIS)

    Ferry Suyatno; I Putu Susila; Djoko Sukmono

    2011-01-01

    Fluoroscopic x-ray medical equipment uses fluorescent screen to capture structural image of organs. Unlike conventional x-ray equipment which uses film, in the fluoroscopic x-ray, the resulting image is visualized on the fluorescent screen and directly observed by physicians in the patients' rooms. In this study, we developed an image capture system that transforms the image on the fluorescent screen into digital data, which is then transferred to computer for visualization and further processing. By using this system, the observation of the resulting image can be done on a computer that is placed in the control room. The image can also be stored easily and at low cost compared to conventional film. The experiment shows that the system could be used to capture image of the object. However, its quality needs to be improved. In the future, the system will be modified and tested with different types of cameras to obtain better results. (author)

  13. Factors Influencing Colorectal Cancer Screening Participation

    Directory of Open Access Journals (Sweden)

    Antonio Z. Gimeno García

    2012-01-01

    Full Text Available Colorectal cancer (CRC is a major health problem worldwide. Although population-based CRC screening is strongly recommended in average-risk population, compliance rates are still far from the desirable rates. High levels of screening uptake are necessary for the success of any screening program. Therefore, the investigation of factors influencing participation is crucial prior to design and launches a population-based organized screening campaign. Several studies have identified screening behaviour factors related to potential participants, providers, or health care system. These influencing factors can also be classified in non-modifiable (i.e., demographic factors, education, health insurance, or income and modifiable factors (i.e., knowledge about CRC and screening, patient and provider attitudes or structural barriers for screening. Modifiable determinants are of great interest as they are plausible targets for interventions. Interventions at different levels (patient, providers or health care system have been tested across the studies with different results. This paper analyzes factors related to CRC screening behaviour and potential interventions designed to improve screening uptake.

  14. Automation of High-Throughput Crystal Screening and Data Collection at SSRL

    International Nuclear Information System (INIS)

    Miller, Mitchell D.; Brinen, Linda S.; Deacon, Ashley M.; Bedem, Henry van den; Wolf, Guenter; Xu Qingping; Zhang Zepu; Cohen, Aina; Ellis, Paul; McPhillips, Scott E.; McPhillips, Timothy M.; Phizackerley, R. Paul; Soltis, S. Michael

    2004-01-01

    A robotic system for auto-mounting crystals from liquid nitrogen is now operational on SSRL beamlines (Cohen et al., J. Appl. Cryst. (2002). 35, 720-726). The system uses a small industrial 4-axis robot with a custom built actuator. Once mounted, automated alignment of the sample loop to the X-ray beam readies the crystal for data collection. After data collection, samples are returned to the cassette. The beamline Dewar accommodates three compact sample cassettes (holding up to 96 samples each). During the past 4 months, the system on beamline 11-1 has been used to screen over 1000 crystals. The system has reduced both screening time and manpower. Integration of the hardware components is accomplished in the Distributed Control System architecture developed at SSRL (McPhillips et al., J. Synchrotron Rad. (2002) 9, 401-406). A crystal-screening interface has been implemented in Blu-Ice. Sample details can be uploaded from an Excel spreadsheet. The JCSG generates these spreadsheets automatically from their tracking database using standard database tools (http://www.jcsg.org). New diffraction image analysis tools are being employed to aid in extracting results. Automation also permits tele-presence. For example, samples have been changed during the night without leaving home and scientists have screened crystals 1600 miles from the beamline. The system developed on beamline 11-1 has been replicated onto 1-5, 9-1, 9-2, and 11-3 and is used by both general users and the JCSG

  15. Automatic control systems engineering

    International Nuclear Information System (INIS)

    Shin, Yun Gi

    2004-01-01

    This book gives descriptions of automatic control for electrical electronics, which indicates history of automatic control, Laplace transform, block diagram and signal flow diagram, electrometer, linearization of system, space of situation, state space analysis of electric system, sensor, hydro controlling system, stability, time response of linear dynamic system, conception of root locus, procedure to draw root locus, frequency response, and design of control system.

  16. Systematic screening with information and home sampling for genital Chlamydia trachomatis infections in young men and women in Norway: a randomized controlled trial.

    Science.gov (United States)

    Kløvstad, Hilde; Natås, Olav; Tverdal, Aage; Aavitsland, Preben

    2013-01-23

    As most genital Chlamydia trachomatis infections are asymptomatic, many patients do not seek health care for testing. Infections remain undiagnosed and untreated. We studied whether screening with information and home sampling resulted in more young people getting tested, diagnosed and treated for chlamydia in the three months following the intervention compared to the current strategy of testing in the health care system. We conducted a population based randomized controlled trial among all persons aged 18-25 years in one Norwegian county (41 519 persons). 10 000 persons (intervention) received an invitation by mail with chlamydia information and a mail-back urine sampling kit. 31 519 persons received no intervention and continued with usual care (control). All samples from both groups were analysed in the same laboratory. Information on treatment was obtained from the Norwegian Prescription Database (NorPD). We estimated risk ratios and risk differences of being tested, diagnosed and treated in the intervention group compared to the control group. In the intervention group 16.5% got tested and in the control group 3.4%, risk ratio 4.9 (95% CI 4.5-5.2). The intervention led to 2.6 (95% CI 2.0-3.4) times as many individuals being diagnosed and 2.5 (95% CI 1.9-3.4) times as many individuals receiving treatment for chlamydia compared to no intervention in the three months following the intervention. In Norway, systematic screening with information and home sampling results in more young people being tested, diagnosed and treated for chlamydia in the three months following the intervention than the current strategy of testing in the health care system. However, the study has not established that the intervention will reduce the chlamydia prevalence or the risk of complications from chlamydia.

  17. Control and automation systems

    International Nuclear Information System (INIS)

    Schmidt, R.; Zillich, H.

    1986-01-01

    A survey is given of the development of control and automation systems for energy uses. General remarks about control and automation schemes are followed by a description of modern process control systems along with process control processes as such. After discussing the particular process control requirements of nuclear power plants the paper deals with the reliability and availability of process control systems and refers to computerized simulation processes. The subsequent paragraphs are dedicated to descriptions of the operating floor, ergonomic conditions, existing systems, flue gas desulfurization systems, the electromagnetic influences on digital circuits as well as of light wave uses. (HAG) [de

  18. On the Development of a Web-Based M-Learning System for Dual Screen Handheld Game Consoles

    Directory of Open Access Journals (Sweden)

    Hend S. Al-Khalifa

    2011-04-01

    Full Text Available This paper presents our experience on the design and development of an M-Learning web-based system for the Nintendo DSi game console. The paper starts by addressing the difficulties that emerged from the lack of resources on design guidelines for dual screen devices also the absence of adequate techniques and methods to support the design decisions. Then it explains how we overcame these challenges by adopting a design decision suitable for the screen requirements of the Nintendo DSi console. Finally, we present the components of our M-Learning system and the results of a preliminary usability evaluation.

  19. Genetic and epigenetic control of gene expression by CRISPR–Cas systems

    Science.gov (United States)

    Lo, Albert; Qi, Lei

    2017-01-01

    The discovery and adaption of bacterial clustered regularly interspaced short palindromic repeats (CRISPR)–CRISPR-associated (Cas) systems has revolutionized the way researchers edit genomes. Engineering of catalytically inactivated Cas variants (nuclease-deficient or nuclease-deactivated [dCas]) combined with transcriptional repressors, activators, or epigenetic modifiers enable sequence-specific regulation of gene expression and chromatin state. These CRISPR–Cas-based technologies have contributed to the rapid development of disease models and functional genomics screening approaches, which can facilitate genetic target identification and drug discovery. In this short review, we will cover recent advances of CRISPR–dCas9 systems and their use for transcriptional repression and activation, epigenome editing, and engineered synthetic circuits for complex control of the mammalian genome. PMID:28649363

  20. Control system design guide

    Energy Technology Data Exchange (ETDEWEB)

    Sellers, David; Friedman, Hannah; Haasl, Tudi; Bourassa, Norman; Piette, Mary Ann

    2003-05-01

    The ''Control System Design Guide'' (Design Guide) provides methods and recommendations for the control system design process and control point selection and installation. Control systems are often the most problematic system in a building. A good design process that takes into account maintenance, operation, and commissioning can lead to a smoothly operating and efficient building. To this end, the Design Guide provides a toolbox of templates for improving control system design and specification. HVAC designers are the primary audience for the Design Guide. The control design process it presents will help produce well-designed control systems that achieve efficient and robust operation. The spreadsheet examples for control valve schedules, damper schedules, and points lists can streamline the use of the control system design concepts set forth in the Design Guide by providing convenient starting points from which designers can build. Although each reader brings their own unique questions to the text, the Design Guide contains information that designers, commissioning providers, operators, and owners will find useful.

  1. Indirect control of quantum systems via an accessor: pure coherent control without system excitation

    International Nuclear Information System (INIS)

    Fu, H C; Dong Hui; Sun, C P; Liu, X F

    2009-01-01

    A pure indirect control of quantum systems via a quantum accessor is investigated. In this control scheme, we do not apply any external classical excitation fields on the controlled system and we control a quantum system via a quantum accessor and classical control fields control the accessor only. Complete controllability is investigated for arbitrary finite-dimensional quantum systems and exemplified by two- and three-dimensional systems. The scheme exhibits some advantages; it uses less qubits in the accessor and does not depend on the energy-level structure of the controlled system

  2. Intelligent control systems 1990

    International Nuclear Information System (INIS)

    Shoureshi, R.

    1991-01-01

    The field of artificial intelligence (Al) has generated many useful ideas and techniques that can be integrated into the design of control systems. It is believed and, for special cases, has been demonstrated, that integration of Al into control systems would provide the necessary tools for solving many of the complex problems that present control techniques and Al algorithms are unable to do, individually. However, this integration requires the development of basic understanding and new fundamentals to provide scientific bases for achievement of its potential. This book presents an overview of some of the latest research studies in the area of intelligent control systems. These papers present techniques for formulation of intelligent control, and development of the rule-based control systems. Papers present applications of control systems in nuclear power plants and HVAC systems

  3. Screening for skin cancer.

    Science.gov (United States)

    Helfand, M; Mahon, S M; Eden, K B; Frame, P S; Orleans, C T

    2001-04-01

    of referrals, types of suspected skin cancers, biopsies, confirmed skin cancers, and stages and thickness of skin cancers. For studies that reported test performance, we recorded the definition of a suspicious lesion, the "gold-standard" determination of disease, and the number of true positive, false positive, true negative, and false negative test results. When possible, positive predictive values, likelihood ratios, sensitivity, and specificity were recorded. No randomized or case-control studies have been done that demonstrate that routine screening for melanoma by primary care providers reduces morbidity or mortality. Basal cell carcinoma and squamous cell carcinoma are very common, but detection and treatment in the absence of formal screening are almost always curative. No controlled studies have shown that formal screening programs will improve this already high cure rate. While the efficacy of screening has not been established, the screening procedures themselves are noninvasive, and the follow-up test, skin biopsy, has low morbidity. Five studies from mass screening programs reported the accuracy of skin examination as a screening test. One of these, a prospective study, tracked patients with negative results to determine the number of patients with false-negative results. In this study, the sensitivity of screening for skin cancer was 94% and specificity was 98%. Several recent case-control studies confirm earlier evidence that risk of melanoma rises with the presence of atypical moles and/or many common moles. One well-done prospective study demonstrated that risk assessment by limited physical exam identified a relatively small (fair. We found no studies that assessed the effectiveness of periodic skin examination by a clinician in reducing melanoma mortality. Both self-assessment of risk factors or clinician examination can classify a small proportion of patients as at highest risk for melanoma. Skin cancer screening, perhaps using a risk

  4. FFTF control system experience

    International Nuclear Information System (INIS)

    Warrick, R.P.

    1981-01-01

    The FFTF control systems provide control equipment for safe and efficient operation of the plant. For convenience, these systems will be divided into three parts for discussions: (1) Plant Protection System (PPS); (2) Plant Control System (PCS); and (3) General Observations. Performance of each of these systems is discussed

  5. Breast cancer screening; cost-effective in practice?

    International Nuclear Information System (INIS)

    Koning, Harry J. de

    2000-01-01

    the same for all countries. The effects of a breast-screening program depend on many factors, such as the epidemiology of the disease, the health care system, costs of health care, the quality of the screening programme and the attendance rate. The estimated CE-ratio ranges from 2650 euros per life-year gained in Navarra to 9650 in Germany. Although relatively low incidence levels expected, the CE-ratio in Navarra is most favourable probably due to a relatively unfavourable clinical stage distribution before screening and the increasing incidence. The UK has a screening situation that is almost similar with the Netherlands. Therefore, the CE-ratios of both countries are comparable. The differences between countries make it impossible to set up one uniform screening policy. The theoretical outcomes of the benefit that can be achieved are generally from small-scale trials involving a limited number of experts, persons examined, and areas. On a national scale, with hundreds of professional practitioners, it can be expected to be more difficult to attain uniform quality. Continuous quality control, monitoring and evaluation are therefore crucial

  6. A comparison of digital and screen-film mammography using quality control phantoms

    International Nuclear Information System (INIS)

    Undrill, Peter E.; O'Kane, Arlene D.; Gilbert, Fiona J.

    2000-01-01

    AIM: To compare the performance of a direct digital mammography system with normal-view and magnified-view conventional screen-film methods using quality control phantoms. MATERIALS AND METHODS: Using a Siemens Mammomat [reg] 3000 and an Opdima [reg] digital spot imaging and biopsy attachment, film and direct digital images of two phantoms [DuPont and TOR (MAM)] were obtained under normal operating conditions. These were assessed by three groups of observers with differing expertise -- radiologists, radiographers and medical physicists. Each observer was asked to compare the direct digital image with films taken in standard view and magnified view, providing scores for object visibility and confidence. For the digital images, observers were allowed to vary the image presentation parameters. RESULTS: Both phantoms showed that overall the direct digital view and the magnified view film performed significantly better (P < 0.05) than standard view film. For certain small or low contrast objects the differences became very highly significant (P < 0.001). CONCLUSION: Only the TOR (MAM) phantom showed any significant difference between digital and magnified modalities, with magnified views performing better for fine, faint filaments and digital acquisition better for low contrast objects. Almost no difference existed between the three observer groups. Undrill, P.E. (2000). Clinical Radiology 53, 782-790

  7. Acoustic Sample Deposition MALDI-MS (ASD-MALDI-MS): A Novel Process Flow for Quality Control Screening of Compound Libraries.

    Science.gov (United States)

    Chin, Jefferson; Wood, Elizabeth; Peters, Grace S; Drexler, Dieter M

    2016-02-01

    In the early stages of drug discovery, high-throughput screening (HTS) of compound libraries against pharmaceutical targets is a common method to identify potential lead molecules. For these HTS campaigns to be efficient and successful, continuous quality control of the compound collection is necessary and crucial. However, the large number of compound samples and the limited sample amount pose unique challenges. Presented here is a proof-of-concept study for a novel process flow for the quality control screening of small-molecule compound libraries that consumes only minimal amounts of samples and affords compound-specific molecular data. This process employs an acoustic sample deposition (ASD) technique for the offline sample preparation by depositing nanoliter volumes in an array format onto microscope glass slides followed by matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis. An initial study of a 384-compound array employing the ASD-MALDI-MS workflow resulted in a 75% first-pass positive identification rate with an analysis time of <1 s per sample. © 2015 Society for Laboratory Automation and Screening.

  8. Entry-Control Systems Handbook

    International Nuclear Information System (INIS)

    1978-09-01

    The function of an entry-control system in a total Physical Protection System is to allow the movement of authorized personnel and material through normal access routes, yet detect and delay unauthorized movement of personnel and material from uncontrolled areas. The ten chapters of this handbook cover: introduction, credentials, personnel identity verification systems, special nuclear materials monitors, metal detectors, explosives sensors, package search systems, criteria for selection of entry-control equipment, machine-aided manual entry-control systems, and automated entry-control systems. A system example and its cost are included as an appendix

  9. Analyzing Screening Policies for Childhood Obesity

    Science.gov (United States)

    Yang, Yan; Goldhaber-Fiebert, Jeremy D.; Wein, Lawrence M.

    2013-01-01

    Due to the health and economic costs of childhood obesity, coupled with studies suggesting the benefits of comprehensive (dietary, physical activity and behavioral counseling) intervention, the United States Preventive Services Task Force recently recommended childhood screening and intervention for obesity beginning at age six. Using a longitudinal data set consisting of the body mass index of 3164 children up to age 18 and another longitudinal data set containing the body mass index at ages 18 and 40 and the presence or absence of disease (hypertension and diabetes) at age 40 for 747 people, we formulate and numerically solve – separately for boys and girls – a dynamic programming problem for the optimal biennial (i.e., at ages 2, 4, …, 16) obesity screening thresholds. Unlike most screening problem formulations, we take a societal viewpoint, where the state of the system at each age is the population-wide probability density function of the body mass index. Compared to the biennial version of the task force’s recommendation, the screening thresholds derived from the dynamic program achieve a relative reduction in disease prevalence of 3% at the same screening (and treatment) cost, or – due to the flatness of the disease vs. screening tradeoff curve – achieves the same disease prevalence at a 28% relative reduction in cost. Compared to the task force’s policy, which uses the 95th percentile of body mass index (from cross-sectional growth charts tabulated by the Centers for Disease Control and Prevention) as the screening threshold for each age, the dynamic programming policy treats mostly 16 year olds (including many who are not obese) and very few males under 14 years old. While our results suggest that adult hypertension and diabetes are minimized by focusing childhood obesity screening and treatment on older adolescents, the shortcomings in the available data and the narrowness of the medical outcomes considered prevent us from making a

  10. A review of automatic exposure control of conventional and digital systems

    International Nuclear Information System (INIS)

    Workman, A.; Cowen, A.R.

    1989-01-01

    The desirable properties and methods of achieving automatic exposure control in film-screen radiography, fluoroscopy, spot-film fluorography and cinefluorography are discussed. Advantages of certain methods in achieving optimum image quality for minimal patient exposure are considered. In digital subtraction fluorography (DSF) where relatively large exposure levels per image are used, proper set-up of exposure conditions is of particular importance. These systems require a high degree of stability in exposure to maintain a high level of image quality. We have developed test methods for monitoring the set-up and reproducibility of exposure levels in DSF. (author)

  11. Evaluation of physical parameters and implementation of quality control in mammography diagnosed for a pilot of breast cancer screening in the Caja Costarricense de Seguro Social (CCSS)

    International Nuclear Information System (INIS)

    Hernandez Angulo, Carolina Maria

    2012-01-01

    The purpose of mammography has been to provide the contrast between the lesion and adjacent healthy tissue of the breast. The quality control which should be performed in mammography services is essential to obtain the necessary contrast in mammography and thus achieve a prompt detection of breast lesions. The quality control program has helped to obtain exact diagnosis in mammography and has contributed to reduce mortality from breast cancer in Costa Rica. The Caja Costarricense de Seguro Social (CCSS) has sought to improve the quality of mammograms performed in the different health centers by implementing quality control programs in the services. The evaluation of the physical parameters has had as aim to perform an assessment of the equipment used in mammography facilities. The image quality, dosimetry, optical density, performance, accuracy and repeatability of voltage applied to the tube, filtration and Half-value layer in system of screen film mammography have been evaluated. The usefulness of quality control programs and needs of the services to implement a pilot plan for breast screening, can be seen when comparing the obtained results. The protocol of Mammography Quality Control, TECDOC 1517 from the International Atomic Energy Agency (IAEA), is implemented with this project and the associated software in four of the six hospitals evaluated in this study. (author) [es

  12. Interval lung cancer after a negative CT screening examination: CT findings and outcomes in National Lung Screening Trial participants

    International Nuclear Information System (INIS)

    Gierada, David S.; Pinsky, Paul F.; Duan, Fenghai; Garg, Kavita; Hart, Eric M.; Kazerooni, Ella A.; Nath, Hrudaya; Watts, Jubal R.; Aberle, Denise R.

    2017-01-01

    This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. (orig.)

  13. Interval lung cancer after a negative CT screening examination: CT findings and outcomes in National Lung Screening Trial participants

    Energy Technology Data Exchange (ETDEWEB)

    Gierada, David S. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, Box 8131, St. Louis, MO (United States); Pinsky, Paul F. [National Cancer Institute, Bethesda, MD (United States); Duan, Fenghai [Brown University School of Public Health, Department of Biostatistics and Center for Statistical Sciences, Providence, RI (United States); Garg, Kavita [University of Colorado School of Medicine, Mail Stop F726, Box 6510, Aurora, CO (United States); Hart, Eric M. [Northwestern University, Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Kazerooni, Ella A. [University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Nath, Hrudaya; Watts, Jubal R. [University of Alabama at Birmingham School of Medicine, Department of Radiology-JTN370, Birmingham, AL (United States); Aberle, Denise R. [David Geffen School of Medicine at UCLA, Department of Radiological Sciences, Los Angeles, CA (United States)

    2017-08-15

    This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. (orig.)

  14. Gaze-controlled Driving

    DEFF Research Database (Denmark)

    Tall, Martin; Alapetite, Alexandre; San Agustin, Javier

    2009-01-01

    We investigate if the gaze (point of regard) can control a remote vehicle driving on a racing track. Five different input devices (on-screen buttons, mouse-pointing low-cost webcam eye tracker and two commercial eye tracking systems) provide heading and speed control on the scene view transmitted...

  15. Financial disincentives? A three-armed randomised controlled trial of the effect of financial Incentives  in Diabetic Eye Assessment  by Screening (IDEAS) trial.

    Science.gov (United States)

    Judah, Gaby; Darzi, Ara; Vlaev, Ivo; Gunn, Laura; King, Derek; King, Dominic; Valabhji, Jonathan; Bicknell, Colin

    2018-05-23

    Conflicting evidence exists regarding the impact of financial incentives on encouraging attendance at medical screening appointments. The primary aim was to determine whether financial incentives increase attendance at diabetic eye screening in persistent non-attenders. A three-armed randomised controlled trial was conducted in London in 2015. 1051 participants aged over 16 years, who had not attended eye screening appointments for 2 years or more, were randomised (1.4:1:1 randomisation ratio) to receive the usual invitation letter (control), an offer of £10 cash for attending screening (fixed incentive) or a 1 in 100 chance of winning £1000 (lottery incentive) if they attend. The primary outcome was the proportion of invitees attending screening, and a comparative analysis was performed to assess group differences. Pairwise comparisons of attendance rates were performed, using a conservative Bonferroni correction for independent comparisons. 34/435 (7.8%) of control, 17/312 (5.5%) of fixed incentive and 10/304 (3.3%) of lottery incentive groups attended. Participants who received any incentive were significantly less likely to attend their appointment compared with controls (risk ratio (RR)=0.56; 95% CI 0.34 to 0.92). Those in the probabilistic incentive group (RR=0.42; 95% CI 0.18 to 0.98), but not the fixed incentive group (RR=1.66; 95% CI 0.65 to 4.21), were significantly less likely to attend than those in the control group. Financial incentives, particularly lottery-based incentives, attract fewer patients to diabetic eye screening than standard invites in this population. Financial incentives should not be used to promote screening unless tested in context, as they may negatively affect attendance rates. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. A study of a reduction of patients' radiation exposure by using the new ortho screen film system

    International Nuclear Information System (INIS)

    Yagi, Hirofumi; Kuroda, Tokue.

    1994-01-01

    The developing temperatures dependency of the physical imaging properties of KONICA HI-ORTHO EXCELLENT SYSTEM (EX system) and KONICA MEDICAL SUPER RAPID SYSTEM (SR series) was evaluated by measuring characteristic curves, resolution properties and noise RMS. Furthermore, the possibility of a reduction of patients' radiation exposure without a decrease in imaging qualities was evaluated because the speed of screen/film systems increase as the developing temperature going up and the granularity of the EX system is greatly improved comparing with SR series. The physical imaging properties of screen/film systems were affected by the developing temperature. But the level of the effects on EX system was smaller than SR series. It was confirmed that the granularity of the EX system was improved greatly compared to SR series. Therefore, there is the possible reduction of patients' radiation exposure by increasing the developing temperature compared to the actual situation. (author)

  17. Effective modification of cell death-inducing intracellular peptides by means of a photo-cleavable peptide array-based screening system.

    Science.gov (United States)

    Kozaki, Ikko; Shimizu, Kazunori; Honda, Hiroyuki

    2017-08-01

    Intracellular functional peptides that play a significant role inside cells have been receiving a lot of attention as regulators of cellular activity. Previously, we proposed a novel screening system for intracellular functional peptides; it combined a photo-cleavable peptide array system with cell-penetrating peptides (CPPs). Various peptides can be delivered into cells and intracellular functions of the peptides can be assayed by means of our system. The aim of the present study was to demonstrate that the proposed screening system can be used for assessing the intracellular activity of peptides. The cell death-inducing peptide (LNLISKLF) identified in a mitochondria-targeting domain (MTD) of the Noxa protein served as an original peptide sequence for screening of peptides with higher activity via modification of the peptide sequence. We obtained 4 peptides with higher activity, in which we substituted serine (S) at the fifth position with phenylalanine (F), valine (V), tryptophan (W), or tyrosine (Y). During analysis of the mechanism of action, the modified peptides induced an increase in intracellular calcium concentration, which was caused by the treatment with the original peptide. Higher capacity for cell death induction by the modified peptides may be caused by increased hydrophobicity or an increased number of aromatic residues. Thus, the present work suggests that the intracellular activity of peptides can be assessed using the proposed screening system. It could be used for identifying intracellular functional peptides with higher activity through comprehensive screening. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. A Lyapunov Function Based Remedial Action Screening Tool Using Real-Time Data

    Energy Technology Data Exchange (ETDEWEB)

    Mitra, Joydeep [Michigan State Univ., East Lansing, MI (United States); Ben-Idris, Mohammed [Univ. of Nevada, Reno, NV (United States); Faruque, Omar [Florida State Univ., Tallahassee, FL (United States); Backhaus, Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Deb, Sidart [LCG Consulting, Los Altos, CA (United States)

    2016-03-30

    This report summarizes the outcome of a research project that comprised the development of a Lyapunov function based remedial action screening tool using real-time data (L-RAS). The L-RAS is an advanced computational tool that is intended to assist system operators in making real-time redispatch decisions to preserve power grid stability. The tool relies on screening contingencies using a homotopy method based on Lyapunov functions to avoid, to the extent possible, the use of time domain simulations. This enables transient stability evaluation at real-time speed without the use of massively parallel computational resources. The project combined the following components. 1. Development of a methodology for contingency screening using a homotopy method based on Lyapunov functions and real-time data. 2. Development of a methodology for recommending remedial actions based on the screening results. 3. Development of a visualization and operator interaction interface. 4. Testing of screening tool, validation of control actions, and demonstration of project outcomes on a representative real system simulated on a Real-Time Digital Simulator (RTDS) cluster. The project was led by Michigan State University (MSU), where the theoretical models including homotopy-based screening, trajectory correction using real-time data, and remedial action were developed and implemented in the form of research-grade software. Los Alamos National Laboratory (LANL) contributed to the development of energy margin sensitivity dynamics, which constituted a part of the remedial action portfolio. Florida State University (FSU) and Southern California Edison (SCE) developed a model of the SCE system that was implemented on FSU's RTDS cluster to simulate real-time data that was streamed over the internet to MSU where the L-RAS tool was executed and remedial actions were communicated back to FSU to execute stabilizing controls on the simulated system. LCG Consulting developed the visualization

  19. The current status and future prospects of breast cancer screening using ultrasonography at our facility

    International Nuclear Information System (INIS)

    Morikubo, Hiroshi; Ichimura, Miyuki; Abe, Satoko

    2011-01-01

    We report the results obtained by breast cancer screening of the general population using both ultrasonography and mammography conducted by the Tochigi Public Health Service Association. An investigation of breast cancer screening carried out on approximately 140,000 participants between 2000 and 2007 showed that ultrasonography and mammography are remarkably complementary for detection of breast cancer, particularly for women in their 40s and 50s, and that each modality improves the sensitivity of breast cancer detection by approximately 20%. The following issues are pivotal for establishing a breast cancer ultrasonography screening system that is able to maintain high precision and adequate efficiency: technical training of sonographers and physicians who must interpret the sonographic images, quality control of equipment, and an interpretation system that allows previous sonographs to be used as a reference. In independent combined screening systems using ultrasonography and mammography, the high recall rate becomes an issue. Comparative interpretation of sonographic images with previous sonographs is effective for resolving this. However, hopes abound for a comprehensive assessment system that allows simultaneous imaging and interpretation of both ultrasonography and mammography. (author)

  20. The current child and adolescent health screening system: an assessment and proposal for an early and periodic check-up program

    Directory of Open Access Journals (Sweden)

    Baik-Lin Eun

    2010-03-01

    Full Text Available Purpose : Recent changes in the population structure of Korea, such as rapid decline in birth rate and exponential increase in old-aged people, prompted us to prepare a new health improvement program in children and adolescents. Methods : We reviewed current health screenings applied for children and adolescents in Korea and other developed countries. We collected and reviewed population-based data focused on mortality and morbidity, and other health-related statistical data. We generated problem lists in current systems and developed new principles. Results : Current health screening programs for children and adolescents were usually based on laboratory tests, such as blood tests, urinalysis, and radiologic tests. Almost all of these programs lacked evidence based on population data or controlled studies. In most developed countries, laboratory tests are used only very selectively, and they usually focus on primary prevention of diseases and health improvement using anticipatory guidance. In Korea, statistics on mortality and morbidity reveal that diseases related to lifestyle, such as obesity and metabolic syndrome, are increasing in all generations. Conclusion : We recommend a periodic health screening program with anticipatory guidance, which is focused on growth and developmental surveillance in infants and children. We no longer recommend old programs that are based on laboratory and radiologic examinations. School health screening programs should also be changed to meet current health issues, such as developing a healthier lifestyle to minimize risk behaviors&#8212;for example, good mental health, balanced nutrition, and more exercise.

  1. Wisdom Appliance Control System

    Science.gov (United States)

    Hendrick; Jheng, Jyun-Teng; Tsai, Chen-Chai; Liou, Jia-Wei; Wang, Zhi-Hao; Jong, Gwo-Jia

    2017-07-01

    Intelligent appliances wisdom involves security, home care, convenient and energy saving, but the home automation system is still one of the core unit, and also using micro-processing electronics technology to centralized and control the home electrical products and systems, such as: lighting, television, fan, air conditioning, stereo, it composed of front-controller systems and back-controller panels, user using front-controller to control command, and then through the back-controller to powered the device.

  2. Model predictive control for a thermostatic controlled system

    DEFF Research Database (Denmark)

    Shafiei, Seyed Ehsan; Rasmussen, Henrik; Stoustrup, Jakob

    2013-01-01

    This paper proposes a model predictive control scheme to provide temperature set-points to thermostatic controlled cooling units in refrigeration systems. The control problem is formulated as a convex programming problem to minimize the overall operating cost of the system. The foodstuff temperat......This paper proposes a model predictive control scheme to provide temperature set-points to thermostatic controlled cooling units in refrigeration systems. The control problem is formulated as a convex programming problem to minimize the overall operating cost of the system. The foodstuff...

  3. Screen-and-treat approaches for cervical cancer prevention in low-resource settings: a randomized controlled trial.

    Science.gov (United States)

    Denny, Lynette; Kuhn, Louise; De Souza, Michelle; Pollack, Amy E; Dupree, William; Wright, Thomas C

    2005-11-02

    Non-cytology-based screen-and-treat approaches for cervical cancer prevention have been developed for low-resource settings, but few have directly addressed efficacy. To determine the safety and efficacy of 2 screen-and-treat approaches for cervical cancer prevention that were designed to be more resource-appropriate than conventional cytology-based screening programs. Randomized clinical trial of 6555 nonpregnant women, aged 35 to 65 years, recruited through community outreach and conducted between June 2000 and December 2002 at ambulatory women's health clinics in Khayelitsha, South Africa. All patients were screened using human papillomavirus (HPV) DNA testing and visual inspection with acetic acid (VIA). Women were subsequently randomized to 1 of 3 groups: cryotherapy if she had a positive HPV DNA test result; cryotherapy if she had a positive VIA test result; or to delayed evaluation. Biopsy-confirmed high-grade cervical cancer precursor lesions and cancer at 6 and 12 months in the HPV DNA and VIA groups compared with the delayed evaluation (control) group; complications after cryotherapy. The prevalence of high-grade cervical intraepithelial neoplasia and cancer (CIN 2+) was significantly lower in the 2 screen-and-treat groups at 6 months after randomization than in the delayed evaluation group. At 6 months, CIN 2+ was diagnosed in 0.80% (95% confidence interval [CI], 0.40%-1.20%) of the women in the HPV DNA group and 2.23% (95% CI, 1.57%-2.89%) in the VIA group compared with 3.55% (95% CI, 2.71%-4.39%) in the delayed evaluation group (Pcryotherapy, major complications were rare. Both screen-and-treat approaches are safe and result in a lower prevalence of high-grade cervical cancer precursor lesions compared with delayed evaluation at both 6 and 12 months. Trial Registration http://clinicaltrials.gov Identifier: NCT00233727.

  4. Screen-time Weight-loss Intervention Targeting Children at Home (SWITCH: A randomized controlled trial study protocol

    Directory of Open Access Journals (Sweden)

    Tsai Midi

    2011-06-01

    Full Text Available Abstract Background Approximately one third of New Zealand children and young people are overweight or obese. A similar proportion (33% do not meet recommendations for physical activity, and 70% do not meet recommendations for screen time. Increased time being sedentary is positively associated with being overweight. There are few family-based interventions aimed at reducing sedentary behavior in children. The aim of this trial is to determine the effects of a 24 week home-based, family oriented intervention to reduce sedentary screen time on children's body composition, sedentary behavior, physical activity, and diet. Methods/Design The study design is a pragmatic two-arm parallel randomized controlled trial. Two hundred and seventy overweight children aged 9-12 years and primary caregivers are being recruited. Participants are randomized to intervention (family-based screen time intervention or control (no change. At the end of the study, the control group is offered the intervention content. Data collection is undertaken at baseline and 24 weeks. The primary trial outcome is child body mass index (BMI and standardized body mass index (zBMI. Secondary outcomes are change from baseline to 24 weeks in child percentage body fat; waist circumference; self-reported average daily time spent in physical and sedentary activities; dietary intake; and enjoyment of physical activity and sedentary behavior. Secondary outcomes for the primary caregiver include change in BMI and self-reported physical activity. Discussion This study provides an excellent example of a theory-based, pragmatic, community-based trial targeting sedentary behavior in overweight children. The study has been specifically designed to allow for estimation of the consistency of effects on body composition for Māori (indigenous, Pacific and non-Māori/non-Pacific ethnic groups. If effective, this intervention is imminently scalable and could be integrated within existing weight

  5. Screening for Antifibrotic Compounds Using High Throughput System Based on Fluorescence Polarization

    Directory of Open Access Journals (Sweden)

    Branko Stefanovic

    2014-04-01

    Full Text Available Fibroproliferative diseases are one of the leading causes of death worldwide. They are characterized by reactive fibrosis caused by uncontrolled synthesis of type I collagen. There is no cure for fibrosis and development of therapeutics that can inhibit collagen synthesis is urgently needed. Collagen α1(I mRNA and α2(I mRNA encode for type I collagen and they have a unique 5' stem-loop structure in their 5' untranslated regions (5'SL. Collagen 5'SL binds protein LARP6 with high affinity and specificity. The interaction between LARP6 and the 5'SL is critical for biosynthesis of type I collagen and development of fibrosis in vivo. Therefore, this interaction represents is an ideal target to develop antifibrotic drugs. A high throughput system to screen for chemical compounds that can dissociate LARP6 from 5'SL has been developed. It is based on fluorescence polarization and can be adapted to screen for inhibitors of other protein-RNA interactions. Screening of 50,000 chemical compounds yielded a lead compound that can inhibit type I collagen synthesis at nanomolar concentrations. The development, characteristics, and critical appraisal of this assay are presented.

  6. A Web-based telemedicine system for diabetic retinopathy screening using digital fundus photography.

    Science.gov (United States)

    Wei, Jack C; Valentino, Daniel J; Bell, Douglas S; Baker, Richard S

    2006-02-01

    The purpose was to design and implement a Web-based telemedicine system for diabetic retinopathy screening using digital fundus cameras and to make the software publicly available through Open Source release. The process of retinal imaging and case reviewing was modeled to optimize workflow and implement use of computer system. The Web-based system was built on Java Servlet and Java Server Pages (JSP) technologies. Apache Tomcat was chosen as the JSP engine, while MySQL was used as the main database and Laboratory of Neuro Imaging (LONI) Image Storage Architecture, from the LONI-UCLA, as the platform for image storage. For security, all data transmissions were carried over encrypted Internet connections such as Secure Socket Layer (SSL) and HyperText Transfer Protocol over SSL (HTTPS). User logins were required and access to patient data was logged for auditing. The system was deployed at Hubert H. Humphrey Comprehensive Health Center and Martin Luther King/Drew Medical Center of Los Angeles County Department of Health Services. Within 4 months, 1500 images of more than 650 patients were taken at Humphrey's Eye Clinic and successfully transferred to King/Drew's Department of Ophthalmology. This study demonstrates an effective architecture for remote diabetic retinopathy screening.

  7. System control and communication

    International Nuclear Information System (INIS)

    Bindner, H.; Oestergaard, J.

    2005-01-01

    Rapid and ongoing development in the energy sector has consequences for system control at all levels. In relation to system control and communication the control system is challenged in five important ways: 1) Expectations for security of supply, robustness and vulnerability are becoming more stringent, and the control system plays a big part in meeting these expectations. 2) Services are becoming increasingly based on markets that involve the transmission system operators (TSOs), generators and distribution companies. Timely, accurate and secure communication is essential to the smooth running of the markets. 3) Adding large amounts of renewable energy (RE) to the mix is a challenge for control systems because of the intermittent availability of many RE sources. 4) Increasing the number of active components in the system, such as small CHP plants, micro-CHP and intelligent loads, means that the system control will be much more complex. 5) In the future it is likely that power, heat, gas, transport and communication systems will be tighter coupled and interact much more. (au)

  8. Decision aid on breast cancer screening reduces attendance rate: results of a large-scale, randomized, controlled study by the DECIDEO group

    Science.gov (United States)

    Bourmaud, Aurelie; Soler-Michel, Patricia; Oriol, Mathieu; Regnier, Véronique; Tinquaut, Fabien; Nourissat, Alice; Bremond, Alain; Moumjid, Nora; Chauvin, Franck

    2016-01-01

    Controversies regarding the benefits of breast cancer screening programs have led to the promotion of new strategies taking into account individual preferences, such as decision aid. The aim of this study was to assess the impact of a decision aid leaflet on the participation of women invited to participate in a national breast cancer screening program. This Randomized, multicentre, controlled trial. Women aged 50 to 74 years, were randomly assigned to receive either a decision aid or the usual invitation letter. Primary outcome was the participation rate 12 months after the invitation. 16 000 women were randomized and 15 844 included in the modified intention-to-treat analysis. The participation rate in the intervention group was 40.25% (3174/7885 women) compared with 42.13% (3353/7959) in the control group (p = 0.02). Previous attendance for screening (RR = 6.24; [95%IC: 5.75-6.77]; p < 0.0001) and medium household income (RR = 1.05; [95%IC: 1.01-1.09]; p = 0.0074) were independently associated with attendance for screening. This large-scale study demonstrates that the decision aid reduced the participation rate. The decision aid activate the decision making process of women toward non-attendance to screening. These results show the importance of promoting informed patient choices, especially when those choices cannot be anticipated. PMID:26883201

  9. Confidence from uncertainty - A multi-target drug screening method from robust control theory

    Directory of Open Access Journals (Sweden)

    Petzold Linda R

    2010-11-01

    Full Text Available Abstract Background Robustness is a recognized feature of biological systems that evolved as a defence to environmental variability. Complex diseases such as diabetes, cancer, bacterial and viral infections, exploit the same mechanisms that allow for robust behaviour in healthy conditions to ensure their own continuance. Single drug therapies, while generally potent regulators of their specific protein/gene targets, often fail to counter the robustness of the disease in question. Multi-drug therapies offer a powerful means to restore disrupted biological networks, by targeting the subsystem of interest while preventing the diseased network from reconciling through available, redundant mechanisms. Modelling techniques are needed to manage the high number of combinatorial possibilities arising in multi-drug therapeutic design, and identify synergistic targets that are robust to system uncertainty. Results We present the application of a method from robust control theory, Structured Singular Value or μ- analysis, to identify highly effective multi-drug therapies by using robustness in the face of uncertainty as a new means of target discrimination. We illustrate the method by means of a case study of a negative feedback network motif subject to parametric uncertainty. Conclusions The paper contributes to the development of effective methods for drug screening in the context of network modelling affected by parametric uncertainty. The results have wide applicability for the analysis of different sources of uncertainty like noise experienced in the data, neglected dynamics, or intrinsic biological variability.

  10. A temperature-tolerant multiplex elements and genes screening system for genetically modified organisms based on dual priming oligonucleotide primers and capillary electrophoresis.

    Science.gov (United States)

    Fu, Wei; Wei, Shuang; Wang, Chenguang; Du, Zhixin; Zhu, Pengyu; Wu, Xiyang; Wu, Gang; Zhu, Shuifang

    2017-08-15

    High throughput screening systems are the preferred solution to meet the urgent requirement of increasing number of genetically modified organisms (GMOs). In this study, we have successfully developed a multiplex GMO element screening system with dual priming oligonucleotide (DPO) primers. This system can detect the cauliflower mosaic virus 35S (CaMV 35S), terminator of nopaline synthase gene (NOS), figwort mosaic virus 35S (FMV 35S) promoter, neomycin phosphotransferaseII (NPTII), Bt Cry 1Ab, phosphinothricin acetyltransferase genes (bar) and Streptomyces viridochromogenes (pat) simultaneously, which covers more than 90% of all authorized GMO species worldwide. This system exhibits a high tolerance to annealing temperatures, high specificity and a limit of detection equal to conventional PCR. A total of 214 samples from markets, national entry-exit agencies, the Institute for Reference Materials and Measurement (IRMM) and the American Oil Chemists' Society (AOCS) were also tested for applicability. This screening system is therefore suitable for GMO screening. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Trends in screening mammograms for women 50 years of age and older - behavioral risk factor surveillance system, 1987

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    To assess whether the media attention to breast cancer screening and the promotional efforts in 1987 were paralleled by increases in screening of women greater than or equal to 50 years of age, CDC analyzed data from 33 states that participated in the 1987 Behavioral Risk Factor Surveillance System (BRFSS)

  12. Experimental study on image quality when using screens in mammography

    International Nuclear Information System (INIS)

    Maurer, H.J.; Goos, F.

    1979-01-01

    1) Different types of screens and X-ray films have been investigated using a Kodak mamma-phantom I.T.O. 745 and compared with conventional non screen industrial film radiography. 2) Dosisreduction by using screens depends on the used film/screen system. It is possible to reach a relation of 1:10. 3) The information depends on type of screen and of type of film. Therefore, it is possible to reach the information of non screen industrial film radiographs. 4) A suitable film/screen system allows without loss of any diagnostic information to replace non screen industrial films needing a high exposure dosis by a film/screen system needing decreased dosis. (orig.) [de

  13. Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study

    Science.gov (United States)

    Chen, Ying-Hsien; Hung, Chi-Sheng; Huang, Ching-Chang; Hung, Yu-Chien

    2017-01-01

    Background Atrial fibrillation (AF) is a common form of arrhythmia that is associated with increased risk of stroke and mortality. Detecting AF before the first complication occurs is a recognized priority. No previous studies have examined the feasibility of undertaking AF screening using a telehealth surveillance system with an embedded cloud-computing algorithm; we address this issue in this study. Objective The objective of this study was to evaluate the feasibility of AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm. Methods We conducted a prospective AF screening study in a nonmetropolitan area using a single-lead electrocardiogram (ECG) recorder. All ECG measurements were reviewed on the telehealth surveillance system and interpreted by the cloud-computing algorithm and a cardiologist. The process of AF screening was evaluated with a satisfaction questionnaire. Results Between March 11, 2016 and August 31, 2016, 967 ECGs were recorded from 922 residents in nonmetropolitan areas. A total of 22 (2.4%, 22/922) residents with AF were identified by the physician’s ECG interpretation, and only 0.2% (2/967) of ECGs contained significant artifacts. The novel cloud-computing algorithm for AF detection had a sensitivity of 95.5% (95% CI 77.2%-99.9%) and specificity of 97.7% (95% CI 96.5%-98.5%). The overall satisfaction score for the process of AF screening was 92.1%. Conclusions AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm is feasible. PMID:28951384

  14. Analogue to digital upgrade project-boiler feedwater control system for Bruce Power nuclear units 1 & 2

    International Nuclear Information System (INIS)

    Long, R.

    2012-01-01

    Bruce Power Nuclear Generating Station A, “Bruce A” is in the final stages of its Restart Project. This capital project will see a large scale rehabilitation of Units 1 and 2 resulting in addition of 1500MW of safe, reliable, clean electricity to the Ontario grid. Restart Project Scope 375, Boiler Feedwater Controls Upgrade was sanctioned to replace obsolete analog devices with a modern digital control system. This project replaced the existing Foxboro H Line analog controls which comprised of 81 individual control modules and support instrumentation. The replacement system was a Triconex Triple Modular Redundant PLC which interfaces with two redundant touch screen monitors. The upgraded digital system incorporates the following controls: 1. Boiler Level Control Loops 2. Dearator Level Control Loops 3. Dearator Pressure Control Loops 4. Boiler Feedwater Recirculation Flow Control Loops A number of technical challenges were addressed when installing a new digital system within the existing plant configuration. Interfaces to new, old and refurbished field devices must be understood as well as implications of connecting to the plant’s Digital Control Computers (DCC’s) and newly installed Steam Generators. The overall project involved many stakeholders to address various requirements from conceptual / design stage through procurement, construction, commissioning and return to service. In addition, the project highlighted the unique requirements found in Nuclear Industry with respect to Human Factors and Software Quality Assurance. (author)

  15. Implementing a computer-assisted telephone interview (CATI) system to increase colorectal cancer screening: a process evaluation.

    Science.gov (United States)

    White, Mary Jo; Stark, Jennifer R; Luckmann, Roger; Rosal, Milagros C; Clemow, Lynn; Costanza, Mary E

    2006-06-01

    Computer-assisted telephone interviewing (CATI) systems used by telephone counselors (TCs) may be efficient mechanisms to counsel patients on cancer and recommended preventive screening tests in order to extend a primary care provider's reach to his/her patients. The implementation process of such a system for promoting colorectal (CRC) cancer screening using a computer-assisted telephone interview (CATI) system is reported in this paper. The process evaluation assessed three components of the intervention: message production, program implementation and audience reception. Of 1181 potentially eligible patients, 1025 (87%) patients were reached by the TCs and 725 of those patients (71%) were eligible to receive counseling. Five hundred eighty-two (80%) patients agreed to counseling. It is feasible to design and use CATI systems for prevention counseling of patients in primary care practices. CATI systems have the potential of being used as a referral service by primary care providers and health care organizations for patient education.

  16. Experience with the european quality assurance guidelines for digital mammography systems in a national screening programme

    International Nuclear Information System (INIS)

    McCullagh, J.; Keavey, E.; Egan, G.; Phelan, N.

    2013-01-01

    The transition to a fully digital breast screening programme, utilising three different full-field digital mammography (FFDM) systems has presented many challenges to the implementation of the European guidelines for physico-technical quality assurance (QA) testing. An analysis of the QA results collected from the FFDM systems in the screening programme over a 2-y period indicates that the three different systems have similar QA performances. Generally, the same tests were failed by all systems and failure rates were low. The findings provide some assurance that the QA guidelines are being correctly implemented. They also suggest that there is more scope for the development of the relevance of the guidelines with respect to modern FFDM systems. This study has also shown that a summary review of the QA data can be achieved by simple organisation of the QA data storage and by automation of data query and retrieval using commonly available software. (authors)

  17. Plug-and-Play Control – Modifying Control Systems Online

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, K; Stoustrup, Jakob

    2013-01-01

    Often, when new sensor or actuator hardware be- comes available for use in a control system, it is desirable to retain the existing control system and apply the new control capabilities in a gradual fashion rather than decommissioning the entire existing system and replacing it with an altogether...... new control system. However, this requires that the existing controller remains in action, and the new control law component is added to the existing system. This paper formally introduces the concept of Plug-and-Play control and proposes two different methods of introducing new control components...

  18. Effect of CT screening on smoking habits at 1-year follow-up in the Danish Lung Cancer Screening Trial (DLCST)

    DEFF Research Database (Denmark)

    Ashraf, H; Tønnesen, P; Holst Pedersen, J

    2008-01-01

    BACKGROUND: The effect of low-dose CT screening for lung cancer on smoking habits has not been reported in large randomised controlled trials. METHODS: This study evaluated the effect on smoking habits of screening with low-dose CT at 1-year follow up in the Danish Lung Cancer Screening Trial...... pack years. Smoking habits were determined at baseline and at annual screening. Smoking status was verified using exhaled carbon monoxide levels. Lung function tests, nicotine dependency and motivation to quit smoking were assessed. Quit rates and relapse rates were determined at 1-year follow...... (DLCST), a 5-year randomised controlled trial comprising 4104 subjects; 2052 subjects received annual low-dose CT scan (CT group) and 2052 received no intervention (control group). Participants were healthy current and former smokers (>4 weeks since smoking cessation) with a tobacco consumption of >20...

  19. Magnetic Frequency Response of HL-LHC Beam Screens

    Energy Technology Data Exchange (ETDEWEB)

    Morrone, M. [CERN; Martino, M. [CERN; De Maria, R. [CERN; Fitterer, M. [Fermilab; Garion, C. [CERN

    2017-10-12

    Magnetic fields used to control particle beams in accelerators are usually controlled by regulating the electrical current of the power converters. In order to minimize lifetime degradation and ultimately luminosity loss in circular colliders, current-noise is a highly critical figure of merit of power converters, in particular for magnets located in areas with high beta-function, like the High Luminosity Large Hadron Collider (HL-LHC) insertions. However, what is directly acting upon the beam is the magnetic field and not the current of the power converter, which undergoes several frequency-dependent transformations until the desired magnetic field, seen by the beam, is obtained. Beam screens are very rarely considered when assessing or specifying the noise figure of merit, but their magnetic frequency response is such that they realize relatively effective low pass filtering of the magnetic field produced by the system magnet-power converter. This work aims at filling this gap by quantifying the expected impact of different beam screen layouts for the most relevant HL-LHC insertion magnets. A welldefined post-processing technique is used to derive the frequency response of the different multipoles from multi-physics Finite Element Method (FEM) simulation results. In addition, a well approximated analytical formula for the low-frequency range of multi-layered beam screens is presented.

  20. Standardized assessment of infrared thermographic fever screening system performance

    Science.gov (United States)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  1. Systems of support to increase colorectal cancer screening and follow-up rates (SOS): design, challenges, and baseline characteristics of trial participants.

    Science.gov (United States)

    Green, Beverly B; Wang, C Y; Horner, Kathryn; Catz, Sheryl; Meenan, Richard T; Vernon, Sally W; Carrell, David; Chubak, Jessica; Ko, Cynthia; Laing, Sharon; Bogart, Andy

    2010-11-01

    Screening decreases colorectal cancer (CRC) morbidity and mortality, yet remains underutilized. Screening breakdowns arise from lack of uptake and failure to follow-up after a positive screening test. Systems of support to increase colorectal cancer screening and follow-up (SOS) is a randomized trial designed to increase: (1) CRC screening and (2) follow-up of positive screening tests. The Chronic Care Model and the Preventive Health Model inform study design. The setting is a large nonprofit healthcare organization. In part-1 study, patients age 50-75 due for CRC screening are randomized to one of 4 study conditions. Arm 1 receives usual care. Arm 2 receives automated support (mailed information about screening choices and fecal occult blood tests (FOBT)). Arm 3 receives automated and assisted support (a medical assistant telephone call). Arm 4 receives automated, assisted, and care management support (a registered nurse provides behavioral activation and coordination of care). In part-2, study patients with a positive FOBT or adenomas on flexible sigmoidoscopy are randomized to receive either usual care or nurse care management. Primary outcomes are: 1) the proportion with CRC screening, 2) the proportion with a complete diagnostic evaluation after a positive screening test. We sent recruitment letters to 15,414 patients and 4675 were randomized. Randomly assigned treatment groups were similar in age, sex, race, education, self-reported health, and CRC screening history. We will determine the effectiveness and cost effectiveness of stepped increases in systems of support to increase CRC screening and follow-up after a positive screening test over 2years. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. Effects of a health education and telephone counseling program on patients with a positive fecal occult blood test result for colorectal cancer screening: A randomized controlled trial.

    Science.gov (United States)

    Chiu, Hui-Chuan; Hung, Hsin-Yuan; Lin, Hsiu-Chen; Chen, Shu-Ching

    2017-10-01

    Our purpose was to evaluate the effects of a health education and telephone counseling program on knowledge and attitudes about colorectal cancer and screening and the psychological impact of positive screening results. A randomized controlled trial was conducted with 2 groups using a pretest and posttest measures design. Patients with positive colorectal cancer screening results were selected and randomly assigned to an experimental (n = 51) or control (n = 51) group. Subjects in the experimental group received a health education and telephone counseling program, while the control group received routine care only. Patients were assessed pretest before intervention (first visit to the outpatient) and posttest at 4 weeks after intervention (4 weeks after first visit to the outpatient). Patients in the experimental group had a significantly better level of knowledge about colorectal cancer and the psychological impact of a positive screening result than did the control group. Analysis of covariance revealed that the health education and telephone counseling program had a significant main effect on colorectal cancer knowledge. A health education and telephone counseling program can improve knowledge about colorectal cancer and about the psychological impact in patients with positive colorectal cancer screening results. The health education and telephone counseling program is an easy, simple, and convenient method of improving knowledge, improving attitudes, and alleviating psychological distress in patients with positive colorectal cancer screening results, and this program can be expanded to other types of cancer screening. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Screening of wheat endophytes as biological control agents against Fusarium head blight using two different in vitro tests.

    Science.gov (United States)

    Comby, Morgane; Gacoin, Marie; Robineau, Mathilde; Rabenoelina, Fanja; Ptas, Sébastien; Dupont, Joëlle; Profizi, Camille; Baillieul, Fabienne

    2017-09-01

    In order to find biological control agents (BCAs) for the management of Fusarium head blight (FHB), a major disease on wheat crops worldwide, 86 microorganisms isolated from inner tissues of wheat plants were discriminated for their ability to inhibit the growth of Fusarium graminearum and Fusarium culmorum by in vitro dual culture assays. A group of 22 strains appeared very effective to inhibit F. graminearum (inhibition of 30-51%) and they were also globally effective in controlling F. culmorum (inhibition of 15-53%). Further evaluation of a subselection of strains by screening on detached spikelets in vitro confirmed three species, namely Phoma glomerata, Aureobasidium proteae and Sarocladium kiliense, that have not yet been reported for their efficacy against Fusarium spp., indicating that looking for BCAs toward FHB among wheat endophytes proved to be promising. The efficacy of some strains turned out different between both in vitro screening approaches, raising the importance of finding the most appropriate screening approach for the search of BCAs. This study pointed out the interest of the test on detached wheat spikelets that provided information about a potential pathogenicity, the growth capacity and efficacy of the endophyte strains on the targeted plant, before testing them on whole plants. Copyright © 2017 Elsevier GmbH. All rights reserved.

  4. Networked control of microgrid system of systems

    Science.gov (United States)

    Mahmoud, Magdi S.; Rahman, Mohamed Saif Ur; AL-Sunni, Fouad M.

    2016-08-01

    The microgrid has made its mark in distributed generation and has attracted widespread research. However, microgrid is a complex system which needs to be viewed from an intelligent system of systems perspective. In this paper, a network control system of systems is designed for the islanded microgrid system consisting of three distributed generation units as three subsystems supplying a load. The controller stabilises the microgrid system in the presence of communication infractions such as packet dropouts and delays. Simulation results are included to elucidate the effectiveness of the proposed control strategy.

  5. Tuberculosis screening among Bolivian sex workers and their children

    Directory of Open Access Journals (Sweden)

    Silvia S. Chiang

    2015-06-01

    Full Text Available Bolivian sex workers were more likely than other employed women to report tuberculosis screening only if they reported HIV screening. Of all women with household tuberculosis exposure, <40% reported screening for themselves or their children. Coupling tuberculosis screening with sex workers’ mandatory HIV screenings may be a cost-efficient disease-control strategy.

  6. Screening of tomato varieties for fruit tree based Agroforestry system

    Directory of Open Access Journals (Sweden)

    J. Hossain

    2014-12-01

    Full Text Available An experiment was conducted with four tomato varieties under a six year old orchard was accomplished at the Bangabandhu Sheikh Mujibur Rahman Agricultural University (BSMRAU research farm during October 2011 to April 2012. The experiment was laid out in a Randomized Complete Block Design with three replications. Four tomato varieties (BARI Tomato 2, BARI Tomato 8, BARI Tomato 14 and BARI Tomato 15 were grown under guava, mango, olive and control. Results showed that light availability in control plot (999.75 μ mol m-2s-1 was remarkably higher over fruit tree based agroforestry systems and it was 58.8, 43.9 and 31.5% of the control for guava, mango and olive based systems, respectively. The shortest tomato plant was observed in olive based system (54.91 cm, while the tallest plant was observed in mango based system (60.09 cm. The highest SPAD value and number of primary branches per plant was recorded in control plot. Fruit length, fruit girth was found lowest in olive based system. The highest yield (34.06 t ha-1 was recorded in control plot while the lowest yield (10.26 t ha-1 was recorded in olive based system. The economic performance of fruit tree based tomato production system showed that both the net return and BCR of mango and guava based system was higher over control and olive based system. The contents of organic carbon, nitrogen, available phosphorus, potassium and sulfur of before experimentation soil were slightly higher in fruit tree based agroforestry systems than the control. After experimentation, nutrient elements in soil were found increased slightly than initial soils. Fruit tree based agroforestry systems could be ranked based on the economic performance as mango> guava> control> olive based system with BARI Tomato 15, BARI Tomato 2, BARI Tomato 14 and BARI Tomato 8, respectively.

  7. Colorectal cancer screening

    OpenAIRE

    McLoughlin, Monica Ramona

    2008-01-01

    Colorectal cancer is a major public health burden and is the most common cause of mortality from cancer in Europe. Over the last two decades robust evidence from randomised clinical trials and case-control series have confirmed that the mortality from colorectal cancer can be reduced by screening. The challenge over the next decade is how to implement this in clinical practice. This is what we set out to answer with this thesis. Not all individuals are equal when it comes to screening and tho...

  8. A comparison of two different T-grain films in rare-earth screens with a standard film-screen combination for intravenous pyelography and bone examinations

    International Nuclear Information System (INIS)

    Logan, H.; Daly, L.; Masterson, J.

    1989-01-01

    T-grain film is claimed to give significantly improved image quality, allowing use of faster screens without loss of quality, thus reducing radiation dose. We tested this claim for two systems. In each case comparison was made with our usual screen-film combination, Agfa Curix RP1 film with Kodak Xomatic Regular screens (a nominally 200 speed system). The systems tested were Kodak TMatG in Kodak Lanex Medium screens (300 speed) and Agfa STG in Kodak Lanex Regular screens (400 speed). The Agfa STG-Lanex Regular system performed less well than the standard system for intravenous pyelograms (IVPs), bones and soft-tissue detail. Its speed advantage was not apparent below 70 kV. The Kodak TMatG-Lanex Medium system was better than the standard system for IVPs but not as good for bones. It gave virtually no speed advantage below 90 kV. Kodak T-grain film in a medium-speed, rare-earth screen was found to be better than the standard system for IVPs. Agfa T-grain film in a fast rare-earth screen was unsatisfactory for IVPs. Neither combination was as good as the standard system for bones. (author)

  9. Controlling chaotic systems via nonlinear feedback control

    International Nuclear Information System (INIS)

    Park, Ju H.

    2005-01-01

    In this article, a new method to control chaotic systems is proposed. Using Lyapunov method, we design a nonlinear feedback controller to make the controlled system be stabilized. A numerical example is given to illuminate the design procedure and advantage of the result derived

  10. A high-throughput screening system for barley/powdery mildew interactions based on automated analysis of light micrographs.

    Science.gov (United States)

    Ihlow, Alexander; Schweizer, Patrick; Seiffert, Udo

    2008-01-23

    To find candidate genes that potentially influence the susceptibility or resistance of crop plants to powdery mildew fungi, an assay system based on transient-induced gene silencing (TIGS) as well as transient over-expression in single epidermal cells of barley has been developed. However, this system relies on quantitative microscopic analysis of the barley/powdery mildew interaction and will only become a high-throughput tool of phenomics upon automation of the most time-consuming steps. We have developed a high-throughput screening system based on a motorized microscope which evaluates the specimens fully automatically. A large-scale double-blind verification of the system showed an excellent agreement of manual and automated analysis and proved the system to work dependably. Furthermore, in a series of bombardment experiments an RNAi construct targeting the Mlo gene was included, which is expected to phenocopy resistance mediated by recessive loss-of-function alleles such as mlo5. In most cases, the automated analysis system recorded a shift towards resistance upon RNAi of Mlo, thus providing proof of concept for its usefulness in detecting gene-target effects. Besides saving labor and enabling a screening of thousands of candidate genes, this system offers continuous operation of expensive laboratory equipment and provides a less subjective analysis as well as a complete and enduring documentation of the experimental raw data in terms of digital images. In general, it proves the concept of enabling available microscope hardware to handle challenging screening tasks fully automatically.

  11. Applied Control Systems Design

    CERN Document Server

    Mahmoud, Magdi S

    2012-01-01

    Applied Control System Design examines several methods for building up systems models based on real experimental data from typical industrial processes and incorporating system identification techniques. The text takes a comparative approach to the models derived in this way judging their suitability for use in different systems and under different operational circumstances. A broad spectrum of control methods including various forms of filtering, feedback and feedforward control is applied to the models and the guidelines derived from the closed-loop responses are then composed into a concrete self-tested recipe to serve as a check-list for industrial engineers or control designers. System identification and control design are given equal weight in model derivation and testing to reflect their equality of importance in the proper design and optimization of high-performance control systems. Readers’ assimilation of the material discussed is assisted by the provision of problems and examples. Most of these e...

  12. The Japanese Guidelines for Breast Cancer Screening.

    Science.gov (United States)

    Hamashima, Chisato; Hamashima C, Chisato; Hattori, Masakazu; Honjo, Satoshi; Kasahara, Yoshio; Katayama, Takafumi; Nakai, Masahiro; Nakayama, Tomio; Morita, Takako; Ohta, Koji; Ohnuki, Koji; Sagawa, Motoyasu; Saito, Hiroshi; Sasaki, Seiju; Shimada, Tomoyuki; Sobue, Tomotaka; Suto, Akihiko

    2016-05-01

    The incidence of breast cancer has progressively increased, making it the leading cause of cancer deaths in Japan. Breast cancer accounts for 20.4% of all new cancers with a reported age-standardized rate of 63.6 per 100 000 women. The Japanese guidelines for breast cancer screening were developed based on a previously established method. The efficacies of mammography with and without clinical breast examination, clinical breast examination and ultrasonography with and without mammography were evaluated. Based on the balance of the benefits and harms, recommendations for population-based and opportunistic screenings were formulated. Five randomized controlled trials of mammographic screening without clinical breast examination were identified for mortality reduction from breast cancer. The overall relative risk for women aged 40-74 years was 0.75 (95% CI: 0.67-0.83). Three randomized controlled trials of mammographic screening with clinical breast examination served as eligible evidence for mortality reduction from breast cancer. The overall relative risk for women aged 40-64 years was 0.87 (95% confidence interval: 0.77-0.98). The major harms of mammographic screening were radiation exposure, false-positive cases and overdiagnosis. Although two case-control studies evaluating mortality reduction from breast cancer were found for clinical breast examination, there was no study assessing the effectiveness of ultrasonography for breast cancer screening. Mammographic screening without clinical breast examination for women aged 40-74 years and with clinical breast examination for women aged 40-64 years is recommended for population-based and opportunistic screenings. Clinical breast examination and ultrasonography are not recommended for population-based screening because of insufficient evidence regarding their effectiveness. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Beliefs Underlying Messages of Anti-Cancer-Screening

    Science.gov (United States)

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro

    2018-02-26

    Background: Cancer screening rates are lower in Japan than in Western countries. Meanwhile, anti-cancer-screening activists take to the internet to spread their messages that cancer screening has little or no efficacy, poses substantial health risks such as side effects from radiation exposure, and that people should forgo cancer screening. We applied a qualitative approach to explore the beliefs underlying the messages of anti-cancer-screening websites, by focusing on perceived value the beliefs provided to those who held them. Methods: We conducted online searches using Google Japan and Yahoo! Japan, targeting websites we classified as “pro,” “anti,” or “neutral” depending on their claims. We applied a dual analytic approach- inductive thematic analysis and deductive interpretative analysis- to the textual data of the anti websites. Results: Of the 88 websites analyzed, five themes that correspond to beliefs were identified: destruction of common knowledge, denial of standard cancer control, education about right cancer control, education about hidden truths, and sense of superiority that only I know the truth. Authors of anti websites ascribed two values (“safety of people” and “self-esteem”) to their beliefs. Conclusion: The beliefs of authors of anti-cancer-screening websites were supposed to be strong. It would be better to target in cancer screening promotion not outright screening refusers but screening hesitant people who are more amenable to changing their attitudes toward screening. The possible means to persuade them were discussed. Creative Commons Attribution License

  14. Expert systems in process control systems

    International Nuclear Information System (INIS)

    Wittig, T.

    1987-01-01

    To illustrate where the fundamental difference between expert systems in classical diagnosis and in industrial control lie, the work of process control instrumentation is used as an example for the job of expert systems. Starting from the general process of problem-solving, two classes of expert systems can be defined accordingly. (orig.) [de

  15. Recruitment for 'A pilot study of randomized controlled trial to evaluate the efficacy of lung cancer screening by thoracic CT'

    International Nuclear Information System (INIS)

    Sagawa, Motoyasu; Tanaka, Makoto; Mizukami, Satoru

    2011-01-01

    The objective of this study was to evaluate the efficacy of lung cancer screening by thoracic computed tomography (CT), a randomized controlled trial was planned in Japan. The randomized trial was designed as follows: participants were randomly assigned into 2 groups, CT group and XP group; XP group would receive 10 times of lung cancer screening by chest x-ray annually for 10 years; smokers in CT group would receive 10 times of lung cancer screening by thoracic CT annually for 10 years; non-smokers in CT group would receive 3 times of lung cancer screening by thoracic CT and 7 times of chest x-ray during 10 years. A pilot study was performed to evaluate the feasibility of the trial. A letter for recruitment to participate in the above trial was mailed to the citizens in Hakui City, who were 50-64 years old and underwent regular lung cancer screening using chest x-ray this year. In the letter we explained that the efficacy of lung cancer screening by thoracic CT had not been proved yet; only half of the participants could undergo thoracic CT screening; thoracic CT screening might cause unfavorable consequences like radiation exposure, false positives or overdiagnosis. Of 329 persons who received the letter of recruitment, 117 replied. After meeting with us for detailed explanation, 111 persons participated in the above randomized trial. The compliance of recruitment is high (approximately one third) and the above trial may be feasible. (author)

  16. Set up and operation for medical radiation exposure quality control system of health promotion center

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Kim, Jung Min [Korea University,Seoul (Korea, Republic of); Jung, Hae Kyoung [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-03-15

    In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT 357.9 mGy·cm in abdomen and pelvic CT, 572.4 mGy·cm in brain without CT, 55.9 mGy·cm in calcium score/heart CT, screening CT at 54 mGy·cm in chest screening CT(low dose screening CT scan), 284.99 mGy·cm in C-spine CT and 341.85 mGy·cm in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows 274.0 mGy·cm{sup 2} and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

  17. Set up and operation for medical radiation exposure quality control system of health promotion center

    International Nuclear Information System (INIS)

    Kim, Jung Su; Kim, Jung Min; Jung, Hae Kyoung

    2016-01-01

    In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT 357.9 mGy·cm in abdomen and pelvic CT, 572.4 mGy·cm in brain without CT, 55.9 mGy·cm in calcium score/heart CT, screening CT at 54 mGy·cm in chest screening CT(low dose screening CT scan), 284.99 mGy·cm in C-spine CT and 341.85 mGy·cm in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows 274.0 mGy·cm"2 and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure

  18. Malignancies in Patients with Anti-RNA Polymerase III Antibodies and Systemic Sclerosis: Analysis of the EULAR Scleroderma Trials and Research Cohort and Possible Recommendations for Screening.

    Science.gov (United States)

    Lazzaroni, Maria-Grazia; Cavazzana, Ilaria; Colombo, Enrico; Dobrota, Rucsandra; Hernandez, Jasmin; Hesselstrand, Roger; Varju, Cecilia; Nagy, Gabriella; Smith, Vanessa; Caramaschi, Paola; Riccieri, Valeria; Hachulla, Eric; Balbir-Gurman, Alexandra; Chatelus, Emmanuel; Romanowska-Próchnicka, Katarzyna; Araújo, Ana Carolina; Distler, Oliver; Allanore, Yannick; Airò, Paolo

    2017-05-01

    To analyze the characteristics of anti-RNA polymerase III antibodies (anti-RNAP3)- positive patients with systemic sclerosis (SSc) in the European League Against Rheumatism Scleroderma Trials and Research group (EUSTAR) registry with a focus on the risk of cancer and the characteristics of malignancies, and the aim to provide guidelines about potential cancer screening in these patients. (1) Analysis of the EUSTAR database: 4986 patients with information on their anti-RNAP3 status were included. (2) Case-control study: additional retrospective data, including malignancy history, were queried in 13 participating EUSTAR centers; 158 anti-RNAP3+ cases were compared with 199 local anti-RNAP3- controls, matched for sex, cutaneous subset, disease duration, and age at SSc onset. (3) A Delphi exercise was performed by 82 experts to reach consensus for cancer screening in anti-RNAP3+ patients. In the EUSTAR registry, anti-RNAP3 were associated in multivariable analysis with renal crisis and diffuse cutaneous involvement. In the case-control study, anti-RNAP3 were associated with gastric antral vascular ectasia, rapid progression of skin involvement, and malignancies concomitant to SSc onset (OR 7.38, 95% CI 1.61-33.8). When compared with other anti-RNAP3+ patients, those with concomitant malignancies had older age (p < 0.001) and more frequent diffuse cutaneous involvement (p = 0.008). The Delphi exercise highlighted the need for malignancy screening at the time of diagnosis for anti-RNAP3+ patients and tight followup in the following years. Anti-RNAP3+ patients with SSc have a high risk of concomitant malignancy. These results have implications for clinical practice and suggest regular screening for cancer in anti-RNAP3+ patients.

  19. Modernization of turbine control system and reactor control system in Almaraz 1 and 2

    International Nuclear Information System (INIS)

    Pulido, C.; Diez, J.; Carrasco, J. A.; Lopez, L.

    2005-01-01

    The replacement of the Turbine Control System and Reactor Control System are part of the Almaraz modernization program for the Instrumentation and Control. For these upgrades Almaraz has selected the Ovation Platform that provides open architecture and easy expansion to other systems, these platforms is highly used in many nuclear and thermal plants around the world. One of the main objective for this project were to minimize the impact on the installation and operation of the plant, for that reason the project is implemented in two phases, Turbine Control upgrade and Reactor Control upgrade. Another important objective was to increase the reliability of the control system making them fully fault tolerant to single failures. The turbine Control System has been installed in Units 1 and 2 while the Reactor Control System will be installed in 2006 and 2007 outages. (Author)

  20. Engineering a vitamin B12 high-throughput screening system by riboswitch sensor in Sinorhizobium meliloti.

    Science.gov (United States)

    Cai, Yingying; Xia, Miaomiao; Dong, Huina; Qian, Yuan; Zhang, Tongcun; Zhu, Beiwei; Wu, Jinchuan; Zhang, Dawei

    2018-05-11

    As a very important coenzyme in the cell metabolism, Vitamin B 12 (cobalamin, VB 12 ) has been widely used in food and medicine fields. The complete biosynthesis of VB 12 requires approximately 30 genes, but overexpression of these genes did not result in expected increase of VB 12 production. High-yield VB 12 -producing strains are usually obtained by mutagenesis treatments, thus developing an efficient screening approach is urgently needed. By the help of engineered strains with varied capacities of VB 12 production, a riboswitch library was constructed and screened, and the btuB element from Salmonella typhimurium was identified as the best regulatory device. A flow cytometry high-throughput screening system was developed based on the btuB riboswitch with high efficiency to identify positive mutants. Mutation of Sinorhizobium meliloti (S. meliloti) was optimized using the novel mutation technique of atmospheric and room temperature plasma (ARTP). Finally, the mutant S. meliloti MC5-2 was obtained and considered as a candidate for industrial applications. After 7 d's cultivation on a rotary shaker at 30 °C, the VB 12 titer of S. meliloti MC5-2 reached 156 ± 4.2 mg/L, which was 21.9% higher than that of the wild type strain S. meliloti 320 (128 ± 3.2 mg/L). The genome of S. meliloti MC5-2 was sequenced, and gene mutations were identified and analyzed. To our knowledge, it is the first time that a riboswitch element was used in S. meliloti. The flow cytometry high-throughput screening system was successfully developed and a high-yield VB 12 producing strain was obtained. The identified and analyzed gene mutations gave useful information for developing high-yield strains by metabolic engineering. Overall, this work provides a useful high-throughput screening method for developing high VB 12 -yield strains.

  1. Digital control system of advanced reactor

    International Nuclear Information System (INIS)

    Peng Huaqing; Zhang Rui; Liu Lixin

    2001-01-01

    This article produced the Digital Control System For Advanced Reactor made by NPIC. This system uses Siemens SIMATIC PCS 7 process control system and includes five control system: reactor power control system, pressurizer level control system, pressurizer pressure control system, steam generator water level control system and dump control system. This system uses three automatic station to realize the function of five control system. Because the safety requisition of reactor is very strict, the system is redundant. The system configuration uses CFC and SCL. the human-machine interface is configured by Wincc. Finally the system passed the test of simulation by using RETRAN 02 to simulate the control object. The research solved the key technology of digital control system of reactor and will be very helpful for the nationalization of digital reactor control system

  2. A Mobile Health Data Collection System for Remote Areas to Monitor Women Participating in a Cervical Cancer Screening Campaign.

    Science.gov (United States)

    Quercia, Kelly; Tran, Phuong Lien; Jinoro, Jéromine; Herniainasolo, Joséa Lea; Viviano, Manuela; Vassilakos, Pierre; Benski, Caroline; Petignat, Patrick

    2018-04-01

    Barriers to efficient cervical cancer screening in low- and medium-income countries include the lack of systematic monitoring of the participants' data. The aim of this study was to assess the feasibility of a mobile health (m-Health) data collection system to facilitate monitoring of women participating to cervical cancer screening campaign. Women aged 30-65 years, participating in a cervical cancer screening campaign in Ambanja, Madagascar, were invited to participate in the study. Cervical Cancer Prevention System, an m-Health application, allows the registration of clinical data, while women are undergoing cervical cancer screening. All data registered in the smartphone were transmitted onto a secure, Web-based platform through the use of an Internet connection. Healthcare providers had access to the central database and could use it for the follow-up visits. Quality of data was assessed by computing the percentage of key data missing. A total of 151 women were recruited in the study. Mean age of participants was 41.8 years. The percentage of missing data for the key variables was less than 0.02%, corresponding to one woman's medical history data, which was not sent to the central database. Technical problems, including transmission of photos, human papillomavirus test results, and pelvic examination data, have subsequently been solved through a system update. The quality of the data was satisfactory and allowed monitoring of cervical cancer screening data of participants. Larger studies evaluating the efficacy of the system for the women's follow-up are needed in order to confirm its efficiency on a long-term scale.

  3. [Application of multiplex PCR for the screening of genotyping system for the rare blood groups Fy(a-), s-,k-,Di(b-) and Js(b-)].

    Science.gov (United States)

    Jiao, Wei; Xie, Li; Li, Hailan; Lan, Jiao; Mo, Zhuning; Yang, Ziji; Liu, Fei; Xiao, Ruiping; He, Yunlei; Ye, Luyi; Zhu, Ziyan

    2014-04-01

    To screen rare blood groups Fy(a-), s-, k-, Di(b-) and Js(b-) in an ethnic Zhuang population. Sequence-specific primers were designed based on single nucleotide polymorphism (SNP) sites of blood group antigens Fy(b) and s. A specific multiplex PCR system I was established. Multiplex PCR system II was applied to detect alleles antigens Di(b), k, Js(b)1910 and Js(b) 2019 at the same time. The two systems was were used to screen for rare blood group antigens in 4490 randomly selected healthy donors of Guangxi Zhuang ethnic origin. We successfully made the multiplex PCR system I. We detected the rare blood group antigens using the two PCR system. There are five Fy(a-), three s(-), two Di(b-) in 4490 Guangxi zhuang random samples. The multiplex PCR system I has achieved good accuracy and stability. With multiplex PCR systems I and II, 4490 samples were screened. Five Fy(a-), three s(-) and two Di(b-) samples were discovered. Multiplex PCR is an effective methods, which can be used for high throughput screening of rare blood groups. The rare blood types of Guangxi Zhuang ethnic origin obtained through the screening can provide valuable information for compatible blood transfusion. Through screening we obtained precious rare blood type materials which can be used to improve the capability of compatible infusion and reduce the transfusion reactions.

  4. Human engineering evaluation of Hamaoka No. 3 advanced control room CRT display system

    International Nuclear Information System (INIS)

    Okajima, Hiroyuki; Ito, Takahiko; Noguchi, Yoshihiro; Kabasawa, Yoshihiko

    1985-01-01

    As the central control board of Hamaoka No. 3 plant, a new type control board was adopted for the purpose of powerfully supporting the general judgement function of operators by processing enormous plant data in the normal operation and at the time of an accident with a computer, and displaying the results on CRT screens in the summarized form. Recently, the evaluation of this new control board was carried out by ergonomical techniques, and it was confirmed that the initial objective has been attained. Besides, the criteria for the ergonomical evaluation of central control boards mainly for CRT display were determined, and the contents of design were able to be systematically evaluated and verified. As the ergonomical design of the central control board, the easy distinction of the function of switches, the easy confirmation of system constitution by mimics, the use of CRTs, the easy identification of operation pilot lamps, alarms, instruments and so on were considered. The central control board consists of the main control board, auxiliary control boards and vertical boards, and 12 CRTs are installed. (Kako, I.)

  5. Integration of the Ovation Based Distributed Turbine Control System into the Existing Process Information System and Full Scope Simulator at NPP Krsko

    International Nuclear Information System (INIS)

    Cicvaric, D.

    2010-01-01

    Programmable Digital Electro Hydraulic System (PDEH) is Turbine Control System (TCS), built on Emerson OVATION Distributed Control System (DCS) platform and installed by the Westinghouse Electric Company at the Krsko Nuclear Power Plant as the replacement for the DEH Mod II turbine control system. Core of the PDEH system consist of three pairs of redundant controllers (ETS, OA/OPC and ATC/MSR) configured for the Turbine Generator (TG) set protection, control and monitoring functions. Existing serial data link between replaced DEH Mod II and Process Information System (PIS) was removed and replaced with redundant bi-directional Ethernet TCP/IP data link via two Data Link servers in client-server architecture configuration. All hardwired signals and some of the important calculated signals are being transferred from PDEH to PIS. Main purpose of PIS data link is trending utilization at the existing PIS workstations with pre-configured trend groups and centralized data archiving. Most of the PDEH display screens (mimics) were also replicated on the PIS platform, so that TG set monitoring and operation overview can be performed over the PIS network as well as over the Process Computer Network (PCN) with PMSNT-view utility. The simulator is implemented using a stimulated Windows based Ovation platform and a SGI IRIX based Plant Model Computer (PMC) using the L-3 MAPPS simulation software platform. Two PDEH stimulated systems are installed at the Krsko Full Scope Simulator (KFSS), one for foreground and another for background simulation. Stimulated PDEH hardware is essentially identical to that installed in the plant with the exception of hardware redundancy, isolation features and interface with physical plant I/O. The Ovation control logic sheets are executed with virtual controllers hosted on a simulator specific Virtual Controller Host (VCH) Workstation. The data interface between the simulator Ovation system and the PMC is accomplished through the Ethernet

  6. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  7. Screening for colorectal cancer.

    Science.gov (United States)

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  8. Cervical cancer screening programs: technical cooperation in the Caribbean.

    Science.gov (United States)

    Barnett, D B

    1996-12-01

    This article presents the findings and recommendations of the evaluation of a project that aimed to decrease mortality from cervical cancer in the Caribbean. The Cervical Cancer Control Project was initiated in 1990 in 10 countries in the Caribbean with a total population of 850,000. The project was directed at women aged 25-69 years and sought to increase cervical screening. The production of education materials was based on a KAP survey conducted in Barbados and Grenada. Findings indicate that Pap smears were more popular among young, better educated women. Men contributed to decision making on reproductive health issues, but women would follow the advice of health professionals. The following informative materials were produced: brochures on prevention, public service announcements, and posters. A follow-up survey indicated little impact of the IEC campaign to increase screenings. Training materials were produced that aimed to assure the quality in performance of Pap smear procedures among health workers. Laboratory-based cervical cytology registries were established that were compatible with PAHO/WHO systems. Quality control in laboratories was reinforced by meetings with pathologists and by exploration of the use of semi-automated cytology screening systems. Meetings were conducted in 1996 to assess whether project goals had been met. It was recommended that cost-benefit studies be conducted in order to prove to policy makers that there was a need to invest in screening programs. It was recommended that community and women's groups be encouraged to participate in awareness creation. Recruitment of the target population should be more flexible and involve possible use of mobile clinics in the workplace and communities. Simple, accurate information needs to be communicated through all available channels, including social marketing. Clinicians need to learn to manage their time and to prioritize their work load.

  9. The ILC control system

    International Nuclear Information System (INIS)

    Carwardine, J.; Saunders, C.; Arnold, N.; Lenkszus, F.; Rehlich, K.; Simrock, S.; Banerjee, b.; Chase, B.; Gottschalk, E.; Joireman, P.; Kasley, P.; Lackey, S.; McBride, P.; Pavlicek, V.; Patrick, J.; Votava, M.; Wolbers, S.; Furukawa, K.; Michizono, S.; Larson, R.S.; Downing, R.

    2007-01-01

    Since the last ICALEPCS, a small multi-region team has developed a reference design model for a control system for the International Linear Collider as part of the ILC Global Design Effort. The scale and performance parameters of the ILC accelerator require new thinking in regards to control system design. Technical challenges include the large number of accelerator systems to be controlled, the large scale of the accelerator facility, the high degree of automation needed during accelerator operations, and control system equipment requiring 'Five Nines' availability. The R and D path for high availability touches the control system hardware, software, and overall architecture, and extends beyond traditional interfaces into the technical systems. Software considerations for HA include fault detection through exhaustive out-of-band monitoring and automatic state migration to redundant systems, while the telecom industry's emerging ATCA standard - conceived, specified, and designed for High Availability - is being evaluated for suitability for ILC front-end electronics.

  10. Control system integration

    CERN Document Server

    Shea, T J

    2008-01-01

    This lecture begins with a definition of an accelerator control system, and then reviews the control system architectures that have been deployed at the larger accelerator facilities. This discussion naturally leads to identification of the major subsystems and their interfaces. We shall explore general strategies for integrating intelligent devices and signal processing subsystems based on gate arrays and programmable DSPs. The following topics will also be covered: physical packaging; timing and synchronization; local and global communication technologies; interfacing to machine protection systems; remote debugging; configuration management and source code control; and integration of commercial software tools. Several practical realizations will be presented.

  11. Stepwise strategy to improve Cervical Cancer Screening Adherence (SCAN-CC): automated text messages, phone calls and face-to-face interviews: protocol of a population-based randomised controlled trial.

    Science.gov (United States)

    Firmino-Machado, João; Mendes, Romeu; Moreira, Amélia; Lunet, Nuno

    2017-10-05

    Screening is highly effective for cervical cancer prevention and control. Population-based screening programmes are widely implemented in high-income countries, although adherence is often low. In Portugal, just over half of the women adhere to cervical cancer screening, contributing for greater mortality rates than in other European countries. The most effective adherence raising strategies are based on patient reminders, small/mass media and face-to-face educational programmes, but sequential interventions targeting the general population have seldom been evaluated. The aim of this study is to assess the effectiveness of a stepwise approach, with increasing complexity and cost, to improve adherence to organised cervical cancer screening: step 1a-customised text message invitation; step 1b-customised automated phone call invitation; step 2-secretary phone call; step 3-family health professional phone call and face-to-face appointment. A population-based randomised controlled trial will be implemented in Portuguese urban and rural areas. Women eligible for cervical cancer screening will be randomised (1:1) to intervention and control. In the intervention group, women will be invited for screening through text messages, automated phone calls, manual phone calls and health professional appointments, to be applied sequentially to participants remaining non-adherent after each step. Control will be the standard of care (written letter). The primary outcome is the proportion of women adherent to screening after step 1 or sequences of steps from 1 to 3. The secondary outcomes are: proportion of women screened after each step (1a, 2 and 3); proportion of text messages/phone calls delivered; proportion of women previously screened in a private health institution who change to organised screening. The intervention and control groups will be compared based on intention-to-treat and per-protocol analyses. The study was approved by the Ethics Committee of the Northern Health

  12. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS (A Toroidal LHC Apparatus). The ALFA system is composed by four stations installed in the LHC tunnel 240 m away from the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronics for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  13. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS/LHC. The ALFA system is composed by two stations installed in the LHC tunnel 240 m away from each side of the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronic for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  14. Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study.

    Science.gov (United States)

    Chen, Ying-Hsien; Hung, Chi-Sheng; Huang, Ching-Chang; Hung, Yu-Chien; Hwang, Juey-Jen; Ho, Yi-Lwun

    2017-09-26

    Atrial fibrillation (AF) is a common form of arrhythmia that is associated with increased risk of stroke and mortality. Detecting AF before the first complication occurs is a recognized priority. No previous studies have examined the feasibility of undertaking AF screening using a telehealth surveillance system with an embedded cloud-computing algorithm; we address this issue in this study. The objective of this study was to evaluate the feasibility of AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm. We conducted a prospective AF screening study in a nonmetropolitan area using a single-lead electrocardiogram (ECG) recorder. All ECG measurements were reviewed on the telehealth surveillance system and interpreted by the cloud-computing algorithm and a cardiologist. The process of AF screening was evaluated with a satisfaction questionnaire. Between March 11, 2016 and August 31, 2016, 967 ECGs were recorded from 922 residents in nonmetropolitan areas. A total of 22 (2.4%, 22/922) residents with AF were identified by the physician's ECG interpretation, and only 0.2% (2/967) of ECGs contained significant artifacts. The novel cloud-computing algorithm for AF detection had a sensitivity of 95.5% (95% CI 77.2%-99.9%) and specificity of 97.7% (95% CI 96.5%-98.5%). The overall satisfaction score for the process of AF screening was 92.1%. AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm is feasible. ©Ying-Hsien Chen, Chi-Sheng Hung, Ching-Chang Huang, Yu-Chien Hung, Juey-Jen Hwang, Yi-Lwun Ho. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 26.09.2017.

  15. [Organized breast cancer screening].

    Science.gov (United States)

    Rouëssé, Jacques; Sancho-Garnier, Hélèn

    2014-02-01

    Breast screening programs are increasingly controversial, especially regarding two points: the number of breast cancer deaths they avoid, and the problem of over-diagnosis and over-treatment. The French national breast cancer screening program was extended to cover the whole country in 2004. Ten years later it is time to examine the risk/benefit ratio of this program and to discuss the need for change. Like all forms of cancer management, screening must be regularly updated, taking into account the state of the art, new evidence, and uncertainties. All screening providers should keep themselves informed of the latest findings. In the French program, women aged 50-74 with no major individual or familial risk factors for breast cancer are offered screening mammography and clinical breast examination every two years. Images considered non suspicious of malignancy by a first reader are re-examined by a second reader. The devices and procedures are subjected to quality controls. Participating radiologists (both public and private) are required to read at least 500 mammographies per year. The program's national participation rate was 52.7 % in 2012. When individual screening outside of the national program is taken into account (nearly 15 % of women), coverage appears close to the European recommendation of 65 %. Breast cancer mortality has been falling in France by 0.6 % per year for over 30 years, starting before mass screening was implemented, and by 1.5 % since 2005. This decline can be attributed in part to earlier diagnosis and better treatment, so that the specific impact of screening cannot easily be measured. Over-treatment, defined as the detection and treatment of low-malignancy tumors that would otherwise not have been detected in a person's lifetime, is a major negative effect of screening, but its frequency is not precisely known (reported to range from 1 % to 30 %). In view of these uncertainties, it would be advisable to modify the program in order to

  16. Three screening methods for cognitive dysfunction using the Mini-Mental State Examination and Korean Dementia Screening Questionnaire.

    Science.gov (United States)

    Choi, Seong Hye; Park, Moon Ho

    2016-02-01

    To screen for and determine cognitive dysfunction, cognitive tests and/or informant reports are commonly used. However, these cognitive tests and informant reports are not always available. The present study investigated three screening methods using the Mini-Mental State Examination (MMSE) as the cognitive test, and the Korean dementia screening questionnaire (KDSQ) as the informant report. Participants were recruited from the Korea Clinical Research Center for Dementia of South Korea, and included 2861 patients with Alzheimer's disease (dementia), 3519 patients with mild cognitive impairment and 1375 controls with no cognitive dysfunction. Three screening methods were tested: (i) MMSE alone (MMSE(cut-off) ); (ii) a conventional combination of MMSE and KDSQ (MMSE+KDSQ(cut-off) ); and (iii) a decision tree with MMSE and KDSQ (MMSE+KDSQ(decision tree) ). For discriminating any cognitive dysfunction from controls, MMSE+KDSQ(cut-off) had the highest area under the receiver operating characteristic curve (0.784). For discriminating dementia from controls, MMSE+KDSQ(cut-off) had the highest area under the receiver operating characteristic curve (0.899). For discriminating mild cognitive impairment from controls, MMSE(cut-off) had the highest area under the receiver operating characteristic curve (0.683). MMSE+KDSQ(decision tree) showed the highest sensitivity for all discriminations. For overall classification accuracy, MMSE+KDSQ(decision tree) had the highest value (70.0%). These three methods had different advantageous properties for screening and staging cognitive dysfunction. As there might be different availability across clinical settings, these three methods can be selected and used according to situational needs. © 2015 Japan Geriatrics Society.

  17. The Stanford Automated Mounter: Enabling High-Throughput Protein Crystal Screening at SSRL

    International Nuclear Information System (INIS)

    Smith, C.A.; Cohen, A.E.

    2009-01-01

    The macromolecular crystallography experiment lends itself perfectly to high-throughput technologies. The initial steps including the expression, purification, and crystallization of protein crystals, along with some of the later steps involving data processing and structure determination have all been automated to the point where some of the last remaining bottlenecks in the process have been crystal mounting, crystal screening, and data collection. At the Stanford Synchrotron Radiation Laboratory, a National User Facility that provides extremely brilliant X-ray photon beams for use in materials science, environmental science, and structural biology research, the incorporation of advanced robotics has enabled crystals to be screened in a true high-throughput fashion, thus dramatically accelerating the final steps. Up to 288 frozen crystals can be mounted by the beamline robot (the Stanford Auto-Mounting System) and screened for diffraction quality in a matter of hours without intervention. The best quality crystals can then be remounted for the collection of complete X-ray diffraction data sets. Furthermore, the entire screening and data collection experiment can be controlled from the experimenter's home laboratory by means of advanced software tools that enable network-based control of the highly automated beamlines.

  18. Comparison of digital selenium radiography with an analog screen-film system in the diagnostic process of pneumoconiosis according to ILO classification

    International Nuclear Information System (INIS)

    Zaehringer, M.; Winnekendonk, G.; Gossmann, A.; Krueger, K.; Krug, B.

    2001-01-01

    Purpose: The aim of the study was to determine the diagnostic value of digital selenium radiography in patients with pneumoconiosis. For this purpose chest X-rays by digital selenium radiography and analog screen-film system were compared according to the ILO classification of pneumoconiosis. Method: After approval of the study by the local ethic commission and the Federal German Office for Radiation Protection 50 patients were subjected to X-rays by digital selenium radiography (Thoravision; Philips Medical Systems, Hamburg, Germany) and analog screen-film system of the same day within the scope of an industrial medicine preventive checkup. Four investigators rated the chest X-rays according to the ILO classification of pneumoconiosis. Results: The findings demonstrated by chest X-rays according to ILO classification were rated similar by digital selenium radiography and analog screen film systems. Image quality of the digital pictures was rated significantly better. Conclusion: The use of digital selenium radiography in evaluating chest X-rays according to the ILO classification does not result in over- or underestimation of pulmonary pathologies. Hence, in the diagnosis of pneumoconiosis, digital selenium radiography can replace the tested analog screen-film system. (orig.) [de

  19. The CEBAF control system

    International Nuclear Information System (INIS)

    Watson, W.A. III.

    1995-01-01

    CEBAF has recently upgraded its accelerator control system to use EPICS, a control system toolkit being developed by a collaboration among laboratories in the US and Europe. The migration to EPICS has taken place during a year of intense commissioning activity, with new and old control systems operating concurrently. Existing CAMAC hardware was preserved by adding a CAMAC serial highway link to VME; newer hardware developments are now primarily in VME. Software is distributed among three tiers of computers: first, workstations and X terminals for operator interfaces and high level applications; second, VME single board computers for distributed access to hardware and for local control processing; third, embedded processors where needed for faster closed loop operation. This system has demonstrated the ability to scale EPICS to controlling thousands of devices, including hundreds of embedded processors, with control distributed among dozens of VME processors executing more than 125,000 EPICS database records. To deal with the large size of the control system, CEBAF has integrated an object oriented database, providing data management capabilities for both low level I/O and high level machine modeling. A new callable interface which is control system independent permits access to live EPICS data, data in other Unix processes, and data contained in the object oriented database

  20. Output controllability of nonlinear systems with bounded control

    International Nuclear Information System (INIS)

    Garcia, Rafael; D'Attellis, Carlos

    1990-01-01

    The control problem treated in this paper is the output controllability of a nonlinear system in the form: x = f(x) + g(x)u(t); y = h(x), using bounded controls. The approach to the problem consists of a modification in the system using dynamic feedback in such a way that the input/output behaviour of the closed loop matches the input/output behaviour of a completely output-controllable system with bounded controls. Sufficient conditions are also put forward on the system so that a compact set in the output space may be reached in finite time using uniformally bounded controls, and a result on output regulation in finite time with asymptotic state stabilization is obtained. (Author)