WorldWideScience

Sample records for sclerosis lesion detection

  1. Automated detection of multiple sclerosis lesions in serial brain MRI

    International Nuclear Information System (INIS)

    Llado, Xavier; Ganiler, Onur; Oliver, Arnau; Marti, Robert; Freixenet, Jordi; Valls, Laia; Vilanova, Joan C.; Ramio-Torrenta, Lluis; Rovira, Alex

    2012-01-01

    Multiple sclerosis (MS) is a serious disease typically occurring in the brain whose diagnosis and efficacy of treatment monitoring are vital. Magnetic resonance imaging (MRI) is frequently used in serial brain imaging due to the rich and detailed information provided. Time-series analysis of images is widely used for MS diagnosis and patient follow-up. However, conventional manual methods are time-consuming, subjective, and error-prone. Thus, the development of automated techniques for the detection and quantification of MS lesions is a major challenge. This paper presents an up-to-date review of the approaches which deal with the time-series analysis of brain MRI for detecting active MS lesions and quantifying lesion load change. We provide a comprehensive reference source for researchers in which several approaches to change detection and quantification of MS lesions are investigated and classified. We also analyze the results provided by the approaches, discuss open problems, and point out possible future trends. Lesion detection approaches are required for the detection of static lesions and for diagnostic purposes, while either quantification of detected lesions or change detection algorithms are needed to follow up MS patients. However, there is not yet a single approach that can emerge as a standard for the clinical practice, automatically providing an accurate MS lesion evolution quantification. Future trends will focus on combining the lesion detection in single studies with the analysis of the change detection in serial MRI. (orig.)

  2. Automated detection of multiple sclerosis lesions in serial brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Llado, Xavier; Ganiler, Onur; Oliver, Arnau; Marti, Robert; Freixenet, Jordi [University of Girona, Computer Vision and Robotics Group, Girona (Spain); Valls, Laia [Dr. Josep Trueta University Hospital, Department of Radiology, Girona (Spain); Vilanova, Joan C. [Girona Magnetic Resonance Center, Girona (Spain); Ramio-Torrenta, Lluis [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Multiple Sclerosis and Neuroimmunology Unit, Girona (Spain); Rovira, Alex [Vall d' Hebron University Hospital, Magnetic Resonance Unit, Department of Radiology, Barcelona (Spain)

    2012-08-15

    Multiple sclerosis (MS) is a serious disease typically occurring in the brain whose diagnosis and efficacy of treatment monitoring are vital. Magnetic resonance imaging (MRI) is frequently used in serial brain imaging due to the rich and detailed information provided. Time-series analysis of images is widely used for MS diagnosis and patient follow-up. However, conventional manual methods are time-consuming, subjective, and error-prone. Thus, the development of automated techniques for the detection and quantification of MS lesions is a major challenge. This paper presents an up-to-date review of the approaches which deal with the time-series analysis of brain MRI for detecting active MS lesions and quantifying lesion load change. We provide a comprehensive reference source for researchers in which several approaches to change detection and quantification of MS lesions are investigated and classified. We also analyze the results provided by the approaches, discuss open problems, and point out possible future trends. Lesion detection approaches are required for the detection of static lesions and for diagnostic purposes, while either quantification of detected lesions or change detection algorithms are needed to follow up MS patients. However, there is not yet a single approach that can emerge as a standard for the clinical practice, automatically providing an accurate MS lesion evolution quantification. Future trends will focus on combining the lesion detection in single studies with the analysis of the change detection in serial MRI. (orig.)

  3. Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

    Science.gov (United States)

    Chou, I-Jun; Lim, Su-Yin; Tanasescu, Radu; Al-Radaideh, Ali; Mougin, Olivier E; Tench, Christopher R; Whitehouse, William P; Gowland, Penny A; Constantinescu, Cris S

    2018-03-01

    Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT w ) images in the detection of white matter lesions compared with 3T-FLAIR. Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT w and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT w images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT w images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). Seven-Tesla MT w sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT w imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT w imaging. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  4. Fully automatic detection of deep white matter T1 hypointense lesions in multiple sclerosis

    Science.gov (United States)

    Spies, Lothar; Tewes, Anja; Suppa, Per; Opfer, Roland; Buchert, Ralph; Winkler, Gerhard; Raji, Alaleh

    2013-12-01

    A novel method is presented for fully automatic detection of candidate white matter (WM) T1 hypointense lesions in three-dimensional high-resolution T1-weighted magnetic resonance (MR) images. By definition, T1 hypointense lesions have similar intensity as gray matter (GM) and thus appear darker than surrounding normal WM in T1-weighted images. The novel method uses a standard classification algorithm to partition T1-weighted images into GM, WM and cerebrospinal fluid (CSF). As a consequence, T1 hypointense lesions are assigned an increased GM probability by the standard classification algorithm. The GM component image of a patient is then tested voxel-by-voxel against GM component images of a normative database of healthy individuals. Clusters (≥0.1 ml) of significantly increased GM density within a predefined mask of deep WM are defined as lesions. The performance of the algorithm was assessed on voxel level by a simulation study. A maximum dice similarity coefficient of 60% was found for a typical T1 lesion pattern with contrasts ranging from WM to cortical GM, indicating substantial agreement between ground truth and automatic detection. Retrospective application to 10 patients with multiple sclerosis demonstrated that 93 out of 96 T1 hypointense lesions were detected. On average 3.6 false positive T1 hypointense lesions per patient were found. The novel method is promising to support the detection of hypointense lesions in T1-weighted images which warrants further evaluation in larger patient samples.

  5. detecting multiple sclerosis lesions with a fully bioinspired visual attention model

    Science.gov (United States)

    Villalon-Reina, Julio; Gutierrez-Carvajal, Ricardo; Thompson, Paul M.; Romero-Castro, Eduardo

    2013-11-01

    The detection, segmentation and quantification of multiple sclerosis (MS) lesions on magnetic resonance images (MRI) has been a very active field for the last two decades because of the urge to correlate these measures with the effectiveness of pharmacological treatment. A myriad of methods has been developed and most of these are non specific for the type of lesions and segment the lesions in their acute and chronic phases together. On the other hand, radiologists are able to distinguish between several stages of the disease on different types of MRI images. The main motivation of the work presented here is to computationally emulate the visual perception of the radiologist by using modeling principles of the neuronal centers along the visual system. By using this approach we are able to detect the lesions in the majority of the images in our population sample. This type of approach also allows us to study and improve the analysis of brain networks by introducing a priori information.

  6. A comparison between fast and conventional spin-echo in the detection of multiple sclerosis lesions

    International Nuclear Information System (INIS)

    Thorpe, J.W.; Halpin, S.F.; MacManus, D.G.; Barker, G.J.; Kendall, B.E.; Miller, D.H.

    1994-01-01

    Long repetition time (TR) spin-echo (SE) with T 2 - or proton density weighting is the sequence of choice to detect the brain lesions of multiple sclerosis (MS). Fast spin-echo (FSE) permits the generation of T 2 -weighted images with similar contrast to SE but in a fraction of the time. We compared the sensitivity of FSE and SE in the detection of the brain lesions of MS. Six patients with clinically definite MS underwent brain imaging with both dual echo (long TR, long and short echo time (TE) SE and dual echo FSE. The SE and FSE images were first reviewed independently and then compared. A total of 404 lesions was detected on SE and 398 on FSE. Slightly more periventricular lesions were detected using SE than FSE (145 vs 127), whereas more posterior cranial fossa lesions were detected by FSE (77 vs 57). With both SE and FSE the short TE images revealed more lesions than the long echo. These results suggest that FSE could replace SE as the long TR sequence of choice in the investigation of MS. (orig.)

  7. A subtraction pipeline for automatic detection of new appearing multiple sclerosis lesions in longitudinal studies

    Energy Technology Data Exchange (ETDEWEB)

    Ganiler, Onur; Oliver, Arnau; Diez, Yago; Freixenet, Jordi; Llado, Xavier [University of Girona, VICOROB Computer Vision and Robotics Group, Girona (Spain); Vilanova, Joan C. [Girona Magnetic Resonance Center, Girona (Spain); Beltran, Brigitte [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Girona (Spain); Ramio-Torrenta, Lluis [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Multiple Sclerosis and Neuroimmunology Unit, Girona (Spain); Rovira, Alex [Vall d' Hebron University Hospital, Magnetic Resonance Unit, Department of Radiology, Barcelona (Spain)

    2014-05-15

    Time-series analysis of magnetic resonance images (MRI) is of great value for multiple sclerosis (MS) diagnosis and follow-up. In this paper, we present an unsupervised subtraction approach which incorporates multisequence information to deal with the detection of new MS lesions in longitudinal studies. The proposed pipeline for detecting new lesions consists of the following steps: skull stripping, bias field correction, histogram matching, registration, white matter masking, image subtraction, automated thresholding, and postprocessing. We also combine the results of PD-w and T2-w images to reduce false positive detections. Experimental tests are performed in 20 MS patients with two temporal studies separated 12 (12M) or 48 (48M) months in time. The pipeline achieves very good performance obtaining an overall sensitivity of 0.83 and 0.77 with a false discovery rate (FDR) of 0.14 and 0.18 for the 12M and 48M datasets, respectively. The most difficult situation for the pipeline is the detection of very small lesions where the obtained sensitivity is lower and the FDR higher. Our fully automated approach is robust and accurate, allowing detection of new appearing MS lesions. We believe that the pipeline can be applied to large collections of images and also be easily adapted to monitor other brain pathologies. (orig.)

  8. Comparative analysis of MR sequences to detect structural brain lesions in tuberous sclerosis

    International Nuclear Information System (INIS)

    Pinto Gama, Hugo Pereira; Campos Meirelles, Rogerio Goncalves de; Mendonca do Rego, Jose Iram; Rocha, Antonio Jose da; Silva, Carlos Jorge da; Braga, Flavio Tulio; Martins Maia, Antonio Carlos; Lederman, Henrique Manoel

    2006-01-01

    Tuberous sclerosis (TS) is a neurocutaneous genetically inherited disease with variable penetrance characterized by dysplasias and hamartomas affecting multiple organs. MR is the imaging method of choice to demonstrate structural brain lesions in TS. To compare MR sequences and determine which is most useful for the demonstration of each type of brain lesion in TS patients. We reviewed MR scans of 18 TS patients for the presence of cortical tubers, white matter lesions (radial bands), subependymal nodules, and subependymal giant cell astrocytoma (SGCA) on the following sequences: (1) T1-weighted spin-echo (T1 SE) images before and after gadolinium (Gd) injection; (2) nonenhanced T1 SE sequence with an additional magnetization transfer contrast medium pulse on resonance (T1 SE/MTC); and (3) fluid-attenuated inversion recovery (FLAIR) sequence. Cortical tubers were found in significantly (P<0.05) larger numbers and more conspicuously in FLAIR and T1 SE/MTC sequences. The T1 SE/MTC sequence was far superior to other methods in detecting white matter lesions (P<0.01). There was no significant difference between the T1 SE/MTC and T1 SE (before and after Gd injection) sequences in the detection of subependymal nodules; FLAIR sequence showed less sensitivity than the others in identifying the nodules. T1 SE sequences after Gd injection demonstrated better the limits of the SGCA. We demonstrated the importance of appropriate MRI sequences for diagnosis of the most frequent brain lesions in TS. Our study reinforces the fact that each sequence has a particular application according to the type of TS lesion. Gd injection might be useful in detecting SGCA; however, the parameters of size and location are also important for a presumptive diagnosis of these tumors. (orig.)

  9. Improved assessment of multiple sclerosis lesion segmentation agreement via detection and outline error estimates

    Directory of Open Access Journals (Sweden)

    Wack David S

    2012-07-01

    Full Text Available Abstract Background Presented is the method “Detection and Outline Error Estimates” (DOEE for assessing rater agreement in the delineation of multiple sclerosis (MS lesions. The DOEE method divides operator or rater assessment into two parts: 1 Detection Error (DE -- rater agreement in detecting the same regions to mark, and 2 Outline Error (OE -- agreement of the raters in outlining of the same lesion. Methods DE, OE and Similarity Index (SI values were calculated for two raters tested on a set of 17 fluid-attenuated inversion-recovery (FLAIR images of patients with MS. DE, OE, and SI values were tested for dependence with mean total area (MTA of the raters' Region of Interests (ROIs. Results When correlated with MTA, neither DE (ρ = .056, p=.83 nor the ratio of OE to MTA (ρ = .23, p=.37, referred to as Outline Error Rate (OER, exhibited significant correlation. In contrast, SI is found to be strongly correlated with MTA (ρ = .75, p  Conclusions The DE and OER indices are proposed as a better method than SI for comparing rater agreement of ROIs, which also provide specific information for raters to improve their agreement.

  10. Comparison between immediate and delayed imaging after gadolinium chelate injection for detecting enhanced lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Alizadeh, A.; Roudbari, A.; Heidarzadeh, A.; Kouhsari, M.

    2010-01-01

    Magnetic resonance imaging is a noninvasive and valuable method in the diagnosis of Multiple Sclerosis. Compared with other modalities, the sensitivity of Magnetic resonance imaging for detection of the lesion increases using magnetization transfer and delayed imaging. Our aim was to compare the two methods in detecting Multiple Sclerosis lesions. Patients and Methods: In this double-blind clinical trial, twenty-one patients with the definite diagnosis of Multiple Sclerosis referred to Poursina Hospital, Rasht were included. Two radiologists evaluated all the images. First, images without contrast were conducted, then 0.1 mmol/kg contrast material (Dotarem, single dose) was injected and after 30 minutes, T1W and magnetization transfer images were obtained. Seventy-two hours later, T1W images were obtained immediately after injection of 0.2 mmol/kg contrast material (double dose). The data were analyzed using Fisher's and McNemar tests by SPSS for Windows. Results: Delayed magnetization transfer showed 44 enhanced lesions using magnetization transfer (69.84%) and 29 lesions using T1 (46.03%). In addition, the number of enhanced lesions in the delayed method were significantly more than those in the immediate method (p value=0.003). Conclusion: The use of single dose in combination with magnetization transfer and delayed images after 20-30 minutes enables us to detect more enhanced lesions.

  11. MRI detection of hypointense brain lesions in patients with multiple sclerosis: T1 spin-echo vs. gradient-echo

    Energy Technology Data Exchange (ETDEWEB)

    Dupuy, Sheena L.; Tauhid, Shahamat; Kim, Gloria; Chu, Renxin; Tummala, Subhash [Departments of Neurology, Brigham and Women' s Hospital, Laboratory for Neuroimaging Research, Partners MS Center, Harvard Medical School, Boston, MA (United States); Hurwitz, Shelley [Departments of Medicine, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States); Bakshi, Rohit, E-mail: rbakshi@bwh.harvard.edu [Departments of Neurology, Brigham and Women' s Hospital, Laboratory for Neuroimaging Research, Partners MS Center, Harvard Medical School, Boston, MA (United States); Departments of Radiology, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States)

    2015-08-15

    Highlights: • Compared T1SE and T1GE in detecting hypointense brain lesions in MS patients. • T1GE detected a higher cerebral lesion volume and number than T1SE. • T1SE correlated significantly with disability, while T1GE did not. • Hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. - Abstract: Objective: Compare T1 spin-echo (T1SE) and T1 gradient-echo (T1GE) sequences in detecting hypointense brain lesions in multiple sclerosis (MS). Background: Chronic hypointense lesions on T1SE MRI scans are a surrogate of severe demyelination and axonal loss in MS. The role of T1GE images in the detection of such lesions has not been clarified. Design/methods: In 45 patients with MS [Expanded Disability Status Scale (EDSS) score (mean ± SD) 3.5 ± 2.0; 37 relapsing-remitting (RR); 8 secondary progressive (SP)], cerebral T1SE, T1GE, and T2-weighted fluid-attenuated inversion-recovery (FLAIR) images were acquired on a 1.5 T MRI scanner. Images were re-sampled to axial 5 mm slices before directly comparing lesion detectability using Jim (v.7, Xinapse Systems). Statistical methods included Wilcoxon signed rank tests to compare sequences and Spearman correlations to test associations. Results: Considering the entire cohort, T1GE detected a higher lesion volume (5.90 ± 6.21 vs. 4.17 ± 4.84 ml, p < 0.0001) and higher lesion number (27.82 ± 20.66 vs. 25.20 ± 20.43, p < 0.05) than T1SE. Lesion volume differences persisted when considering RR and SP patients separately (both p < 0.01). A higher lesion number by T1GE was seen only in the RR group (p < 0.05). When comparing correlations between lesion volume and overall neurologic disability (EDSS score), T1SE correlated with EDSS (Spearman r = 0.29, p < 0.05) while T1GE (r = 0.23, p = 0.13) and FLAIR (r = 0.24, p = 0.12) did not. Conclusion: Our data suggest that hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. Based on these results, we hypothesize that T1GE

  12. MRI detection of hypointense brain lesions in patients with multiple sclerosis: T1 spin-echo vs. gradient-echo

    International Nuclear Information System (INIS)

    Dupuy, Sheena L.; Tauhid, Shahamat; Kim, Gloria; Chu, Renxin; Tummala, Subhash; Hurwitz, Shelley; Bakshi, Rohit

    2015-01-01

    Highlights: • Compared T1SE and T1GE in detecting hypointense brain lesions in MS patients. • T1GE detected a higher cerebral lesion volume and number than T1SE. • T1SE correlated significantly with disability, while T1GE did not. • Hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. - Abstract: Objective: Compare T1 spin-echo (T1SE) and T1 gradient-echo (T1GE) sequences in detecting hypointense brain lesions in multiple sclerosis (MS). Background: Chronic hypointense lesions on T1SE MRI scans are a surrogate of severe demyelination and axonal loss in MS. The role of T1GE images in the detection of such lesions has not been clarified. Design/methods: In 45 patients with MS [Expanded Disability Status Scale (EDSS) score (mean ± SD) 3.5 ± 2.0; 37 relapsing-remitting (RR); 8 secondary progressive (SP)], cerebral T1SE, T1GE, and T2-weighted fluid-attenuated inversion-recovery (FLAIR) images were acquired on a 1.5 T MRI scanner. Images were re-sampled to axial 5 mm slices before directly comparing lesion detectability using Jim (v.7, Xinapse Systems). Statistical methods included Wilcoxon signed rank tests to compare sequences and Spearman correlations to test associations. Results: Considering the entire cohort, T1GE detected a higher lesion volume (5.90 ± 6.21 vs. 4.17 ± 4.84 ml, p < 0.0001) and higher lesion number (27.82 ± 20.66 vs. 25.20 ± 20.43, p < 0.05) than T1SE. Lesion volume differences persisted when considering RR and SP patients separately (both p < 0.01). A higher lesion number by T1GE was seen only in the RR group (p < 0.05). When comparing correlations between lesion volume and overall neurologic disability (EDSS score), T1SE correlated with EDSS (Spearman r = 0.29, p < 0.05) while T1GE (r = 0.23, p = 0.13) and FLAIR (r = 0.24, p = 0.12) did not. Conclusion: Our data suggest that hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. Based on these results, we hypothesize that T1GE

  13. Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results

    International Nuclear Information System (INIS)

    Bink, Andrea; Gaa, Jochen; Lanfermann, Heinrich; Zanella, Friedhelm E.; Schmitt, Melanie; Mugler, John P.

    2006-01-01

    The aim of this study was to compare conventional 2D FLAIR and single-slab 3D FLAIR sequences in the detection of lesions in patients with multiple sclerosis. Eight patients with MS were examined at 3.0 T by using a 2D FLAIR sequence and a single-slab 3D FLAIR sequence. A comparison of lesion detectability was performed for the following regions: periventricular, nonperiventricular/juxtacortical and infratentorial. The contrast-to-noise ratios (CNRs) between lesions and brain tissue and CSF were calculated for each sequence. A total of 424 lesions were found using the 2D FLAIR sequence, while with the 3D FLAIR sequence 719 lesions were found. With the 2D FLAIR sequence, 41% fewer lesions were detected than with the 3D FLAIR sequence. Further, 40% fewer supratentorial and 62.5% fewer infratentorial lesions were found with the 2D FLAIR sequence. In images acquired with the 3D FLAIR sequence, the lesions had significantly higher CNRs than in images acquired with the 2D FLAIR sequence. These are the first results using a single-slab 3D FLAIR sequence at 3.0 T for detection of lesions in patients with MS. With the 3D FLAIR sequence significantly higher CNRs were achieved and significantly more lesions in patients with MS were detected. (orig.)

  14. Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with primary progressive multiple sclerosis.

    Science.gov (United States)

    Filippi, M; Campi, A; Martinelli, V; Colombo, B; Yousry, T; Canal, N; Scotti, G; Comi, G

    1995-01-01

    This study was performed to evaluate whether a triple dose of gadolinium-DTPA (Gd-DTPA) increases the sensitivity of brain MRI for detecting enhancing lesions in patients with primary progressive multiple sclerosis (PPMS). T1 weighted brain MRI was obtained for 10 patients with PPMS in two sessions. In the first session, one scan was obtained five to seven minutes after the injection of 0.1 mmol/kg Gd-DTPA (standard dose). In the second session, six to 24 hours later, one scan before and two scans five to seven minutes and one hour after the injection of 0.3 mmol/kg Gd-DTPA (triple dose) were obtained. Four enhancing lesions were detected in two patients when the standard dose of Gd-DTPA was used. The numbers of enhancing lesions increased to 13 and the numbers of patients with such lesions to five when the triple dose of Gd-DTPA was used and to 14 and six in the one hour delayed scans. The mean contrast ratio for enhancing lesions detected with the triple dose of Gd-DTPA was higher than those for lesions present in both the standard dose (P DTPA many more enhancing lesions can be detected in patients with PPMS. This is important both for planning clinical trials and for detecting the presence of inflammation in vivo in the lesions of such patients. Images PMID:8530944

  15. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  16. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  17. Comparison of a conventional cardiac-triggered dual spin-echo and a fast STIR sequence in detection of spinal cord lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Bot, J.C.J.; Barkhof, F.; Lycklama a Nijeholt, G.J.; Bergers, E.; Castelijns, J.A.; Polman, C.H.; Ader, H.J.

    2000-01-01

    The current optimal imaging protocol in spinal cord MR imaging in patients with multiple sclerosis includes a long TR conventional spin-echo (CSE) sequence, requiring long acquisition times. Using short tau inversion recovery fast spin-echo (fast STIR) sequences both acquisition time can be shortened and sensitivity in the detection of multiple sclerosis (MS) abnormalities can be increased. This study compares both sequences for the potential to detect both focal and diffuse spinal abnormalities. Spinal cords of 5 volunteers and 20 MS patients were studied at 1.0 T. Magnetic resonance imaging included cardiac-gated sagittal dual-echo CSE and a cardiac-gated fast STIR sequence. Images were scored regarding number, size, and location of focal lesions, diffuse abnormalities and presence/hindrance of artifacts by two experienced radiologists. Examinations were scored as being definitely normal, indeterminate, or definitely abnormal. Interobserver agreement regarding focal lesions was higher for CSE (κ=0.67) than for fast STIR (κ=0.57) but did not differ significantly. Of all focal lesions scored in consensus, 47 % were scored on both sequences, 31 % were only detected by fast STIR, and 22 % only by dual-echo CSE (n. s.). Interobserver agreement for diffuse abnormalities was lower with fast STIR (κ=0.48) than dual-echo CSE (κ=0.65; n. s.). After consensus, fast STIR showed in 10 patients diffuse abnormalities and dual-echo CSE in 3. After consensus, in 19 of 20 patients dual-echo CSE scans were considered as definitely abnormal compared with 17 for fast STIR. The fast STIR sequence is a useful adjunct to dual-echo CSE in detecting focal abnormalities and is helpful in detecting diffuse MS abnormalities in the spinal cord. Due to the frequent occurrence of artifacts and the lower observer concordance, fast STIR cannot be used alone. (orig.)

  18. Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period.

    Directory of Open Access Journals (Sweden)

    Tobias Djamsched Faizy

    Full Text Available In patients with multiple sclerosis (MS, Double Inversion Recovery (DIR magnetic resonance imaging (MRI can be used to identify cortical lesions (CL. We sought to evaluate the reliability of CL detection on DIR longitudinally at multiple subsequent time-points applying the MAGNIMs scoring criteria for CLs.26 MS patients received a 3T-MRI (Siemens, Skyra with DIR at 12 time-points (TP within a 16 months period. Scans were assessed in random order by two different raters. Both raters separately marked all CLs on each scan and total lesion numbers were obtained for each scan-TP and patient. After a retrospective re-evaluation, the number of consensus CLs (conL was defined as the total number of CLs, which both raters finally agreed on. CLs volumes, relative signal intensities and CLs localizations were determined. Both ratings (conL vs. non-consensus scoring were compared for further analysis.A total number of n = 334 CLs were identified by both raters in 26 MS patients with a first agreement of both raters on 160 out of 334 of the CLs found (κ = 0.48. After the retrospective re-evaluation, consensus agreement increased to 233 out of 334 CL (κ = 0.69. 93.8% of conL were visible in at least 2 consecutive TP. 74.7% of the conL were visible in all 12 consecutive TP. ConL had greater mean lesion volumes and higher mean signal intensities compared to lesions that were only detected by one of the raters (p<0.05. A higher number of CLs in the frontal, parietal, temporal and occipital lobe were identified by both raters than the number of those only identified by one of the raters (p<0.05.After a first assessment, slightly less than a half of the CL were considered as reliably detectable on longitudinal DIR images. A retrospective re-evaluation notably increased the consensus agreement. However, this finding is narrowed, considering the fact that retrospective evaluation steps might not be practicable in clinical routine. Lesions that were not reliably

  19. A flexible mixed-effect negative binomial regression model for detecting unusual increases in MRI lesion counts in individual multiple sclerosis patients.

    Science.gov (United States)

    Kondo, Yumi; Zhao, Yinshan; Petkau, John

    2015-06-15

    We develop a new modeling approach to enhance a recently proposed method to detect increases of contrast-enhancing lesions (CELs) on repeated magnetic resonance imaging, which have been used as an indicator for potential adverse events in multiple sclerosis clinical trials. The method signals patients with unusual increases in CEL activity by estimating the probability of observing CEL counts as large as those observed on a patient's recent scans conditional on the patient's CEL counts on previous scans. This conditional probability index (CPI), computed based on a mixed-effect negative binomial regression model, can vary substantially depending on the choice of distribution for the patient-specific random effects. Therefore, we relax this parametric assumption to model the random effects with an infinite mixture of beta distributions, using the Dirichlet process, which effectively allows any form of distribution. To our knowledge, no previous literature considers a mixed-effect regression for longitudinal count variables where the random effect is modeled with a Dirichlet process mixture. As our inference is in the Bayesian framework, we adopt a meta-analytic approach to develop an informative prior based on previous clinical trials. This is particularly helpful at the early stages of trials when less data are available. Our enhanced method is illustrated with CEL data from 10 previous multiple sclerosis clinical trials. Our simulation study shows that our procedure estimates the CPI more accurately than parametric alternatives when the patient-specific random effect distribution is misspecified and that an informative prior improves the accuracy of the CPI estimates. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aymerich, F.X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Universitat Politecnica de Catalunya - Barcelona Tech (UPC), Department of Automatic Control (ESAII), Barcelona (Spain); Auger, C.; Alcaide-Leon, P.; Pareto, D.; Huerga, E.; Corral, J.F.; Mitjana, R.; Rovira, A. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Sastre-Garriga, J.; Montalban, X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Centre d' Esclerosi Multiple de Catalunya (Cemcat), Department of Neurology/Neuroimmunology, Barcelona (Spain)

    2017-04-15

    To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 2D T1-weighted gradient-echo (GRE) and spin-echo (SE) sequences, and to assess the influence of visual conspicuity and laterality on detection of these lesions. One hundred MS patients underwent 3.0T brain MRI including gadolinium-enhanced 2D T1-weighted GRE and SE sequences. The two sets of contrast-enhanced scans were evaluated in random fashion by three experienced readers. Lesion conspicuity was assessed by the image contrast ratio (CR) and contrast-to-noise ratio (CNR). The intracranial region was divided into four quadrants and the impact of lesion location on detection was assessed in each slice. Six hundred and seven gadolinium-enhancing MS lesions were identified. GRE images were more sensitive for lesion detection (0.828) than SE images (0.767). Lesions showed a higher CR in SE than in GRE images, whereas the CNR was higher in GRE than SE. Most misclassifications occurred in the right posterior quadrant. The gadolinium-enhanced 2D T1-weighted GRE sequence at 3.0T MRI enables detection of enhancing MS lesions with higher sensitivity and better lesion conspicuity than 2D T1-weighted SE. Hence, we propose the use of gadolinium-enhanced GRE sequences rather than SE sequences for routine scanning of MS patients at 3.0T. (orig.)

  1. A toolbox for multiple sclerosis lesion segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Roura, Eloy; Oliver, Arnau; Valverde, Sergi; Llado, Xavier [University of Girona, Computer Vision and Robotics Group, Girona (Spain); Cabezas, Mariano; Pareto, Deborah; Rovira, Alex [Vall d' Hebron University Hospital, Magnetic Resonance Unit, Dept. of Radiology, Barcelona (Spain); Vilanova, Joan C. [Girona Magnetic Resonance Center, Girona (Spain); Ramio-Torrenta, Lluis [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Multiple Sclerosis and Neuroimmunology Unit, Girona (Spain)

    2015-10-15

    Lesion segmentation plays an important role in the diagnosis and follow-up of multiple sclerosis (MS). This task is very time-consuming and subject to intra- and inter-rater variability. In this paper, we present a new tool for automated MS lesion segmentation using T1w and fluid-attenuated inversion recovery (FLAIR) images. Our approach is based on two main steps, initial brain tissue segmentation according to the gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) performed in T1w images, followed by a second step where the lesions are segmented as outliers to the normal apparent GM brain tissue on the FLAIR image. The tool has been validated using data from more than 100 MS patients acquired with different scanners and at different magnetic field strengths. Quantitative evaluation provided a better performance in terms of precision while maintaining similar results on sensitivity and Dice similarity measures compared with those of other approaches. Our tool is implemented as a publicly available SPM8/12 extension that can be used by both the medical and research communities. (orig.)

  2. A toolbox for multiple sclerosis lesion segmentation

    International Nuclear Information System (INIS)

    Roura, Eloy; Oliver, Arnau; Valverde, Sergi; Llado, Xavier; Cabezas, Mariano; Pareto, Deborah; Rovira, Alex; Vilanova, Joan C.; Ramio-Torrenta, Lluis

    2015-01-01

    Lesion segmentation plays an important role in the diagnosis and follow-up of multiple sclerosis (MS). This task is very time-consuming and subject to intra- and inter-rater variability. In this paper, we present a new tool for automated MS lesion segmentation using T1w and fluid-attenuated inversion recovery (FLAIR) images. Our approach is based on two main steps, initial brain tissue segmentation according to the gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) performed in T1w images, followed by a second step where the lesions are segmented as outliers to the normal apparent GM brain tissue on the FLAIR image. The tool has been validated using data from more than 100 MS patients acquired with different scanners and at different magnetic field strengths. Quantitative evaluation provided a better performance in terms of precision while maintaining similar results on sensitivity and Dice similarity measures compared with those of other approaches. Our tool is implemented as a publicly available SPM8/12 extension that can be used by both the medical and research communities. (orig.)

  3. Quantification of diagnostic biomarkers to detect multiple sclerosis lesions employing 1H-MRSI at 3T

    International Nuclear Information System (INIS)

    Vafaeyan, H.; Ebrahimzadeh, S.A.; Rahimian, N.; Harirchian, M.H.; Alavijeh, S. Karimi; Rad, H. Saligheh; Madadi, A.; Faeghi, F.

    2015-01-01

    Proton magnetic resonance spectroscopic imaging ( 1 H-MRSI) enables the quantification of metabolite concentration ratios in the brain. The major purpose of the current work is to characterize NAA/Cho, NAA/Cr and Myo/Cr in multiple sclerosis (MS) patients, and to estimate their reproducibility in healthy controls. Twelve MS patients and five healthy volunteers were imaged using 1 H-MRSI at 3T. Eddy current correction was performed using a single-voxel non-water suppressed acquisition on an external water phantom. Time-domain quantification was carried out using subtract-QUEST technique, and based on an optimal simulated metabolite database. Reproducibility was evaluated on the same quantified ratios in five normal subjects. An optimal database was created for the quantification of the MRSI data, consisting of choline (Cho), creatine (Cr), N-acetyl aspartate (NAA), lactate (Lac), lipids, myo-inositol (Myo) and glutamine + glutamate (Glx). Decreasing of NAA/Cr and NAA/Cho ratios, as well as an increase in Myo/Cr ratio were observed for MS patients in comparison with control group. Reproducibility of NAA/Cr, NAA/Cho and Myo/Cr in control group was 0.98, 0.87 and 0.64, respectively, expressed as the squared correlation coefficient R 2 between duplicate experiments. We showed that MRSI alongside the time-domain quantification of spectral ratios offers a sensitive and reproducible framework to differentiate MS patients from normals.

  4. Segmentation of multiple sclerosis lesions in MR images: a review

    Energy Technology Data Exchange (ETDEWEB)

    Mortazavi, Daryoush; Kouzani, Abbas Z. [Deakin University, School of Engineering, Geelong, Victoria (Australia); Soltanian-Zadeh, Hamid [Henry Ford Health System, Image Analysis Laboratory, Radiology Department, Detroit, MI (United States); University of Tehran, Control and Intelligent Processing Center of Excellence (CIPCE), School of Electrical and Computer Engineering, Tehran (Iran, Islamic Republic of); School of Cognitive Sciences, Institute for Studies in Theoretical Physics and Mathematics (IPM), Tehran (Iran, Islamic Republic of)

    2012-04-15

    Multiple sclerosis (MS) is an inflammatory demyelinating disease that the parts of the nervous system through the lesions generated in the white matter of the brain. It brings about disabilities in different organs of the body such as eyes and muscles. Early detection of MS and estimation of its progression are critical for optimal treatment of the disease. For diagnosis and treatment evaluation of MS lesions, they may be detected and segmented in Magnetic Resonance Imaging (MRI) scans of the brain. However, due to the large amount of MRI data to be analyzed, manual segmentation of the lesions by clinical experts translates into a very cumbersome and time consuming task. In addition, manual segmentation is subjective and prone to human errors. Several groups have developed computerized methods to detect and segment MS lesions. These methods are not categorized and compared in the past. This paper reviews and compares various MS lesion segmentation methods proposed in recent years. It covers conventional methods like multilevel thresholding and region growing, as well as more recent Bayesian methods that require parameter estimation algorithms. It also covers parameter estimation methods like expectation maximization and adaptive mixture model which are among unsupervised techniques as well as kNN and Parzen window methods that are among supervised techniques. Integration of knowledge-based methods such as atlas-based approaches with Bayesian methods increases segmentation accuracy. In addition, employing intelligent classifiers like Fuzzy C-Means, Fuzzy Inference Systems, and Artificial Neural Networks reduces misclassified voxels. (orig.)

  5. Segmentation of multiple sclerosis lesions in MR images: a review

    International Nuclear Information System (INIS)

    Mortazavi, Daryoush; Kouzani, Abbas Z.; Soltanian-Zadeh, Hamid

    2012-01-01

    Multiple sclerosis (MS) is an inflammatory demyelinating disease that the parts of the nervous system through the lesions generated in the white matter of the brain. It brings about disabilities in different organs of the body such as eyes and muscles. Early detection of MS and estimation of its progression are critical for optimal treatment of the disease. For diagnosis and treatment evaluation of MS lesions, they may be detected and segmented in Magnetic Resonance Imaging (MRI) scans of the brain. However, due to the large amount of MRI data to be analyzed, manual segmentation of the lesions by clinical experts translates into a very cumbersome and time consuming task. In addition, manual segmentation is subjective and prone to human errors. Several groups have developed computerized methods to detect and segment MS lesions. These methods are not categorized and compared in the past. This paper reviews and compares various MS lesion segmentation methods proposed in recent years. It covers conventional methods like multilevel thresholding and region growing, as well as more recent Bayesian methods that require parameter estimation algorithms. It also covers parameter estimation methods like expectation maximization and adaptive mixture model which are among unsupervised techniques as well as kNN and Parzen window methods that are among supervised techniques. Integration of knowledge-based methods such as atlas-based approaches with Bayesian methods increases segmentation accuracy. In addition, employing intelligent classifiers like Fuzzy C-Means, Fuzzy Inference Systems, and Artificial Neural Networks reduces misclassified voxels. (orig.)

  6. Sclerotic bone lesions at abdominal magnetic resonance imaging in children with tuberous sclerosis complex

    International Nuclear Information System (INIS)

    Boronat, Susana; Barber, Ignasi; Pargaonkar, Vivek; Chang, Joshua; Thiele, Elizabeth A.

    2016-01-01

    Sclerotic bone lesions are often seen on chest CT in adults with tuberous sclerosis complex. To characterize bone lesions at abdominal MRI in children with tuberous sclerosis complex. This retrospective review included 70 children with tuberous sclerosis complex who had undergone abdominal MRI for renal imaging. An additional longitudinal study was performed in 50 children who had had two or more MRI scans. Abdominal CT (eight children) and radiographs (three children) were reviewed and compared with MRI. A total of 173 sclerotic bone lesions were detected in 51/70 children (73%; 95% confidence interval: 0.61-0.82) chiefly affecting vertebral pedicles. New lesions appeared in 20 children and growth of previous sclerotic bone lesions was documented in 14 children. Sclerotic bone lesions were more frequent in girls and in children with more extensive renal involvement. Sclerotic bone lesions are commonly detected by abdominal MRI in children with tuberous sclerosis complex. They usually affect posterior vertebral elements and their number and size increase with age. As current recommendations for tuberous sclerosis complex surveillance include renal MR performed in childhood, recognition of these lesions is useful. (orig.)

  7. Sclerotic bone lesions at abdominal magnetic resonance imaging in children with tuberous sclerosis complex

    Energy Technology Data Exchange (ETDEWEB)

    Boronat, Susana [Massachusetts General Hospital, Department of Neurology, Boston, MA (United States); Universitat Autonoma de Barcelona, Department of Pediatric Neurology, Vall d' Hebron Hospital, Barcelona (Spain); Barber, Ignasi [Universitat Autonoma de Barcelona, Department of Pediatric Radiology, Vall d' Hebron Hospital, Barcelona (Spain); Pargaonkar, Vivek [Massachusetts General Hospital, Department of Radiology, Boston, MA (United States); Chang, Joshua; Thiele, Elizabeth A. [Massachusetts General Hospital, Department of Neurology, Boston, MA (United States)

    2016-05-15

    Sclerotic bone lesions are often seen on chest CT in adults with tuberous sclerosis complex. To characterize bone lesions at abdominal MRI in children with tuberous sclerosis complex. This retrospective review included 70 children with tuberous sclerosis complex who had undergone abdominal MRI for renal imaging. An additional longitudinal study was performed in 50 children who had had two or more MRI scans. Abdominal CT (eight children) and radiographs (three children) were reviewed and compared with MRI. A total of 173 sclerotic bone lesions were detected in 51/70 children (73%; 95% confidence interval: 0.61-0.82) chiefly affecting vertebral pedicles. New lesions appeared in 20 children and growth of previous sclerotic bone lesions was documented in 14 children. Sclerotic bone lesions were more frequent in girls and in children with more extensive renal involvement. Sclerotic bone lesions are commonly detected by abdominal MRI in children with tuberous sclerosis complex. They usually affect posterior vertebral elements and their number and size increase with age. As current recommendations for tuberous sclerosis complex surveillance include renal MR performed in childhood, recognition of these lesions is useful. (orig.)

  8. Magnetic resonance imaging of spinal cord lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Yagishita, Toshiyuki; Fukutake, Toshio; Hirayama, Keizo; Fukuda, Nobuo.

    1987-01-01

    Magnetic resonance imaging (MRI) was used in three patients with multiple sclerosis (MS) to demonstrate the longitudinal distribution of demyelinating plaques in the spinal cord and to measure their T1 relaxation time values in these disease processes. Neurological examination allowed the detection of the superior limit of the spinal cord lesions in the three patients, but did not permit detection of the inferior limit in two of the patients. With MRI, however, it was possible to demonstrate the longitudinal distribution of demyelinating plaques in all three patients from coronal or sagittal images using spin echo and inversion recovery pulse sequences. In two patients treated with prednisolone, serial T1 relaxation time values of MS spinal cord lesions were measured from T1 calculated images. In one patient with transverse myelopathy, the T1 relaxation time values of MS spinal cord lesions were significantly increased at a stage of acute exacerbation. This is apparently in contrast with the values at the stage of remission. In the patient with localized cervical myelopathy, the increase in T1 relaxation time values of MS spinal cord lesions at the acute stage was small and significantly different from the values at the remission stage. Several recent reports have indicated that MRI is extremely sensitive in the detection of MS plaques, but most efforts to use MRI in the diagnosis of MS have been concentrated on brain lesions in spite of their frequent associations with spinal cord involvements. It is concluded from our case studies that MRI coronal or sagittal image is useful in demonstrating the longitudinal distribution of MS spinal cord lesions. In addition, serial observations of T1 relaxation time values of MS plaques may be important in assessing the activity of MS plaques and evaluation of the steroid therapy in MS processes. (author)

  9. Stance disturbance in multiple sclerosis: brainstem lesions and posturographic assessment

    Directory of Open Access Journals (Sweden)

    Peter Schalek

    2012-01-01

    Full Text Available

    Background. Balance disorders are commonly evidenced during the course of multiple sclerosis (MS. The aim of this study is to report characteristics of MS patient stance control disorders, measured by means of posturography and related to the brainstem lesions.

    Methods. Thirty-eight patients affected by MS, mildly to moderately disable according to Kurtzke’s Expanded Disability Status Scale, underwent a complete clinical neurological and vestibular evaluation and brain MRI scanning. All patients were then tested on a static posturography platform (Tetrax, Israel in four conditions: eyes open and closed standing on a firm surface and on a foam pad.

    Results. Clinical and/or MRI evidence of brainstem involvement was observed in 55.3 % of patients. When brainstem lesion was detected, Fourier analysis showed a typical pattern characterized by inversion of the  0- 0.1 Hz and  0.1 - 0.25 Hz. frequency bands.

    Conclusions. MS leads to pervasive postural disturbances in the majority of subjects, including the visuo-vestibular loops and proprioception involving vestibulo-spinal pathways in at least 55.3 % of patients. Our results may also suggest the presence of Fourier inversion in patients with brainstem lesions.


  10. Brain atrophy and lesion load predict long term disability in multiple sclerosis

    DEFF Research Database (Denmark)

    Popescu, Veronica; Agosta, Federica; Hulst, Hanneke E

    2013-01-01

    To determine whether brain atrophy and lesion volumes predict subsequent 10 year clinical evolution in multiple sclerosis (MS).......To determine whether brain atrophy and lesion volumes predict subsequent 10 year clinical evolution in multiple sclerosis (MS)....

  11. Magnetic resonance imaging in optic nerve lesions with multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo; Kakisu, Yonetsugu; Adachi, Emiko

    1990-01-01

    Magnetic resonance imaging (MRI) of the optic nerve was performed in 10 patients with multiple sclerosis (MS) using short inversion time inversion recovery (STIR) pulse sequences, and the results were compared with the visual evoked potentials (VEP). The 10 patients had optic neuritis in the chronic or remitting phase together with additional symptoms or signs allowing a diagnosis of clinically definite or probable MS. Sixteen optic nerves were clinically affected and 4 were unaffected. MRI was performed using a 0.5 tesla supeconducting unit, and multiple continuous 5 mm coronal and axial STIR images were obtained. A lesion was judged to be present if a focal or diffuse area of increased signal intensity was detectd in the optic nerve. In VEP, a delay in peak latency or no P 100 component was judged to be abnormal. With regard to the clinically affected optic nerves, MRI revealed a region of increased signal intensity in 14/16 (88%) and the VEP was abnormal in 16/16 (100%). In the clinically unaffected optic nerves, MRI revealed an increased signal intensity in 2/4 (50%). One of these nerves had an abnormal VEP and the other had a VEP latency at the upper limit of normal. The VEP was abnormal in 1/4 (25%). In the clinically affected optic nerves, the degree of loss of visual acuity was not associated with the longitudinal extent of the lesions shown by MRI. The mean length was 17.5 mm in optic nerves with a slight disturbance of visual acuity and 15.0 mm in nerves with severe visual loss. MRI using STIR pulse sequences was found to be almost as sensitive as VEP in detecting both clinically affected and unaffected optic nerve lesions in patients with MS, and was useful in visualizing the location or size of the lesions. (author)

  12. Juxtacortical Lesions and Cortical Thinning in Multiple Sclerosis.

    Science.gov (United States)

    Pareto, D; Sastre-Garriga, J; Auger, C; Vives-Gilabert, Y; Delgado, J; Tintoré, M; Montalban, X; Rovira, A

    2015-12-01

    The role of juxtacortical lesions in brain volume loss in multiple sclerosis has not been fully clarified. The aim of this study was to explore the role of juxtacortical lesions on cortical atrophy and to investigate whether the presence of juxtacortical lesions is related to local cortical thinning in the early stages of MS. A total of 131 patients with clinically isolated syndrome or with relapsing-remitting MS were scanned on a 3T system. Patients with clinically isolated syndrome were classified into 3 groups based on the presence and topography of brain lesions: no lesions (n = 24), only non-juxtacortical lesions (n = 33), and juxtacortical lesions and non-juxtacortical lesions (n = 34). Patients with relapsing-remitting MS were classified into 2 groups: only non-juxtacortical lesions (n = 10) and with non-juxtacortical lesions and juxtacortical lesions (n = 30). A juxtacortical lesion probability map was generated, and cortical thickness was measured by using FreeSurfer. Juxtacortical lesion volume in relapsing-remitting MS was double that of patients with clinically isolated syndrome. The insula showed the highest density of juxtacortical lesions, followed by the temporal, parietal, frontal, and occipital lobes. Patients with relapsing-remitting MS with juxtacortical lesions showed significantly thinner cortices overall and in the parietal and temporal lobes compared with those with clinically isolated syndrome with normal brain MR imaging. The volume of subcortical structures (thalamus, pallidum, putamen, and accumbens) was significantly decreased in relapsing-remitting MS with juxtacortical lesions compared with clinically isolated syndrome with normal brain MR imaging. The spatial distribution of juxtacortical lesions was not found to overlap with areas of cortical thinning. Cortical thinning and subcortical gray matter volume loss in patients with a clinically isolated syndrome or relapsing-remitting MS was related to the presence of juxtacortical

  13. Systemic sclerosis complicated with localized scleroderma-like lesions induced by Köbner phenomenon.

    Science.gov (United States)

    Saigusa, Ryosuke; Asano, Yoshihide; Yamashita, Takashi; Takahashi, Takehiro; Nakamura, Kouki; Miura, Shunsuke; Ichimura, Yohei; Toyama, Tetsuo; Taniguchi, Takashi; Sumida, Hayakazu; Tamaki, Zenshiro; Miyazaki, Miki; Yoshizaki, Ayumi; Sato, Shinichi

    2018-03-01

    Scleroderma is a chronic disease of unknown etiology characterized by skin fibrosis and is divided into two clinical entities: systemic sclerosis (SSc) and localized scleroderma (LSc). In general, LSc is rarely complicated with SSc, but a certain portion of SSc patients manifests bilateral symmetric LSc-like lesions on the trunk and extremities. We investigated SSc patients with LSc-like lesions to clarify the underlying pathophysiology. Nine SSc cases complicated with LSc-like lesions were clinically and histologically characterized. SSc patients with LSc-like lesions exhibited multiple progressive hyper- and/or hypo-pigmented plaques with mild sclerosis symmetrically distributed on the trunk and extremities, especially abdominal region. In histological assessment, epidermal IL-1α expression was elevated in both forearms and LSc-like lesions of these patients to a greater extent than in forearms of control patients (SSc patients without LSc-like lesions). Of note, the infiltration and degranulation of mast cells were evident throughout the dermis of LSc-like lesions, while detectable to a lesser extent in forearms of SSc patients with LSc-like lesions and control patients. The epidermis of SSc patients with LSc-like lesions seems to possess an inflammatory phenotype, leading to the activation of mast cells in the dermis of mechanically stressed skin. Köbner phenomenon may be involved in the induction of LSc-like lesions in a certain subset of SSc. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  14. Magnetic resonance imaging of spinal cord lesions in 22 multiple sclerosis patients

    International Nuclear Information System (INIS)

    Kato, Hiroshi; Funakawa, Itaru; Hara, Kenji; Yasuda, Takeshi; Terao, Akira

    1994-01-01

    We reviewed MRI findings in 22 patients (37 cases) with clinically diagnosed multiple sclerosis (MS) with spinal cord lesions. The spinal cord lesions were detected in 17 (46%) of these 37 cases on MRI. The cervical cord lesions were more detectable than other spinal cord lesions. At the thoracic level, the upper lesions were more detectable than the lower ones. In this study, no correlation was found between the disease duration, the rate of functional disturbance and the detectable rate of spinal cord lesions. The characteristic findings of the lesions were swelling and the enhancement effect of Gd-DTPA in the patient group with a disease duration of less than three years, and atrophic change in the patient group with a disease duration of greater than seven years. The period of the enhancement effect of Gd-DTPA varied in each case, and it may reflect the clinical course. Syrinx-like lesions were found in four cases. In one of them, atrophic change was found in the same region six months after the follow up study. Although the precise reason for the syrinx-like lesion was unclear, a relationship between syrinx-like lesion and atrophy of the spinal cord was suggested. The MRI findings of the spinal cord lesions in MS varied in each case and in each stage of the disease. (author)

  15. A level set method for multiple sclerosis lesion segmentation.

    Science.gov (United States)

    Zhao, Yue; Guo, Shuxu; Luo, Min; Shi, Xue; Bilello, Michel; Zhang, Shaoxiang; Li, Chunming

    2018-06-01

    In this paper, we present a level set method for multiple sclerosis (MS) lesion segmentation from FLAIR images in the presence of intensity inhomogeneities. We use a three-phase level set formulation of segmentation and bias field estimation to segment MS lesions and normal tissue region (including GM and WM) and CSF and the background from FLAIR images. To save computational load, we derive a two-phase formulation from the original multi-phase level set formulation to segment the MS lesions and normal tissue regions. The derived method inherits the desirable ability to precisely locate object boundaries of the original level set method, which simultaneously performs segmentation and estimation of the bias field to deal with intensity inhomogeneity. Experimental results demonstrate the advantages of our method over other state-of-the-art methods in terms of segmentation accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Volume measurement of multiple sclerosis lesions with magnetic resonance images

    International Nuclear Information System (INIS)

    Wicks, D.A.G.; Tofts, P.S.; Miller, D.H.; Du Boulay, G.H.; Feinstein, A.; Harvey, I.; Brenner, R.; McDonald, W.I.; Sacares, R.P.

    1992-01-01

    The ability to visualise multiple sclerosis lesions in vivo with magnetic resonance imaging suggests an important role in monitoring the course of the disease. In order to help the long-term assessment of prospective treatments, a semi-automated technique for measuring lesion volume has been developed to provide a quantitative index of disease progression. Results are presented from a preliminary study with a single patient and compared to measurements taken from lesion outlines traced by a neuroradiologist, two neurologists and a technician. The semi-automated technique achieved a precision of 6% compared to a range of 12-33% for the manual tracing method. It also reduced the human interaction time from at least 60 min to 15 min. (orig.)

  17. Characteristics of lesional and extra-lesional cortical grey matter in relapsing-remitting and secondary progressive multiple sclerosis: A magnetisation transfer and diffusion tensor imaging study.

    Science.gov (United States)

    Yaldizli, Özgür; Pardini, Matteo; Sethi, Varun; Muhlert, Nils; Liu, Zheng; Tozer, Daniel J; Samson, Rebecca S; Wheeler-Kingshott, Claudia Am; Yousry, Tarek A; Miller, David H; Chard, Declan T

    2016-02-01

    In multiple sclerosis (MS), diffusion tensor and magnetisation transfer imaging are both abnormal in lesional and extra-lesional cortical grey matter, but differences between clinical subtypes and associations with clinical outcomes have only been partly assessed. To compare mean diffusivity, fractional anisotropy and magnetisation transfer ratio (MTR) in cortical grey matter lesions (detected using phase-sensitive inversion recovery (PSIR) imaging) and extra-lesional cortical grey matter, and assess associations with disability in relapse-onset MS. Seventy-two people with MS (46 relapsing-remitting (RR), 26 secondary progressive (SP)) and 36 healthy controls were included in this study. MTR, mean diffusivity and fractional anisotropy were measured in lesional and extra-lesional cortical grey matter. Mean fractional anisotropy was higher and MTR lower in lesional compared with extra-lesional cortical grey matter. In extra-lesional cortical grey matter mean fractional anisotropy and MTR were lower, and mean diffusivity was higher in the MS group compared with controls. Mean MTR was lower and mean diffusivity was higher in lesional and extra-lesional cortical grey matter in SPMS when compared with RRMS. These differences were independent of disease duration. In multivariate analyses, MTR in extra-lesional more so than lesional cortical grey matter was associated with disability. Magnetic resonance abnormalities in lesional and extra-lesional cortical grey matter are greater in SPMS than RRMS. Changes in extra-lesional compared with lesional cortical grey matter are more consistently associated with disability. © The Author(s), 2015.

  18. Robust segmentation of focal lesions on multi-sequence MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Garcia-Lorenzo, Daniel

    2010-01-01

    Multiple sclerosis (MS) affects around 80.000 people in France. Magnetic resonance imaging (MRI) is an essential tool for diagnosis of MS and MRI-derived surrogate markers such as MS lesion volumes are often used as measures in MS clinical trials for the development of new treatments. The manual segmentation of these MS lesions is a time-consuming task that shows high inter- and intra-rater variability. We developed an automatic work flow for the segmentation of focal MS lesions on MRI. The segmentation method is based on the robust estimation of a parametric model of the intensities of the brain; lesions are detected as outliers to the model. We proposed two methods to include spatial information in the segmentation using mean shift and graph cut. We performed a quantitative evaluation of our work flow using synthetic and clinical images of two different centers to verify its accuracy and robustness. (author)

  19. Classification of multiple sclerosis lesions using adaptive dictionary learning.

    Science.gov (United States)

    Deshpande, Hrishikesh; Maurel, Pierre; Barillot, Christian

    2015-12-01

    This paper presents a sparse representation and an adaptive dictionary learning based method for automated classification of multiple sclerosis (MS) lesions in magnetic resonance (MR) images. Manual delineation of MS lesions is a time-consuming task, requiring neuroradiology experts to analyze huge volume of MR data. This, in addition to the high intra- and inter-observer variability necessitates the requirement of automated MS lesion classification methods. Among many image representation models and classification methods that can be used for such purpose, we investigate the use of sparse modeling. In the recent years, sparse representation has evolved as a tool in modeling data using a few basis elements of an over-complete dictionary and has found applications in many image processing tasks including classification. We propose a supervised classification approach by learning dictionaries specific to the lesions and individual healthy brain tissues, which include white matter (WM), gray matter (GM) and cerebrospinal fluid (CSF). The size of the dictionaries learned for each class plays a major role in data representation but it is an even more crucial element in the case of competitive classification. Our approach adapts the size of the dictionary for each class, depending on the complexity of the underlying data. The algorithm is validated using 52 multi-sequence MR images acquired from 13 MS patients. The results demonstrate the effectiveness of our approach in MS lesion classification. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Calcified neurocysticercosis lesions and hippocampal sclerosis: potential dual pathology?

    Science.gov (United States)

    Rathore, Chaturbhuj; Thomas, Bejoy; Kesavadas, Chandrasekharan; Radhakrishnan, Kurupath

    2012-04-01

    In areas where cysticercosis is endemic, calcified neurocysticercosis lesion(s) (CNL) and hippocampal sclerosis (HS) commonly coexist in patients with localization-related epilepsies. To understand the pathogenesis of HS associated with CNL, we compared the characteristics of three groups of patients with antiepileptic drug-resistant epilepsies: CNL with HS, CNL without HS (CNL alone), and HS without CNL (HS alone). In comparison to patients with CNL alone, those with CNL with HS had CNL more frequently located in the ipsilateral temporal lobe. Those with CNL with HS had a lower incidence of febrile seizures, older age at initial precipitating injury and at onset of habitual complex partial seizures, and more frequent clustering of seizures and extratemporal/bitemporal interictal epileptiform discharges as compared to patients with HS alone. Our study illustrates that HS associated with CNL might have a different pathophysiologic basis as compared to classical HS. Wiley Periodicals, Inc. © 2012 International League Against Epilepsy.

  1. The development of an MRI lesion quantifying system for multiple sclerosis patients undergoing treatment

    Science.gov (United States)

    Moin, Paymann; Ma, Kevin; Amezcua, Lilyana; Gertych, Arkadiusz; Liu, Brent

    2009-02-01

    Multiple sclerosis (MS) is a demyelinating disease of the central nervous system that affects approximately 2.5 million people worldwide. Magnetic resonance imaging (MRI) is an established tool for the assessment of disease activity, progression and response to treatment. The progression of the disease is variable and requires routine follow-up imaging studies. Currently, MRI quantification of multiple sclerosis requires a manual approach to lesion measurement and yields an estimate of lesion volume and interval change. In the setting of several prior studies and a long treatment history, trends related to treatment change quickly become difficult to extrapolate. Our efforts seek to develop an imaging informatics based MS lesion computer aided detection (CAD) package to quantify and track MS lesions including lesion load, volume, and location. Together, with select clinical parameters, this data will be incorporated into an MS specific e- Folder to provide decision support to evaluate and assess treatment options for MS in a manner tailored specifically to an individual based on trends in MS presentation and progression.

  2. Heterogeneity of Multiple Sclerosis Lesions in Multislice Myelin Water Imaging.

    Directory of Open Access Journals (Sweden)

    Tobias Djamsched Faizy

    Full Text Available To assess neuroprotection and remyelination in Multiple Sclerosis (MS, we applied a more robust myelin water imaging (MWI processing technique, including spatial priors into image reconstruction, which allows for lower SNR, less averages and shorter acquisition times. We sought to evaluate this technique in MS-patients and healthy controls (HC.Seventeen MS-patients and 14 age-matched HCs received a 3T Magnetic Resonance Imaging (MRI examination including MWI (8 slices, 12 minutes acquisition time, T2w and T1mprage pre and post gadolinium (GD administration. Black holes (BH, contrast enhancing lesions (CEL and T2 lesions were marked and registered to MWI. Additionally, regions of interest (ROI were defined in the frontal, parietal and occipital normal appearing white matter (NAWM/white matter (WM, the corticospinal tract (CST, the splenium (SCC and genu (GCC of the corpus callosum in patients and HCs. Mean values of myelin water fraction (MWF were determined for each ROI.Significant differences (p≤0.05 of the MWF were found in all three different MS-lesion types (BH, CEL, T2 lesions, compared to the WM of HCs. The mean MWF values among the different lesion types were significantly differing from each other. Comparing MS-patients vs. HCs, we found a significant (p≤0.05 difference of the MWF in all measured ROIs except of GCC and SCC. The mean reduction of MWF in the NAWM of MS-patients compared to HCs was 37%. No age, sex, disability score and disease duration dependency was found for the NAWM MWF.MWF measures were in line with previous studies and lesions were clearly visible in MWI. MWI allows for quantitative assessment of NAWM and lesions in MS, which could be used as an additional sensitive imaging endpoint for larger MS studies. Measurements of the MWF also differ between patients and healthy controls.

  3. Automatic segmentation and volumetry of multiple sclerosis brain lesions from MR images

    Directory of Open Access Journals (Sweden)

    Saurabh Jain

    2015-01-01

    Full Text Available The location and extent of white matter lesions on magnetic resonance imaging (MRI are important criteria for diagnosis, follow-up and prognosis of multiple sclerosis (MS. Clinical trials have shown that quantitative values, such as lesion volumes, are meaningful in MS prognosis. Manual lesion delineation for the segmentation of lesions is, however, time-consuming and suffers from observer variability. In this paper, we propose MSmetrix, an accurate and reliable automatic method for lesion segmentation based on MRI, independent of scanner or acquisition protocol and without requiring any training data. In MSmetrix, 3D T1-weighted and FLAIR MR images are used in a probabilistic model to detect white matter (WM lesions as an outlier to normal brain while segmenting the brain tissue into grey matter, WM and cerebrospinal fluid. The actual lesion segmentation is performed based on prior knowledge about the location (within WM and the appearance (hyperintense on FLAIR of lesions. The accuracy of MSmetrix is evaluated by comparing its output with expert reference segmentations of 20 MRI datasets of MS patients. Spatial overlap (Dice between the MSmetrix and the expert lesion segmentation is 0.67 ± 0.11. The intraclass correlation coefficient (ICC equals 0.8 indicating a good volumetric agreement between the MSmetrix and expert labelling. The reproducibility of MSmetrix' lesion volumes is evaluated based on 10 MS patients, scanned twice with a short interval on three different scanners. The agreement between the first and the second scan on each scanner is evaluated through the spatial overlap and absolute lesion volume difference between them. The spatial overlap was 0.69 ± 0.14 and absolute total lesion volume difference between the two scans was 0.54 ± 0.58 ml. Finally, the accuracy and reproducibility of MSmetrix compare favourably with other publicly available MS lesion segmentation algorithms, applied on the same data using default

  4. SWI enhances vein detection using gadolinium in multiple sclerosis

    International Nuclear Information System (INIS)

    Maggi, Pietro; Mazzoni, Lorenzo N; Moretti, Marco; Grammatico, Matteo; Chiti, Stefano; Massacesi, Luca

    2015-01-01

    Susceptibility weighted imaging (SWI) combined with the FLAIR sequence provides the ability to depict in vivo the perivenous location of inflammatory demyelinating lesions – one of the most specific pathologic features of multiple sclerosis (MS). In addition, in MS white matter (WM) lesions, gadolinium-based contrast media (CM) can increase vein signal loss on SWI. This report focuses on two cases of WM inflammatory lesions enhancing on SWI images after CM injection. In these lesions in fact the CM increased the contrast between the parenchyma and the central vein allowing as well, in one of the two cases, the detection of a vein not visible on the same SWI sequence acquired before CM injection

  5. OASIS is Automated Statistical Inference for Segmentation, with applications to multiple sclerosis lesion segmentation in MRI.

    Science.gov (United States)

    Sweeney, Elizabeth M; Shinohara, Russell T; Shiee, Navid; Mateen, Farrah J; Chudgar, Avni A; Cuzzocreo, Jennifer L; Calabresi, Peter A; Pham, Dzung L; Reich, Daniel S; Crainiceanu, Ciprian M

    2013-01-01

    Magnetic resonance imaging (MRI) can be used to detect lesions in the brains of multiple sclerosis (MS) patients and is essential for diagnosing the disease and monitoring its progression. In practice, lesion load is often quantified by either manual or semi-automated segmentation of MRI, which is time-consuming, costly, and associated with large inter- and intra-observer variability. We propose OASIS is Automated Statistical Inference for Segmentation (OASIS), an automated statistical method for segmenting MS lesions in MRI studies. We use logistic regression models incorporating multiple MRI modalities to estimate voxel-level probabilities of lesion presence. Intensity-normalized T1-weighted, T2-weighted, fluid-attenuated inversion recovery and proton density volumes from 131 MRI studies (98 MS subjects, 33 healthy subjects) with manual lesion segmentations were used to train and validate our model. Within this set, OASIS detected lesions with a partial area under the receiver operating characteristic curve for clinically relevant false positive rates of 1% and below of 0.59% (95% CI; [0.50%, 0.67%]) at the voxel level. An experienced MS neuroradiologist compared these segmentations to those produced by LesionTOADS, an image segmentation software that provides segmentation of both lesions and normal brain structures. For lesions, OASIS out-performed LesionTOADS in 74% (95% CI: [65%, 82%]) of cases for the 98 MS subjects. To further validate the method, we applied OASIS to 169 MRI studies acquired at a separate center. The neuroradiologist again compared the OASIS segmentations to those from LesionTOADS. For lesions, OASIS ranked higher than LesionTOADS in 77% (95% CI: [71%, 83%]) of cases. For a randomly selected subset of 50 of these studies, one additional radiologist and one neurologist also scored the images. Within this set, the neuroradiologist ranked OASIS higher than LesionTOADS in 76% (95% CI: [64%, 88%]) of cases, the neurologist 66% (95% CI: [52%, 78

  6. Small white matter lesion detection in cerebral small vessel disease

    Science.gov (United States)

    Ghafoorian, Mohsen; Karssemeijer, Nico; van Uden, Inge; de Leeuw, Frank E.; Heskes, Tom; Marchiori, Elena; Platel, Bram

    2015-03-01

    Cerebral small vessel disease (SVD) is a common finding on magnetic resonance images of elderly people. White matter lesions (WML) are important markers for not only the small vessel disease, but also neuro-degenerative diseases including multiple sclerosis, Alzheimer's disease and vascular dementia. Volumetric measurements such as the "total lesion load", have been studied and related to these diseases. With respect to SVD we conjecture that small lesions are important, as they have been observed to grow over time and they form the majority of lesions in number. To study these small lesions they need to be annotated, which is a complex and time-consuming task. Existing (semi) automatic methods have been aimed at volumetric measurements and large lesions, and are not suitable for the detection of small lesions. In this research we established a supervised voxel classification CAD system, optimized and trained to exclusively detect small WMLs. To achieve this, several preprocessing steps were taken, which included a robust standardization of subject intensities to reduce inter-subject intensity variability as much as possible. A number of features that were found to be well identifying small lesions were calculated including multimodal intensities, tissue probabilities, several features for accurate location description, a number of second order derivative features as well as multi-scale annular filter for blobness detection. Only small lesions were used to learn the target concept via Adaboost using random forests as its basic classifiers. Finally the results were evaluated using Free-response receiver operating characteristic.

  7. Multiple sclerosis

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Kuehn, A.L.; Backens, M.; Papanagiotou, P.; Shariat, K.; Kostopoulos, P.

    2008-01-01

    Multiple sclerosis is the most common chronic inflammatory disease of myelin with interspersed lesions in the white matter of the central nervous system. Magnetic resonance imaging (MRI) plays a key role in the diagnosis and monitoring of white matter diseases. This article focuses on key findings in multiple sclerosis as detected by MRI. (orig.) [de

  8. Imaging inflammatory acne: lesion detection and tracking

    Science.gov (United States)

    Cula, Gabriela O.; Bargo, Paulo R.; Kollias, Nikiforos

    2010-02-01

    It is known that effectiveness of acne treatment increases when the lesions are detected earlier, before they could progress into mature wound-like lesions, which lead to scarring and discoloration. However, little is known about the evolution of acne from early signs until after the lesion heals. In this work we computationally characterize the evolution of inflammatory acne lesions, based on analyzing cross-polarized images that document acne-prone facial skin over time. Taking skin images over time, and being able to follow skin features in these images present serious challenges, due to change in the appearance of skin, difficulty in repositioning the subject, involuntary movement such as breathing. A computational technique for automatic detection of lesions by separating the background normal skin from the acne lesions, based on fitting Gaussian distributions to the intensity histograms, is presented. In order to track and quantify the evolution of lesions, in terms of the degree of progress or regress, we designed a study to capture facial skin images from an acne-prone young individual, followed over the course of 3 different time points. Based on the behavior of the lesions between two consecutive time points, the automatically detected lesions are classified in four categories: new lesions, resolved lesions (i.e. lesions that disappear completely), lesions that are progressing, and lesions that are regressing (i.e. lesions in the process of healing). The classification our methods achieve correlates well with visual inspection of a trained human grader.

  9. Fibronectin aggregation in multiple sclerosis lesions impairs remyelination

    NARCIS (Netherlands)

    Stoffels, J.M.J.; de Jonge, J.C.; Stancic, M.; Nomden, A.; van Strien, M.E.; Ma, D.; Siskova, Z.; Maier, O.; Ffrench-Constant, C.; Franklin, R.J.M.; Hoekstra, D.; Zhao, C.; Baron, W.

    2013-01-01

    Remyelination following central nervous system demyelination is essential to prevent axon degeneration. However, remyelination ultimately fails in demyelinating diseases such as multiple sclerosis. This failure of remyelination is likely mediated by many factors, including changes in the

  10. Fibronectin aggregation in multiple sclerosis lesions impairs remyelination

    NARCIS (Netherlands)

    Stoffels, Josephine M. J.; de Jonge, Jenny C.; Stancic, Mirjana; Nomden, Anita; van Strien, Miriam E.; Ma, Dan; Siskova, Zuzana; Maier, Olaf; Ffrench-Constant, Charles; Franklin, Robin J. M.; Hoekstra, Dick; Zhao, Chao; Baron, Wia

    Remyelination following central nervous system demyelination is essential to prevent axon degeneration. However, remyelination ultimately fails in demyelinating diseases such as multiple sclerosis. This failure of remyelination is likely mediated by many factors, including changes in the

  11. The effect of venous anatomy on the morphology of multiple sclerosis lesions: a susceptibility-weighted imaging study

    International Nuclear Information System (INIS)

    Öztoprak, B.; Öztoprak, İ.; Yıldız, Ö.K.

    2016-01-01

    Aim: To investigate the cause of morphology in non-ovoid multiple sclerosis (MS) lesions lacking a radial course and typical shape. Materials and methods: Non-ovoid atypical lesions without perpendicular extensions to the ventricle were investigated in 95 MS patients by retrospective examination of T2-weighted and fluid-attenuated inversion recovery (FLAIR) images. The relationship between the morphology of these atypical lesions detected in 38 patients and central vein anatomy was examined using susceptibility-weighted imaging (SWI). Results: A central venous structure was observed in 107 (65.6%) of 163 atypical lesions in 38 patients. The distribution of atypical lesions grouped by their shape was as follows: (1) V- or Y-shaped lesions (n=27, 48.6%) were observed where veins bifurcated; (2) crescent-shaped lesions (n=9, 8.4%) were observed where veins formed an arc; (3) patchy lesions comprised 48.6% (n=52) of the atypical lesions and involved multiple medullary veins or medullary veins showing a “caput medusae” distribution; (4) ovoid lesions with a non-radial course (n=19, 17.7%) were generally observed where medullary veins converged to form internal cerebral vein branches. Conclusion: Unlike typical MS plaques, non-ovoid atypical lesions make the differential diagnosis of MS challenging. Demonstration of the relationship between venous anatomy and lesion morphology in atypical lesions using SWI will aid in the differential diagnosis. - Highlights: • Morphology of MS lesions are associated with the orientation of central veins. • SWI shows venous anatomy and anatomic variations in MS lesions. • Association between vein and T2-hyperintensity may aid in differential diagnosis.

  12. Characterization of microcirculation in multiple sclerosis lesions by dynamic texture parameter analysis (DTPA.

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar Verma

    Full Text Available OBJECTIVE: Texture analysis is an alternative method to quantitatively assess MR-images. In this study, we introduce dynamic texture parameter analysis (DTPA, a novel technique to investigate the temporal evolution of texture parameters using dynamic susceptibility contrast enhanced (DSCE imaging. Here, we aim to introduce the method and its application on enhancing lesions (EL, non-enhancing lesions (NEL and normal appearing white matter (NAWM in multiple sclerosis (MS. METHODS: We investigated 18 patients with MS and clinical isolated syndrome (CIS, according to the 2010 McDonald's criteria using DSCE imaging at different field strengths (1.5 and 3 Tesla. Tissues of interest (TOIs were defined within 27 EL, 29 NEL and 37 NAWM areas after normalization and eight histogram-based texture parameter maps (TPMs were computed. TPMs quantify the heterogeneity of the TOI. For every TOI, the average, variance, skewness, kurtosis and variance-of-the-variance statistical parameters were calculated. These TOI parameters were further analyzed using one-way ANOVA followed by multiple Wilcoxon sum rank testing corrected for multiple comparisons. RESULTS: Tissue- and time-dependent differences were observed in the dynamics of computed texture parameters. Sixteen parameters discriminated between EL, NEL and NAWM (pAVG = 0.0005. Significant differences in the DTPA texture maps were found during inflow (52 parameters, outflow (40 parameters and reperfusion (62 parameters. The strongest discriminators among the TPMs were observed in the variance-related parameters, while skewness and kurtosis TPMs were in general less sensitive to detect differences between the tissues. CONCLUSION: DTPA of DSCE image time series revealed characteristic time responses for ELs, NELs and NAWM. This may be further used for a refined quantitative grading of MS lesions during their evolution from acute to chronic state. DTPA discriminates lesions beyond features of enhancement or T2

  13. Thalamic lesions in multiple sclerosis by 7T MRI: Clinical implications and relationship to cortical pathology.

    Science.gov (United States)

    Harrison, Daniel M; Oh, Jiwon; Roy, Snehashis; Wood, Emily T; Whetstone, Anna; Seigo, Michaela A; Jones, Craig K; Pham, Dzung; van Zijl, Peter; Reich, Daniel S; Calabresi, Peter A

    2015-08-01

    Pathology in both cortex and deep gray matter contribute to disability in multiple sclerosis (MS). We used the increased signal-to-noise ratio of 7-tesla (7T) MRI to visualize small lesions within the thalamus and to relate this to clinical information and cortical lesions. We obtained 7T MRI scans on 34 MS cases and 15 healthy volunteers. Thalamic lesion number and volume were related to demographic data, clinical disability measures, and lesions in cortical gray matter. Thalamic lesions were found in 24/34 of MS cases. Two lesion subtypes were noted: discrete, ovoid lesions, and more diffuse lesional areas lining the periventricular surface. The number of thalamic lesions was greater in progressive MS compared to relapsing-remitting (mean ±SD, 10.7 ±0.7 vs. 3.0 ±0.7, respectively, p < 0.001). Thalamic lesion burden (count and volume) correlated with EDSS score and measures of cortical lesion burden, but not with white matter lesion burden or white matter volume. Using 7T MRI allows identification of thalamic lesions in MS, which are associated with disability, progressive disease, and cortical lesions. Thalamic lesion analysis may be a simpler, more rapid estimate of overall gray matter lesion burden in MS. © The Author(s), 2015.

  14. Multiple sclerosis : Mechanisms of myelin phagocytosis and lesion expansion

    NARCIS (Netherlands)

    Hendrickx, D.A.E.

    2018-01-01

    Multiple sclerosis (MS) is characterized by immune activation and focal demyelination in the central nervous system. The aim of this thesis was to gain more insight into the mechanisms of myelin phagocytosis by resident microglia and infiltrating macrophages. We first evaluated the expression of the

  15. Detection of Fundus Lesions Using Classifier Selection

    Science.gov (United States)

    Nagayoshi, Hiroto; Hiramatsu, Yoshitaka; Sako, Hiroshi; Himaga, Mitsutoshi; Kato, Satoshi

    A system for detecting fundus lesions caused by diabetic retinopathy from fundus images is being developed. The system can screen the images in advance in order to reduce the inspection workload on doctors. One of the difficulties that must be addressed in completing this system is how to remove false positives (which tend to arise near blood vessels) without decreasing the detection rate of lesions in other areas. To overcome this difficulty, we developed classifier selection according to the position of a candidate lesion, and we introduced new features that can distinguish true lesions from false positives. A system incorporating classifier selection and these new features was tested in experiments using 55 fundus images with some lesions and 223 images without lesions. The results of the experiments confirm the effectiveness of the proposed system, namely, degrees of sensitivity and specificity of 98% and 81%, respectively.

  16. Effects on Cognition of Stereotactic Lesional Surgery For the Treatment of Tremor in Multiple Sclerosis

    Science.gov (United States)

    Jahanshahi, Marjan; Pieter, Socorro; Alusi, Sundus H.; Jones, Catherine R. G.; Glickman, Scott; Stein, John; Aziz, Tipu; Bain, Peter G.

    2008-01-01

    Objective: To assess the effect of stereotactic lesional surgery for treatment of tremor in multiple sclerosis on cognition. Methods: Eleven patients (3 males, 8 females) with multiple sclerosis participated in the study. Six subjects comprised the surgical group and five the matched control group. All patients were assessed at baseline and three months using a neuropsychological test battery that included measures of intellectual ability, memory, language, perception and executive function. Results: There were no significant differences between the surgical and control groups and no change from pre to post testing except for a decline in scores on the Mini-Mental State Examination (MMSE), WAIS-R Digit Span and Verbal Fluency in the surgical group. Conclusions: The results indicate that stereotactic lesional surgery does not result in major cognitive impairment in multiple sclerosis. However, the decline in MMSE scores, digit span and verbal fluency require further investigation in a larger sample. PMID:19491469

  17. Postmortem verification of MS cortical lesion detection with 3D DIR

    NARCIS (Netherlands)

    Seewann, A.M.; Kooi, E.J.; Roosendaal, S.D.; Pouwels, P.J.W.; Wattjes, M.P.; van der Valk, P.; Barkhof, F.; Polman, C.H.; Geurts, J.J.G.

    2012-01-01

    Objective: To assess the sensitivity and specificity of 3D double inversion recovery (DIR) MRI for detecting multiple sclerosis (MS) cortical lesions (CLs) using a direct postmortem MRI to histopathology comparison. Methods: Single-slab 3D DIR and 3D fluid-attenuated inversion recovery (FLAIR)

  18. Fingolimod in active multiple sclerosis: an impressive decrease in Gd-enhancing lesions

    NARCIS (Netherlands)

    Muris, A.H.; Rolf, L.; Damoiseaux, J.; Koeman, E.; Hupperts, R.

    2014-01-01

    Background: Fingolimod is a disease modifying therapy (DMT) in highly active relapsing remitting multiple sclerosis (RRMS), as is natalizumab. Fingolimod decreases annual relapse rates and gadolinium enhancing lesions on MRI as compared to either interferon beta (IFNβ) or placebo. The effect of

  19. Segmenting Multiple Sclerosis Lesions using a Spatially Constrained K-Nearest Neighbour approach

    DEFF Research Database (Denmark)

    Lyksborg, Mark; Larsen, Rasmus; Sørensen, Per Soelberg

    2012-01-01

    We propose a method for the segmentation of Multiple Sclerosis lesions. The method is based on probability maps derived from a K-Nearest Neighbours classication. These are used as a non parametric likelihood in a Bayesian formulation with a prior that assumes connectivity of neighbouring voxels. ...

  20. Generation of connectivity-preserving surface models of multiple sclerosis lesions.

    Science.gov (United States)

    Meruvia-Pastor, Oscar; Xiao, Mei; Soh, Jung; Sensen, Christoph W

    2011-01-01

    Progression of multiple sclerosis (MS) results in brain lesions caused by white matter inflammation. MS lesions have various shapes, sizes and locations, affecting cognitive abilities of patients to different extents. To facilitate the visualization of the brain lesion distribution, we have developed a software tool to build 3D surface models of MS lesions. This tool allows users to create 3D models of lesions quickly and to visualize the lesions and brain tissues using various visual attributes and configurations. The software package is based on breadth-first search based 3D connected component analysis and a 3D flood-fill based region growing algorithm to generate 3D models from binary or non-binary segmented medical image stacks.

  1. MRI of paraventricular white matter lesions in amyotrophic lateral sclerosis. Analysis by diffusion-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Segawa, Fuminori; Kinoshita, Masao (Toho Univ., Tokyo (Japan). Ohashi Hospital); Kishibayashi, Jun; Kamada, Kazuhiko; Sunohara, Nobuhiko

    1994-09-01

    Magnetic resonance images in some cases of amyotrophic lateral sclerosis (ALS) revealed abnormal signals in both the paraventriculer white matter and in the posterior limbs of the internal capsule. We examined T[sub 2]- and diffusion-weighted MR images of these lesions in 18 cases of ALS. There were symmetrical high-signal areas in the posterior limbs of the internal capsule in all of the cases. The high-signal areas in the internal capsule corresponded to the pyramidal tracts in the anatomical atlas by Talairach. In 5 of the cases of ALS, T[sub 2]-weighted MR images showed discrete paraventricular white matter lesions as well. The mean age of the ALS patients with paraventricular white matter lesions was higher than that of the ALS patients without such lesions. Proton densities calculated from the conventional MR images were higher in both the capsular and paraventricular lesions. The diffusion coefficients perpendicular to the pyramidal tract in the internal capsular lesions were within the normal range, where as the diffusion coefficients in the paraventricular lesions were increased in all directions. Thus, diffusion anisotropy was lost in the paraventricular lesions. These findings are similar to those observed in the white matter lesions of cerebro-vascular origin. As a result, the pathology of the paraventricular lesions in ALS was confirmed to be different from that of the internal capsular lesions. (author).

  2. MRI of paraventricular white matter lesions in amyotrophic lateral sclerosis. Analysis by diffusion-weighted images

    International Nuclear Information System (INIS)

    Segawa, Fuminori; Kinoshita, Masao; Kishibayashi, Jun; Kamada, Kazuhiko; Sunohara, Nobuhiko.

    1994-01-01

    Magnetic resonance images in some cases of amyotrophic lateral sclerosis (ALS) revealed abnormal signals in both the paraventriculer white matter and in the posterior limbs of the internal capsule. We examined T 2 - and diffusion-weighted MR images of these lesions in 18 cases of ALS. There were symmetrical high-signal areas in the posterior limbs of the internal capsule in all of the cases. The high-signal areas in the internal capsule corresponded to the pyramidal tracts in the anatomical atlas by Talairach. In 5 of the cases of ALS, T 2 -weighted MR images showed discrete paraventricular white matter lesions as well. The mean age of the ALS patients with paraventricular white matter lesions was higher than that of the ALS patients without such lesions. Proton densities calculated from the conventional MR images were higher in both the capsular and paraventricular lesions. The diffusion coefficients perpendicular to the pyramidal tract in the internal capsular lesions were within the normal range, where as the diffusion coefficients in the paraventricular lesions were increased in all directions. Thus, diffusion anisotropy was lost in the paraventricular lesions. These findings are similar to those observed in the white matter lesions of cerebro-vascular origin. As a result, the pathology of the paraventricular lesions in ALS was confirmed to be different from that of the internal capsular lesions. (author)

  3. Performance evaluation for volumetric segmentation of multiple sclerosis lesions using MATLAB and computing engine in the graphical processing unit (GPU)

    Science.gov (United States)

    Le, Anh H.; Park, Young W.; Ma, Kevin; Jacobs, Colin; Liu, Brent J.

    2010-03-01

    Multiple Sclerosis (MS) is a progressive neurological disease affecting myelin pathways in the brain. Multiple lesions in the white matter can cause paralysis and severe motor disabilities of the affected patient. To solve the issue of inconsistency and user-dependency in manual lesion measurement of MRI, we have proposed a 3-D automated lesion quantification algorithm to enable objective and efficient lesion volume tracking. The computer-aided detection (CAD) of MS, written in MATLAB, utilizes K-Nearest Neighbors (KNN) method to compute the probability of lesions on a per-voxel basis. Despite the highly optimized algorithm of imaging processing that is used in CAD development, MS CAD integration and evaluation in clinical workflow is technically challenging due to the requirement of high computation rates and memory bandwidth in the recursive nature of the algorithm. In this paper, we present the development and evaluation of using a computing engine in the graphical processing unit (GPU) with MATLAB for segmentation of MS lesions. The paper investigates the utilization of a high-end GPU for parallel computing of KNN in the MATLAB environment to improve algorithm performance. The integration is accomplished using NVIDIA's CUDA developmental toolkit for MATLAB. The results of this study will validate the practicality and effectiveness of the prototype MS CAD in a clinical setting. The GPU method may allow MS CAD to rapidly integrate in an electronic patient record or any disease-centric health care system.

  4. Multi-output decision trees for lesion segmentation in multiple sclerosis

    Science.gov (United States)

    Jog, Amod; Carass, Aaron; Pham, Dzung L.; Prince, Jerry L.

    2015-03-01

    Multiple Sclerosis (MS) is a disease of the central nervous system in which the protective myelin sheath of the neurons is damaged. MS leads to the formation of lesions, predominantly in the white matter of the brain and the spinal cord. The number and volume of lesions visible in magnetic resonance (MR) imaging (MRI) are important criteria for diagnosing and tracking the progression of MS. Locating and delineating lesions manually requires the tedious and expensive efforts of highly trained raters. In this paper, we propose an automated algorithm to segment lesions in MR images using multi-output decision trees. We evaluated our algorithm on the publicly available MICCAI 2008 MS Lesion Segmentation Challenge training dataset of 20 subjects, and showed improved results in comparison to state-of-the-art methods. We also evaluated our algorithm on an in-house dataset of 49 subjects with a true positive rate of 0.41 and a positive predictive value 0.36.

  5. Optoacoustic detection of thermal lesions

    Science.gov (United States)

    Arsenault, Michel G.; Kolios, Michael C.; Whelan, William M.

    2009-02-01

    Minimally invasive thermal therapy is being investigated as an alternative cancer treatment. It involves heating tissues to greater than 55°C over a period of a few minutes, which results in tissue coagulation. Optoacoustic (OA) imaging is a new imaging technique that involves exposing tissues to pulsed light and detecting the acoustic waves that are generated. In this study, adult bovine liver tissue samples were heated using continuous wave laser energy for various times, then scanned using an optoacoustic imaging system. Large optoacoustic signal variability was observed in the native tissue prior to heating. OA signal amplitude increased with maximum tissue temperature achieved, characterized by a correlation coefficient of 0.63. In this study we show that there are detectable changes in optoacoustic signal strength that arise from tissue coagulation, which demonstrates the potential of optoacoustic technology for the monitoring of thermal therapy delivery.

  6. Quantifying brain tissue volume in multiple sclerosis with automated lesion segmentation and filling

    Directory of Open Access Journals (Sweden)

    Sergi Valverde

    2015-01-01

    Full Text Available Lesion filling has been successfully applied to reduce the effect of hypo-intense T1-w Multiple Sclerosis (MS lesions on automatic brain tissue segmentation. However, a study of fully automated pipelines incorporating lesion segmentation and lesion filling on tissue volume analysis has not yet been performed. Here, we analyzed the % of error introduced by automating the lesion segmentation and filling processes in the tissue segmentation of 70 clinically isolated syndrome patient images. First of all, images were processed using the LST and SLS toolkits with different pipeline combinations that differed in either automated or manual lesion segmentation, and lesion filling or masking out lesions. Then, images processed following each of the pipelines were segmented into gray matter (GM and white matter (WM using SPM8, and compared with the same images where expert lesion annotations were filled before segmentation. Our results showed that fully automated lesion segmentation and filling pipelines reduced significantly the % of error in GM and WM volume on images of MS patients, and performed similarly to the images where expert lesion annotations were masked before segmentation. In all the pipelines, the amount of misclassified lesion voxels was the main cause in the observed error in GM and WM volume. However, the % of error was significantly lower when automatically estimated lesions were filled and not masked before segmentation. These results are relevant and suggest that LST and SLS toolboxes allow the performance of accurate brain tissue volume measurements without any kind of manual intervention, which can be convenient not only in terms of time and economic costs, but also to avoid the inherent intra/inter variability between manual annotations.

  7. Small calcified lesions suggestive of neurocysticercosis are associated with mesial temporal sclerosis

    Directory of Open Access Journals (Sweden)

    Marcos C. B. Oliveira

    2014-07-01

    Full Text Available Recent studies have suggested a possible relationship between temporal lobe epilepsy with mesial temporal sclerosis (MTS and neurocysticercosis (NC. We performed a case-control study to evaluate the association of NC and MTS. Method: We randomly selected patients with different epilepsy types, including: MTS, primary generalized epilepsy (PGE and focal symptomatic epilepsy (FSE. Patients underwent a structured interview, followed by head computed tomography (CT. A neuroradiologist evaluated the scan for presence of calcified lesions suggestive of NC. CT results were matched with patients’ data. Results: More patients in the MTS group displayed calcified lesions suggestive of NC than patients in the other groups (p=0.002. On multivariate analysis, MTS was found to be an independent predictor of one or more calcified NC lesions (p=0.033. Conclusion: After controlling for confounding factors, we found an independent association between NC calcified lesions and MTS.

  8. Location of brain lesions predicts conversion of clinically isolated syndromes to multiple sclerosis

    DEFF Research Database (Denmark)

    Giorgio, Antonio; Battaglini, Marco; Rocca, Maria Assunta

    2013-01-01

    OBJECTIVES: To assess in a large population of patients with clinically isolated syndrome (CIS) the relevance of brain lesion location and frequency in predicting 1-year conversion to multiple sclerosis (MS). METHODS: In this multicenter, retrospective study, clinical and MRI data at onset......: In CIS patients with hemispheric, multifocal, and brainstem/cerebellar onset, lesion probability map clusters were seen in clinically eloquent brain regions. Significant lesion clusters were not found in CIS patients with optic nerve and spinal cord onset. At 1 year, clinically definite MS developed...... in the converting group in projection, association, and commissural WM tracts, with larger clusters being in the corpus callosum, corona radiata, and cingulum. CONCLUSIONS: Higher frequency of lesion occurrence in clinically eloquent WM tracts can characterize CIS subjects with different types of onset...

  9. Generative adversarial networks for brain lesion detection

    Science.gov (United States)

    Alex, Varghese; Safwan, K. P. Mohammed; Chennamsetty, Sai Saketh; Krishnamurthi, Ganapathy

    2017-02-01

    Manual segmentation of brain lesions from Magnetic Resonance Images (MRI) is cumbersome and introduces errors due to inter-rater variability. This paper introduces a semi-supervised technique for detection of brain lesion from MRI using Generative Adversarial Networks (GANs). GANs comprises of a Generator network and a Discriminator network which are trained simultaneously with the objective of one bettering the other. The networks were trained using non lesion patches (n=13,000) from 4 different MR sequences. The network was trained on BraTS dataset and patches were extracted from regions excluding tumor region. The Generator network generates data by modeling the underlying probability distribution of the training data, (PData). The Discriminator learns the posterior probability P (Label Data) by classifying training data and generated data as "Real" or "Fake" respectively. The Generator upon learning the joint distribution, produces images/patches such that the performance of the Discriminator on them are random, i.e. P (Label Data = GeneratedData) = 0.5. During testing, the Discriminator assigns posterior probability values close to 0.5 for patches from non lesion regions, while patches centered on lesion arise from a different distribution (PLesion) and hence are assigned lower posterior probability value by the Discriminator. On the test set (n=14), the proposed technique achieves whole tumor dice score of 0.69, sensitivity of 91% and specificity of 59%. Additionally the generator network was capable of generating non lesion patches from various MR sequences.

  10. Comparative brain stem lesions on MRI of acute disseminated encephalomyelitis, neuromyelitis optica, and multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Zhengqi Lu

    Full Text Available BACKGROUND: Brain stem lesions are common in patients with acute disseminated encephalomyelitis (ADEM, neuromyelitis optica (NMO, and multiple sclerosis (MS. OBJECTIVES: To investigate comparative brain stem lesions on magnetic resonance imaging (MRI among adult patients with ADEM, NMO, and MS. METHODS: Sixty-five adult patients with ADEM (n = 17, NMO (n = 23, and MS (n = 25 who had brain stem lesions on MRI were enrolled. Morphological features of brain stem lesions among these diseases were assessed. RESULTS: Patients with ADEM had a higher frequency of midbrain lesions than did patients with NMO (94.1% vs. 17.4%, P<0.001 and MS (94.1% vs. 40.0%, P<0.001; patients with NMO had a lower frequency of pons lesions than did patients with MS (34.8% vs. 84.0%, P<0.001 and ADEM (34.8% vs. 70.6%, P = 0.025; and patients with NMO had a higher frequency of medulla oblongata lesions than did patients with ADEM (91.3% vs. 35.3%, P<0.001 and MS (91.3% vs. 36.0%, P<0.001. On the axial section of the brain stem, the majority (82.4% of patients with ADEM showed lesions on the ventral part; the brain stem lesions in patients with NMO were typically located in the dorsal part (91.3%; and lesions in patients with MS were found in both the ventral (44.0% and dorsal (56.0% parts. The lesions in patients with ADEM (100% and NMO (91.3% had poorly defined margins, while lesions of patients with MS (76.0% had well defined margins. Brain stem lesions in patients with ADEM were usually bilateral and symmetrical (82.4%, while lesions in patients with NMO (87.0% and MS (92.0% were asymmetrical or unilateral. CONCLUSIONS: Brain stem lesions showed various morphological features among adult patients with ADEM, NMO, and MS. The different lesion locations may be helpful in distinguishing these diseases.

  11. Detection of Helicobacter pylori in Oral Lesions

    Directory of Open Access Journals (Sweden)

    Soussan Irani

    2013-12-01

    Full Text Available Background and aims. Helicobacter pylori is a microaerophilic gram-negative spiral organism. It is recognized as the etiologic factor for peptic ulcers, gastric adenocarcinoma and gastric lymphoma. Recently, it has been isolated from dental plaque and the dorsum of the tongue. This study was designed to assess the association between H. pylori and oral lesions such as ulcerative/inflammatory lesions, squamous cell carcinoma (SCC and primary lymphoma. Materials and methods. A total of 228 biopsies diagnosed as oral ulcerative/inflammatory lesions, oral squamous cell carcinoma (OSCC and oral primary lymphoma were selected from the archives of the Pathology Department. Thirty-two samples that were diagnosed as being without any pathological changes were selected as the control group. All the paraffin blocks were cut for hematoxylin and eosin staining to confirm the diagnoses and then the samples were prepared for immunohistochemistry staining. Data were collected and analyzed. Results. Chi-squared test showed significant differences between the frequency of H. pylori positivity in normal tissue and the lesions were examined (P=0.000. In addition, there was a statistically significant difference between the lesions examined (P=0.042. Chi-squared test showed significant differences between H. pylori positivity and different tissue types except inside the muscle layer as follows: in epithelium and in lamina propria (P=0.000, inside the blood vessels (P=0.003, inside the salivary gland duct (P=0.036, and muscle layer (P=0.122. Conclusion. There might be a relation between the presence of H. pylori and oral lesions. Therefore, early detection and eradication of H. pylori in high-risk patients are suggested.

  12. Presence of a central vein within white matter lesions on susceptibility weighted imaging: a specific finding for multiple sclerosis?

    International Nuclear Information System (INIS)

    Lummel, Nina; Boeckh-Behrens, Tobias; Brueckmann, Hartmut; Linn, Jennifer; Schoepf, Veronika; Burke, Michael

    2011-01-01

    Susceptibility weighted imaging depicts the perivenous extent of multiple sclerosis white matter lesions (MS-WML) in vivo by directly visualizing their centrally running vein. The aim of this study was to investigate the specificity of this finding for MS. Fifteen patients with MS and 15 patients with microangiopathic white matter lesions (mWML) underwent 3T MRI, including a fluid-attenuated inversion recovery sequence (FLAIR) and a susceptibility weighted angiography (SWAN). All WMLs were identified on FLAIR and assigned to one of the following localizations: supratentorial peripheral, supratentorial periventricular, or infratentorial. Subsequently, the presence of a central vein within these lesions was assessed on SWAN. A total of 711 MS-WMLs and 1,119 m-WMLs were identified on FLAIR, all of which could also be visualized on SWAN. A central vein was detectable in 80% of the MS-WMLs and in 78% of the m-WMLs (in 73% and 76% of the peripheral, in 92% and 94% of the periventricular, and in 71% and 75% of the infratentorial MS-WMLs and m-WMLs, respectively). With regard to the supratentorial peripheral lesions, significantly more m-WMLs showed a central vein compared to the MS-WMLs. For the other localizations, there was no significant difference between the groups with regard to the percentage of lesions with central vein. Our results indicate that the detection of a central vein within a WML should not be considered a specific finding for MS; it is also found in WMLs of other etiologies. (orig.)

  13. Presence of a central vein within white matter lesions on susceptibility weighted imaging: a specific finding for multiple sclerosis?

    Energy Technology Data Exchange (ETDEWEB)

    Lummel, Nina; Boeckh-Behrens, Tobias; Brueckmann, Hartmut; Linn, Jennifer [University of Munich, Department of Neuroradiology, Munich (Germany); Schoepf, Veronika [University of Munich, Department of Neuroradiology, Munich (Germany); Medical University of Vienna, MR Centre of Excellence, Vienna (Austria); Burke, Michael [GE Healthcare, Solingen (Germany)

    2011-05-15

    Susceptibility weighted imaging depicts the perivenous extent of multiple sclerosis white matter lesions (MS-WML) in vivo by directly visualizing their centrally running vein. The aim of this study was to investigate the specificity of this finding for MS. Fifteen patients with MS and 15 patients with microangiopathic white matter lesions (mWML) underwent 3T MRI, including a fluid-attenuated inversion recovery sequence (FLAIR) and a susceptibility weighted angiography (SWAN). All WMLs were identified on FLAIR and assigned to one of the following localizations: supratentorial peripheral, supratentorial periventricular, or infratentorial. Subsequently, the presence of a central vein within these lesions was assessed on SWAN. A total of 711 MS-WMLs and 1,119 m-WMLs were identified on FLAIR, all of which could also be visualized on SWAN. A central vein was detectable in 80% of the MS-WMLs and in 78% of the m-WMLs (in 73% and 76% of the peripheral, in 92% and 94% of the periventricular, and in 71% and 75% of the infratentorial MS-WMLs and m-WMLs, respectively). With regard to the supratentorial peripheral lesions, significantly more m-WMLs showed a central vein compared to the MS-WMLs. For the other localizations, there was no significant difference between the groups with regard to the percentage of lesions with central vein. Our results indicate that the detection of a central vein within a WML should not be considered a specific finding for MS; it is also found in WMLs of other etiologies. (orig.)

  14. [Case of suspected multiple sclerosis with transcallosal lesions involving the upper surface of the corpus callosum].

    Science.gov (United States)

    Shirafuji, Toshihiko; Oya, Yasushi; Nakamura, Harumasa; Ogata, Katsuhisa; Ogawa, Masafumi; Kawai, Mitsuru

    2008-05-01

    A 26-year-old woman noticed gradually progressive, right lower leg weakness over a 1.5-month period. Neurological examination revealed right hemiparesis with slightly increased deep tendon reflexes, Babinski's sign on the right side, loss of position sense in the right leg, and slight loss of superficial sensation in the right toes. MR FLAIR images showed a high intensity area measuring 5 x 2 x 3 cm in the left frontal lobe, extending to the outer surface of the body of the corpus callosum and the adjacent right cingulate gyrus. Gadolinium enhancement was seen along the cortex and the outer surface of the body of the corpus callosum. CSF findings showed no pleocytosis, a protein content of 32 mg/dl, a sugar level of 85 mg/dl, and an IgG index of 0.46. The biopsy specimen obtained from the superior frontal gyrus showed perivascular cuffing of T-lymphocytes and some B-lymphocytes, as well as multiple small foci of demyelination. Starting on the second day of admission, the patient was treated with methylprednisolone pulse therapy (1,000 mg/day for 3 days); she was then switched to oral prednisolone (20 mg/day). Thereafter, the patient had two clinical relapses: one was due to a lesion in the dorsal part of the medulla oblongata associated with a disturbance of deep sensation in both hands, and the other was due to a lesion involving the right internal capsule, the globus pallidus, and the caudate nucleus associated with left facial nerve palsy. Visual evoked potentials suggested a demyelinating lesion in the right optic nerve. We suspected a diagnosis of multiple sclerosis based on the presence of more than two clinical episodes of neurological deficits with identifiable lesions on MRI. Multiple sclerosis should be considered in the differential diagnosis of lesions located in the outer part of the corpus callosum and transcallosal bilateral hemispheres on MRI, even though inner callosal lesions are common in multiple sclerosis.

  15. Multiple sclerosis

    International Nuclear Information System (INIS)

    Sadashima, Hiromichi; Kusaka, Hirofumi; Imai, Terukuni; Takahashi, Ryosuke; Matsumoto, Sadayuki; Yamamoto, Toru; Yamasaki, Masahiro; Maya, Kiyomi

    1986-01-01

    Eleven patients with a definite diagnosis of multiple sclerosis were examined in terms of correlations between the clinical features and the results of cranial computed tomography (CT), and magnetic resonance imaging (MRI). Results: In 5 of the 11 patients, both CT and MRI demonstrated lesions consistent with a finding of multiple sclerosis. In 3 patients, only MRI demonstrated lesions. In the remaining 3 patients, neither CT nor MRI revealed any lesion in the brain. All 5 patients who showed abnormal findings on both CT and MRI had clinical signs either of cerebral or brainstem - cerebellar lesions. On the other hand, two of the 3 patients with normal CT and MRI findings had optic-nerve and spinal-cord signs. Therefore, our results suggested relatively good correlations between the clinical features, CT, and MRI. MRI revealed cerebral lesions in two of the four patients with clinical signs of only optic-nerve and spinal-cord lesions. MRI demonstrated sclerotic lesions in 3 of the 6 patients whose plaques were not detected by CT. In conclusion, MRI proved to be more helpful in the demonstration of lesions attributable to chronic multiple sclerosis. (author)

  16. Atuoradiographic detection of multiple sclerosis plaques with an ω3 (peripheral type benzodiazepine) binding site radiogland

    International Nuclear Information System (INIS)

    HAUW, J.J.; Sazdovitch, V.; Cornu, P.; Dubois, A.; Benavides, J.; Mac Kenzie, E.; Scatton, B.

    1989-01-01

    In Multiple Sclerosis (MS), the presence of monocyte-macrophages and microglial cells in active plaques is a constant feature. They are numerous at the border of active lesions where they constiture, with other cell types such as lymphocytes and oligodendrocytes the so-called flial wall. Monocyte-macrophages and microglial cells are thought to be directly involved in the process of demyelination. Some macrophages laden with meylin degradation products are also seen in the center of the plaqie, often located in the perivascular cuffs. In addition, astrocytic gliosis occurs in the center of the plaques. As all these cell types are richly endowed with ω3 sites, the feasibility of using ω3 site autoradiagraphy to detect the demyelination plaques in the brain of post-mortem cases of Multiple Sclerosis has been investigated. (Author). 8 refs

  17. Serial changes of magnetic resonance imaging of spinal cord lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Sugimura, Kimiya; Sekimoto, Yoichi; Koike, Yasuo; Takahashi, Akira

    1987-01-01

    Serial changes of magnetic resonance imaging (MRI) of spinal cord lesions in multiple sclerosis (MS) were demonstrated. Two inpatients of MS were followed-up for 8 and 5 months respectively. The first case was a 38-year-old housewife with lesions in upper cervical cord, medulla oblongata and visual nerve. The second case was a 45-year-old man with middle thracic spinal cord and brain stem lesions. Both cases were successfully induced into the remission by peroral prednisolone therapy. In the first case, in early stage of the disease, low signal (in IR method) and high signal (in T 2 -weighted SE method) intensities with enlarged lower dorsal medulla were demonstrated. The second MRI in this case specially in horizontal sections revealed round high intensity lesions (in T 2 -weighted SE) with clear margins, which appeared to push away the normal spinal cord tissue. In the third MRI, T 2 weighted SE revealed localized narrowing in C 2 and C 3 cervical cord, and even no signal lesions in IR method were shown in the central of the spinal cord. The forth and fifth MRI, however, showed almost normally recovered spinal cord and medulla oblongata. In the second case, the first MRI revealed high intensity lesions in the middle thracic spinal cord in T 2 weight SE, and moreover, the spinal cord looked very enlarged. In IR method, localized patchy low intensity lesions were seen in the enlarged spinal cord, but in this case, the MRI demonstrated that localized patchy high intensity lesions without cord swelling in SE remained long after the clinically complete recovery of the disease. (author)

  18. Relevance of brain lesion location to cognition in relapsing multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Francesca Rossi

    Full Text Available OBJECTIVE: To assess the relationship between cognition and brain white matter (WM lesion distribution and frequency in patients with relapsing-remitting multiple sclerosis (RR MS. METHODS: MRI-based T2 lesion probability map (LPM was used to assess the relevance of brain lesion location for cognitive impairment in a group of 142 consecutive patients with RRMS. Significance of voxelwise analyses was p<0.05, cluster-corrected for multiple comparisons. The Rao Brief Repeatable Battery was administered at the time of brain MRI to categorize the MS population into cognitively preserved (CP and cognitively impaired (CI. RESULTS: Out of 142 RRMS, 106 were classified as CP and 36 as CI. Although the CI group had greater WM lesion volume than the CP group (p = 0.001, T2 lesions tended to be less widespread across the WM. The peak of lesion frequency was almost twice higher in CI (61% in the forceps major than in CP patients (37% in the posterior corona radiata. The voxelwise analysis confirmed that lesion frequency was higher in CI than in CP patients with significant bilateral clusters in the forceps major and in the splenium of the corpus callosum (p<0.05, corrected. Low scores of the Symbol Digit Modalities Test correlated with higher lesion frequency in these WM regions. CONCLUSIONS: Overall these results suggest that in MS patients, areas relevant for cognition lie mostly in the commissural fiber tracts. This supports the notion of a functional (multiple disconnection between grey matter structures, secondary to damage located in specific WM areas, as one of the most important mechanisms leading to cognitive impairment in MS.

  19. Acute abdominal pain as the only symptom of a thoracic demyelinating lesion in multiple sclerosis.

    Science.gov (United States)

    Nomura, Shohei; Shimakawa, Shuichi; Kashiwagi, Mitsuru; Tanabe, Takuya; Fukui, Miho; Tamai, Hiroshi

    2015-11-01

    Multiple sclerosis (MS) is a syndrome characterized by complex neurological symptoms resulting from demyelinating lesions in the central nervous system. We report a child with a relapse of MS whose only presenting symptom was severe abdominal pain. Dysfunctional intestinal mobility was assessed by abdominal computed tomography. Findings resembled paralytic ileus resulting from peritonitis. However, the patient demonstrated no other symptoms of peritonitis. A T2-weighted magnetic resonance image revealed a new demyelinating lesion localized to thoracic segments T4-T12. The lesion presumably affected autonomic efferents involved in intestinal mobility. Treatment with a pulse of methylprednisolone reduced both abdominal pain and lesion size. To our knowledge, this is the first reported case of a pediatric MS patient with a demyelinating lesion associated with an autonomic symptom of altered intestinal mobility in the absence of neurological symptoms. This atypical presentation of MS highlights the need for physicians' vigilance when treating this patient population. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  20. FLAIR* to visualize veins in white matter lesions: A new tool for the diagnosis of multiple sclerosis?

    International Nuclear Information System (INIS)

    Campion, T.; Turner, B.P.; Schmierer, K.; Smith, R.J.P.; Altmann, D.R.; Brito, G.C.; Evanson, J.; George, I.C.; Sati, P.; Reich, D.S.; Miquel, M.E.

    2017-01-01

    To explore the potential of a post-processing technique combining FLAIR and T_2* (FLAIR*) to distinguish between lesions caused by multiple sclerosis (MS) from cerebral small vessel disease (SVD) in a clinical setting. FLAIR and T_2* head datasets acquired at 3T of 25 people with relapsing MS (pwRMS) and ten with pwSVD were used. After post-processing, FLAIR* maps were used to determine the proportion of white matter lesions (WML) showing the 'vein in lesion' sign (VIL), a characteristic histopathological feature of MS plaques. Sensitivity and specificity of MS diagnosis were examined on the basis of >45% VIL"+ and >60% VIL"+ WML, and compared with current dissemination in space (DIS) MRI criteria. All pwRMS had >45% VIL"+ WML (range 58-100%) whilst in pwSVD the proportion of VIL"+ WML was significantly lower (0-64%; mean 32±20%). Sensitivity based on >45% VIL"+ was 100% and specificity 80% whilst with >60% VIL"+ as the criterion, sensitivity was 96% and specificity 90%. DIS criteria had 96% sensitivity and 40% specificity. FLAIR* enables VIL"+ WML detection in a clinical setting, facilitating differentiation of MS from SVD based on brain MRI. (orig.)

  1. Lesions inflammatory activity quantification in multiple sclerosis using ["1"1C]-(R)-PK11195 PET brain images

    International Nuclear Information System (INIS)

    Schuck, Phelipi N.; Narciso, Lucas D.L.; Dartora, Caroline M.; Silva, Ana M. Marques da

    2016-01-01

    The criteria for multiple sclerosis (MS) diagnosis include the presence of lesions in brain regions called black holes (BH), characterized by low signal on magnetic resonance imaging T1-weighted. Studies suggest that lesions in MS, if there is an inflammatory process, can be detected in PET imaging with ["1"1C]- (R)-PK11195. The aim of this study is to investigate the uptake of ["1"1C]-(R)-PK11195 in BH in PET images, searching for inflammation activity in lesions and neighborhoods. Semiquantitative methods of SUV and uptake normalization were applied to PET images, in different time intervals, acquired from 8 MS patients and 5 healthy controls. Higher uptake was identified in BH and its edges, when compared with health controls white matter, when the SUV method is applied (p < 0,01, 40 to 60 min). When uptake normalization method is applied, smaller uptake in black holes and its your edges is observed, when compared with white matter apparently healthy (p < 0,01, 0 to 60 min). (author)

  2. FLAIR* to visualize veins in white matter lesions: A new tool for the diagnosis of multiple sclerosis?

    Energy Technology Data Exchange (ETDEWEB)

    Campion, T.; Turner, B.P.; Schmierer, K. [Queen Mary University of London, Blizard Institute (Neuroscience), London (United Kingdom); Barts Health NHS Trust, Emergency Care and Acute Medicine Clinical Academic Group Neuroscience, The Royal London Hospital, London (United Kingdom); Smith, R.J.P. [Queen Mary University of London, Blizard Institute (Neuroscience), London (United Kingdom); Gloucestershire Hospitals NHS Trust, Cheltenham (United Kingdom); Altmann, D.R. [London School of Hygiene and Tropical Medicine, Department of Medical Statistics, London (United Kingdom); Brito, G.C. [Queen Mary University of London, Blizard Institute (Neuroscience), London (United Kingdom); Evanson, J. [Barts Health NHS Trust, Emergency Care and Acute Medicine Clinical Academic Group Neuroscience, The Royal London Hospital, London (United Kingdom); George, I.C. [NIH, Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke, Bethesda, MD (United States); Yale School of Medicine, Department of Neurology, New Haven, CT (United States); Sati, P.; Reich, D.S. [NIH, Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke, Bethesda, MD (United States); Miquel, M.E. [Barts Health NHS Trust, Emergency Care and Acute Medicine Clinical Academic Group Neuroscience, The Royal London Hospital, London (United Kingdom); Queen Mary University of London, William Harvey Research Institute (Cardiovascular Biomedical Research Unit), London (United Kingdom)

    2017-10-15

    To explore the potential of a post-processing technique combining FLAIR and T{sub 2}* (FLAIR*) to distinguish between lesions caused by multiple sclerosis (MS) from cerebral small vessel disease (SVD) in a clinical setting. FLAIR and T{sub 2}* head datasets acquired at 3T of 25 people with relapsing MS (pwRMS) and ten with pwSVD were used. After post-processing, FLAIR* maps were used to determine the proportion of white matter lesions (WML) showing the 'vein in lesion' sign (VIL), a characteristic histopathological feature of MS plaques. Sensitivity and specificity of MS diagnosis were examined on the basis of >45% VIL{sup +} and >60% VIL{sup +} WML, and compared with current dissemination in space (DIS) MRI criteria. All pwRMS had >45% VIL{sup +} WML (range 58-100%) whilst in pwSVD the proportion of VIL{sup +} WML was significantly lower (0-64%; mean 32±20%). Sensitivity based on >45% VIL{sup +} was 100% and specificity 80% whilst with >60% VIL{sup +} as the criterion, sensitivity was 96% and specificity 90%. DIS criteria had 96% sensitivity and 40% specificity. FLAIR* enables VIL{sup +} WML detection in a clinical setting, facilitating differentiation of MS from SVD based on brain MRI. (orig.)

  3. Patient-specific 3D FLAIR for enhanced visualization of brain white matter lesions in multiple sclerosis.

    Science.gov (United States)

    Gabr, Refaat E; Pednekar, Amol S; Govindarajan, Koushik A; Sun, Xiaojun; Riascos, Roy F; Ramírez, María G; Hasan, Khader M; Lincoln, John A; Nelson, Flavia; Wolinsky, Jerry S; Narayana, Ponnada A

    2017-08-01

    To improve the conspicuity of white matter lesions (WMLs) in multiple sclerosis (MS) using patient-specific optimization of single-slab 3D fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Sixteen MS patients were enrolled in a prospective 3.0T MRI study. FLAIR inversion time and echo time were automatically optimized for each patient during the same scan session based on measurements of the relative proton density and relaxation times of the brain tissues. The optimization criterion was to maximize the contrast between gray matter (GM) and white matter (WM), while suppressing cerebrospinal fluid. This criterion also helps increase the contrast between WMLs and WM. The performance of the patient-specific 3D FLAIR protocol relative to the fixed-parameter protocol was assessed both qualitatively and quantitatively. Patient-specific optimization achieved a statistically significant 41% increase in the GM-WM contrast ratio (P < 0.05) and 32% increase in the WML-WM contrast ratio (P < 0.01) compared with fixed-parameter FLAIR. The increase in WML-WM contrast ratio correlated strongly with echo time (P < 10 -11 ). Two experienced neuroradiologists indicated substantially higher lesion conspicuity on the patient-specific FLAIR images over conventional FLAIR in 3-4 cases (intrarater correlation coefficient ICC = 0.72). In no case was the image quality of patient-specific FLAIR considered inferior to conventional FLAIR by any of the raters (ICC = 0.32). Changes in proton density and relaxation times render fixed-parameter FLAIR suboptimal in terms of lesion contrast. Patient-specific optimization of 3D FLAIR increases lesion conspicuity without scan time penalty, and has potential to enhance the detection of subtle and small lesions in MS. 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:557-564. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Detecting circumscribed lesions with the Hough transform

    Energy Technology Data Exchange (ETDEWEB)

    Groshong, B.R; Kegelmeyer, W.P., Jr

    1996-01-11

    We have designed and implemented a circumscribed lesion detection algorithm, based on the Hough Transform, which will detect zero or more approximately circular structures in a mammogram over a range of radii from a few pixels to nearly the size of the breast. We address the geometrical behavior of peaks in Hough parameter space (x,y,r) for both the true radius of a circular structure in the image (r = r{sub o}), and for the parameter r as it passes through this radius. In addition, we evaluate peaks in Hough parameter space by re-analyzing the underlying mammogram in the vicinity of the circular disk indicated by the peak. Discs suggested by the resulting peaks are accumulated in a feature image, scaled by a measure of their quality. These results are then rectified with respect to image contrast extremes and average value. The result is a feature with a continuously scaled pixel level output which suggests the likelihood that a pixel is located inside a circular structure, irrespective of the radius of the structure and overall mammogram contrast. These features are evaluated fast qualitative and quantitative performance metrics which permit circumscribed lesion detection features to be initially evaluated without a full end-to-end classification experiment.

  5. Neural network approach to radiologic lesion detection

    International Nuclear Information System (INIS)

    Newman, F.D.; Raff, U.; Stroud, D.

    1989-01-01

    An area of artificial intelligence that has gained recent attention is the neural network approach to pattern recognition. The authors explore the use of neural networks in radiologic lesion detection with what is known in the literature as the novelty filter. This filter uses a linear model; images of normal patterns become training vectors and are stored as columns of a matrix. An image of an abnormal pattern is introduced and the abnormality or novelty is extracted. A VAX 750 was used to encode the novelty filter, and two experiments have been examined

  6. Improving automated multiple sclerosis lesion segmentation with a cascaded 3D convolutional neural network approach.

    Science.gov (United States)

    Valverde, Sergi; Cabezas, Mariano; Roura, Eloy; González-Villà, Sandra; Pareto, Deborah; Vilanova, Joan C; Ramió-Torrentà, Lluís; Rovira, Àlex; Oliver, Arnau; Lladó, Xavier

    2017-07-15

    In this paper, we present a novel automated method for White Matter (WM) lesion segmentation of Multiple Sclerosis (MS) patient images. Our approach is based on a cascade of two 3D patch-wise convolutional neural networks (CNN). The first network is trained to be more sensitive revealing possible candidate lesion voxels while the second network is trained to reduce the number of misclassified voxels coming from the first network. This cascaded CNN architecture tends to learn well from a small (n≤35) set of labeled data of the same MRI contrast, which can be very interesting in practice, given the difficulty to obtain manual label annotations and the large amount of available unlabeled Magnetic Resonance Imaging (MRI) data. We evaluate the accuracy of the proposed method on the public MS lesion segmentation challenge MICCAI2008 dataset, comparing it with respect to other state-of-the-art MS lesion segmentation tools. Furthermore, the proposed method is also evaluated on two private MS clinical datasets, where the performance of our method is also compared with different recent public available state-of-the-art MS lesion segmentation methods. At the time of writing this paper, our method is the best ranked approach on the MICCAI2008 challenge, outperforming the rest of 60 participant methods when using all the available input modalities (T1-w, T2-w and FLAIR), while still in the top-rank (3rd position) when using only T1-w and FLAIR modalities. On clinical MS data, our approach exhibits a significant increase in the accuracy segmenting of WM lesions when compared with the rest of evaluated methods, highly correlating (r≥0.97) also with the expected lesion volume. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Simultaneous Whole-Brain Segmentation and White Matter Lesion Detection Using Contrast-Adaptive Probabilistic Models

    DEFF Research Database (Denmark)

    Puonti, Oula; Van Leemput, Koen

    2016-01-01

    In this paper we propose a new generative model for simultaneous brain parcellation and white matter lesion segmentation from multi-contrast magnetic resonance images. The method combines an existing whole-brain segmentation technique with a novel spatial lesion model based on a convolutional...... restricted Boltzmann machine. Unlike current state-of-the-art lesion detection techniques based on discriminative modeling, the proposed method is not tuned to one specific scanner or imaging protocol, and simultaneously segments dozens of neuroanatomical structures. Experiments on a public benchmark dataset...... in multiple sclerosis indicate that the method’s lesion segmentation accuracy compares well to that of the current state-of-the-art in the field, while additionally providing robust whole-brain segmentations....

  8. Brain MRI lesions and atrophy are associated with employment status in patients with multiple sclerosis.

    Science.gov (United States)

    Tauhid, Shahamat; Chu, Renxin; Sasane, Rahul; Glanz, Bonnie I; Neema, Mohit; Miller, Jennifer R; Kim, Gloria; Signorovitch, James E; Healy, Brian C; Chitnis, Tanuja; Weiner, Howard L; Bakshi, Rohit

    2015-11-01

    Multiple sclerosis (MS) commonly affects occupational function. We investigated the link between brain MRI and employment status. Patients with MS (n = 100) completed a Work Productivity and Activity Impairment (WPAI) (general health version) survey measuring employment status, absenteeism, presenteeism, and overall work and daily activity impairment. Patients "working for pay" were considered employed; "temporarily not working but looking for work," "not working or looking for work due to age," and "not working or looking for work due to disability" were considered not employed. Brain MRI T1 hypointense (T1LV) and T2 hyperintense (T2LV) lesion volumes were quantified. To assess lesional destructive capability, we calculated each subject's ratio of T1LV to T2LV (T1/T2). Normalized brain parenchymal volume (BPV) assessed brain atrophy. The mean (SD) age was 45.5 (9.7) years; disease duration was 12.1 (8.1) years; 75 % were women, 76 % were relapsing-remitting, and 76 % were employed. T1LV, T1/T2, Expanded Disability Status Scale (EDSS) scores, and activity impairment were lower and BPV was higher in the employed vs. not employed group (Wilcoxon tests, p 0.05). In multivariable logistic regression modeling, adjusting for age, sex, and disease duration, higher T1LV predicted a lower chance of employment (p 0.05). We report a link between brain atrophy and lesions, particularly lesions with destructive potential, to MS employment status.

  9. Appearance of Tissue Transglutaminase in Astrocytes in Multiple Sclerosis Lesions: A Role in Cell Adhesion and Migration?

    NARCIS (Netherlands)

    van Strien, M.; Drukarch, B.; Bol, J.G.J.M.; van der Valk, P.; van Horssen, J.; Gerritsen, W.H.; Breve, J.J.P.; van Dam, A.M.

    2011-01-01

    Multiple Sclerosis (MS) is a neuroinflammatory disease mainly affecting young adults. A major pathological hallmark of MS is the presence of demyelinated lesions in the central nervous system. In the active phase of the disease, astrocytes become activated, migrate and contribute to local tissue

  10. MUSCLE-FIBER CONDUCTION-VELOCITY IN AMYOTROPHIC-LATERAL-SCLEROSIS AND TRAUMATIC LESIONS OF THE PLEXUS BRACHIALIS

    NARCIS (Netherlands)

    VANDERHOEVEN, JH; ZWARTS, MJ; VANWEERDEN, TW

    1993-01-01

    Muscle fiber conduction velocity (MFCV) in biceps brachii was studied in traumatic brachial plexus lesions (16 patients) and amyotrophic lateral sclerosis (ALS) (22 patients) by means of an invasive (S-MFCV) and a surface (S-MFCV) method. After complete denervation an exponential decrease of the

  11. Transcript profiling of different types of multiple sclerosis lesions yields FGF1 as a promoter of remyelination

    NARCIS (Netherlands)

    Mohan, Hema; Friese, Anita; Albrecht, Stefanie; Krumbholz, Markus; Elliott, Christina L; Arthur, Ariel; Menon, Ramesh; Farina, Cinthia; Junker, Andreas; Stadelmann, Christine; Barnett, Susan C; Huitinga, I.; Wekerle, Hartmut; Hohlfeld, Reinhard; Lassmann, Hans; Kuhlmann, Tanja; Linington, Chris; Meinl, Edgar

    2014-01-01

    Chronic demyelination is a pathological hallmark of multiple sclerosis (MS). Only a minority of MS lesions remyelinates completely. Enhancing remyelination is, therefore, a major aim of future MS therapies. Here we took a novel approach to identify factors that may inhibit or support endogenous

  12. MR spectroscopy (MRS) and magnetisation transfer imaging (MTI), lesion load and clinical scores in early relapsing remitting multiple sclerosis: a combined cross-sectional and longitudinal study

    Energy Technology Data Exchange (ETDEWEB)

    Bellmann-Strobl, J.; Paul, F.; Aktas, O.; Zipp, F. [Charite - University Medicine Berlin and Max Delbrueck Center for Molecular Medicine, Cecilie Vogt Clinic for Neurology, Berlin (Germany); Stiepani, H.; Bohner, G.; Klingebiel, R. [Charite - University Medicine Berlin, Department of Neuroradiology, Berlin (Germany); Wuerfel, J. [Charite - University Medicine Berlin and Max Delbrueck Center for Molecular Medicine, Cecilie Vogt Clinic for Neurology, Berlin (Germany); University Schleswig-Holstein, Institute of Neuroradiology, Campus Luebeck, Kiel (Germany); Warmuth, C. [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Wandinger, K.P. [Charite - University Medicine Berlin, Department of Neurology, Berlin (Germany)

    2009-08-15

    The purpose of this study was to correlate magnetic resonance imaging (MRI)-based lesion load assessment with clinical disability in early relapsing remitting multiple sclerosis (RRMS). Seventeen untreated patients (ten women, seven men; mean age 33.0{+-}7.9 years) with the initial diagnosis of RRMS were included for cross-sectional as well as longitudinal (24 months) clinical and MRI-based assessment in comparison with age-matched healthy controls. Conventional MR sequences, MR spectroscopy (MRS) and magnetisation transfer imaging (MTI) were performed at 1.5 T. Lesion number and volume, MRS and MTI measurements for lesions and normal appearing white matter (NAWM) were correlated to clinical scores [Expanded Disability Status Scale (EDSS), Multiple Sclerosis Functional Composite (MSFC)] for monitoring disease course after treatment initiation (interferon {beta}-1a). MTI and MRS detected changes [magnetisation transfer ratio (MTR), N-acetylaspartate (NAA)/creatine ratio] in NAWM over time. EDSS and lesional MTR increases correlated throughout the disease course. Average MTR of NAWM raised during the study (p<0.05) and correlated to the MSFC score (r=0.476, p<0.001). At study termination, NAA/creatine ratio of NAWM correlated to the MSFC score (p<0.05). MTI and MRS were useful for initial disease assessment in NAWM. MTI and MRS correlated with clinical scores, indicating potential for monitoring the disease course and gaining new insights into treatment-related effects. (orig.)

  13. MR spectroscopy (MRS) and magnetisation transfer imaging (MTI), lesion load and clinical scores in early relapsing remitting multiple sclerosis: a combined cross-sectional and longitudinal study

    International Nuclear Information System (INIS)

    Bellmann-Strobl, J.; Paul, F.; Aktas, O.; Zipp, F.; Stiepani, H.; Bohner, G.; Klingebiel, R.; Wuerfel, J.; Warmuth, C.; Wandinger, K.P.

    2009-01-01

    The purpose of this study was to correlate magnetic resonance imaging (MRI)-based lesion load assessment with clinical disability in early relapsing remitting multiple sclerosis (RRMS). Seventeen untreated patients (ten women, seven men; mean age 33.0±7.9 years) with the initial diagnosis of RRMS were included for cross-sectional as well as longitudinal (24 months) clinical and MRI-based assessment in comparison with age-matched healthy controls. Conventional MR sequences, MR spectroscopy (MRS) and magnetisation transfer imaging (MTI) were performed at 1.5 T. Lesion number and volume, MRS and MTI measurements for lesions and normal appearing white matter (NAWM) were correlated to clinical scores [Expanded Disability Status Scale (EDSS), Multiple Sclerosis Functional Composite (MSFC)] for monitoring disease course after treatment initiation (interferon β-1a). MTI and MRS detected changes [magnetisation transfer ratio (MTR), N-acetylaspartate (NAA)/creatine ratio] in NAWM over time. EDSS and lesional MTR increases correlated throughout the disease course. Average MTR of NAWM raised during the study (p<0.05) and correlated to the MSFC score (r=0.476, p<0.001). At study termination, NAA/creatine ratio of NAWM correlated to the MSFC score (p<0.05). MTI and MRS were useful for initial disease assessment in NAWM. MTI and MRS correlated with clinical scores, indicating potential for monitoring the disease course and gaining new insights into treatment-related effects. (orig.)

  14. Quantitative assessment of multiple sclerosis lesion load using CAD and expert input

    Science.gov (United States)

    Gertych, Arkadiusz; Wong, Alexis; Sangnil, Alan; Liu, Brent J.

    2008-03-01

    Multiple sclerosis (MS) is a frequently encountered neurological disease with a progressive but variable course affecting the central nervous system. Outline-based lesion quantification in the assessment of lesion load (LL) performed on magnetic resonance (MR) images is clinically useful and provides information about the development and change reflecting overall disease burden. Methods of LL assessment that rely on human input are tedious, have higher intra- and inter-observer variability and are more time-consuming than computerized automatic (CAD) techniques. At present it seems that methods based on human lesion identification preceded by non-interactive outlining by CAD are the best LL quantification strategies. We have developed a CAD that automatically quantifies MS lesions, displays 3-D lesion map and appends radiological findings to original images according to current DICOM standard. CAD is also capable to display and track changes and make comparison between patient's separate MRI studies to determine disease progression. The findings are exported to a separate imaging tool for review and final approval by expert. Capturing and standardized archiving of manual contours is also implemented. Similarity coefficients calculated from quantities of LL in collected exams show a good correlation of CAD-derived results vs. those incorporated as expert's reading. Combining the CAD approach with an expert interaction may impact to the diagnostic work-up of MS patients because of improved reproducibility in LL assessment and reduced time for single MR or comparative exams reading. Inclusion of CAD-generated outlines as DICOM-compliant overlays into the image data can serve as a better reference in MS progression tracking.

  15. Early detection of multiple sclerosis: MR findings during the initial manifestations of multiple sclerosis

    International Nuclear Information System (INIS)

    Schoerner, W.; Baum, K.; Henkes, H.; Girke, W.; Felix, R.; Klinikum Rudolf Virchow, Berlin

    1988-01-01

    The MR results in 21 patients showing the initial manifestations of multiple sclerosis (MS) were compared with those in 45 patients with a long history of MS. As in the old cases, MR proved a very sensitive technique during the early manifestations, with abnormal findings in 20 out of 21 patients. The relatively characteristic MR findings in long-standing MS (predominant peri-ventricular involvement with a relatively typical pattern) was seen in the early stages is only rare cases. The value of MR during the initial manifestations of MS is in cases where the clinical findings are not conclusive and laboratory diagnosis (evoked potentials, CSF findings) are indefinite. In these patients the finding of multiple lesions in the brain can confirm the suspected diagnosis of MS. (orig.) [de

  16. Evaluating the effect of multiple sclerosis lesions on automatic brain structure segmentation

    Directory of Open Access Journals (Sweden)

    Sandra González-Villà

    2017-01-01

    Full Text Available In recent years, many automatic brain structure segmentation methods have been proposed. However, these methods are commonly tested with non-lesioned brains and the effect of lesions on their performance has not been evaluated. Here, we analyze the effect of multiple sclerosis (MS lesions on three well-known automatic brain structure segmentation methods, namely, FreeSurfer, FIRST and multi-atlas fused by majority voting, which use learning-based, deformable and atlas-based strategies, respectively. To perform a quantitative analysis, 100 synthetic images of MS patients with a total of 2174 lesions are simulated on two public databases with available brain structure ground truth information (IBSR18 and MICCAI’12. The Dice similarity coefficient (DSC differences and the volume differences between the healthy and the simulated images are calculated for the subcortical structures and the brainstem. We observe that the three strategies are affected when lesions are present. However, the effects of the lesions do not follow the same pattern; the lesions either make the segmentation method underperform or surprisingly augment the segmentation accuracy. The obtained results show that FreeSurfer is the method most affected by the presence of lesions, with DSC differences (generated − healthy ranging from −0.11 ± 0.54 to 9.65 ± 9.87, whereas FIRST tends to be the most robust method when lesions are present (−2.40 ± 5.54 to 0.44 ± 0.94. Lesion location is not important for global strategies such as FreeSurfer or majority voting, where structure segmentation is affected wherever the lesions exist. On the other hand, FIRST is more affected when the lesions are overlaid or close to the structure of analysis. The most affected structure by the presence of lesions is the nucleus accumbens (from −1.12 ± 2.53 to 1.32 ± 4.00 for the left hemisphere and from −2.40 ± 5.54 to 9.65 ± 9.87 for the right hemisphere, whereas the

  17. Complement is activated in progressive multiple sclerosis cortical grey matter lesions.

    Science.gov (United States)

    Watkins, Lewis M; Neal, James W; Loveless, Sam; Michailidou, Iliana; Ramaglia, Valeria; Rees, Mark I; Reynolds, Richard; Robertson, Neil P; Morgan, B Paul; Howell, Owain W

    2016-06-22

    The symptoms of multiple sclerosis (MS) are caused by damage to myelin and nerve cells in the brain and spinal cord. Inflammation is tightly linked with neurodegeneration, and it is the accumulation of neurodegeneration that underlies increasing neurological disability in progressive MS. Determining pathological mechanisms at play in MS grey matter is therefore a key to our understanding of disease progression. We analysed complement expression and activation by immunocytochemistry and in situ hybridisation in frozen or formalin-fixed paraffin-embedded post-mortem tissue blocks from 22 progressive MS cases and made comparisons to inflammatory central nervous system disease and non-neurological disease controls. Expression of the transcript for C1qA was noted in neurons and the activation fragment and opsonin C3b-labelled neurons and glia in the MS cortical and deep grey matter. The density of immunostained cells positive for the classical complement pathway protein C1q and the alternative complement pathway activation fragment Bb was significantly increased in cortical grey matter lesions in comparison to control grey matter. The number of cells immunostained for the membrane attack complex was elevated in cortical lesions, indicating complement activation to completion. The numbers of classical (C1-inhibitor) and alternative (factor H) pathway regulator-positive cells were unchanged between MS and controls, whilst complement anaphylatoxin receptor-bearing microglia in the MS cortex were found closely apposed to cortical neurons. Complement immunopositive neurons displayed an altered nuclear morphology, indicative of cell stress/damage, supporting our finding of significant neurodegeneration in cortical grey matter lesions. Complement is activated in the MS cortical grey matter lesions in areas of elevated numbers of complement receptor-positive microglia and suggests that complement over-activation may contribute to the worsening pathology that underlies the

  18. Recommendations to improve imaging and analysis of brain lesion load and atrophy in longitudinal studies of multiple sclerosis

    DEFF Research Database (Denmark)

    Vrenken, H; Jenkinson, M; Horsfield, M A

    2013-01-01

    resonance image analysis methods for assessing brain lesion load and atrophy, this paper makes recommendations to improve these measures for longitudinal studies of MS. Briefly, they are (1) images should be acquired using 3D pulse sequences, with near-isotropic spatial resolution and multiple image......Focal lesions and brain atrophy are the most extensively studied aspects of multiple sclerosis (MS), but the image acquisition and analysis techniques used can be further improved, especially those for studying within-patient changes of lesion load and atrophy longitudinally. Improved accuracy...

  19. Topological characteristics of brainstem lesions in clinically definite and clinically probable cases of multiple sclerosis: An MRI-study

    International Nuclear Information System (INIS)

    Brainin, M.; Omasits, M.; Reisner, T.; Neuhold, A.; Wicke, L.

    1987-01-01

    Disseminated lesions in the white matter of the cerebral hemispheres and confluent lesions at the borders of the lateral ventricles as seen on MRI are both considered acceptable paraclinical evidence for the diagnosis of multiple sclerosis. Similar changes are, however, also found in vascular diseases of the brain. We therefore aimed at identifying those additional traits in the infratentorial region, which in our experience are not frequently found in cerebrovascular pathology. We evaluated MR brain scans of 68 patients and found pontine lesions in 71% of cases with a clinically definite diagnosis (17 out of 24) and in 33% of cases with a probable diagnosis (14 out of 43). Lesions in the medulla oblongata were present in 50% and 16%, respectively, and in the midbrain in 25% and 7%, respectively. With rare exceptions all brainstem lesions were contiguous with the cisternal or ventricular cerebrospinal fluid spaces. In keeping with post-mortem reports the morphological spectrum ranged from large confluent patches to solitary, well delineated paramedian lesions or discrete linings of the cerebrospinal fluid border zones and were most clearly depicted from horizontal and sagittal T2 weighted SE-sequences. If there is a predilection for the outer or inner surfaces of the brainstem, such lesions can be considered an additional typical feature of multiple sclerosis and can be more reliably weighted as paraclinical evidence for a definite diagnosis. (orig.)

  20. Tracking the Evolution of Cerebral Gadolinium-Enhancing Lesions to Persistent T1 Black Holes in Multiple Sclerosis: Validation of a Semiautomated Pipeline.

    Science.gov (United States)

    Andermatt, Simon; Papadopoulou, Athina; Radue, Ernst-Wilhelm; Sprenger, Till; Cattin, Philippe

    2017-09-01

    Some gadolinium-enhancing multiple sclerosis (MS) lesions remain T1-hypointense over months ("persistent black holes, BHs") and represent areas of pronounced tissue loss. A reduced conversion of enhancing lesions to persistent BHs could suggest a favorable effect of a medication on tissue repair. However, the individual tracking of enhancing lesions can be very time-consuming in large clinical trials. We created a semiautomated workflow for tracking the evolution of individual MS lesions, to calculate the proportion of enhancing lesions becoming persistent BHs at follow-up. Our workflow automatically coregisters, compares, and detects overlaps between lesion masks at different time points. We tested the algorithm in a data set of Magnetic Resonance images (1.5 and 3T; spin-echo T1-sequences) from a phase 3 clinical trial (n = 1,272), in which all enhancing lesions and all BHs had been previously segmented at baseline and year 2. The algorithm analyzed the segmentation masks in a longitudinal fashion to determine which enhancing lesions at baseline turned into BHs at year 2. Images of 50 patients (192 enhancing lesions) were also reviewed by an experienced MRI rater, blinded to the algorithm results. In this MRI data set, there were no cases that could not be processed by the algorithm. At year 2, 417 lesions were classified as persistent BHs (417/1,613 = 25.9%). The agreement between the rater and the algorithm was > 98%. Due to the semiautomated procedure, this algorithm can be of great value in the analysis of large clinical trials, when a rater-based analysis would be time-consuming. Copyright © 2017 by the American Society of Neuroimaging.

  1. Incidentally Detected Enhancing Breast Lesions on Chest Computed Tomography

    International Nuclear Information System (INIS)

    Lin, Wen Chiung; Hsu, Hsian He; Yu, Jyh Cherng; Hsu, Giu Cheng; Yu, Cheng Ping; Chang, Tsun Hou; Huang, Guo Shu; Li, Chao Shiang

    2011-01-01

    To evaluate the nature and imaging appearance of incidental enhancing breast lesions detected on a routine contrast-enhanced chest CT. Twenty-three patients with incidental enhancing breast lesions on contrast-enhanced chest CT were retrospectively reviewed. The breast lesions were reviewed by unenhanced and enhanced CT, and evaluated by observing the shapes, margins, enhancement patterns and backgrounds of breast lesions. A histopathologic diagnosis or long-term follow-up served as reference standard. Sixteen (70%) patients had malignant breast lesions and seven (30%) had benign lesions. In 10 patients, the breast lesions were exclusively detected on contrast-enhanced CT. Using unenhanced CT, breast lesions with fi broglandular backgrounds were prone to be obscured (p < 0.001). Incidental primary breast cancer showed an non-significant trend of a higher percentage irregular margin (p = 0.056). All of the four incidental breast lesions with non-mass-like enhancement were proven to be malignant. Routine contrast-enhanced chest CT can reveal sufficient details to allow for the detection of unsuspected breast lesions, in which some cases may be proven as malignant. An irregular margin of incidental enhancing breast lesion can be considered a suggestive sign of malignancy

  2. Detection activity assessment and diagnosis of dental caries lesions

    DEFF Research Database (Denmark)

    Braga, Mariana M; Mendes, Fausto M; Ekstrand, Kim R

    2010-01-01

    This article reviews the current methods for detection and assessment of caries lesions focusing on applicability for daily clinical practice. The end point is to arrive at a diagnosis for each caries lesion. Visual inspection aided by a ball-ended probe is essential for caries lesions assessment...... and the method must be used for all patients. Use of indices, for example, the International Caries Detection and Assessment System (ICDAS), can improve the performance of this method. Using visual inspection, the clinician must decide about the presence, severity and activity of lesions. After this process...

  3. A tumefactive multiple sclerosis lesion in the brain: An uncommon site with atypical magnetic resonance image findings

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Min Sun; Kim, Hyun Sook; Kim, Jae Hoon; Kim, Eun Kyung; Choi, Yun Sun [Eulji Hospital, Eulji University, Seoul (Korea, Republic of)

    2013-11-15

    Tumefactive multiple sclerosis (MS) is a rare type of demyelinating disease. Typical magnetic resonance (MR) image findings show incomplete ring enhancement with a mild mass effect. This lesion is otherwise indistinguishable from other mass-like lesions in the brain. Knowledge of the MR imaging findings for tumefactive MS is thus helpful for correct diagnosis and appropriate therapy. In this report we describe the MR image findings for pathology-confirmed tumefactive MS in an uncommon location, alongside a discussion of its aggressive features.

  4. Cardiovascular risk factors are associated with increased lesion burden and brain atrophy in multiple sclerosis.

    Science.gov (United States)

    Kappus, Natalie; Weinstock-Guttman, Bianca; Hagemeier, Jesper; Kennedy, Cheryl; Melia, Rebecca; Carl, Ellen; Ramasamy, Deepa P; Cherneva, Mariya; Durfee, Jacqueline; Bergsland, Niels; Dwyer, Michael G; Kolb, Channa; Hojnacki, David; Ramanathan, Murali; Zivadinov, Robert

    2016-02-01

    Cardiovascular (CV) risk factors have been associated with changes in clinical outcomes in patients with multiple sclerosis (MS). To investigate the frequency of CV risks in patients with MS and their association with MRI outcomes. In a prospective study, 326 patients with relapsing-remitting MS and 163 patients with progressive MS, 61 patients with clinically isolated syndrome (CIS) and 175 healthy controls (HCs) were screened for CV risks and scanned on a 3T MRI scanner. Examined CV risks included hypertension, heart disease, smoking, overweight/obesity and type 1 diabetes. MRI measures assessed lesion volumes (LVs) and brain atrophy. Association between individual or multiple CV risks and MRI outcomes was examined adjusting for age, sex, race, disease duration and treatment status. Patients with MS showed increased frequency of smoking (51.7% vs 36.5%, p = 0.001) and hypertension (33.9% vs 24.7%, p=0.035) compared with HCs. In total, 49.9% of patients with MS and 36% of HCs showed ≥ 2 CV risks (p = 0.003), while the frequency of ≥ 3 CV risks was 18.8% in the MS group and 8.6% in the HCs group (p = 0.002). In patients with MS, hypertension and heart disease were associated with decreased grey matter (GM) and cortical volumes (p < 0.05), while overweight/obesity was associated with increased T1-LV (p < 0.39) and smoking with decreased whole brain volume (p = 0.049). Increased lateral ventricle volume was associated with heart disease (p = 0.029) in CIS. Patients with MS with one or more CV risks showed increased lesion burden and more advanced brain atrophy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Recent advances in multiple sclerosis therapy

    International Nuclear Information System (INIS)

    Gonsette, R.E.; Delmotte, P.

    1989-01-01

    Seven papers in this volume are in INIS scope, one dealing with autoradiographic detection of multiple sclerosis plaques with radiologands, and the others with magnetic resonance imaging of MS lesions. (H.W.). refs.; figs.; tabs

  6. Optimization of PET system design for lesion detection

    International Nuclear Information System (INIS)

    Qi, Jinyi

    2000-01-01

    Traditionally, the figures of merit used in designing a PET scanner are spatial resolution, noise equivalent count rate, noise equivalent sensitivity, etc. These measures, however, do not directly reflect the lesion detectability using the PET scanner. Here we propose to optimize PET scanner design directly for lesion detection. The signal-to-noise ratio (SNR) of lesion detection can be easily computed using the theoretical expressions that we have previously derived. Because no time consuming Monte Carlo simulation is needed, the theoretical expressions allow evaluation of a large range of parameters. The PET system parameters can then be chosen to achieve the maximum SNR for lesion detection. The simulation study shown in this paper was focused a single ring PET scanner without depth of interaction measurement. Randoms and scatters were also ignored

  7. Lesional-targeting of neuroprotection to the inflammatory penumbra in experimental multiple sclerosis

    NARCIS (Netherlands)

    Al-Izki, S.; Pryce, G.; Hankey, D.J.R.; Lidster, K.; von Kutzleben, S.M.; Browne, L.; Clutterbuck, L.; Posada, C.; Chan, A.W.E.; Amor, S.; Perkins, V.; Gerritsen, W.H.; Ummenthum, K.; Peferoen-Baert, R.; van der Valk, P.; Montoya, A.; Joel, S.P.; Garthwaite, J.; Giovannoni, G.; Selwood, D.L.; Baker, D.

    2014-01-01

    Progressive multiple sclerosis is associated with metabolic failure of the axon and excitotoxicity that leads to chronic neurodegeneration. Global sodium-channel blockade causes side effects that can limit its use for neuroprotection in multiple sclerosis. Through selective targeting of drugs to

  8. Multispectral detection of cutaneous lesions using spectroscopy and microscopy approaches

    Science.gov (United States)

    Borisova, E.; Genova-Hristova, Ts.; Troyanova, P.; Pavlova, E.; Terziev, I.; Semyachkina-Glushkovskaya, O.; Lomova, M.; Genina, E.; Stanciu, G.; Tranca, D.; Avramov, L.

    2018-02-01

    Autofluorescence, diffuse-reflectance and transmission spectral, and microscopic measurements were made on different cutaneous neoplastic lesions, namely basal cell carcinoma, squamous cell carcinoma, malignant melanoma, and dysplastic and benign lesions related. Spectroscopic measurements were made on ex vivo tissue samples, and confocal microscopy investigations were made on thin tissue slices. Fluorescence spectra obtained reveal statistically significant differences between the different benign, dysplastic and malignant lesions by the level of emission intensity, as well by spectral shape, which are fingerprints applicable for differentiation algorithms. In reflectance mode the most significant differences are related to the influence of skin pigments - melanin and hemoglobin. Transmission spectroscopy mode gave complementary optical properties information about the tissue samples investigated to that one of reflectance and absorption spectroscopy. Using autofluorescence detection of skin lesions we obtain very good diagnostic performance for distinguishing of nonmelanoma lesions. Using diffuse reflectance and transmission spectroscopy we obtain significant tool for pigmented pathologies differentiation, but it is a tool with moderate sensitivity for non-melanoma lesions detection. One could rapidly increase the diagnostic accuracy of the received combined "optical biopsy" method when several spectral detection techniques are applied in common algorithm for lesions' differentiation. Specific spectral features observed in each type of lesion investigated on micro and macro level would be presented and discussed. Correlation between the spectral data received and the microscopic features observed would be discussed in the report.

  9. The role of qualitative and quantitative MRI assessment of multiple sclerosis lesions according to their in evaluating the efficacy of intravenous immunoglobulin G

    Energy Technology Data Exchange (ETDEWEB)

    Kocer, B. [Sedat Simavi sokak 17/32 B Blok Cankaya, Sedat Simavi sokak 17/32 B Blok Cankaya, 06550, Ankara (Turkey); Department of Neurology, Gazi University Faculty of Medicine, 06510, Ankara (Turkey); Yildirim-Guerel, S.; Tali, E.T.; Isik, S. [Department of Radiology, Gazi University Faculty of Medicine, 06510, Ankara (Turkey); Irkec, C. [Department of Neurology, Gazi University Faculty of Medicine, 06510, Ankara (Turkey)

    2004-04-01

    We evaluation of the role of determining the distribution of brain-stem, cerebellar and cerebral lesions in number and volume by MRI in determining the efficiency of treatment of multiple sclerosis (MS). We studied 24 patients diagnosed as having relapsing and remitting MS, of whom 12 received intravenous immunoglobulin G; a control group of 12 were given placebo. In a double-blind study, MRI was obtained initially and at 3, 6 and 9 months, and interpreted without knowledge of clinical findings, laboratory tests or treatment. The lesions were classified according to their distribution and evaluated qualitatively and quantitatively. Each patient was also examined clinically and scored according to the expanded disability status scale (EDSS) following every MRI examination. All patients in the treatment group showed significant improvement. The lesions decreased in both in size and number in all sites. In the control group lesions increased both in number and size in all sites, but only the increase between 3and 6 months was statistically significant. In both groups, significant apparent changes were detected in the cerebellum and brain stem. Volumetric evaluation was found to be more helpful than qualitative assessment. (orig.)

  10. The role of qualitative and quantitative MRI assessment of multiple sclerosis lesions according to their in evaluating the efficacy of intravenous immunoglobulin G

    International Nuclear Information System (INIS)

    Kocer, B.; Yildirim-Guerel, S.; Tali, E.T.; Isik, S.; Irkec, C.

    2004-01-01

    We evaluation of the role of determining the distribution of brain-stem, cerebellar and cerebral lesions in number and volume by MRI in determining the efficiency of treatment of multiple sclerosis (MS). We studied 24 patients diagnosed as having relapsing and remitting MS, of whom 12 received intravenous immunoglobulin G; a control group of 12 were given placebo. In a double-blind study, MRI was obtained initially and at 3, 6 and 9 months, and interpreted without knowledge of clinical findings, laboratory tests or treatment. The lesions were classified according to their distribution and evaluated qualitatively and quantitatively. Each patient was also examined clinically and scored according to the expanded disability status scale (EDSS) following every MRI examination. All patients in the treatment group showed significant improvement. The lesions decreased in both in size and number in all sites. In the control group lesions increased both in number and size in all sites, but only the increase between 3and 6 months was statistically significant. In both groups, significant apparent changes were detected in the cerebellum and brain stem. Volumetric evaluation was found to be more helpful than qualitative assessment. (orig.)

  11. Lesion load may predict long-term cognitive dysfunction in multiple sclerosis patients.

    Directory of Open Access Journals (Sweden)

    Francesco Patti

    Full Text Available Magnetic Resonance Imaging (MRI techniques provided evidences into the understanding of cognitive impairment (CIm in Multiple Sclerosis (MS.To investigate the role of white matter (WM and gray matter (GM in predicting long-term CIm in a cohort of MS patients.303 out of 597 patients participating in a previous multicenter clinical-MRI study were enrolled (49.4% were lost at follow-up. The following MRI parameters, expressed as fraction (f of intracranial volume, were evaluated: cerebrospinal fluid (CSF-f, WM-f, GM-f and abnormal WM (AWM-f, a measure of lesion load. Nine years later, cognitive status was assessed in 241 patients using the Symbol Digit Modalities Test (SDMT, the Semantically Related Word List Test (SRWL, the Modified Card Sorting Test (MCST, and the Paced Auditory Serial Addition Test (PASAT. In particular, being SRWL a memory test, both immediate recall and delayed recall were evaluated. MCST scoring was calculated based on the number of categories, number of perseverative and non-perseverative errors.AWM-f was predictive of an impaired performance 9 years ahead in SDMT (OR 1.49, CI 1.12-1.97 p = 0.006, PASAT (OR 1.43, CI 1.14-1.80 p = 0.002, SRWL-immediate recall (OR 1.72 CI 1.35-2.20 p<0.001, SRWL-delayed recall (OR 1.61 CI 1.28-2.03 p<0.001, MCST-category (OR 1.52, CI 1.2-1.9 p<0.001, MCST-perseverative error(OR 1.51 CI 1.2-1.9 p = 0.001, MCST-non perseverative error (OR 1.26 CI 1.02-1.55 p = 0.032.In our large MS cohort, focal WM damage appeared to be the most relevant predictor of the long-term cognitive outcome.

  12. Detection and monitoring of early caries lesions

    DEFF Research Database (Denmark)

    Pretty, I A; Ekstrand, K R

    2016-01-01

    and co-workers from 2013 and this still represents the current state of the science in relation to caries detection and monitoring. The review described among others, visible detection systems, image-based detection systems and point-measurement approaches. RESULTS: The current evidence base suggests...... that while there are numerous devices or technology-enabled detection systems, the use of a careful, methodical visual inspection of clean, dry teeth, supplemented where indicated by radiographic views, remains the standard of care in caries detection and diagnostics. Further, it is possible by means...... to the clinician and the patient for whom it may be a useful educational and motivational tool. CONCLUSIONS: Recommendations are presented that can be adopted and adapted to local circumstances and that are both substantiated by evidence and promote a clear, simple and consistent approach to caries detection...

  13. Automated detection of fundus photographic red lesions in diabetic retinopathy.

    Science.gov (United States)

    Larsen, Michael; Godt, Jannik; Larsen, Nicolai; Lund-Andersen, Henrik; Sjølie, Anne Katrin; Agardh, Elisabet; Kalm, Helle; Grunkin, Michael; Owens, David R

    2003-02-01

    To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard reference was defined by classifying each patient as having or not having diabetic retinopathy based on overall visual grading of the digitized transparencies. A single-lesion visual grading was made independently, comprising meticulous outlining of all single lesions in all photographs and used to develop the automated red lesion detection system. A comparison of visual and automated single-lesion detection in replicating the overall visual grading was then performed. Automated red lesion detection demonstrated a specificity of 71.4% and a resulting sensitivity of 96.7% in detecting diabetic retinopathy when applied at a tentative threshold setting for use in diabetic retinopathy screening. The accuracy of 79% could be raised to 85% by adjustment of a single user-supplied parameter determining the balance between the screening priorities, for which a considerable range of options was demonstrated by the receiver-operating characteristic (area under the curve 90.3%). The agreement of automated lesion detection with overall visual grading (0.659) was comparable to the mean agreement of six ophthalmologists (0.648). Detection of diabetic retinopathy by automated detection of single fundus lesions can be achieved with a performance comparable to that of experienced ophthalmologists. The results warrant further investigation of automated fundus image analysis as a tool for diabetic retinopathy screening.

  14. Lesion detection and quantitation of positron emission mammography

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2001-01-01

    A Positron Emission Mammography (PEM) scanner dedicated to breast imaging is being developed at our laboratory. We have developed a list mode likelihood reconstruction algorithm for this scanner. Here we theoretically study the lesion detection and quantitation. The lesion detectability is studied theoretically using computer observers. We found that for the zero-order quadratic prior, the region of interest observer can achieve the performance of the prewhitening observer with a properly selected smoothing parameter. We also study the lesion quantitation using the test statistic of the region of interest observer. The theoretical expressions for the bias, variance, and ensemble mean squared error of the quantitation are derived. Computer simulations show that the theoretical predictions are in good agreement with the Monte Carlo results for both lesion detection and quantitation

  15. Automated detection of Lupus white matter lesions in MRI

    Directory of Open Access Journals (Sweden)

    Eloy Roura Perez

    2016-08-01

    Full Text Available Brain magnetic resonance imaging provides detailed information which can be used to detect and segment white matter lesions (WML. In this work we propose an approach to automatically segment WML in Lupus patients by using T1w and fluid-attenuated inversion recovery (FLAIR images. Lupus WML appear as small focal abnormal tissue observed as hyperintensities in the FLAIR images. The quantification of these WML is a key factor for the stratification of lupus patients and therefore both lesion detection and segmentation play an important role. In our approach, the T1w image is first used to classify the three main tissues of the brain, white matter (WM, gray matter (GM and cerebrospinal fluid (CSF, while the FLAIR image is then used to detect focal WML as outliers of its GM intensity distribution. A set of post-processing steps based on lesion size, tissue neighborhood, and location are used to refine the lesion candidates. The proposal is evaluated on 20 patients, presenting qualitative and quantitative results in terms of precision and sensitivity of lesion detection (True Positive Rate (62% and Positive Prediction Value (80% respectively as well as segmentation accuracy (Dice Similarity Coefficient (72%. Obtained results illustrate the validity of the approach to automatically detect and segment lupus lesions. Besides, our approach is publicly available as a SPM8/12 toolbox extension with a simple parameter configuration.

  16. Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network

    Directory of Open Access Journals (Sweden)

    Yuexiang Li

    2018-02-01

    Full Text Available Skin lesions are a severe disease globally. Early detection of melanoma in dermoscopy images significantly increases the survival rate. However, the accurate recognition of melanoma is extremely challenging due to the following reasons: low contrast between lesions and skin, visual similarity between melanoma and non-melanoma lesions, etc. Hence, reliable automatic detection of skin tumors is very useful to increase the accuracy and efficiency of pathologists. In this paper, we proposed two deep learning methods to address three main tasks emerging in the area of skin lesion image processing, i.e., lesion segmentation (task 1, lesion dermoscopic feature extraction (task 2 and lesion classification (task 3. A deep learning framework consisting of two fully convolutional residual networks (FCRN is proposed to simultaneously produce the segmentation result and the coarse classification result. A lesion index calculation unit (LICU is developed to refine the coarse classification results by calculating the distance heat-map. A straight-forward CNN is proposed for the dermoscopic feature extraction task. The proposed deep learning frameworks were evaluated on the ISIC 2017 dataset. Experimental results show the promising accuracies of our frameworks, i.e., 0.753 for task 1, 0.848 for task 2 and 0.912 for task 3 were achieved.

  17. Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network.

    Science.gov (United States)

    Li, Yuexiang; Shen, Linlin

    2018-02-11

    Skin lesions are a severe disease globally. Early detection of melanoma in dermoscopy images significantly increases the survival rate. However, the accurate recognition of melanoma is extremely challenging due to the following reasons: low contrast between lesions and skin, visual similarity between melanoma and non-melanoma lesions, etc. Hence, reliable automatic detection of skin tumors is very useful to increase the accuracy and efficiency of pathologists. In this paper, we proposed two deep learning methods to address three main tasks emerging in the area of skin lesion image processing, i.e., lesion segmentation (task 1), lesion dermoscopic feature extraction (task 2) and lesion classification (task 3). A deep learning framework consisting of two fully convolutional residual networks (FCRN) is proposed to simultaneously produce the segmentation result and the coarse classification result. A lesion index calculation unit (LICU) is developed to refine the coarse classification results by calculating the distance heat-map. A straight-forward CNN is proposed for the dermoscopic feature extraction task. The proposed deep learning frameworks were evaluated on the ISIC 2017 dataset. Experimental results show the promising accuracies of our frameworks, i.e., 0.753 for task 1, 0.848 for task 2 and 0.912 for task 3 were achieved.

  18. Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network

    Science.gov (United States)

    2018-01-01

    Skin lesions are a severe disease globally. Early detection of melanoma in dermoscopy images significantly increases the survival rate. However, the accurate recognition of melanoma is extremely challenging due to the following reasons: low contrast between lesions and skin, visual similarity between melanoma and non-melanoma lesions, etc. Hence, reliable automatic detection of skin tumors is very useful to increase the accuracy and efficiency of pathologists. In this paper, we proposed two deep learning methods to address three main tasks emerging in the area of skin lesion image processing, i.e., lesion segmentation (task 1), lesion dermoscopic feature extraction (task 2) and lesion classification (task 3). A deep learning framework consisting of two fully convolutional residual networks (FCRN) is proposed to simultaneously produce the segmentation result and the coarse classification result. A lesion index calculation unit (LICU) is developed to refine the coarse classification results by calculating the distance heat-map. A straight-forward CNN is proposed for the dermoscopic feature extraction task. The proposed deep learning frameworks were evaluated on the ISIC 2017 dataset. Experimental results show the promising accuracies of our frameworks, i.e., 0.753 for task 1, 0.848 for task 2 and 0.912 for task 3 were achieved. PMID:29439500

  19. Detection of pathogens from periodontal lesions

    Directory of Open Access Journals (Sweden)

    Malheiros Veruska de João

    2004-01-01

    Full Text Available OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.

  20. Iron and Non-Iron-Related Characteristics of Multiple Sclerosis and Neuromyelitis Optica Lesions at 7T MRI.

    Science.gov (United States)

    Chawla, S; Kister, I; Wuerfel, J; Brisset, J-C; Liu, S; Sinnecker, T; Dusek, P; Haacke, E M; Paul, F; Ge, Y

    2016-07-01

    Characterization of iron deposition associated with demyelinating lesions of multiple sclerosis and neuromyelitis optica has not been well studied. Our aim was to investigate the potential of ultra-high-field MR imaging to distinguish MS from neuromyelitis optica and to characterize tissue injury associated with iron pathology within lesions. Twenty-one patients with MS and 21 patients with neuromyelitis optica underwent 7T high-resolution 2D-gradient-echo-T2* and 3D-susceptibility-weighted imaging. An in-house-developed algorithm was used to reconstruct quantitative susceptibility mapping from SWI. Lesions were classified as "iron-laden" if they demonstrated hypointensity on gradient-echo-T2*-weighted images and/or SWI and hyperintensity on quantitative susceptibility mapping. Lesions were considered "non-iron-laden" if they were hyperintense on gradient-echo-T2* and isointense or hyperintense on quantitative susceptibility mapping. Of 21 patients with MS, 19 (90.5%) demonstrated at least 1 quantitative susceptibility mapping-hyperintense lesion, and 11/21 (52.4%) had iron-laden lesions. No quantitative susceptibility mapping-hyperintense or iron-laden lesions were observed in any patients with neuromyelitis optica. Iron-laden and non-iron-laden lesions could each be further characterized into 2 distinct patterns based on lesion signal and morphology on gradient-echo-T2*/SWI and quantitative susceptibility mapping. In MS, most lesions (n = 262, 75.9% of all lesions) were hyperintense on gradient-echo T2* and isointense on quantitative susceptibility mapping (pattern A), while a small minority (n = 26, 7.5% of all lesions) were hyperintense on both gradient-echo-T2* and quantitative susceptibility mapping (pattern B). Iron-laden lesions (n = 57, 16.5% of all lesions) were further classified as nodular (n = 22, 6.4%, pattern C) or ringlike (n = 35, 10.1%, pattern D). Ultra-high-field MR imaging may be useful in distinguishing MS from neuromyelitis optica. Different

  1. Novel fMRI working memory paradigm accurately detects cognitive impairment in multiple sclerosis.

    Science.gov (United States)

    Nelson, Flavia; Akhtar, Mohammad A; Zúñiga, Edward; Perez, Carlos A; Hasan, Khader M; Wilken, Jeffrey; Wolinsky, Jerry S; Narayana, Ponnada A; Steinberg, Joel L

    2017-05-01

    Cognitive impairment (CI) cannot be diagnosed by magnetic resonance imaging (MRI). Functional magnetic resonance imaging (fMRI) paradigms, such as the immediate/delayed memory task (I/DMT), detect varying degrees of working memory (WM). Preliminary findings using I/DMT showed differences in blood oxygenation level dependent (BOLD) activation between impaired (MSCI, n = 12) and non-impaired (MSNI, n = 9) multiple sclerosis (MS) patients. The aim of the study was to confirm CI detection based on I/DMT BOLD activation in a larger cohort of MS patients. The role of T2 lesion volume (LV) and Expanded Disability Status Scale (EDSS) in magnitude of BOLD signal was also sought. A total of 50 patients (EDSS mean ( m) = 3.2, disease duration (DD) m = 12 years, and age m = 40 years) underwent the Minimal Assessment of Cognitive Function in Multiple Sclerosis (MACFIMS) and I/DMT. Working memory activation (WMa) represents BOLD signal during DMT minus signal during IMT. CI was based on MACFIMS. A total of 10 MSNI, 30 MSCI, and 4 borderline patients were included in the analyses. Analysis of variance (ANOVA) showed MSNI had significantly greater WMa than MSCI, in the left prefrontal cortex and left supplementary motor area ( p = 0.032). Regression analysis showed significant inverse correlations between WMa and T2 LV/EDSS in similar areas ( p = 0.005, 0.004, respectively). I/DMT-based BOLD activation detects CI in MS. Larger studies are needed to confirm these findings.

  2. [Correlation between demyelinating lesions and executive function decline in a sample of Mexican patients with multiple sclerosis].

    Science.gov (United States)

    Aldrete Cortez, V R; Duriez-Sotelo, E; Carrillo-Mora, P; Pérez-Zuno, J A

    2013-09-01

    Multiple Sclerosis (MS) is characterised by several neurological symptoms including cognitive impairment, which has recently been the subject of considerable study. At present, evidence pointing to a correlation between lesion characteristics and specific cognitive impairment is not conclusive. To investigate the presence of a correlation between the characteristics of demyelinating lesions and performance of basic executive functions in a sample of MS patients. We included 21 adult patients with scores of 0 to 5 on the Kurtzke scale and no exacerbations of the disease in at least 3 months prior to the evaluation date. They completed the Stroop test and the Wisconsin Card Sorting Test (WCST). The location of the lesions was determined using magnetic resonance imaging (MRI) performed by a blinded expert in neuroimaging. Demyelinating lesions were more frequently located in the frontal and occipital lobes. The Stroop test showed that as cognitive demand increased on each of the sections in the test, reaction time and number of errors increased. On the WCST, 33.33% of patients registered as having moderate cognitive impairment. No correlation could be found between demyelinating lesion characteristics (location, size, and number) and patients' scores on the tests. Explanations of the causes of cognitive impairment in MS should examine a variety of biological, psychological, and social factors instead of focusing solely on demyelinating lesions. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  3. Correlation between white matter damage and gray matter lesions in multiple sclerosis patients

    Directory of Open Access Journals (Sweden)

    Xue-mei Han

    2017-01-01

    Full Text Available We observed the characteristics of white matter fibers and gray matter in multiple sclerosis patients, to identify changes in diffusion tensor imaging fractional anisotropy values following white matter fiber injury. We analyzed the correlation between fractional anisotropy values and changes in whole-brain gray matter volume. The participants included 20 patients with relapsing-remitting multiple sclerosis and 20 healthy volunteers as controls. All subjects underwent head magnetic resonance imaging and diffusion tensor imaging. Our results revealed that fractional anisotropy values decreased and gray matter volumes were reduced in the genu and splenium of corpus callosum, left anterior thalamic radiation, hippocampus, uncinate fasciculus, right corticospinal tract, bilateral cingulate gyri, and inferior longitudinal fasciculus in multiple sclerosis patients. Gray matter volumes were significantly different between the two groups in the right frontal lobe (superior frontal, middle frontal, precentral, and orbital gyri, right parietal lobe (postcentral and inferior parietal gyri, right temporal lobe (caudate nucleus, right occipital lobe (middle occipital gyrus, right insula, right parahippocampal gyrus, and left cingulate gyrus. The voxel sizes of atrophic gray matter positively correlated with fractional anisotropy values in white matter association fibers in the patient group. These findings suggest that white matter fiber bundles are extensively injured in multiple sclerosis patients. The main areas of gray matter atrophy in multiple sclerosis are the frontal lobe, parietal lobe, caudate nucleus, parahippocampal gyrus, and cingulate gyrus. Gray matter atrophy is strongly associated with white matter injury in multiple sclerosis patients, particularly with injury to association fibers.

  4. Deep 3D Convolutional Encoder Networks With Shortcuts for Multiscale Feature Integration Applied to Multiple Sclerosis Lesion Segmentation.

    Science.gov (United States)

    Brosch, Tom; Tang, Lisa Y W; Youngjin Yoo; Li, David K B; Traboulsee, Anthony; Tam, Roger

    2016-05-01

    We propose a novel segmentation approach based on deep 3D convolutional encoder networks with shortcut connections and apply it to the segmentation of multiple sclerosis (MS) lesions in magnetic resonance images. Our model is a neural network that consists of two interconnected pathways, a convolutional pathway, which learns increasingly more abstract and higher-level image features, and a deconvolutional pathway, which predicts the final segmentation at the voxel level. The joint training of the feature extraction and prediction pathways allows for the automatic learning of features at different scales that are optimized for accuracy for any given combination of image types and segmentation task. In addition, shortcut connections between the two pathways allow high- and low-level features to be integrated, which enables the segmentation of lesions across a wide range of sizes. We have evaluated our method on two publicly available data sets (MICCAI 2008 and ISBI 2015 challenges) with the results showing that our method performs comparably to the top-ranked state-of-the-art methods, even when only relatively small data sets are available for training. In addition, we have compared our method with five freely available and widely used MS lesion segmentation methods (EMS, LST-LPA, LST-LGA, Lesion-TOADS, and SLS) on a large data set from an MS clinical trial. The results show that our method consistently outperforms these other methods across a wide range of lesion sizes.

  5. Dipyridamole thallium imaging for detecting cardiac involvement in patients with systemic sclerosis (scleroderma)

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Matsubara, Noboru; Tani, Akihiro; Morozumi, Takakazu; Hori, Masatsugu; Kitabatake, Akira; Kamada, Takenobu; Kimura, Kazufumi; Kozuka, Takahiro (Osaka Univ. (Japan). Faculty of Medicine)

    1990-02-01

    Dipyridamole thallium-201 imaging was carried out in 21 patients with progressive systemic sclerosis (PSS) to assess its value in detecting impaired myocardium and coronary microcirculation associated with PSS. Depending upon the degree of cardiac function, the patients were classified as having either ejection fraction of 50% or more (Group I, n=17) or less than 50% (Group II, n=4). In Group I, four patients had transient defect in which perfusion defects were seen on early images but not seen on delayed images; three had reverse redistribution in which defects were not seen on early images but seen on delayed images; and three had persistent defects which were seen on both early and delayed images. A decreased washout of thallium-201 was seen in 9 patients. In an analysis of both perfusion defects and washout rate, 13 patients (76%) in Group I were found to have abnormal findings. This suggests that disturbed coronary microcirculation or impaired myocardium may frequently develop even when EF is normal. All of the patients categorized as having a decreased cardiac function (Group II) had perfusion defect, suggesting the presence of myocardial fibrosis. In PSS, deterioration of cardiac function seemed to be associated with progression of myocardial fibrosis. Dipyridamole thallium imaging may be a sensitive method for detecting cardiac lesions in PSS. It also has the potential for detecting decreased coronary flow reserve or slightly impaired myocardium even without decreased EF. (N.K.).

  6. Detection of small human cerebral cortical lesions with MRI under different levels of Gaussian smoothing: applications in epilepsy

    Science.gov (United States)

    Cantor-Rivera, Diego; Goubran, Maged; Kraguljac, Alan; Bartha, Robert; Peters, Terry

    2010-03-01

    The main objective of this study was to assess the effect of smoothing filter selection in Voxel-Based Morphometry studies on structural T1-weighted magnetic resonance images. Gaussian filters of 4 mm, 8 mm or 10 mm Full Width at High Maximum are commonly used, based on the assumption that the filter size should be at least twice the voxel size to obtain robust statistical results. The hypothesis of the presented work was that the selection of the smoothing filter influenced the detectability of small lesions in the brain. Mesial Temporal Sclerosis associated to Epilepsy was used as the case to demonstrate this effect. Twenty T1-weighted MRIs from the BrainWeb database were selected. A small phantom lesion was placed in the amygdala, hippocampus, or parahippocampal gyrus of ten of the images. Subsequently the images were registered to the ICBM/MNI space. After grey matter segmentation, a T-test was carried out to compare each image containing a phantom lesion with the rest of the images in the set. For each lesion the T-test was repeated with different Gaussian filter sizes. Voxel-Based Morphometry detected some of the phantom lesions. Of the three parameters considered: location,size, and intensity; it was shown that location is the dominant factor for the detection of the lesions.

  7. Detection of inflammatory lesions with radiolabelled immunoglobulins

    International Nuclear Information System (INIS)

    Blok, D.; Rijksuniversiteit Leiden; Ogtrop, M. van; Arndt, J.W.; Camps, J.A.J.; Feitsma, R.I.J.; Pauwels, E.K.J.

    1990-01-01

    Previous reports on the use of radiolabelled immunoglobulins led us to undertake a pilot experiment in an animal model to investigate the potentials sodium pertechnate Tc 99m-immunoglobulin scintigraphy in the detection of infectious foci. Mice infected in one leg with staphylococcus infection in were injected with sodium pertechnote Tc 99m-immunoglobulin, albumin aggregated technetium Tc 99m or gallium citrate Ga 67. The results obtained by scintigraphy suggested a specific accumulation of radiolabelled immunoglobulin at the site of infection. Visualization of the infection and the image quality, especially the 6- and 24-h images, were clearly enhanced after the use of immunoglobulin preparations as compared with those labelled with gallium. (orig.)

  8. Do positive or negative stressful events predict the development of new brain lesions in people with Multiple Sclerosis?

    Science.gov (United States)

    Burns, Michelle Nicole; Nawacki, Ewa; Kwasny, Mary J.; Pelletier, Daniel; Mohr, David C.

    2014-01-01

    Background Stressful life events have long been suspected to contribute to multiple sclerosis (MS) disease activity. The few studies examining the relationship between stressful events and neuroimaging markers have been small and inconsistent. This study examined whether different types of stressful events and perceived stress could predict development of brain lesions. Methods This was a secondary analysis of 121 patients with MS followed for 48 weeks during a randomized controlled trial comparing Stress Management Therapy for MS to a waitlist control. Patients underwent MRI’s every 8 weeks. Monthly, patients completed an interview measure assessing stressful life events, and self-report measures of perceived stress, anxiety, and depressive symptoms, which were used to predict the presence of gadolinium enhancing (Gd+) and T2 lesions on MRI’s 29–62 days later. Participants classified stressful events as positive or negative. Negative events were considered “major” if they involved physical threat or threat to the patient’s family structure, and “moderate” otherwise. Results Positive stressful events predicted decreased risk for subsequent Gd+ lesions in the control group (OR=.53 for each additional positive stressful event, 95% CI=.30–.91) and less risk for new or enlarging T2 lesions regardless of group assignment (OR=.74, 95% CI=.55–.99). Across groups, major negative stressful events predicted Gd+ lesions (OR=1.77, 95% CI=1.18–2.64) and new or enlarging T2 lesions (OR=1.57, 95% CI=1.11–2.23), while moderate negative stressful events, perceived stress, anxiety, and depressive symptoms did not. Conclusions Major negative stressful events predict increased risk for Gd+ and T2 lesions, while positive stressful events predict decreased risk. PMID:23680407

  9. Serum levels of brain-derived neurotrophicfactor correlate with the number of T2 MRI lesions in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    E.R. Comini-Frota

    2012-01-01

    Full Text Available The objective of the present study was to determine if there is a relationship between serum levels of brain-derived neurotrophic factor (BDNF and the number of T2/fluid-attenuated inversion recovery (T2/FLAIR lesions in multiple sclerosis (MS. The use of magnetic resonance imaging (MRI has revolutionized the study of MS. However, MRI has limitations and the use of other biomarkers such as BDNF may be useful for the clinical assessment and the study of the disease. Serum was obtained from 28 MS patients, 18-50 years old (median 38, 21 women, 0.5-10 years (median 5 of disease duration, EDSS 1-4 (median 1.5 and 28 healthy controls, 19-49 years old (median 33, 19 women. BDNF levels were measured by ELISA. T1, T2/FLAIR and gadolinium-enhanced lesions were measured by a trained radiologist. BDNF was reduced in MS patients (median [range] pg/mL; 1160 [352.6-2640] compared to healthy controls (1640 [632.4-4268]; P = 0.03, Mann-Whitney test and was negatively correlated (Spearman correlation test, r = -0.41; P = 0.02 with T2/FLAIR (11-81 lesions, median 42. We found that serum BDNF levels were inversely correlated with the number of T2/FLAIR lesions in patients with MS. BDNF may be a promising biomarker of MS.

  10. Serum levels of brain-derived neurotrophic factor correlate with the number of T2 MRI lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Comini-Frota, E.R.; Rodrigues, D.H.; Miranda, E.C.; Brum, D.G.; Kaimen-Maciel, D.R.; Donadi, E.A.; Teixeira, A.L.

    2011-01-01

    The objective of the present study was to determine if there is a relationship between serum levels of brain-derived neurotrophic factor (BDNF) and the number of T2/fluid-attenuated inversion recovery (T2/FLAIR) lesions in multiple sclerosis (MS). The use of magnetic resonance imaging (MRI) has revolutionized the study of MS. However, MRI has limitations and the use of other biomarkers such as BDNF may be useful for the clinical assessment and the study of the disease. Serum was obtained from 28 MS patients, 18-50 years old (median 38), 21 women, 0.5-10 years (median 5) of disease duration, EDSS 1-4 (median 1.5) and 28 healthy controls, 19-49 years old (median 33), 19 women. BDNF levels were measured by ELISA. T1, T2/FLAIR and gadolinium-enhanced lesions were measured by a trained radiologist. BDNF was reduced in MS patients (median [range] pg/mL; 1160 [352.6-2640]) compared to healthy controls (1640 [632.4-4268]; P = 0.03, Mann-Whitney test) and was negatively correlated (Spearman correlation test, r = -0.41; P = 0.02) with T2/FLAIR (11-81 lesions, median 42). We found that serum BDNF levels were inversely correlated with the number of T2/FLAIR lesions in patients with MS. BDNF may be a promising biomarker of MS

  11. Serum levels of brain-derived neurotrophic factor correlate with the number of T2 MRI lesions in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Comini-Frota, E.R. [Unidade de Neurologia, Hospital Universitário, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Rodrigues, D.H. [Laboratório de Imunofarmacologia, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Miranda, E.C. [Ecoar Diagnostic Center, Belo Horizonte, MG (Brazil); Brum, D.G. [Hospital das Clínicas,Faculdade de Medicina de Ribeirão Preto,Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Kaimen-Maciel, D.R. [Unidade de Neurologia, Hospital Universitário, Universidade Estadual de Londrina, Londrina, PR (Brazil); Donadi, E.A. [Hospital das Clínicas,Faculdade de Medicina de Ribeirão Preto,Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Teixeira, A.L. [Unidade de Neurologia, Hospital Universitário, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Laboratório de Imunofarmacologia, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2011-11-23

    The objective of the present study was to determine if there is a relationship between serum levels of brain-derived neurotrophic factor (BDNF) and the number of T2/fluid-attenuated inversion recovery (T2/FLAIR) lesions in multiple sclerosis (MS). The use of magnetic resonance imaging (MRI) has revolutionized the study of MS. However, MRI has limitations and the use of other biomarkers such as BDNF may be useful for the clinical assessment and the study of the disease. Serum was obtained from 28 MS patients, 18-50 years old (median 38), 21 women, 0.5-10 years (median 5) of disease duration, EDSS 1-4 (median 1.5) and 28 healthy controls, 19-49 years old (median 33), 19 women. BDNF levels were measured by ELISA. T1, T2/FLAIR and gadolinium-enhanced lesions were measured by a trained radiologist. BDNF was reduced in MS patients (median [range] pg/mL; 1160 [352.6-2640]) compared to healthy controls (1640 [632.4-4268]; P = 0.03, Mann-Whitney test) and was negatively correlated (Spearman correlation test, r = -0.41; P = 0.02) with T2/FLAIR (11-81 lesions, median 42). We found that serum BDNF levels were inversely correlated with the number of T2/FLAIR lesions in patients with MS. BDNF may be a promising biomarker of MS.

  12. Red lesion detection using background estimation and lesions characteristics in diabetic retinal image

    Science.gov (United States)

    Zhang, Dongbo; Peng, Yinghui; Yi, Yao; Shang, Xingyu

    2013-10-01

    Detection of red lesions [hemorrhages (HRs) and microaneurysms (MAs)] is crucial for the diagnosis of early diabetic retinopathy. A method based on background estimation and adapted to specific characteristics of HRs and MAs is proposed. Candidate red lesions are located by background estimation and Mahalanobis distance measure and then some adaptive postprocessing techniques, which include vessel detection, nonvessel exclusion based on shape analysis, and noise points exclusion by double-ring filter (only used for MAs detection), are conducted to remove nonlesion pixels. The method is evaluated on our collected image dataset, and experimental results show that it is better than or approximate to other previous approaches. It is effective to reduce the false-positive and false-negative results that arise from incomplete and inaccurate vessel structure.

  13. Detection of infarct lesions from single MRI modality using inconsistency between voxel intensity and spatial location--a 3-D automatic approach.

    Science.gov (United States)

    Shen, Shan; Szameitat, André J; Sterr, Annette

    2008-07-01

    Detection of infarct lesions using traditional segmentation methods is always problematic due to intensity similarity between lesions and normal tissues, so that multispectral MRI modalities were often employed for this purpose. However, the high costs of MRI scan and the severity of patient conditions restrict the collection of multiple images. Therefore, in this paper, a new 3-D automatic lesion detection approach was proposed, which required only a single type of anatomical MRI scan. It was developed on a theory that, when lesions were present, the voxel-intensity-based segmentation and the spatial-location-based tissue distribution should be inconsistent in the regions of lesions. The degree of this inconsistency was calculated, which indicated the likelihood of tissue abnormality. Lesions were identified when the inconsistency exceeded a defined threshold. In this approach, the intensity-based segmentation was implemented by the conventional fuzzy c-mean (FCM) algorithm, while the spatial location of tissues was provided by prior tissue probability maps. The use of simulated MRI lesions allowed us to quantitatively evaluate the performance of the proposed method, as the size and location of lesions were prespecified. The results showed that our method effectively detected lesions with 40-80% signal reduction compared to normal tissues (similarity index > 0.7). The capability of the proposed method in practice was also demonstrated on real infarct lesions from 15 stroke patients, where the lesions detected were in broad agreement with true lesions. Furthermore, a comparison to a statistical segmentation approach presented in the literature suggested that our 3-D lesion detection approach was more reliable. Future work will focus on adapting the current method to multiple sclerosis lesion detection.

  14. Automated Breast Ultrasound Lesions Detection using Convolutional Neural Networks.

    Science.gov (United States)

    Yap, Moi Hoon; Pons, Gerard; Marti, Joan; Ganau, Sergi; Sentis, Melcior; Zwiggelaar, Reyer; Davison, Adrian K; Marti, Robert

    2017-08-07

    Breast lesion detection using ultrasound imaging is considered an important step of Computer-Aided Diagnosis systems. Over the past decade, researchers have demonstrated the possibilities to automate the initial lesion detection. However, the lack of a common dataset impedes research when comparing the performance of such algorithms. This paper proposes the use of deep learning approaches for breast ultrasound lesion detection and investigates three different methods: a Patch-based LeNet, a U-Net, and a transfer learning approach with a pretrained FCN-AlexNet. Their performance is compared against four state-of-the-art lesion detection algorithms (i.e. Radial Gradient Index, Multifractal Filtering, Rule-based Region Ranking and Deformable Part Models). In addition, this paper compares and contrasts two conventional ultrasound image datasets acquired from two different ultrasound systems. Dataset A comprises 306 (60 malignant and 246 benign) images and Dataset B comprises 163 (53 malignant and 110 benign) images. To overcome the lack of public datasets in this domain, Dataset B will be made available for research purposes. The results demonstrate an overall improvement by the deep learning approaches when assessed on both datasets in terms of True Positive Fraction, False Positives per image, and F-measure.

  15. Association of Cortical Lesion Burden on 7-T Magnetic Resonance Imaging With Cognition and Disability in Multiple Sclerosis.

    Science.gov (United States)

    Harrison, Daniel M; Roy, Snehashis; Oh, Jiwon; Izbudak, Izlem; Pham, Dzung; Courtney, Susan; Caffo, Brian; Jones, Craig K; van Zijl, Peter; Calabresi, Peter A

    2015-09-01

    Cortical lesions (CLs) contribute to physical and cognitive disability in multiple sclerosis (MS). Accurate methods for visualization of CLs are necessary for future clinical studies and therapeutic trials in MS. To evaluate the clinical relevance of measures of CL burden derived from high-field magnetic resonance imaging (MRI) in MS. An observational clinical imaging study was conducted at an academic MS center. Participants included 36 individuals with MS (30 relapsing-remitting, 6 secondary or primary progressive) and 15 healthy individuals serving as controls. The study was conducted from March 10, 2010, to November 23, 2012, and analysis was performed from June 1, 2011, to September 30, 2014. Seven-Tesla MRI of the brain was performed with 0.5-mm isotropic resolution magnetization-prepared rapid acquisition gradient echo (MPRAGE) and whole-brain, 3-dimensional, 1.0-mm isotropic resolution magnetization-prepared, fluid-attenuated inversion recovery (MPFLAIR). Cortical lesions, seen as hypointensities on MPRAGE, were manually segmented. Lesions were classified as leukocortical, intracortical, or subpial. Images were segmented using the Lesion-TOADS (Topology-Preserving Anatomical Segmentation) algorithm, and brain structure volumes and white matter (WM) lesion volume were reported. Volumes were normalized to intracranial volume. Physical disability was measured by the Expanded Disability Status Scale (EDSS). Cognitive disability was measured with the Minimal Assessment of Cognitive Function in MS battery. Cortical lesions were noted in 35 of 36 participants (97%), with a median of 16 lesions per participant (range, 0-99). Leukocortical lesion volume correlated with WM lesion volume (ρ = 0.50; P = .003) but not with cortical volume; subpial lesion volume inversely correlated with cortical volume (ρ = -0.36; P = .04) but not with WM lesion volume. Total CL count and volume, measured as median (range), were significantly increased in participants

  16. Medical Imaging Lesion Detection Based on Unified Gravitational Fuzzy Clustering

    Directory of Open Access Journals (Sweden)

    Jean Marie Vianney Kinani

    2017-01-01

    Full Text Available We develop a swift, robust, and practical tool for detecting brain lesions with minimal user intervention to assist clinicians and researchers in the diagnosis process, radiosurgery planning, and assessment of the patient’s response to the therapy. We propose a unified gravitational fuzzy clustering-based segmentation algorithm, which integrates the Newtonian concept of gravity into fuzzy clustering. We first perform fuzzy rule-based image enhancement on our database which is comprised of T1/T2 weighted magnetic resonance (MR and fluid-attenuated inversion recovery (FLAIR images to facilitate a smoother segmentation. The scalar output obtained is fed into a gravitational fuzzy clustering algorithm, which separates healthy structures from the unhealthy. Finally, the lesion contour is automatically outlined through the initialization-free level set evolution method. An advantage of this lesion detection algorithm is its precision and its simultaneous use of features computed from the intensity properties of the MR scan in a cascading pattern, which makes the computation fast, robust, and self-contained. Furthermore, we validate our algorithm with large-scale experiments using clinical and synthetic brain lesion datasets. As a result, an 84%–93% overlap performance is obtained, with an emphasis on robustness with respect to different and heterogeneous types of lesion and a swift computation time.

  17. Texture alteration detection in bitemporal images of lesions with psoriasis

    DEFF Research Database (Denmark)

    Maletti, Gabriela Mariel; Ersbøll, Bjarne Kjær

    2003-01-01

    The objective of this work is to explore the feasibility of quantifying textural change between pairs of segmented patterns without registering them. The Multi-variate Alteration Detection (M.A.D.) Transform is applied to a texture model constructed with the data of segmented psoriasis lesions im...... images. The texture model is Haralick's co-occurrence matrix, which is computed and normalized for each single band with the equalized data of a given lesion. The contribution of each single color band to the textural change is analyzed....

  18. Computerized detection of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Yin, F.F.; Giger, M.L.; Doi, K.; Metz, C.E.; Vyborny, C.J.; Schmidt, R.A.

    1989-01-01

    Early detection of breast cancer from the periodic screening of asymptomatic women could reduce breast cancer mortality by at least 40%. The authors are developing a computerized scheme for the detection of mass lesions in digital mammograms as an aid to radiologists in such high volume screening programs. Based on left-right architectural symmetry and gray-level histogram analysis, bilateral subtraction of left and right breast images is performed. False-positive detections included in bilateral-difference images are reduced with various images feature-extraction techniques. The database involves clinical film mammograms digitized by a TV camera and analyzed on a Micro-VAX workstation. Among five different bilateral subtraction techniques investigated, a nonlinear approach provided superior lesion enhancement. Feature-extraction techniques reduced substantially the remaining false-positives. Preliminary results, for 32 pairs of clinical mammograms, yielded a true-positive rate of approximately 95% with a false-positive rate of about 2 per image

  19. Measles IgG antibody index correlates with T2 lesion load on MRI in patients with early multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Berit Rosche

    Full Text Available BACKGROUND: B cells and humoral immune responses play an important role in the pathogenesis and diagnosis of multiple sclerosis (MS. A characteristic finding in patients with MS is a polyspecific intrathecal B cell response against neurotropic viruses, specifically against measles virus, rubella virus, and varicella zoster virus, also known as an MRZ reaction (MRZR. Here, we correlated from the routine clinical diagnostics individual IgG antibody indices (AIs of MRZR with magnetic resonance imaging (MRI findings in patients with first MS diagnosis. METHODS/RESULTS: MRZR was determined in 68 patients with a clinically isolated syndrome (CIS or early relapsing-remitting MS (RRMS. Absolute AI values for measles virus, rubella virus, and varicella zoster virus were correlated with T2 lesion load and gadolinium enhancing lesions on cerebral MRI (cMRI and cMRI combined with spinal MRI (sMRI. Measles virus AI correlated significantly with T2 lesion load on cMRI (p = 0.0312, Mann-Whitney U test and the sum of lesions on cMRI and sMRI (p = 0.0413. Varicella zoster virus AI also showed a correlation with T2 lesion load on cMRI but did not reach statistical significance (p = 0.2893. CONCLUSION: The results confirm MRZR as part of the polyspecific immune reaction in MS with possible prognostic impact on MRI and clinical parameters. Furthermore, the data indicate that intrathecal measles virus IgG production correlates with disease activity on cMRI and sMRI in patients with early MS.

  20. Brain white matter demyelinating lesions and amyotrophic lateral sclerosis in a patient with C9orf72 hexanucleotide repeat expansion.

    Science.gov (United States)

    Oliveira Santos, Miguel; Caldeira, Inês; Gromicho, Marta; Pronto-Laborinho, Ana; de Carvalho, Mamede

    2017-10-01

    A hexanucleotide repeat expansion in the C9orf72 gene is associated with amyotrophic lateral sclerosis (ALS) and frontotemporal lobar degeneration. It has been described before four patients with multiple sclerosis (MS) and C9orf72-ALS. However, C9orf72 positivity is not associated with increased risk of MS. Inflammatory pathways related to NF-κB have been linked to ALS and MS, and appear to be important in C9orf72-ALS patients. A 42-year-old woman presented with progressive bulbar symptoms for 9 months. Neurological examination disclosed spastic dysarthria, atrophic tongue with fasciculations, brisk jaw and limb tendon reflexes, and bilateral Hoffman sign. Electrophysiological assessment confirmed ALS. Brain MRI revealed multiple and bilateral juxtacortical and periventricular inflammatory changes, some with gadolinium-enhancement, configuring a probable MS-like pattern. CSF evaluation was unremarkable, with no oligoclonal bands. Visual and somatosensory evoked potentials were normal. Follow-up brain MRI 6 months later showed two new lesions in two relatively characteristic locations of MS, with no gadolinium-enhancement. Genetic screening revealed a C9orf72 expansion. As patient had no clinical manifestation of MS, a diagnosis of radiologically isolated syndrome was considered. We speculate that these demyelinating lesions might facilitate expressivity of C9orf72 expansion, through NF-κB activation. This plausible association may lead to the identification of a therapeutic target in this subgroup of C9orf72-ALS patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. IMAGE PROCESSING FOR DETECTION OF ORAL WHITE SPONGE NEVUS LESIONS

    Directory of Open Access Journals (Sweden)

    Rajdeep Mitra

    2016-12-01

    Full Text Available White Sponge Nevus is a rear hereditary disease in human causes incurable white lesions in oral mucosa. Appropriate history, clinical examination along with biopsy and cytological studies are helpful for diagnosis of this disorder. Identification can also be made in alternative way by applying image processing technique using Watershed segmentation with MATLAB software. The applied techniques are effective and reliable for early accurate detection of the disease as alternative of expertise clinical and time taking laboratory investigations.

  2. A new T2 lesion in a patient with the clinically isolated syndrome does not necessarily imply a conversion to multiple sclerosis.

    Science.gov (United States)

    Capone, Fioravante; Puthenparampil, Marco; Mallio, Carlo Augusto; Celia, Alessandra Ida; Florio, Lucia; Gallo, Paolo; Di Lazzaro, Vincenzo

    2018-01-01

    In the follow-up of patients with the clinically isolated syndrome, both clinical and MRI findings should be carefully evaluated by clinicians to avoid misinterpretation and inappropriate diagnosis of multiple sclerosis. We describe a case of a patient with a previous diagnosis of clinically isolated syndrome who developed a new asymptomatic brain lesion at the MRI follow-up. The careful evaluation of clinical history and radiological findings allowed the correct diagnosis of cocaine-associated ischemic stroke. Our case highlights that, in patients with the clinically isolated syndrome, the appearance of a new lesion on MRI does not necessarily imply a conversion to multiple sclerosis. Among "better explanations", ischemic lesions are of relevance and, in patients without typical risk factors for stroke, rarer causes such as cocaine assumption should be considered. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Visual Inspection Displays Good Accuracy for Detecting Caries Lesions

    DEFF Research Database (Denmark)

    Twetman, Svante

    2015-01-01

    /QUESTION: To evaluate the overall accuracy of visual methods for detecting caries lesions. SOURCE OF FUNDING: Brazilian government (Process 2012/17888-1). TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data LEVEL OF EVIDENCE: Level 1: Good-quality, patient-oriented evidence STRENGTH OF RECOMMENDATION......ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Visual inspection for caries detection: a systematic review and meta-analysis. Gimenez T, Piovesan C, Braga MM, Raggio DP, Deery C, Ricketts DN, Ekstrand DR, Mendes FM. J Dent Res 2015;94(7):895-904. REVIEWER: Svante Twetman, DDS, PhD, Odont Dr PURPOSE...

  4. Proliferative changes in nonpalpable breast lesions detected by mammography

    International Nuclear Information System (INIS)

    Vega, A.; Delgado, A.; Ortega, E.; Garijo, F.; Mosquera, J.; Sogo, C.; Alvarez, A.

    2000-01-01

    To analyze retrospectively the radiological findings in nonpalpable breast lesions detected by mammography that lead to the performance of surgical biopsy, resulting in a histological diagnosis of proliferative breast disease with and without atypia. From two Spanish hospitals, 421 women with 429 biopsies indicative of the presence of proliferative breast disease with and without atypia were selected out of a total of 1252 surgical biopsies in nonpalpable lesions that proved to be benign. Age, personal and familial history of breast cancer, reason for requesting the mammography and radiological findings that had indicated the need for surgical biopsy were recorded for each patient. The diagnosis was proliferative breast disease (epithelial hyperplasia) in 347 women with 354 biopsies and atypical hyperplasia in the remaining 74 women with 75 biopsies, representing 28% and 6%, respectively, of the 1252 biopsies of lesions found to be benign. In 221 of the 354 cases of epithelial hyperplasia (62%) and 45 of the 75 cases of atypical hyperplasia (60%), the presence of calcifications was the most common radiological findings leading to biopsy (p<0.05). Parenchymal distortion, with or without calcifications, was the second most common radiological sign. The histological study revealed a close relationship between these proliferative events and radial scars. Calcifications are the radiological finding that most frequently indicate the need for surgical biopsy in nonpalpable lesions that results in a diagnosis of proliferative breast disease with and without atypia. (Author) 12 refs

  5. Magnetic resonance imaging of multiple sclerosis brain lesions: A semeiologic study by multiple spin-echo sequences

    International Nuclear Information System (INIS)

    Caires, M.C.; Scheiber, C.; Rumbach, L.; Gounot, D.; Dumitresco, B.; Warter, J.M.; Collard, M.; Chambron, J.

    1986-01-01

    Nuclear magnetic resonance imaging (MRI) if the brain is now known as a very sensitive tool for clearly revealing lesions in white matter, and has thus become important in the study of multiple sclerosis (MS). Since 1981, others have shown the best of MRI: we can see 6 x more lesions than CT. MRI contrast bases mainly on the spatial heterogeneity of the relaxation time of different tissues. The sensitivity depends on the longer T1 and/or T2 of the pathological tissues compared to those of normal tissues. In our series, the authors use mainly T2 weighted MR images and they evaluate their interest for the diagnosis of MS. They study the frequency of the abnormalities and their semeiology in a small number of transversal sections imaged at the level of the lateral ventricles. The authors' aim is to describe the NMR-derived morphological signs of MS and to prospect its interest in the physiopathological studies of this disease

  6. Stereotaxic cytology of nonpalpable lesions detected at mammography

    International Nuclear Information System (INIS)

    Ciatto, S.; Rosselli del Turco, M.; Bravetti, P.; Catarzi, S.

    1991-01-01

    The authors report on 791 consecutive cases undergoing stereotaxic cytology for non palpable lesions detected at mammography. Histologic diagnosis (malignant = 179, benign = 107) or mammographic folow-up after at least one year (benign = 275) was available in 561 cases. The overall inadequacy rate of stereotaxic cytology was 0.21, and dependent on lesion type (benign = 0.25, malignant = 0.13 p<0.001) and on sampling operator experience (range 0.17-0.31, p<0.001). Sensitivity (dubious+positive, after exclusion of inadequates) was 0.83 and dependent on histologic type (infiltrating = 0.87, intraductal = 0.68). Specificity (negative/benign, after exclusion of inadequates) was 0.96. Stereotaxic cytology helped in reducing the number of unnecessary beningn biopsies and the biopsy ratio was 0.6 benign to 1 malignant biopsy. In cases with moderate suspicion at mammography the radiologist felt reassured by negative cytology and advised mammographic control rather than surgical biopsy. Cytology was determinant in advising surgical biopsy in 9 cancer cases whereas the absence of cytologic positivity contributed to diagnostic delay in 2 cancer cases. Overall, stereotaxic cytology allowed a relevant reduction of unnecessary benign biopsies and should be routinely employed in the diagnostic work-up of nonpalpable lesions detected at mammography

  7. Detection of intaoral lesions using a fluorescence camera

    Science.gov (United States)

    Thoms, Michael

    2006-02-01

    Optical methods for the detection of carious lesions, calculus and plaque have the advantage of being minimally invasive. The use of endogeneous fluorescence markers like porphyrins could simplify the application of fluorescence techniques in the dental practice. It is known that porphyrins are produced by some of the bacterial species that are present in the oral cavity. Since porphyrins have an excitation band at about 400nm they have the potential to be used as fluorescent markers of locations in the oral cavity where the production of bacteria is out of the limits of healthy regions. Further, modern and efficient GaN-based semiconductor diodes emit light in this spectral range and thus make the implementation of fluorescence sensors with excitation at this wavelength easy. Carious lesions, calculus and plaque have been measured using a self build fluorescence camera using GaN-diodes for illumination at 405nm. Further, emission spectra under this excitation were recorded. For the latter purpose freshly extracted teeth were used. It has been found that already in the case of an initial carious lesion red porphyrin-fluorescence is emitted whereas it is absent in healthy enamel. In already brown coloured carious lesions the emission bands of porphyrin are present but the observed overall fluorescence intensity is lower, probably due to the absorption of the fluorescence by the carious defect itself. In dental calculus, dental plaque and subgingival concrements porphyrin originated luminescence was found as well. Since in these cases the emission spectra differ slightly it can be concluded that they originate from different types of porphyrins and thus also from different bacteria. These results show that this fluorescence technique can be a promising method to diagnose carious lesions, calculus and plaque.

  8. Management of breast lesions detectable only on MRI

    International Nuclear Information System (INIS)

    Siegmann-Luz, K.C.; Bahrs, S.D.; Preibsch, H.; Hattermann, V.; Claussen, C.D.

    2014-01-01

    Breast MR imaging has become established as the most sensitive imaging method for diagnosing breast cancer. As a result of the increasing examination volume and improved image quality, the number of breast lesions detected only on MRI and requiring further clarification has risen in recent years. According to the S3-guideline 'Diagnosis, Therapy, and Follow-Up of Breast Cancer' as revised in July 2012, institutions performing breast MRI should provide the option of an MRI-guided intervention for clarification. This review describes the indications, methods and results of MRI-guided interventions for the clarification of breast lesions only visible on MRI. Recent guidelines and study results are also addressed and alternative methods and pitfalls are presented. (orig.)

  9. Automated detection of diabetic retinopathy lesions on ultrawidefield pseudocolour images.

    Science.gov (United States)

    Wang, Kang; Jayadev, Chaitra; Nittala, Muneeswar G; Velaga, Swetha B; Ramachandra, Chaithanya A; Bhaskaranand, Malavika; Bhat, Sandeep; Solanki, Kaushal; Sadda, SriniVas R

    2018-03-01

    We examined the sensitivity and specificity of an automated algorithm for detecting referral-warranted diabetic retinopathy (DR) on Optos ultrawidefield (UWF) pseudocolour images. Patients with diabetes were recruited for UWF imaging. A total of 383 subjects (754 eyes) were enrolled. Nonproliferative DR graded to be moderate or higher on the 5-level International Clinical Diabetic Retinopathy (ICDR) severity scale was considered as grounds for referral. The software automatically detected DR lesions using the previously trained classifiers and classified each image in the test set as referral-warranted or not warranted. Sensitivity, specificity and the area under the receiver operating curve (AUROC) of the algorithm were computed. The automated algorithm achieved a 91.7%/90.3% sensitivity (95% CI 90.1-93.9/80.4-89.4) with a 50.0%/53.6% specificity (95% CI 31.7-72.8/36.5-71.4) for detecting referral-warranted retinopathy at the patient/eye levels, respectively; the AUROC was 0.873/0.851 (95% CI 0.819-0.922/0.804-0.894). Diabetic retinopathy (DR) lesions were detected from Optos pseudocolour UWF images using an automated algorithm. Images were classified as referral-warranted DR with a high degree of sensitivity and moderate specificity. Automated analysis of UWF images could be of value in DR screening programmes and could allow for more complete and accurate disease staging. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Improved Detection of Microsatellite Instability in Early Colorectal Lesions.

    Directory of Open Access Journals (Sweden)

    Jeffery W Bacher

    Full Text Available Microsatellite instability (MSI occurs in over 90% of Lynch syndrome cancers and is considered a hallmark of the disease. MSI is an early event in colon tumor development, but screening polyps for MSI remains controversial because of reduced sensitivity compared to more advanced neoplasms. To increase sensitivity, we investigated the use of a novel type of marker consisting of long mononucleotide repeat (LMR tracts. Adenomas from 160 patients, ranging in age from 29-55 years old, were screened for MSI using the new markers and compared with current marker panels and immunohistochemistry standards. Overall, 15 tumors were scored as MSI-High using the LMRs compared to 9 for the NCI panel and 8 for the MSI Analysis System (Promega. This difference represents at least a 1.7-fold increase in detection of MSI-High lesions over currently available markers. Moreover, the number of MSI-positive markers per sample and the size of allelic changes were significantly greater with the LMRs (p = 0.001, which increased confidence in MSI classification. The overall sensitivity and specificity of the LMR panel for detection of mismatch repair deficient lesions were 100% and 96%, respectively. In comparison, the sensitivity and specificity of the MSI Analysis System were 67% and 100%; and for the NCI panel, 75% and 97%. The difference in sensitivity between the LMR panel and the other panels was statistically significant (p<0.001. The increased sensitivity for detection of MSI-High phenotype in early colorectal lesions with the new LMR markers indicates that MSI screening for the early detection of Lynch syndrome might be feasible.

  11. Optimisation of T{sub 2}{sup *}-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Jennifer Elizabeth, E-mail: jennifer.dixon@nottingham.ac.uk [Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD (United Kingdom); Simpson, Ashley, E-mail: ashley.simpson@nhs.net [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Mistry, Niraj, E-mail: niraj.mistry@nottingham.ac.uk [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Evangelou, Nikos, E-mail: nikos.evangelou@nuh.nhs.uk [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Morris, Peter Gordon, E-mail: peter.morris@nottingham.ac.uk [Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD (United Kingdom)

    2013-05-15

    T{sub 2}{sup *}-weighted magnetic resonance imaging at 7 T has recently been shown to allow differentiation between white-matter multiple sclerosis lesions and asymptomatic white-matter lesions, by the presence or absence of a detectable central blood vessel. The aim of the present work is to improve the technique by increasing the sensitivity to veins at both 3 T and 7 T, and to assess the benefit of ultra-high-field imaging. Signal-to-noise ratio (SNR) measurements and simulations are used to compare the sensitivity of magnitude T{sub 2}{sup *}-weighted and susceptibility-weighted images for the detection of small veins (<1 pixel in diameter), both with and without the use of gadolinium. The simulations are used to predict the optimal scanning parameters in order to increase the sensitivity to these veins at both field strengths, and to reduce the inherent dependence on vessel orientation. The sensitivities of the sequences at both field strengths are compared, theoretically and experimentally, in order to quantify the benefit of imaging at ultra-high-field. Subjects with multiple sclerosis (MS) are scanned at both field strengths, using the optimised sequence parameters, as well as those used in previously published work, and the optimisation is shown to improve the detection of veins within lesions.

  12. Optimisation of T2*-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T

    International Nuclear Information System (INIS)

    Dixon, Jennifer Elizabeth; Simpson, Ashley; Mistry, Niraj; Evangelou, Nikos; Morris, Peter Gordon

    2013-01-01

    T 2 * -weighted magnetic resonance imaging at 7 T has recently been shown to allow differentiation between white-matter multiple sclerosis lesions and asymptomatic white-matter lesions, by the presence or absence of a detectable central blood vessel. The aim of the present work is to improve the technique by increasing the sensitivity to veins at both 3 T and 7 T, and to assess the benefit of ultra-high-field imaging. Signal-to-noise ratio (SNR) measurements and simulations are used to compare the sensitivity of magnitude T 2 * -weighted and susceptibility-weighted images for the detection of small veins (<1 pixel in diameter), both with and without the use of gadolinium. The simulations are used to predict the optimal scanning parameters in order to increase the sensitivity to these veins at both field strengths, and to reduce the inherent dependence on vessel orientation. The sensitivities of the sequences at both field strengths are compared, theoretically and experimentally, in order to quantify the benefit of imaging at ultra-high-field. Subjects with multiple sclerosis (MS) are scanned at both field strengths, using the optimised sequence parameters, as well as those used in previously published work, and the optimisation is shown to improve the detection of veins within lesions

  13. [A surgical case of mesial temporal lobe epilepsy associated with hippocampal sclerosis and traumatic neocortical lesion].

    Science.gov (United States)

    Kitazawa, Yu; Jin, Kazutaka; Iwasaki, Masaki; Suzuki, Hiroyoshi; Tanaka, Fumiaki; Nakasato, Nobukazu

    2017-11-25

    A 26-year-old right-handed woman, with a history of left temporal lobe contusion caused by a fall at the age of 9 months, started to have complex partial seizures with oral automatism at the age of 7 years. The seizures occurred once or twice a month despite combination therapy with several antiepileptic agents. Her history and imaging studies suggested the diagnosis of epilepsy arising from traumatic neocortical temporal lesion. Comprehensive assessment including long-term video EEG monitoring, MRI, FDG-PET, MEG, and neuropsychological evaluation was performed at the age of 26 years. The diagnosis was left mesial temporal lobe epilepsy associated with hippocampal atrophy and traumatic temporal cortical lesion. The patient was readmitted for surgical treatment at the age of 27 years. Intracranial EEG monitoring showed that ictal discharges started in the left hippocampus and spread to the traumatic lesion in the left posterior superior temporal gyrus 10 seconds after the onset. This case could not be classified as dual pathology exactly, because the traumatic left temporal cortical lesion did not show independent epileptogenicity. However, the traumatic lesion was highly likely to be the source of the epileptogenicity, and she had right hemispheric dominance for language and functional deterioration in the whole temporal cortex. Therefore, left amygdalo-hippocampectomy and left temporal lobectomy including the traumatic lesion were performed according to the diagnosis of dual pathology. Subsequently, she remained seizure-free for 3 years. Comprehensive assessment of seizure semiology, neurophysiology, neuroradiology, and neuropsychology is important to determine the optimum therapeutic strategies for drug-resistant epilepsy.

  14. A soft kinetic data structure for lesion border detection.

    Science.gov (United States)

    Kockara, Sinan; Mete, Mutlu; Yip, Vincent; Lee, Brendan; Aydin, Kemal

    2010-06-15

    The medical imaging and image processing techniques, ranging from microscopic to macroscopic, has become one of the main components of diagnostic procedures to assist dermatologists in their medical decision-making processes. Computer-aided segmentation and border detection on dermoscopic images is one of the core components of diagnostic procedures and therapeutic interventions for skin cancer. Automated assessment tools for dermoscopic images have become an important research field mainly because of inter- and intra-observer variations in human interpretations. In this study, a novel approach-graph spanner-for automatic border detection in dermoscopic images is proposed. In this approach, a proximity graph representation of dermoscopic images in order to detect regions and borders in skin lesion is presented. Graph spanner approach is examined on a set of 100 dermoscopic images whose manually drawn borders by a dermatologist are used as the ground truth. Error rates, false positives and false negatives along with true positives and true negatives are quantified by digitally comparing results with manually determined borders from a dermatologist. The results show that the highest precision and recall rates obtained to determine lesion boundaries are 100%. However, accuracy of assessment averages out at 97.72% and borders errors' mean is 2.28% for whole dataset.

  15. Is 3D MPRAGE better than the combination DIR/PSIR for cortical lesion detection at 3T MRI?

    Science.gov (United States)

    Nelson, Flavia; Poonawalla, Aziz; Datta, Sushmita; Wolinsky, Jerry; Narayana, Ponnada

    2014-03-01

    Based on the application of newer magnetic resonance imaging (MRI) acquisition sequences, the detection of cortical lesions (CL) in multiple sclerosis (MS) has significantly improved. Double inversion recovery (DIR) at 3T has increased the detection sensitivity and classification specificity when combined with phase sensitive inversion recovery (PSIR). Previous findings with 3D magnetization prepared rapid acquisition with gradient echo (MPRAGE) sequences, showed improved classification specificity of purely intracortical (IC) and mixed (MX) lesions, compared to the classification based on DIR/PSIR. Direct comparison between the detection of CL by 3D MPRAGE and by DIR/PSIR at 3T has not been evaluated. Eleven subjects were imaged on a 3T magnet. DIR/PSIR and 3D MPRAGE images were reviewed independently. Each image set was reviewed twice; only lesions detected on both sessions were scored. Review time per scan was ~5min for DIR/PSIR and ~15min for 3D MPRAGE. We identified 141 CL (62 IC+79 MX) based on DIR/PSIR images vs. 93 (38 IC+55 MX) based on MPRAGE from all eleven patients. MPRAGE under-detected the number of CL in seven cases and over-detected the number of CL in three, only one case had the same number of CL on both sets of images. Combination DIR/PSIR at 3T is superior to 3D MPRAGE for detection of cortical gray matter lesions in MS. The contrast-to-noise ratio of CL appears to be inferior on the MPRAGE images relative to DIR/PSIR. © 2013 Published by Elsevier B.V.

  16. Automatic detection of breast lesions with MIBI-Tc99m scintimammography using a novelty filter

    International Nuclear Information System (INIS)

    Costa, M.; Moura, L.

    1996-01-01

    An automatic method for detecting breast lesion in scintimammography is described. It is reported that the proposed method not only detects lesions but also classifies them as benign or malignant. The detection method makes use of Kohonen's novelty filter and the classification method is obtained by the analysis of an identified lesion mean profile. The method was able to detect all lesions presented in the scintimammogram and to correctly classify 16 out of 17 malignant lesions and 15 out of 17 benign lesions. The sensitivity of the method was 94,12% and specificity was 88,24%

  17. Reporting and management of breast lesions detected using MRI

    International Nuclear Information System (INIS)

    Dall, B.J.G.; Vinnicombe, S.; Gilbert, F.J.

    2011-01-01

    Magnetic resonance imaging (MRI) is the most accurate technique for diagnosing and delineating the extent of both invasive and in-situ breast cancer and is increasingly being used as part of the preoperative work-up to assess the local extent of disease. It is proving invaluable in providing information that allows successful single-stage surgery. An inevitable consequence of the high sensitivity of MRI is that it will identify additional lesions that may or may not represent significant extra disease. This may complicate and delay the preoperative process. This paper outlines a strategy for managing MRI-detected lesions to optimize the benefits of breast MRI as a local staging tool while minimizing the false-positive diagnoses. It discusses the importance of good technique to reduce the number of indeterminate lesions. Methods to refine the patient pathway to minimize delays are discussed. The format of MRI reporting is discussed in detail as is the usefulness of discussion of cases at multidisciplinary meetings. Illustrative cases are used to clarify the points made.

  18. ADvanced IMage Algebra (ADIMA): a novel method for depicting multiple sclerosis lesion heterogeneity, as demonstrated by quantitative MRI.

    Science.gov (United States)

    Yiannakas, Marios C; Tozer, Daniel J; Schmierer, Klaus; Chard, Declan T; Anderson, Valerie M; Altmann, Daniel R; Miller, David H; Wheeler-Kingshott, Claudia A M

    2013-05-01

    There are modest correlations between multiple sclerosis (MS) disability and white matter lesion (WML) volumes, as measured by T2-weighted (T2w) magnetic resonance imaging (MRI) scans (T2-WML). This may partly reflect pathological heterogeneity in WMLs, which is not apparent on T2w scans. To determine if ADvanced IMage Algebra (ADIMA), a novel MRI post-processing method, can reveal WML heterogeneity from proton-density weighted (PDw) and T2w images. We obtained conventional PDw and T2w images from 10 patients with relapsing-remitting MS (RRMS) and ADIMA images were calculated from these. We classified all WML into bright (ADIMA-b) and dark (ADIMA-d) sub-regions, which were segmented. We obtained conventional T2-WML and T1-WML volumes for comparison, as well as the following quantitative magnetic resonance parameters: magnetisation transfer ratio (MTR), T1 and T2. Also, we assessed the reproducibility of the segmentation for ADIMA-b, ADIMA-d and T2-WML. Our study's ADIMA-derived volumes correlated with conventional lesion volumes (p < 0.05). ADIMA-b exhibited higher T1 and T2, and lower MTR than the T2-WML (p < 0.001). Despite the similarity in T1 values between ADIMA-b and T1-WML, these regions were only partly overlapping with each other. ADIMA-d exhibited quantitative characteristics similar to T2-WML; however, they were only partly overlapping. Mean intra- and inter-observer coefficients of variation for ADIMA-b, ADIMA-d and T2-WML volumes were all < 6 % and < 10 %, respectively. ADIMA enabled the simple classification of WML into two groups having different quantitative magnetic resonance properties, which can be reproducibly distinguished.

  19. Distinct pattern of lesion distribution in multiple sclerosis is associated with different circulating T-helper and helper-like innate lymphoid cell subsets.

    Science.gov (United States)

    Gross, Catharina C; Schulte-Mecklenbeck, Andreas; Hanning, Uta; Posevitz-Fejfár, Anita; Korsukewitz, Catharina; Schwab, Nicholas; Meuth, Sven G; Wiendl, Heinz; Klotz, Luisa

    2017-06-01

    Distinct lesion topography in relapsing-remitting multiple sclerosis (RRMS) might be due to different antigen presentation and/or trafficking routes of immune cells into the central nervous system (CNS). To investigate whether distinct lesion patterns in multiple sclerosis (MS) might be associated with a predominance of distinct circulating T-helper cell subset as well as their innate counterparts. Flow cytometric analysis of lymphocytes derived from the peripheral blood of patients with exclusively cerebral (n = 20) or predominantly spinal (n = 12) disease manifestation. Patients with exclusively cerebral or preferential spinal lesion manifestation were associated with increased proportions of circulating granulocyte-macrophage colony-stimulating factor (GM-CSF) producing T H 1 cells or interleukin (IL)-17-producing T H 17 cells, respectively. In contrast, proportions of peripheral IL-17/IL-22-producing lymphoid tissue inducer (LTi), the innate counterpart of T H 17 cells, were enhanced in RRMS patients with exclusively cerebral lesion topography. Distinct T-helper and T-helper-like innate lymphoid cell (ILC) subsets are associated with different lesion topography in RRMS.

  20. Lack of magnetic resonance imaging lesion activity as a treatment target in multiple sclerosis: An evaluation using electronically collected outcomes.

    Science.gov (United States)

    Conway, Devon S; Thompson, Nicolas R; Cohen, Jeffrey A

    2016-09-01

    The appropriate treatment target in multiple sclerosis (MS) is unclear. Lack of magnetic resonance imaging (MRI) lesion activity, a component of the no evidence of disease activity concept, has been proposed as a treatment target in MS. We used our MS database to investigate whether aggressively pursuing MRI stability by changing disease modifying therapy (DMT) when MRI activity is observed leads to better clinical and imaging outcomes. The Knowledge Program (KP) is a database linked to our electronic medical record allowing capture of patient and clinician reported outcomes. Through KP query and chart review, we identified all relapsing-remitting MS patients visiting between 1 January 2008 and 31 December 2014 with active MRIs despite DMT. Propensity modeling based on demographic and disease characteristics was used to match DMT switchers to non-switchers. KP and MRI outcomes were compared 18 months after the active MRI using mixed-effects linear regression models. We identified 417 patients who met criteria for our analysis. After propensity matching, 78 switchers and 91 non-switchers were analyzed. There was no difference in clinical or radiologic outcomes between these groups at 18 months. We did not find a short-term benefit of changing DMT to pursue MRI stability. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Daclizumab high-yield process reduced the evolution of new gadolinium-enhancing lesions to T1 black holes in patients with relapsing-remitting multiple sclerosis.

    Science.gov (United States)

    Radue, E-W; Sprenger, T; Vollmer, T; Giovannoni, G; Gold, R; Havrdova, E; Selmaj, K; Stefoski, D; You, X; Elkins, J

    2016-02-01

    In the SELECT study, treatment with daclizumab high-yield process (DAC HYP) versus placebo reduced the frequency of gadolinium-enhancing (Gd(+) ) lesions in patients with relapsing-remitting multiple sclerosis (RRMS). The objective of this post hoc analysis of SELECT was to evaluate the effect of DAC HYP on the evolution of new Gd(+) lesions to T1 hypointense lesions (T1 black holes). SELECT was a randomized double-blind study of subcutaneous DAC HYP 150 or 300 mg or placebo every 4 weeks. Magnetic resonance imaging (MRI) scans were performed at baseline and weeks 24, 36 and 52 in all patients and monthly between weeks 4 and 20 in a subset of patients. MRI scans were evaluated for new Gd(+) lesions that evolved to T1 black holes at week 52. Data for the DAC HYP groups were pooled for analysis. Daclizumab high-yield process reduced the number of new Gd(+) lesions present at week 24 (P = 0.005) or between weeks 4 and 20 (P = 0.014) that evolved into T1 black holes at week 52 versus placebo. DAC HYP treatment also reduced the percentage of patients with Gd(+) lesions evolving to T1 black holes versus placebo. Treatment with DAC HYP reduced the evolution of Gd(+) lesions to T1 black holes versus placebo, suggesting that inflammatory lesions that evolved during DAC HYP treatment are less destructive than those evolving during placebo treatment. © 2016 EAN.

  2. Comparison of sensitivity of magnetic resonance imaging and evoked potentials in the detection of brainstem involvement in multiple sclerosis

    International Nuclear Information System (INIS)

    Comi, G.; Martinelli, V.; Medaglini, S.; Locatelli, T.; Magnani, G.; Poggi, A.; Triulzi, F.

    1988-01-01

    A comparison was made of the sensitivity of magnetic resonance imaging and the combined use of Brainstem Auditory Evoked Potential and Median Somatosensory Evoked Potential in the detection of brainstem dysfunction in 54 multiple sclerosis patients. 10 refs.; 2 tabs

  3. The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques.

    Science.gov (United States)

    Farshidfar, Z; Faeghi, F; Haghighatkhah, H R; Abdolmohammadi, J

    2017-09-01

    Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don't have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is evaluating the efficiency of different MRI sequences in order to better detection of MS plaques. In this cross-sectional study which was performed at Shohada-E Tajrish in Tehran - Iran hospital between October, 2011 to April, 2012, included 20 patients who suspected to MS disease were selected by the method of random sampling and underwent routine brain Pulse sequences (Axial T2w, Axial T1w, Coronal T2w, Sagittal T1w, Axial FLAIR) by Siemens, Avanto, 1.5 Tesla system. If any lesion which is suspected to the MS disease was observed, additional sequences such as: Sagittal FLAIR Fat Sat, Sagittal PDw-fat Sat, Sagittal PDw-water sat was also performed. This study was performed in about 52 lesions and the results in more than 19 lesions showed that, for the Subcortical and Infratentorial areas, PDWw sequence with fat suppression is the best choice, And in nearly 33 plaques located in Periventricular area, FLAIR Fat Sat was the most effective sequence than both PDw fat and water suppression pulse sequences. Although large plaques may visible in all images, but important problem in patients with suspected MS is screening the tiny MS plaques. This study showed that for revealing the MS plaques located in the Subcortical and Infratentorial areas, PDw-fat sat is the most effective sequence, and for MS plaques in the periventricular area, FLAIR fat Sat is the best choice.

  4. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  5. The corticospinal tract lesion of amyotrophic lateral sclerosis. Magnetic resonance imaging of the spinal cord

    International Nuclear Information System (INIS)

    Terao, Shin-ichi; Sobue, Gen; Mitsuma, Terunori; Yasuda, Takeshi; Kachi, Teruhiko.

    1994-01-01

    Magnetic resonance imaging by gradient echo method demonstrated lesions of the lateral corticospinal tract at cervical cord levels in three ALS patients. Patient 1 was a 43-year-old woman with common from of ALS. She developed right-side predominant pyramidal signs, and right-side predominant prolongation of central motor conduction time. MRI showed hypersignal intensity areas in the dorsal region of the lateral column at the 4th and 5th cervical segments with right-side predominacy. Patient 2 was a 65-year-old man with pseudopolyneuritic from of ALS, who showed lower motor neuron signs without a pyramidal sign. MRI of the 3rd and 4th cervical cord segments demonstrated bilateral hypersignal intensity areas in the dorsal part of the lateral column. Patient 3 was a 62-year-old man with common form of ALS, who showed marked bilateral pyramidal signs with Babinski's sign. MRI of the 5th cervical spinal cord segment demonstrated bilateral hypersignal intensity areas in the dorsolateral column. MR images of the spinal cord thus obtained corresponded well to the postmortem confirmed degeneration of the spinal corticospinal tract. MRI of the spinal cord performed by gradient echo method would provide additional information on the upper motor neuron involvement in ALS. (author)

  6. The corticospinal tract lesion of amyotrophic lateral sclerosis. Magnetic resonance imaging of the spinal cord

    Energy Technology Data Exchange (ETDEWEB)

    Terao, Shin-ichi; Sobue, Gen; Mitsuma, Terunori (Aichi Medical Univ., Nagakute (Japan)); Yasuda, Takeshi; Kachi, Teruhiko

    1994-09-01

    Magnetic resonance imaging by gradient echo method demonstrated lesions of the lateral corticospinal tract at cervical cord levels in three ALS patients. Patient 1 was a 43-year-old woman with common from of ALS. She developed right-side predominant pyramidal signs, and right-side predominant prolongation of central motor conduction time. MRI showed hypersignal intensity areas in the dorsal region of the lateral column at the 4th and 5th cervical segments with right-side predominacy. Patient 2 was a 65-year-old man with pseudopolyneuritic from of ALS, who showed lower motor neuron signs without a pyramidal sign. MRI of the 3rd and 4th cervical cord segments demonstrated bilateral hypersignal intensity areas in the dorsal part of the lateral column. Patient 3 was a 62-year-old man with common form of ALS, who showed marked bilateral pyramidal signs with Babinski's sign. MRI of the 5th cervical spinal cord segment demonstrated bilateral hypersignal intensity areas in the dorsolateral column. MR images of the spinal cord thus obtained corresponded well to the postmortem confirmed degeneration of the spinal corticospinal tract. MRI of the spinal cord performed by gradient echo method would provide additional information on the upper motor neuron involvement in ALS. (author).

  7. Phase sensitive reconstruction of T1-weighted inversion recovery in the evaluation of the cervical cord lesions in multiple Sclerosis; is it similarly eligible in 1.5 T magnet fields?

    Science.gov (United States)

    Shayganfar, A; Sarrami, A H; Fathi, S; Shaygannejad, V; Shamsian, S

    2018-04-22

    In primary studies with 3 T Magnets, phase sensitive reconstruction of T1-weighted inversion recovery (PSIR) have showed ability to depict the cervical multiple sclerosis (MS) lesions some of which may not be detected by short tau inversion recovery (STIR). Regarding to more availability of 1.5 T MRI, this study was designed to evaluate the eligibility of PSIR in 1.5 T for detection of spinal cord MS lesions. In a study between September 2016 till March 2017 the patients with proven diagnosis of MS enrolled to the study. The standard protocol (sagittal STIR and T2W FSE and axial T2W FSE) as well as sagittal PSIR sequences were performed using a 1.5 T magnet. The images were studied and the lesions were localized and recorded as sharp or faint on each sequence. Of 25 patients (22 females and 3 males, with mean age of 33.5 ± 9.8 years and mean disease duration of 5.4 ± 3.9 years) 69 lesions in STIR, 53 lesions in T2W FSE, 47 lesions in Magnitude reconstruction of PSIR (Magnitude), and 30 lesions in phase sensitive (real) reconstruction PSIR were detected. A Wilcoxon signed-rank test showed STIR has a statistically significant higher detection rate of the plaques rather than other three sequences. (STIR and T2W FSE, Z = -4.000, p definition of the plaques rather than other three sequences. This study shows that in the setting of a 1.5 T magnet field, STIR significantly has a superiority over both of the PSIR reconstructions (i.e. real and magnitude) for the detection as well as the boundary definition of the cervical cord lesions of MS. These results have a good relevance to clinical practice by using MRI scanners and sequences routinely available, however, it is discrepant with other reports performed by 3 T Magnet fields. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Impairment of visuospatial/visuoconstructional skills in multiple sclerosis patients: the correlation with regional lesion load and subcortical atrophy.

    Science.gov (United States)

    Marasescu, R; Cerezo Garcia, M; Aladro Benito, Y

    2016-04-01

    About 20% to 26% of patients with multiple sclerosis (MS) show alterations in visuospatial/visuoconstructive (VS-VC) skills even though temporo-parieto-occipital impairment is a frequent finding in magnetic resonance imaging. No studies have specifically analysed the relationship between these functions and lesion volume (LV) in these specific brain areas. To evaluate the relationship between VS-VC impairment and magnetic resonance imaging temporo-parieto-occipital LV with subcortical atrophy in patients with MS. Of 100 MS patients undergoing a routine neuropsychological evaluation, 21 were selected because they displayed VS-VC impairments in the following tests: Incomplete picture, Block design (WAIS-III), and Rey-Osterrieth complex figure test. We also selected 13 MS patients without cognitive impairment (control group). Regional LV was measured in FLAIR and T1-weighted images using a semiautomated method; subcortical atrophy was measured by bicaudate ratio and third ventricle width. Partial correlations (controlling for age and years of school) and linear regression analysis were employed to analyse correlations between magnetic resonance imaging parameters and cognitive performance. All measures of LV and brain atrophy were significantly higher in patients with cognitive impairment. Regional LV, bicaudate ratio, and third ventricle width are significantly and inversely correlated with cognitive performance; the strongest correlation was between third ventricle width and VC performance (Block design: P=.001; Rey-Osterrieth complex figure: P<.000). In the multivariate analysis, third ventricle width only had a significant effect on performance of VC tasks (Block design: P=.000; Rey-Osterrieth complex figure: P=.000), and regional FLAIR VL was linked to the VS task (Incomplete picture; P=.002). Measures of subcortical atrophy explain the variations in performance on visuocostructive tasks, and regional FLAIR VL measures are linked to VS tasks. Copyright © 2015

  9. Optimal reconstructed section thickness for the detection of liver lesions with multidetector CT

    International Nuclear Information System (INIS)

    Soo, G.; Lau, K.K.; Yik, T.; Kutschera, P.

    2010-01-01

    Aim: To evaluate the impact of different reconstructed section thicknesses on liver lesion detection using multidetector computed tomography (CT). Methods: Fifty-three patients were examined using a 16-section CT machine with axial reconstructions provided at 2.5, 5, 7.5, and 10 mm section thicknesses. Images of different reconstructed section thicknesses from different patients were presented in random order to three independent, blinded radiologists for review at multiple sessions. All images were then reviewed by three radiologists in a common session. Consensus was reached following review of the previous interpretation results and results of follow-up imaging regarding the number of true liver lesions (n = 101) for comparison. Results: Mean detection rates were as follows: 93/101 lesions detected with the 2.5 mm section thickness, 98/101 lesions detected at the 5 mm section thickness, 78/101 lesions detected at the 7.5 mm section thickness, and 54/101 lesions detected at the 10 mm section thickness. Lesions missed at the 2.5 mm section thickness were due to masking by image noise. There was particular difficulty detecting subcapsular lesions and lesions adjacent to fissures or the gall bladder at the 7.5 mm and 10 mm section thicknesses. Conclusion: The optimal reconstructed section thickness for lesion detection in the liver was 5 mm.

  10. [Total brain T2-hyperintense lesion-volume and the axonal damage in the normal-appearing white matter of brainstem in early lapsing-remitting multiple sclerosis].

    Science.gov (United States)

    Pascual-Lozano, A M; Martínez-Bisbal, M C; Boscá-Blasco, I; Valero-Merino, C; Coret-Ferrer, F; Martí-Bonmatí, L; Martínez-Granados, B; Celda, B; Casanova-Estruch, B

    To evaluate the relationship between the total brain T2-hyperintense lesion volume (TBT2LV) and the axonal damage in the normal-appearing white matter of brainstem measured by 1H-MRS in a group of early relapsing-remitting multiple sclerosis patients. 40 relapsing-remitting multiple sclerosis patients and ten sex- and age-matched healthy subjects were prospectively studied for two years. T2-weighted MR and 1H-MRS imaging were acquired at time of recruitment and at year two. The TBT2LV was calculated with a semiautomatic program; N-acetylaspartate (NAA), creatine (Cr) and choline (Cho) resonances areas were integrated with jMRUI program and the ratios were calculated for four volume elements that represented the brainstem. At basal study we obtained an axonal loss (as a decrement of NAA/ Cho ratio) in the group of patients compared with controls (p = 0.017); this axonal loss increased at the second year of the follow-up for patients (NAA/Cho decrease, p = 0.004, and NAA/Cr decrease, p = 0.002) meanwhile control subjects had no significant metabolic changes. Higher lesion load was correlated with a poor clinical outcome, being the correlation between the basal TBT2LV and the Expanded Disability Status Scale at second year (r = 0.299; p = 0.05). Besides, axonal loss was not homogeneous for all multiple sclerosis patients, being stronger in the subgroup of patients with high basal TBT2LV (p = 0.043; ANOVA). Our data suggest that axonal damage is early in multiple sclerosis and higher in patients high basal TBT2LV, suggesting a possible relationship between these two phenomena.

  11. Detection and quantification of regional cortical gray matter damage in multiple sclerosis utilizing gradient echo MRI

    Directory of Open Access Journals (Sweden)

    Jie Wen

    2015-01-01

    Full Text Available Cortical gray matter (GM damage is now widely recognized in multiple sclerosis (MS. The standard MRI does not reliably detect cortical GM lesions, although cortical volume loss can be measured. In this study, we demonstrate that the gradient echo MRI can reliably and quantitatively assess cortical GM damage in MS patients using standard clinical scanners. High resolution multi-gradient echo MRI was used for regional mapping of tissue-specific MRI signal transverse relaxation rate values (R2* in 10 each relapsing–remitting, primary-progressive and secondary-progressive MS subjects. A voxel spread function method was used to correct artifacts induced by background field gradients. R2* values from healthy controls (HCs of varying ages were obtained to establish baseline data and calculate ΔR2* values – age-adjusted differences between MS patients and HC. Thickness of cortical regions was also measured in all subjects. In cortical regions, ΔR2* values of MS patients were also adjusted for changes in cortical thickness. Symbol digit modalities (SDMT and paced auditory serial addition (PASAT neurocognitive tests, as well as Expanded Disability Status Score, 25-foot timed walk and nine-hole peg test results were also obtained on all MS subjects. We found that ΔR2* values were lower in multiple cortical GM and normal appearing white matter (NAWM regions in MS compared with HC. ΔR2* values of global cortical GM and several specific cortical regions showed significant (p < 0.05 correlations with SDMT and PASAT scores, and showed better correlations than volumetric measures of the same regions. Neurological tests not focused on cognition (Expanded Disability Status Score, 25-foot timed walk and nine-hole peg tests showed no correlation with cortical GM ΔR2* values. The technique presented here is robust and reproducible. It requires less than 10 min and can be implemented on any MRI scanner. Our results show that quantitative tissue-specific R2

  12. Brain lesions in congenital nystagmus as detected by computed tomography

    International Nuclear Information System (INIS)

    Lo, Chin-Ying

    1982-01-01

    Computed tomography (CT) was performed in a series of 60 cases with congenital nystagmus. The type of nystagmus was pendular in 20 and jerky in 40 cases. The age ranged from 3 months to 13 years. Abnormal CT findings of the central nervous system were detected in 31 cases (52%). There were 5 major CT findings: midline anomalies, cortical atrophy, ventricular dilatation, brain stem atrophy and low density area. The midline anomalies involved cavum septi pellucidi, cavum Vergae, cavum veli interpositi and partial agenesis of corpus callosum. The abnormal CT findings were more prominent in pendular type than in jerky type. The incidence of congenital nystagmus and positive CT findings were the same in the first and the second birth. There was a history of abnormalities during the prenatal or perinatal period in 28 out of the 60 cases (47%). This feature seemed to play a significant role in the occurrence of congenital nystagmus. The observed organic lesions in the central nervous system by CT would contribute to the elucidation of pathomechanism of congenital nystagmus. (author)

  13. Lesions inflammatory activity quantification in multiple sclerosis using [{sup 11}C]-(R)-PK11195 PET brain images; Quantificacao da atividade inflamatoria em lesoes na esclerose multipla usando imagens PET cerebrais com [{sup 11}C]-(R)-PK11195

    Energy Technology Data Exchange (ETDEWEB)

    Schuck, Phelipi N.; Narciso, Lucas D.L.; Dartora, Caroline M.; Silva, Ana M. Marques da, E-mail: phelipi.schuck@acad.pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Nucleo de Pesquisa em Imagens Medicas

    2016-07-01

    The criteria for multiple sclerosis (MS) diagnosis include the presence of lesions in brain regions called black holes (BH), characterized by low signal on magnetic resonance imaging T1-weighted. Studies suggest that lesions in MS, if there is an inflammatory process, can be detected in PET imaging with [{sup 11}C]- (R)-PK11195. The aim of this study is to investigate the uptake of [{sup 11}C]-(R)-PK11195 in BH in PET images, searching for inflammation activity in lesions and neighborhoods. Semiquantitative methods of SUV and uptake normalization were applied to PET images, in different time intervals, acquired from 8 MS patients and 5 healthy controls. Higher uptake was identified in BH and its edges, when compared with health controls white matter, when the SUV method is applied (p < 0,01, 40 to 60 min). When uptake normalization method is applied, smaller uptake in black holes and its your edges is observed, when compared with white matter apparently healthy (p < 0,01, 0 to 60 min). (author)

  14. Persistent activation of microglia is associated with neuronal dysfunction of callosal projecting pathways and multiple sclerosis-like lesions in relapsing--remitting experimental autoimmune encephalomyelitis

    DEFF Research Database (Denmark)

    Rasmussen, Stine; Wang, Yue; Kivisäkk, Pia

    2007-01-01

    callosal projecting neurons. There was significant impairment of retrograde labeling of NeuN-positive callosal projecting neurons and reduction in the labelling of their transcallosal axons. These data demonstrate a novel paradigm of cortical and callosal neuropathology in a mouse model of MS, perpetuated......Cortical pathology, callosal atrophy and axonal loss are substrates of progression in multiple sclerosis (MS). Here we describe cortical, periventricular subcortical lesions and callosal demyelination in relapsing-remitting experimental autoimmune encephalomyelitis in SJL mice that are similar...... to lesions found in MS. Unlike the T-cell infiltrates that peak during acute disease, we found that microglia activation persists through the chronic disease phase. Microglia activation correlated with abnormal phosphorylation of neurofilaments in the cortex and stripping of synaptic proteins in cortical...

  15. Characteristics, Detection Methods and Treatment of Questionable Occlusal Carious Lesions

    DEFF Research Database (Denmark)

    Makhija, S.K.; Gilbert, G.H.; Funkhouser, E.

    2014-01-01

    . The objective of this report has been to quantify the characteristics of these common lesions, the diagnostic aids used and the treatment of QOC. A total of 82 dentist and hygienist practitioner-investigators from the USA and Denmark in the National Dental Practice-Based Research Network participated. When...... consenting patients presented with a QOC, information was recorded about the patient, tooth, lesion and treatments. A total of 2,603 QOC from 1,732 patients were analyzed. The lesions were usually associated with a fissure, on molars, and varied from yellow to black in color. Half presented with a chalky...... luster and had a rough surface when examined with an explorer. There was an association between color and luster: 10% were chalky-light, 47% were shiny-dark and 42% were mixtures. A higher proportion of chalky than of shiny lesions were light (22 vs. 9%; p color were less common...

  16. Evaluation of the Significance of Incidental Breast Lesions Detected by Chest CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyun; Chang, Yun Woo; Hwang, Jung Hwa; Kim, Hyung Hwan; Lee, Eun Hye; Yang, Seung Boo

    2013-01-01

    To evaluate the significance of incidentally detected breast lesions on a chest CT scan. Thirty-six incidental breast lesions in 26 patients were detected on a chest CT scan and were correlated with breast sonography, retrospectively. Among them, twenty-four breast lesions in 20 patients that were correlated with chest CT and sonography were available to pathology or follow up sonography. The CT findings were compared with sonographic findings according to the pathologic results. Incidentally detected breast lesions on a chest CT scan were correlated with sonography in 86% (31/36). Among 24 lesions that were available to pathology or follow up sonography, seven (29.2%) lesions were malignant and 17 (70.8%) lesions were benign. CT revealed a significant difference between benign and malignant lesions in terms of shape and margin (p = 0.007; p = 0.008, respectively). The CT findings were well correlated with sonographic findings in shape and margin (p = 0.001, respectively). Incidentally detected breast lesions on chest CT can be correlated with sonography. An irregular shape or a non-circumscribed margin of breast lesions on a CT scan can be considered as a suggestive sign of malignancy.

  17. Intestinal lesions in pediatric Crohn disease: comparative detectability among pulse sequences at MR enterography

    International Nuclear Information System (INIS)

    Sohn, Beomseok; Kim, Myung-Joon; Lee, Mi-Jung; Koh, Hong; Han, Kyung Hwa

    2014-01-01

    Variable sequences can be used in MR enterography, and no consensus exists for the best protocol in children with Crohn disease. To compare the lesion detectability of various MR enterography sequences and to correlate the findings of these sequences with the Pediatric Crohn's Disease Activity Index (PCDAI) in children with Crohn disease. Children with clinically or pathologically confirmed Crohn disease underwent MR enterography, including a single-shot fast spin-echo (SSFSE) sequence, motility imaging (coronal 2-D balanced fast field echo), diffusion-weighted imaging (DWI), and dynamic contrast enhancement imaging (including arterial, portal and delayed phases). The lesion detectability of each sequence was graded 0-2 for each involved bowel segment. The lesion detectability and PCDAI result on different sequences were compared using the weighted least squares method and Student's t-test, respectively. Fifteen children (11 boys, 4 girls, mean age 13.7 ± 1.4 years) with a total of 41 lesions were included in this study. All lesions detected in more than two sequences were visible on the single-shot fast spin-echo (SSFSE) sequence. The relative lesion detection rate was 78.1% on motility imaging, 90.2% on DWI, and 92.7% on arterial, 95.1% on portal and 95.1% on delayed phase imaging. Compared to the SSFSE sequence, motility imaging (P < 0.001) and DWI (P = 0.039) demonstrated lower detectability. The mean PCDAI result in the detected lesions was statistically higher only on dynamic enhancement imaging (P < 0.001). All MR enterography sequences were found to have relatively high lesion detectability in children with Crohn disease, while motility imaging showed the lowest lesion detectability. Lesions detected on dynamic enhancement imaging showed a higher PCDAI result, which suggests that this sequence is specific for active inflammation. (orig.)

  18. An ensemble deep learning based approach for red lesion detection in fundus images.

    Science.gov (United States)

    Orlando, José Ignacio; Prokofyeva, Elena; Del Fresno, Mariana; Blaschko, Matthew B

    2018-01-01

    Diabetic retinopathy (DR) is one of the leading causes of preventable blindness in the world. Its earliest sign are red lesions, a general term that groups both microaneurysms (MAs) and hemorrhages (HEs). In daily clinical practice, these lesions are manually detected by physicians using fundus photographs. However, this task is tedious and time consuming, and requires an intensive effort due to the small size of the lesions and their lack of contrast. Computer-assisted diagnosis of DR based on red lesion detection is being actively explored due to its improvement effects both in clinicians consistency and accuracy. Moreover, it provides comprehensive feedback that is easy to assess by the physicians. Several methods for detecting red lesions have been proposed in the literature, most of them based on characterizing lesion candidates using hand crafted features, and classifying them into true or false positive detections. Deep learning based approaches, by contrast, are scarce in this domain due to the high expense of annotating the lesions manually. In this paper we propose a novel method for red lesion detection based on combining both deep learned and domain knowledge. Features learned by a convolutional neural network (CNN) are augmented by incorporating hand crafted features. Such ensemble vector of descriptors is used afterwards to identify true lesion candidates using a Random Forest classifier. We empirically observed that combining both sources of information significantly improve results with respect to using each approach separately. Furthermore, our method reported the highest performance on a per-lesion basis on DIARETDB1 and e-ophtha, and for screening and need for referral on MESSIDOR compared to a second human expert. Results highlight the fact that integrating manually engineered approaches with deep learned features is relevant to improve results when the networks are trained from lesion-level annotated data. An open source implementation of our

  19. Comparison of AMI-25 enhanced MRI and helical dynamic CT in the detection of hepatic lesions

    International Nuclear Information System (INIS)

    Saitou, Kazuhiro; Matsuda, Hiromichi; Fukushima, Hiroaki; Kanzaki, Hiroshi; Hirose, Takashi; Karizaki, Dai; Abe, Kimihiko; Amino, Saburou

    1994-01-01

    We performed AMI-25 enhanced MRI and helical dynamic CT in 12 cases of hepatic lesions. Nine of these were hepatocellular carcinomas. Two cases were metastatic liver tumors (the primary lesion was gastric in one and the other was gallbladder cancer). One case was suspected to be adenomatous hyperplasia. Thirty-two lesions were detected in T2-weighted SE images before AMI-25 administration, while 46 lesions were detected in AMI-25 enhanced MRI images. In particular, AMI-25 enhanced MRI was superior to plain MRI in lesions less than 10 mm in size. A total of 48 lesions were detected in helical dynamic CT. Although AMI-25 enhanced MRI almost equaled helical dynamic CT in the detection of liver tumors, helical dynamic CT was slightly superior to AMI-25 enhanced MRI in the detection of subphrenic lesions. It was possible to know the hemodynamics in each hepatic lesion by helical dynamic CT. AMI-25 enhanced MRI was useful to know the inclusion of reticuloendothelial system, and that yielded different diagnoses in adenomatous hyperplasia and well differentiated hepatocellular carcinoma. Helical dynamic CT was useful for qualitative diagnosis. Both AMI-25 enhanced MRI and helical dynamic CT contributed to the detection of liver tumor and qualitative diagnosis. (author)

  20. Targeted Ultrasound for MR-Detected Lesions in Breast Cancer Patients

    International Nuclear Information System (INIS)

    Shin, Jung Hee; Han, Boo Kyung; Choe, Yeon Hyeon; Ko, Kyung Ran; Choi, Nami

    2007-01-01

    To investigate the usefulness of targeted ultrasound (US) in the identification of additional suspicious lesions found by magnetic resonance (MR) imaging in breast cancer patients and the changes in treatment based on the identification of the lesions by the use of targeted US. One-hundred forty nine patients who underwent breast MR imaging for a preoperative evaluation of breast cancer between January 2002 and July 2004 were included in the study. We searched all cases for any additional lesions that were found initially by MR imaging and investigated the performance of targeted US in identifying the lesions. We also investigated their pathological outcomes and changes in treatment as a result of lesion identification. Of the 149 patients with breast cancer, additional suspicious lesions were detected with MR imaging in 62 patients (42%). Of the 69 additional lesions found in those 62 patients, 26 (38%) were confirmed as cancers by histology. Thirty-eight lesions in 31 patients were examined with targeted US and were histologically revealed as cancers in 18 (47%), high risk lesions in two (5%), benign lesions in 15 (39%), and unidentified lesions in three (8%). The cancer rate was statistically higher in lesions with a US correlate than in lesions without a US correlate (p = 0.028). Of 31 patients, the surgical plan was altered in 27 (87%). The use of targeted US justified a change in treatment for 22 patients (81%) and misled five patients (19%) into having an unnecessary surgical excision. Targeted US can play a useful role in the evaluation of additional suspicious lesions detected by MR imaging in breast cancer patients, but is limited in lesions without a US correlate

  1. Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Takashi; Urata, Joji [Diagnostic Imaging Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Mitsuzaki, Katsuhiko; Matsuda, Katsuhiko; Kawakami, Megumi [Medical Examination Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Utsunomiya, Daisuke; Yamamura, Sadahiro; Yamashita, Yasuyuki [Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)], e-mail: utsunomi@kumamoto-u.ac.jp

    2012-09-15

    Background: Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. Purpose: To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. Material and Methods: We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Results: Detection sensitivity for flat polyps was 31.3 %, 44.4 %, and 87.5 % for lesions measuring 2-3 mm, 4-5 mm, and {>=}6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6 %, 79.0 %, and 91.7 %. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. Conclusion: CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.

  2. Lesion Detection in CT Images Using Deep Learning Semantic Segmentation Technique

    Science.gov (United States)

    Kalinovsky, A.; Liauchuk, V.; Tarasau, A.

    2017-05-01

    In this paper, the problem of automatic detection of tuberculosis lesion on 3D lung CT images is considered as a benchmark for testing out algorithms based on a modern concept of Deep Learning. For training and testing of the algorithms a domestic dataset of 338 3D CT scans of tuberculosis patients with manually labelled lesions was used. The algorithms which are based on using Deep Convolutional Networks were implemented and applied in three different ways including slice-wise lesion detection in 2D images using semantic segmentation, slice-wise lesion detection in 2D images using sliding window technique as well as straightforward detection of lesions via semantic segmentation in whole 3D CT scans. The algorithms demonstrate superior performance compared to algorithms based on conventional image analysis methods.

  3. Gender differences in multiple sclerosis : induction of estrogen signaling in male and progesterone signaling in female lesions

    NARCIS (Netherlands)

    Luchetti, Sabina; van Eden, Corbert G; Schuurman, Karianne; van Strien, Miriam E; Swaab, Dick F; Huitinga, Inge

    The basis of gender differences in the prevalence and clinical progression of multiple sclerosis (MS) is not understood. Here, we identify gender-specific responses in steroid synthesis and signaling in the brains of MS patients as possible contributors to these differences. We investigated gene

  4. Surgical pathology of epilepsy-associated non-neoplastic cerebral lesions: a brief introduction with special reference to hippocampal sclerosis and focal cortical dysplasia

    Science.gov (United States)

    Miyata, Hajime; Hori, Tomokatsu; Vinters, Harry V.

    2014-01-01

    Among epilepsy-associated non-neoplastic lesions, mesial temporal lobe epilepsy with hippocampal sclerosis (mTLE-HS) and malformation of cortical development (MCD) including focal cortical dysplasia (FCD), are the two most frequent causes of drug-resistant focal epilepsies constituting about 50% of all surgical pathology of epilepsy. Several distinct histological patterns have been historically recognized in both HS and FCD, and several studies have tried to perform clinicopathological correlation; results, however, have been controversial, particularly in terms of postsurgical seizure outcome. Recently, the International League Against Epilepsy constituted a Task Forces of Neuropathology and FCD within the Commission on Diagnostic Methods, to establish an international consensus of histological classification of HS and FCD, respectively, based on agreement with the recognition of the importance of defining a histopathological classification system that reliably has some clinicopathological correlation. Such consensus classifications are likely to facilitate future clinicopathological study. Meanwhile, we reviewed neuropathology of 41 surgical cases of mTLE, and confirmed three type/patterns of HS along with no HS, based on the qualitative evaluation of the distribution and severity of neuronal loss and gliosis within hippocampal formation; i.e., HS type 1 (61%) equivalent to ‘classical’ Ammon’s horn sclerosis, HS type 2 (2%) representing CA1 sclerosis, HS type 3 (17%) equivalent to end folium sclerosis, and no HS (19%). Furthermore we performed a neuropathological comparative study on mTLE-HS and dementia associated HS (d-HS) in elderly, and confirmed that neuropathological features differ between mTLE-HS and d-HS in the distribution of hippocampal neuronal loss and gliosis, morphology of reactive astrocytes and their protein expression, and presence of concomitant neurodegenerative changes particularly Alzheimer type and TDP-43 pathologies. These

  5. Diffusion weighted MR imaging in the diagnosis of multiple sclerosis

    International Nuclear Information System (INIS)

    Hagen, T.; Schweigerer-Schroeter, G.; Wellnitz, J.; Wuerstle, T.

    2000-01-01

    Magnetic resonance (MR) imaging is one of the best methods in diagnosis of multiple sclerosis, particularly in disclosure of active demyelinating lesions. Aim of this study was to compare diffusion weighted imaging and contrast enhancement in the detection of active lesions. A MR study with a contrast enhanced T1-weighted pulse sequence with magnetization transfer presaturation and a diffusion weighted echoplanar pulse sequence (b=1000 s/mm 2 ) was performed in 17 patients (11 women, 6 men) with multiple sclerosis. 29 of 239 lesions showed an increased signal intensity in diffusion weighted imaging, 24 lesions a contrast enhancement, but only 16 lesions were visible in both pulse sequences. In patients with short clinical symptomatology significant more lesions could be detected with diffusion-weighted pulse sequence in comparison to patients with long standing symptomatology showing more lesions with contrast enhancement. Hence it is likely, that both pulse sequences detect different histopathologic changes. The early detection of demyelinating lesions in diffusion weighted imaging is attributed to the extracellular edema, however the contrast enhancement is caused by a blood brain barrier abnormality. It can be expected that diffusion weighted imaging will have a high impact on imaging of multiple sclerosis not only in therapeutic trials, but also in clinical routine. (orig.) [de

  6. Detection of rotator cuff lesions with indirect MR angiography

    International Nuclear Information System (INIS)

    Rudolph, J.; Lorenz, M.; Schroeder, R.; Felix, R.

    2000-01-01

    Purpose: To determine the value of indirect MR arthrography in lesions of the rotator cuff, prospectively versus arthroscopy. Methods: 63 patients with suspected shoulder pathology were examined: Oblique-coronary and axial T 1 w sequences, axial FLASH-2 D sequences, furthermore oblique-coronary T 2 - and PD-weighted sequences were taken. After intravenous administration of 0.1 mmol Gd-DTPA/kilogram body weight and active motion of the shoulder T 1 w sequences were repeated. Signal intensities (SI) inside the tendon were quantitatively measured by the ROI technique (region-of-interest) and the percentual contrast-enhancement CE was calculated. In 32 patients the results were confirmed by surgical follow-up. Results: The mean SI measured in the supraspinous tendon were higher in lesions (degeneration, impingement, partial and total rupture), before as well as after contrast medium, compared to intact findings (p [de

  7. Going With the Flow: An Aid in Detecting and Differentiating Bronchopulmonary Sequestrations and Hybrid Lesions.

    Science.gov (United States)

    Oliver, Edward R; DeBari, Suzanne E; Giannone, Mariann M; Pogoriler, Jennifer E; Johnson, Ann M; Horii, Steven C; Gebb, Juliana S; Howell, Lori J; Adzick, N Scott; Coleman, Beverly G

    2018-02-01

    68 of 73 hybrid lesions. Ultrasound is most accurate for systemic feeding artery detection in bronchopulmonary sequestrations and hybrid lesions and can also type the lesions as intralobar or extralobar when draining veins are evaluated. © 2017 by the American Institute of Ultrasound in Medicine.

  8. A Novel Fuzzy Topological Approach to the Detection of Mammographic Lesions and Quantification of Parenchymal Density

    National Research Council Canada - National Science Library

    Udupa, Jayaram

    2001-01-01

    .... During this project period, the following have been accomplished: The development and validation of a new method of lesion and density detection based on fuzzy connectedness that utilizes the relative strength of connectedness among objects...

  9. Lesion-to-ventricle distance and other risk factors for the persistence of newly formed black holes in relapsing-remitting multiple sclerosis.

    Science.gov (United States)

    Papadopoulou, Athina; Menegola, Milena; Kuhle, Jens; Ramagopalan, Sreeram V; D'Souza, Marcus; Sprenger, Till; Radue, Ernst-Wilhelm; Kappos, Ludwig; Yaldizli, Özgür

    2014-03-01

    Progenitor cells from the subventricular zone (SVZ) of the lateral ventricles are assumed to contribute to remyelination and resolution of black holes (BHs) in multiple sclerosis (MS). This process may depend on the distance between the lesion and the SVZ. The objective of this paper is to investigate the relationship between lesion-to-ventricle (LV) distance and persistence of new BHs. We analysed the magnetic resonance images (MRIs) of 289 relapsing-remitting (RR) MS patients, obtained during a multi-centre, placebo-controlled phase II trial over one year. Overall, 112/289 patients showed 367 new BHs at the beginning of the trial. Of these, 225 were located in 94/112 patients at the level of the lateral ventricles on axial MRIs and included in this analysis. In total, 86/225 (38%) BHs persisted at month 12. LV distance in persistent BHs (PBHs) was not longer than in transient BHs. In fact PBHs tended to be closer to the SVZ than transient BHs. A generalised linear mixed multivariate model adjusted for BHs clustered within a patient and including patient- as well as lesion-specific factors revealed size, ring contrast enhancement, and shorter LV distance as independent predictors for BH persistence. Location of BHs close to the lateral ventricles does not appear to favourably influence the resolution of new BHs in RRMS.

  10. EBI2 Is Highly Expressed in Multiple Sclerosis Lesions and Promotes Early CNS Migration of Encephalitogenic CD4 T Cells

    Directory of Open Access Journals (Sweden)

    Florian Wanke

    2017-01-01

    Full Text Available Arrival of encephalitogenic T cells at inflammatory foci represents a critical step in development of experimental autoimmune encephalomyelitis (EAE, the animal model for multiple sclerosis. EBI2 and its ligand, 7α,25-OHC, direct immune cell localization in secondary lymphoid organs. CH25H and CYP7B1 hydroxylate cholesterol to 7α,25-OHC. During EAE, we found increased expression of CH25H by microglia and CYP7B1 by CNS-infiltrating immune cells elevating the ligand concentration in the CNS. Two critical pro-inflammatory cytokines, interleukin-23 (IL-23 and interleukin-1 beta (IL-1β, maintained expression of EBI2 in differentiating Th17 cells. In line with this, EBI2 enhanced early migration of encephalitogenic T cells into the CNS in a transfer EAE model. Nonetheless, EBI2 was dispensable in active EAE. Human Th17 cells do also express EBI2, and EBI2 expressing cells are abundant within multiple sclerosis (MS white matter lesions. These findings implicate EBI2 as a mediator of CNS autoimmunity and describe mechanistically its contribution to the migration of autoreactive T cells into inflamed organs.

  11. Automated multi-lesion detection for referable diabetic retinopathy in indigenous health care.

    Science.gov (United States)

    Pires, Ramon; Carvalho, Tiago; Spurling, Geoffrey; Goldenstein, Siome; Wainer, Jacques; Luckie, Alan; Jelinek, Herbert F; Rocha, Anderson

    2015-01-01

    Diabetic Retinopathy (DR) is a complication of diabetes mellitus that affects more than one-quarter of the population with diabetes, and can lead to blindness if not discovered in time. An automated screening enables the identification of patients who need further medical attention. This study aimed to classify retinal images of Aboriginal and Torres Strait Islander peoples utilizing an automated computer-based multi-lesion eye screening program for diabetic retinopathy. The multi-lesion classifier was trained on 1,014 images from the São Paulo Eye Hospital and tested on retinal images containing no DR-related lesion, single lesions, or multiple types of lesions from the Inala Aboriginal and Torres Strait Islander health care centre. The automated multi-lesion classifier has the potential to enhance the efficiency of clinical practice delivering diabetic retinopathy screening. Our program does not necessitate image samples for training from any specific ethnic group or population being assessed and is independent of image pre- or post-processing to identify retinal lesions. In this Aboriginal and Torres Strait Islander population, the program achieved 100% sensitivity and 88.9% specificity in identifying bright lesions, while detection of red lesions achieved a sensitivity of 67% and specificity of 95%. When both bright and red lesions were present, 100% sensitivity with 88.9% specificity was obtained. All results obtained with this automated screening program meet WHO standards for diabetic retinopathy screening.

  12. Automated multi-lesion detection for referable diabetic retinopathy in indigenous health care.

    Directory of Open Access Journals (Sweden)

    Ramon Pires

    Full Text Available Diabetic Retinopathy (DR is a complication of diabetes mellitus that affects more than one-quarter of the population with diabetes, and can lead to blindness if not discovered in time. An automated screening enables the identification of patients who need further medical attention. This study aimed to classify retinal images of Aboriginal and Torres Strait Islander peoples utilizing an automated computer-based multi-lesion eye screening program for diabetic retinopathy. The multi-lesion classifier was trained on 1,014 images from the São Paulo Eye Hospital and tested on retinal images containing no DR-related lesion, single lesions, or multiple types of lesions from the Inala Aboriginal and Torres Strait Islander health care centre. The automated multi-lesion classifier has the potential to enhance the efficiency of clinical practice delivering diabetic retinopathy screening. Our program does not necessitate image samples for training from any specific ethnic group or population being assessed and is independent of image pre- or post-processing to identify retinal lesions. In this Aboriginal and Torres Strait Islander population, the program achieved 100% sensitivity and 88.9% specificity in identifying bright lesions, while detection of red lesions achieved a sensitivity of 67% and specificity of 95%. When both bright and red lesions were present, 100% sensitivity with 88.9% specificity was obtained. All results obtained with this automated screening program meet WHO standards for diabetic retinopathy screening.

  13. DETECTION OF CANCEROUS LESION BY UTERINE CERVIX IMAGE SEGMENTATION

    Directory of Open Access Journals (Sweden)

    P. Priya

    2014-02-01

    Full Text Available This paper works at segmentation of lesion observed in cervical cancer, which is the second most common cancer among women worldwide. The purpose of segmentation is to determine the location for a biopsy to be taken for diagnosis. Cervix cancer is a disease in which cancer cells are found in the tissues of the cervix. The acetowhite region is a major indicator of abnormality in the cervix image. This project addresses the problem of segmenting uterine cervix image into different regions. We analyze two algorithms namely Watershed, K-means clustering algorithm, Expectation Maximization (EM Image Segmentation algorithm. These segmentations methods are carried over for the colposcopic uterine cervix image.

  14. Comparisons of lesion detectability in ultrasound images acquired using time-shift compensation and spatial compounding.

    Science.gov (United States)

    Lacefield, James C; Pilkington, Wayne C; Waag, Robert C

    2004-12-01

    The effects of aberration, time-shift compensation, and spatial compounding on the discrimination of positive-contrast lesions in ultrasound b-scan images are investigated using a two-dimensional (2-D) array system and tissue-mimicking phantoms. Images were acquired within an 8.8 x 12-mm2 field of view centered on one of four statistically similar 4-mm diameter spherical lesions. Each lesion was imaged in four planes offset by successive 45 degree rotations about the central scan line. Images of the lesions were acquired using conventional geometric focusing through a water path, geometric focusing through a 35-mm thick distributed aberration phantom, and time-shift compensated transmit and receive focusing through the aberration phantom. The views of each lesion were averaged to form sets of water path, aberrated, and time-shift compensated 4:1 compound images and 16:1 compound images. The contrast ratio and detectability index of each image were computed to assess lesion differentiation. In the presence of aberration representative of breast or abdominal wall tissue, time-shift compensation provided statistically significant improvements of contrast ratio but did not consistently affect the detectability index, and spatial compounding significantly increased the detectability index but did not alter the contrast ratio. Time-shift compensation and spatial compounding thus provide complementary benefits to lesion detection.

  15. Acrolein detection: potential theranostic utility in multiple sclerosis and spinal cord injury.

    Science.gov (United States)

    Tully, Melissa; Zheng, Lingxing; Shi, Riyi

    2014-06-01

    Oxidative stress has been implicated as a major pathological process underlying CNS disease and trauma. More specifically, acrolein, an unsaturated aldehyde, produced by way of lipid peroxidation, has been shown to play a crucial role in initiating and perpetuating detrimental effects associated with multiple sclerosis and spinal cord injury. In light of these findings, quantification of acrolein levels both systemically and locally could allow for the use of acrolein as a biomarker to aid in diagnosis and guide treatment regimens. The three main approaches currently available are acrolein derivatization followed by LC/GC-MS, application of an acrolein antibody and subsequent immunoblotting, and the 3-hydroxypropylmercapturic acid-based method. Of these three strategies, the 3-hydroxypropylmercapturic acid-based method is the least invasive allowing for rapid translation of acrolein detection into a clinical setting.

  16. Spinal focal lesion detection in multiple myeloma using multimodal image features

    Science.gov (United States)

    Fränzle, Andrea; Hillengass, Jens; Bendl, Rolf

    2015-03-01

    Multiple myeloma is a tumor disease in the bone marrow that affects the skeleton systemically, i.e. multiple lesions can occur in different sites in the skeleton. To quantify overall tumor mass for determining degree of disease and for analysis of therapy response, volumetry of all lesions is needed. Since the large amount of lesions in one patient impedes manual segmentation of all lesions, quantification of overall tumor volume is not possible until now. Therefore development of automatic lesion detection and segmentation methods is necessary. Since focal tumors in multiple myeloma show different characteristics in different modalities (changes in bone structure in CT images, hypointensity in T1 weighted MR images and hyperintensity in T2 weighted MR images), multimodal image analysis is necessary for the detection of focal tumors. In this paper a pattern recognition approach is presented that identifies focal lesions in lumbar vertebrae based on features from T1 and T2 weighted MR images. Image voxels within bone are classified using random forests based on plain intensities and intensity value derived features (maximum, minimum, mean, median) in a 5 x 5 neighborhood around a voxel from both T1 and T2 weighted MR images. A test data sample of lesions in 8 lumbar vertebrae from 4 multiple myeloma patients can be classified at an accuracy of 95% (using a leave-one-patient-out test). The approach provides a reasonable delineation of the example lesions. This is an important step towards automatic tumor volume quantification in multiple myeloma.

  17. Differentiation of thyroid lesion detected by FDG PET/CT using SUV ratio

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Kang, Won Jun; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    We investigated the usefulness of SUV ratio to discriminate focal thyroid lesion incidentally detected on 18F-FDG PET/CT (FDG PET) in patients with malignant disease. A total of 2167 subjects with malignant tumor underwent PET/CT for staging. Forty-five of 2167 subjects (2.1%) showed hypermetabolic thyroid lesions on FDG PET. Of 45, 21 lesions were confirmed by pathology (n = 16) or follow up exam (n=5). Seventeen patients had focal FDG uptakes, while 4 patients had diffuse thyroid uptakes. Standardized uptake value (SUV) was measured by drawing region of interest (ROI) on bilateral thyroid lobes and liver. From 21 patients, 12 thyroid lesions were confirmed as malignant lesions and 9 lesions as benign lesions. All of bilateral thyroid FDG uptakes were determined as benign disease such as thyroiditis. From seventeen focal thyroid incidentaloma, FDG PET had 100 % (12/12) of sensitivity and 60 % (3/5) of specificity, retrospectively. Malignant nodules had a significantly higher lesion to liver ratio than those of benign nodules (2.10.9 vs. 1.20.6, p=0.029). With ROC curve, the best cut-off value of lesion to liver was 1.0 with sensitivity of 100% and specificity of 60 % (area under the curve=0.783). The SUV ratio of lesion to contralateral lobe do not have statistical significance to determine malignancy (3.72.1 vs. 2.61.7, p=0.079). This study showed that focal thyroidal FDG uptake detected by FDG PET could be differentiated with best performance by SUV ratio of lesion to liver.

  18. Magnetic resonance in multiple sclerosis

    International Nuclear Information System (INIS)

    Scotti, G.; Caputo, D.; Cazzullo, C.L.

    1986-01-01

    Magnetic Resonance Imaging was performed in more than 200 patients with clinical suspicion or knowledge of Multiple Sclerosis. One hundred and forty-seven (60 males and 87 females) had MR evidence of multiple sclerosis lesions. The MR signal of demyelinating plaques characteristically has prolonged T1 and T2 relaxation times and the T2-weighted spin-echo sequences are generally superior to the T1-weighted images because the lesions are better visualized as areas of increased signal intensity. MR is also able to detect plaques in the brainstem, cerebellum and within the cervical spinal cord. MR appears to be an important, non-invasive method for the diagnosis of Multiple Sclerosis and has proven to be diagnostically superior to CT, evoked potentials (EP) and CSF examination. In a selected group of 30 patients, with the whole battery of the relevant MS studies, MR was positive in 100%, CT in 33,3%, EP in 56% and CSF examination in 60%. In patients clinically presenting only with signs of spinal cord involvement or optic neuritis or when the clinical presentation is uncertain MR has proven to be a very useful diagnostic tool for diagnosis of MS by demonstrating unsuspected lesions in the cerebral hemispheres. (orig.)

  19. Study of detection probability from lesion by scintiscanning

    International Nuclear Information System (INIS)

    Silva, D.C. da; Dias-Neto, A.L.

    1992-01-01

    The importance of work with the information density parameter in scintiscanning is described, fixing the minimum values of information density, above of which the existent injuries are not detected, allowing also the reproducibility of the examination. (C.G.C.)

  20. Automated lesion detection on MRI scans using combined unsupervised and supervised methods

    International Nuclear Information System (INIS)

    Guo, Dazhou; Fridriksson, Julius; Fillmore, Paul; Rorden, Christopher; Yu, Hongkai; Zheng, Kang; Wang, Song

    2015-01-01

    Accurate and precise detection of brain lesions on MR images (MRI) is paramount for accurately relating lesion location to impaired behavior. In this paper, we present a novel method to automatically detect brain lesions from a T1-weighted 3D MRI. The proposed method combines the advantages of both unsupervised and supervised methods. First, unsupervised methods perform a unified segmentation normalization to warp images from the native space into a standard space and to generate probability maps for different tissue types, e.g., gray matter, white matter and fluid. This allows us to construct an initial lesion probability map by comparing the normalized MRI to healthy control subjects. Then, we perform non-rigid and reversible atlas-based registration to refine the probability maps of gray matter, white matter, external CSF, ventricle, and lesions. These probability maps are combined with the normalized MRI to construct three types of features, with which we use supervised methods to train three support vector machine (SVM) classifiers for a combined classifier. Finally, the combined classifier is used to accomplish lesion detection. We tested this method using T1-weighted MRIs from 60 in-house stroke patients. Using leave-one-out cross validation, the proposed method can achieve an average Dice coefficient of 73.1 % when compared to lesion maps hand-delineated by trained neurologists. Furthermore, we tested the proposed method on the T1-weighted MRIs in the MICCAI BRATS 2012 dataset. The proposed method can achieve an average Dice coefficient of 66.5 % in comparison to the expert annotated tumor maps provided in MICCAI BRATS 2012 dataset. In addition, on these two test datasets, the proposed method shows competitive performance to three state-of-the-art methods, including Stamatakis et al., Seghier et al., and Sanjuan et al. In this paper, we introduced a novel automated procedure for lesion detection from T1-weighted MRIs by combining both an unsupervised and a

  1. Cylindrical SUV distribution model for detecting skin lesions in body trunk FDG-PET/CT images

    International Nuclear Information System (INIS)

    Nemoto, Mitsutaka; Nomura, Yukihiro; Masutani, Yoshitaka; Yoshikawa, Takeharu; Hayashi, Naoto; Yoshioka, Naoki; Ohtomo, Kuni; Hanaoka, Shouhei

    2010-01-01

    We have been developing a computerized detection method for skin lesions in body trunk fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT images. Spots on the skin with a high standard uptake value (SUV) are due not only to glucose metabolism in skin lesions but also to the physiological metabolism of organs near the skin. The distribution pattern of regional SUV on the skin is important information for the differential diagnosis of such high-SUV spots. In this study, we have developed a new skin lesion detection method based on a cylindrical SUV distribution model of the skin. The shape of the SUV distribution model is an approximation of the body trunk, and the SUV distribution model includes standard values for regional skin SUV. Classifier ensembles based on CT image features, SUV features, and subtraction features between the SUVs in FDG-PET images and the values in the SUV distribution model are used to extract and classify candidate regions for skin lesions. In a study of skin lesion detection using FDG-PET/CT images in 36 clinical cases, the true-positive rate was 61.7%, with 11.7 false-positive regions per case. The training results of the classifier ensemble for extracting and classifying candidate regions showed the effective features for detecting skin lesions in the study. (author)

  2. A comparative study of the detectability of TMJ radiographic techniques for artificial mandibular condylar lesions

    International Nuclear Information System (INIS)

    Jeong, Hee Jeong; Jung, Yeon Hwa; Cho, Bong Hae

    1997-01-01

    The purpose of this study was to evaluate the detectability of various radiographic techniques for mandibular condylar lesions. Erosive lesion, osteophyte and flattening were formed on the artificial mandibular condyle, and panoramic, transcranial, transorbital radiography, lateral and frontal tomography were taken. The results were as follows; 1. The detectability for erosive lesions was superior in the order of frontal tomography (96%), lateral tomography (78%), transorbital (59%), transcranial (56%) and panoramic (48%) radiography. 2. The location of erosive lesion that showed the highest detectability was the medial third in panoramic, the lateral third in transcranial, the central portion of anteroposterior direction in transorbital, the central portion of mediolateral direction and the posterior third in lateral tomography. Frontal tomography disclosed all erosive lesions except one anterolateral lesion. 3. The detectability of osteophyte was 100% in lateral tomography, 78% in transcranial and 56% in panoramic radiography. 4. For flattening, lateral tomography showed the flattened condyle, but both panoramic and transcranial views showed only decreased bone density without the change of condylar shape.

  3. Ultrasound-guided wire localization of lesions detected on ...

    African Journals Online (AJOL)

    Background: Wire localization for planned surgical treatment in the management of breast cancer is underutilized in our environment. The objective of this study is to assess the role of ultrasound-guided wire localization of breast masses detected on screening mammography and its impact on biopsy and breast ...

  4. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    International Nuclear Information System (INIS)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub; You, Joshua H.; Lee, Ji Yong; Whang, Kum

    2010-01-01

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  5. Detection of atherosclerotic lesions and intimal macrophages using CD36-targeted nanovesicles.

    Science.gov (United States)

    Nie, Shufang; Zhang, Jia; Martinez-Zaguilan, Raul; Sennoune, Souad; Hossen, Md Nazir; Lichtenstein, Alice H; Cao, Jun; Meyerrose, Gary E; Paone, Ralph; Soontrapa, Suthipong; Fan, Zhaoyang; Wang, Shu

    2015-12-28

    Current approaches to the diagnosis and therapy of atherosclerosis cannot target lesion-determinant cells in the artery wall. Intimal macrophage infiltration promotes atherosclerotic lesion development by facilitating the accumulation of oxidized low-density lipoproteins (oxLDL) and increasing inflammatory responses. The presence of these cells is positively associated with lesion progression, severity and destabilization. Hence, they are an important diagnostic and therapeutic target. The objective of this study was to noninvasively assess the distribution and accumulation of intimal macrophages using CD36-targeted nanovesicles. Soy phosphatidylcholine was used to synthesize liposome-like nanovesicles. 1-(Palmitoyl)-2-(5-keto-6-octene-dioyl) phosphatidylcholine was incorporated on their surface to target the CD36 receptor. All in vitro data demonstrate that these targeted nanovesicles had a high binding affinity for the oxLDL binding site of the CD36 receptor and participated in CD36-mediated recognition and uptake of nanovesicles by macrophages. Intravenous administration into LDL receptor null mice of targeted compared to non-targeted nanovesicles resulted in higher uptake in aortic lesions. The nanovesicles co-localized with macrophages and their CD36 receptors in aortic lesions. This molecular target approach may facilitate the in vivo noninvasive imaging of atherosclerotic lesions in terms of intimal macrophage accumulation and distribution and disclose lesion features related to inflammation and possibly vulnerability thereby facilitate early lesion detection and targeted delivery of therapeutic compounds to intimal macrophages. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Detection of white matter lesion regions in MRI using SLIC0 and convolutional neural network.

    Science.gov (United States)

    Diniz, Pedro Henrique Bandeira; Valente, Thales Levi Azevedo; Diniz, João Otávio Bandeira; Silva, Aristófanes Corrêa; Gattass, Marcelo; Ventura, Nina; Muniz, Bernardo Carvalho; Gasparetto, Emerson Leandro

    2018-04-19

    White matter lesions are non-static brain lesions that have a prevalence rate up to 98% in the elderly population. Because they may be associated with several brain diseases, it is important that they are detected as soon as possible. Magnetic Resonance Imaging (MRI) provides three-dimensional data with the possibility to detect and emphasize contrast differences in soft tissues, providing rich information about the human soft tissue anatomy. However, the amount of data provided for these images is far too much for manual analysis/interpretation, representing a difficult and time-consuming task for specialists. This work presents a computational methodology capable of detecting regions of white matter lesions of the brain in MRI of FLAIR modality. The techniques highlighted in this methodology are SLIC0 clustering for candidate segmentation and convolutional neural networks for candidate classification. The methodology proposed here consists of four steps: (1) images acquisition, (2) images preprocessing, (3) candidates segmentation and (4) candidates classification. The methodology was applied on 91 magnetic resonance images provided by DASA, and achieved an accuracy of 98.73%, specificity of 98.77% and sensitivity of 78.79% with 0.005 of false positives, without any false positives reduction technique, in detection of white matter lesion regions. It is demonstrated the feasibility of the analysis of brain MRI using SLIC0 and convolutional neural network techniques to achieve success in detection of white matter lesions regions. Copyright © 2018. Published by Elsevier B.V.

  7. Bright Retinal Lesions Detection using Colour Fundus Images Containing Reflective Features

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Karnowski, Thomas Paul [ORNL; Chaum, Edward [ORNL; Meriaudeau, Fabrice [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK)

    2009-01-01

    In the last years the research community has developed many techniques to detect and diagnose diabetic retinopathy with retinal fundus images. This is a necessary step for the implementation of a large scale screening effort in rural areas where ophthalmologists are not available. In the United States of America, the incidence of diabetes is worryingly increasing among the young population. Retina fundus images of patients younger than 20 years old present a high amount of reflection due to the Nerve Fibre Layer (NFL), the younger the patient the more these reflections are visible. To our knowledge we are not aware of algorithms able to explicitly deal with this type of reflection artefact. This paper presents a technique to detect bright lesions also in patients with a high degree of reflective NFL. First, the candidate bright lesions are detected using image equalization and relatively simple histogram analysis. Then, a classifier is trained using texture descriptor (Multi-scale Local Binary Patterns) and other features in order to remove the false positives in the lesion detection. Finally, the area of the lesions is used to diagnose diabetic retinopathy. Our database consists of 33 images from a telemedicine network currently developed. When determining moderate to high diabetic retinopathy using the bright lesions detected the algorithm achieves a sensitivity of 100% at a specificity of 100% using hold-one-out testing.

  8. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    International Nuclear Information System (INIS)

    Gehl, H.B.; Bourne, M.; Grazioli, L.; Moeller, A.; Lodemann, K.P.

    2001-01-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  9. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gehl, H.B. [Inst. of Diagnostic Radiology, Medical Univ. of Luebeck (Germany); Bourne, M. [Dept. of Radiology, Univ. Hospital of Wales, Cardiff (United Kingdom); Grazioli, L. [Dept. of Radiology, Univ. of Brescia (Italy); Moeller, A. [MEDIDATA GmbH, Konstanz (Germany); Lodemann, K.P. [BRACCO-BYK GULDEN GmbH, Konstanz (Germany)

    2001-02-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  10. Temporal characteristics of radiologists’ and novices’ lesion detection in viewing medical images presented rapidly and sequentially

    Directory of Open Access Journals (Sweden)

    Ryoichi Nakashima

    2016-10-01

    Full Text Available Although viewing multiple stacks of medical images presented on a display is a relatively new but useful medical task, little is known about this task. Particularly, it is unclear how radiologists search for lesions in this type of image reading. When viewing cluttered and dynamic displays, continuous motion itself does not capture attention. Thus, it is effective for the target detection that observers’ attention is captured by the onset signal of a suddenly appearing target among the continuously moving distractors (i.e., a passive viewing strategy. This can be applied to stack viewing tasks, because lesions often show up as transient signals in medical images which are sequentially presented simulating a dynamic and smoothly transforming image progression of organs. However, it is unclear whether observers can detect a target when the target appears at the beginning of a sequential presentation where the global apparent motion onset signal (i.e., signal of the initiation of the apparent motion by sequential presentation occurs. We investigated the ability of radiologists to detect lesions during such tasks by comparing the performances of radiologists and novices. Results show that overall performance of radiologists is better than novices. Furthermore, the temporal locations of lesions in CT image sequences, i.e., when a lesion appears in an image sequence, does not affect the performance of radiologists, whereas it does affect the performance of novices. Results indicate that novices have greater difficulty in detecting a lesion appearing early than late in the image sequence. We suggest that radiologists have other mechanisms to detect lesions in medical images with little attention which novices do not have. This ability is critically important when viewing rapid sequential presentations of multiple CT images, such as stack viewing tasks.

  11. Oligodendrogenesis and neurogenesis in remyelination in the cuprizone model of multiple sclerosis: correlation with the degree of lesion

    Science.gov (United States)

    Pishchelko, A.; Khodanovich, M.; Pan, E.; Glazacheva, V.; Akulov, A.; Yarnykh, V.

    2017-08-01

    In this research, a cuprizone model of multiple sclerosis (MS) was used to study oligodendrogenesis and neurogenesis in remyelination. It has been shown that, with the administration of cuprizone, the amount of myelin in a number of structures of white and gray matter and the level of neurogenesis decrease, while the level of oligodendrogenesis increases. The withdrawal of cuprizone leads to the restoration of myelin content, the reduction of the excessive production of oligodendrocytes and to the restoration of the number of neurons to control values. The negative correlation between the number of oligodendrocyte precursors (OPCs) and the degree of demyelination of the corpus callosum indicates migration of OLG precursors from the subventricular zone (SVZ) to the structure during demyelination.

  12. Comparison of Digital Tomosynthesis and Chest Radiography for the Detection of Noncalcified Pulmonary and Hilar Lesions.

    Science.gov (United States)

    Galea, Angela; Adlan, Tarig; Gay, David; Roobottom, Carl; Dubbins, Paul; Riordan, Richard

    2015-09-01

    The aim of this study was to compare the sensitivity and specificity of chest digital tomosynthesis (DTS) with chest radiography (CXR) for the detection of noncalcified pulmonary nodules and hilar lesions using computed tomography (CT) as the reference standard. A total of 78 patients with suspected noncalcified pulmonary lesions on CXR were included in the study. Two radiologists, blinded to the history and CT, analyzed the CXR and the DTS images (separately), whereas a third radiologist analyzed the CXR and DTS images together. Noncalcified intrapulmonary nodules and hilar lesions were recorded for analysis. The interobserver agreement for CXR and DTS was assessed, and the time taken to report the images was recorded. A total of 202 lesions were recorded in 78 patients. There were 111 true lesions confirmed on CT in 53 patients; in 25 patients subsequent CT excluded a lesion. The overall sensitivity was 32% for CXR and 49% for DTS. This improved to 54% when the posteroanterior CXR and DTS were reviewed together (CXR-DTS). The overall specificities for CXR, DTS, and CXR-DTS were 49%, 96%, and 98%, respectively. There were 56 suspected hilar lesions with subgroup sensitivities of 76% for CXR, 65% for DTS, and 76% for CXR-DTS. The specificity for hilar lesions was 59%, 92%, and 97% for CXR, DTS, and CXR-DTS, respectively. DTS significantly improves the detectability of noncalcified nodules when compared with and when used in combination with CXR. The specificity and interobserver agreement of DTS in the diagnosis of suspected noncalcified pulmonary nodules and hilar lesions are significantly better than those of CXR and approaches those of CT.

  13. Automatic segmentation of lesions for the computer-assisted detection in fluorescence urology

    Science.gov (United States)

    Kage, Andreas; Legal, Wolfgang; Kelm, Peter; Simon, Jörg; Bergen, Tobias; Münzenmayer, Christian; Benz, Michaela

    2012-03-01

    Bladder cancer is one of the most common cancers in the western world. The diagnosis in Germany is based on the visual inspection of the bladder. This inspection performed with a cystoscope is a challenging task as some kinds of abnormal tissues do not differ much in their appearance from their surrounding healthy tissue. Fluorescence Cystoscopy has the potential to increase the detection rate. A liquid marker introduced into the bladder in advance of the inspection is concentrated in areas with high metabolism. Thus these areas appear as bright "glowing". Unfortunately, the fluorescence image contains besides the glowing of the suspicious lesions no more further visual information like for example the appearance of the blood vessels. A visual judgment of the lesion as well as a precise treatment has to be done using white light illumination. Thereby, the spatial information of the lesion provided by the fluorescence image has to be guessed by the clinical expert. This leads to a time consuming procedure due to many switches between the modalities and increases the risk of mistreatment. We introduce an automatic approach, which detects and segments any suspicious lesion in the fluorescence image automatically once the image was classified as a fluorescence image. The area of the contour of the detected lesion is transferred to the corresponding white light image and provide the clinical expert the spatial information of the lesion. The advantage of this approach is, that the clinical expert gets the spatial and the visual information of the lesion together in one image. This can save time and decrease the risk of an incomplete removal of a malign lesion.

  14. Hierarchical detection of red lesions in retinal images by multiscale correlation filtering

    Science.gov (United States)

    Zhang, Bob; Wu, Xiangqian; You, Jane; Li, Qin; Karray, Fakhri

    2009-02-01

    This paper presents an approach to the computer aided diagnosis (CAD) of diabetic retinopathy (DR) -- a common and severe complication of long-term diabetes which damages the retina and cause blindness. Since red lesions are regarded as the first signs of DR, there has been extensive research on effective detection and localization of these abnormalities in retinal images. In contrast to existing algorithms, a new approach based on Multiscale Correlation Filtering (MSCF) and dynamic thresholding is developed. This consists of two levels, Red Lesion Candidate Detection (coarse level) and True Red Lesion Detection (fine level). The approach was evaluated using data from Retinopathy On-line Challenge (ROC) competition website and we conclude our method to be effective and efficient.

  15. Theoretical evaluation of the detectability of random lesions in bayesian emission reconstruction

    International Nuclear Information System (INIS)

    Qi, Jinyi

    2003-01-01

    Detecting cancerous lesion is an important task in positron emission tomography (PET). Bayesian methods based on the maximum a posteriori principle (also called penalized maximum likelihood methods) have been developed to deal with the low signal to noise ratio in the emission data. Similar to the filter cut-off frequency in the filtered backprojection method, the prior parameters in Bayesian reconstruction control the resolution and noise trade-off and hence affect detectability of lesions in reconstructed images. Bayesian reconstructions are difficult to analyze because the resolution and noise properties are nonlinear and object-dependent. Most research has been based on Monte Carlo simulations, which are very time consuming. Building on the recent progress on the theoretical analysis of image properties of statistical reconstructions and the development of numerical observers, here we develop a theoretical approach for fast computation of lesion detectability in Bayesian reconstruction. The results can be used to choose the optimum hyperparameter for the maximum lesion detectability. New in this work is the use of theoretical expressions that explicitly model the statistical variation of the lesion and background without assuming that the object variation is (locally) stationary. The theoretical results are validated using Monte Carlo simulations. The comparisons show good agreement between the theoretical predications and the Monte Carlo results

  16. Automated volumetry for unilateral hippocampal sclerosis detection in patients with temporal lobe epilepsy.

    Science.gov (United States)

    Martins, Cristina; Moreira da Silva, Nadia; Silva, Guilherme; Rozanski, Verena E; Silva Cunha, Joao Paulo

    2016-08-01

    Hippocampal sclerosis (HS) is the most common cause of temporal lobe epilepsy (TLE) and can be identified in magnetic resonance imaging as hippocampal atrophy and subsequent volume loss. Detecting this kind of abnormalities through simple radiological assessment could be difficult, even for experienced radiologists. For that reason, hippocampal volumetry is generally used to support this kind of diagnosis. Manual volumetry is the traditional approach but it is time consuming and requires the physician to be familiar with neuroimaging software tools. In this paper, we propose an automated method, written as a script that uses FSL-FIRST, to perform hippocampal segmentation and compute an index to quantify hippocampi asymmetry (HAI). We compared the automated detection of HS (left or right) based on the HAI with the agreement of two experts in a group of 19 patients and 15 controls, achieving 84.2% sensitivity, 86.7% specificity and a Cohen's kappa coefficient of 0.704. The proposed method is integrated in the "Advanced Brain Imaging Lab" (ABrIL) cloud neurocomputing platform. The automated procedure is 77% (on average) faster to compute vs. the manual volumetry segmentation performed by an experienced physician.

  17. Using Eulerian video magnification to enhance detection of fasciculations in people with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Van Hillegondsberg, Ludo; Carr, Jonathan; Brey, Naeem; Henning, Franclo

    2017-12-01

    This study seeks to determine whether the use of Eulerian video magnification (EVM) increases the detection of muscle fasciculations in people with amyotrophic lateral sclerosis (PALS) compared with direct clinical observation (DCO). Thirty-second-long video recordings were taken of 9 body regions of 7 PALS and 7 controls, and fasciculations were counted by DCO during the same 30-s period. The video recordings were then motion magnified and reviewed by 2 independent assessors. In PALS, median fasciculation count per body region was 1 by DCO (range 0-10) and 3 in the EVM recordings (range 0-15; P < 0.0001). EVM revealed more fasciculations than DCO in 61% of recordings. In controls, median fasciculation count was 0 for both DCO and EVM. Compared with DCO, EVM significantly increased the detection of fasciculations in body regions of PALS. When it is used to supplement clinical examination, EVM has the potential to facilitate the diagnosis of ALS. Muscle Nerve 56: 1063-1067, 2017. © 2017 Wiley Periodicals, Inc.

  18. Low tube voltage CT for improved detection of pancreatic cancer: detection threshold for small, simulated lesions

    International Nuclear Information System (INIS)

    Holm, Jon; Loizou, Louiza; Albiin, Nils; Kartalis, Nikolaos; Leidner, Bertil; Sundin, Anders

    2012-01-01

    Pancreatic ductal adenocarcinoma is associated with dismal prognosis. The detection of small pancreatic tumors which are still resectable is still a challenging problem. The aim of this study was to investigate the effect of decreasing the tube voltage from 120 to 80 kV on the detection of pancreatic tumors. Three scanning protocols was used; one using the standard tube voltage (120 kV) and current (160 mA) and two using 80 kV but with different tube currents (500 and 675 mA) to achieve equivalent dose (15 mGy) and noise (15 HU) as that of the standard protocol. Tumors were simulated into collected CT phantom images. The attenuation in normal parenchyma at 120 kV was set at 130 HU, as measured previously in clinical examinations, and the tumor attenuation was assumed to differ 20 HU and was set at 110HU. By scanning and measuring of iodine solution with different concentrations the corresponding tumor and parenchyma attenuation at 80 kV was found to be 185 and 219 HU, respectively. To objectively evaluate the differences between the three protocols, a multi-reader multi-case receiver operating characteristic study was conducted, using three readers and 100 cases, each containing 0–3 lesions. The highest reader averaged figure-of-merit (FOM) was achieved for 80 kV and 675 mA (FOM = 0,850), and the lowest for 120 kV (FOM = 0,709). There was a significant difference between the three protocols (p < 0,0001), when making an analysis of variance (ANOVA). Post-hoc analysis (students t-test) shows that there was a significant difference between 120 and 80 kV, but not between the two levels of tube currents at 80 kV. We conclude that when decreasing the tube voltage there is a significant improvement in tumor conspicuity

  19. Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

    Science.gov (United States)

    Wunderlich, Adam; Noo, Frédéric

    2008-05-21

    We consider noise in computed tomography images that are reconstructed using the classical direct fan-beam filtered backprojection algorithm, from both full- and short-scan data. A new, accurate method for computing image covariance is presented. The utility of the new covariance method is demonstrated by its application to the implementation of a channelized Hotelling observer for a lesion detection task. Results from the new covariance method and its application to the channelized Hotelling observer are compared with results from Monte Carlo simulations. In addition, the impact of a bowtie filter and x-ray tube current modulation on reconstruction noise and lesion detectability are explored for full-scan reconstruction.

  20. Image covariance and lesion detectability in direct fan-beam x-ray computed tomography

    International Nuclear Information System (INIS)

    Wunderlich, Adam; Noo, Frederic

    2008-01-01

    We consider noise in computed tomography images that are reconstructed using the classical direct fan-beam filtered backprojection algorithm, from both full- and short-scan data. A new, accurate method for computing image covariance is presented. The utility of the new covariance method is demonstrated by its application to the implementation of a channelized Hotelling observer for a lesion detection task. Results from the new covariance method and its application to the channelized Hotelling observer are compared with results from Monte Carlo simulations. In addition, the impact of a bowtie filter and x-ray tube current modulation on reconstruction noise and lesion detectability are explored for full-scan reconstruction

  1. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  2. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    International Nuclear Information System (INIS)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye; Song, Byung Joo; Choe, Byung Joo; Park, Sarah; Kim, Hyunbin

    2013-01-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement

  3. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Song, Byung Joo; Choe, Byung Joo [Department of General Surgery, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Park, Sarah [Department of Internal Medicine, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Kim, Hyunbin [CMC Clinical Research Coordinating Center, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of)

    2013-07-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement.

  4. Molecular detection of Leptospira spp. from canine kidney tissues and its association with renal lesions

    Directory of Open Access Journals (Sweden)

    Biswajit R. Dash

    2018-04-01

    Full Text Available Aim: The study aimed to detect the prevalence of Leptospira spp. in kidney tissues collected during necropsy and to establish its association with renal lesions in dogs of Mumbai region. Materials and Methods: Kidney tissues from 40 dogs were collected during necropsy after gross examination and then fixed in neutral buffered formalin and Bouin's fluid for histopathology and histochemistry, respectively. Kidney tissues were also collected for the detection of Leptospira spp. by polymerase chain reaction (PCR in a sterile container and stored at -80°C until further processing. Results: Of 40 cases studied, 13 (32.5% cases showed lesions of nephritis of varying histotype and severity. Glomerulonephritis was reported as the most common type of nephritis in 9 (69.23% cases, and interstitial nephritis was recorded in 4 (30.76% cases. Chronic and acute interstitial nephritis was observed in two cases each. Renal failure as a cause of death was found in 7 (17.5% dogs. Of a total of 40 cases, 9 were found positive for pathogenic Leptospira spp. genome by PCR. However, of nine PCR-positive cases, only four cases showed lesions in kidneys as glomerulonephritis and interstitial nephritis in two cases each. The rest five cases positive for Leptospira spp. by PCR did not show any appreciable lesions in the kidneys. Conclusion: Leptospiral DNA was detected in 9 (22.5% cases by PCR. Of these nine cases, only four cases showed renal lesions. Other five cases which were positive for Leptospira spp. by PCR did not show any appreciable gross and microscopic lesions in the kidneys which might be carriers for Leptospira spp. Considering variable reports on types of nephritis in Leptospira spp. infection and also the prevalence of non-pathogenic Leptospira spp., it is important to conduct an extensive study on the prevalence of Leptospira spp. and its association with renal lesions involving batteries of tests.

  5. Detection of early carious lesions using contrast enhancement with coherent light scattering (speckle imaging)

    International Nuclear Information System (INIS)

    Deana, A M; Jesus, S H C; Koshoji, N H; Bussadori, S K; Oliveira, M T

    2013-01-01

    Currently, dental caries still represent one of the chronic diseases with the highest prevalence and present in most countries. The interaction between light and teeth (absorption, scattering and fluorescence) is intrinsically connected to the constitution of the dental tissue. Decay induced mineral loss introduces a shift in the optical properties of the affected tissue; therefore, study of these properties may produce novel techniques aimed at the early diagnosis of carious lesions. Based on the optical properties of the enamel, we demonstrate the application of first-order spatial statistics in laser speckle imaging, allowing the detection of carious lesions in their early stages. A highlight of this noninvasive, non-destructive, real time and cost effective approach is that it allows a dentist to detect a lesion even in the absence of biofilm or moisture. (paper)

  6. Brain magnetic resonance imaging findings in patients with systemic sclerosis.

    Science.gov (United States)

    Mohamed, Reem H A; Nassef, Amr A

    2010-02-01

    Systemic sclerosis is a multisystem disease where functional and structural abnormalities of small blood vessels prevail. Recently, transient ischemic attacks, ischemic stroke, and hemorrhages have been reported as primary consequence of vascular central nervous system affection in systemic sclerosis. Magnetic resonance imaging (MRI) is considered to be the most sensitive diagnostic technique for detecting symptomatic and asymptomatic lesions in the brain in cases of multifocal diseases. Evaluate brain changes in patients with systemic sclerosis using MRI. Thirty female patients with systemic sclerosis aged 27-61 years, with disease duration of 1-9 years and with no history of other systemic disease or cerebrovascular accidents, were enrolled. An age-matched female control group of 30 clinically normal subjects, underwent brain MR examination. Central nervous system involvement in the form of white matter hyperintense foci of variable sizes were found in significantly abundant forms in systemic sclerosis patients on MR evaluation than in the age-related control group, signifying a form of central nervous system vasculopathy. Such foci showed no definite correlation with disease duration, yet they showed significant correlation to severity of peripheral vascular disease, headaches, fainting attacks and depression in the group under study. Asymptomatic as well as symptomatic central nervous system ischemic vasculopathy is not uncommon in systemic sclerosis patients and MRI is considered a sensitive noninvasive screening tool for early detection of CNS involvement in patients with systemic sclerosis.

  7. Evaluation of the application of chemical shift for the detection of lipid in brain lesion

    Energy Technology Data Exchange (ETDEWEB)

    Lim, C.J. [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya Medical Centre, Kuala Lumpur (Malaysia); Ng, K.H., E-mail: ngkh@um.edu.m [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya Medical Centre, Kuala Lumpur (Malaysia); Ramli, N.; Azman, R.R. [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya Medical Centre, Kuala Lumpur (Malaysia)

    2011-02-15

    Non-invasive detection of the presence of lipids is particularly important in staging of intracranial tumours. Presence of lipid peak in aggressive intracranial tumours has been reported widely using MR spectroscopy. However this method has limitation due to long imaging time and artefacts formed by adjacent bones. Chemical shift MR imaging (with has shorter imaging time) is an alternative method that had been used to detect presence of lipid in vivo by means of signal intensity loss. The purpose of this study was to evaluate gradient echo in- and opposed-phase chemical shift pulse sequences for detection of lipid elements in brain lesion. Ten cylindered phantoms measuring 3 x 3 cm were filled with various mixtures of lipid and water: 0-90% lipid, in 10% step by weight. The gradient echo in- and opposed-phase chemical shift sequences were performed using a 1.5 T MRI (Magnetom Vision, Siemens) with a head coil. In addition, we performed MRI and chemical shift studies on 32 patients with brain lesion. We then analysed the association between out of phase intensity value and classification of the lesions. For phantom containing 50% lipid, maximum signal loss on opposed-phase images was observed. There were significant differences between in- and opposed-phase lipid-water phantom images (P = 0.0054). Most of the benign lesions fall into the positive out of phase intensity value, and malignant lesions fall into negative out of phase intensity value. We conclude that chemical shift artefact can be applied in detecting and characterising lipid elements in brain lesion.

  8. Detection of oral early cancerous lesion by using polarization-sensitive optical coherence tomography: mice model

    Science.gov (United States)

    Lee, Hong-Yi; Chen, Ping-Hsien; Lee, Tzu-Han; Chang, Kuo-Wei; Kuo, Wen-Chuan

    2018-02-01

    Oral cancer is the 11th most common cancer worldwide, especially in a male adult. The median age of death in oral cancer was 55 years, 10-20 years earlier than other cancers. Presently, oral cancer is often found in late stage, because the lesion is often flat in early stage and is difficult to diagnose under traditional white light imaging. The only definitive method for determining cancer is an invasive biopsy and then using histology examination. How to detect precancerous lesions or early malignant lesions is an important issue for improving prognosis of oral cancer. Optical coherence tomography (OCT) is a new optical tool for diagnosing early malignant lesions in the skin or gastrointestinal tract recently. Here we report a new method for detecting precancerous or early malignant oral lesions by using swept source polarization-sensitive optical coherence tomography (PS-OCT) with center-wavelength 1310 nm, bandwidth 110 nm and 100 kHz swept rate. We used all single-mode fiber design to detect the change of birefringence information in the epithelium structure. This system has an advantage that enables measurement of backscattered intensity and birefringence simultaneously with only one A-scan per transverse location. In preliminary result, we computed the slope of the every A-scan signal in tissue part using a linear-curve fitting in backscattered intensity and birefringence on the enface. In this research, we used an oral cancer mice model for observing the change of structure and birefringence properties in different stages of oral cancer mice. We presented the parametric enface imaging that can detect the early oral malignant lesions.

  9. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents

    International Nuclear Information System (INIS)

    Hohmann, J.; Albrecht, T.; Hoffmann, C.W.; Wolf, K.-J.

    2003-01-01

    Ultrasonography (US) is the first choice for screening patients with suspected liver lesions. However, due to a lack of contrast agents, US used to be less sensitive and specific compared with computed tomography (CT) and magnet resonance imaging (MRI). The advent of microbubble contrast agents increased both sensitivity and specificity dramatically. Rapid developments of the contrast agents as well as of special imaging techniques were made in recent years. Today numerous different US imaging methods exist which based either on Doppler or on harmonic imaging. They are using the particular behaviour of microbubbles in a sound field which varies depending on the energy of insonation (low/high mechanical index, MI) as well as on the properties of the agent themselves. Apart from just blood pool enhancement some agents have a hepatosplenic specific late phase. US imaging during this late phase using relatively high MI in phase inversion mode (harmonic imaging) or stimulated acoustic emission (SAE; Doppler method) markedly improves the detection of focal liver lesions and is also very helpful for lesion characterisation. With regards to detection, contrast enhanced US performs similarly to CT as shown by recent studies. Early results of studies using low MI imaging and the newer perfluor agents are also showing promising results for lesion detection. Low MI imaging with these agents has the advantage of real time imaging and is particularly helpful for characterisation of focal lesions based on their dynamic contrast behaviour. Apart from the techniques which based on the morphology of liver lesions there were some attempts for the detection of occult metastases or micrometastases by means of liver blood flow changes. Also in this field the use of US contrast agents appears to have advantages over formerly used non contrast-enhanced methods although no conclusive results are available yet

  10. Evaluation of the application of chemical shift for the detection of lipid in brain lesion

    International Nuclear Information System (INIS)

    Lim, C.J.; Ng, K.H.; Ramli, N.; Azman, R.R.

    2011-01-01

    Non-invasive detection of the presence of lipids is particularly important in staging of intracranial tumours. Presence of lipid peak in aggressive intracranial tumours has been reported widely using MR spectroscopy. However this method has limitation due to long imaging time and artefacts formed by adjacent bones. Chemical shift MR imaging (with has shorter imaging time) is an alternative method that had been used to detect presence of lipid in vivo by means of signal intensity loss. The purpose of this study was to evaluate gradient echo in- and opposed-phase chemical shift pulse sequences for detection of lipid elements in brain lesion. Ten cylindered phantoms measuring 3 x 3 cm were filled with various mixtures of lipid and water: 0-90% lipid, in 10% step by weight. The gradient echo in- and opposed-phase chemical shift sequences were performed using a 1.5 T MRI (Magnetom Vision, Siemens) with a head coil. In addition, we performed MRI and chemical shift studies on 32 patients with brain lesion. We then analysed the association between out of phase intensity value and classification of the lesions. For phantom containing 50% lipid, maximum signal loss on opposed-phase images was observed. There were significant differences between in- and opposed-phase lipid-water phantom images (P = 0.0054). Most of the benign lesions fall into the positive out of phase intensity value, and malignant lesions fall into negative out of phase intensity value. We conclude that chemical shift artefact can be applied in detecting and characterising lipid elements in brain lesion.

  11. Memory and learning disturbances in multiple sclerosis

    International Nuclear Information System (INIS)

    Izquierdo, Guillermo; Mir, Jordi; Gonzalez, Manuel; Martinez-Parra, Carlos; Campoy, Francisco Jr

    1991-01-01

    Thirty-five patients with definite multiple sclerosis (MS) were studied. They underwent neuropsychological testing and magnetic resonance imaging (MRI). The MRI findings at different brain areas levels were compared with the neuropsychological findings. A quantitative system was used to measure MRI-MS lesions. In this series, a positive correlation was established between memory and learning disturbances measured by Battery 144, and the lesions measured by MRI (total, hemispheric and , particularly, periventricular lesions). MRI can detect MS lesions, and this study shows that a correlation between MRI and neuropsychological findings is possible if quantitative methods are used to distinguish different MS involvement areas in relation to neuropsychological tasks. These findings suggest that hemispheric lesions in MS produce cognitive disturbances and MRI could be a useful tool in predicting memory and learning impairment. (author). 20 refs.; 1 fig.; 2 tabs

  12. Importance of Defect Detectability in Positron Emission Tomography Imaging of Abdominal Lesions

    International Nuclear Information System (INIS)

    Yamashita, Shozo; Yokoyama, Kunihiko; Onoguchi, Masahisa; Yamamoto, Haruki; Nakaichi, Tetsu; Tsuji, Shiro; Nakajima, Kenichi

    2015-01-01

    This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 min, were reconstructed using VUE point HD and a 4.7 mm full-width at half-maximum (FWHM) Gaussian filter. Iteration-subset combinations of 2-16 and 2-32 were used. Visual and physical analyses were performed using the acquired images. To sequentially evaluate defect detectability in clinical settings, we examined two middle-aged male subjects. One had a liver cyst (approximately 10 mm in diameter) and the other suffered from pancreatic cancer with an inner defect region (approximately 9 mm in diameter). In the phantom study, at least 6 and 3 min acquisition durations were required to visualize 10 and 13 mm defect spheres, respectively. On the other hand, spheres with diameters ≥17 mm could be detected even if the acquisition duration was only 1 min. The visual scores were significantly correlated with background (BG) variability. In clinical settings, the liver cyst could be slightly visualized with an acquisition duration of 6 min, although image quality was suboptimal. For pancreatic cancer, the acquisition duration of 3 min was insufficient to clearly describe the defect region. The improvement of BG variability is the most important factor for enhancing lesion detection. Our clinical scan duration (3 min/bed) may not be suitable for the detection of small lesions or accurate tumor delineation since an acquisition duration of at least 6 min is required to visualize 10 mm lesions, regardless of reconstruction parameters. Improvements in defect detectability are important for radiation treatment planning and accurate PET-based diagnosis

  13. Exploring sarcasm detection in Amyotrophic Lateral Sclerosis using ecologically valid measures

    Directory of Open Access Journals (Sweden)

    Mathew eStaios

    2013-05-01

    Full Text Available Amyotrophic lateral sclerosis is a rapidly progressive condition involving degeneration of both upper and lower motor neurons. Recent research suggests that a proportion of persons with ALS show a profile similar to that of FTD, with this group of ALS patients exhibiting social cognitive deficits. Although social cognitive deficits have been partially explored in ALS, research has yet to investigate such changes using ecologically valid measures. Therefore, this study aimed to further characterise the scope of social cognitive and emotion recognition deficits in non-demented ALS patients using an ecologically valid measure of social cognition. A sample of 35 ALS patients and 30 age-and-education matched controls were assessed using the Addenbrooke’s Cognitive Examination, the Brixton Spatial Anticipation Test, and The Awareness of Social Inference Test, where participants were required to discriminate between various emotions and decipher socially challenging scenarios enacted in video vignettes. Participants with ALS showed significant difficulties in recognising both sarcastic and paradoxical sarcastic statements, but not sincere statements, when compared to controls. After controlling for executive difficulties, ALS patients still displayed significant difficulties on tasks that assessed their comprehension of both sarcastic and paradoxical sarcastic statements. The inability to read social cues and make social inferences has the potential to place significant strain on familial/interpersonal relationships in ALS. The findings of this study highlight the importance of employing a broader range of neuropsychological assessment tools to aid in early detection of frontal lobe impairment in non-demented ALS patients.

  14. Exploring sarcasm detection in amyotrophic lateral sclerosis using ecologically valid measures

    Science.gov (United States)

    Staios, Mathew; Fisher, Fiona; Lindell, Annukka K.; Ong, Ben; Howe, Jim; Reardon, Katrina

    2013-01-01

    Amyotrophic lateral sclerosis (ALS) is a rapidly progressive condition involving degeneration of both upper and lower motor neurons. Recent research suggests that a proportion of persons with ALS show a profile similar to that of frontotemporal dementia (FTD), with this group of ALS patients exhibiting social cognitive deficits. Although social cognitive deficits have been partially explored in ALS, research has yet to investigate such changes using ecologically valid measures. Therefore, this study aimed to further characterize the scope of social cognitive and emotion recognition deficits in non-demented ALS patients using an ecologically valid measure of social cognition. A sample of 35 ALS patients and 30 age-and-education matched controls were assessed using the Addenbrooke's Cognitive Examination, the Brixton Spatial Anticipation Test, and The Awareness of Social Inference Test, where participants were required to discriminate between various emotions and decipher socially challenging scenarios enacted in video vignettes. Participants with ALS showed significant difficulties in recognizing both sarcastic and paradoxical sarcastic statements, but not sincere statements, when compared to controls. After controlling for executive difficulties, ALS patients still displayed significant difficulties on tasks that assessed their comprehension of both sarcastic and paradoxical sarcastic statements. The inability to read social cues and make social inferences has the potential to place significant strain on familial/interpersonal relationships in ALS. The findings of this study highlight the importance of employing a broader range of neuropsychological assessment tools to aid in early detection of frontal lobe impairment in non-demented ALS patients. PMID:23734113

  15. The reliability of magnetic resonance imaging in traumatic brain injury lesion detection

    NARCIS (Netherlands)

    Geurts, B.H.J.; Andriessen, T.M.J.C.; Goraj, B.M.; Vos, P.E.

    2012-01-01

    Objective: This study compares inter-rater-reliability, lesion detection and clinical relevance of T2-weighted imaging (T2WI), Fluid Attenuated Inversion Recovery (FLAIR), T2*-gradient recalled echo (T2*-GRE) and Susceptibility Weighted Imaging (SWI) in Traumatic Brain Injury (TBI). Methods: Three

  16. Coordinating Center: Molecular and Cellular Findings of Screen-Detected Lesions | Division of Cancer Prevention

    Science.gov (United States)

    The Molecular and Cellular Characterization of Screen‐Detected Lesions ‐ Coordinating Center and Data Management Group will provide support for the participating studies responding to RFA CA14‐10. The coordinating center supports three main domains: network coordination, statistical support and computational analysis and protocol development and database support. Support for

  17. The spatial resolution of the porcine multifocal electroretinogram for detection of laser-induced retinal lesions

    DEFF Research Database (Denmark)

    Kyhn, Maria Voss; Kiilgaard, Jens Folke; Scherfig, Erik

    2008-01-01

    This study aimed to investigate the spatial resolution of a porcine multifocal electroretinogram (mfERG) protocol by testing its ability to detect laser-induced retinal lesions. Furthermore, we wanted to describe time-dependent changes in implicit time and amplitude of the different mfERG peaks...

  18. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  19. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    OpenAIRE

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guangqing; Cui, Xiaojing; Liang, Xian

    2015-01-01

    Purpose: The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. Methods: A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonog...

  20. Lesion detection in ultra-wide field retinal images for diabetic retinopathy diagnosis

    Science.gov (United States)

    Levenkova, Anastasia; Sowmya, Arcot; Kalloniatis, Michael; Ly, Angelica; Ho, Arthur

    2018-02-01

    Diabetic retinopathy (DR) leads to irreversible vision loss. Diagnosis and staging of DR is usually based on the presence, number, location and type of retinal lesions. Ultra-wide field (UWF) digital scanning laser technology provides an opportunity for computer-aided DR lesion detection. High-resolution UWF images (3078×2702 pixels) may allow detection of more clinically relevant retinopathy in comparison with conventional retinal images as UWF imaging covers a 200° retinal area, versus 45° by conventional cameras. Current approaches to DR diagnosis that analyze 7-field Early Treatment Diabetic Retinopathy Study (ETDRS) retinal images provide similar results to UWF imaging. However, in 40% of cases, more retinopathy was found outside the 7- field ETDRS fields by UWF and in 10% of cases, retinopathy was reclassified as more severe. The reason is that UWF images examine both the central retina and more peripheral regions. We propose an algorithm for automatic detection and classification of DR lesions such as cotton wool spots, exudates, microaneurysms and haemorrhages in UWF images. The algorithm uses convolutional neural network (CNN) as a feature extractor and classifies the feature vectors extracted from colour-composite UWF images using a support vector machine (SVM). The main contribution includes detection of four types of DR lesions in the peripheral retina for diagnostic purposes. The evaluation dataset contains 146 UWF images. The proposed method for detection of DR lesion subtypes in UWF images using two scenarios for transfer learning achieved AUC ≈ 80%. Data was split at the patient level to validate the proposed algorithm.

  1. Magnetic resonance imaging in clinically-definite multiple sclerosis

    International Nuclear Information System (INIS)

    Noakes, J.B.; Herkes, G.K.; Frith, J.A.

    1990-01-01

    Forty-two patients with clinically-definite multiple sclerosis were examined by magnetic resonance imaging using a 1.5-T instrument. Magnetic resonance imaging detected an abnormality in 90% of patients. In four patients, no lesions were demonstrated. The number, size and site of the lesions by magnetic resonance imaging were compared with the patients' clinical status and other variables. The Kurtzke disability status scale score increased in patients with corpus callosum atrophy, brainstem and basal ganglia lesions, and correlated with the total number of lesions. No correlation was shown between the findings of magnetic resonance imaging and disease duration, age, sex or pattern-reversal visual-evoked potentials. The variety of magnetic resonance images that could be obtained in patients with clinically-definite multiple sclerosis is highlighted. 24 refs., 8 figs., 1 tab

  2. Early Detection of Bone Lesions by Photoscanning with Radioactive Strontium-87m

    Energy Technology Data Exchange (ETDEWEB)

    Kostamis, P.; Constantinides, C.; Papavasiliou, C.; Binopoulos, D.; Sfontouris, J.; Malamos, B. [University of Athens Medical School, ' Alexandra' Hospital, Athens (Greece)

    1969-05-15

    Patients with proven and suspected bone lesions were scanned from 30 min to 3 h after an intravenous injection of 400 {mu}Ci to 1 mCi of {sup 87m}Sr. Many different types of bone tumours were detected, such as osteogenic sarcoma and metastatic cancer of breast, thyroid, lung and other organs. {sup 87m}Sr photoscanning easily demonstrates obvious tumours of the bone which have been visualized on the roentgenogram, but the most important purpose of the present study is the visualization of lesions which were not demonstrated on the conventional roentgenogram. The analysis of the examined cases is discussed. (author)

  3. The evaluation of the effect of attenuation correction on lesion detectability in whole-body FDG-PET

    International Nuclear Information System (INIS)

    Tomemori, Takashi; Uno, Kimiichi; Oka, Takashi; Suzuki, Takayuki; Tomiyoshi, Katsumi; Jin Wu

    2004-01-01

    The aim of this study was to compare the attenuation corrected and non-corrected FDG-PET images in patients with malignant lesions and to evaluate the effect of attenuation correction on lesion detectability. A total of 71 persons with 112 malignant lesions was examined. All subjects fasted for at least 4 hours before PET study and whole-body PET imaging was performed 45 min after the intravenous administration of FDG (mean dose: 273.8 MBq). Emission scans of 6 min and post-injection transmission scans of 6 min per bed position were used. The intensity of lesion uptake in FDG-PET image was visually classified into 3 grades; grade 2=the lesion was clearly identified in the maximum intensity projection (MIP) image of FDG-PET, grade 1=the lesion was not identified in MIP image but it can be identified in coronal image, grade 0=there was no contrast between lesion and background in both MIP and coronal image. Ninety-eight lesions (87.5%) were classified into same grade in both attenuation corrected and non-corrected image, but in 11 lesions (9.8%) attenuation corrected image was better lesion visualization than non-corrected image. All lesions divided between the primary lesions and the metastatic lesions. In 50 primary lesions, 43 lesions were depicted in both attenuation corrected and non-corrected image and other 7 lesions were not in both image. In 62 metastatic lesions, 50 lesions (80.7%) were classified into same grade in both attenuation corrected and non-corrected image, but in 10 lesions (16.1%) attenuation corrected image were better lesion visualization than non-corrected image. In the most cases, the lesions were depicted in both attenuation corrected and non-corrected image. In the primary lesions, the lesion detectability between attenuation corrected and non-corrected image was similar. But in some cases with the metastatic lesions, attenuation corrected image were better lesion visualization than non-corrected image. For asymptomatic patients, non

  4. The method for detecting small lesions in medical image based on sliding window

    Science.gov (United States)

    Han, Guilai; Jiao, Yuan

    2016-10-01

    At present, the research on computer-aided diagnosis includes the sample image segmentation, extracting visual features, generating the classification model by learning, and according to the model generated to classify and judge the inspected images. However, this method has a large scale of calculation and speed is slow. And because medical images are usually low contrast, when the traditional image segmentation method is applied to the medical image, there is a complete failure. As soon as possible to find the region of interest, improve detection speed, this topic attempts to introduce the current popular visual attention model into small lesions detection. However, Itti model is mainly for natural images. But the effect is not ideal when it is used to medical images which usually are gray images. Especially in the early stages of some cancers, the focus of a disease in the whole image is not the most significant region and sometimes is very difficult to be found. But these lesions are prominent in the local areas. This paper proposes a visual attention mechanism based on sliding window, and use sliding window to calculate the significance of a local area. Combined with the characteristics of the lesion, select the features of gray, entropy, corner and edge to generate a saliency map. Then the significant region is segmented and distinguished. This method reduces the difficulty of image segmentation, and improves the detection accuracy of small lesions, and it has great significance to early discovery, early diagnosis and treatment of cancers.

  5. Detection and classification of retinal lesions for grading of diabetic retinopathy.

    Science.gov (United States)

    Usman Akram, M; Khalid, Shehzad; Tariq, Anam; Khan, Shoab A; Azam, Farooque

    2014-02-01

    Diabetic Retinopathy (DR) is an eye abnormality in which the human retina is affected due to an increasing amount of insulin in blood. The early detection and diagnosis of DR is vital to save the vision of diabetes patients. The early signs of DR which appear on the surface of the retina are microaneurysms, haemorrhages, and exudates. In this paper, we propose a system consisting of a novel hybrid classifier for the detection of retinal lesions. The proposed system consists of preprocessing, extraction of candidate lesions, feature set formulation, and classification. In preprocessing, the system eliminates background pixels and extracts the blood vessels and optic disc from the digital retinal image. The candidate lesion detection phase extracts, using filter banks, all regions which may possibly have any type of lesion. A feature set based on different descriptors, such as shape, intensity, and statistics, is formulated for each possible candidate region: this further helps in classifying that region. This paper presents an extension of the m-Mediods based modeling approach, and combines it with a Gaussian Mixture Model in an ensemble to form a hybrid classifier to improve the accuracy of the classification. The proposed system is assessed using standard fundus image databases with the help of performance parameters, such as, sensitivity, specificity, accuracy, and the Receiver Operating Characteristics curves for statistical analysis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Effect of glatiramer acetate on conversion to clinically definite multiple sclerosis in patients with clinically isolated syndrome (PreCISe study): a randomised, double-blind, placebo-controlled trial

    DEFF Research Database (Denmark)

    Comi, G; Martinelli, V; Rodegher, M

    2009-01-01

    treatment with glatiramer acetate is efficacious in delaying conversion to clinically definite multiple sclerosis in patients presenting with clinically isolated syndrome and brain lesions detected by MRI. FUNDING: Teva Pharmaceutical Industries, Israel Udgivelsesdato: 2009/10/31......BACKGROUND: Glatiramer acetate, approved for the treatment of relapsing-remitting multiple sclerosis, reduces relapses and disease activity and burden monitored by MRI. We assessed the efficacy of early treatment with glatiramer acetate in delaying onset of clinically definite multiple sclerosis...

  7. Computerized detection method for asymptomatic white matter lesions in brain screening MR images using a clustering technique

    International Nuclear Information System (INIS)

    Kunieda, Takuya; Uchiyama, Yoshikazu; Hara, Takeshi

    2008-01-01

    Asymptomatic white matter lesions are frequently identified by the screening system known as Brain Dock, which is intended for the detection of asymptomatic brain diseases. The detection of asymptomatic white matter lesions is important because their presence is associated with an increased risk of stroke. Therefore, we have developed a computerized method for the detection of asymptomatic white matter lesions in order to assist radiologists in image interpretation as a ''second opinion''. Our database consisted of T 1 - and T 2 -weighted images obtained from 73 patients. The locations of the white matter lesions were determined by an experienced neuroradiologist. In order to restrict the area to be searched for white matter lesions, we first segmented the cerebral region in T 1 -weighted images by applying thresholding and region-growing techniques. To identify the initial candidate lesions, k-means clustering with pixel values in T 1 - and T 2 -weighted images was applied to the segmented cerebral region. To eliminate false positives (FPs), we determined the features, such as location, size, and circularity, of each of the initial candidate lesions. Finally, a rule-based scheme and a quadratic discriminant analysis with these features were employed to distinguish between white matter lesions and FPs. The results showed that the sensitivity for the detection of white matter lesions was 93.2%, with 4.3 FPs per image, suggesting that our computerized method may be useful for the detection of asymptomatic white matter lesions in T 1 - and T 2 -weighted images. (author)

  8. PET-CT detection rate of primary breast cancer lesions. Correlation with the clinicopathological factors

    International Nuclear Information System (INIS)

    Ogawa, Tomoko; Tozaki, Mitsuhiro; Fukuma, Eisuke

    2008-01-01

    One hundred and forty lesions of primary breast cancer underwent positron emission tomography (PET)-CT between June 2006 and May 2007. The PET-CT detection rate of primary breast cancer lesions was 72.1%. The detection rate was 52.1% for invasive cancer ≤20 mm, 92.8% for invasive breast cancers >20 mm, and these results were significant. In the present study, no significant relationship was observed between tumor types, however, invasive lobular carcinoma showed a lower detection rate, 58.3%. The PET-CT results were not significantly affected by either estrogen and progesterone receptors or distant metastasis. A significant correlation regarding the detection rate of PET-CT was found with HER2 status, tumor grade, and axillary lymph node status. The detection rate was 100% for invasive cancer ≤20 mm when the interval between prior diagnostic Mammotome biopsies and PET-CT was less than 3 weeks, 18.8% for invasive cancer ≤20 mm when the interval was more than 3 weeks, and these results were significant. Mammotome biopsies may therefore affect the detection rate of PET-CT. Invasive cancers ≤20 mm showed a low detection rate, therefore, it is considered to be insufficient to use PET-CT for the detection of early breast cancer. (author)

  9. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub [Yonsei University, Department of Radiology, Wonju College of Medicine, Wonju (Korea, Republic of); You, Joshua H. [Center for Health, Wellness, Fitness, Prevention, and Healing Across the Life Span, Department of Physical Therapy, Graduate School of Rehabilitation Science, Yonsei University, Center for Movement Impairment Solutions, Wonju City (Korea, Republic of); Lee, Ji Yong [Yonsei University, Department of Neurology, Wonju College of Medicine, Wonju (Korea, Republic of); Whang, Kum [Yonsei University, Department of Neurosurgery, Wonju College of Medicine, Wonju (Korea, Republic of)

    2010-12-15

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P < 0.01. There was no significant statistical difference in the accuracy (91.79% vs. 93.23% in regional cerebral blood volume; 92.26% vs. 95.31% in regional cerebral blood flow; 89.17% vs. 92.71% in mean transit time; 89.76% vs. 92.19% in time to peak; P > 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  10. Early detection of breast cancer mass lesions by mammogram segmentation images based on texture features

    International Nuclear Information System (INIS)

    Mahmood, F.H.

    2012-01-01

    Mammography is at present one of the available method for early detection of masses or abnormalities which is related to breast cancer.The calcifications. The challenge lies in early and accurate detection to overcome the development of breast cancer that affects more and more women throughout the world. Breast cancer is diagnosed at advanced stages with the help of the digital mammogram images. Masses appear in a mammogram as fine, granular clusters, which are often difficult to identify in a raw mammogram. The incidence of breast cancer in women has increased significantly in recent years. This paper proposes a computer aided diagnostic system for the extraction of features like mass lesions in mammograms for early detection of breast cancer. The proposed technique is based on a four-step procedure: (a) the preprocessing of the image is done, (b) regions of interest (ROI) specification, (c) supervised segmentation method includes two to stages performed using the minimum distance (M D) criterion, and (d) feature extraction based on Gray level Co-occurrence matrices GLC M for the identification of mass lesions. The method suggested for the detection of mass lesions from mammogram image segmentation and analysis was tested over several images taken from A L-llwiya Hospital in Baghdad, Iraq.The proposed technique shows better results.

  11. Multiple sclerosis - etiology and diagnostic potential.

    Science.gov (United States)

    Kamińska, Joanna; Koper, Olga M; Piechal, Kinga; Kemona, Halina

    2017-06-30

    Multiple sclerosis (MS) is a chronic inflammatory and demyelinating disease of autoimmune originate. The main agents responsible for the MS development include exogenous, environmental, and genetic factors. MS is characterized by multifocal and temporally scattered central nervous system (CNS) damage which lead to the axonal damage. Among clinical courses of MS it can be distinguish relapsing-remitting multiple sclerosis (RRMS), secondary progressive multiple sclerosis (SPSM), primary progressive multiple sclerosis (PPMS), and progressive-relapsing multiple sclerosis (RPMS). Depending on the severity of signs and symptoms MS can be described as benign MS or malignant MS. MS diagnosis is based on McDonald's diagnostic criteria, which link clinical manifestation with characteristic lesions demonstrated by magnetic resonance imaging (MRI), cerebrospinal fluid (CSF) analysis, and visual evoked potentials. Among CSF laboratory tests used to the MS diagnosis are applied: Tibbling & Link IgG index, reinbegrams, and CSF isoelectrofocusing for oligoclonal bands detection. It should be emphasized, that despite huge progress regarding MS as well as the availability of different diagnostics methods this disease is still a diagnostic challenge. It may result from fact that MS has diverse clinical course and there is a lack of single test, which would be of appropriate diagnostic sensitivity and specificity for quick and accurate diagnosis.

  12. Multiple sclerosis - etiology and diagnostic potential

    Directory of Open Access Journals (Sweden)

    Joanna Kamińska

    2017-06-01

    Full Text Available Multiple sclerosis (MS is a chronic inflammatory and demyelinating disease of autoimmune originate. The main agents responsible for the MS development include exogenous, environmental, and genetic factors. MS is characterized by multifocal and temporally scattered central nervous system (CNS damage which lead to the axonal damage. Among clinical courses of MS it can be distinguish relapsing-remitting multiple sclerosis (RRMS, secondary progressive multiple sclerosis (SPSM, primary progressive multiple sclerosis (PPMS, and progressive-relapsing multiple sclerosis (RPMS. Depending on the severity of signs and symptoms MS can be described as benign MS or malignant MS. MS diagnosis is based on McDonald’s diagnostic criteria, which link clinical manifestation with characteristic lesions demonstrated by magnetic resonance imaging (MRI, cerebrospinal fluid (CSF analysis, and visual evoked potentials. Among CSF laboratory tests used to the MS diagnosis are applied: Tibbling & Link IgG index, reinbegrams, and CSF isoelectrofocusing for oligoclonal bands detection. It should be emphasized, that despite huge progress regarding MS as well as the availability of differentdiagnostics methods this disease is still a diagnostic challenge. It may result from fact that MS has diverse clinical course and there is a lack of single test, which would be of appropriate diagnostic sensitivity and specificity for quick and accurate diagnosis.

  13. The diagnosis of multiple sclerosis

    International Nuclear Information System (INIS)

    Sanders, E.A.C.M.

    1982-01-01

    This thesis describes recently developed research methods for the diagnosis of multiple sclerosis. In Chapter X the use of the CT-scan in the detection of hemispheral or cerebellar lesions is discussed. In chapter XIII the results of the application of all methods to a group of 89 patients with definite, probable or possible multiple sclerosis and to a group of 25 purely optic neuritis patients are presented. With the aid of the CT-scan, hypo- or hyperdense areas in the white matter of the cerebral hemispheres were found in 52% of the 114 patients. Most reports ascribe these lesions to demyelinating cerebral plaques. The CT-scan showed no cerebellar or brainstem lesions. The CT-scan is independent of the duration of, and degree of incapacitation due to, the disease and can be helpful in giving a definite diagnosis in an early stage of the disease. The CT-scan will always play an important role for the differential diagnosis. (Auth.)

  14. CT of multiple sclerosis: reassessment of delayed scanning with high doses of contrast material

    International Nuclear Information System (INIS)

    Spiegel, S.M.; Vinuela, F.; Fox, A.J.; Pelz, D.M.

    1985-01-01

    A prospective study involving 87 patients was carried out to evaluate the necessity for a high dose of contrast material in addition to delayed computed tomographic (CT) scanning for optimal detection of the lesions of multiple sclerosis in the brain. In patients with either clinically definite multiple sclerosis or laboratory-supported definite multiple sclerosis, CT scans were obtained with a uniform protocol. Lesions consistent with multiple sclerosis were demonstrated on the second scan in 54 patients. In 36 of these 54 patients, the high-dose delayed scan added information. These results are quite similar to those of a previous study from this institution using different patients, in whom the second scan was obtained immediately after the bolus injection of contrast material containing 40 g of organically bound iodine. The lack of real difference in the results of the two studies indicate that the increased dose, not just the delay in scanning, is necessary for a proper study

  15. Lesion detection and vascular assessment with modified CTAP and MR imaging of liver

    International Nuclear Information System (INIS)

    Thoeni, R.F.; Werthmuller, W.C.; Warren, R.S.; Mulvihill, S.J.

    1990-01-01

    This paper reports on a special CT arterial portography (CTAP) method with immediate and delayed scans compared to MR imaging of liver with fat-saturation images and angiographic portogram to determine whether CTAP and MR imaging could obviate the angiographic portogram and which imaging method best detects lesions. In 13 patients, CTAP was obtained on a FASTRAK CT scanner in an immediate and delayed dynamic mode with 0.4-sec sections. These CT results were compared to the angiographic portogram and MR results of T1-weighted SR (TR 300, TE 20, NEX 4) and T2-weighted SE (TR 2,000--2,500; TE 20/70; NEX 2) W=with and without fat saturation. CT/MR features analyzed included lesion detection, involvement of portal and hepatic veins, and adenopathy. Features were ranked from 0 = definitely normal to 4 = definitely abnormal

  16. Oral precancerous lesions: Problems of early detection and oral cancer prevention

    Science.gov (United States)

    Gileva, Olga S.; Libik, Tatiana V.; Danilov, Konstantin V.

    2016-08-01

    The study presents the results of the research in the structure, local and systemic risk factors, peculiarities of the clinical manifestation, and quality of primary diagnosis of precancerous oral mucosa lesions (OMLs). In the study a wide range of OMLs and high (25.4%) proportion of oral precancerous lesions (OPLs) in their structure was indicated. The high percentage of different diagnostic errors and the lack of oncological awareness of dental practitioners, as well as the sharp necessity of inclusion of precancer/cancer early detection techniques into their daily practice were noted. The effectiveness of chemilumenescence system of early OPLs and oral cancer detection was demonstrated, the prospects of infrared thermography as a diagnostic tool were also discussed.

  17. Treatment of multiple sclerosis relapses with high-dose methylprednisolone reduces the evolution of contrast-enhancing lesions into persistent black holes.

    Science.gov (United States)

    Di Gregorio, Maria; Gaetani, Lorenzo; Eusebi, Paolo; Floridi, Piero; Picchioni, Antonella; Rosi, Giovanni; Mancini, Andrea; Floridi, Chiara; Baschieri, Francesca; Gentili, Lucia; Sarchielli, Paola; Calabresi, Paolo; Di Filippo, Massimiliano

    2018-03-01

    The MRI evidence of persistent black holes (pBHs) on T1-weighted images reflects brain tissue loss in multiple sclerosis (MS). The evolution of contrast-enhancing lesions (CELs) into pBHs probably depends on the degree and persistence of focal brain inflammation. The aim of our retrospective study was to evaluate the effect of a single cycle of intravenous methylprednisolone (IVMP), as for MS relapse treatment, on the risk of CELs' evolution into pBHs. We selected 57 patients with CELs on the baseline MRI scan. We evaluated the evolution of CELs into pBHs on a follow-up MRI scan performed after ≥ 6 months in patients exposed and not exposed to IVMP for the treatment of relapse after the baseline MRI. In our cohort, 182 CELs were identified in the baseline MRI and 57 of them (31.3%) evolved into pBHs. In the multivariate analysis, the exposure of CELs to IVMP resulted to be a significant independent protective factor against pBHs' formation (OR 0.28, 95% CI 0.11-0.766, p = 0.005), while ring enhancement pattern and the fact of being symptomatic were significant risk factors for CELs' conversion into pBHs (OR 6.42, 95% CI 2.55-17.27, p < 0.001 and OR 13.19, 95% CI 1.56-288.87, p = 0.037). The exposure of CELs to a cycle of IVMP as for relapse treatment is associated with a lower risk of CELs' evolution into pBHs. Future studies are required to confirm the potential independent protective effect of IVMP on CELs' evolution into pBHs.

  18. Fast spine echo and fast fluid attenuated inversion recovery sequences in multiple sclerosis

    International Nuclear Information System (INIS)

    Paolillo, Andrea; Giugni, Elisabetta; Bozzao, Alessandro; Bastianello, Stefano

    1997-01-01

    Fast spin echo (FSE) and fast fluid attenuated inversion recovery (fast-FLAIR) sequences, were compared with conventional spin echo (CSE) in quantitating multiple sclerosis (MS) lesion burden. For each sequence, the total number and volume of MS lesions were calculated in 38 remitting multiple sclerosis patients using a semiautomated lesion detection program. Conventional spin echo, fast spin echo, and fast fluid attenuated inversion recovery image were reported on randomly and at different times by two expert observers. Interobserver differences, the time needed to quantitative multiple sclerosis lesions and lesion signal intensity (contrast-to-noise ratio and overall contrast) were considered. The lesions were classified by site into infratentorial, white matter and cortical/subcortical. A total of 2970 lesions with a volume of 961.7 cm 3 was calculated on conventional spin echo images. Fast spin echo images depicted fewer (16.6%; p < .005) and smaller (24.9%; p < .0001) lesions and the differences were statistically significant. Despite an overall nonsignificant reduction for fast-FLAIR images (-5% and 4.8% for lesion number and volume, respectively), significantly lower values (lesion number: p < 0.1; volume: p < .04)were observed for infratentorial lesions, while significantly higher values were seen for cortical/subcortical lesions (lesion number: p < .01; volume: p < .02). A higher lesion/white matter contrast (p < .002), a significant time saving for lesion burden quantitation (p < .05) and very low interobserver variability were found in favor of fast-FLAIR. Our data suggest that, despite the limitations regarding infratentorial lesions, fast-FLAIR sequences are indicated in R studies because of their good identification of cortical/subcortical lesions, almost complete interobserver agreement, higher contrast-to-noise ratio and limited time needed for semiautomated quantitation

  19. Novel fMRI working memory paradigm accurately detects cognitive impairment in Multiple Sclerosis

    Science.gov (United States)

    Nelson, Flavia; Akhtar, Mohammad A.; Zúñiga, Edward; Perez, Carlos A.; Hasan, Khader M.; Wilken, Jeffrey; Wolinsky, Jerry S.; Narayana, Ponnada A.; Steinberg, Joel L.

    2016-01-01

    Background Cognitive impairment (CI) cannot be diagnosed by MRI. Functional MRI (fMRI) paradigms such as the immediate/delayed memory task (I/DMT), detect varying degrees of working memory. Preliminary findings using I/DMT, showed differences in Blood Oxygenation Level Dependent (BOLD) activation between impaired (MSCI, n=12) and non-impaired (MSNI, n=9) MS patients. Objectives To confirm CI detection based on I/DMT’ BOLD activation in a larger cohort of MS patients. The role of T2 lesion volume (LV) and EDSS in magnitude of BOLD signal were also sought. Methods Fifty patients [EDSS mean (m) = 3.2, DD m =12 yr., age m =40yr.] underwent the Minimal Assessment of Cognitive Function in MS (MACFIMS) and the I/DMT. Working-memory activation (WMa) represents BOLD signal during DMT minus signal during IMT. CI was based on MACFIMS. Results 10 MSNI, 30 MSCI and 4 borderline patients were included in analyses. ANOVA showed MSNI had significantly greater WMa than MSCI, in the left (L) prefrontal cortex and L supplementary motor area (p = 0.032). Regression analysis showed significant inverse correlations between WMa and T2 LV/EDSS in similar areas (p = 0.005, 0.004 respectively). Conclusion I/DMT-based BOLD activation detects CI in MS, larger studies are needed to confirm these findings. PMID:27613119

  20. Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions

    International Nuclear Information System (INIS)

    Xu, Yonghua; Cai, Wenli; Nappi, Janne; Yoshida, Hiro

    2012-01-01

    Purpose: To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (2D). Materials and methods: Forty CTC cases with flat lesions were retrospectively observed. The Subjects from a multicenter clinical trial underwent cathartic bowel preparation with orally administrated barium-based fecal-tagging. Sixty-nine flat lesions were confirmed using colonoscopy and histopathology as a reference standard. The results from SAEC reading were compared with those of prospective V3D and 2D readings. Results: Overall detection sensitivity with SAEC was 52% (36/69), which was statistically higher than that of 32% (22/69) and 29% (20/69) with V3D and 2D readings, respectively (p < 0.05). The sensitivities in detecting not-on-fold flat lesions were 63% (24/38), 45% (17/38), and 42% (16/38) with SAEC, V3D, and 2D readings, respectively; whereas those of on-fold flat lesions were 39% (12/31), 16% (5/31), and 13% (4/31), respectively. None of the eight flat lesions (2-9 mm) at cecum was detected by any of the three reading methods. Excluding the flat lesions at cecum, the sensitivity with SAEC for detecting flat lesion ≥4 mm increased to 84% (31/37). Conclusions: The fecal-tagging CTC with structure-analysis electronic cleansing could yield a high sensitivity for detecting flat lesions ≥4 mm. The not-on-fold flat lesions were detected with higher sensitivity than on-fold flat lesions.

  1. Automatic detection and recognition of multiple macular lesions in retinal optical coherence tomography images with multi-instance multilabel learning

    Science.gov (United States)

    Fang, Leyuan; Yang, Liumao; Li, Shutao; Rabbani, Hossein; Liu, Zhimin; Peng, Qinghua; Chen, Xiangdong

    2017-06-01

    Detection and recognition of macular lesions in optical coherence tomography (OCT) are very important for retinal diseases diagnosis and treatment. As one kind of retinal disease (e.g., diabetic retinopathy) may contain multiple lesions (e.g., edema, exudates, and microaneurysms) and eye patients may suffer from multiple retinal diseases, multiple lesions often coexist within one retinal image. Therefore, one single-lesion-based detector may not support the diagnosis of clinical eye diseases. To address this issue, we propose a multi-instance multilabel-based lesions recognition (MIML-LR) method for the simultaneous detection and recognition of multiple lesions. The proposed MIML-LR method consists of the following steps: (1) segment the regions of interest (ROIs) for different lesions, (2) compute descriptive instances (features) for each lesion region, (3) construct multilabel detectors, and (4) recognize each ROI with the detectors. The proposed MIML-LR method was tested on 823 clinically labeled OCT images with normal macular and macular with three common lesions: epiretinal membrane, edema, and drusen. For each input OCT image, our MIML-LR method can automatically identify the number of lesions and assign the class labels, achieving the average accuracy of 88.72% for the cases with multiple lesions, which better assists macular disease diagnosis and treatment.

  2. An Optimized Clustering Approach for Automated Detection of White Matter Lesions in MRI Brain Images

    Directory of Open Access Journals (Sweden)

    M. Anitha

    2012-04-01

    Full Text Available Settings White Matter lesions (WMLs are small areas of dead cells found in parts of the brain. In general, it is difficult for medical experts to accurately quantify the WMLs due to decreased contrast between White Matter (WM and Grey Matter (GM. The aim of this paper is to
    automatically detect the White Matter Lesions which is present in the brains of elderly people. WML detection process includes the following stages: 1. Image preprocessing, 2. Clustering (Fuzzy c-means clustering, Geostatistical Possibilistic clustering and Geostatistical Fuzzy clustering and 3.Optimization using Particle Swarm Optimization (PSO. The proposed system is tested on a database of 208 MRI images. GFCM yields high sensitivity of 89%, specificity of 94% and overall accuracy of 93% over FCM and GPC. The clustered brain images are then subjected to Particle Swarm Optimization (PSO. The optimized result obtained from GFCM-PSO provides sensitivity of 90%, specificity of 94% and accuracy of 95%. The detection results reveals that GFCM and GFCMPSO better localizes the large regions of lesions and gives less false positive rate when compared to GPC and GPC-PSO which captures the largest loads of WMLs only in the upper ventral horns of the brain.

  3. Scintigraphic detection of peptic lesions with the method of radiolabelled sucralfate

    International Nuclear Information System (INIS)

    Naumovski, J.; Kovkarova, E.; Simova, N.; Janevik-Ivanovska, E.; Georgievska- Kuzmanovska, S.

    2003-01-01

    Background. Sucralfate is an antiulcer agent that after peroral application strongly adheres to mucosal defects and in that way provides a protective barrier to further damage from acid and pepsin. If radiolabelled with a gamma isotope, it could be detected under a gamma camera pointing lesions to which it adhered. With the aim to confirm a suitable noninvasive method for investigation of caustic lesions of the upper gastrointestinal tract we evaluated in a preliminary study the validity of the radiolabelled Sucralfate scintigraphy in detection of peptic disease. Patients and methods. With that purpose, 35 patients after an endoscopic examination underwent scintigraphy with Tc-99m-DTPA sucralfate. Patients were divided in two groups: a group of 20 patients with endoscopic confirmed peptic disease and a control group of 15 persons who had not any disease of the upper gastrointestinal tract. Results. Using the test for clinical evaluation of a new method, the scan showed sensitivity of 75 %, specificity of 100 % and accuracy of 85.7 %. Conclusions. Scintigraphy with Tc-99m-DTPA Sucralfate promoting it as an additional method, complementary to routine investigations in detecting mucosal lesions. (author)

  4. Improved focal liver lesion detection by increasing flip angle during gadoxetic acid-enhancement in MRI

    International Nuclear Information System (INIS)

    Lee, Se Jy; Kim, Young Keun

    2015-01-01

    To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)’s enhanced MR imaging with a flip angle (FA) of 30° compared with a 11°. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA 11° and 30° images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA 30° images was found to be superior than FA 11°, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA 30° image(p<0.05) was better than FA 11° therefore, the FA 30° improves the focal liver lesion detection. FA 30° of MR image can detect liver lesion more sensitively than the existing FA11° image after GA contrast enhancement at 15 minute time point

  5. Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening.

    Science.gov (United States)

    Seoud, Lama; Hurtut, Thomas; Chelbi, Jihed; Cheriet, Farida; Langlois, J M Pierre

    2016-04-01

    The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and validated. The main contribution is a new set of shape features, called Dynamic Shape Features, that do not require precise segmentation of the regions to be classified. These features represent the evolution of the shape during image flooding and allow to discriminate between lesions and vessel segments. The method is validated per-lesion and per-image using six databases, four of which are publicly available. It proves to be robust with respect to variability in image resolution, quality and acquisition system. On the Retinopathy Online Challenge's database, the method achieves a FROC score of 0.420 which ranks it fourth. On the Messidor database, when detecting images with diabetic retinopathy, the proposed method achieves an area under the ROC curve of 0.899, comparable to the score of human experts, and it outperforms state-of-the-art approaches.

  6. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    Energy Technology Data Exchange (ETDEWEB)

    Morais, A. P. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Salgado de Oliveira University, Marechal Deodoro Street, 217 – Centro, Niterói, Rio de Janeiro (Brazil); Pino, A. V. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Souza, M. N. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Electronics Department at Polytechnic School, Federal University of Rio de Janeiro, Centro de Tecnologia Bloco H sala 217, Ilha do Fundão, Rio de Janeiro (Brazil)

    2016-08-15

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

  7. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    International Nuclear Information System (INIS)

    Morais, A. P.; Pino, A. V.; Souza, M. N.

    2016-01-01

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

  8. Role of Visual Inspection of Cervix with Acetic Acid (VIA in Detecting Precancerous Lesions of Cervix

    Directory of Open Access Journals (Sweden)

    Kamrun Nessa

    2014-01-01

    Full Text Available Background: Carcinoma of cervix is the most common malignancy in female and a major public health problem worldwide. It is the leading cause of death from cancer among women in low resource settings. In Bangladesh, mortality rate is high as most of the cases with cervical cancer are diagnosed in advanced stage. World Health Organization considers cervical cancer as a preventable disease as it can be identified in preinvasive stage. Considerable efforts have been given in detection and treatment of the condition all over the world. A number of cervical cancer screening tests are available. Among them, visual inspection of cervix with acetic acid is rational and can be competently performed by physicians with proper training. Objective: To find out the feasibility of the visual inspection of cervix with acetic acid for the detection of the precancerous lesions of the cervix in our country. Materials and Methods: This cross sectional, analytical study was carried out among the patients attending the outpatient department of Bangabandhu Sheikh Mujib Medical University (BSMMU who were VIA positive and sent for colposcopy in the colposcopy clinic in the department of Obstetrics and Gynecology in BSMMU from June to December 2004. Two hundred samples were considered for this study. Results: Out of 200 cases, colposcopically 85% had CIN and invasive lesions, 4% had inflammatory lesions while 11% had normal findings. Colposcopy directed punch biopsy revealed positive lesions in 81%, 4% had inflammatory lesions while 15% had normal findings. Conclusion: The study concluded that VIA and colposcopy are the important methods in the evaluation of cervical premalignancy. VIA may be an important tool for screening of cervical cancer in low resource settings as it is simple, easy to perform and cost-effective. After screening, VIA positive cases must be referred for colposcopic evaluation. We can screen cervical cancer by VIA all over the country and thus reduce

  9. Random forest learning of ultrasonic statistical physics and object spaces for lesion detection in 2D sonomammography

    Science.gov (United States)

    Sheet, Debdoot; Karamalis, Athanasios; Kraft, Silvan; Noël, Peter B.; Vag, Tibor; Sadhu, Anup; Katouzian, Amin; Navab, Nassir; Chatterjee, Jyotirmoy; Ray, Ajoy K.

    2013-03-01

    Breast cancer is the most common form of cancer in women. Early diagnosis can significantly improve lifeexpectancy and allow different treatment options. Clinicians favor 2D ultrasonography for breast tissue abnormality screening due to high sensitivity and specificity compared to competing technologies. However, inter- and intra-observer variability in visual assessment and reporting of lesions often handicaps its performance. Existing Computer Assisted Diagnosis (CAD) systems though being able to detect solid lesions are often restricted in performance. These restrictions are inability to (1) detect lesion of multiple sizes and shapes, and (2) differentiate between hypo-echoic lesions from their posterior acoustic shadowing. In this work we present a completely automatic system for detection and segmentation of breast lesions in 2D ultrasound images. We employ random forests for learning of tissue specific primal to discriminate breast lesions from surrounding normal tissues. This enables it to detect lesions of multiple shapes and sizes, as well as discriminate between hypo-echoic lesion from associated posterior acoustic shadowing. The primal comprises of (i) multiscale estimated ultrasonic statistical physics and (ii) scale-space characteristics. The random forest learns lesion vs. background primal from a database of 2D ultrasound images with labeled lesions. For segmentation, the posterior probabilities of lesion pixels estimated by the learnt random forest are hard thresholded to provide a random walks segmentation stage with starting seeds. Our method achieves detection with 99.19% accuracy and segmentation with mean contour-to-contour error < 3 pixels on a set of 40 images with 49 lesions.

  10. Assessment of the breath motion correction on the detectability of lesions in PET oncology

    International Nuclear Information System (INIS)

    Marache-Francisco, S.

    2012-02-01

    Positron emission tomography (PET) is a nuclear medicine imaging technique that produces a three-dimensional image of functional processes in the body. The system detects pairs of gamma rays emitted by a tracer, which is introduced into the body. Three-dimensional images of tracer concentration within the body are then constructed by computer analysis. Respiratory motion in emission tomography leads to image blurring especially in the lower thorax and the upper abdomen, influencing this way the quantitative accuracy of PET measurements as well as leading to a loss of sensitivity in lesion detection. Although PET exams are getting shorter thanks to the improvement of scanner sensitivity, the current 2-3 minutes acquisitions per bed position are not yet compatible with patient breath-holding. Performing accurate respiratory motion correction without impairing the standard clinical protocol, i.e. without increasing the acquisition time, thus remains challenging. Different types of respiratory motion correction approaches have been proposed, mostly based on the use of non-rigid deformation fields either applied to the gated PET images or integrated during an iterative reconstruction algorithm. Evaluation of theses methods has been mainly focusing on the quantification and localization accuracy of small lesions, but their impact on the clinician detection performance during the diagnostic task has not been fully investigated yet. The purpose of this study is to address this question based on a computer assisted detection study. We evaluate the influence of two motion correction methods on the detection of small lesions in human oncology FDG PET images. This study is based on a series of realistic simulated whole-body FDG images based on the XCAT model. Detection performance is evaluated with a computer-aided detection system that we are developing for whole-body PET/CT images. Detection performances achieved with these two correction methods are compared with those

  11. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Svenmarker, Pontus; Tidemand-Lichtenberg, Peter

    2010-01-01

    signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image......We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-to-noise ratio to be achieved in the resulting autofluorescence...

  12. Natalizumab remains detectable in patients with multiple sclerosis long after treatment is stopped

    NARCIS (Netherlands)

    Rispens, Theo; Vennegoor, Anke; Wolbink, Gert Jan; Polman, Chris H.; Killestein, Joep

    2012-01-01

    Natalizumab is frequently used as a treatment for multiple sclerosis (MS). The occurrence of progressive multifocal leukoencephalopathy (PML) in natalizumab-treated patients indicates that its prominent beneficial effects need to be balanced against the risks. Also, cessation of the drug seems to be

  13. Detection of early lung cancer lesions in surgical resections and in bronchial and transbronchial biopsies

    International Nuclear Information System (INIS)

    Rott, T.; Jerse, M.; Tercelj, M.; Erzen, J.

    2006-01-01

    Background. Overall bad prognosis of lung cancer is mostly due to too late detection of early lung cancer, which may be treated with good success. Therefore, different diagnostic methods are developing for more efficient detection of early lung cancer: besides modern radiological, bronchoscopic methods with additional fluorescence techniques, quantitative cytological investigations, also histological and molecular investigations are included. Histology may reveal early preinvasive lung cancer lesions, associated early during multistep lung carcinogenesis with molecular genetic changes. Patients and methods. Preinvasive epithelial lung cancer lesions we searched in two groups of patients. In the first group of 316 patients from the period March 2003 - August 2006, 498 bronchial and transbronchial biopsies were examined for squamous metaplasia and dysplasia, carcinoma in situ, and invasive tumours. In the second group of 238 patients from the period January 2004 - August 2006, resected primary lung tumours were analysed for preinvasive and invasive neuroendocrine tumours and atypical adenomatous hyperplasia. Results. The most frequent changes in bronchial and transbronchial biopsies were squamous metaplasia (46.5%), simple or goblet cell hyperplasia of the bronchial epithelium (44.3%), malignant tumours (20.66%) and squamous dysplasia (16.1%), but rare carcinoma in situ (0.63%). Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia was found in 15 (6.3%) cases in the vicinity of 238 resected lung cancer specimens, carcinoid in 12 patients (5%), and mostly combined large cell neuroendocrine cancer in 21 patients (8.8%). Atypical adenomatous hyperplasia was found in 2 patients. Conclusions. Classical histological analysis should be focused on detection of early preinvasive epithelial lung cancer lesions. Additional available molecular investigations may reveal gradual genetic changes characteristic for a series of the preinvasive epithelial histological changes

  14. Pigmented skin lesion detection using random forest and wavelet-based texture

    Science.gov (United States)

    Hu, Ping; Yang, Tie-jun

    2016-10-01

    The incidence of cutaneous malignant melanoma, a disease of worldwide distribution and is the deadliest form of skin cancer, has been rapidly increasing over the last few decades. Because advanced cutaneous melanoma is still incurable, early detection is an important step toward a reduction in mortality. Dermoscopy photographs are commonly used in melanoma diagnosis and can capture detailed features of a lesion. A great variability exists in the visual appearance of pigmented skin lesions. Therefore, in order to minimize the diagnostic errors that result from the difficulty and subjectivity of visual interpretation, an automatic detection approach is required. The objectives of this paper were to propose a hybrid method using random forest and Gabor wavelet transformation to accurately differentiate which part belong to lesion area and the other is not in a dermoscopy photographs and analyze segmentation accuracy. A random forest classifier consisting of a set of decision trees was used for classification. Gabor wavelets transformation are the mathematical model of visual cortical cells of mammalian brain and an image can be decomposed into multiple scales and multiple orientations by using it. The Gabor function has been recognized as a very useful tool in texture analysis, due to its optimal localization properties in both spatial and frequency domain. Texture features based on Gabor wavelets transformation are found by the Gabor filtered image. Experiment results indicate the following: (1) the proposed algorithm based on random forest outperformed the-state-of-the-art in pigmented skin lesions detection (2) and the inclusion of Gabor wavelet transformation based texture features improved segmentation accuracy significantly.

  15. Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Samei, Ehsan; Saunders, Robert; Abbey, Craig; Delong, David

    2007-01-01

    The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original mammograms. The mammograms were converted into luminance values corresponding to those displayed on a clinical soft-copy display station and subsequently analyzed by Laguerre-Gauss and Gabor channelized Hotelling observer models for differences in detectability performance with reduction in radiation dose. Performance was measured under a signal known exactly but variable detection task paradigm in terms of receiver operating characteristics (ROC) curves and area under the ROC curves. The results suggested that luminance mapping of digital mammograms affects performance of model observers. Reduction in dose levels by 50% lowered the detectability of masses with borderline statistical significance. Dose reduction did not have a statistically significant effect on detection of microcalcifications. The model results indicate that there is room for optimization of dose level in mammographic screening procedures

  16. Frequent Detection of Pancreatic Lesions in Asymptomatic High-Risk Individuals

    Science.gov (United States)

    Canto, Marcia Irene; Hruban, Ralph H.; Fishman, Elliot K.; Kamel, Ihab R.; Schulick, Richard; Zhang, Zhe; Topazian, Mark; Takahashi, Naoki; Fletcher, Joel; Petersen, Gloria; Klein, Alison P.; Axilbund, Jennifer; Griffin, Constance; Syngal, Sapna; Saltzman, John R.; Mortele, Koenraad J.; Lee, Jeffrey; Tamm, Eric; Vikram, Raghunandan; Bhosale, Priya; Margolis, Daniel; Farrell, James; Goggins, Michael

    2012-01-01

    BACKGROUND & AIMS The risk of pancreatic cancer is increased in patients with a strong family history of pancreatic cancer or a predisposing germline mutation. Screening can detect curable, non-invasive pancreatic neoplasms, but the optimal imaging approach is not known. We determined the baseline prevalence and characteristics of pancreatic abnormalities using 3 imaging tests to screen asymptomatic, high-risk individuals (HRI). METHODS We screened 225 asymptomatic adult HRI at 5 academic US medical centers once, using computed tomography (CT), magnetic resonance imaging (MRI), and endoscopic ultrasonography (EUS). We compared results in a blinded, independent fashion. RESULTS Ninety-two of 216 HRI (42%) were found to have at least 1 pancreatic mass (84 cystic, 3 solid) or a dilated pancreatic duct (n=5) by any of the imaging modalities. Fifty-one of the 84 HRI with a cyst (60.7%) had multiple lesions, typically small (mean 0.55 cm, range 2–39 mm), in multiple locations. The prevalence of pancreatic lesions increased with age; they were detected in 14% of subjects <50 years old, 34% of subjects 50–59 years old, and 53% of subjects 60–69 years old (P<.0001). CT, MRI, and EUS detected a pancreatic abnormality in 11%, 33.3%, and 42.6% of the HRI, respectively. Among these abnormalities, proven or suspected neoplasms were identified in 85 HRI (82 intraductal papillary mucinous neoplasms [IPMN] and 3 pancreatic endocrine tumors). Three of 5 HRI who underwent pancreatic resection had high-grade dysplasia in <3 cm IPMNs and in multiple intraepithelial neoplasias. CONCLUSIONS Screening of asymptomatic HRI frequently detects small pancreatic cysts, including curable, non-invasive high-grade neoplasms. EUS and MRI detect pancreatic lesions better than CT. PMID:22245846

  17. Lesion detection and quantification performance of the Tachyon-I time-of-flight PET scanner: phantom and human studies

    Science.gov (United States)

    Zhang, Xuezhu; Peng, Qiyu; Zhou, Jian; Huber, Jennifer S.; Moses, William W.; Qi, Jinyi

    2018-03-01

    The first generation Tachyon PET (Tachyon-I) is a demonstration single-ring PET scanner that reaches a coincidence timing resolution of 314 ps using LSO scintillator crystals coupled to conventional photomultiplier tubes. The objective of this study was to quantify the improvement in both lesion detection and quantification performance resulting from the improved time-of-flight (TOF) capability of the Tachyon-I scanner. We developed a quantitative TOF image reconstruction method for the Tachyon-I and evaluated its TOF gain for lesion detection and quantification. Scans of either a standard NEMA torso phantom or healthy volunteers were used as the normal background data. Separately scanned point source and sphere data were superimposed onto the phantom or human data after accounting for the object attenuation. We used the bootstrap method to generate multiple independent noisy datasets with and without a lesion present. The signal-to-noise ratio (SNR) of a channelized hotelling observer (CHO) was calculated for each lesion size and location combination to evaluate the lesion detection performance. The bias versus standard deviation trade-off of each lesion uptake was also calculated to evaluate the quantification performance. The resulting CHO-SNR measurements showed improved performance in lesion detection with better timing resolution. The detection performance was also dependent on the lesion size and location, in addition to the background object size and shape. The results of bias versus noise trade-off showed that the noise (standard deviation) reduction ratio was about 1.1–1.3 over the TOF 500 ps and 1.5–1.9 over the non-TOF modes, similar to the SNR gains for lesion detection. In conclusion, this Tachyon-I PET study demonstrated the benefit of improved time-of-flight capability on lesion detection and ROI quantification for both phantom and human subjects.

  18. Lesion detection performance: comparative analysis of low-dose CT data of the chest on two hybrid imaging systems.

    Science.gov (United States)

    Jessop, Maryam; Thompson, John D; Coward, Joanne; Sanderud, Audun; Jorge, José; de Groot, Martijn; Lança, Luís; Hogg, Peter

    2015-03-01

    Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). JAFROC analysis showed a significant difference (P detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified. © 2015 by the Society of Nuclear Medicine and Molecular Imaging

  19. Improved detection reveals active β-papillomavirus infection in skin lesions from kidney transplant recipients.

    Science.gov (United States)

    Borgogna, Cinzia; Lanfredini, Simone; Peretti, Alberto; De Andrea, Marco; Zavattaro, Elisa; Colombo, Enrico; Quaglia, Marco; Boldorini, Renzo; Miglio, Umberto; Doorbar, John; Bavinck, Jan N Bouwes; Quint, Koen D; de Koning, Maurits N C; Landolfo, Santo; Gariglio, Marisa

    2014-08-01

    The aim of this study was to determine whether detection of β-HPV gene products, as defined in epidermodysplasia verruciformis skin cancer, could also be observed in lesions from kidney transplant recipients alongside the viral DNA. A total of 111 samples, corresponding to 79 skin lesions abscised from 17 kidney transplant recipients, have been analyzed. The initial PCR analysis demonstrated that β-HPV-DNA was highly present in our tumor series (85%). Using a combination of antibodies raised against the E4 and L1 proteins of the β-genotypes, we were able to visualize productive infection in 4 out of 19 actinic keratoses, and in the pathological borders of 1 out of 14 squamous cell carcinomas and 1 out of 31 basal cell carcinomas. Increased expression of the cellular proliferation marker minichromosome maintenance protein 7 (MCM7), that extended into the upper epithelial layers, was a common feature of all the E4-positive areas, indicating that cells were driven into the cell cycle in areas of productive viral infections. Although the present study does not directly demonstrate a causal role of these viruses, the detection of E4 and L1 positivity in actinic keratosis and the adjacent pathological epithelium of skin cancer, clearly shows that β-HPV are actively replicating in the intraepidermal precursor lesions of kidney transplant recipients and can therefore cooperate with other carcinogenic agents, such as UVB, favoring skin cancer promotion.

  20. Fast approach to evaluate MAP reconstruction for lesion detection and localization

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2004-01-01

    Lesion detection is an important task in emission tomography. Localization ROC (LROC) studies are often used to analyze the lesion detection and localization performance. Most researchers rely on Monte Carlo reconstruction samples to obtain LROC curves, which can be very time-consuming for iterative algorithms. In this paper we develop a fast approach to obtain LROC curves that does not require Monte Carlo reconstructions. We use a channelized Hotelling observer model to search for lesions, and the results can be easily extended to other numerical observers. We theoretically analyzed the mean and covariance of the observer output. Assuming the observer outputs are multivariate Gaussian random variables, an LROC curve can be directly generated by integrating the conditional probability density functions. The high-dimensional integrals are calculated using a Monte Carlo method. The proposed approach is very fast because no iterative reconstruction is involved. Computer simulations show that the results of the proposed method match well with those obtained using the tradition LROC analysis

  1. Effect of glatiramer acetate three-times weekly on the evolution of new, active multiple sclerosis lesions into T1-hypointense "black holes": a post hoc magnetic resonance imaging analysis.

    Science.gov (United States)

    Zivadinov, Robert; Dwyer, Michael; Barkay, Hadas; Steinerman, Joshua R; Knappertz, Volker; Khan, Omar

    2015-03-01

    Conversion of active lesions to black holes has been associated with disability progression in subjects with relapsing-remitting multiple sclerosis (RRMS) and represents a complementary approach to evaluating clinical efficacy. The objective of this study was to assess the conversion of new active magnetic resonance imaging (MRI) lesions, identified 6 months after initiating treatment with glatiramer acetate 40 mg/mL three-times weekly (GA40) or placebo, to T1-hypointense black holes in subjects with RRMS. Subjects received GA40 (n = 943) or placebo (n = 461) for 12 months. MRI was obtained at baseline and Months 6 and 12. New lesions were defined as either gadolinium-enhancing T1 or new T2 lesions at Month 6 that were not present at baseline. The adjusted mean numbers of new active lesions at Month 6 converting to black holes at Month 12 were analyzed using a negative binomial model; adjusted proportions of new active lesions at Month 6 converting to black holes at Month 12 were analyzed using a logistic regression model. Of 1,292 subjects with complete MRI data, 433 (50.3 %) GA-treated and 247 (57.2 %) placebo-treated subjects developed new lesions at Month 6. Compared with placebo, GA40 significantly reduced the mean number (0.31 versus 0.45; P = .0258) and proportion (15.8 versus 19.6 %; P = .006) of new lesions converting to black holes. GA significantly reduced conversion of new active lesions to black holes, highlighting the ability of GA40 to prevent tissue damage in RRMS.

  2. Review and management of breast lesions detected with breast tomosynthesis but not visible on mammography and ultrasonography.

    Science.gov (United States)

    Taskin, Fusun; Durum, Yasemin; Soyder, Aykut; Unsal, Alparslan

    2017-12-01

    Background Breast tomosynthesis is more sensitive than mammography and can detect lesions that are not always visible with conventional methods such as digital mammography (MG) and ultrasonography (US). No standardized approach is available for the management of lesions that are detectable with tomosynthesis but are not visible on MG or US. Purpose To review suspicious breast lesions detected with tomosynthesis but not visible on two-dimensional (2D) MG or US and to determine the management options for these lesions. Material and Methods Ethical committee approval was obtained. The radiological records, biopsy or surgery results, and follow-up findings of 107 patients who had a tomosynthesis-positive but MG- or US-negative breast lesion between 2011 and 2016 were retrospectively evaluated. Results Of 107 lesions visible only with tomosynthesis, 74% were architectural distortions and 26% were asymmetrical opacities. All patients underwent magnetic resonance imaging (MRI) for further evaluation. Among the 48 (45%) MRI-negative lesions, none had a suspicious alteration during the follow-up period. Among the MRI-positive lesions, 28% of the 50 architectural distortions and 11% of the nine asymmetrical opacities were malignant. Conclusion Given the inherent high false-positive rate of breast tomosynthesis, breast MRI prior to biopsy may reduce the number of unnecessary biopsies for suspicious breast lesions that are tomosynthesis-positive only.

  3. A typical MR imaging of multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Katagiri, Shinako; Kan, Shinichi; Ikeda, Toshiaki; Nishiyama, Syougo; Nishimaki, Hiroshi; Matsubayashi, Takashi; Hata, Takashi [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine

    1995-06-01

    MR imaging is very useful in detecting the intracranial lesion of multiple sclerosis (MS). We present six patients of MS with atypical MR imaging findings. Six patients aged 27-56 years (mean 36 years), and sexuality of six patients were 2 men and 4 females. Three patient`s clinical course had episodes of optic neuritis. The plaque`s size of the predominant lesion of the patients ranged from 3.0 to 9.0 cm in diameter. The plaques were oval, elliptically and other shaped. At acute stage, MR imaging detected perfocal edema and focal mass effect in three cases of our study. Two out of six cases showed multiple irregularly enhancing lesion with Gadolinium-DTPA. Plaques of all cases did not disappear completely in final MR imaging study. (author).

  4. A typical MR imaging of multiple sclerosis

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Kan, Shinichi; Ikeda, Toshiaki; Nishiyama, Syougo; Nishimaki, Hiroshi; Matsubayashi, Takashi; Hata, Takashi

    1995-01-01

    MR imaging is very useful in detecting the intracranial lesion of multiple sclerosis (MS). We present six patients of MS with atypical MR imaging findings. Six patients aged 27-56 years (mean 36 years), and sexuality of six patients were 2 men and 4 females. Three patient's clinical course had episodes of optic neuritis. The plaque's size of the predominant lesion of the patients ranged from 3.0 to 9.0 cm in diameter. The plaques were oval, elliptically and other shaped. At acute stage, MR imaging detected perfocal edema and focal mass effect in three cases of our study. Two out of six cases showed multiple irregularly enhancing lesion with Gadolinium-DTPA. Plaques of all cases did not disappear completely in final MR imaging study. (author)

  5. Management of breast lesions detectable only on MRI; Abklaerung ausschliesslich MRT-detektierbarer Mammalaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Siegmann-Luz, K.C.; Bahrs, S.D.; Preibsch, H.; Hattermann, V.; Claussen, C.D. [Universitaetsklinikum Tuebingen (Germany). Abt. Diagnostische und Interventionelle Radiologie

    2014-01-15

    Breast MR imaging has become established as the most sensitive imaging method for diagnosing breast cancer. As a result of the increasing examination volume and improved image quality, the number of breast lesions detected only on MRI and requiring further clarification has risen in recent years. According to the S3-guideline 'Diagnosis, Therapy, and Follow-Up of Breast Cancer' as revised in July 2012, institutions performing breast MRI should provide the option of an MRI-guided intervention for clarification. This review describes the indications, methods and results of MRI-guided interventions for the clarification of breast lesions only visible on MRI. Recent guidelines and study results are also addressed and alternative methods and pitfalls are presented. (orig.)

  6. Clinical relevance of studies on the accuracy of visual inspection for detecting caries lesions

    DEFF Research Database (Denmark)

    Gimenez, Thais; Piovesan, Chaiana; Braga, Mariana M

    2015-01-01

    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering...... the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature...... to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study...

  7. Detection and analysis of human papillomavirus 16 and 18 homologous DNA sequences in oral lesions.

    Science.gov (United States)

    Wen, S; Tsuji, T; Li, X; Mizugaki, Y; Hayatsu, Y; Shinozaki, F

    1997-01-01

    The prevalence of human papillomavirus (HPV) 16 and 18 was investigated in oral lesions of the population of northeast China including squamous cell carcinomas (SCCs), candida leukoplakias, lichen planuses and papillomas, by southern blot hybridization with polymerase chain reaction (PCR). Amplified HPV16 and 18 E6 DNA was analyzed by cycle sequence. HPV DNA was detected in 14 of 45 SCCs (31.1%). HPV18 E6 DNA and HPV16 E6. DNA were detected in 24.4% and 20.0% of SCCs. respectively. Dual infection of both HPV 16 and HPV 18 was detected in 6 of 45 SCCs (13.3%), but not in other oral lesions. HPV 18 E6 DNA was also detected in 2 of 3 oral candida leukoplakias, but in none of the 5 papillomas. Our study indicated that HPV 18 infection might be more frequent than HPV 16 infection in oral SCCs in northeast Chinese, dual infection of high risk HPV types was restricted in oral SCCs, and that HPV infection might be involved in the pathogenesis of oral candida leukoplakia.

  8. Nonhemorrhagic brain lesions detected by magnetic resonance imaging in closed head injured patients

    International Nuclear Information System (INIS)

    Kinoshita, Yoshihiro; Hiraide, Atsushi; Yoshioka, Toshiji; Sugimoto, Tadashi; Ichimura, Teruhisa; Saito, Akira; Ohno, Yoshioki.

    1990-01-01

    This study evaluated the diagnostic usefulness of magnetic resonance imaging (MRI) in 83 closed head injured patients in whom CT failed to detect focal intra or extraaxial hematoma and/or apparent brain contusion. The patients were divided into three groups on the basis of unconsciousness duration: Group 1 comprised 50 patients diagnosed as having classical cerebral concussion; group 2 comprised 19 patients who presented to the hospital with 6-hr unconsciousness and was recovered within a week; and group 3 comprised 14 patients whose unconsciousness persisted for a week or more. There was no CT evidence of abnormal findings for group 1; and intraventricular hemorrhage and subarachnoid hemorrhage were visualized on CT in 26% and 16%, respectively, for group 2 and 71% and 14% for group 3. Intraaxial nonhemorrhagic lesions were detected on T2-weighted MRI. According to high signal intensity, diffuse axonal injury and cortical contusion could be distinguished; i.e., in the former the corpus callosum, basal ganglia, or brain stem showed a high signal intensity, and in the latter the frontal, temporal, or parietal lobe adjacent to the skull showed a low signal intensity. T2-weighted MRI revealed cortical contusion in 6% for group 1, 37% for group 2, and 14% for group 3; and diffuse axonal injury in 42% for group 2 and 79% for group 3. For 62 patients with normal CT findings, diffuse axonal injury was detected in 88%. There was a good correlation between intraventricular hemorrhage on CT and diffuse axonal injury on MRI. In conclusion, T2-weighted MRI was significantly superior to CT in detecting nonhemorrhagic lesions, and it was of great help for predicting neurologic recovery in closed head injured patients without apparent focal lesions on CT. (N.K.)

  9. Time-resolved optical mammography between 637 and 985 nm: clinical study on the detection and identification of breast lesions

    International Nuclear Information System (INIS)

    Taroni, Paola; Torricelli, Alessandro; Spinelli, Lorenzo; Pifferi, Antonio; Arpaia, Francesco; Danesini, Gianmaria; Cubeddu, Rinaldo

    2005-01-01

    The first time-resolved optical mammograph operating beyond 900 nm was tested in a retrospective clinical study involving 194 patients with malignant and benign lesions, to investigate the diagnostic potential for the detection and characterization of breast lesions. For the first part of the study (101 patients with 114 lesions), the system was operated at 683, 785, 913 and 975 nm. Subsequently, to improve the spectral content of optical images, the number of wavelengths was increased (up to 7) and the spectral range was extended (637-985 nm). Late gated intensity and scattering images provide sensitivity to tissue composition (oxy- and deoxyhaemoglobin, water and lipids) and physiology (total haemoglobin content and oxygen saturation), as well as to structural changes. Tumours are typically identified because of the strong blood absorption at short wavelengths (637-685 nm), while cysts are characterized by low scattering, leading to a detection rate of approximately 80% for both lesion types, when detection is required in both cranio-caudal and oblique views. The detection rate for other benign lesions, such as fibroadenomas, is presently much lower (<40%). The effectiveness of the technique in localizing and identifying different lesion types was analysed as a function of various parameters (lesion size, compressed breast thickness, age, body mass index, breast parenchymal pattern). The possibility that physiologic changes due to the development of a malignant lesion could affect the entire breast was investigated. The capacity to assess the density of breast based on the average scattering properties was also tested

  10. Harmonizing FDG PET quantification while maintaining optimal lesion detection: prospective multicentre validation in 517 oncology patients

    International Nuclear Information System (INIS)

    Quak, Elske; Le Roux, Pierre-Yves; Robin, Philippe; Bourhis, David; Salaun, Pierre-Yves; Hofman, Michael S.; Callahan, Jason; Binns, David; Hicks, Rodney J.; Desmonts, Cedric; Aide, Nicolas

    2015-01-01

    Point-spread function (PSF) or PSF + time-of-flight (TOF) reconstruction may improve lesion detection in oncologic PET, but can alter quantitation resulting in variable standardized uptake values (SUVs) between different PET systems. This study aims to validate a proprietary software tool (EQ.PET) to harmonize SUVs across different PET systems independent of the reconstruction algorithm used. NEMA NU2 phantom data were used to calculate the appropriate filter for each PSF or PSF+TOF reconstruction from three different PET systems, in order to obtain EANM compliant recovery coefficients. PET data from 517 oncology patients were reconstructed with a PSF or PSF+TOF reconstruction for optimal tumour detection and an ordered subset expectation maximization (OSEM3D) reconstruction known to fulfil EANM guidelines. Post-reconstruction, the proprietary filter was applied to the PSF or PSF+TOF data (PSF EQ or PSF+TOF EQ ). SUVs for PSF or PSF+TOF and PSF EQ or PSF+TOF EQ were compared to SUVs for the OSEM3D reconstruction. The impact of potential confounders on the EQ.PET methodology including lesion and patient characteristics was studied, as was the adherence to imaging guidelines. For the 1380 tumour lesions studied, Bland-Altman analysis showed a mean ratio between PSF or PSF+TOF and OSEM3D of 1.46 (95 %CI: 0.86-2.06) and 1.23 (95 %CI: 0.95-1.51) for SUV max and SUV peak , respectively. Application of the proprietary filter improved these ratios to 1.02 (95 %CI: 0.88-1.16) and 1.04 (95 %CI: 0.92-1.17) for SUV max and SUV peak , respectively. The influence of the different confounding factors studied (lesion size, location, radial offset and patient's BMI) was less than 5 %. Adherence to the European Association of Nuclear Medicine (EANM) guidelines for tumour imaging was good. These data indicate that it is not necessary to sacrifice the superior lesion detection and image quality achieved by newer reconstruction techniques in the quest for harmonizing quantitative

  11. Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions

    International Nuclear Information System (INIS)

    Obenauer, S.; Luftner-Nagel, S.; Heyden, D. von; Baum, F.; Grabbe, E.; Munzel, U.

    2002-01-01

    The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-film system (Senographe DMR) and the other with a digital detector (Senographe 2000D, both GEMS). Screen-film and digital mammograms were performed on 55 patients with cytologically or histologically proven tumors on the same day. Together with these, 75 digital mammograms of patients without tumor and the corresponding previous screen-film mammograms not older than 1.5 years were reviewed by three observers in a random order. Contrast, exposure, and the presence of artifacts were evaluated. Different details, such as the skin, the retromamillary region, and the parenchymal structures, were judged according to a three-point ranking scale. Finally, the detectability of microcalcifications and lesions were compared and correlated to histology. Image contrast was judged to be good in 76%, satisfactory in 20%, and unsatisfactory in 4% of screen-film mammograms. Digital mammograms were judged to be good in 99% and unsatisfactory in 1% of cases. Improper exposure of screen-film system occurred in 18% (10% overexposed and 8% underexposed). Digital mammograms were improperly exposed in 4% of all cases but were of acceptable quality after post-processing. Artifacts, most of them of no significance, were found in 78% of screen-film and in none of the digital mammograms. Different anatomical regions, such as the skin, the retromamillary region, and dense parenchymal areas, were better visualized in digital than in screen-film mammography. All malignant tumors were seen by the three radiologists; however, digital mammograms allowed a better characterization of these lesions to the Breast Imaging Reporting and Data System (BI-RADSZZZ;) categories (FFDM better than

  12. Impact of compressed breast thickness and dose on lesion detectability in digital mammography: FROC study with simulated lesions in real mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Salvagnini, Elena, E-mail: elena.salvagnini@gmail.com [Department of Imaging and Pathology, Radiology, KUL, Herestraat 49, Leuven B-3000 (Belgium); SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Bosmans, Hilde; Marshall, Nicholas W. [Department of Imaging and Pathology, Radiology, KUL, Herestraat 49, Leuven B-3000 (Belgium); Department of Radiology, Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium); Van Ongeval, Chantal; Van Steen, Andreas; Cockmartin, Lesley [Department of Radiology, Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium); Michielsen, Koen [Department of Imaging and Pathology, Nuclear Medicine and Molecular Imaging, KUL, Herestraat 49, Leuven B-3000 (Belgium); Struelens, Lara [SCK-CEN, Boeretang 200, Mol 2400 (Belgium)

    2016-09-15

    Purpose: The aim of this work was twofold: (1) to examine whether, with standard automatic exposure control (AEC) settings that maintain pixel values in the detector constant, lesion detectability in clinical images decreases as a function of breast thickness and (2) to verify whether a new AEC setup can increase lesion detectability at larger breast thicknesses. Methods: Screening patient images, acquired on two identical digital mammography systems, were collected over a period of 2 yr. Mammograms were acquired under standard AEC conditions (part 1) and subsequently with a new AEC setup (part 2), programmed to use the standard AEC settings for compressed breast thicknesses ≤49 mm, while a relative dose increase was applied above this thickness. The images were divided into four thickness groups: T1 ≤ 29 mm, T2 = 30–49 mm, T3 = 50–69 mm, and T4 ≥ 70 mm, with each thickness group containing 130 randomly selected craniocaudal lesion-free images. Two measures of density were obtained for every image: a BI-RADS score and a map of volumetric breast density created with a software application (VolparaDensity, Matakina, NZ). This information was used to select subsets of four images, containing one image from each thickness group, matched to a (global) BI-RADS score and containing a region with the same (local) VOLPARA volumetric density value. One selected lesion (a microcalcification cluster or a mass) was simulated into each of the four images. This process was repeated so that, for a given thickness group, half the images contained a single lesion and half were lesion-free. The lesion templates created and inserted in groups T3 and T4 for the first part of the study were then inserted into the images of thickness groups T3 and T4 acquired with higher dose settings. Finally, all images were visualized using the ViewDEX software and scored by four radiologists performing a free search study. A statistical jackknife-alternative free-response receiver operating

  13. Automatic Detection of Lung and Liver Lesions in 3-D Positron Emission Tomography Images: A Pilot Study

    Science.gov (United States)

    Lartizien, Carole; Marache-Francisco, Simon; Prost, Rémy

    2012-02-01

    Positron emission tomography (PET) using fluorine-18 deoxyglucose (18F-FDG) has become an increasingly recommended tool in clinical whole-body oncology imaging for the detection, diagnosis, and follow-up of many cancers. One way to improve the diagnostic utility of PET oncology imaging is to assist physicians facing difficult cases of residual or low-contrast lesions. This study aimed at evaluating different schemes of computer-aided detection (CADe) systems for the guided detection and localization of small and low-contrast lesions in PET. These systems are based on two supervised classifiers, linear discriminant analysis (LDA) and the nonlinear support vector machine (SVM). The image feature sets that serve as input data consisted of the coefficients of an undecimated wavelet transform. An optimization study was conducted to select the best combination of parameters for both the SVM and the LDA. Different false-positive reduction (FPR) methods were evaluated to reduce the number of false-positive detections per image (FPI). This includes the removal of small detected clusters and the combination of the LDA and SVM detection maps. The different CAD schemes were trained and evaluated based on a simulated whole-body PET image database containing 250 abnormal cases with 1230 lesions and 250 normal cases with no lesion. The detection performance was measured on a separate series of 25 testing images with 131 lesions. The combination of the LDA and SVM score maps was shown to produce very encouraging detection performance for both the lung lesions, with 91% sensitivity and 18 FPIs, and the liver lesions, with 94% sensitivity and 10 FPIs. Comparison with human performance indicated that the different CAD schemes significantly outperformed human detection sensitivities, especially regarding the low-contrast lesions.

  14. Contralateral lesions detected by preoperative MRI in patients with recently diagnosed breast cancer: Application of MR CAD in differentiation of benign and malignant lesions

    International Nuclear Information System (INIS)

    Cho, Nariya; Kim, Sun Mi; Park, Jeong Seon; Jang, Mijung; Kim, Soo-Yeon; Chang, Jung Min; Moon, Woo Kyung

    2012-01-01

    Objectives: To retrospectively investigate the added value of kinetic features measured by computer-aided diagnosis (CAD) for differentiating benign and malignant contralateral breast lesions detected by preoperative MRI in breast cancer patients. Methods: This study was approved by our institutional review board, and the requirement for informed consent was waived. Fifty-two breast MR images and their CAD kinetic features were obtained for 52 consecutive breast cancer patients with contralateral breast lesions detected by preoperative MRI and confirmed by excision (23 cancers and 29 benign lesions). Three experienced radiologists independently reviewed the MR images without CAD information and assessed probabilities of malignancy. Four weeks later, these probabilities were reanalyzed using stored CAD data. Diagnostic performances and detection rates of delayed washout components were compared between interpretations without and with CAD for each reader. Results: Use of MR CAD increased detection of washout component by 2.4- to 3.7-fold than visual assessment for enhancing contralateral lesions, which increased sensitivity (91% vs. 87% in reader 1; 96% vs. 74% in reader 2; 91% vs. 70% in reader 3) and decreased specificity, but statistical significance was only found for decreased specificity in one reader (52% vs. 28%, P = 0.039), and overall performance (areas under ROC curves 0.672 vs. 0.616 in reader 1; 0.624 vs. 0.603 in reader 2; 0.706 vs. 0.590 in reader 3) remained unimproved. Conclusion: Addition of MR CAD increased sensitivity and decreased specificity than radiologist's assessment alone for differentiating benign and malignant contralateral lesions in breast cancer patients and overall performance remained unimproved.

  15. Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison

    International Nuclear Information System (INIS)

    Schmaranzer, Florian; Klauser, Andrea; Henninger, Benjamin; Kogler, Michael; Schmaranzer, Ehrenfried; Forstner, Thomas; Reichkendler, Markus

    2015-01-01

    To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. (orig.)

  16. Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison

    Energy Technology Data Exchange (ETDEWEB)

    Schmaranzer, Florian; Klauser, Andrea; Henninger, Benjamin [Medical University Innsbruck, Department of Radiology, Innsbruck (Austria); Kogler, Michael; Schmaranzer, Ehrenfried [District Hospital St. Johann in Tyrol, Department of Radiology, St. Johann in Tyrol (Austria); Forstner, Thomas [Johannes Keppler University, Department for Applied Systems Research and Statistics, Linz (Austria); Reichkendler, Markus [District Hospital St. Johann in Tyrol, Department of Orthopedic Surgery, St. Johann in Tyrol (Austria)

    2015-06-01

    To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. (orig.)

  17. Real-time PCR detection of Brucella spp. DNA in lesions and viscera of bovine carcasses.

    Science.gov (United States)

    Sola, Marília Cristina; da Veiga Jardim, Eurione A G; de Freitas, Marcius Ribeiro; de Mesquita, Albenones José

    2014-09-01

    This study reports a real-time PCR assay for the detection of Brucella spp. associated with the FTA® Elute method in lesions observed during sanitary inspections in beef slaughter. Of the total 276 samples, 78 (28.3%) tested positive and 198 (71.7%) negative for Brucella spp. The real-time PCR technique associated with the FTA® Elute method proved to be an important tool for the diagnosis, judgment about and disposal of carcasses and viscera of slaughtered animals. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Claudin-4-targeted optical imaging detects pancreatic cancer and its precursor lesions.

    Science.gov (United States)

    Neesse, Albrecht; Hahnenkamp, Anke; Griesmann, Heidi; Buchholz, Malte; Hahn, Stefan A; Maghnouj, Abdelouahid; Fendrich, Volker; Ring, Janine; Sipos, Bence; Tuveson, David A; Bremer, Christoph; Gress, Thomas M; Michl, Patrick

    2013-07-01

    Novel imaging methods based on specific molecular targets to detect both established neoplasms and their precursor lesions are highly desirable in cancer medicine. Previously, we identified claudin-4, an integral constituent of tight junctions, as highly expressed in various gastrointestinal tumours including pancreatic cancer. Here, we investigate the potential of targeting claudin-4 with a naturally occurring ligand to visualise pancreatic cancer and its precursor lesions in vitro and in vivo by near-infrared imaging approaches. A non-toxic C-terminal fragment of the claudin-4 ligand Clostridium perfringens enterotoxin (C-CPE) was labelled with a cyanine dye (Cy5.5). Binding of the optical tracer was analysed on claudin-4 positive and negative cells in vitro, and tumour xenografts in vivo. In addition, two genetically engineered mouse models for pancreatic intraepithelial neoplasia (PanIN) and pancreatic cancer were used for in vivo validation. Optical imaging studies were conducted using 2D planar fluorescence reflectance imaging (FRI) technology and 3D fluorescence-mediated tomography (FMT). In vitro, the peptide-dye conjugate showed high binding affinity to claudin-4 positive CAPAN1 cells, while claudin-4 negative HT1080 cells revealed little or no fluorescence. In vivo, claudin-4 positive tumour xenografts, endogenous pancreatic tumours, hepatic metastases, as well as preinvasive PanIN lesions, were visualised by FRI and FMT up to 48 h after injection showing a significantly higher average of fluorochrome concentration as compared with claudin-4 negative xenografts and normal pancreatic tissue. C-CPE-Cy5.5 combined with novel optical imaging methods enables non-invasive visualisation of claudin-4 positive murine pancreatic tumours and their precursor lesions, representing a promising modality for early diagnostic imaging.

  19. Measuring telomere length for the early detection of precursor lesions of esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Lin, Shih-Wen; Wang, Guo-Qing; Wei, Wen-Qiang; Lu, Ning; Taylor, Philip R; Qiao, You-Lin; Dawsey, Sanford M; Abnet, Christian C; Freedman, Neal D; Murphy, Gwen; Risques, Rosana; Prunkard, Donna; Rabinovitch, Peter; Pan, Qin-Jing; Roth, Mark J

    2013-01-01

    Esophageal cancer is the sixth leading cause of cancer death worldwide; current early detection screening tests are inadequate. Esophageal balloon cytology successfully retrieves exfoliated and scraped superficial esophageal epithelial cells, but cytologic reading of these cells has poor sensitivity and specificity for detecting esophageal squamous dysplasia (ESD), the precursor lesion of esophageal squamous cell carcinoma (ESCC). Measuring telomere length, a marker for chromosomal instability, may improve the utility of balloon cytology for detecting ESD and early ESCC. We examined balloon cytology specimens from 89 asymptomatic cases of ESD (37 low-grade and 52 high-grade) and 92 age- and sex-matched normal controls from an esophageal cancer early detection screening study. All subjects also underwent endoscopy and biopsy, and ESD was diagnosed histopathologically. DNA was extracted from the balloon cytology cells, and telomere length was measured by quantitative PCR. A receiver operating characteristic (ROC) curve was plotted for telomere length as a diagnostic marker for high-grade dysplasia. Telomere lengths were comparable among the low- and high-grade dysplasia cases and controls, with means of 0.96, 0.96, and 0.92, respectively. The area under the ROC curve was 0.55 for telomere length as a diagnostic marker for high-grade dysplasia. Further adjustment for subject characteristics, including sex, age, smoking, drinking, hypertension, and body mass index did not improve the use of telomere length as a marker for ESD. Telomere length of esophageal balloon cytology cells was not associated with ESCC precursor lesions. Therefore, telomere length shows little promise as an early detection marker for ESCC in esophageal balloon samples

  20. What affects detectability of lesion–deficit relationships in lesion studies?

    Directory of Open Access Journals (Sweden)

    Kayo Inoue

    2014-01-01

    Our simulations offer a quantitative basis for interpreting lesion studies in cognitive neuroscience. We suggest ways in which lesion simulation and analysis frameworks could be productively extended.

  1. Positron emission mammography (PEM): Effect of activity concentration, object size, and object contrast on phantom lesion detection

    International Nuclear Information System (INIS)

    MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna; Haseley, David; Kelly, Mary M.; Liu, Franklin; Parikh, Jay R.; Beatty, J. David; Rogers, James V.

    2012-01-01

    Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44–4.1 kBq/mL, corresponding to 46–400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to score the presence of spheres. Results: Sensitivity was 100% for lesions ≥12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained ≥90% for injected activities as low as 100 MBq, for lesions ≥8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.

  2. MR brain scanning in patients with vasculitis: Differentiation from multiple sclerosis

    International Nuclear Information System (INIS)

    Miller, D.H.; Ormerod, I.E.C.; Du Boulay, E.P.G.H.; Rudge, P.; McDonald, W.I.; Gibson, A.

    1987-01-01

    We performed MR (magnetic resonance) brain imaging on 24 patients with a systemic vasculitis. MRI proved to be a sensitive method for detecting brain lesions (clinically silent or manifest) in these patients. The most frequent abnormalities were periventricular lesions seen in 12 cases. Such changes are not specific for vascular disease, and are often seen in multiple sclerosis. However, additional changes were commonly seen which suggested the correct diagnosis. (orig.)

  3. An object-based approach for detecting small brain lesions: application to Virchow-Robin spaces.

    Science.gov (United States)

    Descombes, Xavier; Kruggel, Frithjof; Wollny, Gert; Gertz, Hermann Josef

    2004-02-01

    This paper is concerned with the detection of multiple small brain lesions from magnetic resonance imaging (MRI) data. A model based on the marked point process framework is designed to detect Virchow-Robin spaces (VRSs). These tubular shaped spaces are due to retraction of the brain parenchyma from its supplying arteries. VRS are described by simple geometrical objects that are introduced as small tubular structures. Their radiometric properties are embedded in a data term. A prior model includes interactions describing the clustering property of VRS. A Reversible Jump Markov Chain Monte Carlo algorithm (RJMCMC) optimizes the proposed model, obtained by multiplying the prior and the data model. Example results are shown on T1-weighted MRI datasets of elderly subjects.

  4. A Robust and Fast System for CTC Computer-Aided Detection of Colorectal Lesions

    Directory of Open Access Journals (Sweden)

    Gareth Beddoe

    2010-01-01

    Full Text Available We present a complete, end-to-end computer-aided detection (CAD system for identifying lesions in the colon, imaged with computed tomography (CT. This system includes facilities for colon segmentation, candidate generation, feature analysis, and classification. The algorithms have been designed to offer robust performance to variation in image data and patient preparation. By utilizing efficient 2D and 3D processing, software optimizations, multi-threading, feature selection, and an optimized cascade classifier, the CAD system quickly determines a set of detection marks. The colon CAD system has been validated on the largest set of data to date, and demonstrates excellent performance, in terms of its high sensitivity, low false positive rate, and computational efficiency.

  5. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    Science.gov (United States)

    Cheng, Haynes P. H.; Svenmarker, Pontus; Xie, Haiyan; Tidemand-Lichtenberg, Peter; Jensen, Ole B.; Bendsoe, Niels; Svanberg, Katarina; Petersen, Paul Michael; Pedersen, Christian; Andersson-Engels, Stefan; Andersen, Peter E.

    2010-04-01

    We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-tonoise ratio to be achieved in the resulting autofluorescence signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image capture is sampled at 5 kHz and the resulting autofluorescence is captured with the liquid crystal filter cycling through seven wavelengths between 420 nm and 580 nm. The clinical study targets pigmented skin lesions and evaluates the prospects of using autofluorescence as a possible means in differentiating malignant and benign skin tumors. Up to now, sixteen patients have participated in the clinical study. The autofluorescence images, averaged over the exposure time of one second, will be presented along with histopathological results. Initial survey of the images show good contrast and diagnostic results show promising agreement based on the histopathological results.

  6. Management for BI-RADS category 3 lesions detected in preoperative breast MR imaging of breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Gweon, Hye Mi [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Gangnam Severance Hospital, Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cho, Nariya; Kim, Soo-Yeon [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Koo, Hye Ryoung [Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seo, Mirinae [Kyung Hee University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Chu, Ajung [Seoul National University College of Medicine, Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Son, Eun Ju [Gangnam Severance Hospital, Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2017-08-15

    To retrospectively evaluate characteristics of and determine appropriate follow-up recommendations for BI-RADS category 3 lesions detected in preoperative MRI of breast cancer patients. BI-RADS category 3 assessments were identified from the breast MRI database for 5,110 consecutive breast cancer patients who had undergone preoperative MRI and surgery. Patient and lesion characteristics, malignancy rate, and interval between lesion detection and cancer diagnosis were analysed. Histopathological results or imaging at or after 2-year follow-up were used as reference standards. Of the 626 lesions, morphological features included a single focus in 26.5% (n = 166), multiple foci in 47.1% (n = 295), mass in 21.7% (n = 136) and non-mass enhancement in 4.6% (n = 29). Cancer was found in 0.8% (5/626) at a median interval of 50 months (range, 29-66 months). Malignancy rate according to morphological feature was: 1.8% (3/166) in a single focus, 0.7% (1/136) in mass and 3.4% (1/29) in non-mass enhancement. All detected cancers were stage 0 or IA. Annual follow-up might be adequate for BI-RADS category 3 lesions detected at preoperative MRI because of the 0.8% (5/626) malignancy rate, long interval between lesion detection and cancer diagnosis, and early stage of diagnosed cancers. (orig.)

  7. Dissociation of Detection and Discrimination of Pure Tones following Bilateral Lesions of Auditory Cortex

    Science.gov (United States)

    Dykstra, Andrew R.; Koh, Christine K.; Braida, Louis D.; Tramo, Mark Jude

    2012-01-01

    It is well known that damage to the peripheral auditory system causes deficits in tone detection as well as pitch and loudness perception across a wide range of frequencies. However, the extent to which to which the auditory cortex plays a critical role in these basic aspects of spectral processing, especially with regard to speech, music, and environmental sound perception, remains unclear. Recent experiments indicate that primary auditory cortex is necessary for the normally-high perceptual acuity exhibited by humans in pure-tone frequency discrimination. The present study assessed whether the auditory cortex plays a similar role in the intensity domain and contrasted its contribution to sensory versus discriminative aspects of intensity processing. We measured intensity thresholds for pure-tone detection and pure-tone loudness discrimination in a population of healthy adults and a middle-aged man with complete or near-complete lesions of the auditory cortex bilaterally. Detection thresholds in his left and right ears were 16 and 7 dB HL, respectively, within clinically-defined normal limits. In contrast, the intensity threshold for monaural loudness discrimination at 1 kHz was 6.5±2.1 dB in the left ear and 6.5±1.9 dB in the right ear at 40 dB sensation level, well above the means of the control population (left ear: 1.6±0.22 dB; right ear: 1.7±0.19 dB). The results indicate that auditory cortex lowers just-noticeable differences for loudness discrimination by approximately 5 dB but is not necessary for tone detection in quiet. Previous human and Old-world monkey experiments employing lesion-effect, neurophysiology, and neuroimaging methods to investigate the role of auditory cortex in intensity processing are reviewed. PMID:22957087

  8. Dissociation of detection and discrimination of pure tones following bilateral lesions of auditory cortex.

    Science.gov (United States)

    Dykstra, Andrew R; Koh, Christine K; Braida, Louis D; Tramo, Mark Jude

    2012-01-01

    It is well known that damage to the peripheral auditory system causes deficits in tone detection as well as pitch and loudness perception across a wide range of frequencies. However, the extent to which to which the auditory cortex plays a critical role in these basic aspects of spectral processing, especially with regard to speech, music, and environmental sound perception, remains unclear. Recent experiments indicate that primary auditory cortex is necessary for the normally-high perceptual acuity exhibited by humans in pure-tone frequency discrimination. The present study assessed whether the auditory cortex plays a similar role in the intensity domain and contrasted its contribution to sensory versus discriminative aspects of intensity processing. We measured intensity thresholds for pure-tone detection and pure-tone loudness discrimination in a population of healthy adults and a middle-aged man with complete or near-complete lesions of the auditory cortex bilaterally. Detection thresholds in his left and right ears were 16 and 7 dB HL, respectively, within clinically-defined normal limits. In contrast, the intensity threshold for monaural loudness discrimination at 1 kHz was 6.5 ± 2.1 dB in the left ear and 6.5 ± 1.9 dB in the right ear at 40 dB sensation level, well above the means of the control population (left ear: 1.6 ± 0.22 dB; right ear: 1.7 ± 0.19 dB). The results indicate that auditory cortex lowers just-noticeable differences for loudness discrimination by approximately 5 dB but is not necessary for tone detection in quiet. Previous human and Old-world monkey experiments employing lesion-effect, neurophysiology, and neuroimaging methods to investigate the role of auditory cortex in intensity processing are reviewed.

  9. Dissociation of detection and discrimination of pure tones following bilateral lesions of auditory cortex.

    Directory of Open Access Journals (Sweden)

    Andrew R Dykstra

    Full Text Available It is well known that damage to the peripheral auditory system causes deficits in tone detection as well as pitch and loudness perception across a wide range of frequencies. However, the extent to which to which the auditory cortex plays a critical role in these basic aspects of spectral processing, especially with regard to speech, music, and environmental sound perception, remains unclear. Recent experiments indicate that primary auditory cortex is necessary for the normally-high perceptual acuity exhibited by humans in pure-tone frequency discrimination. The present study assessed whether the auditory cortex plays a similar role in the intensity domain and contrasted its contribution to sensory versus discriminative aspects of intensity processing. We measured intensity thresholds for pure-tone detection and pure-tone loudness discrimination in a population of healthy adults and a middle-aged man with complete or near-complete lesions of the auditory cortex bilaterally. Detection thresholds in his left and right ears were 16 and 7 dB HL, respectively, within clinically-defined normal limits. In contrast, the intensity threshold for monaural loudness discrimination at 1 kHz was 6.5 ± 2.1 dB in the left ear and 6.5 ± 1.9 dB in the right ear at 40 dB sensation level, well above the means of the control population (left ear: 1.6 ± 0.22 dB; right ear: 1.7 ± 0.19 dB. The results indicate that auditory cortex lowers just-noticeable differences for loudness discrimination by approximately 5 dB but is not necessary for tone detection in quiet. Previous human and Old-world monkey experiments employing lesion-effect, neurophysiology, and neuroimaging methods to investigate the role of auditory cortex in intensity processing are reviewed.

  10. Experimental phantom lesion detectability study using a digital breast tomosynthesis prototype system

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Lell, M.; Boehner, C.; Bautz, W.A.; Mertelmeier, T.

    2006-01-01

    Purpose: To compare the sensitivity of conventional two-dimensional (2D) projection imaging with tomosynthesis with respect to the detectability of mammographic phantom lesions. Materials and Methods: Using a breast tomosynthesis prototype based on a commercial FFDM system (Siemens MAMMOMAT Novation DR ), but modified for a wide angle tube motion and equipped with a fast read-out amorphous selenium detector, we acquired standard 2D images and tomosynthesis series of projection views. We used the Wisconsin mammographic random phantom, model RMI 152A. The anode filter combinations Mo/Mo and W/Rh at two different doses were used as typical radiographic techniques. Slice images through the phantom parallel to the detector were reconstructed with a distance of 1 mm employing a filtered back-projection algorithm. The image data sets were read by five radiologists and evaluated with respect to the detectability of the phantom details. Results: For all studied radiographic techniques, the detection rate in the tomosynthesis mode was 100%, i.e. 75 true positive findings out of 75 possible hits. In contrast, the conventional projection mode yielded a detection rate between 80 and 93% (corresponding to 60 and 70 detected details) depending on the dose and X-ray spectrum. Conclusion: Tomosynthesis has the potential to increase the sensitivity of digital mammography. Overlapping structures from out-of-plane tissue can be removed in the tomosynthesis reconstruction process, thereby enhancing the diagnostic accuracy. (orig.)

  11. A new automated quantification algorithm for the detection and evaluation of focal liver lesions with contrast-enhanced ultrasound.

    Science.gov (United States)

    Gatos, Ilias; Tsantis, Stavros; Spiliopoulos, Stavros; Skouroliakou, Aikaterini; Theotokas, Ioannis; Zoumpoulis, Pavlos; Hazle, John D; Kagadis, George C

    2015-07-01

    Detect and classify focal liver lesions (FLLs) from contrast-enhanced ultrasound (CEUS) imaging by means of an automated quantification algorithm. The proposed algorithm employs a sophisticated segmentation method to detect and contour focal lesions from 52 CEUS video sequences (30 benign and 22 malignant). Lesion detection involves wavelet transform zero crossings utilization as an initialization step to the Markov random field model toward the lesion contour extraction. After FLL detection across frames, time intensity curve (TIC) is computed which provides the contrast agents' behavior at all vascular phases with respect to adjacent parenchyma for each patient. From each TIC, eight features were automatically calculated and employed into the support vector machines (SVMs) classification algorithm in the design of the image analysis model. With regard to FLLs detection accuracy, all lesions detected had an average overlap value of 0.89 ± 0.16 with manual segmentations for all CEUS frame-subsets included in the study. Highest classification accuracy from the SVM model was 90.3%, misdiagnosing three benign and two malignant FLLs with sensitivity and specificity values of 93.1% and 86.9%, respectively. The proposed quantification system that employs FLLs detection and classification algorithms may be of value to physicians as a second opinion tool for avoiding unnecessary invasive procedures.

  12. Proton density differences in signal characteristics of multiple sclerosis plaques versus white matter lesions of small vessel disease and vasculitis on high-field strength MR images

    International Nuclear Information System (INIS)

    Peyster, R.G.; Siegal, T.L.

    1990-01-01

    This paper determines if variations in signal intensity characteristics on multi-spin-echo images obtained with a high-field-strength magnet can be useful in differentiating demyelinating plaques of multiple sclerosis from other pathologic white matter processes due to small vessel disease and vasculities. Using the first of two multi-spin-echo images obtained with a General Electric 1.5-T magnet, the investigators compared signal intensity characteristics in 30 patients with a firm clinical diagnosis of multiple sclerosis versus a control group of 30 patients with a known clinical history of small-vessel disease and vasculitis are isodense to gray matter on proton-density images

  13. MRI lesion and epileptogenic focus in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Matsuda, Kazumi; Yagi, Kazuichi; Mihara, Tadahiro; Tottori, Takayasu; Watanabe, Yutaka; Seino, Masakazu

    1989-01-01

    The spatial relationship between a circumscribed lesion in the temporal lobe detected by MRI and an epileptogenic focus identified by ictal depth EEG along with a correlation of the MRI lesion with neuropathological findings were investigated in patients with medically intractable temporal lobe epilepsy but without any focal lesion on CT. Four parameters (an areal ratio of the temporal lobe against the hemisphere, area and calculated T1, T2 values of the hippocampus) were used to determine the abnormal MRI side. An agreement was reached in 67-72% of 18 patients between the abnormal values of the hippocampal area and of calculated T1, T2 and the side of the epileptogenic focus. In 14 of 17 patients, typical hippocampal sclerosis was demonstrated in resected tissue in accordance with the MRI lesions (atrophy and/or prolonged T2 of hippocampus). These results imply: 1)MRI abnormality thus defined may, if not all, indicate the side of the epileptogenic focus, and 2)also the presence of hippocampal sclerosis. It was emphasized that the MRI lesion would be a usable instrument to explore the causal relationship of hippocampal sclerosis to a generation of epileptogenic lesions as well as for presurgical evalution. (author)

  14. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  15. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    International Nuclear Information System (INIS)

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guang Qing; Cui, Xiao Jing; Liang, Xian

    2016-01-01

    The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501) and 94.2% (389/413), respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177) vs. liver without fat infiltration (389/413) (P=0.277); mild fatty liver (162/177) vs. moderate fatty liver (190/212) (P=0.604); mild fatty liver (162/177) vs. severe fatty liver (83/112) (P<0.001); moderate fatty liver (190/212) vs. liver without fat infiltration (389/413) (P=0.051); moderate fatty liver (190/212) vs. severe fatty liver (83/112) (P<0.001); severe fatty liver (83/112) vs. liver without fat infiltration (389/413) (P<0.001); and fatty liver (435/501) vs. liver without fat infiltration (389/413) (P<0.001). Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis

  16. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guang Qing; Cui, Xiao Jing; Liang, Xian [Affiliated Hospital of Hainan Medical College, Haikou (China)

    2016-01-15

    The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501) and 94.2% (389/413), respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177) vs. liver without fat infiltration (389/413) (P=0.277); mild fatty liver (162/177) vs. moderate fatty liver (190/212) (P=0.604); mild fatty liver (162/177) vs. severe fatty liver (83/112) (P<0.001); moderate fatty liver (190/212) vs. liver without fat infiltration (389/413) (P=0.051); moderate fatty liver (190/212) vs. severe fatty liver (83/112) (P<0.001); severe fatty liver (83/112) vs. liver without fat infiltration (389/413) (P<0.001); and fatty liver (435/501) vs. liver without fat infiltration (389/413) (P<0.001). Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis.

  17. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  18. Theoretical Analysis of Penalized Maximum-Likelihood Patlak Parametric Image Reconstruction in Dynamic PET for Lesion Detection.

    Science.gov (United States)

    Yang, Li; Wang, Guobao; Qi, Jinyi

    2016-04-01

    Detecting cancerous lesions is a major clinical application of emission tomography. In a previous work, we studied penalized maximum-likelihood (PML) image reconstruction for lesion detection in static PET. Here we extend our theoretical analysis of static PET reconstruction to dynamic PET. We study both the conventional indirect reconstruction and direct reconstruction for Patlak parametric image estimation. In indirect reconstruction, Patlak parametric images are generated by first reconstructing a sequence of dynamic PET images, and then performing Patlak analysis on the time activity curves (TACs) pixel-by-pixel. In direct reconstruction, Patlak parametric images are estimated directly from raw sinogram data by incorporating the Patlak model into the image reconstruction procedure. PML reconstruction is used in both the indirect and direct reconstruction methods. We use a channelized Hotelling observer (CHO) to assess lesion detectability in Patlak parametric images. Simplified expressions for evaluating the lesion detectability have been derived and applied to the selection of the regularization parameter value to maximize detection performance. The proposed method is validated using computer-based Monte Carlo simulations. Good agreements between the theoretical predictions and the Monte Carlo results are observed. Both theoretical predictions and Monte Carlo simulation results show the benefit of the indirect and direct methods under optimized regularization parameters in dynamic PET reconstruction for lesion detection, when compared with the conventional static PET reconstruction.

  19. Comparing Melanoma Invasiveness in Dermatologist- versus Patient-Detected Lesions: A Retrospective Chart Review

    Directory of Open Access Journals (Sweden)

    Cindy L. Lamerson

    2012-01-01

    Full Text Available This study examined whether patient-identified melanomas were more advanced than dermatologist-identified tumors at routine clinic visits, and whether a personal or family history of skin cancer was associated with patterns of detection. A retrospective chart review was performed on melanoma patients (N=201 in a private dermatology clinic. Variables included age, gender, pattern of detection (i.e., patient or a board certified dermatologist, personal or family history of skin cancer, skin type, and previous sun exposure, as well as tumor location and severity. Dermatologist-diagnosed melanomas were less invasive (P<0.0005, and more likely present on the chest, back, and legs (P<0.01. Conversely, patient-identified lesions were more likely to occur on the face, neck and scalp, be associated with younger patients, and a family history of melanoma, but not other types of skin cancer (P<0.01. In a post-hoc analysis examining these factors as predictors of tumor invasiveness, only diagnostic source was significant. Specifically, dermatologist-identified tumors were significantly less invasive than patient-identified tumors. Although age, family history, and tumor location played roles in the early detection of melanomas, the most important factor was diagnostic source. Thus, board-certified dermatologists play a key role in the early detection of malignant melanoma.

  20. Proliferative changes in nonpalpable breast lesions detected by mammography; Alteraciones profiferativas de la mama en lesiones no palpables detectadas por mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Vega, A.; Delgado, A.; Ortega, E.; Garijo, F. [Hospital Universitario Marques de Valdecilla. Santander (Spain); Mosquera, J.; Sogo, C.; Alvarez, A. [Complejo Hospitalario Juan Canalejo. La Coruna (Spain)

    2000-07-01

    To analyze retrospectively the radiological findings in nonpalpable breast lesions detected by mammography that lead to the performance of surgical biopsy, resulting in a histological diagnosis of proliferative breast disease with and without atypia. From two Spanish hospitals, 421 women with 429 biopsies indicative of the presence of proliferative breast disease with and without atypia were selected out of a total of 1252 surgical biopsies in nonpalpable lesions that proved to be benign. Age, personal and familial history of breast cancer, reason for requesting the mammography and radiological findings that had indicated the need for surgical biopsy were recorded for each patient. The diagnosis was proliferative breast disease (epithelial hyperplasia) in 347 women with 354 biopsies and atypical hyperplasia in the remaining 74 women with 75 biopsies, representing 28% and 6%, respectively, of the 1252 biopsies of lesions found to be benign. In 221 of the 354 cases of epithelial hyperplasia (62%) and 45 of the 75 cases of atypical hyperplasia (60%), the presence of calcifications was the most common radiological findings leading to biopsy (p<0.05). Parenchymal distortion, with or without calcifications, was the second most common radiological sign. The histological study revealed a close relationship between these proliferative events and radial scars. Calcifications are the radiological finding that most frequently indicate the need for surgical biopsy in nonpalpable lesions that results in a diagnosis of proliferative breast disease with and without atypia. (Author) 12 refs.

  1. Evaluation of a radiographic method to detect tibial dyschondroplasia lesions in broilers

    Directory of Open Access Journals (Sweden)

    K Pelicia

    2012-06-01

    Full Text Available This study aimed at developing radiographic techniques for the early detection of dyschondroplastic lesions in the tibia of broilers. The experiment was carried out at the facilities of UNIFOR/MG and Formiga and UNIFENAS/ Alfenas with 420 one-day-old male Cobb broilers. At 20 days of age, all birds were radiographed and identified with an alpha-numeric metal ring in the right leg. At 40 days of age, 42 broilers previously selected as a function of bone mineral density and lesion thickness scores were again radiographed and scored, and then sacrificed. Their right tibia was removed for gross and histological examination of the growth plate. The results showed that radiographic techniques are correlated with gross and histological examination and that there was no significant differences among techniques (P>0.05. it was concluded that the use of radiographic examination to identify tibial dyschondroplasia in broilers precludes the use of bone mineral density to diagnose this condition. The non-parametric statistical Chi-square test at 5% significance level was used to analyze the results.

  2. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fiaschetti, V., E-mail: fiaschettivaleria@tin.it [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy); Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G. [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy)

    2012-11-15

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  3. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    International Nuclear Information System (INIS)

    Fiaschetti, V.; Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G.

    2012-01-01

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  4. OCT4 and SOX2 are reliable markers in detecting stem cells in odontogenic lesions

    Directory of Open Access Journals (Sweden)

    Abhishek Banerjee

    2016-01-01

    Full Text Available Context (Background: Stem cells are a unique subpopulation of cells in the human body with a capacity to initiate differentiation into various cell lines. Tumor stem cells (TSCs are a unique subpopulation of cells that possess the ability to initiate a neoplasm and sustain self-renewal. Epithelial stem cell (ESC markers such as octamer-binding transcription factor 4 (OCT4 and sex-determining region Y (SRY-box 2 (SOX2 are capable of identifying these stem cells expressed during the early stages of tooth development. Aims: To detect the expression of the stem cell markers OCT4 and SOX2 in the normal odontogenic tissues and the odontogenic cysts and tumors. Materials and Methods: Paraffin sections of follicular tissue, radicular cyst, dentigerous cyst, odontogenic keratocyst, ameloblastoma, adenomatoid odontogenic tumor, and ameloblastic carcinoma were obtained from the archives. The sections were subjected to immunohistochemical assay by the use of mouse monoclonal antibodies to OCT4 and SOX2. Statistical Analysis: The results were evaluated by descriptive analysis. Results: The results show the presence of stem cells in the normal and lesional tissues with these stem cell identifying markers. SOX2 was found to be more consistent and reliable in the detection of stem cells. Conclusion: The stem cell expressions are maintained in the tumor transformation of tissue and probably suggest that there is no phenotypic change of stem cells in progression from normal embryonic state to its tumor component. The quantification and localization reveals interesting trends that indicate the probable role of the cells in the pathogenesis of the lesions.

  5. Detection and clonal analysis of anaerobic bacteria associated to endodontic-periodontal lesions.

    Science.gov (United States)

    Pereira, Cássio V; Stipp, Rafael N; Fonseca, Douglas C; Pereira, Luciano J; Höfling, José F

    2011-12-01

    Microbial agents in root canal systems can induce periodontal inflammation. The aims of this study are to detect anaerobic microorganisms in endodontic-periodontal lesions, determine the genetic diversity among them, and assess the simultaneous colonization of the pulp and periodontal microenvironments by a single clone. Twenty-seven teeth of patients with endodontic-periodontal lesions were selected. Samples were spread on an agar-blood medium, the detection of each species was performed using a polymerase chain reaction, and the determination of the simultaneous presence of the same species in the microenvironments by one or more clones was determined using arbitrarily primed PCR. Prevotella intermedia (Pi) was the most prevalent species of the colonies in periodontal pockets, whereas Porphyromonas gingivalis (Pg) and Pi were the more prevalent in root canals. Isolates of Pi and Pg were simultaneously identified in root canals and periodontal pockets. Eighteen percent of teeth exhibited the simultaneous colonization by Pg, Tannerella forsythia (previously T. forsythensis), and Porphyromonas endodontalis in the pulp and periodontal microenvironments. The presence of these species was noted even in niches from which no colonies were isolated. Seventeen different genotypes were found in periodontal and pulp sites, with the majority of sites colonized by one or two different genotypes. A high degree of genotype similarity was found for samples of Pg isolated from only one site as well as for those isolated from both microenvironments. Different clones of Pi and Pg with a high intraspecific genotype similarity were found to colonize the same anatomic sites in endodontic-periodontal infections.

  6. Characteristic detected on computed tomography angiography predict coronary artery plaque progression in non-culprit lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Ya Hang; Zhou, Jia Zhou; Zhou, Ying; Yang, Xiaobo; Yang, Jun Jie; Chen, Yun Dai [Dept. of Cardiology, Chinese PLA General Hospital, Beijing (China)

    2017-06-15

    This study sought to determine whether variables detected on coronary computed tomography angiography (CCTA) would predict plaque progression in non-culprit lesions (NCL). In this single-center trial, we analyzed 103 consecutive patients who were undergoing CCTA and percutaneous coronary intervention (PCI) for culprit lesions. Follow-up CCTA was scheduled 12 months after the PCI, and all patients were followed for 3 years after their second CCTA examination. High-risk plaque features and epicardial adipose tissue (EAT) volume were assessed by CCTA. Each NCL stenosis grade was compared visually between two CCTA scans to detect plaque progression, and patients were stratified into two groups based on this. Logistic regression analysis was used to evaluate the factors that were independently associated with plaque progression in NCLs. Time-to-event curves were compared using the log-rank statistic. Overall, 34 of 103 patients exhibited NCL plaque progression (33%). Logistic regression analyses showed that the NCL progression was associated with a history of ST-elevated myocardial infarction (odds ratio [OR] = 5.855, 95% confidence interval [CI] = 1.391–24.635, p = 0.016), follow-up low-density lipoprotein cholesterol level (OR = 6.832, 95% CI = 2.103–22.200, p = 0.001), baseline low-attenuation plaque (OR = 7.311, 95% CI = 1.242–43.028, p = 0.028) and EAT (OR = 1.015, 95% CI = 1.000–1.029, p = 0.044). Following the second CCTA examination, major adverse cardiac events (MACEs) were observed in 12 patients, and NCL plaque progression was significantly associated with future MACEs (log rank p = 0.006). Noninvasive assessment of NCLs by CCTA has potential prognostic value.

  7. Detection of glass particles on bone lesions using SEM-EDS.

    Science.gov (United States)

    Montoriol, Romain; Guilbeau-Frugier, Céline; Chantalat, Elodie; Roumiguié, Mathieu; Delisle, Marie-Bernadette; Payré, Bruno; Telmon, Norbert; Savall, Frédéric

    2017-09-01

    The problem of identifying the wounding agent in forensic cases is recurrent. Moreover, when several tools are involved, distinguishing the origin of lesions can be difficult. Scanning electron microscopy (SEM)/energy dispersive X-ray analysis (EDS) equipment is increasingly available to the scientific and medical community, and some studies have reported its use in forensic anthropology. However, at our knowledge, no study has reported the use of SEM-EDS in forensic cases involving glass tools, whether in case reports or experiments. We performed an experimental study on human rib fragments, on which we manually created wounds using fragments of window and mirror glass. SEM-EDS was executed on samples without any further preparation on low vacuum mode, then on the same samples after defleshing them completely by boiling them. Window and mirror glass particles were detected on experimental wounds. Both had silica in their spectra, and the opaque side of the mirror contained titanium, allowing for their identification. Boiling and defleshing the bone samples involved a loss of information in terms of the number of wounds detected as positive for glass particles and in the number of glass particles detected, for both window and mirror glass. We suggest the analysis of wounds with suspected glass particles using low vacuum mode and with no defleshment by boiling.

  8. Immunohistochemical detection of hTERT in urothelial lesions: a potential adjunct to urine cytology

    Directory of Open Access Journals (Sweden)

    Khalbuss Walid

    2006-08-01

    Full Text Available Abstract Background Urine cytology has a critical role in evaluation for bladder carcinoma. Due to the low sensitivity of this technique, ancillary modalities such as the detection of markers of malignancy by immunochemistry are desirable. Promising factors in this context are components of the human telomerase enzyme complex. Telomerase repairs and extend telomeres, which when eroded beyond a critical limit trigger a senescence checkpoint. Accordingly, while absent in normal somatic cells, telomerase activity has been detected in the great majority of malignant tumor specimens tested, and so has potential value for the recognition of malignant cells in clinical specimens. Methods In this study, we investigated whether the immunohistochemical detection of the catalytic subunit of telomerase (hTERT can aid cytology in the diagnosis of bladder lesions. Findings from the retrospective evaluation of over 100 cell blocks, including urine sediments from confirmed malignant and benign conditions, were compared with routine urine cytology data. Results The presence of hTERT protein was indicative of the transformation of urothelia to a malignant phenotype. Nucleolar hTERT was expressed in 27 (93% of 29 samples obtained from patients with confirmed primary bladder cancer. Conversely, hTERT was detectable in only 3 (0.8% of 39 samples from benign conditions. The hTERT assay showed higher diagnostic sensitivity (84.8% than published urine cytology data (~65% for confirmed bladder carcinoma, however, the hTERT assay was less specific than cytology (65.2% vs. ~95% respectively. Conclusion As a highly sensitive marker, immunohistochemical hTERT detection in urine sediments represents a reliable adjunct to cytology in the accurate diagnosis of urothelial neoplasms.

  9. Multiple sclerosis

    Science.gov (United States)

    ... indwelling catheter Osteoporosis or thinning of the bones Pressure sores Side effects of medicines used to treat the ... Daily bowel care program Multiple sclerosis - discharge Preventing pressure ulcers Swallowing problems Images Multiple sclerosis MRI of the ...

  10. Computerized detection of multiple sclerosis candidate regions based on a level set method using an artificial neural network

    International Nuclear Information System (INIS)

    Kuwazuru, Junpei; Magome, Taiki; Arimura, Hidetaka; Yamashita, Yasuo; Oki, Masafumi; Toyofuku, Fukai; Kakeda, Shingo; Yamamoto, Daisuke

    2010-01-01

    Yamamoto et al. developed the system for computer-aided detection of multiple sclerosis (MS) candidate regions. In a level set method in their proposed method, they employed the constant threshold value for the edge indicator function related to a speed function of the level set method. However, it would be appropriate to adjust the threshold value to each MS candidate region, because the edge magnitudes in MS candidates differ from each other. Our purpose of this study was to develop a computerized detection of MS candidate regions in MR images based on a level set method using an artificial neural network (ANN). To adjust the threshold value for the edge indicator function in the level set method to each true positive (TP) and false positive (FP) region, we constructed the ANN. The ANN could provide the suitable threshold value for each candidate region in the proposed level set method so that TP regions can be segmented and FP regions can be removed. Our proposed method detected MS regions at a sensitivity of 82.1% with 0.204 FPs per slice and similarity index of MS candidate regions was 0.717 on average. (author)

  11. Triple dose of gadolinium-DTPA and delayed MRI in patients with benign multiple sclerosis.

    Science.gov (United States)

    Filippi, M; Capra, R; Campi, A; Colombo, B; Prandini, F; Marcianò, N; Gasparotti, R; Comi, G

    1996-01-01

    OBJECTIVES--To evaluate whether a triple dose of gadolinium-DTPA (Gd-DTPA) or delayed MRI increase the number, size, and conspicuousness of enhancing lesions in patients with benign multiple sclerosis. METHODS--T1 weighted brain MRI was carried out on 20 patients with benign multiple sclerosis (expanded disability status scale 10 years) in two sessions. In the first session, one scan was obtained before and two scans five to seven minutes and 20-30 minutes after the injection of 0.1 mmol/kg Gd-DTPA (standard dose). In the second session, six to 24 hours later, the same procedure was repeated with 0.3 mmol/kg Gd-DTPA (triple dose). RESULTS--Nine enhancing lesions were found in seven patients (35%) using the standard dose of Gd-DTPA. The numbers of enhancing lesions increased to 13 (P = 0.03) and the number of patients with such lesions to eight (40%) on the delayed standard dose scans. On the early triple dose scans, we found 19 enhancing lesions in 10 patients (50%). The number of enhancing lesions was significantly higher (P = 0.01) than that obtained with the early standard dose. The number of enhancing lesions was 18 and the number of "active" patients 11 (55%) on the delayed triple dose scans. The enhancing areas increased progressively from the early standard dose scans to the delayed triple dose scans. The contrast ratios of the lesions detected in early standard dose scans was lower than those of lesions present in the early (P = 0.01) and delayed (P = 0.04) triple dose scans. CONCLUSIONS--More enhancing lesions were detected in patients with benign multiple sclerosis with both delay of MRI and the use of triple dose of Gd-DTPA suggesting that the amount of inflammation in the lesions of such patients is mild and heterogeneous. Images PMID:8778257

  12. Serial MRI studies using gadolinium DTPA in active multiple sclerosis

    International Nuclear Information System (INIS)

    Miller, D.H.; Johnson, G.; Barnes, D.; Rudge, P.; McDonald, W.I.

    1988-01-01

    It has been suggested that blood brain barrier (BBB) impairment is a necessary early event in the pathogenesis of the multiple sclerosis (MS) lesions. To evaluate such an hypothesis in vivo would require: (1) serial imaging studies using a modality with high sensitivity for detecting plaques; (2) a contrast enhancing agent which demonstrates BBB impairment. A serial magnetic resonance imaging (MRI) study was undertaken of a group of MS patients using the contrast agent gadolinium-DTPA. As it has been suggested that T 1 and T 2 relaxation times are longer in acute than chronic MS lesions, these were also measured. 3 refs.; 1 figure

  13. Diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting trochlear ridge osteochondrosis lesions in the equine stifle.

    Science.gov (United States)

    Beccati, Francesca; Chalmers, Heather J; Dante, Sara; Lotto, Eleonora; Pepe, Marco

    2013-01-01

    Osteochondrosis lesions commonly occur on the femoral trochlear ridges in horses and radiography and ultrasonography are routinely used to diagnose these lesions. However, poor correlation has been found between radiographic and arthroscopic findings of affected trochlear ridges. Interobserver agreement for ultrasonographic diagnoses and correlation between ultrasonographic and arthroscopic findings have not been previously described. Objectives of this study were to describe diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting and grading osteochondrosis lesions of the equine trochlear ridges, using arthroscopy as the reference standard. Twenty-two horses were sampled. Two observers independently recorded radiographic and ultrasonographic findings without knowledge of arthroscopic findings. Imaging findings were compared between observers and with arthroscopic findings. Agreement between observers was moderate to excellent (κ 0.48-0.86) for detecting lesions using radiography and good to excellent (κ 0.74-0.87) for grading lesions using radiography. Agreement between observers was good to excellent (κ 0.78-0.94) for detecting lesions using ultrasonography and very good to excellent (κ 0.86-0.93) for grading lesions using ultrasonography. Diagnostic sensitivity was 84-88% for radiography and 100% for ultrasonography. Diagnostic specificity was 89-100% for radiography and 60-82% for ultrasonography. Agreement between radiography and arthroscopy was good (κ 0.64-0.78). Agreement between ultrasonography and arthroscopy was very good to excellent (κ 0.81-0.87). Findings from this study support ultrasound as a preferred method for predicting presence and severity of osteochondrosis lesions involving the femoral trochlear ridges in horses. © 2012 Veterinary Radiology & Ultrasound.

  14. Tuberous sclerosis

    Directory of Open Access Journals (Sweden)

    Krishnan S

    1996-01-01

    Full Text Available Although tuberous sclerosis has been described with a diagnostic triad, it is not present consistently in all cases. Variety of skin manifestations were reported in tuberous sclerosis. This studay was undertaken to assess the frequency of various skin changes in tuberous sclerosis. Ten consecutive cases of tuberous sclerosis were studied. Angiofibroma was the commonest cutaneous manifestation. Atypical fibroxanthoma, dermatofibroma and neurofibroma were also noticed as interesting associations.

  15. Magnetic resonance (MR) colonography in the detection of colorectal lesions: a systematic review of prospective studies

    International Nuclear Information System (INIS)

    Zijta, Frank M.; Bipat, Shandra; Stoker, Jaap

    2010-01-01

    To determine the diagnostic accuracy of MR-colonography for the detection of colorectal lesions. A comprehensive literature search was performed for comparative MR-colonography studies, published between May 1997 and February 2009, using the MEDLINE, EMBASE and Cochrane databases. We included studies if MR-colonography findings were prospectively compared with conventional colonoscopy in (a)symptomatic patients. Two reviewers independently extracted study design characteristics and data for summarising sensitivity and specificity. Heterogeneity in findings between studies was tested using I 2 test statistics. Sensitivity and specificity estimates with 95% confidence intervals (CI) were calculated on per patient basis and summary sensitivity on per polyp basis, using bivariate and univariate statistical models. Thirty-seven studies were found to be potentially relevant and 13 fulfilled the inclusion criteria. The study population comprised 1,285 patients with a mean disease prevalence of 44% (range 22-63%). Sensitivity for the detection of CRC was 100%. Significant heterogeneity was found for overall per patient sensitivity and specificity. For polyps with a size of 10 mm or larger, per patient sensitivity and specificity estimates were 88% (95% CI 63-97%; I 2 = 37%) and 99% (95% CI 95-100%; I 2 = 60%). On a per polyp basis, polyps of 10 mm or larger were detected with a sensitivity of 84% (95% CI 66-94%; I 2 = 51%). The data were too heterogeneous for polyps smaller than 6 mm and 6-9 mm. MR-colonography can accurately detect colorectal polyps more than 10 mm in size. (orig.)

  16. Effectiveness of core biopsy for screen-detected breast lesions under 10 mm: implications for surgical management.

    Science.gov (United States)

    Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley

    2017-09-01

    Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.

  17. Progression of regional grey matter atrophy in multiple sclerosis

    Science.gov (United States)

    Marinescu, Razvan V; Young, Alexandra L; Firth, Nicholas C; Jorge Cardoso, M; Tur, Carmen; De Angelis, Floriana; Cawley, Niamh; Brownlee, Wallace J; De Stefano, Nicola; Laura Stromillo, M; Battaglini, Marco; Ruggieri, Serena; Gasperini, Claudio; Filippi, Massimo; Rocca, Maria A; Rovira, Alex; Sastre-Garriga, Jaume; Geurts, Jeroen J G; Vrenken, Hugo; Wottschel, Viktor; Leurs, Cyra E; Uitdehaag, Bernard; Pirpamer, Lukas; Enzinger, Christian; Ourselin, Sebastien; Gandini Wheeler-Kingshott, Claudia A; Chard, Declan; Thompson, Alan J; Barkhof, Frederik; Alexander, Daniel C; Ciccarelli, Olga

    2018-01-01

    Abstract See Stankoff and Louapre (doi:10.1093/brain/awy114) for a scientific commentary on this article. Grey matter atrophy is present from the earliest stages of multiple sclerosis, but its temporal ordering is poorly understood. We aimed to determine the sequence in which grey matter regions become atrophic in multiple sclerosis and its association with disability accumulation. In this longitudinal study, we included 1417 subjects: 253 with clinically isolated syndrome, 708 with relapsing-remitting multiple sclerosis, 128 with secondary-progressive multiple sclerosis, 125 with primary-progressive multiple sclerosis, and 203 healthy control subjects from seven European centres. Subjects underwent repeated MRI (total number of scans 3604); the mean follow-up for patients was 2.41 years (standard deviation = 1.97). Disability was scored using the Expanded Disability Status Scale. We calculated the volume of brain grey matter regions and brainstem using an unbiased within-subject template and used an established data-driven event-based model to determine the sequence of occurrence of atrophy and its uncertainty. We assigned each subject to a specific event-based model stage, based on the number of their atrophic regions. Linear mixed-effects models were used to explore associations between the rate of increase in event-based model stages, and T2 lesion load, disease-modifying treatments, comorbidity, disease duration and disability accumulation. The first regions to become atrophic in patients with clinically isolated syndrome and relapse-onset multiple sclerosis were the posterior cingulate cortex and precuneus, followed by the middle cingulate cortex, brainstem and thalamus. A similar sequence of atrophy was detected in primary-progressive multiple sclerosis with the involvement of the thalamus, cuneus, precuneus, and pallidum, followed by the brainstem and posterior cingulate cortex. The cerebellum, caudate and putamen showed early atrophy in relapse

  18. Progression of regional grey matter atrophy in multiple sclerosis.

    Science.gov (United States)

    Eshaghi, Arman; Marinescu, Razvan V; Young, Alexandra L; Firth, Nicholas C; Prados, Ferran; Jorge Cardoso, M; Tur, Carmen; De Angelis, Floriana; Cawley, Niamh; Brownlee, Wallace J; De Stefano, Nicola; Laura Stromillo, M; Battaglini, Marco; Ruggieri, Serena; Gasperini, Claudio; Filippi, Massimo; Rocca, Maria A; Rovira, Alex; Sastre-Garriga, Jaume; Geurts, Jeroen J G; Vrenken, Hugo; Wottschel, Viktor; Leurs, Cyra E; Uitdehaag, Bernard; Pirpamer, Lukas; Enzinger, Christian; Ourselin, Sebastien; Gandini Wheeler-Kingshott, Claudia A; Chard, Declan; Thompson, Alan J; Barkhof, Frederik; Alexander, Daniel C; Ciccarelli, Olga

    2018-06-01

    See Stankoff and Louapre (doi:10.1093/brain/awy114) for a scientific commentary on this article.Grey matter atrophy is present from the earliest stages of multiple sclerosis, but its temporal ordering is poorly understood. We aimed to determine the sequence in which grey matter regions become atrophic in multiple sclerosis and its association with disability accumulation. In this longitudinal study, we included 1417 subjects: 253 with clinically isolated syndrome, 708 with relapsing-remitting multiple sclerosis, 128 with secondary-progressive multiple sclerosis, 125 with primary-progressive multiple sclerosis, and 203 healthy control subjects from seven European centres. Subjects underwent repeated MRI (total number of scans 3604); the mean follow-up for patients was 2.41 years (standard deviation = 1.97). Disability was scored using the Expanded Disability Status Scale. We calculated the volume of brain grey matter regions and brainstem using an unbiased within-subject template and used an established data-driven event-based model to determine the sequence of occurrence of atrophy and its uncertainty. We assigned each subject to a specific event-based model stage, based on the number of their atrophic regions. Linear mixed-effects models were used to explore associations between the rate of increase in event-based model stages, and T2 lesion load, disease-modifying treatments, comorbidity, disease duration and disability accumulation. The first regions to become atrophic in patients with clinically isolated syndrome and relapse-onset multiple sclerosis were the posterior cingulate cortex and precuneus, followed by the middle cingulate cortex, brainstem and thalamus. A similar sequence of atrophy was detected in primary-progressive multiple sclerosis with the involvement of the thalamus, cuneus, precuneus, and pallidum, followed by the brainstem and posterior cingulate cortex. The cerebellum, caudate and putamen showed early atrophy in relapse-onset multiple

  19. Skin scoring in systemic sclerosis

    DEFF Research Database (Denmark)

    Zachariae, Hugh; Bjerring, Peter; Halkier-Sørensen, Lars

    1994-01-01

    Forty-one patients with systemic sclerosis were investigated with a new and simple skin score method measuring the degree of thickening and pliability in seven regions together with area involvement in each region. The highest values were, as expected, found in diffuse cutaneous systemic sclerosis...... (type III SS) and the lowest in limited cutaneous systemic sclerosis (type I SS) with no lesions extending above wrists and ancles. A positive correlation was found to the aminoterminal propeptide of type III procollagen, a serological marker for synthesis of type III collagen. The skin score...

  20. Noninvasive detection of macrophages in atherosclerotic lesions by computed tomography enhanced with PEGylated gold nanoparticles

    Directory of Open Access Journals (Sweden)

    Qin J

    2014-12-01

    Full Text Available Jinbao Qin,1,* Chen Peng,2,* Binghui Zhao,2,* Kaichuang Ye,1 Fukang Yuan,1 Zhiyou Peng,1 Xinrui Yang,1 Lijia Huang,1 Mier Jiang,1 Qinghua Zhao,3 Guangyu Tang,2 Xinwu Lu1,4 1Department of Vascular Surgery, Shanghai Ninth People’s Hospital Affiliated to Shanghai JiaoTong University, School of Medicine; 2Department of Radiology, Shanghai Tenth People’s Hospital Affiliated to Tongji University, School of Medicine; 3Department of Orthopaedics, Shanghai First People’s Hospital, School of Medicine, Shanghai Jiao Tong University; 4Vascular Center of Shanghai JiaoTong University, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: Macrophages are becoming increasingly significant in the progression of atherosclerosis (AS. Molecular imaging of macrophages may improve the detection and characterization of AS. In this study, dendrimer-entrapped gold nanoparticles (Au DENPs with polyethylene glycol (PEG and fluorescein isothiocyanate (FI coatings were designed, tested, and applied as contrast agents for the enhanced computed tomography (CT imaging of macrophages in atherosclerotic lesions. Cell counting kit-8 assay, fluorescence microscopy, silver staining, and transmission electron microscopy revealed that the FI-functionalized Au DENPs are noncytotoxic at high concentrations (3.0 µM and can be efficiently taken up by murine macrophages in vitro. These nanoparticles were administered to apolipoprotein E knockout mice as AS models, which demonstrated that the macrophage burden in atherosclerotic areas can be tracked noninvasively and dynamically three-dimensionally in live animals using micro-CT. Our findings suggest that the designed PEGylated gold nanoparticles are promising biocompatible nanoprobes for the CT imaging of macrophages in atherosclerotic lesions and will provide new insights into the pathophysiology of AS and other concerned inflammatory diseases. Keywords: atherosclerosis, CT, in vivo

  1. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  2. Detection and excision of non-palpable breast lesions by radio guided surgery and air injection for radiological control

    International Nuclear Information System (INIS)

    Machado, Rafael Henrique Szymanski; Gutfilen, Bianca; Fonseca, Lea Mirian Barbosa da

    2005-01-01

    Purpose: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. Methods: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with 99m Tc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. Results: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS lesions, in 31.5% (6/19) of the 4 BI-RADS and in 66.6% (2/3) of the 5 BI-RADS. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). Conclusions: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients. (author)

  3. Oral Dalfampridine Improves Standing Balance Detected at Static Posturography in Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Luca Prosperini

    2014-01-01

    Full Text Available We report a 14-week post-marketing experience on 20 patients with multiple sclerosis (MS who started prolonged-release (PR oral dalfampridine 10 mg twice daily according to European Medicine Agency criteria. They underwent serial static posturography assessments and the dizziness handicap inventory (DHI to investigate whether PR dalfampridine could impact standing balance and self-reported perception of balance. The incidence of accidental falls per person per month was also recorded throughout the study. Eight (40% patients, who had a relevant improvement in walking speed, were defined as treatment responders. They showed a significant improvement of standing balance (with respect to pretreatment assessment when contrasted with 12 (60% nonresponders (F[4,15] = 3.959, P=0.027. No significant changes in DHI score, as well as in its functional, physical, and emotional subscales, were found in both responders and nonresponders at the end of study (all P values are ≥0.2. Treatment response did not affect the incidence of accidental falls. Future studies based on larger sample sizes, and with longer followup, are required to confirm the beneficial effect of PR dalfampridine on standing balance.

  4. Exhaled Breath Markers for Nonimaging and Noninvasive Measures for Detection of Multiple Sclerosis.

    Science.gov (United States)

    Broza, Yoav Y; Har-Shai, Lior; Jeries, Raneen; Cancilla, John C; Glass-Marmor, Lea; Lejbkowicz, Izabella; Torrecilla, José S; Yao, Xuelin; Feng, Xinliang; Narita, Akimitsu; Müllen, Klaus; Miller, Ariel; Haick, Hossam

    2017-11-15

    Multiple sclerosis (MS) is the most common chronic neurological disease affecting young adults. MS diagnosis is based on clinical characteristics and confirmed by examination of the cerebrospinal fluids (CSF) or by magnetic resonance imaging (MRI) of the brain or spinal cord or both. However, neither of the current diagnostic procedures are adequate as a routine tool to determine disease state. Thus, diagnostic biomarkers are needed. In the current study, a novel approach that could meet these expectations is presented. The approach is based on noninvasive analysis of volatile organic compounds (VOCs) in breath. Exhaled breath was collected from 204 participants, 146 MS and 58 healthy control individuals. Analysis was performed by gas-chromatography mass-spectrometry (GC-MS) and nanomaterial-based sensor array. Predictive models were derived from the sensors, using artificial neural networks (ANNs). GC-MS analysis revealed significant differences in VOC abundance between MS patients and controls. Sensor data analysis on training sets was able to discriminate in binary comparisons between MS patients and controls with accuracies up to 90%. Blinded sets showed 95% positive predictive value (PPV) between MS-remission and control, 100% sensitivity with 100% negative predictive value (NPV) between MS not-treated (NT) and control, and 86% NPV between relapse and control. Possible links between VOC biomarkers and the MS pathogenesis were established. Preliminary results suggest the applicability of a new nanotechnology-based method for MS diagnostics.

  5. Application of diffusional kurtosis imaging to detect occult brain damage in multiple sclerosis and neuromyelitis optica.

    Science.gov (United States)

    Qian, Wenshu; Chan, Koon Ho; Hui, Edward S; Lee, Chi Yan; Hu, Yong; Mak, Henry Ka-Fung

    2016-11-01

    Multiple sclerosis (MS) and neuromyelitis optica (NMO) are two common types of inflammatory demyelinating disease of the central nervous system. Early distinction of NMO from MS is crucial but quite challenging. In this study, 13 NMO spectrum disorder patients (Expanded Disability Status Scale (EDSS) of 3.0 ± 1.7, ranging from 2 to 6.5; disease duration of 5.3 ± 4.7 years), 17 relapsing-remitting MS patients (EDSS of 2.6 ± 1.4, ranging from 1 to 5.5; disease duration of 7.9 ± 7.8 years) and 18 healthy volunteers were recruited. Diffusional kurtosis imaging was employed to discriminate NMO and MS patients at the early or stable stage from each other, and from healthy volunteers. The presence of alterations in diffusion and diffusional kurtosis metrics in normal-appearing white matter (NAWM) and diffusely increased mean diffusivity (MD) in the cortical normal-appearing gray matter (NAGM) favors the diagnosis of MS rather than NMO. Meanwhile, normal diffusivities and kurtosis metrics in all NAWM as well as increases in MD in the frontal and temporal NAGM suggest NMO. Our results suggest that diffusion and diffusional kurtosis metrics may well aid in discriminating the two diseases. Copyright © 2016 John Wiley & Sons, Ltd.

  6. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    Science.gov (United States)

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the

  7. Assessment of enamel-dentin caries lesions detection using bitewing PSP digital images

    Directory of Open Access Journals (Sweden)

    Marianna Guanaes Gomes Torres

    2011-10-01

    Full Text Available OBJECTIVES: The aim of this study was to evaluate the detection of enamel-dentin occlusal caries using photostimulable phosphor plates. MATERIAL AND METHODS: The ability to detect enamel-dentin occlusal caries in 607 premolars and molars from 47 patients between 10 and 18 years old, referred to the School of Dentistry of the Federal University of Bahia, Brazil, was evaluated based on clinical and radiographic examinations, using the criteria proposed in a previous study. A total of 156 bitewing digital images were obtained using Digora® (Soredex Medical Systems, Helsinki, Finland phosphor plates. The plates were scanned and the images were captured and displayed on a computer screen. Image evaluation was done using Digora® for Windows 2.1 software, Soredex®. The radiologists were allowed to use enhancement tools to obtain better visibility during scoring of the teeth based on the radiographic criteria proposed in a previous study. Descriptive analysis and chi-squared proportion tests were done at 5% significance level. RESULTS: The results of clinical examination showed a higher prevalence of teeth with a straight dark line or demineralization of the occlusal fissure (score 1 and a lower prevalence of sealed teeth (score 5. In the bitewing digital images, 47 teeth presented visible radiolucency, circumscribed, in dentin under occlusal enamel (enamel-dentin caries lesions. CONCLUSIONS: Correlating the clinical and radiographic findings, it was found that in the majority of teeth diagnosed by radiographic images as having enamel-dentin caries, no caries could be detected by clinical examination.

  8. Early dynamic 18F-FDG PET to detect hyperperfusion in hepatocellular carcinoma liver lesions.

    Science.gov (United States)

    Schierz, Jan-Henning; Opfermann, Thomas; Steenbeck, Jörg; Lopatta, Eric; Settmacher, Utz; Stallmach, Andreas; Marlowe, Robert J; Freesmeyer, Martin

    2013-06-01

    In addition to angiographic data on vascularity and vascular access, demonstration of hepatocellular carcinoma (HCC) liver nodule hypervascularization is a prerequisite for certain intrahepatic antitumor therapies. Early dynamic (ED) (18)F-FDG PET/CT could serve this purpose when the current standard method, contrast-enhanced (CE) CT, or other CE morphologic imaging modalities are unsuitable. A recent study showed ED (18)F-FDG PET/CT efficacy in this setting but applied a larger-than-standard (18)F-FDG activity and an elaborate protocol likely to hinder routine use. We developed a simplified protocol using standard activities and easily generated visual and descriptive or quantitative endpoints. This pilot study assessed the ability of these endpoints to detect HCC hyperperfusion and, thereby, evaluated the suitability in of the protocol everyday practice. Twenty-seven patients with 34 HCCs (diameter ≥ 1.5 cm) with hypervascularization on 3-phase CE CT underwent liver ED (18)F-FDG PET for 240 s, starting with (18)F-FDG (250-MBq bolus injection). Four frames at 15-s intervals, followed by 3 frames at 60-s intervals were reconstructed. Endpoints included focal tracer accumulation in the first 4 frames (60 s), subsequent focal washout, and visual and quantitative differences between tumor and liver regions of interest in maximum and mean ED standardized uptake value (ED SUVmax and ED SUVmean, respectively) 240-s time-activity curves. All 34 lesions were identified by early focal (18)F-FDG accumulation and faster time-to-peak ED SUVmax or ED SUVmean than in nontumor tissue. Tumor peak ED SUVmax and ED SUVmean exceeded liver levels in 85% and 53%, respectively, of lesions. Nadir tumor signal showed no consistent pattern relative to nontumor signal. HCC had a significantly shorter time to peak and significantly faster rate to peak for both ED SUVmax and ED SUVmean curves and a significantly higher peak ED SUVmax but not peak ED SUVmean than the liver. This pilot study

  9. Model observer for assessing digital breast tomosynthesis for multi-lesion detection in the presence of anatomical noise

    Science.gov (United States)

    Wen, Gezheng; Markey, Mia K.; Miner Haygood, Tamara; Park, Subok

    2018-02-01

    Model observers are widely used in task-based assessments of medical image quality. The presence of multiple abnormalities in a single set of images, such as in multifocal multicentric breast cancer (MFMC), has an immense clinical impact on treatment planning and survival outcomes. Detecting multiple breast tumors is challenging as MFMC is relatively uncommon, and human observers do not know the number or locations of tumors a priori. Digital breast tomosynthesis (DBT), in which an x-ray beam sweeps over a limited angular range across the breast, has the potential to improve the detection of multiple tumors. However, prior studies of DBT image quality all focus on unifocal breast cancers. In this study, we extended our 2D multi-lesion (ML) channelized Hotelling observer (CHO) into a 3D ML-CHO that detects multiple lesions from volumetric imaging data. Then we employed the 3D ML-CHO to identify optimal DBT acquisition geometries for detection of MFMC. Digital breast phantoms with multiple embedded synthetic lesions were scanned by simulated DBT scanners of different geometries (wide/narrow angular span, different number of projections per scan) to simulate MFMC cases. With new implementations of 3D partial least squares (PLS) and modified Laguerre-Gauss (LG) channels, the 3D ML-CHO made detection decisions based upon the overall information from individual DBT slices and their correlations. Our evaluation results show that: (1) the 3D ML-CHO could achieve good detection performance with a small number of channels, and 3D PLS channels on average outperform the counterpart LG channels; (2) incorporating locally varying anatomical backgrounds and their correlations as in the 3D ML-CHO is essential for multi-lesion detection; (3) the most effective DBT geometry for detection of MFMC may vary when the task of clinical interest changes, and a given DBT geometry may not yield images that are equally informative for detecting MF, MC, and unifocal cancers.

  10. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    International Nuclear Information System (INIS)

    Zhou, Yifang; Scott, Alexander II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-01-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R 2   >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented. (paper)

  11. Continuously moving table MRI with sliding multislice for rectal cancer staging: Image quality and lesion detection

    International Nuclear Information System (INIS)

    Baumann, Tobias; Ludwig, Ute; Pache, Gregor; Fautz, Hans-Peter; Kotter, Elmar; Langer, Mathias; Schaefer, Oliver

    2010-01-01

    Purpose: To determine image quality and lesion detection of sliding multislice (SMS), a recently developed moving table MRI technique, in patients with rectal cancer. Materials and methods: Twenty-seven paired SMS (Avanto, Siemens Medical Solutions) and MDCT (Sensation 64, Siemens Medical Solutions) examinations of abdomen and pelvis were performed in patients with rectal cancer and compared for detection of liver, lymph node and bone metastases by two independent observers. A contrast-enhanced, fat saturated 2D gradient echo sequence (TE, 2.0 ms; TR, 102 ms; slice, 5 mm) was acquired with SMS and a standard contrast-enhanced protocol (100 ml 2.5 ml/s; slice, 5 mm) was used for abdominal MDCT. Standard of reference consisted of a consensus evaluation of SMS, MDCT, and all available follow-up examinations after a period of 6 months. Artifact burden and image quality of SMS was assessed in comparison to stationary gradient echo sequences obtained in an age-matched group of 27 patients. Results: Whereas SMS achieved a mean quality score of 3.65 (scale, 0-4) for the liver, representing very good diagnostic properties, strong breathing artifacts in the intestinal region were observed in 19 cases by both observers. The retroperitoneum still achieved a mean quality score of 3.52, although breathing artifacts were noted in 12 and 15 cases (observers 1 and 2, respectively). The sensitivities of SMS to detect hepatic metastases were 91.2% and 94.1% for both observers, respectively, compared to 98.5%/98.5% for MDCT. The sensitivities for lymph node metastases were 87.5%/81.3% for SMS compared to 78.1%/81.3% for MDCT. The sensitivities for bone metastases were 91.7%/100% for SMS compared to 8.3%/16.7% for MDCT. Conclusion: With slightly reduced image quality in the intestinal region, SMS exhibits equal detection of lymph node and liver metastases compared to MDCT. SMS MRI proved to be superior to MDCT in detection of bone metastases.

  12. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    Science.gov (United States)

    Zhou, Yifang; Scott, Alexander, II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-10-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R^2  >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented.

  13. Brain MRI screening showing evidences of early central nervous system involvement in patients with systemic sclerosis.

    Science.gov (United States)

    Mohammed, Reem Hamdy A; Sabry, Yousriah Y; Nasef, Amr A

    2011-05-01

    Systemic sclerosis is a multisystem autoimmune collagen disease where structural and functional abnormalities of small blood vessels prevail. Transient ischemic attacks, ischemic stroke, and hemorrhage have been reported as primary consequence of vascular central nervous system affection in systemic sclerosis. Magnetic resonance imaging is considered to be the most sensitive diagnostic technique for detecting symptomatic and asymptomatic lesions in the brain in cases of multifocal diseases. The objective of this study is to detect subclinical as well as clinically manifest cerebral vasculopathy in patients with systemic sclerosis using magnetic resonance imaging. As much as 30 female patients with systemic sclerosis aged 27-61 years old, with disease duration of 1-9 years and with no history of other systemic disease or cerebrovascular accidents, were enrolled. Age-matched female control group of 30 clinically normal subjects, underwent brain magnetic resonance examination. Central nervous system (CNS) involvement in the form of white matter hyperintense foci of variable sizes were found in significantly abundant forms in systemic sclerosis patients on magnetic resonance evaluation than in age-related control group, signifying a form of CNS vasculopathy. Such foci showed significant correlation to clinical features of organic CNS lesion including headaches, fainting attacks and organic depression as well as to the severity of peripheral vascular disease with insignificant correlation with disease duration. In conclusion, subclinical as well as clinically manifest CNS ischemic vasculopathy is not uncommon in systemic sclerosis patients and magnetic resonance imaging is considered a sensitive noninvasive screening tool for early detection of CNS involvement in patients with systemic sclerosis.

  14. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    Directory of Open Access Journals (Sweden)

    Size Wu

    2016-01-01

    Full Text Available Purpose: The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. Methods: A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. Results: The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501 and 94.2% (389/413, respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177 vs. liver without fat infiltration (389/413 (P=0.277; mild fatty liver (162/177 vs. moderate fatty liver (190/212 (P=0.604; mild fatty liver (162/177 vs. severe fatty liver (83/112 (P<0.001; moderate fatty liver (190/212 vs. liver without fat infiltration (389/413 (P=0.051; moderate fatty liver (190/212 vs. severe fatty liver (83/112 (P<0.001; severe fatty liver (83/112 vs. liver without fat infiltration (389/413 (P<0.001; and fatty liver (435/501 vs. liver without fat infiltration (389/413 (P<0.001. Conclusion: Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis.

  15. Neuroimage in neuroecthodermic diseases Part II: Tuberous Sclerosis

    International Nuclear Information System (INIS)

    Menor, F.; Marti-Bonmati, L.; Poyatos, C.; Cortina, H.; Esteban, J.M.; Vilar, J.

    1993-01-01

    A prospective clinicoradiological study has been carried out in 36 patients with tuberous sclerosis. The neuroimaging studies detected some type of disorder in 94% of patients, contributing significantly to the positive diagnosis of the disease. CT was better for viewing periventricular nodules, while MR was more reliable in disclosing the number and location of cortical and white matter lesions. The use of gadolinium-DTPA in MR demonstrated frequent uptake by the periventricular nodules which was exceptional in the cortical and subcortical lesions. The use of contrast, both in CT and in MR, enhanced the images of the 7 presumed giant-cell astrocytomas detected in 6 patients. Uptake by the tumors was always much greater than that observed in the nodules, being and important criterion for the differentiation between nodules and small tumors. The appearance and topography of these CNS lesions can be reasonably well explained by considering the disease to be a disorder of the migration of dysgenic cells. We have found no consistent correlation between the neuroradiological findings and the clinical evolution of the patients. MR and CT are similarly useful in the diagnosis of tuberous sclerosis. Given that MR is more effective in the detection of the set of intracranial lesions, it could be used as the initial technique, resorting to CT in those cases in which the clinical evidence is highly suggestive and the MR study is negative. Periodic MR control is not justified unless there is suspicion of tumor implantation or growth

  16. Extirpation of a cranial lesion radio guided by scintigraphy and intraoperative detection

    International Nuclear Information System (INIS)

    Concha Julio, Enrique; Basuri, Luciano; Otayza, Felipe; Neubauer, Sonia; Mena, Ismael; Arteaga, Maria Paz

    2005-01-01

    A skull lesion may be difficult to localize, specially a small one that is not evident on the external surface. In this paper, we describe the localization and extirpation aided by intraoperative radio guidance of a 2 cm lesion compromising the internal aspect of the posterior temporal bone. The radiological expression of this lesion was poor, both on the plain radiograph's and on the computed tomography, making the intraoperative radiology and the navigation aided by computed tomography useless. The lesion was extirpated in block and the skull repaired. The biopsy confirmed a Paget's disease. There were not surgical complications (au)

  17. The patient had a normal magnetic resonance imaging and temporal lobe epilepsy secondary to a porencephalic cyst but showed structural lesions (hippocampal sclerosis)☆

    Science.gov (United States)

    Matsubara, Teppei; Ayuzawa, Satoshi; Aoki, Tsukasa; Fujiomto, Ayataka; Osuka, Satoru; Matsumura, Akira

    2013-01-01

    Patients with a porencephalic cyst frequently develop intractable temporal lobe epilepsy (TLE). We report a surgically-treated male patient with intractable mesial TLE (mTLE) secondary to a porencephalic cyst. Although magnetic resonance imaging showed no hippocampal abnormalities, long-term video-electrocorticography revealed seizure onset discharges in the hippocampus. Temporal lobectomy brought an end to the patient's seizures. Hippocampal sclerosis was histopathologically confirmed (dual pathology). Careful evaluation of hippocampal epileptogenicity is required, and temporal lobectomy, which is less invasive than hemispherectomy, can be a treatment of choice for patients with mTLE secondary to a porencephalic cyst. PMID:25667851

  18. The performance of multimodal hyperspectral spectroscopy in the detection of precancerous cervical lesions

    Science.gov (United States)

    Trahmono; Lusiana, N.; Indarti, J.

    2017-08-01

    The aim of this study was to compare the performance of multimodal hyperspectral spectroscopy (MHS), which combines fluorescence and reflectance spectroscopy, with that of conventional laboratory-based screening tests, such as the Papanicolaou (Pap) smear test and human papilloma virus (HPV) DNA test, for detecting precancerous lesions of the cervix. The study utilized a cross-sectional design, and the kappa test was used in the analytical assessment. MHS scans were obtained from a sample of 70 consecutive patients, followed by sample collection for Pap and HPV DNA analysis and colposcopy referral, if indicated. Of the 70 patients evaluated, the results of cervical spectroscopy were normal in 38 (54.3%) patients, and they were abnormal in 32 (45.7%) patients. Based on the cytology results, 45 (64.3%) samples were normal, and 25 (35.7%) samples were abnormal. According to the results of the HPV DNA test, 47 (67.14%) samples were normal, and 17 (24.28%) samples were abnormal. Based on the results of the kappa test, the agreement between MHS and cytology was 0.793 (p < 0.001). The agreement between MHS and the HPV DNA test was 0.195 (p = 0.086), and the agreement between MHS and colposcopy was 0.479 (p < 0.001).

  19. Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Charlotte S. van der [Radboud University Medical Centre, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands); Koopman, Danielle [University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Rijnsdorp, Sjoerd; Arends, Albert J. [Catharina Hospital, Department of Medical Physics, Eindhoven (Netherlands); Boellaard, Ronald [University of Groningen, University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Dalen, Jorn A. van [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Isala, Department of Medical Physics, Zwolle (Netherlands); Lubberink, Mark [Uppsala University, Department of Surgical Sciences, Uppsala (Sweden); Uppsala University Hospital, Department of Medical Physics, Uppsala (Sweden); Willemsen, Antoon T.M. [University of Groningen, University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Visser, Eric P. [Radboud University Medical Centre, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands)

    2017-08-15

    In recent years, there have been multiple advances in positron emission tomography/computed tomography (PET/CT) that improve cancer imaging. The present generation of PET/CT scanners introduces new hardware, software, and acquisition methods. This review describes these new developments, which include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent {sup 18}F-fluorodeoxyglucose (FDG) activity. Also, hardware developments such as continuous bed motion (CBM), (digital) solid-state photodetectors and combined PET and magnetic resonance (MR) systems are explained. These novel techniques have a significant impact on cancer imaging, as they result in better image quality, improved small lesion detectability, and more accurate quantification of radiopharmaceutical uptake. This influences cancer diagnosis and staging, as well as therapy response monitoring and radiotherapy planning. Finally, the possible impact of these developments on the European Association of Nuclear Medicine (EANM) guidelines and EANM Research Ltd. (EARL) accreditation for FDG-PET/CT tumor imaging is discussed. (orig.)

  20. Bond strength to dentin with artificial carious lesions: influence of caries detecting dye.

    Science.gov (United States)

    Palma, R G; Turbino, M L; Matson, E; Powers, J M

    1998-06-01

    To evaluate the influence of dyes for caries detection on tensile bond strength of adhesive materials to artificial carious dentin. Buccal and lingual enamel of human molars were removed leaving intact dentin surfaces. The entire surface of each specimen was covered with nail varnish, keeping a window area of 4 x 4 mm. Artificial carious lesions were induced with acidified gel. Three dyes (0.5% basic fuchsin; Caries Finder and Cari-D-Tect) were used according to manufacturers' recommendations. Specimens were etched with 35% phosphoric acid for 20 s, washed and dried, leaving a wet dentin surface. The adhesive system (Prime & Bond 2.0) was applied in two layers and light-cured. Restorative materials (TPH Spectrum, Dyract, Advance) were bonded using a 3-mm diameter inverted-cone mold. Control groups were made without dye. Eight samples were tested for each group. After 24 hrs of storage in distilled water, the samples were debonded using a testing machine at 0.5 mm/min crosshead speed. ANOVA and Tukey-Kramer test showed that TPH Spectrum (0.73 MPa) and Dyract (0.74 MPa) had similar bond strengths, and both were higher than Advance (0.0 MPa), which was statistically different (P strength for any tested materials.

  1. Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET

    International Nuclear Information System (INIS)

    Vos, Charlotte S. van der; Koopman, Danielle; Rijnsdorp, Sjoerd; Arends, Albert J.; Boellaard, Ronald; Dalen, Jorn A. van; Lubberink, Mark; Willemsen, Antoon T.M.; Visser, Eric P.

    2017-01-01

    In recent years, there have been multiple advances in positron emission tomography/computed tomography (PET/CT) that improve cancer imaging. The present generation of PET/CT scanners introduces new hardware, software, and acquisition methods. This review describes these new developments, which include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent 18 F-fluorodeoxyglucose (FDG) activity. Also, hardware developments such as continuous bed motion (CBM), (digital) solid-state photodetectors and combined PET and magnetic resonance (MR) systems are explained. These novel techniques have a significant impact on cancer imaging, as they result in better image quality, improved small lesion detectability, and more accurate quantification of radiopharmaceutical uptake. This influences cancer diagnosis and staging, as well as therapy response monitoring and radiotherapy planning. Finally, the possible impact of these developments on the European Association of Nuclear Medicine (EANM) guidelines and EANM Research Ltd. (EARL) accreditation for FDG-PET/CT tumor imaging is discussed. (orig.)

  2. Descriptive data on cancerous lung lesions detected by auto-fluorescence bronchoscope: A five-year study

    Directory of Open Access Journals (Sweden)

    Asmitananda Thakur

    2012-01-01

    Full Text Available Background: Auto-fluorescence bronchoscopy (AFB has been used for the identification and localization of intra-epithelial pre-neoplastic and neoplastic lesions within the bronchus. Objectives: To determine the applicability of AFB for the detection and localization of precancerous and cancerous lesions, in addition to analyzing the morphologic presentation, their association to histological type and the variation between genders. Methods: A five-year study involving 4983 patients, who underwent routine bronchoscopy [B] examination in a local tertiary teaching hospital, was done. The B examination was performed under intratracheal lidocaine, and samples were obtained using suitable approach. One thousand four hundred and eighty-five pathologically confirmed lung cancer patients were included in the study. The following parameters were studied: Morphological presentation, biopsy sites, histology. Differences between the groups were analyzed using Chi square test. Result: One thousand four hundred and eighty-five patients who had hyperplasia or neoplastic lesions were further confirmed as lung cancer pathologically. Lung cancer was more commonly found in the right lung (51.58% vs. 42.82%. The lesion occurred more frequently in the upper lobe than the lower lobe (44.17% vs. 22.42%. Male patients with squamous cell carcinoma showed upper lobe involvement more commonly, while the left main bronchus was more commonly involved in female patients. Adenocarcinoma mostly involved lesion of the upper lobe. Squamous cell carcinoma and small cell carcinoma were the major proliferative types (80.15% and 76.16% respectively. Conclusion: AFB is efficient in the detection of pre-invasive and invasive lung lesions. The morphological presentation is associated to the histological type. There is variation in the presentation and histology of cancerous lung lesions between genders.

  3. Magnetic resonance imaging in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo

    1989-01-01

    Magnetic resonance imaging (MRI) of the brain was performed in a total of 45 patients with multiple sclerosis (MS), comprising 27 with brain symptoms and 18 without it. The results were compared with X-ray computed tomography (CT). Some of the 45 MS patients were also examined by neurophysiological studies for comparison. MRI showed demyelinating plaques of the brain in a total of 31 patients (69%) - 20 symptomatic and 11 asymptomatic patients. For symptomatic patients, MRI was capable of detecting brain lesions in 6 (86%) of 7 acute stage patients and 14 (70%) of 20 non-acute stage patients. It was also capable of detecting brain lesions in 21 (70%) of 30 clinically definite MR patients and 10 (67%) of 15 clinically probable MS patients. Concurrently available X-ray CT revealed brain lesions in 9 symptomatic patients (33%) and one asymptomatic patient (6%). Visual evoked potentials examined in 31 patients showed abnormality in one (11%) of 9 patients without symptoms of optic neuritis and all (100%) of the other 22 patients with symptoms. In 19 evaluable patients, auditory brainstem responses were abnormal in one (11%) of 9 patients without brainstem symptoms and 3 (30%) of 10 patients with symptoms. MRI of the brain was far superior to X-ray CT, visual evoked potentials and auditory brainstem responses in detecting clinically unsuspected lesions. We proposed new diagnostic criteria including MRI findings of the brain in the Japanese MS diagnostic criteria. MRI of the spinal cord was performed in 12 MS patients with spinal cord symptoms by sagittal and coronal images. It demonstrated demyelinating lesions within the cervical and superior thoracic cord in 8 MS acute stage patients. Spinal cord lesions were longitudinally continuous as long as many spinal segments, with swelling in 6 patients and atrophy in 2 patients. MRI of spinal cord was useful in deciding superior and inferior limits of cord lesions and in visualizing cord swelling or atrophy. (Namekawa, K)

  4. Tissue resonance interaction accurately detects colon lesions: A double-blind pilot study.

    Science.gov (United States)

    Dore, Maria P; Tufano, Marcello O; Pes, Giovanni M; Cuccu, Marianna; Farina, Valentina; Manca, Alessandra; Graham, David Y

    2015-07-07

    To investigated the performance of the tissue resonance interaction method (TRIM) for the non-invasive detection of colon lesions. We performed a prospective single-center blinded pilot study of consecutive adults undergoing colonoscopy at the University Hospital in Sassari, Italy. Before patients underwent colonoscopy, they were examined by the TRIMprobe which detects differences in electromagnetic properties between pathological and normal tissues. All patients had completed the polyethylene glycol-containing bowel prep for the colonoscopy procedure before being screened. During the procedure the subjects remained fully dressed. A hand-held probe was moved over the abdomen and variations in electromagnetic signals were recorded for 3 spectral lines (462-465 MHz, 930 MHz, and 1395 MHz). A single investigator, blind to any clinical information, performed the test using the TRIMprob system. Abnormal signals were identified and recorded as malignant or benign (adenoma or hyperplastic polyps). Findings were compared with those from colonoscopy with histologic confirmation. Statistical analysis was performed by χ(2) test. A total of 305 consecutive patients fulfilling the inclusion criteria were enrolled over a period of 12 months. The most frequent indication for colonoscopy was abdominal pain (33%). The TRIMprob was well accepted by all patients; none spontaneously complained about the procedure, and no adverse effects were observed. TRIM proved inaccurate for polyp detection in patients with inflammatory bowel disease (IBD) and they were excluded leaving 281 subjects (mean age 59 ± 13 years; 107 males). The TRIM detected and accurately characterized all 12 adenocarcinomas and 135/137 polyps (98.5%) including 64 adenomatous (100%) found. The method identified cancers and polyps with 98.7% sensitivity, 96.2% specificity, and 97.5% diagnostic accuracy, compared to colonoscopy and histology analyses. The positive predictive value was 96.7% and the negative predictive

  5. Inter- and intraobserver variability of MR arthrography in the detection and classification of superior labral anterior posterior (SLAP) lesions: evaluation in 78 cases with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Holzapfel, Konstantin; Waldt, Simone; Bruegel, Melanie; Rummeny, Ernst J.; Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Klinikum rechts der Isar, Munich (Germany); Paul, Jochen; Imhoff, Andreas B. [Technische Universitaet Muenchen, Department of Sports Orthopedics, Klinikum rechts der Isar, Munich (Germany); Heinrich, Petra [Technische Universitaet Muenchen, Institute of Medical Statistics and Epidemiology, Klinikum rechts der Isar, Munich (Germany)

    2010-03-15

    The purpose of this study was to determine inter- and intraobserver variability of MR arthrography of the shoulder in the detection and classification of superior labral anterior posterior (SLAP) lesions. MR arthrograms of 78 patients who underwent MR arthrography before arthroscopy were retrospectively analysed by three blinded readers for the presence and type of SLAP lesions. MR arthrograms were reviewed twice by each reader with a time interval of 4 months between the two readings. Inter- and intraobserver agreement for detection and classification of SLAP lesions were calculated using {kappa} coefficients. Arthroscopy confirmed 48 SLAP lesions: type I (n = 4), type II (n = 37), type III (n = 3), type IV (n = 4). Sensitivity and specificity for detecting SLAP lesions with MR arthrography for each reader were 88.6%/93.3%, 90.9%/80.0% and 86.4%/76.7%. MR arthrographic and arthroscopic grading were concurrent for 72.7%, 68.2% and 70.5% of SLAP lesions for readers 1-3, respectively. Interobserver agreement was excellent ({kappa} = 0.82) for detection and substantial ({kappa} = 0.63) for classification of SLAP lesions. For each reader intraobserver agreement was excellent for detection ({kappa} = 0.93, {kappa} = 0.97, {kappa} = 0.97) and classification ({kappa} = 0.94, {kappa} = 0.84, {kappa} = 0.93) of SLAP lesions. MR arthrography allows reliable and accurate detection of SLAP lesions. In addition, SLAP lesions can be diagnosed and classified with substantial to excellent inter- and intraobserver agreement. (orig.)

  6. Inter- and intraobserver variability of MR arthrography in the detection and classification of superior labral anterior posterior (SLAP) lesions: evaluation in 78 cases with arthroscopic correlation

    International Nuclear Information System (INIS)

    Holzapfel, Konstantin; Waldt, Simone; Bruegel, Melanie; Rummeny, Ernst J.; Woertler, Klaus; Paul, Jochen; Imhoff, Andreas B.; Heinrich, Petra

    2010-01-01

    The purpose of this study was to determine inter- and intraobserver variability of MR arthrography of the shoulder in the detection and classification of superior labral anterior posterior (SLAP) lesions. MR arthrograms of 78 patients who underwent MR arthrography before arthroscopy were retrospectively analysed by three blinded readers for the presence and type of SLAP lesions. MR arthrograms were reviewed twice by each reader with a time interval of 4 months between the two readings. Inter- and intraobserver agreement for detection and classification of SLAP lesions were calculated using κ coefficients. Arthroscopy confirmed 48 SLAP lesions: type I (n = 4), type II (n = 37), type III (n = 3), type IV (n = 4). Sensitivity and specificity for detecting SLAP lesions with MR arthrography for each reader were 88.6%/93.3%, 90.9%/80.0% and 86.4%/76.7%. MR arthrographic and arthroscopic grading were concurrent for 72.7%, 68.2% and 70.5% of SLAP lesions for readers 1-3, respectively. Interobserver agreement was excellent (κ = 0.82) for detection and substantial (κ = 0.63) for classification of SLAP lesions. For each reader intraobserver agreement was excellent for detection (κ = 0.93, κ = 0.97, κ = 0.97) and classification (κ = 0.94, κ = 0.84, κ = 0.93) of SLAP lesions. MR arthrography allows reliable and accurate detection of SLAP lesions. In addition, SLAP lesions can be diagnosed and classified with substantial to excellent inter- and intraobserver agreement. (orig.)

  7. Hearing disorders in multiple sclerosis.

    Science.gov (United States)

    Furst, Miriam; Levine, Robert A

    2015-01-01

    Multiple sclerosis (MS) is a disease that is both a focal inflammatory and a chronic neurodegenerative disease. The focal inflammatory component is characterized by destruction of central nervous system myelin, including the spinal cord; as such it can impair any central neural system, including the auditory system. While on the one hand auditory complaints in MS patients are rare compared to other senses, such as vision and proprioception, on the other hand auditory tests of precise neural timing are never "silent." Whenever focal MS lesions are detected involving the pontine auditory pathway, auditory tests requiring precise neural timing are always abnormal, while auditory functions not requiring such precise timing are often normal. Azimuth sound localization is accomplished by comparing the timing and loudness of the sound at the two ears. Hence tests of azimuth sound localization must obligatorily involve the central nervous system and particularly the brainstem. Whenever a focal lesion was localized to the pontine auditory pathway, timing tests were always abnormal, but loudness tests were not. Moreover, a timing test that included only high-frequency sounds was very often abnormal, even when there was no detectable focal MS lesion involving the pontine auditory pathway. This test may be a marker for the chronic neurodegenerative aspect of MS, and, as such could be used to complement the magnetic resonance imaging scan in monitoring the neurodegenerative aspect of MS. Studies of MS brainstem lesion location and auditory function have led to advances in understanding how the human brain processes sound. The brain processes binaural sounds independently for time and level in a two-stage process. The first stage is at the level of the superior olivary complex (SOC) and the second at a level rostral to the SOC. © 2015 Elsevier B.V. All rights reserved.

  8. Tuberous sclerosis: diffusion MRI findings in the brain

    International Nuclear Information System (INIS)

    Sener, R.N.

    2002-01-01

    Diffusion MRI has mainly been used for detection of acute ischemia, and for distinction of cytotoxic and vasogenic edema. We applied diffusion MRI in patients with tuberous sclerosis in order to evaluate diffusion imaging characteristics of parenchymal changes. Five children with known tuberous sclerosis were included in this study. The MRI examinations were performed on a 1.5-T MR unit. Diffusion MRI was obtained using the echo-planar imaging sequence. Apparent diffusion coefficient (ADC) values from the abnormal brain parenchyma were calculated directly from automatically generated ADC maps. Seven normal children were available for comparison. In this control group the mean ADC value of the normal white matter was 0.84±0.12 x 10 -3 mm 2 /s. In tuberous sclerosis patients the mean ADC value of the white matter hamartomas (n=20) was apparently high (1.52±0.24 x 10 -3 mm 2 /s) compared with that of normal white matter. The ADC value of calcified hamartomas was ''zero''. The ADC value within a giant cell tumor was 0.89 x 10 -3 mm 2 /s, similar to that of normal cerebral white matter. The ADC maps were superior to b=1000 s/mm 2 (true diffusion) images with respect to lesion evaluation, and they provided mathematical information on tissue integrity. With respect to detection of the exact numbers and sizes of the parenchymal hamartomas fluid-attenuated inversion recovery images were superior to ADC maps. It is believed that diffusion MRI can be useful in evaluation of various parenchymal changes associated with tuberous sclerosis. Further studies on tuberous sclerosis, and on various brain lesions, would provide increasing data on this relatively new MRI sequence. (orig.)

  9. Wallerian degeneration of the corticodescending tract in the cerebral peduncle following a supratentorial cerebrovascular lesion detected by MRI

    International Nuclear Information System (INIS)

    Waragai, Masaaki; Iwabuchi, Sadamu

    1993-01-01

    We studied Wallerian degeneration of the corticodescending tract in the cerebral peduncle following a supratentorial cerebrovascular lesion by MRI. A total of 57 patients with palsy following a supratenotorial cerebrovascular lesion were prospectively studied. Wallerian degeneration was detected as a high signal intensity (HSI) in 37 patients between 70 days and 100 days after the onset, but not detected in the remaining 27 patients. Patient with as HSI in all areas of the cerebral peduncle had a large lesion involving the hemisphere. Patient with an HSI at the center of the cerebral peduncle had a lesion confined to the paracentral gyrus, precentral gyrus, corona radiata or posterior limb of the internal capsule. Patient with an HSI at the lateral side of the cerebral peduncle had a lesion of parietal lobe or temporal lobe which spares the corticospinal tract originating from the paracentral gyrus, precentral gyrus, corona radiata or posterior limb of the internal capsule. These findings suggest that as HSI at the center of the cerebral peduncle may reveal Wallerian degeneration of the corticospinal tract, and an HSI at the lateral side of the cerebral peduncle may show Wallerian degeneration of the corticopontine tract. The functional recovery of paresis was poor in all patients with an HSI at the center of the cerebral peduncle, while it was good in all patients without an HSI in that region. Our data suggested that somatotopical localization of the corticodescending tract in the cerebral peduncle may be identified by detecting Wallerian degeneration following a supratentorial lesion, and the functional recovery of patients with paresis could be predicted according to presence or absence of Wallerian degeneration at the center of the cerebral peduncle. (author)

  10. Unusual renal angiomyolipoma in tuberous sclerosis

    International Nuclear Information System (INIS)

    Schwartz, A.M.

    1980-01-01

    A patient with tuberous sclerosis and a normal intravenous urogram 5 years previously presented with a large and palpable upper pole renal mass. Since patients with tuberous sclerosis have small bilateral hamartomas, a Wilms' tumor was suspected. In retrospect, inhomogeneous nephrograms should have alerted the radiologist to the multiplicity of other small lesions. Also, a partially lucent rim should have substantiated that the lesion was not a Wilms' tumor. (orig.) [de

  11. Cavernous angioma associated with ipsilateral hippocampal sclerosis

    International Nuclear Information System (INIS)

    Okujava, M.; Ebner, A.; Schmitt, J.; Woermann, F.G.

    2002-01-01

    We report two cases with extratemporal cavernous angioma (CA) and coexisting ipsilateral hippocampal sclerosis. Classically dual pathology is defined as the association of hippocampal sclerosis with an extrahippocampal lesion. Subtle changes in hippocampus might be overlooked in the presence of an unequivocal extrahippocampal abnormality. Seizure outcome after epilepsy surgery in cases with dual pathology is less favourable if only one of the lesions is removed. Dual pathology must always be considered in diagnostic imaging of patients with intractable epilepsy and CA. (orig.)

  12. Cavernous angioma associated with ipsilateral hippocampal sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Okujava, M [Institute of Radiology and Interventional Diagnostics, Tbilisi (Georgia); Ebner, A; Schmitt, J; Woermann, F G [Bethel Epilepsy Centre, Mara Hospital, Bielefeld (Germany)

    2002-07-01

    We report two cases with extratemporal cavernous angioma (CA) and coexisting ipsilateral hippocampal sclerosis. Classically dual pathology is defined as the association of hippocampal sclerosis with an extrahippocampal lesion. Subtle changes in hippocampus might be overlooked in the presence of an unequivocal extrahippocampal abnormality. Seizure outcome after epilepsy surgery in cases with dual pathology is less favourable if only one of the lesions is removed. Dual pathology must always be considered in diagnostic imaging of patients with intractable epilepsy and CA. (orig.)

  13. Molecular detection of bacteria associated to caries activity in dentinal lesions.

    Science.gov (United States)

    Neves, Beatriz Gonçalves; Stipp, Rafael Nóbrega; da Silva Bezerra, Daniela; de Figueiredo Guedes, Sarah Florindo; Rodrigues, Lidiany Karla Azevedo

    2017-07-01

    This study aimed at identifying and quantifying Actinomyces naeslundii, Bifidobacterium spp., Streptococcus mitis group, Lactobacillus acidophilus, Lactobacillus casei group, Streptococcus gordonii, and Streptococcus mutans in active and inactive carious dentine lesions of children with early childhood caries by using quantitative polymerase chain reaction. Fifty-six dentin lesion samples, classified as active (n = 39) or inactive (n = 17), were collected from children aged from 2 to 5 years old. Dentinal-cavitated lesions were evaluated by Nyvad criteria for the assessment of caries lesion activity. Relative quantification revealed that Bifidobacterium spp. and the L. casei group were significantly more abundant in active dentin lesions (p oral microbiota related to dentin caries activity status is relevant, this study provides insights to better understand the differences in the microbiotas between active and arrested dentin cavities.

  14. Metastatic Breast Lesion to the Falx Detected with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Chester; Schuster, David M. [Emory Univ., Atlanta (United States)

    2012-06-15

    Intracranial dural metastasis is increasingly encountered in imaging. Autopsies conducted on patients with advanced metastatic disease demonstrate dural involvement in 9% of cases, with breast and prostate cancer the most common primaries. Awareness of this entity and imaging appearances is especially important in evaluating malignancies prone to dural metastasis. A 57-year-old woman with a strong family history of breast cancer initially presented after self-detection of a right breast lump. Subsequent mammogram and biopsies yielded a diagnosis of right infiltrating ductal carcinoma with a positive lymph node as well as left invasive lobular carcinoma. Initial staging PET-CT (not shown) at the time of diagnosis demonstrated no abnormal FDG uptake remote from the breast. Neoadjuvant chemotherapy was instituted, and a PET-CT was obtained to evaluate disease response, demonstrating an approximately 1.8 cm hypermetabolic intra-cranial mass, localized to the region of the anterior corpus callosum on axian PET (Fig. 1a), axial fused PET-CT (Fig. 1b), and sagittal fused PET-CT (Fig. 1c) with a maximum SUV of 15.9. There was associated bifrontal vasogenic edema (Fig. 1d) on the CT demonstrated on brain windows. Marked progression of disease was noted elsewhere, including hypermetabolic adenopathy and skeletal disease. A contrast-enhanced MRI of the brain was obtained demonstrating extensive T1 hypointensity, T2, and FLAIR (Fig. 2a) hyperintensity in the bilateral paramedian frontallobes representing vasogenic edema. Post-contrast imaging demonstrated three solidly enhancing masses in the areas of described vasogenic edema, one large extra-axial and two sub-centimeter parenchymal lesions. The large extra-axial and two sub-centimeter parenchymal lesions. The large extra-axial mass demonstrated homogeneous solid enhancement, in the midline anteriorly centered on the falx, just superior to the anterior corpus callosum. This measured 1.7cm transverse x 3.1cm AP x 2.4cm

  15. Can breast MRI computer-aided detection (CAD) improve radiologist accuracy for lesions detected at MRI screening and recommended for biopsy in a high-risk population?

    International Nuclear Information System (INIS)

    Arazi-Kleinman, T.; Causer, P.A.; Jong, R.A.; Hill, K.; Warner, E.

    2009-01-01

    Aim: To evaluate the sensitivity and specificity of magnetic resonance imaging (MRI) computer-aided detection (CAD) for breast MRI screen-detected lesions recommended for biopsy in a high-risk population. Material and methods: Fifty-six consecutive Breast Imaging Reporting and Data System (BI-RADS) 3-5 lesions with histopathological correlation [nine invasive cancers, 13 ductal carcinoma in situ (DCIS) and 34 benign] were retrospectively evaluated using a breast MRI CAD prototype (CAD-Gaea). CAD evaluation was performed separately and in consensus by two radiologists specializing in breast imaging, blinded to the histopathology. Thresholds of 50, 80, and 100% and delayed enhancement were independently assessed with CAD. Lesions were rated as malignant or benign according to threshold and delayed enhancement only and in combination. Sensitivities, specificities, and negative predictive values (NPV) were determined for CAD assessments versus pathology. Initial MRI BI-RADS interpretation without CAD versus CAD assessments were compared using paired binary diagnostic tests. Results: Threshold levels for lesion enhancement were: 50% to include all malignant (and all benign) lesions; and 100% for all invasive cancer and high-grade DCIS. Combined use of threshold and enhancement patterns for CAD assessment was best (73% sensitivity, 56% specificity and 76% NPV for all cancer). Sensitivities and NPV were better for invasive cancer (100%/100%) than for all malignancies (54%/76%). Radiologists' MRI interpretation was more sensitive than CAD (p = 0.05), but less specific (p = 0.001) for cancer detection. Conclusion: The breast MRI CAD system used could not improve the radiologists' accuracy for distinguishing all malignant from benign lesions, due to the poor sensitivity for DCIS detection.

  16. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging

    International Nuclear Information System (INIS)

    Gong Xing; Glick, Stephen J.; Liu, Bob; Vedula, Aruna A.; Thacker, Samta

    2006-01-01

    Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a three-dimensional (3D) object onto a 2D plane. Recently, two promising approaches for 3D volumetric breast imaging have been proposed, breast tomosynthesis (BT) and CT breast imaging (CTBI). To investigate possible improvements in lesion detection accuracy with either breast tomosynthesis or CT breast imaging as compared to digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through a CsI based flat-panel imager. Polyenergetic x-ray spectra of Mo/Mo 28 kVp for digital mammography, Mo/Rh 28 kVp for BT, and W/Ce 50 kVp for CTBI were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total average glandular dose of 4 mGy, which is approximately equivalent to that given in conventional two-view screening mammography. The same total dose was modeled for both the DM and BT simulations. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum, with the composition of 50% fibroglandular and 50% adipose tissue. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with five observers reading an ensemble of images for each case. The average area under the ROC curves (A z ) was 0.76 for DM, 0.93 for BT, and 0.94 for CTBI. Results indicated that for the same dose, a 5 mm lesion embedded in a structured breast phantom was detected by the two volumetric breast imaging systems, BT and CTBI, with statistically

  17. Rapid noninvasive detection of experimental atherosclerotic lesions with novel 99mTc-labeled diadenosine tetraphosphates

    Science.gov (United States)

    Elmaleh, David R.; Narula, Jagat; Babich, John W.; Petrov, Artiom; Fischman, Alan J.; Khaw, Ban-An; Rapaport, Eliezer; Zamecnik, Paul C.

    1998-01-01

    The development of a noninvasive imaging procedure for identifying atherosclerotic lesions is extremely important for the clinical management of patients with coronary artery and peripheral vascular disease. Although numerous radiopharmaceuticals have been proposed for this purpose, none has demonstrated the diagnostic accuracy required to replace invasive angiography. In this report, we used the radiolabeled purine analog, 99mTc diadenosine tetraphosphate (Ap4A; AppppA, P1,P4-di(adenosine-5′)-tetraphosphate) and its analogue 99mTc AppCHClppA for imaging experimental atherosclerotic lesions in New Zealand White rabbits. Serial gamma camera images were obtained after intravenous injection of the radiolabeled dinucleotides. After acquiring the final images, the animals were sacrificed, ex vivo images of the aortas were recorded, and biodistribution was measured. 99mTc-Ap4A and 99mTc AppCHClppA accumulated rapidly in atherosclerotic abdominal aorta, and lesions were clearly visible within 30 min after injection in all animals that were studied. Both radiopharmaceuticals were retained in the lesions for 3 hr, and the peak lesion to normal vessel ratio was 7.4 to 1. Neither of the purine analogs showed significant accumulation in the abdominal aorta of normal (control) rabbits. The excised aortas showed lesion patterns that were highly correlated with the in vivo and ex vivo imaging results. The present study demonstrates that purine receptors are up-regulated in experimental atherosclerotic lesions and 99mTc-labeled purine analogs have potential for rapid noninvasive detection of plaque formation. PMID:9435254

  18. Detection of cervical precancerous lesions with Aptima HPV assays using SurePath preservative fluid specimens

    Directory of Open Access Journals (Sweden)

    Max Chernesky

    2017-06-01

    Full Text Available SurePath specimens from women referred to colposcopy were treated with Aptima Transfer Solution (ATS before testing in Aptima HPV (AHPV and Aptima HPV 16, 18/45 (AHPV-GT assays. Untreated SurePath specimens were tested with the cobas HPV test. PreservCyt specimens were assessed for cytology and tested with AHPV. High-grade cervical intraepithelial neoplasia lesions served as the reference standard. Excellent agreement (95.5%; k=0.91 was observed for ATS-treated SurePath specimens between Tigris and Panther systems and between the PreservCyt and ATS-treated SurePath specimens (91.1%, k=0.81 with the AHPV assay on Tigris. Agreement between the AHPV and cobas assays with SurePath specimens was substantial (89.9%, k=0.80. AHPV sensitivity for CIN2+(n=147 was 91.2% for SurePath and PreservCyt. Cobas HPV sensitivity was 93.9% for SurePath specimens. AHPV testing of SurePath specimens was more specific (59.4% than cobas (54.7% (p<0.001. Detection and genotyping showed similar absolute and relative risks. ATS-treated SurePath specimens tested with AHPV and AHPV-GT assays showed similar performance with greater specificity than cobas HPV on SurePath specimens. Similar overall results were seen using a CIN3 disease endpoint. Keywords: Human papillomavirus, SurePath, PreservCyt, Cervical intraepithelial neoplasia, CIN2+, Aptima transfer solution (ATS

  19. Fusion of classifiers for REIS-based detection of suspicious breast lesions

    Science.gov (United States)

    Lederman, Dror; Wang, Xingwei; Zheng, Bin; Sumkin, Jules H.; Tublin, Mitchell; Gur, David

    2011-03-01

    After developing a multi-probe resonance-frequency electrical impedance spectroscopy (REIS) system aimed at detecting women with breast abnormalities that may indicate a developing breast cancer, we have been conducting a prospective clinical study to explore the feasibility of applying this REIS system to classify younger women (breast cancer. The system comprises one central probe placed in contact with the nipple, and six additional probes uniformly distributed along an outside circle to be placed in contact with six points on the outer breast skin surface. In this preliminary study, we selected an initial set of 174 examinations on participants that have completed REIS examinations and have clinical status verification. Among these, 66 examinations were recommended for biopsy due to findings of a highly suspicious breast lesion ("positives"), and 108 were determined as negative during imaging based procedures ("negatives"). A set of REIS-based features, extracted using a mirror-matched approach, was computed and fed into five machine learning classifiers. A genetic algorithm was used to select an optimal subset of features for each of the five classifiers. Three fusion rules, namely sum rule, weighted sum rule and weighted median rule, were used to combine the results of the classifiers. Performance evaluation was performed using a leave-one-case-out cross-validation method. The results indicated that REIS may provide a new technology to identify younger women with higher than average risk of having or developing breast cancer. Furthermore, it was shown that fusion rule, such as a weighted median fusion rule and a weighted sum fusion rule may improve performance as compared with the highest performing single classifier.

  20. An improved strategy for skin lesion detection and classification using uniform segmentation and feature selection based approach.

    Science.gov (United States)

    Nasir, Muhammad; Attique Khan, Muhammad; Sharif, Muhammad; Lali, Ikram Ullah; Saba, Tanzila; Iqbal, Tassawar

    2018-02-21

    Melanoma is the deadliest type of skin cancer with highest mortality rate. However, the annihilation in early stage implies a high survival rate therefore, it demands early diagnosis. The accustomed diagnosis methods are costly and cumbersome due to the involvement of experienced experts as well as the requirements for highly equipped environment. The recent advancements in computerized solutions for these diagnoses are highly promising with improved accuracy and efficiency. In this article, we proposed a method for the classification of melanoma and benign skin lesions. Our approach integrates preprocessing, lesion segmentation, features extraction, features selection, and classification. Preprocessing is executed in the context of hair removal by DullRazor, whereas lesion texture and color information are utilized to enhance the lesion contrast. In lesion segmentation, a hybrid technique has been implemented and results are fused using additive law of probability. Serial based method is applied subsequently that extracts and fuses the traits such as color, texture, and HOG (shape). The fused features are selected afterwards by implementing a novel Boltzman Entropy method. Finally, the selected features are classified by Support Vector Machine. The proposed method is evaluated on publically available data set PH2. Our approach has provided promising results of sensitivity 97.7%, specificity 96.7%, accuracy 97.5%, and F-score 97.5%, which are significantly better than the results of existing methods available on the same data set. The proposed method detects and classifies melanoma significantly good as compared to existing methods. © 2018 Wiley Periodicals, Inc.

  1. Skin lesion-associated pathogens from Octopus vulgaris: first detection of Photobacterium swingsii, Lactococcus garvieae and betanodavirus.

    Science.gov (United States)

    Fichi, G; Cardeti, G; Perrucci, S; Vanni, A; Cersini, A; Lenzi, C; De Wolf, T; Fronte, B; Guarducci, M; Susini, F

    2015-07-23

    The common octopus Octopus vulgaris Cuvier, 1798 is extremely important in fisheries and is a useful protein source in most Mediterranean countries. Here we investigated pathogens associated with skin lesions in 9 naturally deceased specimens that included both cultured and wild common octopus. Within 30 min after death, each octopus was stored at 4°C and microbiologically examined within 24 h. Bacterial colonies, cultured from swabs taken from the lesions, were examined using taxonomical and biochemical analyses. Vibrio alginolyticus and V. parahaemolyticus were only isolated from cultured animals. A conventional PCR targeting the 16S ribosomal RNA (rRNA) gene and sequencing were performed on 2 bacterial isolates that remained unidentified after taxonomical and biochemical analysis. The sequence results indicated that the bacteria had a 99% identity with Lactococcus garvieae and Photobacterium swingsii. L. garvieae was confirmed using a specific PCR based on the 16S-23S rRNA internal transcribed spacer region, while P. swingsii was confirmed by phylogenetic analyses. Although all animals examined were found to be infected by the protozoan species Aggregata octopiana localised in the intestines, it was also present in skin lesions of 2 of the animals. Betanodavirus was detected in both cultured and wild individuals by cell culture, PCR and electron microscopy. These findings are the first report of L. garvieae and betanodavirus from skin lesions of common octopus and the first identification of P. swingsii both in octopus skin lesions and in marine invertebrates in Italy.

  2. Clinical and MRI features in pediatric multiple sclerosis

    International Nuclear Information System (INIS)

    Zhao Cailei; Xie Sheng; Xiao Jiangxi; Wang Shuang

    2011-01-01

    Objective: To investigate the clinical and MRI features of multiple sclerosis in children, including the clinically isolated syndrome (CIS) and relapse. Methods: In total, 16 cases of pediatric multiple sclerosis were included in this study. Of them, 11 patients were female and 5 were male, with the mean onset age of 10.1 years. They were followed up for 4 months to 7 years and found to have 1- 5 relapses. The clinical manifestations of CIS and relapse were analyzed by a pediatric neurologist. An experienced neuroradiologist reviewed the MRI images of CIS and relapse. Information on the location, size, and pattern of the lesions was gathered. The location of lesions included subcortical, central, and periventricular white matter, cortex, deep gray matter, brain stem, and cerebellum. Results: CIS episode presented acute onsets in 13/16 cases, with symptoms of cortices in 10 cases and visual impairment in 6 cases. Relapse occurred in 14/16 cases within one year. The incidence of symptoms of cortices was less frequent and severe in the second episode of MS, whereas the visual impairment had a high incidence. All patients had full recovery after the last episode. MRI of CIS showed confluent subcortical white matter lesions in 13/16 cases, abutting on central white matter lesions. The most frequently involved brain part was the frontal lobe, followed by the parietal lobe. Cortical involvement was observed in 9/16 cases. In 6 cases, periventricular white matter lesions were detected. Bilateral deep gray matter was abnormal in 4 cases. Other abnormalities included brain stem lesions in 5 cases, cerebellum lesions in 3 cases, optic nerve involvement in 3 cases, and pyramidal tract lesions in 2 cases. MRI of relapse revealed more small lesions in the subcortical and periventricular white matter in the patients. In the second episode, only 2 cases presented cortical involvement. Lesions were found in the brain stem in 4 cases and in the cerebellum in 5 cases. Pyramidal tract

  3. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  4. Detection and repair of a UV-induced photosensitive lesion in the DNA of human cells

    International Nuclear Information System (INIS)

    Francis, A.A.; Regan, J.D.

    1986-01-01

    Irradiation with UV light results in damage to the DNA of human cells. The most numerous lesions are pyrimidine dimers; however, other lesions are known to occur and may contribute to the overall deleterious effect of UV irradiation. The authors have observed evidence of a UV-induced lesion other than pyrimidine dimers in the DNA of human cells by measuring DNA strand breaks induced by irradiating with 313-nm light following UV (254-nm) irradiation. The data suggest that, in normal cells, the lesion responsible for this effect is rapidly repaired or altered; whereas, in xeroderma pigmentosum variant cells it seems to remain unchanged. Some change apparently occurs in the DNA of xeroderma pigmentosum group A cells which results in an increase in photolability. These data indicate a deficiency in DNA repair of xeroderma pigmentosum variant cells as well as in xeroderma pigmentosum group A cells. (Auth.)

  5. Detection and Characterization of Focal Hepatic lesions using Magnetic resonance Imaging

    International Nuclear Information System (INIS)

    Pulgarin, Luis G; Delgado, Jorge Andres; Toro Nancy

    2008-01-01

    A retrospective one year study was performed from June 2006 to June 2007. A total of ten focal liver lesions in 60 patients were examined, describing their magnetic resonance (MR) characteristics, using T1, T2 and dynamic Gd-enhanced T1 weighted sequences with and without fat suppression. Lesions were classified into benign or malignant tumors and a diagnosis was proposed. Specific diagnoses such as simple cyst, abscess, hemangioma, focal nodular hyperplasia, hepatocellular carcinoma, and cholangiocarcinoma were reported.

  6. Postoperative quality of life outcome and employment in patients undergoing resection of epileptogenic lesions detected by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Akiyama, Yasuhiko; Nagai, Hidemasa; Maruyama, Nobuyuki; Takada, Daikei; Daisu, Mitsuhiro; Nagasako, Noriko; Mikuni, Nobuhiro; Hashimoto, Nobuo

    2009-01-01

    The long-term postoperative improvement of quality of life (QOL) and employment were investigated in patients undergoing resection of epileptogenic lesions detected by magnetic resonance (MR) imaging to identify the associated preoperative factors. Thirty of 47 patients who underwent lesionectomy between 1987-2001 replied to questionnaires. Patients with extratemporal resection outnumbered those with temporal lobe resection. The mean follow-up period was 12.4±3.7 years. An arbitrary score for quantitatively assessing QOL was assigned. The mean increases in QOL score points were significantly higher in the late childhood onset group than those in the early childhood onset group, and were also significantly higher in the temporal resection group and extratemporal resection of non-dysplastic cortical pathology group than in the extratemporal resection of dysplastic cortical pathology group. Postoperative QOL improvement and occupational status of patients depended on the completeness of seizure control. Resection of lesions detected by MR imaging in patients with intractable epilepsy resulted in effective long-term QOL improvement and postoperative occupational status. Favorable outcome was related mainly to the pathology of the epileptogenic lesions, whether the lesion site was temporal or extratemporal, and the completeness of seizure control. (author)

  7. Recurrent myelinoclastic diffuse sclerosis: a case report of a child with Schilder's variant of multiple sclerosis

    International Nuclear Information System (INIS)

    Fitzgerald, M.J.; Coleman, L.T.

    2000-01-01

    Myelinoclastic diffuse sclerosis (MDS, Schilder's disease) is a rare CNS demyelinating disorder affecting mainly children and usually presenting as an intracranial mass lesion. We report the first case of recurrent intracranial MDS where the third episode of demyelination involved the cervical spinal cord. This may represent a subset of the disease, which should be considered as Schilder's variant (childhood form) of multiple sclerosis. (orig.)

  8. "Blind spots" in forensic autopsy: improved detection of retrobulbar hemorrhage and orbital lesions by postmortem computed tomography (PMCT).

    Science.gov (United States)

    Flach, P M; Egli, T C; Bolliger, S A; Berger, N; Ampanozi, G; Thali, M J; Schweitzer, W

    2014-09-01

    The purpose of this study was to correlate the occurrence of retrobulbar hemorrhage (RBH) with mechanism of injury, external signs and autopsy findings to postmortem computed tomography (PMCT). Six-teen subjects presented with RBH and underwent PMCT, external inspection and conventional autopsy. External inspection was evaluated for findings of the bulbs, black eye, raccoon eyes and Battle's sign. Fractures of the viscerocranium, orbital lesions and RBH were evaluated by PMCT. Autopsy and PMCT was evaluated for orbital roof and basilar skull fracture. The leading manner of death was accident with central regulatory failure in cases of RBH (31.25%). Imaging showed a high sensitivity in detection of orbital roof and basilar skull fractures (100%), but was less specific compared to autopsy. Volume of RBH (0.1-2.4ml) correlated positively to the presence of Battle's sign (pautopsy. PMCT was superior in detecting osseous lesions, scrutinizing autopsy as the gold standard. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Nested PCR Assay for Detection of Leishmania donovani in Slit Aspirates from Post-Kala-Azar Dermal Leishmaniasis Lesions

    Science.gov (United States)

    Sreenivas, Gannavaram; Ansari, N. A.; Kataria, Joginder; Salotra, Poonam

    2004-01-01

    A nested PCR assay to detect parasite DNA in slit aspirates from skin lesions of patients with post-kala-azar dermal lesihmaniasis (PKDL) is described. PCR results were positive in 27 of 29 (93%) samples by nested PCR assay, while only 20 of 29 (69%) were positive in a primary PCR assay. The nested PCR assay allowed reliable diagnosis of PKDL in a noninvasive manner. PMID:15071047

  10. Nested PCR Assay for Detection of Leishmania donovani in Slit Aspirates from Post-Kala-Azar Dermal Leishmaniasis Lesions

    OpenAIRE

    Sreenivas, Gannavaram; Ansari, N. A.; Kataria, Joginder; Salotra, Poonam

    2004-01-01

    A nested PCR assay to detect parasite DNA in slit aspirates from skin lesions of patients with post-kala-azar dermal lesihmaniasis (PKDL) is described. PCR results were positive in 27 of 29 (93%) samples by nested PCR assay, while only 20 of 29 (69%) were positive in a primary PCR assay. The nested PCR assay allowed reliable diagnosis of PKDL in a noninvasive manner.

  11. Self-organizing neural networks for automatic detection and classification of contrast-enhancing lesions in dynamic MR-mammography

    International Nuclear Information System (INIS)

    Vomweg, T.W.; Teifke, A.; Kauczor, H.U.; Achenbach, T.; Rieker, O.; Schreiber, W.G.; Heitmann, K.R.; Beier, T.; Thelen, M.

    2005-01-01

    Purpose: Investigation and statistical evaluation of 'Self-Organizing Maps', a special type of neural networks in the field of artificial intelligence, classifying contrast enhancing lesions in dynamic MR-mammography. Material and Methods: 176 investigations with proven histology after core biopsy or operation were randomly divided into two groups. Several Self-Organizing Maps were trained by investigations of the first group to detect and classify contrast enhancing lesions in dynamic MR-mammography. Each single pixel's signal/time curve of all patients within the second group was analyzed by the Self-Organizing Maps. The likelihood of malignancy was visualized by color overlays on the MR-images. At last assessment of contrast-enhancing lesions by each different network was rated visually and evaluated statistically. Results: A well balanced neural network achieved a sensitivity of 90.5% and a specificity of 72.2% in predicting malignancy of 88 enhancing lesions. Detailed analysis of false-positive results revealed that every second fibroadenoma showed a 'typical malignant' signal/time curve without any chance to differentiate between fibroadenomas and malignant tissue regarding contrast enhancement alone; but this special group of lesions was represented by a well-defined area of the Self-Organizing Map. Discussion: Self-Organizing Maps are capable of classifying a dynamic signal/time curve as 'typical benign' or 'typical malignant'. Therefore, they can be used as second opinion. In view of the now known localization of fibroadenomas enhancing like malignant tumors at the Self-Organizing Map, these lesions could be passed to further analysis by additional post-processing elements (e.g., based on T2-weighted series or morphology analysis) in the future. (orig.)

  12. Evaluation of accuracy of intra operative imprint cytology for detection of breast lesions

    International Nuclear Information System (INIS)

    Mahmood, Z.; Shahbaz, A.; Qureshi, A.; Aziz, N.; Niazi, S.; Qureshi, S.; Bukhari, M.H.

    2010-01-01

    Objective: To determine the accuracy of imprint cytology as an intraoperative diagnostic procedure for breast lesions with histopathological correlation. Materials and Methods: This was a descriptive study on 40 cases of breast lesions comprising of inflammatory, benign and malignant lesions including their margins etc. It was conducted at King Edward Medical University, Lahore in collaboration with all Surgical Departments of Mayo Hospital. Relevant clinical data was recorded in a proforma. Both touch and scrape imprints were prepared from all the lesions and stained with May-Grunwaled Giemsa and Haematoxylin and Eosin stains. The imprints were subsequently compared with histopathology sections. Results: When we used atypical cases as negative both touch and scrape imprints gave sensitivity, specificity, positive predictive value, negative predictive value and accuracy at 100%. However when we used cases with atypia as positive, sensitivity and negative predictive value were 100% with both touch and scrape imprints. Specificity, positive predictive value and accuracy were 71%, 86%, 85.5% respectively with touch imprints and 78%, 89%, 89% respectively with scrape imprints. No diagnostic difference was noted between the results of both stains. All the imprints were well correlated with histopathological diagnosis. Conclusion: Imprint cytology is an accurate and simple intraoperative method for diagnosing breast lesions. It can provide the surgeons with information regarding immediate clinical and surgical interventions. (author)

  13. A comparison of lesion detection and conspicuity on T2-weighted images (T2 FFE), FLAIR and diffusion-weighted images in patients with traumatic brain injury

    International Nuclear Information System (INIS)

    Kwon, Eun Yong; Lee, Myeong sub; Kim, Myung Soon; Hong, In Soo; Kim, Young Ju; Whang, Gum

    2001-01-01

    To compare the lesion detectability and conspicuity in traumatic brain injury on T-2 FFE, FLAIR and diffusion weighted imaging (DWI) sequences. Thirty-three patients who underwent MR brain imaging after traumatic brain injury were reviewed. T-2 FFE, FLAIR and diffusion-weighted MR sequences were obtained and were compared in terms of the detectability and conspicuity of intra- and extra-axial lesions which showed abnormal signal intensities. Among 33 patients, a total of 108 lesions were found, T-2 FFE sequences detected 88(81%) of these, FLAIR sequences 91%(84%), and diffusion-weighted sequences 57(52%). In the case of petechial hemorrhagic lesions, 16 were detected by T-2 FFE imaging but only one by FLAIR and one by DWI. Sixteen extra-axial lesions (73%) were detected by T-2 FFE, 21 (95%) by FLAIR, and 11(50%) by DWI. Lesion conspicuity on FLAIR images was judged superior to that on T-2 FFE and diffusion-weighted images in 42 lesions (75%). Eleven extra-axial Lesions (92%) were more conspicuous on FLAIR than on T-2 FFE and DWI. For detecting traumatic brain lesions and determining their conspicuity, FLAIR imaging was more useful than T-2 FFE and diffusion weighting , while T-2 FFE imaging was more sensitive for the detecion of petechial hemorrhage. Although diffusion-weighted imaging was generally inferior to both FLAIR and T-2 FFE in terms of lesion detection and conspicuity, for some lesions it was superior. The results suggest that images obtained at each pulse sequence can be used as complementary imaging sequences, and that in traumatic brain injury, the acquisition of FLAIR, T-2 FFE and diffusion-weighted images is useful

  14. Automated Whole-Body Bone Lesion Detection for Multiple Myeloma on 68Ga-Pentixafor PET/CT Imaging Using Deep Learning Methods.

    Science.gov (United States)

    Xu, Lina; Tetteh, Giles; Lipkova, Jana; Zhao, Yu; Li, Hongwei; Christ, Patrick; Piraud, Marie; Buck, Andreas; Shi, Kuangyu; Menze, Bjoern H

    2018-01-01

    The identification of bone lesions is crucial in the diagnostic assessment of multiple myeloma (MM). 68 Ga-Pentixafor PET/CT can capture the abnormal molecular expression of CXCR-4 in addition to anatomical changes. However, whole-body detection of dozens of lesions on hybrid imaging is tedious and error prone. It is even more difficult to identify lesions with a large heterogeneity. This study employed deep learning methods to automatically combine characteristics of PET and CT for whole-body MM bone lesion detection in a 3D manner. Two convolutional neural networks (CNNs), V-Net and W-Net, were adopted to segment and detect the lesions. The feasibility of deep learning for lesion detection on 68 Ga-Pentixafor PET/CT was first verified on digital phantoms generated using realistic PET simulation methods. Then the proposed methods were evaluated on real 68 Ga-Pentixafor PET/CT scans of MM patients. The preliminary results showed that deep learning method can leverage multimodal information for spatial feature representation, and W-Net obtained the best result for segmentation and lesion detection. It also outperformed traditional machine learning methods such as random forest classifier (RF), k -Nearest Neighbors ( k -NN), and support vector machine (SVM). The proof-of-concept study encourages further development of deep learning approach for MM lesion detection in population study.

  15. Automated Whole-Body Bone Lesion Detection for Multiple Myeloma on 68Ga-Pentixafor PET/CT Imaging Using Deep Learning Methods

    Directory of Open Access Journals (Sweden)

    Lina Xu

    2018-01-01

    Full Text Available The identification of bone lesions is crucial in the diagnostic assessment of multiple myeloma (MM. 68Ga-Pentixafor PET/CT can capture the abnormal molecular expression of CXCR-4 in addition to anatomical changes. However, whole-body detection of dozens of lesions on hybrid imaging is tedious and error prone. It is even more difficult to identify lesions with a large heterogeneity. This study employed deep learning methods to automatically combine characteristics of PET and CT for whole-body MM bone lesion detection in a 3D manner. Two convolutional neural networks (CNNs, V-Net and W-Net, were adopted to segment and detect the lesions. The feasibility of deep learning for lesion detection on 68Ga-Pentixafor PET/CT was first verified on digital phantoms generated using realistic PET simulation methods. Then the proposed methods were evaluated on real 68Ga-Pentixafor PET/CT scans of MM patients. The preliminary results showed that deep learning method can leverage multimodal information for spatial feature representation, and W-Net obtained the best result for segmentation and lesion detection. It also outperformed traditional machine learning methods such as random forest classifier (RF, k-Nearest Neighbors (k-NN, and support vector machine (SVM. The proof-of-concept study encourages further development of deep learning approach for MM lesion detection in population study.

  16. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2015-10-01

    To assess the role of STIR, T2-weighted TSE and DWIBS sequences for detecting and characterizing breast lesions and to compare unenhanced (UE)-MRI results with contrast-enhanced (CE)-MRI and histological findings, having the latter as the reference standard. Two hundred eighty consecutive patients (age range, 27-73 years; mean age±standard deviation (SD), 48.8±9.8years) underwent MR examination with a diagnostic protocol including STIR, T2-weighted TSE, THRIVE and DWIBS sequences. Two radiologists blinded to both dynamic sequences and histological findings evaluated in consensus STIR, T2-weighted TSE and DWIBS sequences and after two weeks CE-MRI images searching for breast lesions. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and CE-MRI were calculated. UE-MRI results were also compared with CE- MRI. UE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 94%, 79%, 86%, 79% and 94%, respectively. CE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 98%, 83%, 90%, 84% and 98%, respectively. No statistically significant difference between UE-MRI and CE-MRI was found. Breast UE-MRI could represent an accurate diagnostic tool and a valid alternative to CE-MRI for evaluating breast lesions. STIR and DWIBS sequences allow to detect breast lesions while T2-weighted TSE sequences and ADC values could be useful for lesion characterization. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. MR in the diagnosis and monitoring of multiple sclerosis: An overview

    International Nuclear Information System (INIS)

    Rovira, Alex; Leon, Adelaida

    2008-01-01

    Multiple sclerosis is a chronic, persistent inflammatory-demyelinating disease of the central nervous system that typically presents as an acute clinically isolated syndrome attributable to a monofocal or multifocal demyelinating lesion, which usually affects the optic nerve, spinal cord, or brainstem and cerebellum. Although the diagnosis of multiple sclerosis is still based on clinical findings, magnetic resonance imaging is now integrated in the overall diagnostic scheme of the disease because of its unique sensitivity to demonstrate the spatial and temporal dissemination of demyelinating plaques in the brain and spinal cord. Conventional magnetic resonance imaging techniques, such as T2-weighted and gadolinium-enhanced T1-weighted sequences are highly sensitive in detecting multiple sclerosis plaques and provide a quantitative assessment of inflammatory activity and lesion load. However, there is a persisting mismatch between clinical and magnetic resonance imaging efficacy of approved treatments, which underlies the fact that this technique does not suffice to explain the entire spectrum of the disease process. In recent years, great effort has been dedicated to overcoming these limitations by using non-conventional magnetic resonance-derived metrics that can selectively measure the more destructive aspects of multiple sclerosis pathology and monitor the reparative mechanisms. These metrics, which include unenhanced T1-weighted imaging, measures of central nervous system atrophy, magnetization transfer imaging, proton magnetic resonance spectroscopy, diffusion-weighted imaging, and functional magnetic resonance imaging, provide a better approximation of the pathological substrate of the multiple sclerosis plaques, have increased our understanding of the pathogenesis of the disease, and have proven useful for studying the natural history of multiple sclerosis and monitoring the effects of new treatments. Therefore, magnetic resonance imaging not only plays an

  18. MR in the diagnosis and monitoring of multiple sclerosis: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, Alex [Magnetic Resonance Unit (I.D.I.), Department of Radiology, Hospital Universitari Vall d' Hebron, Barcelona (Spain)], E-mail: alex.rovira@idi-cat.org; Leon, Adelaida [Magnetic Resonance Unit (I.D.I.), Department of Radiology, Hospital Universitari Vall d' Hebron, Barcelona (Spain)

    2008-09-15

    Multiple sclerosis is a chronic, persistent inflammatory-demyelinating disease of the central nervous system that typically presents as an acute clinically isolated syndrome attributable to a monofocal or multifocal demyelinating lesion, which usually affects the optic nerve, spinal cord, or brainstem and cerebellum. Although the diagnosis of multiple sclerosis is still based on clinical findings, magnetic resonance imaging is now integrated in the overall diagnostic scheme of the disease because of its unique sensitivity to demonstrate the spatial and temporal dissemination of demyelinating plaques in the brain and spinal cord. Conventional magnetic resonance imaging techniques, such as T2-weighted and gadolinium-enhanced T1-weighted sequences are highly sensitive in detecting multiple sclerosis plaques and provide a quantitative assessment of inflammatory activity and lesion load. However, there is a persisting mismatch between clinical and magnetic resonance imaging efficacy of approved treatments, which underlies the fact that this technique does not suffice to explain the entire spectrum of the disease process. In recent years, great effort has been dedicated to overcoming these limitations by using non-conventional magnetic resonance-derived metrics that can selectively measure the more destructive aspects of multiple sclerosis pathology and monitor the reparative mechanisms. These metrics, which include unenhanced T1-weighted imaging, measures of central nervous system atrophy, magnetization transfer imaging, proton magnetic resonance spectroscopy, diffusion-weighted imaging, and functional magnetic resonance imaging, provide a better approximation of the pathological substrate of the multiple sclerosis plaques, have increased our understanding of the pathogenesis of the disease, and have proven useful for studying the natural history of multiple sclerosis and monitoring the effects of new treatments. Therefore, magnetic resonance imaging not only plays an

  19. Effect of glatiramer acetate on conversion to clinically definite multiple sclerosis in patients with clinically isolated syndrome (PreCISe study): a randomised, double-blind, placebo-controlled trial

    DEFF Research Database (Denmark)

    Comi, G; Martinelli, V; Rodegher, M

    2009-01-01

    BACKGROUND: Glatiramer acetate, approved for the treatment of relapsing-remitting multiple sclerosis, reduces relapses and disease activity and burden monitored by MRI. We assessed the efficacy of early treatment with glatiramer acetate in delaying onset of clinically definite multiple sclerosis....... treatment with glatiramer acetate is efficacious in delaying conversion to clinically definite multiple sclerosis in patients presenting with clinically isolated syndrome and brain lesions detected by MRI. FUNDING: Teva Pharmaceutical Industries, Israel.......BACKGROUND: Glatiramer acetate, approved for the treatment of relapsing-remitting multiple sclerosis, reduces relapses and disease activity and burden monitored by MRI. We assessed the efficacy of early treatment with glatiramer acetate in delaying onset of clinically definite multiple sclerosis...

  20. Accuracy of the double contrast technique in the detection of small lesions of the colon

    Energy Technology Data Exchange (ETDEWEB)

    Muzzio, P C; Pomerri, F; Feltrin, G P; Biondetti, P R; Di Maggio, C [Padua Univ. (Italy). Istituto di Radiologia e Fisioterapia

    1979-02-01

    Double contrast enema has become an indispensible aid in early lesions of the colon, in particular for small lesions. According to the authors' opinion, the method provides so much additional information that it ought to be applied at all rates in such cases. It is neither expensive nor time-consuming and can easily be carried out in any X-ray department, especially where a fibroscope is not available. The results are reliable if the technique is applied correctly, if the patient is well-prepared, and if the radiologist has enough technical and semiological experience.

  1. Early Magnetic Resonance Detection of Natalizumab-Related Progressive Multifocal Leukoencephalopathy in a Patient with Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Guglielmo Manenti

    2013-01-01

    Full Text Available Diagnosis of progressive multifocal leukoencephalopathy is usually based on the clinical presentation, on the demonstration of the brain lesions at the magnetic resonance imaging examination, and on the detection of the JC virus DNA in the cerebrospinal fluid with high sensitive polymerase chain reaction. The role of magnetic resonance imaging specifically in natalizumab-associated progressive multifocal leukoencephalopathy is strengthening, and it is gaining importance not only as an irreplaceable diagnostic tool but also as a surveillance and risk stratifying tool in treated patients. While other imaging techniques such as computed tomography lack sensitivity and specificity, magnetic resonance performed with morphological and functional sequences offers clinicians the possibility to early identify the stage of the disease and the emergence of an immune reconstitution inflammatory syndrome after natalizumab blood removal plasmapheresis.

  2. Detection of retinal lesions in diabetic retinopathy: comparative evaluation of 7-field digital color photography versus red-free photography.

    Science.gov (United States)

    Venkatesh, Pradeep; Sharma, Reetika; Vashist, Nagender; Vohra, Rajpal; Garg, Satpal

    2015-10-01

    Red-free light allows better detection of vascular lesions as this wavelength is absorbed by hemoglobin; however, the current gold standard for the detection and grading of diabetic retinopathy remains 7-field color fundus photography. The goal of this study was to compare the ability of 7-field fundus photography using red-free light to detect retinopathy lesions with corresponding images captured using standard 7-field color photography. Non-stereoscopic standard 7-field 30° digital color fundus photography and 7-field 30° digital red-free fundus photography were performed in 200 eyes of 103 patients with various grades of diabetic retinopathy ranging from mild to moderate non-proliferative diabetic retinopathy to proliferative diabetic retinopathy. The color images (n = 1,400) were studied with corresponding red-free images (n = 1,400) by one retina consultant (PV) and two senior residents training in retina. The various retinal lesions [microaneurysms, hemorrhages, hard exudates, soft exudates, intra-retinal microvascular anomalies (IRMA), neovascularization of the retina elsewhere (NVE), and neovascularization of the disc (NVD)] detected by all three observers in each of the photographs were noted followed by determination of agreement scores using κ values (range 0-1). Kappa coefficient was categorized as poor (≤0), slight (0.01-0.20), fair (0.2 -0.40), moderate (0.41-0.60), substantial (0.61-0.80), and almost perfect (0.81-1). The number of lesions detected by red-free images alone was higher for all observers and all abnormalities except hard exudates. Detection of IRMA was especially higher for all observers with red-free images. Between image pairs, there was substantial agreement for detection of hard exudates (average κ = 0.62, range 0.60-0.65) and moderate agreement for detection of hemorrhages (average κ = 0.52, range 0.45-0.58), soft exudates (average κ = 0.51, range 0.42-0.61), NVE (average κ = 0.47, range 0.39-0.53), and NVD

  3. Bipedal hopping timed to a metronome to detect impairments in anticipatory motor control in people with mild multiple sclerosis.

    Science.gov (United States)

    Kirkland, Megan C; Chen, Alice; Downer, Matthew B; Holloway, Brett J; Wallack, Elizabeth M; Lockyer, Evan J; Buckle, Natasha C M; Abbott, Courtney L; Ploughman, Michelle

    2018-06-01

    People with mild multiple sclerosis (MS) often report subtle deficits in balance and cognition but display no measurable impairment on clinical assessments. We examined whether hopping to a metronome beat had the potential to detect anticipatory motor control deficits among people with mild MS (Expanded Disability Status Scale ≤ 3.5). Participants with MS (n = 13), matched controls (n = 9), and elderly subjects (n = 13) completed tests of cognition (Montreal Cognitive Assessment (MoCA)) and motor performance (Timed 25 Foot Walk Test (T25FWT)). Participants performed two bipedal hopping tasks: at 40 beats/min (bpm) and 60-bpm in random order. Hop characteristics (length, symmetry, variability) and delay from the metronome beat were extracted from an instrumented walkway and compared between groups. The MS group became more delayed from the metronome beat over time whereas elderly subjects tended to hop closer to the beat (F = 4.52, p = 0.02). Delay of the first hop during 60-bpm predicted cognition in people with MS (R = 0.55, β = 4.64 (SD 4.63), F = 4.85, p = 0.05) but not among control (R = 0.07, p = 0.86) or elderly subjects (R = 0.17, p = 0.57). In terms of hopping characteristics, at 60-bpm, people with MS and matched controls were significantly different from the elderly group. However, at 40-bpm, the MS group was no longer significantly different from the elderly group, even though matched controls and elderly still differed significantly. This new timed hopping test may be able to detect both physical ability, and feed-forward anticipatory control impairments in people with mild MS. Hopping at a frequency of 40-bpm seemed more challenging. Several aspects of anticipatory motor control can be measured: including reaction time to the first metronome cue and the ability to adapt and anticipate the beat over time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  4. Topographic distribution of brain iron deposition and small cerebrovascular lesions in amyotrophic lateral sclerosis and in frontotemporal lobar degeneration: a post-mortem 7.0-tesla magnetic resonance imaging study with neuropathological correlates.

    Science.gov (United States)

    De Reuck, Jacques; Devos, David; Moreau, Caroline; Auger, Florent; Durieux, Nicolas; Deramecourt, Vincent; Pasquier, Florence; Maurage, Claude-Alain; Cordonnier, Charlotte; Leys, Didier; Bordet, Regis

    2017-12-01

    Amyotrophic lateral sclerosis (ALS) is associated with frontotemporal lobar degeneration (FTLD) in 15% of the cases. A neuropathological continuity between ALS and FTLD-TDP is suspected. The present post-mortem 7.0-tesla magnetic resonance imaging (MRI) study compares the topographic distribution of iron (Fe) deposition and the incidence of small cerebrovascular lesions in ALS and in FTLD brains. Seventy-eight post-mortem brains underwent 7.0-tesla MRI. The patients consisted of 12 with ALS, 38 with FTLD, and 28 controls. Three ALS brains had minor FTLD features. Three coronal sections of a cerebral hemisphere were submitted to T2 and T2* MRI sequences. The amount of Fe deposition in the deep brain structures and the number of small cerebrovascular lesions was determined in ALS and the subtypes of FTLD compared to control brains, with neuropathological correlates. A significant increase of Fe deposition was observed in the claustrum, caudate nucleus, globus pallidus, thalamus, and subthalamic nucleus of the FTLD-FUS and FTLD-TDP groups, while in the ALS one, the Fe increase was only observed in the caudate and the subthalamic nuclei. White matter changes were only significantly more severe in the FTLD compared to those in ALS and in controls brains. Cortical micro-bleeds were increased in the frontal and temporal lobes of FTLD as well as of ALS brains compared to controls. Cortical micro-infarcts were, on the other hand, more frequent in the control compared to the ALS and FTLD groups. The present study supports the assumption of a neuropathological continuity between ALS and FTLD and illustrates the favourable vascular risk profile in these diseases.

  5. Detection of white spot lesions by segmenting laser speckle images using computer vision methods.

    Science.gov (United States)

    Gavinho, Luciano G; Araujo, Sidnei A; Bussadori, Sandra K; Silva, João V P; Deana, Alessandro M

    2018-05-05

    This paper aims to develop a method for laser speckle image segmentation of tooth surfaces for diagnosis of early stages caries. The method, applied directly to a raw image obtained by digital photography, is based on the difference between the speckle pattern of a carious lesion tooth surface area and that of a sound area. Each image is divided into blocks which are identified in a working matrix by their χ 2 distance between block histograms of the analyzed image and the reference histograms previously obtained by K-means from healthy (h_Sound) and lesioned (h_Decay) areas, separately. If the χ 2 distance between a block histogram and h_Sound is greater than the distance to h_Decay, this block is marked as decayed. The experiments showed that the method can provide effective segmentation for initial lesions. We used 64 images to test the algorithm and we achieved 100% accuracy in segmentation. Differences between the speckle pattern of a sound tooth surface region and a carious region, even in the early stage, can be evidenced by the χ 2 distance between histograms. This method proves to be more effective for segmenting the laser speckle image, which enhances the contrast between sound and lesioned tissues. The results were obtained with low computational cost. The method has the potential for early diagnosis in a clinical environment, through the development of low-cost portable equipment.

  6. Detection of optic nerve lesions in optic neuritis using frequency-selective fat-saturation sequences

    International Nuclear Information System (INIS)

    Miller, D.H.; MacManus, D.G.; Bartlett, P.A.; Kapoor, R.; Morrissey, S.P.; Moseley, I.F.

    1993-01-01

    MRI was performed on seven patients with acute optic neuritis, using two sequences which suppress the signal from orbital fat: frequency-selective fat-saturation and inversion recovery with a short inversion time. Lesions were seen on both sequences in all the symptomatic optic nerves studied. (orig.)

  7. Three dimensional quantitative coronary angiography can detect reliably ischemic coronary lesions based on fractional flow reserve.

    Science.gov (United States)

    Chung, Woo-Young; Choi, Byoung-Joo; Lim, Seong-Hoon; Matsuo, Yoshiki; Lennon, Ryan J; Gulati, Rajiv; Sandhu, Gurpreet S; Holmes, David R; Rihal, Charanjit S; Lerman, Amir

    2015-06-01

    Conventional coronary angiography (CAG) has limitations in evaluating lesions producing ischemia. Three dimensional quantitative coronary angiography (3D-QCA) shows reconstructed images of CAG using computer based algorithm, the Cardio-op B system (Paieon Medical, Rosh Ha'ayin, Israel). The aim of this study was to evaluate whether 3D-QCA can reliably predict ischemia assessed by myocardial fractional flow reserve (FFR) < 0.80. 3D-QCA images were reconstructed from CAG which also were evaluated with FFR to assess ischemia. Minimal luminal diameter (MLD), percent diameter stenosis (%DS), minimal luminal area (MLA), and percent area stenosis (%AS) were obtained. The results of 3D-QCA and FFR were compared. A total of 266 patients was enrolled for the present study. FFR for all lesions ranged from 0.57 to 1.00 (0.85 ± 0.09). Measurement of MLD, %DS, MLA, and %AS all were significantly correlated with FFR (r = 0.569, 0609, 0.569, 0.670, respectively, all P < 0.001). In lesions with MLA < 4.0 mm(2), %AS of more than 65.5% had a 80% sensitivity and a 83% specificity to predict FFR < 0.80 (area under curve, AUC was 0.878). 3D-QCA can reliably predict coronary lesions producing ischemia and may be used to guide therapeutic approach for coronary artery disease.

  8. Contrast enhanced digital mammography: Is it useful in detecting lesions in edematous breast?

    Directory of Open Access Journals (Sweden)

    Noha Abd ElShafy ElSaid

    2015-09-01

    Conclusion: Dual-energy contrast-enhanced digital mammography is a useful technique in identification of lesions in mammographically dense edematous breasts and proved to be a useful tool in the follow-up of cases presenting by edema after conservative breast surgery and chemotherapy.

  9. Detecting ICRS grade 1 cartilage lesions in anterior cruciate ligament injury using T1ρ and T2 mapping

    Energy Technology Data Exchange (ETDEWEB)

    Nishioka, Hiroaki, E-mail: kinuhnishiok@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Hirose, Jun, E-mail: hirojun-mk@umin.ac.jp [Department of Orthopaedic Surgery, Kumamoto University Hospital, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Nakamura, Eiichi, E-mail: h@kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Okamoto, Nobukazu, E-mail: nobuoka9999@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Karasugi, Tatsuki, E-mail: tatsukik@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Taniwaki, Takuya, E-mail: takuyataniwaki@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Okada, Tatsuya, E-mail: tatsuya-okada@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Yamashita, Yasuyuki, E-mail: yama@kumamoto-u.ac.jp [Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Mizuta, Hiroshi, E-mail: mizuta@kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan)

    2013-09-15

    Objective: The purpose of this study was to clarify the detectability of the International Cartilage Repair Society (ICRS) grade 1 cartilage lesions in anterior cruciate ligament (ACL)–injured knees using T1ρ and T2 mapping. Materials and Methods: We performed preoperative T1ρ and T2 mapping and 3D gradient–echo with water–selective excitation (WATS) sequences on 37 subjects with ACL injuries. We determined the detectability on 3D WATS based on arthroscopic findings. The T1ρ and T2 values (ms) were measured in the regions of interest that were placed on the weight–bearing cartilage of the femoral condyle. The receiver operating characteristic (ROC) curve based on these values was constructed using the arthroscopic findings as a reference standard. The evaluation of cartilage was carried out only in the weight–bearing cartilage. The cut–off values for determining the presence of a cartilage injury were determined using each ROC curve, and the detectability was calculated for the T1ρ and T2 mapping. Results: The cut–off values for the T1ρ and T2 were 41.6 and 41.2, respectively. The sensitivity and specificity of T1ρ were 91.2% and 89.5%, respectively, while those of T2 were 76.5% and 81.6%, respectively. For the 3D WATS images, the same values were 58.8% and 78.9%, respectively. Conclusions: Our study demonstrated that the T1ρ and T2 values were significantly higher for ICRS grade 1 cartilage lesions than for normal cartilage and that the two mappings were able to non–invasively detect ICRS grade 1 cartilage lesions in the ACL–injured knee with a higher detectability than were 3D WATS images.

  10. PET/CT detectability and classification of simulated pulmonary lesions using an SUV correction scheme

    Science.gov (United States)

    Morrow, Andrew N.; Matthews, Kenneth L., II; Bujenovic, Steven

    2008-03-01

    Positron emission tomography (PET) and computed tomography (CT) together are a powerful diagnostic tool, but imperfect image quality allows false positive and false negative diagnoses to be made by any observer despite experience and training. This work investigates PET acquisition mode, reconstruction method and a standard uptake value (SUV) correction scheme on the classification of lesions as benign or malignant in PET/CT images, in an anthropomorphic phantom. The scheme accounts for partial volume effect (PVE) and PET resolution. The observer draws a region of interest (ROI) around the lesion using the CT dataset. A simulated homogenous PET lesion of the same shape as the drawn ROI is blurred with the point spread function (PSF) of the PET scanner to estimate the PVE, providing a scaling factor to produce a corrected SUV. Computer simulations showed that the accuracy of the corrected PET values depends on variations in the CT-drawn boundary and the position of the lesion with respect to the PET image matrix, especially for smaller lesions. Correction accuracy was affected slightly by mismatch of the simulation PSF and the actual scanner PSF. The receiver operating characteristic (ROC) study resulted in several observations. Using observer drawn ROIs, scaled tumor-background ratios (TBRs) more accurately represented actual TBRs than unscaled TBRs. For the PET images, 3D OSEM outperformed 2D OSEM, 3D OSEM outperformed 3D FBP, and 2D OSEM outperformed 2D FBP. The correction scheme significantly increased sensitivity and slightly increased accuracy for all acquisition and reconstruction modes at the cost of a small decrease in specificity.

  11. Antigen-specific therapies in multiple sclerosis

    NARCIS (Netherlands)

    Noort, J.M. van

    1998-01-01

    Multiple sclerosis is the major neurological disease of young adults in the western world, affecting about 1 per 1,000. It is characterised by chronic or recurrent lesions of inflammatory damage in the white matter of the central nervous system. Within such lesions, the protective myelin sheath is

  12. Association between power law coefficients of the anatomical noise power spectrum and lesion detectability in breast imaging modalities

    Science.gov (United States)

    Chen, Lin; Abbey, Craig K.; Boone, John M.

    2013-03-01

    Previous research has demonstrated that a parameter extracted from a power function fit to the anatomical noise power spectrum, β, may be predictive of breast mass lesion detectability in x-ray based medical images of the breast. In this investigation, the value of β was compared with a number of other more widely used parameters, in order to determine the relationship between β and these other parameters. This study made use of breast CT data sets, acquired on two breast CT systems developed in our laboratory. A total of 185 breast data sets in 183 women were used, and only the unaffected breast was used (where no lesion was suspected). The anatomical noise power spectrum computed from two-dimensional region of interests (ROIs), was fit to a power function (NPS(f) = α f-β), and the exponent parameter (β) was determined using log/log linear regression. Breast density for each of the volume data sets was characterized in previous work. The breast CT data sets analyzed in this study were part of a previous study which evaluated the receiver operating characteristic (ROC) curve performance using simulated spherical lesions and a pre-whitened matched filter computer observer. This ROC information was used to compute the detectability index as well as the sensitivity at 95% specificity. The fractal dimension was computed from the same ROIs which were used for the assessment of β. The value of β was compared to breast density, detectability index, sensitivity, and fractal dimension, and the slope of these relationships was investigated to assess statistical significance from zero slope. A statistically significant non-zero slope was considered to be a positive association in this investigation. All comparisons between β and breast density, detectability index, sensitivity at 95% specificity, and fractal dimension demonstrated statistically significant association with p performance. Specifically, lower values of β were associated with lower breast density

  13. Detection of occlusal caries lesions using fluorescence: correlation between histology and obtained results for Diagnodent and spectroscopy

    International Nuclear Information System (INIS)

    Rocha-Cabral, Renata Maciel

    2006-01-01

    The aims of this study were to develop and test a method to detect caries lesions in vivo and in vitro, using a portable spectrometer (PS); to analyze the performance of PS as well as the commercial device Diagnodent (Dd); correlate them with the gold standard, their transversal section areas and lesions depth and between themselves. 66 occlusal pre-molars sites were examined in vivo with Dd. Sequentially, fluorescence (λexc ∼ 657 nm) was collected by an optical fiber, conducted to PS and then analyzed as spectra, which were normalized and had calculated the Ratios of their Areas Under the Curves (RAUC) of carious and sound tissues. Experiments were conducted in vitro in the same sites. Gold Standard was obtained by polarized light microscopy. Pearson correlation was used to compare the devices with transversal section area, lesions depth and between themselves. The area under ROC curve, sensitivity, specificity as well as accuracy were calculated and verified with McNemar test. Dd and RAUC showed statistically significant correlation with gold standard (p < 0.01 for Dd and p < 0.05 for RAUC) and between themselves (r = 0,83 in vivo and r = 0,87 in vitro). Although it was significant, the devices showed low correlation with depth of lesions in vivo and in vitro (r = ∼ 0.43). The transversal section area of the lesion had no influence on readings in both devices. Dd showed higher sensitivity (0.76) than PS (0.60) in vivo (p < 0.05), though this fact was not able to improve its performance. In turn, PS showed higher sensitivity (0.88) than Dd (0.79) in vitro, but this difference was not significantly. The other parameters did not show statistically significant differences (p < 0.05) between methods. PS showed positive correlation with Dd, equal correlation with lesions depth and higher ability of detecting the disease in vitro, what suggests that if accompanied with a conic and an angulated probe and a dedicated software, the PS method could be useful in clinics

  14. Cognitive deficits in multiple sclerosis

    DEFF Research Database (Denmark)

    Lund, H; Jønsson, A; Andresen, Jesper Graubæk

    2012-01-01

    of the cognitive impairment seen in MS and constitute a supplement to traditional measurement of T2 lesion volume. Materials and Methods - Fifty patients with clinically definite MS were included (38 women, 12 men). Patients were MR scanned, neuropsychologically tested, and evaluated clinically with the Kurtzke......Objectives - Although disease load in multiple sclerosis (MS) often is based on T2 lesion volumes, the changes in T2 of normal appearing brain tissue (NABT) are rarely considered. By means of magnetic resonance, (MR) we retrospectively investigated whether T2 changes in NABT explain part...... Expanded Disability Status Scale (EDSS) and the Multiple Sclerosis Impairment Scale (MSIS). Voxel-wise T2 estimates and total T2 lesion volume were tested for correlations with eight cognitive domains, a general cognitive dysfunction factor (CDF), and the two clinical scales. Results - We found distinct...

  15. Multiple Sclerosis

    Science.gov (United States)

    Multiple sclerosis (MS) is a nervous system disease that affects your brain and spinal cord. It damages the myelin sheath, the material that surrounds and protects your nerve cells. This damage slows down ...

  16. Tuberous Sclerosis

    Science.gov (United States)

    ... National Institute of Neurological Disorders and Stroke (NINDS). Esclerosis tuberosa Order NINDS Publications Patient Organizations Child Neurology ... National Institute of Neurological Disorders and Stroke (NINDS). Esclerosis tuberosa Order NINDS Publications Definition Tuberous sclerosis (TSC) ...

  17. Globular domain of adiponectin: promising target molecule for detection of atherosclerotic lesions

    Science.gov (United States)

    Almer, Gunter; Saba-Lepek, Matthias; Haj-Yahya, Samih; Rohde, Eva; Strunk, Dirk; Fröhlich, Eleonore; Prassl, Ruth; Mangge, Harald

    2011-01-01

    Background: Adiponectin, an adipocyte-specific plasma protein, has been shown to accumulate in injured endothelial cells during development of atherosclerotic lesions. In this study, we investigated the potential of different adiponectin subfractions with special emphasis on globular adiponectin (gAd) to recognize and visualize atherosclerotic lesions. Methods: Recombinant mouse gAd and subfractions of full-length adiponectin (ie, trimeric, hexameric, and oligomeric forms) were fluorescence-labeled. Aortas of wild-type and apoprotein E-deficient mice fed a high cholesterol diet were dissected and incubated with the labeled biomarkers. Imaging was performed using confocal laser scanning microscopy. Results: Confocal laser scanning microscopic images showed that gAd binds more strongly to atherosclerotic plaques than full-length adiponectin subfractions. Further, we showed that gAd accumulates preferentially in endothelial cells and the fibrous cap area of plaques. Here we demonstrate for the first time that gAd recognizes atherosclerotic plaques on aortic sections of apoprotein E-deficient mice. Conclusion: These results suggest that gAd, in addition to its physiological properties, is also suitable as a target molecule for prospective diagnostic strategies in imaging atherosclerotic lesions. PMID:22022204

  18. Computer-aided detection (CAD) and assessment of malignant lesions in the liver and lung using a novel PET/CT software tool. Initial results

    International Nuclear Information System (INIS)

    Hahn, Steffen; Heusner, T.; Forsting, M.; Antoch, G.; Zhou, X.; Zhan, Y.; Peng, Z.; Hamami, M.; Bockisch, A.

    2010-01-01

    Purpose: To determine the feasibility of a PET/CT software tool (PET computer-aided detection: PET-CAD) for automated detection and assessment of pulmonary and hepatic lesions. Materials and Methods: 20 consecutive patients with colorectal liver metastases and 20 consecutive patients suffering from non-small cell lung cancer (NSCLC) were examined with FDG-PET/CT. In a first step the maximum standardized uptake values (SUV max ) of non-tumorous liver and lung tissues were determined manually. This value was used as a threshold value for software-based lesion detection. The number of lesions detected, their SUV max , and their sizes in the x, y, and z-planes, as automatically provided by PET-CAD, were compared to visual lesion detection and manual measurements on CT. Results: The sensitivity for automated detection was 96% (86-99%) for colorectal liver metastases and 90% (70-99%) for lung lesions. The positive predictive value was 80% for liver and 68% for lung lesions. The mean SUV max of all lung lesions was 9.3 and 8.8 for the liver lesions. When assessed by PET-CAD, the mean lesion sizes for liver lesions in the x, y, and z-planes were 4.3 cm, 4.6 cm, and 4.2 cm compared to 3.5 cm, 3.8 cm, and 3.6 cm for manual measurements. The mean lesion sizes of lung lesions were 7.4 cm, 7.7 cm, and 8.4 cm in the x, y, and z-planes when assessed by PET-CAD compared to 5.8 cm, 6.1 cm, and 7.1 cm when measured manually. Using manual assessment, the lesion sizes were significantly smaller in all planes (p < 0.005). Conclusion: Software tools for automated lesion detection and assessment are expected to improve the clinical PET/CT workflow. Before implementation in the clinical routine, further improvements to the measurement accuracy are required. (orig.)

  19. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias [University Hospital Bonn, Department of Radiology, Bonn (Germany); Gieseke, Juergen [Philips Healthcare Germany, Hamburg (Germany); Willinek, Winfried [Hospital of Barmherzige Brueder, Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Trier (Germany)

    2018-01-15

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  20. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias; Gieseke, Juergen; Willinek, Winfried

    2018-01-01

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  1. Influence of attenuation correction and reconstruction techniques on the detection of hypoperfused lesions in brain SPECT studies

    International Nuclear Information System (INIS)

    Ghoorun, S.; Groenewald, W.A.; Baete, K.; Nuyts, J.; Dupont, P.

    2004-01-01

    Full text: Aim: To study the influence of attenuation correction and the reconstruction technique on the detection of hypoperfused lesions in brain SPECT imaging, Material and Methods: A simulation experiment was used in which the effects of attenuation and reconstruction were decoupled, A high resolution SPECT phantom was constructed using the BrainWeb database, In this phantom, activity values were assigned to grey and white matter (ratio 4:1) and scaled to obtain counts of the same magnitude as in clinical practice, The true attenuation map was generated by assigning attenuation coefficients to each tissue class (grey and white matter, cerebral spinal fluid, skull, soft and fatty tissue and air) to create a non-uniform attenuation map, The uniform attenuation map was calculated using an attenuation coefficient of 0.15 cm-1, Hypoperfused lesions of varying intensities and sizes were added. The phantom was then projected as typical SPECT projection data, taking into account attenuation and collimator blurring with the addition of Poisson noise, The projection data was reconstructed using four different methods of reconstruction: (1) filtered backprojection (FBP) with the uniform attenuation map; (2) FBP using the true attenuation map; (3) ordered subset expectation maximization (OSEM) (equivalent to 423 iterations) with a uniform attenuation map; and (4) OSEM with a true attenuation map. Different Gaussian postsmooth kernels were applied to the reconstructed images. Results: The analysis of the reconstructed data was performed using figures of merit such as signal to noise ratio (SNR), bias and variance. The results illustrated that uniform attenuation correction offered slight deterioration (less than 2%) with regard to SNR when compared to the ideal attenuation map. which in reality is not known. The iterative techniques produced superior signal to noise ratios (increase of 5 - 20 % depending on the lesion and the postsmooth) in comparison to the FBP methods

  2. The Problems with the Kappa Statistic as a Metric of Interobserver Agreement on Lesion Detection Using a Third-reader Approach When Locations Are Not Prespecified.

    Science.gov (United States)

    Shih, Joanna H; Greer, Matthew D; Turkbey, Baris

    2018-03-16

    To point out the problems with Cohen kappa statistic and to explore alternative metrics to determine interobserver agreement on lesion detection when locations are not prespecified. Use of kappa and two alternative methods, namely index of specific agreement (ISA) and modified kappa, for measuring interobserver agreement on the location of detected lesions are presented. These indices of agreement are illustrated by application to a retrospective multireader study in which nine readers detected and scored prostate cancer lesions in 163 consecutive patients (n = 110 cases, n = 53 controls) using the guideline of Prostate Imaging Reporting and Data System version 2 on multiparametric magnetic resonance imaging. The proposed modified kappa, which properly corrects for the amount of agreement by chance, is shown to be approximately equivalent to the ISA. In the prostate cancer data, average kappa, modified kappa, and ISA equaled 30%, 55%, and 57%, respectively, for all lesions and 20%, 87%, and 87%, respectively, for index lesions. The application of kappa could result in a substantial downward bias in reader agreement on lesion detection when locations are not prespecified. ISA is recommended for assessment of reader agreement on lesion detection. Published by Elsevier Inc.

  3. The impact of noisy and misaligned attenuation maps on human-observer performance at lesion detection in SPECT

    Science.gov (United States)

    Wells, R. G.; Gifford, H. C.; Pretorius, P. H.; Famcombe, T. H.; Narayanan, M. V.; King, M. A.

    2002-06-01

    We have demonstrated an improvement due to attenuation correction (AC) at the task of lesion detection in thoracic SPECT images. However, increased noise in the transmission data due to aging sources or very large patients, and misregistration of the emission and transmission maps, can reduce the accuracy of the AC and may result in a loss of lesion detectability. We investigated the impact of noise in and misregistration of transmission data, on the detection of simulated Ga-67 thoracic lesions. Human-observer localization-receiver-operating-characteristic (LROC) methodology was used to assess performance. Both emission and transmission data were simulated using the MCAT computer phantom. Emission data were reconstructed using OSEM incorporating AC and detector resolution compensation. Clinical noise levels were used in the emission data. The transmission-data noise levels ranged from zero (noise-free) to 32 times the measured clinical levels. Transaxial misregistrations of 0.32, 0.63, and 1.27 cm between emission and transmission data were also examined. Three different algorithms were considered for creating the attenuation maps: filtered backprojection (FBP), unbounded maximum-likelihood (ML), and block-iterative transmission AB (BITAB). Results indicate that a 16-fold increase in the noise was required to eliminate the benefit afforded by AC, when using FBP or ML to reconstruct the attenuation maps. When using BITAB, no significant loss in performance was observed for a 32-fold increase in noise. Misregistration errors are also a concern as even small errors here reduce the performance gains of AC.

  4. Development and psychometric testing of the 'Motivation and Self-Efficacy in Early Detection of Skin Lesions' index.

    Science.gov (United States)

    Dyson, Judith; Cowdell, Fiona

    2014-12-01

    To develop and psychometrically test the Motivation and Self-Efficacy in Early Detection of Skin Lesions Index. Skin cancer is the most frequently diagnosed cancer worldwide. The primary strategy used to prevent skin cancer is promotion of sun avoidance and the use of sun protection. However, despite costly and extensive campaigns, cases of skin cancer continue to increase. If found and treated early, skin cancer is curable. Early detection is, therefore, very important. The study was conducted in 2013. Instrument Development. A literature review and a survey identified barriers (factors that hinder) and levers (factors that help) to skin self-examination. These were categorized according to a the Theoretical Domains Framework and this formed the basis of an instrument, which was tested for validity and reliability using confirmatory factor analysis and Cronbach's alpha respectively. A five-factor 20-item instrument was used that tested well for reliability and construct validity. Test-retest reliability was good for all items and domains. The five factors were: (i) Outcome expectancies; (ii) Intention; (iii) Self-efficacy; (iv) Social influences; (v) Memory. The Motivation and Self-Efficacy in Early Detection of Skin Lesions Index provides a reliable and valid method of assessing barriers and levers to skin self-examination. The next step is to design a theory-based intervention that can be tailored according to individual determinants to behaviour change identified by this instrument. © 2014 John Wiley & Sons Ltd.

  5. Detection of Carious Lesions and Restorations Using Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Mohammad Naebi

    2016-01-01

    Full Text Available Background/Purpose. In terms of the detection of tooth diagnosis, no intelligent detection has been done up till now. Dentists just look at images and then they can detect the diagnosis position in tooth based on their experiences. Using new technologies, scientists will implement detection and repair of tooth diagnosis intelligently. In this paper, we have introduced one intelligent method for detection using particle swarm optimization (PSO and our mathematical formulation. This method was applied to 2D special images. Using developing of our method, we can detect tooth diagnosis for all of 2D and 3D images. Materials and Methods. In recent years, it is possible to implement intelligent processing of images by high efficiency optimization algorithms in many applications especially for detection of dental caries and restoration without human intervention. In the present work, we explain PSO algorithm with our detection formula for detection of dental caries and restoration. Also image processing helped us to implement our method. And to do so, pictures taken by digital radiography systems of tooth are used. Results and Conclusion. We implement some mathematics formula for fitness of PSO. Our results show that this method can detect dental caries and restoration in digital radiography pictures with the good convergence. In fact, the error rate of this method was 8%, so that it can be implemented for detection of dental caries and restoration. Using some parameters, it is possible that the error rate can be even reduced below 0.5%.

  6. Comparision between biphasic helical CT and dynamic gadolinium-enhanced MR in the detection and characterization of focal hepatic lesions in cirrhotic patients

    International Nuclear Information System (INIS)

    Puig, J.; Martin, J.; Donoso, L.; Falco, J.; Rue, M.

    1997-01-01

    To assess the agreement between biphasic helical computerized tomography (BHCT) and dynamic gadolinium-enhanced magnetic resonance (MR) in the detection and characterization of focal hepatic lesions in a group of cirrhotic patients. A prospective study was done in 50 cirrhotic patients suspected of having hepatocarcinoma (HC) on the basis of ultrasonographic images evaluated by means of BHCT and dynamic gadolinium-enhanced MR using fast low-angle shot (FLASH) sequences (110-135/4/90 degree centigree). The images were assessed jointly by four radiologists. Between the two techniques, a total of 83 lesions were detected. MR disclosed more lesions (n=79) than BHCT (n=67) (p<0.005). Moreover, 25 of the lesions that were visible by both techniques were more clearly evident in MR images (p<0.01). MR correctly classified 6 of 7 benign lesions (85%) and 49 of 66 malignant ones (74%). BHCT correctly classifed 2 of 7 benign lesions (28%) and 32 of 66 malignant ones (48%). The sensitivities of MR and BHCT for the characterization of these lesions were 74% and 48%, respectively (p=0.0009), while the respective specificities were 86% and 29% (P<0.001). Dynamic gadolinium-enhanced MR with FLASH sequences is more efficient than BHCT in the detection and characterization of focal lesions in cirrhotic patients. (Author) 37 refs

  7. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  8. The role of positron emission tomography in the detection of incidental gastrointestinal tract lesions in patients examined for lung cancer

    International Nuclear Information System (INIS)

    Isobe, Kazutoshi; Hata, Yoshinobu; Sakaguchi, Shinji; Takai, Yujiro; Shibuya, Kazutoshi; Takagi, Keigo; Homma, Sakae

    2010-01-01

    The purpose of this study was to clarify the clinical characteristics of lung cancer patients with abnormal accumulation in the gastrointestinal tract by fluoro-2-deoxyglucose positron emission tomography (PET). Of the 968 consecutive patients with primary lung cancer who underwent PET from October 2005 through September 2009, 26 patients had local abnormal accumulation in the gastrointestinal tract. We retrospectively compared the localization of abnormal accumulation in the gastrointestinal tract, standardized uptake value (SUV)max (1 hour), and the final clinical diagnosis. The site of abnormal accumulation was the esophagus in 1 case, the stomach in 8 and the small intestine to large intestine in 17. In 15 out of 26 (57%) cases with true PET positive results, there was esophageal cancer in 1 case, gastric cancer in 2, gastrointestinal stromal tumor in 1, colon cancer in 8, and 1 each of metastasis to the stomach, small intestine and large intestine from lung cancer. In 11 cases with false PET-positive results, there was a stomach polyp in 1 case, gastritis in 3, colon polyp in 1, diverticulitis in 1 and normal physiologic accumulation in 5. There were no differences in mean SUVmax among malignant lesions, benign lesions, and normal physiologic accumulation. We should perform endoscopy of the digestive tract to detect malignant lesions with high incidence rates when PET shows localalized abnormal accumulation in the gastrointestinal, tract in patients with lung cancer. (author)

  9. Utility of fractional anisotropy imaging analyzed by statistical parametric mapping for detecting minute brain lesions in chronic-stage patients who had mild or moderate traumatic brain injury

    International Nuclear Information System (INIS)

    Asano, Yoshitaka; Shinoda, Jun; Okumura, Ayumi; Aki, Tatsuki; Takenaka, Shunsuke; Miwa, Kazuhiro; Yamada, Mikito; Ito, Takeshi; Yokohama, Kazutoshi

    2012-01-01

    Diffusion tensor imaging (DTI) has recently evolved as valuable technique to investigate diffuse axonal injury (DAI). This study examined whether fractional anisotropy (FA) images analyzed by statistical parametric mapping (FA-SPM images) are superior to T 2 *-weighted gradient recalled echo (T2*GRE) images or fluid-attenuated inversion recovery (FLAIR) images for detecting minute lesions in traumatic brain injury (TBI) patients. DTI was performed in 25 patients with cognitive impairments in the chronic stage after mild or moderate TBI. The FA maps obtained from the DTI were individually compared with those from age-matched healthy control subjects using voxel-based analysis and FA-SPM images (p<0.001). Abnormal low-intensity areas on T2*GRE images (T2* lesions) were found in 10 patients (40.0%), abnormal high-intensity areas on FLAIR images in 4 patients (16.0%), and areas with significantly decreased FA on FA-SPM image in 16 patients (64.0%). Nine of 10 patients with T2* lesions had FA-SPM lesions. FA-SPM lesions topographically included most T2* lesions in the white matter and the deep brain structures, but did not include T2* lesions in the cortex/near-cortex or lesions containing substantial hemosiderin regardless of location. All 4 patients with abnormal areas on FLAIR images had FA-SPM lesions. FA-SPM imaging is useful for detecting minute lesions because of DAI in the white matter and the deep brain structures, which may not be visualized on T2*GRE or FLAIR images, and may allow the detection of minute brain lesions in patients with post-traumatic cognitive impairment. (author)

  10. Lesion size detection in geographic atrophy by polarization-sensitive optical coherence tomography and correlation to conventional imaging techniques.

    Science.gov (United States)

    Schütze, Christopher; Bolz, Matthias; Sayegh, Ramzi; Baumann, Bernhard; Pircher, Michael; Götzinger, Erich; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2013-01-28

    To investigate the reproducibility of automated lesion size detection in patients with geographic atrophy (GA) using polarization-sensitive spectral-domain optical coherence tomography (PS-OCT) and to compare findings with scanning laser ophthalmoscopy (SLO), fundus autofluorescence (FAF), and intensity-based spectral-domain OCT (SD-OCT). Twenty-nine eyes of 22 patients with GA were examined by PS-OCT, selectively identifying the retinal pigment epithelium (RPE). A novel segmentation algorithm was applied, automatically detecting and quantifying areas of RPE atrophy. The reproducibility of the algorithm was assessed, and lesion sizes were correlated with manually delineated SLO, FAF, and intensity-based SD-OCT images to validate the clinical applicability of PS-OCT in GA evaluation. Mean GA lesion size of all patients was 5.28 mm(2) (SD: 4.92) in PS-OCT. Mean variability of individual repeatability measurements was 0.83 mm(2) (minimum: 0.05; maximum: 3.65). Mean coefficient of variation was 0.07 (min: 0.01; max: 0.19). Mean GA area in SLO (Spectralis OCT) was 5.15 mm(2) (SD: 4.72) and 2.5% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area in intensity-based SD-OCT pseudo-SLO images (Cirrus OCT) was 5.14 mm(2) (SD: 4.67) and 2.7% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area of all eyes measured 5.41 mm(2) (SD: 4.75) in FAF, deviating by 2.4% from PS-OCT results (P = 0.89, Pearson correlation coefficient = 0.99, P < 0.01). PS-OCT demonstrated high reproducibility of GA lesion size determination. Results correlated well with SLO, FAF, and intensity-based SD-OCT fundus imaging. PS-OCT may therefore be a valuable and specific imaging modality for automated GA lesion size determination in scientific studies and clinical practice.

  11. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Sharma, Madhurima; Sandhu, Manavjit Singh; Gorsi, Ujjwal; Gupta, Dheeraj; Khandelwal, Niranjan

    2015-01-01

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to com