WorldWideScience

Sample records for scintillation proportional counter

  1. An integrated photosensor readout for gas proportional scintillation counters

    International Nuclear Information System (INIS)

    Lopes, J.A.M.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    A xenon gas proportional scintillation counter has been instrumented with a novel photosensor that replaces the photomultiplier tube normally used to detect the VUV secondary scintillation light. In this implementation, the collection grid of a planar gas proportional scintillation counter also functions as a multiwire proportional chamber to amplify and detect the photoelectrons emitted by a reflective CsI photocathode in direct contact with the xenon gas. This integrated concept combines greater simplicity, compactness, and ruggedness (no optical window is used) with low power consumption. An energy resolution of 12% was obtained for 59.6 keV x-rays

  2. Gas scintillation proportional counters for x-ray synchrotron applications

    International Nuclear Information System (INIS)

    Smith, A.; Bavdaz, M.

    1992-01-01

    Gas scintillation proportional counters (GSPCs) as x-ray detectors provide some advantages and disadvantages compared with proportional counters. In this paper the various configurations of xenon filled GSPC are described including both imaging and nonimaging devices. It is intended that this work be used to configure a GSPC for a particular application and predict its general performance characteristics. The general principles of operation are described and the performance characteristics are then separately considered. A high performance, imaging, driftless GSPC is described in which a single intermediate window is used between the PMT and gas cell

  3. Energy resolution limitations in a gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Simons, D.G.; de Korte, P.A.J.; Peacock, A.; Bleeker, J.A.M.

    1985-01-01

    An investigation is made of the factors limiting the energy resolution of a gas scintillation proportional counter (GSPC). Several of these limitations originate in the drift region of such a counter and data is presented, giving a quantitative description of those effects. Data is also presented of a GSPC without a drift region, that therefore largely circumvents most of those degrading factors. The results obtained so far indicate that in that detector the limitation to the resolution is most probably due to cleanliness of the gas. Further research is underway in order to assess quantitatively the limiting factors in such a driftless GSPC

  4. A pill-box design, flow type, gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Garg, S.P.; Sharma, R.C.; Bhati, S.; Somasundaram, S.

    1982-01-01

    A gas scintillation proportional counter of 'pill-box' design operated with argon + 2.5% nitrogen gas in continuous flow, has been developed. An energy resolution of 1.6% is obtained for 239 Pu α-particles emitted from a mixed nuclide source of 239 Pu- 241 Am- 244 Cm and injected into the counter parallel to the anode. The risetime of the scintillation pulse is found to be less than 0.5 μs. Measurements have been made of charge and light gain factors as a function of anode voltage. It is found that for a given anode voltage, the scintillation pulse amplitude increases sharply with the addition of nitrogen to argon and reaches a maximum at about 2.5% and then decreases slowly, whereas the charge pulse amplitude reduces monotonically. Nitrogen improvement factors with the addition of 2.5% nitrogen to argon are found to be different for two photomultipliers with different photocathode responses. The improvement in energy resolution as a result of addition of nitrogen to argon is discussed. Comments are made on the intrinsic energy resolution capabilities of such a counter. (orig.)

  5. The performance of the curved grid gas proportional scintillation counter in X-ray spectrometry

    International Nuclear Information System (INIS)

    Santos, J.M.F. dos; Bento, A.C.S.S.M.; Conde, C.A.N.

    1994-01-01

    The performance of a curved grid gas proportional scintillation counter filled with xenon at 1100 mbar and having a 25 mm diameter window is evaluated for X-rays in the 1-11 keV energy range. Energy resolutions of 8.0% were obtained for a 5.9 keV parallel X-ray beam entering the detector through the full size window. The variation of the energy resolution with the X-ray energy is studied and X-ray fluorescence spectra for samples like industrial coal, painted porcelain and car lubrication oil, are presented. (orig.)

  6. Light yield as a function of gas pressure and electric field in gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Favata, F.; Smith, A.; Bavdaz, M.; Kowalski, T.Z.

    1990-01-01

    We have investigated the dependence of the scintillation light output for Xe on gas pressure in the range 0.14-1.4 bar, using a gas scintillation proportional counter, in different experimental configurations. We have compared our work with that of previous workers, and have shown that both our results and the results of previous authors are compatible with the intrinsic light output being independent of gas pressure, with any observed dependence being a pure experimental effect due to the spectral response of the various UV detectors used. We also use our experimental data for determining the ratio between the cross section of the Xe 2 ** +Xe→Xe 2 * +Xe reaction and the rate of the Xe 2 ** →2Xe+γ UV reaction. (orig.)

  7. A primary scintillation gated high pressure position sensitive gas scintillation proportional counter (HPGSPC) for applications to x-ray astronomy

    International Nuclear Information System (INIS)

    Giarrusso, S.; Manzo, G.; Re, S.

    1985-01-01

    The authors describe a new instrument for x-ray astronomy. The instrument, based on a high pressure (5 atm.), xenon filled, position sensitive Gas Scintillation Proportional counter (HPGSPC) is expected to feature an energy resolution better than 4% at 60 keV, an angular resolution of approximately 20 arc-minutes over the full energy range (4 to 100 keV) and a field of view (FOV) of up to 30x30 degrees. A prototype flight unit of the gas cell on which the instrument is based is presently under technological development in the framework of the SAX project

  8. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  9. The x-ray spectrum of the Cygnus Loop measured with Gas Scintillation Proportional Counters

    International Nuclear Information System (INIS)

    Tsunemi, Hiroshi; Manabe, Makoto; Yamashita, Koujun; Koyama, Katsuji.

    1988-01-01

    We report the results of an observation of the whole Cygnus Loop performed with the Gas Scintillation Proportional Counters (GSPC) on board the Tenma satellite. Line emissions around 1.9 keV and 2.5 keV, probably originating from silicon and sulfur Kα line blends, were detected. The continuum spectrum in the energy range 1-3 keV can be represented by a thermal bremsstrahlung spectrum with a temperature of 7 x 10 6 K. This is the highest value for the Cygnus Loop reported so far. The Tenma data were also combined with those from a sounding rocket flight performed previously, in which a similar detector system was employed. Thus, we obtain a wide-band X-ray spectrum for the whole Cygnus Loop with the best energy resolution reported so far. The combined data could not be fitted by a single temperature component in the thermal collisional ionization equilibrium (CIE) model or a single-temperature nonequilibrium ionization (NEI) model. A good fit is obtained if at least two temperature components are included in both the CIE and NEI models. However, only the NEI model allows a self consistent interpretation. Taking into account the emission measures for both components, we can conclude that the low-temperature, high-density component arises mainly from the shell region and that the high-temperature, low-density component arises from the interior of the shell. (author)

  10. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellermann, E.W.; Bateman, J.E.; Connolly, J.F.

    1978-03-01

    The properties of a prototype gas proportional scintillation detector, for use in large numbers, are examined. The detector is designed to focus a light signal, which is proportional to ionisation loss, into a fibre optic lightguide. It is shown that a single charged particle traversing the detector produces enough light out of the lightguide to be seen by a TV camera. Problems of lifetime and large scale detector production are discussed. Properties of saturation, linearity, position sensitivity, and operating limits are examined. It is shown that an array of gas proportional scintillation detectors when used with fibre optic lightguides and TV camera readout could offer significant improvements in cost per area and reliability over a scintillator plus photomultiplier or a wire proportional chamber array. (author)

  11. Investigations of X-ray response of single wire anode Ar-N2 flow type gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Garg, S.P.; Sharma, R.C.

    1984-01-01

    The X-ray response of single wire anode gas scintillation proportional counters of two different geometries operated with argon+nitrogen gases in continuous flow has been investigated with wire anodes of diameters 25 μm to 1.7 mm. An energy resolution of 19% is obtained for 5.9 keV X-rays entering the counter perpendicular to the anode in pill-box geometry with 25 μm diameter anode. With cylindrical geometry counters energy obtained at 5.9 keV are 18%, 24% and 33% for 50 μm, 0.5 mm and 1.7 mm diameter anodes respectively. An analysis of the observed resolution shows that the contribution from photon counting statistics to the relative variance of scintillation pulses even for X-rays in Ar-N 2 single wire anode gas scintillation proportional counters is small and is not a limiting factor. The energy resolution with thicker anodes, where the contribution from the variance of the charge multiplication factor also has been minimised, is found to deteriorate mainly by the interaction in the scintillation production region. Comments are made on the possibility of improvement in energy resolution by suppression of pulses due to such interactions with the help of the pulse risetime discrimination technique. (orig.)

  12. Scintillation Counters

    Science.gov (United States)

    Bell, Zane W.

    Scintillators find wide use in radiation detection as the detecting medium for gamma/X-rays, and charged and neutral particles. Since the first notice in 1895 by Roentgen of the production of light by X-rays on a barium platinocyanide screen, and Thomas Edison's work over the following 2 years resulting in the discovery of calcium tungstate as a superior fluoroscopy screen, much research and experimentation have been undertaken to discover and elucidate the properties of new scintillators. Scintillators with high density and high atomic number are prized for the detection of gamma rays above 1 MeV; lower atomic number, lower-density materials find use for detecting beta particles and heavy charged particles; hydrogenous scintillators find use in fast-neutron detection; and boron-, lithium-, and gadolinium-containing scintillators are used for slow-neutron detection. This chapter provides the practitioner with an overview of the general characteristics of scintillators, including the variation of probability of interaction with density and atomic number, the characteristics of the light pulse, a list and characteristics of commonly available scintillators and their approximate cost, and recommendations regarding the choice of material for a few specific applications. This chapter does not pretend to present an exhaustive list of scintillators and applications.

  13. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellerman, E.W.; Bateman, J.E.; Connolly, J.F.

    1979-01-01

    The properties of a prototype gas proportional scintillation (GPS) detector module are described. The module (25X25X14cm 3 ) is intended to form the basic unit of large area (up to approximately 100 m 2 ) calorimetric cosmic ray burst detector. Ionisation from particle tracks in the module is collected onto a point electrode where the GPS signal is generated. A concave mirror focusses this point source onto the end of a fibre optic light guide. In the proposed large area detector these fibres are brought together onto a low light level TV camera which performs the readout. The prototype module has demonstrated an adequate light output for the detection of single muons by such a readout system and also permitted the investigation of the main operating parameters (gas mixture, EHT, pressure, etc) and operational requirements such as proportionality and long term stability. (Auth.)

  14. A nuclear proportional counter

    International Nuclear Information System (INIS)

    1973-01-01

    The invention relates to a nuclear proportional counter comprising in a bulb filled with a low-pressure gas, a wire forming an anode and a cathode, characterized in that said cathode is constituted by two plane plates parallel to each other and to the anode wire, and in that two branches of a circuit are connected to the anode wire end-portions, each branch comprising a pre-amplifier, a measuring circuit consisting of a differentiator-integrator-differentiator amplifier and a zero detector, one of the branches comprising an adjustable delay circuit, both branches jointly attacking a conversion circuit for converting the pulse duration into amplitudes said conversion circuit being followed by a multi-channel analyzer, contingently provided with a recorder [fr

  15. Proportional gas scintillation detectors and their applications

    International Nuclear Information System (INIS)

    Petr, I.

    1978-01-01

    The principle is described of a gas proportional scintillation detector and its function. Dependence of Si(Li) and xenon proportional detectors energy resolution on the input window size is given. A typical design is shown of a xenon detector used for X-ray spetrometry at an energy of 277 eV to 5.898 keV and at a gas pressure of 98 to 270 kPa. Gas proportional scintillation detectors show considerable better energy resolution than common proportional counters and even better resolution than semiconductor Si(Li) detectors for low X radiation energies. For detection areas smaller than 25 mm 2 Si(Li) detectors show better resolution, especially for higher X radiation energies. For window areas 25 to 190 mm 2 both types of detectors are equal, for a window area exceeding 190 mm 2 the proportional scintillation detector has higher energy resolution. (B.S.)

  16. Proportional counter end effects eliminator

    International Nuclear Information System (INIS)

    Meekins, J.F.

    1976-01-01

    An improved gas-filled proportional counter which includes a resistor network connected between the anode and cathode at the ends of the counter in order to eliminate ''end effects'' is described. 3 Claims, 2 Drawing Figures

  17. Scintillation counter, segmented shield

    International Nuclear Information System (INIS)

    Olson, R.E.; Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  18. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters; Comparacion de resultados de la medida radiactiva del Kr-85 ambiental por centelleo liquido y contadores proporcionales

    Energy Technology Data Exchange (ETDEWEB)

    Heras, M. C.; Perez, M. M.

    1983-07-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  19. Scintillation counter based radiation dosimeter

    International Nuclear Information System (INIS)

    Shin, Jeong Hyun

    2009-02-01

    The average human exposure per year is about 240mrem which is come from Radon and human body and terrestrial and cosmic radiation and man-made source. Specially radiation exposure through air from environmental radiation sources is 80mrem/yr(= 0.01mR/hr) which come from Terrestrial and cosmic radiation. Radiation dose is defined as energy deposit/mass. There are two major methods to detect radiation. First method is the energy integration using Air equivalent material like GM counter wall material. Second method is the spectrum to dose conversion method using NaI(Tl), HPGe. These two methods are using generally to detect radiation. But these methods are expensive. So we need new radiation detection method. The research purpose is the development of economical environmental radiation dosimeter. This system consists of Plastic/Inorganic scintillator and Si photo-diode based detector and counting based circuitry. So count rate(cps) can be convert to air exposure rate(R/hr). There are three major advantages in this system. First advantages is no high voltage power supply like GM counter. Second advantage is simple electronics. Simple electronics system can be achieved by Air-equivalent scintillation detector with Al filter for the same detection efficiency vs E curve. From former two advantages, we can know the most important advantages of the this system. Third advantage is economical system. The price of typical GM counter is about $1000. But the price of our system is below $100 because of plastic scintillator and simple electronics. The role of scintillation material is emitting scintillation which is the flash of light produced in certain materials when they absorb ionizing radiation. Plastic scintillator is organic scintillator which is kind of hydrocarbons. The special point are cheap price, large size production(∼ton), moderate light output, fast light emission(ns). And the role of Al filter is equalizing counting efficiency of air and scintillator for

  20. Improvements to well scintillation counters

    International Nuclear Information System (INIS)

    Farukhi, M.R.; Mataraza, G.A.; Wimer, O.D.

    1977-01-01

    This invention relates to the field of ionising radiation detection. It concerns in particular scintillation detectors of the type that is commonly used in conjunction with a photomultiplier tube and that is used for monitoring radiation, for instance in the clinical measurements of isotopes. This invention enables well scintillation counters to be made, characterised by a high efficiency in measuring the thindown rate of radio-pharmaceutical solutions and to resolve the distribution of energy emanating from the radioactive source. It particularly consists in improving the uniformity of the luminous efficiency, the quality of the resolution and the efficiency whilst improving the reception of light [fr

  1. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  2. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device.

    Science.gov (United States)

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A; Garty, Guy; Harken, Andrew; Brenner, David J

    2015-09-11

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n) 3 He and D(d,n) 3 He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9 Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  3. Position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit uses a conventional (low-resistance, metal-wire anode) counter for spatial resolution of an ionizing event along the anode, which functions as an RC line. A pair of preamplifiers at the anode ends act as stabilized active-capacitance loads, each comprising a series-feedback, low-noise amplifier and a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction of handling of the anodes, and stabilizes the anode resistivity at high count rates (>10 6 counts/sec). (author)

  4. Scintillation counter: photomultiplier tube alignment

    International Nuclear Information System (INIS)

    Olson, R.E.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into the sample receiving zone. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (auth)

  5. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  6. Designing an optimally proportional inorganic scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Jai, E-mail: jai.singh@cdu.edu.au [School of Engineering and IT, B-Purple-12, Faculty of EHSE, Charles Darwin University, NT 0909 (Australia); Koblov, Alexander [School of Engineering and IT, B-Purple-12, Faculty of EHSE, Charles Darwin University, NT 0909 (Australia)

    2012-09-01

    The nonproportionality observed in the light yield of inorganic scintillators is studied theoretically as a function of the rates of bimolecular and Auger quenching processes occurring within the electron track initiated by a gamma- or X-ray photon incident on a scintillator. Assuming a cylindrical track, the influence of the track radius and concentration of excitations created within the track on the scintillator light yield is also studied. Analysing the calculated light yield a guideline for inventing an optimally proportional scintillator with optimal energy resolution is presented.

  7. Designing an optimally proportional inorganic scintillator

    International Nuclear Information System (INIS)

    Singh, Jai; Koblov, Alexander

    2012-01-01

    The nonproportionality observed in the light yield of inorganic scintillators is studied theoretically as a function of the rates of bimolecular and Auger quenching processes occurring within the electron track initiated by a gamma- or X-ray photon incident on a scintillator. Assuming a cylindrical track, the influence of the track radius and concentration of excitations created within the track on the scintillator light yield is also studied. Analysing the calculated light yield a guideline for inventing an optimally proportional scintillator with optimal energy resolution is presented.

  8. Development of proportional counters using photosensitive gases and liquids

    International Nuclear Information System (INIS)

    Anderson, D.F.

    1984-10-01

    An introduction to the history and to the principle of operation of wire chambers using photosensitive gases and liquids is presented. Their use as light sensors coupled to Gas Scintillation Proportional Counters and BaF 2 , as well as their use in Cherenkov Ring imaging, is discussed in some detail. 42 references, 21 figures

  9. The Origins of Scintillator Non-Proportionality

    Science.gov (United States)

    Moses, W. W.; Bizarri, G. A.; Williams, R. T.; Payne, S. A.; Vasil'ev, A. N.; Singh, J.; Li, Q.; Grim, J. Q.; Choong, W.-S.

    2012-10-01

    Recent years have seen significant advances in both theoretically understanding and mathematically modeling the underlying causes of scintillator non-proportionality. The core cause is that the interaction of radiation with matter invariably leads to a non-uniform ionization density in the scintillator, coupled with the fact that the light yield depends on the ionization density. The mechanisms that lead to the luminescence dependence on ionization density are incompletely understood, but several important features have been identified, notably Auger-like processes (where two carriers of excitation interact with each other, causing one to de-excite non-radiatively), the inability of excitation carriers to recombine (caused either by trapping or physical separation), and the carrier mobility. This paper reviews the present understanding of the fundamental origins of scintillator non-proportionality, specifically the various theories that have been used to explain non-proportionality.

  10. Proportional counter system for radiation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, M; Okudera, S

    1970-11-21

    A gas such as Xe or Kr employed in counter tubes is charged into the counter tube of a gas-flow type proportional counter for radiation measurement and into a vessel having a volume larger than that of the counter tube. The vessel communicates with the counter tube to circulate the gas via a pump through both the vessel and tube during measurement. An organic film such as a polyester synthetic resin film is used for the window of the counter tube to measure X-rays in the long wavelength range. Accordingly, a wide range of X-rays can be measured including both long and short wavelengths ranges by utilizing only one counter tube, thus permitting the gases employed to be effectively used.

  11. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A critical evaluaton is presented of the actual state of investigations and explanations of the resolution and pulse height changes resulted in proportional counters from radiation intensity variations. (author)

  12. Liquid mixtures for scintillation counters

    International Nuclear Information System (INIS)

    Kauffmann, J.M.

    1975-01-01

    Liquid scintillators contain emulsifiers or combinations of these which can be used over a wide temperature range for a multitude of aqueous samples. These emulsifiers are block-polymerides with a nonhygroscopic center part of the chain of oxypropylene combinations recieved by addition of propylene oxide to both hydroxyl groups of a propylene-glycol nucleus and both ends of the center part of the chain terminating in hygroscopic poly(oxyethylene) groups. The length of the nonhygroscopic center part of the chain varies from about 800 to 3,000 or 4,000 in molecular weight. The hygroscopic poly(oxyethylene) end groups have a controlled length constituting about 10 to 80wt.% of the finished molecule. The most useful members of this group of co-polymerides possess a length of their poly(oxypropylene) chains corresponding to a value of y of about 15 to 56 and a length of their poly(oxyethylene)chains corresponding to values of x and z between 1 and 35 . All known fluorines can be used. With the scintillators the radioimmunoassay can also be carried through. (DG/PB) [de

  13. Calibration of the neutron scintillation counter threshold

    International Nuclear Information System (INIS)

    Noga, V.I.; Ranyuk, Yu.N.; Telegin, Yu.N.

    1978-01-01

    A method for calibrating the threshold of a neutron counter in the form of a 10x10x40 cm plastic scintillator is described. The method is based on the evaluation of the Compton boundary of γ-spectrum from the discrimination curve of counter loading. The results of calibration using 60 Co and 24 Na γ-sources are given. In order to eValuate the Compton edge rapidly, linear extrapolation of the linear part of the discrimination curve towards its intersection with the X axis is recommended. Special measurements have shown that the calibration results do not practically depend on the distance between the cathode of a photomultiplier and the place where collimated γ-radiation of the calibration source reaches the scintillator

  14. On timing properties of the SRPO-304 proportional counters

    International Nuclear Information System (INIS)

    Gusev, A.A.; Pugacheva, G.I.

    1979-01-01

    Data of measurements of the signal delay time and the time of development of the discharge in a proportional counter filled with 90% Xe + 10% CH 4 mixture at 0.3 atm are presented. The measurements were carried out on muons of cosmic rays. Signal delay distribution for the proportional counter are given relative to the time of passage through it of a charged particle. The data obtained shows that the average delay time is 0.8 μs when a particle passes near the counter centre, whereas when it passes near its side wall the average delay time is 1.5 μs. The investigation of the discharge development time distribution was carried out for two values of the discriminator threshold: 6 and 20 keV. It was determined that the discharge development time distribution depends but little on the place of particle passage in a counter. The average discharge development time is 1.5 μs, with the maximum time beina 4.3 μs. It is shown that the resolution time of logical circuits will be near 4 μs when the counter is combined with scintillation detectors

  15. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  16. Pulse triggering mechanism of air proportional counters

    International Nuclear Information System (INIS)

    Aoyama, T.; Mori, T.; Watanabe, T.

    1983-01-01

    This paper describes the pulse triggering mechanism of a cylindrical proportional counter filled with air at atmospheric pressure for the incidence of β-rays. Experimental results indicate that primary electrons created distantly from the anode wire by a β-ray are transformed into negative ions, which then detach electrons close to the anode wire and generate electron avalanches thus triggering pulses, while electrons created near the anode wire by a β-ray directly trigger a pulse. Since a negative ion pulse is triggered by a single electron detached from a negative ion, multiple pulses are generated by a large number of ions produced by the incidence of a single β-ray. It is therefore necessary not to count pulses triggered by negative ions but to count those by primary electrons alone when use is made of air proportional counters for the detection of β-rays. (orig.)

  17. Very large area multiwire spectroscopic proportional counters

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F.

    1981-01-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) succesfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm 2 with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results. (orig.)

  18. Very large area multiwire spectroscopic proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F. (Istituto di Astrofisica Spaziale, Frascati (Italy))

    1981-07-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) successfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm/sup 2/ with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results.

  19. Calibration of proportional counters in microdosimetry

    International Nuclear Information System (INIS)

    Varma, M.N.

    1982-01-01

    Many microdosimetric spectra for low LET as well as high LET radiations are measured using commercially available (similar to EG and G) Rossi proportional counters. This paper discusses the corrections to be applied to data when calibration of the counter is made using one type of radiation, and then the counter is used in a different radiation field. The principal correction factor is due to differences in W-value of the radiation used for calibration and the radiation for which microdosimetric measurements are made. Both propane and methane base tissue-equivalent (TE) gases are used in these counters. When calibrating the detectors, it is important to use the correct stopping power value for that gas. Deviations in y-bar/sub F/ and y-bar/sub D/ are calculated for 60 Co using different extrapolation procedures from 0.15 keV/μm to zero event size. These deviations can be as large as 30%. Advantages of reporting microdosimetric parameters such as y-bar/sub F/ and y-bar/sub D/ above a certain minimum cut-off are discussed

  20. Improvement of a gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Luo Zhiping; Liu Liye; Ma Jizeng; Chen Baowei; Iimoto, Takeshi; Kosako, Toshiso

    2008-01-01

    A prototype GSPC without the gas purification system was developed in China Institute for Radiation Protection (CIRP). Xenon filled GSPC has many advantages, including high energy resolution, large detection area, ability for implementing position sensitive detection, etc. It may find a wide application in low energy X-ray and γ-ray fields, e.g., astronomy X-ray detection, medical imaging. Further applications in neutron and charged heavy particle detection are also possible. Several tests for 241 Am and 55 Fe have been carried out to check out its preliminary performance. Currently the energy resolution is still far from expectation, nevertheless, the concept is proved to be promising and the experimental results suggest the way for further improvements. The possible ways for improvement of the detector performance are discussed in conclusion. This work was funded by National Natural Science Foundation of China. (author)

  1. Rate dependent image distortions in proportional counters

    International Nuclear Information System (INIS)

    Trow, M.W.; Bento, A.C.; Smith, A.

    1994-01-01

    The positional linearity of imaging proportional counters is affected by the intensity distribution of the incident radiation. A mechanism for this effect is described, in which drifting positive ions in the gas produce a distorting electric field which perturbs the trajectories of the primary electrons. In certain cases, the phenomenon causes an apparent improvement of the position resolution. We demonstrate the effect in a detector filled with a xenon-argon-CO 2 mixture. The images obtained are compared with the results of a simulation. If quantitative predictions for a particular detector are required, accurate values of the absolute detector gain, ion mobility and electron drift velocity are needed. ((orig.))

  2. Absolute calibration of TFTR helium proportional counters

    International Nuclear Information System (INIS)

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Loughlin, M.

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments

  3. CWRU multiwire proportional counter readout system

    International Nuclear Information System (INIS)

    Bevington, P.R.; Leskovec, R.A.

    1977-01-01

    An electronic system is described which translates pulses from individual wires of multiwire proportional counters into binary addresses indicating the location of the wires in the chambers. The system combines a fast (<100 ns) serial scan of an event buffer with parallel encoding to provide fast transfer of addresses (250 ns per hit). The buffer has provision for disabling the input less than 40 ns after detection of an event to suppress recording of multiple hits caused by individual events. The encoder can digitize the address of every hit encountered or just the first addresses of contiguous hits. The system includes a coincidence trigger for determining whether timing criteria have been satisfied between chambers and with external devices. Events which do not meet the coincidence criteria are typically reset within 400 ns. The addresses are transferred to a computer interface through CAMAC modules. Multiple buffering permits further data acquisition during CAMAC transfer cycles. (Auth.)

  4. Fabrication of preamplifier for proportional counter

    International Nuclear Information System (INIS)

    Lotfi, Y.; Yazdanpanah, M.; Talebi, B.; Mohammadi, A.; Etaati, Gh.

    2002-01-01

    We have tried to describe techniques of preamplifier fabrication for proportional counter. At first electronic circuit of preamplifier has been analyzed by means of Or cad 9.1. Then we assembled the circuit. Thereafter essential and standard parameters of preamplifier has been measured and compared with foreign made one, according to IEEE standard method. (IEEE Std 301-1988) Specification for our preamplifier is: 1. Rise time of output plus: 25 nsec. 2. Fall time of output pulse: 50μ sec. 3. Charge sensitive: 46.3 mV/pc. 4. Average noise: 500 ion pair (rms) 5. Count R ate L imit: 9.14*10 10 Count/sec. 6. Resolution: %1.3 7. Spectrum of Bf3 detector to 300μ Ci Am-Be source for this preamplifier is the same as foreign one. On the Whole comparison of this preamplifier with the foreign one shows that their parameters similarity is about %95

  5. Quality measurement by proportional counter with B

    International Nuclear Information System (INIS)

    Onizuka, Yoshihiko; Endo, Satoru; Tanaka, Kenichi

    2005-01-01

    The dosimetry of air and the tissue-equivalent phantom made of acryl are carried out by the tissue-equivalent proportional counter (TEPC) and TEPC with wall contained B, and both results were compared. The changes of quality with distance from the beam center are determined by the frequency mean renewal energy y F (y)and the dose mean renewal energy y D (y) as indicators of quality. Both y F (y)and y D (y) of tissue-equivalent phantom are larger than air, but very large change was not observed in all distance. The dose rate is determined by y D (y), the number of events and measurement time. Change of dose rate was larger than the change of quality. The maximum value of dose rate depended on γray and neutron beam showed at the point 2 cm away from the center. (S.Y.)

  6. X-ray proportional counter for the Viking Lander

    International Nuclear Information System (INIS)

    Glesius, F.L.; Kroon, J.C.; Castro, A.J.; Clark, B.C.

    1978-01-01

    A set of four sealed proportional counters with optimized energy response is employed in the X-ray fluorescence spectrometer units aboard the two Viking Landers. The instruments have provided quantitative elemental analyses of soil samples taken from the Martian surface. This paper discusses the design and development of these miniature proportional counters, and describes their performance on Mars

  7. Reduction of degraded events in miniaturized proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, R.; Kirsten, T. (Max Planck Inst. fuer Kernphysik, Heidelberg (Germany))

    1991-11-15

    A method to reduce the number of degraded events in miniaturized proportional counters is described. A shaping of the outer cathode leads to a more uniform gas gain along the counter axis. The method is useful in situations in which the total number of decay events is very low. The effects leading to degraded events are studied theoretically and experimentally. The usefulness of the method is demonstrated by using it for the proportional counter of the GALLEX solar neutrino experiment. (orig.).

  8. Construction and calibration studies of the SAPHIR scintillation counters

    International Nuclear Information System (INIS)

    Kostrewa, D.

    1988-03-01

    For the scintillation counter system of the SAPHIR detector at the stretcher ring ELSA in Bonn 50 time of flight counters and 12 trigger counters have been built. Each of them has two photomultipliers, one at each side. A laser calibration system with a pulsed nitrogen laser as central light source to monitor these photomultipliers has been optimized. It was used to adjust the photomultipliers and to test their long and short time instabilities. (orig.)

  9. Neutron dosimetry using proportional counters with tissue equivalent walls

    International Nuclear Information System (INIS)

    Kerviller, H. de

    1965-01-01

    The author reminds the calculation method of the neutron absorbed dose in a material and deduce of it the conditions what this material have to fill to be equivalent to biological tissues. Various proportional counters are mode with walls in new tissue equivalent material and filled with various gases. The multiplication factor and neutron energy response of these counters are investigated and compared with those obtained with ethylene lined polyethylene counters. The conditions of working of such proportional counters for neutron dosimetry in energy range 10 -2 to 15 MeV are specified. (author) [fr

  10. A proportional counter for efficient backscatter Moessbauer effect spectroscopy

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Cudny, W.; Holnicka, J.; Walentek, J.

    1979-01-01

    The authors present a novel gas-tight proportional counter with flat beryllium windows for backscatter Moessbauer spectroscopy. The krypton-filled counter has a geometry that approaches 2π and a resolution of 12% fwhm for the 14.4 keV line of 57 Fe, and is easy to manufacture. (Auth.)

  11. Test of long scintillating counter prototypes for CDF-II

    International Nuclear Information System (INIS)

    Budagov, Yu.; Chirikov-Zorin, I.; Pukhov, O.; Incagli, M.; Leone, S.; Menzione, A.; Pauletta, G.; Tokar, S.

    2000-01-01

    New type long (up to 3 m) scintillating counter prototypes, developed for CDF-II, have been tested. The shift-spectrum fiber ribbons were used for light collection, and modern ultra compact photomultipliers R5600 were used for light detection. The efficiency for m.i.p. was excellent for all prototypes. The light yield from the far end of the counters was found to be more than 20 photoelectrons

  12. Test of a large size acrylic scintillation counter

    International Nuclear Information System (INIS)

    Bertino, M.; De Zorzi, G.; Zanello, D.

    1984-01-01

    We have tested the behaviour of an acrylic scintillator measuring the attenuation length and the time resolution of a 7.8 m long counter. On a small sample the photon yield relative to the NE 110 plastic has been measured. (orig.)

  13. Position sensitive proportional counters as focal plane detectors

    International Nuclear Information System (INIS)

    Ford, J.L.C. Jr.

    1979-01-01

    The rise time and charge division techniques for position decoding with RC-line proportional counters are reviewed. The advantages that these detectors offer as focal plane counters for nuclear spectroscopy performed with magnetic spectrographs are discussed. The theory of operation of proportional counters as position sensing devices is summarized, as well as practical aspects affecting their application. Factors limiting the position and energy resolutions obtainable with a focal plane proportional counter are evaluated and measured position and energy loss values are presented for comparison. Detector systems capable of the multiparameter measurements required for particle identification, background suppression and ray-tracing are described in order to illustrate the wide applicability of proportional counters within complex focal plane systems. Examples of the use of these counters other than with magnetic spectrographs are given in order to demonstrate their usefulness in not only nuclear physics but also in fields such as solid state physics, biology, and medicine. The influence of the new focal plane detector systems on future magnetic spectrograph designs is discussed. (Auth.)

  14. Scintillation counter with MRS APD light readout

    International Nuclear Information System (INIS)

    Akindinov, A.; Bondarenko, G.; Golovin, V.; Grigoriev, E.; Grishuk, Yu.; Mal'kevich, D.; Martemiyanov, A.; Ryabinin, M.; Smirnitskiy, A.; Voloshin, K.

    2005-01-01

    START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor Structure), operated in the Geiger mode, which have 1mm 2 sensitive areas. START is assembled from a 15x15x1cm 3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10 -2 Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3kUSD/m 2

  15. New proportional counter assembly in Gliwice 14C laboratory

    International Nuclear Information System (INIS)

    Moscicki, W.; Zastawny, A.

    1977-01-01

    The design and parameters are described of a proportional counter for low level counting. The cathode tube 80 mm in diameter and 30 cm in length is made of pure copper. The anode is a tungsten wire 0.05 mm in diameter. The cathode tube is surrounded by a cylindrical ring container with mercury. The total volume of the counter is 1.5 l and it is filled with carbon dioxide. At a pressure of 1 at of CO 2 the counter background is 4.20+-0.05 cpm and contemporary 14 C net effect 10.22+-0.10 cpm; at a pressure of 2 at of CO 2 the background is 4.40+-0.05 cpm and the contemporary 14 C net effect 20.53+-10 cpm. The efficiency of the proportional counter is 88% in both cases. (J.B.)

  16. A lens-coupled scintillation counter in cryogenic environment

    International Nuclear Information System (INIS)

    Stoykov, A; Scheuermann, R; Amato, A; Bartkowiak, M; Konter, J A; Rodriguez, J; Sedlak, K

    2011-01-01

    In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts, operating at cryogenic and room temperatures respectively. The prototype detector consists of a plastic scintillator with glued-in wavelength-shifting fiber located inside a cryostat, a Geiger-mode Avalanche Photodiode (G-APD) outside the cryostat, and a lens system guiding the scintillation light re-emitted by the fiber to the G-APD through optical windows in the cryostat shields. With a 0.8 mm diameter multiclad fiber and a 1 mm active area G-APD the coupling efficiency of the 'lens light guide' is about 50%. A reliable performance of the detector down to 3 K is demonstrated.

  17. Multi-element proportional counter for radiation protection measurements

    International Nuclear Information System (INIS)

    Kliauga, P.; Rossi, H.H.; Johnson, G.

    1988-01-01

    This article discusses design modifications of a multi-element proportional counter. The original counter exhibited poor resolution, as measured by the width of the event-size spectrum for low-energy photons. It was also suspected that the field inside each volume was not sufficiently symmetric. Results of the modifications showed that a dramatic improvement in resolution could be obtained in the chamber with tissue-equivalent septa if their potentials were adjusted to obtain optimal resolution. The full width at half maximum then approached, although it did not equal, that of a standard spherical counter

  18. Risetime discrimination applied to pressurized Xe gas proportional counter for hard x-ray detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Doi, Kosei

    1978-01-01

    A high pressure Xe proportional counter has been developed for hard X-ray observation. This counter has better energy-resolving power than a NaI scintillation counter, and the realization of large area is relatively easy. This counter is constructed with a cylindrical aluminum tube, and this tube can be used at 40 atmospheric pressure. The detection efficiency curves were obtained in relation to gas pressure. It is necessary to reduce impurities in the Xe gas to increase the energy-resolving power of the counter. The increase of gas pressure made the resolving power worse. The characteristics of the counter were stable for at least a few months. The wave form discrimination was applied to reduce the background signals such as pulses caused by charged particles and gamma-ray. This method has been used for normal pressure counter, and in the present study, it was applied for the high pressure counter. It was found that the discrimination method was able to be applied to this case. (Kato, T.)

  19. Proton-recoil proportional counter tests at TREAT

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; Burrows, D.R.; DeVolpi, A.

    1979-01-01

    A methane filled proton-recoil proportional counter will be used as a fission neutron detector in the fast-neutron hodoscope. To provide meaningful fuel-motion information the proportional counter should have: a linear response over a wide range of reactor powers background ratio (the number of high energy neutrons detected must be maximized relative to low energy neutrons, and gamma ray sensitivity must be kept small); and a detector efficiency for fission neutrons above 1 MeV of approximately 1%. In addition, it is desirable that the detector and the associated amplifier/discriminator be capable of operating at counting rates in excess of 500 kHz. This paper reports on tests that were conducted on several proportional counters at the TREAT reactor

  20. The scintillation counter system at the SAPHIR detector

    International Nuclear Information System (INIS)

    Bour, D.

    1989-10-01

    The scintillation-counters system of the SAPHIR-detector at the stretcher accelerator ELSA in Bonn consists of 64 counters. It supplies a fast hadronic trigger and is utilizised for the particle identification by time of flight measurements. Prototypes of the counters (340x21.25 x 6.0 cm 3 ) had been tested. The contribution to the resolution of the time of flight measurement was measured to σ=125 ps, the effective light velocity to 17.5 ns/cm and the attenuation length of 7.8 m. A pion kaon separation is possible up to a momentum of 1 GeV/c with time of flight measurement. With the first photon-beam at SAPHIR the counters were tested, first triggers were obtained and evaluated. (orig.) [de

  1. DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    Science.gov (United States)

    Forouzan, Faezeh; Waker, Anthony J

    2018-01-10

    The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was investigated over a range of 20 keV (X-ray) to 0.661 MeV (Cs-137 gamma ray). Then, with both the counters used simultaneously, the neutron and gamma ray doses produced by a P385 Neutron Generator (Thermo Fisher Scientific) together with a Cs-137 gamma source were determined. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Digital signal processing for 3He proportional counters

    International Nuclear Information System (INIS)

    Takahashi, Hiroyuki; Kawarabayashi, Jun; Kurahashi, Tomohiko; Iguchi, Tetsuo; Nakazawa, Masaharu

    1994-01-01

    Numerical analysis of individual pulses from 3 He proportional counters has been performed. A parametric approach has been used for the identification of a charge particle track direction. Using area parameters, a clear separation of events was observed for the wall effect on a triton and a proton, respectively. ((orig.))

  3. Methods of calculus for neutron spectrometry in proportional counters

    International Nuclear Information System (INIS)

    Butragueno, J.L.; Blazquez, J.B.; Barrado, J.M.

    1976-01-01

    Response functions for cylindrical proportional counters with hidrogenated gases have been determined, taking in account only wall effect, by means of two independent calculus methods. One of them is a Montecarlo application and the other one analytical at all. Results of both methods have been compared. (author) [es

  4. Methods of calculus for neutron spectrometry in proportional counters

    International Nuclear Information System (INIS)

    Butragueno Casado, J.L.; Blazquez Martinez, J.B.; Barrado Menendez, J.M.

    1976-01-01

    Response functions for cylindrical proportional counters with hydrogenated gases have been determined, taking in account only wall effect, by means of two independent calculus methods. One of them is a Monte Carlo application and the other one analytica at all. Results of both methods have been compared. (Author)

  5. Pulse-shape discrimination in IAEA tritium proportional counters

    International Nuclear Information System (INIS)

    Florkowski, T.

    1981-01-01

    Two systems of pulse-shape discrimination (PSD) for the reduction of background in low-level proportional counters were tested. A tentative conclusion is drawn that both PSD systems, although they decrease slightly the meson background, do not bring improvement in the analytical accuracy

  6. Identification of irradiated spices with aid of scintillation counter

    International Nuclear Information System (INIS)

    Uusheimo, K.

    1989-08-01

    The aim off the work was to determine how one can identify gamma-irradiated spices with aid of a scintillation counter (LKB/Wallac 1219 RackBeta Spectral) by chemiluminescence measurements. Even though scintillation counters are more sensitive than real luminometers they have not been capable in identifying the irradiated spices after contact with photosensitizer like luminol, isoluminol and lucigenin presumably because the actual chemiluminescence reaction took place before the sample vial reached the measuring range. Whereas it was noticed that the identification of pure, dry allspice, black pepper, white peppar and cardemom was possible without any solutions when there were also present similar unirradiated spices. The identification was possible even after 23 weeks duration depending on the dose of the irradiation (10 kGy or 50 kGy) and the weight of the samples (1 g or 9 g). The duration of the investigation was 23 weeks

  7. Proportional counter response calculations for gallium solar neutrino detectors

    International Nuclear Information System (INIS)

    Kouzes, R.T.; Reynolds, D.

    1989-01-01

    Gallium bases solar neutrino detectors are sensitive to the primary pp reaction in the sun. Two experiments using gallium, SAGE in the Soviet Union and GALLEX in Europe, are under construction and will produce data by 1989. The radioactive /sup 71/Ge produced by neutrinos interacting with the gallium detector material, is chemically extracted and counted in miniature proportional counters. A number of calculations have been carried out to simulate the response of these counters to the decay of /sup 71/Ge and to background events

  8. Proportional counter with uniform electric field with Penning's mixture

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Zaremba, K.

    1984-01-01

    Some calculations are given and the design of proportional counters with a homogeneous electric field filled with Penning's mixtures, which ensure the best energy resolution is described. The counters with mixtures of Ne+Ar, Ne+CH 4 , Ne+CO 2 and Ar+C 2 H 2 have been checked. The admixtures (Ar, CH 4 , CO 2 , C 2 H 2 ) constitute from 0.1 to 2%, with pressure from 125 Tr to 760 Torr. The best energy resolution has been obtained for the mixture of Ne+1%CH 4 at the pressure of 190 Torr

  9. Solid scintillator 'Ready Cap' for measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Ijiri, Kenichi; Endo, Masashi; Nogawa, Norio; Tsuda, Shoko; Nakamura, Aiko; Morikawa, Naotake; Osaki, Susumu.

    1990-01-01

    'Ready Cap', a small plastic container coated with solid scintillator has recently been introduced (Beckman Instruments, Inc.). Pulse height spectra and counting efficiencies obtained with a liquid scintillator and Ready Cap using a liquid scintillation counter were compared for 15 different radionuclides. For radionuclides emitting low-energy β-rays or characteristic X-rays, the spectra for Ready Cap shifted toward the higher energy side compared with the spectra for the liquid scintillator. This tendency was reversed for the nuclides emitting higher-energy β-radiations ( 36 Cl and 32 P). Generally, counting efficiencies both in Ready Cap and in liquid scintillator increased with increase in the energy of β- or X-rays. For some nuclides, Ready Cap gave higher counting efficiencies and for others it gave lower values than in the liquid scintillator. However, the differences were not large within each nuclide. The use of Ready Cap is recommended for measurements of radionuclides when liquid scintillation cocktails have no means of waste disposal under the present Japanese radioisotope regulation. (author)

  10. Measurements of electron attachment by oxygen molecule in proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Tosaki, M., E-mail: tosaki.mitsuo.3v@kyoto-u.ac.jp [Radioisotope Research Center, Kyoto University, Kyoto 606-8501 (Japan); Kawano, T. [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292 (Japan); Isozumi, Y. [Radioisotope Research Center, Kyoto University, Kyoto 606-8501 (Japan)

    2013-11-15

    We present pulse height measurements for 5-keV Auger electrons from a radioactive {sup 55}Fe source mounted at the inner cathode surface of cylindrical proportional counter, which is operated with CH{sub 4} admixed dry air or N{sub 2}. A clear shift of the pulse height has been observed by varying the amount of the admixtures; the number of electrons, created in the primary ionization by Auger electrons, is decreased by the electron attachment of the admixtures during their drift from the place near the source to the anode wire. The large gas amplification (typically 10{sup 4}) in the secondary ionization of proportional counter makes it possible to investigate a small change in the number of primary electrons. The electron attenuation cross-section of O{sub 2} has been evaluated by analyzing the shifts of the pulse height caused by the electron attachment to dry air and N{sub 2}.

  11. Quench gases for xenon- (and krypton-)filled proportional counters

    International Nuclear Information System (INIS)

    Ramsey, B.D.; Agrawal, P.C.

    1988-01-01

    Xenon-filled proportional counters are used extensively in astronomy, particularly in the hard X-ray region. The choice of quench gas can have a significant effect on the operating characteristics of the instrument although the data necessary to make the choice are not easily obtainable. We present results which detail the performance obtained from both cylindrical and parallel field geometries for a wide variety of readily available, ultrahigh or research grade purity, quench gases. (orig.)

  12. Avalanche localization and its effects in proportional counters

    International Nuclear Information System (INIS)

    Fischer, J.; Okuno, H.; Walenta, A.H.

    1977-11-01

    Avalanche development around the anode wire in a gas proportional counter is investigated. In the region of proportional gas amplification, the avalanche is found to be well localized on one side of the anode wire, where the electrons arrive along the field lines from the point of primary ionization. Induced signals on electrodes surrounding the anode wire are used to measure the azimuthal position of the avalanche on the anode wire. Practical applications of the phenomena such as left-right assignment in drift chambers and measurement of the angular direction of the primary ionization electrons drifting towards the anode wire are discussed

  13. Secondary emission scintillation counter for microdosimetry at the nanometer level

    International Nuclear Information System (INIS)

    Goldhagen, P.

    1987-01-01

    The secondary emission scintillation (SES) counter is a device designed to count the positive ions of charged-particle tracks in gas volumes simulating sites in tissue with diameters of the order of 1 nanometer. Based on suggestions by H.H. Rossi and A.M. Kellerer, the basic idea of the device was developed by A. Kosiara, M. Biavati, and R.D. Colvett in the late 1970s. The device was substantially modified in 1982, but work on it was suspended before the new version could be tested, in order to devote full-time effort to rebuilding RARAF. Work resumed on the SES counter in 1986. A diagram of the prototype SES counter now being tested is shown. A weak electric field in the cylindrical collection region of the device drifts ions from a track to a small region (less than 1 mm) of high electric field where they are accelerated by several kilovolts onto a dynode, producing secondary electrons. The secondary electrons are then accelerated onto a plastic scintillator, and the resulting light is detected by a photomultiplier. The passage of a charged particle is established by a solid state detector, which triggers electronics detecting coincidences and measuring the timing and amplitude of pulses from the photomultiplier

  14. Stabilization of the photomultiplier gain of a liquid scintillation counter

    International Nuclear Information System (INIS)

    Alkhazov, I.D.; Dmitriev, V.D.; Kuznetsov, A.V.; Malkin, L.Z.; Petrov, B.F.; Sheremet'ev, A.K.; Shpakov, V.I.

    1987-01-01

    A stabilization system of photomultiplier gain, where light-emitting diode flashes have been used to obtain a reference signal, is described. The diode is placed just in the liquid scintilllator volume. The stabilization system contains several (according to the number of photomultipliers) identical channels, which of them consists of a colorimeter, a control trigger and an integrator with an operational amplifier. Increase of photomultiplier stability is reached by changing voltage of photomultiplier power according to the reference signal amplitude. The level of background and efficiency of neutron detection by a scintillation counter are unchanged when using the stabilization system for 10 days of measurements

  15. Nitrogen large area proportional counter with gas regeneration

    International Nuclear Information System (INIS)

    Leidner, L.; Sadri, E.

    1984-10-01

    A nitrogen large area proportional chamber with gas regeneration is introduced to measure alpha and beta/gamma activites. In contrast to the flow counters used till now the new detector is independent of an external gas supply. The gas amplification factor of nitrogen keeps constant up to an impurity of 2% of O 2 . Oxygen diffusing through unavoidable leakages into the counting gas is removed by an activated catalyzer using low temperature copper oxidation. Humidty is adsorbed by a molecular sieve. The closed counter consists of three components: the actual detector, a gas purification cartridge and a gas circulating pump. Finally, the report describes long run experiments being carried out with prototypes. (orig./HP) [de

  16. The suppression of destructive sparks in parallel plate proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Cockshott, R.A.; Mason, I.M.

    1984-02-01

    The authors find that high energy background events produce localised sparks in parallel plate counters when operated in the proportional mode. These sparks increase dead-time and lead to degradation ranging from electrode damage to spurious pulsing and continuous breakdown. The problem is particularly serious in low energy photon detectors for X-ray astronomy which are required to have lifetimes of several years in the high radiation environment of space. For the parallel plate imaging detector developed for the European X-ray Observatory Satellite (EXOSAT) they investigate quantitatively the spark thresholds, spark rates and degradation processes. They discuss the spark mechanism, pointing out differences from the situation in spark chambers and counters. They show that the time profile of the sparks allows them to devise a spark suppression system which reduces the degradation rate by a factor of ''200.

  17. A versatile gas-flow proportional counter for Moessbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bibicu, I., E-mail: bibicu@infim.ro [National Institute for Materials Physics (Romania); Nicolescu, G. [IFIN-HH, National Institute of Physics and Nuclear Engineering (Romania); Cretu, C. [Transylvania University, Physics Department (Romania)

    2009-07-15

    This article presents a versatile gas-flow proportional counter for surface and transmission Moessbauer spectroscopy, suitable for studies with {sup 57}Fe, {sup 119}Sn and {sup 151}Eu isotopes. The main advantages obtained by new design are: (1) the height of the detection volume can be changed in large limits from 0 to 38 mm, (2) the detection volume can be choose symmetrical or not in respect with anode plan, (3) the anode replacement is easily (4) and different anode configuration can be used. The characteristics of the detector, operating at room temperature, are reported.

  18. Xenon-based Penning mixtures for proportional counters

    International Nuclear Information System (INIS)

    Ramsey, B.D.; Agrawal, P.C.; National Aeronautics and Space Administration, Huntsville, AL

    1989-01-01

    The choice of quench gas can have a significant effect on the gas gain and energy resolution of gas-filed proportional counters. Details are given on the performance obtained with a variety of quench additives of varying ionization potentials for use in xenon-filled systems. It is confirmed that optimum performance is obtained when the ionization potential is closely matched to the first metastable level of xenon (8.3 eV) as is the case with xenon + trimethylamine and xenon + dimethylamine. For these mixtures the Penning effect is at its strongest. (orig.)

  19. A multiwire proportional counter for very high counting rates

    International Nuclear Information System (INIS)

    Barbosa, A.F.; Guedes, G.P.; Tamura, E.; Pepe, I.M.; Oliveira, N.B.

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10 6 counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10 7 events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author)

  20. A multiwire proportional counter for very high counting rates

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, A F; Guedes, G P [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Tamura, E [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil); Pepe, I M; Oliveira, N B [Bahia Univ., Salvador, BA (Brazil). Inst. de Fisica

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10{sup 6} counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10{sup 7} events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author) 13 refs., 6 figs.

  1. Computer simulation of gain fluctuations in proportional counters

    International Nuclear Information System (INIS)

    Demir, Nelgun; Tapan, . Ilhan

    2004-01-01

    A computer simulation code has been developed in order to examine the fluctuation in gas amplification in wire proportional counters which are common in detector applications in particle physics experiments. The magnitude of the variance in the gain dominates the statistical portion of the energy resolution. In order to compare simulation and experimental results, the gain and its variation has been calculated numerically for the well known Aleph Inner Tracking Detector geometry. The results show that the bias voltage has a strong influence on the variance in the gain. The simulation calculations are in good agreement with experimental results. (authors)

  2. Direct current stabilization of scintillation counters used for uranium prospecting

    International Nuclear Information System (INIS)

    Fraser, H.J.

    1976-01-01

    A simple system for stabilizing a scintillation counter is described which uses a dc light source (a green light emitting diode) to illuminate the photo-cathode of the photomultiplier used to detect γ-induced light pulses from the scintillator. Basically, the photomultiplier anode current due to the light emitting diode light is held constant by an automatic control loop acting on the eht voltage to keep the gain of the photomultiplier tube constant. However, because the temperature coefficient of the scintillator does not in general match that of the light emitting diode, further compensation is required to achieve constant γ pulse gain. This is provided by adding to the control circuit a current derived from the light emitting diode voltage which is an excellent measure of temperature; the use of this technique results in gain constancy to within +-1% in the 10-50 0 C ambient temperature range. Noise and countrate limitations are discussed and it is concluded that the system is generally applicable to uranium prospecting equipment. (Auth.)

  3. Use of the helium-3 proportional counter for neutron spectrometry

    International Nuclear Information System (INIS)

    Vialettes, H.; Le Thanh, P.

    1967-01-01

    Up to now, two methods have been mainly used for neutron spectrometry near nuclear installations: - photographic emulsion spectrometry - the so-called, 'multisphere' technique spectrometry. The first method, which is fairly difficult to apply, has a threshold energy of about 500 keV; this is a big disadvantage for an apparatus which has to be used for spectrometry around nuclear installations where the neutron radiation is very much degraded energetically. The second method does not suffer from this disadvantage but the results which it yields are only approximate. In order to extend the energy range of the neutron spectra studied with sufficient accuracy the use of a helium-3 proportional counter has been considered. This report presents the principles of operation of the helium-3 spectrometer, and the calculation methods which make it possible to take into account the two main effects tending to deform the spectra obtained: - energy absorption by the walls of the counter, - energy loss of the incident neutrons due to elastic collisions with helium-3 nuclei. As an example of the application, the shape of the neutron spectrum emitted by a polonium-lithium source is given; the results obtained are in excellent agreement with theoretical predictions. (authors) [fr

  4. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  5. A CMOS integrated timing discriminator circuit for fast scintillation counters

    International Nuclear Information System (INIS)

    Jochmann, M.W.

    1998-01-01

    Based on a zero-crossing discriminator using a CR differentiation network for pulse shaping, a new CMOS integrated timing discriminator circuit is proposed for fast (t r ≥ 2 ns) scintillation counters at the cooler synchrotron COSY-Juelich. By eliminating the input signal's amplitude information by means of an analog continuous-time divider, a normalized pulse shape at the zero-crossing point is gained over a wide dynamic input amplitude range. In combination with an arming comparator and a monostable multivibrator this yields in a highly precise timing discriminator circuit, that is expected to be useful in different time measurement applications. First measurement results of a CMOS integrated logarithmic amplifier, which is part of the analog continuous-time divider, agree well with the corresponding simulations. Moreover, SPICE simulations of the integrated discriminator circuit promise a time walk well below 200 ps (FWHM) over a 40 dB input amplitude dynamic range

  6. Process for the automatic compensation of spectral displacement based on quenching processes in a liquid scintillation counter

    International Nuclear Information System (INIS)

    Nather, R.E.

    1978-01-01

    In measurements in a liquid scintillation counter, the tritium or C 14 isotope to be examined is situated in a scintillator solution. It is excited according to the energy of the β particle to emit light. An electrical signal is proportional to the light signal, and from the former, selective counting in the β spectrum can be undertaken in an impulse height analyser. The influence of the quenching effects by colour quenching or chemical quenching would reduce the gain of the counter. To compensate for the displacement of the spectrum, the required adjustment of a system parameter is carried out by calibration with a sample of low quenching effect. The calibration process is directly set for the energy end-point of the spectrum. Well known processes can be used to determine the quenching effect of the quenching represented by the sample. For example, the system parameters can be the discriminator level of the counter window. (DG) 891 HP [de

  7. Low energy recoil detection with a spherical proportional counter

    Science.gov (United States)

    Savvidis, I.; Katsioulas, I.; Eleftheriadis, C.; Giomataris, I.; Papaevangellou, T.

    2018-01-01

    We present results for the detection of low energy nuclear recoils in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC). An 241Am-9Be fast neutron source is used in order to obtain neutron-nucleus elastic scattering events inside the gaseous volume of the detector. The detector performance in the keV energy region was measured by observing the 5.9 keV line of a 55Fe X-ray source, with energy resolution of 10% (σ). The toolkit GEANT4 was used to simulate the irradiation of the detector by an 241Am-9Be source, while SRIM was used to calculate the Ionization Quenching Factor (IQF), the simulation results are compared with the measurements. The potential of the SPC in low energy recoil detection makes the detector a good candidate for a wide range of applications, including Supernova or reactor neutrino detection and Dark Matter (WIMP) searches (via coherent elastic scattering).

  8. Digital signal processing for He3 proportional counter

    International Nuclear Information System (INIS)

    Zeynalov, Sh.S.; Ahmadov, Q.S.

    2010-01-01

    Full text : Data acquisition systems for nuclear spectroscopy have traditionally been based on systems with analog shaping amplifiers followed by analog-to-digital converters. Recently, however, new systems based on digital signal processing make possible to replace the analog shaping and timing circuitry the numerical algorithms to derive properties of the pulse such as its amplitude. DSP is a fully numerical analysis of the detector pulse signals and this technique demonstrates significant advantages over analog systems in some circumstances. From a mathematical point of view, one can consider the signal evolution from the detector to the ADC as a sequence of transformations that can be described by precisely defined mathematical expressions. Digital signal processing with ADCs has the possibility to utilize further information on the signal pulses from radiation detectors. In the experiment each step of the signal generation in the 3He filled proportional counter was described using digital signal processing techniques (DSP). The electronic system has consisted of a detector, a preamplifier and a digital oscilloscope. The pulses from the detector were digitized using a digital storage oscilloscope. This oscilloscope allowed signal digitization with accuracy of 8 bit (256 levels) and with frequency of up to 5 * 10 8 samples/s. As a neutron source was used Cf-252. To obtain detector output current pulse I(t) created by the motions of the ions/electrons pairs was written an algorithm which can easily be programmed using modern computer programming languages.

  9. The background of external γ radiation in the proportional counters in SAGE experiment

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.

    2003-01-01

    The influence of external γ radiation on the process of 71 Ge-decay counting in proportional counters in SAGE experiment of solar neutrino flux measurement is examined. One determines the systematic error of SAGE result, connected with radon decays inside the air volume surrounding the counters, and the background counting rate of proportional counters from γ radiation of passive and active shield [ru

  10. A 4π scintillation counter-optical spark chamber system for neutral particles

    International Nuclear Information System (INIS)

    Demarzo, C.; Distante, A.; Guerriero, L.; Niccolini, C.; Posa, F.; Walder, F.; Chen, G.T.Y.; Fletcher, C.R.; Lanou, R.E. Jr.; Thornton, R.K.; Barton, D.S.; Lyons, T.; Marx, M.; Rosenson, L.; Thern, R.

    1975-01-01

    The authors describe a scintillation counter-optical spark chamber system developed for the detection of high energy gamma rays and neutrons. They describe the system components and their use in two completed experiments. (Auth.)

  11. Digital signal processing for He3 proportional counter

    International Nuclear Information System (INIS)

    Ahmadov, Q.S.; Institute of Radiation Problems, ANAS, Baku

    2011-01-01

    Full text: Data acquisition systems for nuclear spectroscopy have traditionally been based on systems with analog shaping amplifiers followed by analog-to-digital converters. Recently, however, new systems based on digital signal processing allow us to replace the analog shaping and timing circuitry the numerical algorithms to derive properties of the pulse such as its amplitude. DSP is a fully numerical analysis of the detector pulse signals and this technique demonstrates significant advantages over analog systems in some circumstances. From a mathematical point of view, one can consider the signal evolution from the detector to the ADC as a sequence of transformations that can be described by precisely defined mathematical expressions.Digital signal processing with ADCs has the possibility to utilize further information on the signal pulses from radiation detectors [1] [2]. In the experiment each step of the signal generation in the 3He filled proportional counter was described using digital signal processing techniques (DSP). The electronic system has consisted of a detector, a preamplifier and a digital oscilloscope. The pulses from the detector were digitized using a OTSZS-02 (250USB)-4 digital storage oscilloscope from ZAO R UDNEV-SHILYAYEV . This oscilloscope allowed signal digitization with accuracy of 8 bit(256 levels) and with frequency of up to 5.10''8 samples/s. As a neutron source was used Cf-252.To obtain detector output current pulse I(t) created by the motions of the ions/electrons pairs was written an algorithm which can easily be programmed using modern computer programming languages

  12. Numerical modelling of tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Segur, P.; Colautti, P.

    1995-01-01

    In this paper a survey is given of the various numerical techniques employed to study the transport of ionising particles inside a TEPC. The first part is devoted to the description of the general concept of particle transport calculations. Thereafter, the different methods available to study transport phenomena and energy deposition in the sensitive volume and in counter walls are described. Finally, the basic ionisation mechanisms which may occur in a counter are described, and the non-equilibrium phenomena which play an important role mainly for counters that are to be used in measurements at the nanodosemeter level are studied. (author)

  13. A gaseous scintillation counter filled with He3 for neutron spectrometry

    International Nuclear Information System (INIS)

    Baldin, S.A.; Matveev, V.V.

    1962-01-01

    The paper describes a gas plant and gaseous scintillation counter, and gives the results of experiments on the recording and spectrometry of neutron beams using a gaseous scintillation counter filled with a mixture of 10% xenene and 90% helium-3 at an overall pressure of 20 ata. Data are given on the design of the gas plant, which makes it possible to operate the counter continuously over long periods of time, as well as providing the required gas mixtures at overall pressures of up to 60 atm and ensuring constant freedom of the gas from contamination. In addition, the paper presents the results of research on the counter's energy resolution and linearity at different energy levels and indicates its efficiency in gamma fields of intensity up to 3 r/h; the possibility of extending the working energy-range of gaseous scintillation counters filled with helium-3 is also considered. (author) [fr

  14. A theory of timing in scintillation counters based on maximum likelihood estimation

    International Nuclear Information System (INIS)

    Tomitani, Takehiro

    1982-01-01

    A theory of timing in scintillation counters based on the maximum likelihood estimation is presented. An optimum filter that minimizes the variance of timing is described. A simple formula to estimate the variance of timing is presented as a function of photoelectron number, scintillation decay constant and the single electron transit time spread in the photomultiplier. The present method was compared with the theory by E. Gatti and V. Svelto. The proposed method was applied to two simple models and rough estimations of potential time resolution of several scintillators are given. The proposed method is applicable to the timing in Cerenkov counters and semiconductor detectors as well. (author)

  15. Manual calibration of liquid scintillation counter using the channel ratio technique

    International Nuclear Information System (INIS)

    Moussa, H.M.; Townsend, L.; Miller, L.F.

    1999-01-01

    The objectives of this activity are to introduce students to liquid scintillation counting and to calibrate the counter using the sample channel ratio technique. This is accomplished by using quenched standards set for 14 C and tritium ( 3 H) to generate a quench correction curve for the scintillation solution. It is a good method for students to gain a detailed understanding of issues important to manual calibration of a liquid scintillation counter, and results can be compared with a built-in automatic method

  16. High resolution time-of-flight measurements in small and large scintillation counters

    International Nuclear Information System (INIS)

    D'Agostini, G.; Marini, G.; Martellotti, G.; Massa, F.; Rambaldi, A.; Sciubba, A.

    1981-01-01

    In a test run, the experimental time-of-flight resolution was measured for several different scintillation counters of small (10 x 5 cm 2 ) and large (100 x 15 cm 2 and 75 x 25 cm 2 ) area. The design characteristics were decided on the basis of theoretical Monte Carlo calculations. We report results using twisted, fish-tail, and rectangular light- guides and different types of scintillator (NE 114 and PILOT U). Time resolution up to approx. equal to 130-150 ps fwhm for the small counters and up to approx. equal to 280-300 ps fwhm for the large counters were obtained. The spatial resolution from time measurements in the large counters is also reported. The results of Monte Carlo calculations on the type of scintillator, the shape and dimensions of the light-guides, and the nature of the external wrapping surfaces - to be used in order to optimize the time resolution - are also summarized. (orig.)

  17. Performance of microstrip proportional counters for x-ray astronomy on spectrum-roentgen-gamma

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; BAHNSEN, A; Christensen, Finn Erland

    1991-01-01

    DSRI will provide a set of four imaging proportional counters for the Danish-Soviet X-ray telescopes XSPECT/SODART. The sensor principle is based on the novel micro-strip proportional counter (MSPC), where the strip electrodes are deposited by photolithography onto a rigid substrate. The MSPC off...

  18. Some aspects of the use of proton recoil proportional counters for fast neutron personnel dosimeters

    International Nuclear Information System (INIS)

    Yule, T.J.; Bennett, E.F.

    1984-01-01

    Gas-filled proton recoil proportional counters have been used extensively for the measurement of neutron spectra in degraded fission-spectrum environments. Some considerations relating to the use of these counters for personnel dosimetry are here described. High sensitivity and good accuracy in the determination of dose-equivalent can be obtained if relatively high pressure hydrogen-filled proportional counters are used as the active element in a dosimeter system

  19. Background of external γ radiation in the proportional counters of the SAGE experiment

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.

    2003-01-01

    The effect of external γ radiation on the process of counting 71 Ge decays in the proportional counters of the SAGE experiment measuring the solar-neutrino flux is considered. The systematic uncertainty in the SAGE result due to radon decays inside the air volume surrounding the counters is estimated. The background counting rate in the proportional counters that is caused by γ radiation from the enclosing shield is also determined

  20. Study of light collection uniformity dependence on reflector type in a large scintillation counter

    International Nuclear Information System (INIS)

    Astvatsaturov, R.G.; Ivanov, V.I.; Knapik, E.; Kramarenko, V.A.; Malakhov, A.I.; Khachaturyan, M.N.

    1977-01-01

    An investigation of the way to improve uniformity of light collection onto photoelectric multiplier photocathode, for the 100x10x2 cm scintillation counter, has been undertaken. Pulse amplitude versus the point, particles strike a scintillator, relationship, has been demonstrated for several types of reflectors. Used as reflectors were: white papar, aluminium foil, black papar and a combination of above reflectors. Experimental data analysis shows, that the combination of reflectors with different reflection coefficient, provides a means for 1,5 time improvement of counter light collection uniformity, with no impairment of amplitude characteristics

  1. Novel determination of protein, fat, and lactose of milk by liquid scintillation counter

    International Nuclear Information System (INIS)

    Noble, R.C.; Shand, J.H.; West, I.G.

    1981-01-01

    A method for routine determination of protein, fat, and lactose contents of milk is based on the ability of a scintillation counter to measure coloration or opalescence through attenuation of photons emitted from sealed miniature carbon-14 and hydrogen-3 radioactive standards. A series of simplified and accurate analytical procedures enable full advantage to be taken of the automatic facilities on the modern liquid scintillation counter. The methods provide several advantages over existing procedures. Accuracy of quantification was high as assessed by comparing the results with those derived by recommended Kjeldahl, Gerber, and colorimetric procedures for protein, fat, and lactose determinations, respectively

  2. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  3. Study of micro pixel photon counters for a high granularity scintillator-based hadron calorimeter

    International Nuclear Information System (INIS)

    D'Ascenzo, N.; Eggemann, A.; Garutti, E.

    2007-11-01

    A new Geiger mode avalanche photodiode, the Micro Pixel Photon Counter (MPPC), was recently released by Hamamatsu. It has a high photo-detection efficiency in the 420 nm spectral region. This product can represent an elegant candidate for the design of a high granularity scintillator based hadron calorimeter for the International Linear Collider. In fact, the direct readout of the blue scintillation photons with a MPPC is a feasible techological solution. The readout of a plastic scintillator by a MPPC, both mediated by the traditional wavelength shifting fiber, and directly coupled, has been systematically studied. (orig.)

  4. Proceedings of the symposium on measurements of neutron energy spectra using recoil proton proportional counters

    International Nuclear Information System (INIS)

    Urabe, Itsumasa

    1986-01-01

    This is a report of the symposium on measurements of neutron energy spectra using recoil proton proportional counters held at the Research Reactor Institute of Kyoto University on January 27 in 1986. An energy resolution, wall effects of response functions, n · γ discrimination methods and other fundamental properties of recoil proton counters are discussed for a new development of an application of this counter. (author)

  5. Performance of multiclad scintillating and clear waveguide fibers read out with visible light photon counters

    Energy Technology Data Exchange (ETDEWEB)

    Baumbaugh, B. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Erdman, J. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Gaskell, D. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Lu, Q. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Marchant, J. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Ruchti, R. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Wayne, M. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Cooper, C. (Department of Physics, Purdue University, West Lafayette, IN 47907 (United States)); Hinson, J. (Department of Physics, Purdue University, West Lafayette, IN 47907 (United States)); Koltick, D.S. (Department of Physics, Purdue University, West Lafayette, IN 47907 (United State

    1994-06-15

    Measurements have been made of the performance of scintillating fibers read out with visible light photon counters (VLPCs). The light yields of single-clad and multiclad scintillating fibers have been compared. The experiment consisted of 3 m long scintillating fibers of 830 [mu]m diameter optically coupled to 8 m long waveguide fibers of 965 [mu]m diameter read out with HISTE-IV VLPCs. For the case of multiclad scintillating fiber and waveguide, an average of 6.2 photoelectrons was detected from the far end of the scintillating fiber if the fiber end was unmirrored, and 10.2 photoelectrons if the fiber end was mirrored. With this substantial photoelectron yield, minimum-ionizing tracks can be easily detected in fiber arrays, and excellent performance characteristics are expected for the fiber trackers designed for the D0 experiment at the Fermilab Tevatron Collider and the SDC experiment at the SSC Laboratory. ((orig.))

  6. Multiwire proportional counter (lecture by an electromagnetic delay line)

    International Nuclear Information System (INIS)

    Bruere-Dawson, R.

    1989-01-01

    For track localisation of ionizing particles with multiwire proportional chamber, an electronic chain including amplifying, shaping and memorizing circuits is required for each wire. In order to lower the cost of this type of detector, an electromagnetic delay line is proposed among various possibilities. In this paper, different coupling modes between chamber and delay line are studied with their respective advantages. The realization of one meter long delay line with a unit delay time of 15 ns per cm is also presented [fr

  7. Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters

    International Nuclear Information System (INIS)

    Takeda, Naoto; Kudo, Katsuhisa; Kobayashi, Katsuhei; Yoshimoto, Takaaki

    2000-01-01

    The relative gas multiplication along the cylindrical axis of three 3 He proportional counters with different length were measured by using a thermal neutron beam at the Kyoto University Reactor and an ideal response function by taking into account the difference of pulse height spectra were measured by different length counters. The three 3 He proportional counters (model type of P4-0806, P4-0806 and P4-0808 manufactured by Reuter-Stokes) prepared for relative gas multiplication measurements had identical structure having cylindrical outer shells of 304 stainless steel except for different sensitive lengths of 10 cm, 15 cm and 20 cm, respectively. All counters were filled with 400 kPa of 3 He gas and 200 kPa of Ar gas. The pulse height distributions were measured by moving the counter in the direction of it's cylindrical axis perpendicular to the thermal neutron beam. The measured pulse heights corresponding to the full energy peaks at various entrance points were normalized to that of the whole counter irradiation. The results as a function of the distance from the bottom edge of the stainless steel cylinder are shown. The total transition region of gas gain corresponded to about 23 %, 15 % and 10 % of each nominal sensitive region corresponding to shot, middle and long counters. The ideal pulse height spectrum (dots) obtained by using proportional counters of 10 cm and 20 cm in nominal sensitive length to thermal neutron beam is shown in the paper in comparison to simulated one which was calculated assuming the constant gain within the sensitive region and zero gas gain outside the sensitive regions. The simulation realized the ideal response function fairly well. (S.Y.)

  8. Optical fibers and avalanche photodiodes for scintillator counters

    International Nuclear Information System (INIS)

    Borenstein, S.R.; Palmer, R.B.; Strand, R.C.

    1980-01-01

    Fine hodoscopes can be made of new scintillating optical fibers and one half inch end-on PMT's. An avalanche photodiode with small size and immunity to magnetic fields remains as a tempting new device to be proven as a photodetector for the fibers

  9. Design of nuclear pulse shaped circuit based on proportional counter

    International Nuclear Information System (INIS)

    Song Qianqian; Cheng Yi; Tuo Xianguo

    2011-01-01

    Use the self-developed proportional to sample gas tritium in environment and make the measurement. For this detector, a kind of pulse shape circuit based on second order active low pass filtering circuit realized filtering and shaping nuclear pulse by high-speed operational amplifier, with less stages that has been approved for filter Gaussian wave. Use Multisim 10.0 to simulate the different parameters of the filter circuit. The simulation result was consistent with the theoretical results. The experiments proved the feasibility of this circuit, and at the same time provided a convenient and reliable method for analysis and optimization of the nuclear pulse waveform in order for discriminating by MCA. (authors)

  10. Determination of optimum shape and dimensions of anode high-voltage isolators for gaseous proportional counters

    International Nuclear Information System (INIS)

    Jelen, K.; Jagusztyn, W.

    1975-01-01

    The influence of the shape and dimensions of the high-voltage anode-to-cathods isolator on the regularity of the electrostatic field distribution along the anode of a cylindrical gaseous proportional counter is studied. For a counter of fixed dimensions, the length and diameter of the glass isolators were optimized to disrupt as little as possible the regularity of the field distribution in the active volume of the counter. Results of calculations are in agreement with experimental data. The obtained results provide a basis for obtaining a correct ratio of the active volume of the counter to its total volume. (author)

  11. Proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons

    International Nuclear Information System (INIS)

    Marzec, J.; Pawlowski, Z.

    1982-01-01

    The work describes the construction of a proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons. It has been shown that in this counter filled with Penning's mixtures Ne+Ar+CO 2 , Ne+CH 4 and Ar+C 2 H 2 , much higher resolutions are obtained than in typical cylindrical counters. In the counter described filled with a mixture of Ne+1%CH 4 , a resolution of fwhm=10.5% has been obtained for E=5.9 keV. (orig.)

  12. Proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons

    Energy Technology Data Exchange (ETDEWEB)

    Marzec, J.; Pawlowski, Z. (Politechnika Warszawska (Poland). Inst. Radioelektroniki)

    1982-09-15

    The work describes the construction of a proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons. It has been shown that in this counter filled with Penning's mixtures Ne+Ar+CO/sub 2/, Ne+CH/sub 4/ and Ar+C/sub 2/H/sub 2/, much higher resolutions are obtained than in typical cylindrical counters. In the counter described filled with a mixture of Ne+1%CH/sub 4/, a resolution of fwhm=10.5% has been obtained for E=5.9 keV.

  13. Proportional counter with a wire-anode lying on the dielectric surface

    International Nuclear Information System (INIS)

    Strelkov, A.V.

    1983-01-01

    Proportional coUnter with wire-anode lying on the dielectric surface is described. The result of the accumulation of charges on the dielectric surface immediately near the wire-anode surface is that such a counter possesses electrostatic memory relative to distribution of the gas amplification coefficient along the anode. SUch a distribution can be received for example by means of irradiation by the neutrons or the γ-rays. The disposition of the wire-anode on the convex dielectric surface allows one to make the ring-shaped counters or the nonplane proportional chambers practically of any profile. However, the energy resolution of the counter with anode on the dielectric is worse than the resolution of counter with free anode particularly at the large gas amplification coefficient

  14. On the use of single large-area photodiodes in scintillation counters

    International Nuclear Information System (INIS)

    Morrell, C.

    1989-12-01

    The compilation of this review was originally intended to assess the possibility of using photodiode-based scintillation counters in fluorescence EXAFS (or FLEXAFS) systems as a low-cost alternative to photomultiplier-based counters. The X-ray energies encountered in FLEXAFS experiments range from a few keV to a few tens of keV, and detectors are required to have some energy resolution and/or high count-rate capability in order to optimize the quality of data collected. The results presented in the reviewed literature imply strongly that photodiodes do not compete successfully with photomultipliers in scintillation counting systems for X-ray energies below the order of 100keV, at least at the present stage of photodiode technology. Nevertheless it is likely that there are other applications requiring X-ray detectors for which a photodiode-based scintillation counter may be perfectly adequate, and it is therefore felt that such a review is still useful. In addition, large-area single photodiodes have much to offer as X-ray detectors in their own right, and several of the considerations regarding their use in scintillation counters are highly relevant to this application. (author)

  15. Gamma-ray scintillation counter hodoscope for the experiment S140

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    The experiment S140 was set-up in the East Hall (beam p14) by the CERN-Munich-Cracow Collaboration to study the production by negative kaons of a neutral meson associated to a Lambda. Here, the liquid hydrogen target (inside the horizontal black tube) is withdrawn from the surrounding cylindrical gamma-ray-measuring scintillation counter hodoscope.

  16. Space-charge effects of the proportional counters in a multiple-ionization chamber

    International Nuclear Information System (INIS)

    Mang, M.

    1993-01-01

    At the ALADIN spectrometer of the GSI in october 1991 for the first time the new multiple ionization chamber was applied, in the two anode planes of which are additional multiwire-proportional counters. The proportional counters are required in order to make the detection of light fragments (Z 4 gold projectiles per second by these positive space charges the homogeneous electric field of the MUSIC is disturbed. This effect is especially strong in the beam plane. As consequence of the space charge additionally electrons are focused on the proportional counter so that their amplitudes in dependence on the beam intensity increase up to the 2.5-fold. Furthermore the y coordinate is falsified, because the electrons are diverted to the medium plane. On the measurement of the x coordinate this diversion has with maximally 0.1% only a small influence. These space-charge effects can be qualitatively described by a schematic model, which assumes a stationary positive space charge. Additionally for the proportional counters, which are not in the beam plane, their resolution was determined. In these counters the space-charge effects are small, because essentially fewer particles are registrated than in the medium MWPC's. By this charges of fragments with Z<10 could be separated. The charge resolution amounted at lithium 0.8 charge units. The position resolution of the proportional counters in y direction was determined to less than 8 mm. The detection probability of the fragments amounts for lithium 90% and from boron all fragments are detected

  17. The Optimum Condition For Determination Of Radioactivity Of Pest Insects Labelled with P-32 By Using Liquid scintillation Counter

    International Nuclear Information System (INIS)

    Yarianto, S.; Susilo, Budi; Sutrisno, Singgih

    2002-01-01

    Tracer technique is needed in the control programe of pest insects especially for determining of its direction and dispersal. Radioisotopes of P-32 is frecuently used for labeling of pest insects. Liquid Scintillation Counter can be used effectively for measuring radioactivity of pest insects labelled by P-32. Optilnization of liquid compositions that consist of solvents. primary scintillation PPO and secondary scintillation POPOP were determined by examination of their compositions. Based on the research result obtained, composition of scintillator which had the highest efficiency. consists of P-Xylene solvent. primary scintillation PPO (5 g/l ) and secondary scintillation POPOP (0.5 g/l)

  18. CAMAC-system for calibration and control of experimental apparatus with scintillation counters

    International Nuclear Information System (INIS)

    Petrov, A.G.; Sinaev, A.N.

    1977-01-01

    The CAMAC-system is described, connected to the minicomputer PH-2116C, for calibration and control of an experiment on pion scattering on He-nuclei performed with a streamer chamber triggered by a scintillation hodoscope. The following operations are performed: -delay calibration in telescope and hodoscope tracts involving 22 scintillation counters; -control of relative efficiency of hodoscope counters and other parameters of the experiments; -control of HV supply of photomultipliers; -control of the currents of magnets and lenses of the muon track of the synchrocyclotron; -measurement of pulse-hight spectra from a Cherenkov counter to determine the beam composition. The working programs are initiated and the dialogue with the computer is carried out using an alphanumerical display connected to the PH-2116C via a CAMAC interface

  19. Tritium assay in hydrogen gas by proportional counter with magnetic tape recording

    International Nuclear Information System (INIS)

    Grabczak, J.

    1982-03-01

    Analytical procedure is discussed concerning routine tritium activity determination in water samples based on hydrogen production from the water sample and radioactivity measurement by gas proportional counting. The method was found to be fully comparable to the widely adopted technique of liquid scintillation counting with electrolytic enrichment

  20. Direct measurement of radioactive carbon in Vietnamese vodkas by Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Hattori, Takamitsu

    2014-01-01

    From the view point of applying to laboratory exercise of radioactivity measurement by a Liquid Scintillation Counter (LSC), Vietnamese vodkas have specific features as measurement samples, for example, they are colorless, have high ethanol content, and only very few organic materials are included. Investigation was made to make sure that the Vietnamese vodkas are appropriate or not as a measurement sample for the LSC exercise. Direct measurements of 14 C without any chemical pre-treatment were made on both radioactive concentrations and specific activities of three kinds of Vietnamese vodka and also pure ethanol reagent. The LSC measurements reveal that estimated 14 C concentration is proportional to ethanol content in samples and that specific activity of 14 C shows good agreement among the Vietnamese vodkas and pure ethanol, as well as the reference value of 0.25 Bq/g of Carbon. Thus the conclusion is derived that the Vietnamese vodkas can be applied with high accuracy to the LSC exercise as measurement samples. (author)

  1. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    Energy Technology Data Exchange (ETDEWEB)

    Tarifeño-Saldivia, Ariel, E-mail: atarifeno@cchen.cl, E-mail: atarisal@gmail.com; Pavez, Cristian; Soto, Leopoldo [Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4, Santiago (Chile); Departamento de Ciencias Fisicas, Facultad de Ciencias Exactas, Universidad Andres Bello, Republica 220, Santiago (Chile); Mayer, Roberto E. [Instituto Balseiro and Centro Atómico Bariloche, Comisión Nacional de Energía Atómica and Universidad Nacional de Cuyo, San Carlos de Bariloche R8402AGP (Argentina)

    2014-01-15

    This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods.

  2. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    International Nuclear Information System (INIS)

    Tarifeño-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo; Mayer, Roberto E.

    2014-01-01

    This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods

  3. Development of a drift tissue equivalent proportional counter for radiation protection personnel dosimetry

    International Nuclear Information System (INIS)

    Bordy, J.M.

    1992-04-01

    A new multicellular geometry for proportional counter has been developed. It is made of several drift regions which are some holes drilled in the cathode in front of anodes wires. The present work is made of 3 parts: 1) A theoretical evaluation of the multicellular counter characteristics: the sensitivity increases by a factor 15 vs the Tinelli Merlin-Gerin counter; the chord length distribution study shows the possibility to use a Dirac function for the dosimetry calculations; a tissue equivalent gas mixture based on argon and propane is designed. 2) The production of a monocellular prototype made of a hole and a needle shaped anode. 3) An experimental study of the prototype electrical characteristics and a computation of the electrical field in the counter. The focalization and the electron drift into the hole, the proportional operating mode are shown. Irradiations in front of photon and neutron sources verify these results

  4. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  5. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  6. Polyethylene vials for liquid scintillation counters produced by the National Materials Research Institute

    International Nuclear Information System (INIS)

    Fiser, B.; Lukas, D.

    1984-01-01

    The properties were tested of polyethylene vials for liquid scintillation counters manufactured by the National Materials Research Institute. Liquid scintillation counter ISOCAP 300 by Nuclear Chicago was used for measuring. For unquenched samples, channel A was set up to 0.5-3.6 keV and channel B to 0.5-18 keV. The scintillation solution was prepared of toluene, 4 g PPO, 0.15 g POPOP per 1 l of toluene. CCl 4 was used as the quenching agent. Radioactive samples were prepared from 20 μl of standard solution of [ 3 H]-toluene with specific activity of 349 Bq/g. All measurements were made using a 7 ml scintillation solution into which radioactivity and possibly quenching agents were added. Potassium-free glass vials by SKLO UNION Teplice and thin-walled polyethylene vials by Nuclear Chicago were used for comparison. The background was measured, as were the time dependences of weight losses of the scintillation solution and carbon tetrachloride from the counting vials, changes in efficiency in channel B with time, changes in SCR with time and changes in the quenching curve with time. (E.S.)

  7. The miniaturized proportional counter HD-2(Fe)/(Si) for the GALLEX solar neutrino experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wink, R.; Anselmann, P.; Doerflinger, D.; Hampel, W.; Heusser, G.; Kirsten, T.; Moegel, P.; Pernicka, E.; Plaga, R.; Schlosser, C. (Max Planck Inst. fuer Kernphysik, Heidelberg (Germany))

    1993-06-01

    The miniaturized proportional counters used for the detection of [sup 71]Ge in the solar neutrino project GALLEX are characterized. We also report on the construction techniques applied to build these counters and to achieve the described performance. A very low counting background is achieved by, among other things, careful selection of the materials used for construction. The total [sup 71]Ge detection efficiency after applying cuts to reduce the background is about 66%. (orig.).

  8. On the counting rate-dependent amplitude shifts in proportional counters

    International Nuclear Information System (INIS)

    Mahesh, K.

    1976-01-01

    The presence of a positive ion cloud near the anode wire, which has been believed to be the cause of the observed counting rate-dependent peak shifts in proportional counters, does not explain various exhibited features of these shifts. The possibility of other mechanisms involved is, therefore, examined. The columnar recombination of primary ions in the counter is considered to explain the origin of the shifts and their observed features. (Auth.)

  9. Absolute measurement of the activity of 222Rn using a proportional counter

    International Nuclear Information System (INIS)

    Busch, Ingo; Greupner, Heinz; Keyser, Uwe

    2002-01-01

    A measuring set-up comprising a proportional counter of calculable 222 Rn efficiency and quantifiable active volume (δ V 222 Rn efficiency is determined by computer simulation of the measured α-spectra. The procedures necessary for absolute measurements by means of the counter are described, and the suitability of the counter for absolute measurements of the 222 Rn activity is proved by experiments. Thus, a new method for the realization of the unit of activity of 222 Rn is obtained, which is independent of the unit of activity of 226 Ra

  10. Set-up of proportional counter L2 for 14C measurements with improved precision

    International Nuclear Information System (INIS)

    Goslar, T.; Pazdur, A.; Pazdur, M.F.; Walanus, A.; Zastawny, A.

    1990-01-01

    Radiocarbon dating with improved precision denotes determination of conventional radiocarbon dates with accuracy equal to ca ± 25 yr. The paper presents some fundamental data concerning construction and design of the proportional counter L2, the results of calibration of the counter, including detailed information on changes of the background counting rate. The counter L2 enables dating of samples up to 50 000 yr. For samples younger than 3000 yr the error of dating is equal to ca ± 25 yr. 4 figs., 1 tab., 9 refs. (author)

  11. Proton recoil spectra in spherical proportional counters calculated with finite element and Monte Carlo methods

    Energy Technology Data Exchange (ETDEWEB)

    Benmosbah, M. [Laboratoire de Chimie Physique et Rayonnement Alain Chambaudet, UMR CEA E4, Universite de Franche-Comte, 16 route de Gray, 25030 Besancon Cedex (France); Groetz, J.E. [Laboratoire de Chimie Physique et Rayonnement Alain Chambaudet, UMR CEA E4, Universite de Franche-Comte, 16 route de Gray, 25030 Besancon Cedex (France)], E-mail: jegroetz@univ-fcomte.fr; Crovisier, P. [Service de Protection contre les Rayonnements, CEA Valduc, 21120 Is/Tille (France); Asselineau, B. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN, Cadarache BP3, 13115 St Paul-lez-Durance (France); Truffert, H.; Cadiou, A. [AREVA NC, Etablissement de la Hague, DQSSE/PR/E/D, 50444 Beaumont-Hague Cedex (France)

    2008-08-11

    Proton recoil spectra were calculated for various spherical proportional counters using Monte Carlo simulation combined with the finite element method. Electric field lines and strength were calculated by defining an appropriate mesh and solving the Laplace equation with the associated boundary conditions, taking into account the geometry of every counter. Thus, different regions were defined in the counter with various coefficients for the energy deposition in the Monte Carlo transport code MCNPX. Results from the calculations are in good agreement with measurements for three different gas pressures at various neutron energies.

  12. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; Chen, Ningshun; Chokheli, Davit; Davydov, Yuri; Dukes, E. Craig; Dychkant, Alexsander; Ehrlich, Ralf; Francis, Kurt; Frank, M. J.; Glagolev, Vladimir; Group, Craig; Hansen, Sten; Magill, Stephen; Oksuzian, Yuri; Pla-Dalmau, Anna; Rubinov, Paul; Simonenko, Aleksandr; Song, Enhao; Stetzler, Steven; Wu, Yongyi; Uzunyan, Sergey; Zutshi, Vishnu

    2018-05-01

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.

  13. Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter

    CERN Document Server

    Aderholz, M; Matthewson, R; Lehraus, I no 1; Matthewson, R no 1; Aderholz, M no 1

    1975-01-01

    A Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A group of four identical scintillation counters was constructed and the smallest of the four output pulses was used for selective triggering of the bubble chamber flash with the greater precision engendered by the considerably reduced distribution width. (22 refs).

  14. Automation of a Beckman liquid scintillation counter for data capture and data-base management

    International Nuclear Information System (INIS)

    Neil, W.; Irwin, T.J.; Yang, J.J.

    1988-01-01

    A software package for the automation of a Beckman LS9000 liquid scintillation counter is presented. The package provides effective on-line data capture (with a Perkin Elmer 3230 32-bit minicomputer), data-base management, audit trail and archiving facilities. Key features of the package are rapid and flexible data entry, background subtraction, half-life correction, ability to queue several sample sets pending scintillation counting, and formatted report generation. A brief discussion is given on the development of customized data processing programs. (author)

  15. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    Science.gov (United States)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; Chen, Ningshun; Chokheli, Davit; Davydov, Yuri; Dukes, E. Craig; Dychkant, Alexsander; Ehrlich, Ralf; Francis, Kurt; Frank, M. J.; Glagolev, Vladimir; Group, Craig; Hansen, Sten; Magill, Stephen; Oksuzian, Yuri; Pla-Dalmau, Anna; Rubinov, Paul; Simonenko, Aleksandr; Song, Enhao; Stetzler, Steven; Wu, Yongyi; Uzunyan, Sergey; Zutshi, Vishnu

    2018-05-01

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120 GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions, reflective coating mixtures, and fiber diameters. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R&D program.

  16. Improving the performance of X-ray proportional counters by using field transistor preamplifiers

    International Nuclear Information System (INIS)

    Kalinina, N.I.; Mel'ttser, L.V.; Pan'kin, V.V.

    1972-01-01

    The possibility of using low-noise field-effect transistors with the n-channel in preamplifiers for x-ray proportional counters constitutes the object of this article. The operation of the preamplifier assembled according to the scheme of the voltage amplifier and charge-sensitive preamplifier has been studied. The use of the field-effect transistor with the n-channel in preamplifiers for proportional counters allows to improve significantly the energy resolution and operation at reduced voltage and at high loads. Notably good results have been obtained when constructing the circuit of the premplifier with the field-effect transistor on the charge-sensitive principle. The use of home-produced field-effect transistors makes it possible to construct detectors of roentgen radiometric instruments to measure light element content with proportional counters at reduced voltage

  17. Physical properties of the TOF (time of flight) scintillation counters of DELPHI

    International Nuclear Information System (INIS)

    Benlloch, J.M.; Castillo, M.V.; Ferrer, A.; Fuster, J.; Higon, E.; Llopis, A.; Salt, J.; Sanchez, E.; Sanchis, E.; Silvestre, E.; Cuevas, J.

    1990-01-01

    In this paper we report the physical properties of the time of flight (TOF) scintillator counters used for the DELPHI Experiment at CERN. We discuss the different choices studied for the wrapping of the counters in order to obtain best efficiencies for light transmission. A very good agreement of the performances of the counters has been found with the results of an original Monte Carlo program. The main characteristics of the TOF counters of DELPHI are: an effective light attenuation length of 135 cm, effective light speed of 15.91 cm/ns, a time resolution of 1.2 ns, and an efficiency for detection of minimum ionizing particles of 99.9%. (orig.)

  18. Novel concept for neutron detection: proportional counter filled with 10B nanoparticle aerosol

    Science.gov (United States)

    Amaro, F. D.; Monteiro, C. M. B.; dos Santos, J. M. F.; Antognini, A.

    2017-01-01

    The high neutron detection efficiency, good gamma-ray discrimination and non-toxicity of 3He made of proportional counters filled with this gas the obvious choice for neutron detection, particularly in radiation portal monitors (RPM), used to control the illicit transport of nuclear material, of which neutron detectors are key components. 3He is very rare and during the last decade this gas has become increasingly difficult to acquire. With the exception of BF3, which is toxic, no other gas can be used for neutron detection in proportional counters. We present an alternative where the 3He atoms are replaced by nanoparticles made of another neutron sensitive material, 10B. The particles are dispersed in a gaseous volume, forming an aerosol with neutron sensitive properties. A proportional counter filled with such aerosol was exposed to a thermal neutron beam and the recorded response indicates that the neutrons have interacted with the particles in the aerosol. This original technique, which transforms a standard proportional gas mixture into a neutron sensitive aerosol, is a breakthrough in the field of radiation detection and has the potential to become an alternative to the use of 3He in proportional counters. PMID:28181520

  19. Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting

    International Nuclear Information System (INIS)

    Vaca, F.; Garcia-Leon, M.

    1998-01-01

    In this paper a complete and self-consistent method for 90 Sr determination in environmental samples is presented. It is based on the Cherenkov counting of 90 Y with a conventional liquid scintillation counter. The effects of color quenching on the counting efficiency and background are carefully studied. A working curve is presented which allows to quantify the correction in the counting efficiency depending on the color quenching strength. (orig.)

  20. Measurement of Ra-226 in building materials, with a Na I (Tl) scintillation counter

    International Nuclear Information System (INIS)

    Vallejo, L.R.; Fuenteseca, J.W.; Rivera, C.A.; Aros, F.H.

    1992-01-01

    Ra-226 concentration in building materials is determined using gamma-ray spectrometry. Ra-226 contained in sundry materials employed in the construction of dwelling houses and public buildings in Antofagasta city is determined by counting the Pb-214 peaks at 295 KeV and 352 keV, and the Bi-214 peak at 609 keV recorded by means of a 7.5-cm Nal (TI) scintillation counter. (author)

  1. Low-pressure, multistep, multiwire proportional counter for the time-of-flight isochronous spectrometer

    International Nuclear Information System (INIS)

    Vieira, D.J.

    1985-01-01

    A low-pressure, multistep, multiwire proportional counter (MSMWPC) has been developed for the characterization and testing of the time-of-flight isochronous (TOFI) spectrometer and its associated secondary-beam transport line. This type of counter was selected because of its high sensitivity, large dynamic range, and good position (0.2 mm FWHM) and timing (180 ps FWHM) resolution. Furthermore, because the counter operates at low gas pressures (1-10 torr) and high electric-field strengths, which enable short collection times, it can be used as a transmission counter with thin gas-isolation windows and it can operate at high counting rates. Here the authors discuss the basic operating principle of the MSMWPC, describe the technical details of the detector and signal processing, and report on the performance they have measured for alpha particles and fission fragments

  2. Applications of commercial liquid scintillation counters to radon-222 and radium-226 analyses

    International Nuclear Information System (INIS)

    Gesell, T.F.; Prichard, H.M.; Haygood, J.R.

    1978-01-01

    The ubiquitous commerical liquid scintillation counter offers automatic sample processing, automatic data recording and the prospect of multiple users. With these features in mind we have explored a number of applications of liquid scintillation counters to environmental and health physics problems. One application, the analysis of radon in water has been described elsewhere and is only briefly reviewed. A method for measuring radon in air, two methods for measuring radium in water, and a technique for leak testing radium needles have also been investigated. An ordinary glass scintillation vial is readily converted into a miniature scintillation flask by coating the inside surface with a thin layer in ZnS:Ag phosphor. The lower limit detection is high, about 2 pCi/1 for a 1 hour count, but these flasks have proved to be useful in situations where a larger number of samples must be taken in environments with relatively high levels of radon. One technique for the detection of radium in water uses liquid-liquid extraction to concentrate radon into an organic scintillation fluid, the other involves passing the water sample through an ion exchange resin and then sealing the resin and scintillation fluid in a vial. Both techniques offer the prospect of easy and inexpensive analyses with limits of detection at or below 0.5 pCi/1. Radium needles can be leak tested by placing them in vials containing toluene for a few minutes, adding fluor to the toluene and counting. Preliminary data regarding these several methods are given

  3. Non-Proportionality of Electron Response and Energy Resolution of Compton Electrons in Scintillators

    Science.gov (United States)

    Swiderski, L.; Marcinkowski, R.; Szawlowski, M.; Moszynski, M.; Czarnacki, W.; Syntfeld-Kazuch, A.; Szczesniak, T.; Pausch, G.; Plettner, C.; Roemer, K.

    2012-02-01

    Non-proportionality of light yield and energy resolution of Compton electrons in three scintillators (LaBr3:Ce, LYSO:Ce and CsI:Tl) were studied in a wide energy range from 10 keV up to 1 MeV. The experimental setup was comprised of a High Purity Germanium detector and tested scintillators coupled to a photomultiplier. Probing the non-proportionality and energy resolution curves at different energies was obtained by changing the position of various radioactive sources with respect to both detectors. The distance between both detectors and source was kept small to make use of Wide Angle Compton Coincidence (WACC) technique, which allowed us to scan large range of scattering angles simultaneously and obtain relatively high coincidence rate of 100 cps using weak sources of about 10 μCi activity. The results are compared with those obtained by direct irradiation of the tested scintillators with gamma-ray sources and fitting the full-energy peaks.

  4. X-ray polarimetry with a conventional gas proportional counter through rise-time analysis

    CERN Document Server

    Hayashida, K; Tsunemi, H; Torii, K; Murakami, H; Ohno, Y; Tamura, K

    1999-01-01

    We have performed an experiment on the signal rise time of a Xe gas proportional counter using a polarized X-ray beam of synchrotron orbital radiation with energies from 10 to 40 keV. When the counter anode is perpendicular to the electric vector of the incident X-ray photons, the average rise time becomes significantly longer than that for the parallel case. This indicates that the conventional gas proportional counters are useful for X-ray polarimetry. The moderate modulation contrast of this rise-time polarimeter (M=0.1 for 10 keV X-rays and M=0.35 for 40 keV X-rays), with capability of the simultaneous measuring X-ray energies and the timing, would be useful for applications in X-ray astronomy and in other fields.

  5. Position-sensitive proportional counters using resistance-capacitance position encoding

    International Nuclear Information System (INIS)

    Kopp, M.K.; Borkowski, C.J.

    1975-12-01

    A new method was developed for encoding the position of individual photons, neutrons, or charged particles in proportional counters by using the distributed RC line characteristics of these counters. The signal processing is described and guidelines for the design and operation of these position sensitive proportional counters (PSPCs) are given. Using these guidelines, several prototypic PSPCs were constructed to improve the spatial resolution and shorten the signal processing time; for example, the intrinsic spatial uncertainty was reduced to 28 μ fwhm for alpha particles and 100 μ fwhm for low-energy x rays (2 to 6 keV). Also, the signal processing time was reduced to 0.6 μsec without seriously degrading the spatial resolution. These results have opened new fields of application of the RC position encoding method in imaging distributions of photons, charged particles, or neutrons in nuclear medicine, physics, and radiography

  6. Proportional Counter Calibration and Analysis for 12C + p Resonance Scattering

    Science.gov (United States)

    Nelson, Austin; Rogachev, Grigory; Uberseder, Ethan; Hooker, Josh; Koshchiy, Yevgen

    2014-09-01

    Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A objective of this project was to test the performance and perform position calibration of this proportional counter array. The test was done using 12C beam. The excitation function for 12C + p elastic scattering was measured and calibration of the proportional counter was performed using known resonances in 13N. The method of calibration, including solid angle calculations, normalization corrections, and position calibration will be presented. Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A objective of this project was to test the performance and perform position calibration of this proportional counter array. The test was done using 12C beam. The excitation function for 12C + p elastic scattering was measured and calibration of the proportional counter was performed using known resonances in 13N. The method of calibration, including solid angle calculations, normalization corrections, and position calibration will be presented. Funded by DOE and NSF-REU Program; Grant No. PHY-1263281.

  7. Investigation of the Pulse Height Distribution of Boron Trifluoride Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Malmskog, S

    1962-08-15

    The report describes a theoretical and experimental investigation of the factors that determine the pulse height distribution of BF{sub 3}, proportional counters irradiated by thermal neutrons. The branching ratio of the {sup 10}B (n,{alpha}) {sup 7}Li reaction for thermal neutrons has been measured.

  8. Removal of impurities from environmental water samples for tritium measurement by means of liquid scintillation counter

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Noda, Mitsuyasu

    2000-01-01

    Tritium concentration in environmental water samples is usually measured by means of liquid scintillation counting. Before the counting distillation operation is necessarily required to remove impurities, which have possibility of bad influence on the measurement, from the samples. But the operation usually takes long time and it is also troublesome. If you could simplify the purification process, you would be much easily able to measure it. Then, we have studied the probability of replacement the process by filtration aiming to simplify the procedure. We prepared several environmental water samples and also several water samples added quenching materials. These samples were purified by means of the distillation and the filtration and the impurities in them were examined. The purified samples were mixed with scintillation cocktail and the tritium concentration was measured. We added small amount of tritium in the same samples and investigated their scintillation spectra and their ESCR values in order to compare the two purification methods. Two kinds of filters were used for the filtration: 0.45 μm and 0.1 μm pore sized membrane filters. The liquid scintillation counter was LB-3 produced by Aloka Co. and Ltd. The scintillation cocktail was Ultima Gold LLT made by Packard Instrument Co and Ltd. The vial was Polyvial 145 LSD made by Zinsser Analytic Co. and Ltd. As the result, there was no significant difference between the two purification methods then the filtration method is feasible instead of the distillation. (author)

  9. Feasibility studies of high-pressure 4π proportional counter for absolute activity measurement

    International Nuclear Information System (INIS)

    Hino, Y.; Kawada, Y.

    1988-01-01

    A high-pressure proportional counter system is constructed. The high pressure 4πβ counter system constructed is made of aluminum and is divided into two 2π counters. The gas pressure is controlled with a pressure regulator and very fine leak valves to keep the balance of a stable pressure and constant flow rate. Investigation of characteristics of th counter shows that there is an almost linear relation between voltage and pressure. The linearlity of gas gain of this counter to the electron energies is measured with different gas pressures. Quite good linear gas multiplication is obtained at 0.9 MPa. Another investigation is made of application of to activity measurement of 109 Cd. When the gas pressure is over 0.5 MPa, the proportion of collected conversion electrons to absolute activity comes to a constant value of 96 %. This is quite good agreement with the decay data of 96.4 % conversion electron emission rate. The study indicated many excellent features for activity measurement. Especially the efficiency variation technique is good for automatic data acquisition with a programmable high voltage supplier. Moreover, since it is possible to obtain absolute activity with only one sample, it will be quite useful for limited samples experiments. (N.K.)

  10. Calibration of a liquid scintillation counter to assess tritium levels in various samples

    CERN Document Server

    Al-Haddad, M N; Abu-Jarad, F A

    1999-01-01

    An LKB-Wallac 1217 Liquid Scintillation Counter (LSC) was calibrated with a newly adopted cocktail. The LSC was then used to measure tritium levels in various samples to assess the compliance of tritium levels with the recommended international levels. The counter was calibrated to measure both biological and operational samples for personnel and for an accelerator facility at KFUPM. The biological samples include the bioassay (urine), saliva, and nasal tests. The operational samples of the light ion linear accelerator include target cooling water, organic oil, fomblin oil, and smear samples. Sets of standards, which simulate various samples, were fabricated using traceable certified tritium standards. The efficiency of the counter was obtained for each sample. The typical range of the efficiencies varied from 33% for smear samples down to 1.5% for organic oil samples. A quenching curve for each sample is presented. The minimum detectable activity for each sample was established. Typical tritium levels in bio...

  11. Position sensitive proportional counter for measurement of tritium labelled gas movement

    International Nuclear Information System (INIS)

    Mori, Chizuo; Nakamoto, Makihiko; Uritani, Akira; Watanabe, Tamaki

    1984-01-01

    A position sensitive proportional counter of a charge division type with a single resistive anode wire was constructed for the measurement of the movement of 3 H labelled gas which is flowing or diffusing in a pipe. The introduction of resistors between the anode wire and pre-amplifiers brought a uniform detection efficiency for 3 H β-rays throughout the counter. The position resolution was 3.1 mm FWHM. Detection efficiency was almost 100% uniformly over about 700 mm in the total anode length of 740 mm. The movement of 3 H labelled gas could be measured effectively. (author)

  12. Experimental dead time corrections for a linear position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Yelon, W.B.; Tompson, C.W.; Mildner, D.F.R.; Berliner, R.; Missouri Univ., Columbia

    1984-01-01

    Two simple counters included in the charge-digitization circuitry of a position-sensitive proportional counter using the charge division method for position encoding have enabled us to determine the dead time losses for the system. An interesting positional dependence of the dead time tau is observed, which agrees with a simple model. The system enables us to correct the experimental data for dead time and to be indifferent to the relatively slow analog-to-digital converters used in the system. (orig.)

  13. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    International Nuclear Information System (INIS)

    Tarifeño-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo; Mayer, Roberto E

    2015-01-01

    This work introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from detection of the burst of neutrons. An improvement of more than one order of magnitude in the accuracy of a paraffin wax moderated 3 He-filled tube is obtained by using this methodology with respect to previous calibration methods. (paper)

  14. New-generation large-area muon scintillation counters with wavelength shifter fiber readout for CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Chirikov-Zorin, I.

    2006-01-01

    New scintillation counters have been designed and constructed for upgrading of the CDF detector at the Fermilab Tevatron. A novel light collection technique using wavelength shifting fibers, together with a high-quality polystyrene-based scintillator UPS 923A, has resulted in compact counters with good and stable light collection efficiency over their lengths extending up to 320 cm. Design, construction and performance of counters are presented. Properties of the fibers and the scintillator, such as light output, light attenuation, decay time and long-term stability, are investigated. It is found that the polystyrene-based scintillator, unlike the polyvinyltoluene-based one, has better properties adequate for long-term experiments

  15. Measuring techniques for environmental sup 3 H, sup 14 C and sup 222 Rn by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Shigeru; Saito, Masaaki (Tokyo Metropolitan Isotope Research Center (Japan))

    1991-02-01

    Measuring techniques for environmental {sup 3}H, {sup 14}C and {sup 222}Rn with a liquid scintillation counter have been studied. {sup 3}H in environmental water was enriched by electrolysis and measured with a low background liquid scintillation counter. By this technique, {sup 3}H concentration of ground water, river water, sea water and rain water at Tokyo was founded to be 0.1 {approx} 2.5 Bq/1. {sup 14}C in taurine and ethyl-alcohol was measured directly liquid scintillation counter. By this {sup 14}C measuring, natural products, contain low level {sup 14}C, were distinguished from synthesised products contain no {sup 14}C. {sup 222}Rn in toluene extracted from environmental water or air was measured by scintillation pulse interval analysis method. By this technique, {sup 222}Rn was able to be measured under very low background counting rate, 0.03cpm, and high efficiency. (author).

  16. Use of the small gas proportional counters for the carbon-14 measurement of very small samples

    International Nuclear Information System (INIS)

    Sayre, E.V.; Harbottle, G.; Stoenner, R.W.; Otlet, R.L.; Evans, G.V.

    1981-01-01

    Two recent developments are: the first is the mass-spectrometric separation of 14 C and 12 C ions, followed by counting of the 14 C, while the second is the extension of conventional proportional counter operation, using CO 2 as counting gas, to very small counters and samples. Although the second method is slow (months of counting time are required for 10 mg of carbon) it does not require operator intervention and many samples may be counted simultaneously. Also, it costs only a fraction of the capital expense of an accelerator installation. The development, construction and operation of suitable small counters are described, and results of three actual dating studies involving milligram scale carbon samples will be given. None of these could have been carried out if conventional, gram-sized samples had been needed. New installations, based on the use of these counters, are under construction or in the planning stages. These are located at Brookhaven Laboratory, the National Bureau of Standards (USA) and Harwell (UK). The Harwell installation, which is in advanced stages of construction, will be described in outline. The main significance of the small-counter method is, that although it will not suffice to measure the smallest (much less than 10 mg) or oldest samples, it will permit existing radiocarbon laboratories to extend their capability considerably, in the direction of smaller samples, at modest expense

  17. 39Ar/Ar measurements using ultra-low background proportional counters

    International Nuclear Information System (INIS)

    Hall, Jeter; Aalseth, Craig E.; Bonicalzi, Ricco M.; Brandenberger, Jill M.; Day, Anthony R.; Humble, Paul H.; Mace, Emily K.; Panisko, Mark E.; Seifert, Allen

    2016-01-01

    Age-dating groundwater and seawater using the 39 Ar/Ar ratio is an important tool to understand water mass-flow rates and mean residence time. Low-background proportional counters developed at Pacific Northwest National Laboratory use mixtures of argon and methane as counting gas. We demonstrate sensitivity to 39 Ar by comparing geological (ancient) argon recovered from a carbon dioxide gas well and commercial argon. The demonstrated sensitivity to the 39 Ar/Ar ratio is sufficient to date water masses as old as 1000 years. - Highlights: • 39 Ar/Ar age dating is important for understanding environmental water migration. • Ultra low background proportional counters have been developed. • 39 Ar is detected in atmospheric argon at a rate of 70.3 counts per day. The demonstrated background is 166 counts per day. • Age dating is possible for water with underground residence time of up to 1000 years.

  18. Study and construction of an air proportional counter for superficial alpha contamination

    International Nuclear Information System (INIS)

    Cabral, T.S.

    1991-01-01

    Some properties of the proportional counters such as the working principle and the process of the gaseous multiplication are presented. Besides that, the project of Multiwire Proportional Counters is shown, which was tested with anodic wires of different diameters and with windows of several thicknesses. Operational characteristics of the detector were determined with the quoted variations. The chamber was normally operated by atmospheric pressure, but there were also made surveys on its behavior with oxygen, nitrogen and mixture of both. The performance of the chamber with a variations of temperature and relative humidity is analysed, because that is one of the biggest problems faced when measure of field are being made with this kind of detector. (author)

  19. Application of the finite-difference approximation to electrostatic problems in gaseous proportional counters

    International Nuclear Information System (INIS)

    Waligorski, M.P.R.; Urbanczyk, K.M.

    1975-01-01

    The basic principles of the finite-difference approximation applied to the solution of electrostatic field distributions in gaseous proportional counters are given. Using this method, complicated two-dimensional electrostatic problems may be solved, taking into account any number of anodes, each with its own radius, and any cathode shape. A general formula for introducing the anode radii into the calculations is derived and a method of obtaining extremely accurate (up to 0.1%) solutions is developed. Several examples of potential and absolute field distributions for single rectangular and multiwire proportional counters are calculated and compared with exact results according to Tomitani, in order to discuss in detail errors of the finite-difference approximation. (author)

  20. Study on the neutron dosimetric characteristics of Tissue Equivalent Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Nunomiya, T.; Kim, E.; Kurosawa, T.; Taniguchi, S.; Nakamura, T. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Tsujimura, N.; Momose, T.; Shinohara, K. [Japan Nuclear Cycle Development Inst., Environment and Safety Division, Tokai Works, Tokai, Ibaraki (Japan)

    1999-03-01

    The neutron dosimetric characteristics of TEPC (Tissue Equivalent Proportional Counter) has been investigated under a cooperative study between Tohoku University and JNC since 1997. This TEPC is a spherical, large volume, single-wire proportional counter (the model LETSW-5, manufactured by Far West Technology, Inc.) and filled with a tissue equivalent gas in a spherical detector of the A-150 tissue equivalent plastic. The TEPC can measure the spectra of absorbed dose in LET and easily estimate the tissue equivalent dose to neutron. This report summarizes the dosimetric characteristics of TEPC to the monoenergetic neutrons with energy from 8 keV to 15 MeV. It is found that TEPC can estimate the ambient dose equivalent, H*(10), with an accuracy from 0.9 to 2 to the neutron above 0.25 MeV and TEPC has a good counting efficiency enough to measure neutron doses with low dose rate at the stray neutron fields. (author)

  1. Demand-type gas supply system for rocket borne thin-window proportional counters

    Science.gov (United States)

    Acton, L. W.; Caravalho, R.; Catura, R. C.; Joki, E. G.

    1977-01-01

    A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.

  2. Output pulse-shapes of position-sensitive proportional counters using high resistance single wire

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Nishiyama, Fumitaka; Hasai, Hiromi

    1980-01-01

    The measurements and model analysis of the output pulse-shapes from a single wire proportional counter (SWPC) which has a high resistance anode are described. The characteristics of the observed pulse-shapes are determined by only one parameter which is a function of anode resistance and load resistance and they are reproduced by a simple model. Using this model, the methods for position read-out are discussed in a systematical way. (author)

  3. Test use of 'Ready Cap' for radiation measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Kato, Takahisa; Saito, Kazumi; Kurihara, Norio

    1989-01-01

    We tested the performance of 'Ready Cap' which can be used in place of liquid scintillation cocktails to measure the activity of 3 H and 14 C with a liquid scintillation counter, and observed satisfactory results on counting efficiencies for these nuclides. We could correct color-quenching with Ready Cap either by a method of the gravity-center of β-ray spectrum or by an external standard method that uses the external irradiation from bottom of the sample. Although there are several problems such as limitation of the maximum sample volumes (<200 μl) and sample preparation procedures (drying the sample solution), we can conveniently employ Ready Cap in some aspects of activity counting because of the easy disposal procedure of the radioactive waste resulting from it. (author)

  4. Detection of environmental radioactive contamination levels using a liquid-scintillation counter

    International Nuclear Information System (INIS)

    Calisto, W.; Kun, A.; Campos, E.

    1981-01-01

    A high-efficiency LS-100 C liquid scintillation counter was used to detect low levels of environmental activity. Different concentrations of primary scintillator were tested and these established the most suitable values. Work was carried out at the same time to find conditions which would ensure a low background and high efficiency. To reduce the sample volume used, various types of chelating agents were utilized: 8-hydroxyquinoline (oxine), tannic acid, cupferron, dimethylglioxime and beta-naphthol. These were tested at pH levels of 1, 6 and 11. Measurements were performed by means of the Cerenkov effect using substances with differing refraction indices - 26% sodium chloride, water, glycerine, carbon bisulphide, nitrobenzene, benzyl alcohol and toluene. Finally, work was done on comparing spectra obtained by Cerenkov radiation and by 90 Sr and 90 Y beta radiation respectively. Clearly differentiated zones were obtained, thus making it possible to distinguish one isotope from another in an equilibrium solution. (author)

  5. Scintillating fiber tracking at high luminosities using Visible Light Photon counter readout

    International Nuclear Information System (INIS)

    Atac, M.

    1995-11-01

    This paper reviews the research work on the Visible Light Photon Counters (VLPC) that have been developed for the scintillating fiber tracking at high luminosity colliders and high rate fixed target experiments. The devices originated from the joint work between UCLA and Rockwell International Science Center. The VLPCs are capable of counting photons very efficiently down to a single photon level with high avalanche gain, producing pulses at very high rates with very short rise times. Due to small gain dispersions they can be used in counting photons with high quantum efficiencies, therefore they are excellent devices for charged particle tracking using small diameter scintillating plastic fibers. In this paper, fiber tracking for the CDF and D0 upgrades and a possible usage of the VLPC readout for the experiment E803 at Fermilab will be discussed

  6. Data transfer from Beckman LS 5800 liquid scintillation counters to IBM personal computers.

    Science.gov (United States)

    Maan, A C

    1985-09-01

    This communication describes a short routine in BASICA for the IBM-PC, written to collect data from a Beckman liquid scintillation counter. In the form presented here the routine converts incoming bytes into separate lines and saves these lines in a file. There are many possible applications for further use of the data in these files. A few suggestions are given as to the format in which data can be stored and how to process these data automatically after all samples have been counted. The only hardware needed is an asynchronous communications adapter for the IBM-PC and an RS232 cable.

  7. A study of time over threshold (TOT) technique for plastic scintillator counter

    International Nuclear Information System (INIS)

    Wu Jinjie; Chinese Academy of Sciences, Beijing; Heng Yuekun; Sun Zhijia; Wu Chong; Yang Guian; Jiang Chun Hua; Zhao Yuda

    2008-01-01

    A new charge measurement method, time over threshold (TOT), has been used in some gas detectors lately. Here TOT is studied for TOF system, made of plastic scintillator counter, which can simplify the electronics of the system. The signal characteristics are measured and analyzed with a high quality oscilloscope, including noise, pedestal, signal amplitude, total charge, rise time and the correlation between them. The TOT and charge are related and can be fitted by some empirical formula. The charge measurement resolution by TOT is given and this will help the design of TOF electronics. (authors)

  8. Measurement of tissue free water tritium in biological samples by liquid scintillation counter

    International Nuclear Information System (INIS)

    Wu Zongmei; Zheng Xiaomin

    1993-01-01

    The authors introduced a method of extracting tissue free water tritium (TFWT) by the azeotropic distribution with toluene and of measuring the activity of the TFWT in biological samples by liquid scintillation counter. The TFWT recovery ratio of pine needles (fresh), green vegetables, radish, rice, pork (muscle) and milk is 0.90, 0.95, 0.96, 0.90, 0.52 and 0.85, and TFWT activity is 1.8, 3.2, 1.8, 2.7, 3.3 and 4.0 Bq/L-H 2 O, respectively

  9. Activity measurement of tritium in biological samples by azeotropic distillation liquid scintillation counter

    International Nuclear Information System (INIS)

    Wu Zongmei; Zheng Xiaomin

    1994-01-01

    The authors introduced a method of extracting tissue free water tritium (TFWT) in biological samples by azeotropic distillation with toluene and of measuring its activity by liquid scintillation counter. Measured TFWT recovery ratios of pine needles (fresh), green vegetables, radish, milk, meat, rice are 0.90, 0.95, 0.95, 0.85, 0.53 and 0.90; and the activities of TFWT are 1.8, 3.2, 1.8, 4.0, 3.3 and 2.7 Bq/L, respectively

  10. Response matrix of a multisphere neutron spectrometer with an 3 He proportional counter

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado S, G.A.

    2005-01-01

    The response matrix of a Bonner sphere spectrometer was calculated by use of the MCNP code. As thermal neutron counter, the spectrometer has a 3.2 cm-diameter 3 He-filled proportional counter which is located at the center of a set of polyethylene spheres. The response was calculated for 0, 3, 5, 6, 8, 10, 12, and 16 inches-diameter polyethylene spheres for neutrons whose energy goes from 10 -9 to 20 MeV. The response matrix was compared with a set of responses measured with several monoenergetic neutron sources. In this comparison the calculated matrix agrees with the experimental results. The matrix was also compared with the response matrix calculated for the PTB C spectrometer. Even though that calculation was carried out using a detailed model to describe the proportional counter; both matrices do agree, but small differences are observed in the bare case because of the difference in the model used during calculations. Other differences are in some spheres for 14.8 and 20 MeV neutrons, probably due to the differences in the cross sections used during both calculations. (Author) 28 refs., 1 tab., 6 figs

  11. Position-sensitive proportional counter with low-resistance metal-wire anode

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit is provided which uses a conventional (low-resistance, metal-wire anode) proportional counter for spatial resolution of an ionizing event along the anode of the counther. A pair of specially designed activecapacitance preamplifiers terminate the anode ends wherein the anode is treated as an RC line. The preamplifiers act as stabilized active capacitance loads and each is composed of a series-feedback, lownoise amplifier, a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at te anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction and handling of the anodes, and stabilizes the anode resistivity at high count rates

  12. Development of new type boron-coating proportional counter and its experimental investigation and simulation calculation

    International Nuclear Information System (INIS)

    Zhang Zixia; Wei Zhiyong; Fang Meihua; Qiang Peng; Zhu Li; Chen Guoyun

    2015-01-01

    Three materials wherein suitable proportion of isotope enriched 10 B powder, 1, 2-ethylene dichloride and formvar resin were blended to make 10 B neutron sensitive coating by oneself. A new type proportional counter that coated with 10 B neutron sensitive coating was made. Furthermore, in order to increase the character and quality of the neutron detector, a set of 14 annulus epoxy sheets which were sided with 10 B film were placed in the tube. A series performance tests were done by 241 Am-Be neutron source. The tests of 3.7 × 10 9 Bq 211 Am-Be neutron source show that the plateau length of detector is 150 V from 750 V to 900 V, while the plateau slope is 8.2%/100 V. When the working voltage is 800 V, the count rate of new type boron-coating proportional counter is 50 s -1 . The level of sensitivity is 0.71 cm 2 . Compared with the detector only coated with 10 B film in the inner walls of detector, neutron sensitivity area of the new detector increases to 3.15 times. The results show that the plateau length increases from 80 V to 150 V, and the plateau slope is improved from 12.4%/100 V to 7.58%/100 V, while the neutron sensitivity increases to 2.63 times. Using Geant4 software based on Monte Carlo method, this paper presented the response and detection efficiency of new type boron-coating proportional counter, which was covered with φ55 mm × 250 mm cylinder high density polyethylene moderator material. The simulation results of Geant4 are in agreement with the results of 241 Am-Be neutron source experiment. It shows the reliability of simulation application. (authors)

  13. Pulse-duration discrimination for increasing counting characteristic plateau and for improving counting rate stability of a scintillation counter

    International Nuclear Information System (INIS)

    Kuz'min, M.G.

    1977-01-01

    For greater stability of scintillation counters operation, discussed is the possibility for increasing the plateau and reducing its slope. Presented is the circuit for discrimination of the signal pulses from input pulses of a photomultiplier. The counting characteristics have been measured with the scintillation detectors being irradiated by different gamma sources ( 60 Co, 137 Cs, 241 Am) and without the source when the scintillation detector is shielded by a tungsten cylinder with a wall thickness of 23 mm. The comparison has revealed that discrimination in duration increase the plateau and reduces its slope. Proceeding from comparison of the noise characteristics, the relationship is found between the noise pulse number and gamma radiation energy. For better stability of the counting rate it is suggested to introduce into the scintillation counter the circuit for duration discrimination of the output pulses of a photomultiplier

  14. Direct measurement of gaseous activities by diffusion-in long proportional counter method

    International Nuclear Information System (INIS)

    Yoshida, M.; Yamamoto, T.; Wu, Y.; Aratani, T.; Uritani, A.; Mori, C.

    1993-01-01

    Direct measurement of gaseous activities by the diffusion-in long proportional counter method (DLPC method) was studied. The measuring time without end effect was estimated by observing the behavior of 37 Ar in the counter and was long enough to carry out the accurate activity measurement. The correction for wall effect was also examined on the basis of the measured and calculated correction factors. Among the tested gases of methane, P10 gas and propane, P10 gas was made clear to be a suitable counting gas for the DLPC method because of good diffusion properties and small wall effect. This method is quite effective for standardization of gaseous activities used for tracer experiments and calibration works of radioactive gas monitoring instruments. (orig.)

  15. Identification of relativistic charged particles by means of ionisation energy loss in proportional counters

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1978-12-01

    A method is described of obtaining a useful degree of improvement in the particle discrimination capability of multiwire proportional counters. The normal multiple sampling technique using a suitable bias to combat the small magnitude of the relativistic rise in the ionization energy loss and the wide pulse height distributions obtained in thin gas counters requires a large number of samples for useful discrimination. In the method reported, this number is reduced by suppressing the delta ray contribution to the total charge pulse from the anode wire. A monte carlo model convoluting the 'delta ray suppressed' data from a one sample detector shows that when it is required to separate pions and electrons at 1 GeV/C with a detection efficiency for the electron of 90%, a 'suppressor' circuit can achieve a pion rejection ratio of 250:1 with 82 samples, whereas the truncated mean approach (lowest 70% of samples) requires 100 samples. (UK)

  16. The accurate measurement of the disintegration rate of 55Fe using an internal liquid scintillation counter

    International Nuclear Information System (INIS)

    Botha, S.M.

    1979-01-01

    As the well-known 4πX-γ-coincidence method cannot be used directly to find the disintegration rate of 55 Fe, another method was developed in which a tracer nuclide, possessing coincident gamma radiation, was used. It was now possible to determine the disintegration rate indirectly by the coincidence method using an internal liquid scintillation counter. 54 Mn and 51 Cr which lie in the immediate vicinity of iron in the series of nuclides, are suitable tracers. They are also electron capture nuclides, but decaying to an excited state, were counted by the 4πX-γ-coincidence method. A mixed source, containing 55 Fe and the tracer, was also counted by the coincidence method so that the 4π-counting rate of 55 Fe was obtained as function of the tracer's counting efficiency. It was also essential to find a relationship between the counting efficiencies of the liquid scintillation counter for 55 Fe and the tracer. This relationship is called the effeciency function. Efficiency functions were calculated for 55 Fe and 54 Mn as well as for 55 Fe and 51 Cr. Finally the radioactive concentration of a solution of 55 Fe had been carefully determined by using 54 Mn and 51 Cr tracers. The results for the two different tracers agreed within the statistical uncertainty of 0,4%. The systematic uncertainty on the final results was estimated as 0,17%

  17. Excitonic processes and their contribution to non-proportionality observed in the light yield of inorganic scintillators

    International Nuclear Information System (INIS)

    Singh, J.; Koblov, A.

    2013-01-01

    Using the derived expression for the light yield in a scintillator, the influence of linear radiative and non-radiative (quenching) rates on the non-proportionality in light yield is studied. It is found that if the excitation created within the electron track initiated by a γ-photon incident on a scintillator, remains mainly excitonic, then non-proportionality can be minimized by inventing a scintillator material with linear radiative rate > 10 7 s -1 , linear quenching rate 6 s -1 and track radius ≥ 70 nm along with maintaining the rates of other non-linear processes as discovered earlier. If one can increase the linear radiative rate to 10 9 s -1 , then the non-proportionality can be eliminated at a track radius > 20 nm. (authors)

  18. The Rutherford Appleton Laboratory's Mark I Multiwire Proportional Counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1983-01-01

    A small model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on Multiwire Proportional Counter technology it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. A complete hardware system and sufficient software was provided to permit hospital based colleagues to generate useful images easily. A complete description of the system is given with performance figures and some of the images obtained are presented. (author)

  19. Radiation protection instruments based on tissue equivalent proportional counters: Part II of an international intercomparison

    International Nuclear Information System (INIS)

    Alberts, W.G.; Dietz, E.; Guldbakke, S.; Kluge, H.; Schumacher, H.

    1988-04-01

    This report describes the irradiation conditions and procedures of Part II of an international intercomparison of tissue-equivalent proportional counters used for radiation protection measurements. The irradiations took place in monoenergetic reference neutron fields produced by the research reactor and accelerator facilities of the PTB Braunschweig in the range from thermal neutrons to 14.8 MeV. In addition measurements were performed in 60 Co and D 2 O-moderated 252 Cf radiation fields. Prototype instruments from 7 European groups were investigated. The results of the measurements are summarized and compared with the reference data of the irradiations. (orig.) [de

  20. Use of tissue equivalent proportional counters to characterize radiation quality on the space shuttle

    International Nuclear Information System (INIS)

    Braby, L.A.; Conroy, T.J.; Elegy, D.C.; Brackenbush, L.W.

    1992-04-01

    Tissue equivalent proportional counters (TEPC) are essentially cavity ionization chambers operating at low pressure and with gas gain. A small, battery powered, TEPC spectrometer, which records lineal energy spectra at one minute intervals, has been used on several space shuttle missions. The data it has collected clearly show the South Atlantic anomaly and indicate a mean quality factor somewhat higher than expected. An improved type of instrument has been developed with sufficient memory to record spectra at 10 second intervals, and with increased resolution for low LET events. This type of instrument will be used on most future space shuttle flights and in some international experiments

  1. Neutron spectrometry with proton recoil proportional counters at the research and measurement reactor Braunschweig - status of the technique

    International Nuclear Information System (INIS)

    Knauf, K.; Wittstock, J.

    1987-07-01

    This status report is concerned with the facilities set up for neutron spectrometry at the Research and Measurement Reactor Braunschweig, based on proton recoil proportional counters. Cylindrical counters for irradiation by a neutron beam normal to the counter wire and commercial spherical counters are employed. They can be filled with hydrogen or a hydrogeneous gas up to a pressure of 1 MPa depending on their use. The filling method and the electronic pulse processing are described. The pulse analysis system includes a pulse shape discrimination branch in order to separate γ-ray induced pulses. Finally, experimental investigations with spherical counters are discussed regarding the region of proportionality and the influence of the counter voltage on the shape of the response function. (orig./HP) [de

  2. A helium-3 proportional counter technique for estimating fast and intermediate neutrons

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Nakazawa, Masaharu; Sekiguchi, Akira; Wakabayashi, Hiroaki.

    1976-11-01

    3 He proportional counter was employed to determine the fast and intermediate neutron spectra of wide energy region. The mixed gas ( 3 He, Kr) type counter response and the spectrum unfolding code were prepared and applied to some neutron fields. The counter response calculation was performed by using the Monte Carlo code, paying regards to dealing of the particle range calculation of the mixed gas. An experiment was carried out by using the van de Graaff accelerator to check the response function. The spectrum unfolding code was prepared so that it may have the function of automatic evaluation of the higher energy spectrum's effect to the pulse hight distribution of the lower energy region. The neutron spectra of the various neutron fields were measured and compared with the calculations such as the discrete ordinate Sn calculations. It became clear that the technique developed here can be applied to the practical use in the neutron energy range from about 150 KeV to 5 MeV. (auth.)

  3. Annular shape silver lined proportional counter for on-line pulsed neutron yield measurement

    International Nuclear Information System (INIS)

    Dighe, P.M.; Das, D.

    2015-01-01

    An annular shape silver lined proportional counter is developed to measure pulsed neutron radiation. The detector has 314 mm overall length and 235 mm overall diameter. The central cavity of 150 mm diameter and 200 mm length is used for placing the neutron source. Because of annular shape the detector covers >3π solid angle of the source. The detector has all welded construction. The detector is developed in two halves for easy mounting and demounting. Each half is an independent detector. Both the halves together give single neutron pulse calibration constant of 4.5×10 4 neutrons/shot count. The detector operates in proportional mode which gives enhanced working conditions in terms of dead time and operating range compared to Geiger Muller based neutron detectors

  4. Proton-recoil proportional-counter array for neutron-image construction

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; DeVolpi, A.

    1984-01-01

    The fuel-motion measurement capability of the fast-neutron hodoscope has been upgraded by the addition of a 360-detector proton-recoil proportional-counter array, which detects high-energy fission neutrons. The current sensitive amplifier/discriminator module for each detector fits into a 12.7 by 12.7 by 102 mm package and cost less than $100 per module. It has a 50 ns rise time, a noise level of 100 nA, and a deadtime per event of 200 ns. Provision has been provided for the independent adjustment of the input current versus discriminator voltage for each module. The new proportional-counters cost approximately $400 each. Each detector has been tested to have the same gain versus voltage response. A space-charge model relating count-rate changes to space-charge effects has also been developed. The new detector array has been operational for approximately two years and has become the main detector system in fuel-motion analysis. It has significantly improved the linearity, stability, count-rate capability, and setup ease of the hodoscope

  5. Calibration of an ultra-low-background proportional counter for measuring 37Ar

    International Nuclear Information System (INIS)

    Seifert, A.; Aalseth, C. E.; Bonicalzi, R. M.; Bowyer, T. W.; Day, A. R.; Fuller, E. S.; Haas, D. A.; Hayes, J. C.; Hoppe, E. W.; Humble, P. H.; Keillor, M. E.; LaFerriere, B. D.; Mace, E. K.; McIntyre, J. I.; Merriman, J. H.; Miley, H. S.; Myers, A. W.; Orrell, J. L.; Overman, C. T.; Panisko, M. E.

    2013-01-01

    An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with 14 C/ 3 H, age-dating of groundwater with 39 Ar, and soil-gas assay for 37 Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of 37 Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of 37 Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for 37 Ar soil gas background studies

  6. Electronic system for recording proportional counter rare pulses with the pulse shape analysis

    International Nuclear Information System (INIS)

    Barabanov, I.R.; Gavrin, V.N.; Zakharov, Yu.I.; Tikhonov, A.A.

    1984-01-01

    The anutomated system for recording proportional counter rare pulses is described. The proportional counters are aimed at identification of 37 Ar and H7 1 Gr decays in chemical radiation detectors of solar neutrino. Pulse shape recording by means of a storage oscilloscope and a TV display is performed in the system considered besides two-parametric selection of events (measurement of pulse amplitude in a slow channel and the amplitude of pulse differentiated with time constant of about 10 ns in a parallel fast channel). Pulse discrimination by a front rise rate provides background decrease in the 55 Fe range (5.9 keV) by 6 times; the visual analysis of pulse shapes recorded allows to decrease the background additionally by 25-30%. The background counting rate in the 55 Fe range being equal to 1 pulse per 1.5 days, is obtained when using the installation described above, as well as the passive Pb shield 5 cm thick, and the active shield based on the anticoincidence NaI(Tl) detector with the cathode 5.6 mm in-diameter made of Fe fabircated by zone melting. The installation described allows to reach the background level of 0.6 pulse/day (the total coefficient of background attenuation is 400). Further background decrease is supposed to be provided by installation allocation in the low-noise underground laboratory of the Baksan Neutrino Observatory

  7. {sup 10}B multi-grid proportional gas counters for large area thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, K. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Bigault, T. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Birch, J. [Linköping University, SE-581, 83 Linköping (Sweden); Buffet, J. C.; Correa, J. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Hall-Wilton, R. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Hultman, L. [Linköping University, SE-581, 83 Linköping (Sweden); Höglund, C. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Linköping University, SE-581, 83 Linköping (Sweden); Guérard, B., E-mail: guerard@ill.fr [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Jensen, J. [Linköping University, SE-581, 83 Linköping (Sweden); Khaplanov, A. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Kirstein, O. [Linköping University, SE-581, 83 Linköping (Sweden); Piscitelli, F.; Van Esch, P. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Vettier, C. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden)

    2013-08-21

    {sup 3}He was a popular material in neutrons detectors until its availability dropped drastically in 2008. The development of techniques based on alternative convertors is now of high priority for neutron research institutes. Thin films of {sup 10}B or {sup 10}B{sub 4}C have been used in gas proportional counters to detect neutrons, but until now, only for small or medium sensitive area. We present here the multi-grid design, introduced at the ILL and developed in collaboration with ESS for LAN (large area neutron) detectors. Typically thirty {sup 10}B{sub 4}C films of 1 μm thickness are used to convert neutrons into ionizing particles which are subsequently detected in a proportional gas counter. The principle and the fabrication of the multi-grid are described and some preliminary results obtained with a prototype of 200 cm×8 cm are reported; a detection efficiency of 48% has been measured at 2.5 Å with a monochromatic neutron beam line, showing the good potential of this new technique.

  8. Comprehensive applications of the gas flow proportional counters for radiological surveillance

    International Nuclear Information System (INIS)

    Babu, D.A.R.; Raman, Anand; Ashokkumar, P.; Sharma, D.N.

    2008-01-01

    Gas Flow Proportional Counters (GFPC) have been developed indigenously for various radiation protection applications. These detectors can be fabricated for 2 inches diameter filter paper sample counting applications to large area (∼1500 cm 2 ) detectors for surface contamination applications. Thin entrance windows allow non penetrating type of radiations like alpha and low energy beta particles, Efficiencies (for alpha and beta radiations) are comparable to conventional detectors used to measure these radiations. Poor gamma efficiency ( 2 /γ ratio, a high figure of merit and enables efficient gamma background rejection. These detectors are quite suitable for Indian environmental conditions. Three systems have been developed and successfully incorporated in to the radiation surveillance program at various nuclear facilities. The systems based on GFPC detectors include: a) Multiple sample gross alpha counting system; b) Laundry monitoring system; c) Alpha hand contamination monitoring system. The first of these enables simultaneous gross alpha counting of five air activity filter paper samples. The area of the detector surface is optimized to cover the 2 inches sized filter paper samples routinely used for the purpose. Five numbers of GFPC 's are arranged sequentially coupled to five individual amplifiers - micro controller modules to process the signal from the five counters. The laundry monitor which is micro controller based system consists of four large area multiwire GFPC detectors (700 cm 2 sensitive area) used to monitor alpha contamination of decontaminated laundry, Each detector uses a charge sensitive preamplifier coupled to I 2 C counter. The alpha hand monitoring system consists of four large area multiwire gas flow proportional detectors (330 cm 2 sensitive area each). A micro controller-based module is employed to initiate the counting process automatically when the hands are inserted in to the suitably designed window slots and provides audio and

  9. Radium 226 and uranium isotopes simultaneously determination in water samples using liquid scintillation counter

    International Nuclear Information System (INIS)

    Al-Masri, M.S.; Al-Akel, B.; Saaid, S.; Nashawati, A.

    2007-04-01

    In this work a method has been developed to determine simultaneously Radium 226 and Uranium isotopes in water samples by low back ground Liquid Scintillation Counter. Radium 226 was determined by its progeny Polonium 214 after one month of sample storage in order to achieve the equilibrium between Radium 226 and Polonium 214. Uranium isotopes were determined by subtracting Radium 226 activity from total alpha activity. The method detection limits were 0.049 Bq/L and 0.176 Bq/L for Radium 226 and Uranium isotopes respectively. The repeatability limits were ± 0.32 Bq/L and ± 0.9 Bq/L for Radium 226 and Uranium isotopes respectively. While relative errors were % 9.5 and %18.2 for Radium 226 and Uranium isotopes respectively. On the other hand, the report presented the results of different standard and natural samples.(author)

  10. Ultra Low Level Tritium Analysis Method Using a Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, S. J.; Kim, H. J.; Kim, H.; Lim, H. J.; Lee, M. W.; Jeong, D. H.; Kim, J. K.; Kang, Y. R. [Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, S. H. [Inje University, Gimhae, (Korea, Republic of)

    2015-05-15

    To evaluate {sup 3}H concentration in the atmosphere more accurately compared to the conventional methods, the author of this paper intended to suggest more improved analytical methods and derived the elements which might occur during analysis or required improvements. The method suggested in this study is able to reduce the uncertainty and errors which may be existent in evaluating the {sup 3}H concentration of environmental sample s and thus will serve as the best solution in the technical and economic point of view. Liquid Scintillation Counter is the most widely used to analyze ultra-low level {sup 3}H by using CPM / DPM Counting Mode using external radiation source and Spectrum Plot Mode using internal radiation source. In CPM / DPM Counting Mode, multiple samples can be measured by single calibration despite its rather higher background whereas Spectrum Plot Mode requires more time and cost to analyze multiple samples despite its reliability to reduce the contribution of other radionuclides.

  11. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Onuma, A.; Shimizu, M.; Chaya, K.; Hamamura, N. (Aichi Prefectural Inst. of Public Health, Nagoya (Japan)); Kagami, T.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method.

  12. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    International Nuclear Information System (INIS)

    Onuma, Akiko; Shimizu, Michihiko; Chaya, Kunio; Hamamura, Norikatsu; Kagami, Tadaaki.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method. (J.P.N.)

  13. Absolute determination of radiation bursts and of proportional counters space charge effect through the influence method

    International Nuclear Information System (INIS)

    Rios, I.J.; Mayer, R.E.

    2016-01-01

    When proportional counters are employed in charge integration mode to determine the magnitude of a radiation pulse, so intense that individual detection events take place in a time too short to produce individual output pulses, mostly in pulsed neutron sources, the strong build-up of positive space charge reduces the electric multiplication factor of the proportional detector. Under such conditions the ensuing measurement underestimates the amount of radiation that interacted with the detector. If the geometric characteristics, the filling gas pressure and the voltage applied to that detector are known, it becomes possible to apply an analytical correction method to the measurement. In this article we present a method that allows to determine the absolute value of the detected radiation burst without the need to know the characteristics of the employed detectors. It is necessary to employ more than one detector, taking advantage of the Influence Method. The “Influence Method” is conceived for the absolute determination of a nuclear particle flux in the absence of known detector efficiency and without the need to register coincidences of any kind. This method exploits the influence of the presence of one detector in the count rate of another detector, when they are placed one behind the other and define statistical estimators for the absolute number of incident particles and for the efficiency (Rios and Mayer, 2015 [1,2]). Its practical implementation in the measurement of a moderated neutron flux arising from an isotopic neutron source was exemplified in (Rios and Mayer, 2016 [3]) and the extension for multiple detectors in (Rios and Mayer 2016 [4]). - Highlights: • Absolute determination of radiation burst. • Proportional counters space charge effect. • Radiation measurements on pulsed devices.

  14. Scintillator counters with multi-pixel avalanche photodiode readout for the ND280 detector of the T2K experiment

    International Nuclear Information System (INIS)

    Mineev, O.; Afanasjev, A.; Bondarenko, G.; Golovin, V.; Gushchin, E.; Izmailov, A.; Khabibullin, M.; Khotjantsev, A.; Kudenko, Yu.; Kurimoto, Y.; Kutter, T.; Lubsandorzhiev, B.; Mayatski, V.; Musienko, Yu.; Nakaya, T.; Nobuhara, T.; Shaibonov, B.A.J.; Shaikhiev, A.; Taguchi, M.; Yershov, N.; Yokoyama, M.

    2007-01-01

    The Tokai-to-Kamioka (T2K) experiment is a second generation long baseline neutrino oscillation experiment which aims at a sensitive search for ν e appearance. The main design features of the T2K near neutrino detectors located at 280m from the target are presented, and the scintillator counters are described. The counters are readout via WLS fibers embedded into S-shaped grooves in the scintillator from both ends by multi-pixel avalanche photodiodes operating in a limited Geiger mode. Operating principles and results of tests of photosensors with a sensitive area of 1mm 2 are presented. A time resolution of 1.75ns, a spatial resolution of 9.9-12.4cm, and a detection efficiency for minimum ionizing particles of more than 99% were obtained for scintillator detectors in a beam test

  15. Scintillation counter and wire chamber front end modules for high energy physics experiments

    International Nuclear Information System (INIS)

    Baldin, Boris; DalMonte, Lou

    2011-01-01

    This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of ∼20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with ∼100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of ∼4 (micro)s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of ∼0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

  16. A liquid scintillation counter specifically designed for samples deposited on a flat matrix

    International Nuclear Information System (INIS)

    Potter, C.G.; Warner, G.T.

    1986-01-01

    A prototype liquid scintillation counter has been designed to count samples deposited as a 6x16 array on a flat matrix. Applications include the counting of labelled cells processed by a cell harvester from 96-well microtitration plates onto glass fibre filters and of DNA samples directly deposited onto nitrocellulose or nylon transfer membranes (e.g. 'Genescreen' NEN) for genetic studies by dot-blot hybridisation. The whole filter is placed in a bag with 4-12 ml of scintillant, sufficient to count all 96 samples. Nearest-neighbour intersample cross talk ranged from 0.004% for 3 H to 0.015% for 32 P. Background was 1.4 counts/min for glass fibre and 0.7 counts/min for 'Genescreen' in the 3 H channel: for 14 C the respective figures were 5.3 and 4.3 counts/min. Counting efficiency for 3 H-labelled cells on glass fibre was 54%(E 2 /B=2053) and 26% for tritiated thymidine spotted on 'Genescreen'(E 2 /B=980). Similar 14 C samples gave figures on 97%(E 2 /B=1775) and 81(E 2 B=1526) respectively. Electron emission counting from samples containing 125 I and 51 Cr was also possible. (U.K.)

  17. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  18. Dual-chamber/dual-anode proportional counter incorporating an intervening thin-foil solid neutron converter

    International Nuclear Information System (INIS)

    Boatner, Lynn A.; Neal, John S.; Blackston, Matthew A.; Kolopus, James A.; Ramey, Joanne O.

    2012-01-01

    A dual-chamber/dual-anode gas proportional counter utilizing thin solid 6 LiF or 10 B neutron converters coated on a 2-micon-thick Mylar film that is positioned between the two counter chambers and anodes has been designed, fabricated, and tested using a variety of fill gases—including naturally abundant helium. In this device, neutron conversion products emitted from both sides of the coated converter foil are detected—rather than having half of the products absorbed in the wall of a conventional tube-type counter where the solid neutron converter is deposited on the tube wall. Geant4-based radiation transport calculations were used to determine the optimum neutron converter coating thickness for both isotopes. Solution methods for applying these optimized-thickness coatings on a Mylar film were developed that were carried out at room temperature without any specialized equipment and that can be adapted to standard coating methods such as silk screen or ink jet printing. The performance characteristics of the dual-chamber/dual-anode neutron detector were determined for both types of isotopically enriched converters. The experimental performance of the 6 LiF-converter-based detector was described well by modeling results from Geant4. Additional modeling studies of multiple-foil/multiple-chamber/anode configurations addressed the basic issue of the relatively longer absorption range of neutrons versus the shorter range of the conversion products for 6 LiF and 10 B. Combined with the experimental results, these simulations indicate that a high-performance neutron detector can be realized in a single device through the application of these multiple-foil/solid converter, multiple-chamber detector concepts.

  19. An array of low-background 3He proportional counters for theSudbury Neutrino Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Amsbaugh, J.F.; Anaya, J.M.; Banar, J.; Bowles, T.J.; Browne,M.C.; Bullard, T.V.; Burritt, T.H.; Cox-Mobrand, G.A.; Dai, X.; H.Deng,X.; Di Marco, M.; Doe, P.J.; Dragowsky, M.R.; Duba, C.A.; Duncan, F.A.; Earle, E.D.; Elliott, S.R.; Esch, E.-I.; Fergani, H.; Formaggio, J.A.; Fowler, M.M.; Franklin, J.E.; Geissbuehler, P.; Germani, J.V.; Goldschmidt, A.; Guillian, E.; Hallin, A.L.; Harper, G.; Harvey, P.J.; Hazama, R.; Heeger, K.M.; Heise, J.; Hime, A.; Howe, M.A.; Huang, M.; Kormos, L.L.; Kraus, C.; Krauss, C.B.; Law, J.; Lawson, I.T.; Lesko,K.T.; Loach, J.C.; Majerus, S.; Manor, J.; McGee, S.; Miknaitis, K.K.S.; Miller, G.G.; Morissette, B.; Myers, A.; Oblath, N.S.; O' Kee, H.M.; Ollerhead, R.W.; Peeters, S.J.M.; Poon, A.W.P.; Prior, G.; Reitzner,S.D.; Rielage, K.; Robertson, R.G.H.; Skensved, P.; Smith, A.R.; Smith,M.W.E.; Steiger, T.D.; Stonehill,L.C.; Thornewell, P.M.; Tolich, N.; VanDevender, B.A.; VanWechel, T.D.; Wall, B.L.; Tseung, H.W.C.; Wendland,J.; West, N.; Wilhelmy, J.B.; Wilkerson, J.F.; Wouters, J.M.

    2007-02-01

    An array of Neutral-Current Detectors (NCDs) has been builtin order to make a unique measurement of the total active ux of solarneutrinos in the Sudbury Neutrino Observatory (SNO). Data in the thirdphase of the SNO experiment were collected between November 2004 andNovember 2006, after the NCD array was added to improve theneutral-current sensitivity of the SNO detector. This array consisted of36 strings of proportional counters lled with a mixture of 3He and CF4gas capable of detecting the neutrons liberated by the neutrino-deuteronneutral current reaction in the D2O, and four strings lled with a mixtureof 4He and CF4 gas for background measurements. The proportional counterdiameter is 5 cm. The total deployed array length was 398 m. The SNO NCDarray is the lowest-radioactivity large array of proportional countersever produced. This article describes the design, construction,deployment, and characterization of the NCD array, discusses theelectronics and data acquisition system, and considers event signaturesand backgrounds.

  20. Miniature proportional counter for compression measurements of laser-fusion targets

    International Nuclear Information System (INIS)

    Lane, S.M.; Dellis, J.H.; Bennett, C.K.; Campbell, E.M.

    1981-10-01

    Direct drive laser fusion targets consisting of DT gas encapsulated in glass microshells produce 14.1 MeV neutrons that can interact with silicon-28 nuclei in the glass to produce a 2.2 minute aluminum-28 activity. From the number of 28 Al nuclei created and the neutron yield, the compressed glass areal density can be found. To determine the number of activated atoms created, we collect approximately one-half of the target debris on a thin metal foil which is transferred to our beta-gamma coincidence detector. This detector consists of a 25 cm x 25 cm NaI(Tl) crystal having a 5 cm x 15 cm well. We have recently built a miniature proportional counter that fits into this well and is used to detect beta particles. It is constructed of .025 cm thick copper and has nine separate chambers through which methane flows. The coincidence background is 0.14 cpm and the measured beta efficiency is 45%. We are now building a .0125 cm thick counter made of aluminum having a predicted efficiency of > 90%

  1. Alpha–beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Wengrowicz, U.; Amidan, D. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2016-08-11

    A new approach for a simultaneous alpha–beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha–beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha–beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  2. Development of a parallel plate proportional counter TRD with suppressed sensitivity to ionization

    International Nuclear Information System (INIS)

    Solomey, N.; Krolak, P.; Graham, G.

    1995-01-01

    The development of a Parallel Plate Proportional Counter which has a highly suppressed sensitivity to ionization but retains a good X-ray signal to noise ratio is presented. Details of the laboratory development and actual beam tests showing the e/π rejection are described. Because of its insensitivity to ionization this type of detector can be useful in an environment where the number of minimum ionizing particles are high, but uninteresting; however, the detector is very sensitive to the highly localized electron cloud from converted X-rays making it ideal as a transition radiation X-ray detector. Thus, this detector only gives a signal for charged particles above TR threshold; all other particles below this threshold produce no TR X-rays giving only a pedestal-like signal. The system's potential performance for π/p separation in the intended neutral Hyperon experiment is evaluated

  3. Radiation effects on the proportional counter X-ray detectors on board the NEAR spacecraft

    International Nuclear Information System (INIS)

    Floyd, S.R.; Trombka, J.I.; Leidecker, H.W.; Clark, P.E.; Starr, R.; Goldsten, J.O.; Roth, D.R.

    1999-01-01

    The X-ray proportional counters on board the Near Earth Asteroid Rendezvous (NEAR) spacecraft have exhibited a resolution degradation and recovery phenomenon several times during the long cruise phase of the mission. The resolution is checked periodically by commanding an 55 Fe source into the window area. The degradation is seen as a low energy tailing of the 5.9 keV photopeak. Two events have occurred which provided good spectral data for better understanding the degradation phenomenon. In November 1997 a large solar particle event occurred that degraded the resolution and excited copper in the collimator. Eventually the detectors returned to normal. In January 1998 the spacecraft performed an Earth swingby gravity assist maneuver. The near Earth environment excited the magnesium and aluminum in the filter elements. The copper line was also produced. The NEAR spacecraft was launched in February 1996 and will rendezvous and orbit the asteroid 433 Eros in early 1999

  4. Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

    Directory of Open Access Journals (Sweden)

    Uk-Won Nam

    2013-06-01

    Full Text Available Tissue equivalent proportional counter (TEPC can measure the Linear Energy Transfer (LET spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS. The prototype TEPC which can simulate a 2 μm of the site diameter for micro-dosimetry has been tested with a standard alpha source (241Am, 5.5 MeV. Also, the calibration of the TEPC was performed by the 252Cf neutron standard source in Korea Research Institute of Standards and Science (KRISS. The determined calibration factor was kf = 3.59×10-7 mSv/R.

  5. KEhD-1 Debye-Sherrar camera with a coordinate proportional counter

    International Nuclear Information System (INIS)

    Ageev, O.I.; Glazova, L.P.; Goganov, D.A.; Rejzis, B.M.; Syrkin, M.G.

    1985-01-01

    An arrangement of the KEhD-1 Debye-Sherrar camera, in which the advantages of a proportional counter are combined with the wide range of simultaneous image recording is described. The camera consists of an X-ray tube unit with the URS-0.1 source, a linear coordinate detector with resistive-capacity coding, a signal transducer and the MK-1 multichannel system for data acquisition and processing based on the ''Uskra-1256'' computer. The counting rate of X-ray pulses is > 5x10 4 s -1 , energy resolution for the CuKsub(α) line constitutes 20%, spatial resolution equals 150 μm, detection efficiency constitutes not less than 64%. The range of the detector displacement varies from -30 deg to +130 deg. The information obtained by means of the camera may be output to a display, a plotter, a numeric printer or a magnetic tape

  6. Background simulation for the Spherical Proportional Counter and its use for the detection of optical photons

    International Nuclear Information System (INIS)

    Bougamont, E; Colas, P; Dastgheibi-Fard, A; Derre, J; Giomataris, I; Gerbier, G; Gros, M; Magnier, P; Navick, X F; Tsiledakis, G; Salin, P; Savvidis, I; Vergados, J D

    2013-01-01

    The recently developed Spherical Proportional Counter [1] allows to instrument large target masses with good energy resolution and sub-keV energy threshold. The moderate cost of this detector, its simplicity and robustness, makes this technology a promising approach for many domains of physics and applications, like dark matter detection and low energy neutrino searches. Detailed Monte Carlo simulations are essential to evaluate the background level expected at the sub-keV energy regime. The simulated background here, it refers to the contribution of the construction material of the detector and the effect of the environmental gamma radiation. This detector due to its spherical shape could be also served as an optical photon detector provided it is equipped with PMTs, for Double Beta decay and Dark Matter searches. All calculations shown here are obtained using the FLUKA Monte Carlo code

  7. A powerful, low-cost histogramming memory for digital radiography with multi-wire proportional counters

    International Nuclear Information System (INIS)

    Bateman, J.E.; Locke, C.E.R.; Ferrari, C.A.

    1986-01-01

    A powerful, low-cost histogramming memory for digital radiograph with multi-wire proportional counter is described. The memory is based on a commercial video display device coupled to an Apple II microcomputer which, at a total cost of around 2500 pounds gives a system with 512 x 512 pixel resolution and a counting range of 4095 counts per pixel. The system can take data at rates of up to 5000 Hz while providing a live-time display. No hardware modifications are necessary, the comprehensive storage and display facilities being implemented in a combined package of BASIC and ASSEMBLER software. An ACCELERATOR coprocessor card is used to enhance the performance of the system. (author)

  8. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter)

    International Nuclear Information System (INIS)

    2013-01-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  9. Imaging micro-well proportional counters fabricated with masked UV laser ablation

    CERN Document Server

    Deines-Jones, P; Crawford, H; Hunter, S D

    2002-01-01

    The micro-well detector is a gas-proportional counter similar to the CAT (Bartol et al., J. Phys. III 6 (1996) 337) and WELL detectors (Bellazzini et al., Nucl. Instr. and Meth. A 423 (1999) 125). The micro-well is a cylindrical hole formed in the polymer substrate of commercially fabricated copper-clad flexible printed circuit board by UV laser ablation. The micro-wells are drilled at GSFC's UV laser-ablation facility. The cathode is a metal annulus that surrounds the opening of the well. The anode is a metal pad that fills the bottom of the well. Advantages of this topology include intrinsic two-dimensional sensing, thick robust electrodes, and large localized image charge on the cathodes. We have fabricated 5 cmx5 cm micro-well detectors with segmented anodes (1-d) and with both anodes and cathodes segmented (2-d), and have demonstrated: - stable, proportional operation at gas gains in excess of 30,000 in Ar- and Xe-based gases; - FWHM energy resolution of 20% at 6 keV in P-10; - preliminary 1-d spatial re...

  10. Single channel analog pulse processor Asic for gas proportional counters and SI detector

    International Nuclear Information System (INIS)

    Chandratre, V.B.; Sarkar, Soumen; Kataria, S.K.; Viyogi, Y.P.

    2005-01-01

    The paper presents the design and development of a single channel pulse processor in short Singleplex ASIC targeted for gas proportional counters/Si detectors. The design is optimized for the dynamic range of +500 fC to -500 fC with provision for externally adjusted pole-zero cancellation. A dedicated filter based on the de-convolution principle is used for the cancellation of the long hyperbolic signal tail produced by the slow drift of ions, typical in gas proportional with the filter time constants derived from the actual detector input signal shape. The pole-zero adjustment can be done by external dc voltage to achieve perfect base-line recovery to 1% after 5 μs. The simulated 0 pf noise is 500 e - rms for the peaking time of 1.2 μs with noise slope of 7e - -. The gain is 3.4 mv/fC over the entire linear dynamic range with power dissipation of 13 mW. This design is a modified version of Indiplex chip with features dynamic range equal gain on both polarities with nearly same noise and serves as diagnostic chip for Indiplex. The chip can be used for radiation monitoring instruments. (author)

  11. Photon and neutron dose discrimination using low pressure proportional counters with graphite and A150 walls

    International Nuclear Information System (INIS)

    Kylloenen, J.; Lindborg, L.

    2005-01-01

    Full text: The determination of both the low- and high-LET components of ambient dose equivalent in mixed fields is possible with microdosimetric methods. With the multiple-event microdosimetric variance covariance method the sum of those components are directly obtained also in pulsed beams. However, if the value of each dose component is needed a more extended analysis is required. The use of a graphite walled proportional detector in combination with a tissue-equivalent proportional counter in combination with the variance covariance method was here investigated. MCNP simulations were carried out for relevant energies to investigate the photon and neutron responses of the two detectors. The combined graphite and TEPC system, the Sievert instrument, was used for measurements at IRSN, Cadarache, in the workplace calibration fields of CANEL+, SIGMA, a Cf-252 and a moderated Cf(D 2 O,Cd) radiation field. The response of the instrument in various monoenergetic neutron fields is also known from measurements at PTB. The instrument took part in the measurement campaigns in workplace fields in the nuclear industry organized within the EVIDOS contract. The results are analyzed and the method of using a graphite detector compared with alternative methods of analysis is discussed. (author)

  12. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  13. Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

    Science.gov (United States)

    Sunil, C.; Tyagi, Mohit; Biju, K.; Shanbhag, A. A.; Bandyopadhyay, T.

    2015-12-01

    The scarcity and the high cost of 3He has spurred the use of various detectors for neutron monitoring. A new lithium yttrium borate scintillator developed in BARC has been studied for its use in a neutron rem counter. The scintillator is made of natural lithium and boron, and the yield of reaction products that will generate a signal in a real time detector has been studied by FLUKA Monte Carlo radiation transport code. A 2 cm lead introduced to enhance the gamma rejection shows no appreciable change in the shape of the fluence response or in the yield of reaction products. The fluence response when normalized at the average energy of an Am-Be neutron source shows promise of being used as rem counter.

  14. Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

    Energy Technology Data Exchange (ETDEWEB)

    Sunil, C., E-mail: csunil11@gmail.com [Accelerator Radiation Safety Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Tyagi, Mohit [Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Biju, K.; Shanbhag, A.A.; Bandyopadhyay, T. [Accelerator Radiation Safety Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2015-12-11

    The scarcity and the high cost of {sup 3}He has spurred the use of various detectors for neutron monitoring. A new lithium yttrium borate scintillator developed in BARC has been studied for its use in a neutron rem counter. The scintillator is made of natural lithium and boron, and the yield of reaction products that will generate a signal in a real time detector has been studied by FLUKA Monte Carlo radiation transport code. A 2 cm lead introduced to enhance the gamma rejection shows no appreciable change in the shape of the fluence response or in the yield of reaction products. The fluence response when normalized at the average energy of an Am–Be neutron source shows promise of being used as rem counter.

  15. Application of digital waveform processing to position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Takenaka, Yasuto; Uritani, Akira; Mori, Chizuo

    1995-01-01

    In a charge-division type position-sensitive proportional counter (PSPC) with an anode wire of small resistance, a reflected component from an opposite end and thermal noise involved in signals deteriorate the position resolution of the PSPC. A digital waveform processing method was applied to the reduction of these undesirable effects by skillfully utilizing their signal characteristics that can be observed as inversely correlative signals between two-output signals from both sides of the PSPC. The digital waveform processing could improve the position resolution compared to a conventional pulse height processing method with analog filters. When the digital waveform processing was applied to signals of an equivalent circuit simulating the PSPC, the position resolutions defined by the full width at half maximum were improved to about 30% of those of conventional analog pulse processing. In the case of an actual PSPC, the position resolutions by the digital waveform processing were improved by 4-10% as compared with those of conventional pulse height processing. (author)

  16. Controlling low-rate signal path microdischarge for an ultra-low-background proportional counter

    International Nuclear Information System (INIS)

    Mace, E.K.; Aalseth, C.E.; Bonicalzi, R.M.; Day, A.R.; Hoppe, E.W.; Keillor, M.E.; Myers, A.W.; Overman, C.T.; Seifert, A.

    2013-01-01

    Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ∼30 m water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ∼1 m of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors. (author)

  17. Preliminary results from a high-pressure imaging spectroscopic proportional counter

    International Nuclear Information System (INIS)

    Hall, C.J.; Bazzano, A.; Lewis, R.A.; Parker, B.; Ubertini, P.; Worgan, J.S.

    1992-01-01

    A new type of high-pressure proportional counter, with both spatial resolution and spectroscopic capabilities is being jointly developed by the Istituto di Astrofisica Spaziale (CNR), Frascati, Italy and the SERC Daresbury Laboratory, Warrington, UK. The characteristics of the detector can be optimized for the particular requirement of the experiment, either for x-ray astronomy observations from space, or for the high count rate applications associated with a synchrotron light source. In its baseline configuration, the detector is filled to 5 bar with a xenon/quench gas mixture and will be sensitive over the energy range 5 keV to 150 keV (2.5 to 0.08 A). The positional resolution will range from 500 μm at the lower energies to around 1 mm at the higher end of the energy range. The current prototype has a sensitive area of 200x200 mm. The final version is hoped to have an area closer to 425x425 mm. The very small photon absorption length in the higher pressure gas allows the parallax effect, a feature of 1 atmosphere detectors, to be greatly reduced. The timing resolution (150 ns) of the detector enables both a high-rate capability and the possibility of the escape gate technique to achieve higher spectral resolution at energies > the Xe K edge. Preliminary results are presented showing the spectral and positional resolution for the prototype detector

  18. The Rutherford Appleton Laboratory's Mark I multiwire proportional counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1984-01-01

    A small (30 cmx30 cm) model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on multiwire proportional counter technology, it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. This has permitted evaluation of this type of positron imaging system in the clinical environment using both cyclotron generated isotopes ( 15 O, 11 C, 18 F, 124 I) and available isotopic generator systems ( 82 Rb, 68 Ga). AT RAL we provided a complete hardware system and sufficient software to permit our hospital based colleagues to generate useful images with the minimum of effort. A complete description of the system is given with performance figures and some of the images obtained in three hospital visits are presented. Some detailed studies of the imaging performance of the positron camera are reported which have bearing on the design of future, improved systems. (orig.)

  19. Helium-filled proportional counter and its operation mechanism at low temperatures

    CERN Document Server

    Isozumi, Y; Kishimoto, S

    2002-01-01

    The operation mechanism of helium-filled proportional counter (HFPC) at about 4.2 K is explained. Unstable behavior of HFPC is caused by releasing secondary-electron from the cathode by four kinds of active particles such as He sub n sup + , non-resonance photon from excited helium atom, non-resonance photon from He sub 2 sup * (A sup 1 Su sup +) and He sub 2 sup m (a sup 3 Su sup +). On experiments of HFPC behavior at low temperature, the following facts were observed; 1) main charge formation process in the electron avalanche is direct ionization by electron without Hornbeck-Molnar process. Accordingly, the gas amplification factor becomes small at low temperature. 2) Stable helium cation is He sub 2 sup + at room temperature, but cluster at low temperature. Large after-pulse is observed in output signal depends on cluster ion. The probability of secondary-electron emission decreased. The gas gain increased with increasing anode voltage. 3) By decreasing reaction rate of atom and molecule collision at low t...

  20. MCNP modelling of the wall effects observed in tissue-equivalent proportional counters.

    Science.gov (United States)

    Hoff, J L; Townsend, L W

    2002-01-01

    Tissue-equivalent proportional counters (TEPCs) utilise tissue-equivalent materials to depict homogeneous microscopic volumes of human tissue. Although both the walls and gas simulate the same medium, they respond to radiation differently. Density differences between the two materials cause distortions, or wall effects, in measurements, with the most dominant effect caused by delta rays. This study uses a Monte Carlo transport code, MCNP, to simulate the transport of secondary electrons within a TEPC. The Rudd model, a singly differential cross section with no dependence on electron direction, is used to describe the energy spectrum obtained by the impact of two iron beams on water. Based on the models used in this study, a wall-less TEPC had a higher lineal energy (keV.micron-1) as a function of impact parameter than a solid-wall TEPC for the iron beams under consideration. An important conclusion of this study is that MCNP has the ability to model the wall effects observed in TEPCs.

  1. Simulated Response of a Tissue-equivalent Proportional Counter on the Surface of Mars.

    Science.gov (United States)

    Northum, Jeremy D; Guetersloh, Stephen B; Braby, Leslie A; Ford, John R

    2015-10-01

    Uncertainties persist regarding the assessment of the carcinogenic risk associated with galactic cosmic ray (GCR) exposure during a mission to Mars. The GCR spectrum peaks in the range of 300(-1) MeV n to 700 MeV n(-1) and is comprised of elemental ions from H to Ni. While Fe ions represent only 0.03% of the GCR spectrum in terms of particle abundance, they are responsible for nearly 30% of the dose equivalent in free space. Because of this, radiation biology studies focusing on understanding the biological effects of GCR exposure generally use Fe ions. Acting as a thin shield, the Martian atmosphere alters the GCR spectrum in a manner that significantly reduces the importance of Fe ions. Additionally, albedo particles emanating from the regolith complicate the radiation environment. The present study uses the Monte Carlo code FLUKA to simulate the response of a tissue-equivalent proportional counter on the surface of Mars to produce dosimetry quantities and microdosimetry distributions. The dose equivalent rate on the surface of Mars was found to be 0.18 Sv y(-1) with an average quality factor of 2.9 and a dose mean lineal energy of 18.4 keV μm(-1). Additionally, albedo neutrons were found to account for 25% of the dose equivalent. It is anticipated that these data will provide relevant starting points for use in future risk assessment and mission planning studies.

  2. Recent improvements to RC-line encoded position-sensitive proportional counters

    International Nuclear Information System (INIS)

    Borkowski, C.J.; Kopp, M.K.

    1977-01-01

    Continuing research on the principles of position encoding with RC lines has advanced the design of position-sensitive proportional counters (PSPCs) to meet the requirements for high count rates (>10 5 counts/sec) and good spatial resolution (>10 4 spatial elements) in small-angle scattering experiments with x rays and neutrons. Low-noise preamplifiers were developed with pole-zero cancellation in the feedback circuit and modular linear amplifiers with passive RCL shaping which, compared to previous designs, reduce output saturation at high count rates approx.20 times and shorten the position signal processing time to 2 ) for low-energy ( 800 x 800 mm 2 ) for the measurement of small-angle scattering with neutrons. The method of electronic thickness discrimination was applied to change the effective thickness of an area PSPC from 12 to 2 cm whenever the molybdenum target of an x-ray generator was changed to a copper target. This thickness adjustment increased the signal-to-background ratio by a factor of approx.6 for the 8-keV photons from the copper target, while maintaining a >90% detection efficiency

  3. A suspended boron foil multi-wire proportional counter neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Kyle A.; Edwards, Nathaniel S.; Hinson, Niklas J.; Wayant, Clayton D.; McGregor, Douglas S.

    2014-12-11

    Three natural boron foils, approximately 1.0 cm in diameter and 1.0 µm thick, were obtained from The Lebow Company and suspended in a multi-wire proportional counter. Suspending the B foils allowed the alpha particle and Li ion reaction products to escape simultaneously, one on each side of the foil, and be measured concurrently in the gas volume. The thermal neutron response pulse-height spectrum was obtained and two obvious peaks appear from the 94% and 6% branches of the {sup 10}B(n,α){sup 7}Li neutron reaction. Scanning electron microscope images were collected to obtain the exact B foil thicknesses and MCNP6 simulations were completed for those same B thicknesses. Pulse-height spectra obtained from the simulations were compared to experimental data and matched well. The theoretical intrinsic thermal–neutron detection efficiency for enriched {sup 10}B foils was calculated and is presented. Additionally, the intrinsic thermal neutron detection efficiency of the three natural B foils was calculated to be 3.2±0.2%.

  4. A suspended boron foil multi-wire proportional counter neutron detector

    Science.gov (United States)

    Nelson, Kyle A.; Edwards, Nathaniel S.; Hinson, Niklas J.; Wayant, Clayton D.; McGregor, Douglas S.

    2014-12-01

    Three natural boron foils, approximately 1.0 cm in diameter and 1.0 μm thick, were obtained from The Lebow Company and suspended in a multi-wire proportional counter. Suspending the B foils allowed the alpha particle and Li ion reaction products to escape simultaneously, one on each side of the foil, and be measured concurrently in the gas volume. The thermal neutron response pulse-height spectrum was obtained and two obvious peaks appear from the 94% and 6% branches of the 10B(n,α)7Li neutron reaction. Scanning electron microscope images were collected to obtain the exact B foil thicknesses and MCNP6 simulations were completed for those same B thicknesses. Pulse-height spectra obtained from the simulations were compared to experimental data and matched well. The theoretical intrinsic thermal-neutron detection efficiency for enriched 10B foils was calculated and is presented. Additionally, the intrinsic thermal neutron detection efficiency of the three natural B foils was calculated to be 3.2±0.2%.

  5. Design of a hybrid gas proportional counter with CdTe guard counters for sup 1 sup 4 C dating system

    CERN Document Server

    Zhang, L; Hinamoto, N; Nakazawa, M; Yoshida, K

    2002-01-01

    Nowadays uniform, low-cost and large-size compound semiconductor detectors are available up to several square centimeters. We are trying to combine this technology with conventional gas detectors to upgrade an anticoincidence type proportional counter, Oeschger-type thin wall counter of 2.2 l, used for a sup 1 sup 4 C dating facility at the University of Tokyo. In order to increase the ratio of the signal to the background for smaller quantity of samples less than 1 g, an effective approach is to minimize the detector volume at higher gas pressure. However, the anticoincidence function suffers from such a small volume. Therefore we designed a new active wall gas counter of 0.13 l counting volume using CdTe compound semiconductor detectors as the wall of the gas proportional counter to perform anticoincidence. Simulation study showed that at noise thresholds less than 70 keV, the wall counters can reject above 99.8% of events arising from outer gamma rays. Measured noise levels of CdTe detectors were smaller t...

  6. Measuring variation of indoor radon concentration using bare nuclear tracks detectors, scintillation counters and surface barrier detectors

    International Nuclear Information System (INIS)

    Ishak, I.; Mahat, R.H.; Amin, Y.M.

    1996-01-01

    Bare LRI 15 nuclear track detectors , scintillators counter and surface barrier detectors were used to measured the indoor radon concentration in various location within two rooms. Spatial variation of the radon concentration is caused by positioning of the door, windows, furniture, cracks in the building and also distances from floor, wall and ceiling. It is found that the change in temperature are causing radon concentration to increase at certain time of the day

  7. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  8. Determination of the air/water partition coefficient of groundwater radon using liquid scintillation counter

    International Nuclear Information System (INIS)

    Lee, K.Y.; Yoon, Y.Y.; Ko, K.S.

    2010-01-01

    A method was studied for measuring air/water partition coefficient (K air/water ) of groundwater radon by a simple procedure using liquid scintillation counter (LSC). In contrast conventional techniques such as equilibrium partitioning in a closed system or air striping methods, the described method allow for a simple and uncomplicated determination of the coefficient. The (K air/water ) of radon in pure water has been well known quantitatively over a wide range of temperatures. In this work, groundwater samples having high radon concentration instead of distilled water have been used to determine the (K air/water ) of radon in the temperature range of 0-25. Aqueous phase in a closed system was used in this study instead of gaseous phase in conventional methods. Three kinds of groundwater taken from different geologic environments were used to investigate the effect of groundwater properties. With the aim to evaluate the reproducibility of the data an appropriate number of laboratory experiments have been carried out. The results show that tie (K air/water ) of radon in the groundwater is smaller than that in the pure water. However, the temperature effect on the coefficient is similar in the groundwater and the pure water. The method using aqueous phase in a closed system by LSC can be used to determine the (K air/water ) of radon in various groundwaters with a simple procedure. The results will be presented at the NAC-IV conference

  9. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  10. Methods of calculus for neutron spectrometry in proportional counters; Metodos de calculo para espectrometria de neutrones en contadores proporcionales

    Energy Technology Data Exchange (ETDEWEB)

    Butragueno, J L; Blazquez, J B; Barrado, J M

    1976-07-01

    Response functions for cylindrical proportional counters with hydrogenated gases have been determined, taking in account only wall effect, by means of two independent calculus methods. One of them is a Monte Carlo application and the other one analytica at all. Results of both methods have been compared. (Author)

  11. Interfacing a gas proportional counter with a mass spectrometer: Simultaneous display of GC/MS and radiocarbon data

    International Nuclear Information System (INIS)

    Peterson, G.S.; Laemmerhirt, D.F.; Weaver, A.

    1985-01-01

    To facilitate the location of pesticides and monitor their metabolism in environmental and biological systems, carbon-14 labelling of the parent compound is used. Detection of the radiolabel is achieved using a gas proportional counter, while identification of the labelled components is most easily accomplished with mass spectrometry. However, when these two operations are performed separately, correlation of the information is awkward, at best. Since each is a destructive detector, simultaneous monitoring of the outposts requires an effluent splitter. The complete system consists of a variable splitter, which allows control of the ratio of the GC effluent to the two instruments, and signal processing circuitry for simultaneous recording and storage of radiocarbon and mass spectral data. Modifications to a Finnigan GC/MS and Gas Proportional Counter included a high temperature GC effluent splitter with glass-lined connecting tubing, and a data interface, including analog to digital and serial to parallel conversions with optical isolation between the gas proportional counter and the computer. The splitter restricted the flow to the mass spectrometer, preventing flow completely in the closed position. The split was adjusted to maximize flow to the mass spectrometer using the vacuum as a rough guide (1.0 x 10 -5 torr in EI, 7.5 x 10 -5 torr in CI). A heated transfer line between the transfer oven and gas proportional counter prevented condensation of eluting components prior to radiocarbon detection

  12. Design and construction techniques for one-meter position sensitive proportional counters of the helical delay line type

    International Nuclear Information System (INIS)

    Orbesen, S.D.; Sherman, J.D.; Flynn, E.R.

    1976-03-01

    A description is given of the techniques involved in the construction of a one-meter long helical proportional counter which produces excellent position accuracy of 1 mm while yielding particle identification through a measurement of energy loss and total energy

  13. Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy

    Czech Academy of Sciences Publication Activity Database

    Farah, J.; De Saint-Hubert, M.; Mojzeszek, N.; Chiriotti, S.; Gryzinski, M.; Ploc, Ondřej; Trompier, F.; Turek, Karel; Vanhavere, F.; Olko, P.

    2017-01-01

    Roč. 96, JAN (2017), s. 42-52 ISSN 1350-4487 EU Projects: European Commission(XE) 662287 - CONCERT Institutional support: RVO:61389005 Keywords : tissue-equivalent proportional counters * microdosimetry * proton therapy * stray neutrons and prothons Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.442, year: 2016

  14. Response of a carbon-walled proportional counter to 14 MeV neutrons

    International Nuclear Information System (INIS)

    Lewis, K.D.

    1982-01-01

    The response of a carbon-walled spherical proportional counter filled with a methane-based tissue-equivalent gas mixture at low pressure and irradiated with 14 MeV neutrons is first measured experimentally and is then calculated theoretically by using an analytical model. The model, called the CISS model, is derived from a consideration of four basic modes of interaction of charged particles generated in neutron-nucleus reactions with the spherical cavity of the detector. Since several quantities which have application in neutron dosimetry, radiation protection, and radiation biology make direct use of such spectra, it is desirable to have the ability to theoretically predict what is expected experimentally. Thus, a comparison between the two response curves is made. The discrepancy between them is investigated by considering several physical phenomena occurring within the detector wall which tend to distort the experimental response curve. In particular, the C(n,n',3α) reaction occurring in the detector wall gives rise to multiple events, originating from a single neutron interaction in the wall simultaneously strike the detector cavity, and are recorded as a single larger event in an experimental spectra. In the analytic model, the simultaneous entry of two charged particles into the cavity is scored as two separate smaller events, uncorrelated in their production. In this work, an effort is made to modify the analytic model prediction of the response curve by correcting for the multiple events which occur. Finally, the CISS model is used to compute mass stopping power corrections for this inhomogeneous detector

  15. Present development of scintillator counters in France; Etat actuel du developpement des compteurs a scintillation en France

    Energy Technology Data Exchange (ETDEWEB)

    Koechlin, Y; Koch, L; Lansiart, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Pietri, G [Laboratoire d' Electronique et de Physique Appliquee (France)

    1958-07-01

    For a number of years photomultipliers and scintillators have been produced on an industrial scale in France. The AEC has accepted the task of testing their performance, and advising the industry in consequence. This combined effort has resulted in the wide range of photomultipliers and scintillators summarised in the following paper. (author)Fren. [French] La france fabrique industriellement depuis quelques annees des photomultiplicateurs et des scintillateurs. Le Commissariat a l'Energie atomique s'est charge de mesurer leurs performances et de conseiller l'industrie fran ise a ce sujet. C'est ainsi que nous disposons actuellement de toute une gamme de photomultiplicateurs et de scintillateurs fran is dont nous donnons ci-dessous un apercu. (auteur)

  16. Method for calibration measurement in a liquid scintillation counter and carrier used in the method

    International Nuclear Information System (INIS)

    Reunanen, M.A.

    1976-01-01

    The present invention relates to a method for use in liquid scintillation measurements to feed an accurately determined amount of radioactive substance to a fluid scintillation system for a calibration measurement. According to the invention an accurately determined amount of radioactive substance is adsorbed to a carrier, which is introduced into the fluid scintillation system. The invention also relates to a carrier for use in the method

  17. The Proportional Counter. Some Aspects of Operation; Le compteur proportionnel. Ses caracteristiques de fonctionnement; Proportsional'nyj schetchik. Nekotorye aspekty raboty; El contador proportional. Sus caracteristicas de funcionamiento

    Energy Technology Data Exchange (ETDEWEB)

    Curran, S C [Awre, Aldermaston (United Kingdom)

    1960-06-15

    1. Work on a counter system designed for electron capture studies has shown that the diameter of the anode wire in a high-pressure proportional counter can have an important influence on the energy resolution obtained in measurements of low-energy radiations. In a counter working at a pressure of 12 atmospheres the width of the pulse distribution due to 13.5 keV K-capture radiations could be changed from 65% to 17% by changing the wire diameter from 0.0076 mm to 0.0025 mm. This phenomenon is interpreted as an effect of positive ion space charge in the avalanche. For a given gas gain and primary radiation the density of positive ions in the avalanche increases rapidly with pressure of the filling gas, and when the accompanying electric fields are large enough to affect the last stages of the multiplication process the energy resolution of the counter deteriorates. Decrease in diameter of the anode wire increases the externally applied field in the region where multiplication takes place, thus tending to counteract the effect of space charge. Use of 0.0025 mm anode wires has proved satisfactory in new measurements of L/K capture ratios made with a multiwire counter system working at pressures up to 12 atmospheres. The results obtained for L/K capture ratios of Ge{sup 71} and Kr{sup 79} are 0.115 and 0.112 respectively. The same counting system has also been used in a search for M capture in these two isotopes. The low energy of the M capture radiation, 180 eV in Ge{sup 71} and 260 eV in Kr{sup 79}, and its low intensity relative to that of K capture, makes accurate measurement difficult; but peaks attributable to M capture were observed in pulse spectra of both sources. 2. Low-Background Counting - Recent observations made on a combination of proportional counter and scintillation counters (operating as shields) show that there are some real difficulties in devising a relatively simple system of this kind. The performance is inherently very satisfactory but practical

  18. Scintillators

    International Nuclear Information System (INIS)

    Cusano, D.A.; Holub, F.F.; Prochazka, S.

    1979-01-01

    Scintillator bodies comprising phosphor materials and having high optical translucency with low light absorption, and methods of making the scintillator bodies, are described. Fabrication methods include (a) a hot-pressing process, (b) cold-pressing followed by sintering, (c) controlled cooling from a melt, and (d) hot-forging. The scintillator bodies that result are easily machined to desired shapes and sizes. Suitable phosphors include BaFCl:Eu, LaOBr:Tb, CsI:Tl, CaWO 4 and CdWO 4 . (U.K.)

  19. Numerical determination of the amplification of a cylindrical proportional counter operating at low pressure. Application to nano-dosimetry

    International Nuclear Information System (INIS)

    Moutarde, Cyrille

    1994-01-01

    This work is devoted to a study of proportional counters used to measure the energy deposition in micrometer biological sites. Tissue equivalent gas filling improve typical operating mode of those counters. Specially, the extension of the multiplication zone becomes important at low pressures. A Monte Carlo simulation has been used to study the behaviour of an electron swarm in the sensitive volume. The calculations show that electrons are not in equilibrium with the applied electric field in this geometry. The influence of the gradient field and the rotation of the electrons around the anode wire has been studied carefully. The importance of non-equilibrium effects on the theoretical amplification calculated through the ionisation coefficient has been confirmed by experimental investigations. The statistical fluctuations of multiplication process has been calculated by the determination of avalanche spectra at the anode. Resolution of an ultra-miniature counter have been calculated to improve technological limitations of experimental nanodosimetry. (author) [fr

  20. TOPAS 1 - construction and test of a scintillation counter hodoscope for the tagging of bremsstrahlung photons for the SAPHIR detector

    International Nuclear Information System (INIS)

    Merkel, R.

    1989-09-01

    The development of a tagging-hodoscope for the SAPHIR-detector at the stretcher ring ELSA in Bonn is described. The hodoscope covers the energy range 2.175 GeV γ 0 =3.500 GeV. 24 scintillation counters are used for the determination of the photon energy, giving a resolution of ΔE γ =25 MeV. The tagging method requires a good coincidence timing resoluting τ between the tagging hodoscope and the detector for the photon-induced reactions in order to keep the accidental coincidences low. The timing information is given by 8 fast timing counters (40 mm thick), covering 5 up to 7 energy channels each. Fluctuations of the timing signal which result from different impact-locations on the timing counter, due to different light travelling distances, are corrected by the energy defining counters. The timing-component (8 timing counters) is commpleted and tested. The results of first mesurements show an upper limit of σ=250 psec for the resolution of 7 coincidences out of 45 possible channels in the tagging hodscope. These results are obtained with a preliminary adjustment of the SAPHIR beam-line and with a not yet optimized signal to noize ratio in the extracted beam. We hope to obtain a σ<200 psec under optimized conditions. (orig.)

  1. Use of proportional gas scintillator in absolute measurements of alpha-gamma emitter activities

    International Nuclear Information System (INIS)

    Tobias, C.C.B.

    1987-01-01

    The absolute activity of U-235 contained in a U 3 O 8 sample was measured utilizing a sum-coincidence circuit which selects only the alpha particles which are simultaneous with the 143 KeV and 186 KeV gamma radiations from the Th-231 (product nucleus). The alpha particles were detected by means of a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas atoms, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. The gamma radiations were detected by means of a NaI(Tl) 1'' x 1 1/2'' scintillation detector. The value obtained for the half-life of U-235 was compared with the data available from various observers which used different experimental techniques. It is shown tht the results, are in excellent agreement with the best international data available on the subject and that, therefore, the sum-coincidence technique constitutes an important method for such measurements. (Author) [pt

  2. Characteristics of proportional counters used in X-ray radiometric analysis

    International Nuclear Information System (INIS)

    Mamikonyan, S.V.; Martishchenko, L.G.; Mel'ttser, L.V.

    1972-01-01

    Counters with extended (up to 10 cm 2 ) apertres have been described and the results obtained are presented. CPM-15 and CPM-16 counters are intended for sensoring and spectral analysis of X-rays in the range of 2.5 to 23 and 2.5 to 15 keV, respectively. The only difference is in the gas composition. The CPM-15 counter is filled with 90 per cent xenon plus 10 per cent methane used as a quenching dopant. The CPM-16 is filled with 90 per cent argon and 10 per cent methane. The life time is 10 10 pulses at 1800 V for CPM-16 and at 2200 V for CPM-15

  3. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  4. A technique for searching for the 2 K capture in 124Xe with a copper proportional counter

    Science.gov (United States)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V.; Panasenko, S. I.; Ratkevich, S. S.; Tekueva, D. A.; Yakimenko, S. P.

    2015-12-01

    An experimental technique for searching for the 2 K capture in 124Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 107 relative to that at the Earth's surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of 124Xe with respect to the 2 K capture is set at the level of 2.5 × 1021 years.

  5. Determination of the influence of asymmetry of the electric field distribution in gaseous proportional counters on their signal amplitude

    International Nuclear Information System (INIS)

    Jagusztyn, W.

    1976-01-01

    A method is described of establishing the influence of the asymmetry of the electric field distribution in gaseous proportional counters on the amplitude of their voltage signal. A numerical evaluation of this effect demands performing calculations of the electric field in the vicinity of the anode. Using the described method of numerical solution of the Laplace equation in polar coordinates with logarythmically scaled radial dimension, it is possible to achieve the required accuracy. In the calculations of differences in amplitudes of voltage signals, for chosen trajektories of electrons liberated in the process of primary ionization, changes in the gaseous amplification factors and drift velocities of positive ions are taken into account. Experimental results prove the validity of presented theory. The results obtained are accurate enough to be applied to the design of proportional counters of non-cylindrical geometries. (author)

  6. The role of different linear and non-linear channels of relaxation in scintillator non-proportionality

    Energy Technology Data Exchange (ETDEWEB)

    Bizarri, G.; Moses, W.W. [Lawrence Berkeley Laboratory, Berkeley, CA 94720-8119 (United States); Singh, J. [Faculty of EHS, B-41, Charles Darwin University, Darwin NT 0909 (Australia); Vasil' ev, A.N., E-mail: anvasiliev@rambler.r [Institute of Nuclear Physics, Moscow State University, Moscow 119991 (Russian Federation); Williams, R.T. [Department of Physics, Wake Forest University, Winston-Salem, NC 27109 (United States)

    2009-12-15

    The non-proportional dependence of a scintillator's light yield on primary particle energy is believed to be influenced crucially by the interplay of non-linear kinetic terms in the radiative and non-radiative decay of excitations versus locally deposited excitation density. A calculation of energy deposition, -dE/dx, along the electron track for NaI is presented for an energy range from several electron-volt to 1 MeV. Such results can be used to specify an initial excitation distribution, if diffusion is neglected. An exactly solvable two-channel (exciton and hole(electron)) model containing 1st and 2nd order kinetic terms is constructed and used to illustrate important features seen in non-proportional light-yield curves, including a dependence on pulse shaping (detection gate width).

  7. The role of different linear and non-linear channels of relaxation in scintillator non-proportionality

    International Nuclear Information System (INIS)

    Bizarri, G.; Moses, W.W.; Singh, J.; Vasil'ev, A.N.; Williams, R.T.

    2009-01-01

    The non-proportional dependence of a scintillator's light yield on primary particle energy is believed to be influenced crucially by the interplay of non-linear kinetic terms in the radiative and non-radiative decay of excitations versus locally deposited excitation density. A calculation of energy deposition, -dE/dx, along the electron track for NaI is presented for an energy range from several electron-volt to 1 MeV. Such results can be used to specify an initial excitation distribution, if diffusion is neglected. An exactly solvable two-channel (exciton and hole(electron)) model containing 1st and 2nd order kinetic terms is constructed and used to illustrate important features seen in non-proportional light-yield curves, including a dependence on pulse shaping (detection gate width).

  8. Determining the level of gross alpha and beta radioactivity of water from Marilao river using liquid scintillation counter

    International Nuclear Information System (INIS)

    Cruz, J.; Magtaka, J.; Balisi, R.; Castaneda, Soledad; De Vero, J.

    2009-01-01

    This study aims to determine the level of gross alpha- and beta- radioactivity present in the Marilao River. Liquid Scintillation Counter was used to detect samples radioactivity. Water samples were taken along the different spots of Marilao River. The results showed that the radioactivity are below the Philippine National Standard for Drinking Water (PNSDW) which is 0.1 Bq/L for gross alpha activity and 1.0 Bq/L for gross beta activity set by the Dept. of Health. Hence water samples from Marilao River, is safe in terms of the level of radioactivity levels.(author)

  9. Tests of the new STIC scintillator ring prototype, the photomultipliers and optic fibers cables of the 40 deg C counters

    International Nuclear Information System (INIS)

    Silva, Tatiana da

    1997-01-01

    This paper reports the tests performed on the semicircular prototype of the new scintillator ring with readings obtained by WLS optic fibers. The prototype intends to verify the light collecting and investigate a method for fiber gluing in a circular surface, without the appearing of air bubbles which may restrain the light transmission. Also the optic fiber cables and the photomultipliers used in the 40 deg C counters have been tested in order to verify the electromagnetic energy which may leak from failures in the barrel, aiming the hermeticity enhancement, and also the existence of any damaged cable

  10. Measurement of the time resolution of small SiPM-based scintillation counters

    Science.gov (United States)

    Kravchenko, E. A.; Porosev, V. V.; Savinov, G. A.

    2017-12-01

    In this research, we evaluated the timing resolution of SiPM-based scintillation detector on a 1-GeV electron beam "extracted" from VEPP-4M. We tested small scintillation crystals of pure CsI, YAP, LYSO, and LFS-3 with HAMAMATSU S10362-33-025C and S13360-3050CS. The CsI scintillator together with HAMAMATSU S13360-3050CS demonstrated the best results. Nevertheless, the achieved time resolution of ~80 ps (RMS) relates mainly to the photodetector itself. It makes the silicon photomultiplier an attractive candidate to replace other devices in applications where sub-nanosecond accuracy is required.

  11. Multi-level modelling of the response of the ultraminiature proportional counter: gas gain phenomena and pulse height spectra

    International Nuclear Information System (INIS)

    Olko, P.; Moutarde, C.; Segur, P.

    1995-01-01

    The ultraminiature proportional counters, UMC, unique radiation detectors for monitoring high intensity therapy fields, designed by Kliauga and operated at Columbia University (USA), have yielded a number of pulse height distributions for photons, neutrons and ions at simulated diameters of 5-50 nm. Monte Carlo calculations of the gas gain in such a counter questioned the possibility of achieving proportionally at such low simulated diameters. The response of the UMC has now been modelled taking into account both fluctuations of energy deposited in the counter volume and its calculated gas gain. Energy deposition was calculated using the MOCA-14, MOCA-8 and TRION codes, whereby distributions of ionisations d(j) after irradiations with 137 Cs, 15 MeV neutrons and 7 MeV.amu -1 deuterons were obtained. Monte Carlo calculations of electron avalanches in UMC show that the size of the single-electron avalanche P(n) reaching the anode depends strongly on the location of the primary ionisation within the counter volume. Distributions of the size of electron avalanches for higher numbers of primary ionisations, P *j (n), were obtained by successive convolutions of P(n). Finally, the counter response was obtained by weighting P *j (n) over d(j) distributions. On comparing the measured and calculated spectra it was concluded that the previously proposed single-electron peak calibration method might not be valid for the UMC due to the excessive width and overlap of electron avalanche distributions. Better agreement between the measured and calculated spectra is found if broader electron avalanche distributions than those used in the present calculations, are assumed. (author)

  12. Time-of-flight resolution of scintillating counters with Burle 85001 microchannel plate photomultipliers in comparison with Hamamatsu R2083

    Energy Technology Data Exchange (ETDEWEB)

    Baturin, V. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Burkert, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Kim, W. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of)]. E-mail: wooyoung@jlab.org; Majewsky, S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Park, K. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Popov, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Smith, E.S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Son, D. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Stepanyan, S.S. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Zorn, C. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States)

    2006-06-15

    Improvements in the time resolution of the CEBAF Large Acceptance Spectrometer (CLAS) below {approx}50ps will be required for experiments using the planned upgraded accelerator facility at Jefferson Lab. The improved time resolution will allow particle identification using time-of-flight techniques to be used effectively up to the proposed operating energy of 12GeV. The challenge of achieving this time resolution over a relatively large area is compounded because the photomultipliers (PM) in the CLAS 'time-zero' scintillating counters must operate in very high magnetic fields. Therefore, we have studied the resolution of 'time-zero' prototypes with microchannel plate PMs 85001-501 from Burle. For reference and comparison, measurements were also made using the standard PMs R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters (Bicron BC-408, 2x3x50cm{sup 3}) with PMs at the ends, yields {sigma}{sub R2083}=59.1+/-0.7ps. The location method of particles from a radiative source with known coordinates has been used to compare timing resolutions of R2083 and 85001-501. This method yields {sigma}{sub R2083}=59.5+/-0.7ps and it also provides an estimate of the number of primary photoelectrons. For the microchannel plate PM from Burle the method yields {sigma}{sub 85001}=130+/-4ps due to lower number of primary photoelectrons.

  13. The Energy Variation of the Sensitivity of a Polyethylene Moderated BF{sub 3} Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Fraeki, R; Leimdoerfer, M; Malmskog, S

    1962-11-15

    The variation with neutron energy of the sensitivity of a polyethylene moderated boron counter has been investigated experimentally at 2.3 MeV, 550 keV, 210 keV, 110 keV, 340 eV and 5 eV, and theoretically by the multigroup diffusion method in the same range. Different moderator thicknesses up to 10 cm were considered Results show good agreement between experimental and theoretical sensitivities for the keV and MeV energies, while a discrepancy of the order of a factor 2 at the most is obtained in the eV region.

  14. Numerical modeling of working of a multicellular proportional counter aimed to individual dosimetry of neutrons

    International Nuclear Information System (INIS)

    Bordy, J.M.; Barthe, J.; Boutruche, B.

    1993-01-01

    The use of a personal dosimeter imposes severe constraints, particularly for tension of polarization and tolerable dimensions. That why a numerical modeling of this detector working is an appreciable help for conception. It allows to determine quickly the influence of modification of different parameters (nature and pressure of gas, dimension of electrodes, dimension of channels, tension of polarization,...) without having to make new prototypes. The aim of this report is to give some numerical results got with a multicellular counter with a cylindrical geometry. 6 figs

  15. PEP quark search proportional chambers

    Energy Technology Data Exchange (ETDEWEB)

    Parker, S I; Harris, F; Karliner, I; Yount, D [Hawaii Univ., Honolulu (USA); Ely, R; Hamilton, R; Pun, T [California Univ., Berkeley (USA). Lawrence Berkeley Lab.; Guryn, W; Miller, D; Fries, R [Northwestern Univ., Evanston, IL (USA)

    1981-04-01

    Proportional chambers are used in the PEP Free Quark Search to identify and remove possible background sources such as particles traversing the edges of counters, to permit geometric corrections to the dE/dx and TOF information from the scintillator and Cerenkov counters, and to look for possible high cross section quarks. The present beam pipe has a thickness of 0.007 interaction lengths (lambdasub(i)) and is followed in both arms each with 45/sup 0/ <= theta <= 135/sup 0/, ..delta..phi=90/sup 0/ by 5 proportional chambers, each 0.0008 lambdasub(i) thick with 32 channels of pulse height readout, and by 3 thin scintillator planes, each 0.003 lambdasub(i) thick. Following this thin front end, each arm of the detector has 8 layers of scintillator (one with scintillating light pipes) interspersed with 4 proportional chambers and a layer of lucite Cerenkov counters. Both the calculated ion statistics and measurements using He-CH/sub 4/ gas in a test chamber indicate that the chamber efficiencies should be >98% for q=1/3. The Landau spread measured in the test was equal to that observed for normal q=1 traversals. One scintillator plane and thin chamber in each arm will have an extra set of ADC's with a wide gate bracketing the normal one so timing errors and tails of earlier pulses should not produce fake quarks.

  16. Application of the pulse-rise-time discriminator for background noise decreasing in proportional x-ray counters

    International Nuclear Information System (INIS)

    Goganov, D.A.; Guslina, A.G.; Korolev, V.F.; Lozinskij, B.S.; Sklyankin, V.A.

    1977-01-01

    The intrinsic background of commercial rising edge discriminator - based proportional counters has been measured. The block-diagram of the experimental apparatus comprises the detector to be tested, a charge-sensitive amplifier with an amplitude analyzer, a rising edge discriminator (RED) and a scaling device. The rising edges have been analyzed in the range between 0.2 to 0.7 of the pulse amplitude. The RED threshold has been preset to cut off all the edges longer than those of 55 Fe (to register 87% of the 55 Fe quanta). It has been found that by limiting the amplitude discriminator window to +-20% and using a RED the background of commercial counters can be reduced by about an order

  17. Discriminator setting and cocktail preparation for analysis of alpha and beta emitters in aqueous solution using liquid scintillation counter

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Zaharudin Ahmad

    2011-01-01

    Liquid scintillation counting (LSC) is not only being used to measure pure beta emitters, but it can be used to measure both alpha and beta emitters simultaneously. Measurement of alpha and beta emitters in aqueous solution is done using a single sample. For the sample preparation, colorless detergent or emulsifier was used to incorporate the water into an organic based scintillator to produce a clear homogeneous solution, since this is the best form to give the highest count rate and detection efficiency. The instrument also need some attention, where after calibration, the LSC was set for the discriminator level which is suitable for measurement of both alpha and beta radiations. In this study, the focus is on the development of the best scintillation cocktail and establishes the best discriminator setting. From this study the best proportion of scintillation cocktail is 2:4:4 for water, toluene, and Triton-N101 (emulsifier) respectively and the best discriminator setting for alpha and beta counting are 120. (author)

  18. Light Distribution in the E3 and E4 Scintillation Counters of the ATLAS Tile Calorimeter

    CERN Document Server

    Hsu, Catherine

    2013-01-01

    The Tile Calorimeter (TileCal) of the ATLAS experiment is an important component of the ATLAS calorimetry because they play a crucial role in the search for new particles. The E3 and E4 are crack scintillators of TileCal that extend into the gap region between the EM barrel and EM endcaps. They thus sample the energy of the EM showers produced by particles interacting with the dead material in the EM calorimeters and with the inner detector cables. This project focuses on the study of the light collection uniformity in the E3 and E4 scintillating tiles using low energy electrons as the ionising particles. It is important to have uniform light response in the tiles because it would ensure a good energy resolution for the dead region. However, many factors affect the uniform light collection within the scintillating tiles.

  19. Long life boron-lined proportional counters fitted to the start-up range of the nuclear reactors

    International Nuclear Information System (INIS)

    Dauphin, G.; Duchene, J.

    1983-03-01

    CEA has been engaged in a research and development program in technical cooperation with RTC, to improve the life time of the boron lined proportional counters used for PWR's start up. The present report is a synthesis of these works. The processes by which the discrimination curves show a shift in count rate versus the neutron fluences are described and, the possible ways to get improved performances and the tests performed on the different prototypes are presented. Analysis of the results is given [fr

  20. A model for the operation of helium-filled proportional counter at low temperatures near 4.2 K

    International Nuclear Information System (INIS)

    Masaoka, Sei; Katano, Rintaro; Kishimoto, Shunji; Isozumi, Yasuhito

    2000-01-01

    In order to understand the operation of helium-filled proportional counter (HFPC) from the standpoint of fundamental atomic and molecular processes, we have surveyed previous works on collision processes in discharged helium gas. By analyzing gas gain curve, after-pulses and discharge current experimentally observed at 4.2 K, the electron avalanche and the secondary electron emission from cathode have been related to the collision processes in helium. A simplified model for the HFPC operation at low temperatures near 4.2 K has been constructed with the related processes

  1. Errors in estimating neutron quality factor using lineal energy distributions measured in tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Borak, T.B.; Stinchcomb, T.G.

    1982-01-01

    Neutron dose equivalent is obtained from quality factors which are defined in terms of LET. It is possible to estimate the dose averaged quality factor, antiQ, directly from distributions in lineal energy, y, that are measured in tissue-equivalent proportional counters. This eliminates a mathematical transformation of the absorbed dose from D(y) to D(L). We evaluate the inherent error in computing Q from D(y) rather than D(L) for neutron spectra below 4 MeV. The effects of neutron energy and simulated tissue diameters within a gas cavity are examined in detail. (author)

  2. A technique for searching for the 2K capture in {sup 124}Xe with a copper proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation); Panasenko, S. I.; Ratkevich, S. S. [Karazin Kharkiv National University (Ukraine); Tekueva, D. A., E-mail: t.jami.a@mail.ru; Yakimenko, S. P. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation)

    2015-12-15

    An experimental technique for searching for the 2K capture in {sup 124}Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 10{sup 7} relative to that at the Earth’s surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of {sup 124}Xe with respect to the 2K capture is set at the level of 2.5 × 10{sup 21} years.

  3. Gas-multiplication factor of a proportional counter operated at low temperature described with the Diethorn, Rose-Korff and townsend expressions

    Energy Technology Data Exchange (ETDEWEB)

    Fukumura, Kazuko; Nakanishi, Akio; Kobayashi, Takayuki [Shiga Univ. of Medical Science, Otsu (Japan)

    1996-07-01

    In the present work, the gas-multiplication factor is expressed with the Rose-Korff and Townsend methods as well as with the Diethorn method. A proportional counter with helium or neon works only at low temperature. This is discussed in terms of the number of electrons emitted when an ion is neutralized at the cathode of the counter. (J.P.N.)

  4. Method and apparstus for determining random coincidence count rate in a scintillation counter utilizing the coincidence technique

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A method and apparatus for the reliable determination of a random coincidence count attributable to chance coincidences of single-photon events which are each detected in only a single detector of a scintillation counter utilizing two detectors in a coincidence counting technique are described. A firstdelay device is employed to delay output pulses from one detector, and then the delayed signal is compared with the undelayed signal from the other detector in a coincidence circuit, to obtain an approximate random coincidence count. The output of the coincidence circuit is applied to an anti-coincidence circuit, where it is corrected by elimination of pulses coincident with, and attributable to, conventionally detected real coincidences, and by elimination of pulses coincident with, and attributable to, real coincidences that have been delayed by a second delay device having the same time parameter as the first. 8 claims

  5. Construction and calibration of a simple scintillation counter for monitoring radioactive gases in ducts

    International Nuclear Information System (INIS)

    Johnston, M.S.

    1984-07-01

    A report is given of the practical construction, laboratory calibration and simple-in-situ calibration check of scintillation detectors used for monitoring radioactive inert gases in gaseous effluents. The βγ-ray and γ-ray detectors are identical except for an absorber which is placed over the window of the γ-ray detector after calibration. The construction and calibration of both detectors is therefore identical. (author)

  6. 90Sr- 90Y and 89Sr beta radioactivity measurement in milk samples using a proportional counter

    International Nuclear Information System (INIS)

    Mananes, A.; Perez Santos, C.; Martinez Churiaque, F.

    1987-01-01

    A thin window glas flow proportional counter is used to measure the 90 Sr- 90 Y and 89 Sr beta radioactivity in milk samples. A chemical procedure is used to separate strontium-yttrium from the other radionuclides present in milk. A calculation of the total efficiency of the system is performed which includes an empirical estimation of the backscattering factor. The calibration of the whole process allows the determination of the 90 Sr activity within 10% relative error in spite of uncertainties in the recovery yields of strontium and yttrium. No 89 Sr activity has been detected, and the mean value obtained for the 90 Sr activity in nine milk samples of Cantabria is 0.115 Bq/1 with a minimum detectable activity of 0.0105 Bq. (author) 18 refs

  7. Detection of pulsed fast neutrons by a proportional counter boron-convered and enveloped in paraffin moderators

    International Nuclear Information System (INIS)

    Goncalez, O.L.; Yanagihara, L.S.; Veissid, V.L.C.P.; Herdade, S.B.

    1983-01-01

    The response to pulsed fast neutrons by a parafin moderated boron-lined proportional counter is investigated theoretically and experimentally. The neutrons pulses are generated by 60 MeV electrons from a linear accelerator. The calculation of the counting loss based on the detector dead time and on the exponential decresse of the thermal neutron population in the moderator is presented in detail. An analytical relation between the true counting rate and the reduced one, indicated by the detector, is found. In this formula three parameters appear: the decay constant of the thermal neutron population, the detector dead time and the pulse frequency of the neutron source. The decay constant is calculated by diffusion theory. The experimental results for six values of moderator thickness (between 2.5 to 12.5 cm) agree with our theoretical calculation within 20 per cent. (Author) [pt

  8. Calibration of the Large Area X-Ray Proportional Counter (LAXPC) Instrument on board AstroSat

    Energy Technology Data Exchange (ETDEWEB)

    Antia, H. M.; Yadav, J. S.; Chauhan, Jai Verdhan; Chitnis, Varsha; Dedhia, Dhiraj; Shah, Parag; Gujar, V. M.; Katoch, Tilak; Kurhade, V. N.; Madhwani, Pankaj; Manojkumar, T. K.; Nikam, V. A.; Pandya, A. S.; Parmar, J. V.; Pawar, D. M. [Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400005 (India); Agrawal, P. C. [UM-DAE Centre of Excellence for Basic Sciences, University of Mumbai, Kalina, Mumbai 400098 (India); Manchanda, R. K. [University of Mumbai, Kalina, Mumbai 400098 (India); Paul, Biswajit [Department of Astronomy and Astrophysics, Raman Research Institute, Bengaluru 560080 (India); Pahari, Mayukh; Misra, Ranjeev [Inter-University Centre for Astronomy and Astrophysics, Pune 411007 (India); and others

    2017-07-01

    We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on board AstroSat . The LAXPC instrument has three nominally identical detectors to achieve a large collecting area. These detectors are independent of each other, and in the event analysis mode they record the arrival time and energy of each photon that is detected. The detectors have a time resolution of 10 μ s and a dead-time of about 42 μ s. This makes LAXPC ideal for timing studies. The energy resolution and peak channel-to-energy mapping were obtained from calibration on the ground using radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab after launch. At around 20 keV the energy resolution of the detectors is 10%–15%, while the combined effective area of the three detectors is about 6000 cm{sup 2}.

  9. Development of a scintillator detector set with counter and data acquisition for flow measurements

    CERN Document Server

    Costa, F E D

    2002-01-01

    A portable counter with data acquisition system for flow measurements was developed, using the pulse velocity technique. This consists in determining the tracer transit time mixed homogeneously to the liquid or gas pipelines. The counter comprises: (a) two CsI(Tl) crystals solid state detectors, associated with Si PIN photodiodes, with compatible sensitivity to the injected radiotracers activities; (b) amplification units; (c) analogue-to-digital interface, which processes and displays the detectors counting separately and in real time, but in a same temporal axis, via a computer screen and (d) 30-m coaxial cables for signals transmission from each detector to the processing unit. Experiments were carried out for the detector and associated electronic characterizations. The equipment showed to be suitable for flow measurements in an industrial plant, in the real situation.

  10. The liquid scintillation counter of the NAVF-It-district Central Norway

    International Nuclear Information System (INIS)

    Traetteberg, J.

    1979-01-01

    NAVF have placed an automatic liquid sciuntillation counter at the disposal of Prof. K. Eik-Nes of the Institute of Biophysics at Trondheim Univ.,Norges Tekniske Hoegskole. The instrument is an uncooled Searle Isocap 300, and is mainly used in biochemical research with radioactive tracers. The apparatus and its operation in 1978 are briefly described. Experience has shown that the instrument is very reliable. (JIW)

  11. New procedure for the determination of radium in water by extraction of radon and application of integral counting with a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Horiuchi, K [Tokyo Metropolitan Univ. (Japan). Faculty of Science; Murakami, Y [Kitasato Univ. (Japan). School of Hygienic Sciences

    1981-05-01

    A new Ra determination method is devised, storing the sample in a glass bottle with a Teflon stopper in an upside-down position, extracting Rn with liquid scintillator solution and combining integral counting with a liquid scintillation counter. This method realizes a high sensitivity of 5 x 10/sup -13/ Ci Ra, eliminates the tedious procedure of transferring Rn through the vacuum system to the detector and makes possible repeated determinations of Ra on the same sample without any further chemical treatment except extraction.

  12. Development of high performance and very low radioactivity scintillation counters for the SuperNEMO calorimeter

    International Nuclear Information System (INIS)

    Chauveau, E.

    2010-11-01

    SuperNEMO is a next generation double beta decay experiment which will extend the successful 'tracko-calo' technique employed in NEMO 3. The main characteristic of this type of detector is to identify not only double beta decays, but also to measure its own background components. The project aims to reach a sensitivity up to 10 26 years on the half-life of 82 Se. One of the main challenge of the Research and Development is to achieve an unprecedented energy resolution for the electron calorimeter, better than 8 % FWHM at 1 MeV. This thesis contributes to improve scintillators and photomultipliers performances and reduce their radioactivity, including in particular the development of a new photomultiplier in collaboration with Photonis. (author)

  13. Tritium Activity Measurement of Water Samples Using Liquid Scintillation Counter and Electrolytical Enrichment

    International Nuclear Information System (INIS)

    Baresic, J.; Krajcar Bronic, I.; Horvatincic, N.; Obelic, B.; Sironic, A.; Kozar-Logar J.

    2011-01-01

    Tritium (3H) activity of natural waters (precipitation, groundwater, surface waters) has recently become too low to be directly measured by low-level liquid scintillation (LSC) techniques. It is therefore necessary to perform electrolytical enrichment of tritium in such waters prior to LSC measurements. Electrolytical enrichment procedure has been implemented at the Rudjer Boskovic Institute (RBI) Tritium Laboratory in 2008, and since then 19 electrolyses have been completed. The mean enrichment factor E (a ratio between the final and initial 3H activities) after stabilisation of the system is E R BI = 22.5 @ 0.5, and the mean enrichment parameter (which describes the process of water mass reduction during electrolysis) is P R BI 0.949 @ 0.003. These values are comparable with those obtained at the Jo@ef Stefan Institute (JSI) Laboratory for liquid scintillation counting, at the electrolysis equipment of the same producer (AGH University of Science and Technology, Krakow, Poland) after 66 electrolyses carried out under identical conditions since 2007: E J SI = 18.9 @ 1.5, and P J SI = 0.896 @ 0.021. Both RBI and JSI laboratories have Ultra-low-level LSC Quantulus 1220 (Wallac, PerkinElmer) for measurement of 3H activity. A set of water samples having 3H activities in the range from 0 TU (''dead-water'' samples) to 18 000 TU (1 TU 0.118 Bq/L) were measured at both laboratories. Samples having 3H activity <200 TU were electrolytically enriched, while the others were measured directly in LSC. A very good agreement was obtained (correlation coefficient 0.991). Both laboratories participated in the IAEA TRIC2008 international intercomparison exercise. The analyses of reported 3H activity results in terms of z and u parameters showed that all results in both laboratories were acceptable. (author)

  14. Measurement of environmental radiation using medical scintillation detector in well counter system

    Energy Technology Data Exchange (ETDEWEB)

    Lyu, Kwang Yeul; Park, Yeon Joon; Kim, Min Jeong; Ham, Eun Hye; Yoon, Ji Yeol; Kim, Hyun in; Min, Jung Hwan; Park, Hoon Hee [Dept. of Radiological Technology, Shingu College, Sungnam (Korea, Republic of)

    2015-12-15

    After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with ‘Captus-3000 thyroid uptake measurement systems’ in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system’s sensitivity. Then we compared the results of each material’s cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like ‘High purity germanium radiation detector’. Moreover, We didn’t have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material’s spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material’s cpm with BKG, we’ve compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A

  15. Measurement of environmental radiation using medical scintillation detector in well counter system

    International Nuclear Information System (INIS)

    Lyu, Kwang Yeul; Park, Yeon Joon; Kim, Min Jeong; Ham, Eun Hye; Yoon, Ji Yeol; Kim, Hyun in; Min, Jung Hwan; Park, Hoon Hee

    2015-01-01

    After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with ‘Captus-3000 thyroid uptake measurement systems’ in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system’s sensitivity. Then we compared the results of each material’s cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like ‘High purity germanium radiation detector’. Moreover, We didn’t have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material’s spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material’s cpm with BKG, we’ve compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A

  16. Realisation and qualification of a tissue equivalent proportional counter with a multi-cellular geometry for the individual neutron dosimetry

    International Nuclear Information System (INIS)

    Hoflack, Ch.

    1999-01-01

    The present day dosimetry means for radiations with a strong ionization density cannot fulfill the future radioprotection regulations which will require an individual dosimetry with active dosemeters. The aim of this work is the study and development of an individual dosemeter based on a tissue equivalent proportional counter and with a multi-cellular geometry allowing to reach a sensibility equivalent to environmental dosemeters. A pressure regulation bench has been added to the detector in order to reduce the degassing of the detector parts and to reach a sufficient service life for the implementation of the characterization tests. The hole counter system has been adopted for the first prototypes in order to reduce the sensibility of the wires multiplication system with respect to mechanical vibrations. Tests performed with an internal alpha source have shown that a better electrical efficiency can be reached when more severe mechanical limits are adopted during the construction. The dose equivalent response of the prototype for mono-energy neutrons of 144 keV to 2.5 MeV is analyzed experimentally and by simulation. During experiments with normal incidence neutrons, the prototype fulfills the requirements of the CEI N O 1323 standard for energies comprised between 400 keV and 2.5 MeV, while the simulation indicates a satisfactory response up to 200 keV. A preliminary study of the behaviour of the detector with respect to the neutrons incidence indicates that the multi-cellular geometry is efficient for large angles (the sensibility of the prototype is increased by a factor 3). Finally, simulation studies have to be made to optimize the electrical operation and the geometry of the next prototype. (J.S.)

  17. GUIDE 7. A general program for evaluating the properties of scintillation and Cerenkov counter optical systems

    International Nuclear Information System (INIS)

    Massam, T.

    1976-01-01

    GUIDE 7 is a design tool for optical systems which are constructed predominantly from reflecting surfaces. A wide range of surface forms and qualities may be chosen and there is provision for the user to extend the range of applicability of the program. Available facilities include estimation of light collection efficiencies, simulation of the space-time intensity distributions of photons arriving at a detector, optimization of the parameters of focusing systems. The report gives a complete description of the program, including user-defined routines. A large-area time-of-flight counter and ray-tracing for a parabolic mirror are treated as examples, detailing the input data and showing the corresponding output. The derivation of the vector algorithms used in the program is also included. (Auth.)

  18. Well scintillation counter with automatic sample changing and data processing: an inexpensive instrument incorporating consumer products

    International Nuclear Information System (INIS)

    Dudley, R.A.; Figdor, H.C.; Keroe, E.A.; Morris, A.C. Jr.; Mutz, O.J.

    1977-01-01

    An automatic well scintillation-counting system suitable for in vitro assays with 125 I has been designed with the express purpose of allowing effective operation and maintenance in laboratories in developing countries. The system incorporates comparatively simple components, notably two consumer products: A Kodak Carousel slide projector as sample changer and a Hewlett-Packard HP-97 programmable printing calculator as system controller and data processor. The instrument can accomodate 80 counting vials of demensions 12 mm diameter x 75 mm, or 40 vials of 16 mm diameter x 100 mm. The calculator provides on-line control and data reduction with the mediation of an interface somewhat resembling that required between a scaler and a printer. Its program capacity is adequate for fairly complicated on-line operations, including, interpolation from a standard curve in logit-log space, calculation of error in hormone concentration, and termination of counting when the counting error is rediced to a prescribed fraction of the composite of other random assay errors (as stored in the calculator's memory). This system is inexpensive, robust, and capable of being operated manually if automatic accessories fail. It could be improved in several ways, particularly by providing for operation from batteries and, no doubt in the immediate future, substitution of the next generation of cheaper and more powerful calculators. The instrument may be cost-effective in any small to medium-sized laboratory. (orig.) [de

  19. Measurement and analysis of neutron flux distribution of STACY heterogeneous core by position sensitive proportional counter. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Murazaki, Minoru; Uno, Yuichi; Miyoshi, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    We have measured neutron flux distribution around the core tank of STACY heterogeneous core by position sensitive proportional counter (PSPC) to develop the method to measure reactivity for subcritical systems. The neutron flux distribution data in the position accuracy of {+-}13 mm have been obtained in the range of uranium concentration of 50g/L to 210g/L both in critical and in subcritical state. The prompt neutron decay constant, {alpha}, was evaluated from the measurement data of pulsed neutron source experiments. We also calculated distribution of neutron flux and {sup 3}He reaction rates at the location of PSPC by using continuous energy Monte Carlo code MCNP. The measurement data was compared with the calculation results. As results of comparison, calculated values agreed generally with measurement data of PSPC with Cd cover in the region above half of solution height, but the difference between calculated value and measurement data was large in the region below half of solution height. On the other hand, calculated value agreed well with measurement data of PSPC without Cd cover. (author)

  20. Measurement and analysis of neutron flux distribution of STACY heterogeneous core by position sensitive proportional counter. Contract research

    CERN Document Server

    Murazaki, M; Uno, Y

    2003-01-01

    We have measured neutron flux distribution around the core tank of STACY heterogeneous core by position sensitive proportional counter (PSPC) to develop the method to measure reactivity for subcritical systems. The neutron flux distribution data in the position accuracy of +-13 mm have been obtained in the range of uranium concentration of 50g/L to 210g/L both in critical and in subcritical state. The prompt neutron decay constant, alpha, was evaluated from the measurement data of pulsed neutron source experiments. We also calculated distribution of neutron flux and sup 3 He reaction rates at the location of PSPC by using continuous energy Monte Carlo code MCNP. The measurement data was compared with the calculation results. As results of comparison, calculated values agreed generally with measurement data of PSPC with Cd cover in the region above half of solution height, but the difference between calculated value and measurement data was large in the region below half of solution height. On the other hand, ...

  1. Calculations of the response functions of Bonner spheres with a spherical 3He proportional counter using a realistic detector model

    International Nuclear Information System (INIS)

    Wiegel, B.; Alevra, A.V.; Siebert, B.R.L.

    1994-11-01

    A realistic geometry model of a Bonner sphere system with a spherical 3 He-filled proportional counter and 12 polyethylene moderating spheres with diameters ranging from 7,62 cm (3'') to 45,72 cm (18'') is introduced. The MCNP Monte Carlo computer code is used to calculate the responses of this Bonner sphere system to monoenergetic neutrons in the energy range between 1 meV to 20 MeV. The relative uncertainties of the responses due to the Monte Carlo calculations are less than 1% for spheres up to 30,48 cm (12'') in diameter and less than 2% for the 15'' and 18'' spheres. Resonances in the carbon cross section are seen as significant structures in the response functions. Additional calculations were made to study the influence of the 3 He number density and the polyethylene mass density on the response as well as the angular dependence of the Bonner sphere system. The calculated responses can be adjusted to a large set of calibration measurements with only a single fit factor common to all sphere diameters and energies. (orig.) [de

  2. Construction of a self-supporting tissue-equivalent dividing wall and operational characteristics of a coaxial double-cylindrical tissue-equivalent proportional counter

    International Nuclear Information System (INIS)

    Saion, E.B.; Watt, D.E.

    1994-01-01

    An additional feature incorporated in a coaxial double-cylindrical tissue-equivalent proportional counter, is the presence of a common tissue-equivalent dividing wall between the inner and outer counters of thickness equivalent to the corresponding maximum range of protons at the energy of interest. By appropriate use of an anti-coincidence arrangement with the outer counter, the inner counter could be used to discriminate microdosimetric spectra of neutrons at the desired low energy range from those of the faster neutrons. The construction of an A-150 self-supporting tissue-equivalent dividing wall and an anti-coincidence unit are described. Some operational characteristic tests have been performed to determine the operation of the new microdosimeter. (author)

  3. Nuclear accident dosimetry: the calibration of Geiger-Mueller and 2π proportional counters for sulphur and gold

    International Nuclear Information System (INIS)

    Delafield, H.J.; Reading, A.H.

    1981-10-01

    A reference, 2π precision counter was set up at Harwell and absolutely calibrated for the measurement of sulphur discs ( 32 P) and gold foils ( 198 Au) used in the UK personnel criticality dosimeter. Sample sulphur discs and gold foils were irradiated in the GLEEP reactor at Harwell, counted in the 2π counter, and their activities absolutely assayed by the National Physical Laboratory. The 2π counter was then used to intercalibrate the GM counters used routinely for the assessment of the criticality dosimeter. The mean measured efficiencies of the GM counters were found to be for 32 P in sulphur discs within +- 4%, and for gold ( 198 Au) within +- 6% of the values given by previous calibrations. (author)

  4. An investigation of the effect of some gaseous admixtures on the ionization currents in the air in the discharge chambers of the proportional counter type

    International Nuclear Information System (INIS)

    Berdowska, E.; Zastawny, A.

    1981-01-01

    Voltage-current characteristics of the ionization discharge in chambers of the proportional counter filled with air with admixtures of CO, CO 2 , CH 4 and H 2 O have been investigated. It was found that in the transition region between dependent and self-maintained discharge the characteristics change sufficiently for detection of the presence of those admixtures in the air. (author)

  5. Qualitative and quantative analysis of some physical processes encountered in measurements of low level radon activity by means of proportional counter

    International Nuclear Information System (INIS)

    Bluszcz, A.; Moscicki, W.

    1980-01-01

    Physical model for absorption of radon and its decay products on the electrodes of the proportional counter filled with Rn-CO 2 mixture is presented. The results of calculations based on developed model are compared with observed changes of counting rate of radon and its decay products. (author)

  6. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  7. Comparison of the quantulus 1220 and 300SL liquid scintillation counters for the analysis of {sup 222}Rn in groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Jung, Yoon Hee; Lee, Wanno; Choi, Guen Sik; Chung, Kun Ho; Kang, Mun Ja [Environmental Radioactivity Assessment Team, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting {sup 222}Rn in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect {sup 222}Rn in groundwater. The Quantulus 1220 and 300SL were used to detect the presence of {sup 222}Rn. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a {sup 222}Rn calibration source prepared with a {sup 226}Ra source. The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was 0.08 Bq·L{sup -,} while that of the 300SL was 0.20 Bq·L{sup -1}. The analytical results regarding {sup 222}Rn in groundwater were less than 10% different between these LSCs. The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting {sup 222}Rn in groundwater. Both LSCs can be applied to determine the levels of {sup 222}Rn in groundwater under the management of the Ministry of Environment.

  8. The design and performance of a large-volume spherical CsI(Tl) scintillation counter for gamma-ray spectroscopy

    CERN Document Server

    Meng, L J; Chirkin, V M; Potapov, V N; Ivanov, O P; Ignatov, S M

    2002-01-01

    This paper presents details of the design and performance of a prototype large-volume scintillation detector used for gamma-ray spectroscopy. In this detector, a spherical CsI(Tl) scintillation crystal having a diameter of 5.7 cm was polished and packed in dry MgO powder. The scintillation light from the crystal was viewed using a single 1x1 cm sup 2 silicon PIN diode. A low-noise preamplifier was also integrated within the detector housing. The measured noise level was equivalent to approx 800 electrons (FWHM). Such a configuration provided a very good light collection efficiency, which resulted in an average of 20 electrons being generated per keV of energy deposited in the crystal. One of the key features of the detector design is that it minimises spatial variations in the light collection efficiency throughout the detector. Compared with a standard 3 in. NaI scintillation counter, this feature leads to a much-improved energy resolution, particularly for photon energies above 1 MeV. The results presented ...

  9. First results of a simultaneous measurement of tritium and 14C in an ultra-low-background proportional counter for environmental sources of methane

    Energy Technology Data Exchange (ETDEWEB)

    Mace, Emily K.; Aalseth, Craig E.; Day, Anthony R.; Hoppe, Eric W.; Keillor, Martin E.; Moran, James J.; Panisko, Mark E.; Seifert, Allen; Tatishvili, Gocha; Williams, Richard M.

    2016-02-01

    Abstract Simultaneous measurement of tritium and 14C would provide an added tool for tracing organic compounds through environmental systems and is possible via beta energy spectroscopy of sample-derived methane in internal-source gas proportional counters. Since the mid-1960’s atmospheric tritium and 14C have fallen dramatically as the isotopic injections from above-ground nuclear testing have been diluted into the ocean and biosphere. In this work, the feasibility of simultaneous tritium and 14C measurements via proportional counters is revisited in light of significant changes in both the atmospheric and biosphere isotopics and the development of new ultra-low-background gas proportional counting capabilities for small samples (roughly 50 cc methane). A Geant4 Monte Carlo model of a Pacific Northwest National Laboratory (PNNL) proportional counter response to tritium and 14C is used to analyze small samples of two different methane sources to illustrate the range of applicability of contemporary simultaneous measurements and their limitations. Because the two methane sources examined were not sample size limited, we could compare the small-sample measurements performed at PNNL with analysis of larger samples performed at a commercial laboratory. The dual-isotope simultaneous measurement is well matched for methane samples that are atmospheric or have an elevated source of tritium (i.e. landfill gas). For samples with low/modern tritium isotopics (rainwater), commercial separation and counting is a better fit.

  10. Study of colour quenching effects in the calibration of liquid scintillation counters: the case of sup 2 sup 1 sup 0 Pb

    CERN Document Server

    Villa, M; Manjon, G

    2003-01-01

    In this work a rigorous method for the calibration of a liquid scintillation counter for sup 2 sup 1 sup 0 Pb activity determination is proposed. The variation of the PSA threshold level for alpha/beta discrimination with the colour quenching is analysed for different beta energies. Also the changes in some parameters of the detector response, as the muon-peak, the channel ratio and the centroid of the spectrum, due to colour quenching are studied. The relationship between such parameters and the counting efficiency is described in such a way that the effects of colour in the efficiency are established. sup 9 sup 9 Tc is proposed as a good standard to calibrate the counter for sup 2 sup 1 sup 0 Pb determination in real samples.

  11. The study of vial and cocktail for tritium radioactivity analysis of rain water by liquid scintillation counter

    International Nuclear Information System (INIS)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Lee, Man Woo; Jeong, Dong Hyeok; Yang, Kwang Mo; Kang, Yeong Rok; Nam, Sang Hee

    2015-01-01

    Even though the current method for tritium (3H) analysis is routine, for the case of the low level of tritium in the environment, special conditions have to be fulfilled in order to obtain accurate and reliable tritium measurements. There are very little comparative data concerning commercial scintillating cocktails. The best cocktails for measuring tritium are those based on benzene derived solvent, and the worse cocktails are those which have complex chemical composition or contain too small concentration of scintillators. The aim of study was to investigate various vials and cocktails by comparison with the combination of few different scintillation cocktails and vials in our routine measurements according to count, efficiency, and the figure of merit (FOM). The comparison of three types of vials with scintillation cocktails for tritium activity analysis of rain water shows that glass vials have higher count rates and HiSafe 3 cocktails have lower FOM

  12. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples

    International Nuclear Information System (INIS)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L.

    2014-10-01

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  13. Search of 2K(2ν) capture in 78 Kr and 124 Xe by means of wall-less proportional counters

    International Nuclear Information System (INIS)

    Volchenko, G.V.; Gavrilyuk, Yu.M.; Kuz'minov, V.V.; Osetrova, N.Ya.; Ratkevich, S.S.

    1998-01-01

    The technique of the experiment on the double two-neutrino K-capture search in isotopes of rare gases 78 Kr and 124 Xe is described. Multiwire wall-less proportional counters of a large volume are used in this experiment. Methods of decreasing the counter background noise in the energy range 10-100 keV are considered. These methods are based on the discrimination of events on the coordinate along the anode filament and the pulse rise time. The sensitivity of the experimental installation is estimated according to the half-life 78 Kr (1.2 x 10 21 years) and 124 Xe (2.6 x 10 20 years) with respect to the 2K(2ν) capture (68% certain level)

  14. A new scintillation counter with very fast resolving time (1961); Nouveau compteur a scintillation a tres faible temps de resolution (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The rare gases used as scintillators are characterized by their short time of luminescence and by the linearity of their response as a function of the total energy imparted to the gas by the incident particle. It is possible with these scintillators, when associated with a fast response photomultiplier, to solve certain problems of nuclear physics demanding a linear detector with a very fast resolving time (a few nanoseconds). Two examples of the construction of this apparatus are described. The results obtained and future possibilities are briefly outlined. (author) [French] Les gaz rares utilises comme scintillateurs sont caracterises par leur faible duree de luminescence et par la linearite de leur reponse en fonction de l'energie totale cedee au gaz par la particule incidente. Ces scintillateurs, associes a un photomultiplicateur a une reponse rapide, permettent de resoudre certains problemes de physique nucleaire dans lesquels un detecteur lineaire a tres faible temps de resolution (quelques nanosecondes) se revele indispensable. Deux exemples de realisation sont decrits. Les resultats obtenus et les possibilites futures sont brievement exposes. (auteur)

  15. From the High Energy Physics Laboratory to the hospital -some experiences of the application of MWPC [multiwire proportional counter] technology to medicine

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1989-01-01

    In this talk I wish to briefly review the experience we have obtained at the Rutherford Appleton Laboratory over the past decade in the adaptation of MWPC (multiwire proportional counter) technology to diagnostic imaging applications in medicine. A cursory glance at the history of science and technology quickly shows the often intimate and mutually beneficial relationship between ''pure'' science (and scientists) and practical applications. The following talk traces some of the principal features of the situation which have been brought to my attention in the course of the last decade. (author)

  16. High efficiency scintillation detectors

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1976-01-01

    A scintillation counter consisting of a scintillation detector, usually a crystal scintillator optically coupled to a photomultiplier tube which converts photons to electrical pulses is described. The photomultiplier pulses are measured to provide information on impinging radiation. In inorganic crystal scintillation detectors to achieve maximum density, optical transparency and uniform activation, it has been necessary heretofore to prepare the scintillator as a single crystal. Crystal pieces fail to give a single composite response. Means are provided herein for obtaining such a response with crystal pieces, such means comprising the combination of crystal pieces and liquid or solid organic scintillator matrices having a cyclic molecular structure favorable to fluorescence. 8 claims, 6 drawing figures

  17. Monte Carlo calculations and experimental results of Bonner spheres systems with a new cylindrical Helium-3 proportional counter

    CERN Document Server

    Müller, H; Bouassoule, T; Fernández, F; Pochat, J L; Tomas, M; Van Ryckeghem, L

    2002-01-01

    The experimental results on neutron energy spectra, integral fluences and equivalent dose measurements performed by means of a Bonner sphere system placed inside the containment building of the Vandellos II Nuclear Power Plant (Tarragona, Spain) are presented. The equivalent dose results obtained with this system are compared to those measured with different neutron area detectors (Berthold, Dineutron, Harwell). A realistic geometry model of the Bonner sphere system with a new cylindrical counter type 'F' (0,5NH1/1KI--Eurisys Mesures) and with a set of eight polyethylene moderating spheres is described in detail. The response function in fluence of this new device, to mono-energetic neutrons from thermal energy to 20 MeV, is calculated by the MCNP-4B code for each moderator sphere. The system has been calibrated at IPSN Cadarache facility for ISO Am-Be calibrated source and thermal neutron field, then the response functions were confirmed by measurements at PTB (Germany) for ISO recommended energies of mono-e...

  18. Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Altun, Zeki; Abdel-Rehim, Mohamed

    2008-01-01

    Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples. In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 μL utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 x 250 μL elution solution and then with 3 x 250 μL washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS

  19. Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Altun, Zeki [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Abdel-Rehim, Mohamed [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Clinical Pharmacology and DMPK, AstraZeneca R and D Soedertaelje, SE-151 85 Soedertaelje (Sweden)], E-mail: Mohamed.Abdel-Rehim@Astrazeneca.com

    2008-12-23

    Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 {mu}L) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples. In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 {mu}L utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 x 250 {mu}L elution solution and then with 3 x 250 {mu}L washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS.

  20. Scintillation Counters for Neutron Scattering Experiments; Compteurs a scintillations pour les experiences de diffusion neutronique; Stsintillyatsionnye schetchiki dlya ehksperimentov s rasseyaniem nejtronov; Contadores de centelleo para experimentos de dispersion neutronica.

    Energy Technology Data Exchange (ETDEWEB)

    Harris, D; Duffil, C [Atomic Energy of Canada Ltd., Chalk River, Ontario (Canada); Wraight, L A [Aere, Harwell, Didcot, Berks (United Kingdom)

    1963-01-15

    Scintillation counters discussed in this paper are of two types : (i) UP or B{sub 2}O{sub 3} fixed with zinc sulphide in varving composition, (ii) Li containing glasses of varying composition. The ideal composition of each rype for neutron scattering experiments and their relative sensitivity tae neutrons and {gamma}-rays are considered. The ZnS type can be used with a {gamma}-ray pulse shape discriminator and practical experience of its use in a multi-counter time-of-flight experiment is described. The Li glass has higher {gamma}-background but also higher neutron efficiency. Performance figures of a scintillator containing 25% by wt. Li{sub 2}O and 1 mm thick will be given. (author) [French] Les compteurs a scintillations etudies sont de deux types : i) LiF ou B{sub 2}O{sub 3} fixe par du sulfure de zinc en composition variable, ii) verres contenant du lithium en composition variable. Les auteurs examinent la composition ideale de chaque type de compteur pour les experiences de diffusion de neutrons, ainsi que leur sinsibilite rrelative aux neutrons et aux rayons gamma. On peut utiliser le compteur a ZnS avec un discriminates de forme pour rayons gamma; les auteurs decrivent l'experience qu'ils ont de son emploi dans une experience de temps de vol a plusieurs compteurs. Le compteur verre-Li a un mouvement propre plus eleve pour les rayons gamma mais une meilleure efficacite vis-a-vis des neutrons. Les auteurs donnent quelques chiffres concernant le fonctionnement d'un scintillateur contenant 25% en poids de Li{sub 2}O et ayant une epaisseur de un millimetre. (author) [Spanish] Los contadores de centelleo examinados en esta memoria son de dos tipos : a) de LiF o B{sub 2}O{sub 3} mezclado con sulfuro de cinc en proporciones variables; b) de vidrios litiados de diversas composiciones. Los autores estudian la composicion ideal de cada tipo para experimentos de dispersion neutronica, asi como su sensibilidad relativa a los neutrones y a los rayos gamma. El tio de Zn

  1. Test beam results using scintillating fibers read out by a multianode phototube and visible light photon counters

    International Nuclear Information System (INIS)

    Abbott, B.; Davies, R.; Koltick, D.; McIlwain, R.; Schmitz, C.J.; Shibata, E.I.; Atac, M.; Baumbaugh, B.; Jaques, J.; Kehoe, R.; Marchant, J.; Ruchti, R.; Warchol, J.; Wayne, M.; Binkley, M.; Elias, J.; Goldberg, H.; Margulies, S.; Solomon, J.; Armstrong, T.; Lewis, R.; Smith, G.

    1993-01-01

    The results from a test beam experiment at Fermilab using 830 μm scintillating fibers, a version of a solid state photomultiplier, the VLPC, and a 256 channel multianode phototube are reported. Muon tracks were observed in a combined tracking system read out by VLPCs and the multianode phototube. A tracking algorithm was developed to unfold the complex cross talk pattern observed in the multianode phototube. A spatial resolution of ∝130 μm was obtained. (orig.)

  2. Quality assurance regime for the fabrication and calibration of ambient dose rate measuring instruments with proportional counters

    International Nuclear Information System (INIS)

    Schloesser, H.

    1997-01-01

    The proportional detectors FHZ 600A and FHZ 601A serve as examples to illustrate the quality assurance regime applied in fabrication and operation of the detector. Calibration is done by a licensed establishment connected to the standard 137 Cs calibration source at PTB. In addition to the basic calibration, the intrinsic selfdosing effect of the device and its response to cosmic radiation are known and can be taken into account in interpretations of measured results. The individual calibration of the intelligent probes of type FHZ 601A achieves a yet better measuring accuracy at higher dose rates, as compared to the basic calibration and performance of the FHZ 600A probes, as was shown by a type approval test. The paper also shows that control measurements and ''intelligent'' measuring systems with integrated checking routines improve the measuring reliability. (orig./CB) [de

  3. Design and performance of a one square meter proportional counter system for hard X-ray astronomy

    International Nuclear Information System (INIS)

    Bazzano, A.; Boccaccini, L.; La Padula, C.D.; Mastropietro, M.; Patriarca, R.; Polcaro, F.; Ubertini, P.

    1983-01-01

    A versatile balloon borne hard X-ray experiment with a very large area (approx.= 1.1 m 2 ) and high spectral resolution has been developed for the study of the hard X-ray sources in the energy range 20-180 keV. The telescope consists of four multiwire proportional chambers (MWPC) that have a geometrical sensitive area of 2700 cm 2 each. The detector system has a sensitivity of approx.= 10 -5 photons cm -2 s -1 keV -1 during a typical balloon observation. A background rate of approx.= 3 x 10 -4 counts cm -2 s -1 keV -1 was observed in the operative energy range at 2.4 gm/cm 2 ceiling altitude and geographic latitude of 38 0 N. The design details, fabrication and flight performance of the instrument are briefly discussed with reference to the effectiveness of background reduction and other test parameters. (orig.)

  4. Design and performance of a one square meter proportional counter system for hard X-ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Bazzano, A.; Boccaccini, L.; La Padula, C.D.; Mastropietro, M.; Patriarca, R.; Polcaro, F.; Ubertini, P. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale); Manchanda, R.K. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale; Tata Inst. of Fundamental Research, Bombay (India))

    1983-09-01

    A versatile balloon borne hard X-ray experiment with a very large area (approx.= 1.1 m/sup 2/) and high spectral resolution has been developed for the study of the hard X-ray sources in the energy range 20-180 keV. The telescope consists of four multiwire proportional chambers (MWPC) that have a geometrical sensitive area of 2700 cm/sup 2/ each. The detector system has a sensitivity of approx.= 10/sup -5/ photons cm/sup -2/ s/sup -1/ keV/sup -1/ during a typical balloon observation. A background rate of approx.= 3 x 10/sup -4/ counts cm/sup -2/ s/sup -1/ keV/sup -1/ was observed in the operative energy range at 2.4 gm/cm/sup 2/ ceiling altitude and geographic latitude of 38/sup 0/N. The design details, fabrication and flight performance of the instrument are briefly discussed with reference to the effectiveness of background reduction and other test parameters.

  5. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter); Determinacao de atividades alfa e beta total em agua para consumo humano por LSC (Contador de Cintilacao Liquida))

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  6. Calibration of a low background gas-flow proportional counter to estimate "2"3"4Th activity in coastal waters

    International Nuclear Information System (INIS)

    Cuesta, E.; Lozano, R.L.; Miguel, E.G. San; Casas-Ruiz, M.; Bolívar, J.P.

    2016-01-01

    This paper relates the calibration of a low background gas-flow proportional counter. This calibration has been used to determine low activity of "2"3"4Th in coastal water samples. Two methods were used to prepare calibration samples: Evaporation and Electrodeposition. First method was rejected due to the lack of reproducibility because the different geometry adopted by the drops of tracer once dried on the disk. On the contrary, through the second method, similar efficiencies were obtained in all detectors with an average of 0.401±0.004. In this paper, the whole procedure to obtain "2"3"4Th activity in dissolution as well as in particulate matter has been detailed, and all the algorithms needed to calculate activities and efficiencies are shown. Finally, two experiments have been designed in order to validate the calibration of the beta counter and the method to determine "2"3"4Th in coastal waters with high concentration of particulate matter. - Highlights: • This paper shows a Home-made calibration using two methods to prepare calibration samples. • The algorithms needed to obtain Th-234 activity concentrations are described in full detail. • This is the first time Th-234 has been determined in water samples from Huelva Estuary.

  7. Einstein Observatory SSS and MPC observations of the complex X-ray spectra of Seyfert galaxies. [Solid State Spectrometer and Monitor Proportional Counter

    Science.gov (United States)

    Turner, T. J.; Weaver, K. A.; Mushotzky, R. F.; Holt, S. S.; Madejski, G. M.

    1991-01-01

    The X-ray spectra of 25 Seyfert galaxies measured with the Solid State Spectrometer on the Einstein Observatory have been investigated. This new investigation utilizes simultaneous data from the Monitor Proportional Counter, and automatic correction for systematic effects in the Solid State Spectrometer which were previously handled subjectively. It is found that the best-fit single-power-law indices generally agree with those previously reported, but that soft excesses of some form are inferred for about 48 percent of the sources. One possible explanation of the soft excess emission is a blend of soft X-ray lines, centered around 0.8 keV. The implications of these results for accretion disk models are discussed.

  8. Development of portable Liquid Scintillation counters for on-site primary measurement of radionuclides using the Triple-to-Double Coincidence Ratio method

    International Nuclear Information System (INIS)

    Cassette, P.; Capogni, M.; De Felice, P.; Johansson, L.; Sephton, J.; Kossert, K.; Naehle, O.

    2013-06-01

    The Triple-to-Double Coincidence Ratio (TDCR) method in Liquid Scintillation counting (LSC) is a primary radionuclide standardization method widely used in National Metrology laboratories and was primarily developed for the activity measurement of beta emitters. It is based on liquid scintillation: the light is detected by three photomultipliers (PM) and the detection efficiency is evaluated by using a model which uses the ratio of triple-to-double coincidences between the PM tubes. Up to now, most of current TDCR systems were locally-made metrology instruments neither aimed at nor suitable for in-situ measurements. In the framework of the European Metrofission project, a work package was dedicated to the realisation of miniature self-calibrated primary TDCR systems, which are state-of-the-art, for use on-site. The challenge was to develop a versatile portable, table-top designed instrument, from this metrology device. This implied improvements for the miniaturisation of the detection chamber, for the miniaturisation of electronic modules by exploring the possibilities of digital treatment, and for the validation of models and extension of them to nuclides with special beta spectrum shapes, to nuclides with complex decay schemes including many gamma-rays and to nuclides with higher atomic number decaying by electron capture. Four prototypes of counters were built by the Metrofission partners ENEA (Italy), LNHB (France), NPL (UK) and PTB (Germany) using various technical approaches. The paper describes these prototypes and provides some details on the choice of the technical options concerning the design of the optical chamber, of the photodetectors and of the acquisition system. (authors)

  9. Set of counts by scintillations for atmospheric samplings; Ensemble de comptages par scintillations pour prelevements atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Appriou, D.; Doury, A.

    1962-07-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies.

  10. Temperature behaviour of photo-emissive films. The case of photo-multipliers used in scintillation counters

    International Nuclear Information System (INIS)

    Ardalan, A.H.

    1966-01-01

    This work concerns the changes in the spectral sensitivity of 3 types of normal photo-cathodes (Cs 3 Sb, tri-alkali and bi-alkali without cesium) as a function of temperature. The photo-cathodes of cathodes of commercial photomultipliers (DARIO, E.M.I., R.C.A., A.S.C.O.F.) were used for these tests. The temperature range studied was -25 C to +55 C (except for the bi-alkali photo-cathodes which were tested up to +150 C) and the wave-length range was 3250 to 7000 angstrom. After a brief review of photo-electric effect theories, the experimental device is described and the measurement results presented. Finally, an interpretation of these results is proposed. For the normal range of scintillator emission, i.e. between 3000 and 5000 angstroms (Na I (Tl), plastics, anthracene) the temperature coefficient is always negative: -0.15 % C for Cs 3 Sb and up to -0.5 % C for the most temperature-sensitive photo-cathode. Above 5000 angstrom, the temperature coefficient of Cs 3 Sb films becomes positive: +0.5 % C on the overage. The accuracy of the spectral sensitivity measurements is ±4 % in absolute value and ±1 % in relative value. (author) [fr

  11. A measurement of the efficiency for the detection of neutrons in the momentum range 200 to 3200 MeV/c, in large volume liquid scintillation counters

    International Nuclear Information System (INIS)

    Brown, R.M.; Clark, A.G.; Duke, P.J.

    1976-04-01

    A description is given of a system of 194 large volume liquid scintillation counters designed to detect neutrons in an experiment on the reaction π - p → π 0 n in the resonance region. The detection efficiency of the system has been determined, as a function of neutron momentum, in three separate measurements, covering the range 200 to 3200 MeV/c. Below 400 MeV/c the efficiency shows the expected momentum dependence near threshold, rising to a maximum of 50% near 300 MeV/c and then falling to 43% near 400 MeV/c. In the region 400 to 700 MeV/c the efficiency rises to 47% near 600 MeV/c and falls again to 43%, an effect not seen before; the efficiency was expected to be almost momentum independent in this region. Above the threshold for inelastic processes in nucleon-nucleon collision (approximately 800 MeV/c) the efficiency rises significantly reaching a maximum value of 65% above 1700 MeV/c. (author)

  12. Relation between the measured results of radon concentration in ground water by liquid scintillation counter and the geology in Aichi Prefecture

    International Nuclear Information System (INIS)

    Shimizu, Michihiko; Onuma, Akiko; Chaya, Kunio; Hamamura, Norikatsu

    1982-01-01

    The radon ( 222 Rn) concentrations in ground water were measured by the liquid scintillation counter (LSC) method at 47 points in Aichi Prefecture. Then, the relation between the distribution of measured radon concentrations and the geology in the prefecture was examined. The areas with high radon concentration are located in the granite zones of the pre-Cenozoic era (the Mikawa mountainous region) and the average concentration was 35.5 +- 43.3 ( x 10 - 10 Ci Rn/l) (n = 22). The areas with low concentration are located in the sedimentary formation zones (the Nobi plain, Chita Peninsula), and the average concentration was 3.5 +- 3.0 ( x 10 - 10 Ci Rn/l) (n = 20). The secular changes in radon concentration in ultra deep ground waters of 1,000 m or more were investigated at eith points in the Nobi plain for seven years from 1975 to 1981. The coefficients of variation at Sobue and Dai-Nagoya hot springs were stable 4.7% and 6.8%, respectively, showing no secular changes. (J.P.N.)

  13. Relation between the measured results of radon concentration in ground water by liquid scintillation counter and the geology in Aichi Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, M.; Onuma, A.; Chaya, K.; Hamamura, N. (Aichi Prefectural Inst. of Public Health, Nagoya (Japan))

    1982-01-01

    The radon (/sup 222/Rn) concentrations in ground water were measured by the liquid scintillation counter (LSC) method at 47 points in Aichi Prefecture. Then, the relation between the distribution of measured radon concentrations and the geology in the prefecture was examined. The areas with high radon concentration are located in the granite zones of the pre-Cenozoic era (the Mikawa mountainous region) and the average concentration was 35.5 +- 43.3 ( x 10/sup -10/ Ci Rn/l) (n = 22). The areas with low concentration are located in the sedimentary formation zones (the Nobi plain, Chita Peninsula), and the average concentration was 3.5 +- 3.0 ( x 10/sup -10/ Ci Rn/l) (n = 20). The secular changes in radon concentration in ultra deep ground waters of 1,000 m or more were investigated at eight points in the Nobi plain for seven years from 1975 to 1981. The coefficients of variation at Sobue and Dai-Nagoya hot springs were stable 4.7% and 6.8%, respectively, showing no secular changes.

  14. Optimization of Counting Times, Figure of Merit and Mass Thickness for Low-background Alpha/beta Proportional Counter in Sea Water

    International Nuclear Information System (INIS)

    Pakkong, Pannee; Wongsanit, Sarinya; Tumnoi, Yutthana; Udomsomporn, Suchin

    2011-06-01

    Full text: The determination of gross alpha and beta activity in environmental aqueous samples can be done by using a low-background alpha/beta proportional counter with multiple detector type (Bert hold LB770). The co precipitate sea water samples were considered for optimal regime of counting time, the minimum detectable activity (MDA), mass thickness of samples (mg/cm-2) and figure of merit (FOM). The result showed that the MDA of the measurements were estimated to be 0.07 Bq/l for gross alpha and 0.05 Bq/l for gross beta at counting time of 100 and 200 minute, respectively. The thickness of samples prepared by coprecipitation technique indicated more parochial range when compared to evaporation to dryness method. In addition, the samples were in the suitable range that can be corrected by the previous self-absorption correction factor (F a ) as 0.0003w 2 -0.0414 w+1.692; where F a is the self-absorption correction factor and w is the weight of the final precipitate in milligrams

  15. Study and full simulation of ten different gases on sealed Multi-Wire Proportional Counter (MWPC) by using Garfield and Maxwell codes

    International Nuclear Information System (INIS)

    Shohani, M. Ebrahimi; Golgoun, S.M.; Aminipour, M.; Shabani, A.; Mazoochi, A.R.; Akbari, R. Maghsoudi; Mohammadzadeh, M.; Davarpanah, M.R.; Sardari, D.; Sadeghi, M.; Mofrad, F. Babapour; Jafari, A.

    2016-01-01

    In this research gas sealed Multi-Wire Proportional Counter (MWPC) including blades between anode wires and beta particles of "9"0Sr with 196 keV mean energy were considered. Ten different gases such as Noble gases mixtures with methane and several other pure gases were studied. In this type of detector, by using Garfield and Maxwell codes and for each of the gases, variation of different parameters such as first Townsend, electron attachment coefficients with variable electric field and their effects on pulse height or collected charge and in turn on Signal to Noise Ratio (SNR) were studied. Also the effect of anode voltage and its diameter and the pressure of gas on the pulse height were studied. Results show that Garfield and Maxwell codes can be used to study and improve the design of other gaseous detectors. - Highlights: • Simulation of different gases that is applicable for various gas detectors. • Two simulation codes were used and analyzed their results for beta particle. • Different detector parameters were studied (SNR, first Townsend, electron attachment coefficients, anode voltage and etc.). • The effect of blade in the detector were assessed. • The codes are useful for design and improvement of detector.

  16. The response of a spherical tissue-equivalent proportional counter to 56-Fe particles from 200-1000 MeV/nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Gersey, Bradford B.; Borak, Thomas B.; Guetersloh, Stephen B.; Zeitlin, Cary J.; Miller, J.; Heilbronn, L.; Murakami, T.; Iwata, Y.

    2001-09-04

    The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1 micron diameter sphere of tissue was exposed as part of a particle spectrometer to iron-56 at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of frequency-averaged lineal energy, dose-averaged lineal energy, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of iron-56 in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model and the results compared to experimental data.

  17. Use of the helium-3 proportional counter for neutron spectrometry; Utilisation du compteur proportionnel a helium 3 pour la spectrometrie des neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Vialettes, H; Le Thanh, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Up to now, two methods have been mainly used for neutron spectrometry near nuclear installations: - photographic emulsion spectrometry - the so-called, 'multisphere' technique spectrometry. The first method, which is fairly difficult to apply, has a threshold energy of about 500 keV; this is a big disadvantage for an apparatus which has to be used for spectrometry around nuclear installations where the neutron radiation is very much degraded energetically. The second method does not suffer from this disadvantage but the results which it yields are only approximate. In order to extend the energy range of the neutron spectra studied with sufficient accuracy the use of a helium-3 proportional counter has been considered. This report presents the principles of operation of the helium-3 spectrometer, and the calculation methods which make it possible to take into account the two main effects tending to deform the spectra obtained: - energy absorption by the walls of the counter, - energy loss of the incident neutrons due to elastic collisions with helium-3 nuclei. As an example of the application, the shape of the neutron spectrum emitted by a polonium-lithium source is given; the results obtained are in excellent agreement with theoretical predictions. (authors) [French] Jusqu'ici deux methodes ont ete utilisees principalement pour la spectrometrie des neutrons autour des installations nucleaires: - la spectrometrie par emulsions photographiques - la spectrometrie par la technique dite des multispheres. La premiere methode, d'un emploi assez delicat presente un seuil en energie d'environ 500 keV qui est un obstacle serieux a la spectrometrie autour des installations nucleaires ou le rayonnement neutronique est tres degrade en energie. La deuxieme methode ne presente pas cet inconvenient mais les resultats qu'elle permet d'obtenir ne sont qu'approches. Pour etendre la gamme d'energie des spectres de neutrons etudies avec une precision suffisante, l'utilisation du

  18. Systematic studies of small scintillators for new sampling calorimeter

    International Nuclear Information System (INIS)

    Jacosalem, E.P.; Sanchez, A.L.C.; Bacala, A.M.; Iba, S.; Nakajima, N.; Ono, H.; Miyata, H.

    2007-01-01

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R and D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are systematically studied. The scintillation light due to beta rays from a collimated 90 Sr source are collected from the scintillator by wavelength-shifting (WLS) fiber and converted into electrical signals at the PMT. The wrapped scintillator that gives the best light yield is determined by comparing the measured pulse height of each 10 x 40 x 2 mm strip scintillator covered with 3M reflective mirror film, teflon, white paint, black tape, gold, aluminum and white paint+teflon. The pulse height dependence on position, length and thickness of the 3M reflective mirror film and teflon wrapped scintillators are measured. Results show that the 3M radiant mirror film-wrapped scintillator has the greatest light yield with an average of 9.2 photoelectrons. It is observed that light yield slightly increases with scintillator length, but increases to about 100% when WLS fiber diameter is increased from 1.0 mm to 1.6 mm. The position dependence measurement along the strip scintillator showed the uniformity of light transmission from the sensor to the PMT. A dip across the strip is observed which is 40% of the maximum pulse height. The block type scintillator pulse height, on the other hand, is found to be almost proportional to scintillator thickness. (author)

  19. Rapid actinide analysis method coupling liquid chromatography/ICP-MS and "9"0Sr gas proportional counter in post-accidental situation environmental samples

    International Nuclear Information System (INIS)

    Habibi, Azza

    2015-01-01

    The present study follows the Fukushima power plant accident and aimed to develop an analytical method to achieve, during an emergency situation, a rapid identification and quantification of alpha and beta emitters in environmental samples. The first step of this study allowed us to list the alpha and beta emitters which can be released in the environment in case of a nuclear accident. The second step aimed towards the development of a rapid analysis method to quantify 17 radionuclides of U, Th, Pu, Am, Np and Sr. The main objective was the automation of the radiochemical separation step and its coupling for the measurement. The separation is performed using columns containing extraction resins, namely TEVA, TRU and Sr. The measurement is performed using an ICP-MS (inductively coupled plasma mass spectrometry) and in some cases a gas proportional counter to quantify radiostrontium ("8"9Sr and "9"0Sr). Excellent figures of merit were obtained, off line, with water (tap, river and sea water) and solid matrices (soil and aerosol filters), after a micro-wave digestion or an alkaline fusion dissolution followed by a Ca_3(PO_4)_2 coprecipitation. The proposed analytical strategy showed yields between 70 % and 100 % and standard deviations between 5 % and 10 %. The newly developed separation method was then automated and coupled on-line to ICP-MS. The operating parameters were optimized using a design of experiments and the results were processed with Minitab. The optimized automated separation coupled on-line to the ICP-MS allows the rapid quantification, in 1.5 h per sample, of U, Th, Pu, Am, Np and Sr with detection limits gain as high as 20 times for artificial radionuclide. (author)

  20. Study and construction of a new type of gaseous scintillator

    International Nuclear Information System (INIS)

    Khoury, H.J.

    1978-01-01

    The characteristics and constructional details of a new type of gas scintillation counter is presented. It is shown that using an electric field in a cylindrical geometry and operating the counter in a proportional region, the number of photons due to the excitation of rare gas (argon) during the passage of an ionising primary particle, is considerably increased. The effect of the intensity of applied eletric field is discussed and it is shown that the use of suitable electric field improves the resolution of scintillation counter. The use of several Waveshifters for shifting the ultraviolet component of photon spectrum into the sensitive region of the photomultiplier tube is discussed and the experimental results are presented. A source of Am 241 was used to verify the influence of electric field on alpha spectra. (Author) [pt

  1. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  2. New proportional counter for in vivo detection of traces of plutonium in the lungs; Nouveau compteur proportionnel destine a la detection in vivo de traces de plutonium dans les poumons

    Energy Technology Data Exchange (ETDEWEB)

    Morucci, J [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    Development of a multi-wire proportional counter having a uniform response over 250 cm{sup 2} thanks to corrections made for boundary effects, and having a low background per sq. cm. due to the use of two identical counters set in anti-coincidence in the same enclosure is described. (author) [French] Etude et mise au point d'un compteur proportionnel multifils de reponse utile homogene sur une surface de 250 cm{sup 2} grace a la correction des effets de bords et de faible mouvement propre par cm{sup 2} grace a deux compteurs identiques montes en anticoincidence dans la meme enceinte. (auteur)

  3. Application of a proportional counter to some particular cases of {alpha} measurements; Applications d'un compteur proportionnel a quelques cas particuliers de mesures {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Ferret, J; Gasc, M T; Le Du, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    I - A measurement method based on {alpha} {gamma} coincidences is used for activity measurements on {sup 241}Am in the presence of a strong {alpha} activity due to Pu. The sensitivity of the apparatus makes it possible to detect: less than 10{sup -7} {mu}C {sup 241}Am in the presence of a Pu activities several hundred times greater. II - The same equipment has been used for {alpha} measurements on {alpha}-emitting sources in the presence of very strong {beta} and {gamma} activities. In particular results are given for {alpha}-activity measurements on powder samples. It is even possible in these conditions, to detect or measure {sup 241}Am. III - The equipment makes possible also: - the absolute calibration of a pure {sup 241}Am source - {sup 237}Np measurements - simultaneous measurements of {alpha}, {beta} and {gamma} activities in solid samples in various forms. IV - The assembly includes a small-size proportional counter operating in conjunction with a {gamma} probe, together with auxiliary electronic equipment (stabilized high voltages, amplifiers, a coincidence unit, a sealer). (authors) [French] I - Une methode de mesures par coincidences {alpha} {gamma} est utilisee pour des mesures d'activite de {sup 241}Am en presence d'activite {alpha} (due au Pu) importante. -La sensibilite de l'appareillage permet de deceler: moins de 10{sup -7} {mu}C {sup 241}Am dans les activites {alpha} Pu plusieurs centaines de fois plus importantes. II - Le meme appareillage a ete utilise pour des mesures {alpha} sur des sources emettrices {alpha} en presence d'activites {beta} et {gamma} tres importantes. En particulier des mesures d'activite {alpha} sur des echantillons de poudre sont exposees. Il est meme possible, dans ces conditions, de deceler ou mesurer {sup 241}Am. III - L'ensemble permet egalement: - l'etalonnage absolu d'une source de {sup 241}Am pur - des mesures de {sup 237}Np - des mesures simultanees d'activites {alpha}, {beta} et {gamma} dans des echantillons solides

  4. A new type of a gas scintillating chamber

    International Nuclear Information System (INIS)

    Khoury, H.J.

    1981-01-01

    In a previous paper (H.J. Khoury - thesis - 1978) the author has described a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. New experiments are described which contribute to a deeper understanding of the phenomena involved in the scintillating chamber due to the nature of the gas, the electric field and spatial distribution, etc.. The behaviour of the gas scintillation counter is studied both in the proportional region and in the region of limited proportionality. It is shown that by the use of a suitable gas mixture and applied electric field, the resolution of an alpha particle spectrum is considerably increased and values up to 0,9% can be attained. (Author) [pt

  5. Development of NRESP98 Monte Carlo codes for the calculation of neutron response functions of neutron detectors. Calculation of the response function of spherical BF{sub 3} proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, M.; Saito, K.; Ando, H. [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-05-01

    The method to calculate the response function of spherical BF{sub 3} proportional counter, which is commonly used as neutron dose rate meter and neutron spectrometer with multi moderator system, is developed. As the calculation code for evaluating the response function, the existing code series NRESP, the Monte Carlo code for the calculation of response function of neutron detectors, is selected. However, the application scope of the existing NRESP is restricted, the NRESP98 is tuned as generally applicable code, with expansion of the geometrical condition, the applicable element, etc. The NRESP98 is tested with the response function of the spherical BF{sub 3} proportional counter. Including the effect of the distribution of amplification factor, the detailed evaluation of the charged particle transportation and the effect of the statistical distribution, the result of NRESP98 calculation fit the experience within {+-}10%. (author)

  6. Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    CERN Document Server

    Akindinov, A.; Grigoriev, E.; Grishuk, Yu.; Kuleshov, S.; Mal'kevich, D.; Martemiyanov, A.; Nedosekin, A.; Ryabinin, M.; Voloshin, K.

    2009-01-01

    A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (MRS APD). START delivers 100% efficiency of cosmic muon detection, while its intrinsic noise level is less than 10^{-2} Hz. CRTF, consisting of 160 START channels, has been continuously operated by the ALICE TOF collaboration for more than 25 000 hours, and has demonstrated a high level of stability. Fewer than 10% of MRS APDs had to be replaced during this period.

  7. Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and Some Preliminary Results from its performance in the orbit

    OpenAIRE

    Agrawal, P. C.; Yadav, J. S.; Antia, H. M.; Dedhia, Dhiraj; Shah, P.; Chauhan, Jai Verdhan; Manchanda, R. K.; Chitnis, V. R.; Gujar, V. M.; Katoch, Tilak; Kurhade, V. N.; Madhwani, P.; Manojkumar, T. K.; Nikam, V. A.; Pandya, A. S.

    2017-01-01

    Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency g...

  8. 4{pi} proportional counter for absolute measurement of {beta}-emitters; Compteur 4{pi} proportionnel destine a la mesure absolue d'emetteurs {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Perolat, J P; Laine, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The 4{pi} counter is commonly used to measure the activity of {beta} sources, the one we describe does not advance a new conception but the issue of several years of investigations. The apparatus presents good performances about the qualities commonly required in that kind of counter: detection efficiency, plateau and dead time. Moreover technical characteristics give a great flexibility in use, particularly a possibility of adaptation in a {beta},{gamma} coincidence unit. (authors) [French] Le compteur 4{pi} proportionnel est couramment, utilise pour mesurer l'activite de sources {beta}, celui que nous decrivons ne represente pas une conception nouvelle, mais plutot l'aboutissement de plusieurs annees d'etudes. Cette installation presente des performances satisfaisantes en ce qui concerne les qualites habituellement requises dans ce type de compteur: l'efficacite de detection, le palier et le temps mort. En outre, certaines caracteristiques techniques qui lui sont propres lui conferent une grande souplesse d'utilisation, en particulier la possibilite d'adaptation a un ensemble de mesures par coincidences 4{pi} {beta} {gamma}. (auteurs)

  9. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  10. Proportionality lost - proportionality regained?

    DEFF Research Database (Denmark)

    Werlauff, Erik

    2010-01-01

    In recent years, the European Court of Justice (the ECJ) seems to have accepted restrictions on the freedom of establishment and other basic freedoms, despite the fact that a more thorough proportionality test would have revealed that the restriction in question did not pass the 'rule of reason' ...

  11. View of the VO prototype made of two sectors of scintillating counters. WLS fibers embedded within connectors appear in green color. Beams of optical fibers inside black sheath collect and transport the emitted light to photo-multipliers a few meters apart.

    CERN Multimedia

    2004-01-01

    View of the VO prototype made of two sectors of scintillating counters. WLS fibers embedded within connectors appear in green color. Beams of optical fibers inside black sheath collect and transport the emitted light to photo-multipliers a few meters apart.

  12. Cadmium Sulfide Quantum Dot Particles (CdSQD Dispersed in Poly Methyl Methacrylate as an Effective Gamma Counter for the Scintillation Detector

    Directory of Open Access Journals (Sweden)

    Askari Mohammad Bagher

    2017-08-01

    Full Text Available The synthetic material, cadmium sulfide quantum dot particles (CdSQD, using a hydrothermal method was dispersed in poly methyl methacrylate (PMM polymer. In order to study the synthesized quantum dot particles, X-ray diffraction (XRD and Fourier transform infrared spectroscopy (FTIR techniques were applied. Transmission electron microscopy (TEM and scanning electron microscopy (SEM images were also used to study the surface morphology of synthetic quantum dot particles. Energy-dispersive X-ray spectroscopy (EDX test was done for identification of constituent percent of prepared material. Optical properties of CdSQD particles were evaluated by UV-visible and photoluminescence spectroscopy (PL. Finally the capability of CdSQD particles dispersed in poly methyl methacrylate (CdSQD@PMM as a scintillator material was investigated by photomultiplier tube (PMT test. The result of PMT test along with statistical studies showed that the CdSQD@PMM can be applied as a crystalline promising material in the field of inorganic scintillator detectors regarding to the efficiency and economic aspects.

  13. An introduction to automatic radioactive sample counters

    International Nuclear Information System (INIS)

    1980-01-01

    The subject is covered in chapters, entitled; the detection of radiation in sample counters; nucleonic equipment; liquid scintillation counting; basic features of automatic sample counters; statistics of counting; data analysis; purchase, installation, calibration and maintenance of automatic sample counters. (U.K.)

  14. Scintillator structures

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1978-01-01

    Distributed phosphor scintillator structures providing superior optical coupling to photoelectrically responsive devices together with methods for fabricating said scintillator structures are disclosed. In accordance with one embodiment of the invention relating to scintillator structures, the phosphor is distributed in a 'layered' fashion with certain layers being optically transparent so that the visible wavelength output of the scintillator is better directed to detecting devices. In accordance with another embodiment of the invention relating to scintillator structures, the phosphor is distributed throughout a transparent matrix in a continuous fashion whereby emitted light is more readily transmitted to a photodetector. Methods for fabricating said distributed phosphor scintillator structures are also disclosed. (Auth.)

  15. Liquid Scintillation Counting - Packard Triple-Label Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Torretto, P. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-23

    The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

  16. Applications of liquid scintillation tubes

    International Nuclear Information System (INIS)

    Broga, D.W.

    1977-01-01

    A new cocktail containing device for liquid scintillation counting, the scintillation tube, consists of a two-layered plastic bag which is heatsealed after the cocktail and sample have been placed in it. It is then placed in a carrying vial and counted in a conventional liquid scintillation counter. These tubes have proved to be a practical and economical alternative to vials. Some of their advantages are elimination of absorption problems, transparency, lower background and higher counting efficiency, low breakage danger and savings in waste disposal costs. Two applications for which the tubes are particularly suitable are the counting of laboratory swipes and urine analysis. (author)

  17. Efficiency determination of whole-body counters by Monte Carlo method, using a microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computing program using Monte Carlo method for calculate the whole efficiency of distributed radiation counters in human body is developed. A simulater of human proportions was used, of which was filled with a known and uniform solution containing a quantity of radioisopes. The 99m Tc, 131 I and 42 K were used in this experience, and theirs activities compared by a liquid scintillator. (C.G.C.) [pt

  18. Scintillation scanner

    International Nuclear Information System (INIS)

    Mehrbrodt, A.W.; Mog, W.F.; Brunnett, C.J.

    1977-01-01

    A scintillation scanner having a visual image producing means coupled through a lost motion connection to the boom which supports the scintillation detector is described. The lost motion connection is adjustable to compensate for such delays as may occur between sensing and recording scintillations. 13 claims, 5 figures

  19. Status of timing with plastic scintillation detectors

    International Nuclear Information System (INIS)

    Moszynski, M.; Bengtson, B.

    1979-01-01

    Timing properties of scintillators and photomultipliers as well as theoretical and experimental studies of time resolution of scintillation counters are reviewed. Predictions of the theory of the scintillation pulse generation processes are compared with the data on the light pulse shape from small samples, in which the light pulse shape depends only on the composition of the scintillator. For larger samples the influence of the light collection process and the self-absorption process on the light pulse shape are discussed. The data on rise times, fwhm's, decay times and light yield of several commercial scintillators used in timing are collected. The next part of the paper deals with the properties of photomultipliers. The sources of time uncertainties in photomultipliers as a spread of the initial velocity of photoelectrons, emission of photoelectrons under different angles and from different points at the photocathode, the time spread and the gain dispersion introduced by electron photomultiplier are reviewed. The experimental data on the time jitter, single electron response and photoelectron yield of some fast photomultipliers are collected. As the time resolution of the timing systems with scintillation counters depends also on time pick-off units, a short presentation of the timing methods is given. The discussion of timing theories is followed by a review of experimental studies of the time resolution of scintillation counters. The paper is ended by an analysis of prospects on further progress of the subnanosecond timing with scintillation counters. (Auth.)

  20. Evaluation of filters in RSPCS (Reactor Service Pool Cooling System) and HWL (Hot Water Layer) in OPAL research reactor at ANSTO (Australian Nuclear Science and Technology Organization) using Gamma Spectrometry System and Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jim In; Foy, Robin; Jung, Seong Moon; Park, Hyeon Suk; Ye, Sung Joon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Australian Nuclear Science and Technology Organization(ANSTO) has a research reactor, OPAL (Open Pool Australian Lightwater reactor) which is a state-of-art 20 MW reactor for various purposes. In OPAL reactor, there are many kinds of radionuclides produced from various reactions in pool water and those should be identified and quantified for the safe use of OPAL. To do that, it is essential to check the efficiency of filters which are able to remove the radioactive substance from the reactor pool water. There are two main water circuits in OPAL which are RSPCS (Reactor Service Pool Cooling System) and HWL (Hot Water Layer) water circuits. The reactor service pool is connected to the reactor pool via a transfer canal and provides a working area and storage space for the spent and other materials. Also, HWL is the upper part of the reactor pool water and it minimize radiation dose rates at the pool surface. We collected water samples from these circuits and measured the radioactivity by using Gamma Spectrometry System (GSS) and Liquid Scintillation Counter (LSC) to evaluate the filters. We could evaluate the efficiency of filters in RSPCS and HWL in OPAL research reactor. Through the measurements of radioactivity using GSS and LSC, we could conclude that there is likely to be no alpha emitter in water samples, and for beta and gamma activity, there are very big differences between inlet and outlet results, so every filter is working efficiently to remove the radioactive substance.

  1. Optimization of mass of plastic scintillator film for flow-cell based tritium monitoring: a Monte Carlo study

    International Nuclear Information System (INIS)

    Roy, Arup Singha; Palani Selvam, T.; Raman, Anand; Raja, V.; Chaudhury, Probal

    2014-01-01

    Over the years, various types of tritium-in-air monitors have been designed and developed based on different principles. Ionization chamber, proportional counter and scintillation detector systems are few among them. A plastic scintillator based, flow-cell type online tritium-in-air monitoring system was developed for online monitoring of tritium in air. The value of the scintillator mass inside the cell-volume, which maximizes the response of the detector system, should be obtained to get maximum efficiency. The present study is aimed to optimize the amount of mass of the plastic scintillator film for the flow-cell based tritium monitoring instrument so that maximum efficiency is achieved. The Monte Carlo based EGSnrc code system has been used for this purpose

  2. An efficient anticoincidence counter

    CERN Multimedia

    1977-01-01

    This scintillation counter (about 25 cm diameter) was prepared at CERN for an experiment at the Saclay 600 MeV electron linac studying molecular processes originated in liquid hydrogen by muons. The counter is meant to surround the target and detect charged particles emerging from the hydrogen. The experiment was a CERN-Saclay collaboration which used the linac so as to take advantage of the time structure of the electron beam(see CERN Courier Sep 1977 and J. Bardin et al. Phys. Lett. B104 (1981) 320)

  3. Temperature behaviour of photo-emissive films. The case of photo-multipliers used in scintillation counters; Comportement en temperature des couches photoemissives. Cas des photomultiplicateurs utilises dans les compteurs a scintillations

    Energy Technology Data Exchange (ETDEWEB)

    Ardalan, A H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    This work concerns the changes in the spectral sensitivity of 3 types of normal photo-cathodes (Cs{sub 3}Sb, tri-alkali and bi-alkali without cesium) as a function of temperature. The photo-cathodes of cathodes of commercial photomultipliers (DARIO, E.M.I., R.C.A., A.S.C.O.F.) were used for these tests. The temperature range studied was -25 C to +55 C (except for the bi-alkali photo-cathodes which were tested up to +150 C) and the wave-length range was 3250 to 7000 angstrom. After a brief review of photo-electric effect theories, the experimental device is described and the measurement results presented. Finally, an interpretation of these results is proposed. For the normal range of scintillator emission, i.e. between 3000 and 5000 angstroms (Na I (Tl), plastics, anthracene) the temperature coefficient is always negative: -0.15 % C for Cs{sub 3}Sb and up to -0.5 % C for the most temperature-sensitive photo-cathode. Above 5000 angstrom, the temperature coefficient of Cs{sub 3}Sb films becomes positive: +0.5 % C on the overage. The accuracy of the spectral sensitivity measurements is {+-}4 % in absolute value and {+-}1 % in relative value. (author) [French] Cette etude porte sur la variation de la sensibilite spectrale de 3 types de photocathodes usuelles (Cs{sub 3}Sb, trialcalines et bialcalines sans cesium) en fonction de la temperature. Des photocathodes de photomultiplicateurs du commerce (DARIO, E.M.I., R.C.A., A.S.C.O.P.) ont fait l'objet de ces essais. Le domaine examine s'etendait en temperature de -25 C a +55 C (sauf pour les photocathodes bialcalines qui ont ete portees a une temperature de +150 C) et en longueur d'onde de 3250 a 7000 angstrom. Apres un rappel des theories de l'effet photoelectrique, le dispositif experimental est decrit et les resultats des mesures exposes. Enfin, une interpretation de ces resultats est proposee. Dans le domaine de l'emission des scintillateurs usuels, c'est-a-dire entre 3000 et 5000 angstrom (Na I (Tl), plastiques

  4. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a energie egale, plus faibles

  5. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a

  6. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  7. Proportional reasoning

    DEFF Research Database (Denmark)

    Dole, Shelley; Hilton, Annette; Hilton, Geoff

    2015-01-01

    Proportional reasoning is widely acknowledged as a key to success in school mathematics, yet students’ continual difficulties with proportion-related tasks are well documented. This paper draws on a large research study that aimed to support 4th to 9th grade teachers to design and implement tasks...

  8. Scintillation camera

    International Nuclear Information System (INIS)

    Zioni, J.; Klein, Y.; Inbar, D.

    1975-01-01

    The scintillation camera is to make pictures of the density distribution of radiation fields created by the injection or administration radioactive medicaments into the body of the patient. It contains a scintillation crystal, several photomultipliers and computer circuits to obtain an analytical function at the exits of the photomultiplier which is dependent on the position of the scintillations at the time in the crystal. The scintillation crystal is flat and spatially corresponds to the production site of radiation. The photomultipliers form a pattern whose basic form consists of at least three photomultipliers. They are assigned to at least two crossing parallel series groups where a vertical running reference axis in the crystal plane belongs to each series group. The computer circuits are each assigned to a reference axis. Each series of a series group assigned to one of the reference axes in the computer circuit has an adder to produce a scintillation dependent series signal. Furthermore, the projection of the scintillation on this reference axis is calculated. A series signal is used for this which originates from a series chosen from two neighbouring photomultiplier series of this group. The scintillation must have appeared between these chosen series. They are termed as basic series. The photomultiplier can be arranged hexagonally or rectangularly. (GG/LH) [de

  9. Characterisation of a ultra-miniature counter for microdosimetric measurements in a therapeutic 400 MeV/A carbon beam

    International Nuclear Information System (INIS)

    Endo, S.; Takada, M.; Ishikawa, M.; Hoshi, M.; Uehara, S.; Yamaguchi, H.; Kanai, T.; Matsufji, N.; Shizuma, K.; Onizuka, Y.

    2002-01-01

    Single event spectra of a clinical carbon beam have been measured by an ultra-miniature tissue-equivalent proportional counter (UMC). In order to cover the energy range of the Bragg peak, the incident energy of the carbon beam was degraded by aluminium plates. Single event spectra for carbon-events incident to the UMC were analysed and selected at several carbon energies using thin scintillation counters. It was found that the dose weighted lineal energy distributions have a doublet peak structure due to incident carbon beam and fragment contributions. (author)

  10. Crate counter for normal operating loss

    International Nuclear Information System (INIS)

    Harlan, R.A.

    A lithium-loaded zinc sulfide scintillation counter to closely assay plutonium in waste packaged in 1.3 by 1.3 by 2.13m crates was built. In addition to assays for normal operating loss accounting, the counter will allow safeguards verification immediately before shipment of the crates for burial. The counter should detect approximately 10 g of plutonium in 1000 kg of waste

  11. Direct Measurement of Tritium in Biological Materials with the Liquid Scintillation Counter; Determination quantitative directe du tritium dans les substances biologiques, au moyen de compteurs a scintillations a liquides; Neposredstvennoe izmerenie kolichestva tritiya v biologicheskikh materialakh pri pomoshchi zhidkogo stsintillyatsionnogo schetchika; Determinacion cuantitativa directa del tritio en sustancias biologicas mediante contadores de centelleador liquido

    Energy Technology Data Exchange (ETDEWEB)

    Halvorsen, K [Institutt for Atomenergi, Kjeller, Lillestroem (Norway)

    1962-01-15

    Procedures for measurement of tritium in animal tissues and isolated tissue fractions have been reported in the literature. In all the work reported, however, a liquid scintillation coincidence spectrometer has been used for the counting of the samples. In this work a single phototube liquid scintillation counter was used for the measurements. Investigation centred primarily on the direct dissolution of animal tissue in Hyamine 10-X and the suspension counting of lyophilized tissue in scintillating gels. Different tissues, such as liver, intestine, blood and skin, can be dissolved directly in Hyamine and measured with an efficiency of 10-15%. The techniques of quenching correction and certain phosphorescence phenomena as they affect the counting in a single phototube counting system are discussed. The sensitivity of the method, although somewhat less than that of the coincidence-counting arrangement, seems to be sufficient for many applications. The work reported was carried out on tissue samples from mice previously injected with tritium- labelled thymidine. When a dose of approximately 1 {mu}c tritiated thymidine per g of body weight was injected into the mice, the metabolic fate of the thymidine incorporated into deoxyribonucleic acid (DNA) of the various tissues could be followed for a period of one month. (author) [French] Diverses techniques de determination du tritium dans les tissus animaux et fractions isolees de tissus animaux ont deja ete decrites. Mais toutes comportent l'emploi d'un spectrometre de coincidences a scintillations a liquides pour le comptage des echantillons. Pour faire cette determination, l'auteur s'est servi d'un seul phototube-compteur a scintillations a liquides. Il a etudie surtout la dissolution directe de tissu animal dans de l'hyamine 10-X, et le comptage de tissus lyophilises en suspension dans des gels a scintillations. Certains tissus, tels que le foie, l'intestin, le sang et la peau, peuvent Etre dissous directement dans l

  12. 2003: A centennial of spinthariscope and scintillation counting

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Hollander, W. den

    2004-01-01

    In 1903 W. Crookes demonstrated in England his 'spinthariscope' for the visual observation of individual scintillations caused by alpha particles impinging upon a ZnS screen. In contrast to the analogue methods of radiation measurements in that time the spinthariscope was a single-particle counter, being the precursor of scintillation counters since. In the same period F. Giesel, J. Elster and H. Geitel in Germany also found that scintillations from ZnS represent single particle events. This paper summarises the historical events relevant to the advent of scintillation counting

  13. Rapid method for determining Sr-89 and Sr-90 using Cherenkov and proportional counting; Schnellmethode zur Bestimmung von SR-89 und SR-90 durch Cerenkov- und Proportionalzaehlermessungen

    Energy Technology Data Exchange (ETDEWEB)

    Lange, S.; Wende, C.; Schwokowski, R.; Alisch-Mark, M.; Abraham, A.; Heinrich, T. [Staatliche Betriebsgesellschaft fuer Umwelt und Landwirtschaft, Radebeul (Germany)

    2016-07-01

    A rapid method for determining Sr-89 and Sr-90 in water, milk and biological samples has been developed and tested. After sample preparation strontium is separated by extraction chromatography using Sr resin. Eluate is divided and transfered to LSC vial and filter paper by SrCO{sub 3} precipitation. A Hidex 300 SL TDCR liquid scintillation counter and Thermo Fisher low level proportional counter have been used. Chemical yield of Sr-85 tracer is determined by Gamma spectroscopy. Uncertainty budget, decision threshold and detection limit are calculated in accordance with GUM and ISO 11929.

  14. Plastic scintillator

    International Nuclear Information System (INIS)

    Andreeshchev, E.A.; Kilin, S.F.; Kavyrzina, K.A.

    1978-01-01

    A plastic scintillator for ionizing radiation detectors with high time resolution is suggested. To decrease the scintillation pulse width and to maintain a high light yield, the 4 1 , 4 5 -dibromo-2 1 , 2 5 , 5 1 , 5 5 -tetramethyl-n-quinquiphenyl (Br 2 Me 4 Ph) in combination with n-terphenyl (Ph 3 ) or 2, 5-diphenyloxadiazol-1, 3, 4 (PPD) is used as a luminescent addition. Taking into consideration the results of a special study, it is shown, that the following ratio of ingradients is the optimum one: 3-4 mass% Ph 3 or 4-7 mas% PPD + 2-5 mass% Br 2 Me 4 Ph + + polymeric base. The suggested scintillator on the basis of polystyrene has the light yield of 0.23-0.26 arbitrary units and the scintillation pulse duration at half-height is 0.74-0.84 ns

  15. Development of multiwire proportional chambers

    CERN Multimedia

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  16. Applications of low level liquid scintillation counting

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1983-01-01

    Low level liquid scintillation counting is reviewed in terms of its present use and capabilities for measuring low activity samples. New areas of application of the method are discussed with special interest directed to the food industry and environmental monitoring. Advantages offered in the use of a low background liquid scintillation counter for the nuclear power industry and nuclear navy are discussed. Attention is drawn to the need for commercial development of such instrumentation to enable wider use of the method. A user clientele is suggested as is the required technology to create such a counter

  17. Quality control of total alpha and beta activity analysis in water using the Proportional Counter of Gaseous Flux technique; Controle de qualidade das análises de atividades alfa e beta total em água pela técnica do Contador Proporcional de Fluxo Gasoso

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Alberto P.; Bastos, Thiago M.R.; Santos, Thiago O.; Filho, Crescêncio A.S.; França, Elvis J. de, E-mail: albertopereiran@gmail.com, E-mail: thiagomrbastos@gmail.com, E-mail: thiago_cbufpe@yahoo.com.br, E-mail: candrade@cnen.gov.br, E-mail: ejfranca@cnen.gov.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2017-07-01

    The analytical capacity of the CRCN (Centro Regional de Ciências Nucleares do Nordeste) for quantification of total alpha and beta concentrations in water samples using the Proportional Counter of Gaseous Flux is presented. To demonstrate the traceability of the results, the National Intercomparison Program (PNI) samples were used, promoted by the Institute of Radioprotection and Dosimetry (IRD) from which the Regional Nuclear Science Center of the Northeast (CRCN-NE) participates since 2011. The results reported to the PNI demonstrate the analytical capacity of the CRCN to detect the emission of alpha and beta radioactivities in water within the potability standards in analytical detection of quantification in radioactivity by the technique of the Proportional Flow Counter.

  18. The 'miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Bellettini, G.

    2002-01-01

    Muon detection is fundamental to many of the interesting analyses at CDF II. For more efficient muon registration in Run II it was decided to increase geometrical coverage. The so-called 'miniskirt' counters are part of this upgrade. The original design parameters of the 'miniskirt' and mixed 'miniskirt' scintillation counters for the CDF Muon System are presented. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of mixed 'miniskirt' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns

  19. A Neutron Rem Counter

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J

    1964-01-15

    A neutron detector is described which measures the neutron dose rate in rem/h independently of the energy of the neutrons from thermal to 15 MeV. The detector consists of a BF{sub 3} proportional counter surrounded by a shield made of polyethylene and boron plastic that gives the appropriate amount of moderation and absorption to the impinging neutrons to obtain rem response. Two different versions have been developed. One model can utilize standard BF{sub 3} counters and is suitable for use in installed monitors around reactors and accelerators and the other model is specially designed for use in a portable survey instrument. The neutron rem counter for portable instruments has a sensitivity of 2.4 cps/mrem/h and is essentially nondirectional in response. With correct bias setting the counter is insensitive to gamma exposure up to 200 r/h from Co-60.

  20. Radiation loading effect proportional chamber on the performances

    International Nuclear Information System (INIS)

    Alekseev, T.D.; Kalinina, N.A.; Karpukhin, V.V.; Kruglov, V.V.; Khazins, D.M.

    1980-01-01

    The effect of a space charge which appears under the effect of radiation loading on counting characteristics of a proportional chamber, is experimentally investigated. Calculations are made which take into account the effect of a space charge of positive ions formed in the chamber. The investigations have been carried out on the test board which consists of a one-coordinate proportional chamber, a telescope of two scintillation counters and a collimated 90 Sr β-source. The proportional chamber has the 160x160 mm dimensions. The signal wires with the 50 μm diameter are located with the step of s=10 mm. High-voltage planes are coiled with a wire with the 100 μm diameter and a 2 mm step. The distance between high-voltage planes are 18 mm. The chamber is blown through with a gaseous mixture, its composition is 57% Ar+38% CH 4 +5% (OCH 3 ) 2 CH 2 . When carrying out measurements in wide ranges, the density of radiation loading and the amplifier threshold are changed. The experimental results show a considerable effect of radiation loading and the value of amplifier threshold on the value of a counting characteristic. This should be taken into account when estimating the performance of a proportional chamber according to board testing using radioactive sources, as conditions for investigations are usually different from those of a physical experiment on an accelerator

  1. Systematic studies of small scintillators for new sampling calorimeter

    Indian Academy of Sciences (India)

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R & D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are ...

  2. Some history of liquid scintillator development at Los Alamos

    International Nuclear Information System (INIS)

    Ott, D.G.

    1979-01-01

    The early developments in liquid scintillation counting made at Los Alamos Scientific Laboratory are reviewed. Most of the work was under the direction of F.N. Hayes and included counter development and applications as well as synthesis and chemistry of liquid scintillators

  3. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples; Desempeno de dos centelleadores liquidos y optimizacion de un contador Wallac 1411 en la cuantificacion de tritio en muestras acuosas

    Energy Technology Data Exchange (ETDEWEB)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  4. Liquid scintillation solutions

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The liquid scintillation solution described includes a mixture of: a liquid scintillation solvent, a primary scintillation solute, a secondary scintillation solute, a variety of appreciably different surfactants, and a dissolving and transparency agent. The dissolving and transparency agent is tetrahydrofuran, a cyclic ether. The scintillation solvent is toluene. The primary scintillation solute is PPO, and the secondary scintillation solute is dimethyl POPOP. The variety of appreciably different surfactants is composed of isooctylphenol-polyethoxyethanol and sodium dihexyl sulphosuccinate [fr

  5. Role of hot electron transport in scintillators: A theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huihui [SZU-NUS Collaborative Innovation Center for Optoelectronic Science and Technology, Key Lab. of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen Univ. (China); Li, Qi [Physical Sciences Division, IBM TJ Watson Research Center, Yorktown Heights, NY (United States); Department of Computer Science, University of Illinois at Urbana-Champaign, Urbana, IL (United States); Lu, Xinfu; Williams, R.T. [Department of Physics, Wake Forest University, Winston Salem, NC (United States); Qian, Yiyang [College of Engineering and Applied Science, Nanjing University (China); Wu, Yuntao [Scintillation Materials Research Center, University of Tennessee, Knoxville, TN (United States)

    2016-10-15

    Despite recent intensive study on scintillators, several fundamental questions on scintillator properties are still unknown. In this work, we use ab-initio calculations to determine the energy dependent group velocity of the hot electrons from the electronic structures of several typical scintillators. Based on the calculated group velocities and optical phonon frequencies, a Monte-Carlo simulation of hot electron transport in scintillators is carried out to calculate the thermalization time and diffusion range in selected scintillators. Our simulations provide physical insights on a recent trend of improved proportionality and light yield from mixed halide scintillators. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Counter support for WA35

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    This assembly was equipped with 78 counters, each consisting of a lucite cone, to produce Cerenkov light, and a CsI scintillator plate of 3 mm thickness glued on the face of the cone. The experiment WA35 was set-up in the s1 beam (West Hall) by the Darmstadt-Heidelberg-Virginia-Warsaw Collaboration to measure angular distributions and multiplicities of pions and recoil protons produced by hadrons interacting in nuclei. (See Annual Report 1976 p. 39)

  7. Scintillating camera

    International Nuclear Information System (INIS)

    Vlasbloem, H.

    1976-01-01

    The invention relates to a scintillating camera and in particular to an apparatus for determining the position coordinates of a light pulse emitting point on the anode of an image intensifier tube which forms part of a scintillating camera, comprising at least three photomultipliers which are positioned to receive light emitted by the anode screen on their photocathodes, circuit means for processing the output voltages of the photomultipliers to derive voltages that are representative of the position coordinates; a pulse-height discriminator circuit adapted to be fed with the sum voltage of the output voltages of the photomultipliers for gating the output of the processing circuit when the amplitude of the sum voltage of the output voltages of the photomultipliers lies in a predetermined amplitude range, and means for compensating the distortion introduced in the image on the anode screen

  8. Scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1979-01-01

    A scintillator structure comprises at least one layer of transparent fused quartz with a phosphor coating on one or both sides adjacent to at least one transparent layer of epoxy resin which directs light from the phosphor to a detector. The phosphor layer may be formed from a powder optionally with a binder, a single crystal or a melt, or by evaporation or sintering. A plurality of multiple layers may be used or the structure tilted for greater absorption. The structure may be surrounded by another such structure optionally operating in cascade with the first. Many phosphors are specified. A scintillator structure comprises phosphor particles dispersed in epoxy resin or copoly imide-silicone and cast in a multi-compartment box with long sides transparent to X-rays and dividers opaque to X-rays. (UK)

  9. Scintillating fibres

    International Nuclear Information System (INIS)

    Nahnhauer, R.

    1990-01-01

    In the search for new detector techniques, scintillating fibre technology has already gained a firm foothold, and is a strong contender for the extreme experimental conditions of tomorrow's machines. Organized by a group from the Institute of High Energy Physics, Berlin-Zeuthen, a workshop held from 3-5 September in the nearby village of Blossin brought together experts from East and West, and from science and industry

  10. Scintillating fibres

    Energy Technology Data Exchange (ETDEWEB)

    Nahnhauer, R. [IHEP Zeuthen (Germany)

    1990-11-15

    In the search for new detector techniques, scintillating fibre technology has already gained a firm foothold, and is a strong contender for the extreme experimental conditions of tomorrow's machines. Organized by a group from the Institute of High Energy Physics, Berlin-Zeuthen, a workshop held from 3-5 September in the nearby village of Blossin brought together experts from East and West, and from science and industry.

  11. Sample oxidation for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kisieleski, W.E.; Buess, E.M.

    1976-01-01

    The general features of biological and medical investigations which are responsible for the demands such investigations place upon the design specifications of liquid scintillation counters and associated methodology are reviewed. Special emphasis is given to the oxidative technique for sample preparation

  12. Radiocarbon dating methods using benzene liquid scintillation

    International Nuclear Information System (INIS)

    Togashi, Shigeko; Matsumoto, Eiji

    1983-01-01

    The radiocarbon dating method using benzene liquid scintillation is reported in detail. The results of measurement of NBS oxalic acid agree with the recommended value, indicating that isotopic fractionation during benzene synthesis can be negligible. Ten samples which have been already measured by gas counter are dated by benzene liquid scintillation. There is no significant difference in age for the same sample between benzene liquid scintillation and gas counters. It is shown that quenching has to be corrected for the young sample. Memory effect in stainless steel reaction vessel can be removed by using an exchangeable inner vessel and by baking it in the air. Using this method, the oldest age that can be measured with 2.3 g carbon is 40,000 years B.P. (author)

  13. Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators

    International Nuclear Information System (INIS)

    Archambault, Louis; Arsenault, Jean; Gingras, Luc; Sam Beddar, A.; Roy, Rene; Beaulieu, Luc

    2005-01-01

    Scintillation dosimetry is a promising avenue for evaluating dose patterns delivered by intensity-modulated radiation therapy plans or for the small fields involved in stereotactic radiosurgery. However, the increase in signal has been the goal for many authors. In this paper, a comparison is made between plastic scintillating fibers and plastic scintillator. The collection of scintillation light was measured experimentally for four commercial models of scintillating fibers (BCF-12, BCF-60, SCSF-78, SCSF-3HF) and two models of plastic scintillators (BC-400, BC-408). The emission spectra of all six scintillators were obtained by using an optical spectrum analyzer and they were compared with theoretical behavior. For scintillation in the blue region, the signal intensity of a singly clad scintillating fiber (BCF-12) was 120% of that of the plastic scintillator (BC-400). For the multiclad fiber (SCSF-78), the signal reached 144% of that of the plastic scintillator. The intensity of the green scintillating fibers was lower than that of the plastic scintillator: 47% for the singly clad fiber (BCF-60) and 77% for the multiclad fiber (SCSF-3HF). The collected light was studied as a function of the scintillator length and radius for a cylindrical probe. We found that symmetric detectors with nearly the same spatial resolution in each direction (2 mm in diameter by 3 mm in length) could be made with a signal equivalent to those of the more commonly used asymmetric scintillators. With augmentation of the signal-to-noise ratio in consideration, this paper presents a series of comparisons that should provide insight into selection of a scintillator type and volume for development of a medical dosimeter

  14. Emulation workbench for position sensitive gaseous scintillation detectors

    International Nuclear Information System (INIS)

    Pereira, L.; Margato, L.M.S.; Morozov, A.; Solovov, V.; Fraga, F. A. F.

    2015-01-01

    Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design and optimization of such detectors are complex and time consuming tasks. Simulations, while being a powerful tool, strongly depend on the light transfer models and demand accurate knowledge of many parameters, which are often not available. Here we describe an alternative approach based on the experimental evaluation of a detector using an isotropic point-like light source with precisely controllable light emission properties, installed on a 3D positioning system. The results obtained with the developed setup at validation conditions, when the scattered light is strongly suppressed show good agreement with simulations

  15. Measurement and simulation of the neutron detection efficiency with a Pb-scintillating fiber calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Anelli, M; Bertolucci, S; Curceanu, C; Giovannella, S; Happacher, F; Iliescu, M; Martini, M; Miscetti, S [Laboratori Nazionali di Frascati, INFN (Italy); Battistoni, G [Sezione INFN di Milano (Italy); Bini, C; Zorzi, G De; Domenico, Adi; Gauzzi, P [Ubiversita degli Studi ' La Sapienza' e Sezine INFN di Roma (Italy); Branchini, P; Micco, B Di; Ngugen, F; Paseri, A [Universita degli di Studi ' Roma Tre' e Sezione INFN di Roma Tre (Italy); Ferrari, A [Fondazione CNAO, Milano (Italy); Prokfiev, A [Svedberg Laboratory, Uppsala University (Sweden); Fiore, S, E-mail: matteo.martino@inf.infn.i

    2009-04-01

    We have measured the overall detection efficiency of a small prototype of the KLOE PB-scintillation fiber calorimeter to neutrons with kinetic energy range [5,175] MeV. The measurement has been done in a dedicated test beam in the neutron beam facility of the Svedberg Laboratory, TSL Uppsala. The measurements of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 28% to 33%. This value largely exceeds the estimated {approx}8% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beam line has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented together with the first data to Monte Carlo comparison. The results show an overall neutron efficiency of about 35%. The reasons for such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.

  16. A gaseous scintillation counter filled with He{sup 3} for neutron spectrometry; Compteur a scintillateur gazeux rempli de {sup 3}He pour la spectrometrie des flux de neutrons; Gazovyj stsintillyatsionnyj schetchik napolnennyj He{sup 3} dlya spektrometrii potokov nejtronov; Contador de centelleador gaseoso cargado con helio-3 para la espectrometria neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Baldin, S A; Matveev, V V

    1962-04-15

    The paper describes a gas plant and gaseous scintillation counter, and gives the results of experiments on the recording and spectrometry of neutron beams using a gaseous scintillation counter filled with a mixture of 10% xenene and 90% helium-3 at an overall pressure of 20 ata. Data are given on the design of the gas plant, which makes it possible to operate the counter continuously over long periods of time, as well as providing the required gas mixtures at overall pressures of up to 60 atm and ensuring constant freedom of the gas from contamination. In addition, the paper presents the results of research on the counter's energy resolution and linearity at different energy levels and indicates its efficiency in gamma fields of intensity up to 3 r/h; the possibility of extending the working energy-range of gaseous scintillation counters filled with helium-3 is also considered. (author) [French] FLes auteurs decrivent un compteur a scintillateur gazeux ainsi que les resultats des experiences d'enregistrement et de spectrometrie des flux de neutrons qui ont ete faites au moyen d'un compteur a scintillateur gazeux rempli d'un melange de 10% de xenon et de 90% d'helium-3 sous une pression de 20 atmospheres. Ils exposent les donnees relatives a la construction d'un appareillage qui assure le fonctionnement ininterrompu du compteur durant un laps de temps prolonge, l'obtention des melanges de gaz indispensables sous une pression totale de 60 atmospheres et l'epuration continue du gaz. En outre, ils examinent les resultats de l'etude du pouvoir de resolution en energie et de la linearite du compteur en fonction de l'energie, le fonctionnement du compteur dans les champs de rayonnement gamma d'une intensite allant jusqu'a 3 r/h, ainsi que la possibilite d'elargir la gamme d'energie dans laquelle on peut employer des compteurs a scintillateurs gazeux de {sup 3}He. (author) [Spanish] En esta memoria se describe un aparato de suministro de gas y un contador de centelleador

  17. Sealed drift tube cosmic ray veto counters

    International Nuclear Information System (INIS)

    Rios, R.; Tatar, E.; Bacon, J.D.; Bowles, T.J.; Hill, R.; Green, J.A.; Hogan, G.E.; Ito, T.M.; Makela, M.; Morris, C.L.; Mortenson, R.; Pasukanics, F.E.; Ramsey, J.; Saunders, A.; Seestrom, S.J.; Sondheim, W.E.; Teasdale, W.; Saltus, M.; Back, H.O.; Cottrell, C.R.

    2011-01-01

    We describe a simple drift tube counter that has been used as a cosmic ray veto for the UCNA experiment, a first-ever measurement of the neutron beta-asymmetry using ultra-cold neutrons. These detectors provide an inexpensive alternative to more conventional scintillation detectors for large area cosmic ray anticoincidence detectors.

  18. Silicon photomultipliers for scintillating trackers

    Energy Technology Data Exchange (ETDEWEB)

    Rabaioli, S., E-mail: simone.rabaioli@gmail.com [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); Berra, A.; Bolognini, D. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Bonvicini, V. [INFN sezione di Trieste (Italy); Bosisio, L. [Universita degli Studi di Trieste and INFN sezione di Trieste (Italy); Ciano, S.; Iugovaz, D. [INFN sezione di Trieste (Italy); Lietti, D. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Penzo, A. [INFN sezione di Trieste (Italy); Prest, M. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Rashevskaya, I.; Reia, S. [INFN sezione di Trieste (Italy); Stoppani, L. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); Vallazza, E. [INFN sezione di Trieste (Italy)

    2012-12-11

    In recent years, silicon photomultipliers (SiPMs) have been proposed as a new kind of readout device for scintillating detectors in many experiments. A SiPM consists of a matrix of parallel-connected pixels, which are independent photon counters working in Geiger mode with very high gain ({approx}10{sup 6}). This contribution presents the use of an array of eight SiPMs (manufactured by FBK-irst) for the readout of a scintillating bar tracker (a small size prototype of the Electron Muon Ranger detector for the MICE experiment). The performances of the SiPMs in terms of signal to noise ratio, efficiency and time resolution will be compared to the ones of a multi-anode photomultiplier tube (MAPMT) connected to the same bars. Both the SiPMs and the MAPMT are interfaced to a VME system through a 64 channel MAROC ASIC.

  19. Silicon photomultipliers for scintillating trackers

    Science.gov (United States)

    Rabaioli, S.; Berra, A.; Bolognini, D.; Bonvicini, V.; Bosisio, L.; Ciano, S.; Iugovaz, D.; Lietti, D.; Penzo, A.; Prest, M.; Rashevskaya, I.; Reia, S.; Stoppani, L.; Vallazza, E.

    2012-12-01

    In recent years, silicon photomultipliers (SiPMs) have been proposed as a new kind of readout device for scintillating detectors in many experiments. A SiPM consists of a matrix of parallel-connected pixels, which are independent photon counters working in Geiger mode with very high gain (∼106). This contribution presents the use of an array of eight SiPMs (manufactured by FBK-irst) for the readout of a scintillating bar tracker (a small size prototype of the Electron Muon Ranger detector for the MICE experiment). The performances of the SiPMs in terms of signal to noise ratio, efficiency and time resolution will be compared to the ones of a multi-anode photomultiplier tube (MAPMT) connected to the same bars. Both the SiPMs and the MAPMT are interfaced to a VME system through a 64 channel MAROC ASIC.

  20. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1977-01-01

    A liquid scintillation solution is described which includes (1) a scintillation solvent (toluene and xylene), (2) a primary scintillation solute (PPO and Butyl PBD), (3) a secondary scintillation solute (POPOP and Dimethyl POPOP), (4) a plurality of substantially different surfactants and (5) a filter dissolving and/or transparentizing agent. 8 claims

  1. Scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Swank, R.K.; White, P.J.

    1978-01-01

    Scintillator structures are described in which the phosphor is embedded or suspended in an optically transparent matrix which is selected or adjusted to have an index of refraction which is approximately equal to that of the phosphor at the wavelength of the light emitted by the phosphor. The matrix may be glass, copoly 2-vinyl naphthalene/vinyl toluene or a liquid e.g. Br-naphthalene and optionally CH 3 I, the ratio of components being adjusted to give the desired refractive index. The polymer may be made in situ or a mixture of phosphor and polymer formed e.g. by freeze drying a solution and pulverizing, and then heating. Specified dyes may be used for converting the emitted light to other wavelengths. (author)

  2. A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors

    International Nuclear Information System (INIS)

    Gamage, Kelum A.A.; Joyce, Malcolm J.; Cave, Frank D.

    2013-06-01

    Neutron coincidence counting is an established, nondestructive method for the qualitative and quantitative analysis of nuclear materials. Several even-numbered nuclei of the actinide isotopes, and especially even-numbered plutonium isotopes, undergo spontaneous fission, resulting in the emission of neutrons which are correlated in time. The characteristics of this i.e. the multiplicity can be used to identify each isotope in question. Similarly, the corresponding characteristics of isotopes that are susceptible to stimulated fission are somewhat isotope-related, and also dependent on the energy of the incident neutron that stimulates the fission event, and this can hence be used to identify and quantify isotopes also. Most of the neutron coincidence counters currently used are based on 3 He gas tubes. In the 3 He-filled gas proportional-counter, the (n, p) reaction is largely responsible for the detection of slow neutrons and hence neutrons have to be slowed down to thermal energies. As a result, moderator and shielding materials are essential components of many systems designed to assess quantities of fissile materials. The use of a moderator, however, extends the die-away time of the detector necessitating a larger coincidence window and, further, 3 He is now in short supply and expensive. In this paper, a simulation based on the Monte Carlo method is described which has been performed using MCNPX 2.6.0, to model the geometry of a sector-shaped liquid scintillation detector in response to coincident neutron events. The detection of neutrons from a mixed-oxide (MOX) fuel pellet using an organic liquid scintillator has been simulated for different thicknesses of scintillators. In this new neutron detector, a layer of lead has been used to reduce the gamma-ray fluence reaching the scintillator. The effect of lead for neutron detection has also been estimated by considering different thicknesses of lead layers. (authors)

  3. Energy resolution of scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Moszyński, M., E-mail: M.Moszynski@ncbj.gov.pl; Syntfeld-Każuch, A.; Swiderski, L.; Grodzicka, M.; Iwanowska, J.; Sibczyński, P.; Szczęśniak, T.

    2016-01-01

    According to current knowledge, the non-proportionality of the light yield of scintillators appears to be a fundamental limitation of energy resolution. A good energy resolution is of great importance for most applications of scintillation detectors. Thus, its limitations are discussed below; which arise from the non-proportional response of scintillators to gamma rays and electrons, being of crucial importance to the intrinsic energy resolution of crystals. The important influence of Landau fluctuations and the scattering of secondary electrons (δ-rays) on intrinsic resolution is pointed out here. The study on undoped NaI and CsI at liquid nitrogen temperature with a light readout by avalanche photodiodes strongly suggests that the non-proportionality of many crystals is not their intrinsic property and may be improved by selective co-doping. Finally, several observations that have been collected in the last 15 years on the influence of the slow components of light pulses on energy resolution suggest that more complex processes are taking place in the scintillators. This was observed with CsI(Tl), CsI(Na), ZnSe(Te), and undoped NaI at liquid nitrogen temperature and, finally, for NaI(Tl) at temperatures reduced below 0 °C. A common conclusion of these observations is that the highest energy resolution, and particularly intrinsic resolution measured with the scintillators, characterized by two or more components of the light pulse decay, is obtainable when the spectrometry equipment integrates the whole light of the components. In contrast, the slow components observed in many other crystals degrade the intrinsic resolution. In the limiting case, afterglow could also be considered as a very slow component that spoils the energy resolution. The aim of this work is to summarize all of the above observations by looking for their origin.

  4. Pulse shape discrimination with scintillation detectors

    International Nuclear Information System (INIS)

    Winyard, R.A.

    A quantitative study of pulse shape discrimination with scintillation counters has been undertaken using a crossover timing technique. The scintillators investigated included experimental and commercial liquids and plastics in addition to inorganic phosphors. The versatility of the pulse shape discrimination system has been demonstrated by extending the measurements to investigate phoswiches and liquids loaded with radioactive materials and by its application to the suppression of unwanted backgrounds in delayed coincidence counting for the measurement of nuclear half-lives and isotope identification have been carried out. (author)

  5. Production of the Large-area Plastic Scintillator for Beta-ray Detection using Epoxy Resin

    International Nuclear Information System (INIS)

    Nam, Jong Soo; Choi, Yong Seok; Hong, Sang Bum; Seo, Bum Kyung; Moon, Jei Kwon; Choi, Jong Won

    2016-01-01

    In this study, we prepared a plastic scintillator whose manufacturing process is simple and can be freely shaped. A thin plate of the plastic scintillator was manufactured using epoxy resin as a polymer. The plastic scintillator was made by mixing epoxy resin and organic scintillators under various conditions. The optimal mixture ratio to prepare the plastic scintillator was derived from the above results. Using the derived results, we made the large-area plastic scintillator which can quickly measure the contamination site and evaluated characteristics of the large-area plastic scintillator in the laboratory. A thin plate of a plastic scintillator with a simple preparation process can be freely shaped using epoxy resin and organic scintillators such as PPO and POPOP. PPO emits scintillation of light in the ultraviolet range, and POPOP is a wave shifter for moving the wavelength responsible for the PMT. The mixture ratio of PPO and POPOP was determined using their emission spectra. The optimal weight percentage of PPO and POPOP in an organic scintillator was determined to be 0.2 wt%:0.01 wt%. Based on the above results, the large-area plastic scintillator of the window size of a typical pancake-type αβ surface contamination counter was prepared. We want to evaluate the characteristics of the large-area plastic scintillator. However, there were the difficulties in evaluating characteristics of the large-area plastic scintillator. The cross-sectional area of the large-area plastic scintillator is significantly different to PMT

  6. Production of the Large-area Plastic Scintillator for Beta-ray Detection using Epoxy Resin

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jong Soo; Choi, Yong Seok; Hong, Sang Bum; Seo, Bum Kyung; Moon, Jei Kwon; Choi, Jong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this study, we prepared a plastic scintillator whose manufacturing process is simple and can be freely shaped. A thin plate of the plastic scintillator was manufactured using epoxy resin as a polymer. The plastic scintillator was made by mixing epoxy resin and organic scintillators under various conditions. The optimal mixture ratio to prepare the plastic scintillator was derived from the above results. Using the derived results, we made the large-area plastic scintillator which can quickly measure the contamination site and evaluated characteristics of the large-area plastic scintillator in the laboratory. A thin plate of a plastic scintillator with a simple preparation process can be freely shaped using epoxy resin and organic scintillators such as PPO and POPOP. PPO emits scintillation of light in the ultraviolet range, and POPOP is a wave shifter for moving the wavelength responsible for the PMT. The mixture ratio of PPO and POPOP was determined using their emission spectra. The optimal weight percentage of PPO and POPOP in an organic scintillator was determined to be 0.2 wt%:0.01 wt%. Based on the above results, the large-area plastic scintillator of the window size of a typical pancake-type αβ surface contamination counter was prepared. We want to evaluate the characteristics of the large-area plastic scintillator. However, there were the difficulties in evaluating characteristics of the large-area plastic scintillator. The cross-sectional area of the large-area plastic scintillator is significantly different to PMT.

  7. Liquid scintillation counting (LSC) - an overview

    International Nuclear Information System (INIS)

    Ravi, S.; Mathew, K.M.

    2005-01-01

    In Liquid Scintillation Counting, the amount of light produced is proportional to the amount of radiation present in the sample and the energy of the light produced is proportional to the energy of the radiation that is present in the sample. This makes LSC a very convenient tool to measure radioactivity

  8. Scintillating fiber detector performance, detector geometries, trigger, and electronics issues for scintillating fiber tracking

    International Nuclear Information System (INIS)

    Baumbaugh, A.E.

    1994-06-01

    Scintillating Fiber tracking technology has made great advances and has demonstrated great potential for high speed charged particle tracking and triggering. The small detector sizes and fast scintillation fluors available make them very promising for use at high luminosity experiments at today's and tomorrow's colliding and fixed target experiments where high rate capability is essential. This talk will discuss the current state of Scintillating fiber performance and current Visual Light Photon Counter (VLPC) characteristics. The primary topic will be some of the system design and integration issues which should be considered by anyone attempting to design a scintillating fiber tracking system which includes a high speed tracking trigger. Design. constraints placed upon the detector system by the electronics and mechanical sub-systems will be discussed. Seemingly simple and unrelated decisions can have far reaching effects on overall system performance. SDC and DO example system designs will be discussed

  9. Charged particle scintillation mass spectrometer

    International Nuclear Information System (INIS)

    Baranov, P.S.; Zhuravlev, E.E.; Nafikov, A.A.; Osadchi , A.I.; Raevskij, V.G.; Smirnov, P.A.; Cherepnya, S.N.; Yanulis, Yu.P.

    1982-01-01

    A scintillation mass-spectrometer for charged particle identification by the measured values of time-of-flight and energy operating on line with the D-116 computer is described. Original time detectors with 100x100x2 mm 3 and 200x2 mm 2 scintillators located on the 1- or 2 m path length are used in the spectrometer. The 200x200x200 mm 3 scintillation unit is used as a E-counter. Time-of-flight spectra of the detected particles on the 2 m path length obtained in spectrometer test in the beam of charged particles escaping from the carbon target at the angle of 130 deg under 1.2 GeV bremsstrahlung beam of the ''Pakhra'' PIAS synchrotron are presented. Proton and deuteron energy spectra as well as mass spectrum of all the particles detected by the spectrometer are given. Mass resolution obtained on the 2 m path length for π-mesons is +-25%, for protons is +-5%, for deuterons is +-3%

  10. Improved terbium-doped, lithium-loaded glass scintillator fibers

    International Nuclear Information System (INIS)

    Spector, G.B.; McCollum, T.; Spowart, A.R.

    1993-01-01

    An improved terbium-doped, 6 Li-loaded glass scintillator has been drawn into fibers. Tests indicate that the neutron detection response of the fibers is superior to the response with fibers drawn from the original terbium-doped glass. The new fibers offer less attenuation (1/e length of ∝40 cm) and improved gamma ray/neutron discrimination. The improved fibers will be incorporated in a scintillator fiber optic long counter for neutron detection. (orig.)

  11. Optics study of liquid scintillation counting systems

    International Nuclear Information System (INIS)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-01-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  12. The MICE scintillating-fibre tracker

    Energy Technology Data Exchange (ETDEWEB)

    Matsushita, T [Imperial College London (United Kingdom)], E-mail: T.Matsushita@imperial.ac.uk

    2008-06-15

    The international Muon Ionization Cooling Experiment (MICE) collaboration will carry out a systematic investigation of the ionization cooling of a muon beam. An ionization cooling channel is required to compress the phase-space volume occupied by the muon beam prior to acceleration in the baseline conceptual designs for both the Neutrino Factory and the Muon Collider. Muons entering and leaving the cooling channel will be measured in two solenoidal spectrometers, each of which is instrumented with a scintillating-fibre tracker. Each tracker is composed of five planar scintillating fibre stations, each station being composed of three planar layers of 350 micron scintillating fibres. The devices will be read out using the Visible Light Photon Counters (VLPCs) developed for use in the D0 experiment at the Tevatron. The design of the system will be presented along with the status of the tracker-construction project. The expected performance of prototypes of the full tracker will be summarised.

  13. Testing of the scintillation sandwich prototype

    International Nuclear Information System (INIS)

    Vashkevich, V.

    1995-06-01

    The 3 m 2 prototype of the surface detector using optical fiber readout was completely prepared for testing measurements in February 1995 at Fermilab. Two 25 mm thick, 3 m 2 acrylic scintillation plates (1.2 x 2.5 m 2 ) are used for light collection in the upper (above the 25 mm steel plate) and lower (below the steel) counters of the sandwich. The light is collected with the help of 1 mm diameter wavelength shifter fiber loops 3 m long inserted in the grooves on the top surface of the scintillator, 3 fibers per groove. We used Kurary Y11, 200 ppm of shifter dye, and double clad fibers. 1.5 m of clear fibers spliced to each end of the shifter fiber transport the light to the phototube. Spacing between the grooves is 5 cm. The counter's edges were painted with BICRON (BC620) white reflective paint. The scintillation plates were wrapped with Dupont Tyvek. The glued bundle of fibers is connected to an EMI-9902KB 38 mm phototube through the simple light mixer bar. Used PM has a ''green extended'' rubidium bialkali photocathode. The report contains information on the testing of the scintillation sandwich

  14. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The invention deals with a liquid scintillation solution which contains 1) a scintillation solvent (toluol), 2) a primary scintillation solute (PPO), 3) a secondary scintillation solute (dimethyl POPOP), 4) several surfactants (iso-octyl-phenol polyethoxy-ethanol and sodium di-hexyl sulfosuccinate) essentially different from one another and 5) a filter resolution and/or transparent-making agent (cyclic ether, especially tetrahydrofuran). (HP) [de

  15. Body counter

    International Nuclear Information System (INIS)

    Koeppe, P.

    1975-01-01

    The paper gives a survey on some applications of the whole body counter in clinical practice and a critical study of its application as a routine testing method. Remarks on the necessary precautions are followed by a more detailed discussion of the determination of the natural potassium content, the iron metabolism, the vitamin B12 test, investigations of the metabolism of the bone using 47 Ca and 85 Sr, investigations with iodine and iodine-labelled substances, clearance investigations (in particular the 51 Cr EDTA clearance test), as well as the possibilities of neutron activation in vivo. (ORU/AK) [de

  16. Scintillator manufacture at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Mellott, K.; Bross, A.; Pla-Dalmau, A.

    1998-08-01

    A decade of research into plastic scintillation materials at Fermilab is reviewed. Early work with plastic optical fiber fabrication is revisited and recent experiments with large-scale commercial methods for production of bulk scintillator are discussed. Costs for various forms of scintillator are examined and new development goals including cost reduction methods and quality improvement techniques are suggested.

  17. WORKSHOP: Scintillating fibre detectors

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Scintillating fibre detector development and technology for the proposed US Superconducting Supercollider, SSC, was the subject of a recent workshop at Fermilab, with participation from the high energy physics community and from industry. Sessions covered the current status of fibre technology and fibre detectors, new detector applications, fluorescent materials and scintillation compositions, radiation damage effects, amplification and imaging structures, and scintillation fibre fabrication techniques

  18. Liquid scintillation measurement. I

    International Nuclear Information System (INIS)

    Rexa, R.; Tykva, R.

    1983-01-01

    The individual components of scintillation solutions and their tasks are listed. Explained briefly is the scintillation process in a liquid scintillator. Factors are discussed which influence this process as are methods applied to supress their influence. They include: ionization quenching, quenching by dilution and concentration, chemical, colour, phase and photon quenching and single-photon events causing an undesirable backgorund. (M.D.)

  19. Scintillation response of organic and inorganic scintillators

    CERN Document Server

    Papadopoulos, L M

    1999-01-01

    A method to evaluate the scintillation response of organic and inorganic scintillators to different heavy ionizing particles is suggested. A function describing the rate of the energy consumed as fluorescence emission is derived, i.e., the differential response with respect to time. This function is then integrated for each ion and scintillator (anthracene, stilbene and CsI(Tl)) to determine scintillation response. The resulting scintillation responses are compared to the previously reported measured responses. Agreement to within 2.5% is observed when these data are normalized to each other. In addition, conclusions regarding the quenching parameter kB dependence on the type of the particle and the computed values of kB for certain ions are included. (author)

  20. Development of extruded resistive plastic tubes for proportional chamber cathodes

    International Nuclear Information System (INIS)

    Kondo, K.

    1982-01-01

    Carbon mixed plastic tubes with resistivity of 10 3 approx. 10 4 Ωcm have been molded with an extrusion method and used for the d.c. cathode of a proportional counter and a multi-wire proportional chamber. The signal by gas multiplication was picked up from a strip r.f. cathode set outside the tube. The characteristics of the counter in the proportional and limited streamer modes have been studied

  1. Elpasolite scintillators.

    Energy Technology Data Exchange (ETDEWEB)

    Doty, F. Patrick; Zhou, Xiao Wang; Yang, Pin; Rodriguez, Mark A

    2012-12-01

    This work was funded by the U.S. Department of Energy Office of Nonproliferation Research to develop elpasolite materials, with an emphasis on high-atomic-number rare-earth elpasolites for gamma-ray spectrometer applications. Low-cost, high-performance gamma-ray spectrometers are needed for detection of nuclear proliferation. Cubic materials, such as some members of the elpasolite family (A2BLnX6; Ln-lanthanide and X-halogen), hold promise due to their high light output, proportionality, and potential for scale-up. Using both computational and experimental studies, a systematic investigation of the compositionstructureproperty relationships of these high-atomic-number elpasolite halides was performed. The results reduce the barrier to commercialization of large single crystals or transparent ceramics, and will facilitate economical scale-up of elpasolites for high-sensitivity gamma-ray spectroscopy.

  2. Large Area X-Ray Proportional Counter (LAXPC) Instrument on ...

    Indian Academy of Sciences (India)

    P. C. Agrawal

    2017-06-19

    Jun 19, 2017 ... high time resolution X-ray observations in 3–80 keV energy band with moderate energy ... able to detect low-and high-frequency QPOs (up ... black hole binaries will provide a tool to probe .... cessed for pulse height analysis.

  3. Operation and application of tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Gerdung, S.; Roos, H.

    1995-01-01

    The application of TEPCs during the past decades in dosimetry, radiation protection and radiation therapy has revealed their large potential but also the necessity of careful operation. This paper reviews the experience gathered in the past and summarises the experimental procedures to ensure proper TEPC operation. The measurement system is described including detector, electronics and quality assurance. The pulse height analysis and its interpretation in terms of microdosimetric spectra and mean values are presented as well as the variance method. On the basis of these evaluation procedures, the second part of the paper presents some typical examples of TEPC applications: dose spectrometry, time-of-flight techniques and the measurement of dose equivalent quantities. Special attention is paid to possible extensions but also to limitations of the use of TEPCs in the various fields of application. (Author)

  4. Development of a honeycomb gas proportional counter array for ...

    Indian Academy of Sciences (India)

    channels, (e) the technology should be amenable to modular design with a minimum of dead space .... contents) of all the affected cells in a cluster. ... the Department of Science and Technology of the Government of India and the CERN PPE.

  5. Method for discriminating microphonic noise in proportional counters

    International Nuclear Information System (INIS)

    Gold, R.

    1991-01-01

    This patent describes a detector system responsive to nuclear events for installation in a downhole logging tool including measuring well drilling equipment which subjects the detection system to microphonic shock. It comprises a closed chamber subject to impinging nuclear events and having two separate anode wires therein spaced apart from each other and spanning the chamber, providing a pair of separated spaced output terminals to thereby form an output signal; circuit means connecting from at least one of the chamber output terminals to a different amplifier means having two input terminals; the circuit means connected from the output terminal of the chamber to one of the input terminals of the differential amplifier means to cause formation of an output signal from the differential amplifier means; and vibration shock responsive means mounted in the detector system and having an output terminal which forms an output signal for connection to a second input at the differential circuit means so that microphonic signals from the chamber and the shock responsive means are provided thereto and tend to cancel when applied to the input terminals thereof, and wherein the shock responsive means does not cancel at the differential circuit means signals relating to nuclear events from the detector system

  6. Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Deyglun, C.; Simony, B.; Perot, B.; Carasco, C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); Saurel, N.; Colas, S. [CEA, DAM, Valduc, F-21120 Is-sur-Tille (France); Collot, J. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Grenoble Alpes, CNRS/IN2P3, Grenoble (France)

    2015-07-01

    The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a

  7. Recoil-proton fast-neutron counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R. (Padua Univ. (Italy). Ist. di Fisica); Galeazzi, G.; Bressanini, G.

    1981-12-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  8. Recoil-proton fast-neutron-counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Galeazzi, G.; Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Bressanini, G.

    1981-01-01

    A proton-recoil neutron counter telescope is described composed of a solid state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time-of-flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV, presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  9. A recoil-proton fast-neutron counter telescope

    International Nuclear Information System (INIS)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Galeazzi, G.; Bressanini, G.

    1981-01-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV. (author)

  10. 'Miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Artikov, A.

    2006-01-01

    Full text: Muon detection is fundamental for the most of the interesting analyses at CDF. At the course of Run II, the collaboration expects to collect hundreds of t t-bar decays yielding a muon as well as several million B-hadron events involving J/ψ → μ + μ - decays. Muon detection is also of fundamental importance in the study of W-boson properties and in the search for Higgs production associated with W or Z bosons. Considerable effort therefore went into extending the muon detector coverage for Run II, which started in March 2001. The CDF II muon detector system consists of multiple layers of drift chambers and scintillation counters, which span the pseudorapidity (|η|) range between 0 and 1.5. Detectors spanning different ranges have different geometries, and the muon scintillation counter system includes subsystems in the regions that have come to be known as the 'central' (0 pe for WLS fiber readout is smaller than for conventional readout, we can also expect an increase in the statistical contribution to the overall uncertainty. Our first concern, before adopting this solution, was therefore to ascertain that the mean timing resolution obtained under these conditions was adequate. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of MSX' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns. (author)

  11. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  12. New shaper of scintillation signals

    International Nuclear Information System (INIS)

    Brovchenko, V.G.

    2001-01-01

    Summation of the exponential shape pulse (abrupt front, exponential fall-off) with the pulse, proportional to its integral (the integration time constant is equal to the exponent fall-off constant), results in the pulse, the apex whereof is horizontal (parallel to the base line). Such a pulse is suitable for registration through standard analog-to-digital converters of the consecutive binary approximation, The described scheme is accomplished for verification of the basic principle of the shaper action. The parameters of the scheme are approximated to those ones, necessary for processing scintillation signals NaI(Tl) [ru

  13. Semiconductor high-energy radiation scintillation detector

    International Nuclear Information System (INIS)

    Kastalsky, A.; Luryi, S.; Spivak, B.

    2006-01-01

    We propose a new scintillation-type detector in which high-energy radiation generates electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The key issue is how to make the semiconductor essentially transparent to its own infrared light, so that photons generated deep inside the semiconductor could reach its surface without tangible attenuation. We discuss two ways to accomplish this, one based on doping the semiconductor with shallow impurities of one polarity type, preferably donors, the other by heterostructure bandgap engineering. The proposed semiconductor scintillator combines the best properties of currently existing radiation detectors and can be used for both simple radiation monitoring, like a Geiger counter, and for high-resolution spectrography of the high-energy radiation. An important advantage of the proposed detector is its fast response time, about 1 ns, essentially limited only by the recombination time of minority carriers. Notably, the fast response comes without any degradation in brightness. When the scintillator is implemented in a qualified semiconductor material (such as InP or GaAs), the photo-detector and associated circuits can be epitaxially integrated on the scintillator slab and the structure can be stacked-up to achieve virtually any desired absorption capability

  14. Possibility of experiments using radiation counters for test electron stability and Pauli principle violation in atoms

    International Nuclear Information System (INIS)

    Barabash, A.S.

    1989-01-01

    Capabilities of modern radiation detectors for investigation into electron stability and possible violation of Pauli principle in atoms are discussed. For experimental searches of electron instability the following low-background devices are used: scintillation NaI-detectors, semiconducting detectors of enriched germanium, emission chamber, multisection proportional counter and low-temperature detectors. It is ascertained that using modern low-background devices applying the earlier enumerated detectors, it is possible to achieve sensitivity of the order of 10 24 -10 25 years for the electron lifetime relatively to its decay and Pauli principle violation in atoms. Experiments with sensitivity of ∼ 10 26 -10 27 can be realized in massive low-temperature detectors, developed for neutrino physics. 28 refs; 1 fig

  15. Primary 4πβ-γ coincidence system for standardization of radionuclides by means of plastic scintillators

    International Nuclear Information System (INIS)

    Baccarelli, Aida Maria

    2003-01-01

    The present work describes a 4π(α,β)-γ coincidence system for absolute measurement of radionuclide activity using a plastic scintillator in 4π geometry for charged particles detection and a Nal (Tl) crystal for gamma-ray detection. Several shapes and dimensions of the plastic scintillator have been tried in order to obtain the best system configuration. Radionuclides which decay by alpha emission, β - , β + and electron capture have been standardized. The results showed excellent agreement with other conventional primary system which makes use of a 4π proportional counter for X-ray and charged particle detection. The system developed in the present work have some advantages when compared with the conventional systems, namely; it does not need metal coating on the films used as radioactive source holders. When compared to liquid scintillators, is showed the advantage of not needing to be kept in dark for more than 24 h to allow phosphorescence decay of ambient light. Therefore it can be set to count immediately after the sources are placed inside of it. (author)

  16. Scintillator material. Szintillatormaterial

    Energy Technology Data Exchange (ETDEWEB)

    Siegmund, M; Bendig, J; Regenstein, W

    1987-11-25

    A scintillator material for detection and quantitative determination of ionizing radiation is discussed consisting of an acridone dissolved in a fluid or solid medium. Solvent mixtures with at least one protogenic component or polymers and copolymers are used. The scintillator material is distinguished by an excellent stability at high energy doses.

  17. Numerical model of thyroid counter

    Directory of Open Access Journals (Sweden)

    Szuchta Maciej

    2016-03-01

    Full Text Available The aim of this study was to develop a numerical model of spectrometric thyroid counter, which is used for the measurements of internal contamination by in vivo method. The modeled detector is used for a routine internal exposure monitoring procedure in the Radiation Protection Measurements Laboratory of National Centre for Nuclear Research (NCBJ. This procedure may also be used for monitoring of occupationally exposed nuclear medicine personnel. The developed model was prepared using Monte Carlo code FLUKA 2011 ver. 2b.6 Apr-14 and FLAIR ver. 1.2-5 interface. It contains a scintillation NaI(Tl detector, the collimator and the thyroid water phantom with a reference source of iodine 131I. The geometry of the model was designed and a gamma energy spectrum of iodine 131I deposited in the detector was calculated.

  18. Distributed performance counters

    Science.gov (United States)

    Davis, Kristan D; Evans, Kahn C; Gara, Alan; Satterfield, David L

    2013-11-26

    A plurality of first performance counter modules is coupled to a plurality of processing cores. The plurality of first performance counter modules is operable to collect performance data associated with the plurality of processing cores respectively. A plurality of second performance counter modules are coupled to a plurality of L2 cache units, and the plurality of second performance counter modules are operable to collect performance data associated with the plurality of L2 cache units respectively. A central performance counter module may be operable to coordinate counter data from the plurality of first performance counter modules and the plurality of second performance modules, the a central performance counter module, the plurality of first performance counter modules, and the plurality of second performance counter modules connected by a daisy chain connection.

  19. Proportionality for Military Leaders

    National Research Council Canada - National Science Library

    Brown, Gary D

    2000-01-01

    .... Especially lacking is a realization that there are four distinct types of proportionality. In determining whether a particular resort to war is just, national leaders must consider the proportionality of the conflict (i.e...

  20. Production low cost plastic scintillator by using commercial polystyrene

    International Nuclear Information System (INIS)

    2011-01-01

    were produced with those determined parameters in 12 June 2008. Plastic blocks prepared were optically and mechanically tested and its response against various radioactive sources was measured. The results regarding the optical, mechanical and detection properties of blocks produced in 10x5x40 cm dimension were compared with commercial LODLUM Scintillator (main component PVT) produced by US in 13x8x120 cm dimensions. It was found that optical and mechanical properties of blocks produced in SANAEM are similar to or better than that of LODLUM. Plastic scintillator produced in SANAEM has shown the same response and counting characteristics that obtained by LODLUM, but proportional to its area and/or volume specifications. This study has shown that plastic scintillators imported can be produced in SANAEM domestically and be used for detection of radioactive materials within the country or border gates.

  1. Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    The Cherenkov counter described for use at Isabelle is a threshold counter in which light is focussed on phototubes. The counter is applicable in large-angle, small-aperture magnetic spectrometers for measurement of particle yields at large p/sub T/. Three of these counters will provide complete π-K-p separation in the range of 7-20 GeV/c. Other Cherenkov counters are discussed and a bibliography of relevant literature on the counters utilizing photoionization is included

  2. Pulse formation of gas-filled counter

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Teshima, Kazunori; Shizuma, Kiyoshi; Hasai, Hiromi

    1991-01-01

    The pulse formation of gas-filled counter has been calculated by simple models for the proportional and self-quenching streamer (SQS) modes. Calculated pulse shapes of counter output have accurately reproduced the observed ones for both modes. As a result, it is shown that the special density distribution of ion pairs in a streamer can be estimated with the rising part of observed pulse shape, using the model. (author)

  3. Single-photoelectron noise reduction in scintillation detectors

    International Nuclear Information System (INIS)

    Marvin, T.P.

    1995-10-01

    The 1994--95 search at SLAC for mulicharged particles used four 21 x 21 x 130-cm 3 Bicron 408 scintillation counters to detect a signal at the single-photoelectron level. The competing noise requiring minimization was due to a combination of PM tube (8-inch Thorne EMI 9353KA) afterpulsing and ambient radiation-induced scintillator luminescence. A very slow decay (> 30 μs) component was observed and received particular attention. Efforts to reduce the SPE noise included photomultiplier tube base modifications, detector shielding and cooling, signal amplification, and veto procedures

  4. Determination of thoron and radon ratio by liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Nakanishi, T.; Nakahara, H.

    2006-01-01

    A portable liquid scintillation counter was applied for the analysis of alpha-ray energy spectrum to determine the ratio of 220 Rn/ 222 Rn in fumarolic gas in the field. A surface-polished vial was developed, by which a Gaussian distribution could be approximated for the alpha-ray energy spectra and the peak areas of the nuclides could be estimated independently, because of the wide FWHM in the liquid scintillation pulse. A fumarolic gas sample was collected in Mt. Kamiyama (Hakoneyama geothermal field in Japan) having low 220 Rn/ 222 Rn ratio of 2.20 ± 0.13. (author)

  5. Radioactivity observed in scintillation counters during the HEAO-1 mission

    Science.gov (United States)

    Gruber, D. E.; Jung, G. V.; Matteson, J. L.

    1989-01-01

    Results are reported from an analysis of radioactivity induced in the NaI medium-energy detector of the hard X-ray and low-energy gamma-ray experiment during the HEAO-1 satellite mission (1977-1978). Consideration is given to the instrument characteristics, the origin and variability of background, and the separation of cosmic-ray activity from the internal activity due to South Atlantic Anomaly trapped protons. Energy spectra and tables listing the nuclide identifications are provided.

  6. Time-of-flight scintillator counters for S131

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    This experiment was carried out by a team from the University of Geneva to measure the production of strange bosons by positive and negative kaons in hydrogen. The photo shows Roger Schillsott working on the recoil-proton branch of the two-arm spectrometer.

  7. Real-time {sup 90}Sr Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi; Kobayashi, Atsushi; Tabata, Makoto; Ito, Hiroshi [Graduate School of Science, Chiba University, Chiba, (Japan); Han, Soorim [Graduate School of Science, Chiba University, Chiba, (Japan); National Institute of Radiological Science, Chiba, (Japan)

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray of maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower

  8. CEDAR counter (internal part)

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    Here on the mounting bench. The counter is a differential Cerenkov, corrected for chromaticity, able to differentiate pions from kaons up to 350 GeV. Counters of this type were used in all SPS hadron beams.

  9. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  10. Phosphor scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1980-01-01

    A method of fabricating scintillators is described in which the phosphor is distributed within the structure in such a way as to enhance the escape of the visible wavelength radiation that would otherwise be dissipated within the scintillator body. Two embodiments of the present invention are disclosed: one in which the phosphor is distributed in a layered structure and another in which the phosphor is dispersed throughout a transparent matrix. (U.K.)

  11. Scintillation Detector for the Measurement of Ultra-Heavy Cosmic Rays on the Super-TIGER Experiment

    Science.gov (United States)

    Link, Jason

    2011-01-01

    We discuss the design and construction of the scintillation detectors for the Super-TIGER experiment. Super-TIGER is a large-area (5.4sq m) balloon-borne experiment designed to measure the abundances of cosmic-ray nuclei between Z= 10 and Z=56. It is based on the successful TIGER experiment that flew in Antarctica in 2001 and 2003. Super-TIGER has three layers of scintillation detectors, two Cherenkov detectors and a scintillating fiber hodoscope. The scintillation detector employs four wavelength shifter bars surrounding the edges of the scintillator to collect the light from particles traversing the detector. PMTs are optically coupled at both ends of the bars for light collection. We report on laboratory performance of the scintillation counters using muons. In addition we discuss the design challenges and detector response over this broad charge range including the effect of scintilator saturation.

  12. Response of CsI:Pb Scintillator Crystal to Neutron Radiation

    Science.gov (United States)

    Costa Pereira, Maria da Conceição; Filho, Tufic Madi; Berretta, José Roberto; Náhuel Cárdenas, José Patrício; Iglesias Rodrigues, Antonio Carlos

    2018-01-01

    The helium-3 world crisis requires a development of new methods of neutron detection to replace commonly used 3He proportional counters. In the past decades, great effort was made to developed efficient and fast scintillators to detect radiation. The inorganic scintillator may be an alternative. Inorganic scintillators with much higher density should be selected for optimal neutron detection efficiency taking into consideration the relevant reactions leading to light emission. These detectors should, then, be carefully characterized both experimentally and by means of advanced simulation code. Ideally, the detector should have the capability to separate neutron and gamma induced events either by amplitude or through pulse shape differences. As neutron sources also generate gamma radiation, which can interfere with the measurement, it is necessary that the detector be able to discriminate the presence of such radiation. Considerable progress has been achieved to develop new inorganic scintillators, in particular increasing the light output and decreasing the decay time by optimized doping. Crystals may be found to suit neutron detection. In this report, we will present the results of the study of lead doped cesium iodide crystals (CsI:Pb) grown in our laboratory, using the vertical Bridgman technique. The concentration of the lead doping element (Pb) was studied in the range 5x10-4 M to 10-2 M . The crystals grown were subjected to annealing (heat treatment). In this procedure, vacuum of 10-6 mbar and continuous temperature of 350°C, for 24 hours, were employed. In response to neutron radiation, an AmBe source with energy range of 1 MeV to 12 MeV was used. The activity of the AmBe source was 1Ci Am. The fluency was 2.6 x 106 neutrons/second. The operating voltage of the photomultiplier tube was 1700 V; the accumulation time in the counting process was 600 s and 1800 s. The scintillator crystals used were cut with dimensions of 20 mm diameter and 10 mm height.

  13. Use of parallel counters for triggering

    International Nuclear Information System (INIS)

    Nikityuk, N.M.

    1991-01-01

    Results of investigation of using parallel counters, majority coincidence schemes, parallel compressors for triggering in multichannel high energy spectrometers are described. Concrete examples of methods of constructing fast and economic new devices used to determine multiplicity hits t>900 registered in a hodoscopic plane and a pixel detector are given. For this purpose the author uses the syndrome coding method and cellular arrays. In addition, an effective coding matrix has been created which can be used for light signal coding. For example, such signals are supplied from scintillators to photomultipliers. 23 refs.; 21 figs

  14. Scintillating properties of frozen new liquid scintillators

    CERN Document Server

    Britvich, G I; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    The light emission from scintillators which are liquid at room temperature was studied in the interval between $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C, where the phase transition from liquid to solid takes place. The light yield measured at $-120$~$^{\\circ}$C is about twice as much as that observed at $+20$~$^{\\circ}$C. By cooling the scintillator from $+20$~$^{\\circ}$C to $-120$~$^{\\circ}$C and then heating it from $-120$~$^{\\circ}$C to $+20$~$^{\\circ}$C, the light yield varies in steps at well defined temperatures, which are different for the cooling and heating processes. These hysteresis phenomena appear to be related to the solvent rather than to the dopant. The decay time of scintillation light was measured at $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C. Whilst at room temperature most of the light is emitted with a decay time of 6--8 ns, at $-120$~$^{\\circ}$C a slower component, with a decay time of 25--35 ns, becomes important.

  15. The fast trigger scintillator for the JETSET experiment (PS202/LEAR)

    International Nuclear Information System (INIS)

    Sefzick, T.

    1988-12-01

    In the present thesis the trigger detector of the JETSET experiment (PS202) at the LEAR/CERN consisting of scintillation counters is presented. After giving a start signal in a second stage of the trigger electronics the determination of the position of the traversed points of the reaction products is performed with the information of the scintillation detector. A third following trigger stage shall study the position informations given by the second stage under kinematical points of view. The present diploma thesis deals especially with the first two trigger stages. As basic conditions the components of a scintillation counter are treated and calibration and testing possibilities presented. For this belongs a fast light pulser with green or blue LED. Results of the studies which scintillator and light-guide materials are most suitable for the JETSET experiment are presented. (orig./HSI) [de

  16. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  17. Monte Carlo simulation of {beta}-{gamma} coincidence system using plastic scintillators in 4{pi} geometry

    Energy Technology Data Exchange (ETDEWEB)

    Dias, M.S. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)], E-mail: msdias@ipen.br; Piuvezam-Filho, H. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil); Baccarelli, A.M. [Departamento de Fisica-PUC/SP-Rua Marques de Paranagua 111, 01303-050 Sao Paulo, SP (Brazil); Takeda, M.N. [Universidade Santo Amaro, UNISA-Rua Prof. Eneas da Siqueira Neto 340, 04829-300 Sao Paulo, SP (Brazil); Koskinas, M.F. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)

    2007-09-21

    A modified version of a Monte Carlo code called Esquema, developed at the Nuclear Metrology Laboratory in IPEN, Sao Paulo, Brazil, has been applied for simulating a 4{pi}{beta}(PS)-{gamma} coincidence system designed for primary radionuclide standardisation. This system consists of a plastic scintillator in 4{pi} geometry, for alpha or electron detection, coupled to a NaI(Tl) counter for gamma-ray detection. The response curves for monoenergetic electrons and photons have been calculated previously by Penelope code and applied as input data to code Esquema. The latter code simulates all the disintegration processes, from the precursor nucleus to the ground state of the daughter radionuclide. As a result, the curve between the observed disintegration rate as a function of the beta efficiency parameter can be simulated. A least-squares fit between the experimental activity values and the Monte Carlo calculation provided the actual radioactive source activity, without need of conventional extrapolation procedures. Application of this methodology to {sup 60}Co and {sup 133}Ba radioactive sources is presented and showed results in good agreement with a conventional proportional counter 4{pi}{beta}(PC)-{gamma} coincidence system.

  18. Monte Carlo simulation of β-γ coincidence system using plastic scintillators in 4π geometry

    International Nuclear Information System (INIS)

    Dias, M.S.; Piuvezam-Filho, H.; Baccarelli, A.M.; Takeda, M.N.; Koskinas, M.F.

    2007-01-01

    A modified version of a Monte Carlo code called Esquema, developed at the Nuclear Metrology Laboratory in IPEN, Sao Paulo, Brazil, has been applied for simulating a 4πβ(PS)-γ coincidence system designed for primary radionuclide standardisation. This system consists of a plastic scintillator in 4π geometry, for alpha or electron detection, coupled to a NaI(Tl) counter for gamma-ray detection. The response curves for monoenergetic electrons and photons have been calculated previously by Penelope code and applied as input data to code Esquema. The latter code simulates all the disintegration processes, from the precursor nucleus to the ground state of the daughter radionuclide. As a result, the curve between the observed disintegration rate as a function of the beta efficiency parameter can be simulated. A least-squares fit between the experimental activity values and the Monte Carlo calculation provided the actual radioactive source activity, without need of conventional extrapolation procedures. Application of this methodology to 60 Co and 133 Ba radioactive sources is presented and showed results in good agreement with a conventional proportional counter 4πβ(PC)-γ coincidence system

  19. The Principle of Proportionality

    DEFF Research Database (Denmark)

    Bennedsen, Morten; Meisner Nielsen, Kasper

    2005-01-01

    Recent policy initiatives within the harmonization of European company laws have promoted a so-called "principle of proportionality" through proposals that regulate mechanisms opposing a proportional distribution of ownership and control. We scrutinize the foundation for these initiatives...... in relationship to the process of harmonization of the European capital markets.JEL classifications: G30, G32, G34 and G38Keywords: Ownership Structure, Dual Class Shares, Pyramids, EU companylaws....

  20. Development of a novel scintillation-trigger detector for the MTV experiment using aluminum-metallized film tapes

    Science.gov (United States)

    Tanaka, S.; Ozaki, S.; Sakamoto, Y.; Tanuma, R.; Yoshida, T.; Murata, J.

    2014-07-01

    A new type of a trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, which uses aluminum-metallized film tape for wrapping to achieve the required assembling precision of ±0.5 mm. The MTV experiment uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The barrel-type trigger counter is placed inside the CDC to generate a trigger signal using 1 mm thick, 300 mm long thin plastic scintillation counters. Detection efficiency and light attenuation compared with conventional wrapping materials are studied.

  1. Development of a novel scintillation-trigger detector for the MTV experiment using aluminum-metallized film tapes

    International Nuclear Information System (INIS)

    Tanaka, S.; Ozaki, S.; Sakamoto, Y.; Tanuma, R.; Yoshida, T.; Murata, J.

    2014-01-01

    A new type of a trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, which uses aluminum-metallized film tape for wrapping to achieve the required assembling precision of ±0.5 mm. The MTV experiment uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The barrel-type trigger counter is placed inside the CDC to generate a trigger signal using 1 mm thick, 300 mm long thin plastic scintillation counters. Detection efficiency and light attenuation compared with conventional wrapping materials are studied

  2. Azimuthal spread of the avalanche in proportional chambers

    International Nuclear Information System (INIS)

    Okuno, H.; Fischer, J.; Radeka, V.; Walenta, A.H.

    1978-10-01

    The angular distribution of the avalanche around the anode wire in the gas proportional counter is determined by measuring the distribution of positive ions arriving on cathode strips surrounding the anode wire for each single event. The shape and width of the distribution depend on such factors as the gas gain, the anode diameter, the counting gas and the primary ionization density. Effects of these factors are studied systematically, and their importance for practical counter applications is discussed

  3. Inorganic liquid scintillator

    International Nuclear Information System (INIS)

    Pavlicek, Z.; Barta, C.; Jursova, L.

    1986-01-01

    An inorganic liquid scintillator is designed which contains 1 to 30 wt.% of an inorganic molecular compound as the basic active component; the compound contains a cation with an atomic number higher than 47 and a halogen anion. The basic inorganic component is dissolved in water or in an organic solvent in form of non-dissociated molecules or self-complexes in which the bond is preserved between the cation and anion components. The light yield from these scintillators ranges between 70 and 150% of the light yield of a standard organic scintillator based on toluene. They are advantageous in that that they allow to increase the water content in the sample to up to 100%. (M.D.)

  4. Physics of scintillation detectors

    International Nuclear Information System (INIS)

    Novotny, R.

    1991-01-01

    The general concept of a radiation detector is based on three fundamental principles: sensitivity of the device to the radiation of interest which requires a large cross-section in the detector material, detector response function to the physical properties of the radiation. As an example, a scintillation detector for charged particles should allow to identify the charge of the particle, its kinetic energy and the time of impact combined with optimum resolutions. Optimum conversion of the detector response (like luminescence of a scintillator) into electronical signals for further processing. The following article will concentrate on the various aspects of the first two listed principles as far as they appear to be relevant for photon and charged particle detection using organic and inorganic scintillation detectors. (orig.)

  5. Scintillator plate calorimetry

    International Nuclear Information System (INIS)

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin

  6. Possibility of semiconductor counters application for internal contamination measurement of whole human body

    International Nuclear Information System (INIS)

    Cunic, O.; Orlic, M.; Bek-Uzarov, Dj.; Pavlovic, S.; Pavlovic, R.

    1997-01-01

    The possibility of high resolution semiconductor counters application in 'Vinca' Whole Body Counter for direct beta-gamma internal contamination measurement are discussed, assuming the following relevant characteristics: efficiency, resolution and counter price. A comparison with appropriate characteristics of NaI(Tl) crystal used in 'Vinca' WBC is treated. It is evident that the scintillation counters have the higher detection efficiency, but HPGe counters having much better resolution and recently lowest prices are also acceptable to join the existing NaI(Tl) counters with the HPGe counters in the same time, allow better spectral analyses of the human body activity and additionally more precise estimation of the equivalent doses rate which is generally a essential problem in WBC measurements. (author)

  7. Method for determination of radon-222 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-06-01

    The procedure for the determination of radon-222 by liquid scintillation counting is quite specific for this radionuclide. Radon-222 is extracted readily from the water sample by an organic scintillant. The decay products of radon-222 will remain in the water phase whilst radon-222 will be extracted into the organic phase. Before measurement the sample is stored for three hours until equilibrium is reached between radon-222 and its alpha emitting decay products. The alpha activity from radon-222 and its decay products is measured in a liquid scintillation counter

  8. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  9. Microfluidic Scintillation Detectors

    CERN Multimedia

    Microfluidic scintillation detectors are devices of recent introduction for the detection of high energy particles, developed within the EP-DT group at CERN. Most of the interest for such technology comes from the use of liquid scintillators, which entails the possibility of changing the active material in the detector, leading to an increased radiation resistance. This feature, together with the high spatial resolution and low thickness deriving from the microfabrication techniques used to manufacture such devices, is desirable not only in instrumentation for high energy physics experiments but also in medical detectors such as beam monitors for hadron therapy.

  10. Study of the correlation of scintillation decay and emission wavelength

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Fujimoto, Yutaka; Yamaji, Akihiro; Kawaguchi, Noriaki; Kamada, Kei; Totsuka, Daisuke; Fukuda, Kentaro; Yamanoi, Kohei; Nishi, Ryosuke; Kurosawa, Shunsuke; Shimizu, Toshihiko; Sarukura, Nobuhiko

    2013-01-01

    In photoluminescence which directly excites the emission center of phosphor material is known to have a correlation between the emission wavelength and the decay time based on quantum mechanics. In scintillation phenomenon, host lattice of the material is first excited by ionizing radiation and then the excitation energy is transferred to emission centers. For the first time, we investigated the correlation between the scintillation decay and the emission wavelength by using pulse X-ray equipped streak camera system which could observe time and wavelength resolved scintillation phenomenon. Investigated materials were Ce 3+ , Pr 3+ and Nd 3+ doped oxides and fluorides which all showed 5d-4f transition based emission. As a result, we obtained the relation that τ (scintillation decay time) was proportional to the λ 2.15 (emission wavelength). -- Highlights: ► The correlation between emission wavelength and scintillation decay time is investigated. ► Photoluminescence decay times are also evaluated and compared with scintillation decay times. ► It is proved the relaxation process in emission center is dominant even in scintillation decay

  11. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  12. Multimode pulse counter

    International Nuclear Information System (INIS)

    Natanzon, D.D.

    1982-01-01

    A pulse counter with code conversion is described. The counter is based on the integrated circuits of direct-counting devices of medium integration. The counter ensures various modes of pulse counting depending on the logical control signals: reversible, two-channel summing, one-channel summing binary, summing with ''storage'' signal code fixation without interrupting pulse counting. Arrangement of the suggested structure as a microcircuit of medium integration might contribute to reduction in the counter type nomenclature in digital families of widely used integrated circuits

  13. Scintillation properties of acrylate based plastic scintillator by photoploymerization method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hwan [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Lee, Joo Il [Dept. of of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima GoldTM LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380⁓520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400⁓ 800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

  14. Polysiloxane scintillator composition

    Science.gov (United States)

    Walker, J.K.

    1992-05-05

    A plastic scintillator useful for detecting ionizing radiation comprising a matrix which comprises an optically transparent polysiloxane having incorporated therein at least one ionizing radiation-hard fluor capable of converting electromagnetic energy produced in the polysiloxane upon absorption of ionizing radiation to detectable light.

  15. WORKSHOP: Scintillating crystals

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-12-15

    Scintillating crystals are one of the big spinoff success stories of particle physics, and from 22-26 September an international workshop in Chamonix in the French Alps looked at the increasing role of these materials in pure and applied science and in industry.

  16. Radiopharmaceuticals for bone scintillators

    International Nuclear Information System (INIS)

    Rey, A.M.

    1994-01-01

    One of the diagnostic techniques used in nuclear medicine is the bone scintiscanning with labelled compounds for obtain skeletal images. The main sections in this work are: (1) bone composition and anatomy;(2)skeletal radiopharmaceutical development;(3)physical properties of radionuclides;(4)biological behaviour and chemical structures;(5)radiopharmaceuticals production for skeletal scintillation;(6)kits;(7)dosimetry and toxicity.tabs

  17. WORKSHOP: Scintillating crystals

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Scintillating crystals are one of the big spinoff success stories of particle physics, and from 22-26 September an international workshop in Chamonix in the French Alps looked at the increasing role of these materials in pure and applied science and in industry

  18. Economical stabilized scintillation detector

    International Nuclear Information System (INIS)

    Anshakov, O.M.; Chudakov, V.A.; Gurinovich, V.I.

    1983-01-01

    An economical scintillation detector with the stabilization system of an integral type is described. Power consumed by the photomultiplier high-voltage power source is 40 mW, energy resolution is not worse than 9%. The given detector is used in a reference detector of a digital radioisotope densimeter for light media which is successfully operating for several years

  19. Uranium-scintillator device

    International Nuclear Information System (INIS)

    Smith, S.D.

    1979-01-01

    The calorimeter subgroup of the 1977 ISABELLE Summer Workshop strongly recommended investigation of the uranium-scintillator device because of its several attractive features: (1) increased resolution for hadronic energy, (2) fast time response, (3) high density (i.e., 16 cm of calorimeter per interaction length), and, in comparison with uranium--liquid argon detectors, (4) ease of construction, (5) simple electronics, and (6) lower cost. The AFM group at the CERN ISR became interested in such a calorimeter for substantially the same reasons, and in the fall of 1977 carried out tests on a uranium-scintillator (U-Sc) calorimeter with the same uranium plates used in their 1974 studies of the uranium--liquid argon (U-LA) calorimeter. The chief disadvantage of the scintillator test was that the uranium plates were too small to fully contain the hadronic showers. However, since the scintillator and liquid argon tests were made with the plates, direct comparison of the two types of devices could be made

  20. Performance of molded plastic scintillators

    International Nuclear Information System (INIS)

    Gen, N.S.; Leman, V.E.; Solomonov, V.M.

    1989-01-01

    The performance of molded plastic scintillators is studied. The plastic scintillators studied were formed by transfer molding and intrusion from a scintillation composition consisting of polystyrene and a standard system of luminescent additives: 2 mass % of paraterphenyl + 0.06 mass % 1,4-di-/2-[5-phenyloxazoyly]/benzene and a plasticizer. The combined effect of mechanical load and temperature was studied. The effect of radiation on molded plastic scintillators was studied using gamma radiation from a 60 Co source. The studies show that the main operating characteristics of molded plastic scintillators are on a par with those of polymerized plastic scintillators. At the same time, molded plastic scintillators are superior in thermal stability at temperatures below the glass transition temperature and with respect to their working temperature range

  1. Multiwire proportional chamber development

    Science.gov (United States)

    Doolittle, R. F.; Pollvogt, U.; Eskovitz, A. J.

    1973-01-01

    The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

  2. The first CEDAR counter

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The first differential Cerenkov counter with chromatic corrections (called CEDAR) successfully tested at the PS in July 75. These counters were used in the SPS hadronic beams for particle identification. Some of the eight photomultipliers can be seen: they receive the light reflected back through the annular diaphragm. René Maleyran stands on the left.

  3. Neutron detection and multiplicity counting using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array

    International Nuclear Information System (INIS)

    Miller, M.C.

    1998-03-01

    Neutron detection and multiplicity counting has been investigated using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array. Boron-loaded plastic combines neutron moderation (H) and detection ( 10 B) at the molecular level, thereby physically coupling increasing detection efficiency and decreasing die-away time with detector volume. Both of these characteristics address a fundamental limitation of thermal-neutron multiplicity counters, where 3 He proportional counters are embedded in a polyethylene matrix. Separation of the phoswich response into its plastic scintillator and bismuth germanate components was accomplished on a pulse-by-pulse basis using custom integrator and timing circuits. In addition, a custom time-tag module was used to provide a time for each detector event. Analysis of the combined energy and time event stream was performed by calibrating each detector's response and filtering based on the presence of a simultaneous energy deposition corresponding to the 10 B(n,alpha) reaction products in the plastic scintillator (93 keV ee ) and the accompanying neutron-capture gamma ray in the bismuth germanate (478 keV). Time-correlation analysis was subsequently performed on the filtered event stream to obtain shift-register-type singles and doubles count rates. Proof-of-principle measurements were conducted with a variety of gamma-ray and neutron sources including 137 Cs, 54 Mn, AmLi, and 252 Cf. Results of this study indicate that a neutron-capture probability of ∼10% and a die-away time of ∼10 micros are possible with a 4-detector array with a detector volume of 1600 cm 3 . Simulations were performed that indicate neutron-capture probabilities on the order of 50% and die-away times of less than 4 micros are realistically achievable. While further study will be required for practical application of such a detection system, the results obtained in this investigation are encouraging and may lead to a new class of high

  4. Spent Nuclear Fuel Cask and Storage Monitoring with {sup 4}He Scintillation Fast Neutron Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hee jun; Kelley, Ryan P; Jordan, Kelly A [Univ. of Florida, Florida (United States); Lee, Wanno [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Chung, Yong Hyun [Yonsei Univ., Wonju (Korea, Republic of)

    2014-10-15

    With this increasing quantity of spent nuclear fuel being stored at nuclear plants across S. Korea, the demand exists for building a long-term disposal facility. However, the Korean government first requires a detailed plan for the monitoring and certification of spent fuel. Several techniques have been developed and applied for the purpose of spent fuel monitoring, including the digital Cerenkov viewing device (DCVD), spent fuel attribute tester (SFAT), and FORK detector. Conventional gamma measurement methods, however, suffer from a lack of nuclear data and interfering background radiation. To date, the primary method of neutron detection for spent fuel monitoring has been through the use of thermal neutron detectors such as {sup 3}He and BF{sub 3} proportional counters. Unfolding the neutron spectrum becomes extremely complicated. In an attempt to overcome these difficulties, a new fast neutron measurement system is currently being developed at the University of Florida. This system is based on the {sup 4}He scintillation detector invented by Arktis Radiation Detectors Ltd. These detectors are a relatively new technological development and take advantage of the high {sup 4}He cross-section for elastic scattering at fast neutron energies, particularly the resonance around 1 MeV. This novel {sup 4}He scintillation neutron detector is characterized by its low electron density, leading to excellent gamma rejection. This detector also has a fast response time on the order of nanoseconds and most importantly, preserves some neutron energy information since no moderator is required. Additionally, these detectors rely on naturally abundant {sup 4}He as the fill gas. This study proposes a new technique using the neutron spectroscopy features of {sup 4}He scintillation detectors to maintain accountability of spent fuel in storage. This research will support spent fuel safeguards and the detection of fissile material, in order to minimize the risk of nuclear proliferation

  5. Recipe for attaining optimal energy resolution in inorganic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Jai; Koblov, Alexander [School of Engineering and IT, B-purple-12, Faculty of EHSE, Charles Darwin University, Darwin, NT 0909 (Australia)

    2012-12-15

    Using an approximate form of the density of excitation created within the track initiated by an incident {gamma} - photon on a scintillator, the light yield is derived as a function of linear, bimolecular and Auger radiative and quenching recombination rates. The non-proportionality in the yield is analysed as a function of the bimolecular and Auger quenching rates and also its dependence on the track radius is studied. An optimal combination of these quenching rates and track radius is presented to obtain a recipe for inventing a scintillator material with optimal energy resolution. The importance of the mobility of charge carriers in minimising the non-proportionality in a scintillator is also discussed (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Recipe for attaining optimal energy resolution in inorganic scintillators

    International Nuclear Information System (INIS)

    Singh, Jai; Koblov, Alexander

    2012-01-01

    Using an approximate form of the density of excitation created within the track initiated by an incident γ - photon on a scintillator, the light yield is derived as a function of linear, bimolecular and Auger radiative and quenching recombination rates. The non-proportionality in the yield is analysed as a function of the bimolecular and Auger quenching rates and also its dependence on the track radius is studied. An optimal combination of these quenching rates and track radius is presented to obtain a recipe for inventing a scintillator material with optimal energy resolution. The importance of the mobility of charge carriers in minimising the non-proportionality in a scintillator is also discussed (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Optical and scintillation properties of bulk ZnO crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Takayuki [Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu, Kitakyushu 808-0196 (Japan); Fujimoto, Yutaka; Kurosawa, Shunsuke [Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Yamanoi, Kohei; Sarukura, Nobuhiko [Institute of Laser Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); Kano, Masataka; Wakamiya, Akira [Daishinku Corporation, 1389 Shinzaike, Hiraoka-cho, Kakogawa, Hyogo 675-0194 (Japan)

    2012-12-15

    Single crystal bulk ZnO scintillator grown by the hydrothermal method was tested on its scintillation performances. In X-ray induced radio luminescence spectrum, it exhibited two intense emission peaks at 400 and 550 nm. The former was ascribed to the free and bound exciton related luminescence and the latter to oxygen vacancy related one, respectively. X-ray induced scintillation decay time of the exciton related emission measured by the pulse X-ray streak camera system resulted {proportional_to} 4 ns. Finally, the light yield under {sup 241}Am 5.5 MeV {alpha}-ray was examined and it resulted {proportional_to} 500 ph/5.5 MeV-{alpha}.(copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Restrictions and Proportionality

    DEFF Research Database (Denmark)

    Werlauff, Erik

    2009-01-01

    The article discusses three central aspects of the freedoms under European Community law, namely 1) the prohibition against restrictions as an important extension of the prohibition against discrimination, 2) a prohibition against exit restrictions which is just as important as the prohibition...... against host country restrictions, but which is often not recognised to the same extent by national law, and 3) the importance of also identifying and recognising an exit restriction, so that it is possible to achieve the required test of appropriateness and proportionality in relation to the rule...

  9. The divine proportion

    CERN Document Server

    Huntley, H E

    1970-01-01

    Using simple mathematical formulas, most as basic as Pythagoras's theorem and requiring only a very limited knowledge of mathematics, Professor Huntley explores the fascinating relationship between geometry and aesthetics. Poetry, patterns like Pascal's triangle, philosophy, psychology, music, and dozens of simple mathematical figures are enlisted to show that the ""divine proportion"" or ""golden ratio"" is a feature of geometry and analysis which awakes answering echoes in the human psyche. When we judge a work of art aesthetically satisfying, according to his formulation, we are making it c

  10. Homestake surface-underground scintillators: Initial results

    International Nuclear Information System (INIS)

    Cherry, M.L.; Corbato, S.; Daily, T.; Fenyves, E.J.; Kieda, D.; Lande, K.; Lee, C.K.

    1986-01-01

    The first 70 tons of the 140-ton Large Area Scintillation Detector (LASD) have been operating since Jan. 1985 at a depth of 4850 ft. (4200 m.w.e.) in the Homestake Gold Mine, Lead, S.D. A total of 4 x 10(4) high-energy muons (E sub mu is approx. 2.7 TeV at the surface) have been detected. The remainder of the detector is scheduled to be in operation by the Fall of 1985. In addition, a surface air shower array is under construction. The first 27 surface counters, spaced out over an area of 270' x 500', began running in June, 1985. The LASD performance, the potential of the combined shower array and underground muon experiment for detecting point sources, and the initial results of a search for periodic emission from Cygnus X-3 are discussed

  11. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  12. Multiwire proportional chamber for Moessbauer spectroscopy: development and results

    International Nuclear Information System (INIS)

    Costa, M.S. da.

    1985-12-01

    A new Multiwere proportional Chamber designed for Moessbauer Spectroscopy is presented. This detector allows transmission backscattering experiments using either photons or electrons. The Moessbauer data acquisition system, partially developed for this work is described. A simple method for determining the frontier between true proportional and semi-proportional regions of operation in gaseous detectors is proposed. The study of the tertiary gas mixture He-Ar-CH 4 leads to a straight forward way of energy calibration of the electron spectra. Moessbauer spectra using Fe-57 source are presented. In particular those obtained with backsattered electrons show the feasibility of depth selective analysis with gaseous proportional counters. (author) [pt

  13. Scintillator detector array

    International Nuclear Information System (INIS)

    Cusano, D.A.; Dibianca, F.A.

    1981-01-01

    This patent application relates to a scintillator detector array for use in computerized tomography and comprises a housing including a plurality of chambers, the said housing having a front wall transmissive to x-rays and side walls opaque to x-rays, such as of tungsten and tantalum, a liquid scintillation medium including a soluble fluor, the solvent for the fluor being disposed in the chambers. The solvent comprises either an intrinsically high Z solvent or a solvent which has dissolved therein a high Z compound e.g. iodo or bromonaphthalene; or toluene, xylene or trimethylbenzene with a lead or tin alkyl dissolved therein. Also disposed about the chambers are a plurality of photoelectric devices. (author)

  14. DETECTORS: scintillating fibres

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    In the continual search for improved detection techniques, new materials are continually proving profitable. A good example is scintillating plastic fibres - tiny transparent threads sometimes finer than a human hair which transmit light. The narrowness and flexibility of these fibres was a major breakthrough for endoscopy - non-invasive techniques for viewing the otherwise inaccessible in surgery or machine inspection. In a more sophisticated form, these fibres find ready application in communications technology, where the goal is to transmit information rather than electrical power, replacing conventional and unwieldy current-carrying wire conductors. In particle physics, fibres have long been used to take the tiny scintillations produced when high energy particles hit fluorescent materials and 'conduct' them to photosensitive detectors some distance away

  15. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  16. Calculation of efficiency of high-energy neutron detection by plastic scintillators

    International Nuclear Information System (INIS)

    Telegin, Yu.N.

    1977-01-01

    A computer was used to calculate neutron (5-30O MeV) registration effeciencies with plastic scintillators 2,5,10, 20,30,40 and 50 cm thick. The results are shown in the form of tables. The contributions to efficiency of various processes have been analysed. The calculation results may be used in planning experiments with neutron counters

  17. Modular scintillation camera

    International Nuclear Information System (INIS)

    Barrett, H. H.

    1985-01-01

    Improved optical coupling modules to be used in coded-aperture-type radiographic imaging systems. In a first system, a rotating slit coded-aperture is employed between the radioactive object and the module. The module consists of one pair of side-by-side photomultipliers receiving light rays from a scintillation crystal exposed to the object via the coded-aperture. The light rays are guided to the photomultipliers by a mask having a central transverse transparent window, or by a cylindrical lens, the mask or lens being mounted in a light-conveying quartz block assembly providing internal reflections at opposite faces of the assembly. This generates output signals from the photomultipliers which can be utilized to compute one-dimensional coordinate values for restoring the image of the radioactive object on a display screen. In another form of optical coupling module, usable with other types of coded-apertures, four square photomultipliers form a substantially square block and receive light rays from scintillations from a scintillation crystal exposed to the radioactive object via the coded-aperture. The light rays are guided to the photomultipliers by a square mask or a centrally transparent square lens configuration mounted in a light-conveying assembly formed by internally reflecting quartz blocks, the optical rays being directed to the respective photomultipliers so as to generate resultant output signals which can be utilized to compute image coordinate values for two-dimensional representation of the radioactive object being examined

  18. Load proportional safety brake

    Science.gov (United States)

    Cacciola, M. J.

    1979-01-01

    This brake is a self-energizing mechanical friction brake and is intended for use in a rotary drive system. It incorporates a torque sensor which cuts power to the power unit on any overload condition. The brake is capable of driving against an opposing load or driving, paying-out, an aiding load in either direction of rotation. The brake also acts as a no-back device when torque is applied to the output shaft. The advantages of using this type of device are: (1) low frictional drag when driving; (2) smooth paying-out of an aiding load with no runaway danger; (3) energy absorption proportional to load; (4) no-back activates within a few degrees of output shaft rotation and resets automatically; and (5) built-in overload protection.

  19. Macroeconomic Proportions and Corellations

    Directory of Open Access Journals (Sweden)

    Constantin Anghelache

    2006-02-01

    Full Text Available The work is focusing on the main proportions and correlations which are being set up between the major macroeconomic indicators. This is the general frame for the analysis of the relations between the Gross Domestic Product growth rate and the unemployment rate; the interaction between the inflation rate and the unemployment rate; the connection between the GDP growth rate and the inflation rate. Within the analysis being performed, a particular attention is paid to �the basic relationship of the economic growth� by emphasizing the possibilities as to a factorial analysis of the macroeconomic development, mainly as far as the Gross Domestic Product is concerned. At this point, the authors are introducing the mathematical relations, which are used for modeling the macroeconomic correlations, hence the strictness of the analysis being performed.

  20. Macroeconomic Proportions and Corellations

    Directory of Open Access Journals (Sweden)

    Constantin Mitrut

    2006-04-01

    Full Text Available The work is focusing on the main proportions and correlations which are being set up between the major macroeconomic indicators. This is the general frame for the analysis of the relations between the Gross Domestic Product growth rate and the unemployment rate; the interaction between the inflation rate and the unemployment rate; the connection between the GDP growth rate and the inflation rate. Within the analysis being performed, a particular attention is paid to “the basic relationship of the economic growth” by emphasizing the possibilities as to a factorial analysis of the macroeconomic development, mainly as far as the Gross Domestic Product is concerned. At this point, the authors are introducing the mathematical relations, which are used for modeling the macroeconomic correlations, hence the strictness of the analysis being performed.

  1. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  2. Counter-cryptanalysis

    NARCIS (Netherlands)

    M.M.J. Stevens (Marc); R. Canetti; J.A. Garay

    2013-01-01

    textabstractWe introduce \\emph{counter-cryptanalysis} as a new paradigm for strengthening weak cryptographic primitives against cryptanalytic attacks. Redesigning a weak primitive to more strongly resist cryptanalytic techniques will unavoidably break backwards compatibility. Instead,

  3. Neutron crosstalk between liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Verbeke, J.M., E-mail: verbeke2@llnl.gov; Prasad, M.K., E-mail: prasad1@llnl.gov; Snyderman, N.J., E-mail: snyderman1@llnl.gov

    2015-09-11

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction.

  4. Neutron crosstalk between liquid scintillators

    International Nuclear Information System (INIS)

    Verbeke, J.M.; Prasad, M.K.; Snyderman, N.J.

    2015-01-01

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction

  5. Gammastic: towards a pseudo-gamma spectrometry in plastic scintillators

    International Nuclear Information System (INIS)

    Hamel, Matthieu; Dehe-Pittance, Chrystele; Coulon, Romain; Carrel, Frederick; Pillot, Philippe; Barat, Eric; Dautremer, Thomas; Montagu, Thierry; Normand, Stephane

    2013-06-01

    War against CBRN-E threats needs to continuously develop sensors with improved detection efficiency. More particularly, this topic concerns the NR controls for homeland security. A first analysis requires indeed a fast gamma spectrometry so as to detect potential special nuclear materials (SNM). To this aim, plastic scintillators could represent the best alternative for the production of large-scale, low-cost radiation portal monitors to be deployed on boarders, tolls, etc. Although they are known to be highly sensitive to gamma rays, due to their poor resolution, information relative to the nature of the SNM is tricky. Thus, only the Compton edge is obtained after interaction, and no information of the photoelectric peak is observed. This project concerns new developments on a possible pseudo-gamma spectrometry performed with plastic scintillators. This project is articulated on a combination of two developments: - The design of new materials most suitable for recovering the photoelectric peak after gamma interaction with the scintillator. This work concerns mainly plastic scintillators loading with heavy elements, such as lead or bismuth. - The analysis of the resulting signal with smart algorithms. This work is thus a pluri-disciplinary work performed at CEA LIST and embeds 4 main disciplines: MCNPX simulations (simulated spectra), chemistry of materials (preparation of various plastic scintillators with different properties), instrumentation (lab experiments) and smart algorithms. Really impressive results were obtained with the unfolding of simulated spectra at various energies (from 241 Am to 60 Co) and an innovative approach was proposed to counter-balance the quenching effect of luminescence by heavy elements in plastic scintillators. (authors)

  6. Photon veto counters at KTeV/KAMI with blue WLS fibers

    International Nuclear Information System (INIS)

    Hanagaki, Kazunori

    1998-01-01

    The photon veto detectors used in KTeV experiment were required to have high detection efficiency with high speed response. To satisfy the requirements, we used scintillation counters with blue wave length shifter fibers for their readout. This document describes the design and performance of the photon veto detectors and a possible improvement for future experiments

  7. Use of proportional counter in X-Ray spectrometry between 5 and 100 keV. Application to the detection of fission products and to the determination of absolute X-Ray disintegration rates; Utilisation d'un compteur proportionnel en spectrometrie de rayons X entre 5 et 100 keV. Application a la detection des produits de fission et a la determination des taux d'emission X absolus

    Energy Technology Data Exchange (ETDEWEB)

    Cerf, J [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1969-07-01

    The measurement of electromagnetic radiations is difficult in the energy range 20-100 keV. We made suitable for this purpose a regular proportional counter, modifying both the nature and pressure of the gaseous mixture filling the detector volume. We selected the CPEN-SAIP counter, which is able to withstand such modifications. In the energy range considered, the counter is to be standardized with radioactive sources. Such standards were selected according to their disintegration schemes. We thus defined the conditions of use (resolution, yield) of the CPN counter, filled with an argon-methane mixture under a pressure of about 3 bars, in the energy range 5-100 keV. With such an equipment, we were able to measure the absolute disintegration rate for the X-rays of 133 Ba and 75 Se, then to perform the study of a mixed fission products sample. In the same way, we used xenon-based gaseous mixtures, in order to improve the detector yield; in the later case, we carefully examined the limitations introduced by the presence of many parasite rays emitted by the gas. We thus displayed in addition to the leakage peak, the fluorescence ray of the gas, whose origin is difficult to explain. (author) [French] La mesure des rayonnements electromagnetiques est difficile dans une bande d'energie comprise entre 20 et 100 keV environ. Nous avons rendu utilisable, a cet effet, un compteur proportionnel existant en modifiant la nature et la pression du melange gazeux constituant le volume detecteur. De par sa construction, le compteur CPXN, fabrique par les Etablissements S.A.I.P., rend ces experiences possibles. C'est pourquoi nous l'avons choisi. Dans le domaine d'energie consideree l'etalonnage du compteur necessite l'emploi de sources radioactives. Pour les preparer, nous sommes amenes a choisir les radio-nucleides utilisables par l'etude de leur schema de desintegration. Ainsi, nous avons defini les conditions d'utilisation (resolution, efficacite) du compteur CPNX rempli d

  8. Response function of the trigger scintillation detector for the COSY 11 installation

    International Nuclear Information System (INIS)

    Moskal, P.

    1993-10-01

    The aim of this work is to test the response of a scintillation detector to ionizing particles. This counter, consisting of sixteen detection modules, will serve as a trigger of the whole detection system. Thus the time resolution as well as a signal amplitude variation with respect to a hit position is of a special interest. The former because this detector will be used as a start counter for the time of flight measurement, the latter as it will provide energy loss measurements of the particles. The present work is divided into two parts. In the first one the main stages of a signal production by scintillation counters are considered. In the second one the first chapter presents measurements of the characteristics of the photomultiplier, whereas the second one contains a description of the experimental set-ups as well as the method of data evaluation. The final chapter in turn presents the main characteristics of the considered detector. (orig.)

  9. ATLAS ALFA—measuring absolute luminosity with scintillating fibres

    CERN Document Server

    Franz, S

    2009-01-01

    ALFA is a high-precision scintillating fibre tracking detector under construction for the absolute determination of the LHC luminosity at the ATLAS interaction point. This detector, mounted in so-called Roman Pots, will track protons elastically scattered under μrad angles at IP1.In total there are four pairs of vertically arranged detector modules which approach the LHC beam axis to mm distance. Each detector module consists of ten layers of two times 64 scintillating fibres each (U and V planes). The fibres are coupled to 64 channels Multi-Anodes PhotoMultipliers Tubes read out by compact front-end electronics. Each detector module is complemented by so-called overlap detectors: Three layers of two times 30 scintillating fibres which will be used to measure the relative positioning of two vertically arranged main detectors. The total number of channels is about 15000. Conventional plastic scintillator tiles are mounted in front of the fibre detectors and will serve as trigger counter. The extremely restric...

  10. Multisector scintillation detector with fiber-optic light collection

    Science.gov (United States)

    Ampilogov, N. V.; Denisov, S. P.; Kokoulin, R. P.; Petrukhin, A. A.; Prokopenko, N. N.; Shulzhenko, I. A.; Unatlokov, I. B.; Yashin, I. I.

    2017-07-01

    A new type of scintillation detector for the use in high energy physics is described. The octagonal detector consists of eight triangular scintillator sectors with total area of 1 m2. Each sector represents two plates of 2 cm thick plastic scintillator. Seven 1 mm thick WLS fibers are laid evenly between the plates. The space between the fibers is filled with silicone compound to provide better light collection. Fiber ends from all eight sectors are gathered in the central part of the detector into a bunch and docked to the cathode of a FEU-115m photomultiplier. The read-out of the counter signals is carried out from 7th and 12th dynodes, providing a wide dynamic range up to about 10000 particles. The front-end electronics of the detector is based on the flash-ADC with a sampling frequency of 200 MHz. The features of detecting and recording systems of the multisector scintillation detector (MSD) and the results of its testing are discussed.

  11. Scintillating-fibre calorimetry

    International Nuclear Information System (INIS)

    Livan, M.; Vercesi, V.; Wigmans, R.

    1995-01-01

    In the past decade, calorimetry based on scintillating plastic fibres as active elements was developed from a conceptual idea to a mature detector technology, which is nowadays widely applied in particle physics experiments. This development and the performance characteristics of representative calorimeters, both for the detection of electromagnetic and hadronic showers, are reviewed. We also discuss new information on shower development processes in dense matter and its application to calorimetric principles that has emerged from some very thorough studies that were performed in the framework of this development. (orig.)

  12. Study of semileptonic and leptonic neutral-current processes and of $\\mu$-polarization using counter techniques

    CERN Document Server

    2002-01-01

    .PP This experiment will study semileptonic neutral current neutrino interactions with nucleons, using principally the dichromatic neutrino beam N1 and will make measurements of the polarization of muons produced in the WA1 experiment by neutrino-nucleon interactions, using the horn-focused broad-band neutrino The main part of the apparatus is a fine-grained target calorimeter in which the energy and direction of the hadronic jet resulting from the neutrino scattering is measured by electronic techniques. It is supplemented by a muon detector and spectrometer. The fine-grained calorimeter is used as a polarimeter for muons produced in WA1. \\\\ \\\\ The calorimeter is composed of 13 modules, each 1.2 m long and 4~m x 4~m in cross section. A module consists of six 3 m x 3 m target plates made of 8 cm thick marble with 12 cm gaps for insertion of 20 scintillation counters of 15 cm width and 3 cm thickness, 128 proportional counters of 3~x~3~cm|2 cross-section and 4~m length, and 256 streamer tubes of 0.9~x~0.9~cm|2...

  13. Primary 4{pi}{beta}-{gamma} coincidence system for standardization of radionuclides by means of plastic scintillators; Sistema primario por coincidencias 4{pi}{beta}-{gamma} para a padronizacao de radionuclideos empregando cintiladores plasticos

    Energy Technology Data Exchange (ETDEWEB)

    Baccarelli, Aida Maria

    2003-07-01

    The present work describes a 4{pi}({alpha},{beta})-{gamma} coincidence system for absolute measurement of radionuclide activity using a plastic scintillator in 4{pi} geometry for charged particles detection and a Nal (Tl) crystal for gamma-ray detection. Several shapes and dimensions of the plastic scintillator have been tried in order to obtain the best system configuration. Radionuclides which decay by alpha emission, {beta}{sup -}, {beta}{sup +} and electron capture have been standardized. The results showed excellent agreement with other conventional primary system which makes use of a 4{pi} proportional counter for X-ray and charged particle detection. The system developed in the present work have some advantages when compared with the conventional systems, namely; it does not need metal coating on the films used as radioactive source holders. When compared to liquid scintillators, is showed the advantage of not needing to be kept in dark for more than 24 h to allow phosphorescence decay of ambient light. Therefore it can be set to count immediately after the sources are placed inside of it. (author)

  14. Hybrid scintillators for neutron discrimination

    Science.gov (United States)

    Feng, Patrick L; Cordaro, Joseph G; Anstey, Mitchell R; Morales, Alfredo M

    2015-05-12

    A composition capable of producing a unique scintillation response to neutrons and gamma rays, comprising (i) at least one surfactant; (ii) a polar hydrogen-bonding solvent; and (iii) at least one luminophore. A method including combining at least one surfactant, a polar hydrogen-bonding solvent and at least one luminophore in a scintillation cell under vacuum or an inert atmosphere.

  15. Liquid scintillation in medical diagnosis

    International Nuclear Information System (INIS)

    Painter, K.

    1976-01-01

    With the tremendous increase in the application of radioassay, particularly radioimmunoassay, in the clinical laboratory liquid scintillation counting became an indispensable tool in diagnostic medicine. Few publications, however, have concerned themselves with problem areas which occur with the method in the clinical laboratory. The purpose of this presentation is to summarize our experiences with the liquid scintillation technique in the clinical situation

  16. A user's guide to scintillation

    International Nuclear Information System (INIS)

    Hewish, A.

    1989-01-01

    During the past four decades scintillation methods have been used for remote-sensing distant plasmas and for providing high angular resolution in radioastronomy. This brief review illustrates some of the techniques employed and explains the underlying theory in simple physical terms; it is not intended to be a complete survey of all applications of scintillation. (author)

  17. Laser Beam Scintillation with Applications

    CERN Document Server

    Andrews, Larry C; Young, Cynthia

    2001-01-01

    Renewed interest in laser communication systems has sparked development of useful new analytic models. This book discusses optical scintillation and its impact on system performance in free-space optical communication and laser radar applications, with a detailed look at propagation phenomena and the role of scintillation on system behavior. Intended for practicing engineers, scientists, and students.

  18. Scintillation light transport and detection

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Lillie, R.A.

    1986-08-01

    The MORSE neutron gamma-ray transport code has been modified to allow for the transport of scintillation light. This modified code is used to analyze the light collection characteristics of a large liquid scintillator module (18 x 18 x 350 cm 3 )

  19. Extruding plastic scintillator at Fermilab

    International Nuclear Information System (INIS)

    Pla-Dalmau, Anna; Bross, Alain D.; Rykalin, Viktor V.

    2003-01-01

    An understanding of the costs involved in the production of plastic scintillators and the development of a less expensive material have become necessary with the prospects of building very large plastic scintillation detectors. Several factors contribute to the high cost of plastic scintillating sheets, but the principal reason is the labor-intensive nature of the manufacturing process. In order to significantly lower the costs, the current casting procedures had to be abandoned. Since polystyrene is widely used in the consumer industry, the logical path was to investigate the extrusion of commercial-grade polystyrene pellets with dopants to yield high quality plastic scintillator. This concept was tested and high quality extruded plastic scintillator was produced. The D0 and MINOS experiments are already using extruded scintillator strips in their detectors. An extrusion line has recently been installed at Fermilab in collaboration with NICADD (Northern Illinois Center for Accelerator and Detector Development). This new facility will serve to further develop and improve extruded plastic scintillator. This paper will discuss the characteristics of extruded plastic scintillator and its raw materials, the different manufacturing techniques and the current R andD program at Fermilab

  20. Selective solvent extraction of actinides associated to liquid scintillation measurements

    International Nuclear Information System (INIS)

    Ardois, C.; Musikas, C.

    1997-01-01

    The problems associated to radioactive waste disposal have acquired a special attention due, particularly, to the element instability and, consequently, to their lixiviation and to their peculiarities which are essential in the radioactivity penetration in the food chains; the other important parameters are the produced amounts and the noxiousnesses. New commercial liquid scintillation counters allow rapid α/β measurements. Associated with liquid-liquid extraction techniques, rapid and selective actinide analyses are possible. Among various actinide extractants, such as amines or organophosphorus compounds, we were particularly interested in tri-n-octyl-phosphine oxide (TOPO). Uranium, thorium and americium extractions with (TOPO) in toluene have been investigated. A systematic study of the counting parameters of a PACKARD 2550 TR/AB TM liquid scintillation analyzer is under completion