  1. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  2. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  3. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  4. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  5. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  6. A comparative study using liquid scintillation counting to determine 63Ni in low and intermediate level radioactive waste

    International Nuclear Information System (INIS)

    Gautier, Celine; Colin, Christele; Garcia, Cecile

    2016-01-01

    A comparative study using liquid scintillation counting was performed to measure 63 Ni in low and intermediate level radioactive waste. Three dimethylglyoxime (DMG)-based radiochemical procedures (solvent extraction, precipitation, extraction chromatography) were investigated, the solvent extraction method being considered as the reference method. Theoretical speciation calculations enabled to better understand the chemical reactions involved in the three protocols and to optimize them. In comparison to the method based on DMG precipitation, the method based on extraction chromatography allowed to achieve the best results in one single step in term of recovery yield and accuracy for various samples. (author)

  7. Preparation of 45Ca(HDEHP)n and (CaH1502)2 samples for liquid scintillation counting, compared to 45caCl2 results

    International Nuclear Information System (INIS)

    Rodriguez, L.; Arcos, J. M. los; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethylhexanoate calcium salt, labelled with 45Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators,Toluene-alcohol, Dioxane-naphtalene, Hi safe II, Ultimate-Gold and Instagel, and compared to results obtained from a commercial solution of 4 5CaCl2. (Author) 7 refs

  8. Optics study of liquid scintillation counting systems

    International Nuclear Information System (INIS)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-01-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  9. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  10. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  11. Upgradation of automatic liquid scintillation counting system

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Behere, Anita; Sonalkar, S.Y.; Vaidya, P.P.

    2001-01-01

    This paper describes the upgradation of Microprocessor based Automatic Liquid Scintillation Counting systems (MLSC). This system was developed in 1980's and subsequently many systems were manufactured and supplied to Environment Survey labs at various Nuclear Power Plants. Recently this system has been upgraded to a more sophisticated one by using PC add-on hardware and developing Windows based software. The software implements more intuitive graphical user interface and also enhances the features making it comparable with commercially available systems. It implements data processing using full spectrum analysis as against channel ratio method adopted earlier, improving the accuracy of the results. Also it facilitates qualitative as well as quantitative analysis of the β-spectrum. It is possible to analyze a sample containing an unknown β-source. (author)

  12. Scintillation counting: an extrapolation into the future

    International Nuclear Information System (INIS)

    Ross, H.H.

    1983-01-01

    Progress in scintillation counting is intimately related to advances in a variety of other disciplines such as photochemistry, photophysics, and instrumentation. And while there is steady progress in the understanding of luminescent phenomena, there is a virtual explosion in the application of semiconductor technology to detectors, counting systems, and data processing. The exponential growth of this technology has had, and will continue to have, a profound effect on the art of scintillation spectroscopy. This paper will review key events in technology that have had an impact on the development of scintillation science (solid and liquid) and will attempt to extrapolate future directions based on existing and projected capability in associated fields. Along the way there have been occasional pitfalls and several false starts; these too will be discussed as a reminder that if you want the future to be different than the past, study the past

  13. Liquid scintillation counting (LSC) - an overview

    International Nuclear Information System (INIS)

    Ravi, S.; Mathew, K.M.

    2005-01-01

    In Liquid Scintillation Counting, the amount of light produced is proportional to the amount of radiation present in the sample and the energy of the light produced is proportional to the energy of the radiation that is present in the sample. This makes LSC a very convenient tool to measure radioactivity

  14. Liquid scintillation counting system with automatic gain correction

    International Nuclear Information System (INIS)

    Frank, R.B.

    1976-01-01

    An automatic liquid scintillation counting apparatus is described including a scintillating medium in the elevator ram of the sample changing apparatus. An appropriate source of radiation, which may be the external source for standardizing samples, produces reference scintillations in the scintillating medium which may be used for correction of the gain of the counting system

  15. Applications of low level liquid scintillation counting

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1983-01-01

    Low level liquid scintillation counting is reviewed in terms of its present use and capabilities for measuring low activity samples. New areas of application of the method are discussed with special interest directed to the food industry and environmental monitoring. Advantages offered in the use of a low background liquid scintillation counter for the nuclear power industry and nuclear navy are discussed. Attention is drawn to the need for commercial development of such instrumentation to enable wider use of the method. A user clientele is suggested as is the required technology to create such a counter

  16. Preparation of 45 Ca (HDEHP)n and (C8H15O2)2 samples for liquid scintillation counting, compared to 45CaCl2 results

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos Merino, J.M.; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethyhexanoate calcium salt, labelled with ''45 Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-napthalhene, Hisafe II, Ultima-Gold and Instagel, and compared to results obtained from a commercial solution of ''45 CaCl 2

  17. PMP, a novel solute for liquid and plastic scintillation counting

    International Nuclear Information System (INIS)

    Gusten, Hans

    1983-01-01

    The excellent fluorescence properties of PMP ( 11-phenyl-3-mesityl-2-pyrazoline) such as long wavelength emission of over 400 nm, and high fluorescence quantum yield with a short decay time together with a solubility of more than one Mol/L in toluene make this compound a promising solute for scintillation counting. The Stokes' shift of PMP of over 10,000 cm -1 is twice as large as that of the commonly used PPO. Due to this unusually large Stokes' shift PMP can be used as a primary solute without requiring a secondary solute as wavelength shifter. A comparison of the scintillation properties of PMP and PPO in toluene reveals that the counting efficiency for 14 C is better for PMP while the 3 H efficiency is equally good. Due to the large Stokes' shift, PMP is about 50 percent less sensitive to color quenching than PPO. Compared to the solute combinations PPO/secondary solutes, the scintillation counting efficiency of PMP for 14 C in toluene or xylene is the same, while the absolute 3 H efficiency of PPO/secondary solutes in cocktails with emulsifiers is about 10 percent higher. The PMP scintillation efficiency for 14 C as well as 3 H in chemical quenching by urine is more or less the same as for PPO/dimethyl-POPOP. PMP is more sensitive to quenching by halogenated solvents. In the dioxane-based scintillation, this sensitivity to chemical quenching by CHCl 3 vanishes and the counting efficiencies for 14 C and 3 H are as good as for PPO/dimethyl-POPOP or PPO/bis-MSB. Due to the large Stokes' shift, the self-absorption of the scintillation light by PMP is lower than in conventional scintillators. This offers good possibilities in very large-volume applications of liquid as well as plastic scintillators

  18. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  19. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    1974-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers which give homogeneous monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous monophasic-appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  20. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kauffman, J.M.

    1976-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers, which give homogeneous, monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques, which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous, monophasic appearing aqueous couting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  1. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kauffman, J.M.

    1978-01-01

    Liquid scintillation compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers, which give homogeneous, monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques, which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous, monophasic appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  2. Liquid scintillation counting analysis of cadmium-109

    International Nuclear Information System (INIS)

    Robinson, M.K.; Barfuss, D.W.

    1991-01-01

    Recently the authors have used radiolabled cadmium-109 to measure the transport of inorganic cadmium in renal proximal tubules. An anomaly discovered in the liquid scintillation counting analysis of Cd-109 which is not attributable to normal decay; it consists of a significant decrease in the measured count rate of small amounts of sample. The objective is to determine whether the buffer solution used in the membrane transport studies is causing precipitation of the cadmium or whether cadmium is being adsorbed by the glass. It was important to determine whether the procedure could be modified to correct this problem. The problem does not appear to be related to the use of the buffer or to adsorption of Cd onto glass. Correction based on using triated L-glucose in all of these experiments and calculating a correction factor for the concentration of cadmium

  3. Data process of liquid scintillation counting

    International Nuclear Information System (INIS)

    Ishikawa, Hiroaki; Kuwajima, Susumu.

    1975-01-01

    The use of liquid scintillation counting system has been significantly spread because automatic sample changers and printers have recently come to be incorporated. However, the system will be systematized completely if automatic data processing and the sample preparation of radioactive materials to be measured are realized. Dry or wet oxidation method is applied to the sample preparation when radioactive materials are hard to dissolve into scintillator solution. Since these several years, the automatic sample combustion system, in which the dry oxidation is automated, has been rapidly spread and serves greatly to labor saving. Since the printers generally indicate only counted number, data processing system has been developed, and speeded up calculating process, which automatically corrects quenching of samples for obtaining the final radioactivity required. The data processing system is roughly divided into on-line and off-line systems according to whether computers are connected directly or indirectly, while its hardware is classified to input, calculating and output devices. Also, the calculation to determine sample activity by external standard method is explained. (Wakatsuki, Y.)

  4. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  5. Use of pliable bags in liquid scintillation counting

    International Nuclear Information System (INIS)

    Simonnet, G.; Jacquet, M.A.; Sharif, A.; Engler, R.

    1981-01-01

    Pliable plastic bags have been used to replace glass or plastic vials for liquid scintillation counting. The two major advantages of this method are the lower cost of the plastic bags and the fact that, per sample, the radioactive waste is significantly reduced. The following parameters have been checked: the impermeability of the bags to various scintillator mixtures and the fact that neither the irregular shape of the bags nor their position in the counting chamber had any effect on the results of the counting. The latter was also constant with time, at least over a period of 10 days. The technique has been used to count the radioactivity of 3 H-DNA precipitates prepared from bacteria and lymphocytes and deposited on filters impregnated with only 200 μl scintillator. It is a method that can be applied to the counting of any samples deposited on filters and insoluble in scintillator. (author)

  6. A new method of quench monitoring in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1978-01-01

    The quench level of different liquid scintillation counting samples is measured by comparing the responses (pulse heights) produced by the same energy electrons in each sample. The electrons utilized in the measurements are those of the maximum energy (Esub(max)) which are produced by the single Compton scattering process for the same energy gamma-rays in each sample. The Esub(max) response produced in any sample is related to the Esub(max) response produced in an unquenched, sealed standard. The difference in response on a logarithm response scale is defined as the ''H Number''. The H number is related to the counting efficiency of the desired radionuclide by measurement of a set of standards of known amounts of the radionuclide and different amounts of quench (standard quench curve). The concept of the H number has been shown to be theoretically valid. Based upon this proof, the features of the H number concept as embodied in the Beckman LS-8000 Series Liquid Scintillation Systems have been demonstrated. It has been shown that one H number is unique; it provides a method of instrument calibration and wide dynamic quench range measurements. Further, it has been demonstrated that the H number concept provides a universal quench parameter. Counting efficiency vs. H number plots are repeatable within the statistical limits of +-1% counting efficiency. By the use of the H number concept a very accurate method of automatic quench compensation (A.Q.C.) is possible. (T.G.)

  7. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  8. Set of counts by scintillations for atmospheric samplings; Ensemble de comptages par scintillations pour prelevements atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Appriou, D.; Doury, A.

    1962-07-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies.

  9. 2003: A centennial of spinthariscope and scintillation counting

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Hollander, W. den

    2004-01-01

    In 1903 W. Crookes demonstrated in England his 'spinthariscope' for the visual observation of individual scintillations caused by alpha particles impinging upon a ZnS screen. In contrast to the analogue methods of radiation measurements in that time the spinthariscope was a single-particle counter, being the precursor of scintillation counters since. In the same period F. Giesel, J. Elster and H. Geitel in Germany also found that scintillations from ZnS represent single particle events. This paper summarises the historical events relevant to the advent of scintillation counting

  10. Problems and precision of the alpha scintillation radon counting system

    International Nuclear Information System (INIS)

    Lucas, H.F.; Markuu, F.

    1985-01-01

    Variations in efficiency as large as 3% have been found for radon scintillation counting systems in which the photomultiplier tubes are sensitive to the thermoluminescent photons emitted by the scintillator after exposure to light or for which the resolution has deteriorated. The additional standard deviation caused by counting a radon chamber on multiple counting systems has been evaluated and the effect, if present, did not exceed about 0.1%. The chambers have been calibrated for the measurement of radon in air, and the standard deviation was equal to statistical counting error combined with a systematic error of 1.1%. 3 references, 2 figures, 2 tables

  11. A scintillation detector signal processing technique with active pileup prevention for extending scintillation count rates

    International Nuclear Information System (INIS)

    Wong, W.H.; Li, H.

    1998-01-01

    A new method for processing signals from scintillation detectors is proposed for very high count-rate situations where multiple-event pileups are the norm. This method is designed to sort out and recover every impinging event from multiple-event pileups while maximizing the collection of scintillation signal for every event to achieve optimal accuracy in determining the energy of the event. For every detected event, this method cancels the remnant signals from previous events, and excludes the pileup of signals from following events. With this technique, pileup events can be recovered and the energy of every recovered event can be optimally measured despite multiple pileups. A prototype circuit demonstrated that the maximum count rates have been increased by more than 10 times, comparing to the standard pulse-shaping method, while the energy resolution is as good as that of the pulse shaping (or the fixed integration) method at normal count rates. At 2 x 10 6 events/sec for NaI(Tl), the true counts acquired are 3 times more than the delay-line clipping method (commonly used in fast processing designs) due to events recovered from pileups. Pulse-height spectra up to 3.5 x 10 6 events/sec have been studied

  12. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  13. Detectors for proton counting. Si-APD and scintillation detectors

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2008-01-01

    Increased intensity of synchrotron radiation requests users to prepare photon pulse detectors having higher counting rates. As detectors for photon counting, silicon-avalanche photodiode (Si-APD) and scintillation detectors were chosen for the fifth series of detectors. Principle of photon detection by pulse and need of amplification function of the detector were described. Structure and working principle, high counting rate measurement system, bunch of electrons vs. counting rate, application example of NMR time spectroscopy measurement and comments for users were described for the Si-APD detector. Structure of scintillator and photomultiplier tube, characteristics of scintillator and performance of detector were shown for the NaI detector. Future development of photon pulse detectors was discussed. (T. Tanaka)

  14. Direct photon-counting scintillation detector readout using an SSPM

    International Nuclear Information System (INIS)

    Stapels, Christopher J.; Squillante, Michael R.; Lawrence, William G.; Augustine, Frank L.; Christian, James F.

    2007-01-01

    Gamma-ray detector technologies, capable of providing adequate energy information, use photomultiplier tubes (PMTs) or silicon avalanche photodiodes to detect the light pulse from a scintillation crystal. A new approach to detect the light from scintillation materials is to use an array of small photon counting detectors, or a 'detector-on-a-chip' based on a novel 'Solid-state Photomultiplier' (SSPM) concept. A CMOS SSPM coupled to a scintillation crystal uses an array of CMOS Geiger photodiode (GPD) pixels to collect light and produce a signal proportional to the energy of the radiation. Each pixel acts as a binary photon detector, but the summed output is an analog representation of the total photon intensity. We have successfully fabricated arrays of GPD pixels in a CMOS environment, which makes possible the production of miniaturized arrays integrated with the detector electronics in a small silicon chip. This detector technology allows for a substantial cost reduction while preserving the energy resolution needed for radiological measurements. In this work, we compare designs for the SSPM detector. One pixel design achieves maximum detection efficiency (DE) for 632-nm photons approaching 30% with a room temperature dark count rate (DCR) of less than 1 kHz for a 30-μm-diameter pixel. We characterize after pulsing and optical cross talk and discuss their effects on the performance of the SSPM. For 30-μm diameter, passively quenched CMOS GPD pixels, modeling suggests that a pixel spacing of approximately 90 μm optimizes the SSPM performance with respect to DE and cross talk

  15. Sample oxidation for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kisieleski, W.E.; Buess, E.M.

    1976-01-01

    The general features of biological and medical investigations which are responsible for the demands such investigations place upon the design specifications of liquid scintillation counters and associated methodology are reviewed. Special emphasis is given to the oxidative technique for sample preparation

  16. Low level scintillation counting of 239Pu

    International Nuclear Information System (INIS)

    Fueloep, M.; Minarik, F.; Cierna, V.

    1984-01-01

    For measuring the content of 239 Pu in samples taken from the working or living environment, methods should be used which are sufficiently sensitive for determining activities of the order of 10 -3 Bq. It is useful to use liquid scintillators for reasons of their 4π geometry and the exclusion of kinetic energy losses of particles detected in the sample and on the path between the sample and the detector. The method of background discrimination according to pulse shape may be used to suppress gamma background in the area of alpha particle peaks to the level 2.5x10 -4 s -1 . The diagram is given of electronic circuits for shape discrimination. The scintillator used was a SLS-31 with a PBD activator, a POPOP spectrum shifter and a mixture of solvents: toluene, dioxane and methanol. The efficiency of 239 Pu alpha particle detection is estimated at 78% and may further be improved by improving shape discrimination. (M.D.)

  17. Evaluation of oxidation techniques for preparing bioassay and environmental samples for liquid scintillation counting

    International Nuclear Information System (INIS)

    Miller, H.H.

    1979-10-01

    In environmental and biological monitoring for carbon-14 and tritium, the presence of color and chemical quenching agents in the samples can degrade the efficiency of liquid scintillation counting. A series of experiments was performed to evaluate the usefulness, under routine conditions, of first oxidizing the samples to improve the counting by removing the color and quenching agents. The scintillation counter was calibrated for the effects of quenching agents on its counting efficiency. Oxidizing apparatus was tested for its ability to accurately recover the 14 C and 3 H in the samples. Scintillation counting efficiences were compared for a variety of oxidized and unoxidized environmental and bioassay samples. The overall conclusion was that, for routine counting, oxidation of such samples is advantageous when they are highly quenched or in solid form

  18. Characteristics of commercially available well scintillation counting systems

    International Nuclear Information System (INIS)

    Morris, A.C. Jr.; Dudley, R.A.

    1977-01-01

    The document contains data on commercially available well scintillation counting systems as collected during early 1977, and up-dated in July 1977, by the staff of the Medical Application Section, Division of Life Sciences, IAEA. These data also appear as Appendix 2 of IAEA-201, Well Scintillation Counting Systems for Nuclear Medicine Applications in Developing Countries, Vienna, 1977. An attempt was made to include instruments currently offered by all manufacturers. However, it is inevitable that several manufacturers remain unknown to the Section, and a number of known manufacturers failed to provide adequate information. (orig.) [de

  19. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  20. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  1. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  2. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  3. Chemical and colour quenching in liquid scintillation counting

    International Nuclear Information System (INIS)

    Scott G, P. E.; Grau M, A.

    1987-01-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs

  4. Correct liquid scintillation counting of steroids and glycosides in RIA samples: a comparison of xylene-based, dioxane-based and colloidal counting systems. Chapter 14

    International Nuclear Information System (INIS)

    Spolders, H.

    1977-01-01

    In RIA, the following parameters are important for accurate liquid scintillation counting. (1) Absence of chemiluminescence. (2) Stability of count rate. (3) Dissolving properties for the sample. For samples with varying colours, a quench correction must be applied. For any type of accurate quench correction, a homogeneous sample is necessary. This can be obtained if proteins and the buffer can be dissolved completely in the scintillator solution. In this paper, these criteria are compared in xylene-based, dioxane-based and colloidal scintillation solutions for either bound or free antigens of different polarity. The labelling radioisotope used was 3 H. Using colloidal scintillators with plasma and buffer samples, phasing or sedimentation of salt or proteins sometimes occurs. The influence of sedimentation or phasing on count rate stability and correct quench correction is illustrated by varying the ratio between the scintillator solution and a RIA sample containing a semi-polar steroid aldosterone. (author)

  5. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  6. Alpha liquid scintillation counting: past, present, and future

    International Nuclear Information System (INIS)

    McDowell, W.J.

    1979-01-01

    Beta liquid scintillation counting has been used for about 30 years, and its effectiveness for alpha particles has been known for almost that long; however, the technique has not been widely applied to alpha particle detection because of poor energy resolution, high background, and variable interference from beta and gamma radiation. Beginning with the work of Horrocks in the early 1960s, improvements in energy resolution and background rejection have been made. Further developments at Oak Ridge National Laboratory over the past 10 to 12 years have resulted in improved methods of sample preparation (using liquid-liquid extraction methods to isolate the sample and introduce it into the scintillator) and better instrumentation, including electronic rejection of beta and gamma pulses. Energy resolutions of 200- to 300-keV FWHM and background counts of 0.01 cpm are now routine. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are outlined for a variety of analyses

  7. Assay of /sup 32/Si by liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Cumming, J B [Brookhaven National Lab., Upton, NY (USA)

    1983-10-03

    Application of the radioactivity of /sup 32/Si to problems of interest in geo- and cosmo-chemistry has been hampered by uncertainties in the half-life of this nuclide. A procedure for the stimulation assay of /sup 32/Si and its /sup 32/P daughter utilizing a liquid scintillation detector in association with a pulse height analyzer is described. The results indicate that /sup 32/Si can be assayed to an accuracy of a few percent by liquid scintillation counting techniques which do not require the preparation of an organic Si derivative. Combination of the mean specific activity with the /sup 32/Si abundance determined by accelerator-based mass spectrometry gave the reported 101+-18 year half-life.

  8. Tritium activity in milk by liquid scintillation counting

    International Nuclear Information System (INIS)

    Zheng Huang

    1993-01-01

    This paper estimates the total tritium content of both the organic and aqueous fractions simultaneously. To fulfill these conditions, the chosen scintillator should be able to accept large sample loadings and display the same counting efficiency for the organic as well as aqueous fractions of the whole milk. In an attempt to establish this method, samples from four different brands of milk were analysed using the pseudocumence based Picofluor 30 (Canberra Packard) and the di-isopropyl naphthalene based Aquasafe 500 (Zinser Analytic) scintillator solution. Glass vials were used thus enabling visual observation to be made. The tritium activities of four different brands of milks were estimated to be very low and at, or near, the detection level of the system

  9. Chemical and colour quenching in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Scott Guilleard, P.E.

    1986-01-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red (4'-dimethylamine-azobenzene 2-carboxilic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and melachite green (metane, bis (4'-dimethyl aminophenyl)-(phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (author). 10 figs., 12 refs

  10. Scinfi, a program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1984-01-01

    A code, Scinfi, was developed, written in Basic, to compute the efficiency-quench standardization curve for any radionuclide. The program requires the standardization curve for 3 H and the polynomial relations between counting efficiency and figure of merit for both 3 H and the problem (e.g. 14 C). The program is applied to the computation of the efficiency-quench standardization curve for 14 C. Five different liquid scintillation spectrometers and two scintillator solutions have been checked. The computation results are compared with the experimental values obtained with a set of 14 C standardized samples. (author)

  11. SCINFI, a program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1984-01-01

    A code, SCINFI, was developed, written in BASIC, to compute the efficiency- quench standardization curve for any radionuclide. The program requires the standardization curve for 3H and the polynomial relations between counting efficiency and figure of merit for both 3H and the problem (e.g. 14 C ). The program is applied to the computation of the efficiency-quench standardization curve for 14 c . Five different liquid scintillation spectrometers and two scintillator solutions have bean checked. The computation results are compared with the experimental values obtained with a set of 14 c standardized samples. (Author)

  12. Simple analytical technique for liquid scintillation counting of environmental carbon-14 using gel suspension method

    International Nuclear Information System (INIS)

    Okai, Tomio; Wakabayashi, Genichiro; Nagao, Kenjiro; Matoba, Masaru; Ohura, Hirotaka; Momoshima, Noriyuki; Kawamura, Hidehisa

    2000-01-01

    A simple analytical technique for liquid scintillation counting of environmental 14 C was developed. Commercially available gelling agent, N-lauroyl-L -glutamic -α,γ-dibutylamide, was used for the gel-formation of the samples (gel suspension method) and for the subsequent liquid scintillation counting of 14 C in the form of CaCO 3 . Our procedure for sample preparation is much simpler than that of the conventional methods and requires no special equipment. Self absorption, stability and reproducibility of gel suspension samples were investigated in order to evaluate the characteristics of the gel suspension method for 14 C activity measurement. The self absorption factor is about 70% and slightly decrease as CaCO 3 weight increase. This is considered to be mainly due to the absorption of β-rays and scintillation light by the CaCO 3 sample itself. No change of the counting rate for the gel suspension sample was observed for more than 2 years after the sample preparation. Four samples were used for checking the reproducibility of the sample preparation method. The same values were obtained for the counting rate of 24 C activity within the counting error. No change of the counting rate was observed for the 're-gelated' sample. These results show that the gel suspension method is appropriate for the 14 C activity measurement by the liquid scintillation counting method and useful for a long-term preservation of the sample for repeated measurement. The above analytical technique was applied to actual environmental samples in Fukuoka prefecture, Japan. Results obtained were comparable with those by other researchers and appear to be reasonable. Therefore, the newly developed technique is useful for the routine monitoring of environmental 14 C. (author)

  13. The ionization quench factor in liquid-scintillation counting standardizations

    CERN Document Server

    Grau-Malonda, A

    1999-01-01

    We present a new detailed analysis of the ionization quench function Q(E) used in calculating the counting efficiency in liquid-scintillation counting (LSC), which shows that Q(0)=1, and permits one to derive Q(E) as a function of the electron energy and the parameter kB. The coefficients are tabulated by applying a new empirical formula of Q(E) for kB values in the range between 0.001 and 0.20 gMeV sup - sup 1 cm sup - sup 2. We demonstrate the convenience of applying sup 3 H and sup 5 sup 4 Mn for beta-ray and electron capture standardizations, respectively.

  14. The determination of the optimum counting conditions for a ZnS(Ag) scintillation detector

    International Nuclear Information System (INIS)

    Djurasevic, M.M.; Kandic, A.B.; Novkovic, D.N; Vukanac, I.S. . E-mail address of corresponding author: mirad@vin.bg.ac.yu; Djurasevic, M.M.)

    2005-01-01

    The methods that use scintillation counting with ZnS(Ag) scintillation detector are widely used for gross alpha activity determination. The common criteria for the selection of optimum counting condition for a ZnS(Ag) scintillation detector do not consider simultaneously operating voltage and discrimination level variation. In presented method a relationship between voltage and discrimination level is derived for counting efficiency. (author)

  15. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  16. Study on quench effects in liquid scintillation counting during tritium measurements

    International Nuclear Information System (INIS)

    Ivana Jakonic; Jovana Nikolov; Natasa Todorovic; Miroslav Veskovic; Branislava Tenjovic

    2014-01-01

    Quench effects can cause a serious reduction in counting efficiency for a given sample/cocktail mixture in liquid scintillation counting (LSC) experiments. This paper presents a simple experiment performed in order to test the influence of quenching on the LSC efficiency of 3 H. The aim of this study was to investigate the behavior of several quench agents with different quench strengths (nitromethane, nitric acid, acetone, dimethyl-sulfoxide) added in different amounts to tritiated water in order to obtain standard sets for quench calibration curves. The OptiPhase HiSafe 2 and OptiPhase HiSafe 3 scintillation cocktails were used in this study in order to compare their quench resistance. Measurements were performed using a low-level LS counter (Wallac, Quantulus 1220). (author)

  17. Application of avalanche photodiodes for the measurement of actinides by alpha liquid scintillation counting

    International Nuclear Information System (INIS)

    Reboli, A.

    2005-10-01

    Alpha emitters analysis using liquid scintillation spectroscopy is often used when sensitivity and fast samples preparation are the important points. A more extensive use of this technique is until now limited by its poor resolution compared to alpha particle spectroscopy with semiconductor detectors. To improve the resolution and thus promote this method for the measurement of actinides in environment, we have tested silicon avalanche photodiodes (APD) as new detectors for scintillation photons. The set-up consists of a large area avalanche photodiode (16 mm diameter) coupled to a thin vial containing alpha-emitters within a liquid scintillation cocktail. After optimization of several parameters like bias voltage, temperature, counting geometry and composition of the scintillating cocktail, energy resolutions have been found to be better than those obtained with standard photomultiplier tubes (PMT): 5% (200 keV FWHM) for 232 Th and 4.2% (240 keV FWHM) for 236 Pu. Our results show that the improvement is due to less fluctuations associated with light collection since the spatial response of APDs is more uniform than that of PMTs. The expected gain on quantum efficiency (80% for APDs instead of 25% for PMTs) is nullified by a corresponding increase on electronic noise and excess noise factor. Significant better results are foreseen by using green scintillators (450 - 550 nm wavelengths region) with larger Stokes-shift and blue-enhanced APDs which reach their maximum quantum efficiency in this region. (author)

  18. Preparation of 45Ca(HDEHP)n and (CaH{sub 1}50{sub 2})2 samples for liquid scintillation counting, compared to 45caCl{sub 2} results; Preparacion de Ca (HDEHP)n y (C{sub 8}H{sub 1}50{sub 2})2 marcados con 45Ca y estudio comparativo con 4 5ca Cl2 en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L.; Arcos, J. M. los; Grau Malonda, A.

    1994-07-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethylhexanoate calcium salt, labelled with 45Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators,Toluene-alcohol, Dioxane-naphtalene, Hi safe II, Ultimate-Gold and Instagel, and compared to results obtained from a commercial solution of 4 5CaCl2. (Author) 7 refs.

  19. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  20. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

    International Nuclear Information System (INIS)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-01-01

    The radionuclide 68 Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of 68 Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ−γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. - Highlights: ► We standardized the positron emitter Ga-68 in a bilateral cooperation. ► We used several techniques, as coincidence, integral gamma and liquid scintillation. ► An efficiency comparison replaced a direct comparison of reference materials.

  2. Comparison of accelerator mass spectrometric measurement with liquid scintillation counting measurement for the determination of 14C in environmental samples

    International Nuclear Information System (INIS)

    Yasuike, Kaeko; Yamada, Yoshimune; Amano, Hikaru

    2010-01-01

    The concentrations of organically-bound 14 C in tree-ring cellulose of a Japanese Black Pine grown in Shika-machi (37.0 deg. N, 136.8 deg. E) and those of a Japanese Cedar grown in Kanazawa (36.5 deg. N, 136.7 deg. E), Japan, were analyzed for the ring-years from 1989 to 1998 by the accelerator mass spectrometric measurement. The results were compared with those of the same samples analyzed by the liquid scintillation counting measurement to determine the reliability of liquid scintillation counting measurement. An important result of this study is that the sensitivity and reproducibility of accelerator mass spectrometric measurement was almost equal to that of liquid scintillation counting measurement.

  3. The efficacy of biodegradable liquid scintillation counting cocktails

    International Nuclear Information System (INIS)

    Klein, R.C.; Gershey, E.L.

    1990-01-01

    Liquid scintillation counting (LSC) waste once accounted for ∼50% of the low-level radioactive wastes generated by academic and biomedial research. Strict regulations banning the land burial of organic liquids led the U.S. Nuclear Regulatory Commission to deregulate very low level LSC waste (10CFR20.306 of the Code of Federal Regulations) in 1981. Today, LSC waste containing ≤0.05 μCi/ml of 3 H or 14 C is generally incinerated as flammable liquid. Several manufacturers are now offering cocktails that contain long-chain and multiringed aromatic compounds that have not been identified as hazardous by the Environmental Protection Agency (EPA) under the Resource Conservation and Recovery Act (40CFR261) or the Clean Water Act (40CFR122). In addition to lower toxicity and higher flash points than their predecessors, these new cocktails are being advertised as biodegradable. Simple exclusion from the relatively short EPA lists of hazardous chemicals, however, may only reflect insufficient study. Five cocktail solvent families were identified by gas chromatography (GC) and GC/mass spectrometry: meta- and ortho-xylenes, trimethylbenzene isomers, linear alkylbenzenes, 1-phenyl-1-(3,4-xylyl)-ethane, and diisopropylnaphthalene. Cocktail efficiencies were determined for tritiated samples commonly found in biomedical research by the internal standard method

  4. Strontium-90 (90Sr) determination using liquid scintillation counting

    International Nuclear Information System (INIS)

    Cheberle, L.T.V.; Rosa, M.M.L.; Ferreira, M.T.; Taddei, M.H.T.

    2015-01-01

    This procedure describes a method for separation and measurement of strontium 90 Sr in water, soils, and biological samples. Water samples may be concentrated using evaporation or calcium phosphate coprecipitation. Soils and biological materials must be dissolved using wet digestion. Tracers and carriers must be added before the attack. Radioactive strontium is separated employing a specific resin before determination by liquid scintillation counting using the double energetic window method. The resin is used to concentrate strontium from samples. Stable strontium is used to monitor method yields and correct results to improve precision and accuracy. The presence of elemental strontium in the sample may bias the gravimetric yield determination. If it is suspected that natural strontium is present in the sample, its concentration should be determined by a suitable means (ICP), and the yield calculation properly modified. Sr-Spec resin with an 8M HNO 3 load solution is used to effectively remove 140 Ba and 40 K isotopes, as well as other interferences from the matrix. Tetravalent plutonium, neptunium, cerium and ruthenium, however, are not removed using nitric acid. The radiochemical procedure was tested using PROCORAD intercomparison exercises and PNI samples. (author)

  5. Determination of 90Sr by liquid scintillation counting

    International Nuclear Information System (INIS)

    Cerchetti, Maria L.; Aghazarian, V.P.

    2006-01-01

    99m Tc, the result of the radioactive decay of 99 Mo, is one of the most applied radioisotopes in nuclear medicine and is used in nuclear medicine as a radiopharmaceutical product. It is important to ensure 99 Mo quality in order to fit the 99m Tc quality specifications. The main objective was to obtain a technique for 90 Sr determination in 99 Mo and environmental samples. The purification of 90 Sr is performed by extraction chromatography where crown-ether resin (Sr-Spec, Eichrom) was used. The measurement of the 90 Sr activity is performed by Liquid Scintillation Counting (LSC) using the double windows method. This method permits the 90 Sr determination without waiting until radiochemical equilibrium 90 Sr / 90 Y has been reached. The recovery factor was determined by gamma spectrometry with 85 Sr, and by gravimetry with stable strontium carrier solution. The minimum detectable activity was 0,05 Bq. The recovery factor was the major contribution in the total uncertainty. (author)

  6. Optimisation of liquid scintillation counting conditions to determine low activity levels of tritium and radiostrontium in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Rauret, Gemma; Mestres, J.S.; Ribera, Merce; Rajadel, Pilar (Barcelona Univ. (Spain). Dept. de Quimica Analitica)

    1990-08-01

    An optimisation of the counting conditions for the measurement of aqueous solutions of tritium or radiostrontium using Insta-Gel II as scintillator is presented. The variables optimised were the window, the ratio of mass of sample to mass of scintillator and the total volume of the counting mixture. An optimisation function which takes into account each of these variables, the background and also the efficiency is proposed. The conditions established allow the lowest possible detection limit to be reached. For tritium, this value was compared with that obtained when the standard method for water analysis was applied. (author).

  7. The determination of 14CO2 in breath by liquid scintillation counting

    International Nuclear Information System (INIS)

    Ozker, K.; East, B.W.; Boddy, K.

    1977-03-01

    A sensitive method of sampling and measuring the specific activity of 14 CO 2 in expired breath in order to evaluate the metabolic pathways of 14 C-labelled compounds has been devised. 14 CO 2 is blown through a short plastic tube, attached to a drier, into a scintillation vial containing hyamine hydroxide and ethanol. 14 CO 2 was generated to the end-point of neutralization of hyamine hydroxide, indicated by the decolourisation of phenolphthalein. 14 CO 2 was counted after mixing the hyamine hydroxide and ethanol with 15ml toluene scintillation solution. The specific activity of 14 CO 2 from the samples was compared with that of solutions of known activity. The method is sensitive for clinical applications and can be performed at a patient's bedside. (U.K.)

  8. Poissonian and binomial models in radionuclide metrology by liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1990-01-01

    Binomial and Poissonian models developed for calculating the counting efficiency from a free parameter is analysed in this paper. This model have been applied to liquid scintillator counting systems with two or three photomultipliers. It is mathematically demostrated that both models are equivalent and that the counting efficiencies calculated either from one or the other model are identical. (Author)

  9. Automatic quench compensation for liquid scintillation counting system

    International Nuclear Information System (INIS)

    Nather, R.E.

    1978-01-01

    A method of automatic quench compensation is provided, where a reference measure of quench is taken on a sample prior to taking a sample count. The measure of quench is then compared with a reference voltage source which has been established to vary in proportion to the variation of the measure of quench with the level of a system parameter required to restore at least one isotope spectral energy endpoint substantially to a selected counting window discriminator level in order to determine the amount of adjustment of the system parameter required to restore the endpoint. This is followed by the appropriate adjustment of the system parameter required to restore the relative position of the discriminator windows and the sample spectrum and is followed in turn by taking a sample count

  10. Pulse-duration discrimination for increasing counting characteristic plateau and for improving counting rate stability of a scintillation counter

    International Nuclear Information System (INIS)

    Kuz'min, M.G.

    1977-01-01

    For greater stability of scintillation counters operation, discussed is the possibility for increasing the plateau and reducing its slope. Presented is the circuit for discrimination of the signal pulses from input pulses of a photomultiplier. The counting characteristics have been measured with the scintillation detectors being irradiated by different gamma sources ( 60 Co, 137 Cs, 241 Am) and without the source when the scintillation detector is shielded by a tungsten cylinder with a wall thickness of 23 mm. The comparison has revealed that discrimination in duration increase the plateau and reduces its slope. Proceeding from comparison of the noise characteristics, the relationship is found between the noise pulse number and gamma radiation energy. For better stability of the counting rate it is suggested to introduce into the scintillation counter the circuit for duration discrimination of the output pulses of a photomultiplier

  11. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  12. Counting efficiency for liquid scintillator systems with a single multiplier phototube

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1984-01-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs

  13. Some studies on extractive liquid scintillation counting for Th-234/P-234m

    International Nuclear Information System (INIS)

    Grudpan, K.; Singjanusong, P.; Punyodom, W.

    1990-01-01

    A study on solvent extraction for Th-234/Pa-234m by liquid scintillation counting has not been reported. This paper will report an application of the technique on such a study. In a hydrochloric acid solution of an uranyl salt, Pa-234m which is one of the daughters of U-238 can be separated by extraction into isobutyl methyl ketone (IBMK). Cerenkov counting was applied for the extraction investigation. Solvent extraction of Th-234/Pa-234m from an aqueous nitric acid solution by TOPO/PPO in toluene by using liquid scintillation counting will be described

  14. Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting

    International Nuclear Information System (INIS)

    Vaca, F.; Garcia-Leon, M.

    1998-01-01

    In this paper a complete and self-consistent method for 90 Sr determination in environmental samples is presented. It is based on the Cherenkov counting of 90 Y with a conventional liquid scintillation counter. The effects of color quenching on the counting efficiency and background are carefully studied. A working curve is presented which allows to quantify the correction in the counting efficiency depending on the color quenching strength. (orig.)

  15. Analytical method of Kr-85 determination, using cryogenic concentration and separation and liquid scintillation counting

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.; Grau Malonda, A.

    1983-01-01

    The method used in the Laboratory of the JEN for the determination of Kr-85 levels in gaseous effluents of nuclear power and in the atmosphere is described. Samples of air, collected in metallic cylinders, are introduced into a gas-solid chromatographic separation system which resolves Kr from the other air components. The separated Kr ia dissolved in a toluene based scintillation cocktail, and the Kr-85 content is determined by liquid scintillation counting. (Author)

  16. Liquid scintillation counting standardization of Na129I by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1996-01-01

    We describe a sample preparation procedure for liquid scintillation measurements of stable solution of Na''129I. The counting stability and spectral evolution of this solution is studied in HiSafe''tmII, Ultima-Gold''tm and Insta-Gel''r. The liquid scintillation measurements have been carried efficiencies lower than 0.4%. the solution has been standardized in terms of activity concentration to an overall uncertainty of 0.46% (k=1 )

  17. Method for determination of radon-222 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-06-01

    The procedure for the determination of radon-222 by liquid scintillation counting is quite specific for this radionuclide. Radon-222 is extracted readily from the water sample by an organic scintillant. The decay products of radon-222 will remain in the water phase whilst radon-222 will be extracted into the organic phase. Before measurement the sample is stored for three hours until equilibrium is reached between radon-222 and its alpha emitting decay products. The alpha activity from radon-222 and its decay products is measured in a liquid scintillation counter

  18. Measurement of scintillation decay curves by a single photon counting technique

    International Nuclear Information System (INIS)

    Noguchi, Tsutomu

    1978-01-01

    An improved apparatus suitable for the measurement of spectroscopic scintillation decay curves has been developed by combination of a single photon counting technique and a delayed coincidence method. The time resolution of the apparatus is improved up to 1.16 nsec (FWHM), which is obtained from the resolution function of the system for very weak Cherenkov light flashes. Systematic measurement of scintillation decay curves is made for liquid and crystal scintillators including PPO-toluene, PBD-xylene, PPO-POPOP-toluene, anthracene and stilbene. (auth.)

  19. Liquid Scintillation Counting - Packard Triple-Label Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Torretto, P. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-23

    The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

  20. Cherenkov radiation effects on counting efficiency in extremely quenched liquid scintillation samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.; Rodriguez Barquero, L.

    1993-01-01

    The CIEMAT/NIST tracer method has successfully standardized nuclides with diverse quench values and decay schemes in liquid scintillation counting. However, the counting efficiency is computed inaccurately for extremely quenched samples. This article shows that when samples are extremely quenched, the counting efficiency in high-energy beta-ray nuclides depends principally on the Cherenkov effect. A new technique is described for quench determination, which makes the measurement of counting efficiency possible when scintillation counting approaches zero. A new efficiency computation model for pure beta-ray nuclides is also described. The results of the model are tested experimentally for 89 Sr, 90 Y, 36 Cl and 204 Tl nuclides with independence of the quench level. (orig.)

  1. Optics study of liquid scintillation counting systems; Estudio de la Optica en sistemas de medida por centelle liquido

    Energy Technology Data Exchange (ETDEWEB)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-07-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  2. Evaluation of misplaced event count rate using a scintillation camera

    International Nuclear Information System (INIS)

    Yanagimoto, Shin-ichi; Tomomitsu, Tatsushi; Muranaka, Akira

    1985-01-01

    Misplaced event count rates were evaluated using an acryl scatter body of various thickness and a gamma camera. The count rate in the region of interest (ROI) within the camera view field, which was thought to represent part of the misplaced event count rate, increased as the thickness of the scatter body was increased to 5 cm, followed by a steep decline in the count rate. On the other hand, the ratio of the count rate in the ROI to the total count rate continuously increased as the thickness of the scatter body was increased. As the thickness of the scatter body was increased, the count rates increased, and the increments of increase were greater in the lower energy region of the photopeak than in the higher energy region. In ranges energy other than the photopeak, the influence of the scatter body on the count rate in the ROI was the greatest at 76 keV, which was the lowest energy we examined. (author)

  3. Well scintillation counting systems for nuclear medicine applications in developing countries

    International Nuclear Information System (INIS)

    1977-01-01

    This report of a consultants' meeting, organized by the Medical Applications Section of the Division of Life Sciences, IAEA, during the period 23-25 May 1977, examines well scintillation counting systems in the light of the requirements of laboratories in developing countries. It has three facets: 1) identification of the most rewarding applications of nuclear medicine techniques, 2) identification of favourable design attributes of instruments used in such applications, and 3) development of maintenance strategies to assure reliable performance of the instruments once put into service. Some characteristics of commercially available well scintillation counting systems are given

  4. Liquid scintillation counting efficiency in three photomultiplier systems. Pure electron capture

    International Nuclear Information System (INIS)

    Los Arcos, J. M.; Grau Carles, A.; Grau Malonda, A.

    1990-01-01

    The tables of counting efficiency as a function of the figure of merit for a liquid scintillation counting system working with three phototubes are presented. The evaluation has been carried out for a Toluene-based scintillator with 5, 10 and 15 ml column, and 19 different radionuclides decaying by pure electron capture: 37Ar 41Ca, 49V, 53 Mn, 55Fe, 59Ni, 68Ge 7iGe, 82Sr, 97Tc, 118Te, 131CS, 137La, 140Ca, 157Tb, 165Er, 193Pt, 194Hg, 205Pb. (Author) 22 refs

  5. Liquid scintillation counting of 3H-thymidine incorporated into rat lens DNA

    International Nuclear Information System (INIS)

    Soederberg, P.G.; Lindstroem, B.

    1990-01-01

    DNA synthesis in the lens has previously been localized by autoradiography following incorporation of 3 H-thymidine. For the quantification of DNA synthesis in the lens, pooling of lenses and extraction of the DNA for liquid scintillation counting, has formerly been adapted. In the present investigation a method has been developed for the extraction of the unincorporated tracer from whole lenses after short time incubation in a medium containing 3 H-thymidine. The 3 H-thymidine incorporated into individual lenses was then detected by liquid scintillation counting after dissolution of the lenses. The sources of the variation in the method are evaluated. (author)

  6. Fluorescent organic dyes as radiation converters in scintillation counting and laser techniques

    International Nuclear Information System (INIS)

    Guesten, H.

    1989-01-01

    PMP (1-phenyl-3-mesityl-2-pyrazoline) was selected as color quenching from the category of the sterically hindered 1,3-diphenyl-2-pyrazoline by means of comparative optimization between photo-physical and scintillation-spectroscopic and chemical properties and the costs of synthesis. It is applied in liquid scintillation detectors for the detection of β (T, C-14) and in large-volume liquid scintillators for the detection of neutrinos (Rutherford Lab.). (HP) [de

  7. Comparison of the efficacy of biodegradable and non-biodegradable scintillation liquids on the counting of tritium- and [14C]-labeled compounds

    Directory of Open Access Journals (Sweden)

    Medeiros R.B.

    2003-01-01

    Full Text Available The widespread use of ³H and 14C in research has generated a large volume of waste mixed with scintillation liquid, requiring an effective control and appropriate storage of liquid radioactive waste. In the present study, we compared the efficacy of three commercially available scintillation liquids, Optiphase HiSafe 3, Ultima-Gold(TM AB (biodegradable and Insta-Gel-XF (non-biodegradable, in terms of [14C]-glucose and [³H]-thymidine counting efficiency. We also analyzed the effect of the relative amount of water (1.6 to 50%, radioisotope concentration (0.1 to 100 nCi/ml, pH (2 to 10 and color of the solutions (samples containing 0.1 to 1.0 mg/ml of Trypan blue on the counting efficiency in the presence of these scintillation liquids. There were few significant differences in the efficiency of 14C and ³H counting obtained with biodegradable or non-biodegradable scintillation liquids. However, there was an 83 and 94% reduction in the efficiency of 14C and ³H counting, respectively, in samples colored with 1 mg/ml Trypan blue, but not with 0.1 mg/ml, independent of the scintillation liquid used. Considering the low cost of biodegradable scintillation cocktails and their efficacy, these results show that traditional hazardous scintillation fluids may be replaced with the new safe biodegradable fluids without impairment of ³H and 14C counting efficiency. The use of biodegradable scintillation cocktails minimizes both human and environmental exposure to hazardous solvents. In addition, some biodegradable scintillation liquids can be 40% less expensive than the traditional hazardous cocktails.

  8. Preparation of 'dead water' for low background liquid scintillation counting

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Niwa, Takeo; Kawai, Hiroshi

    1987-01-01

    'Dead water', low level tritiated water is indispensable to measure tritium concentration in environmental waters using a low background liquid scintillation counter. Water produced by combustion of natural gas, or deep sea water etc. are usually used for the above purpose. A new method of reducing tritium concentration in natural water has been introduced for preparation of 'dead water'. This method is to combine hydrogen-oxygen mixture produced by water electrolysis with hopcalite catalyzer at 700 deg C. Deep well water was electrolized up to 2/3 volume, and tritium concentration of recombined water was reduced to be about one third of that of the original one. (author)

  9. Rapid bioassay method for estimation of 90Sr in urine samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Chaudhary, Seema; Sawant, Pramilla D.

    2018-01-01

    Radiostrontium (Sr) is a by-product of the nuclear fission of uranium and plutonium in nuclear reactors and is an important radionuclide in spent nuclear fuel and radioactive waste. Rapid bioassay methods are required for estimating Sr in urine following internal contamination. Decision regarding medical intervention, if any can be based upon the results of urinalysis. The present method used at Bioassay Laboratory, Trombay is by Solid Extraction Chromatography (SEC) technique. The Sr separated from urine sample is precipitated as SrCO 3 and analyzed gravimetrically. However, gravimetric procedure is time consuming and therefore, in the present study, feasibility of Liquid Scintillation Counting for direct detection of radiostrontium in effluent was explored. The results obtained in the present study were compared with those obtained using gravimetric method

  10. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    International Nuclear Information System (INIS)

    Sosa, M.; Manjón, G.; Mantero, J.; García-Tenorio, R.

    2014-01-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ( 152 Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis

  11. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, M. [Departamento de Ingeniería Física, Campus León, Universidad de Guanajuato, 37150 León, Guanajuato (Mexico); Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Manjón, G., E-mail: manjon@us.es [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Mantero, J.; García-Tenorio, R. [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain)

    2014-05-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ({sup 152}Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis.

  12. Comparative characteristics of polystyrene scintillation strips

    International Nuclear Information System (INIS)

    Gapienko, V.A.; Denisov, A.G.; Mel'nikov, E.A.

    1992-01-01

    Results are provided for a study of the main characteristics of polystyrene scintillation strips with a cross-section of 200 x 10 mm with two different scintillation-additive compositions: 1.5% p-terphenyl + 0.01% POPOP and 1.5% p-terphenyl + 0.01% DBP. The mean light-attenuation lengths are 180 cm and 260 cm, respectively, for strips with POPOP and DBP. The emittances of the polystyrene scintillators with DBP and POPOP additives have a ratio of 0.8:1.0 as recorded by an FEU-110 photomultiplier. 2 refs., 1 fig., 2 tabs

  13. Liquid Scintillation counting Standardization of 22 NaCl by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-09-01

    We describe a procedure for preparing a stable solution of ''22 NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4/% and an overall uncertainty of 0.35%

  14. Liquid Scintillation Counting Standardization of 22NaCl by te CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-01-01

    We describe a procedure for preparing a stable solution of ''22NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4 % and an overall uncertainty of 0.35 %. (Author) 4 refs

  15. Estimating the standard deviation for 222Rn scintillation counting - a note concerning the paper by Sarmiento et al

    International Nuclear Information System (INIS)

    Key, R.M.

    1977-01-01

    In a recent report Sarmiento et al.(1976) presented a method for estimating the statistical error associated with 222 Rn scintillation counting. Because of certain approximations, the method is less accurate than that of an earlier work by Lucas and Woodward (1964). The Sarmiento method and the Lucas method are compared, and the magnitude of errors incurred using the approximations are determined. For counting times greater than 300 minutes, the disadvantage of the slight inaccuracies of the Sarmiento method are outweighed by the advantage of easier calculation. (Auth.)

  16. A new analytical method for 32P. Liquid scintillation counting with solvent extraction

    International Nuclear Information System (INIS)

    Liyanage, J.A.; Yonezawa, C.

    2003-01-01

    Trace determination of phosphorus has been studied using neutron activation analysis. Radioactivity of 32 P in tri-n-octylamine phosphomolybdate complex was measured using liquid scintillation counting by extracting the complex into xylene. Phosphorus can be quantitatively determined from 16.7 to 600 μg/10 ml by using the radiochemical analysis method described. (author)

  17. Study of alternative methods for the management of liquid scintillation counting wastes

    International Nuclear Information System (INIS)

    Roche-Farmer, L.

    1980-02-01

    The Nuclear Engineering Waste Disposal Site in Richland, Washington, is the only radioactive waste disposal facility that will accept liquid scintillation counting wastes (LSCW) for disposal. That site is scheduled to discontinue receiving LSCW by the end of 1982. This document explores alternatives presently available for management of LSCW: evaporation, distillation, solidification, conversion, and combustion

  18. Planktonic primary production evaluation by means of the 14C method with liquid scintillation counting

    International Nuclear Information System (INIS)

    Frangopol, T.P.; Bologa, S.A.

    1979-05-01

    Preliminary results on the planktonic primary production obtained for the first time with the 14 C method off the Romanian Black Sea coast (1977, 1978) and in the Sinoe, Mamaia and Bicaz lakes (1978) are presented, along with a review of this method with special reference to liquid scintillation counting. 140 Refs. (author)

  19. Determination of plutonium-241 by liquid scintillation counting method and its application to environmental samples

    International Nuclear Information System (INIS)

    Watanabe, Miki; Amano, Hikaru

    1997-03-01

    Radionuclides are usually measured by gross counting mode in liquid scintillator counting (LSC) which measures both α and β pulses. This method can easily measure radioactivities, but its background counting is high. Recently reported α-β pulse shape discrimination method (α-β PSD method) in LSC which distinguishes α pulses from β pulses, shows low background counting, so it makes the detection limit lower. The aim of this research is to develop the best method for the determination of 241 Pu which is β-emitter, and Pu isotopes of α-emitters which have long half-lives and stay long in animal body. In this research, two LSC machines was carried out in different scintillators, vial volumes, measurement modes and so on. The following things were found. 1. The liquid scintillator based on naphthalene is proved to be the best separator of α-ray from β-ray, because it acts quickly in energy translation procedure between solvent and aromatic compounds. 2. α-β PSD method makes the background counting rate ten times lower than usual method. It makes the measurement performance better. 3. It is possible to determine 241 Pu in environmental samples around Chernobyl by the combination of LSC and radiochemical separation methods. (author)

  20. Accurate disintegration-rate measurement of 55Fe by liquid scintillation counting

    International Nuclear Information System (INIS)

    Steyn, J.; Oberholzer, P.; Botha, S.M.

    1979-01-01

    A method involving liquid scintillation counting is described for the accurate measurement of disintegration rate of 55 Fe. The method is based on the use of calculated efficiency functions together with either of the nuclides 54 Mn and 51 Cr as internal standards for measurement of counting efficiencies by coincidence counting. The method was used by the NAC during a recent international intercomparison of radioactivity measurements, and a summary of the results obtained by nine participating laboratories is presented. A spread in results of several percent is evident [af

  1. Determination of 226Ra and 224Ra in drinking waters by liquid scintillation counting

    International Nuclear Information System (INIS)

    Manjon, G.; Vioque, I.; Moreno, H.; Garcia-Tenorio, R.; Garcia-Leon, M.

    1997-01-01

    A method for the determination of Ra-isotopes in water samples has been developed. Ra is coprecipitated with Ba as sulphate. The precipitate is then dissolved with EDTA and counted with a liquid scintillation system after mixing with a scintillation cocktail. The study of the temporal evolution of the separated activity gives the isotopic composition of the sample, i.e. the 224 Ra and 226 Ra contribution to the total activity. The method has been applied to some Spanish drinking waters. (author)

  2. Measurement of radionuclides using ion chromatography and flow-cell scintillation counting with pulse shape discrimination

    International Nuclear Information System (INIS)

    DeVol, T.A.; Fjeld, R.A.

    1995-01-01

    A project has been initiated at Clemson Univ. to develop a HPLC/flow- cell system for analysis of non-gamma emitting radionuclides in environmental samples; an important component is development of a low background flow-cell detector that counts alpha and beta particles separately through pulse shape discrimination. Objective of the work presented here is to provide preliminary results of an evaluation of the following scintillators: CaF 2 :Eu, scintillating glass, and BaF 2 . Slightly acidic aqueous solutions of the alpha emitter 233 U and the beta emitter 45 Ca were used. Detection efficiencies and minimum detectable activities were determined

  3. Estimation of low level gross alpha activities in the radioactive effluent using liquid scintillation counting technique

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Johnson, Bella E.; Singh, Sanjay; Babu, D.A.R.

    2012-01-01

    A technique has been developed for simultaneous measurement of gross alpha and gross beta activity concentration in low level liquid effluent samples in presence of higher activity concentrations of tritium. For this purpose, alpha beta discriminating Pulse Shape Analysis Liquid Scintillation Counting (LSC) technique was used. Main advantages of this technique are easy sample preparation, rapid measurement and higher sensitivity. The calibration methodology for Quantulus1220 LSC based on PSA technique using 241 Am and 90 Sr/ 90 Y as alpha and beta standards respectively was described in detail. LSC technique was validated by measuring alpha and beta activity concentrations in test samples with known amount of 241 Am and 90 Sr/ 90 Y activities spiked in distilled water. The results obtained by LSC technique were compared with conventional planchet counting methods such as ZnS(Ag) and end window GM detectors. The gross alpha and gross beta activity concentrations in spiked samples, obtained by LSC technique were found to be within ±5% of the reference values. (author)

  4. Counting efficiencies by liquid scintillation counting. Single isomeric transitions; Eficiencia de recuento por centelleo liquido. Transiciones isomericas simples

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1995-07-01

    In this work we present liquid scintillation counting efficiency tables for several radionuclides with single isomeric transitions, in which electron conversion and gamma emission processes are competitive. We study the radionuclides: 58mCo, 77mSe, 79mBr, 87mSr, S9mY, 93mNb, 103mRh, 107mAg, 109mAg, 113mIn, 131mXe, I33mXe, 135raBa, 137mBa, 167raEr, for two different scintillators, Ultima-Gold and Insta-Gel. We consider volumes of 10 and 15 mL for Ultima Gold, and 15 mL for Insta-Gel. (Author) 18 refs.

  5. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  6. Triton X-100 as a complete liquid scintillation cocktail for counting aqueous solutions and ionic nutrient salts

    International Nuclear Information System (INIS)

    Reed, D.W.

    1984-01-01

    Triton X-100, used alone, was found to act as a complete liquid scintillation cocktail. Triton X-100 acted as a scintillator and the effect was not due to Cerenkov radiation. A variety of other commercially available surfactants also acted as scintillators, but with different levels of efficiency. Triton X-100/water combinations were suitable for counting aqueous solutions of 33 P and 86 Rb and the count rate was stable over extended periods of time. Triton X-100/toluene combinations also yielded high counting efficiencies. Triton X-100 was more sensitive to quenching than standard cocktails containing fluors. (author)

  7. Method and apparstus for determining random coincidence count rate in a scintillation counter utilizing the coincidence technique

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A method and apparatus for the reliable determination of a random coincidence count attributable to chance coincidences of single-photon events which are each detected in only a single detector of a scintillation counter utilizing two detectors in a coincidence counting technique are described. A firstdelay device is employed to delay output pulses from one detector, and then the delayed signal is compared with the undelayed signal from the other detector in a coincidence circuit, to obtain an approximate random coincidence count. The output of the coincidence circuit is applied to an anti-coincidence circuit, where it is corrected by elimination of pulses coincident with, and attributable to, conventionally detected real coincidences, and by elimination of pulses coincident with, and attributable to, real coincidences that have been delayed by a second delay device having the same time parameter as the first. 8 claims

  8. Standardization of 40 K by liquid scintillation counting. Determination of the half-life

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1997-01-01

    The relative abundance of the natural radioisotope ''40 K in environmental samples frequently generates interferences in low activity measurements. In the present study we propose the determination of ''40 K by the CIEMAT/NIST method. On this context, the verification of ''40 K half-life is required. We present a half-life value obtained by liquid scintillation counting in excellent agreement with those reported in the literature. (Author)

  9. Influence of atomic and nuclear constants on the counting efficiency for 55Fe in liquid scintillators

    International Nuclear Information System (INIS)

    Fernandez, A.; Grau, A.; Arcos, J. M. los

    1985-01-01

    In this paper one considers the influence of the different parameters on the determination of the uncertainty of the detection efficiency for 55 F e when the counting technique of liquid scintillation is applied. The following parameters are considered: the relative probabilities of X and Auger emission so as their corresponding energies, the fluorescence yields W K and W L , and the non-interaction probabilities of the emitted X photons. (Author) 11 refs

  10. Testing the count rate performance of the scintillation camera by exponential attenuation: Decaying source; Multiple filters

    International Nuclear Information System (INIS)

    Adams, R.; Mena, I.

    1988-01-01

    An algorithm and two fortrAN programs have been developed to evaluate the count rate performance of scintillation cameras from count rates reduced exponentially, either by a decaying source or by filtration. The first method is used with short-lived radionuclides such as 191 /sup m/Ir or 191 /sup m/Au. The second implements a National Electrical Manufacturers' Association (NEMA) protocol in which the count rate from a source of 191 /sup m/Tc is attenuated by a varying number of copper filters stacked over it. The count rate at each data point is corrected for deadtime loss after assigning an arbitrary deadtime (tau). A second-order polynomial equation is fitted to the logarithms of net count rate values: ln(R) = A+BT+CT 2 where R is the net corrected count rate (cps), and T is the elapsed time (or the filter thickness in the NEMA method). Depending on C, tau is incremented or decremented iteratively, and the count rate corrections and curve fittings are repeated until C approaches zero, indicating a correct value of the deadtime (tau). The program then plots the measured count rate versus the corrected count rate values

  11. Determination of 90SR in food using extraction chromatography and LSC - Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    Temba, Eliane S.C.; Amaral, Angela M.; Reis Junior, Aluisio S.; Monteiro, Roberto P.G.

    2013-01-01

    A methodology for the determination of 90 Sr in food is described. The procedure involved a preliminary freeze-drying of the samples followed by dry-ashing and sample digestion. The separation procedure was carried out using extraction chromatography with Sr Resin, from Eichrom, and 90 Sr was measured by liquid scintillation counting (LSC). A certified reference material, IAEA-375, was analyzed in order to evaluate the reliability of the method, and the results showed good agreement between the measured and certified values. The chemical yield was above 90% and the typical counting efficiency was 82%. The calculated limit of detection was 4.8 x 10 -3 Bq g -1 . (author)

  12. Determination of radon in indoor air in Quebec by liquid scintillation counting in ortho-xylene

    Energy Technology Data Exchange (ETDEWEB)

    Chah, B; Zikovsky, L; Champagne, P [Ecole Polytechnique, Montreal, PQ (Canada)

    1992-01-01

    A new method for the determination of radon in air has been developed. it is based on low temperature absorption of radon in ortho-xylene followed by liquid scintillation counting. The method is reasonably fast and sensitive enough to analyse air without precipitation. The detection limit at the 95% confidence level for a 20 l air sample and 1 h counting time is 2 mBql{sup -1}. Radon concentrations measured in indoor air in Quebec varied from 7 to 162 mBql{sup -1}. (Author).

  13. Liquid organic scintillator in a polymerizable emulsion, its application to radioactive counting and process for its destruction

    International Nuclear Information System (INIS)

    O'Brien, R.E.; Krieger, J.K.

    1981-01-01

    Scintillation organic liquid mixture for performing very efficient counts on compound solutions labelled with a radioactive indicator containing up to 10% water by volume and which is easily polymerizable into a solid substance, in order to facilitate its elimination. The mixture includes a polymerizable organic solvent, a solubilizing agent, an intermediate solvent and an organic scintillator [fr

  14. Standardization of iodine-129 by the TDCR liquid scintillation method and 4π β-γ coincidence counting

    Science.gov (United States)

    Cassette, P.; Bouchard, J.; Chauvenet, B.

    1994-01-01

    Iodine-129 is a long-lived fission product, with physical and chemical properties that make it a good candidate for evaluating the environmental impact of the nuclear energy fuel cycle. To avoid solid source preparation problems, liquid scintillation has been used to standardize this nuclide for a EUROMET intercomparison. Two methods were used to measure the iodine-129 activity: triple-to-double-coincidence ratio liquid scintillation counting and 4π β-γ coincidence counting; the results are in good agreement.

  15. Role of quenching on alpha/beta separation in liquid scintillation counting for several high capacity cocktails

    International Nuclear Information System (INIS)

    Pujol, L.; Sanchez-Cabeza, J.-A.

    1997-01-01

    The optimization of alpha/beta separation in liquid scintillation using pulse shape analysis is convenient for the simultaneous determination of alpha and beta emitters in natural water and other samples. In this work, alpha/beta separation was studied for different scintillant/vial combinations and it was observed that both the optimum pulse shape discrimination level and the total interference value (that is, the summed relative interference between alpha and beta spectra) were dependent on the sample quenching and independent of the scintillant/vial combination. These results provide a simple method for modifying the counting configuration, such as a change in the cocktail, vial or sample characteristics, without the need to perform exhaustive parameter optimizations. Also, it was observed that, for our counting conditions, the combination of Ultima Gold AB scintillation cocktail with Zinsser low diffusion vials presented the lowest total interference, namely 0.94 ± 0.28%, which is insignificant for the counting of environmental samples. (Author)

  16. Radioactivity measurement of barium carbonate [14C] by liquid scintillation counting

    International Nuclear Information System (INIS)

    Kobayashi, Katsutoshi; Hoizumi, Kiyoshi

    1985-03-01

    Two methods of sample preparation for the measurement of specific activity of BaCO 3 [ 14 C] by external standard method in liquid scintillation counting were studied. BaCO 3 [ 14 C] was decomposed by perchloric acid solution and generated CO 2 [ 14 C] was absorbed by ethylene glycol monomethyl ether solution of monoethanolamine as the method 1 or aqueous sodium hydroxide as the method 2. In order to prepare the sample solution of adequate radioactivity concentration, these carbonate solutions by the methods 1 and 2 were diluted with the suitable organic solvent and distilled water respectively. One tenth millilitre of these sample solutions was added into 10 ml of PPO-toluene scintillator containing 0.1 ml of monoethanolamine in a counting vial and homogeneously dissolved with ethyl alcohol. The results of the radioactivity measurement of BaCO 3 [ 14 C] based on the different method agreed within 5 % and the counting rate was found to be stable for as long as 7 deays or more. Both methods of preparation are suitable for the routine measurement because of their simplicity and feasibility. In the case of method 2, the liquid radioactive waste is almost inorganic solution and recovery in the form of BaCO 3 [ 14 C] is easily performed, so that this method is very advantageous from the view point of the radioactive waste treatement. (author)

  17. Age determination of trace plutonium using liquid scintillation counting and α-spectrometry

    International Nuclear Information System (INIS)

    Chen Yan; Chang Zhiyuan; Zhao Yonggang; Li Jinghuai; Shu Fujun

    2010-01-01

    Liquid scintillation counting combined with α-spectrometry through measuring 241 Pu/ 241 Am ratio to determine the age of trace Pu was studied. The technique was explored for the age determination of nanogram grade Pu sample on the basis of Pu/Am separation. The ages of two Pu samples-one with known and the other with unknown age were determined by the method. The determined age by the method is in agreement with the reference value. The established method for determining the age of trace Pu can be adopted in the verification activities of nuclear safeguards and nuclear arms control. (authors)

  18. Isolation and activity determination of 99Tc in nuclear waste by liquid scintillation counting

    International Nuclear Information System (INIS)

    Reis Junior, Aluisio S.; Temba, Eliane S.C.; Kastner, Geraldo F.; Monteiro, Roberto P.G.

    2011-01-01

    A radiochemical separation and purification for technetium was proposed for radioactive waste in which rhenium is to be used as a yield monitor. The separation was performed by anion exchange chromatography and the purification was performed by extraction chromatography using a TEVA resin.The determination of 99 Tc was by liquid scintillation counting and rhenium was activated by Triga Mark 1 research reactor and measured by gamma spectrometry. Some real samples of nuclear waste such as evaporator concentrate and filter were analysed. The chemical recovery determined using rhenium as tracer was around 90 %. (author)

  19. Determination of Np, Pu and Am in high level radioactive waste with extraction-liquid scintillation counting

    International Nuclear Information System (INIS)

    Yang Dazhu; Zhu Yongjun; Jiao Rongzhou

    1994-01-01

    A new method for the determination of transuranium elements, Np, Pu and Am with extraction-liquid scintillation counting has been studied systematically. Procedures for the separation of Pu and Am by HDEHP-TRPO extraction and for the separation of Np by TTA-TiOA extraction have been developed, by which the recovery of Np, Pu and Am is 97%, 99% and 99%, respectively, and the decontamination factors for the major fission products ( 90 Sr, 137 Cs etc.) are 10 4 -10 6 . Pulse shape discrimination (PSD) technique has been introduced to liquid scintillation counting, by which the counting efficiency of α-activity is >99% and the rejection of β-counts is >99.95%. This new method, combining extraction and pulse shape discrimination with liquid scintillation technique, has been successfully applied to the assay of Np, Pu and Am in high level radioactive waste. (author) 7 refs.; 7 figs.; 4 tabs

  20. Virtual point detector: On the interpolation and extrapolation of scintillation detectors counting efficiencies

    International Nuclear Information System (INIS)

    Presler, Oren; German, Uzi; Pushkarsky, Vitaly; Alfassi, Zeev B.

    2006-01-01

    The concept of transforming the detector volume to a virtual point detector, in order to facilitate efficiency evaluations for different source locations, was proposed in the past for HPGe and Ge(Li) detectors. The validity of this model for NaI(Tl) and BGO scintillation detectors was studied in the present work. It was found that for both scintillation detectors, the point detector model does not seem to fit too well to the experimental data, for the whole range of source-to-detector distances; however, for source-to-detector cap distances larger than 4 cm, the accuracy was found to be high. A two-parameter polynomial expression describing the dependence of the normalized count rate versus the source-to-detector distance was fitted to the experimental data. For this fit, the maximum deviations are up to about 12%. These deviations are much smaller than the values obtained by applying the virtual point concept, even for distances greater than 4 cm, thus the polynomial fitting is to be preferred for scintillation detectors

  1. QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting.

    Science.gov (United States)

    Cassette, Philippe

    2016-03-01

    In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ(2) minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. SCINFI, a program to calculate the standardization curve in liquid scintillation counting; SCINFI, un programa para calcular la curva de calibracion eficiencia-extincion en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1984-07-01

    A code, SCINFI, was developed, written in BASIC, to compute the efficiency- quench standardization curve for any radionuclide. The program requires the standardization curve for 3H and the polynomial relations between counting efficiency and figure of merit for both 3H and the problem (e.g. 14{sup C}). The program is applied to the computation of the efficiency-quench standardization curve for 14{sup c}. Five different liquid scintillation spectrometers and two scintillator solutions have bean checked. The computation results are compared with the experimental values obtained with a set of 14{sup c} standardized samples. (Author)

  3. Basic principles of scintillation counting; Principes de Base du Comptage par Scintillations; Osnovnye printsipy stsintillyatsij; Principios fundamentales del recuento con aparatos de centelleo

    Energy Technology Data Exchange (ETDEWEB)

    Johns, H E; Cederlund, J F [Ontario Cancer Institute, Toronto (Canada)

    1959-07-01

    The effect of the energy of radiation, the crystal size, the collimation of the beam and scattering on the pulse-height distribution produced by monoenergetic radiation will be discussed. These aspects will be related to scintillation scanning. The effects of voltage on the operation of photomultiplier s and so-called plateaus will be dealt with. Glow-transfer tubes for counting will be dealt with and a useful substraction circuit for comparing the counting rate from two separate scintillation counters will be presented. (author) [French] Les auteurs examineront l'effet de l'energie du rayonnement, de la dimension du cristal, de la collimation du faisceau et de la diffusion sur la repartition de l'amplitude des impulsions dues au rayonnement monoenergetique, en rattachant l'etude de ces questions a l'exploration par scintillations. Ils etudieront egalement les effets de la tension sur le fonctionnement des photomultiplicateurs et des , ainsi que l'utilisation de pour le comptage; ils presenteront enfin un circuit de soustraction utile servant a comparer le taux de comptage de deux scintillometres distincts. (author) [Spanish] Los autores estudiaran el efecto que la energia de la radiacion, el tamano del cristal, la colimacion del haz y la dispersion ejercen sobre la distribucion de la amplitud de los impulsos debida a la radiacion monoenergetica, relacionando todas estas cuestiones con la exploracion mediante aparatos de centelleo. Examinaran tambien la influencia de las variaciones de tension sobre el funcionamiento de los fotomultiplicadores y sobre las denominadas , asi como los tubos luminiscentes de transmision para el recuento; por ultimo, presentaran un circuito de sustraccion que sirve para comparar el indice de recuento de dos contadores de centelleo distintos. (author) [Russian] Budet obsuzhdat'sya vliyanie ehnergii izlucheniya, velichiny kristalla, kollimirovaniya lucha i, nakonets, rasseyaniya na amplitudnoe

  4. Sensitive and transportable gadolinium-core plastic scintillator sphere for neutron detection and counting

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Carrel, Frédérick; Corre, Gwenolé; Normand, Stéphane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France); Méchin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 14050 Caen (France); Hamel, Matthieu [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France)

    2016-08-21

    Neutron detection forms a critical branch of nuclear-related issues, currently driven by the search for competitive alternative technologies to neutron counters based on the helium-3 isotope. The deployment of plastic scintillators shows a high potential for efficient detectors, safer and more reliable than liquids, more easily scalable and cost-effective than inorganic. In the meantime, natural gadolinium, through its 155 and mostly 157 isotopes, presents an exceptionally high interaction probability with thermal neutrons. This paper introduces a dual system including a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. Incident fast neutrons are thermalized by the scintillator shell and then may be captured with a significant probability by gadolinium 155 and 157 nuclei in the core. The deposition of a sufficient fraction of the capture high-energy prompt gamma signature inside the scintillator shell will then allow discrimination from background radiations by energy threshold, and therefore neutron detection. The scaling of the system with the Monte Carlo MCNPX2.7 code was carried out according to a tradeoff between the moderation of incident fast neutrons and the probability of slow neutron capture by a moderate-cost metal gadolinium core. Based on the parameters extracted from simulation, a first laboratory prototype for the assessment of the detection method principle has been synthetized. The robustness and sensitivity of the neutron detection principle are then assessed by counting measurement experiments. Experimental results confirm the potential for a stable, highly sensitive, transportable and cost-efficient neutron detector and orientate future investigation toward promising axes.

  5. A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors

    International Nuclear Information System (INIS)

    Gamage, Kelum A.A.; Joyce, Malcolm J.; Cave, Frank D.

    2013-06-01

    Neutron coincidence counting is an established, nondestructive method for the qualitative and quantitative analysis of nuclear materials. Several even-numbered nuclei of the actinide isotopes, and especially even-numbered plutonium isotopes, undergo spontaneous fission, resulting in the emission of neutrons which are correlated in time. The characteristics of this i.e. the multiplicity can be used to identify each isotope in question. Similarly, the corresponding characteristics of isotopes that are susceptible to stimulated fission are somewhat isotope-related, and also dependent on the energy of the incident neutron that stimulates the fission event, and this can hence be used to identify and quantify isotopes also. Most of the neutron coincidence counters currently used are based on 3 He gas tubes. In the 3 He-filled gas proportional-counter, the (n, p) reaction is largely responsible for the detection of slow neutrons and hence neutrons have to be slowed down to thermal energies. As a result, moderator and shielding materials are essential components of many systems designed to assess quantities of fissile materials. The use of a moderator, however, extends the die-away time of the detector necessitating a larger coincidence window and, further, 3 He is now in short supply and expensive. In this paper, a simulation based on the Monte Carlo method is described which has been performed using MCNPX 2.6.0, to model the geometry of a sector-shaped liquid scintillation detector in response to coincident neutron events. The detection of neutrons from a mixed-oxide (MOX) fuel pellet using an organic liquid scintillator has been simulated for different thicknesses of scintillators. In this new neutron detector, a layer of lead has been used to reduce the gamma-ray fluence reaching the scintillator. The effect of lead for neutron detection has also been estimated by considering different thicknesses of lead layers. (authors)

  6. Sensitive and transportable gadolinium-core plastic scintillator sphere for neutron detection and counting

    International Nuclear Information System (INIS)

    Dumazert, Jonathan; Coulon, Romain; Carrel, Frédérick; Corre, Gwenolé; Normand, Stéphane; Méchin, Laurence; Hamel, Matthieu

    2016-01-01

    Neutron detection forms a critical branch of nuclear-related issues, currently driven by the search for competitive alternative technologies to neutron counters based on the helium-3 isotope. The deployment of plastic scintillators shows a high potential for efficient detectors, safer and more reliable than liquids, more easily scalable and cost-effective than inorganic. In the meantime, natural gadolinium, through its 155 and mostly 157 isotopes, presents an exceptionally high interaction probability with thermal neutrons. This paper introduces a dual system including a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. Incident fast neutrons are thermalized by the scintillator shell and then may be captured with a significant probability by gadolinium 155 and 157 nuclei in the core. The deposition of a sufficient fraction of the capture high-energy prompt gamma signature inside the scintillator shell will then allow discrimination from background radiations by energy threshold, and therefore neutron detection. The scaling of the system with the Monte Carlo MCNPX2.7 code was carried out according to a tradeoff between the moderation of incident fast neutrons and the probability of slow neutron capture by a moderate-cost metal gadolinium core. Based on the parameters extracted from simulation, a first laboratory prototype for the assessment of the detection method principle has been synthetized. The robustness and sensitivity of the neutron detection principle are then assessed by counting measurement experiments. Experimental results confirm the potential for a stable, highly sensitive, transportable and cost-efficient neutron detector and orientate future investigation toward promising axes.

  7. Use of liquid scintillation counting for quantitative analysis of volatile organic compounds in batch isotherm analysis

    International Nuclear Information System (INIS)

    Wickman, D.C.

    1987-01-01

    An estimate of how rapidly hazardous wastes move through subsurface soils via ground water is important to predict the location and concentration of the contaminant plume vs. time. The contaminated ground water system may be viewed as an HPLC column with the organic components of the waste in adsorption/desorption equilibrium with the subsurface soil. The batch isotherm method was chosen to determine the equilibrium constant between trichloroethylene, o-dichlorobenzene, 1-methyl naphthalene and aquifer materials obtained from various locations around the country. Liquid Scintillation counting has been found to be an excellent technique for batch isotherm analysis; using 14C labeled compounds, it affords unattended analysis, accuracy at very low concentrations and rapid data reduction. Ten ml serum containing about 5 ml water and a known weight of soil (approximately 2 grams) were spiked with the labeled solution to yield organic solute concentrations in the range of 0.02-1.0 mg/1. Six different concentrations were used. After spiking, the bottles were filled to the top with water and crimp sealed with teflon coated septa. All soil containing bottles were then rotated at 50 rpm and 22 degrees Celsius. Twenty-four hours later the bottles were uncapped and a 1.4 ml aliquot was removed and placed in scintillation cocktail and counted

  8. Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

    Energy Technology Data Exchange (ETDEWEB)

    Varlam, C.; Vagner, I.; Faurescu, I.; Faurescu, D. [National Institute for Cryogenics and Isotopic Technologies, Valcea (Romania)

    2015-03-15

    In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ({sup 14}C from organically compounds, {sup 36}Cl as chloride and free chlorine, {sup 40}K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}), lyophilization, chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization.

  9. A scheme for recycling of used liquid scintillation counting cocktail for tritium analysis

    International Nuclear Information System (INIS)

    Gocher, A.K.; Tailor, S.P.; Tiwari, S.N.; Ravi, P.M.; Tripathi, R.M.

    2018-01-01

    Ultima Gold LLT TM is a ready to use scintillation cocktail used for estimation of tritium activity in various water sample collected from Rawatbhata Rajasthan Site environment up to 30 km radial distance. The present study explores the possibility of re-using the cocktail used in non detect (BDL) samples for counting of high active samples. Results of tritium standard counted with used cocktail (UC) was within ±10 % variation w.r.t fresh Ultima gold scintillation cocktail. Also results of high active samples prepared using 20 ml Used Cocktail (UC) and 1 ml sample (20 ml UC: 1ml aq. sample) were found in the range -7% to +11.1% w.r.t same sample prepared using fresh Ultima Gold. Used cocktail (UC) can be reused for tritium activity estimation of high active samples. Re-using of used cocktail will ultimately reduce the cocktail consumption, reduce the operational cost and reduce the quantity of waste cocktail disposal to the environment

  10. Optimised method for the routine determination of Technetium-99 in environmental samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wigley, F.; Warwick, P.E.; Croudace, I.W.; Caborn, J.; Sanchez, A.L.

    1999-01-01

    A method has been developed for the routine determination of 99 Tc in a range of environmental matrices using 99m Tc (t 1/2 =6.06 h) as an internal yield monitor. Samples are ignited stepwise to 550C and the 99 Tc is extracted from the ignited residue with 8 M nitric acid. Many contaminants are co-precipitated with Fe(OH) 3 and the Tc in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of Tc from Ru is achieved by extraction of Tc into 5% tri-n-octylamine in xylene from 2 M sulphuric acid. The xylene fraction is mixed directly with a commercial liquid scintillant cocktail. The chemical yield is determined through the measurement of 99m Tc by gamma spectrometry and the 99 Tc activity is measured using liquid scintillation counting after a further two weeks to allow decay of the 99m Tc activity. Typical recoveries for this method are in the order 70-95%. The method has a detection limit of 1.7 Bq kg -1 based on a 2 h count time and a 10 g sample size. The chemical separation for 24 samples of sediment or marine biota can be completed by one analyst in a working week. A further week is required to allow the samples to decay before determination. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  11. Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

    International Nuclear Information System (INIS)

    Varlam, C.; Vagner, I.; Faurescu, I.; Faurescu, D.

    2015-01-01

    In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ( 14 C from organically compounds, 36 Cl as chloride and free chlorine, 40 K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na 2 O 2 and KMnO 4 ), lyophilization, chemical treatment (Na 2 O 2 and KMnO 4 ) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization

  12. Liquid scintillation counting standardization of ''125 I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''125 I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%

  13. Liquid scintillation counting standardization of 125I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''I25I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%. (Author) 14 refs

  14. Problems associated with scintillation counting of NaH14CO3 and gel suspension counting of Ba14CO3

    International Nuclear Information System (INIS)

    MacRae, J.C.; Wilson, S.

    1978-01-01

    Liquid NaH 14 CO 3 was assayed in emulsion-type (NE260 and Unisolve) and dioxan-based (NE250) scintillation cocktails contained in glass or polyethylene vials kept at 2 0 or 24-30 0 C. Different particle size ranges of standard Ba 14 CO 3 were assayed by gel suspension counting in Cabosil scintillation cocktail and in NE260 following solubilisation in EDTA-tetrasodium salt. Initial detectable activities of NaH 14 CO 3 in glass and polyethylene vials in NE250, NE260 and Unisolve were 97 and 96, 68 and 83, 71 and 89% of the true value respectively. Subsequent losses of activity over 7 days with the emulsion-type scintillators was greater from the polyethylene vials. Addition of phenylethylamine to the NE260 and Unisolve cocktails gave the true activity levels for all vials with no loss of activity over 6 days. When different particle size ranges of Standard Ba 14 CO 3 were suspended in Cabosil scintillation cocktail there was considerable variation in counting efficiency (77-88%) with little relationship between particle size and counting efficiency. The relationship between counting efficiency and channels ratio was not sufficiently precise for predictive purposes. Solubilisation of Ba 14 CO 3 in EDTA-tetrasodium salt gave similar counting efficiency and channels ratio values for all samples. (U.K.)

  15. Statistical tests to compare motif count exceptionalities

    Directory of Open Access Journals (Sweden)

    Vandewalle Vincent

    2007-03-01

    Full Text Available Abstract Background Finding over- or under-represented motifs in biological sequences is now a common task in genomics. Thanks to p-value calculation for motif counts, exceptional motifs are identified and represent candidate functional motifs. The present work addresses the related question of comparing the exceptionality of one motif in two different sequences. Just comparing the motif count p-values in each sequence is indeed not sufficient to decide if this motif is significantly more exceptional in one sequence compared to the other one. A statistical test is required. Results We develop and analyze two statistical tests, an exact binomial one and an asymptotic likelihood ratio test, to decide whether the exceptionality of a given motif is equivalent or significantly different in two sequences of interest. For that purpose, motif occurrences are modeled by Poisson processes, with a special care for overlapping motifs. Both tests can take the sequence compositions into account. As an illustration, we compare the octamer exceptionalities in the Escherichia coli K-12 backbone versus variable strain-specific loops. Conclusion The exact binomial test is particularly adapted for small counts. For large counts, we advise to use the likelihood ratio test which is asymptotic but strongly correlated with the exact binomial test and very simple to use.

  16. Scintillators

    International Nuclear Information System (INIS)

    Cusano, D.A.; Holub, F.F.; Prochazka, S.

    1979-01-01

    Scintillator bodies comprising phosphor materials and having high optical translucency with low light absorption, and methods of making the scintillator bodies, are described. Fabrication methods include (a) a hot-pressing process, (b) cold-pressing followed by sintering, (c) controlled cooling from a melt, and (d) hot-forging. The scintillator bodies that result are easily machined to desired shapes and sizes. Suitable phosphors include BaFCl:Eu, LaOBr:Tb, CsI:Tl, CaWO 4 and CdWO 4 . (U.K.)

  17. Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Deyglun, C.; Simony, B.; Perot, B.; Carasco, C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); Saurel, N.; Colas, S. [CEA, DAM, Valduc, F-21120 Is-sur-Tille (France); Collot, J. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Grenoble Alpes, CNRS/IN2P3, Grenoble (France)

    2015-07-01

    The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a

  18. QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting

    International Nuclear Information System (INIS)

    Cassette, Philippe

    2016-01-01

    In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ"2 minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. - Highlights: • The program “QUENCH” is devoted to the interpolation of quenching curves in LSC. • Functions are fitted to experimental data with uncertainties in both quenching and efficiency. • The parameters of the fitting function and the associated covariance matrix are evaluated. • The detection efficiency and uncertainty corresponding to a given quenching index is calculated.

  19. Spectrum library concept and pulse shape analysis in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Kaihola, L [Wallac Oy, Turku (Finland)

    1997-03-01

    Wallac introduced in 1990 a new absolute liquid scintillation counting (LSC) method, Digital Overlay Technique (DOT) to correct for quench. This method allows quantization of multilabel samples by referring to library spectra which are generated against chemical and color quench indices at the factory. The libraries can further be expanded to any beta emitter by user with a method called fine tuning, which can be carried out even with a single sample. Spectrum libraries are created over the whole spectrum range of the radionuclide and allow automatic identification of a single label beta emitting radionuclide, called Easy Count method. Another improvement in LSC is commercial introduction of Pulse Shape Analysis (PSA) in 1986 by Wallac. This method recognizes alpha particle decay by pulse shape and leads to excellent sensitivity in alpha counting because most of the background signal in LSC comprises of short or beta like pulses. PSA detects alpha events in the presence of high excess of beta activity over alphas, up to a ratio 100000 to 1. (orig.)

  20. Gross alpha and gross beta determination in surface and groundwater water by liquid scintillation counting (LSC)

    International Nuclear Information System (INIS)

    Faria, Ligia S.; Moreira, Rubens M.

    2013-01-01

    The present study has used 40 samples of groundwater and surface water collected at four different sites along the period of one year in Brumadinho and Nova Lima, two municipalities in the State of Minas Gerais, Brazil, as part of a more extensive study aiming at determination of the natural radioactivity in the water used for domestic use. These two sites are inside an Environmental Protection Area is located in a region of very intensive iron ore exploration. In addition of mineral resources, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium. Radioactivity levels were determined via liquid scintillation counting (LSC), a fast and high counting efficiency method that can be advantageously employed to determine gross alpha and gross beta activity in liquid samples. Previously to gross alpha and gross beta counting the samples were acidified with concentrated HNO 3 in the field. The technique involved a pre-concentration of the sample to obtain a low detection limit. Specific details of the employed methodology are commented. The results showed that concentrations of gross alpha natural activity and gross beta values ranged from less than the detection limit of the equipment (0.03 Bq.L -1 ) to 0.275 ± 0.05 Bq.L -1 for gross alpha. As regards gross beta, all samples were below the limit of detection. (author)

  1. Determination of 226Ra and 224Ra in sediments samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Villa, M.; Moreno, H.P.; Manjon, G.

    2005-01-01

    An experimental procedure has been developed for a rapid determination of the activity concentration of 226 Ra and 224 Ra in sediments by liquid scintillation counting. The importance of the method lies in its application to the measurement of sediments where the Ra-isotopes activity concentration has been increased due to an anthropomorphic enhancement based on releases of naturally occurring radioactive material (NORM). A sample pre-treatment, including a digestion with aqua regia and a precipitation of hydroxides, was applied to samples before the radium extraction, which was made by co-precipitation with barium. Measurements were done in a low background scintillation spectrometer Quantulus 1220, which can separate and detect simultaneously α and β particles. Additionally, some improvements are suggested for a better α and β interference correction of the results. The obtaining of radiochemical yields is also improved using 133 Ba as tracer, which decays by emission of conversion electrons and γ-rays; the wide range of radiochemical yields obtained confirms the need of this analyses. The procedure has been applied to the measurement of riverbed sediments from an estuary in the south-west of Spain, affected in the past by direct and indirect phosphogypsum discharges

  2. Variable sampling-time technique for improving count rate performance of scintillation detectors

    International Nuclear Information System (INIS)

    Tanaka, E.; Nohara, N.; Murayama, H.

    1979-01-01

    A new technique is presented to improve the count rate capability of a scintillation spectrometer or a position sensitive detector with minimum loss of resolution. The technique is based on the combination of pulse shortening and selective integration in which the integration period is not fixed but shortened by the arrival of the following pulse. Theoretical analysis of the degradation of the statiscal component of resolution is made for the proposed system with delay line pulse shortening, and the factor of resolution loss is formulated as a function of the input pulse rate. A new method is also presented for determining the statistical component of resolution separately from the non-statistical system resolution. Preliminary experiments with a NaI(Tl) detector have been carried out, the results of which are consistent with the theoretical prediction. However, due to the non-exponential scintillation decay of the NaI(Tl) crystal, a simple delay line clipping is not satisfactory, and an RC high-pass filter has been added, which results in further degradation of the statistical resolution. (Auth.)

  3. Usage of liquid scintillation counting for detecting the chemiluminescence of cells and its application in medicine

    International Nuclear Information System (INIS)

    Li Tianxing; Liang Qizhong; Zou Xiaowei; Yang Zhaohen; Huang Yong; Li Huaqiang

    1995-01-01

    The liquid scintillator counting-chemiluminescence (LSC-CL) of mono-photon radiance is a sensitive, handy and high-autoanalytic technique. Through measuring basic CL, dependent CL and maximum phagocytic CL of polymorphonuclear (PMN), we studied best factor levels of the method with orthogonal design [L 9 (3 4 )]. The results showed the peak forms changed markedly (inter-group P -4 M). PMN-CL in blood was measured during acute attack of the old patients with chronic bronchitis and the children with pneumonia bronchial. It was suggested that PMN phagocytosis decreased. So the dynamic analysis of maximum phagocytic CL would help us with the deep going clinical researches of the mechanisms of anti-inflammation and injuring by the oxygen free radicals

  4. Liquid scintillation counting of calcium-45 in plant and soil material

    International Nuclear Information System (INIS)

    Waller, S.S.; Dodd, J.D.

    1977-01-01

    The recovery efficiencies of 45 Ca, for plant material using dry ashing with HCL as the extractant, and for soils using column extraction with MgCl 2 as the extractant, have been determined. The extraction and detection procedures, using available scintillation solvent systems, are given and show a combination of a high counting efficiency with high recovery efficiencies. The extraction procedures are simple, involving minimal operator time, and allow simultaneous 45 Ca determination in both plant and soil material. Both extraction procedures exhibit good reproducibility over a wide range of specific activities while being relatively insensitive to quenching and carrier calcium normally encountered in plant and soil material. These procedures are particularly useful in ecological studies requiring the examination of a large number of plant and/or soil samples over a wide range of radioactive concentrations. (U.K.)

  5. A methodology for the optimization of the estimation of tritium in urine by liquid scintillation counting

    International Nuclear Information System (INIS)

    Joseph, S.; Kramer, G.H.

    1982-10-01

    A method has been designed to optimize liquid scintillation (LS) urinalysis with respect to sensitivity and cost. Three related factors, quench, sample composition and counting efficiency, were measured simultaneously and the results plotted in three dimensions to determine the optimum conditions for urinalysis. Picric acid was used to simulate quenching. Subsequent urinalysis experiments showed that quenching by picric acid was analogous to urine quenching. The optimization methodology was applied to ten commercial LS cocktails and a wide divergence in results was obtained. This method can also be used to optimize minimum detectable activities (MDA) but the results show that there is no fixed sample composition that can be used for all the various types of urine samples; however, it is possible to achieve general improvements of at least a factor of 2 in the MDA for Scintiverse (the only one tested for this particular application of the methodology)

  6. Alternating sample changer and an automatic sample changer for liquid scintillation counting of alpha-emitting materials

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1977-08-01

    Two sample changers are described that were designed for liquid scintillation counting of alpha-emitting samples prepared using solvent-extraction chemistry. One operates manually but changes samples without exposing the photomultiplier tube to light, allowing the high voltage to remain on for improved stability. The other is capable of automatically counting up to 39 samples. An electronic control for the automatic sample changer is also described

  7. The measurement of Rn-222 in drinking water by low-level liquid scintillation counting

    International Nuclear Information System (INIS)

    Barnett, J.M.; McKlveen, J.W.

    1991-01-01

    Radon-222 has consistently been found in well water. The research objectives are to establish a method to collect well water and to measure the Rn in ground water using liquid scintillation (LS) counting. Water is collected at the well head while the well is pumping. The water is adjusted to a slow, non-aerated, steady flow through a clear tube, and a 437 mL (16 oz) glass bottle is filled. The sample is tightly capped after a high meniscus has developed. In the laboratory, standard 22 mL LS glass vials are filled with 10 mL of a toluene based mineral oil LS cocktail. Then, two 5 mL sample aliquots are pipetted into the vial. Vials are capped tightly, shaken vigorously, and placed in the LS counter. Secular equilibrium is established in approximately 3.5 hours, after which samples are counted for 100 minutes each. Quality assurance and control is performed weekly on the LS counter's electronics, spectral window, counting efficiency, and background. The counting efficiency ranges between 315-345 percent depending on the chosen spectral window. The average background is about 6 cpm. A total of 28 wells were tested for Rn in the Carefree-Cave Creek, Arizona, USA area, and 12 wells were selected, each over 50 Bq/L (1,350 pCi/L), for an extended 6 month period. The area's average Rn concentration was found to be 46.5 Bq/L (1,255 pCi/L); it is a geometric mean. The associated estimated lung dose is 1.13 mSv/a

  8. Precise method for correcting count-rate losses in scintillation cameras

    International Nuclear Information System (INIS)

    Madsen, M.T.; Nickles, R.J.

    1986-01-01

    Quantitative studies performed with scintillation detectors often require corrections for lost data because of the finite resolving time of the detector. Methods that monitor losses by means of a reference source or pulser have unacceptably large statistical fluctuations associated with their correction factors. Analytic methods that model the detector as a paralyzable system require an accurate estimate of the system resolving time. Because the apparent resolving time depends on many variables, including the window setting, source distribution, and the amount of scattering material, significant errors can be introduced by relying on a resolving time obtained from phantom measurements. These problems can be overcome by curve-fitting the data from a reference source to a paralyzable model in which the true total count rate in the selected window is estimated from the observed total rate. The resolving time becomes a free parameter in this method which is optimized to provide the best fit to the observed reference data. The fitted curve has the inherent accuracy of the reference source method with the precision associated with the observed total image count rate. Correction factors can be simply calculated from the ratio of the true reference source rate and the fitted curve. As a result, the statistical uncertainty of the data corrected by this method is not significantly increased

  9. The measurement of 222Rn in drinking water by low-level liquid scintillation counting

    International Nuclear Information System (INIS)

    Barnett, J.M.; McKlveen, J.W.

    1992-01-01

    Radon-222 (Rn) has universally been found in well water. Non-stagnant ground water is collected at the well head while the well is pumping. The water is adjusted to a slow, non-aerated, steady flow through a clear tube, and a 500 ml glass bottle is filled. The sample is tightly capped after a high meniscus has developed. In the laboratory, standard 22 ml glass vials are filled with 10 ml of a toluene based mineral oil LS cocktail. Then, two 5 ml sample aliquots are pipetted into the vial. Vials are capped tightly, shaken vigorously, and placed in the liquid scintillation (LS) counter. Secular equilibrium is established in approximately 4 hours, after which samples are counted for 100 minutes each. The counting efficiency for Rn and progeny ranges between 315 to 345 percent depending on the chosen spectral window. The average background is about 6 cpm. A total of 28 wells were tested for Rn in the Carefree-Cave Creek, Arizone, USA area. The area's geometric average Rn concentration was found to be 46.5 Bq*1 -1 . The associated estimated lung dose is 0.51 mSv*y -1 . (author) 8 refs.; 1 fig.; 1 tab

  10. Resolving time of scintillation camera-computer system and methods of correction for counting loss, 2

    International Nuclear Information System (INIS)

    Iinuma, Takeshi; Fukuhisa, Kenjiro; Matsumoto, Toru

    1975-01-01

    Following the previous work, counting-rate performance of camera-computer systems was investigated for two modes of data acquisition. The first was the ''LIST'' mode in which image data and timing signals were sequentially stored on magnetic disk or tape via a buffer memory. The second was the ''HISTOGRAM'' mode in which image data were stored in a core memory as digital images and then the images were transfered to magnetic disk or tape by the signal of frame timing. Firstly, the counting-rates stored in the buffer memory was measured as a function of display event-rates of the scintillation camera for the two modes. For both modes, stored counting-rated (M) were expressed by the following formula: M=N(1-Ntau) where N was the display event-rates of the camera and tau was the resolving time including analog-to-digital conversion time and memory cycle time. The resolving time for each mode may have been different, but it was about 10 μsec for both modes in our computer system (TOSBAC 3400 model 31). Secondly, the date transfer speed from the buffer memory to the external memory such as magnetic disk or tape was considered for the two modes. For the ''LIST'' mode, the maximum value of stored counting-rates from the camera was expressed in terms of size of the buffer memory, access time and data transfer-rate of the external memory. For the ''HISTOGRAM'' mode, the minimum time of the frame was determined by size of the buffer memory, access time and transfer rate of the external memory. In our system, the maximum value of stored counting-rates were about 17,000 counts/sec. with the buffer size of 2,000 words, and minimum frame time was about 130 msec. with the buffer size of 1024 words. These values agree well with the calculated ones. From the author's present analysis, design of the camera-computer system becomes possible for quantitative dynamic imaging and future improvements are suggested. (author)

  11. Digital liquid-scintillation counting and effective pulse-shape discrimination with artificial neural networks

    International Nuclear Information System (INIS)

    Langrock, Gert; Wiehl, Norbert; Kling, Hans-Otto; Mendel, Matthias; Naehler, Andrea; Tharun, Udo; Eberhardt, Klaus; Trautmann, Norbert; Kratz, Jens Volker

    2015-01-01

    A typical problem in low-level liquid scintillation (LS) counting is the identification of α particles in the presence of a high background of β and γ particles. Especially the occurrence of β-β and β-γ pile-ups may prevent the unambiguous identification of an α signal by commonly used analog electronics. In this case, pulse-shape discrimination (PSD) and pile-up rejection (PUR) units show an insufficient performance. This problem was also observed in own earlier experiments on the chemical behaviour of transactinide elements using the liquid-liquid extraction system SISAK in combination with LS counting. α-particle signals from the decay of the transactinides could not be unambiguously assigned. However, the availability of instruments for the digital recording of LS pulses changes the situation and provides possibilities for new approaches in the treatment of LS pulse shapes. In a SISAK experiment performed at PSI, Villigen, a fast transient recorder, a PC card with oscilloscope characteristics and a sampling rate of 1 giga samples s -1 (1 ns per point), was used for the first time to record LS signals. It turned out, that the recorded signals were predominantly α β-β and β-γ pile up, and fission events. This paper describes the subsequent development and use of artificial neural networks (ANN) based on the method of 'back-propagation of errors' to automatically distinguish between different pulse shapes. Such networks can 'learn' pulse shapes and classify hitherto unknown pulses correctly after a learning period. The results show that ANN in combination with fast digital recording of pulse shapes can be a powerful tool in LS spectrometry even at high background count rates.

  12. Digital liquid-scintillation counting and effective pulse-shape discrimination with artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Langrock, Gert; Wiehl, Norbert; Kling, Hans-Otto; Mendel, Matthias; Naehler, Andrea; Tharun, Udo; Eberhardt, Klaus; Trautmann, Norbert; Kratz, Jens Volker [Mainz Univ. (Germany). Inst. fuer Kernchemie; Omtvedt, Jon-Petter [Oslo Univ. (Norway). Dept. of Chemistry; Skarnemark, Gunnar [Chalmers Univ. of Technology, Goeteborg (Sweden)

    2015-05-01

    A typical problem in low-level liquid scintillation (LS) counting is the identification of α particles in the presence of a high background of β and γ particles. Especially the occurrence of β-β and β-γ pile-ups may prevent the unambiguous identification of an α signal by commonly used analog electronics. In this case, pulse-shape discrimination (PSD) and pile-up rejection (PUR) units show an insufficient performance. This problem was also observed in own earlier experiments on the chemical behaviour of transactinide elements using the liquid-liquid extraction system SISAK in combination with LS counting. α-particle signals from the decay of the transactinides could not be unambiguously assigned. However, the availability of instruments for the digital recording of LS pulses changes the situation and provides possibilities for new approaches in the treatment of LS pulse shapes. In a SISAK experiment performed at PSI, Villigen, a fast transient recorder, a PC card with oscilloscope characteristics and a sampling rate of 1 giga samples s{sup -1} (1 ns per point), was used for the first time to record LS signals. It turned out, that the recorded signals were predominantly α β-β and β-γ pile up, and fission events. This paper describes the subsequent development and use of artificial neural networks (ANN) based on the method of 'back-propagation of errors' to automatically distinguish between different pulse shapes. Such networks can 'learn' pulse shapes and classify hitherto unknown pulses correctly after a learning period. The results show that ANN in combination with fast digital recording of pulse shapes can be a powerful tool in LS spectrometry even at high background count rates.

  13. Apparent and actual 14C retention in the slower turnover bicarbonate pool in man when using liquid scintillation counting

    International Nuclear Information System (INIS)

    Clague, M.B.; Keir, M.J.; Clayton, C.B.

    1979-01-01

    The use of liquid scintillation counting to determine 14 CO 2 expiration without correct calibration of the apparatus suggests that about 25% of the label is retained within the slower turnover bicarbonate pool. Calibration reduces this figure to 13% and is in agreement with the figure obtained using a calibrated ionisation chamber. The discrepancy is due to reduction in the specific radioactivity in the vial, the mechanism involved being unknown, but it may be a characteristic of certain liquid scintillators under certain conditions. (author)

  14. A comparative study of 19-iodocholesterol-''125I 3-acetate and Na''125I in liquid scintillation measurements

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    A comparative study of performance of 19-iodocholesterol-''125I 3-acetate and sodium iodine samples labelled with ''125 I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I''-concentration of 0-90 ug and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol-''125I 3-acetate samples in Toluene-alcohol and 0.04% for Na''125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs

  15. A comparative study of 19-iodo cholesterol-125I 3-acetate and Na 125I in liquid scintillation measurements

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-01-01

    A comparative study of performance of 19-iodo cholesterol 1 25I 3-acetate and sodium iodide samples labeled with 125I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I concentration of 0-90 μg and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol 1 I 3-acetate samples in Tolue ne-alcohol and 0 .04% for Na 125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs

  16. Comparison of image uniformity with photon counting and conventional scintillation single-photon emission computed tomography system: A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Chul; Lee, Young Jin [Dept. of Radiological Science, Eulji University, Seongnam (Korea, Republic of); Kim, Hee Joung; Kim, Kyuseok; Lee, Min Hee [Yonsei University, Wonju (Korea, Republic of)

    2017-06-15

    To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a {sup 99m}Tc gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

  17. Ionic liquids as solvents for liquid scintillation technology. Čerenkov counting with 1-Butyl-3-Methylimidazolium Chloride

    International Nuclear Information System (INIS)

    Mirenda, Martín; Rodrigues, Darío; Arenillas, Pablo; Gutkowski, Karin

    2014-01-01

    We report the detection of the Čerenkov luminescence after the incorporation of a few droplets of a physiological solution of 2-deoxi-2( 18 F)fluorine-D-glucose into the ionic liquid 1-Butyl-3-Methylimidazolium Chloride (BmimCl). The phenomenon is attributed to the β + particles having energy above the threshold energy value for the Čerenkov radiation in this medium. The presence of another type of radiation that could eventually cause coincidences in the photodetectors was safely discarded. We show that this property serves to determine the activity of a 18 F solution by means of the novel TDCR–Čerenkov technique. The results were compared with those obtained from the classic TDCR scintillation method using a commercial scintillation cocktail. The activity values obtained from both methods were found to be virtually identical within the experimental uncertainties. The fact that high energy β particles in BmimCl generates Čerenkov photons makes this ionic liquid a promising compound for future research in detection and quantification of ionizing radiation, and it provides a potential alternative for applications in nuclear technology. - Highlights: • Čerenkov luminescence was detected when 18 F was dissolved in 1-Butyl-3-Methylimidazolium Chloride (BmimCl) ionic liquid. • The presence of another type of radiation that could eventually cause coincidences in the photodetectors was safely discarded. • Čerenkov luminescence serves to determine the activity of a 18 F solution by means of TDCR–Čerenkov technique. • Some advantages of the use of BmimCl as solvent for Čerenkov counting were listed

  18. Review of the evolution of safety, ecological and economical aspects of liquid scintillation counting materials and techniques

    International Nuclear Information System (INIS)

    Kalbhen, D.A.

    1983-01-01

    The wide applicability of liquid scintillation techniques for counting weak β-emitters and other radionuclides has led to the daily use of a large number of liquid scintillation counter instruments in research and control laboratories. Of the solvents used in liquid scintillators, xylene, toluene and trimethyl benzene are most common. To a minor extent, dioxane, methylglycol, ethanol and methanol are also used. The estimated annual total volume is around 2-3 million liters of scintillation cocktails. The present situation demonstrates a problem in laboratory safety and concomitant cost for waste treatment, usually not recognized. The use and handling of these inflammable and irritant solvents can induce certain risks to personnel and laboratory safety. A significant reduction of the ecological and health risks is important. In recent years, some progress has been made by using smaller volumes and smaller sizes of vials. The introduction of non-flammable scintillator solvents, which do not penetrate through polyethylene vials and do not escape into the laboratory atmosphere, also adds to the safety process

  19. The Comparative Accuracy of the 4 {pi} Liquid Scintillation Counting Method of Radioisotope Standardization; L'exactitude comparee de la methode de comptage 4 {pi} a scintillateurs liquides pour l'etalonnage des radioisotopes; Sravnitel'naya tochnost' 4 {pi} zhidkogo stsintillatsionnogo metoda podscheta standartiziruemykh radioizotopov; Exactitud del metodo de recuento con centelleador liquido 4 {pi} para normalizar radioisotopos, comparada con la de otros metodos

    Energy Technology Data Exchange (ETDEWEB)

    Steyn, J [National Physical Research Laboratory, Pretoria (South Africa)

    1960-06-15

    The accuracy of the 4 {pi} liquid scintillation counting method of standardizing {beta} emitters was compared to 4 l{pi} {beta}-{gamma} coincidence counting for the nuclides Co{sup 60}, I{sup 131} and Au{sup 198}. For P{sup 32} the liquid counting results were compared to 4 {pi} proportional counting. The efficiency of the liquid scintillation counting method was found to be energy dependent, dropping to about 97.5% for Co{sup 60} which was the lowest energy {beta} emitter investigated. (author) [French] La precision de la methode de comptage 4 {pi} a scintillateurs liquides pour l'etalonnage des emetteurs {beta} a ete comparee au comptage par coincidences 4 {pi} {beta}-{gamma} pour le So{sup 60}, le I{sup 131} et le Au{sup 198}. Dans le cas du P{sup 32}, les resultats du comptage au liquide ont ete compares a ceux du comptage 4 {pi} proportionnel. On a constate que le rendement de la methode de comptage a scintillateurs liquides variait en fonction de l'energie emise et qu'il descendait a environ 97.5% pour le Co{sup 60} qui, de tous les emetteurs {beta} etudies, emet l'energie la plus faible. (author) [Spanish] El autor compara la precision del metodo de recuento con centelleador iquido 4 {pi} para normalizar emisores {beta} con la del metodo de coincidencias {beta}-{gamma} 4 {pi}, para los siguientes nuclidos: So{sup 60}, I{sup 131} y Au{sup 198}. En el caso del P{sup 32}, confronta los resultados del primer metodo con los obtenidos mediante el recuento proporcional 4 {pi}. Comprueba que la eficacia del metodo de recuento con centelleador liquido depende de la energia y desciende al 97.5%, aproximadamente, para el Co{sup 60}, que fue el emisor {beta} mas debil que se investigo. (author) [Russian] Tochnost' 4 {pi} zhidkogo stsintillyatsionnog o metoda podscheta standartiziruemogo {beta}-izluchatelya sravnivalas' s 4 {pi} {beta}-{gamma} metodom podscheta na sovpadeniyakh dlya izotopov So{sup 60}, I{sup 131} i Au{sup 198}. Dlya R{sup 32} rezultaty zhidkogo

  20. Rapid radiometric detection of microbial contamination using 14C-glucose and standard liquid scintillation counting system

    International Nuclear Information System (INIS)

    Joshi, S.H.; Kamble, S.B.; Pilkhwal, N.S.; Ramamoorthy, N.

    1998-01-01

    A simple and rapid method for detection of microbial contamination based on quantitation of 14 CO 2 released during metabolism of 14 C-Glucose by microorganisms is reported. Liquid scintillation counting system (LSCS) with a modified sample preparation method was utilised. The scintillator was impregnated on Whatman-1 paper on which 14 CO 2 evolved during metabolism could be absorbed. The important parameters of counting such as efficiency, position sensitivity and geometry as well as effect of NaOH quantity and of microbial load on detection period were studied. The efficiency of radioactivity assay was 18±2.8 %. Contamination of the order of 5-10 organism/ml of product could be detected in about 24 hours. (author)

  1. Comparison of triple to double coincidence ratio and Quench Parameter External methods for the determination of 3H efficiency by liquid scintillation counting

    International Nuclear Information System (INIS)

    Nisti, M.B.; Saueia, C.H.R.; Mazzilli, B.P.

    2013-01-01

    The aim of this study is to determine the tritium efficiency by liquid scintillation counting using two methodologies, Quench Parameter External (QPE) and Triple to Double Coincidence Ratio (TDCR), and to compare the results. The equipment used was the HIDEX model 300-SL Liquid Scintillation Counter, composed of three photomultipliers coupled with coincidence pulses, discrimination level and Mikro Win 2000 software. The efficiency varied from 0.028 to 0.706 cps dps -1 for QPE and from 0.061 to 0.703 cps dps -1 for TDCR. Different efficiencies were obtained using both methods, in the range from 459 to 572 quenching, above this range the efficiencies were similar. The verification of the efficiencies was performed by participating in the Intercomparison National Program (PNI). (author)

  2. Chemical and colour quenching in liquid scintillation counting; Estudio de la extincion quimica y por color en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Scott, P E; Grau, A

    1987-07-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs.

  3. Rapid determination of gross alpha and beta activity in seafood utilizing microwave digestion and liquid scintillation counting

    International Nuclear Information System (INIS)

    Daniel Sas; Jiri Janda; Alena Tokarova

    2015-01-01

    This paper describes a method for rapid determination of gross alpha and beta activity in seafood using liquid scintillation counting and microwave digestion for fast sample decomposition. The general group of seafood was divided into two groups based on its structure, whether it has shell or not. The selected group of radionuclides was chosen with respect to military significance, radiotoxicity, and possibility of potential misuse. 90 Sr and 239 Pu were selected as model radionuclides. (author)

  4. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1985-07-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3{sup H} and the polynomial or tabulated relating counting efficiency as figure of merit for both 3{sup H} and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14{sup C}. The results of four different computation methods are compared. (Author) 17 refs.

  5. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1985-01-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3 H and the polynomial or tabulated relating counting efficiency as figure of merit for both 3 H and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14 C . The results of four different computation methods are compared. (Author) 17 refs

  6. Activity measurements of radioactive solutions by liquid scintillation counting and pressurized ionization chambers and Monte Carlo simulations of source-detector systems for metrology

    International Nuclear Information System (INIS)

    Amiot, Marie-Noelle

    2013-01-01

    The research works 'Activity measurements of radioactive solutions by liquid scintillation and pressurized ionization chambers and Monte Carlo simulations of source-detector systems' was presented for the graduation: 'Habilitation a diriger des recherches'. The common thread of both themes liquid scintillation counting and pressurized ionization chambers lies in the improvement of the techniques of radionuclide activity measurement. Metrology of ionization radiation intervenes in numerous domains, in the research, in the industry including the environment and the health, which are subjects of constant concern for the world population these last years. In this big variety of applications answers a large number of radionuclides of diverse disintegration scheme and under varied physical forms. The presented works realized within the National Laboratory Henri Becquerel have for objective to assure detector calibration traceability and to improve the methods of activity measurements within the framework of research projects and development. The improvement of the primary and secondary activity measurement methods consists in perfecting the accuracy of the measurements in particular by a better knowledge of the parameters influencing the detector yield. The works of development dealing with liquid scintillation counting concern mainly the study of the response of liquid scintillators to low energy electrons as well as their linear absorption coefficients using synchrotron radiation. The research works on pressurized ionization chambers consist of the study of their response to photons and electrons by experimental measurements compared to the simulation of the source-detector system using Monte Carlo codes. Besides, the design of a new type of ionization chamber with variable pressure is presented. This new project was developed to guarantee the precision of the amount of activity injected into the patient within the framework of diagnosis examination

  7. Preparation of manganese salts of carboxylic acids labelled with ''54Mn and comparison with ''54 MnCl2 in liquid scintillation counting

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Arcos Merino, J. M. los; Grau Malonda, A.

    1992-01-01

    Procedures for liquid scintillation sample preparation of manganese dimethylbutirate, decanoate and palmitate, labelled with 54 Mn are described. their quenching effect, spectral evolution and counting stability along several weeks are analysed in liquid scintillation measurements with Toluene. HISafe II. PCS, instagel. Dioxane-naphtalene and Toluene-alcohol. For comparison, Inorganic 54 MnCl-2 samples are also studied, resulting in acceptable counting stability but showing greater quenching and signs of little spectral degradation against the organic samples. (Author)

  8. {sup 226}Ra, {sup 228}Ra and {sup 210}Pb determination in surface water and groundwater by liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Ligia S.; Moreira, Rubens M., E-mail: ligsfaria@gmail.com, E-mail: rubens@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    The municipalities of Brumadinho and Nova Lima are located in the metropolitan region of Belo Horizonte city, in the State of Minas Gerais. These two sites are important due to being located inside an Environmental Protection Area inserted in the Iron Quadrangle. In addition to the mineral wealth, the region has geological features that include quartz conglomerates associated with uranium and a significant groundwater potential exhibiting quite peculiar and complex hydrogeological features, such as the quartzite aquifer itself. Nuclear techniques applied to hydrology, such as Liquid Scintillation Counting technique (LSC), make possible the evaluation of natural radioactivity in surface water and groundwater. The objectives of this study were the determination of the activities of the long half-life radionuclides of the uranium and thorium series, such as {sup 226}Ra, {sup 228}Ra and {sup 210}Pb, and provide an effective methodology to define if the direct consumption of these waters can cause risk to health due to its radioactivity. The results were compared with the recommendations of the Ministry of Health. (author)

  9. Measurement of isotopic uranium in water for compliance monitoring by liquid scintillation counting with alpha/beta discrimination

    International Nuclear Information System (INIS)

    Venso, E.A.S.

    1993-01-01

    A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using α/β discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen. U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-ell aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi ell -1 . α-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi ell -1 are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain 234 U/ 238 U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation. The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross α activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi ell -1 , with seven samples exceeding the proposed Maximum Contaminant Level

  10. The study of error for analysis in dynamic image from the error of count rates in Nal (Tl) scintillation camera

    International Nuclear Information System (INIS)

    Oh, Joo Young; Kang, Chun Goo; Kim, Jung Yul; Oh, Ki Baek; Kim, Jae Sam; Park, Hoon Hee

    2013-01-01

    This study is aimed to evaluate the effect of T 1/2 upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with '9 9m TcO 4 - of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in χ 2 test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of T 1/2 error from change of gradient with -0.25% to +0.25%, if T 1/2 is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see T 1/2 error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a

  11. A simple method for calibration of Lucas scintillation cell counting system for measurement of 226Ra and 222Rn

    Directory of Open Access Journals (Sweden)

    N.K. Sethy

    2014-10-01

    Full Text Available Known quantity of radium from high grade ore solution was chemically separated and carefully kept inside the cavity of a Lucas Cell (LC. The 222Rn gradually builds up and attain secular equilibrium with its parent 226Ra. This gives a steady count after a suitable buildup period (>25 days. This secondary source was used to calibrate the radon counting system. The method is validated in by comparison with identical measurement with AlphaGuard Aquakit. The radon counting system was used to evaluate dissolved radon in ground water sample by gross alpha counting in LC. Radon counting system measures the collected radon after a delay of >180 min by gross alpha counting. Simultaneous measurement also carried out by AlphaGuard Aquakit in identical condition. AlphaGuard measures dissolved radon from water sample by constant aeration in a closed circuit without giving any delay. Both the methods are matching with a correlation coefficient of >0.9. This validates the calibration of Lucas scintillation cell counting system by designed encapsulated source. This study provides an alternative for calibration in absence of costly Radon source available in the market.

  12. MEASUREMENT OF RADIONUCLIDES USING ION CHROMATOGRAPHY AND FLOW-CELL SCINTILLATION COUNTING WITH PULSE SHAPE DISCRIMINATION

    International Nuclear Information System (INIS)

    Fjeld, R. A.; DeVol, T.A.; Leyba, J.D.

    2000-01-01

    Radiological characterization and monitoring is an important component of environmental management activities throughout the Department of Energy complex. Gamma-ray spectroscopy is the technology most often used for the detection of radionuclides. However, radionuclides which cannot easily be detected by gamma-ray spectroscopy, such as pure beta emitters and transuranics, pose special problems because their quantification generally requires labor intensive radiochemical separations procedures that are time consuming and impractical for field applications. This project focused on a technology for measuring transuranics and pure beta emitters relatively quickly and has the potential of being field deployable. The technology combines ion exchange liquid chromatography and on-line alpha/beta pulse shape discriminating scintillation counting to produce simultaneous alpha and beta chromatograms. The basic instrumentation upon which the project was based was purchased in the early 1990's. In its original commercial form, the instrumentation was capable of separating select activation/fission products in ionic forms from relatively pure aqueous samples. We subsequently developed the capability of separating and detecting actinides (thorium, uranium, neptunium, plutonium, americium, and curium) in less than 30 minutes (Reboul, 1993) and realized that the potential time savings over traditional radiochemical methods for isolating some of these radionuclides was significant. However, at that time, the technique had only been used for radionuclide concentrations that were considerably above environmental levels and for aqueous samples of relatively high chemical purity. For the technique to be useful in environmental applications, development work was needed in lowering detection limits; to be useful in applications involving non-aqueous matrices such as soils and sludges or complex aqueous matrices such as those encountered in waste samples, development work was needed in

  13. Determination of 63Ni and 55Fe in nuclear waste samples using radiochemical separation and liquid scintillation counting

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Frøsig Østergaard, L.; Nielsen, S.P.

    2005-01-01

    An analytical method for the determination of Ni-63 and Fe-55 in nuclear waste samples such as graphite, heavy concrete, aluminium and lead was developed. Different decomposition methods (i.e. ashing, acid digestion and alkali fusion) were investigated for the decomposition of the samples...... by extraction chromatography. The purified Ni-63 and Fe-55 was then measured by liquid scintillation counting. The chemical yields of the separation procedures for Fe-55 and Ni-63 are above 90% and the decontamination factors for all interfering radionuclides are more than 10(5). The detection limits...

  14. Chemical and colour quenching in liquid scintillation counting; Estudio de la extincion quimica y por color en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Scott, P. E.; Grau, A.

    1987-07-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs.

  15. Method for determination of radium-226 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-07-01

    The chemical procedure involves the isolation or radium from the sample solution by co-precipitation with lead sulphate. The precipitate is dissolved in alkaline DTPA. The radium isotopes are separated from other radionuclides by co-precipitation with barium sulphate. The barium/radium precipitate is dissolved in alkaline EDTA, the solution is transfered to a liquid scintillation vial and the organic scintillant is added. After sealing, the sample is left until equilibrium between Ra-226 and Rn-222 is established or until a suitable ingrowth time has elapsed. The alpha activity of Rn-222 and its short-lived daughters, Po-218 and Po-214, are measured by the use of a commercial liquid scintillation counter. By using the following procedure and a low level LSC a lover limit of detection of 2 mBq/sample can be achieved

  16. Counting efficiency for liquid scintillator systems with a single multiplier phototube; Eficiencia de recuento en espectrometros de centelleo con un solo fotomultiplicador

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1984-07-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs.

  17. Measurement of radon emanation of drainage layer media by liquid scintillation counting

    International Nuclear Information System (INIS)

    Turtiainen, T.

    2009-01-01

    Slab-on-ground is a typical base floor construction type in Finland. The drainage layer between the slab and soil is a layer of sand, gravel or crushed stone. This layer has a minimum thickness of 200 mm and is sometimes even 600 mm thick, and thus may be a significant contributor to indoor air radon. In order to investigate radon emanation from the drainage layer material, a simple laboratory test was developed. Many organic solvents have high Ostwald coefficients for radon, i.e., the ratio of the volume of gas absorbed to the volume of the absorbing liquid, which enables direct absorption of radon into a liquid scintillation cocktail. Here, we first present equations relating to the processes of gas transfer in emanation measurement by direct absorption into liquid scintillation cocktails. In order to optimize the method for emanation measurement, four liquid scintillation cocktails were assessed for their ability to absorb radon from air. A simple apparatus consisting of a closed glass container holding an open liquid scintillation vial was designed and the diffusion/absorption rate and Ostwald coefficient were determined for a selected cocktail. Finally, a simple test was developed based on this work. (author)

  18. A Procedure for the Rapid Determination of 226Ra and 228Ra in Drinking Water by Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, the environment programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Reliable, comparable and ‘fit for purpose’ results are essential requirements for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of such data. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available to both the analyst and the customer. This publication describes a procedure for the rapid determination of 226 Ra and 228 Ra in drinking water. The determination of radium in drinking water is important for protecting human health, since the consumption of drinking water containing radium may lead to an accumulation in the body, contributing to the radiological dose. The method is based on the separation of 226 Ra and 228 Ra from interfering elements using PbSO 4 and Ba(Ra)SO 4 coprecipitation steps. The isotopes 226 Ra and 228 Ra are then determined by liquid scintillation counting. The procedure is expected to be of general use to a wide range of laboratories, including the laboratories of the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network, both in emergency situations and for routine environmental monitoring purposes. The method was established after an extensive review of papers from the scientific literature, and was tested and validated in terms of repeatability and trueness (relative bias) in accordance with International Organization for Standardization guidelines. Reproducibility tests were performed at expert laboratories. The calculation of massic activities, uncertainty budget, decision threshold and detection limit are also described

  19. Water quality - Determination of tritium activity concentration - Liquid scintillation counting method (International Standard Publication ISO 9698:1989)

    International Nuclear Information System (INIS)

    Stefanik, J.

    1999-01-01

    This International Standard specifies a method for the determination of tritiated water ([ 3 H]H 2 O) activity concentration in water by liquid scintillation counting. The method is applicable to all types of water including seawater with tritium activity concentrations of up to 10 6 Bq/m 3 when using 20 ml counting vials. Below tritium activity concentrations of about 5 x 10 4 Bq/m 3[ 8], a prior enrichment step and/or the measurement of larger sample volumes can significantly improve the accuracy of the determination and lower the limit of detection. Tritium activity concentrations higher than 10 6 Bq/m 3 may be determined after appropriate dilution with distilled water of proven low tritium content. An alternative method for the determination of these higher activities involves increasing the tritium activity concentrations of the internal standard solution. The method is not applicable to the analysis of organically bound tritium; its determination requires an oxidative digestion

  20. The determination of Pu-241 by liquid scintillation counting in liquid effluents of the Karlsruhe Nuclear Research Center

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.; Pimpl, M.

    1983-04-01

    A procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption, the linear dependence of counting efficiency in the liquid scintillation counter from the resolution in the alpha spectrometer was used. Pu-238, Pu-239+240 and Pu-241 were measured in the liquid effluents of the Karlsruhe Nuclear Research Center (KfK). The concentrations in monthly mixed samples ranged from 0.07 until 46 nCi Pu-238/m 3 , from 0.13 until 2.1 nCi Pu-239+240/m 3 and from 25 until 190 nCi Pu-241/m 3 . Between 5.4% and 41% of the plutonium content of the KfK waste water are released to the River Old Rhine. The values for the activity ratio Pu-238/Pu-239+240 are between 0.39 and 1.1 and for Pu-241/Pu-239+240 are between 11 and 300. The mean value for Pu-241/Pu-239+240 is 61. The dose exposure of the environmental population of the Karlsruhe Nuclear Research Center caused by released Pu-241 is negligible low. (orig./HP) [de

  1. The determination of Pu-241 by liquid scintillation counting in gaseous effluents of an incineration facility, FERAB, and the Karlsruhe Nuclear Reprocessing Plant, WAK

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1983-03-01

    Although the concentration of Pu-241 in nuclear fuel to be reprocessed is high, there are only few results published about the emission of Pu-241 with gaseous and liquid effluents. Nearly no information is available, too, about the environmental contamination of nuclear installations by Pu-241. Therefore a procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption the linear dependence of counting efficiency in the liquid scintillation counter and the resolution in the α-spectrometer was used. (orig./HP) [de

  2. Preparatory on manganose salts of carboxilic acids labelled with 54Mn and comparison with 54MnCl2 in liquid scintillation counting

    International Nuclear Information System (INIS)

    Rodriguez, L.; Los Arcos, J.M.; Grau, A.

    1992-01-01

    Procedures for scintillation sample preparation of manganose dimethylbutirate, decanoate and palmitate, labelled with 54 Mn are described. Their quenching effect, spectral evolution and counting stability along several weeks are analysed in liquid scintillation measurements with Toluene, HlSafe II, PCS, Instagel, Dioxane-naphtalene and Toluene-alcohol. For comparison, inorganic 54 MnCl 2 samples are also studied, resulting in acceptable counting stability but showing greater quenching and signs of little spectral degradation against the organic samples. (author) 14 fig. 15 ref

  3. Liquid scintillation counting efficiency in three photomultiplier systems. Pure electron capture; Eficiencia de recuento por centelleo liquido en sistemas con tres fotomultiplicadores. Captura electronica pura

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos, J M; Grau Carles, A; Grau Malonda, A

    1990-07-01

    The tables of counting efficiency as a function of the figure of merit for a liquid scintillation counting system working with three phototubes are presented. The evaluation has been carried out for a Toluene-based scintillator with 5, 10 and 15 ml column, and 19 different radionuclides decaying by pure electron capture: 37Ar 41Ca, 49V, 53 Mn, 55Fe, 59Ni, 68Ge 7iGe, 82Sr, 97Tc, 118Te, 131CS, 137La, 140Ca, 157Tb, 165Er, 193Pt, 194Hg, 205Pb. (Author) 22 refs.

  4. System for whole body imaging and count profiling with a scintillation camera

    International Nuclear Information System (INIS)

    Kaplan, E.; Cooke, M.B.D.

    1976-01-01

    The present invention relates to a method of and apparatus for the radionuclide imaging of the whole body of a patient using an unmodified scintillation camera which permits a patient to be continuously moved under or over the stationary camera face along one axis at a time, parallel passes being made to increase the dimension of the other axis. The system includes a unique electrical circuit which makes it possible to digitally generate new matrix coordinates by summing the coordinates of a first fixed reference frame and the coordinates of a second moving reference frame. 19 claims, 7 figures

  5. Study on determination of 90Sr by liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Zhai Xiufang; Li Weiping; Tian Mei; Zou Ronghu

    2012-01-01

    Both of Liquid scintillation counting and Cerenkov counting can be used to determinate 90 Sr in samples by Liquid scintillation spectrometry. In this work, effects of scintillation vials wit-h different material, Liquid scintillation cocktails, sample volume, Strontium carrier, pH, quenching (chemical quenching and color quenching)are studied, and both counting methods are compared. For Liquid scintillation counting. The results show that the best appropriate volume ratio of sample and liquid scintillation cocktail is 8:12 for OPTIPHASE HISAFE-3 and OPTIPHASE HISAFE-2, stability of solution decreased when sample load exceeds the maximum load for both Liquid scintillation cocktails, and OPTIPHASE HISAFE-3 also show superior performance for high saline solution. The type of scintillation vial haven't clear influence on the MDA of 90 Sr. Chemical quenching and color quenching can decrease the counting efficiency. For Cerenkov counting, the lowest MDA is obtained when polyethylene plastic vial is used and sample volume is 20 ml. Color quenching decreases the counting efficiency, while there isn't chemical quenching for Cerenkov counting. The MDA of 90 Sr is 1.19 and 1.00 Bq/L for Liquid scintillation counting and Cerenkov counting with the optimal labeling condition. (authors)

  6. An improved method for 85Kr analysis by liquid scintillation counting and its application to atmospheric 85Kr determination

    International Nuclear Information System (INIS)

    Momoshima, Noriyuki; Inoue, Fumio; Sugihara, Shinji; Shimada, Jun; Taniguchi, Makoto

    2010-01-01

    Atmospheric 85 Kr concentration at Fukuoka, Japan was determined by an improved 85 Kr analytical method using liquid scintillation counting (LSC). An average value of 1.54 ± 0.05 Bq m -3 was observed in 2008, which is about two times that measured in 1981 at Fukuoka, indicating a 29 mBq y -1 rate of increase as an average for these 27 years. The analytical method developed involves collecting Kr from air using activated charcoal at liquid N 2 temperature and purifying it using He at dry ice temperature, followed by Kr separation by gas chromatography. An overall Kr recovery of 76.4 ± 8.1% was achieved when Kr was analyzed in 500-1000 l of air. The Kr isolated by gas chromatography was collected on silica gel in a quartz glass vial cooled to liquid N 2 temperature and the activity of 85 Kr was measured with a low-background LS counter. The detection limit of 85 Kr activity by the present analytical method is 0.0015 Bq at a 95% confidence level, including all propagation errors, which is equivalent with 85 Kr in 1.3 l of the present air under the analytical conditions of 72.1% counting efficiency, 0.1597 cps background count rate, and 76.4% Kr recovery.

  7. Method validation and verification in liquid scintillation counting using the long-term uncertainty method (LTUM) on two decades of proficiency test data

    International Nuclear Information System (INIS)

    Verrezen, F.; Vasile, M.; Loots, H.; Bruggeman, M.

    2017-01-01

    Results from proficiency tests gathered over the past two decades by the laboratory for low level radioactivity measurements for liquid scintillation counting of 3 H (184 results) and 14 C (74 results) are used to verify the validated measurement methods used by the laboratory, in particular the estimated uncertainty budget of the method and its reproducibility and stability. A linear regression approach is used for the analysis of the results, described in the literature as the long term uncertainty in measurement method. The present study clearly indicates the advantages of using proficiency test results in identifying possible constant or proportional bias effects as well as the possibility to compare the laboratory performance with the performance of peer laboratories. (author)

  8. Cosmic-muon intensity measurement and overburden estimation in a building at surface level and in an underground facility using two BC408 scintillation detectors coincidence counting system.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Liu, Chuanlei; Mailhot, Maverick

    2016-10-01

    A series of measurements have been recently conducted to determine the cosmic-muon intensities and attenuation factors at various indoor and underground locations for a gamma spectrometer. For this purpose, a digital coincidence spectrometer was developed by using two BC408 plastic scintillation detectors and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results indicate that the overburden in the building at surface level absorbs a large part of cosmic ray protons while attenuating the cosmic-muon intensity by 20-50%. The underground facility has the largest overburden of 39 m water equivalent, where the cosmic-muon intensity is reduced by a factor of 6. The study provides a cosmic-muon intensity measurement and overburden assessment, which are important parameters for analysing the background of an HPGe counting system, or for comparing the background of similar systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Measurement of 226Ra in water and 222Rn in water and air by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1992-01-01

    In the Austrian province of Lower Austria a comprehensive programme for measurement of 222 Rn and 226 Ra in drinking water was conducted. A simple liquid scintillation counting (LSC) method was used which gives a LLD of 30 mBq per litre for 226 Ra without any chemical separation. Results are presented and the health significance is discussed. For 222 Rn in air a commercially available simple charcoal system with LSC was used. The system was tested in a house with elevated radon concentration under normal living conditions. During relatively short 2-day periods a maximum deviation of ± 30% from the monthly mean value was found. The advantages of LSC are that the procedures are very simple and cheap. (author)

  10. Rapid determination of 226Ra in drinking water samples using dispersive liquid-liquid microextraction coupled with liquid scintillation counting

    International Nuclear Information System (INIS)

    Sadi, B.K.; Chunsheng Li; Kramer, G.H.; Johnson, C.L.; Queenie Ko; Lai, E.P.C.

    2011-01-01

    A new radioanalytical method was developed for rapid determination of 226 Ra in drinking water samples. The method is based on extraction and preconcentration of 226 Ra from a water sample to an organic solvent using a dispersive liquid-liquid microextraction (DLLME) technique followed by radiometric measurement using liquid scintillation counting. In DLLME for 226 Ra, a mixture of an organic extractant (toluene doped with dibenzo-21-crown-7 and 2-theonyltrifluoroacetone) and a disperser solvent (acetonitrile) is rapidly injected into the water sample resulting in the formation of an emulsion. Within the emulsion, 226 Ra reacts with dibenzo-21-crown-7 and 2-theonyltrifluoroacetone and partitions into the fine droplets of toluene. The water/toluene phases were separated by addition of acetonitrile as a de-emulsifier solvent. The toluene phase containing 226 Ra was then measured by liquid scintillation counting. Several parameters were studied to optimize the extraction efficiency of 226 Ra, including water immiscible organic solvent, disperser and de-emulsifier solvent type and their volume, chelating ligands for 226 Ra and their concentrations, inorganic salt additive and its concentration, and equilibrium pH. With the optimized DLLME conditions, the accuracy (expressed as relative bias, B r ) and method repeatability (expressed as relative precision, S B ) were determined by spiking 226 Ra at the maximum acceptable concentration level (0.5 Bq L -1 ) according to the Guidelines for Canadian Drinking Water Quality. Accuracy and repeatability were found to be less than -5% (B r ) and less than 6% (S B ), respectively, for both tap water and bottled natural spring water samples. The minimum detectable activity and sample turnaround time for determination of 226 Ra was 33 mBq L -1 and less than 3 h, respectively. The DLLME technique is selective for extraction of 226 Ra from its decay progenies. (author)

  11. Neutron detection and multiplicity counting using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array

    International Nuclear Information System (INIS)

    Miller, M.C.

    1998-03-01

    Neutron detection and multiplicity counting has been investigated using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array. Boron-loaded plastic combines neutron moderation (H) and detection ( 10 B) at the molecular level, thereby physically coupling increasing detection efficiency and decreasing die-away time with detector volume. Both of these characteristics address a fundamental limitation of thermal-neutron multiplicity counters, where 3 He proportional counters are embedded in a polyethylene matrix. Separation of the phoswich response into its plastic scintillator and bismuth germanate components was accomplished on a pulse-by-pulse basis using custom integrator and timing circuits. In addition, a custom time-tag module was used to provide a time for each detector event. Analysis of the combined energy and time event stream was performed by calibrating each detector's response and filtering based on the presence of a simultaneous energy deposition corresponding to the 10 B(n,alpha) reaction products in the plastic scintillator (93 keV ee ) and the accompanying neutron-capture gamma ray in the bismuth germanate (478 keV). Time-correlation analysis was subsequently performed on the filtered event stream to obtain shift-register-type singles and doubles count rates. Proof-of-principle measurements were conducted with a variety of gamma-ray and neutron sources including 137 Cs, 54 Mn, AmLi, and 252 Cf. Results of this study indicate that a neutron-capture probability of ∼10% and a die-away time of ∼10 micros are possible with a 4-detector array with a detector volume of 1600 cm 3 . Simulations were performed that indicate neutron-capture probabilities on the order of 50% and die-away times of less than 4 micros are realistically achievable. While further study will be required for practical application of such a detection system, the results obtained in this investigation are encouraging and may lead to a new class of high

  12. Development of nuclear counting system for plateau high voltage scintillation detector test facilities

    International Nuclear Information System (INIS)

    Sarizah Mohamed Nor; Siti Hawa Md Zain; Muhd Izham Ahmad; Izuhan Ismail

    2010-01-01

    Nuclear counter system is a system monitoring and analysis of radioactivity used in scientific and technical research and development in the Malaysian Nuclear Agency. It consists of three basic parts, namely sensors, signal conditioning and monitoring. Nuclear counter system set up for use in the testing of nuclear detectors using radioactive sources such as 60 Co and 137 Cs and other radioactive sources. It can determine the types of scintillation detectors and the equivalent function properly, always operate in the range plateau high voltage and meet the specifications. Hence, it should be implemented on all systems in the Nuclear Nuclear counter Malaysia and documented as Standard Working Procedure (SWP) is a reference to the technicians, trainees IPTA / IPTS and related workers. (author)

  13. Positron emission measurement with coincidence counting technic using large plastic scintillators

    International Nuclear Information System (INIS)

    Espinasse, P.; Minchella, P.

    1990-01-01

    For measuring positron emission of a large organ such as the brain for example, a device has been built with two cylindric plastic scintillators allowing the detection in coincidence of the 511 keV gamma rays without any spectrometry. The main results are for the sensitivity at the center of the field with 22 Na source in water: 240 ips/MBq; background = 12 ips, and for the countloss due to the deadtime >5% with 42 MBq. Sensitivity is almost uniform on the main axis between the probes. It falls to about 50% on the edges of a central diameter of 20 cm. The performances could certainly be improved by using modern rapid photomultipliers [fr

  14. 14C measurement: effect of variations in sample preparation and storage on the counting efficiency for 14C using a carbo-sorb/permafluor E+ liquid scintillation cocktail

    International Nuclear Information System (INIS)

    Kramer, S.J.; Milton, G.M.; Repta, C.J.W.

    1995-06-01

    The effect of variations in sample preparation and storage on the counting efficiency for 14 C using a Carbo-Sorb/PermafluorE+ liquid scintillation cocktail has been studied, and optimum conditions are recommended. (author). 2 refs., 2 tabs., 4 figs

  15. Free parameter, figure of merit and ionization quench in liquid scintillation counting

    International Nuclear Information System (INIS)

    Carles, P. Grau; Malonda, A. Grau

    2001-01-01

    A statistical study of the detection process demonstrates that the free parameter is essential to compute the counting efficiency in both CIEMAT/NIST and TDCR methods. An analysis of the computed counting efficiencies shows the uselessness of old definition of the figure of merit. A new definition is required and we adopt the idea of taking quantities related with the output of the photomultiplier. In addition, we justify the application of the chemical quenching simulation with the electronic variation of the photomultiplier gain. Finally, we describe a new procedure to determine the figure of merit and the optimum ionization-quenching factor from the pulse spectrum of different radionuclides. The robustness of the new procedure is tested with three different sets of stopping power for low-energy electrons

  16. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  17. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    International Nuclear Information System (INIS)

    Perez Sanchez, D.; Martin Sanchez, A.; Jurado Vargas, M.

    2003-01-01

    A simple radiochemical procedure has been developed to determine 210 Pb and 210 Po in environmental samples from the same matrix. Sediment samples are decomposed by leaching with mineral acids or by microwave digestion, while water samples are pre-concentrated. One part of the resulting solution, spiked with 209 Po, is used for 210 Po determination by spontaneous deposition onto nickel disks (a-spectrometry). The other part is assayed for 210 Pb, separating the Pb either by anion-exchange (sediment samples), or by solvent extraction (water samples). The 210 Pb source is finally prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The 210 Pb activity concentration is determined by liquid scintillation. A standard sediment sample supplied by IAEA and spiked water samples were analysed to check the procedure. The 210 Pb and 210 Po measurements agreed well with the certifications, deviations being less than 10%. The mean recoveries for Pb and Po were (70±12)% and (77±8)% for sediments, and (70±10)% and (81±7)% for waters, respectively. (author)

  18. Recent advances in low-level β-counting by liquid scintillation instrumentation

    International Nuclear Information System (INIS)

    Verzilov, Yu.; Maekawa, Fujio; Oyama, Yukio; Maekawa, Hiroshi

    1995-01-01

    This work attempts to solve problems for measurement 3 H and 32 P activity. A measurement of tritium activity in materials is desired for neutron experiments such as a fusion reactor blanket experiment and a neutron flux monitor with 6 Li(n,α) 3 H reaction. In such studies, lithium-containing pellets are usually irradiated by neutrons and the tritium produced in them is measured with a liquid scintillation counter. Tritium technique for Li 2 CO 3 is the subject of interest in the present study because this compound is well soluble and easy to use it. The 32 P is important nuclide in the in-system neutron spectrometry due to the following reactions: 31 P(n,γ) 32 P, 32 S(n,p) 32 P and 35 Cl(n,α) 32 P. For the reasons of similarity with Li 2 CO 3 , NH 4 PH 2 O 2 , CH 3 SO 2 CH 3 and NH 4 Cl were selected for measurement of 32 P activity. (J.P.N.)

  19. New procedure for the determination of radium in water by extraction of radon and application of integral counting with a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Horiuchi, K [Tokyo Metropolitan Univ. (Japan). Faculty of Science; Murakami, Y [Kitasato Univ. (Japan). School of Hygienic Sciences

    1981-05-01

    A new Ra determination method is devised, storing the sample in a glass bottle with a Teflon stopper in an upside-down position, extracting Rn with liquid scintillator solution and combining integral counting with a liquid scintillation counter. This method realizes a high sensitivity of 5 x 10/sup -13/ Ci Ra, eliminates the tedious procedure of transferring Rn through the vacuum system to the detector and makes possible repeated determinations of Ra on the same sample without any further chemical treatment except extraction.

  20. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    International Nuclear Information System (INIS)

    Sanchez, D.P.; Sanchez, A.M.; Vargas, M.J.

    2002-01-01

    A simple radiochemical procedure has been developed to determine 210 Pb and 210 Po in environmental samples. After adding 209 Po tracer and Pb carrier, an aliquot of the sample is decomposed by microwave digestion or by evaporation with mineral acids (depending on the expected activity of the sample). Part of the leaching solution must be used for 210 Po determination, preparing a polonium source by spontaneous deposition onto a nickel disk. The quantitative recoveries are determined using a standard 209 Po tracer, and the activity concentration is determined by isotopic dilution alpha spectrometry. The remaining part of the leaching solution is used for 210 Pb determination by means of two alternative methods: lead can be retained from 1.5 M HCl by the DOWEX 1 X 8, Cl - form resin in a chromatographic column, and stripped with deionised water, or it can be separated by solvent extraction as a lead bromide complex with the organic compound ALIQUAT-336 in toluene (this second method is used preferably in water samples). The Pb source for measurement is prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The activity concentration of 210 Pb is calculated from the spectra measured with a liquid scintillation spectrometer. Several certified material samples supplied by IAEA were analysed to check the procedure. The measured values for 210 Pb and 210 Po were in good agreement with the certified values presenting deviations lower than 5%. Several environmental samples (river and well waters and also sediments) from zones impacted by Uranium mine exploitation were analysed using the described procedure. The mean yields of Pb and Po were (70 ± 10)% and (81 ± 7)% for waters and (70 ± 12)% and (77 ± 8)% for sediments. (author)

  1. Internal Dosimetry Of I-131 For Radiation Workers Based On Analysis Of The Human Urine And Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    Nguyen Van Hung; Pham Hung Thai; Le Van Ngoc

    2011-01-01

    Internal dosimetry of I-131 for radiation workers based on analysis of the human urine, measuring radioactivity by the liquid scintillation system, and dose calculation by the specialized code has been firstly studied at the Nuclear Research Institute. Urine samples from the subjects internally contaminated with I-131 through respiratory ways were collected, chemically processed, measured beta radioactivities of I-131 by the liquid scintillation system of ALOKA-LSC-6100, and then thyroid doses and effective ones for whole-body were calculated by using the specialized code of LUDEP 2.0. Based on chemically separation procedure for I-131 in urine samples and the low background HPGe gamma spectrometer of Canberra for measuring radioactivity, efficiency for chemical separation was determined to be (86.1 ± 5.0)%. The experimental results for 9 subjects with urine samples to be collected during 4 operating courses of Dalat nuclear reactor with production of I-131 (from June to September, 2010) were shown that thyroid doses and effective ones for whole-body for each course of I-131 production were in ranges of from 0.11 to 13.00 mSv and from 0.01 to 0.71 mSv, respectively. Therefore, totally average doses per year for thyroid and whole-body were less than the correlative levels of permissible doses. Besides, the liquid scintillation method was also compared experimentally with the gamma spectrometry (measuring directly urine samples by the gamma spectrometer to be carried out at the Institute before) was shown that errors on dosimetric results between them were less than 12%. This was proved the dosimetry has had a confidence, and it could be applied for internal dosimetry for radiation workers contacting with unsealed sources of I-131 in radiation installations as well as for diagnostic and therapeutic patients in health ones. (author)

  2. Validation of Analysis Method of pesticides in fresh tomatoes by Gas Chromatography associated to a liquid scintillation counting

    International Nuclear Information System (INIS)

    Dhib, Ahlem

    2011-01-01

    Pesticides are nowadays considered as toxic for human health. The maximum residues levels (MRL) in foodstuff are more and more strict. Therefore, selective analytical techniques are necessary for their identification and their quantification. The aim of this study is to set up a multi residue method for the determination of pesticides in tomatoes by gas chromatography with μECD detector (GC/μECD) associated to liquid scintillation counting. A global analytical protocol consisting of a QuECHERS version of the extraction step followed by purification step of the resulting extract on a polymeric sorbent was set up. The 14 C-chloropyrifos used as an internal standard proved excellent to control the different steps needed for the sample preparation. The method optimized is specific, selective with a recovery averaged more than 70 pour cent, repetitive and reproducible. Although some others criteria need to be checked regarding validation before its use in routine analysis, the potential of the method has been demonstrated.

  3. Study of the radioactivity of drinking water in the city of Antsirabe using the method of liquid scintillation counting

    International Nuclear Information System (INIS)

    RAKOTOMANGA, H.

    2003-01-01

    The objective of this work is to determine the radioactivity by liquid scintillation counting (LSC) and to study the distribution of radionuclides in drinking water from the Antsirabe region. Optiphase Hisafe 3TM is used to measure gross alpha-beta radioactivity. Radium, radon and the excess of short half-life radionuclides are obtained from MaxilightTM cocktail. Results of measurement of drinking water samples show that : gross alpha-beta activities are between (120±27) Bq.l -1 and (426±47) Bq.l -1 , the radium activities are from (14±2)Bq.l -1 to (78±5) Bq.l -1 , radon activities are from (0.6±0.2)Bq.l -1 to (60±6) Bq.l -1 , short half-life radionuclides activities are between 25±8 Bq.l -1 and 270±27 Bq.l -1 .Annual dose exposure from ingestion of radium-226 is between (2.09 ± 0.32)mSv and (11.03 ± 0.73)mSv. These values are close to the Malagasy standard (5 mSv). The results show that drinking waters from the Antsirabe region contain natural radionuclides. Dose exposure increases if the water is directly ingested after collection. [fr

  4. Automated high performance liquid chromatography and liquid scintillation counting determination of pesticide mixture octanol/water partition rates

    International Nuclear Information System (INIS)

    Moody, R.P.; Carroll, J.M.; Kresta, A.M.

    1987-01-01

    Two novel methods are reported for measuring octanol/water partition rates of pesticides. A liquid scintillation counting (LSC) method was developed for automated monitoring of 14 C-labeled pesticides partitioning in biphasic water/octanol cocktail systems with limited success. A high performance liquid chromatography (HPLC) method was developed for automated partition rate monitoring of several constituents in a pesticide mixture, simultaneously. The mean log Kow +/- SD determined from triplicate experimental runs were for: 2,4-D-DMA (2,4-dichlorophenoxyacetic acid dimethylamine), 0.65 +/- .17; Deet (N,N-diethyl-m-toluamide), 2.02 +/- .01; Guthion (O,O-dimethyl-S-(4-oxo-1,2,3-benzotriazin-3(4H)-ylmethyl) phosphorodithioate), 2.43 +/- .03; Methyl-Parathion (O,O-dimethyl-O-(p-nitrophenyl) phosphorothioate), 2.68 +/- .05; and Fenitrothion (O,O-dimethyl O-(4-nitro-m-tolyl) phosphorothioate), 3.16 +/- .03. A strong positive linear correlation (r = .9979) was obtained between log Kow and log k' (log Kow = 2.35 (log k') + 0.63). The advantages that this automated procedure has in comparison with the standard manual shake-flask procedure are discussed

  5. Rapid Simultaneous Determination of 89Sr and 90Sr in Milk: A Procedure Using Cerenkov and Scintillation Counting

    International Nuclear Information System (INIS)

    2013-01-01

    Since 2004, the IAEA programme related to the terrestrial environment has included activities aimed at developing and testing a set of procedures for the determination of radionuclides in environmental samples. Both 89Sr and 90Sr are fission products that can be, and have been, released to the environment during nuclear explosions and nuclear reactor accidents. Since strontium uptake from milk is an important pathway for incorporation of radioactive strontium into the human body, the rapid and accurate analysis of radioactive strontium isotopes in milk is of crucial importance in emergency situations in order to protect the public from radiation hazards. This report describes a new approach for the rapid determination of 89 Sr and 90Sr in milk using Cerenkov and scintillation counting methods that was tested and validated by the analysis of four spiked milk samples in terms of repeatability, reproducibility and trueness (relative bias) in accordance with ISO guidelines. The report also describes the calculation of the uncertainty budget. This research was proposed in 2007 at the Asia-Pacific regional meeting of the IAEA Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network. Several ALMERA network laboratories participated in the validation procedure by performing reproducibility tests. The resulting recommended procedure is designed to be of general use to a wide range of laboratories, including those in the ALMERA network. It is expected that this rapid method for determining 89 Sr and 90 Sr in milk will be useful in emergency conditions and for routine environmental monitoring of elevated levels of radioactivity

  6. Preamplifier development for high count-rate, large dynamic range readout of inorganic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Keshelashvili, Irakli; Erni, Werner; Steinacher, Michael; Krusche, Bernd; Collaboration: PANDA-Collaboration

    2013-07-01

    Electromagnetic calorimeter are central component of many experiments in nuclear and particle physics. Modern ''trigger less'' detectors run with very high count-rates, require good time and energy resolution, and large dynamic range. In addition photosensors and preamplifiers must work in hostile environments (magnetic fields). Due to later constraints mainly Avalanche Photo Diodes (APD's), Vacuum Photo Triodes (VPT's), and Vacuum Photo Tetrodes (VPTT's) are used. A disadvantage is their low gain which together with other requirements is a challenge for the preamplifier design. Our group has developed special Low Noise / Low Power (LNP) preamplifier for this purpose. They will be used to equip PANDA EMC forward end-cap (dynamic range 15'000, rate 1MHz), where the PWO II crystals and preamplifier have to run in an environment cooled down to -25{sup o}C. Further application is the upgrade of the Crystal Barrel detector at the Bonn ELSA accelerator with APD readout for which special temperature comparison of the APD gain and good time resolution is necessary. Development and all test procedures after the mass production done by our group during past several years in Basel University will be reported.

  7. Standarization of Mn-54 by liquid scintillation counting using organic samples of (C8H15 O2)2 Mn-54

    International Nuclear Information System (INIS)

    1990-01-01

    A new method of standardization of Mn 54 by liquid scintillation counting with an organic sample of (C 8 H 15 O 2 ) 2 Mn 54 is described. This procedure shows a good long term stability of samples, over 20 days, and counting efficiencies between 10% and 24% for PCS e INSTAGEL and 10% 32% for a toluene-based scintillator. The discrepancies between experimental and computed values are less that 0,9% for PCS and INSTAGEL and less than 1,2% for Toluene, in the 5-2,5 interval of quenching parameter. The global uncertainty on the activity concentrat-ion of a sample standardized by this method has been lower than 3% (Author)

  8. Total alpha and beta determination by liquid scintillation counting in water samples from a Brazilian intercomparison exercise

    International Nuclear Information System (INIS)

    Dias, Fabiana F.; Taddei, Maria Helena T.; Pontedeiro, Elizabeth May Braga Dulley

    2009-01-01

    This paper describes CNEN/LAPOC's participation in the Brazilian Intercomparison Exercise (PNI) for simultaneous determination of total radioactivity in water samples, which took place in August and December 2008. The Proficiency Test (PT) also involved a short description of the nuclear analytical technique employed, emphasizing sources of uncertainty. A Liquid Scintillation System (Packard TRICARB 2700) was used with appropriate corrections applied to final results, expressed as Bq L -1 . Participation and PT data provide independent information on performance of a Laboratory and have an important role in method validation; especially because it allows the assessment of method performance over an entire range of concentrations and matrices. PT is also an important tool to demonstrate equivalence of measurements, if not their metrological comparability, and to promote education and improvement of Lab practices. (author)

  9. On the use of liquid scintillation counting of 51Cr and 14C in the twin tracer method of measuring assimilation efficiency

    International Nuclear Information System (INIS)

    Cammen, L.M.

    1977-01-01

    Calow and Fletcher (1972) calculated assimilation efficiency from the ratio of an assimilated radiotracer ( 14 C) to a non-assimilated tracer ( 51 Cr) in food and feces. Wightman (1975) improved the efficiency of their technique by using liquid scintillation to count both isotopes simultaneously, but stated incorrectly that it was not necessary to convert count per minute (CPM) to disintegration per minute (DPM). Unless the CPM data are corrected for quenching and converted to DPM prior to calculation of assimilation efficiency, a significant error may be introduced. (orig.) [de

  10. Stability and reproducibility of gel-suspension samples for the liquid scintillation counting of 14C using N-lauroyl-L-glutamic-α,γ-dibutylamide

    International Nuclear Information System (INIS)

    Wakabayashi, G.; Ohura, H.; Okai, T.; Matoba, M.

    1999-01-01

    Stability and reproducibility of gel-suspension method for 14 C activity measurement. Commercially available gelling agent, N-lauroyl-L-glutamic-α,γ-dibutylamide, was used for the gel-formation of the samples. No change of the counting rate for the gel-suspension sample was observed for more than 2 years after the sample preparation. Four samples used for checking the reproducibility of the sample preparation method. The same values were obtained for the counting rate of 14 C activity within the counting error. No change of the counting rate was observed for the 're-gelated' sample. These results show that the gel-suspension method is appropriate for the 14 C activity measurement by the liquid scintillation method and is useful for a long-term preservation of the sample for repeated measurement. (author)

  11. Multiple comparative metagenomics using multiset k-mer counting

    Directory of Open Access Journals (Sweden)

    Gaëtan Benoit

    2016-11-01

    Full Text Available Background Large scale metagenomic projects aim to extract biodiversity knowledge between different environmental conditions. Current methods for comparing microbial communities face important limitations. Those based on taxonomical or functional assignation rely on a small subset of the sequences that can be associated to known organisms. On the other hand, de novo methods, that compare the whole sets of sequences, either do not scale up on ambitious metagenomic projects or do not provide precise and exhaustive results. Methods These limitations motivated the development of a new de novo metagenomic comparative method, called Simka. This method computes a large collection of standard ecological distances by replacing species counts by k-mer counts. Simka scales-up today’s metagenomic projects thanks to a new parallel k-mer counting strategy on multiple datasets. Results Experiments on public Human Microbiome Project datasets demonstrate that Simka captures the essential underlying biological structure. Simka was able to compute in a few hours both qualitative and quantitative ecological distances on hundreds of metagenomic samples (690 samples, 32 billions of reads. We also demonstrate that analyzing metagenomes at the k-mer level is highly correlated with extremely precise de novo comparison techniques which rely on all-versus-all sequences alignment strategy or which are based on taxonomic profiling.

  12. A Procedure for the Sequential Determination of Radionuclides in Environmental Samples. Liquid Scintillation Counting and Alpha Spectrometry for 90Sr, 241Am and Pu Radioisotopes

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, IAEA activities related to the terrestrial environment have aimed at the development of a set of procedures to determine radionuclides in environmental samples. Reliable, comparable and ‘fit for purpose’ results are an essential requirement for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of analytical data. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available for reference to both the analyst and the customer. This publication describes a combined procedure for the sequential determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples. The method is based on the chemical separation of strontium, americium and plutonium using ion exchange chromatography, extraction chromatography and precipitation followed by alpha spectrometric and liquid scintillation counting detection. The method was tested and validated in terms of repeatability and trueness in accordance with International Organization for Standardization (ISO) guidelines using reference materials and proficiency test samples. Reproducibility tests were performed later at the IAEA Terrestrial Environment Laboratory. The calculations of the massic activity, uncertainty budget, decision threshold and detection limit are also described in this publication. The procedure is introduced for the determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples such as soil, sediment, air filter and vegetation samples. It is expected to be of general use to a wide range of laboratories, including the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network for routine environmental monitoring purposes

  13. A Procedure for the Sequential Determination of Radionuclides in Phosphogypsum Liquid Scintillation Counting and Alpha Spectrometry for 210Po, 210Pb, 226Ra, Th and U Radioisotopes

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, the Environment Programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Reliable, comparable and 'fit for purpose' results are essential requirements for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of such analytical data. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. In this publication, a combined procedure for the sequential determination of 210Po, 210Pb, 226Ra, Th and U radioisotopes in phosphogypsum is described. The method is based on the dissolution of small amounts of phosphogypsum by microwave digestion, followed by sequential separation of 210Po, 210Pb, Th and U radioisotopes by selective extraction chromatography using Sr, TEVA and UTEVA resins. Radium-226 is separated from interfering elements using Ba(Ra)SO4 co-precipitation. Lead-210 is determined by liquid scintillation counting. The alpha source of 210Po is prepared by autodeposition on a silver plate. The alpha sources of Th and U are prepared by electrodeposition on a stainless steel plate. A comprehensive methodology for the calculation of results, including the quantification of measurement uncertainty, was also developed. The procedure is introduced as a recommended procedure and validated in terms of trueness, repeatability and reproducibility in accordance with ISO guidelines

  14. Imaging performance comparison between a LaBr3: Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera.

    Science.gov (United States)

    Russo, P; Mettivier, G; Pani, R; Pellegrini, R; Cinti, M N; Bennati, P

    2009-04-01

    The authors report on the performance of two small field of view, compact gamma cameras working in single photon counting in planar imaging tests at 122 and 140 keV. The first camera is based on a LaBr3: Ce scintillator continuous crystal (49 x 49 x 5 mm3) assembled with a flat panel multianode photomultiplier tube with parallel readout. The second one belongs to the class of semiconductor hybrid pixel detectors, specifically, a CdTe pixel detector (14 x 14 x 1 mm3) with 256 x 256 square pixels and a pitch of 55 microm, read out by a CMOS single photon counting integrated circuit of the Medipix2 series. The scintillation camera was operated with selectable energy window while the CdTe camera was operated with a single low-energy detection threshold of about 20 keV, i.e., without energy discrimination. The detectors were coupled to pinhole or parallel-hole high-resolution collimators. The evaluation of their overall performance in basic imaging tasks is presented through measurements of their detection efficiency, intrinsic spatial resolution, noise, image SNR, and contrast recovery. The scintillation and CdTe cameras showed, respectively, detection efficiencies at 122 keV of 83% and 45%, intrinsic spatial resolutions of 0.9 mm and 75 microm, and total background noises of 40.5 and 1.6 cps. Imaging tests with high-resolution parallel-hole and pinhole collimators are also reported.

  15. Liquid scintillation counting

    International Nuclear Information System (INIS)

    Bunge, F.

    1986-01-01

    The methods applied for quench corrections in LSC rely on radioactivity standard sources as reference materials. For determining the quenching effect effect, there are methods based on the sample channel ratio, or the spectral quench parameter determination, or determination of the H-number. Currently available LSC equipment is briefly described. (DG) [de

  16. A Fast Dynamic 64-bit Comparator with Small Transistor Count

    Directory of Open Access Journals (Sweden)

    Chua-Chin Wang

    2002-01-01

    Full Text Available In this paper, we propose a 64-bit fast dynamic CMOS comparator with small transistor count. Major features of the proposed comparator are the rearrangement and re-ordering of transistors in the evaluation block of a dynamic cell, and the insertion of a weak n feedback inverter, which helps the pull-down operation to ground. The simulation results given by pre-layout tools, e.g. HSPICE, and post-layout tools, e.g. TimeMill, reveal that the delay is around 2.5 ns while the operating clock rate reaches 100 MHz. A physical chip is fabricated to verify the correctness of our design by using UMC (United Microelectronics Company 0.5 μm (2P2M technology.

  17. Studying, Determining The Radionuclide Of Tritum In The Water Samples (Rain, Surface Water) By Using Liquid Scintillation Counting (TRi-carb 3180TR/SL)

    International Nuclear Information System (INIS)

    Nguyen Thi Linh; Nguyen Dinh Tung; Truong Y; Le Nhu Sieu; Nguyen Van Phuc; Nguyen Van Phu; Nguyen Kim Thanh

    2014-01-01

    Tritium in the environment is of natural or man-made origin. Tritium is a radioactive isotope that occurs in the environment and is associated with the interaction of cosmic ray in the atmosphere. However, the most significant sources of tritium in the environment results from nuclear weapons testing in the atmosphere carried out during the late 1950s and early 1960s. Today, the most important new sources of tritium in the environments, such as power stations, processing and using of isotopes released the local tritium. The objective of this study is the application of the liquid scintillation technique to tritium analysis in water samples (rain, and surface waters). Following the Eichrom Tritium Column technique, an aliquot of the passed tritium resin sample (10 mL) is mixed with 10 mL of scintillation cocktail (Ultima Gold LLT, Packard) in 20-mL plastic- container vials and the sample activity is determined using a liquid scintillation spectrometer, Tri-carb 3180TR/SL. Counting efficiency is evaluated with internal standards. The tritium concentrations of water samples that were collected from DaLat, Lamdong range between 0 to 36.2 TU. (author)

  18. A comparative study of 19-iodo cholesterol-125I 3-acetate and Na 125I in liquid scintillation measurements; Estudio comparativo del acetato de 19-iodocolesterol- -125I con Nal25I en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-07-01

    A comparative study of performance of 19-iodo cholesterol {sup 1}25I 3-acetate and sodium iodide samples labeled with 125I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I concentration of 0-90 {mu}g and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol 1 I 3-acetate samples in Tolue ne-alcohol and 0 .04% for Na 125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs.

  19. Analytical method of Kr-85 determination, using cryogenic concentration and separation and liquid scintillation counting; Desarrollo del metodo de concentracion y se paracion criogenica cromatografica y medida radiactiva por centelleo liquido de Kr-85

    Energy Technology Data Exchange (ETDEWEB)

    Heras, M C; Perez, M M; Grau, A

    1983-07-01

    The method used in the Laboratory of the JEN for the determination of Kr-85 levels in gaseous effluents of nuclear power and in the atmosphere is described. Samples of air, collected in metallic cylinders, are introduced into a gas-solid chromatographic separation system which resolves Kr from the other air components. The separated Kr ia dissolved in a toluene based scintillation cocktail, and the Kr-85 content is determined by liquid scintillation counting. (Author)

  20. Stability and counting losses of Li sup 36 CL samples in liquid scintillation measurements. Evaluacion de la estabilidad y perdidas de recuento de muestras de Li sup 36 CL en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Grau, A.; Rodriguez, L.; Los Arcos, J.M.

    1990-01-01

    A systematic study of several factors concerning the liquid scintillation counting efficiency of Li{sup 36}CL samples in ethanolic solutions has been carried out. The stability of samples containing less than 1.2 Bq/{mu}l of Li{sup 36}Cl in ethanol, added to a toluene-based scintillator is enterely satisfactory. Samples with higher concentration show counting losses than can reach up to 29% of the optimal values along 24 hours. After regeneration of unstable samples by progressive ethanol dilution, the counting efficiency remains always lower than 98% of the best value. Nevertheless the counting rate obtained can be predicted as an exponential function of the dilution degree or activity concentration in the sample. The spectral degradation can be taken into account by defining a parameter, {delta}, wich allows to evaluate the counting loss correction in a sample as a rational function of {delta} (Author)

  1. Solid scintillator 'Ready Cap' for measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Ijiri, Kenichi; Endo, Masashi; Nogawa, Norio; Tsuda, Shoko; Nakamura, Aiko; Morikawa, Naotake; Osaki, Susumu.

    1990-01-01

    'Ready Cap', a small plastic container coated with solid scintillator has recently been introduced (Beckman Instruments, Inc.). Pulse height spectra and counting efficiencies obtained with a liquid scintillator and Ready Cap using a liquid scintillation counter were compared for 15 different radionuclides. For radionuclides emitting low-energy β-rays or characteristic X-rays, the spectra for Ready Cap shifted toward the higher energy side compared with the spectra for the liquid scintillator. This tendency was reversed for the nuclides emitting higher-energy β-radiations ( 36 Cl and 32 P). Generally, counting efficiencies both in Ready Cap and in liquid scintillator increased with increase in the energy of β- or X-rays. For some nuclides, Ready Cap gave higher counting efficiencies and for others it gave lower values than in the liquid scintillator. However, the differences were not large within each nuclide. The use of Ready Cap is recommended for measurements of radionuclides when liquid scintillation cocktails have no means of waste disposal under the present Japanese radioisotope regulation. (author)

  2. PPO-ethanol system as wavelength shifter for the Cherenkov counting technique using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Takiue, M.; Fujii, H.; Ishikawa, H.

    1984-01-01

    2,5-diphenyloxazole (PPO) has been proposed as a wavelength shifter for Cherenkov counting. Since PPO is not incorporated with water, we have introduced the fluor into water in the form of micelle using a PPO-ethanol system. This technique makes it possible to obtain a high Cherenkov counting efficiency under stable sample conditions, attributed to the proper spectrometric features of the PPO. The 32 P Cherenkov counting efficiency (68.4%) obtained from this technique is 1.62 times as large as that measured with a conventional Cherenkov technique. (orig.)

  3. An improved method for {sup 85}Kr analysis by liquid scintillation counting and its application to atmospheric {sup 85}Kr determination

    Energy Technology Data Exchange (ETDEWEB)

    Momoshima, Noriyuki, E-mail: momoshima.noriyuki.551@m.kyushu-u.ac.j [Radioisotope Center, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan); Inoue, Fumio [Graduate School of Science, Kyushu University, 6-10-1Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan); Sugihara, Shinji [Radioisotope Center, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan); Shimada, Jun [Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Taniguchi, Makoto [Research Institute for Humanity and Nature, 457-4 Motoyama Kamigamo, Kita-ku, Kyoto 603-8047 (Japan)

    2010-08-15

    Atmospheric {sup 85}Kr concentration at Fukuoka, Japan was determined by an improved {sup 85}Kr analytical method using liquid scintillation counting (LSC). An average value of 1.54 {+-} 0.05 Bq m{sup -3} was observed in 2008, which is about two times that measured in 1981 at Fukuoka, indicating a 29 mBq y{sup -1} rate of increase as an average for these 27 years. The analytical method developed involves collecting Kr from air using activated charcoal at liquid N{sub 2} temperature and purifying it using He at dry ice temperature, followed by Kr separation by gas chromatography. An overall Kr recovery of 76.4 {+-} 8.1% was achieved when Kr was analyzed in 500-1000 l of air. The Kr isolated by gas chromatography was collected on silica gel in a quartz glass vial cooled to liquid N{sub 2} temperature and the activity of {sup 85}Kr was measured with a low-background LS counter. The detection limit of {sup 85}Kr activity by the present analytical method is 0.0015 Bq at a 95% confidence level, including all propagation errors, which is equivalent with {sup 85}Kr in 1.3 l of the present air under the analytical conditions of 72.1% counting efficiency, 0.1597 cps background count rate, and 76.4% Kr recovery.

  4. Optimization of 14C liquid scintillation counting of plant and soil lipids to trace short term formation, translocation and degradation of lipids

    International Nuclear Information System (INIS)

    Wiesenberg, G.L.B.; Gocke, M.; Yakov Kuzyakov

    2010-01-01

    Two powerful approaches are frequently used to trace incorporation and degradation of plant derived C in soil: 14 C labelling/chasing and analysis of lipid composition. In this study, we coupled these approaches in order to trace short term incorporation of plant derived lipids into rhizosphere and non-rhizosphere soil. Methodological optimization was required and implied 14 C liquid scintillation counting improvement for plant lipid extracts taking into account organic solvents, solvent-to-scintillation cocktail ratio, and amount of lipids. Following method optimization, 14 C data of fatty acids indicated a notable contribution of root derived lipids to rhizosphere and non-rhizosphere soil. Coupling of 14 C labelling/chasing with lipid analysis is a powerful and cheap approach for tracing of root derived C in soil allowing for estimation of C budget, for determination of C formation and translocation within plants and from plant to soil, as well as for identification of short term dynamics of specific compound classes within soil. (author)

  5. Trainable estimators for indirect people counting : a comparative study

    NARCIS (Netherlands)

    Acampora, G.; Loia, V.; Percannella, G.; Vento, M.

    2011-01-01

    Estimating the number of people in a scene is a very relevant issue due to the possibility of using it in a large number of contexts where it is necessary to automatically monitor an area for security/safety reasons, for economic purposes, etc. The large number of people counting approaches

  6. Measurement of 103mRh produced by the 103Rh(γ,γ')103mRh reaction with liquid scintillation counting

    International Nuclear Information System (INIS)

    Sekine, T.; Yoshihara, Kenji; Pavlicsek, I.; Lakosi, L.; Veres, A.

    1989-01-01

    A liquid scintillation counting technique was applied to measure the isotope 103m Rh (half life = 56.12 min) which is difficult to detect because its γ-ray is of low energy and low emission probability. Tris-(2,4-pentanedionato)rhodium(III) (Rh(acac) 3 ) was irradiated with bremsstrahlung of accelerated 3.2 MeV electrons by LINAC. The method has given a reliable calibration curve for the determination of 103m Rh radioactivity below Rh(acac) 3 concentrations of 2 mM. The integrated cross section of 103 Rh(γ,γ') 103m Rh determined by this method was found to be 6.8±3.4 μb MeV at 3.2 MeV. (author) 8 refs.; 5 figs

  7. Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators

    International Nuclear Information System (INIS)

    Archambault, Louis; Arsenault, Jean; Gingras, Luc; Sam Beddar, A.; Roy, Rene; Beaulieu, Luc

    2005-01-01

    Scintillation dosimetry is a promising avenue for evaluating dose patterns delivered by intensity-modulated radiation therapy plans or for the small fields involved in stereotactic radiosurgery. However, the increase in signal has been the goal for many authors. In this paper, a comparison is made between plastic scintillating fibers and plastic scintillator. The collection of scintillation light was measured experimentally for four commercial models of scintillating fibers (BCF-12, BCF-60, SCSF-78, SCSF-3HF) and two models of plastic scintillators (BC-400, BC-408). The emission spectra of all six scintillators were obtained by using an optical spectrum analyzer and they were compared with theoretical behavior. For scintillation in the blue region, the signal intensity of a singly clad scintillating fiber (BCF-12) was 120% of that of the plastic scintillator (BC-400). For the multiclad fiber (SCSF-78), the signal reached 144% of that of the plastic scintillator. The intensity of the green scintillating fibers was lower than that of the plastic scintillator: 47% for the singly clad fiber (BCF-60) and 77% for the multiclad fiber (SCSF-3HF). The collected light was studied as a function of the scintillator length and radius for a cylindrical probe. We found that symmetric detectors with nearly the same spatial resolution in each direction (2 mm in diameter by 3 mm in length) could be made with a signal equivalent to those of the more commonly used asymmetric scintillators. With augmentation of the signal-to-noise ratio in consideration, this paper presents a series of comparisons that should provide insight into selection of a scintillator type and volume for development of a medical dosimeter

  8. Coincidence and noncoincidence counting (81Rb and 43K): a comparative study

    International Nuclear Information System (INIS)

    Ikeda, S.; Duken, H.; Tillmanns, H.; Bing, R.J.

    1975-01-01

    The accuracy of imaging and resolution obtained with 81 Rb and 43 K using coincidence and noncoincidence counting was compared. Phantoms and isolated infarcted dog hearts were used. The results clearly show the superiority of coincidence counting with a resolution of 0.5 cm. Noncoincidence counting failed to reveal even sizable defects in the radioactive source. (U.S.)

  9. Liquid Scintillation Counting Standardization of {sup 2}2NaCl by te CIEMAT/NIST method; Calibracion por Centelleo Liquido del ''22NaCl, mediante el metodo CIEMAT/NIST

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-07-01

    We describe a procedure for preparing a stable solution of ''22NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4 % and an overall uncertainty of 0.35 %. (Author) 4 refs.

  10. High Resolution Gamma Ray Spectroscopy at MHz Counting Rates With LaBr3 Scintillators for Fusion Plasma Applications

    Science.gov (United States)

    Nocente, M.; Tardocchi, M.; Olariu, A.; Olariu, S.; Pereira, R. C.; Chugunov, I. N.; Fernandes, A.; Gin, D. B.; Grosso, G.; Kiptily, V. G.; Neto, A.; Shevelev, A. E.; Silva, M.; Sousa, J.; Gorini, G.

    2013-04-01

    High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out at nuclear accelerators, combining a LaBr 3(Ce) detector with dedicated hardware and software solutions based on digitization and off-line analysis. Spectra were measured at counting rates up to 4 MHz, with little or no degradation of the energy resolution, adopting a pile up rejection algorithm. The reported results represent a step forward towards the final goal of high resolution γ-ray spectroscopy measurements on a burning plasma device.

  11. Determination of radiostrontium released from Fukushima Daiichi Nuclear Power Plant through extraction chromatography and liquid scintillation counting

    International Nuclear Information System (INIS)

    Maekawa, Akihiro; Momoshima, Noriyuki; Sugihara, Shinji; Tamari, Toshiya

    2013-01-01

    Two soil samples were collected on April 18-20, 2011 at Namie town and Tomioka town, which are located 26 km northwest and 11 km south of the Fukushima Daiichi Nuclear Power Plant, respectively. A 0-1 cm soil layer was used for analysis to determine the presence of radiostrontium. The soil was ashed, acid-digested, and strontium was separated from interference with use of an extraction chromatography resin (Sr resin, Eichrom Technologies). The isolation and purification of strontium from matrix components can be completed in 12 h. After 2 weeks for ingrowth of "9"0Y, measurements of a beta-ray of "9"0Y and "8"9"+"9"0Sr were conducted with a low-background liquid-scintillation counter for 1200 min. The concentration of "9"0Sr was determined to be 57.4 ± 1.0 and 10.1 ± 0.4 Bq kg"-"1 for Namie town and Tomioka town, respectively. "8"9Sr was not detected in either sample. The extraction chromatography method was successfully applied to determine the level of radiostrontium in the contaminated soil. When 2 g of soil is used, the detection limit of "9"0Sr is evaluated to be 2.7 Bq kg"-"1 under a chemical yield of strontium of 70%. (author)

  12. Comparing MapReduce and Pipeline Implementations for Counting Triangles

    Directory of Open Access Journals (Sweden)

    Edelmira Pasarella

    2017-01-01

    Full Text Available A common method to define a parallel solution for a computational problem consists in finding a way to use the Divide and Conquer paradigm in order to have processors acting on its own data and scheduled in a parallel fashion. MapReduce is a programming model that follows this paradigm, and allows for the definition of efficient solutions by both decomposing a problem into steps on subsets of the input data and combining the results of each step to produce final results. Albeit used for the implementation of a wide variety of computational problems, MapReduce performance can be negatively affected whenever the replication factor grows or the size of the input is larger than the resources available at each processor. In this paper we show an alternative approach to implement the Divide and Conquer paradigm, named dynamic pipeline. The main features of dynamic pipelines are illustrated on a parallel implementation of the well-known problem of counting triangles in a graph. This problem is especially interesting either when the input graph does not fit in memory or is dynamically generated. To evaluate the properties of pipeline, a dynamic pipeline of processes and an ad-hoc version of MapReduce are implemented in the language Go, exploiting its ability to deal with channels and spawned processes. An empirical evaluation is conducted on graphs of different topologies, sizes, and densities. Observed results suggest that dynamic pipelines allows for an efficient implementation of the problem of counting triangles in a graph, particularly, in dense and large graphs, drastically reducing the execution time with respect to the MapReduce implementation.

  13. Simultaneous determination of environmental α-radionuclides using liquid scintillation counting combined with time interval analysis (TIA) and pulse shape discrimination (PSD)

    International Nuclear Information System (INIS)

    Hashimoto, T.; Sato, K.; Yoneyama, Y.; Fukuyama, N.

    1997-01-01

    Some improvements of the detection sensitivity in pulse time interval analysis (TIA) based on selective extraction of successively α-α correlated decay events within millisecond order from random or background events, were established by the utilization of PSD, to reject β/γ-pulses from α-ones and a simple chemical procedure of radium separation, together with the use of well resolved scintillator. By applying the PSD, the contribution of β-decay events was completely eliminated in both the α-spectra and the TIA distribution curves as well as the improvement into clear energy resolution and the enhancement of detection sensitivity for the TIA. As a result, the TIA and α-spectrometric analysis of 226 Ra-extract showed the existence of 223 Ra (Ac-series) and β/α-correlated events with correlated life (due to 0.16 ms due to 214 Bi(β)-> 214 Po(α)->) along with a singly well resolved α-peak to be useful for the determination of 226 Ra (U-series). The difference of half-lives (145 and 1.78 ms) due to 216 Po and 215 Po (direct daughters of 224 Ra for Th-series and 223 Ra for Ac-series, respectively) was also proven for the possibility of the simultaneous determination of both correlated events by using the TIA/PSD combined with chemical separation and liquid scintillation counting method. Finally, the simultaneous determination of three natural decay series, which include U-, Th- and Ac-series nuclides, have been conveniently carried out for some environmental samples using the present method combined with 225 Ra yield tracer (Np-series). (author)

  14. Liquid scintillation counting standardization of 125I in organic and inorganic samples by the CIEMAT/NIST method; Calibracion por centelleo liquido del 125I en muestras inorganicas y organicas, mediante el metodo CIEMAT/NIST

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-07-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''I25I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%. (Author) 14 refs.

  15. Application of low background liquid scintillation counting method to pharmacy. Variation of endogenous 14C in human urine

    International Nuclear Information System (INIS)

    Horie, Masanobu; Yanagi, Mashiho; Baba, Shigeo; Kato, Yuka; Yoshimura, Tomoyuki

    2010-01-01

    The intra-day, inter-day and individual variations in endogenous 14 C radioactivity of human urine were studied by use of 5 mL urine. The endogenous 14 C radioactivity of human urine is relatively constant (approximately 1.5 dpm/mL urine). In order to eliminate the effect of endogenous 40 K it is of the greatest importance to count 14 C signal with the optimal window. Since these variations are relatively small, we can estimate correctly the net 14 C activity from the BG value of the same time zone of the day before dosing. (author)

  16. Connection of comparator circuit for pseudocoincidence counting of radioactive aerosols

    International Nuclear Information System (INIS)

    Fukatko, T.; Hajek, P.; Vidra, M.

    1985-01-01

    A block diagram is presented of the radioactive aerosol measuring instrument. The first counter records electric pulses corresponding to gross alpha activity and the second indicates pseudocoincidences derived from natural radioactivity. Data from the counters are converted to analog voltages which in the comparator circuit are compared such that the mean value of the output voltage is zero insofar as artificial radioactivity is not present on the filter. The designed connection of the comparator circuit allows the permanent adjustment of the whole measuring equipment to maximum sensitivity. (E.S.)

  17. Survey on the presence of 90Sr in milk samples by a validated ultra low level liquid scintillation counting (LSC method

    Directory of Open Access Journals (Sweden)

    dell’Oro D.

    2013-04-01

    Full Text Available 90Sr is one of the most biologically hazardous radionuclides produced in nuclear fission processes and decays emitting high-energy beta particles turning 90Y. 90Sr is transferred from soil-plant to cow’s milk and then to humans if it is introduced into the environment. Radiostrontium is chemically similar to calcium entering the human body through several food chains and depositing in bone and blood-forming tissue (bone marrow. Among main foodstuffs assumed in human diet, milk is considered of special interest for radiostrontium determination, especially in emergency situations, because the consumption of contaminated milk is the main source of internal radiation exposure, particularly for infants. In this work an analytical method for the determination of radiostrontium in milk was developed and validated in order to determine low activity levels by liquid scintillation counting (LSC after achieving 90Y secular equilibrium condition. The analytical procedure was applied both in surveillance and routine programmes to detect radiocontamination in cow’s, goat and sheep milk samples.

  18. Radiostrontium accumulation in animal bones: development of a radiochemical method by ultra low-level liquid scintillation counting for its quantification.

    Science.gov (United States)

    Iammarino, Marco; Dell'Oro, Daniela; Bortone, Nicola; Mangiacotti, Michele; Chiaravalle, Antonio Eugenio

    2018-03-31

    Strontium-90 (90Sr) is a fission product, resulting from the use of uranium and plutonium in nuclear reactors and weapons. Consequently, it may be found in the environment as a consequence of nuclear fallouts, nuclear weapon testing, and not correct waste management. When present in the environment, strontium-90 may be taken into animal body by drinking water, eating food, or breathing air. The primary health effects are bone tumors and tumors of the blood-cell forming organs, due to beta particles emitted by both 90Sr and yttrium-90 (90Y). Moreover, another health concern is represented by inhibition of calcification and bone deformities in animals. Actually, radiometric methods for the determination of 90Sr in animal bones are lacking. This article describers a radiochemical method for the determination of 90Sr in animal bones, by ultra low-level liquid scintillation counting. The method precision and trueness have been demonstrated through validation tests (CV% = 12.4%; mean recovery = 98.4%). Detection limit and decision threshold corresponding to 8 and 3 mBecquerel (Bq) kg-1, respectively, represent another strong point of this analytical procedure. This new radiochemical method permits the selective extraction of 90Sr, without interferences, and it is suitable for radiocontamination surveillance programs, and it is also an improvement with respect to food safety controls.

  19. Determination of radium isotopes in environmental samples by gamma spectrometry, liquid scintillation counting and alpha spectrometry: a review of analytical methodology

    International Nuclear Information System (INIS)

    Jia, Guogang; Jia, Jing

    2012-01-01

    Radium (Ra) isotopes are important from the viewpoints of radiation protection and environmental protection. Their high toxicity has stimulated the continuing interest in methodology research for determination of Ra isotopes in various media. In this paper, the three most routinely used analytical techniques for Ra isotope determination in biological and environmental samples, i.e. low-background γ-spectrometry, liquid scintillation counting and α-spectrometry, were reviewed, with emphasis on new methodological developments in sample preparation, preconcentration, separation, purification, source preparation and measurement techniques. The accuracy, selectivity, traceability, applicability and minimum detectable activity (MDA) of the three techniques were discussed. It was concluded that the MDA (0.1 mBq L −1 ) of the α-spectrometry technique coupled with chemical separation is about two orders of magnitude lower than that of low-background HPGe γ-spectrometry and LSC techniques. Therefore, when maximum sensitivity is required, the α-spectrometry technique remains the first choice. - Highlights: ► A review is made for determination of Ra isotopes in environmental samples. ► Gamma spectrometry, LSC and a-spectrometry are the main concerned radiometric approach. ► Sample preparation, preconcentration, separation and source preparation are discussed. ► The methods can analyse air, water, seawater, soil, sediment and foodstuffs samples. ► Some new data obtained recently from our laboratory for Ra method study are included.

  20. Beta emitter radionuclides (90Sr contamination in animal feed: validation and application of a radiochemical method by ultra low level liquid scintillation counting

    Directory of Open Access Journals (Sweden)

    Marco Iammarino

    2015-02-01

    Full Text Available 90Sr is considered as a dangerous contaminant of agri-food supply chains due to its chemical affinity with Calcium, which makes its absorption in bones easy. 90Sr accumulation in raw materials and then in final products is particularly significant in relationship to its ability to transfer into animal source products. The radionuclides transfer (137Cs and 90Sr from environment to forages and then to products of animal origin (milk, cow and pork meats was studied and evaluated in different studies, which were carried out in contaminated areas, from Chernobyl disaster until today. In the present work, the development and validation of a radiochemical method for the detection of 90Sr in different types of animal feed, and the application of this technique for routinely control activities, are presented. Liquid scintillation counting was the employed analytical technique, since it is able to determine very low activity concentrations of 90Sr (<0.01 Bq kg–1. All samples analysed showed a 90Sr contamination much higher than method detection limit (0.008 Bq kg–1. In particular, the highest mean activity concentration was registered in hay samples (2.93 Bq kg–1, followed by silage samples (2.07 Bq kg–1 and animal feeds (0.77 Bq kg–1. In fact, all samples were characterized by 90Sr activity concentrations much lower than reference limits. This notwithstanding, the necessity to monitor these levels was confirmed, especially considering that 90Sr is a possible carcinogen for human.

  1. Applications of liquid scintillation tubes

    International Nuclear Information System (INIS)

    Broga, D.W.

    1977-01-01

    A new cocktail containing device for liquid scintillation counting, the scintillation tube, consists of a two-layered plastic bag which is heatsealed after the cocktail and sample have been placed in it. It is then placed in a carrying vial and counted in a conventional liquid scintillation counter. These tubes have proved to be a practical and economical alternative to vials. Some of their advantages are elimination of absorption problems, transparency, lower background and higher counting efficiency, low breakage danger and savings in waste disposal costs. Two applications for which the tubes are particularly suitable are the counting of laboratory swipes and urine analysis. (author)

  2. Influence of atomic and nuclear constants on the counting efficiency for 55{sup F}e in liquid scintillators; Influencia de los parametros atomicos y nucleares en la calibracion de 55{sup F}e mediante centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, A.; Grau, A.; Arcos, J. M. los

    1985-07-01

    In this paper one considers the influence of the different parameters on the determination of the uncertainty of the detection efficiency for 55{sup F}e when the counting technique of liquid scintillation is applied. The following parameters are considered: the relative probabilities of X and Auger emission so as their corresponding energies, the fluorescence yields W{sup K} and W{sup L}, and the non-interaction probabilities of the emitted X photons. (Author) 11 refs.

  3. Comparative measurements between a Li-6 glass and a He-3 high-pressure gas scintillator

    International Nuclear Information System (INIS)

    Priesmeyer, H.G.; Fischer, P.; Harz, U.; Soldner, B.

    1983-01-01

    The He-3 high-pressure gas scintillation neutron detector commercially available as LND 800, has been compated to a Li-6 glass scintillator type NE 912. (n,γ) pulse height discrimination capabilities and neutron detection efficiencies have been determined. The objective of these measurements was to try to improve the Kiel Fast-Chopper TOF detector system by using a gasscintillator, which could cover the neutron beam geometry and by which gamma ray background contributions could be reduced. The time response always meets the requirements of a chopper experiment, but the neutron detection efficiency of the Li-6 glasses now used had to be maintained. (orig./HP) [de

  4. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  5. The use of energy information in plastic scintillator materia

    International Nuclear Information System (INIS)

    Ely, J.; Anderson, K.; Bates, D.; Kouzes, R.; Lo Presti, C.; Runkle, R.; Siciliano, E.; Weier, D.

    2008-01-01

    Plastic scintillator material is often used for gamma-ray detection in many applications due to its relatively good sensitivity and cost-effectiveness compared to other detection materials. However, due to the dominant Compton scattering interaction mechanism, full energy peaks are not observed in plastic scintillator spectra and isotopic identification is impossible. Typically plastic scintillator detectors are solely gross count detectors. In some safeguards and security applications, such as radiation portal monitors for vehicle screening, naturally-occurring radioactive material (NORM) often triggers radiation alarms and results in innocent or nuisance alarms. The limited energy information from plastic scintillator material can be used to discriminate the NORM from targeted materials and reduce the nuisance alarm rate. An overview of the utilization of the energy information from plastic scintillator material will be presented, with emphasis on the detection capabilities and potential limitations for safeguards and security applications. (author)

  6. A new value for the half-life of {sup 10}Be by Heavy-Ion Elastic Recoil Detection and liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Korschinek, G., E-mail: Gunther.Korschinek@ph.tum.d [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Bergmaier, A. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Faestermann, T. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Gerstmann, U.C. [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstaedter Landstr. 1, D-85764 Neuherberg (Germany); Knie, K.; Rugel, G. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Wallner, A. [VERA Laboratory, Faculty of Physics, University of Vienna, Waehringer Strasse 17, A-1090 Wien (Austria); Dillmann, I. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Dollinger, G. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Lierse von Gostomski, Ch. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany); Kossert, K. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Maiti, M.; Poutivtsev, M. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Remmert, A. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany)

    2010-01-15

    The importance of {sup 10}Be in different applications of accelerator mass spectrometry (AMS) is well-known. In this context the half-life of {sup 10}Be has a crucial impact, and an accurate and precise determination of the half-life is a prerequisite for many of the applications of {sup 10}Be in cosmic-ray and earth science research. Recently, the value of the {sup 10}Be half-life has been the centre of much debate. In order to overcome uncertainties inherent in previous determinations, we introduced a new method of high accuracy and precision. An aliquot of our highly enriched {sup 10}Be master solution was serially diluted with increasing well-known masses of {sup 9}Be. We then determined the initial {sup 10}Be concentration by least square fit to the series of measurements of the resultant {sup 10}Be/{sup 9}Be ratio. In order to minimize uncertainties because of mass bias which plague other low-energy mass spectrometric methods, we used for the first time Heavy-Ion Elastic Recoil Detection (HI-ERD) for the determination of the {sup 10}Be/{sup 9}Be isotopic ratios, a technique which does not suffer from difficult to control mass fractionation. The specific activity of the master solution was measured by means of accurate liquid scintillation counting (LSC). The resultant combination of the {sup 10}Be concentration and activity yields a {sup 10}Be half-life of T{sub 1/2} = 1.388 +- 0.018 (1 s, 1.30%) Ma. In a parallel but independent study (Chmeleff et al. ), found a value of 1.386 +- 0.016 (1.15%) Ma. Our recommended weighted mean and mean standard error for the new value for {sup 10}Be half-life based on these two independent measurements is 1.387 +- 0.012 (0.87%) Ma.

  7. Comparison of analysis techniques by liquid scintillation and Cerenkov Effect for 40K quantification in aqueous samples

    International Nuclear Information System (INIS)

    Miranda C, L.; Davila R, J. I.; Lopez del R, H.; Mireles G, F.

    2015-09-01

    In this work the counting by liquid scintillation and Cerenkov Effect to quantify 40 K in aqueous samples was used. The performance of both techniques was studied by comparing the response of three commercial liquid scintillation OptiPhase HiSafe 3, Ultima Gold Ab and OptiPhase TriSafe, the vial type and presentation conditions of the sample for counting. In liquid scintillation, the ability to form homogeneous mixtures depended on the ionic strength of the aqueous solutions. The scintillator OptiPhase HiSafe 3 showed a greater charge capacity for solutions with high ionic strength (<3.4), while the scintillator OptiSafe TriSafe no form homogeneous mixtures for solutions of ionic strength higher than 0.3. Counting efficiencies for different proportions of sample and scintillator near 100% for the scintillators OptiSafe HiSafe 3 and Ultima Gold Ab were obtained. In the counting by Cerenkov Effect, the efficiency and sensitivity depended of the vial type; polyethylene vials were more suitable for counting that the glass vials. The sample volume had not significant effect on counting efficiency, obtaining an average value of 44.8% for polyethylene vials and 37.3% for glass vials. Therefore, the liquid scintillation was more efficient and sensitive for the measurement of 40 K in aqueous solutions. (Author)

  8. Refining comparative proteomics by spectral counting to account for shared peptides and multiple search engines.

    Science.gov (United States)

    Chen, Yao-Yi; Dasari, Surendra; Ma, Ze-Qiang; Vega-Montoto, Lorenzo J; Li, Ming; Tabb, David L

    2012-09-01

    Spectral counting has become a widely used approach for measuring and comparing protein abundance in label-free shotgun proteomics. However, when analyzing complex samples, the ambiguity of matching between peptides and proteins greatly affects the assessment of peptide and protein inventories, differentiation, and quantification. Meanwhile, the configuration of database searching algorithms that assign peptides to MS/MS spectra may produce different results in comparative proteomic analysis. Here, we present three strategies to improve comparative proteomics through spectral counting. We show that comparing spectral counts for peptide groups rather than for protein groups forestalls problems introduced by shared peptides. We demonstrate the advantage and flexibility of this new method in two datasets. We present four models to combine four popular search engines that lead to significant gains in spectral counting differentiation. Among these models, we demonstrate a powerful vote counting model that scales well for multiple search engines. We also show that semi-tryptic searching outperforms tryptic searching for comparative proteomics. Overall, these techniques considerably improve protein differentiation on the basis of spectral count tables.

  9. The liquid scintillation counting efficiency for 137mCs+137mBa and ''129 I; 'Eficiencias de recuento por centelleo liquido para el Cs+13 mBa y ''129 I

    Energy Technology Data Exchange (ETDEWEB)

    Grau CarLes, A.; Grau Malonda, A.

    1995-07-01

    We compute the liquid scintillation counting efficiency for 137Cs+137mBa and ''129 I taking into account the scintillator chemical composition. We consider the beta transition shape factors for the for bidden beta transitions of these nuclides, and the effects of 137mBa and 129mXe half-lives on the total counting efficiency. (Author) 8 refs.

  10. Preparation of manganese salts of carboxylic acids labelled with ''54Mn and comparison with ''54 MnCl{sub 2} in liquid scintillation counting; Preparacion de sales manganosas de acidos alifaticos monocarboxilicos marcados con ''54 MnCl{sub 2} en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Arcos Merino, J. M. los; Grau Malonda, A.

    1992-07-01

    Procedures for liquid scintillation sample preparation of manganese dimethylbutirate, decanoate and palmitate, labelled with 54 Mn are described. their quenching effect, spectral evolution and counting stability along several weeks are analysed in liquid scintillation measurements with Toluene. HISafe II. PCS, instagel. Dioxane-naphtalene and Toluene-alcohol. For comparison, Inorganic 54 MnCl-2 samples are also studied, resulting in acceptable counting stability but showing greater quenching and signs of little spectral degradation against the organic samples. (Author)

  11. Single crystal and optical ceramic multicomponent garnet scintillators: A comparative study

    International Nuclear Information System (INIS)

    Wu, Yuntao; Luo, Zhaohua; Jiang, Haochuan; Meng, Fang; Koschan, Merry; Melcher, Charles L.

    2015-01-01

    Multicomponent garnet materials can be made in optical ceramic as well as single crystal form due to their cubic crystal structure. In this work, high-quality Gd 3 Ga 3 Al 2 O 12 :0.2 at% Ce (GGAG:Ce) single crystal and (Gd,Lu) 3 Ga 3 Al 2 O 12 :1 at% Ce (GLuGAG:Ce) optical ceramics were fabricated by the Czochralski method and a combination of hot isostatic pressing (HIPing) and annealing treatment, respectively. Under optical and X-ray excitation, the GLuGAG:Ce optical ceramic exhibits a broad Ce 3+ transition emission centered at 550 nm, while the emission peak of the GGAG:Ce single crystal is centered at 540 nm. A self-absorption effect in GLuGAG:Ce optical ceramic results in this red-shift of the Ce 3+ emission peak compared to that in the GGAG:Ce single crystal. The light yield under 662 keV γ-ray excitation was 45,000±2500 photons/MeV and 48,200±2410 photons/MeV for the GGAG:Ce single crystal and GLuGAG:Ce optical ceramic, respectively. An energy resolution of 7.1% for 662 keV γ-rays was achieved in the GLuGAG:Ce optical ceramic with a Hamamatsu R6231 PMT, which is superior to the value of 7.6% for a GGAG:Ce single crystal. Scintillation decay time measurements under 137 Cs irradiation show two exponential decay components of 58 ns (47%) and 504 ns (53%) for the GGAG:Ce single crystal, and 84 ns (76%) and 148 ns (24%) for the GLuGAG:Ce optical ceramic. The afterglow level after X-ray cutoff in the GLuGAG:Ce optical ceramic is at least one order of magnitude lower than in the GGAG:Ce single crystal. - Highlights: • GGAG:Ce single crystal and GLuGAG:Ce optical ceramics were fabricated. • The light yield of both ceramic and crystal G(Lu)GAG:Ce reached the level of 45,000 photons/MeV. • GLuGAG:Ce optical ceramic showed a better energy resolution of 7.1% for 662 keV. • GLuGAG:Ce ceramics exhibited lower afterglow level than that of GGAG:Ce single crystals. • The possible optimization strategies for multicomponent aluminate garnets are discussed

  12. A comparative study of the radiation hardness of plastic scintillators for the upgrade of the Tile Calorimeter of the ATLAS detector

    Science.gov (United States)

    Liao, S.; Erasmus, R.; Jivan, H.; Pelwan, C.; Peters, G.; Sideras-Haddad, E.

    2015-10-01

    The influence of radiation on the light transmittance of plastic scintillators was studied experimentally. The high optical transmittance property of plastic scintillators makes them essential in the effective functioning of the Tile calorimeter of the ATLAS detector at CERN. This significant role played by the scintillators makes this research imperative in the movement towards the upgrade of the tile calorimeter. The radiation damage of polyvinyl toluene (PVT) based plastic scintillators was studied, namely, EJ-200, EJ-208 and EJ-260, all manufactured and provided to us by ELJEN technology. In addition, in order to compare to scintillator brands actually in use at the ATLAS detector currently, two polystyrene (PS) based scintillators and an additional PVT based scintillator were also scrutinized in this study, namely, Dubna, Protvino and Bicron, respectively. All the samples were irradiated using a 6 MeV proton beam at different doses at iThemba LABS Gauteng. The radiation process was planned and mimicked by doing simulations using a SRIM program. In addition, transmission spectra for the irradiated and unirradiated samples of each grade were obtained, observed and analyzed.

  13. Comparative Effectiveness of Two Walking Interventions on Participation, Step Counts, and Health.

    Science.gov (United States)

    Smith-McLallen, Aaron; Heller, Debbie; Vernisi, Kristin; Gulick, Diana; Cruz, Samantha; Snyder, Richard L

    2017-03-01

    To (1) compare the effects of two worksite-based walking interventions on employee participation rates; (2) compare average daily step counts between conditions, and; (3) examine the effects of increases in average daily step counts on biometric and psychologic outcomes. We conducted a cluster-randomized trial in which six employer groups were randomly selected and randomly assigned to condition. Four manufacturing worksites and two office-based worksite served as the setting. A total of 474 employees from six employer groups were included. A standard walking program was compared to an enhanced program that included incentives, feedback, competitive challenges, and monthly wellness workshops. Walking was measured by self-reported daily step counts. Survey measures and biometric screenings were administered at baseline and 3, 6, and 9 months after baseline. Analysis used linear mixed models with repeated measures. During 9 months, participants in the enhanced condition averaged 726 more steps per day compared with those in the standard condition (p women (-2.1 lbs.), and reductions in body mass index (-0.41 men, -0.31 women). Higher step counts were also associated with improvements in mood, having more energy, and higher ratings of overall health. An enhanced walking program significantly increases participation rates and daily step counts, which were associated with weight loss and reductions in body mass index.

  14. Scintillation response of organic and inorganic scintillators

    CERN Document Server

    Papadopoulos, L M

    1999-01-01

    A method to evaluate the scintillation response of organic and inorganic scintillators to different heavy ionizing particles is suggested. A function describing the rate of the energy consumed as fluorescence emission is derived, i.e., the differential response with respect to time. This function is then integrated for each ion and scintillator (anthracene, stilbene and CsI(Tl)) to determine scintillation response. The resulting scintillation responses are compared to the previously reported measured responses. Agreement to within 2.5% is observed when these data are normalized to each other. In addition, conclusions regarding the quenching parameter kB dependence on the type of the particle and the computed values of kB for certain ions are included. (author)

  15. Establishment of methodology for determination of 93Zr in radioactive wastes by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Oliveira, Thiago Cesar de

    2014-01-01

    The zirconium-93 is a long-lived pure β-particle-emitting radionuclide produced from 235 U fission and from neutron activation of the stable isotope 92 Zr and thus occurring as one of the radionuclides found in nuclear reactors. Due to its long half life, 93 Zr is one of the radionuclides of interest for the performance of assessment studies of waste storage or disposal. Measurement of 93 Zr is difficult owing to its trace level concentration and its low activity in nuclear wastes and further because its certified standards are not frequently available. The aim of this work was to develop a selective radiochemical separation methodology for the determination of 93 Zr in nuclear waste and analyze it by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). To set up the radiochemical separation procedure for zirconium, a tracer solution of 95 Zr and its 724 keV γ-ray measurements by γ- spectrometry were used in order to follow the behavior of zirconium during the radiochemical separation. For the LSC technique a 55 Fe solution, which is one of the major interfering measures zirconium, was used to verify the decontamination factor during the separation process. The efficiency detection for 63 Ni was used to determination of 93 Zr activity in the matrices analyzed. The limit of detection of the 0.05 Bq 1 −1 was obtained for 63 Ni standard solutions by using a sample:cocktail ratio of 3:17 mL for Optiphase Hisafe 3 cocktail. For the ICP-MS technique a zirconium stable solution was used to verify the zirconium behavior and recovery during radiochemical separation and a solution of Ba, Co, Eu, Fe, Mn, Nb, Sr and Y was used to verify the decontamination factor during the separation process. A standard solution 93 Nb as isotope for determining the 93 Zr by ICP-MS was used for calibration and analysis. The detection limit of 0.039 ppb was obtained for the standard solution of zirconium. Then, the protocol was applied to low level

  16. Liquid scintillation in medical diagnosis

    International Nuclear Information System (INIS)

    Painter, K.

    1976-01-01

    With the tremendous increase in the application of radioassay, particularly radioimmunoassay, in the clinical laboratory liquid scintillation counting became an indispensable tool in diagnostic medicine. Few publications, however, have concerned themselves with problem areas which occur with the method in the clinical laboratory. The purpose of this presentation is to summarize our experiences with the liquid scintillation technique in the clinical situation

  17. Production low cost plastic scintillator by using commercial polystyrene

    International Nuclear Information System (INIS)

    2011-01-01

    were produced with those determined parameters in 12 June 2008. Plastic blocks prepared were optically and mechanically tested and its response against various radioactive sources was measured. The results regarding the optical, mechanical and detection properties of blocks produced in 10x5x40 cm dimension were compared with commercial LODLUM Scintillator (main component PVT) produced by US in 13x8x120 cm dimensions. It was found that optical and mechanical properties of blocks produced in SANAEM are similar to or better than that of LODLUM. Plastic scintillator produced in SANAEM has shown the same response and counting characteristics that obtained by LODLUM, but proportional to its area and/or volume specifications. This study has shown that plastic scintillators imported can be produced in SANAEM domestically and be used for detection of radioactive materials within the country or border gates.

  18. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  19. The Use of Diethanolamine as a Co2 Absorbent in Was Take the Determination Coral Reef Age in Barrang Lompo Island Spermonde Islands Through Measurements of 14c Activity by Liquid Scintillation Counting (Lsc) Method

    OpenAIRE

    Matande, Jumiati Bunga; Zakir, Muhammad; Noor, Alfian

    2017-01-01

    Research on the use of diethanolamine (DEA) as a CO2 absorbent in was take the determination coral reef age in Barrang Lompo Island, Spermonde Islands through measurements of 14C activity by liquid scintillation Counting method (LSC) was carried our. Coral reef sample of the island Barrang Lompo at coordinates 5 ° 06 '49 " LS 119 ° 25' 20" BT with a dept of 3-4 meters from the sea surface. Coral reefs (coral reef) is an ecosystem that live on the water in the form of limestone formations (CaC...

  20. Scintillator structures

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1978-01-01

    Distributed phosphor scintillator structures providing superior optical coupling to photoelectrically responsive devices together with methods for fabricating said scintillator structures are disclosed. In accordance with one embodiment of the invention relating to scintillator structures, the phosphor is distributed in a 'layered' fashion with certain layers being optically transparent so that the visible wavelength output of the scintillator is better directed to detecting devices. In accordance with another embodiment of the invention relating to scintillator structures, the phosphor is distributed throughout a transparent matrix in a continuous fashion whereby emitted light is more readily transmitted to a photodetector. Methods for fabricating said distributed phosphor scintillator structures are also disclosed. (Auth.)

  1. Framing Electoral Transparency: A comparative analysis of three e-votes counting ceremonies

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Markussen, Randi; Bélanger, Olivier

    2016-01-01

    in the field of e-voting has been proved to be di cult to tackle practically as well as analytically. In this paper we introduce the notion of ‘frames of transparency’ and deploy it to conduct a comparative analysis of three e-votes counting ceremonies in Norway, Estonia and Australia. We ask the question...

  2. Uncovering the method of production and detection of synthetic acetic acid adulteration in vinegar by tandem use of 14C liquid scintillation counting and 13C/12C ratio mass spectrometry

    International Nuclear Information System (INIS)

    Wechner, Stefan; Voropaev, Andrey; Eichinger, Lorenz; Santos, Flora L.; Castaneda, Soledad; Racho, Michael; Pabroa, Preciosa Corazon; Morco, Ryan; Sucgang, Raymond J.

    2010-01-01

    Fraudulent adulteration and or misrepresentation had been a problem for commercial vinegar in the Philippines. Solutions of synthetic acetic acid mixed with colorants and flavour enhancers have been marketed as v inegar . Philippine regulations prohibit the sale of these vinegars produced by non-biogenic means as well as misrepresentation of the fine natural vinegars with cheaper version produced using lower value raw materials. The lack of reliable analytical tools however, has hampered the proper implementation of these laws. In this study, authentic vinegar samples were acquired, which were prepared by natural fermentation of : sugar cane, pineapple juice, and mango juice. Another type of cane vinegar was prepared by fermentation of cane sugar using acetator. Commercial vinegar samples, purchased from major supermarkets in the Philippines, were likewise obtained. Calcium acetate was produced by reaction of distilled vinegar samples with calcium carbonate, and subsequent drying of the resulting solution. Portions of the calcium acetate derived from the samples,were reacted with pyrophosphoric acid in a reflux and the glacial acetic acid was recovered by distillation under reduced pressure. The recovered glacial acetic acid were reconstituted to 90 % v/v. The acetic solutions were mixed with an Optiphase Hisafe Scintillant in vials. The C14 activities of the samples were measured in a 1414 Wallac Scintillation Counter and expressed as disintegrations per gram carbon or dpm/g C. Biogenic samples exhibit 12-15 dpm/g C activities, while synthetic samples show 0-2 dpm/g C activities. The remaining portions of the calcium acetate powder were placed in evacuated glass ampoules containing potassium peroxidisulfate and silver (1) permanganate. The samples inside the ampoules were oxidized to Carbon Dioxide, CO 2 gas, in a furnace. The CO 2 were then purified and bled to an Isotope Ratio mass spectrometer. 1 3C/ 1 2C ratios were determined and compared against a standard

  3. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  4. A sub-boiling distillation method for the preparation of low carbon content water from urine samples for tritium measurement by liquid scintillation counting

    International Nuclear Information System (INIS)

    Nogawa, Norio; Makide, Yoshihiro

    1999-01-01

    A new preparation method was developed for obtaining low carbon content water from urine samples for the measurement of tritium by a liquid scintillation counter. The method uses a simple and convenient subboiling distillation bottle. Many urine samples have been purified by this method and the change of tritium level in a tritium-handling radiation-worker was observed

  5. Scintillation scanner

    International Nuclear Information System (INIS)

    Mehrbrodt, A.W.; Mog, W.F.; Brunnett, C.J.

    1977-01-01

    A scintillation scanner having a visual image producing means coupled through a lost motion connection to the boom which supports the scintillation detector is described. The lost motion connection is adjustable to compensate for such delays as may occur between sensing and recording scintillations. 13 claims, 5 figures

  6. Quantitative determination of 14C(-)-epicatechin and 14C-rutin on the Uncaria plant by a two-step heterogeneous thin-layer chromatographic-liquid scintillation counting procedure

    International Nuclear Information System (INIS)

    Das, N.P.; Law, K.H.

    1987-01-01

    A simple, rapid, precise and relatively inexpensive thin-layer chromatographic method coupled to heterogeneous liquid scintillation counting procedure was used for the quantitation of radioactivity of biologically synthesized ( 14 C) flavonoids and other phenolic plant constituents. The two flavonoids, namely ( 14 C) rutin and ( 14 C) (-) -epicatechin, extracted from the plant Uncaria elliptica Roxb were separated on plastic thin-layer plates coated with silica gel using the two solvent systems : acetonitrile-acetic acid-water (8.5:0.5:1.5) and ethyl acetate-acetic acid-water (3:1:3). The respective spots on the plates that corresponded to the two flavonoids were cut out and eluted with 3 ml aliquots of methanol followed by direct addition of scintillation flour. This method gave 99 +- 2 per cent of the total count indicating the excellent elution procedure. The results were reproducible and showed linearity over the range of 0 - 35000 dpm. The elution efficiency by several other organic solvents were also investigated. (author). 19 refs., 4 tables

  7. Comparative study of transparent ceramic and single crystal Ce doped LuAG scintillators

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Fujimoto, Yutaka; Yokota, Yuui; Kamada, Kei; Yanagida, Satoko; Yoshikawa, Akira; Yagi, Hideki; Yanagitani, Takagimi

    2011-01-01

    Transparent ceramic Ce 0.5% doped Lu 3 Al 5 O 12 (LuAG) scintillator grown by the sintering method and single crystalline Ce doped LuAG grown by the Czochralski method are prepared. They are cut to the physical dimensions 4 × 4 × 2 mm 3 . Their transmittance and radio luminescence spectra are evaluated. They are both transmissive in wavelength longer than 500 nm and intense Ce 3+ 5d–4f emission appears around 520 nm. When 137 Cs γ-ray is irradiated, 662 keV photo-absorption peaks are clearly observed in each sample. The transparent ceramic one shows higher light yield than that of the single crystalline one. The absolute light yield of the ceramic sample is turned out to be 14800 ± 1500 ph/MeV. The decay time constants are evaluated under pulse X-ray excitation. The main component of the decay time of ceramic and single crystalline one are determined as 37 and 46 ns, respectively.

  8. Comparing distribution models for small samples of overdispersed counts of freshwater fish

    Science.gov (United States)

    Vaudor, Lise; Lamouroux, Nicolas; Olivier, Jean-Michel

    2011-05-01

    The study of species abundance often relies on repeated abundance counts whose number is limited by logistic or financial constraints. The distribution of abundance counts is generally right-skewed (i.e. with many zeros and few high values) and needs to be modelled for statistical inference. We used an extensive dataset involving about 100,000 fish individuals of 12 freshwater fish species collected in electrofishing points (7 m 2) during 350 field surveys made in 25 stream sites, in order to compare the performance and the generality of four distribution models of counts (Poisson, negative binomial and their zero-inflated counterparts). The negative binomial distribution was the best model (Bayesian Information Criterion) for 58% of the samples (species-survey combinations) and was suitable for a variety of life histories, habitat, and sample characteristics. The performance of the models was closely related to samples' statistics such as total abundance and variance. Finally, we illustrated the consequences of a distribution assumption by calculating confidence intervals around the mean abundance, either based on the most suitable distribution assumption or on an asymptotical, distribution-free (Student's) method. Student's method generally corresponded to narrower confidence intervals, especially when there were few (≤3) non-null counts in the samples.

  9. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  10. Advantages of GSO Scintillator in Imaging and Law Level Gamma-ray Spectroscopy

    CERN Document Server

    Sharaf, J

    2002-01-01

    The single GSO crystal is an excellent scintillation material featuring a high light yield and short decay time for gamma-ray detection. Its performance characteristics were investigated and directly compared to those of BGO. For this purpose, the two scintillators are cut into small crystals of approximately 4*4*10 mm sup 3 and mounted on a PMT. Energy resolution, detection efficiency and counting precision have been measured for various photon energies. In addition to this spectroscopic characterization, the imaging performance of GSO was studied using a scanning rig. The modulation transfer function was calculated and the spatial resolution evaluated by measurements of the detector's point spread function. It is shown that there exists some source intensity for which the two scintillators yield identical precision for identical count time. Below this intensity, the GSO is superior to the BGO detector. The presented properties of GSO suggest potential applications of this scintillator in gamma-ray spectrosc...

  11. Comparison of analysis techniques by liquid scintillation and Cerenkov Effect for {sup 40}K quantification in aqueous samples; Comparacion de las tecnicas de analisis por centelleo liquido y efecto Cerenkov para la cuantificacion {sup 40}K en muestras acuosas

    Energy Technology Data Exchange (ETDEWEB)

    Miranda C, L.; Davila R, J. I.; Lopez del R, H.; Mireles G, F., E-mail: lilimica20@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-09-15

    In this work the counting by liquid scintillation and Cerenkov Effect to quantify {sup 40}K in aqueous samples was used. The performance of both techniques was studied by comparing the response of three commercial liquid scintillation OptiPhase HiSafe 3, Ultima Gold Ab and OptiPhase TriSafe, the vial type and presentation conditions of the sample for counting. In liquid scintillation, the ability to form homogeneous mixtures depended on the ionic strength of the aqueous solutions. The scintillator OptiPhase HiSafe 3 showed a greater charge capacity for solutions with high ionic strength (<3.4), while the scintillator OptiSafe TriSafe no form homogeneous mixtures for solutions of ionic strength higher than 0.3. Counting efficiencies for different proportions of sample and scintillator near 100% for the scintillators OptiSafe HiSafe 3 and Ultima Gold Ab were obtained. In the counting by Cerenkov Effect, the efficiency and sensitivity depended of the vial type; polyethylene vials were more suitable for counting that the glass vials. The sample volume had not significant effect on counting efficiency, obtaining an average value of 44.8% for polyethylene vials and 37.3% for glass vials. Therefore, the liquid scintillation was more efficient and sensitive for the measurement of {sup 40}K in aqueous solutions. (Author)

  12. Comparison of two types of scintillation probe for moisture density gauge

    International Nuclear Information System (INIS)

    Machaj, B.

    1974-01-01

    Investigations of pulse shape discrimination scintillation probe, and amplitude discrimination probe as a detector for moisutre density gauge have been carried out. It was found that sandwich scintillator consisting of NE-421 + NE-102A was the best for pulse shape discrimination probe for thermal neutrons and gamma radiation detection. Similarly LiJ(Eu) crystal was the best for amplitude discrimination probe. The amplitude discrimination probe with LiJ(Eu) comparing to pulse shape discrimination probe with sandwich scintillator, provides approximately two times higher thermal neutron detection efficiency and higher count rate stability. It is considered therefore more suitable as the detector for moisture density gauge. (author)

  13. Manual calibration of liquid scintillation counter using the channel ratio technique

    International Nuclear Information System (INIS)

    Moussa, H.M.; Townsend, L.; Miller, L.F.

    1999-01-01

    The objectives of this activity are to introduce students to liquid scintillation counting and to calibrate the counter using the sample channel ratio technique. This is accomplished by using quenched standards set for 14 C and tritium ( 3 H) to generate a quench correction curve for the scintillation solution. It is a good method for students to gain a detailed understanding of issues important to manual calibration of a liquid scintillation counter, and results can be compared with a built-in automatic method

  14. Scintillation Counters

    Science.gov (United States)

    Bell, Zane W.

    Scintillators find wide use in radiation detection as the detecting medium for gamma/X-rays, and charged and neutral particles. Since the first notice in 1895 by Roentgen of the production of light by X-rays on a barium platinocyanide screen, and Thomas Edison's work over the following 2 years resulting in the discovery of calcium tungstate as a superior fluoroscopy screen, much research and experimentation have been undertaken to discover and elucidate the properties of new scintillators. Scintillators with high density and high atomic number are prized for the detection of gamma rays above 1 MeV; lower atomic number, lower-density materials find use for detecting beta particles and heavy charged particles; hydrogenous scintillators find use in fast-neutron detection; and boron-, lithium-, and gadolinium-containing scintillators are used for slow-neutron detection. This chapter provides the practitioner with an overview of the general characteristics of scintillators, including the variation of probability of interaction with density and atomic number, the characteristics of the light pulse, a list and characteristics of commonly available scintillators and their approximate cost, and recommendations regarding the choice of material for a few specific applications. This chapter does not pretend to present an exhaustive list of scintillators and applications.

  15. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  16. The Scintillation Counting of Calcium-45; Comptage du Calcium-45 au Moyen d'un Scintillateur; Izmerenie aktivnosti Kal'tsiya-45 stsintillyatsionnym metodom; Determinacion del Calcio-45 Mediante Contadores de Centelleo

    Energy Technology Data Exchange (ETDEWEB)

    Carr, T. E.F.; Parsons, B. J. [Medical Research Council, Radiobiological Research Unit, Harwell (United Kingdom)

    1965-10-15

    A review is made of some of the methods for the assay of {sup 45}Ca in biological materials. Experience gained from the assay of {sup 45}Ca in such materials, using a liquid scintillation technique previously published by the authors, is reported. Difficulties were found with certain samples because of the presence of relatively large amounts of iron. The quenching of the scintillator due to this iron, and methods for overcoming it are discussed. Results are given of the use of external gamma-ray sources as standards and as a means of estimating quenching effects in certain samples. Though not entirely satisfactory for the measurement of quenching, their use as a standard for checking counter performance is recommended. A comparison is given of the methods, including liquid and plastic scintillation counting of {sup 45}Ca covering the following aspects: (a) efficiency, (b) background, (c) ease and speed of sample preparation, (d) use of standards and reproducibility, and (e) stable calcium capacity. Recommendations are made as to which technique is most suitable under given circumstances. (author) [French] Les auteurs examinent plusieurs methodes de dosage de {sup 45}Ca contenu dans des substances biologiques. Ils decrivent les resultats qu'ils ont obtenus precedemment en analysant, au' moyen d'un scintillateur liquide, le {sup 45}Ca contenu dans ces substances. Certains echantillons ont cause des difficultes, car ils contenaient des quantites de fer assez importantes. Le memoire fait etat de l'extinction du scintillateur provoquee par ces quantites de fer et discute les methodes qui permettent d'y remedier. Les auteurs donnent les resultats obtenus avec des sources gamma exterieures utilisees comme etalons qui permettent par ailleurs d'evaluer les effets d'extinction dans certains echantillons. Bien que ces sources ne soient pas entierement satisfaisantes pour mesurer l'extinction, ils recommandent de les utiliser comme etalons pour controler la performance du

  17. Scintillation camera

    International Nuclear Information System (INIS)

    Zioni, J.; Klein, Y.; Inbar, D.

    1975-01-01

    The scintillation camera is to make pictures of the density distribution of radiation fields created by the injection or administration radioactive medicaments into the body of the patient. It contains a scintillation crystal, several photomultipliers and computer circuits to obtain an analytical function at the exits of the photomultiplier which is dependent on the position of the scintillations at the time in the crystal. The scintillation crystal is flat and spatially corresponds to the production site of radiation. The photomultipliers form a pattern whose basic form consists of at least three photomultipliers. They are assigned to at least two crossing parallel series groups where a vertical running reference axis in the crystal plane belongs to each series group. The computer circuits are each assigned to a reference axis. Each series of a series group assigned to one of the reference axes in the computer circuit has an adder to produce a scintillation dependent series signal. Furthermore, the projection of the scintillation on this reference axis is calculated. A series signal is used for this which originates from a series chosen from two neighbouring photomultiplier series of this group. The scintillation must have appeared between these chosen series. They are termed as basic series. The photomultiplier can be arranged hexagonally or rectangularly. (GG/LH) [de

  18. Calculating concentration of inhaled radiolabeled particles from external gamma counting: External counting efficiency and attenuation coefficient of thorax

    International Nuclear Information System (INIS)

    Langenback, E.G.; Foster, W.M.; Bergofsky, E.H.

    1989-01-01

    We determined the overall external counting efficiency of radiolabeled particles deposited in the sheep lung. This efficiency permits the noninvasive calculation of the number of particles and microcuries from gamma-scintillation lung images of the live sheep. Additionally, we have calculated the attenuation of gamma radiation (120 keV) by the posterior chest wall and the gamma-scintillation camera collection efficiency of radiation emitted from the lung. Four methods were employed in our experiments: (1) by light microscopic counting of discrete carbonized polystyrene particles with a count median diameter (CMD) of 2.85 microns and tagged with cobalt-57, we delineated a linear relationship between the number of particles and the emitted counts per minute (cpm) detected by well scintillation counting; (2) from this conversion relationship we determined the number of particles inhaled and deposited in the lungs by scintillation counting fragments of dissected lung at autopsy; (3) we defined a linear association between the number of particles or microcuries contained in the lung and the emitted radiation as cpm detected by a gamma scintillation camera in the live sheep prior to autopsy; and (4) we compared the emitted radiation from the lungs of the live sheep to that of whole excised lungs in order to calculate the attenuation coefficient (ac) of the chest wall. The mean external counting efficiency was 4.00 X 10(4) particles/cpm (5.1 X 10(-3) microCi/cpm), the camera collection efficiency was 1 cpm/10(4) disintegrations per minute (dpm), and the ac had a mean of 0.178/cm. The external counting efficiency remained relatively constant over a range of particles and microcuries, permitting a more general use of this ratio to estimate number of particles or microcuries depositing after inhalation in a large mammalian lung if a similarly collimated gamma camera system is used

  19. Antibiotic Resistances in Livestock: A Comparative Approach to Identify an Appropriate Regression Model for Count Data

    Directory of Open Access Journals (Sweden)

    Anke Hüls

    2017-05-01

    Full Text Available Antimicrobial resistance in livestock is a matter of general concern. To develop hygiene measures and methods for resistance prevention and control, epidemiological studies on a population level are needed to detect factors associated with antimicrobial resistance in livestock holdings. In general, regression models are used to describe these relationships between environmental factors and resistance outcome. Besides the study design, the correlation structures of the different outcomes of antibiotic resistance and structural zero measurements on the resistance outcome as well as on the exposure side are challenges for the epidemiological model building process. The use of appropriate regression models that acknowledge these complexities is essential to assure valid epidemiological interpretations. The aims of this paper are (i to explain the model building process comparing several competing models for count data (negative binomial model, quasi-Poisson model, zero-inflated model, and hurdle model and (ii to compare these models using data from a cross-sectional study on antibiotic resistance in animal husbandry. These goals are essential to evaluate which model is most suitable to identify potential prevention measures. The dataset used as an example in our analyses was generated initially to study the prevalence and associated factors for the appearance of cefotaxime-resistant Escherichia coli in 48 German fattening pig farms. For each farm, the outcome was the count of samples with resistant bacteria. There was almost no overdispersion and only moderate evidence of excess zeros in the data. Our analyses show that it is essential to evaluate regression models in studies analyzing the relationship between environmental factors and antibiotic resistances in livestock. After model comparison based on evaluation of model predictions, Akaike information criterion, and Pearson residuals, here the hurdle model was judged to be the most appropriate

  20. Mass counting of radioactivity samples

    International Nuclear Information System (INIS)

    Oesterlin, D.L.; Obrycki, R.F.

    1977-01-01

    A method and apparatus for concurrently counting a plurality of radioactive samples is claimed. The position sensitive circuitry of a scintillation camera is employed to sort electrical pulses resulting from scintillations according to the geometrical locations of scintillations causing those pulses. A scintillation means, in the form of a scintillating crystal material or a liquid scintillator, is positioned proximate to an array of radioactive samples. Improvement in the accuracy of pulse classification may be obtained by employing collimating means. If a plurality of scintillation crystals are employed to measure the iodine-125 content of samples, a method and means are provided for correcting for variations in crystal light transmission properties, sample volume, and sample container radiation absorption. 2 claims, 7 drawing figures

  1. On the stability of performance of NaI(Tl) scintillation spectrometer with FEhU-49 photomultiplier at high counting rates

    International Nuclear Information System (INIS)

    Belousov, A.S.; Vazdik, Ya.A.; Malinovskij, E.N.; Rusakov, S.V.; Solov'ev, Yu.V.; Fomenko, A.M.; Sharejko, P.N.

    1986-01-01

    The dependence of instability in NaI(Tl)-spectrometer characteristics on the instability of photomultiplier (PM), the multiplication factor of which grows with an increase in counting rate, is determined. A simple way to stabilize PM gain factor with an accuracy up to 1.7% is suggested, which consists in stabilization of voltage in two terminal dynodes of PM and photocathode illumination by an auxillary light source

  2. Plastic scintillator

    International Nuclear Information System (INIS)

    Andreeshchev, E.A.; Kilin, S.F.; Kavyrzina, K.A.

    1978-01-01

    A plastic scintillator for ionizing radiation detectors with high time resolution is suggested. To decrease the scintillation pulse width and to maintain a high light yield, the 4 1 , 4 5 -dibromo-2 1 , 2 5 , 5 1 , 5 5 -tetramethyl-n-quinquiphenyl (Br 2 Me 4 Ph) in combination with n-terphenyl (Ph 3 ) or 2, 5-diphenyloxadiazol-1, 3, 4 (PPD) is used as a luminescent addition. Taking into consideration the results of a special study, it is shown, that the following ratio of ingradients is the optimum one: 3-4 mass% Ph 3 or 4-7 mas% PPD + 2-5 mass% Br 2 Me 4 Ph + + polymeric base. The suggested scintillator on the basis of polystyrene has the light yield of 0.23-0.26 arbitrary units and the scintillation pulse duration at half-height is 0.74-0.84 ns

  3. Enhanced counting efficiency of Cerenkov radiation from bismuth-210

    International Nuclear Information System (INIS)

    Peck, G.A.; Smith, J.D.

    1998-01-01

    This paper describes the measurement of 210 Bi by Cerenkov counting in a commercial liquid scintillation counter. The counting efficiency in water is 0.17 counts per second per Becquerel (17%). When the enhancers Triton X-100 (15% v/v) and sodium salicylate (1% m/v) are added to the solution the counting efficiency for 210 Bi increases from 17% to 75%. The 210 Po daughter of 210 Bi causes interference of 0.85 counts per second per Becquerel in the presence of the enhancers but not in water. When 210 Bi and 210 Po are present in secular equilibrium the total counting efficiency is 160%. When 210 Bi and 210 Po are not in secular equilibrium the 210 Po can be removed immediately before counting by plating onto silver foil. The use of the enhancers gives a substantial increase in counting efficiency compared to counting in water. Compared with solutions used in liquid scintillation counting the enhancer solution is inexpensive and can be disposed of without environmental hazard. (author)

  4. Evaluation of the uncertainty for the efficiency curve determination of 210Pb by liquid scintillation

    International Nuclear Information System (INIS)

    Sampaio, C.S.; Sousa, W.O.; Dantas, B.M.

    2014-01-01

    Methodologies for the evaluation of uncertainties associated with the determination of the efficiency curve of 210 Pb by liquid scintillation counting (LSC) are presented. No statistical difference were found when compared the uncertainties of the curves that represented the counting net before and after the secular equilibrium between 210 Pb and 210 Bi, nether when compared the curves when counting only 210 Pb and the curve with the total count of 210 Pb and 210 Bi, for the same time interval after precipitation. (author)

  5. Comparative study of Tm-doped and Tm-Sc co-doped Lu3Al5O12 scintillator

    International Nuclear Information System (INIS)

    Sugiyama, Makoto; Yanagida, Takayuki; Fujimoto, Yutaka

    2014-01-01

    The crystals of Tm doped and Tm-Sc co-doped Lu 3 Al 5 O 12 (LuAG) grown by the floating zone (FZ) method were examined for their optical and scintillation properties. In transmittance spectra, strong absorption lines due to Tm 3+ 4f–4f transitions were observed. X-ray excited radioluminescence spectra were measured and broad and sharp emission peaks were detected. The former one was attributed to Sc 3+ and the latter one was due to Tm 3+ 4f–4f transitions. Scintillation yield enhancement due to Sc co-doping was observed by means of 137 Cs pulse height spectra. Scintillation decay times were several tens of μs under pulse X-ray excitation. - Highlights: • LuAG:Tm and LuAG:Tm, Sc single crystals have been grown by the FZ method. • Tm 3+ 4f–4f absorption has been observed in transmittance spectra. • Scintillation yield of Tm-doped LuAG has been enhanced by Sc co-doping

  6. Scintillation counter based radiation dosimeter

    International Nuclear Information System (INIS)

    Shin, Jeong Hyun

    2009-02-01

    The average human exposure per year is about 240mrem which is come from Radon and human body and terrestrial and cosmic radiation and man-made source. Specially radiation exposure through air from environmental radiation sources is 80mrem/yr(= 0.01mR/hr) which come from Terrestrial and cosmic radiation. Radiation dose is defined as energy deposit/mass. There are two major methods to detect radiation. First method is the energy integration using Air equivalent material like GM counter wall material. Second method is the spectrum to dose conversion method using NaI(Tl), HPGe. These two methods are using generally to detect radiation. But these methods are expensive. So we need new radiation detection method. The research purpose is the development of economical environmental radiation dosimeter. This system consists of Plastic/Inorganic scintillator and Si photo-diode based detector and counting based circuitry. So count rate(cps) can be convert to air exposure rate(R/hr). There are three major advantages in this system. First advantages is no high voltage power supply like GM counter. Second advantage is simple electronics. Simple electronics system can be achieved by Air-equivalent scintillation detector with Al filter for the same detection efficiency vs E curve. From former two advantages, we can know the most important advantages of the this system. Third advantage is economical system. The price of typical GM counter is about $1000. But the price of our system is below $100 because of plastic scintillator and simple electronics. The role of scintillation material is emitting scintillation which is the flash of light produced in certain materials when they absorb ionizing radiation. Plastic scintillator is organic scintillator which is kind of hydrocarbons. The special point are cheap price, large size production(∼ton), moderate light output, fast light emission(ns). And the role of Al filter is equalizing counting efficiency of air and scintillator for

  7. Comparative Analysis between LDR and HDR Images for Automatic Fruit Recognition and Counting

    Directory of Open Access Journals (Sweden)

    Tatiana M. Pinho

    2017-01-01

    Full Text Available Precision agriculture is gaining an increasing interest in the current farming paradigm. This new production concept relies on the use of information technology (IT to provide a control and supervising structure that can lead to better management policies. In this framework, imaging techniques that provide visual information over the farming area play an important role in production status monitoring. As such, accurate representation of the gathered production images is a major concern, especially if those images are used in detection and classification tasks. Real scenes, observed in natural environment, present high dynamic ranges that cannot be represented by the common LDR (Low Dynamic Range devices. However, this issue can be handled by High Dynamic Range (HDR images since they have the ability to store luminance information similarly to the human visual system. In order to prove their advantage in image processing, a comparative analysis between LDR and HDR images, for fruits detection and counting, was carried out. The obtained results show that the use of HDR images improves the detection performance to more than 30% when compared to LDR.

  8. A directional gamma-ray detector based on scintillator plates

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, D., E-mail: hanna@physics.mcgill.ca; Sagnières, L.; Boyle, P.J.; MacLeod, A.M.L.

    2015-10-11

    A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising a plate of CsI(Tl) scintillator coupled to a photomultiplier tube, can locate a point source of gamma rays with degree-scale precision by comparing the count rates in the different modules. Sensitivity to uniform environmental background is minimal.

  9. The study of vial and cocktail for tritium radioactivity analysis of rain water by liquid scintillation counter

    International Nuclear Information System (INIS)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Lee, Man Woo; Jeong, Dong Hyeok; Yang, Kwang Mo; Kang, Yeong Rok; Nam, Sang Hee

    2015-01-01

    Even though the current method for tritium (3H) analysis is routine, for the case of the low level of tritium in the environment, special conditions have to be fulfilled in order to obtain accurate and reliable tritium measurements. There are very little comparative data concerning commercial scintillating cocktails. The best cocktails for measuring tritium are those based on benzene derived solvent, and the worse cocktails are those which have complex chemical composition or contain too small concentration of scintillators. The aim of study was to investigate various vials and cocktails by comparison with the combination of few different scintillation cocktails and vials in our routine measurements according to count, efficiency, and the figure of merit (FOM). The comparison of three types of vials with scintillation cocktails for tritium activity analysis of rain water shows that glass vials have higher count rates and HiSafe 3 cocktails have lower FOM

  10. Restaurants With Calories Displayed On Menus Had Lower Calorie Counts Compared To Restaurants Without Such Labels.

    Science.gov (United States)

    Bleich, Sara N; Wolfson, Julia A; Jarlenski, Marian P; Block, Jason P

    2015-11-01

    Beginning in December 2016, calorie labeling on menus will be mandatory for US chain restaurants and many other establishments that serve food, such as ice cream shops and movie theaters. But before the federal mandate kicks in, several large chain restaurants have begun to voluntarily display information about the calories in the items on their menus. This increased transparency may be associated with lower overall calorie content of offered items. This study used data for the period 2012-14 from the MenuStat project, a data set of menu items at sixty-six of the largest US restaurant chains. We compared differences in calorie counts of food items between restaurants that voluntarily implemented national menu labeling and those that did not. We found that the mean per item calorie content in all years was lower for restaurants that voluntarily posted information about calories (the differences were 139 calories in 2012, 136 in 2013, and 139 in 2014). New menu items introduced in 2013 and 2014 showed a similar pattern. Calorie labeling may have important effects on the food served in restaurants by compelling the introduction of lower-calorie items. Project HOPE—The People-to-People Health Foundation, Inc.

  11. Restaurants With Calories Displayed On Menus Had Lower Calorie Counts Compared To Restaurants Without Such Labels

    Science.gov (United States)

    Bleich, Sara N.; Wolfson, Julia A.; Jarlenski, Marian P.; Block, Jason P.

    2016-01-01

    Beginning in December 2016, calorie labeling on menus will be mandatory for US chain restaurants and many other establishments that serve food, such as ice cream shops and movie theaters. But before the federal mandate kicks in, several large chain restaurants have begun to voluntarily display information about the calories in the items on their menus. This increased transparency may be associated with lower overall calorie content of offered items. This study used data for the period 2012–14 from the MenuStat project, a data set of menu items at sixty-six of the largest US restaurant chains. We compared differences in calorie counts of food items between restaurants that voluntarily implemented national menu labeling and those that did not. We found that the mean per item calorie content in all years was lower for restaurants that voluntarily posted information about calories (the differences were 139 calories in 2012, 136 in 2013, and 139 in 2014). New menu items introduced in 2013 and 2014 showed a similar pattern. Calorie labeling may have important effects on the food served in restaurants by compelling the introduction of lower-calorie items. PMID:26526245

  12. Nucleon fragmentation in pn and pp interactions compared with quark counting rules

    Energy Technology Data Exchange (ETDEWEB)

    Bakken, V.; Breivik, F.O.; Jacobsen, T. (Oslo Univ. (Norway). Fysisk Inst.)

    1981-11-01

    New data on longitudinal invariant structure functions Edsigma/dx for several low-psub(T) fragmentation processes in pn interactions at 19 GeV/c are presented, based on a bubble chamber study of pd collisions. The single-particle processes n..--> pi../sup + -/, p..--> pi../sup + -/, is investigated n..-->..p, n/p..-->..rho/sup 0/, p..-->..psub(inel) and p..--> delta../sup + +/(1232) as well as the dipion processes n..--> pi../sup -/..pi../sup -/, n..--> pi../sup +/..pi../sup +/, n..--> pi../sup +/..pi../sup -/ and p..--> pi../sup -/..pi../sup -/. Data of the authors on pp collisions at 19 GeV/c regarding p..--> pi../sup -/, p..-->..K/sup 0/sub(S) and p..--> lambda.. have also been considered. The structure functions of these processes are, in the fragmentation region, adequately fitted by Edsigma/dx ..cap alpha.. (1-xi such that sup(n). imilar fits are made to published data on hadron-neutron interactionseractions and ISR data on pp..-->..n+X. The results are compared with earlier data on proton fragmentation. The values of n show no energy dependence. They are in qualitative agreement with the recently formulated quark counting rules, but some quantitative disagreements are observed.

  13. Nucleon fragmentation in pn and pp interactions compared with quark counting rules

    Energy Technology Data Exchange (ETDEWEB)

    Bakken, V.; Breivik, F.O.; Jacobsen, T. (Oslo Univ. (Norway). Fysisk Inst.)

    1981-11-01

    New data on longitudinal invariant structure functions E dsigma/dx for several low-psub(T) fragmentation processes in pn interactions at 19 GeV/c are presented, based on a bubble chamber study of pd collisions. We investigate the single-particle processes n..--> pi..sup(+-), p..--> pi..sup(+-), n..-->..p, n/p..-->..p/sup 0/, p..-->..psub(i)sub(n)sub(e)sub(l) and p..--> delta../sup + +/(1232) as well as the dipion processes n..--> pi..-..pi..-, n..--> pi..+..pi..+, n..--> pi..+..pi..- and p..--> pi..-..pi..-. We have also considered our data on pp collisions at 19 GeV/c regarding p..--> pi..-, p..-->..Ksub(s)/sup 0/ and p..--> lambda... The structure functions of these processes are, in the fragmentation region, adequately fitted by Edsigma/dx approx. equal to (1- vertical stroke z vertical stroke )sup(n). Similar fits are made to published data on hadron-neutron interactions and ISR data on pp..-->..n+X. The results are compared with earlier data on proton fragmentation. The values of n show no energy dependence. They are in qualitative agreement with the recently formulated quark counting rules, but some quantitative disagreements are observed.

  14. Paraffin scintillator for radioassay of solid support samples

    International Nuclear Information System (INIS)

    Fujii, Haruo; Takiue, Makoto

    1989-01-01

    A new paraffin scintillator used for solid support sample counting has been proposed, and its composition and various characteristics are described. The solid support sample treated with this scintillator can be easily handled because of rigid sample conditions. This technique provides great advantages such as the elimination of a large volume of scintillator and little radioactive waste material by using an economical polyethylene bag instead of the conventional counting vial. (author)

  15. Liquid scintillation alpha spectrometry techniques

    International Nuclear Information System (INIS)

    McKlveen, J.W.; McDowell, W.J.

    1984-01-01

    Accurate, quantitative determinations of alpha emitting nuclides by conventional plate counting methods are difficult, because of sample self-absorption problems in counting and because of non-reproducible losses in conventional sample separation methods. Liquid scintillation alpha spectrometry offers an attractive alternative with no sample self-absorption or geometry problems and with 100% counting efficiency. Sample preparation may include extraction of the alpha emitter of interest by a specific organic phase-soluble compound directly into the liquid scintillation counting medium. Detection electronics use energy and pulse-shape discrimination, to yield alpha spectra without beta and gamma background interference. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium and colonium assay. Possibilities for a large number of other applications exist. Accuracy and reproducibility are typically in the 1% range. Backgrounds of the order of 0.01 cpm are readily achievable. The paper will present an overview of liquid scintillation alpha counting techniques and some of the results achieved for specific applications. (orig.)

  16. Liquid scintillation solutions

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The liquid scintillation solution described includes a mixture of: a liquid scintillation solvent, a primary scintillation solute, a secondary scintillation solute, a variety of appreciably different surfactants, and a dissolving and transparency agent. The dissolving and transparency agent is tetrahydrofuran, a cyclic ether. The scintillation solvent is toluene. The primary scintillation solute is PPO, and the secondary scintillation solute is dimethyl POPOP. The variety of appreciably different surfactants is composed of isooctylphenol-polyethoxyethanol and sodium dihexyl sulphosuccinate [fr

  17. Scintillating camera

    International Nuclear Information System (INIS)

    Vlasbloem, H.

    1976-01-01

    The invention relates to a scintillating camera and in particular to an apparatus for determining the position coordinates of a light pulse emitting point on the anode of an image intensifier tube which forms part of a scintillating camera, comprising at least three photomultipliers which are positioned to receive light emitted by the anode screen on their photocathodes, circuit means for processing the output voltages of the photomultipliers to derive voltages that are representative of the position coordinates; a pulse-height discriminator circuit adapted to be fed with the sum voltage of the output voltages of the photomultipliers for gating the output of the processing circuit when the amplitude of the sum voltage of the output voltages of the photomultipliers lies in a predetermined amplitude range, and means for compensating the distortion introduced in the image on the anode screen

  18. Scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1979-01-01

    A scintillator structure comprises at least one layer of transparent fused quartz with a phosphor coating on one or both sides adjacent to at least one transparent layer of epoxy resin which directs light from the phosphor to a detector. The phosphor layer may be formed from a powder optionally with a binder, a single crystal or a melt, or by evaporation or sintering. A plurality of multiple layers may be used or the structure tilted for greater absorption. The structure may be surrounded by another such structure optionally operating in cascade with the first. Many phosphors are specified. A scintillator structure comprises phosphor particles dispersed in epoxy resin or copoly imide-silicone and cast in a multi-compartment box with long sides transparent to X-rays and dividers opaque to X-rays. (UK)

  19. Comparative study of scintillation properties of RE doped NaPO3-Al(PO3)3 glasses

    International Nuclear Information System (INIS)

    Kuro, Tomoaki; Yanagida, Takayuki; Okada, Go; Fujimoto, Yutaka; Masai, Hirokazu

    2015-01-01

    We systematically investigated photoluminescence (PL), scintillation and dosimeter properties of rare-earth (RE) doped NaPO 3 -Al(PO 3 ) 3 (NAP) glasses. Ag-doped NAP glass is widely used for individual radiation dosimeter, however, there have been few reports on studies about NAP glasses when RE ions are doped as the luminescence center. The NAP glasses doped with 0.3 wt% RE (La∼Yb) were prepared by the conventional melt-quenching method. PL decay time and scintillation decay time profiles showed fast (ns) and slow (μs or ms) components: the fast components were from several tens to 100 ns due to the host emission or 5d-4f transition emission, and the slow component from few μs to few ms was caused by 4f-4f transition emission of RE 3+ . Thermally stimulated luminescence (TSL) was evaluated as a dosimeter property, and glow peaks appeared around 400degC in all the samples. The TSL dose response function was examined in the dose range from 10 mGy to 10 Gy, and good linearity was observed in RE-doped NAP glasses. (author)

  20. Scintillating fibres

    International Nuclear Information System (INIS)

    Nahnhauer, R.

    1990-01-01

    In the search for new detector techniques, scintillating fibre technology has already gained a firm foothold, and is a strong contender for the extreme experimental conditions of tomorrow's machines. Organized by a group from the Institute of High Energy Physics, Berlin-Zeuthen, a workshop held from 3-5 September in the nearby village of Blossin brought together experts from East and West, and from science and industry

  1. Scintillating fibres

    Energy Technology Data Exchange (ETDEWEB)

    Nahnhauer, R. [IHEP Zeuthen (Germany)

    1990-11-15

    In the search for new detector techniques, scintillating fibre technology has already gained a firm foothold, and is a strong contender for the extreme experimental conditions of tomorrow's machines. Organized by a group from the Institute of High Energy Physics, Berlin-Zeuthen, a workshop held from 3-5 September in the nearby village of Blossin brought together experts from East and West, and from science and industry.

  2. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples

    International Nuclear Information System (INIS)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L.

    2014-10-01

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  3. A new plastic scintillator with large Stokes shift

    International Nuclear Information System (INIS)

    Destruel, P.; Taufer, M.

    1989-01-01

    We have developed a new plastic scintillator with the novel characteristic of highly localized light emission; scintillation and wavelength shifting take place within a few tens of micrometers of the primary ionization. The new scintillator consists of a scintillating polymer base [polyvinyl toluene (PVT) or polystyrene (PS)] doped with a single wavelength shifter, 1-phenyl-3-mesityl-2-pyrazoline (PMP), which has an exceptionally large Stokes shift and therefore a comparatively small self-absorption of its emitted light. In other characteristics (e.g. scintillation efficiency and decay time) the performance of the new scintillator is similar to a good quality commercial plastic scintillator such as NE110. (orig.)

  4. Sub-nanosecond plastic scintillators

    International Nuclear Information System (INIS)

    Lyons, P.B.; Caldwell, S.E.; Hocker, L.P.; Crandall, D.G.; Zagarino, P.A.; Cheng, J.; Tirsell, G.; Hurlbut, C.R.

    1977-01-01

    Quenched plastic scintillators have been developed that yield much faster short decay components and greatly reduced long decay components compared to conventional plastic scintillators. The plastics are produced through the addition of selected quench agents to NE111 plastic scintillator that result in reduced total light output. Eight different agents have been studied. Benzophenone and piperidine are two of the most effective quench agents. Data are presented both for short and long decay components. The plastics are expected to make significant contributions in areas of plasma diagnostics

  5. Sub-nanosecond plastic scintillators

    International Nuclear Information System (INIS)

    Lyons, P.B.; Caldwell, S.E.; Hocker, L.P.; Crandall, D.G.; Zagarino, P.A.; Cheng, J.; Tirsell, G.; Hurlbut, C.R.

    1976-01-01

    Quenched plastic scintillators have been developed that yield much faster short decay components and greatly reduced long decay components compared to conventional plastic scintillators. The plastics are produced through the addition of selected quench agents to NE111 plastic scintillator that result in reduced total light output. Eight different agents have been studied. Benzophenone and piperidine are two of the most effective quench agents. Data are presented both for short and long decay components. The plastics are expected to make significant contributions in areas of plasma diagnostics

  6. Comparative study of optical and scintillation properties of YVO4, (Lu0.5Y0.5)VO4, and LuVO4 single crystals

    International Nuclear Information System (INIS)

    Fujimoto, Yutaka; Yanagida, Takayuki; Yokota, Yuui; Chani, Valery; Kochurikhin, Vladimir V.; Yoshikawa, Akira

    2011-01-01

    Optical and scintillation properties of YVO 4 , (Lu 0.5 Y 0.5 )VO 4 , and LuVO 4 single crystals grown by the Czochralski (CZ) method with RF heating system are compared. All vanadate crystals show high transmittance (∼80%) in the 400-900 nm wavelength range. In both photo- and radio-luminescence spectra, intense peak around 400-500 nm, which was ascribed to the transition from triplet state of VO 4 3- , was clearly observed. The main decay time component was about 38 μs (YVO 4 ), 18 μs ((Lu 0.5 Y 0.5 )VO 4 ), and 17 μs (LuVO 4 ) under 340 nm excitation. The scintillation light yields of YVO 4 , (Lu 0.5 Y 0.5 )VO 4 , and LuVO 4 crystals (obtained from the 137 Cs excited pulse height spectra) were evaluated to be about 11,200, 10,700, and 10,300 ph/MeV, respectively.

  7. Comparative analysis of experimental methods for quantification of small amounts of oil in water

    DEFF Research Database (Denmark)

    Katika, Konstantina; Ahkami, Mehrdad; Fosbøl, Philip Loldrup

    2016-01-01

    ) and the quantification of oil is then difficult. In this study, we compare four approaches to determine the volume of the collected oil fraction in core flooding effluents. The four methods are: Image analysis, UV/visible spectroscopy, liquid scintillation counting, and low-field nuclear magnetic resonance (NMR...... comparison to a pre-made standard curve. Image analysis, UV/visible spectroscopy, and liquid scintillation counting quantify only the oil fraction by comparing with a pre-made standard curve. The image analysis technique is reliable when more than 0.1 ml oil is present, whereas liquid scintillation counting...... performs well when less than 0.6 ml oil is present. Both UV/visible spectroscopy and NMR spectrometry produced high accuracy results in the entire studied range (0.006-1.1 ml). In terms of laboratory time, the liquid scintillation counting is the fastest and least user dependent, whereas the NMR...

  8. Composition for use in scintillator systems

    International Nuclear Information System (INIS)

    Tarkkanen, V.

    1976-01-01

    A liquid scintillation counting composition of the type comprising an aromatic hydrocarbon solvent, an ethoxylated alkyl phenol surfactant, and a scintillation solute, containing a small amount of a substituted ethoxylated carboxylate acid and/or a tertiary amine salt or a quaternary ammonium salt of such acid is described. The free acid reduces chemiluminescence upon the addition of an alkaline sample to the composition, while the tertiary amine or quaternary ammonium salt enhances the water miscibility of the composition

  9. Recent Advances in Low-Level Scintillation Counting of Tritium; Progres recents dans le comptage a scintillations de faibles teneurs en tritium; Poslednie dostizheniya v oblasti stsintillyatsionnogo scheta tritiya nizkogo urovnya; Progresos recientes en el recuento por centelleo de bajas concentraciones de tritio

    Energy Technology Data Exchange (ETDEWEB)

    Kaufman, W J; Nir, A; Parks, G; Hours, R M [University of California, Berkeley, CA (United States)

    1962-01-15

    Studies have been made of the liquid scintillation counting system with the objective of optimizing detection sensitivity as expressed by a function of sample volume, efficiency and background. The investigation included a review of scintillator composition. A dioxane-naphthalene-water system having a water content of 18.6% was selected as the most satisfactory composition. Further studies of counting cell geometry and scintillator volume have led to the use of a cylindrical container of 'Teflon' with high gain quartz face photomultipliers in direct contact with the solution. This system gave a tritium detection sensitivity corresponding to a concentration of 0.55 x 10{sup -12} c/ml at an efficiency of 6.9% and a background of 52 cpm. A water sample volume of 31.6 ml was used with total scintillator volume of 170 ml. An internal Co{sup 57} source was found to be a suitable monitor of tritium-counting efficiency in the range 2 to 7% with a standard deviation of 0.1%. It has the advantage over previous methods in that it provided a rapid efficiency determination without modification of the sample. Studies of background reduction were made to evaluate the contribution of luminous interaction and cosmic radiation. A plastic envelope anticoincidence shield was used in the study. Long term effects on stability of the system caused by sample deterioration and counting equipment drifts were evaluated. (author) [French] Les auteurs ont etudie un dispositif de comptage a scintillateur liquide, en vue de rendre optimum la sensibilite de la detection, definie en fonction du volume de l'echantillon, du rendement de comptage et du bruit de fond. Les recherches ont porte notamment sur la composition du scintillateur. On a choisi un melange dioxane-naphthalene-eau, dans lequel cette derniere entrait pour 18,6%, parce que sa composition s'est revelee la plus satisfaisante. D'autres etudes, qui portaient sur la geometrie de la cellule de comptage et le volume du scintillateur, ont

  10. Measurement of light emission in scintillation vials

    International Nuclear Information System (INIS)

    Duran Ramiro, M. Teresa; Garcia-Torano, Eduardo

    2005-01-01

    The efficiency and energy resolution of liquid scintillation counting (LSC) systems are strongly dependent on the optical characteristics of scintillators, vials, and reflectors. This article presents the results of measurements of the light-emission profile of scintillation vials. Two measurement techniques, autoradiographs and direct measurements with a photomultiplier tube, have been used to obtain light-emission distribution for standard vials of glass, etched glass and polyethylene. Results obtained with both techniques are in good agreement. For the first time, the effect of the meniscus in terms of light contribution has been numerically estimated. These results can help design LSC systems that are more efficient in terms of light collection

  11. Pharmacy refill adherence compared with CD4 count changes for monitoring HIV-infected adults on antiretroviral therapy.

    Directory of Open Access Journals (Sweden)

    Gregory P Bisson

    2008-05-01

    Full Text Available World Health Organization (WHO guidelines for monitoring HIV-infected individuals taking combination antiretroviral therapy (cART in resource-limited settings recommend using CD4(+ T cell (CD4 count changes to monitor treatment effectiveness. In practice, however, falling CD4 counts are a consequence, rather than a cause, of virologic failure. Adherence lapses precede virologic failure and, unlike CD4 counts, data on adherence are immediately available to all clinics dispensing cART. However, the accuracy of adherence assessments for predicting future or detecting current virologic failure has not been determined. The goal of this study therefore was to determine the accuracy of adherence assessments for predicting and detecting virologic failure and to compare the accuracy of adherence-based monitoring approaches with approaches monitoring CD4 count changes.We conducted an observational cohort study among 1,982 of 4,984 (40% HIV-infected adults initiating non-nucleoside reverse transcriptase inhibitor-based cART in the Aid for AIDS Disease Management Program, which serves nine countries in southern Africa. Pharmacy refill adherence was calculated as the number of months of cART claims submitted divided by the number of complete months between cART initiation and the last refill prior to the endpoint of interest, expressed as a percentage. The main outcome measure was virologic failure defined as a viral load > 1,000 copies/ml (1 at an initial assessment either 6 or 12 mo after cART initiation and (2 after a previous undetectable (i.e., 0.5. In addition, adherence levels assessed 3 mo prior to viral load assessments were as accurate for virologic failure occurring approximately 3 mo later as were CD4 count changes calculated from cART initiation to the actual time of the viral load assessments, indicating the potential utility of adherence assessments for predicting future, rather than simply detecting current, virologic failure. Moreover

  12. Removal of impurities from environmental water samples for tritium measurement by means of liquid scintillation counter

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Noda, Mitsuyasu

    2000-01-01

    Tritium concentration in environmental water samples is usually measured by means of liquid scintillation counting. Before the counting distillation operation is necessarily required to remove impurities, which have possibility of bad influence on the measurement, from the samples. But the operation usually takes long time and it is also troublesome. If you could simplify the purification process, you would be much easily able to measure it. Then, we have studied the probability of replacement the process by filtration aiming to simplify the procedure. We prepared several environmental water samples and also several water samples added quenching materials. These samples were purified by means of the distillation and the filtration and the impurities in them were examined. The purified samples were mixed with scintillation cocktail and the tritium concentration was measured. We added small amount of tritium in the same samples and investigated their scintillation spectra and their ESCR values in order to compare the two purification methods. Two kinds of filters were used for the filtration: 0.45 μm and 0.1 μm pore sized membrane filters. The liquid scintillation counter was LB-3 produced by Aloka Co. and Ltd. The scintillation cocktail was Ultima Gold LLT made by Packard Instrument Co and Ltd. The vial was Polyvial 145 LSD made by Zinsser Analytic Co. and Ltd. As the result, there was no significant difference between the two purification methods then the filtration method is feasible instead of the distillation. (author)

  13. Nucleon fragmentation in pn and pp interactions compared with quark counting rules

    International Nuclear Information System (INIS)

    Bakken, V.; Breivik, F.O.; Jacobsen, T.

    New data on longitudinal invariant structure functions Edσ/dx for several low p(sub T) fragmentation processes in pn interactions at 19 GeV/c are presented, based on a bubble chamber study of pd collisions. The single particle processes n→π +- , p→π +- , n→p, n/p→rho 0 , p→p(sub inel) and p→Δ ++ (1232) as well as the di-pion processes n→π - π - , n→π + π + , n→π + π - and p→π - π - have been investigated. Previously published data on pp collisions at 19 GeV/c regarding p→π - , p→K 0 (sub s) and p→Λ have also been considered. The structure functions of these processes in the fragmentation region are adequately fitted by Edσ/dx proportional to (1-/x/)(sup n). Similar fits are made to published data on hadron-neutron interactions and ISR-data on pp→n+X. The values of n show no energy dependence. They are in qualitative agreement with the recently formulated quark counting rules, but some quantitative disagreements are observed. (Auth.)

  14. Comparing milk yield, chemical properties and somatic cell count from organic and conventional mountain farming systems

    Directory of Open Access Journals (Sweden)

    Marcello Bianchi

    2010-01-01

    Full Text Available A study was undertaken to investigate the effects of farming systems (organic vs. conventional, diet (hay/concentrate vs. pasture and their interaction on milk yield, gross composition and fatty acid (FA profile of dairy cows bred in mountainous areas. For this purpose four dairy farms (two organic and two conventional were chosen in the alpine territory of Aosta Valley (NW Italy; individual milk yield was recorded daily and bulk milk samples were collected monthly from February to September 2007 to cover dietary variations. Higher levels of milk production (P<0.05 and lower milk protein amounts (P<0.01 were observed in the organic farms with respect to the conventional ones, while no significant differences were noticed in milk fat and lactose contents and in somatic cell count. Concerning fatty acids, only small differences were detected between organic and conventional milk and such differences seemed to be related mainly to the stabled period. Diet affected almost all variables studied: pasture feeding provided a significant improvement in the fatty acid composition in both organic and conventional systems leading to lower hypercholesterolemic saturated fatty acids, higher mono- and polyunsaturated fatty acids and conjugated linoleic acid amounts (P<0.001.

  15. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1977-01-01

    A liquid scintillation solution is described which includes (1) a scintillation solvent (toluene and xylene), (2) a primary scintillation solute (PPO and Butyl PBD), (3) a secondary scintillation solute (POPOP and Dimethyl POPOP), (4) a plurality of substantially different surfactants and (5) a filter dissolving and/or transparentizing agent. 8 claims

  16. Scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Swank, R.K.; White, P.J.

    1978-01-01

    Scintillator structures are described in which the phosphor is embedded or suspended in an optically transparent matrix which is selected or adjusted to have an index of refraction which is approximately equal to that of the phosphor at the wavelength of the light emitted by the phosphor. The matrix may be glass, copoly 2-vinyl naphthalene/vinyl toluene or a liquid e.g. Br-naphthalene and optionally CH 3 I, the ratio of components being adjusted to give the desired refractive index. The polymer may be made in situ or a mixture of phosphor and polymer formed e.g. by freeze drying a solution and pulverizing, and then heating. Specified dyes may be used for converting the emitted light to other wavelengths. (author)

  17. Homicides by Police: Comparing Counts From the National Violent Death Reporting System, Vital Statistics, and Supplementary Homicide Reports.

    Science.gov (United States)

    Barber, Catherine; Azrael, Deborah; Cohen, Amy; Miller, Matthew; Thymes, Deonza; Wang, David Enze; Hemenway, David

    2016-05-01

    To evaluate the National Violent Death Reporting System (NVDRS) as a surveillance system for homicides by law enforcement officers. We assessed sensitivity and positive predictive value of the NVDRS "type of death" variable against our study count of homicides by police, which we derived from NVDRS coded and narrative data for states participating in NVDRS 2005 to 2012. We compared state counts of police homicides from NVDRS, Vital Statistics, and Federal Bureau of Investigation Supplementary Homicide Reports. We identified 1552 police homicides in the 16 states. Positive predictive value and sensitivity of the NVDRS "type of death" variable for police homicides were high (98% and 90%, respectively). Counts from Vital Statistics and Supplementary Homicide Reports were 58% and 48%, respectively, of our study total; gaps varied widely by state. The annual rate of police homicide (0.24/100,000) varied 5-fold by state and 8-fold by race/ethnicity. NVDRS provides more complete data on police homicides than do existing systems. Expanding NVDRS to all 50 states and making 2 improvements we identify will be an efficient way to provide the nation with more accurate, detailed data on homicides by law enforcement.

  18. Liquid emulsion scintillators which solidify for facile disposal

    International Nuclear Information System (INIS)

    O'Brien, R.E.; Krieger, J.K.

    1981-01-01

    A liquid organic scintillation cocktail is described which counts solutions of radiolabelled compounds containing up to ten % by volume of water with high efficiency and is readily polymerizable to a solid for easy disposal. The cocktail comprises a polymerizable organic solvent, a solubilizing agent, an intermediate solvent, and an organic scintillator. A method of disposing of liquid organic scintillation cocktail waste and a kit useful for practising the method are also described. (U.K.)

  19. Waveshifters and Scintillators for Ionizing Radiation Detection

    International Nuclear Information System (INIS)

    Baumgaugh, B.; Bishop, J.; Karmgard, D.; Marchant, J.; McKenna, M.; Ruchti, R.; Vigneault, M.; Hernandez, L.; Hurlbut, C.

    2007-01-01

    Scintillation and waveshifter materials have been developed for the detection of ionizing radiation in an STTR program between Ludlum Measurements, Inc. and the University of Notre Dame. Several new waveshifter materials have been developed which are comparable in efficiency and faster in fluorescence decay than the standard material Y11 (K27) used in particle physics for several decades. Additionally, new scintillation materials useful for fiber tracking have been developed which have been compared to 3HF. Lastly, work was done on developing liquid scintillators and paint-on scintillators and waveshifters for high radiation environments

  20. Timing performance of ZnO:Ga nanopowder composite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Turtos, Rosana M. [Universita degli Studi di Milano-Bicocca, Milano (Italy); Gundacker, Stefan; Lucchini, Marco T.; Lecoq, Paul; Auffray, Etiennette [CERN, Geneva (Switzerland); Prochazkova, Lenka; Cuba, Vaclav [Czech Technical University, Faculty of Nuclear Sciences and Physical Engineering, Prague (Czech Republic); Buresova, Hana [Nuvia a.s, Kralupy nad Vltavou (Czech Republic); Mrazek, Jan [Institute of Photonics and Electronics AS CR, Prague (Czech Republic); Nikl, Martin [Institute of Physics of the AS CR, Prague (Czech Republic)

    2016-11-15

    The implementation of nanocrystal-based composite scintillators as a new generation of ultrafast particle detectors is explored using ZnO:Ga nanopowder. Samples are characterized with a spectral-time resolved photon counting system and pulsed X-rays, followed by coincidence time resolution (CTR) measurements under 511 keV gamma excitation. Results are comparable to CTR values obtained using bulk inorganic scintillators. Bringing the ZnO:Ga nanocrystal's timing performance to radiation detectors could pave the research path towards sub-20 ps time resolution as shown in this contribution. However, an efficiency boost when placing nanopowders in a transparent host constitutes the main challenge in order to benefit from sub-nanosecond recombination times. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Scintillation counter, segmented shield

    International Nuclear Information System (INIS)

    Olson, R.E.; Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  2. Fabrication and a Study on the Tapered Scintillator Radiation Sensors

    International Nuclear Information System (INIS)

    Kim, Gye Hong

    2003-02-01

    Optical fibers have been investigated for their uses as sensor materials in various nuclear applications. Comprehensive overviews of their potential usages in nuclear environments can be found in the literatures. Optical fibers with doped scintillating elements in the core have drawn special interests as nuclear radiation detectors. The two important functions of a scintillating optical fiber, as a radiation detector, are scintillator (light emitter) and light transmitter. When radiation interacts with the core material, scintillation occurs and resultant lights are transmitted through the fiber to an opto-electronic device such as a photomultiplier tube. Optical fiber sensors have several advantages as compared to other sensors of conventional material. Since they do not require electric power in the sensor part, they are less susceptible to trouble in harsh environments such as underground or underwater. At relatively low cost a multi-point distributed radiation monitoring system could be made using the fiber sensors. Furthermore, unlike the conventional scintillating counters they are not influenced by any magnetic field surrounding them. This study has been conducted to investigate the feasibility of using scintillating optical fibers for the detection of gamma rays emitted by 137 Cs. Several types of gamma-ray sensors have been constructed by packing different numbers of fibers into aluminum tubes, and tested to detect the 137 Cs gamma ray. During the study it has been found that a tapered fibers might be more efficient to collect the lights produced inside the sensor and transfer them into the transmitting fiber. In order to investigate the effectiveness of the tapered fiber, tapered plastic scintillators, composed of polystyrene with minute amount of dPOPOP and PPO or bPBD, have been fabricated and tested for the detection of gamma rays from 1.0, 1.5, 3.0 and 5.0 μCi 137 Cs sources. The pulse height spectra and the relationship between the radioactivity and

  3. Determination of 90Sr in radioactive liquid waste-a comparative study using 'SrCO3 precipitation, extraction chromatography and Cerenkov radiation counting' techniques

    International Nuclear Information System (INIS)

    Mani, A.G.S.; Renganathan, K.; Rao, S.V.S.; Sinha, P.K.

    2007-01-01

    In the wastes generated at nuclear power plants, 90 Sr and 90 Y are responsible for approximately 7% and 38% of the total fission product activity after 1 year and 10 years respectively. Monitoring of the liquid waste produced in nuclear facilities for 90 Sr before and after releasing to the aquatic environment is essential, as it can cause a long term biological hazard due to its chemical similarity with Ca, high fission yield (5.9%) and long radioactive and biological half lives of 28 and 49.3 years respectively. As conventional carbonate precipitation method for 90 Sr- 90 Y estimation is laborious and time consuming, the other methods like extraction chromatography technique using strontium selective crown ether and Cerenkov radiation counting by liquid scintillation analyser (LSA) were also investigated. This paper describe procedures involved in the estimation of strontium in low-level radioactive liquid effluent by using above methods and deals with the comparison of results. Cerenkov radiation counting by LSA has an edge over the other methods in the determination of 90 Sr as it is a simple and rapid technique. Experiences gained in the estimation of 90 Sr in low-level radioactive liquid effluent using Cerenkov radiation counting technique is discussed in detail in this paper. (author)

  4. Some history of liquid scintillator development at Los Alamos

    International Nuclear Information System (INIS)

    Ott, D.G.

    1979-01-01

    The early developments in liquid scintillation counting made at Los Alamos Scientific Laboratory are reviewed. Most of the work was under the direction of F.N. Hayes and included counter development and applications as well as synthesis and chemistry of liquid scintillators

  5. Photon statistics in scintillation crystals

    Science.gov (United States)

    Bora, Vaibhav Joga Singh

    Scintillation based gamma-ray detectors are widely used in medical imaging, high-energy physics, astronomy and national security. Scintillation gamma-ray detectors are eld-tested, relatively inexpensive, and have good detection eciency. Semi-conductor detectors are gaining popularity because of their superior capability to resolve gamma-ray energies. However, they are relatively hard to manufacture and therefore, at this time, not available in as large formats and much more expensive than scintillation gamma-ray detectors. Scintillation gamma-ray detectors consist of: a scintillator, a material that emits optical (scintillation) photons when it interacts with ionization radiation, and an optical detector that detects the emitted scintillation photons and converts them into an electrical signal. Compared to semiconductor gamma-ray detectors, scintillation gamma-ray detectors have relatively poor capability to resolve gamma-ray energies. This is in large part attributed to the "statistical limit" on the number of scintillation photons. The origin of this statistical limit is the assumption that scintillation photons are either Poisson distributed or super-Poisson distributed. This statistical limit is often dened by the Fano factor. The Fano factor of an integer-valued random process is dened as the ratio of its variance to its mean. Therefore, a Poisson process has a Fano factor of one. The classical theory of light limits the Fano factor of the number of photons to a value greater than or equal to one (Poisson case). However, the quantum theory of light allows for Fano factors to be less than one. We used two methods to look at the correlations between two detectors looking at same scintillation pulse to estimate the Fano factor of the scintillation photons. The relationship between the Fano factor and the correlation between the integral of the two signals detected was analytically derived, and the Fano factor was estimated using the measurements for SrI2:Eu, YAP

  6. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  7. Uncovering the method of production and detection of synthetic acetic acid adulteration in vinegar by tandem use of {sup 1}4C liquid scintillation counting and {sup 1}3C/{sup 1}2C ratio mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wechner, Stefan; Voropaev, Andrey; Eichinger, Lorenz [HYDROISOTOP GmbHk Scweitenkirchen, Germany (Germany); Santos, Flora L; Castaneda, Soledad; Racho, Michael; Pabroa, Preciosa Corazon; Morco, Ryan; Sucgang, Raymond J [Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines)

    2010-07-01

    compared against a standard CO{sub 2} gas (standardized against the International Pee Dee Belemnite Standard). Delta values of acetic acid obtained from C4 plants including sugar cane, and pineapple were between (-12.2) to (-15.9) per mil respectively. The vinegar obtained from mango, a C3 plant, gave (-20.1) per mil. The acetic acid produced from sugar cane using an acetator presented a fractionation (-10.2 per mil.) which allows for it to be differentiated from cane vinegar produced via the conventional fermentation production, not using an acetator. Possible synthetic/petroleum derived vinegars exhibit delta values beyond (-30) per mil. Five out of seven of the commercial vinegar brands were suspected to be made of synthetic acetic acid. Isotope ratio mass spectrometry and liquid scintillation counting are promising tools for revealing the botanical origin and method of production, and detection of synthetic acid adulteration in vinegar samples. (author)

  8. Multi element high resolution scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.

    1980-01-01

    A gamma camera scintillator structure, suitable for detecting high energy gamma photons which, in a single scintillator camera, would require a comparatively thick scintillator crystal, so resulting in unacceptable dispersion of light photons, comprises a collimator array of a high Z material with elongated, parallel wall channels with the scintillator material being disposed in one end of the channels so as to form an integrated collimator/scintillator structure. The collimator channel walls are preferably coated with light reflective material and further light reflective surfaces being translucent to gamma photons, may be provided in each channel. The scintillators may be single crystals or preferably comprise a phosphor dispersed in a thermosetting translucent matrix as disclosed in GB2012800A. The light detectors of the assembled camera may be photomultiplier tubes charge coupled devices or charge injection devices. (author)

  9. Monte Carlo simulations and measurements for efficiency determination of lead shielded plastic scintillator detectors

    Science.gov (United States)

    Yasin, Zafar; Negoita, Florin; Tabbassum, Sana; Borcea, Ruxandra; Kisyov, Stanimir

    2017-12-01

    The plastic scintillators are used in different areas of science and technology. One of the use of these scintillator detectors is as beam loss monitors (BLM) for new generation of high intensity heavy ion in superconducting linear accelerators. Operated in pulse counting mode with rather high thresholds and shielded by few centimeters of lead in order to cope with radiofrequency noise and X-ray background emitted by accelerator cavities, they preserve high efficiency for high energy gamma ray and neutrons produced in the nuclear reactions of lost beam particles with accelerator components. Efficiency calculation and calibration of detectors is very important before their practical usage. In the present work, the efficiency of plastic scintillator detectors is simulated using FLUKA for different gamma and neutron sources like, 60Co, 137Cs and 238Pu-Be. The sources are placed at different positions around the detector. Calculated values are compared with the measured values and a reasonable agreement is observed.

  10. Discrimination methods between neutron and gamma rays for boron loaded plastic scintillators

    CERN Document Server

    Normand, S; Haan, S; Louvel, M

    2002-01-01

    Boron loaded plastic scintillators exhibit interesting properties for neutron detection in nuclear waste management and especially in investigating the amount of fissile materials when enclosed in waste containers. Combining a high thermal neutron efficiency and a low mean neutron lifetime, they are suitable in neutron multiplicity counting. However, due to their high sensitivity to gamma rays, pulse shape discrimination methods need to be developed in order to optimize the passive neutron assay measurement. From the knowledge of their physical properties, it is possible to separate the three kinds of particles that have interacted in the boron loaded plastic scintillator (gamma, fast neutron and thermal neutron). For this purpose, we have developed and compared the two well known discrimination methods (zero crossing and charge comparison) applied for the first time to boron loaded plastic scintillator. The setup for the zero crossing discrimination method and the charge comparison methods is thoroughly expl...

  11. A comparative study on the blood and milk cell counts of healthy, subclinical and clinical mastitis Karan Fries cows

    Directory of Open Access Journals (Sweden)

    Mohanned Alhussien

    2015-05-01

    Full Text Available Aim: The present study was aimed to study the use of cell counts as an early indicator of mammary health. Materials and Methods: Milk and blood cell counts were estimated from 8 healthy, 8 subclinical (SCM, and 8 clinically mastitis (CM groups of Karan Fries (KF cows. Results: Total leucocyte counts and neutrophil percent in blood and milk somatic cells and milk neutrophil percent of healthy cows increased significantly (p<0.05 in SCM cows and CM cows. Viability of blood and milk neutrophils was more in healthy cows, but decreased significantly (p<0.05 in SCM and CM cows. Significant (p<0.05 decrease were also observed in both the blood and milk lymphocytes and monocytes of SCM and CM cows. Phagocytic activity (PA of blood neutrophils also decreased significantly (p<0.05 in SCM cows. There was no difference between the PA of SCM and CM cows. Milk neutrophil percent was more in the SCM and clinically infected milk than in the blood of these cows. About 96-97% of the neutrophils had segmented nucleus in both healthy and subclinical milk, whereas, 2-3% were having band shaped or immature nuclei. There was a significant decrease in the segmented neutrophils, whereas, band neutrophils increase significantly to about 5% in the infected milk of mastitic cows. Viability of the milk neutrophils decreased more in case of subclinical and clinical milk as compared to that of blood. PA was found to be highest in the milk of healthy group of cows, but decreased significantly (p<0.05 in subclinically infected cows. However, there was no difference between the PA of milk neutrophils of SCM and CM cows. PA of milk was also found to be significantly lower in the milk of healthy cows when compared to that of blood neutrophils. Conclusion: This study indicated that percent neutrophils and their type in conjunction with milk somatic cell counts can be used as a more reliable indicator of mammary health in cows.

  12. Comparing and counting logs in direct and effective methods of QCD resummation

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Leandro G. [Laboratoire de Physique Théorique, Université Paris-Sud 11 and CNRS,91405 Orsay Cedex (France); Institut de Biologie de l’École Normale Supérieure (IBENS),Inserm 1024-CNRS 8197, 46 rue d’Ulm, 75005 Paris (France); Ellis, Stephen D. [Department of Physics, University of Washington,Seattle, WA 98195 (United States); Lee, Christopher [Theoretical Division, MS B283, Los Alamos National Laboratory,Los Alamos, NM 87544 (United States); Sterman, George [C.N. Yang Institute for Theoretical Physics, Stony Brook University,Stony Brook, NY 11794 (United States); Sung, Ilmo [Department of Applied Physics, New York University,Brooklyn, NY 11201 (United States); Queens College, City University of New York,Flushing, NY 11367 (United States); Walsh, Jonathan R. [Lawrence Berkeley National Laboratory, University of California,Berkeley, CA 94720 (United States); Berkeley Center for Theoretical Physics, University of California,Berkeley, CA 94720 (United States)

    2014-04-29

    We compare methods to resum logarithms in event shape distributions as they have been used in perturbative QCD directly and in effective field theory. We demonstrate that they are equivalent. In showing this equivalence, we are able to put standard soft-collinear effective theory (SCET) formulae for cross sections in momentum space into a novel form more directly comparable with standard QCD formulae, and endow the QCD formulae with dependence on separated hard, jet, and soft scales, providing potential ways to improve estimates of theoretical uncertainty. We show how to compute cross sections in momentum space to keep them as accurate as the corresponding expressions in Laplace space. In particular, we point out that that care is required in truncating differential distributions at N{sup k}LL accuracy to ensure they match the accuracy of the corresponding cumulant or Laplace transform. We explain how to avoid such mismatches at N{sup k}LL accuracy, and observe why they can also be avoided by working to N{sup k}LL{sup ′} accuracy.

  13. Buried plastic scintillator muon telescope (BATATA)

    International Nuclear Information System (INIS)

    Alfaro, R.; De Donato, C.; D'Olivo, J.C.; Guzman, A.; Medina-Tanco, G.; Moreno Barbosa, E.; Paic, G.; Patino Salazar, E.; Salazar Ibarguen, H.; Sanchez, F.A.; Supanitsky, A.D.; Valdes-Galicia, J.F.; Vargas Trevino, A.D.; Vergara Limon, S.; Villasenor, L.M.

    2010-01-01

    Muon telescopes have multiple applications in the area of cosmic ray research. We are currently building such a detector with the objective of comparing the ground penetration of muon vs. electron-gamma signals originated in cosmic ray showers. The detector is composed by a set of three parallel dual-layer scintillator planes, buried at fixed depths ranging from 120 to 600g/cm 2 . Each layer is 4m 2 and is composed by 49 rectangular strips of 4cmx2m, oriented at a 90 0 angle with respect to its companion layer, which gives an xy-coincidence pixel of 4x4cm 2 . The scintillators are MINOS extruded polystyrene strips, with an embedded Bicron BC92 wavelength shifting (WLS) fibers, of 1.5 mm in diameter. Light is collected by Hamamatsu H7546B multi-anode PMTs of 64 pixels. The front-end (FE) electronics works in counting mode and signals are transmitted to the surface DAQ stage using low-voltage differential signaling (LVDS). Any strip signal above threshold opens a GPS-tagged 2μs data collection window. Data, including signal and background, are acquired by a system of FPGA (Spartan 2E) boards and a single-board computer (TS7800).

  14. Buried plastic scintillator muon telescope (BATATA)

    Energy Technology Data Exchange (ETDEWEB)

    Alfaro, R. [Inst. de Fisica, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); De Donato, C.; D' Olivo, J.C.; Guzman, A.; Medina-Tanco, G. [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Moreno Barbosa, E. [Fac. de Ciencias Fisico Matematicas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Paic, G.; Patino Salazar, E. [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Salazar Ibarguen, H. [Fac. de Ciencias Fisico Matematicas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Sanchez, F.A., E-mail: federico.sanchez@nucleares.unam.m [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Supanitsky, A.D. [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Valdes-Galicia, J.F. [Inst. de Geofisica, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Vargas Trevino, A.D.; Vergara Limon, S. [Fac. de Ciencias de la Electronica, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Villasenor, L.M. [Inst. de Fisica y Matematicas, Universidad Michoacana de San Nicolas Hidalgo Morelia (Mexico); Observatorio Pierre Auger, Av. San Martin Norte 304 (5613) Malarguee, Prov. Mendoza (Argentina)

    2010-05-21

    Muon telescopes have multiple applications in the area of cosmic ray research. We are currently building such a detector with the objective of comparing the ground penetration of muon vs. electron-gamma signals originated in cosmic ray showers. The detector is composed by a set of three parallel dual-layer scintillator planes, buried at fixed depths ranging from 120 to 600g/cm{sup 2}. Each layer is 4m{sup 2} and is composed by 49 rectangular strips of 4cmx2m, oriented at a 90{sup 0} angle with respect to its companion layer, which gives an xy-coincidence pixel of 4x4cm{sup 2}. The scintillators are MINOS extruded polystyrene strips, with an embedded Bicron BC92 wavelength shifting (WLS) fibers, of 1.5 mm in diameter. Light is collected by Hamamatsu H7546B multi-anode PMTs of 64 pixels. The front-end (FE) electronics works in counting mode and signals are transmitted to the surface DAQ stage using low-voltage differential signaling (LVDS). Any strip signal above threshold opens a GPS-tagged 2{mu}s data collection window. Data, including signal and background, are acquired by a system of FPGA (Spartan 2E) boards and a single-board computer (TS7800).

  15. Determination of {sup 90}Sr, {sup 63}Ni and {sup 55}Fe activities by liquid scintillation counting in the environmental samples close to French nuclear power plants located on Loire and Garonne rivers

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, G.; Mokili, M.B.; Le Roy, C.; Deniau, I. [SUBATECH, IN2P3 (France); Gontier, G.; Boyer, C. [EDF-DPI-DIN-CIDEN (France); Hemidy, P.Y. [EDF-DPN-UNIE-GPRE-IEV (France); Chardon, P. [CNRS/IN2P3 (France)

    2014-07-01

    The protection of the aquatic and terrestrial environment from a wide range of radioactive contaminants released by nuclear industry requires continuous monitoring of radionuclides released into the environment. Specific measurement methods depending of the radionuclide are used to determinate this contribution. A lot of radionuclide can easily be measured at low level by gamma spectrometry, like {sup 137}Cs, {sup 60}Co..., but others like {sup 90}Sr, {sup 63}Ni or {sup 55}Fe require prior specific radiochemical separations. Activity of {sup 90}Sr values in environmental samples are available but only few measurements of {sup 63}Ni and {sup 55}Fe activities have been carried out in samples collected in the environment close to French nuclear power plants located on the Loire and Garonne rivers despite they represent 12% to 24% for {sup 63}Ni activity and <1% for {sup 55}Fe + other minor radionuclides of total activity of their liquid effluent discharges. {sup 90}Sr is not rejected by the liquid effluent discharges of Nuclear Power Plants and can be found in the environmental samples because of thermonuclear test and subsequently after the Chernobyl nuclear power plant accident. Considering the French Nuclear Power Plant located on Loire and Garonne rivers, the determination of {sup 90}Sr, {sup 63}Ni and {sup 55}Fe levels in the environmental samples around French nuclear power plants is carried out to detect the traces of these radionuclides originating from nuclear technology activities. The environment around five French nuclear Power Plants was investigated for 4 years between 2009 and 2014. The radionuclide activities determined by liquid scintillation counting after chemical steps were performed on a large set of various matrix samples likely to be encountered in environmental monitoring as soils, sediments, terrestrial and aquatic bio-indicators. It was found that the mean activity concentration of the most frequently detected was for the radionuclide {sup 90

  16. High efficiency scintillation detectors

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1976-01-01

    A scintillation counter consisting of a scintillation detector, usually a crystal scintillator optically coupled to a photomultiplier tube which converts photons to electrical pulses is described. The photomultiplier pulses are measured to provide information on impinging radiation. In inorganic crystal scintillation detectors to achieve maximum density, optical transparency and uniform activation, it has been necessary heretofore to prepare the scintillator as a single crystal. Crystal pieces fail to give a single composite response. Means are provided herein for obtaining such a response with crystal pieces, such means comprising the combination of crystal pieces and liquid or solid organic scintillator matrices having a cyclic molecular structure favorable to fluorescence. 8 claims, 6 drawing figures

  17. Liquid scintillation systems and apparatus for measuring high-energy radiation emitted by samples in standard laboratory test tubes

    International Nuclear Information System (INIS)

    Benvenutti, R.A.

    1976-01-01

    Liquid scintillation detection system employs improved sample holders in which the cap of a glass vial is provided with a well for receiving a standard laboratory test tube containing a radioactive sample. The well is immersed in a liquid scintillator in the vial, the scintillator containing lead acetate solution to enhance its efficiency. A commercially available beta-counting liquid scintillation apparatus is modified to provide gamma-counting with the improved sample holders

  18. A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors

    International Nuclear Information System (INIS)

    Acciavatti, Raymond J.; Maidment, Andrew D. A.

    2010-01-01

    is a binary function given as zero or unity everywhere. In analyzing the model detector with Gaussian blurring, the difference in NPS and DQE between the two detector types is found to increase with the blurring of the x-ray converter. Ultimately, the expression for the additive white noise of the photon counter is compared against the expression for electronic noise and secondary quantum noise in an energy integrator. Thus, a method is provided to determine the average secondary quanta that the energy integrator must produce for each x ray to have superior DQE to a photon counter with the same PSF. Conclusions: This article develops analytical models of OTF, NPS, and DQE for energy integrating and photon counting digital x-ray detectors. While many subtleties of real imaging systems have not been modeled, this work is illustrative in demonstrating an additive source of white noise in photon counting detectors which has not yet been described in the literature. One benefit of this analysis is a framework for determining the average secondary quanta that an energy integrating detector must produce for each x ray to have superior DQE to competing photon counting technology.

  19. Comparing sensitivity and count rate performance of small-bore DOI-PET scanners by computer simulation

    International Nuclear Information System (INIS)

    Kobayashi, Tetsuya; Takahashi, Hisashi; Yamaya, Taiga; Murayama, Hideo; Kitamura, Keishi; Hasegawa, Tomoyuki; Suga, Mikio

    2006-01-01

    In the development of a dedicated small-bore DOI-PET scanner for small animals (jPET-RD), we performed Monte Carlo simulations using the GATE based on Geant4 and investigated the influence of the proximity of the detectors to the target object on the sensitivity and count rate performance. The jPET-RD is based on a large-size depth-of-interaction (DOI) block detector that consists of a 4-layered array of 32 x 32 LSO crystals (1.4 mm x 1.4 mm x 4.5 mm) and a 256-ch flat panel position-sensitive photomultiplier tube. In this work, three detector geometries were simulated: two rings of six detector blocks arranged in a hexagonal pattern (FOV 85 mm in diameter) and four detector blocks arranged in a tetragonal pattern (FOV 49 mm in diameter) and in an overlapped tetragonal pattern (FOV 38 mm in diameter). The simulation results showed that the smaller bore geometry can provide higher sensitivity because of its larger solid angle. Although it clearly affected the noise equivalent count rate (NECR) due to its high dead-time, parallel readout with appropriate anode segmentation improved the NECR at 20 MBq by a factor of 1.1 to 1.4 compared with the case of 256-ch anodes read out by one front-end circuit. (author)

  20. Method for determining efficiency in a liquid scintillation system

    International Nuclear Information System (INIS)

    Laney, B.H.

    1975-01-01

    This invention relates to a method of counting radioactive events in a liquid scintillation radiation detecting and counting apparatus by utilizing pulses generated by a photomultiplying means resulting from scintillations caused by radioactive events. A counting efficiency value is assigned to each pulse generated in the photomultiplying means according to the height of the pulse. The numerical inverse of each assigned counting efficiency value is determined and each numerical inverse is recorded as an actual number of radioactive events with each having a pulse height identical to that of the corresponding pulse generated in the photomultiplying means. (Patent Office Record)

  1. Radioactive flow detectors: liquid or solid scintillators

    International Nuclear Information System (INIS)

    Reich, A.R.

    1983-01-01

    During the past five years, two schools of thought have emerged producing two different types of radio-HPLC detectors. Based on the naphthalene-in-the-vial principle, manufacturers have developed heterogeneous scintillation detectors. In these detectors the anthracene or naphthalene crystals are replaced by other scintillators. In order to avoid dead space and turbulence, a narrow diameter tube is used, either straight, or more popularly formed into a coil or a 'U' as the cell. To optimize light transmission to the photomultiplier tubes, mirrors are used. Due to limiting factors in this technique the counting efficiency for tritium is below the 10 percent level. The other school of radio-HPLC detectors based their design on classical liquid scintillation counting technology. In a homogeneous detector, the effluent from the HPLC system is mixed with a suitable liquid scintillator before entering the counting cell. The cell design is typically a flat glass or Teflon coil tightly sandwiched between two photomultiplier tubes, making good optical contact without the use of mirrors. Depending on the chromatographic effluent, 3 H efficiencies between 25 to 50 percent, and 14 C counting efficiencies up to 85 percent can be achieved

  2. Scintillators for positron emission tomography

    International Nuclear Information System (INIS)

    Moses, W.W.; Derenzo, S.E.

    1995-09-01

    Like most applications that utilize scintillators for gamma detection, Positron Emission Tomography (PET) desires materials with high light output, short decay time, and excellent stopping power that are also inexpensive, mechanically rugged, and chemically inert. Realizing that this ''ultimate'' scintillator may not exist, this paper evaluates the relative importance of these qualities and describes their impact on the imaging performance of PET. The most important PET scintillator quality is the ability to absorb 511 keV photons in a small volume, which affects the spatial resolution of the camera. The dominant factor is a short attenuation length (≤ 1.5 cm is required), although a high photoelectric fraction is also important (> 30% is desired). The next most important quality is a short decay time, which affects both the dead time and the coincidence timing resolution. Detection rates for single 511 keV photons can be extremely high, so decay times ≤ 500 ns are essential to avoid dead time losses. In addition, positron annihilations are identified by time coincidence so ≤5 ns fwhm coincidence pair timing resolution is required to identify events with narrow coincidence windows, reducing contamination due to accidental coincidences. Current trends in PET cameras are toward septaless, ''fully-3D'' cameras, which have significantly higher count rates than conventional 2-D cameras and so place higher demands on scintillator decay time. Light output affects energy resolution, and thus the ability of the camera to identify and reject events where the initial 511 keV photon has undergone Compton scatter in the patient. The scatter to true event fraction is much higher in fully-3D cameras than in 2-D cameras, so future PET cameras would benefit from scintillators with a 511 keV energy resolution < 10--12% fwhm

  3. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The invention deals with a liquid scintillation solution which contains 1) a scintillation solvent (toluol), 2) a primary scintillation solute (PPO), 3) a secondary scintillation solute (dimethyl POPOP), 4) several surfactants (iso-octyl-phenol polyethoxy-ethanol and sodium di-hexyl sulfosuccinate) essentially different from one another and 5) a filter resolution and/or transparent-making agent (cyclic ether, especially tetrahydrofuran). (HP) [de

  4. Scintillator manufacture at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Mellott, K.; Bross, A.; Pla-Dalmau, A.

    1998-08-01

    A decade of research into plastic scintillation materials at Fermilab is reviewed. Early work with plastic optical fiber fabrication is revisited and recent experiments with large-scale commercial methods for production of bulk scintillator are discussed. Costs for various forms of scintillator are examined and new development goals including cost reduction methods and quality improvement techniques are suggested.

  5. WORKSHOP: Scintillating fibre detectors

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Scintillating fibre detector development and technology for the proposed US Superconducting Supercollider, SSC, was the subject of a recent workshop at Fermilab, with participation from the high energy physics community and from industry. Sessions covered the current status of fibre technology and fibre detectors, new detector applications, fluorescent materials and scintillation compositions, radiation damage effects, amplification and imaging structures, and scintillation fibre fabrication techniques

  6. Liquid scintillation measurement. I

    International Nuclear Information System (INIS)

    Rexa, R.; Tykva, R.

    1983-01-01

    The individual components of scintillation solutions and their tasks are listed. Explained briefly is the scintillation process in a liquid scintillator. Factors are discussed which influence this process as are methods applied to supress their influence. They include: ionization quenching, quenching by dilution and concentration, chemical, colour, phase and photon quenching and single-photon events causing an undesirable backgorund. (M.D.)

  7. Comparative Evaluation of C-Reactive Protein and WBC Count in Fascial Space Infections of Odontogenic Origin.

    Science.gov (United States)

    Bagul, Ravikiran; Chandan, Sanjay; Sane, Vikrant Dilip; Patil, Sujay; Yadav, Dinesh

    2017-06-01

    To assess efficacy of C-reactive protein levels as monitoring tools for patients with fascial space infections of odontogenic origin. A randomized prospective study was conducted on 20 patients suffering from fascial space infection of odontogenic origin, in the department of Oral and Maxillofacial Surgery Bharati Vidyapeeth dental college and hospital, Pune, Patients between 18 and 60 years of age of both the sexes were selected. All patients were treated and observed by the same surgeon. Patient's venous blood sample was collected pre-operatively and on 2nd and 5th post-operative days for evaluation of WBC count and C-reactive protein (CRP). All patients were encouraged for strict follow-up protocol. Where the results of WBC count and CRP when compared it was seen that the mean values of WBC were normal in 15 cases and abnormal in 5 cases on day 0, day 2 and day 5; whereas the mean values of CRP were abnormal on day 0 and day 2 and were within normal limit on day 5 in all cases. The findings of this prospective analysis indicate that White blood cells and C-reactive protein are effective markers for determining severity of infection, efficacy of treatment regime for patients with fascial space infections of odontogenic origin. Thus the markers also help in making treatment of patients with fascial space infections of odontogenic origin more cost effective and they also help protecting patients from side effects of excess drugs usage. Thus we conclude that CRP should be incorporated as monitoring tools for managing patients with fascial space infections of odontogenic origin.

  8. Development of scintillation materials for PET scanners

    CERN Document Server

    Korzhik, Mikhail; Annenkov, Alexander N; Borissevitch, Andrei; Dossovitski, Alexei; Missevitch, Oleg; Lecoq, Paul

    2007-01-01

    The growing demand on PET methodology for a variety of applications ranging from clinical use to fundamental studies triggers research and development of PET scanners providing better spatial resolution and sensitivity. These efforts are primarily focused on the development of advanced PET detector solutions and on the developments of new scintillation materials as well. However Lu containing scintillation materials introduced in the last century such as LSO, LYSO, LuAP, LuYAP crystals still remain the best PET species in spite of the recent developments of bright, fast but relatively low density lanthanum bromide scintillators. At the same time Lu based materials have several drawbacks which are high temperature of crystallization and relatively high cost compared to alkali-halide scintillation materials. Here we describe recent results in the development of new scintillation materials for PET application.

  9. Clinical and Histologic Features Compared with AgNOR Count in Oral Leukoplakia, Erosive Lichen Planus, Oral Submucous Fibrosis and Oral Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Sarbjeet Singh

    2006-01-01

    The aim of the study was to correlate and compare AgNOR count in speckled leukoplakia, oral lichen planus, oral submucous fibrosis and in oral squamous cell carcinoma and to assess if AgNOR count could contribute to the pre-therapeutic assessment of the biologic aggressiveness of the disease and to detect malignant potential of premalignant lesion and conditions which could render us to assess the prognosis of the disease.

  10. Status of timing with plastic scintillation detectors

    International Nuclear Information System (INIS)

    Moszynski, M.; Bengtson, B.

    1979-01-01

    Timing properties of scintillators and photomultipliers as well as theoretical and experimental studies of time resolution of scintillation counters are reviewed. Predictions of the theory of the scintillation pulse generation processes are compared with the data on the light pulse shape from small samples, in which the light pulse shape depends only on the composition of the scintillator. For larger samples the influence of the light collection process and the self-absorption process on the light pulse shape are discussed. The data on rise times, fwhm's, decay times and light yield of several commercial scintillators used in timing are collected. The next part of the paper deals with the properties of photomultipliers. The sources of time uncertainties in photomultipliers as a spread of the initial velocity of photoelectrons, emission of photoelectrons under different angles and from different points at the photocathode, the time spread and the gain dispersion introduced by electron photomultiplier are reviewed. The experimental data on the time jitter, single electron response and photoelectron yield of some fast photomultipliers are collected. As the time resolution of the timing systems with scintillation counters depends also on time pick-off units, a short presentation of the timing methods is given. The discussion of timing theories is followed by a review of experimental studies of the time resolution of scintillation counters. The paper is ended by an analysis of prospects on further progress of the subnanosecond timing with scintillation counters. (Auth.)

  11. Comparative study using Monte Carlo methods of the radiation detection efficiency of LSO, LuAP, GSO and YAP scintillators for use in positron emission imaging (PET)

    International Nuclear Information System (INIS)

    Nikolopoulos, Dimitrios; Kandarakis, Ioannis; Tsantilas, Xenophon; Valais, Ioannis; Cavouras, Dionisios; Louizi, Anna

    2006-01-01

    The radiation detection efficiency of four scintillators employed, or designed to be employed, in positron emission imaging (PET) was evaluated as a function of the crystal thickness by applying Monte Carlo Methods. The scintillators studied were the LuSiO 5 (LSO), LuAlO 3 (LuAP), Gd 2 SiO 5 (GSO) and the YAlO 3 (YAP). Crystal thicknesses ranged from 0 to 50 mm. The study was performed via a previously generated photon transport Monte Carlo code. All photon track and energy histories were recorded and the energy transferred or absorbed in the scintillator medium was calculated together with the energy redistributed and retransported as secondary characteristic fluorescence radiation. Various parameters were calculated e.g. the fraction of the incident photon energy absorbed, transmitted or redistributed as fluorescence radiation, the scatter to primary ratio, the photon and energy distribution within each scintillator block etc. As being most significant, the fraction of the incident photon energy absorbed was found to increase with increasing crystal thickness tending to form a plateau above the 30 mm thickness. For LSO, LuAP, GSO and YAP scintillators, respectively, this fraction had the value of 44.8, 36.9 and 45.7% at the 10 mm thickness and 96.4, 93.2 and 96.9% at the 50 mm thickness. Within the plateau area approximately (57-59)% (59-63)% (52-63)% and (58-61)% of this fraction was due to scattered and reabsorbed radiation for the LSO, GSO, YAP and LuAP scintillators, respectively. In all cases, a negligible fraction (<0.1%) of the absorbed energy was found to escape the crystal as fluorescence radiation

  12. Pulse shape discrimination with scintillation detectors

    International Nuclear Information System (INIS)

    Winyard, R.A.

    A quantitative study of pulse shape discrimination with scintillation counters has been undertaken using a crossover timing technique. The scintillators investigated included experimental and commercial liquids and plastics in addition to inorganic phosphors. The versatility of the pulse shape discrimination system has been demonstrated by extending the measurements to investigate phoswiches and liquids loaded with radioactive materials and by its application to the suppression of unwanted backgrounds in delayed coincidence counting for the measurement of nuclear half-lives and isotope identification have been carried out. (author)

  13. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  14. Comparative study of large samples (2'' × 2'') plastic scintillators and EJ309 liquid with pulse shape discrimination (PSD) capabilities

    International Nuclear Information System (INIS)

    Iwanowska-Hanke, J; Moszynski, M; Swiderski, L; Sibczynski, P; Szczesniak, T; Krakowski, T; Schotanus, P

    2014-01-01

    In the paper we reported on the scintillation properties and pulse shape discrimination (PSD) performance of new plastic scintillators. The samples with dimension of 2 inches × 2 inches were tested: EJ299-34, EJ299-34G, EJ299-33 and EJ299-33G. They are the first commercially available plastics with neutron/gamma discrimination properties. The paper covers the measurements of emission spectra, photoelectron yield, analysis of the light pulse shapes originating from events related to gamma-rays and fast neutrons as well as neutron/gamma discrimination. The tested plastics are characterized by a photoelectron yield on a level of approximately 1600-2500 phe/MeV, depending on the sample. The highest value, measured for EJ299-34, is similar to the number of photoelectrons measured for EJ309 (2600 phe/MeV). The figure of merit (FOM) calculated for narrow energy cuts — indicating the PSD performance — showed that the PSD capabilities of the plastics are significantly lower than of EJ309. These scintillators are still under development in order to optimize the composition and manufacturing procedures. At this time the results obtained with the new plastics suggest their possible use as an alternative for liquid scintillators, especially if we consider their inflammability and non-toxicity

  15. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples; Desempeno de dos centelleadores liquidos y optimizacion de un contador Wallac 1411 en la cuantificacion de tritio en muestras acuosas

    Energy Technology Data Exchange (ETDEWEB)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  16. Liquid scintillator mixable with water

    International Nuclear Information System (INIS)

    Benson, R.H.

    1976-01-01

    A liquid scintillator mixable with water is described consisting of an aromatic solvent (xylene), a scintillation material and an ethoxylated alkyl phenol (as surface-active substance). So far such kinds of system have not given good measurements on counting samples with high water content. Due to the invention's composition one gets good results even with counting samples having a water content of over 30% if the alkyl substituent of the alkyl phenol contains 7, 10, 11, 13, 14, 15 or 16 C atoms and the ratio n/x of the number n of C atoms of the alkyl substituents to the average number x of the ethoxy groups of the ethoxylated alkyl phenols lie between 0.83 and 1.67. The following alkyl phenols are mentioned: heptyl phenol (n/x between 0.83 and 1.08), decyl phenol (n/x between 0.90 and 1.17), hendecyl phenol (n/x between 0.93 and 1.22), tridecyl phenol (n/x between 0.97 and 1.34), tetradecyl phenol (n/x between 1.08 and 1.55), pentadecyl phenol (n/x between 1.15 and 1.67), hexadecyl phenol (n/x between 1.33 and 1.51). (UWI) [de

  17. Scintillation 1024-channel hodoscope

    International Nuclear Information System (INIS)

    Kotov, I.V.; Krasnokutskij, R.N.; Kurbakov, V.I.; Shchukin, A.V.

    1993-01-01

    Flow diagram of voltage divider for photomultiplier used in scintillation multichannel hodoscope is described. The suggested diagram of the divider allows to optimize potential distribution at the innput chamber (photocathode - modulator - first dynode) and in the tail segment of the divider (the nineth dynode-anode). Adjustment of high voltage is conducted using multirotational potentiometer switched in series with the divider. Amplifier-limiter with 80 mkA threshold set at voltage comparator is placed at divide plate. Threshold of its sensitivity constitutes 80 mkA. Hodoscope supply system consists of supply sources of comparators (+-6V) four sources of auxiliary supply sources of the last dynodes of photomultipliers and high-voltage source. Current consumption constitutes 25 A by - 6V, 23 A by + 6 V for the whole hodoscope and up to 200 mA from high-voltage source for one plane. Additional charging sources have constant consumption equal to ∼ 20 mA

  18. Development of a reference liquid scintillation cocktail

    CSIR Research Space (South Africa)

    Van Wyn Gaardt, WM

    2006-02-01

    Full Text Available A reference system that would allow national laboratories to compare their activity measurements of non-gamma-emitting radionuclides at any time is currently being developed. The system requires a non-commercial reference-liquid scintillation...

  19. Scintillator materials

    International Nuclear Information System (INIS)

    1976-01-01

    The invention describes the chemical preparation of inorganic phosphors, i.e. cerium- and praseodymium pentaphosphate. The advantages, as compared to usual phosphors, are improved optical properties and a shorter duration (12 ns) of the afterglow. A discussion of various applications, e.g. in diode tubes, cathode ray tubes, gas discharge tubes, in electroluminescence, and in electron microscopes are given

  20. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM

    International Nuclear Information System (INIS)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-01-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. - Highlights: • First practical application of epitaxial garnet films demonstrated in SEM. • Improved image quality of SEM equipped with GAGG:Ce single crystalline thin film scintillator. • Scintillation properties of GAGG:Ce films compared with standard bulk crystal scintillators.

  1. Radioactivity measurements by liquid scintillation spectroscopy

    International Nuclear Information System (INIS)

    Cassette, Ph.

    2004-01-01

    The activity measurement techniques by liquid scintillation spectroscopy consist to mix the radioactive solution to measure with a scintillating liquid and to transform the ionizing radiations, resulting from decays, into light, detectable and quantifiable. The main advantages of these techniques are the easiness of preparation of the radioactive sources, the geometric efficiency of detection of 4π and the possibility of detection of low-level energy radiations. There are one of the only methods giving the possibility to measure the activity of pure β radionuclides; indeed, the nuclear disintegration is not accompanied of gamma radiations detectable by other techniques. There are one of the only methods too of measurement of radionuclides which disintegrate by electron capture and especially those leading to the emission of low-level energy ionizing radiations. Liquid scintillation spectroscopy can be used as an absolute method of activity measurement that is to say without the use of a calibration standard. The modern liquid scintillation counting devices can be very sensitive; the measurement of micro-activities being possible. Some of the applications of these activity measurement techniques are the carbon 14 dating and the geological tracing. Their main disadvantage is the global energetic yield which is low and variable in terms of the composition of the scintillation source necessitating to calculate the detection yield for each condition of measurement. (O.M.)

  2. Estimation of Fano factor in inorganic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Bora, Vaibhav, E-mail: bora.vaibhav@gmail.com [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Barrett, Harrison H., E-mail: barrett@radiology.arizona.edu [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Fastje, David, E-mail: dfastje@gmail.com [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Clarkson, Eric, E-mail: clarkson@radiology.arizona.edu [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Furenlid, Lars, E-mail: furen@radiology.arizona.edu [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Bousselham, Abdelkader, E-mail: abousselham@qf.org.qa [Qatar Foundation, QEERI, P.O. Box 5825, Doha (Qatar); Shah, Kanai S., E-mail: kanaishah@yahoo.com [Radiation Monitoring Devices, Inc., Watertown, MA 02472 (United States); Glodo, Jarek, E-mail: jglodo@rmdinc.com [Radiation Monitoring Devices, Inc., Watertown, MA 02472 (United States)

    2016-01-01

    The Fano factor of an integer-valued random variable is defined as the ratio of its variance to its mean. Correlation between the outputs of two photomultiplier tubes on opposite faces of a scintillation crystal was used to estimate the Fano factor of photoelectrons and scintillation photons. Correlations between the integrals of the detector outputs were used to estimate the photoelectron and photon Fano factor for YAP:Ce, SrI{sub 2}:Eu and CsI:Na scintillator crystals. At 662 keV, SrI{sub 2}:Eu was found to be sub-Poisson, while CsI:Na and YAP:Ce were found to be super-Poisson. An experiment setup inspired from the Hanbury Brown and Twiss experiment was used to measure the correlations as a function of time between the outputs of two photomultiplier tubes looking at the same scintillation event. A model of the scintillation and the detection processes was used to generate simulated detector outputs as a function of time for different values of Fano factor. The simulated outputs from the model for different Fano factors was compared to the experimentally measured detector outputs to estimate the Fano factor of the scintillation photons for YAP:Ce, LaBr{sub 3}:Ce scintillator crystals. At 662 keV, LaBr{sub 3}:Ce was found to be sub-Poisson, while YAP:Ce was found to be close to Poisson.

  3. Comparative evaluation of platelet count and antimicrobial efficacy of injectable platelet-rich fibrin with other platelet concentrates: An in vitro study

    Directory of Open Access Journals (Sweden)

    Prerna Ashok Karde

    2017-01-01

    Full Text Available Background: Platelet concentrates are used in various medical procedures to promote soft- and hard-tissue regeneration. In recent times, their antimicrobial efficacy is also explored. However, various platelet concentrates have evolved which differ in the centrifugation protocols. One such recently introduced platelet concentrate is injectable platelet-rich fibrin (i-PRF concentrate. Hence, the aim was to evaluate the antimicrobial property, and platelet count of i-PRF in comparison to other platelet concentrates, i.e., PRF, platelet-rich plasma (PRP, and control (whole blood. Materials and Methods: Blood samples were obtained from 10 chronic generalized marginal gingivitis patients. Platelet concentrates were prepared using standardized centrifugation protocol. Platelet count was evaluated by manual counting method using smear preparation of each sample. Subsequently, antimicrobial activity against oral bacteria was examined on blood agar using disc diffusion method to quantify the inhibitory effects. Results: Statistical significance was analyzed by one-way analysis of variance (ANOVA. P 0.05. i-PRF showed statistically significant difference (P < 0.001 in platelet count when compared to control. It was also significant when compared to PRP (P < 0.01, PRF (P < 0.001. Conclusion: i-PRF has maximum antimicrobial efficacy and higher platelet count in comparison to other platelet concentrates, thereby indicating to have a better regenerative potential then others.

  4. Development of water radiocontamination monitor using a plastic scintillator detector

    International Nuclear Information System (INIS)

    Mesquita, C.H. de; Madi Filho, T.; Hamada, M.M.

    1990-01-01

    An alpha, beta and gamma radiation water monitor was developed using a plastic scintillator detector with a sensitivity level of 15 bplastic scintillator detector with a sensitivity level of 15 Bq.L -1 and a counting efficiency of 25% for 131 I. It was proposed to be used in the radiation monitoring program of the research reactor swimming-pool of Sao Paulo. A simplified design and some properties of this monitor are presented. (author) [pt

  5. Comparative Investigation of Ce3+ Doped Scintillators in a Wide Range of Photon Energies Covering X-ray CT, Nuclear Medicine and Megavoltage Radiation Therapy Portal Imaging Applications

    Science.gov (United States)

    Valais, Ioannis G.; Michail, Christos M.; David, Stratos L.; Liaparinos, Panagiotis F.; Fountos, George P.; Paschalis, Theodoros V.; Kandarakis, Ioannis S.; Panayiotakis, George S.

    2010-02-01

    The aim of the present work is to study the performance of scintillators currently used in PET and animal PET systems, under conditions met in radiation therapy and PET/CT imaging. The results of this study will be useful in applications where both CT and PET photons as well as megavoltage cone beam CT (MV CBCT) photons could be detected using a common detector unit. To this aim crystal samples of GSO, LSO, LYSO, LuYAP and YAP scintillators, doped with cerium (Ce+3) were examined under a wide energy range of photon energies. Evaluation was performed by determining the absolute luminescence efficiency (emitted light flux over incident X-ray exposure) in the energy range employed in X-ray CT, in Nuclear Medicine (70 keV up to 662 keV) and in radiotherapy 6 MV (approx. 2.0 MeV mean energy)-18 MV (approx. 4.5 MeV mean energy). Measurements were performed using an experimental set-up based on a photomultiplier coupled to a light integration sphere. The emission spectrum under X-ray excitation was measured, using an optical grating monochromator, to determine the spectral compatibility to optical photon detectors incorporated in medical imaging systems. Maximum absolute luminescence efficiency values were observed at 70 keV for YAP:Ce and LuYAP:Ce and at 140 keV for LSO:Ce, LYSO:Ce and GSO:Ce. Highest absolute efficiency between the scintillators examined was observed for LSO:Ce, followed by LYSO:Ce. The detector optical gain (DOG) exhibited a significant variation with the increase of energy between 70 keV to 2.0 MeV. All scintillators exhibited low compatibility when combined with GaAsP (G5645) photodetector.

  6. Scintillator material. Szintillatormaterial

    Energy Technology Data Exchange (ETDEWEB)

    Siegmund, M; Bendig, J; Regenstein, W

    1987-11-25

    A scintillator material for detection and quantitative determination of ionizing radiation is discussed consisting of an acridone dissolved in a fluid or solid medium. Solvent mixtures with at least one protogenic component or polymers and copolymers are used. The scintillator material is distinguished by an excellent stability at high energy doses.

  7. Comparative seric TGF(β1, β2) levels and platelets count response in total body irradiated baboons

    International Nuclear Information System (INIS)

    Mestries, J.C.; Veyret, J.; Agay, D.; Van Uye, A.; Caterini, R.; Herodin, F.; Mathieu, J.; Chancerelle, Y.

    1994-01-01

    Total body irradiation associated or not with r-hIL-6 treatment a relation between TGF-β1 and TGF-β2 blood levels and platelets count. During radio-induced thrombocytopenia, by decreasing its ability to inhibit proliferation of stem cells and megakaryocytopoiesis, the TGF-β falling induced a favorable condition for hematopoietic recovery. (author)

  8. Neutron diffraction measurements at the INES diffractometer using a neutron radiative capture based counting technique

    Energy Technology Data Exchange (ETDEWEB)

    Festa, G. [Centro NAST, Universita degli Studi di Roma Tor Vergata, Roma (Italy); Pietropaolo, A., E-mail: antonino.pietropaolo@roma2.infn.it [Centro NAST, Universita degli Studi di Roma Tor Vergata, Roma (Italy); Grazzi, F.; Barzagli, E. [CNR-ISC Firenze (Italy); Scherillo, A. [CNR-ISC Firenze (Italy); ISIS facility Rutherford Appleton Laboratory (United Kingdom); Schooneveld, E.M. [ISIS facility Rutherford Appleton Laboratory (United Kingdom)

    2011-10-21

    The global shortage of {sup 3}He gas is an issue to be addressed in neutron detection. In the context of the research and development activity related to the replacement of {sup 3}He for neutron counting systems, neutron diffraction measurements performed on the INES beam line at the ISIS pulsed spallation neutron source are presented. For these measurements two different neutron counting devices have been used: a 20 bar pressure squashed {sup 3}He tube and a Yttrium-Aluminum-Perovskite scintillation detector. The scintillation detector was coupled to a cadmium sheet that registers the prompt radiative capture gamma rays generated by the (n,{gamma}) nuclear reactions occurring in cadmium. The assessment of the scintillator based counting system was done by performing a Rietveld refinement analysis on the diffraction pattern from an ancient Japanese blade and comparing the results with those obtained by a {sup 3}He tube placed at the same angular position. The results obtained demonstrate the considerable potential of the proposed counting approach based on the radiative capture gamma rays at spallation neutron sources.

  9. A comparative study on the mast cells count in oral squamous cell carcinoma and normal oral mucosa

    Directory of Open Access Journals (Sweden)

    Mahsa Dastpak

    2015-03-01

    Full Text Available Introduction: Oral squamous cell carcinoma (OSCC is one of the 10 most common malignant tumors and SCC accounts 94% of all oral malignancies. Mast cells are regarded as complex and multifunctional cells, playing a significant role in immunopathology . The aim of this study is to evaluate the number of mast cells in tissue sections of oral squamous cell carcinoma (OSCC in comparison with normal mucosa. Materials & Methods: Sixty paraffin-embedded specimens were obtained from the archives of the Department of Oral and Maxillofacial Pathology,dental school of Babol university of medical science (15 high grade,15 low grade and 30 Iritation Fibroma. Classification of OSCC cases was according to the BRODER`S malignancy grading system. Hematoxylin and Eosin-stained slides were re-evaluated before entering the samples in our study. Toluidine blue(1% staining was used to identify Mast cells in samples . We used SPSS software version 18 and one way ANOVA test for analyzing data. Results: The highest mast cell count was seen in normal tissue and it was higher in low grade OSCC in comparison with high grade, but the differences between groups weren’t statistically significant. The Mean count of mast cell between OSCC and normal oral mucosa was statistically significant different(p=0.019.We didn’t observe any statistically significant difference between Mast cell counts of control group and low grade OSCC . The same result was seen between high garde and low grade OSCC . The Mean mast cell count difference between male and female groups weren’t statistically significant. The Mean mast cell count difference between high grade OSCC and control group was significant (p<0.05. Conclusion: According to the results, the average amount of mast cells decreased in OSCC in comparison with normal oral mucosa . It does not seem that mast cells play an important role in tumor progression, although further study is needed. 

  10. Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy

    International Nuclear Information System (INIS)

    Scott Ingram, W.; Robertson, Daniel; Beddar, Sam

    2015-01-01

    Liquid scintillators are a promising detector for high-resolution three-dimensional proton therapy dosimetry. Because the scintillator comprises both the active volume of the detector and the phantom material, an ideal scintillator will exhibit water equivalence in its radiological properties. One of the most fundamental of these is the scintillator’s stopping power. The objective of this study was to compare calculations and measurements of scintillator-to-water stopping power ratios to evaluate the suitability of the liquid scintillators BC-531 and OptiPhase HiSafe 3 for proton dosimetry. We also measured the relative scintillation output of the two scintillators. Both calculations and measurements show that the linear stopping power of OptiPhase is significantly closer to water than that of BC-531. BC-531 has a somewhat higher scintillation output. OptiPhase can be mixed with water at high concentrations, which further improves its scintillator-to-water stopping power ratio. However, this causes the solution to become cloudy, which has a negative impact on the scintillation output and spatial resolution of the detector. OptiPhase is preferred over BC-531 for proton dosimetry because its density and scintillator-to-water stopping power ratio are more water equivalent

  11. A new technique for infrared scintillation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Chiossi, F., E-mail: federico.chiossi@studenti.unipd.it [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Brylew, K. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Borghesani, A.F. [CNISM Unit and Dip. di Fisica e Astronomia, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Braggio, C.; Carugno, G. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Drozdowski, W. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Guarise, M. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy)

    2017-05-21

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu{sub 0.75}Y{sub 0.25}){sub 3}Al{sub 5}O{sub 12} sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  12. A new technique for infrared scintillation measurements

    International Nuclear Information System (INIS)

    Chiossi, F.; Brylew, K.; Borghesani, A.F.; Braggio, C.; Carugno, G.; Drozdowski, W.; Guarise, M.

    2017-01-01

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu_0_._7_5Y_0_._2_5)_3Al_5O_1_2 sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  13. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  14. Operation of CdZnTe Semiconductor Detectors in Liquid Scintillator for the COBRA Experiment

    International Nuclear Information System (INIS)

    Oldorf, Christian

    2015-08-01

    COBRA, the Cadmium-Zinc-Telluride O-neutrino double-Beta Research Apparatus, is an experiment aiming for the measurement of the neutrinoless double beta decay with several isotopes, in particular 116 Cd, 106 Cd and 130 Te. A highly granular large scale experiment with about 400 kg of CdZnTe semiconductor detectors is currently under development. To provide evidence for the neutrinoless double beta decay of 116 Cd, a background rate in the order of 10 -3 counts/keV/kg/a is needed to achieve the required half-life sensitivity of at least 2 . 10 26 years. To reach this target, the detectors have to be operated in a highly pure environment, shielded from external radiation. Liquid scintillator is a promising candidate as a circum fluent replacement for the currently used lacquer. Next to the function as highly pure passivation material, liquid scintillator also acts as a neutron shield and active veto for external gammas. Within this thesis, the design, construction and assembly of a test set-up is described. The operation of four CdZnTe detectors after several years of storage in liquid scintillator is demonstrated. Next to extensive material compatibility tests prior to the assembly, the commissioning of the set-up and the characterization of the detectors are shown. Finally, results concerning the background reduction capability of liquid scintillator and the detection of cosmic muons are presented and compared to a Monte Carlo simulation.

  15. Evaluation of biodegradable and nonbiodegradable liquid scintillation cocktails used for tritium-in-water and urine analyses

    International Nuclear Information System (INIS)

    Haddock, J.A.

    1992-11-01

    The performance of a number of liquid scintillation cocktails was evaluated for quench resistance, sample capacity, cost, waste reduction and limit of detection. Directed towards the specific applications of counting tritium in water and urine samples, this study illustrated the potential of the newer, biodegradable cocktails, which mostly exhibited comparable or superior counting performance to the traditional cocktails. Reduced cocktail volumes and the use of mini vials is recommended for medium-load cocktails used for routine urine or water analyses, since a significant decrease in the volume of waste generated in Canadian nuclear facilities would result. (Author) (13 refs., 5 tabs., 44 figs.)

  16. Silicon photomultipliers for scintillating trackers

    Energy Technology Data Exchange (ETDEWEB)

    Rabaioli, S., E-mail: simone.rabaioli@gmail.com [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); Berra, A.; Bolognini, D. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Bonvicini, V. [INFN sezione di Trieste (Italy); Bosisio, L. [Universita degli Studi di Trieste and INFN sezione di Trieste (Italy); Ciano, S.; Iugovaz, D. [INFN sezione di Trieste (Italy); Lietti, D. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Penzo, A. [INFN sezione di Trieste (Italy); Prest, M. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Rashevskaya, I.; Reia, S. [INFN sezione di Trieste (Italy); Stoppani, L. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); Vallazza, E. [INFN sezione di Trieste (Italy)

    2012-12-11

    In recent years, silicon photomultipliers (SiPMs) have been proposed as a new kind of readout device for scintillating detectors in many experiments. A SiPM consists of a matrix of parallel-connected pixels, which are independent photon counters working in Geiger mode with very high gain ({approx}10{sup 6}). This contribution presents the use of an array of eight SiPMs (manufactured by FBK-irst) for the readout of a scintillating bar tracker (a small size prototype of the Electron Muon Ranger detector for the MICE experiment). The performances of the SiPMs in terms of signal to noise ratio, efficiency and time resolution will be compared to the ones of a multi-anode photomultiplier tube (MAPMT) connected to the same bars. Both the SiPMs and the MAPMT are interfaced to a VME system through a 64 channel MAROC ASIC.

  17. Silicon photomultipliers for scintillating trackers

    Science.gov (United States)

    Rabaioli, S.; Berra, A.; Bolognini, D.; Bonvicini, V.; Bosisio, L.; Ciano, S.; Iugovaz, D.; Lietti, D.; Penzo, A.; Prest, M.; Rashevskaya, I.; Reia, S.; Stoppani, L.; Vallazza, E.

    2012-12-01

    In recent years, silicon photomultipliers (SiPMs) have been proposed as a new kind of readout device for scintillating detectors in many experiments. A SiPM consists of a matrix of parallel-connected pixels, which are independent photon counters working in Geiger mode with very high gain (∼106). This contribution presents the use of an array of eight SiPMs (manufactured by FBK-irst) for the readout of a scintillating bar tracker (a small size prototype of the Electron Muon Ranger detector for the MICE experiment). The performances of the SiPMs in terms of signal to noise ratio, efficiency and time resolution will be compared to the ones of a multi-anode photomultiplier tube (MAPMT) connected to the same bars. Both the SiPMs and the MAPMT are interfaced to a VME system through a 64 channel MAROC ASIC.

  18. Scintillation counter: photomultiplier tube alignment

    International Nuclear Information System (INIS)

    Olson, R.E.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into the sample receiving zone. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (auth)

  19. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  20. Survey meter using novel inorganic scintillators

    International Nuclear Information System (INIS)

    Yoshikawa, Akira; Fukuda, Kentaro; Kawaguchi, Noriaki; Kamada, Kei; Fujimoto, Yutaka; Yokota, Yuui; Kurosawa, Shunsuke; Yanagida, Takayuki

    2012-01-01

    Single crystal scintillator materials are widely used for detection of high-energy photons and particles. There is continuous demand for new scintillator materials with higher performance because of increasing number of medical, industrial, security and other applications. This article presents the recent development of three novel inorganic scintillators; Pr-doped Lu 3 Al 5 O 12 (Pr:LuAG), Ce doped Gd 3 (Al, Ga) 5 O 12 (Ce:GAGG) and Ce or Eu-doped 6 LiCaAlF 6 (Ce:LiCAF, Eu:LiCAF). Pr:LuAG shows very interesting scintillation properties including very fast decay time, high light yield and excellent energy resolution. Taking the advantage of these properties, positron emission mammography (PEM) equipped with Pr:LuAG were developed. Ce:GAGG shows very high light yield, which is much higher than that of Ce:LYSO. Survey meter using Ce:GAGG is developed using this scintillator. Ce:LiCAF and Eu:LiCAF were developed for neutron detection. The advantage and disadvantage are discussed comparing with halide scintillators. Eu-doped LiCAF indicated five times higher light yield than that of existing Li-glass. It is expected to be used as the alternative of 3 He. (author)

  1. (Alpha-) quenching temperature dependence in liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Arnd; Lozza, Valentina; Krosigk, Belina von; Zuber, Kai [Institut fuer Kern- und Teilchenphysik, TU Dresden (Germany)

    2015-07-01

    Liquid scintillator (LS) is an effective and promising detector material, which is and will be used by many small and large scale experiments. In order to perform correct signal identification and background suppression, a very good knowledge of LS properties is crucial. One of those is the light yield from alpha particles in liquid scintillator. This light output strongly quenched, approx. 10 times compared to that of electrons, and has been precisely studied at room temperature for various LS. Big scintillator experiments, such as SNO+ and maybe future large scale detectors, will operate at different temperatures. While a strong temperature dependence is well known for solid state scintillators, due to the different scintillation process, a quenching temperature dependence in LS is usually assumed negligible. On the other hand, inconsistencies in between measurements are often explained by potential temperature effects. This study investigates LAB based liquid scintillator with an intrinsic, dissolved alpha emitter and its behaviour with temperature change. In a small, cooled and heated setup, a stabilized read-out with two PMTs is realised. First results are presented.

  2. A gamma-ray discriminating neutron scintillator

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.; Cole, M.C.

    1994-01-01

    A neutron scintillator has been developed at Pacific Northwest Laboratory which responds directly to as little as 10 mrem/hour dose equivalent rate fast neutron fields. The scintillator is composed of CaF 2 :Eu or of NaI grains within a silicone rubber or polystyrene matrix, respectively. Neutrons colliding with the plastic matrix provide knockon protons, which in turn deposit energy within the grains of phosphor to produce pulses of light. Neutron interactions are discriminated from gamma-ray events on the basis of pulse height. Unlike NE-213 liquid scintillators, this solid scintillator requires no pulseshape discrimination and therefore requires less hardware. Neutron events are anywhere from two to three times larger than the gamma-ray exposures are compared to 0.7 MeV gamma-ray exposures. The CaF 2 :Eu/silicone rubber scintillator is nearly optically transparent, and can be made into a very sizable detector (4 cm x 1.5 cm) without degrading pulse height. This CaF 2 :Eu scintillator has been observed to have an absolute efficiency of 0.1% when exposed to 5-MeV accelerator-generated neutrons (where the absolute efficiency is the ratio of observed neutron events divided by the number of fast neutrons striking the detector)

  3. Phosphor scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1980-01-01

    A method of fabricating scintillators is described in which the phosphor is distributed within the structure in such a way as to enhance the escape of the visible wavelength radiation that would otherwise be dissipated within the scintillator body. Two embodiments of the present invention are disclosed: one in which the phosphor is distributed in a layered structure and another in which the phosphor is dispersed throughout a transparent matrix. (U.K.)

  4. Scintillation neutron detector with dynamic threshold

    International Nuclear Information System (INIS)

    Kornilov, N.; Massey, T.; Grimes, S.

    2014-01-01

    Scintillation neutron detectors with hydrogen are a common tool for neutron spectroscopy. They provide good time resolution, neutron-gamma discrimination and high efficiency of neutron counting. The real open problems connected with application of these detectors are in the energy range >10 MeV. There are no standard neutron spectra known with high accuracy for this energy range. Therefore, traditional methods for experimental investigation of the efficiency function fail for these neutrons. The Monte Carlo simulation cannot provide reasonable accuracy due to unknown characteristics of the reactions for charged particle production (p, α and so on, light output, reaction cross-sections). The application of fission chamber with fissile material as a neutron detector did not help to solve the problem. We may avoid many problems if we use the traditional neutron detector with non-traditional data analysis. In this report we give main relations, and demonstrate the method for Cf-source. Experimental detector efficiency is compared with MC simulation. (authors)

  5. Characteristics of plastic scintillators fabricated by a polymerization reaction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Ho; Son, Jaebum; Kim, Tae Hoon; Kim, Yong Kyun [Dept. of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of)

    2017-04-15

    Three plastic scintillators of 4.5 cm diameter and 2.5-cm length were fabricated for comparison with commercial plastic scintillators using polymerization of the styrene monomer 2.5-diphenyloxazole (PPO) and 1,4-bis benzene (POPOP). Their maximum emission wavelengths were determined at 426.06 nm, 426.06 nm, and 425.00 nm with a standard error of 0.2% using a Varian spectrophotometer (Agilent, Santa Clara, CA, USA). Compton edge spectra were measured using three gamma ray sources [i.e., cesium 137 ({sup 137}Cs), sodium 22 ({sup 22}Na), and cobalt 60 ({sup 60}Co)]. Energy was calibrated by analyzing the Compton edge spectra. The fabricated scintillators possessed more than 99.7% energy linearity. Light output was comparable to that of the BC-408 scintillator (Saint-Gobain, Paris, France). The fabricated scintillators showed a light output of approximately 59–64% of that of the BC-408 scintillator.

  6. Scintillating properties of frozen new liquid scintillators

    CERN Document Server

    Britvich, G I; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    The light emission from scintillators which are liquid at room temperature was studied in the interval between $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C, where the phase transition from liquid to solid takes place. The light yield measured at $-120$~$^{\\circ}$C is about twice as much as that observed at $+20$~$^{\\circ}$C. By cooling the scintillator from $+20$~$^{\\circ}$C to $-120$~$^{\\circ}$C and then heating it from $-120$~$^{\\circ}$C to $+20$~$^{\\circ}$C, the light yield varies in steps at well defined temperatures, which are different for the cooling and heating processes. These hysteresis phenomena appear to be related to the solvent rather than to the dopant. The decay time of scintillation light was measured at $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C. Whilst at room temperature most of the light is emitted with a decay time of 6--8 ns, at $-120$~$^{\\circ}$C a slower component, with a decay time of 25--35 ns, becomes important.

  7. The use of comparative 137Cs body burden estimates from environmental data/models and whole body counting to evaluate diet models for the ingestion pathway

    International Nuclear Information System (INIS)

    Robison, W.L.; Sun, C.

    1997-01-01

    Rongelap and Utirik Atolls were contaminated on 1 March 1954, by a U.S. nuclear test at Bikini Atoll code named BRAVO. The people at both atolls were removed from their atolls in the first few days after the detonation and were returned to their atolls at different times. Detailed studies have been carried out over the years by Lawrence Livermore National Laboratory (LLNL) to determine the radiological conditions at the atolls and estimate the doses to the populations. The contribution of each exposure pathway and radionuclide have been evaluated. All dose assessments show that the major potential contribution to the estimated dose is 137 Cs uptake via the terrestrial food chain. Brookhaven National Laboratory (BNL) has carried out an extensive whole body counting program at both atolls over several years to directly measure the 137 Cs body burden. Here we compare the estimates of the body burdens from the LLNL environmental method with body burdens measured by the BNL whole body counting method. The combination of the results from both methods is used to evaluate proposed diet models to establish more realistic dose assessments. Very good agreement is achieved between the two methods with a diet model that includes both local and imported foods. Other diet models greatly overestimate the body burdens (i.e., dose) observed by whole body counting. The upper 95% confidence limit of interindividual variability around the population mean value based on the environmental method is similar to that calculated from direct measurement by whole body counting. Moreover, the uncertainty in the population mean value based on the environmental method is in very good agreement with the whole body counting data. This provides additional confidence in extrapolating the estimated doses calculated by the environmental method to other islands and atolls. 46 refs., 8 figs., 5 tabs

  8. Composition for use in scintillator systems

    International Nuclear Information System (INIS)

    Tarkkanen, V.

    1976-01-01

    Reference is made to compositions for liquid scintillation counting of aqueous radioactive samples. A composition is described that reduces chemiluminescence on the addition of an alkaline material. Many common sample materials, for example body fluids, are inherently alkaline, whilst samples such as animal tissues are often dissolved in alkaline media. Another problem is water miscibility, and the object is to provide a scintillation counting composition that, when mixed with an aqueous sample, produces a single phase low viscosity mixture over a wide range of water contents and temperatures. The composition described includes a major amount of an aromatic hydrocarbon solvent, a minor amount of an ethoxylated alkyl phenol surfactant, a scintillation solute, an amount of a substituted ethoxylated carboxylic acid sufficient to reduce chemiluminescence, and an amount of a tertiary amine salt or a quaternary ammonium salt of the substituted ethoxylated carboxylic acid sufficient to enhance the water miscibility. The hydrocarbon solvent and the surfactant may be pre-treated with a reactive solid metal hydride to remove peroxides, and then subsequently pre-treated with SO 2 . Examples of the use of the composition are given. (U.K)

  9. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  10. Liquid scintillation cocktails comparison for tritium contamination measurements

    International Nuclear Information System (INIS)

    Bazzarri, S.; Belloni, P.

    1996-01-01

    Liquid scintillation counting is one of the most used techniques for the measurements of tritium contamination. Until few years ago a problem related to this kind of measurement was the potential toxicity of the liquid cocktails used to produce the required scintillation. Some new products that guarantee an almost negligible impact on the environment and that are no longer toxic for the operators are now available. Some of this new scintillation cocktail are suitable to be used for tritium measurement. Due to the great benefit from the health point of view of these new materials a test of their scintillation performance has been done at the ENEA centers to select the product having the best characteristics for tritium measurement. (author)

  11. Low level liquid scintillation analysis for environmental and biomedical quantitation

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1991-01-01

    Over the past five years low level liquid scintillation counting has become increasing popular because of the large number of applications which can be performed using this technique. These applications include environmental monitoring ( 3 H, 90 Sr/ 90 Y, etc.), radiocarbon dating (for age determination to 50,000 years), food adulteration studies (alcohol and beverage industries), radon monitoring (air/water), nuclear power plant monitoring (low level 3 H) and metabolism studies (pharmaceutical research). These applications can be performed with either a dedicated low level LSC or using a standard liquid scintillation counter in conjunction with the new technique of time-resolved LSC (TR-LSC). This technique when used on a standard LSC reduces the instrument background without substantially effecting the background, thus increasing the performance (E 2 /B) of the LSC. Data will be presented for each of the applications mentioned above, comparing the standard LSC and the new TR-LSC techniques. The optimization of the samples for each of these applications will be explored in detail with experimental results. In conclusion, by using the TR-LSC technique in conjunction with a standard LSC the performance of the standard LSC can be increased substantially without dedicating the LSC to doing only low level samples

  12. Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhikov, V.; Grinyov, B.; Piven, L.; Onyshchenko, G.; Sidletskiy, O. [Institute for Scintillation Materials of the NAS of Ukraine, Kharkov, (Ukraine); Naydenov, S. [Institute for Single Crystals of the National Academy of Sciences of Ukraine, Kharkov, (Ukraine); Pochet, T. [DETEC-Europe, Vannes (France); Smith, C. [Naval Postgraduate School, Monterey, CA (United States)

    2015-07-01

    It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n

  13. Design, building and evaluation of a neutron detection device based on boron loaded plastic scintillator

    International Nuclear Information System (INIS)

    Normand, St.

    2001-10-01

    This work focuses on the study, the characterization and the fabrication of Boron-loaded plastic scintillators. Their use in thermal and fast neutron detection devices is also investigated. Fabrication process, especially boron doping, is explained in the first part of this work. Several FTIR, UV-visible and NMR analysis methods were used in order to characterize the material and to check its structure and stoichiometry. Experiences were done using alpha particles and proton beams to measure the scintillation characteristics. Light emission could therefore be completely determined by the Birks semi-empirical relation. In the second part, the whole detector simulation is undergone: interaction between material and radiation, light generation, paths and signal generation. Neutron simulation by MCNP (Monte Carlo N-Particles) is coupled to a light generation and propagation code developed especially during this work. These simulation tools allow us to optimize the detector geometry for neutron detection and to determine the geometry influence to the photon collection efficiency. Neutron detection efficiency and mean lifetime in this scintillator are also simulated. The close fit obtained between experimental measurements and simulations demonstrate the reliability of the method used. The third part deals with the discrimination methods between neutron and gamma, such as analog (zero crossing) and digital (charge comparison) ones. Their performances were explained and compared. The last part of this work reports on few applications where neutron detection is essential and can be improved with the use of boron loaded plastic scintillators. In particular, the cases of doped scintillation fibers, neutron spectrometry devices and more over neutron multiplicity counting devices are presented. (author)

  14. Characterization and development of an active scintillating target for nuclear reaction studies on actinides

    Energy Technology Data Exchange (ETDEWEB)

    Belier, Gilbert, E-mail: gilbert.belier@cea.fr [CEA, DAM, DIF, DPTA, Centre du Grand Rue, 91297 Arpajon (France); Aupiais, Jean; Varignon, Cyril; Vayre, Sylvain [CEA, DAM, DIF, DPTA, Centre du Grand Rue, 91297 Arpajon (France)

    2012-02-01

    This article presents the development of a new kind of active actinide target, based on organic liquid scintillators containing the dissolved isotope. Amongst many advantages one can mention the very high detection efficiency, the Pulse Shape Discrimination capability, the fast response allowing high count rates and good time resolution and the ease of fabrication. The response of this target to fission fragments has been studied. The discrimination of alpha, fission and proton recoil events is demonstrated. The alpha decay and fission detection efficiencies are simulated and compared to measurements. Finally the use of such a target in the context of fast neutron induced reactions is discussed.

  15. Characterization and development of an active scintillating target for nuclear reaction studies on actinides

    International Nuclear Information System (INIS)

    Belier, Gilbert; Aupiais, Jean; Varignon, Cyril; Vayre, Sylvain

    2012-01-01

    This article presents the development of a new kind of active actinide target, based on organic liquid scintillators containing the dissolved isotope. Amongst many advantages one can mention the very high detection efficiency, the Pulse Shape Discrimination capability, the fast response allowing high count rates and good time resolution and the ease of fabrication. The response of this target to fission fragments has been studied. The discrimination of alpha, fission and proton recoil events is demonstrated. The alpha decay and fission detection efficiencies are simulated and compared to measurements. Finally the use of such a target in the context of fast neutron induced reactions is discussed.

  16. Systematic studies of small scintillators for new sampling calorimeter

    International Nuclear Information System (INIS)

    Jacosalem, E.P.; Sanchez, A.L.C.; Bacala, A.M.; Iba, S.; Nakajima, N.; Ono, H.; Miyata, H.

    2007-01-01

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R and D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are systematically studied. The scintillation light due to beta rays from a collimated 90 Sr source are collected from the scintillator by wavelength-shifting (WLS) fiber and converted into electrical signals at the PMT. The wrapped scintillator that gives the best light yield is determined by comparing the measured pulse height of each 10 x 40 x 2 mm strip scintillator covered with 3M reflective mirror film, teflon, white paint, black tape, gold, aluminum and white paint+teflon. The pulse height dependence on position, length and thickness of the 3M reflective mirror film and teflon wrapped scintillators are measured. Results show that the 3M radiant mirror film-wrapped scintillator has the greatest light yield with an average of 9.2 photoelectrons. It is observed that light yield slightly increases with scintillator length, but increases to about 100% when WLS fiber diameter is increased from 1.0 mm to 1.6 mm. The position dependence measurement along the strip scintillator showed the uniformity of light transmission from the sensor to the PMT. A dip across the strip is observed which is 40% of the maximum pulse height. The block type scintillator pulse height, on the other hand, is found to be almost proportional to scintillator thickness. (author)

  17. Elevator mechanism and method for scintillation detectors

    International Nuclear Information System (INIS)

    Frank, E.

    1975-01-01

    An elevator mechanism and method for raising and lowering radioactive samples through a shielded vertical counting chamber in a benchtop scintillation detector is described. The elevator mechanism adds little or nothing to the height of the detector by using an elongated flexible member such as a metal tape secured to the bottom of the elevator platform and extending downwardly through the counting chamber and its bottom shielding, where the tape is bent laterally for connection to a drive means. In the particular embodiment illustrated, the tape is bent laterally below the bottom shielding for the counting chamber, and then upwardly along or through one side of the shielding to a reel at the top of the shielding. The tape is wound onto the reel, and the reel is driven by a reversible motor which winds and unwinds the tape on the reel to raise and lower the elevator platform

  18. Background characterization in a liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos, J.M.; Jimenez de Mingo, A.

    1995-01-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0 - 20 KeV, 0 - 800 KeV and 0 - 2 MeV, for volume between 2 and 20 mi of three commercial scintillators, Hisafe II, Ultima-Gold and Instagel, and quenching degree in the interval equivalent to 50% - 3% tritium efficiency. This procedure was tested with standard samples of 3H, and led to average discrepancies less than 10% for activity ≥0,6 Bq, against conventional methods for which the discrepancies are twice on average. (Author) 10 refs

  19. Background characterization in a liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los arcos, J.M.; Jimenez de Mingo, A.

    1995-01-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0-20 KeV, 0-800 KeV and 0-2 MeV, for volume between 2 and 20 ml of three commercial scintillators, Hisafe II, Ultima-gold and Instagel, and quenching degree in the interval equivalent to 50%-3% tritium efficiency. This procedure was tested with standard samples of ''3 H, and led to average discrepancies less than 10% for activity => 0,6 Bq, against conventional methods for which the discrepancies are twice on average

  20. Liquid scintillation alpha particle spectrometry. Progress report

    International Nuclear Information System (INIS)

    Bell, L.L.; Hakooz, S.A.; Johnson, L.O.; Nieschmidt, E.B.; Meikrantz, D.H.

    1979-12-01

    Objective to develop a technique whereby Pu may be put into solution, extracted by solvent extraction into a suitable extractive scintillant and subsequently counted. Presented here are results of attempts to separate beta and alpha activities through pulse shape discrimination. A qualitative discussion is given which yields alpha particle peak widths, resolution and response. The detection efficiency for alpha particles in a liquid scintillant is 100%. Present detection sensitivities of the equipment being used are: 4.5 x 10 -6 μCi (100 s), 1.2 x 10 -6 μCi (1000 s), and 4.0 x 10 -7 μCi (10,000 s) at the 3 sigma level. The detectability of a particular alpha-emitting species is strongly dependent upon the population of other species. The ability to discriminate depends upon the system resolution. 14 figures, 2 tables

  1. Characterization of plastic scintillators for detection of radioactivity: Light yield, Time decay measurements and Neutron/γ Pulse Shape Discrimination

    International Nuclear Information System (INIS)

    Montbarbon, E.; Pansu, R.B.; Hamel, M.; Coulon, R.

    2015-07-01

    Since Helium-3 shortage, organic scintillators play a major role in neutron detection. CEA LIST decided to focus on plastic scintillators. By definition, a plastic scintillator is a radio-luminescent polymer; this means that it emits light after interaction with an ionizing radiation. A platform was developed to characterize lab-made prepared scintillators and to compare them with commercial scintillators. Three physicochemical criteria are determined with this unique platform. (authors)

  2. Comparative study of optical and scintillation properties of YVO{sub 4}, (Lu{sub 0.5}Y{sub 0.5})VO{sub 4}, and LuVO{sub 4} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Yutaka, E-mail: fuji-you@tagen.tohoku.ac.j [IMRAM, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Yanagida, Takayuki; Yokota, Yuui; Chani, Valery [IMRAM, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Kochurikhin, Vladimir V. [General Physics Institute, 38 Vavilov Street, 119991, Federation, Moscow (Russian Federation); Yoshikawa, Akira [IMRAM, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); NICHe, Tohoku University, 6-6-10 Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan)

    2011-04-11

    Optical and scintillation properties of YVO{sub 4}, (Lu{sub 0.5}Y{sub 0.5})VO{sub 4}, and LuVO{sub 4} single crystals grown by the Czochralski (CZ) method with RF heating system are compared. All vanadate crystals show high transmittance ({approx}80%) in the 400-900 nm wavelength range. In both photo- and radio-luminescence spectra, intense peak around 400-500 nm, which was ascribed to the transition from triplet state of VO{sub 4}{sup 3-}, was clearly observed. The main decay time component was about 38 {mu}s (YVO{sub 4}), 18 {mu}s ((Lu{sub 0.5}Y{sub 0.5})VO{sub 4}), and 17 {mu}s (LuVO{sub 4}) under 340 nm excitation. The scintillation light yields of YVO{sub 4}, (Lu{sub 0.5}Y{sub 0.5})VO{sub 4}, and LuVO{sub 4} crystals (obtained from the {sup 137}Cs excited pulse height spectra) were evaluated to be about 11,200, 10,700, and 10,300 ph/MeV, respectively.

  3. Alpha/beta separation in liquid scintillation gel samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1994-01-01

    The pulse shape analysis commonly used in liquid scintillation alpha/beta separations is satisfactory for moderate quench levels. However, for gel samples, the alpha particle counting efficiency is never greater than 10%, and an optimum separation of the alpha component cannot be achieved when beta to alpha counting rate ratios are greater than 100. In such cases, it is better to use a spectrum analysis method for alpha/beta separation. ((orig.))

  4. Gross beta determination in drinking water using scintillating fiber array detector.

    Science.gov (United States)

    Lv, Wen-Hui; Yi, Hong-Chang; Liu, Tong-Qing; Zeng, Zhi; Li, Jun-Li; Zhang, Hui; Ma, Hao

    2018-04-04

    A scintillating fiber array detector for measuring gross beta counting is developed to monitor the real-time radioactivity in drinking water. The detector, placed in a stainless-steel tank, consists of 1096 scintillating fibers, both sides of which are connected to a photomultiplier tube. The detector parameters, including working voltage, background counting rate and stability, are tested, and the detection efficiency is calibrated using standard potassium chloride solution. Water samples are measured with the detector and the results are compared with those by evaporation method. The results show consistency with those by evaporation method. The background counting rate of the detector is 38.131 ± 0.005 cps, and the detection efficiency for β particles is 0.37 ± 0.01 cps/(Bq/l). The MDAC of this system can be less than 1.0 Bq/l for β particles in 120 min without pre-concentration. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Biomarkers of Progression after HIV Acute/Early Infection: Nothing Compares to CD4+ T-cell Count?

    Directory of Open Access Journals (Sweden)

    Gabriela Turk

    2018-01-01

    Full Text Available Progression of HIV infection is variable among individuals, and definition disease progression biomarkers is still needed. Here, we aimed to categorize the predictive potential of several variables using feature selection methods and decision trees. A total of seventy-five treatment-naïve subjects were enrolled during acute/early HIV infection. CD4+ T-cell counts (CD4TC and viral load (VL levels were determined at enrollment and for one year. Immune activation, HIV-specific immune response, Human Leukocyte Antigen (HLA and C-C chemokine receptor type 5 (CCR5 genotypes, and plasma levels of 39 cytokines were determined. Data were analyzed by machine learning and non-parametric methods. Variable hierarchization was performed by Weka correlation-based feature selection and J48 decision tree. Plasma interleukin (IL-10, interferon gamma-induced protein (IP-10, soluble IL-2 receptor alpha (sIL-2Rα and tumor necrosis factor alpha (TNF-α levels correlated directly with baseline VL, whereas IL-2, TNF-α, fibroblast growth factor (FGF-2 and macrophage inflammatory protein (MIP-1β correlated directly with CD4+ T-cell activation (p < 0.05. However, none of these cytokines had good predictive values to distinguish “progressors” from “non-progressors”. Similarly, immune activation, HIV-specific immune responses and HLA/CCR5 genotypes had low discrimination power. Baseline CD4TC was the most potent discerning variable with a cut-off of 438 cells/μL (accuracy = 0.93, κ-Cohen = 0.85. Limited discerning power of the other factors might be related to frequency, variability and/or sampling time. Future studies based on decision trees to identify biomarkers of post-treatment control are warrantied.

  6. Evaluation of safe use of 188Re-HEDP comparing urine data and whole body counting in gamma camera

    International Nuclear Information System (INIS)

    Paolino, Andrea; Teran, Mariella; Savio, Eduardo; Coppe, Fatima; Lopez, Andrea; Hermida, Juan C.; Gaudiano, Javier

    2008-01-01

    Cancer is the second more frequent cause of death, after cardiovascular disease, in developing countries. Most of adult patients with neoplasms will develop skeletal metastases that can lead to progressive pain. 188 Re emits both beta particles suitable for therapy and a gamma ray (155 keV), adequate for diagnostic imaging in order to verify localization in the pain areas associated to metastatic process. The aim of this work was to correlate 188 Re-HEDP dose estimations using biological samples and direct measures. All the patients had breast or prostate cancer, with bone metastases. Each patient received a tracer dose of 185 MBq of radiopharmaceutical. Urine samples were collected at 0-1, 1-2, 2-4 and, 4-6 hours post administration, and measured in dose calibrator. Whole body counts were acquired using a camera without collimator, window centered at 155 KeV, matrix 256 x 256, during 60 seconds. Data were obtained at 1 and 6 hours post administration with the patient in sitting position at 2 meter from the detector. Percentage of injected dose was calculated both for urine samples and image for each patient. The number of disintegrations was determined for organs in which higher concentration of activity was observed: those involved in the excretion, red marrow and the reminder of the body. Total doses were estimated using OLINDA/EXM software. Conclusions: Data showed that the organs chosen as more compromised during the tracer dose procedure received very low effective doses. A good correlation between calculations performed both for image and urine samples was obtained. Safety of the radiopharmaceutical was also verified using this method. (author)

  7. Inorganic liquid scintillator

    International Nuclear Information System (INIS)

    Pavlicek, Z.; Barta, C.; Jursova, L.

    1986-01-01

    An inorganic liquid scintillator is designed which contains 1 to 30 wt.% of an inorganic molecular compound as the basic active component; the compound contains a cation with an atomic number higher than 47 and a halogen anion. The basic inorganic component is dissolved in water or in an organic solvent in form of non-dissociated molecules or self-complexes in which the bond is preserved between the cation and anion components. The light yield from these scintillators ranges between 70 and 150% of the light yield of a standard organic scintillator based on toluene. They are advantageous in that that they allow to increase the water content in the sample to up to 100%. (M.D.)

  8. Physics of scintillation detectors

    International Nuclear Information System (INIS)

    Novotny, R.

    1991-01-01

    The general concept of a radiation detector is based on three fundamental principles: sensitivity of the device to the radiation of interest which requires a large cross-section in the detector material, detector response function to the physical properties of the radiation. As an example, a scintillation detector for charged particles should allow to identify the charge of the particle, its kinetic energy and the time of impact combined with optimum resolutions. Optimum conversion of the detector response (like luminescence of a scintillator) into electronical signals for further processing. The following article will concentrate on the various aspects of the first two listed principles as far as they appear to be relevant for photon and charged particle detection using organic and inorganic scintillation detectors. (orig.)

  9. Scintillator plate calorimetry

    International Nuclear Information System (INIS)

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin

  10. Microfluidic Scintillation Detectors

    CERN Multimedia

    Microfluidic scintillation detectors are devices of recent introduction for the detection of high energy particles, developed within the EP-DT group at CERN. Most of the interest for such technology comes from the use of liquid scintillators, which entails the possibility of changing the active material in the detector, leading to an increased radiation resistance. This feature, together with the high spatial resolution and low thickness deriving from the microfabrication techniques used to manufacture such devices, is desirable not only in instrumentation for high energy physics experiments but also in medical detectors such as beam monitors for hadron therapy.

  11. The development of a high-resolution scintillating fiber tracker with silicon photomultiplier readout

    International Nuclear Information System (INIS)

    Roper Yearwood, Gregorio

    2013-01-01

    In this work I present the design and test results for a novel, modular tracking detector from scintillating fibers which are read out by silicon photomultiplier (SiPM) arrays. The detector modules consist of 0.25 mm thin scintillating fibers which are closely packed in five-layer ribbons. Two ribbons are fixed to both sides of a carbon-fiber composite structure. Custom made SiPM arrays with a photo-detection efficiency of about 50% read out the fibers. Several 860 mm long and 32 mm wide tracker modules were tested in a secondary 12 GeV/c beam at the PS facilities, CERN in November of 2009. During this test a spatial resolution better than 0.05 mm at an average light yield of about 20 photons for a minimum ionizing particle was determined. This work details the characterization of scintillating fibers and silicon photomultipliers of different make and model. It gives an overview of the production of scintillating fiber modules. The behavior of detector modules during the test-beam is analyzed in detail and different options for the front-end electronics are compared. Furthermore, the implementation of the proposed tracking detector from scintillating fibers within the scope of the PERDaix experiment is discussed. The PERDaix detector is a permanent magnet spectrometer with a weight of 40 kg. It consists of 8 tracking detector layers from scintillating fibers, a time-of-flight detector from plastic scintillator bars with silicon photomultiplier readout and a transition radiation detector from an irregular fleece radiator and Xe/CO 2 filled proportional counting tubes. The PERDaix detector was launched with a helium balloon within the scope of the ''Balloon-Experiments for University Students'' (BEXUS) program from Kiruna, Sweden in November 2010. For a few hours PERDaix reached an altitude of 33 km and measured cosmic rays. In May 2011, the PERDaix detector was characterized during a test-beam at the PS-facilities at CERN. This work introduces methods for event

  12. Counting efficiency formulae for two, three or four photomultiplier systems

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1993-01-01

    Counting efficiency formulae as a function of the non-detection probability and the electron distributions for systems with two, three or dour photomultipliers are obtained in this paper. It is assumed that the photocathode electron emission follows the Poisson distribution. The obtained formulae are basic to compute the counting efficiency in liquid scintillation spectrometers

  13. Scintillation properties of polycrystalline LaxY1-xO3 ceramic

    Science.gov (United States)

    Sahi, Sunil; Chen, Wei; Kenarangui, Rasool

    2015-03-01

    Scintillators are the material that absorbs the high-energy photons and emits visible photons. Scintillators are commonly used in radiation detector for security, medical imaging, industrial applications and high energy physics research. Two main types of scintillators are inorganic single crystals and organic (plastic or liquid) scintillators. Inorganic single crystals are expensive and difficult to grow in desire shape and size. Also, some efficient inorganic scintillator such as NaI and CsI are not environmental friendly. But on the other hand, organic scintillators have low density and hence poor energy resolution which limits their use in gamma spectroscopy. Polycrystalline ceramic can be a cost effective alternative to expensive inorganic single crystal scintillators. Here we have fabricated La0.2Y1.8O3 ceramic scintillator and studied their luminescence and scintillation properties. Ceramic scintillators were fabricated by vacuum sintering of La0.2Y1.8O3 nanoparticles at temperature below the melting point. La0.2Y1.8O3 ceramic were characterized structurally using XRD and TEM. Photoluminescence and radioluminescence studies were done using UV and X-ray as an excitation source. We have used gamma isotopes with different energy to studies the scintillation properties of La0.2Y1.8O3 scintillator. Preliminary studies of La0.2Y1.8O3 scintillator shows promising result with energy resolution comparable to that of NaI and CsI.

  14. Scintillation properties of acrylate based plastic scintillator by photoploymerization method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hwan [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Lee, Joo Il [Dept. of of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima GoldTM LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380⁓520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400⁓ 800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

  15. Performance comparison of scintillators for alpha particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Yuki [Graduate School of Medicine, Nagoya University, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya, Aichi 461-8673 (Japan); Japan Atomic Energy Agency, Muramatsu 4-33, Tokai-mura, Ibaraki 319-1194 (Japan); Yamamoto, Seiichi [Graduate School of Medicine, Nagoya University, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya, Aichi 461-8673 (Japan); Izaki, Kenji [Japan Atomic Energy Agency, Muramatsu 4-33, Tokai-mura, Ibaraki 319-1194 (Japan); Kaneko, Junichi H.; Toui, Kohei; Tsubota, Youichi; Higuchi, Mikio [Graduate School of Engineering, Hokkaido University, Kita 13, Nishi 8, Kita-ku, Sapporo, Hokkaido 060-8628 (Japan)

    2014-11-11

    Scintillation detectors for alpha particles are often used in nuclear fuel facilities. Alpha particle detectors have also become important in the research field of radionuclide therapy using alpha emitters. ZnS(Ag) is the most often used scintillator for alpha particle detectors because its light output is high. However, the energy resolution of ZnS(Ag)-based scintillation detectors is poor because they are not transparent. A new ceramic sample, namely the cerium doped Gd{sub 2}Si{sub 2}O{sub 7} (GPS) scintillator, has been tested as alpha particle detector and its performances have been compared to that one of three different scintillating materials: ZnS(Ag), GAGG and a standard plastic scintillator. The different scintillating materials have been coupled to two different photodetectors, namely a photomultiplier tube (PMT) and a Silicon Photo-multiplier (Si-PM): the performances of each detection system have been compared. Promising results as far as the energy resolution performances (10% with PMT and 14% with Si-PM) have been obtained in the case of GPS and GAGG samples. Considering the quantum efficiencies of the photodetectors under test and their relation to the emission wavelength of the different scintillators, the best results were achieved coupling the GPS with the PMT and the GAGG with the Si-PM.

  16. Polysiloxane scintillator composition

    Science.gov (United States)

    Walker, J.K.

    1992-05-05

    A plastic scintillator useful for detecting ionizing radiation comprising a matrix which comprises an optically transparent polysiloxane having incorporated therein at least one ionizing radiation-hard fluor capable of converting electromagnetic energy produced in the polysiloxane upon absorption of ionizing radiation to detectable light.

  17. WORKSHOP: Scintillating crystals

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-12-15

    Scintillating crystals are one of the big spinoff success stories of particle physics, and from 22-26 September an international workshop in Chamonix in the French Alps looked at the increasing role of these materials in pure and applied science and in industry.

  18. Radiopharmaceuticals for bone scintillators

    International Nuclear Information System (INIS)

    Rey, A.M.

    1994-01-01

    One of the diagnostic techniques used in nuclear medicine is the bone scintiscanning with labelled compounds for obtain skeletal images. The main sections in this work are: (1) bone composition and anatomy;(2)skeletal radiopharmaceutical development;(3)physical properties of radionuclides;(4)biological behaviour and chemical structures;(5)radiopharmaceuticals production for skeletal scintillation;(6)kits;(7)dosimetry and toxicity.tabs

  19. WORKSHOP: Scintillating crystals

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Scintillating crystals are one of the big spinoff success stories of particle physics, and from 22-26 September an international workshop in Chamonix in the French Alps looked at the increasing role of these materials in pure and applied science and in industry

  20. Economical stabilized scintillation detector

    International Nuclear Information System (INIS)

    Anshakov, O.M.; Chudakov, V.A.; Gurinovich, V.I.

    1983-01-01

    An economical scintillation detector with the stabilization system of an integral type is described. Power consumed by the photomultiplier high-voltage power source is 40 mW, energy resolution is not worse than 9%. The given detector is used in a reference detector of a digital radioisotope densimeter for light media which is successfully operating for several years

  1. Uranium-scintillator device

    International Nuclear Information System (INIS)

    Smith, S.D.

    1979-01-01

    The calorimeter subgroup of the 1977 ISABELLE Summer Workshop strongly recommended investigation of the uranium-scintillator device because of its several attractive features: (1) increased resolution for hadronic energy, (2) fast time response, (3) high density (i.e., 16 cm of calorimeter per interaction length), and, in comparison with uranium--liquid argon detectors, (4) ease of construction, (5) simple electronics, and (6) lower cost. The AFM group at the CERN ISR became interested in such a calorimeter for substantially the same reasons, and in the fall of 1977 carried out tests on a uranium-scintillator (U-Sc) calorimeter with the same uranium plates used in their 1974 studies of the uranium--liquid argon (U-LA) calorimeter. The chief disadvantage of the scintillator test was that the uranium plates were too small to fully contain the hadronic showers. However, since the scintillator and liquid argon tests were made with the plates, direct comparison of the two types of devices could be made

  2. Microvessel density compared with the Chalkley count in a prognostic study of angiogenesis in breast cancer patients

    DEFF Research Database (Denmark)

    Hansen, S; Sørensen, F B; Vach, W

    2004-01-01

    Evaluation of angiogenesis by intratumoral vessel profiles can be performed by different methods. The aim of this study was to investigate the prognostic value of estimates obtained by the intratumoral microvessel density (MVD) method and then to compare with corresponding estimates obtained...

  3. Performance of molded plastic scintillators

    International Nuclear Information System (INIS)

    Gen, N.S.; Leman, V.E.; Solomonov, V.M.

    1989-01-01

    The performance of molded plastic scintillators is studied. The plastic scintillators studied were formed by transfer molding and intrusion from a scintillation composition consisting of polystyrene and a standard system of luminescent additives: 2 mass % of paraterphenyl + 0.06 mass % 1,4-di-/2-[5-phenyloxazoyly]/benzene and a plasticizer. The combined effect of mechanical load and temperature was studied. The effect of radiation on molded plastic scintillators was studied using gamma radiation from a 60 Co source. The studies show that the main operating characteristics of molded plastic scintillators are on a par with those of polymerized plastic scintillators. At the same time, molded plastic scintillators are superior in thermal stability at temperatures below the glass transition temperature and with respect to their working temperature range

  4. Neutron energy response measurement of scintillation detectors

    International Nuclear Information System (INIS)

    Yang Hongqiong; Peng Taiping; Yang Jianlun; Tang Zhengyuan; Yang Gaozhao; Li Linbo; Hu Mengchun; Wang Zhentong; Zhang Jianhua; Li Zhongbao; Wang Lizong

    2004-01-01

    Neutron sensitivities of detectors composed of plastic scintillator ST401, ST1422, ST1423 and phyotomultiplier tube in primary energy range of fission neutron are calibrated by direct current. The energy response curve of the detectors is obtained in this experiment. The experimental result has been compared with the theoretical calculation and they are in agreement within measuring uncertainty. (authors)

  5. Ultra Low Level Tritium Analysis Method Using a Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, S. J.; Kim, H. J.; Kim, H.; Lim, H. J.; Lee, M. W.; Jeong, D. H.; Kim, J. K.; Kang, Y. R. [Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, S. H. [Inje University, Gimhae, (Korea, Republic of)

    2015-05-15

    To evaluate {sup 3}H concentration in the atmosphere more accurately compared to the conventional methods, the author of this paper intended to suggest more improved analytical methods and derived the elements which might occur during analysis or required improvements. The method suggested in this study is able to reduce the uncertainty and errors which may be existent in evaluating the {sup 3}H concentration of environmental sample s and thus will serve as the best solution in the technical and economic point of view. Liquid Scintillation Counter is the most widely used to analyze ultra-low level {sup 3}H by using CPM / DPM Counting Mode using external radiation source and Spectrum Plot Mode using internal radiation source. In CPM / DPM Counting Mode, multiple samples can be measured by single calibration despite its rather higher background whereas Spectrum Plot Mode requires more time and cost to analyze multiple samples despite its reliability to reduce the contribution of other radionuclides.

  6. Optimization of the detector and associated electronics used for high-resolution liquid-scintillation alpha spectroscopy

    International Nuclear Information System (INIS)

    Thorngate, J.H.; Christian, D.J.

    1977-01-01

    The performance of various reflector geometries, light coupling liquids, photomultiplier tubes, preamplifiers and linear amplifiers were compared and the configuration found that optimized the combination of pulse-height resolution and pulse-shape discrimination. The best combination used a hemispherical reflector, filled with distilled water, coupled to an 8575 photomultiplier tube, the output of which was conditioned by a special integrating preamplifier and a double-delay-line linear amplifier. Careful choice of the scintillator, sample preparation procedures, and electronic apparatus can produce liquid-scintillation alpha spectroscopy with a pulse-height resolution of 300 keV, or less, and, by using pulse-shape discrimination, background levels as low as 0.01 counts/min. (author)

  7. Performance evaluation of GPS receiver under equatorial scintillation

    Directory of Open Access Journals (Sweden)

    Alison de Oliveira Moraes

    2009-06-01

    Full Text Available Equatorial scintillation is a phenomenon that occurs daily in the equatorial region after the sunset and affects radio signals that propagate through the ionosphere. Depending on the temporal and spatial situation, equatorial scintillation can represent a problem in the availability and precision of the Global Positioning System (GPS. This work is concerned with evaluating the impact of equatorial scintillation on the performance of GPS receivers. First, the morphology and statistical model of equatorial scintillation is briefly presented. A numerical model that generates synthetic scintillation data to simulate the effects of equatorial scintillation is presented. An overview of the main theoretical principles on GPS receivers is presented. The analytical models that describe the effects of scintillation at receiver level are presented and compared with numerical simulations using a radio software receiver and synthetic data. The results achieved by simulation agreed quite well with those predicted by the analytical models. The only exception is for links with extreme levels of scintillation and when weak signals are received.

  8. New scintillating crystals for PET scanners

    CERN Document Server

    Lecoq, P

    2002-01-01

    Systematic R&D on basic mechanism in inorganic scintillators, initiated by the Crystal Clear Collaboration at CERN 10 years ago, has contributed not to a small amount, to the development of new materials for a new generation of medical imaging devices with increased resolution and sensitivity. The first important requirement for a scintillator to be used in medical imaging devices is the stopping power for the given energy range of X and gamma rays to be considered, and more precisely the conversion efficiency. A high light yield is also mandatory to improve the energy resolution, which is essentially limited by the photostatistics and the electronic noise at these energies. A short scintillation decay time allows to reduce the dead time and therefore to increase the limiting counting rate. When all these requirements are fulfilled the sensitivity and image contrast are increased for a given patient dose, or the dose can be reduced. Examples of new materials under development by the Crystal Clear Collabor...

  9. Characterisation of selenium compounds in rye seedling biomass using {sup 75}Se-labelling/SDS-PAGE separation/{gamma}-scintillation counting, and HPLC-ICP-MS analysis of a range of enzymatic digests

    Energy Technology Data Exchange (ETDEWEB)

    Bryszewska, Malgorzata A. [Technical University of Lodz (Poland). Institute of General Food Chemistry; Ambroziak, Wojciech [Technical University of Lodz (Poland). Institute of Fermentation Technology and Microbiology; Rudzinski, Juliusz [Technical University of Lodz (Poland). Institute of Applied Radiation Chemistry; Lewis, D. John [Central Science Laboratory, York (United Kingdom)

    2005-07-01

    In the present study, selenium-enriched plant biomass was investigated to evaluate the ability of rye seedlings to take up, and assimilate, inorganic selenium. Two different analytical approaches were used. Electrophoretic separation (SDS-PAGE) of proteins extracted from {sup 75}Se-labelled biomass was used to investigate the biotransformation of selenite into organic forms of the element. Ion-pair chromatography coupled with ICP-MS detection was chosen for the analysis of selenium species, enzymatically extracted from the plant biomass. The results of three enzymatic hydrolysis procedures and three sequential enzymatic extractions procedures are compared. The most effective single extraction was proteolysis (using protease type XIV), giving an overall extraction efficiency of 48%. However, for combinations of enzymes, the most effective was cellulase (Trichoderma viride) followed by sequential extraction of the solid pellet using protease type XIV, giving an extraction efficiency of 70%. The complementary data from the electrophoretic fractionation of proteins, and the HPLC separation of Se-species in the proteolytic digests, reveal the existence of large number of selenium-containing compounds in the rye seedling plant biomass. The results showed the complete biotransformation of inorganic selenium into organic forms during germination of the rye seedlings. HPLC-ICP-MS analysis of extracts from the plant biomass did not show the presence of selenate or selenite. At the time of this study, the lack of suitable organic-MS facilities meant that it was not possible to characterise them fully. However, the data does show that a combination of different enzymes, rather than just the commonly-used protease, should be considered when developing an extraction strategy for selenium in different food types to those already reported in the literature. (orig.)

  10. Technology update on fast plastic scintillators for medical applications

    International Nuclear Information System (INIS)

    Lyons, P.B.

    1977-01-01

    Plastic scintillators appear to have potential utility in three research areas related to nuclear medicine: (1) high count rate applications in general, (2) positron camera applications, and (3) positron source localization through measurement of relative arrival times of annihilation quanta at two co-linear detectors. These three areas of applicability depend on improvement in three specific areas of plastic scintillator technology: (a) development of plastics with very fast decay times, (b) development of plastics with greatly improved high energy photon detection efficiencies (high-Z loaded plastics), and (c) improvement of fast timing system capabilities. The three preceding areas of improvement are discussed

  11. Isocount scintillation scanner with preset statistical data reliability

    International Nuclear Information System (INIS)

    Ikebe, J.; Yamaguchi, H.; Nawa, O.A.

    1975-01-01

    A scintillation detector scans an object such as a live body along horizontal straight scanning lines in such a manner that the scintillation detector is stopped at a scanning point during the time interval T required for counting a predetermined number of N pulses. The rate R/sub N/ = N/T is then calculated and the output signal pulses the number of which represents the rate R or the corresponding output signal is used as the recording signal for forming the scintigram. In contrast to the usual scanner, the isocount scanner scans an object stepwise in order to gather data with statistically uniform reliability

  12. Color quench correction for low level Cherenkov counting.

    Science.gov (United States)

    Tsroya, S; Pelled, O; German, U; Marco, R; Katorza, E; Alfassi, Z B

    2009-05-01

    The Cherenkov counting efficiency varies strongly with color quenching, thus correction curves must be used to obtain correct results. The external (152)Eu source of a Quantulus 1220 liquid scintillation counting (LSC) system was used to obtain a quench indicative parameter based on spectra area ratio. A color quench correction curve for aqueous samples containing (90)Sr/(90)Y was prepared. The main advantage of this method over the common spectra indicators is its usefulness also for low level Cherenkov counting.

  13. Experiences that Count: A Comparative Study of the ICTY and SCSL in Shaping the Image of Justice

    Directory of Open Access Journals (Sweden)

    Kristin Xueqin Wu

    2013-01-01

    Full Text Available The legitimacy of international criminal trials is not automatic: it is conditional upon endorsement by local communities. If the very communities involved do not 'feel' a sense of justice, these trials would not only contribute little to the post-conflict peace process, but also create a backlash against these international courts and tribunals, tarnishing the image of international criminal justice. Despite its critical importance, this image management process is still at the stage of trial and error. The first outreach programme, established by the International Criminal Tribunal for the former Yugoslavia (ICTY, has been fighting a losing battle against the Tribunal's poor image in the former Yugoslavia region. In contrast, the Special Court for Sierra Leone (SCSL has been highly praised for promoting a holistic experience of 'just'. What causes these differences, and what could be learnt from them? After comparing the various undertakings by these two ad-hoc tribunals - in terms of outreach strategies, press strategies and resource management - this paper draws three lessons for the permanent International Criminal Court (ICC: gaining acceptance, smoothing communication and boosting judicial efficiency.

  14. Development of NaI(Tl) scintillating films for imaging soft x-rays

    International Nuclear Information System (INIS)

    Shepherd, J.A.

    1993-01-01

    Thin film NaI(Tl) scintillators, of areas of up to 130 cm 2 , have been fabricated and characterized for use on soft x-ray imaging photomultiplier tubes. Relevant parameters of photon-counting imaging detectors are defined and used to predict the performance of several materials, including CsI(Na), CsI(Tl), CaF 2 (Eu), Lu 2 (SiO 4 )O:Ce, and NaI(Tl), as thin film scintillators on fiber optic substrates. Also, x-ray imaging methodologies are compared. The NaI(Tl) films were vapor-deposited onto quartz and fiber optic substrates using a powder flash deposition technique. When compared to single crystal NaI(Tl), the films were found to have equally high light yield but lower energy resolution. Light yield optimization was studied in detail including the effects of substrate temperature, activator concentration in the evaporant, and boat temperature. Spatial resolution as well as parallax errors are discussed and measured for film thicknesses up to 61 μm. A technique is described that can substantially increase the light collection of high index films on fiber optic disks. The light collection was improved by 20% by coating the disk with potassium silicate before the NaI(Tl) deposition. Large area films, up to 130 cm 2 , had a spatial uniformity of response within ±1.5% for count rate and ±3.5% for light yield, and their spatial resolution exceeded 16.6 lp mm -1 when deposited onto fiber optic substrates. The 8-keV x-ray detection efficiency of the microchannel plate imaging photomultiplier tube coupled to a NaI(Tl) film scintillator is predicted to be 88%. Other uses for the films are also described

  15. Inorganic-organic rubbery scintillators

    CERN Document Server

    Gektin, A V; Pogorelova, N; Neicheva, S; Sysoeva, E; Gavrilyuk, V

    2002-01-01

    Spectral-kinetic luminescence properties of films, containing homogeneously dispersed scintillation particles of CsI, CsI:Tl, CsI:Na, and NaI:Tl in optically transparent organosiloxane matrix, are presented. Material is flexible and rubbery and in consequence the detectors of convenient shapes can be produced. It is found that luminescence spectra of the received films are identical whereas decay times are much shorter compared to the same ones of the corresponding single crystals. Layers with pure CsI demonstrate only the fast UV emission (307 nm, 10 ns) without blue microsecond afterglow typical for crystals. The films containing NaI:Tl are non-hygroscopic and preserve scintillation properties for a long time in humid atmosphere unlike single crystals. Organosiloxane layers with CsI:Tl particles provide high light output with good energy resolution for sup 5 sup 5 Fe, sup 1 sup 0 sup 9 Cd, sup 2 sup 4 sup 1 Am sources, and are capable of detecting both X-rays and alpha-, beta-particles.

  16. Scintillator detector array

    International Nuclear Information System (INIS)

    Cusano, D.A.; Dibianca, F.A.

    1981-01-01

    This patent application relates to a scintillator detector array for use in computerized tomography and comprises a housing including a plurality of chambers, the said housing having a front wall transmissive to x-rays and side walls opaque to x-rays, such as of tungsten and tantalum, a liquid scintillation medium including a soluble fluor, the solvent for the fluor being disposed in the chambers. The solvent comprises either an intrinsically high Z solvent or a solvent which has dissolved therein a high Z compound e.g. iodo or bromonaphthalene; or toluene, xylene or trimethylbenzene with a lead or tin alkyl dissolved therein. Also disposed about the chambers are a plurality of photoelectric devices. (author)

  17. DETECTORS: scintillating fibres

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    In the continual search for improved detection techniques, new materials are continually proving profitable. A good example is scintillating plastic fibres - tiny transparent threads sometimes finer than a human hair which transmit light. The narrowness and flexibility of these fibres was a major breakthrough for endoscopy - non-invasive techniques for viewing the otherwise inaccessible in surgery or machine inspection. In a more sophisticated form, these fibres find ready application in communications technology, where the goal is to transmit information rather than electrical power, replacing conventional and unwieldy current-carrying wire conductors. In particle physics, fibres have long been used to take the tiny scintillations produced when high energy particles hit fluorescent materials and 'conduct' them to photosensitive detectors some distance away

  18. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  19. Modular scintillation camera

    International Nuclear Information System (INIS)

    Barrett, H. H.

    1985-01-01

    Improved optical coupling modules to be used in coded-aperture-type radiographic imaging systems. In a first system, a rotating slit coded-aperture is employed between the radioactive object and the module. The module consists of one pair of side-by-side photomultipliers receiving light rays from a scintillation crystal exposed to the object via the coded-aperture. The light rays are guided to the photomultipliers by a mask having a central transverse transparent window, or by a cylindrical lens, the mask or lens being mounted in a light-conveying quartz block assembly providing internal reflections at opposite faces of the assembly. This generates output signals from the photomultipliers which can be utilized to compute one-dimensional coordinate values for restoring the image of the radioactive object on a display screen. In another form of optical coupling module, usable with other types of coded-apertures, four square photomultipliers form a substantially square block and receive light rays from scintillations from a scintillation crystal exposed to the radioactive object via the coded-aperture. The light rays are guided to the photomultipliers by a square mask or a centrally transparent square lens configuration mounted in a light-conveying assembly formed by internally reflecting quartz blocks, the optical rays being directed to the respective photomultipliers so as to generate resultant output signals which can be utilized to compute image coordinate values for two-dimensional representation of the radioactive object being examined

  20. Standardization of Tc-99 by three liquid scintillation counting methods

    International Nuclear Information System (INIS)

    Wyngaardt, W.M. van; Staden, M.J. van; Lubbe, J.; Simpson, B.R.S.

    2014-01-01

    The NMISA participated in the international key comparison of the pure beta-emitter Technetium-99, CCRI(II)-K2.Tc-99. The comparison solution was standardized using three methods, namely the TDCR efficiency calculation method, the CIEMAT/NIST efficiency tracing method and the 4π(LS)β–γ coincidence tracing method with Co-60 as tracer. Excellent agreement between results obtained with the three methods confirmed the applicability of the beta spectral shape given by the latest (2011) DDEP evaluation of Tc-99 decay data, rather than the earlier (2004) evaluation. - Highlights: • Activity concentration of Tc-99 solution measured using three LSC methods. • Methods used are TDCR, CNET and 4π(LS)β–γ coincidence tracing. • Beta spectral shape confirmed by agreement between three methods

  1. General data analysis code for TDCR liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, D. [Laboratorio de Metrologia de Radioisotopos, Comision Nacional de Energia Atomica, Buenos Aires (Argentina)], E-mail: drodrigu@cae.cnea.gov.ar; Arenillas, P.; Capoulat, M.E.; Balpardo, C. [Laboratorio de Metrologia de Radioisotopos, Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    2008-06-15

    A non-radionuclide-specific computer code to analyze data, calculate detection efficiency and activity in a TDCR system is presented. The program was developed prioritizing flexibility in measuring conditions, parameters and calculation models. It is also intended to be well structured in order to easily replace subroutines which could eventually be improved by the user. It is written in standard FORTRAN language but a graphical interface is also available. Several tests were performed to check the ability of the code to deal with different decay schemes such as H-3, C-14, Fe-55, Mn-54 and Co-60.

  2. General data analysis code for TDCR liquid scintillation counting

    International Nuclear Information System (INIS)

    Rodrigues, D.; Arenillas, P.; Capoulat, M.E.; Balpardo, C.

    2008-01-01

    A non-radionuclide-specific computer code to analyze data, calculate detection efficiency and activity in a TDCR system is presented. The program was developed prioritizing flexibility in measuring conditions, parameters and calculation models. It is also intended to be well structured in order to easily replace subroutines which could eventually be improved by the user. It is written in standard FORTRAN language but a graphical interface is also available. Several tests were performed to check the ability of the code to deal with different decay schemes such as H-3, C-14, Fe-55, Mn-54 and Co-60

  3. Role of excitons in the energy resolution of scintillators used for medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Jai [School of Engineering and IT, B-purple-12, Faculty of EHS, Charles Darwin University, Darwin NT 0909 (Australia)

    2010-11-01

    Theoretical investigations suggest that the nonproportionality in a scintillator is caused by the high excitation density created within the track of an X-ray or {gamma} ray photon entering in a scintillating crystal. In this paper an analytical expression for the scintillator yield is derived. For the case of BaF{sub 2} scintillator the role of excitons created within the {gamma}-ray track in the scintillator yield is studied. By comparing the results of two theories an analytical expression is also derived for an energy parameter which could otherwise only be determined by fitting the theoretical yield to the experimental data.

  4. Role of excitons in the energy resolution of scintillators used for medical imaging

    International Nuclear Information System (INIS)

    Singh, Jai

    2010-01-01

    Theoretical investigations suggest that the nonproportionality in a scintillator is caused by the high excitation density created within the track of an X-ray or γ ray photon entering in a scintillating crystal. In this paper an analytical expression for the scintillator yield is derived. For the case of BaF 2 scintillator the role of excitons created within the γ-ray track in the scintillator yield is studied. By comparing the results of two theories an analytical expression is also derived for an energy parameter which could otherwise only be determined by fitting the theoretical yield to the experimental data.

  5. Properties of the ukrainian polystyrene-based plastic scintillator UPS 923A

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Chirikov-Zorin, I.; Lyablin, M.; Chokheli, D.; Bellettini, G.; Mensione, A.; Tokar, S; Giokaris, N.; Manousakis-Katsikakis, A.

    2005-01-01

    The polystyrene-based scintillator UPS 923A was chosen for upgrading of the muon system for the CDF detector at the Fermilab Tevatron. Properties of this scintillator such as light output, light attenuation, long-term stability and also timing characteristics of the scintillator and wavelength shifting fibers were investigated. The method for the Bulk Attenuation Length measurements of the scintillator to its own light emitted was proposed. Comparative measurements of the characteristics of the UPS 923A and the polyvinyltoluene-based scintillator NE 114 were performed. It was found that natural aging of the NE 114 was two times faster than that of the UPS 923A

  6. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  7. Studying the properties of the new class of organic scintillators-salicylic acid derivatives

    International Nuclear Information System (INIS)

    Mandzhukov, I.G.; Mandzhukova, B.V.; Bonchev, Ts.V.; Lazarova, G.I.

    1981-01-01

    Li, Na, K, Mg, Ca, Sr, Ba, La, Cd, Al, Sn, NH 4 salicylates are synthesized. Their relative scintillation efficiency during irradiation with α-particles of 5.156 MeV energy (sup(239)Pu) is determined. Scintillation efficiency of salicylates has been evaluated by comparing amplitude of scintillation pulse from salicylate with pulse amplitude from anthracene and other classical scintillators. Amplitude analysis has been conducted by standard methods. The analysis of the results obtained shows that sodium salicylate has the highest relative scintillation efficiency comparable with naphthalene efficiency. Salicylates of alkali Li and K metals as well as Ca and Cd salicylates have high relative scintillation efficiency. It is concluded that the investigated salicylates can be used for detection of (n, α), (n, p) and other reactions accompanying neutron capture not only during their reactions but by measuring activity induced in the scintillator [ru

  8. A novel methodology for online measurement of thoron using Lucas scintillation cell

    International Nuclear Information System (INIS)

    Eappen, K.P.; Sapra, B.K.; Mayya, Y.S.

    2007-01-01

    The use of Lucas scintillation cell (LSC) technique for thoron estimation requires a modified methodology as opposed to radon estimation. While in the latter, the α counting is performed after a delay period varying between few hours to few days, in the case of thoron estimation the α counting has to be carried out immediately after sampling owing to the short half-life of thoron (55 s). This can be achieved best by having an on-line LSC sampling and counting system. However, half-life of the thoron decay product 212 Pb being 10.6 h, the background accumulates in LSC during online measurements and hence subsequent use of LSC is erroneous unless normal background level is achieved in the cell. This problem can be circumvented by correcting for the average background counts accumulated during the counting period which may be theoretically estimated. In this study, a methodology has been developed to estimate the true counts due to thoron. A linear regression between the counts obtained experimentally and the fractional decay in regular intervals of time is used to obtain the actual thoron concentration. The novelty of this approach is that the background of the cell is automatically estimated as the intercept of the regression graph. The results obtained by this technique compare well with the two filter method and the thoron concentration produced from a standard thoron source. However, the LSC as such cannot be used for environmental samples because the minimum detection level is comparable with that of thoron concentrations prevailing in normal atmosphere

  9. Development of new Polysiloxane Based Liquid Scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, M.; Quaranta, A. [Department of Industrial Engineering, University of Trento,Via Sommarive, 9, 38123 Trento (Italy); INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Gramegna, F.; Marchi, T.; Cinausero, M. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Carturan, S.; Collazuol, G.; Checchia, C. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Department of Physics and Astronomy, University of Padova, Via Marzolo, 8, 35131 Padova (Italy); Degerlier, M. [Department of Physics, Nevsehir Haci Bektas Veli University, Science and Art Faculty, 50300 Nevsehir (Turkey)

    2015-07-01

    In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non

  10. Renal Function Studies with a Scintillation Camera

    Energy Technology Data Exchange (ETDEWEB)

    Farmelant, M. H.; Genna, S.; Burrows, B. A. [University Hospital and Boston Veterans Administration Hospital, Boston, MA (United States)

    1969-05-15

    Renal function studies with {sup 131}I-Hippuran have usually been performed with two probes, with flat field collimators, of which the sensitivity is dependent on kidney position. Although a variety of methods have been used to interpret the results, it is almost universally agreed that the relative magnitudes of the curves obtained during the accumulation phase are determined by both the relative blood flow and relative geometrical efficiency of counting. The relative influence of these two factors is not easily ascertained. Because of this limitation in directly assessing relative renal blood flow indirect methods have evolved. From physiological studies in dogs it appears that differences between the kidneys in blood flow produce differences in renal passage time and subsequently differences in the descending portions of the curves. Evaluation of differences in the descending curves in patients has proved highly sensitive in detecting renal vascular disease causing hypertension. However, obstructive disorders of urine outflow also produce alterations in the declining portion of the curve. A scintillation camera provides a detector considerably larger than the kidney and uses parallel hole collimation. This arrangement results in count-rates that are largely independent of kidney position, as shown by phantom studies. Furthermore, sequential scintigraphs can be obtained. Using the Pho-Gamma III (Nuclear Chicago) with 'split' crystal for clinical studies, we have demonstrated that the relative uptake of {sup 131}I-Hippuran by the two kidneys during the accumulation phase differs by less than 15% in normal people. These differences may be related to differences in kidney size or blood flow. Differences greater than this suggest significant differences between the kidneys in renal blood flow if the scintigrams show kidneys of comparable size. The sequential scintigrams have proven to be accurate in differentiating retention of radioisotope due to vascular disease

  11. Scintillation properties of selected oxide monocrystals activated with Ce and Pr

    Science.gov (United States)

    Wojtowicz, Andrzej J.; Drozdowski, Winicjusz; Wisniewski, Dariusz; Lefaucheur, Jean-Luc; Galazka, Zbigniew; Gou, Zhenhui; Lukasiewicz, Tadeusz; Kisielewski, Jaroslaw

    2006-01-01

    In the last 10-15 years there has been a significant effort toward development of new, more efficient and faster materials for detection of ionizing radiation. A growing demand for better scintillator crystals for detection of 511 keV gamma particles has been due mostly to recent advances in modern imaging systems employing positron emitting radionuclides for medical diagnostics in neurology, oncology and cardiology. While older imaging systems were almost exclusively based on BGO and NaI:Tl crystals the new systems, e.g., ECAT Accel, developed by Siemens/CTI, are based on recently discovered and developed LSO (Lu 2SiO 5:Ce, Ce-activated lutetium oxyorthosilicate) crystals. Interestingly, despite very good properties of LSO, there still is a strong drive toward development of new scintillator crystals that would show even better performance and characteristics. In this presentation we shall review spectroscopic and scintillator characterization of new complex oxide crystals, namely LSO, LYSO, YAG, LuAP (LuAlO 3, lutetium aluminate perovskite) and LuYAP activated with Ce and Pr. The LSO:Ce crystals have been grown by CTI Inc (USA), LYSO:Ce, LuAP:Ce and LuYAP:Ce crystals have been grown by Photonic Materials Ltd., Scotland (PML is the only company providing large LuAP:Ce crystals on a commercial scale), while YAG:Pr and LuAP:Pr crystals have been grown by Institute of Electronic Materials Technology (Poland). All these crystals have been characterized at Institute of Physics, N. Copernicus University (Poland). We will review and compare results of measurements of radioluminescence, VUV spectroscopy, scintillation light yields, scintillation time profiles and low temperature thermoluminescence performed on these crystals. We will demonstrate that all experiments clearly indicate that there is a significant room for improvement of LuAP, LuYAP and YAG. While both Ce-activated LSO and LYSO perform very well, we also note that LuYAP:Ce, LuAP:Ce and YAG:Pr offer some

  12. {sup 222}Rn determination in water and brine samples using liquid scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Thiago C.; Oliveira, Arno H., E-mail: oliveiratco2010@gmail.com [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Monteiro, Roberto P.G.; Moreira, Rubens M., E-mail: rpgm@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Liquid scintillation spectrometry (LSC) is the most common technique used for {sup 222}Rn determination in environmental aqueous sample. In this study, the performance of water-miscible (Ultima Gold AB) and immiscible (Optiscint) liquid scintillation cocktails has been compared for different matrices. {sup 241}Am, {sup 90}Sr and {sup 226}Ra standard solutions were used for LSC calibration. {sup 214}Po region was defined as better for both cocktails. Counting efficiency of 76 % and optimum PSA level of 95 for Ultima Gold AB cocktail, and counting efficiency of 82 % and optimum PSA level of 85 for Optiscint cocktail were obtained. Both cocktails showed similar results when applied for {sup 222}Rn activity determination in water and brine samples. However the Optiscint is recommended due to its quenching resistance. Limit of detection of 0.08 and 0.06 Bq l{sup -1} were obtained for water samples using a sample:cocktail ratio of 10:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. Limit of detection of 0.08 and 0.04 Bq l{sup -1} were obtained for brine samples using a sample:cocktail ratio of 8:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. (author)

  13. 222Rn determination in water and brine samples using liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Oliveira, Thiago C.; Oliveira, Arno H.

    2017-01-01

    Liquid scintillation spectrometry (LSC) is the most common technique used for 222 Rn determination in environmental aqueous sample. In this study, the performance of water-miscible (Ultima Gold AB) and immiscible (Optiscint) liquid scintillation cocktails has been compared for different matrices. 241 Am, 90 Sr and 226 Ra standard solutions were used for LSC calibration. 214 Po region was defined as better for both cocktails. Counting efficiency of 76 % and optimum PSA level of 95 for Ultima Gold AB cocktail, and counting efficiency of 82 % and optimum PSA level of 85 for Optiscint cocktail were obtained. Both cocktails showed similar results when applied for 222 Rn activity determination in water and brine samples. However the Optiscint is recommended due to its quenching resistance. Limit of detection of 0.08 and 0.06 Bq l -1 were obtained for water samples using a sample:cocktail ratio of 10:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. Limit of detection of 0.08 and 0.04 Bq l -1 were obtained for brine samples using a sample:cocktail ratio of 8:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. (author)

  14. Neutron crosstalk between liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Verbeke, J.M., E-mail: verbeke2@llnl.gov; Prasad, M.K., E-mail: prasad1@llnl.gov; Snyderman, N.J., E-mail: snyderman1@llnl.gov

    2015-09-11

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction.

  15. Neutron crosstalk between liquid scintillators

    International Nuclear Information System (INIS)

    Verbeke, J.M.; Prasad, M.K.; Snyderman, N.J.

    2015-01-01

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction

  16. Quantitative Compton suppression spectrometry at elevated counting rates

    International Nuclear Information System (INIS)

    Westphal, G.P.; Joestl, K.; Schroeder, P.; Lauster, R.; Hausch, E.

    1999-01-01

    For quantitative Compton suppression spectrometry the decrease of coincidence efficiency with counting rate should be made negligible to avoid a virtual increase of relative peak areas of coincident isomeric transitions with counting rate. To that aim, a separate amplifier and discriminator has been used for each of the eight segments of the active shield of a new well-type Compton suppression spectrometer, together with an optimized, minimum dead-time design of the anticoincidence logic circuitry. Chance coincidence losses in the Compton suppression spectrometer are corrected instrumentally by comparing the chance coincidence rate to the counting rate of the germanium detector in a pulse-counting Busy circuit (G.P. Westphal, J. Rad. Chem. 179 (1994) 55) which is combined with the spectrometer's LFC counting loss correction system. The normally not observable chance coincidence rate is reconstructed from the rates of germanium detector and scintillation detector in an auxiliary coincidence unit, after the destruction of true coincidence by delaying one of the coincidence partners. Quantitative system response has been tested in two-source measurements with a fixed reference source of 60 Co of 14 kc/s, and various samples of 137 Cs, up to aggregate counting rates of 180 kc/s for the well-type detector, and more than 1400 kc/s for the BGO shield. In these measurements, the net peak areas of the 1173.3 keV line of 60 Co remained constant at typical values of 37 000 with and 95 000 without Compton suppression, with maximum deviations from the average of less than 1.5%

  17. Ionization and scintillation of nuclear recoils in gaseous xenon

    Energy Technology Data Exchange (ETDEWEB)

    Renner, J., E-mail: jrenner@lbl.gov [Lawrence Berkeley National Laboratory (LBNL), 1 Cyclotron Road, Berkeley, CA 94720 (United States); Department of Physics, University of California, Berkeley, CA 94720 (United States); Gehman, V.M.; Goldschmidt, A.; Matis, H.S.; Miller, T.; Nakajima, Y.; Nygren, D.; Oliveira, C.A.B.; Shuman, D. [Lawrence Berkeley National Laboratory (LBNL), 1 Cyclotron Road, Berkeley, CA 94720 (United States); Álvarez, V. [Instituto de Física Corpuscular (IFIC), CSIC & Universitat de València, Calle Catedrático José Beltrán, 2, 46980 Paterna, Valencia (Spain); Borges, F.I.G. [Departamento de Fisica, Universidade de Coimbra, Rua Larga, 3004-516 Coimbra (Portugal); Cárcel, S. [Instituto de Física Corpuscular (IFIC), CSIC & Universitat de València, Calle Catedrático José Beltrán, 2, 46980 Paterna, Valencia (Spain); Castel, J.; Cebrián, S. [Laboratorio de Física Nuclear y Astropartículas, Universidad de Zaragoza, Calle Pedro Cerbuna 12, 50009 Zaragoza (Spain); Cervera, A. [Instituto de Física Corpuscular (IFIC), CSIC & Universitat de València, Calle Catedrático José Beltrán, 2, 46980 Paterna, Valencia (Spain); Conde, C.A.N. [Departamento de Fisica, Universidade de Coimbra, Rua Larga, 3004-516 Coimbra (Portugal); and others

    2015-09-01

    Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope α-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments.

  18. Liquid scintillation spectrometer survey 155Eu liquid activity

    International Nuclear Information System (INIS)

    Zhang Zuhua

    2002-01-01

    In the countrywide contrasting survey of 155 Eu activity, 155 Eu liquid activity was determined for the first time through using liquid scintillation spectrometer survey 155 Eu β ray. In survey total uncertainty, determining activity accord with determining activity average value of all a wide variety of survey instrument entering into contrasting survey. But using liquid scintillation spectrometer survey, it is simple and save time, is beyond compare for other survey method. It indicate liquid scintillation spectrometer survey β-γ nuclide activity is effective as well

  19. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.

    2014-11-01

    In order to evaluate the age from the equivalent dose and to obtain an optimized and efficient procedure for thermoluminescence (TL) dating, it is necessary to obtain the values of both the internal and the external dose rates from dated samples and from their environment. The measurements described and compared in this paper refer to bricks from historic buildings and a fine-grain dating method. The external doses are therefore negligible, if the samples are taken from a sufficient depth in the wall. However, both the alpha dose rate and the beta and gamma dose rates must be taken into account in the internal dose. The internal dose rate to fine-grain samples is caused by the concentrations of natural radionuclides 238U, 235U, 232Th and members of their decay chains, and by 40K concentrations. Various methods can be used for determining trace concentrations of these natural radionuclides and their contributions to the dose rate. The dose rate fraction from 238U and 232Th can be calculated, e.g., from the alpha count rate, or from the concentrations of 238U and 232Th, measured by neutron activation analysis (NAA). The dose rate fraction from 40K can be calculated from the concentration of potassium measured, e.g., by X-ray fluorescence analysis (XRF) or by NAA. Alpha counting and XRF are relatively simple and are accessible for an ordinary laboratory. NAA can be considered as a more accurate method, but it is more demanding regarding time and costs, since it needs a nuclear reactor as a neutron source. A comparison of these methods allows us to decide whether the time- and cost-saving simpler techniques introduce uncertainty that is still acceptable.

  20. Positron imaging system with improved count rate and tomographic capability

    International Nuclear Information System (INIS)

    Muehllehner, G.; Buchin, M.P.

    1980-01-01

    Improvements to a positron camera imaging system are described. A pair of Angear-type scintillation cameras serve as the detectors, each camera being positioned on opposite sides of the organ of interest. Pulse shaping circuits reduce the pulse duration below 900 nanoseconds and the integration time below 500 noneseconds, improving the count rate capability and the counting statistics of the system and thus the image quality and processing speed. The invention also provides means for rotating the opposed camera heads about an axis which passes through the organ of interest. The cameras do not use collimators, and are capable of accepting radiation travelling in planes not perpendicular to the scintillation crystals. (LL)

  1. Establishment of methodology for determination of {sup 93}Zr in radioactive wastes by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS); Estabelecimento de metodologia para determinacao de {sup 93}Zr em rejeitos radioativos por Espectrometria de Cintilacao Liquida (LSC) e Espectrometria de Massa com Plasma Indutivamente Acoplado (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Thiago Cesar de

    2014-06-01

    The zirconium-93 is a long-lived pure β-particle-emitting radionuclide produced from {sup 235}U fission and from neutron activation of the stable isotope {sup 92}Zr and thus occurring as one of the radionuclides found in nuclear reactors. Due to its long half life, {sup 93}Zr is one of the radionuclides of interest for the performance of assessment studies of waste storage or disposal. Measurement of {sup 93}Zr is difficult owing to its trace level concentration and its low activity in nuclear wastes and further because its certified standards are not frequently available. The aim of this work was to develop a selective radiochemical separation methodology for the determination of {sup 93}Zr in nuclear waste and analyze it by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). To set up the radiochemical separation procedure for zirconium, a tracer solution of {sup 95}Zr and its 724 keV γ-ray measurements by γ- spectrometry were used in order to follow the behavior of zirconium during the radiochemical separation. For the LSC technique a {sup 55}Fe solution, which is one of the major interfering measures zirconium, was used to verify the decontamination factor during the separation process. The efficiency detection for {sup 63}Ni was used to determination of {sup 93}Zr activity in the matrices analyzed. The limit of detection of the 0.05 Bq 1{sup −1} was obtained for {sup 63}Ni standard solutions by using a sample:cocktail ratio of 3:17 mL for Optiphase Hisafe 3 cocktail. For the ICP-MS technique a zirconium stable solution was used to verify the zirconium behavior and recovery during radiochemical separation and a solution of Ba, Co, Eu, Fe, Mn, Nb, Sr and Y was used to verify the decontamination factor during the separation process. A standard solution {sup 93}Nb as isotope for determining the {sup 93}Zr by ICP-MS was used for calibration and analysis. The detection limit of 0.039 ppb was obtained for the standard

  2. Liquid Scintillation High Resolution Spectral Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    2010-08-06

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  3. Liquid Scintillation High Resolution Spectral Analysis

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    2010-01-01

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  4. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM.

    Science.gov (United States)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-04-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  6. New advanced in alpha spectrometry by liquid scintillation methods

    International Nuclear Information System (INIS)

    McDowell, W.J.; Case, G.N.

    1979-01-01

    Although the ability to count alpha particles by liquid scintillation methods has been long recognized, limited use has been made of the method because of problems of high background and alpha energy identification. In recent years some new developments in methods of introducing the alpha-emitting nuclide to the scintillator, in detector construction, and in electronics for processing the energy analog and time analog signals from the detector have allowed significant alleviation of the problems of alpha spectrometry by liquid scintillation. Energy resolutions of 200 to 300 keV full peak width at half maximum and background counts of 99% of all beta plus gamma interference is now possible. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are available for a variety of analyses

  7. Study of the correlation of scintillation decay and emission wavelength

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Fujimoto, Yutaka; Yamaji, Akihiro; Kawaguchi, Noriaki; Kamada, Kei; Totsuka, Daisuke; Fukuda, Kentaro; Yamanoi, Kohei; Nishi, Ryosuke; Kurosawa, Shunsuke; Shimizu, Toshihiko; Sarukura, Nobuhiko

    2013-01-01

    In photoluminescence which directly excites the emission center of phosphor material is known to have a correlation between the emission wavelength and the decay time based on quantum mechanics. In scintillation phenomenon, host lattice of the material is first excited by ionizing radiation and then the excitation energy is transferred to emission centers. For the first time, we investigated the correlation between the scintillation decay and the emission wavelength by using pulse X-ray equipped streak camera system which could observe time and wavelength resolved scintillation phenomenon. Investigated materials were Ce 3+ , Pr 3+ and Nd 3+ doped oxides and fluorides which all showed 5d-4f transition based emission. As a result, we obtained the relation that τ (scintillation decay time) was proportional to the λ 2.15 (emission wavelength). -- Highlights: ► The correlation between emission wavelength and scintillation decay time is investigated. ► Photoluminescence decay times are also evaluated and compared with scintillation decay times. ► It is proved the relaxation process in emission center is dominant even in scintillation decay

  8. Scintillating-fibre calorimetry

    International Nuclear Information System (INIS)

    Livan, M.; Vercesi, V.; Wigmans, R.

    1995-01-01

    In the past decade, calorimetry based on scintillating plastic fibres as active elements was developed from a conceptual idea to a mature detector technology, which is nowadays widely applied in particle physics experiments. This development and the performance characteristics of representative calorimeters, both for the detection of electromagnetic and hadronic showers, are reviewed. We also discuss new information on shower development processes in dense matter and its application to calorimetric principles that has emerged from some very thorough studies that were performed in the framework of this development. (orig.)

  9. A 15 channel 2- and 3-fold coincidence counting system for radioactivity standardization

    International Nuclear Information System (INIS)

    Simpson, B.R.S.; Meyer, B.R.; Raave, D.A.

    1986-01-01

    The 4π β-γ liquid scintillation coincidence counting system which is used at the National Accelerator Centre for standardizing radioisotopes, has been extended to allow for up to fifteen data points to be measured simultaneously by introducing a 15-fold coincidence unit and a 32-channel scaler into the system. A new control / data acquisition computer program has been written and its operation explained in detail. The advantages of the new system are discussed, and the activity of a 139 Ce source as measured by the new system and the old 3-fold system is compared

  10. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase

    International Nuclear Information System (INIS)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-01-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ( 3 H, 1 4C, 3 5S, 3 2P and 9 0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  11. Hybrid scintillators for neutron discrimination

    Science.gov (United States)

    Feng, Patrick L; Cordaro, Joseph G; Anstey, Mitchell R; Morales, Alfredo M

    2015-05-12

    A composition capable of producing a unique scintillation response to neutrons and gamma rays, comprising (i) at least one surfactant; (ii) a polar hydrogen-bonding solvent; and (iii) at least one luminophore. A method including combining at least one surfactant, a polar hydrogen-bonding solvent and at least one luminophore in a scintillation cell under vacuum or an inert atmosphere.

  12. A user's guide to scintillation

    International Nuclear Information System (INIS)

    Hewish, A.

    1989-01-01

    During the past four decades scintillation methods have been used for remote-sensing distant plasmas and for providing high angular resolution in radioastronomy. This brief review illustrates some of the techniques employed and explains the underlying theory in simple physical terms; it is not intended to be a complete survey of all applications of scintillation. (author)

  13. Laser Beam Scintillation with Applications

    CERN Document Server

    Andrews, Larry C; Young, Cynthia

    2001-01-01

    Renewed interest in laser communication systems has sparked development of useful new analytic models. This book discusses optical scintillation and its impact on system performance in free-space optical communication and laser radar applications, with a detailed look at propagation phenomena and the role of scintillation on system behavior. Intended for practicing engineers, scientists, and students.

  14. Scintillation light transport and detection

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Lillie, R.A.

    1986-08-01

    The MORSE neutron gamma-ray transport code has been modified to allow for the transport of scintillation light. This modified code is used to analyze the light collection characteristics of a large liquid scintillator module (18 x 18 x 350 cm 3 )

  15. Extruding plastic scintillator at Fermilab

    International Nuclear Information System (INIS)

    Pla-Dalmau, Anna; Bross, Alain D.; Rykalin, Viktor V.

    2003-01-01

    An understanding of the costs involved in the production of plastic scintillators and the development of a less expensive material have become necessary with the prospects of building very large plastic scintillation detectors. Several factors contribute to the high cost of plastic scintillating sheets, but the principal reason is the labor-intensive nature of the manufacturing process. In order to significantly lower the costs, the current casting procedures had to be abandoned. Since polystyrene is widely used in the consumer industry, the logical path was to investigate the extrusion of commercial-grade polystyrene pellets with dopants to yield high quality plastic scintillator. This concept was tested and high quality extruded plastic scintillator was produced. The D0 and MINOS experiments are already using extruded scintillator strips in their detectors. An extrusion line has recently been installed at Fermilab in collaboration with NICADD (Northern Illinois Center for Accelerator and Detector Development). This new facility will serve to further develop and improve extruded plastic scintillator. This paper will discuss the characteristics of extruded plastic scintillator and its raw materials, the different manufacturing techniques and the current R andD program at Fermilab

  16. CELL RESPIRATION STUDIES : II. A COMPARATIVE STUDY OF THE OXYGEN CONSUMPTION OF BLOOD FROM NORMAL INDIVIDUALS AND PATIENTS WITH INCREASED LEUCOCYTE COUNTS (SEPSIS; CHRONIC MYELOGENOUS LEUCEMIA).

    Science.gov (United States)

    Daland, G A; Isaacs, R

    1927-06-30

    1. The oxygen consumption of blood of normal individuals, when the hemoglobin is saturated with oxygen, is practically zero within the limits of experimental error of the microspirometer used. 2. The oxygen consumed in a microspirometer by the blood of patients with chronic myelogenous leucemia with a high white blood cell count, and of one with leucocytosis from sepsis, was proportional to the number of adult polymorphonuclear neutrophils in the blood. 3. No correlation could be made between the rate of oxygen absorption and the total number of white blood cells in the blood, or the total number of immature cells, or the number of red blood cells, or the amount of oxyhemoglobin. 4. The blood of patients with chronic myelogenous leucemia continued to use oxygen in the microspirometer longer than that of normal individuals, and the hemoglobin, in the leucemic bloods, became desaturated even though exposed to air. 5. In blood in which the bulk. of the cells were immature and the mature cells few, the oxygen consumption was lower than in blood in which the mature cells predominated. The rate of oxygen consumption of the immature cells was relatively low as compared to the mature. 6. The slower rate of oxygen absorption by the immature leucocytes in chronic myelogenous leucemia as compared to the mature cells, places them, in accord with Warburg's reports, in the class of the malignant tissues in this respect rather than in the group of young or embryonic cells.

  17. Method for determining efficiency in a liquid scintillation system

    International Nuclear Information System (INIS)

    Laney, B.H.

    1975-01-01

    In a liquid scintillation system utilizing plural photomultiplyier means, a method for determining efficiency of coincident pulse detection. Various incremental counting efficiency levels are associated with asymptotic functions in a two dimension matrix in which the abscissa and ordinate correspond to the pulse heights of each of a pair of coincident pulses from different photomultiplier means. An efficiency determining point is located in the matrix based on the sum of the pulse heights of each of the coincident pulses as well as on the amplitude of the smallest pulse of the coincident pulses. The single counting efficiency determining point is recorded as the level of efficiency at which the photomultiplier means detect scintillations that generate coincident pulses having pulse heights equal to those recorded. (Patent Office Record)

  18. Well scintillation counter with automatic sample changing and data processing: an inexpensive instrument incorporating consumer products

    International Nuclear Information System (INIS)

    Dudley, R.A.; Figdor, H.C.; Keroe, E.A.; Morris, A.C. Jr.; Mutz, O.J.

    1977-01-01

    An automatic well scintillation-counting system suitable for in vitro assays with 125 I has been designed with the express purpose of allowing effective operation and maintenance in laboratories in developing countries. The system incorporates comparatively simple components, notably two consumer products: A Kodak Carousel slide projector as sample changer and a Hewlett-Packard HP-97 programmable printing calculator as system controller and data processor. The instrument can accomodate 80 counting vials of demensions 12 mm diameter x 75 mm, or 40 vials of 16 mm diameter x 100 mm. The calculator provides on-line control and data reduction with the mediation of an interface somewhat resembling that required between a scaler and a printer. Its program capacity is adequate for fairly complicated on-line operations, including, interpolation from a standard curve in logit-log space, calculation of error in hormone concentration, and termination of counting when the counting error is rediced to a prescribed fraction of the composite of other random assay errors (as stored in the calculator's memory). This system is inexpensive, robust, and capable of being operated manually if automatic accessories fail. It could be improved in several ways, particularly by providing for operation from batteries and, no doubt in the immediate future, substitution of the next generation of cheaper and more powerful calculators. The instrument may be cost-effective in any small to medium-sized laboratory. (orig.) [de

  19. Primary 4πβ-γ coincidence system for standardization of radionuclides by means of plastic scintillators

    International Nuclear Information System (INIS)

    Baccarelli, Aida Maria

    2003-01-01

    The present work describes a 4π(α,β)-γ coincidence system for absolute measurement of radionuclide activity using a plastic scintillator in 4π geometry for charged particles detection and a Nal (Tl) crystal for gamma-ray detection. Several shapes and dimensions of the plastic scintillator have been tried in order to obtain the best system configuration. Radionuclides which decay by alpha emission, β - , β + and electron capture have been standardized. The results showed excellent agreement with other conventional primary system which makes use of a 4π proportional counter for X-ray and charged particle detection. The system developed in the present work have some advantages when compared with the conventional systems, namely; it does not need metal coating on the films used as radioactive source holders. When compared to liquid scintillators, is showed the advantage of not needing to be kept in dark for more than 24 h to allow phosphorescence decay of ambient light. Therefore it can be set to count immediately after the sources are placed inside of it. (author)

  20. Scintillation properties of GSO

    International Nuclear Information System (INIS)

    Melcher, C.L.; Schweitzer, J.S.; Utsu, T.; Akiyama, S.

    1990-01-01

    The timing properties of Gd 2 SiO 5 :Ce (GSO) single crystal scintillators have previously been evaluated for positron emission tomography applications. The measured time resolution, however, was worse than expected from calculations based on photoelectron yield and a 60 nanosecond exponential decay constant, leading us to further investigate GSO's basic properties. With a time-correlated-single-photon technique, the authors have found two decay components, one of 56 ns and one of 600 ns, the latter containing 10--15% of the total scintillation output. This may explain the difference between the experimental and theoretical time resolutions and confirms a previous hypothesis of a long decay component. In addition, the authors have found that each component's decay constant strongly depends on the cerium concentration. The primary component varies from ∼ 20 ns to ∼ 190 ns and the secondary component varies from ∼ 70 ns to ∼ 1200 ns as the cerium concentration is varied from 5.0 mol% to 0.1 mol%

  1. The two plastic scintillator measuring system HBG-2

    International Nuclear Information System (INIS)

    Tran Manh Toan; Nguyen Trieu Tu

    1992-01-01

    The beta-gamma measuring system HBG-2 is described. It consist of: 1. Two 40mm Φ x 3mm plastic scintillators, a beta-filter, a shielded cell, and a coincidence circuit; 2. Four counting channels in which one is reversible. A device is capable of measuring low-level activity. Some special measuring methods provided by the equipment are presented, too. (author). 6 refs, 3

  2. Standardization of 137 Cs+137m Ba by Liquid Scintillation

    International Nuclear Information System (INIS)

    Rodriguez, L.; Arcos, J.M., los; Grau Carles, A.

    1995-09-01

    A procedure for the preparation of a stable, homogeneous solution of ''137 Cs+''137m Ba, for use in liquid scintillation measurements, is described. Its count rate stability and spectral time evolution has been followed for several weeks. The solution has been standardised by the CIEMAT/NIST method in both Ultima-Gold and Insta-Gel, to a combined uncertainty lower than 0,51% (k=1)

  3. Construction and implementation of a liquid scintillation TDCR system

    International Nuclear Information System (INIS)

    Wu Yongle; Liang Juncheng; Liu Jiacheng; Yang Yuandi; Yuan Daqing

    2012-01-01

    The triple-to-double coincidence ratio (TDCR) method is an absolute measurement method of radioactivity, and is a popular technique for the standardization of pure beta radionuclides. A triple-to-double coincidence ratio (TDCR) liquid scintillation counting system has been constructed in China. A description of the system and measured activities for sources such as 3 H and 99 Te are presented. (authors)

  4. Determination of phosphorus-32 in wet-digested plant leaves by Cerenkov counting

    International Nuclear Information System (INIS)

    Wahid, P.A.; Kamalam, N.V.; Sankar, S.J.

    1985-01-01

    A method of determination of 32 P activity in leaf samples by Cerenkov counting technique is described. The method involves wet digestion of oven-dried leaves with 1:1 nitric-perchloric acid mixture followed by transferring the digest into a scintillation counting vial with distilled water upto a final volume of 20 mL, and determining the activity in a liquid scintillation system. Reproducible count rates can be obtained if the vials are counted after 4h allowing the silica in the digest to settle. (author)

  5. Advanced Multilayer Composite Heavy-Oxide Scintillator Detectors for High Efficiency Fast Neutron Detection

    Science.gov (United States)

    Ryzhikov, Vladimir D.; Naydenov, Sergei V.; Pochet, Thierry; Onyshchenko, Gennadiy M.; Piven, Leonid A.; Smith, Craig F.

    2018-01-01

    We have developed and evaluated a new approach to fast neutron and neutron-gamma detection based on large-area multilayer composite heterogeneous detection media consisting of dispersed granules of small-crystalline scintillators contained in a transparent organic (plastic) matrix. Layers of the composite material are alternated with layers of transparent plastic scintillator material serving as light guides. The resulting detection medium - designated as ZEBRA - serves as both an active neutron converter and a detection scintillator which is designed to detect both neutrons and gamma-quanta. The composite layers of the ZEBRA detector consist of small heavy-oxide scintillators in the form of granules of crystalline BGO, GSO, ZWO, PWO and other materials. We have produced and tested the ZEBRA detector of sizes 100x100x41 mm and greater, and determined that they have very high efficiency of fast neutron detection (up to 49% or greater), comparable to that which can be achieved by large sized heavy-oxide single crystals of about Ø40x80 cm3 volume. We have also studied the sensitivity variation to fast neutron detection by using different types of multilayer ZEBRA detectors of 100 cm2 surface area and 41 mm thickness (with a detector weight of about 1 kg) and found it to be comparable to the sensitivity of a 3He-detector representing a total cross-section of about 2000 cm2 (with a weight of detector, including its plastic moderator, of about 120 kg). The measured count rate in response to a fast neutron source of 252Cf at 2 m for the ZEBRA-GSO detector of size 100x100x41 mm3 was 2.84 cps/ng, and this count rate can be doubled by increasing the detector height (and area) up to 200x100 mm2. In summary, the ZEBRA detectors represent a new type of high efficiency and low cost solid-state neutron detector that can be used for stationary neutron/gamma portals. They may represent an interesting alternative to expensive, bulky gas counters based on 3He or 10B neutron

  6. Method for determining the irradiation dose deposited in a scintillator by ionising radiation and associated device - WO 2013060745 A1

    International Nuclear Information System (INIS)

    2013-01-01

    The invention relates to a method for determining an irradiation dose deposited in a scintillator (5) by ionising radiation, said method comprising the steps of: irradiating the scintillator (5) for a pre-determined time; detecting an instant at which the scintillator (5) is excited, using a first photodetector (11); subsequently, detecting an instant at which a scintillation photon is received, using a second photodetector (14) operating in single photon counting mode; identifying each sequence formed by the detection of an excitation instant by the first photodetector (11) and the detection of a reception instant by the second photodetector (14) at a coincidence event; counting the number of coincidence events; and obtaining the irradiation dose deposited during the irradiation time as a function of the number of coincidence events counted and a pre-determined proportionality factor. (authors)

  7. Discrimination of Naturally Occurring Radioactive Material in Plastic Scintillator Material

    International Nuclear Information System (INIS)

    Ely, James H.; Kouzes, Richard T.; Geelhood, Bruce D.; Schweppe, John E.; Warner, Ray A.

    2003-01-01

    Plastic scintillator material is used in many applications for the detection of gamma-rays from radioactive material, primarily due to the sensitivity per unit cost compared to other detection materials. However, the resolution and lack of full-energy peaks in the plastic scintillator material prohibits detailed spectroscopy. Therefore, other materials such as doped sodium iodide are used for spectroscopic applications. The limited spectroscopic information can however be exploited in plastic scintillator materials to provide some discrimination. The discrimination between man-made and naturally occurring sources would be useful in reducing alarm screening for radiation detection applications which target man-made sources. The results of applying the limited energy information from plastic scintillator material for radiation portal monitors are discussed.

  8. Recent developments in plastic scintillators with pulse shape discrimination

    Science.gov (United States)

    Zaitseva, N. P.; Glenn, A. M.; Mabe, A. N.; Carman, M. L.; Hurlbut, C. R.; Inman, J. W.; Payne, S. A.

    2018-05-01

    The paper reports results of studies conducted to improve scintillation performance of plastic scintillators capable of neutron/gamma pulse-shape discrimination (PSD). Compositional modifications made with the polymer matrix improved physical stability, allowing for increased loads of the primary dye that, in combination with selected secondary dyes, provided enhanced PSD especially important for the lower energy ranges. Additional measurements were made with a newly-introduced PSD plastic EJ-276, that replaces the first commercially produced EJ-299. Comparative studies conducted with the new materials and EJ-309 liquids at large scale (up to 10 cm) show that current plastics may provide scintillation and PSD performance sufficient for the replacement of liquid scintillators. Comparison to stilbene single crystals compliments the information about the status of the solid-state materials recently developed for fast neutron detection applications.

  9. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Scintillating plate calorimeter optical design

    International Nuclear Information System (INIS)

    McNeil, R.; Fazely, A.; Gunasingha, R.; Imlay, R.; Lim, J.

    1990-01-01

    A major technical challenge facing the builder of a general purpose detector for the SSC is to achieve an optimum design for the calorimeter. Because of its fast response and good energy resolution, scintillating plate sampling calorimeters should be considered as a possible technology option. The work of the Scintillating Plate Calorimeter Collaboration is focused on compensating plate calorimeters. Based on experimental and simulation studies, it is expected that a sampling calorimeter with alternating layers of high-Z absorber (Pb, W, DU, etc.) and plastic scintillator can be made compensating (e/h = 1.00) by suitable choice of the ratio of absorber/scintillator thickness. Two conceptual designs have been pursued by this subsystem collaboration. One is based on lead as the absorber, with read/out of the scintillator plates via wavelength shifter fibers. The other design is based on depleted uranium as the absorber with wavelength shifter (WLS) plate readout. Progress on designs for the optical readout of a compensating scintillator plate calorimeter are presented. These designs include readout of the scintillator plates via wavelength shifter plates or fiber readout. Results from radiation damage studies of the optical components are presented

  11. Radiation damage studies on new liquid scintillators and liquid-core scintillating fibers

    International Nuclear Information System (INIS)

    Golovkin, S.V.

    1994-01-01

    The radiation resistant of some new liquid scintillation and capillaries filled with liquid scintillators has been presented. It was found that scintillation efficiency of the scintillator based on 1-methyl naphthalene with a new R39 only by 10% at the dose of 190 Mrad and the radiation resistance of thin liquid-core scintillating was decreased fibers exceeded 60 Mrad. 35 refs

  12. Scintillators and other particle optical detectors

    International Nuclear Information System (INIS)

    Chipaux, R.

    2011-01-01

    The author reports and comments his researcher career in the field of particle optical detectors. He addresses the cases of organic scintillators (scintillating fibers, liquid scintillators), inorganic scintillators (crystals for electromagnetic calorimetry, crystals for solar neutrino spectroscopy), and Cherenkov Effect detectors. He also reports his works on Cd Te detectors and their modelling

  13. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  14. Encapsulated scintillation detector

    International Nuclear Information System (INIS)

    Toepke, I.L.

    1982-01-01

    A scintillation detector crystal is encapsulated in a hermetically sealed housing having a glass window. The window may be mounted in a ring by a compression seal formed during cooling of the ring and window after heating. The window may be chemically bonded to the ring with or without a compression seal. The ring is welded to the housing along thin weld flanges to reduce the amount of weld heat which must be applied. A thin section is provided to resist the flow of welding heat to the seal between the ring and the window thereby forming a thermal barrier. The thin section may be provided by a groove cut partially through the wall of the ring. A layer of PTFE between the tubular body and the crystal minimizes friction created by thermal expansion. Spring washers urge the crystal towards the window. (author)

  15. Properties of scintillator solutes

    International Nuclear Information System (INIS)

    Fluornoy, J.M.

    1998-06-01

    This special report summarizes measurements of the spectroscopic and other properties of the solutes that were used in the preparation of several new liquid scintillators developed at EG and G/Energy Measurements/Santa Barbara Operations (the precursor to Bechtel Nevada/Special Technologies Laboratory) on the radiation-to-light converter program. The data on the individual compounds are presented in a form similar to that used by Prof. Isadore Berlman in his classic handbook of fluorescence spectra. The temporal properties and relative efficiencies of the new scintillators are presented in Table 1, and the efficiencies as a function of wavelength are presented graphically in Figure 1. In addition, there is a descriptive glossary of the abbreviations used herein. Figure 2 illustrates the basic structures of some of the compounds and of the four solvents reported in this summary. The emission spectra generally exhibit more structure than the absorption spectra, with the result that the peak emission wavelength for a given compound may lie several nm away from the wavelength, λ avg , at the geometric center of the emission spectrum. Therefore, the author has chosen to list absorption peaks, λ max , and emission λ avg values in Figures 3--30, as being most illustrative of the differences between the compounds. The compounds, BHTP, BTPB, ADBT, and DPTPB were all developed on this program. P-terphenyl, PBD, and TPB are commercially available blue emitters. C-480 and the other longer-wavelength emitters are laser dyes available commercially from Exciton Corporation. 1 ref., 30 figs

  16. Radiation damage in plastic scintillators

    International Nuclear Information System (INIS)

    Majewski, S.

    1990-01-01

    Results of radiation damage studies in plastic scintillators are reviewed and critically analyzed from the point of view of applications of plastic scintillators in calorimetric detectors for the SSC. Damage to transmission and to fluorescent yield in different conditions is discussed. New directions in R ampersand D are outlined. Several examples are given of the most recent data on the new scintillating materials made with old and new plastics and fluors, which are exhibiting significantly improved radiation resistance. With a present rate of a vigorous R D programme, the survival limits in the vicinity of 100 MRad seem to be feasible within a couple of years

  17. Detection of Beta-rays by using Plastic Scintillating Fibers

    International Nuclear Information System (INIS)

    Park, Chan Hee

    2005-02-01

    Optical fibers have been used as sensing materials in various nuclear applications. Optical fiber sensors have proven to present several advantages as compared with other conventional sensors. They can be prepared in very small sizes and they are light enough to be easily put into very narrow channels such as between nuclear to be easily put into very narrow channels such as between nuclear fuel rods. No electrical power is needed to the sensor part so they are less susceptible to troubles in harsh environments such as underground and underwater. Optical fiber sensors cost relatively cheap to make, so that they are more suitable for multi-point radiation monitoring such as in nuclear power plants, accelerators, fusion study facilities. If one develops radiation sensors using scintillating optical fibers, that can directly measure the concentration of 3 H or 14 C in radioactive liquid, they can be useful tools to substitute the current liquid scintillation counters. They can be also used to measure the radioactivity of liquid radioactive wastes by dipping into the liquid wastes. Recently, several new scintillating materials of high density and low hygroscopicity have been found, and they can be transformed into good radiation-detection tools when they are combined with optical fibers. In this study, we have used commercially available plastic scintillating fibers of Bicron model BCF-12 (0.5mm, 1mm in diameter) to detect beta rays emitted from 3 H, 14 C. Several types of radiation sensors were constructed : each was constructed with thirty strands of the fibers being packed an aluminum tube. The optical signals generated inside the fiber bundle were converted into electrical pluses by a photomultiplier tube(PMT). The pulses were counted either through a non-coincidence circuit or a coincidence circuit. Two types of sensors were constructed for the non-coincidence counting. The open type (sensor A) is a sensor for which one end of the fibers is open and the other end

  18. Characterization of Ca co-doped LSO:Ce scintillators coupled to SiPM for PET applications

    International Nuclear Information System (INIS)

    Bisogni, M.G.; Collazuol, G.M.; Marcatili, S.; Melcher, C.L.; Del Guerra, A.

    2011-01-01

    Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic number of the crystal; a fast light signal that allows to achieve a good time resolution and to cope with high counting rates; a high light yield for a good energy and time resolution; a good linearity of the light output as a function of the energy to preserve the intrinsic energy resolution of the scintillator. Recently developed LSO:Ce scintillators, co-doped with Ca, have been produced by the University of Tennessee group. They are characterized by the improved performance of most the above-mentioned characteristics. The crystals, initially tested with PMTs, showed a higher light output, faster light pulse, improved energy resolution and reduced afterglow, as compared to the standard LSO:Ce crystals. Even though the PMTs still represent the gold standard photodetectors, the recently available SiPMs are now valid candidate to replace PMTs in the next generation of PET scanners thanks to their compactness, high spatial resolution performances, low bias operating voltage and, most important for combined PET/MRI systems, insensitivity to static and RF fields. In this work we present the performance of Ca co-doped LSO:Ce samples coupled to SiPMs and PMTs. In particular we have assessed their performances by evaluating the energy and time resolution.

  19. Application of a free parameter model to plastic scintillation samples

    Energy Technology Data Exchange (ETDEWEB)

    Tarancon Sanz, Alex, E-mail: alex.tarancon@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Kossert, Karsten, E-mail: Karsten.Kossert@ptb.de [Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany)

    2011-08-21

    In liquid scintillation (LS) counting, the CIEMAT/NIST efficiency tracing method and the triple-to-double coincidence ratio (TDCR) method have proved their worth for reliable activity measurements of a number of radionuclides. In this paper, an extended approach to apply a free-parameter model to samples containing a mixture of solid plastic scintillation microspheres and radioactive aqueous solutions is presented. Several beta-emitting radionuclides were measured in a TDCR system at PTB. For the application of the free parameter model, the energy loss in the aqueous phase must be taken into account, since this portion of the particle energy does not contribute to the creation of scintillation light. The energy deposit in the aqueous phase is determined by means of Monte Carlo calculations applying the PENELOPE software package. To this end, great efforts were made to model the geometry of the samples. Finally, a new geometry parameter was defined, which was determined by means of a tracer radionuclide with known activity. This makes the analysis of experimental TDCR data of other radionuclides possible. The deviations between the determined activity concentrations and reference values were found to be lower than 3%. The outcome of this research work is also important for a better understanding of liquid scintillation counting. In particular the influence of (inverse) micelles, i.e. the aqueous spaces embedded in the organic scintillation cocktail, can be investigated. The new approach makes clear that it is important to take the energy loss in the aqueous phase into account. In particular for radionuclides emitting low-energy electrons (e.g. M-Auger electrons from {sup 125}I), this effect can be very important.

  20. [Corrected count].

    Science.gov (United States)

    1991-11-27

    The data of the 1991 census indicated that the population count of Brazil fell short of a former estimate by 3 million people. The population reached 150 million people with an annual increase of 2%, while projections in the previous decade expected an increase of 2.48% to 153 million people. This reduction indicates more widespread use of family planning (FP) and control of fertility among families of lower social status as more information is being provided to them. However, the Ministry of Health ordered an investigation of foreign family planning organizations because it was suspected that women were forced to undergo tubal ligation during vaccination campaigns. A strange alliance of left wing politicians and the Roman Catholic Church alleges a conspiracy of international FP organizations receiving foreign funds. The FP strategies of Bemfam and Pro-Pater offer women who have little alternative the opportunity to undergo tubal ligation or to receive oral contraceptives to control fertility. The ongoing government program of distributing booklets on FP is feeble and is not backed up by an education campaign. Charges of foreign interference are leveled while the government hypocritically ignores the grave problem of 4 million abortions a year. The population is expected to continue to grow until the year 2040 and then to stabilize at a low growth rate of .4%. In 1980, the number of children per woman was 4.4 whereas the 1991 census figures indicate this has dropped to 3.5. The excess population is associated with poverty and a forsaken caste in the interior. The population actually has decreased in the interior and in cities with 15,000 people. The phenomenon of the drop of fertility associated with rural exodus is contrasted with cities and villages where the population is 20% less than expected.