WorldWideScience

Sample records for scintigraphy detects impaired

  1. Metaiodobenzylguanidine [131I] scintigraphy detects impaired myocardial sympathetic neuronal transport function of canine mechanical-overload heart failure

    International Nuclear Information System (INIS)

    Rabinovitch, M.A.; Rose, C.P.; Rouleau, J.L.

    1987-01-01

    In heart failure secondary to chronic mechanical overload, cardiac sympathetic neurons demonstrate depressed catecholamine synthetic and transport function. To assess the potential of sympathetic neuronal imaging for detection of depressed transport function, serial scintigrams were acquired after the intravenous administration of metaiodobenzylguanidine [ 131 I] to 13 normal dogs, 3 autotransplanted (denervated) dogs, 5 dogs with left ventricular failure, and 5 dogs with compensated left ventricular hypertrophy due to a surgical arteriovenous shunt. Nine dogs were killed at 14 hours postinjection for determination of metaiodobenzylguanidine [ 131 I] and endogenous norepinephrine content in left atrium, left ventricle, liver, and spleen. By 4 hours postinjection, autotransplanted dogs had a 39% reduction in mean left ventricular tracer accumulation, reflecting an absent intraneuronal tracer pool. Failure dogs demonstrated an accelerated early mean left ventricular tracer efflux rate (26.0%/hour versus 13.7%/hour in normals), reflecting a disproportionately increased extraneuronal tracer pool. They also showed reduced late left ventricular and left atrial concentrations of tracer, consistent with a reduced intraneuronal tracer pool. By contrast, compensated hypertrophy dogs demonstrated a normal early mean left ventricular tracer efflux rate (16.4%/hour) and essentially normal late left ventricular and left atrial concentrations of tracer. Metaiodobenzylguanidine [ 131 I] scintigraphic findings reflect the integrity of the cardiac sympathetic neuronal transport system in canine mechanical-overload heart failure. Metaiodobenzylguanidine [ 123 I] scintigraphy should be explored as a means of early detection of mechanical-overload heart failure in patients

  2. Detection of the myocardium ischemia in scintigraphy

    International Nuclear Information System (INIS)

    Faraggi, M.; Pierquet-Ghazzar, N.; Maunoury, C.

    2005-01-01

    The myocardium scintigraphy (SPECT) gives excellent elements of prognosis allowing to select at the best, the patients having a revascularization, and then an angiography examination. It appears complementary of the coronaries tree imaging and should (in theory) be practised in first in an organisation chart of taking over. In the search of practicable myocardium, the PET with 18 FDG, although being competitive, is more and more forsaken to the MRI profit. In retaliation, the PET with 82 Rb with test of pharmacology stimulation could develop in detection of coronaries disease. (N.C.)

  3. Twenty cases of ectopic thyroid gland detected by thyroid scintigraphy

    International Nuclear Information System (INIS)

    Hashimoto, Teisuke; Kubo, Atsushi; Hashimoto, Shozo

    1988-01-01

    20 cases of ectopic thyroid gland were detected out of 5,261 thyroid scintigraphy from 1973. Except for 1 case, all cases were female. Considering of thyroid function, 11 cases were euthyroid and rest of 9 cases were hypothyroid function. Clinical symptom of hypothyroid cases were mainly retarded linear growth and high value of serum TSH and in case of euthyroid cases were sublingual tumor and fullness or tightness in throat. Thyroid scintigraphy is very useful to diagnose the sublingual tumor whether it is ectopic thyroid gland or not. In case of congenital hypothyroidism children, ectopic thyroid gland causing hypothyroidism is definitely diagnosed by thyroid scintigraphy. (author)

  4. Value of transoperative scintigraphy in the detection of accessory spleens

    International Nuclear Information System (INIS)

    Sezeur, A.; Goujard, F.; Labriolle-Vaylet, C.L. de; Wioland, M.; Douay, L.; Desmarquet, J.

    1990-01-01

    A case of accessory spleen, 1 cm in diameter, responsible for recurrence of an idiopathic thrombocytopenic purpura after splenectomy is reported. This case is original in that the accessory spleen could only be detected by transoperative scintigraphy. Transoperative scintigraphy is a simple method to be used when one or several unrecognized accessory spleens are responsible for recurrence of a blood disease after excision of the principal spleen [fr

  5. Detectability of metastatic bone tumor by Ga-67 scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu; Hihara, Toshihiko; Ogata, Hitoshi; Monzawa, Shuichi; Kachi, Kenji; Matsusako, Masaki

    1989-01-01

    Ga-67 scintigrams in patients with malignant diseases sometimes reveal uptake of the tracer in the bone metastases. Detectability of Ga-67 scintigraphy for metastatic bone tumors and benign bone lesions was compared with that of Tc-99m bone scintigraphy. Countable bone metastases detected by bone scintigraphy were evaluated whether the lesion showed apparent, faint, or negative Ga-67 uptake. Of 47 lesions 23 (49%) showed apparent uptake and 17 (36%) showed negative uptake, only 7 (10%) mostly fracture/osteotomy, showed apparent uptake of the tracer. Uptake in the other benign lesions such as trauma of the ribs, spondylosis deformans, and arthrosis deformans was rather faint. In patients with multiple bone metastases, 9 patients (82%) out of 11 showed more prominent abnormal findings in Tc-99m MDP bone scintigraphy than in Ga-67 scintigraphy; that is, Ga-67 scintigraphy was not able to reveal all metastatic bone lesions. In patients with untreated or recurrent tumors, relation between Ga-67 uptake in the tumors and that in the bone metastases was evaluated. Of 7 patients with negative Ga-67 uptake in the bone metastases; that is, there seemed to be little relation between Ga-67 affinity to the primary tumors and that to the bone metastases. Mechanisms of the Ga-67 uptake in the bone metastases were discussed. Not only the tumor cells or tissues in the bone metastases but also bone mineral or osteoclasts might be the deposition sites of Ga-67. (author)

  6. Detectability of metastatic bone tumor by Ga-67 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu; Hihara, Toshihiko; Ogata, Hitoshi; Monzawa, Shuichi; Kachi, Kenji; Matsusako, Masaki

    1989-03-01

    Ga-67 scintigrams in patients with malignant diseases sometimes reveal uptake of the tracer in the bone metastases. Detectability of Ga-67 scintigraphy for metastatic bone tumors and benign bone lesions was compared with that of Tc-99m bone scintigraphy. Countable bone metastases detected by bone scintigraphy were evaluated whether the lesion showed apparent, faint, or negative Ga-67 uptake. Of 47 lesions 23 (49%) showed apparent uptake and 17 (36%) showed negative uptake, only 7 (10%) mostly fracture/osteotomy, showed apparent uptake of the tracer. Uptake in the other benign lesions such as trauma of the ribs, spondylosis deformans, and arthrosis deformans was rather faint. In patients with multiple bone metastases, 9 patients (82%) out of 11 showed more prominent abnormal findings in Tc-99m MDP bone scintigraphy than in Ga-67 scintigraphy; that is, Ga-67 scintigraphy was not able to reveal all metastatic bone lesions. In patients with untreated or recurrent tumors, relation between Ga-67 uptake in the tumors and that in the bone metastases was evaluated. Of 7 patients with negative Ga-67 uptake in the bone metastases; that is, there seemed to be little relation between Ga-67 affinity to the primary tumors and that to the bone metastases. Mechanisms of the Ga-67 uptake in the bone metastases were discussed. Not only the tumor cells or tissues in the bone metastases but also bone mineral or osteoclasts might be the deposition sites of Ga-67.

  7. Early detection of infantile endocarditis by gallium-67 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Hardoff, R; Luder, A S; Lorber, A; Dembo, L

    1989-04-01

    An infant with suspected soft tissue infection of the knee was studied by /sup 67/Ga-scintigraphy. In addition to knee and hip joint increased activity, heart uptake was also demonstrated prior to the development of clinical signs of endocarditis. The early detection and treatment resulted in satisfactory clinical resolution.

  8. Early detection of infantile endocarditis by gallium-67 scintigraphy

    International Nuclear Information System (INIS)

    Hardoff, R.; Luder, A.S.; Lorber, A.; Dembo, L.; Technion-Israel Inst. of Tech., Haifa. Faculty of Medicine)

    1989-01-01

    An infant with suspected soft tissue infection of the knee was studied by 67 Ga-scintigraphy. In addition to knee and hip joint increased activity, heart uptake was also demonstrated prior to the development of clinical signs of endocarditis. The early detection and treatment resulted in satisfactory clinical resolution. (orig.)

  9. Bone scintigraphy for metastasis detection in canine osteosarcoma

    International Nuclear Information System (INIS)

    Forrest, L.J.; Thrall, D.E.

    1994-01-01

    The purpose of this study was to assess the usefulness of serial bone scintigraphy in the detection of skeletal and extraskeletal metastases in dogs with appendicular osteosarcoma. Twenty-six dogs with primary, appendicular osteosarcoma were entered into a limb-sparing protocol. Bone scintigraphy was performed upon presentation, after neoadjuvant therapy but prior to surgery and at selective intervals after limb-sparing surgery to evaluate for the presence of metastasis. Thoracic radiographs, and radiographs of other sites, were also made at the time of each bone scan. All dogs had a complete necropsy. No dog had bone or lung metastases detected prior to treatment. The bone scans, medical records, and radiographs of each dog were reviewed retrospectively. All but one dog developed metastatic disease. Bone metastatic sites were confirmed at necropsy in 12 of the 26 dogs. Seven of these 12 dogs had bone metastatic sites which were not producing clinical signs, i.e. an occult metastasis. In five of the seven dogs, the occult site was the first metastatic site detected. Extraskeletal metastases were identified scintigraphically in six of the 26 dogs, but these were clinically apparent prior to bone scintigraphy in each dog. Suspected malignant scintigraphic lesions were proven benign in six dogs. In five dogs with malignant bone lesions at necropsy the last bone scan prior to euthanasia was normal. The time interval between scintigraphy and necropsy was variable in these five dogs. All dogs without bone metastases at necropsy had normal bone scans. This study validates the usefulness of bone scintigraphy for detection of occult bone metastasis and improved ability for tumor staging in dogs with appendicular osteosarcoma

  10. Detection of thrombi by 111In-oxine platelet scintigraphy

    International Nuclear Information System (INIS)

    Makino, Katsutoshi; Yamamuro, Masashi; Ichikawa, Takehiko; Futagami, Yasuo; Konishi, Tokuji; Nakano, Takeshi; Takezawa, Hideo

    1985-01-01

    For 52 patients with cardiac disease and 11 patients with vascular disease, In-111-oxine platelet scintigraphy was performed to assess its clinical usefulness for detecting thrombi. Using Hayashida's method, platelets were separated in 43 ml peripheral blood, washed and labeled with 1 mCi In-111-oxine. In addition to planar images in the anterior, 45 deg left anterior oblique and left lateral views, single photon emission computed tomography (SPECT) was performed in some cases by rotating a dual gamma camera 24 and 72 hours after labeled platelet injection. The functions of platelet and coagulability were examined 36 hours after the injection of labeled platelets. Medical therapy was not changed during this study. Intracardiac thrombi were documented in 16 of 52 cases with cardiac disease and intravascular thrombi in 10 cases with vascular disease by angiography, CT and two-dimensional echocardiography. Positive images were obtained in 10 cases with cardiac disease and in eight cases with vascular disease by scintigraphy. Therefore, sensitivity, specificity, and overall accuracy were 63 %, 100 % and 88 % in intracardiac thrombi; 80 %, 100 % and 82 % in intravascular thrombi; and totally 69 %, 100 % and 87 %, respectively. In the detection of intracardiac thrombi by scintigraphy, the sensitivity seemed to be lower and the specificity higher than those by other graphic studies. In 52 cases with cardiac disease, five out of six cases with false negative images had received antiplatelet and/or anticoagulant drugs, and in these cases, platelet and coagulation functions tended to be decreased compared with those of true positive cases or true negative cases. We conclude that positive images in scintigraphy indicate the existence of growing thrombi, and that In-111-oxine platelet scintigraphy has clinical usefulness, not only for detecting thrombi, but for estimating platelet activity and effect of medical therapy. (author)

  11. Incidental Hiatal Hernia Detected with Meckel's Scintigraphy

    International Nuclear Information System (INIS)

    Aksoy, Tamer; Kiratli, Pinar Ozgen

    2011-01-01

    Congenital hiatal hernia (CHH) in children is a very rare condition that occurs in about 1 in every 2,000 to 5,000 live births, with a male to female ratio of 2:3. In 97% of cases the anomaly is unilateral with a left side preponderance. The hernia content can include the stomach, bowel loops, spleen or part of the liver. CHH may remain asymptomatic or induce only nonspecific gastro intestinal and/or thoracic symptoms. The symptomatology og these patients is usually non specific, in the form of repeated attacks of chest infection and/or recurrent vomiting, but can be associated with serious complications such as intrathoracic gastric volvulus with incarceration and strangulation. Because of the gastroesophageal reflux, linear ulcerations on the esophageal mucosa might occur and cause intermittent bleeding. Plan chest radiographs, AP and lateral, may raise a suspicion of the condition, while upper gastrointestinal contrast series are diagnostic. The treatment is surgery consisting of excision of the hernial sac after reducing the stomach and repair of the diaphragmatic defect by tightening the crura of the esophageal hiatus. If the defect is large and associated with displacement of the gastroesophageal junction (GEJ) into the thorax, adding an anti reflux procedure to the repair is appropriate. This can be achieved transabdominally either by laparotomy or laparoscopically. To the best of our knowledge, this is the second case diagnosed with Meckel's scintigraphy.

  12. The role of bone scintigraphy in detecting child abuse.

    Science.gov (United States)

    Conway, J J; Collins, M; Tanz, R R; Radkowski, M A; Anandappa, E; Hernandez, R; Freeman, E L

    1993-10-01

    This review of diagnostic imaging in cases of suspected child abuse characterizes the significant differences between bone scintigraphy and x-ray evaluation, describes the advantages and disadvantages of each modality, postulates on the specific mechanisms of injury that produce the characteristic scintigraphic findings, and emphasizes the influences that scintigraphic studies have on the medical, social, and legal aspects of child abuse. The major advantages of bone scintigraphy are its increased sensitivity (25% to 50%) in detecting evidence of soft tissue as well as bone trauma in child abuse. Furthermore, it is postulated that the specific mechanisms of inflicting the trauma relate to the patient's size and are characterized by bone scintigraphy. During fits of anger or frustration, the perpetrator of child abuse grasps the small infant or child by the thorax during the shaking activity. This produces characteristic rib injuries. The older and heavier child is more likely to be grabbed by the extremities, which produces periosteal injuries manifested as characteristic abnormal localizations in the diaphyses of the extremities. The roentgenograms of these injuries are frequently normal. The importance of bone scintigraphy is its complementary nature in defining and characterizing the extent and severity of trauma from child abuse. Such findings have direct bearing on the medical, social, and legal outcomes for the abused child. The quality of scintigraphic imaging is important, requiring the use of magnification techniques in the infant. The interpretation of the scintigraphic images depends on an understanding of the mechanisms by which the radionuclide localizes in bone. The same traumatic incident can lead to decreased, normal, or increased localization at the trauma site. Radionuclide scintigraphy is a complementary rather than competitive imaging modality to X-ray evaluation in the diagnosis and management of physical child abuse.

  13. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    . Cardiac amyloidosis is often under diagnosed due to unspecific and varied signs and symptoms. The diagnosis is confirmed by endomyocardial biopsy, an invasive procedure with inherent risks to this technique. Pyrophosphate-{sup 99m}Tc scintigraphy is a simple, non-invasive, low cost, with good sensitivity method for detection of cardiac amyloidosis. The scintigraphy pattern observed in cardiac amyloidosis cases is abnormal diffuse tracer uptake in both heart ventricles. Planar and/or tomographic imaging may be performed. It is considered a highly sensitive test, with low rates of false-negative results despite the existing little literature. Therefore the scintigraphy can be useful to select patients for biopsy. Conclusion: Scintigraphy can be of great assistance in cardiac amyloidosis, despite its low specificity. Due to its high sensibility, it can be a useful test to early discriminate patients who should undergo biopsy, allowing treatment optimization. (author)

  14. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    International Nuclear Information System (INIS)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C.

    2008-01-01

    amyloidosis is often under diagnosed due to unspecific and varied signs and symptoms. The diagnosis is confirmed by endomyocardial biopsy, an invasive procedure with inherent risks to this technique. Pyrophosphate- 99m Tc scintigraphy is a simple, non-invasive, low cost, with good sensitivity method for detection of cardiac amyloidosis. The scintigraphy pattern observed in cardiac amyloidosis cases is abnormal diffuse tracer uptake in both heart ventricles. Planar and/or tomographic imaging may be performed. It is considered a highly sensitive test, with low rates of false-negative results despite the existing little literature. Therefore the scintigraphy can be useful to select patients for biopsy. Conclusion: Scintigraphy can be of great assistance in cardiac amyloidosis, despite its low specificity. Due to its high sensibility, it can be a useful test to early discriminate patients who should undergo biopsy, allowing treatment optimization. (author)

  15. Evaluation of Tl-201 lung uptake and impairment of pulmonary perfusion on scintigraphies in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Koizumi, Tomonori; Kubo, Keishi

    2000-01-01

    Tl-201 lung uptake in 74 patients (85 lesions) and pulmonary perfusion in 105 patients were studied to evaluate clinical usefulness of Tl-201 lung uptake and perfusion lung scintigraphy in pulmonary tuberculosis, using a scintillation camera with a mini-computer system. As indices of Tl-201 lung uptake, lung (lesion) to upper mediastinum uptake ratio (L/M) and visual grading were used. L/M in pulmonary tuberculosis was 1.96±0.66, which was significantly larger than 1.04±0.24 in healthy controls and lower than that in heart diseases with left heart failure and idiopathic interstitial pneumonia, and showed no significant differences with that in acute pneumonia, pyothorax, primary lung cancer and malignant mediastinal tumor. L/M in pulmonary tuberculosis did not correlate with CRP, erythrocyte sedimentation rate, Gaffky number of sputum and body temperature. It correlated with the type of pulmonary tuberculosis according to the Gakken Classification reflecting the disease activity. It was larger in the exudative type, caseo-infiltrative one, disseminated one, one with cavity in infiltrative lesion than the fibro-caseous one. On perfusion lung scintigram, impairment of pulmonary perfusion larger than area of the entire unilateral lung was observed in 68 cases (64.8%). Area of hypoperfused lung field, which correlated with % vital capacity (r=0.60, p=0.0002) and PaO 2 (r=0.39,p=0.0024), was significantly larger in patients with silicosis and those with bilateral pleural involvements such as pleural callosity than in those with type III according to the Gakkai Classification. Most of the patients showed decreased pulmonary perfusion and Tl-201 accumulation of which grade reflects the disease activity in active tuberculous lesion. Patients with miliary tuberculosis and those with silicotuberculosis showed diffuse Tl-201 accumulation in the both lungs. Tl-201 lung scintigraphy seems to be useful for visualizing active tuberculous lesions, particularly the ones that

  16. Comparison of whole body MR diffusion weighted imaging and skeletal scintigraphy in detecting bone metastasis

    International Nuclear Information System (INIS)

    Xu Xian; Ma Lin; Zhang Jinshan; Cai Youquan; Cheng Liuquan; Guo Xinggao; Xu Baixuan

    2008-01-01

    Objective: To evaluate the application of whole body MR diffusion weighted imaging (DWI) in the detection of bone metastasis using skeletal scintigraphy as the reference. Methods: Forty-two healthy volunteers and 38 patients with malignant tumors were enrolled in our study. All the patients received MR examination and skeletal scintigraphy within one week. MR examination was performed on GE signa 3.0T MR scanner using a build-in body coil. The skeletal system was divided into eight regions and the images of the whole body MR DWI and skeletal scintigraphy were reviewed to compare the two modalities patient by patient and region by region. The images were reviewed separately by two radiologists and two nuclear medicine physicians, who were blinded to the results of another imaging modality. Results: A total of 169 metastatic lesions in 69 regions of 30 patients were detected by whole body MR DWI while 156 lesions in 68 regions of 29 patients were identified by skeletal scintigraphy. There were two cases negative in scintigraphy but positive in whole body MR DWI and one case positive in scintigraphy only. There were eight lesions negative in scintigraphy but positive in whole body MR DWI, mainly located in the spine, pelvis and femur. Seven lesions were only detected by scintigraphy, mainly located in the skull, sternum, clavicle and scapula. Conclusion: The whole body MR DWI reveals excellent consistency with skeletal scintigraphy regarding bone metastasis, and the two modalities are complementary for each other. (authors)

  17. Pelvic and lumbar metastasis detected by bone scintigraphy in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Ruiz Hernandez, G.; Castillo Pallares, F.J.; Llorens Banon, L.; Romero de Avila y Avalos, C.; Garcia Garc'ia, T.; Azagra Ros, P.; Maruenda Paulino, J.I.; Ferrer Albiach, C.

    1999-01-01

    A case of a 43-year-old man suffering from pleural mesothelioma with distant bone metastasis is reported. The results of bone scintigraphy and NMR findings allowed the diagnosis. The current case describes a hematogenous metastasis to the pelvis and vertebral column from a malignant pleural mesothelioma that was detected initally by bone scintigraphy. (orig.) [de

  18. Clinical experience of 123I-IMP scintigraphy in detecting vertebral bone metastases of hepatocellular carcinoma. A comparison with bone scintigraphy with 99mTc-MDP

    International Nuclear Information System (INIS)

    Suto, Y.; Iwamiya, T.; Tanigawa, N.; Shabana, M.; Ohta, Y.

    1994-01-01

    123 I-IMP and bone scintigraphy with 99m Tc-MDP were consecutively performed in patients with vertebral bone metastases from hepatocellular carcinoma and lumbar spondylosis deformans in a 7-day interval or shorter. The intensity of uptake was compared. Eighteen of the 20 metastatic lesions (90%) were classified as increased uptake areas in 123 I-IMP scintigraphy. MDP-scintigraphy disclosed 16 metastatic lesions (80%), 9 as ''hot'' lesions (56%) and 7 as ''cold'' lesions (44%). 123 I-IMP scintigraphy was negative in all 12 lesions of lumbar spondylosis deformans. Compared to MDP-scintigraphy, 123 I-IMP scintigraphy was more sensitive in detecting vertebral bone metastases of hepatocellular carcinoma with smaller rates of false-positive and false-negative findings. (orig./MG)

  19. Sodium pertechnetate scintigraphy in detection of Meckel's diverticulum

    DEFF Research Database (Denmark)

    Poulsen, K A; Qvist, N

    2000-01-01

    OBJECTIVE: To evaluate the results of 99mTc-Na-pertechnetate scintigraphy in children presenting with symptoms suspicious of Meckel's diverticulum (MD). METHOD: Retrospective study. A total of 55 99mTc-Na-pertechnetate scintigraphies in 53 patients were compared with the results from surgery and ...

  20. The usefulness of bone marrow scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Morita, Rikushi

    1985-01-01

    A combination study of bone and bone marrow scintigraphy was performed on 25 pts with prostatic cancer, and, in order to study the usefulness in the diagnosis of bone metastasis, the findings of 2 scintigraphies were compared with those of skeletal roentgenography. Out of the 18 cases with the hot spots of sup(99m)Tc-MDP in the lower lumbar spine or/and the pelvic bone, 8 showed normal bone marrow scintigrams which were eventually proved to have degenerative changes of the spine accompanied by aging. On the other hand, nine cases of the ten, who had accumulation defects on the bone marrow scintigrams were finally proved having bone metastasis. All six cases with extensive bone metastases shown by bone scintigraphy with sup(99m)Tc-MDP, demonstrated multiple accumulation defects on bone marrow scintigraphy with sup(99m)Tc-sulfur colloid. In conclusion, bone marrow scintigraphy was thought to be helpful in distinguishing the metastatic lesions from the benign spinal degenerative changes in the cases with suspicions bone involvement and in evaluating equivocal lesions in the pelvis. Therefore, it was shown that, in the detection and diagnosis of bone metastasis from prostatic cancer, bone scintigraphy alone was insufficient, and that combination with bone marrow scintigraphy was found to be useful. (author)

  1. Isoproterenol stress thallium scintigraphy for detecting coronary artery disease

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi; Iida, Kaname; Sugishita, Yasuro; Ito, Iwao; Takeda, Tohru; Toyama, Hinako; Akisada, Masayoshi

    1989-01-01

    The present study was undertaken to assess the diagnostic value of isoproterenol (ISP) thallium scintigraphy. The findings were compared with those of ISP-ECG and exercise thallium scintigraphy. The study population consisted of 24 patients who had a history of chest pain without previous myocardial infarction. ISP was given at increasing doses of 0.02, 0.04, 0.08 μg/mg/min at 3-minutes intervals, and was terminated for any of the following reasons: angina, significant arrhythmia, significant ST segment depression, or target heart rate. Thallium scintigrams were obtained immediately after terminating ISP infusion, and after a 3-hour delay, redistribution scans were obtained. Scintigrams were considered positive when a reversible defect was present. After stress tests, coronary angiography was performed. According to the presence or absence of significant coronary artery stenosis, the patients were divided into coronary artery disease (CAD) group (n=12) and so-called normal coronary (NC) group (n=12). Among 12 patients in the CAD group, ISP induced anginal pain in six (50%), and ISP-ECT and ISP thallium scintigraphy were positive in 10 (83%) and in 11 (92%), compared with four(33%), four(33%) and two (17%) in the NC group. These data indicate that ISP-ECG had a sensitivity of 83%, a specificity of 67%, and a diagnostic accuracy of 75%; and the corresponding figures for ISP thallium scintigraphy were 92%, 83%, and 88%. Among nine patients who underwent both ISP thallium scintgraphy and exercise thallium scintigraphy, all patients, except for one false negative case on ISP thallium scintigraphy, were correctly diagnosed. No serious complications occurred in association with the ISP infusion test. ISP thallium scintigraphy was considered to be a safe, sensitive, and specific method for diagnosing CAD when exercise tests were intolerable. (N.K.)

  2. Detection of common bile duct stone by hepatobiliary scintigraphy

    International Nuclear Information System (INIS)

    Itoh, Hisao; Sakai, Toyohiko; Takahashi, Norio

    1991-01-01

    Hepatobiliary scintigraphy and direct X-ray cholangiography were compared in 29 patients with common bile duct (CBD) stones confirmed at surgery. The scintigraphic findings included no visualization of the biliary system (NV), pooling of bile in the biliary system (PB), prolonged transit time over 60 min (PTT), filling defect in the CBD image (FD), and reflux of bile toward the intrahepatic ducts after gallbladder stimulation (RB). The positive rates of NV, PB, PTT, FD, and RB in patients with CBD stones were 7%, 31%, 17%, 48%, and 14%, respectively. One or more of these five findings was found in 83%. Although the NV was a useful finding suggesting complete obstruction of the CBD, it shared little in the diagnosis of CBD stone. The positive rate of the PB was relatively high and it would be a useful finding as an indication of the presence of passage disturbance of the CBD. The PB was usually accompanied by the FD. The PTT had some usefulness in the detection of incomplete obstruction of the CBD in patients with a visualized gallbladder. In patients with no visualization of the gallbladder, however, the transit time tended to be shorter than that of gallbladder visualized patients. Therefore, the judgement of PTT in patients with no visualized gallbladder needed another criteria. The FD was the most frequent among the five findings and the sites of FD correlated well with CBD stones on direct X-ray cholangiography. The FD would be a reliable finding indicating CBD stone or CBD stenosis. Although the RB was a finding limited in patients with a visualized gallbladder, it seemed to be a helpful findings for the detection of CBD stone in patients with a mildly dilated CBD. (author)

  3. Correlation of immunosuppression scheme with renal graft complications detected by dynamic renal scintigraphy

    International Nuclear Information System (INIS)

    Martins, Flavia Paiva Proenca; Gutfilen, Bianca

    2001-01-01

    Dynamic renal scintigraphy allows the diagnosis of complications in patients submitted to organ transplantation, such as perfusion abnormalities, acute tubular necrosis and rejection. In this study we employed 99m Tc-DTPA scintigraphy to study patients submitted to kidney transplantation. The results obtained and the clinical findings were conjunctively analyzed in order to detect graft rejection or other complications. The type of immunosuppressive scheme used was also correlated with the observed complications. Fifty-five patients submitted to kidney transplantation from 1989 to 1999 were evaluated. All patients with nephrotoxicity received a 3-drug immunosuppressive scheme. In this study, acute rejection was the most frequent complication (40.4%) observed following transplantation. Thirteen of 15 recipients of cadaveric kidney grafts presented acute tubular necrosis. Only one false-positive case was observed when scintigraphy and clinical findings were not concordant. We suggest carrying out renal scintigraphy to follow-up post-transplantation patients. (author)

  4. Cold metastases detected by bone scintigraphy in aggressive lung cancer

    International Nuclear Information System (INIS)

    Martinez Carsi, C.; Perales Vila, A.; Ruiz Hernandez, G.; Sanchez Marchori, C.; Oro Camps, J.

    1998-01-01

    A case of a 55-year-old man was remitted to Traumatology Department to present back pain of two weeks of evolution. The results of bone scintigraphy and the patient's evolution allowed the diagnosis. This case report and a literature review showed the importance of using a routine bone scan in diagnosis of bone metastases. (orig.) [de

  5. Thallium 201 Exercise Scintigraphy for Detection of Multivessel Coronary Artery Disease After Transmural Myocardial Infarction

    Science.gov (United States)

    Ahmadpour, Hedayatolah; Siegel, Michael E.; Colletti, Patrick; Haywood, L. Julian

    1984-01-01

    Fifty patients with prior transmural myocardial infarction were studied with cardiac catheterization, coronary angiography, and thallium 201 exercise perfusion scintigraphy. Obstructive coronary disease involved two or three vessels in 37 patients. The sensitivity of a positive electrocardiographic test during exercise for detecting multivessel coronary disease was only 40 percent (15/37), and the sensitivity of a reversible defect on 201Tl perfusion scintigraphy was 48 percent (18/37). The combination of exercise testing and 201Tl scintigraphy detected multivessel coronary disease in 75 percent (28/37) (P < .05). New perfusion defects occurred in 61 percent (13/21) of patients with inferior myocardial infarction and multivessel coronary disease whereas it occurred in only 35 percent (5/14) of patients with prior anterior infarction and multivessel coronary disease (P < .05). 201Tl exercise perfusion scintigraphy appears to be more sensitive for detecting significant multivessel coronary disease in the presence of previous inferior infarction compared with previous anterior infarction. Combined graded exercise testing and 201Tl perfusion scintigraphy can reliably detect the presence of significant multivessel coronary disease after transmural myocardial infarction. ImagesFigure 3 PMID:6512876

  6. Detection of Metastases of Primary Hepatocellular Carcinoma with {sup 99m}Tc-HIDA Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Dae Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of); Hong, Kee Suk; Hong, Seong Woon; Lee, Jhin Oh; Kang, Tae Woong [Cancer Reseach Hospital, Korea Advanced Energy Institute, Seoul (Korea, Republic of)

    1983-03-15

    {sup 99m}Tc-Sulfur Colloid is concentrated in Kupffer cells of the liver, whereas the new biliary agents such as {sup 99m}Tc-HIDA are processed by hepatic parenchymal cells. The distant metastatic lesions in skull and lung of the primary hepatocellular carcinoma in 38-year old Korean male were detected with {sup 99m}Tc-HIDA scintigraphy. The chest PA, skull bone X-ray and radionuclide scintigraphic studies are illustrated. This observation suggests that {sup 99m}Tc-HIDA scintigraphy is useful for detection of distant metastases of primary hepatocellular carcinoma.

  7. Gastroesophageal scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Malmud, L.S.; Fisher, R.S.

    1980-01-01

    The technique of gastroesophageal scintigraphy was developed in order to quantitatively detect reflux from the stomach into the esophagus. The scintigraphic technique was compared to previous diagnostic tests. None of the other techniques is as sensitive as gastroesophageal scintigraphy for the detection of reflux, in comparison to the acid reflux test. Gastroesophageal scintigraphy is able to detect gastroesophageal reflux acurately, rapidly, noninvasively, and more sensitively than other diagnostic techniques. In addition, it is able to be employed to quantitate reflux and is suitable for studying the effects of various therapeutic modalities.

  8. Thyroid scintigraphy for the detection of radiation-induced thyroid cancer

    International Nuclear Information System (INIS)

    Puylaert, J.B.; Pauwels, E.K.; Goslings, B.M.; Van Daal, W.A.

    1985-01-01

    Thyroid scintigraphy with Tc-99m pertechnetate was performed in 249 patients who received radiation therapy for abnormalities in the head or neck in order to determine the role of this examination in the detection of abnormal nodules arising from cancer. These patients received a mean total dose of about 10.1 Gy. The mean follow-up period was 39 years. All patients underwent physical examination without prior knowledge of the scintigram. Scintigrams were evaluated without prior knowledge of the physical examination. In 158 cases, both the physical examination and scintigraphy were negative. In 64 cases, both examinations were positive. In ten patients, the physical examination was positive and scintigraphy was negative and vice versa in 17 patients. Of 249 patients, 28 ultimately underwent thyroid surgery; a total of four had carcinoma. A cost-benefit relationship as to routine scintigraphy as a screening procedure is presented. If patients are first screened by palpation, a number of abnormal nodules will be missed. In addition, a considerable number with positive palpation would probably undergo surgery unnecessarily. From a clinical and financial point of view, it is believed that scintigraphy is the examination of choice for screening for radiation-induced thyroid malignancies

  9. Utility of liver scintigraphy and angiography in preoperative detection of liver metastasis from gastrointestinal carcinoma

    International Nuclear Information System (INIS)

    Konomi, Kohki; Aso, Masakazu; Nakayama, Fumio

    1980-01-01

    One hundred and seventy cases of cancer of digestive tract were separated into three groups, advanced gastric cancer, biliary and/or pancreatic cancer and colorectal cancer. The presence of liver metastasis in each group was studied properatively by either liver scintigraphy or celiac and superior mesenteric angiography. In advanced gastric cancer and colorectal cancer, false negative ranged between 6.7 - 12.7 per cent by both scintigraphy and angiography. In biliary tract and/or pancreatic cancer, the ratio of false negative was significantly higher i.e. 18.8 - 22.6 per cent, which suggests the difficulty in diagnosing liver metastasis correctly in this group. The moist frequent occurrences of false positive either in scintigraphy or angiography were those of masses of less than 2 cm in diameter. The difference in correct diagnosis ratio for liver metastasis between scintigraphy and angiography in all three groups was only 2.9 per cent. Hence, liver scintigraphy seems to be preferable for the purpose of detecting liver metastasis prior to surgery, since further angiographical examination entails irradiation, possible complications and economic factors. (author)

  10. Utility of liver scintigraphy and angiography in preoperative detection of liver metastasis from gastrointestinal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Konomi, K; Aso, M; Nakayama, F [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1980-12-01

    One hundred and seventy cases of cancer of digestive tract were separated into three groups, advanced gastric cancer, biliary and/or pancreatic cancer and colorectal cancer. The presence of liver metastasis in each group was studied preoperatively by either liver scintigraphy or celiac and superior mesenteric angiography. In advanced gastric cancer and colorectal cancer, false negative ranged between 6.7 - 12.7 per cent by both scintigraphy and angiography. In biliary tract and/or pancreatic cancer, the ratio of false negative was significantly higher i.e. 18.8 - 22.6 per cent, which suggests the difficulty in diagnosing liver metastasis correctly in this group. The most frequent occurrences of false positive either in scintigraphy or angiography were those of masses of less than 2 cm in diameter. The difference in correct diagnosis rates for liver metastasis between scintigraphy and angiography in all three groups was only 2.9 per cent. Hence, liver scintigraphy seems to be preferable for the purpose of detecting liver metastasis prior to surgery, since further angiographical examination entails irradiation, possible complications and economic factors.

  11. Unusual Case of Occult Brucella Osteomyelitis in the Skull Detected by Bone Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Lim, Seok Tae; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Lee, Chang Seob [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2010-06-15

    Brucellosis is a worldwide infectious disease of animals that can be transmitted to humans. Osteoarticular involvement is the most common complication of brucellosis. A 47-year-old man, who was a stock breeder, complained of myalgia with fever and chills for 2 weeks. The serology titers and blood cultures for brucellosis were positive. Bone scintigraphy demonstrated a focally increased uptake in the left supra orbital area. Plain radiographs showed an osteolytic lesion, and an MRI revealed signal abnormalities in the corresponding site. We present an unusual case of occult Brucella osteomyelitis in the frontal bone of the skull detected by done scintigraphy.

  12. Pelvic and lumbar metastasis detected by bone scintigraphy in malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Hernandez, G.; Castillo Pallares, F.J.; Llorens Banon, L.; Romero de Avila y Avalos, C. [Hospital Clinic Universitari de Valencia (Spain). Servei de Medicina Nuclear; Garcia Garc`ia, T.; Azagra Ros, P. [Hospital Clinic Universitari de Valencia (Spain). Servei d`Oncologia; Maruenda Paulino, J.I. [Hospital Clinic Universitari de Valencia (Spain). Servei Traumatologia; Ferrer Albiach, C. [Hospital Clinic Universitari de Valencia (Spain). Servei Radioterapia

    1999-05-01

    A case of a 43-year-old man suffering from pleural mesothelioma with distant bone metastasis is reported. The results of bone scintigraphy and NMR findings allowed the diagnosis. The current case describes a hematogenous metastasis to the pelvis and vertebral column from a malignant pleural mesothelioma that was detected initally by bone scintigraphy. (orig.) [Deutsch] Fallbericht ueber einen 43jaehrigen Mann mit Pleural-Mesotheliom und Knochenmetastasen. Die Diagnose wurde durch Knochenszintigraphie und NMR gestellt. Der vorliegende Fall beschreibt die haematogene Metastasierung ins Becken und in die Wirbelsaeule, ausgehend von einem malignen Pleural-Mesotheliom, das urspruenglich durch Knochenszintigraphie diagnostiziert wurde. (orig.)

  13. Unusual Case of Occult Brucella Osteomyelitis in the Skull Detected by Bone Scintigraphy

    International Nuclear Information System (INIS)

    Sohn, Myung Hee; Lim, Seok Tae; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Lee, Chang Seob

    2010-01-01

    Brucellosis is a worldwide infectious disease of animals that can be transmitted to humans. Osteoarticular involvement is the most common complication of brucellosis. A 47-year-old man, who was a stock breeder, complained of myalgia with fever and chills for 2 weeks. The serology titers and blood cultures for brucellosis were positive. Bone scintigraphy demonstrated a focally increased uptake in the left supra orbital area. Plain radiographs showed an osteolytic lesion, and an MRI revealed signal abnormalities in the corresponding site. We present an unusual case of occult Brucella osteomyelitis in the frontal bone of the skull detected by done scintigraphy.

  14. Whole-body MRI in comparison to skeletal scintigraphy for detection of skeletal metastases in patients with solid tumors

    International Nuclear Information System (INIS)

    Ghanem, N.; Altehoefer, C.; Winterer, J.; Schaefer, O.; Bley, T.A.; Langer, M.; Kelly, T.; Moser, E.

    2004-01-01

    The aim of this study was to compare the diagnostic efficacy of whole-body magnetic resonance imaging (WB-MRI) as a new and rapid examination technique with skeletal scintigraphy for detection of skeletal metastases from solid tumors. In 129 patients with solid malignant tumors, WB-MRI was performed for individual comparison with skeletal scintigraphy. Examinations were performed with the innovative AngioSURF trademark rolling table with integrated phased array surface coil and coronary TIRM sequences for different body regions. The results for WB-MRI and skeletal scintigraphy were concordant in 81% of the cases, whereby both procedures excluded skeletal metastases in 43%. WB-MRI and skeletal scintigraphy demonstrated skeletal metastases in 38% of the cases, whereby WB-MRI provided more comprehensive findings in 45%. In 12% of the cases, skeletal scintigraphy was superior to WB-MRI and in 19% the findings were discordant, whereby WB-MRI detected skeletal metastases in 15 cases which had not been found on skeletal scintigraphy. In nine cases, skeletal scintigraphy was positive when the WB-MRI was negative. In 60% of the cases, WB-MRI evidenced tumor-associated findings. WB-MRI represents a promising new staging technique for detection of skeletal metastases, which is more sensitive in many cases than skeletal scintigraphy in detecting and assessing the extent of skeletal metastases - and tumor-associated findings that are relevant for treatment strategy. (orig.) [de

  15. Scintigraphy for the detection of myocardial damage in the indeterminate form of Chagas disease

    International Nuclear Information System (INIS)

    Pedroso, Enio Roberto Pietra; Rezende, Nilton Alves de

    2010-01-01

    Background: non-invasive cardiological methods have been used for the identification of myocardial damage in Chagas disease. Objective: to verify whether the rest/stress myocardial perfusion scintigraphy is able to identify early myocardial damage in the indeterminate form of Chagas disease. Methods: eighteen patients with the indeterminate form of Chagas Disease and the same number of normal controls, paired by sex and age, underwent rest/stress myocardial scintigraphy using sestamibi-99mTc, aiming at detecting early cardiac damage. Results: the results did not show perfusion or ventricular function defects in patients at the indeterminate phase of Chagas disease and in the normal controls, except for a patient who presented signs of ventricular dysfunction in the myocardial perfusion scintigraphy with electrocardiographic gating. Conclusion: the results of this study, considering the small sample size, showed that the rest/stress myocardial scintigraphy using sestamibi-99mTc is not an effective method to detect early myocardial alterations in the indeterminate form of Chagas disease (author)

  16. Scintigraphy for the detection of myocardial damage in the indeterminate form of Chagas disease

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Enio Roberto Pietra; Rezende, Nilton Alves de, E-mail: narezende@terra.com.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina; Abuhid, Ivana Moura [Instituto de Medicina Nuclear e Diagnostico Molecular, Belo Horizonte, MG (Brazil)

    2010-07-15

    Background: non-invasive cardiological methods have been used for the identification of myocardial damage in Chagas disease. Objective: to verify whether the rest/stress myocardial perfusion scintigraphy is able to identify early myocardial damage in the indeterminate form of Chagas disease. Methods: eighteen patients with the indeterminate form of Chagas Disease and the same number of normal controls, paired by sex and age, underwent rest/stress myocardial scintigraphy using sestamibi-99mTc, aiming at detecting early cardiac damage. Results: the results did not show perfusion or ventricular function defects in patients at the indeterminate phase of Chagas disease and in the normal controls, except for a patient who presented signs of ventricular dysfunction in the myocardial perfusion scintigraphy with electrocardiographic gating. Conclusion: the results of this study, considering the small sample size, showed that the rest/stress myocardial scintigraphy using sestamibi-99mTc is not an effective method to detect early myocardial alterations in the indeterminate form of Chagas disease (author)

  17. Detection of bone metastasis of prostate cancer. Comparison of whole-body MRI and bone scintigraphy

    International Nuclear Information System (INIS)

    Ketelsen, D.; Roethke, M.; Aschoff, P.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Merseburger, A.S.; Reimold, M.

    2008-01-01

    Purpose: prostate cancer continues to be the third leading cancer-related mortality of western men. Early diagnosis of bone metastasis is important for the therapy regime and for assessing the prognosis. The standard method is bone scintigraphy. Whole-body MRI proved to be more sensitive for early detection of skeletal metastasis. However, studies of homogenous tumor entities are not available. The aim of the study was to compare bone scintigraphy and whole-body MRI regarding the detection of bone metastasis of prostate cancer. Materials and methods: 14 patients with histologically confirmed prostate cancer and a bone scintigraphy as well as whole-body MRI within one month were included. The mean age was 68 years. Scintigraphy was performed using the planar whole-body technique (ventral and dorsal projections). Suspect areas were enlarged. Whole-body MRI was conducted using native T1w and STIR sequences in the coronary plane of the whole body, sagittal imaging of spine and breath-hold STIR and T1w-Flash-2D sequences of ribs and chest. Bone scintigraphy and whole-body MRI were evaluated retrospectively by experienced radiologists in a consensus reading on a lesion-based level. Results: whole-body MRI detected significantly more bone metastasis (p = 0.024). 96.4% of the demonstrated skeletal metastases in bone scintigraphy were founded in whole-body MRI while only 58.6% of the depicted metastases in MRI were able to be located in scintigraphy. There was no significant difference regarding bone metastasis greater than one centimeter (p = 0.082) in contrast to metastasis less than one centimeter (p = 0.035). Small osteoblastic metastases showed a considerably higher contrast in T1w sequences than in STIR imaging. Further advantages of whole-body MRI were additional information about extra-osseous tumor infiltration and their complications, for example stenosis of spinal canal or vertebral body fractures, found in 42.9% of patients. (orig.)

  18. sup(99m)Tc-MDP scintigraphy for the detection and localization of rhabdomyolysis

    International Nuclear Information System (INIS)

    Schicha, H.; Rumpf, K.W.; Kaiser, H.; Emrich, D.; Goettingen Univ.

    1984-01-01

    In 24 patients with biochemically proven rhabdomyolysis 34 scans with sup(99m)Tc-MDP were performed to detect regional as well as generalized myolysis. When performing the scan within 10 days after the maximum of myolysis, scintigraphic detection was possible in 95% of the patients, but after 20 days in none. Regional tracer accumulation in muscles was more frequent (89%) than generalized diffuse accumulation (31%). Predominantly muscles of the thigh, the buttocks and the upper arm were involved. Diffuse tracer accumulation in both kidneys occurred in 75% of patients with significant renal dysfunction. The results show that in addition to regional muscle damage generalized myolysis may be detected by scintigraphy with sup(99m)Tc-MDP. In cases of regional muscle damage scintigraphy proved to be more sensitive than clinical signs. (orig.) [de

  19. sup(99m)Tc-MDP scintigraphy for the detection and localization of rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Schicha, H.; Rumpf, K.W.; Kaiser, H.; Emrich, D.

    1984-12-01

    In 24 patients with biochemically proven rhabdomyolysis 34 scans with sup(99m)Tc-MDP were performed to detect regional as well as generalized myolysis. When performing the scan within 10 days after the maximum of myolysis, scintigraphic detection was possible in 95% of the patients, but after 20 days in none. Regional tracer accumulation in muscles was more frequent (89%) than generalized diffuse accumulation (31%). Predominantly muscles of the thigh, the buttocks and the upper arm were involved. Diffuse tracer accumulation in both kidneys occurred in 75% of patients with significant renal dysfunction. The results show that in addition to regional muscle damage generalized myolysis may be detected by scintigraphy with sup(99m)Tc-MDP. In cases of regional muscle damage scintigraphy proved to be more sensitive than clinical signs.

  20. Incidental Hiatal Hernia Detected with Meckel's Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Aksoy, Tamer [Afyon Kocatepe Univ. Medical Faculty, Afyon (Turkmenistan); Kiratli, Pinar Ozgen [Hacettepe Univ. Medical Faculty, Ankara (Turkmenistan)

    2011-03-15

    Congenital hiatal hernia (CHH) in children is a very rare condition that occurs in about 1 in every 2,000 to 5,000 live births, with a male to female ratio of 2:3. In 97% of cases the anomaly is unilateral with a left side preponderance. The hernia content can include the stomach, bowel loops, spleen or part of the liver. CHH may remain asymptomatic or induce only nonspecific gastro intestinal and/or thoracic symptoms. The symptomatology og these patients is usually non specific, in the form of repeated attacks of chest infection and/or recurrent vomiting, but can be associated with serious complications such as intrathoracic gastric volvulus with incarceration and strangulation. Because of the gastroesophageal reflux, linear ulcerations on the esophageal mucosa might occur and cause intermittent bleeding. Plan chest radiographs, AP and lateral, may raise a suspicion of the condition, while upper gastrointestinal contrast series are diagnostic. The treatment is surgery consisting of excision of the hernial sac after reducing the stomach and repair of the diaphragmatic defect by tightening the crura of the esophageal hiatus. If the defect is large and associated with displacement of the gastroesophageal junction (GEJ) into the thorax, adding an anti reflux procedure to the repair is appropriate. This can be achieved transabdominally either by laparotomy or laparoscopically. To the best of our knowledge, this is the second case diagnosed with Meckel's scintigraphy.

  1. Myocardial scintigraphy with gallium-67 in the detection of cardiac acute rejection

    International Nuclear Information System (INIS)

    Meneguetti, J.C.

    1990-01-01

    In order to evaluate the myocardial scintigraphy with Gallium-67 potentiality in the detection of acute rejection phenomenon, 105 studies were performed in 20 patients after they had a heart transplantation. The scintigraphic images were obtained by a conventional camera-computer system. These images were acquired 48 hours after all the patients were given an intravenous injection of 111 MBq of Gallium-67 Citrate. The biopsies were done according to the Mason technique and the histological analysis followed the Billingham standards. (author)

  2. Bone scintigraphy with 99m Tc MIBI. Its importance for the detection of malignant bone tumors

    International Nuclear Information System (INIS)

    Marrero, Luis O.; Tamayo, Alicia; Rodriguez, Oscar; Solano, Maria E.; Perera, Alejandro; Perez, Marylin

    1997-01-01

    99mT c-MIBI is a radiopharmaceutical widely employed for the detection and follow-up of different oncological diseases. The aim of the present work was to determine the value of the scintigraphy with 99mT c-MIBI for the diagnosis of malignant bone tumors, its metastases and recurrences. Twenty patients aged 24+- years old, suspected of having bone neoplasms, were studied. I

  3. Radionuclide bone scintigraphy in early detection of avascular osteonecrosis occurred in recovered SARS patients after hormone therapy

    International Nuclear Information System (INIS)

    Wang Qian; Huang Lili; Qin Shuling; Wang Yu; Nie Yuxin; Liang Tiejun; Zhang Caiqun; Zhao Yamei

    2005-01-01

    Objective: To analyze the characteristics of bone scintigraphy in patients who recovered from the severe acute respiratory syndrome (SARS), and to evaluate the clinical value of bone scintigraphy in the early diagnosis of avascular osteonecrosis (AVN) after hormone therapy. Methods: Bone scintigraphy was performed in 66 SARS patients. Among them 54 underwent MRI in bilateral hips and knees. Both images were compared and followed up clinically. Results: Abnormal scintigraphy was found in 30 (45.5%) of the 66 recovered SARS patients. Total 82 foci were found in hip, knee, ankle, elbow, shoulder, wrist and the middle of the tibia. Hip and knee joints were the most involved sites. 25 patients with 71 lesions were symptomatic, whereas 11 in 5 patients were asymptomatic, lesions in 8 patients were multifocal. The lesions found in scintigraphy and MRI were concordant in 92.6% of the joints. But more lesions could be detected by bone scintigraphy. Conclusions: SARS patients have a high occurrence of AVN, usually involved in multiple sites. Bone scintigraphy should be the first choice method used for early detection of AVN. (authors)

  4. Sensitivity of scintigraphy with 111In-lymphocytes for detection of cardiac allograft rejection

    International Nuclear Information System (INIS)

    Eisenberg, S.B.; Eisen, H.J.; Sobel, B.E.; Bergmann, S.R.; Bolman, R.M. III

    1988-01-01

    We recently demonstrated the feasibility of noninvasive detection of cardiac allograft rejection after administration of indium-111-labeled lymphocytes. To determine the sensitivity and specificity of the technique, as well as its value for delineating the severity of rejection, we studied 16 dogs with heterotopic thoracic cardiac allografts. Five animals were evaluated while exposed to immunosuppressive agents. Animals were scanned sequentially after administration of 100-400 microCi of indium-111-labeled autologous lymphocytes. Myocardial lymphocyte infiltration was expressed as the indium excess (IE), defined as the ratio of indium activity of the transplant or native heart compared with that in blood. Scintigraphic results were compared with characteristics of simultaneously obtained endomyocardial biopsies. Among 17 biopsy documented episodes of rejection, 16 were detected scintigraphically. Among 18 biopsies with no evidence of rejection, scintigraphy was uniformly negative. Thus, the sensitivity and specificity of scintigraphy were 94 and 100%, respectively. Biopsies graded as showing no rejection were associated with an IE of 0.3 +/- 0.5 (+/- SD); those graded as mild, 2.8 +/- 1.7; those as moderate, 10.7 +/- 7.2; and those graded as indicative of severe rejection, 14.2 +/- 4.5. Thus, scintigraphy with indium-111-labeled lymphocytes sensitively and specifically detects cardiac allograft rejection and delineates the intensity of the rejection process. It should be useful clinically for assessing potential allograft rejection noninvasively

  5. Clinical experience of [sup 123]I-IMP scintigraphy in detecting vertebral bone metastases of hepatocellular carcinoma. A comparison with bone scintigraphy with [sup 99m]Tc-MDP

    Energy Technology Data Exchange (ETDEWEB)

    Suto, Y. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Iwamiya, T. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Tanigawa, N. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Shabana, M. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Ohta, Y. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan))

    1994-03-01

    [sup 123]I-IMP and bone scintigraphy with [sup 99m]Tc-MDP were consecutively performed in patients with vertebral bone metastases from hepatocellular carcinoma and lumbar spondylosis deformans in a 7-day interval or shorter. The intensity of uptake was compared. Eighteen of the 20 metastatic lesions (90%) were classified as increased uptake areas in [sup 123]I-IMP scintigraphy. MDP-scintigraphy disclosed 16 metastatic lesions (80%), 9 as ''hot'' lesions (56%) and 7 as ''cold'' lesions (44%). [sup 123]I-IMP scintigraphy was negative in all 12 lesions of lumbar spondylosis deformans. Compared to MDP-scintigraphy, [sup 123]I-IMP scintigraphy was more sensitive in detecting vertebral bone metastases of hepatocellular carcinoma with smaller rates of false-positive and false-negative findings. (orig./MG).

  6. In-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Hanano, Masaharu; Kimura, Michio; Ojima, Kenji [Niigata Univ. (Japan). School of Medicine

    1984-06-01

    /sup 111/In-labeled platelet scintigraphy was carried out in 20 patients suspected of thrombosis, to evaluate its efficacy for the detection of intracardiac and intravascular thrombi. Hemostatic studies including PT, aPTT, fibrinogen, FDP, platelet retention by Hellem II method, platelet aggregation induced by ADP (1 ..mu..M, 10 ..mu..M), collagen (2 ..mu..g/ml) and arachidonate (2 mM), and platelet survival were examined simultaneously. Two of these patients were also studied by fibrinogen scintigraphy labeled with sup(99m)Tc. The platelets obtained from the patients were labeled with /sup 111/In-oxine according to a method originated by Yui et al. In the platelet scintigram, positive findings were demonstrated in 9 cases : 2 left ventricular, 3 left atrial, and 4 vascular thrombi. These were in a good accordance to the findings obtained by at least one from angiography, echography and surgery. Platelet aggregation induced by 1 ..mu..M ADP was elevated in 4 of the 7 patients with positive findings and 3 of the 7 patients with negative findings. Shortened platelet survivals were observed in two of the 10 patients; dissecting aortic aneurysm and infective prosthetic valve endocarditis with hepatosplenomegaly. There was no significant difference in the platelet function and the platelet survival between the patients with positive and negative findings. It was difficult to detect thrombi by the fibrinogen scintigraphy labeled with sup(99m)Tc in the two patients studied. In conclusion, /sup 111/In-labeled platelet scintigraphy seems to be very useful to detect thrombi.

  7. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi

    1994-01-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of 99m Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, γ-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author)

  8. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1994-06-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of [sup 99m]Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, [gamma]-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author).

  9. Evaluation of quantitative sacroiliac scintigraphy for the early detection of sacroiliitis

    International Nuclear Information System (INIS)

    Prakash, S.; Malaviya, A.N.; Gopinath, P.G.; Bhargava, S.; Mehra, N.K.

    1983-01-01

    Quantitative sacroliac scintigraphy (QSS) was evaluated for the detection of sacroiliac (SI) joint disease before the appearance of radiographic/changes. QSS with fractional quantitation was done in 13 age- and sexmatched controls and 28 patients with different grades of radiographic sacroliitis. The SI index of each joint was considered separately. The mean SI index values in patients with grade I radiographic sacroiliitis (1.54) and HLA-B27 positive patients with low back pain (1.50) were significantly (P 0.05). Thus a large overlap between the normal and abnormal ranges of sacroiliac ratios limits the utility of quantitative sacroiliac scintigraphy for the early diagnosis of sacroiliac joint disease. (orig.)

  10. Early detection of interstitial pneumonia by 67Ga-citrate scintigraphy

    International Nuclear Information System (INIS)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada

    1985-01-01

    In this paper we report our recent experience indicating usefulness of 67 Ga-citrate scintigraphy in 4 cases with inflammatory pulmonary diseases. These cases showed abnormal pulmonary 67 Ga uptake with normal chest radiographs. The first case with malignant lymphoma and the second one with lung cancer suffered from pulmonary infection following secondary immuno-insufficiency due to radiotherapy and chemotherapy. Pneumocystis carinii was suspected as causative agent in the first case, and gram negative bacilli in the second case. The third case with lung cancer developed radiation pneumonia after radiotherapy. The fourth case with acute bronchitis developed drug induced interstitial pneumonia presumably due to minocycline administration. It is concluded that 67 Ga-citrate scintigraphy is more sensitive for early detection of interstitial pneumonia than routine chest radiography. (author)

  11. Salivary scintigraphy

    International Nuclear Information System (INIS)

    Sabri, P.J.

    1988-01-01

    Salivary gland scintigraphy with technetium 99m ( 99m Tc) in the form pertechnetate ion is a relatively simple procedure, which can provide a unique and sensitive means for investigating salivary gland physiologic function and its derangements. However, salivary scintigraphy is poorly suited for the detection and characterization of masses in and around the salivary glands. Computed tomography (CT) has, therefore, largely supplanted scintigraphy for the evaluation of masses and is the method of choice because it can provide exquisite anatomic detail. Consequently, CT is more sensitive for mass detection and can also provide useful information as to whether a mass has arisen from within or from outside of a salivary gland or whether a mass is circumscribed or invasive. It also can disclose the relationship of the mass to the facial nerve and occasionally can provide histologic characterization of such masses as cysts, lipomas, and masseter muscle hypertrophy

  12. Diagnostic advantages of the association of electrocardiograms and thallium 201 exercise scintigraphy in detecting coronary disease

    International Nuclear Information System (INIS)

    Tubau, J.F.; Chaitman, B.R.; Dupras, G.; Waters, D.D.; Bourassa, M.G.

    1979-01-01

    Thallium 201 exercise scintigraphy combined with 14-lead exercise electrocardiography detects coronary artery disease in 95-96 percent of the patients, whether men or women. When both tests were positive, 93 percent of the men and 100 percent of the women had coronary artery disease. In women, thallium 201 seems to do better than 14-lead exercise electrocardiogram, detecting the presence of coronary artery disease in 72 percent and its absence in 83 percent of the cases. In approximately 50 percent of the cases, the results of thallium 201 and multiple-lead exercise testing were discordant; in these cases, an accurate clinical history is helpful. (author) [fr

  13. Comparison of somatostatin analogue and metaiodobenzylguanidine scintigraphy for the detection of carcinoid tumours

    International Nuclear Information System (INIS)

    Nocaudie-Calzada, M.; Huglo, D.; Carnaille, B.; Proye, C.; Marchandise, X.

    1996-01-01

    The purpose of this prospective study was to compare the ability of radiolabelled somatostatin analogue (RSA) and metaiodobenzylguanidine (MIBG) scintigraphy to display carcinoid tumours. Forty patients were studied after radiological assessment based on clinical symptomatology. These patients had radiologically demonstrated tumours (n=28), resected tumours discovered to be of the carcinoid type (n=5) or clinically and biologically suspected carcinoid tumours (n=7). They underwent indium-111 DTPA-pentetreotide or iodine-123-Tyr-3-octreotide and 131 I-MIBG scintigraphy. The results were compared with those of complementary surgical or morphological examinations and analysed according to the site of the tumour and the symptomatology. In the case of 31 patients with a total of 55 tumoral sites, the sensitivity of the initial radiological assessment, of RSA and of MIBG was 96%, 86% and 64%, respectively, for the detection of at least one tumour per patient, but 51%, 85% and 51%, respectively, for the total number of sites. No site was detected solely by MIBG. The concordance between RSA and MIBG was better when all sites were considered (kappa index+0.44) than for only extrahepatic abdominal tumoral sites (kappa index+0.095). Abdominal, thoracic or bone marrow tumours were more easily detected with RSA than with MIBG. Hepatic invasion (21 cases) was more easily detected by radiology (sensitivity 100%) than by RSA and MIBG, both of which displayed a sensitivity of 80%, but with differences in uptake intensity. Tumour detection using MIBG was more significantly linked with flush (P 0.10). In the assessment of carcinoid tumours, RSA scintigraphy should be carried out initially (just after hepatic ultrasonography) and supplemented by MIBG, as comparison of the studies serves to guide therapeutic options and might be valuable for prognosis. (orig.). With 2 figs., 3 tabs

  14. Comparison of FDG-PET/CT and bone scintigraphy for detection of bone metastases in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Steffen; Heusner, Till; Forsting, Michael; Antoch, Gerald (Dept. of Diagnostic and Interventional Radiology and Neuroradiology, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany)), email: steffen.hahn@uk-essen.de; Kuemmel, Sherko; Koeninger, Angelika (Dept. of Gynecology and Obstetrics, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany)); Nagarajah, James; Mueller, Stefan; Boy, Christian; Bockisch, Andreas; Stahl, Alexander (Dept. of Nuclear Medicine, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany))

    2011-11-15

    Background Bone scintigraphy is the standard procedure for the detection of bone metastases in breast cancer patients. FDG-PET/CT has been reported to be a sensitive tool for tumor staging in different malignant diseases. However, its accuracy for the detection of bone metastases has not been compared to bone scintigraphy. Purpose To compare whole-body FDG-PET/CT and bone scintigraphy for the detection of bone metastases on a lesion basis in breast cancer patients. Material and Methods Twenty-nine consecutive women (mean age 58 years, range 35-78 years) with histologically proven breast cancer were assessed with bone scintigraphy and whole-body FDG-PET/CT. Twenty-one patients (72%) were suffering from primary breast cancer and eight patients (28%) were in aftercare with a history of advanced breast cancer. Both imaging procedures were assessed for bone metastases by a radiologist and a nuclear medicine physician. Concordant readings between bone scintigraphy and FDG-PET/CT were taken as true. Discordant readings were verified with additional MRI imaging in all patients and follow-up studies in most patients. Results A total of 132 lesions were detected on bone scintigraphy, FDG-PET/CT or both. According to the reference standard, 70/132 lesions (53%) were bone metastases, 59/132 lesions (45%) were benign, and three lesions (2%) remained unclear. The sensitivity of bone scintigraphy was 76% (53/70) compared to 96% (67/70) for FDG-PET/CT. The specificity of bone scintigraphy and FDG-PET/CT was 95% (56/59) and 92% (54/59), respectively. According to the reference standard bone metastases were present in eight out of the 29 patients (28%), whereas 20 patients (69%) were free of bone metastases. One (3%) patient had inconclusive readings on both modalities as well as on MRI and follow-up studies. Bone scintigraphy and FDG-PET/CT correctly identified seven out of eight patients with bone metastases and 20 out of 20 patients free of metastases. Conclusion On a lesion

  15. Detection of mediastinitis after heart transplantation by gallium-67 scintigraphy

    International Nuclear Information System (INIS)

    Quirce, R.; Serano, J.; Arnal, C.; Banzo, I.; Carril, J.M.

    1991-01-01

    We report the findings of a patient with post-cardiac transplant mediastinitis detected by 67 Ga-citrate imaging. Fever and leukocytosis were the first clinical signs suggesting infection. The usual diagnostic modalities, including CT and ultrasound, failed to identify the site of infection. A 67 Ga scan showed intense abnormal uptake behind the sternum. The site of uptake was shown by necropsy to be necrotic tissue involving cardiac sutures, pulmonary arteries, and the aorta due to infection with Haemophilus aphrophilus

  16. Usefulness of Technetium 99 m- Sestamibi (MIBI) scintigraphy in the detection of parathyroid adenoma and hyperplasia

    International Nuclear Information System (INIS)

    Markarian, Maria F.; Yelin, Enrique G.; Aparicio, Rocio; Marino, Juan M.

    2005-01-01

    Purpose: To evaluate parathyroid substration scintigraphy with Tc99m-pertechnetate-Tc99m-MIBI, for detection of parathyroid adenomas or hyperplasia in patients with hyperparathyroidism. Materials and methods: Thirty patients were studied by Tc99m-pertechnetate-Tc99m-MIBI scintigraphy, 24 with primary hyperparathyroidism, 2 with hypo echogenic nodular image behind the thyroid gland, 1 with bone fracture history, 1 with hypophosphataemia and 2 with secondary hyperparathyroidism. The initial image was made with pertechnetate, the next one and the late (2-3 hs) with Tc99m-MIBI, making digital substration with the first image. Six patients were excluded (difficult follow-up n=5, death n=1). Results: The final 24 patients series showed: 10 positive and 12 negative for adenomas; 1 positive and 1 negative for hyperplasia. The correlation between the scintigraphic study and the clinical, biochemical and anatomicopathological data, showed a high sensitivity (90%), and specificity (92%), for parathyroid adenomas and/or hyperplasia. Conclusions: The Tc99m-pertechnetate-Tc99m-MIBI shows high sensitivity and high specificity for the detection of adenomas and hyperplasia in patient with hyperparathyroidism. (author)

  17. Radionuclide scintigraphy in detection of gastroesophageal reflux in survivors of congenital diaphragmatic hernia

    International Nuclear Information System (INIS)

    Thomas, E.J.; Bharathi Dasan, J.; Patel, C.D.; Bal, C.S.; Malhotra, A.; Kumar, R.; Mitra, D.K.; Agarwala, S.; Padhy, A.K.

    2003-01-01

    Gastro-esophageal Reflux is a common cause of long-term morbidity in survivors of congenital diaphragmatic hernia. The present retrospective analysis was undertaken to find out the incidence of GER in survivors of congenital diaphragmatic hernia (CDH). A total of 26 survivors of congenital diaphragmatic hernia with a mean age of 19 months were studied. Of these, only 7 had clinical symptoms suggestive of GER such as recurrent respiratory tract infection, vomiting, regurgitation, and epigastric pain. The remaining 19 were asymptomatic and had radionuclide scintigraphy for detection of GER as a part of routine follow-up. All the 26 underwent radionuclide scintigraphy with 100-200 μCi (3.7 -7.4MBq) of Tc99m-Sulphur Colloid. GER was detected in 11 out of 26 patients (4 out of 7 symptomatic patients and 7 out of 19 asymptomatic patients). We concluded that there is high incidence of GER in survivors of congenital diaphragmatic hernia and these patients should be followed up for GER regularly. Scintiscanning being a simple, noninvasive test, may be used for initial evaluation and follow-up of survivors of CDH for GER. (author)

  18. Evaluation of breast MIBI-Tc 99 m scintigraphy for the detection of breast cancer

    International Nuclear Information System (INIS)

    Loriaux, C.; Baeyens, L.; Paternot, J.; Martin, P.; Verhas, M.

    1997-01-01

    Full text. The aim of the work was to appreciate the contribution of MIBI-Tc 99 m scintigraphy for the detection of breast cancer and to situate this procedure in comparison with mammography 5 (X-ray M) and echography (E C). 21 patients presenting suspected lesion on clinical evaluation/or mammography were referred to the department for breast MIBI-Tc 99 m scintigraphy. 10 min after IV injection of MIBI-Tc 99 m 3 planar scan were realized with a present time of 10 min. The whole investigation including X-ray and surgical procedures were performed within 15 days. The pathologic findings were: 21 malignant lesion (18 canal cancers, 3 lobular cancers), 4 benign lesions (1 fibroadenoma, 2 granuloma, 1 fibrocystic disease). Lesions were bilateral in 3 cases and there was 1 bifocal lesion. 17 tumours were palpable and 8 not palpable, 10 lesion were 2,5 cm (24%). The overall sensitivity and specificity for MIBI-Tc 99 m were 67% and 75% respectively. For the group of palpable tumours, sensitivity of MIBI-Tc 99 m was 86%. In three cases, the X-ray M was difficult to interpret, the MIBI-Tc 99 m was true positive. In 3 false positive X-ray M procedures, the scintigraphy was true negative but, whatever the size of the tumor the best sensitivity was obtained with X-ray M (71%) and E C (70%) while for MIBI Tc-99 m, sensitivity was less (67%). MIBI-Tc 99 m appears to be a complementary tool in cases of difficulty of interpretation of mammography particularly in case of recurrence of the disease

  19. Evaluation of breast MIBI-Tc 99 m scintigraphy for the detection of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Loriaux, C.; Baeyens, L.; Paternot, J.; Martin, P.; Verhas, M. [Hospital Universitaire Brugmann, Bruxelles (Belgium). Service de Medecine Nucleaire et Clinique de Senologie

    1997-12-31

    Full text. The aim of the work was to appreciate the contribution of MIBI-Tc 99 m scintigraphy for the detection of breast cancer and to situate this procedure in comparison with mammography 5 (X-ray M) and echography (E C). 21 patients presenting suspected lesion on clinical evaluation/or mammography were referred to the department for breast MIBI-Tc 99 m scintigraphy. 10 min after IV injection of MIBI-Tc 99 m 3 planar scan were realized with a present time of 10 min. The whole investigation including X-ray and surgical procedures were performed within 15 days. The pathologic findings were: 21 malignant lesion (18 canal cancers, 3 lobular cancers), 4 benign lesions (1 fibroadenoma, 2 granuloma, 1 fibrocystic disease). Lesions were bilateral in 3 cases and there was 1 bifocal lesion. 17 tumours were palpable and 8 not palpable, 10 lesion were <1 cm (40%), 9 were between 1,1 and 2,5 cm (36%) and 7 were >2,5 cm (24%). The overall sensitivity and specificity for MIBI-Tc 99 m were 67% and 75% respectively. For the group of palpable tumours, sensitivity of MIBI-Tc 99 m was 86%. In three cases, the X-ray M was difficult to interpret, the MIBI-Tc 99 m was true positive. In 3 false positive X-ray M procedures, the scintigraphy was true negative but, whatever the size of the tumor the best sensitivity was obtained with X-ray M (71%) and E C (70%) while for MIBI Tc-99 m, sensitivity was less (67%). MIBI-Tc 99 m appears to be a complementary tool in cases of difficulty of interpretation of mammography particularly in case of recurrence of the disease

  20. Detection of acute gastrointestinal bleeding by intra-arterial scintigraphy: an experimental study and preliminary clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Joo Hyeong; Kim, Duk Yoon; Yi, Bum Ha; Lee, Dong Ho; Yoon, Yup [Kyunghee Univ. College of Medicine, Seoul (Korea, Republic of); Song, Mi Jin [Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    The purpose of this animal and clinical study was to compare intra-arterial (IA) scintigraphy with angiography in the localization of gastrointestinal (GI) bleeding. After sedation with intramuscularly administered ketamine, lower GI bleeding was induced in ten rabbits. Using inguinal cut-down, an arterial femoral 3F catheter was placed in the proximal mesenteric artery. Following abdominal incision to expose the bowel, lower GI bleeding was caused by incising the antimesenteric border of the small bowel wall. Initial angiography was performed, and this was followede by Tc-99m pertechnetate IA scintigarphy. Tc-99m RBC IA scintigraphy involved two patients who had undergone selective mesenteric arterial catheterizaion for the evaluation of acute lower GI bleeding. Ten rabbits, bleeding at a mean rate of 0.7g/min, were studied. IA scintigraphy was superior to angiography in four cases and equal in six. The sensitivity of angiography was 40%(4/10), and IA scintigraphy 80%(8/10). In one patient, Tc-99m RBC was administered directly into the superior mesenteric artery and ulcer bleeding in the transverse colon was identified. PRior to conventional angiography, the bleeding had been occult. In a second patient, in whom angiography had revealed a hypervascular mass, selective injection of Tc-99m RBC into the superior mesenteric artery revealed tumor(leiomyoma) bleeding in the jejunum. Selective IA scintigraphy was valuable for detecting intestinal bleeding, occult during conventional studies and may be useful for detecting acute bleeding at the time of negative angiography.=20.

  1. Hepatic changes caused by exposure to telecobalt rays as detected by scintigraphy and computed tomography

    International Nuclear Information System (INIS)

    Lueth, I.

    1987-01-01

    Hepatic scintiscans obtained in a cohort of 111 patients subjected to partial irradiation of the liver using telecobalt showed low density spots for 53 of those individuals. Comparative assessments in a control group proved the liver's accumulation behaviour to be totally unrelated to factors like age, sex and dose administered. The liver is only to a very limited extent capable of recovering from radiation damage that is severe enough to be detected by scintigraphy or computed tomography. In the group examined here, spontaneous recovery was seen in no more than 7.5% of cases. Long-term plotting of the hepatic radioactivity levels seen in scintigrammes showed these to be reduced for periods of up to nine years. Such pathological changes were already observed at radiation levels as low as 12 Gy, even though a definite dose-dependency of defective accumulation, as shown by scintigraphy or computed tomography, could not be established. Particular mention should here be made of the fact that the losses of activity seen in hepatic scintiscans were not necessarily confirmed by pathological findings revealed at the same time on the basis of computed tomography. Liver function tests in the serum permitted no links to be established between the occurrence of low density spots in the scintiscans or tomograms and typical enzyme patterns that may be interpreted as being suggestive of radiation injury. (orig.) [de

  2. Detection of axillary lymph node metastases in breast carcinoma by technetium-99m sestamibi breast scintigraphy, ultrasound and conventional mammography

    International Nuclear Information System (INIS)

    Lam, W.W.M.; Yang, W.T.; Chan, Y.L.; Stewart, I.E.T.; Metreweli, C.; King, W.

    1996-01-01

    Axillary lymph node status is important in the staging of breast carcinoma. To evaluate the accuracy of technetium-99m sestamibi breast scintigraphy in detecting metastatic axillary lymph nodes as compared with other accepted imaging modalities, we performed 99m Tc-sestamibi breast scintigraphy, conventional mammography and ultrasound in 36 patients with primary untreated breast cardinoma. With histopathology as the gold standard, 99m Tc-sestamibi breast scintigraphy was found to yield true-positive results in 7 of 11 cases (64%) of axillary lymph nodes metastases and true-negative results in 18 of 20 cases (90%); it has an accuracy of 81%, a positive predictive value of 77.8% and a negative predicive value of 81.8%. (orig.)

  3. Can Stress Echocardiography Compete with Perfusion Scintigraphy in the Detection of Coronary Artery Disease and Cardiac Risk Assessment?

    NARCIS (Netherlands)

    M.L. Geleijnse (Marcel); A. Elhendy (Abdou)

    2000-01-01

    textabstractAims: The aim of this review was to define the place of stress echocardiography in the context of perfusion scintigraphy for the detection of coronary artery disease (CAD) and the assessment of cardiac risk. Stress echocardiography has the benefits of widespread availability, relatively

  4. Myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Hisada, Kinichi

    1982-01-01

    Among the various methods of image diagnosis of the cardiovascular disorder, nuclear cardiology provides noninvasive means for evaluation of myocardial perfusion as well as morphological and functional informations. In this article, clinical application and image diagnosis of myocardial scintigraphy including Tl-201 myocardial perfusion scintigraphy, single photon emission computed tomography with Tl-201, acute myocardial infarction scintigraphy with Tc-99m-pyrophosphate and Ga-67 imaging of the heart, were discussed. Multiplanar imaging of the heart with Tl-201 after stress and at redistribution was the accepted method for detection and evaluation of the ischemic heart disease. Although it achieved high sensitivity and specificity for ischemic heart disease, detection of the small ischemia and quantation of the regional Tl-201 accumulation were difficult with conventional multiplanar imaging. Application of emission computed tomography improved detectability and quantitativity of the ischemia. However, 7-pinhole tomography did not increase the diagnostic accuracy significantly. It had limited clinical applicability due to poor quantitativity in spite of improved image contrast and its tomographic nature. Advantage and limitation of these tomographic imaging and multiplanar imaging were discussed. Problems and prognostic significance of pyrophosphate imaging of the acute myocardial infarction were also discussed. Visualization of the heart with Ga-67 was helpful for identification of the tumor or inflammation of the heart as well as evaluation of the effect of the therapy. (author)

  5. Detection of rejection of canine orthotopic cardiac allografts with indium-111 lymphocytes and gamma scintigraphy

    International Nuclear Information System (INIS)

    Eisen, H.J.; Rosenbloom, M.; Laschinger, J.C.; Saffitz, J.E.; Cox, J.L.; Sobel, B.E.; Bolman, R.M. III; Bergmann, S.R.

    1988-01-01

    Previous studies have demonstrated the feasibility of detecting canine heterotopic cardiac allograft rejection scintigraphically after administration of 111In lymphocytes. To determine whether the approach is capable of detecting rejection in orthotopic cardiac transplants in which labeled lymphocytes circulating in the blood pool may reduce sensitivity, the present study was performed in which canine orthotopic cardiac transplants were evaluated in vivo. Immunosuppression was maintained with cyclosporine A (10-20 mg/kg/day) and prednisone (1 mg/kg/day) for 2 wk after transplantation. Subsequently, therapy was tapered. Five successful allografts were evaluated scintigraphically every 3 days after administration of 100-350 microCi 111In autologous lymphocytes. Correction for labeled lymphocytes circulating in the blood pool, but not actively sequestered in the allografts was accomplished by administering 3-6 mCi 99mTc autologous erythrocytes and employing a previously validated blood-pool activity correction technique. Cardiac infiltration of labeled lymphocytes was quantified as percent indium excess (%IE), scintigraphically detectable 111In in the transplant compared with that in blood, and results were compared with those of concomitantly performed endomyocardial biopsy. Scintigraphic %IE for hearts not undergoing rejection manifest histologically was 0.7 +/- 0.4. Percent IE for rejecting hearts was 6.8 +/- 4.0 (p less than 0.05). Scintigraphy detected each episode of rejection detected by biopsy. Scintigraphic criteria for rejection (%IE greater than 2 s.d. above normal) were not manifest in any study in which biopsies did not show rejection. Since scintigraphic results with 111In-labeled lymphocytes were concordant with biopsy results in orthotopic cardiac transplants, noninvasive detection of graft rejection in patients should be attainable with the approach developed

  6. Tc-99m-DTPA renal scintigraphy and detection of intrarenal reflux

    International Nuclear Information System (INIS)

    Poropat, M.; Basic, M.; Dodig, D.; Batinic, D.; Nizic, Lj.

    1994-01-01

    The intrarenal reflux plays the key role in the etiology of reflux nephropathy and its detection is of utmost importance in evaluating possible damage in kidney with reflux. In 176 kidneys (113 children) with different degree of vesicoureteric reflux (VUR), dynamic renal scintigraphy with Tc-99m-DTPA in zoom mode was performed. From each study 6 functional images of mean time were generated, kidney contour superimposed on each, and time activity curves (TAC) over possible areas of increased mean time were generated. In these study we analyzed only areas of increased mean time over the outer contour of the kidney which corresponds to the renal parenchyma. In later functional images of the mean time we found 53 focal retentions over the part of the kidney which corresponds to the renal cortex (33 in upper, 5 in middle and 15 in lower part of the kidney). TAC-s generated over these areas exhibited a sharp increase of activity on the descending part of the curves. We propose that the return of activity from the collecting system to the kidney cortex represents intrarenal reflux. In our opinion, analysis of functional images of the mean time could be a method for more accurate detection of intrarenal reflux and indicating the children with high risk to acquire renal scarring. (author)

  7. Indium-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Michio; Ojima, Kenji; Tsuda, Takashi [Niigata Univ. (Japan). School of Medicine

    1983-09-01

    This study was designed to evaluate the efficacy of scintigraphy by using /sup 111/In-oxine labeled platelets for the detection of either intracardiac or intravascular thrombi. Fourteen cases of thrombi diagnosed or suspected on the basis of either angiography or two-dimensional echography were examined. They included four cases of left ventricular thrombi, three of left atrial thrombi, four of vascular thrombi and three of inflammatory disease. Platelet samples from the patients were labeled by /sup 111/In-oxine according to the method originated by Yui et al. The labeling efficiency was 72.4+-9.8%. The platelets retained good function except for collagen aggregability. Hot areas of high quality in the scintigram were demonstrated in six cases including two with left ventricular thrombi, two with left atrial thrombi and two with vascular thrombi. These areas accorded well with the findings of angiography, echography or surgery. The removed thrombi had a layer of aggregated platelets on the surface. Platelet survival was shortened in a case of prosthetic valve endocarditis without a hot area, and was normal in four out of the five cases including two with a hot area. It is concluded that this method is potentially predictive in detecting thrombi.

  8. Somatostatin receptor scintigraphy and intraoperative gamma probe detection in the localisation and treatment of pancreatic insulinoma

    International Nuclear Information System (INIS)

    Loh, Nelson K.; Macdonald, William B.; Dunne, Marina L.; Rao, Sudhakar

    2009-01-01

    Full text: Aims: We report a case of insulinoma that was successfully enucleated under radio-guidance after an initial unsuccessful laparotomy. This case highlights the utility of Somatostatin Receptor Scintigraphy (SRS) and gamma probe in the localisation and treatment of neuroendocrine tumours. Methods: The patient presented with recurrent hypoglycaemia. An abdominal CT scan identified a lesion in the uncinate process of the pancreas, however, laparotomy with use of intraoperative ultrasound failed to localise the lesion. SRS with SPECTICT was then requested by the surgical team with a view to radio-guided surgery. Results: SRS demonstrated an octreotide-avid tumour in the posterior uncinate process of the pancreas, and confirmed suitability for radio-guided surgery. At re-exploration, the surgeon was again unable to palpate the lesion or localise it with intraoperative ultrasound, however, the lesion was successfully detected and removed with the use of a gamma probe. A postoperative SRS confirmed complete excision and histopathology was diagnostic of insulinoma. Conclusion: This case highlights the utility of SRS in the intraoperative localisation and surgical excision of neuroendocrine tumours. The lesion was unable to be localised clinically or with intraoperative ultrasound but was successfully detected with scintigraphic techniques. The surgical team acknowledge that the use of a gamma probe enabled enucleation of the insulinoma, which obviated the need for an invasive Whipple's procedure.

  9. Diagnostic performance of [18F] FDG PET-CT compared to bone scintigraphy for the detection of bone metastases in lung cancer patients

    International Nuclear Information System (INIS)

    RODRIGUES, Margarida; STARK, Hannes; RENDL, Gundula; RETTENBACHER, Lukas; PIRICH, Christian; DATZ, Lidwina; STUDNICKA, Michael

    2016-01-01

    Accurate staging of lung cancer is essential for effective patient management and selection of appropriate therapeutic strategy. The aim of this paper was to compare the value of bone scintigraphy and FDG PET-CT for detecting bone metastases in lung cancer patients and the impact of these modalities in disease staging. One hundred sixty-four lung cancer patients who had undergone both FDG PET-CT and bone scintigraphy within 14 days were included into this study. The analysis of FDG PET-CT and bone scintigraphy was carried out patient- and lesion-based. One hundred twenty-one patients were negative and 43 patients positive for bone metastases. FDG PET-CT found bone metastases in 42/43 patients and bone scintigraphy in 38/43 patients. Sensitivity, specificity and accuracy of FDG PET-CT and bone scintigraphy for detecting bone metastases were 97.7%, 100% and 99.4%, and 87.8%, 97.5% and 94.2%, respectively. FDG PET-CT identified 430 bone metastases and bone scintigraphy 246 bone metastases. Skull was the only region where bone scintigraphy identified more lesions than FDG PET-CT. Based on both scintigraphic modalities disagreement concerning disease stage was found in 3 patients. In conclusion, FDG PET-CT yielded a higher sensitivity, specificity and accuracy than bone scintigraphy for identifying bone metastases in lung cancer patients. FDG PET-CT thus can be recommended for initial staging of lung cancer patients without applying bone scintigraphy for the detection of bone metastases.

  10. Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution Thallium scintigraphy

    NARCIS (Netherlands)

    W. Wijns (William); P.W.J.C. Serruys (Patrick); J.H.C. Reiber (Johan); P.J. de Feyter (Pim); M.J.B.M. van den Brand (Marcel); M.L. Simoons (Maarten); P.G. Hugenholtz (Paul)

    1985-01-01

    textabstractThe value of exercise testing and thallium scintigraphy in predicting recurrence of angina pectoris and restenosis after a primary successful transluminal coronary angioplasty (PTCA) was prospectively evaluated. In 89 patients, a symptom-limited exercise electrocardiogram (ECG) and

  11. Deep venous thrombophlebitis: detection with 4-hour versus 24-hour platelet scintigraphy

    International Nuclear Information System (INIS)

    Seabold, J.E.; Conrad, G.R.; Ponto, J.A.; Kimball, D.A.; Frey, E.E.; Ahmed, F.; Coughlan, J.D.; Jensen, K.C.

    1987-01-01

    Thirty-one nonheparinized patients with suspected deep venous thrombophlebitis (DVT) underwent contrast venography and indium-111 platelet scintigraphy (In-111 PS). Venography permitted identification of acute DVT in 12 of 31 cases (39%). One additional patient was considered to have acute DVT despite nonconclusive venography results. In-111 PS results were positive at 4 hours in nine of 13 cases (69%) and at 24 hours in 12 of 13 cases (92%). Two of four patients with false-negative 4-hour In-111 PS studies had received warfarin. Thus, the sensitivity of 4-hour In-111 PS in patients not receiving anticoagulants was 82%. Venography results were negative for acute DVT in 18 cases, and 4-hour In-111 PS studies were negative or equivocal in each. In-111 PS is an alternative to contrast venography for detecting acute DVT. If 4-hour In-111 PS results are positive, anticoagulation can be initiated. Delayed images are necessary if the 4-hour images are negative or equivocal

  12. Early detection of interstitial pneumonia by WXGa-citrate scintigraphy. Cases of abnormal pulmonary WXGa uptake with normal chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada

    1985-04-01

    In this paper we report our recent experience indicating usefulness of WXGa-citrate scintigraphy in 4 cases with inflammatory pulmonary diseases. These cases showed abnormal pulmonary WXGa uptake with normal chest radiographs. The first case with malignant lymphoma and the second one with lung cancer suffered from pulmonary infection following secondary immuno-insufficiency due to radiotherapy and chemotherapy. Pneumocystis carinii was suspected as causative agent in the first case, and gram negative bacilli in the second case. The third case with lung cancer developed radiation pneumonia after radiotherapy. The fourth case with acute bronchitis developed drug induced interstitial pneumonia presumably due to minocycline administration. It is concluded that WXGa-citrate scintigraphy is more sensitive for early detection of interstitial pneumonia than routine chest radiography.

  13. High sensitivity of the in vivo detection of somatostatin receptors by 111Indium (DTPA-Octreotide)-scintigraphy in meningioma patients

    International Nuclear Information System (INIS)

    Hildebrandt, G.; Luyken, C.; Klug, N.; Scheidhauer, K.; Schicha, H.; Dahms, P.; Krisch, B.

    1994-01-01

    The recent availability of isotope-labelled somatostatin analogues has allowed one to detect somatostatin receptors in normal tissue as well as in endocrine or non-endocrine cranial tumours. The purpose of the present study was to establish the value of somatostatin receptor scintigraphy using an 111 indium-labelled somatostatin analogue, octreotide, in the diagnostic work-up of meningioma patients. Twenty-two patients (16 women, 6 men, aged from 19-70 years) with newly diagnosed, residual or recurrent cranial meningiomas were examined. 111 indium-labelled DTPA-octreotide was injected i.v.. Planar and tomographic images were obtained with a gamma camera 4-6, and 24 hours after injection. In all of the meningiomas studies a high density of somatostatin receptor was detected by scintigraphy. No false negative test result was found. Due to this, a 100% predictive value of a negative test was calculated. However, when the tumours were taken in culture differing staining intensity could be seen in the light- and electron microscopic level even on individual cells of a single culture when silver intensified somatostatin-gold was used as ligand. We conclude, that in vivo somatostatin receptor scintigraphy may aid in the pre-operative differential diagnosis of skull base tumours

  14. Recurrent urinary tract infections in young children: role of DMSA scintigraphy in detecting vesicoureteric reflux

    International Nuclear Information System (INIS)

    Awais, Muhammad; Rehman, Abdul; Nadeem, Naila; Zaman, Maseeh Uz

    2015-01-01

    Performing micturiting cystourethrography (MCUG) in young children with recurrent urinary tract infections is controversial with discrepancy among the major guidelines. Previous studies have shown that a normal dimercaptosuccinic acid (DMSA) scintigraphy may avoid the need of performing MCUG for detecting vesicoureteric reflux in children with first febrile urinary tract infection. However, the role of DMSA for ruling out vesicoureteric reflux in children with recurrent urinary tract infections has not been studied. Approval from institutional ethical review committee was sought and the requirement of informed consent was waived. A total of 50 children under the age of 10 years with recurrent urinary tract infections underwent MCUG scan within 3 months of DMSA scan from January 2011 to September 2012 at our institution. Diagnosis of recurrent urinary tract infections and grading of vesicoureteric reflux was according to previously established standards. Abnormalities on DMSA scan - scarring, hydronephrosis and reduced differential renal function - were compared with presence of vesicoureteric reflux on MCUG. High-grade vesicoureteric reflux was noted on MCUG in 22 (44%) cases. The findings on DMSA included hydronephrosis and scarring in 25 (50%) and 25 (50%) cases, respectively. Abnormalities on DMSA scan for detecting the presence of high-grade vesicoureteric reflux on MCUG examination had sensitivity, specificity, positive and negative predictive values of 95.45%, 35.71%, 53.85% and 90.91%, respectively. The positive and negative likelihood ratios were 1.48 and 0.13 respectively. DMSA scan had high overall sensitivity and negative predictive value with a low negative likelihood ratio for ruling out high-grade vesicoureteric reflux on MCUG, which may obviate the need of invasive MCUG along with its associated drawbacks. (orig.)

  15. Recurrent urinary tract infections in young children: role of DMSA scintigraphy in detecting vesicoureteric reflux

    Energy Technology Data Exchange (ETDEWEB)

    Awais, Muhammad; Rehman, Abdul; Nadeem, Naila [Aga Khan University Hospital, Department of Radiology, Karachi (Pakistan); Zaman, Maseeh Uz [Aga Khan University Hospital, Nuclear Medicine, Department of Radiology, Karachi (Pakistan)

    2014-07-04

    Performing micturiting cystourethrography (MCUG) in young children with recurrent urinary tract infections is controversial with discrepancy among the major guidelines. Previous studies have shown that a normal dimercaptosuccinic acid (DMSA) scintigraphy may avoid the need of performing MCUG for detecting vesicoureteric reflux in children with first febrile urinary tract infection. However, the role of DMSA for ruling out vesicoureteric reflux in children with recurrent urinary tract infections has not been studied. Approval from institutional ethical review committee was sought and the requirement of informed consent was waived. A total of 50 children under the age of 10 years with recurrent urinary tract infections underwent MCUG scan within 3 months of DMSA scan from January 2011 to September 2012 at our institution. Diagnosis of recurrent urinary tract infections and grading of vesicoureteric reflux was according to previously established standards. Abnormalities on DMSA scan - scarring, hydronephrosis and reduced differential renal function - were compared with presence of vesicoureteric reflux on MCUG. High-grade vesicoureteric reflux was noted on MCUG in 22 (44%) cases. The findings on DMSA included hydronephrosis and scarring in 25 (50%) and 25 (50%) cases, respectively. Abnormalities on DMSA scan for detecting the presence of high-grade vesicoureteric reflux on MCUG examination had sensitivity, specificity, positive and negative predictive values of 95.45%, 35.71%, 53.85% and 90.91%, respectively. The positive and negative likelihood ratios were 1.48 and 0.13 respectively. DMSA scan had high overall sensitivity and negative predictive value with a low negative likelihood ratio for ruling out high-grade vesicoureteric reflux on MCUG, which may obviate the need of invasive MCUG along with its associated drawbacks. (orig.)

  16. Assessment of technetium-99m technegas scintigraphy for ventilatory impairment in pulmonary emphysema. Comparison of planar and SPECT images

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Takahashi, Kazue

    1997-01-01

    Pulmonary emphysema can be diagnosed easily by X-ray CT (CT) as a low attenuation area. Recently Tc-99m-Technegas (Technegas) has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of planar and SPECT images by using Technegas scintigraphy in patients with pulmonary emphysema. Technegas scintigraphy, CT and pulmonary function tests were performed in 20 patients (males, age 32-78 years). We classified the findings of Technegas images into 4 grades. Comparing planar and SPECT images of Technegas, more detailed findings were shown by SPECT than by planar images in mild cases (6 cases, 30%). In more severe cases, findings of SPECT and planar images were equivalent (14 cases, 70%). The degree of abnormal findings obtained by SPECT was equivalent to that obtained by CT in severe cases (6 cases, 30%). SPECT should be excluded in advanced stages as indicated by planar images. (author)

  17. Whole Body MR Imaging Versus 99mTC-Methylene Diphosphonate Scintigraphy in Detection of Skeletal Metastases

    International Nuclear Information System (INIS)

    SALEM, H.T.M.

    2009-01-01

    The introduction of new chemotherapy protocols, which include both marrow and stem cell transplantation, has increased the demand for accurate and early detection of skeletal metastases, particularly metastases to marrow (Eustace et al., 1997). All existing methods of detection skeletal metastases have limitations. Metastases to bone only become apparent on radiographs after the loss of more than 50% of the bone mineral content at the site of the disease. Although CT allows earlier detection of cortical destruction by imaging in contiguous tomographic slices, its ability to detect early deposits in marrow is limited (Gold et al., 1990). The use of bone scintigraphy in the assessment of skeletal abnormalities is based on increased sensitivity in detecting abnormalities before other diagnostic imaging techniques. The pitfall of bone scintigraphy is its lack of specificity. There must be close correlation of scintigraphic findings with those of other imaging modalities (Nadel et al., 2001). The high spatial resolution and excellent soft-tissue contrast make MR imaging an ideal tool for the detection of osseous lesions. The limited field of view must be considered a major limitation of conventional MR imaging. Furthermore MR imaging approaches were limited by long acquisition times. Development in MR imaging, such as the development of turbo sequences, have led to renewed interest in MR imaging as a potential whole body screening tool (Johnson et al., 1997 and Lauenstein et al., 2004).

  18. Detection of phenazepam in impaired driving.

    Science.gov (United States)

    Kerrigan, Sarah; Mellon, Monica Brady; Hinners, Paige

    2013-10-01

    Phenazepam is a potent 1,4-benzodiazepine that has gained notoriety among recreational drug users. First synthesized in Ukraine in the 1970s, it is one of the most commonly prescribed benzodiazepines in Russia and other commonwealth of independent state nations, where it is used therapeutically as a prescription drug. Reports of abuse are widespread and several European countries have taken steps to control its use. However, in the USA, phenazepam is not approved for use by the Food and Drug Administration, nor scheduled under the Federal Controlled Substances Act. Phenazepam is widely available on the Internet, and recreational drug users report a potency 10-fold greater than that of nordiazepam. We report a case of a 24-year-old male driver who was apprehended for impaired driving following a two-vehicle crash. The subject exhibited slurred speech and profound psychomotor impairment. Toxicology testing revealed phenazepam at a concentration of 76 ng/mL in blood, with no other drugs detected. This case report not only demonstrates the potential for adverse traffic safety consequences following the misuse of phenazepam, but also highlights the importance of analytical factors such as immunoassay cutoff concentration, cross-reactivity and comprehensive screening using chromatographic-based techniques for impaired driving investigations.

  19. [Protein losing enteropathy (PLE) detected by Tc99m-labelled human serum albumin abdominal scintigraphy--case report].

    Science.gov (United States)

    Hubalewska-Hoła, Alicja; Sowa-Staszczak, Anna; Szczerbiński, Tomasz; Lis, Grzegorz; Huszno, Bohdan; Szybiński, Zbigniew

    2003-01-01

    Protein losing enteropathy (PLE) is a gastrointestinal disorder that is associated with excessive loss of plasma protein into the gut resulting from abnormal mucosal permeability. The disease is usually caused by inflammation. The loss of protein in PLE is a nonselective process affecting albumin, globulin and transferrin. Abdominal scintigraphy with human serum albumin marked by Tc99m seems to be an easy and sensitive method for diagnosing PLE. An 4-year-old girl was presented to an outside Pediatric Department due to hypoproteinemia and recurrent pneumonia which had caused several prior hospitalizations. The laboratory tests revealed hypoproteinemia, hypoalbuminemia, low level of IgG, sideropenia, and a decreased level of T lymphocytes. The loss of protein into the gut was confirmed by fecal clearance of alfa-1 antitrypsin. Only nonspecific inflammation was detected by biopsy of the small intestine. These clinical and laboratory findings, quickly decreasing IgG and albumin levels in spite of i.v. supplementation and the lack of proteinuria permitted PLE diagnosis. The abdominal scintigraphy was planned to assess and localise protein losing through GIT and for strategy of possible surgical treatment. Abdominal dynamic scintigraphy was performed immediately after the injection of 300 MBq Tc99m human albumin. 90 images were taken within 180 minutes. Delayed abdominal images were obtained 6 and 24 hours after the tracer injection. Anterior abdominal scintigraphy showed pathological activity of Tc99m-albumin in small bowel in the upper left segment of the abdomen in the 40th minute after injection. Extensive accumulation of albumin was seen in the 160th minute. Delayed images, after 3 and 6 hours, revealed translocation of the tracer into the lower right abdominal segment. The further passage and tracer concentration was detected in ascendant and transverse colon. Based on the laboratory tests and scintigraphic images the girl was suspected to have segmental

  20. [Lung scintigraphy].

    Science.gov (United States)

    Schümichen, Carl; Schmidt, Matthias; Krause, Thomas

    2018-06-01

    The S1 guideline for lung scintigraphy has been updated and extended in order to emphasize the advantages oft the method in detecting acute pulmonary embolism (PE) in the periphery oft the lung (subsegmental PE), in underlying subacute and chronic pulmonary disorders, as well as in detecting chronic LE (CTEPH). Method of choice is ventilation / perfusion (V/P) SPECT or V/P SPECT/CT with even higher specificity. Because of its high sensitivity, a threshold (V/P mismatch in at least one segment or two subsegments) is introduced to avoid overtreatment. In case of a change in the therapeutic approach (observation only instead of anticoaculation) the threshold can be omitted. New data concerning the clinical and therapeutical impact of subsegmental PE are included, the chapters open questions have been extented. Other indications for V/P SPECT (secondary diagnoses, abnormalities in pulmonary perfusion, prediction of postoperative lung function) are presented with new data. Schattauer GmbH.

  1. Study of the association between left ventricular diastolic impairment and cardiac autonomic neuropathy in diabetic patients using [123I] metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Suzuki, Rokuro; Tanaka, Shiro; Tojo, Osamu; Ishii, Tomofusa; Sato, Toshihiko; Fujii, Satoru; Tumura, Kei.

    1994-01-01

    The association between left ventricular (LV) diastolic dysfunction and myocardial MIBG accumulation was investigated. The subjects were 14 Type II diabetic patients who had no evidence of ischemic heat disease, LV hypertrophy or dilated cardiomyopathy as determined by exercise Tl-201 myocardial scintigraphy and echocardiography. In 14 diabetic patients, isovolumic relaxation time (IRT) was measured by M-mode echocardiography, and the subjects were subdivided into two groups: Group1, 8 patients with impaired left ventricular diastolic function (IRT≥80 msec), and Group 2, 6 patients with normal left ventricular diastolic function (IRT 123 I-MIBG myocardial scintigraphy was performed, and the myocardial accumulation of 123 I-MIBG was investigated. The ratio of myocardial to mediastinal MIBG uptake was significantly (p<0.01) lower in Group 1 than in Group 2. And scintigraphic defects were significantly (p<0.05) more numerous in Group 1 than in Group 2. Patients in Group 1 had a greater frequency of cardiac autonomic neuropathy evaluated by QTc interval and coefficient of variation of R-R interval, when compared with Group 2. These data suggest that, in diabetic patients with no evidence of ischemic heart disease, LV hypertrophy or dilated cardiomyopathy, impairment of left ventricular diastolic function is associated with cardiac autonomic neuropathy. (author)

  2. Detection of angina-related coronary artery in patients with unstable angina pectoris by using 123I-BMIPP myocardial scintigraphy

    International Nuclear Information System (INIS)

    Oka, Toshiaki; Inoue, Seiji; Asano, Ryuta; Handa, Atsushi; Iguchi, Nobuo; Sumiyoshi, Tetsuya; Hosoda, Saichi; Kobayashi, Hideki; Kusakabe, Kiyoko.

    1996-01-01

    To evaluate the diagnostic accuracy of detection of angina-related coronary arteries in patients with unstable angina pectoris. Twenty patients with unstable angina pectoris underwent 123 I-BMIPP scintigraphy at rest. A mean duration from last anginal attack to 123 I-BMIPP scintigraphy was 4.8±3.2 days. Seventeen of 20 angina-related coronary territories were detected by reduced 123 -BMIPP uptake. The sensitivity and specificity for detection of angina-related coronary arteries were 85% and 95%, respectively. The decrease in myocardial uptake of 123 I-BMIPP agreed with the decrease in regional wall motion by using ultrasonic echocardiography. 123 I-BMIPP scintigraphy may be useful for detection of angina-related coronary artery in a routine clinical examination in patients with unstable angina pectoris. (author)

  3. The usefulness of 99mTc-Technegas scintigraphy for diagnosing pulmonary impairment caused by pulmonary emphysema

    International Nuclear Information System (INIS)

    Satoh, Katashi; Takahashi, Kazue; Kobayashi, Takuya; Yamamoto, Yuka; Nishiyama, Yoshihiro; Tanabe, Masatada

    1998-01-01

    X-ray computed tomography (CT) has been used for diagnosis of pulmonary emphysema because it can reveal the morphology of low attenuation areas. Recently, 99m Tc-Technegas imaging, one of several types of scintigraphic techniques, has been used for ventilation scintigraphy. Technegas scintigraphy was performed on 15 patients with pulmonary emphysema, and we compared the extent and degree of abnormal findings on Technegas scintigraphy with the extent of low attenuation areas shown by CT. We classified the findings of Technegas imaging into three grades, from mild to severe, according to the extent of peripheral irregularity and central hot spot formation. We also classified the findings of CT as centrilobular emphysema into three grades from mild to severe according to the extent of low attention areas in the peripheral lung fields. In 5 cases, CT and Technegas assessment resulted in equivalent diagnoses. In eight cases, Technegas images showed more detailed findings than CT images. In the two remaining cases, which were diagnosed as panlobular emphysema on CT, Technegas images showed the severe stage. Technegas scintigraphy was useful for diagnostic assessment of pulmonary emphysema, especially for panlobular emphysema, which is difficult to distinguish from the normal lung condition by CT assessment. (author)

  4. The usefulness of bone-marrow scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Sone, Teruki; Yoneda, Masaya; Tomomitsu, Tatsushi; Yanagimoto, Shinichi; Muranaka, Akira; Morita, Rikushi; Saito, Noriaki; Tanaka, Hiroyoshi

    1985-01-01

    We used a combination of bone and bone-marrow scintigraphy to study 25 patients with prostatic cancer. Of the 18 cases whose sup(99m)Tc-methylene diphosphonate (MDP) bone scans showed hot spots in the lower lumbar region of the spine and/or the pelvic bone, 8 had normal bone-marrow scintigrams. These 8 patients, were subsequently shown to have senile, degenerative changes of the spine. On the other hand, in 9 of the 10 patients whose bone-marrow scintigrams showed accumulation defects, follow-up study and characteristic X-ray findings confirmed the presence of metastases. In all 6 cases with extensive bone metastases shown by sup(99m)Tc-MDP bone scintigraphy, sup(99m)Tc-sulphur-colloid bone-marrow scintigraphy showed multiple accumulation defects. In conclusion, bone-marrow scintigraphy was found to be useful in distinguishing metastatic lesions from benign degenerative changes in the cases with suspected bone involvement, as well as in evaluating equivocal lesions in the pelvis. (orig.)

  5. The use of bone scintigraphy to detect active Hansen's disease in mutilated patients

    Energy Technology Data Exchange (ETDEWEB)

    Braga, F.J.H.N. [Seccao de Medicina Nuclear do Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, USP (Brazil); Departamento de Fisica e Biofisica, Instituto de Biociencias, UNESP, Botucato (Brazil); Foss, N.T.; Ferriolli, E. [Departamento de Clinica Medica da Faculdade de Medicina de Ribeirao Preto, USP (Brazil); Pagnano, C. [Secretaria da Saude, Ribeirao Preto (Brazil); Miranda, J.R.A.; De Moraes, R. [Departamento de Fisica e Biofisica, Instituto de Biociencias, UNESP, Botucato (Brazil)

    1999-11-01

    Mutilation of extremities was very frequent in patients affected by leprosy in the past; although it is now much less common, it is still seen, mainly in patients with long-term disease. In general, mutilation of the nose and ears is caused by the bacillus and mutilation of the hands and feet a consequence of chronic trauma. Leprosy must be chronically treated and any decision to interrupt therapy is based on laboratory tests and biopsy. Scintigraphy is a non-invasive procedure which could be of great value in to determining disease activity. We studied eight patients (five males and three females, aged 64-73 years) who presented with mutilation of the nose (2), ear (1), feet (3) or foot and hand (2). Conventional three-phase bone scintigraphy (750 MBq) and X-ray examinations of the affected areas were performed in all patients. Bone scintigraphy was abnormal in four patients (the presence of bacilli was confirmed by biopsy in two of them), and normal in the other four. In all patients except for the one with ear mutilation, radiography only showed the absence of bone. We conclude that bone scintigraphy is very useful to determine disease activity in cases of mutilation caused by leprosy. It seems to be superior to conventional radiography and may enable bone biopsies to be avoided. (orig.)

  6. The use of bone scintigraphy to detect active Hansen's disease in mutilated patients

    International Nuclear Information System (INIS)

    Braga, F.J.H.N.; Foss, N.T.; Ferriolli, E.; Pagnano, C.; Miranda, J.R.A.; De Moraes, R.

    1999-01-01

    Mutilation of extremities was very frequent in patients affected by leprosy in the past; although it is now much less common, it is still seen, mainly in patients with long-term disease. In general, mutilation of the nose and ears is caused by the bacillus and mutilation of the hands and feet a consequence of chronic trauma. Leprosy must be chronically treated and any decision to interrupt therapy is based on laboratory tests and biopsy. Scintigraphy is a non-invasive procedure which could be of great value in to determining disease activity. We studied eight patients (five males and three females, aged 64-73 years) who presented with mutilation of the nose (2), ear (1), feet (3) or foot and hand (2). Conventional three-phase bone scintigraphy (750 MBq) and X-ray examinations of the affected areas were performed in all patients. Bone scintigraphy was abnormal in four patients (the presence of bacilli was confirmed by biopsy in two of them), and normal in the other four. In all patients except for the one with ear mutilation, radiography only showed the absence of bone. We conclude that bone scintigraphy is very useful to determine disease activity in cases of mutilation caused by leprosy. It seems to be superior to conventional radiography and may enable bone biopsies to be avoided. (orig.)

  7. One-hour protocol stress myocardial scintigraphy. Prospective study of diagnostic accuracy for the detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Matsuda, Junko; Miyamoto, Nobuhide; Onitsuka, Hisamitsu; Ikushima, Ippei; Unoki, Toshihide; Takenaga, Makoto; Koiwaya, Yasushi; Eto, Tanenao

    1999-01-01

    A one-hour protocol for stress myocardial scintigraphy using technetium-99m-tetrofosmin (Tc-tetrofosmin) was compared with coronary arteriography for the detection of coronary artery stenosis in 90 consecutive patients without prior myocardial infarction, revascularization procedure or vasospastic angina. Tc-tetrofosmin stress myocardial scintigraphy acquired a rest image 20 min after intravenous administration of Tc-tetrofosmin (185 MBq, 1/5 vial) using a three-head gamma camera collecting 20-sec views over 360 deg. The stress test using bicycle ergometer was performed and administration of Tc-tetrofosmin (740 MBq, 4/5 vial) was repeated at the peak stress point. The stress image was acquired 15 min after the second injection with 5-sec views over 360 deg. Coronary arteriography revealed the presence of significant coronary artery stenosis (>75%) in 56 vessels of 45 patients, including 35 patients with single-vessel disease, 5 with two-vessel disease, 2 with three-vessel disease, and 3 with left main trunk disease. The overall sensitivity and specificity for the detection of coronary artery disease by visual analysis were 91.1% and 77.8%, respectively, and by quantitative analyses (using bull's-eye method) were 95.6% and 91.1%, respectively. The individual stenotic vessel sensitivities in the right coronary artery, left anterior descending artery, and left circumflex artery were 84.6%, 90.9%, and 78.6%, respectively. The specificities were 97.3%, 95.9%, and 100.0%, respectively. These results suggest that stress myocardial scintigraphy using the present new protocol is a promising approach for the detection of coronary artery stenosis. (author)

  8. Comparison of diffusion-weighted whole body MRI and skeletal scintigraphy for the detection of bone metastases in patients with prostate or breast carcinoma

    International Nuclear Information System (INIS)

    Gutzeit, Andreas; Doert, Aleksis; Froehlich, Johannes M.; Eckhardt, Boris P.; Meili, Andreas; Scherr, Patrick; Schmid, Daniel T.; Weymarn, Constantin A. von; Willemse, Edwin M.M.; Binkert, Christoph A.; Graf, Nicole

    2010-01-01

    To prospectively compare the diagnostic accuracy of diffusion-weighted whole body imaging with background whole body signal suppression (DWIBS) with skeletal scintigraphy for the diagnosis and differentiation of skeletal lesions in patients suffering from prostate or breast cancer. A diagnostic cohort of 36 patients was included in skeletal scintigraphy and 1.5 T DWIBS MRI. Based on morphology and signal intensity patterns, two readers each identified and classified independently, under blinded conditions, all lesions into three groups: (1) malignant, (2) unclear if malignant or benign and (3) benign. Finally, for the definition of the gold standard all available imaging techniques and follow-up over a minimum of 6 months were considered. Overall, 45 circumscribed bone metastases and 107 benign lesions were found. DWIBS performed significantly better in detecting malignant skeletal lesions in patients with more than 10 lesions (sensitivity: 0.97/0.91) compared to skeletal scintigraphy (sensitivity: 0.48/0.42). No statistical difference could be found between DWIBS (0.58/0.33) and skeletal scintigraphy (0.67/0.58) in the sensitivity values for malignant skeletal lesions in patients with less than 5 lesions. For benign lesions, scintigraphy scored best with a sensitivity of 0.93/0.87 compared to 0.20/0.13 for DWIBS. Interobserver agreement with Cohen's kappa coefficient was calculated as 0.784 in the case of scintigraphy and 0.663 for DWIBS. With respect to staging, in prostate and breast carcinoma, the DWIBS technique is not superior to skeletal scintigraphy, but ranks equally. However, in the cases with many bone lesions, markedly more metastases could be discovered using the DWIBS technique than skeletal scintigraphy. (orig.)

  9. 111In-Octreotide and 99mTc-MDP scintigraphy in the detection of bone lesions in Langerhans cell histiocytosis

    International Nuclear Information System (INIS)

    Hervas, I.; Bello, P.; Gonzalez-Cabezas, P.; Flores, D.; Perez-Velasco, R.; Torres, I.; Castel, V.; Mateo, A.; Canete, A.

    2002-01-01

    Aim: Langerhans cell histiocytosis (LCH) is a granulomatous disease which can involve multiples sites of the body. Diagnostic imaging is of utmost importance in the management of these patients. Since now radiographic skeletal survey and bone scintigraphy (BS) have been used to assess bone involvement (both with low specificity). Magnetic resonance and CT have been used to assess visceral involvement but with the limitation that can not give information about the functional status. Recently two groups of investigators (Lastoria et al. and Calming et al.) have proposed somatostatin receptor scintigraphy (SSRS) to detect active lesions and for monitoring the response to treatment, due to the somatostatin analogue octreotide binds to the cell membrane of activated lymphocytes expressing somatostatine receptors. The aim of this study is to assess bone and somatostatine receptor scintigraphy in the detection of bone involvement in LCH in children. Visceral involvement has not been assessed due to none of the patients presented it at the moment of the SRS. Methods: 17 scintigraphies (11 SSRS and 6 BS) were performed in seven patients (3 girls and 4 boys) aged at diagnosis: 18 month- 12 years (mean age 6,2 years). The findings obtained in the scintigraphies were compared with clinical evolution and other imaging techniques. Results: All the BS detected the diagnosed lesions, that decreased the uptake after the treatment. In three cases BS detected one unknown bone lesion. Two SSRS could not detect a lesion on right rib in two patients, both at the moment of diagnosis. SSRS was true negative in one patient (clinical and other imaging remission) and true positive in the other four cases. SSRS detected three new unknown bone lesions. SRSS showed decreased uptake after treatment and increased uptake in the relapses. Conclusions: Somatostatin receptor and Bone scintigraphy can be used to detect active LCH bone lesions in children and can help in monitoring the response to

  10. Skeleton scintigraphy in trauma

    International Nuclear Information System (INIS)

    Ansari, M.

    2002-01-01

    Skeletal trauma is common and presents both an opportunity and a problem in skeletal scintigraphy. The opportunity arises in the ability of skeletal scintigraphy to demonstrate abnormalities early after direct trauma. It is well recognized that the early detection of fractures in some sites cannot be reliably achieved by standard radiography, especially in the femoral neck and scaphoid bone. The problem comes in recognizing the effects of skeletal trauma when using skeletal scintigraphy for another purpose, such as the detection of metastatic disease. iatrogenic trauma to either the skeleton or soft tissues may be manifest scintigraphic ally. For example Craniotomy typically leaves a rim pattern at the surgical margin. Rib Retraction during thoracotomy can elicit periosteal reaction. Areas of the skeletal receiving curative levels of ionizing radiation (typically 4000 rads or greater) characteristically demonstrate decreased uptake within 6 months to 1 year after therapy. The generally high sensitivity of the skeletal scintigraphy seems to make it an ideal survey test in cases of suspected child abuse especially in which radiographs are unrevealing. Because of difficulties in obtaining a history of trauma from a preschool child or even eliciting a satisfactory description of the location and nature of the pain, skeletal scintigraphy provides a simple and reliable investigation in these children. Subtle trauma, such as that from stress fractures is often difficult to visualize on a plain radiograph. Skeletal scintigraphy is frequently positive at the time of clinical presentation. Skeletal scintigraphy is exquisitely sensitive to the remodeling process and typically shows abnormalities 1 to 2 weeks or more before the appearance of radiographic changes in stress fractures. The periosteal reaction can be visualized within hours of the injury. Insufficiency and fatigue fractures such as vertebral compression fracture, which is probably the most common consequence of

  11. Resting 123I-BMIPP scintigraphy for detection of organic coronary stenosis and therapeutic outcome in patients with chest pain

    International Nuclear Information System (INIS)

    Yamabe, Hiroshi; Fujiwara, Sei; Rin, Kouten; Ando, Makoto; Yokoyama, Mitsuhiro; Sakamoto, Takaaki; Ishida, Toshiharu; Itagane, Hiroshi; Mori, Takao

    2000-01-01

    Resting 123 I-BMIPP scintigraphy can detect coronary artery disease based on persistent abnormality of myocardial fatty acid metabolism after transient ischemia. The present study aimed to determine the value of resting 123 I-BMIPP scintigraphy in diagnosing coronary artery disease and predicting the therapeutic outcome in patients with chest pain symptom. Five hospitals participated in this study, and scintigraphic and angiographic studies were performed in 104 patients without myocardial infarction. Twenty of them had non-coronary artery disease (chest pain syndrome), 26 had stable effort angina, 35 had unstable angina with organic coronary lesions, and 23 had vasospastic angina without significant organic stenosis. Overall sensitivity for diagnosing angina pectoris (stable, unstable and vasospastic) was 45%, and overall specificity for excluding non-coronary artery disease was 80%. The incidence of positive 123 I-BMIPP was 54% among patients with organic coronary stenosis (50% in stable angina and 61% in unstable angina with organic stenosis), but it was low (22%) in vasospastic angina without organic stenosis. Patients with advanced coronary stenosis and multi-vessel disease were found to have a higher incidence of positive 123 I-BMIPP. A positive 123 I-BMIPP result was correlated with a higher rate of subsequent intervention therapy (catheter intervention or CABG) than a negative result (48% versus 27%, p=0.03 at one month; and 63% versus 35%, p=0.008 at one year). Resting 123 I-BMIPP scintigraphy was valuable in detecting advanced coronary lesions in angina patients associated with a high incidence of subsequent intervention therapy. (author)

  12. Scintigraphy in the detection of gastro-oesophageal reflux in children with caustic oesophageal burns: a comparative study with radiography and 24-h pH monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Oezcan, Z.; Erinc, R.; Dirlik, A. [Dept. of Nuclear Medicine, Ege University Medical Faculty, Izmir (Turkey); Oezcan, C.; Mutaf, O. [Dept. of Paediatric Surgery, Ege University Medical Faculty, Izmir (Turkey)

    2001-10-01

    Background: Caustic injury of the oesophagus not only causes luminal narrowing but is also responsible for longitudinal contraction, resulting in gastro-oesophageal reflux (GOR), which leads to failure of conventional therapy. Therefore, the development of GOR should be investigated periodically to direct appropriate management of these patients. Purpose: To determine the ability of scintigraphy to detect GOR in children with caustic oesophageal strictures in comparison with barium study and 24-h pH monitoring. Materials and methods: Seventeen children with caustic oesophageal injury underwent scintigraphy, an upper GI barium study and 24-h pH monitoring within the same week. Five patients were also investigated post-operatively for the assessment of surgical outcome after antireflux surgery. Results: On the whole, there was good correlation (r = 0.78, P < 0.00 l) between scintigraphy and 24-h oesophageal pH monitoring. Scintigraphy detected all but one (9/10) refluxing patients and also correctly identified all (7/7) non-refluxing patients. Barium studies demonstrated 6 out of 10 refluxing patients. There were no false-positive barium studies in non-refluxing patients. Post-operative studies demonstrated no evidence of GOR in surgically treated patients. Conclusions: Our results indicate that, by comparison with barium studies, scintigraphy is useful in the detection of GOR in cases with caustic oesophageal strictures and may be used as a screening modality for those under clinical follow-up. (orig.)

  13. 111In-labeled platelet scintigraphy and two-dimensional echocardiography for detection of left atrial appendage thrombi. Studies in a new canine model

    International Nuclear Information System (INIS)

    Vandenberg, B.F.; Seabold, J.E.; Conrad, G.R.; Kieso, R.; Johnson, J.; Fox-Eastham, K.; Ponto, J.; Bruch, P.; Kerber, R.E.

    1988-01-01

    111In-labeled platelet scintigraphy and two-dimensional echocardiography were performed in 40 dogs to determine the ability of the two techniques to detect left atrial appendage thrombi. Thrombi were induced in 33 dogs that were classified into two groups, acute or chronic, according to the time of labeled-platelet injection after thrombus induction. In the acute group (17 dogs), platelets were injected 24 hours after thrombus induction. In the chronic group (16 dogs), platelets were injected 4-8 days after thrombus induction. Sham thoracotomies were performed on seven additional control dogs who did not receive thrombin injections. Analog and blood pool-corrected 111In-labeled platelet scintigraphy images were obtained 4-72 hours later. Closed-chest two-dimensional echocardiography was performed before thoracotomy and repeated at the time of scintigraphy. The location and size of each thrombus were verified at autopsy. Two-dimensional echocardiography detected three of 17 acute (mean volume, 1.2 +/- 1.0 cc) and three of 10 chronic (mean volume, 0.4 +/- 0.3 cc; p less than 0.025) left atrial appendage thrombi. 111In-labeled platelet scintigraphy detected all 17 acute thrombi but only two of 10 chronic thrombi. The measured radioactivity levels of the excised thrombi were 1,949 +/- 1,665 cpm/clot/dose in group 1 and 228 +/- 213 cpm/clot/dose in group 2 (p less than 0.005). In this model, 111In-labeled platelet scintigraphy was able to detect acute left atrial appendage thrombi that could not be identified by two-dimensional echocardiography. Both techniques showed poor sensitivity for detection of chronic thrombi. The decline in sensitivity of 111In-labeled platelet scintigraphy for detection of older thrombi is probably due to diminished labeled-platelet incorporation

  14. Influence of bladder fullness on the detection of urinary tract obstruction by dynamic renal scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Cosenza, Nathalia Novaes; Lau, Fabio; Lima, Mariana Cunha Lopes; Amorim, Barbara Juarez; Mosci, Camila; Lima, Marcelo Lopes; Ramos, Celso Dario, E-mail: nathalia_cosenza@hotmail.com [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2017-07-15

    Objective: To investigate the influence of bladder fullness on the diagnosis of urinary tract obstruction during dynamic renal scintigraphy with a diuretic stimulator. Materials and Methods: We studied 82 kidneys in 82 patients submitted to dynamic renal scintigraphy with a diuretic stimulator. We compared the proportional elimination of the radiopharmaceutical {sup 99m}Tc-DTPA from the kidneys before and after bladder emptying in post-diuretic images, classifying each image as representing an obstructed, indeterminate, or unobstructed kidney. Results: The overall elimination of {sup 99m}Tc-DTPA from the kidneys was 10.4% greater after bladder emptying than before. When the analysis was performed with a full bladder, we classified 40 kidneys as obstructed, 16 as indeterminate, and 26 as unobstructed. When the 40 kidneys classified as obstructed were analyzed after voiding, 11 were reclassified as indeterminate and 3 were reclassified as unobstructed. Of the 16 kidneys classified as indeterminate on the full-bladder images, 13 were reclassified as unobstructed after voiding. Conclusion: In dynamic renal scintigraphy with a diuretic stimulator, it is important to obtain images after voiding, in order to perform a reliable analysis of the proportional excretion of {sup 99m}Tc-DTPA from the kidneys, avoiding possible false-positive results for urinary tract obstruction. (author)

  15. Influence of bladder fullness on the detection of urinary tract obstruction by dynamic renal scintigraphy

    International Nuclear Information System (INIS)

    Cosenza, Nathalia Novaes; Lau, Fabio; Lima, Mariana Cunha Lopes; Amorim, Barbara Juarez; Mosci, Camila; Lima, Marcelo Lopes; Ramos, Celso Dario

    2017-01-01

    Objective: To investigate the influence of bladder fullness on the diagnosis of urinary tract obstruction during dynamic renal scintigraphy with a diuretic stimulator. Materials and Methods: We studied 82 kidneys in 82 patients submitted to dynamic renal scintigraphy with a diuretic stimulator. We compared the proportional elimination of the radiopharmaceutical "9"9"mTc-DTPA from the kidneys before and after bladder emptying in post-diuretic images, classifying each image as representing an obstructed, indeterminate, or unobstructed kidney. Results: The overall elimination of "9"9"mTc-DTPA from the kidneys was 10.4% greater after bladder emptying than before. When the analysis was performed with a full bladder, we classified 40 kidneys as obstructed, 16 as indeterminate, and 26 as unobstructed. When the 40 kidneys classified as obstructed were analyzed after voiding, 11 were reclassified as indeterminate and 3 were reclassified as unobstructed. Of the 16 kidneys classified as indeterminate on the full-bladder images, 13 were reclassified as unobstructed after voiding. Conclusion: In dynamic renal scintigraphy with a diuretic stimulator, it is important to obtain images after voiding, in order to perform a reliable analysis of the proportional excretion of "9"9"mTc-DTPA from the kidneys, avoiding possible false-positive results for urinary tract obstruction. (author)

  16. Noninvasive detection of coronary artery disease by dipyridamole-loading 201thallium myocardial scintigraphy

    International Nuclear Information System (INIS)

    Hamashige, Naohisa; Doi, Yoshinori; Yonezawa, Yoshihiro; Odawara, Hiroaki; Ozawa, Toshio; Akagi, Naoki; Yoshida, Shoji; Maeda, Tomoho

    1986-01-01

    Fifty patients with suspected coronary artery disease (CAD) were given i.v. infusion of 0.568 mg/kg of dipyridamole (DP) for 4 min in the supine position, and were loaded by stepping. Myocardial DP scanning (DP scintigraphy) was then performed with i.v. injection of 3 mCi of Tl-201 chloride. Findings were compared with those of coronary angiography and treadmill ECG. DP scintigraphy had higher sensitivity (90 %) and specificity (95 %) than treadmill ECG (76 % and 67 %) in diagnosing a ≥ 75 % coronary stenosis. Twenty nine patients had significant CAD: Reversible defects were associated with chest pain in 79 %, and with ST depression in 76 %. Not only relative differences in blood flow between the normal and diseased sites but also ischemia was suggested to be responsible for these defects. Increased rate pressure product by DP scintigraphy was slight (34 %) compared with that by treadmill ECG (105 %), suggesting a strong involvement of redistribution of coronary blood flow in the occurrence of ischemia. Increased myocardial oxygen consumption due to stepping was considered as the cause of ischemia as well, because the incidence of chest pain and ST depression was higher than previously reported. Chest pain and ST depression improved by i.v. injection of aminophylline. (Namekawa, K.)

  17. Scintigraphy of renal transplant

    International Nuclear Information System (INIS)

    Ramackers, J.M.; Marrast, A.C.; Touraine, J.L.; Peyrin, J.O.

    1995-01-01

    Scintigraphy is useful for monitoring perfusion and function of renal transplant, as well as for diagnosing miscellaneous surgical. This non-invasive imaging technique, which uses no deleterious products, is an attractive alternative for patients. This is especially true for those patients in early post-transplant course, with immunity depression and often impairment of renal function. Otherwise, multiple indices with a large range of inter-patient values has not favoured a methodological and interpretative consensus. Furthermore, the poor specificity of renogram patterns does not allow for discrimination of all etiologies with only one scintigraphy. Nevertheless, follow-up with iterative scintigraphy may be helpful due to the high intra-patient reproducibility and to the early appreciate change of parameters, according to clinical and histological renal post-transplant outcome. (authors). 43 refs., 8 figs

  18. Adrenal scintigraphy

    International Nuclear Information System (INIS)

    Beierwaltes, W.H.

    1979-01-01

    The following items are discussed:anatomy and physiology of adrenal glands, clinical indications of scintigraphy, radiobiology and radiochemistry, scintigraphic imaging, adrenocortical hyperfunction, aldosteronism and hypertension associated with low renin level, excess of androgen, adrenocortical hyperfunction and future perspectives of adrenal scintigraphy. (M.A.) [pt

  19. Lung scintigraphy

    International Nuclear Information System (INIS)

    Dalenz, Roberto.

    1994-01-01

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies

  20. Myocardial scintigraphy with thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Lichte, H [Zentralkrankenhaus Gauting (Germany, F.R.). Nuklearmedizinische Abt.

    1977-04-01

    Myocardial scintigraphy with /sup 201/thallium is a non-invasive method for detection of myocardial infarction and coronary heart disease. Redistribution-analysis as a sequential-scintigraphy of an exercise-scan permits to distinguish between myocardial scars and coronary vessel disease.

  1. Dynamic scintigraphy of the kidneys in chronic pyelonephritis of patients with artrial hypertension

    International Nuclear Information System (INIS)

    Kramer, A.A.; Belichenko, O.I.; Arabidze, G.G.

    1985-01-01

    It has been shown that latent renal diseases are detected by sectoral scintigraphy earlier than by other methods, and the former acquires particular importance when the only sign of disease is arterial hypertension. Early diagnosis of latent pyelonephritis makes this method especially valuable both for the selection of patients for further thorough examination and for the start of adequate therapy. Scintigraphy serves as a reliable criterion for the evaluation of the therapeutic efficacy in patients with chronic pyelonephritis (CP). Changes of scintigraphy parametres coincide quite exactly with the changed level of arterial pressure, concentration and nitrogen clearing function of the kidneys during treatment. This method (sectoral scintigraphy) is very important when used over time in CP patiens with chronic renal insufficiency making it possible to detect with a sufficient deg ree of significance the improvement as well as impairment of renal function which is a crucial point for the choice of further therapeutic tactics

  2. Adrenal scintigraphy

    International Nuclear Information System (INIS)

    Veen, E.A. van der.

    1978-01-01

    The visualization of functioning adrenocortical tissue by scintigraphy became possible with the introduction of radioiodinated cholesterol derivatives. According to the literature, there is evidence that one of these iodinated cholesterols, 6-β-iodomethyl-nor-cholesterol, concentrates in the adrenal cortex to a much greater extent than 131 I-19-odocholesterol. Results comparing both radiopharmaceuticals are described. The authors investigated the possibility of increasing the uptake of iodinated cholesterol using simultaneous ACTH and the 'cholesterol side-chain cleavage enzymeblocker': aminoglutethimide. The results of adrenal scintigraphy performed in 37 patients are described. Finally, the literature on adrenal scintigraphy is reviewed, and results reported in various studies are compared. (Auth.)

  3. Pyrophosphate scintigraphy and other non-invasive methods in the detection of cardiac involvement in some systemic connective tissue diseases

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Bradna, P.; Pospisil, M.; Kubicek, J.; Vizda, J.; Kafka, P.; Palicka, V.; Mazurova, Y.

    1987-02-01

    Thirteen patients with systemic lupus erythematosus, 8 patients with polymyositis, and 6 patients with spondylitis ankylopoetica (Bechterew's disease) underwent clinical cardiologic examination and scintigraphy of the myocardium (/sup 99m/Tc-pyrophosphate), ECG, echocardiography, polygraphy, and their blood pressure was taken. The aim of the study was to ascertain how such a combination of non-invasive examinations can help in recognizing a cardiac involvement. In systemic lupus erythematosus cases one or more positive findings were revealed in 9 patients (69%), in 4 patients all examinations were negative (31%). Four patients (50%) with polymyosits had positive findings. In patients with spondylitis ankylopoetica positive findings occurred in 2 cases (33%). The study has shown that a combination of non-invasive cardiologic methods increases the probability of detecting cardiac involvement in systemic connective tissue diseases.

  4. Pyrophosphate scintigraphy and other non-invasive methods in the detection of cardiac involvement in some systemic connective tissue diseases

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Bradna, P; Pospisil, M; Kubicek, J; Vizda, J; Kafka, P; Palicka, V; Mazurova, Y

    1987-02-01

    Thirteen patients with systemic lupus erythematosus, 8 patients with polymyositis, and 6 patients with spondylitis ankylopoetica (Bechterew's disease) underwent clinical cardiologic examination and scintigraphy of the myocardium (/sup 99m/Tc-pyrophosphate), ECG, echocardiography, polygraphy, and their blood pressure was taken. The aim of the study was to ascertain how such a combination of non-invasive examinations can help in recognizing a cardiac involvement. In systemic lupus erythematosus cases one or more positive findings were revealed in 9 patients (69%), in 4 patients all examinations were negative (31%). Four patients (50%) with polymyosits had positive findings. In patients with spondylitis ankylopoetica positive findings occurred in 2 cases (33%). The study has shown that a combination of non-invasive cardiologic methods increases the probability of detecting cardiac involvement in systemic connective tissue diseases.

  5. Indium-111 platelet scintigraphy and two-dimensional echocardiography for detection of left ventricular thrombus: influence of clot size and age

    International Nuclear Information System (INIS)

    Seabold, J.E.; Schroeder, E.C.; Conrad, G.R.

    1987-01-01

    Two-dimensional echocardiography and indium-111 platelet scintigraphy were performed on 50 dogs to determine the influence of clot age and size on the detection of experimentally induced left ventricular mural thrombus. Thrombus was induced by apical infarction and injection of a sclerosing agent and thrombin. The animals were classified into four groups according to the time of indium-111 platelet injection after thrombus induction: Group I (17 dogs, 1/2 hour after induction; 3 dogs, before induction), Group II (12 dogs, 24 hours after induction) and Group III (12 dogs, 1 week after induction). In Group IV (six control dogs) apical infarction was produced, but thrombin was not injected; indium-111 platelets were injected 1/2 to 1 hour after infarction. The dogs were studied by indium-111 platelet scintigraphy and by two-dimensional echocardiography 1/2 to 5 hours (Group I) and 1 to 5 and up to 72 hours (Groups II to IV) after platelet administration and before death was induced. Two-dimensional echocardiography showed the best overall sensitivity for detection of acute thrombus (97%; 29 of 30). The sensitivity of indium-111 platelet scintigraphy was 86% (18 of 21) for clots greater than or equal to 0.08 ml in size, and 67% (20 of 30) for detection of all clots. Thrombus did not form in 14 dogs of Groups I to III and in 6 of 6 control dogs. The specificity of scintigraphy was 100% (20 of 20) compared with 80% (16 of 20) for echocardiography. Echocardiography was more sensitive than scintigraphy for detecting very small clots in this experimental model

  6. Lacrimal scintigraphy in the diagnosis of epiphora

    International Nuclear Information System (INIS)

    Hanna, I.T.; MacEwen, C.J.; Kennedy, N.

    1992-01-01

    The value of lacrimal scintigraphy in the assessment of nasolacrimal duct obstruction was determined by comparing the results with syringing in 67 patients (83 eyes). As expected, of 28 lacrimal drainage systems which were obstructed on syringing, 23 (82%) had abnormalities of tear drainage on scintigraphy. However, in 55 lacrimal drainage systems that were patent on syringing, 19 (35%) were normal, but in 36 (65%) abnormalities not apparent on syringing were detected on scintigraphy. Thus scintigraphy is a very useful technique in the assessment of nasolacrimal duct obstruction particularly in systems patent on syringing. Since the site of obstruction can be determined, lacrimal scintigraphy can facilitate the planning of the appropriate surgery. (author)

  7. A case of a desmoid tumor with an uretertumoral fisttula detected on renal scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Hyun Woo; Lee, Kyu Taek; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2016-11-15

    Desmoid tumors are rare benign tumors with aggressive fibroblastic proliferation. Although desmoid tumors do not metastasize, they have locally aggressive features and can cause a urinary fistula. Here, we report a case of a 35-year-old woman with Gardner syndrome who was diagnosed with an intra-abdominal desmoid tumor 1 year previously and who presented with a newly developed cystic mass lesion on a computed tomography scan. The cystic mass lesion was clinically diagnosed as an urinoma from the right ureterotumoral fistula; thus, surgical resection of the mass lesion was planned. However, Tc-99m diethylenetriamine pentaacetic acid renal scintigraphy revealed bilateral ureterotumoral fistulas; hence, the treatment plan was changed to conservative management.

  8. Symptomatic hypophosphataemic osteomalacia secondary to the treatment with iron carboxymaltose detected in bone scintigraphy.

    Science.gov (United States)

    Sangrós Sahún, M J; Goñi Gironés, E; Camarero Salazar, A; Estébanez Estébanez, C; Lozano Martínez, M E

    The development of hypophosphataemic osteomalacia has been linked with several treatments, mainly antiretroviral and intravenous iron administration. The frequency of the hypophosphataemia requires monitoring the phosphate after the administration of iron carboxymaltose. We describe a case of a woman with no calcium-phosphorous metabolism disorder, to whom this treatment was prescribed for anaemia due to menorrhagia and intolerance to oral iron. She started with oligoarticular pain, which was spreading with a significant functional loss. The relationship with the administration of intravenous iron was discovered when scintigraphic findings together with laboratory results led to a diagnosis of hypophosphataemic osteomalacia. The patient responded satisfactorily to treatment with phosphate both clinically and in the follow-up bone scintigraphy. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  9. Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L.; Wastie, M.L.; Forster, I

    2001-03-01

    AIM: Post-arthroplasty knee pain is common and clinically it can be difficult to identify those patients with complications requiring active treatment. The aim of this study was to determine the usefulness of{sup 99}Tc{sup m}-MDP bone scintigraphy. METHOD: A retrospective study of all patients having a{sup 99}Tc{sup m}-MDP bone scintigram for a painful knee arthroplasty between 1993 and 1999 was performed. Bone scintigrams were classified as normal or abnormal by a single observer. The results of these investigations were correlated with clinical outcome. RESULTS: Seventy-five patients with painful knee arthroplasties were referred for investigation. A total of 80 bone scintigrams were performed. The average patient age was 66.2 years (42 female and 33 male). The mean time period between surgery and onset of knee pain was 3 years. A final clinical diagnosis based on arthroscopy, open surgery, and extended clinical follow-up was available for all patients. Forty-three (53.8%) of the scintigrams were normal and 37 (46.3%) abnormal. Two patients with a normal bone scintigram has loose prostheses. Thirteen patients with an abnormal study had normal prostheses on follow-up and these tended to be patients scanned less than a year after surgery. The sensitivity, specificity, positive predictive value and negative predictive value of an unequivocally normal or abnormal bone scintigram was 92.3, 75.9, 64.9 and 95.0%, respectively. The pattern of isotope uptake in the abnormal studies was not specific enough to reliably differentiate aseptic from septic loosening. CONCLUSION: Radionuclide bone scintigraphy is useful in the assessment of the painful knee arthroplasty. A negative bone scintigram is reassuring and makes loosening or infection unlikely. Smith, S.L. et al. (2001)

  10. Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement

    International Nuclear Information System (INIS)

    Smith, S.L.; Wastie, M.L.; Forster, I.

    2001-01-01

    AIM: Post-arthroplasty knee pain is common and clinically it can be difficult to identify those patients with complications requiring active treatment. The aim of this study was to determine the usefulness of 99 Tc m -MDP bone scintigraphy. METHOD: A retrospective study of all patients having a 99 Tc m -MDP bone scintigram for a painful knee arthroplasty between 1993 and 1999 was performed. Bone scintigrams were classified as normal or abnormal by a single observer. The results of these investigations were correlated with clinical outcome. RESULTS: Seventy-five patients with painful knee arthroplasties were referred for investigation. A total of 80 bone scintigrams were performed. The average patient age was 66.2 years (42 female and 33 male). The mean time period between surgery and onset of knee pain was 3 years. A final clinical diagnosis based on arthroscopy, open surgery, and extended clinical follow-up was available for all patients. Forty-three (53.8%) of the scintigrams were normal and 37 (46.3%) abnormal. Two patients with a normal bone scintigram has loose prostheses. Thirteen patients with an abnormal study had normal prostheses on follow-up and these tended to be patients scanned less than a year after surgery. The sensitivity, specificity, positive predictive value and negative predictive value of an unequivocally normal or abnormal bone scintigram was 92.3, 75.9, 64.9 and 95.0%, respectively. The pattern of isotope uptake in the abnormal studies was not specific enough to reliably differentiate aseptic from septic loosening. CONCLUSION: Radionuclide bone scintigraphy is useful in the assessment of the painful knee arthroplasty. A negative bone scintigram is reassuring and makes loosening or infection unlikely. Smith, S.L. et al. (2001)

  11. Executive cognitive impairment detected by simple bedside testing ...

    African Journals Online (AJOL)

    Aims. Cognitive impairment in people with type 2 diabetes is a barrier to successful disease management. We sought to determine whether impaired executive function as detected by a battery of simple bedside cognitive tests of executive function was associated with inadequate glycaemic control. Methods. People with ...

  12. The prevalence and the clinical characteristics of silent myocardial ischemia detected by stress thallium scintigraphy

    International Nuclear Information System (INIS)

    Matsuo, Hitoshi; Watanabe, Sachiro; Nishida, Yoshio

    1992-01-01

    The prevalence of silent myocardial ischemia was retrospectively assessed in a group of 100 consecutive patients with angiographically proved coronary artery disease, and diagnostic ECG, by symptom-limited exercise thallium-201 scintigraphy. Twenty-four patients had no evidence of ischemia despite adequate exercise level. So among 76 patients with exercise induced ischemia, only 33 patients (43%) stopped exercise due to anginal pain (symptomatic ischemia: Group 3). And 43 patients with asymptomatic ischemia composed of 23 patients (30%) with ECG change (Group 2B) and 20 patients (26%) without ECG change (Group 2A). Patients background including the history of old myocardial infarction and diabetes mellitus, were similar among Group 2A, 2B, and Group 3. Our Major observation was that the extent and severity of quantified SPECT perfusion defects was nearly identified between 3 groups. Thus in this study group, there was a rather high prevalence rate of silent ischemia (57%) by exercise thallium-201 criteria. Patients with silent ischemia, associated with positive and negative exercise ECG findings, and those with exercise angina had similar background and comparable amount of jeopardized myocardium. (author)

  13. Technetium-99m pyrophosphate scintigraphy for the detection of acute myocardial infarction. How useful is it

    International Nuclear Information System (INIS)

    Desai, A.G.; Berger, B.C.; Shin, Y.W.; Park, C.H.; Madsen, M.T.

    1985-01-01

    To evaluate the contribution of Tc-99m pyrophosphate scintigraphy (TPS) on the overall management of patients suspected of having acute myocardial infarction (AMI), hospital records of 58 consecutive patients who underwent TPS, were evaluated in depth. The results indicate that TPS was essential for the diagnosis of AMI in 16% of the patients. TPS was most rewarding in perioperative patients and in patients with borderline or uninterpretable electrocardiographic and enzyme changes. Also, in some cases, TPS was able to confirm or exclude the diagnosis of AMI prior to the confirmation by serial electrocardiograms (ECG) and serial enzyme changes. TPS was less rewarding in patients with clinically low index of suspicion for AMI. It may also be confusing in patients with high clinical likelihood of AMI and a history of prior myocardial infarction because of the possibility of persistently positive TPS in some of these patients. Considering the limitations of ECGs, the cardiac enzymes, and atypical clinical presentations in the patient population we evaluated, TPS appears to be fairly accurate when the scintigraphic findings are compared with the final diagnosis at the time of discharge from the hospital

  14. Vascular graft infection: Detection by 123I-labeled antigranulocyte antibody (anti-NCA95) scintigraphy

    International Nuclear Information System (INIS)

    Cordes, M.; Hepp, W.; Langer, R.; Pannhorst, J.; Hierholzer, J.; Felix, R.; Universitaetsklinikum Rudolf Virchow, Berlin

    1991-01-01

    A total of 40 scintigraphic examinations were performed after vascular reconstructive surgery in 27 patients in whom there was a clinical suspicion of vascular graft infection. Whole-body gamma camera images were obtained at 4 and 24 h after i.v. administration of 111 MBq 123 I-labeled antigranulocyte antibody Anti-NCA95. Scan results were interpreted without clincal information and were subsequently correlated with computed tomography. Prosthetic vascular graft infection was confirmed in 9 patients and excluded in 18 by surgical findings, bacteriology and/or clinical course. Scintigraphy revealed true-positive results in 16 of 40 and false-negative results in 1 of 40 examinations. True-negative results were found in 19 and 16, false-positive results in 4 and 7 examinations at 4 and 24 h p.i., resp. The sensitivity was calculated to be 94% for both early (4 h) and late (24 h) images whereas the specificity ws 83% and 70%, resp. In all cases the application of the murine antibody was safe and no side effects or complications were noted. Limitations of this diagnostic procedure are accumulations of granulocytes in hematomas which may be observed in the non-complicated early course following reconstructive surgery. (orig.) [de

  15. Detection of viability by percent thallium uptake with conventional thallium scintigraphy

    International Nuclear Information System (INIS)

    Imai, Kamon; Araki, Yasushi; Horiuchi, Kou-ichi; Yumikura, Sei; Saito, Satoshi; Ozawa, Yukio; Kan-matsuse, Katsuo; Hagiwara, Kazuo.

    1994-01-01

    Thallium myocardial scintigraphy (TMS) is used for diagnosis of viability in infarcted myocardium before coronary revascularization. Underestimation of viability by TMS has been reported by many investigators. To evaluate viability precisely, thallium re-injection method or 24 hour delayed imaging is performed. However, these techniques are not convenient and are difficult to perform in clinical practice. Percent T1-uptake method was developed for predicting myocardial viability. To evaluate usefulness of this method, TMS was performed before and after PTCA in 23 patients with myocardial infarction. Left ventricle was divided into 3 layers, then each layer was divided into 4 segments (12 segments in total). Forth three segments showed recovery of perfusion on TMS after PTCA. Viability in infarcted myocardium is predicted by 1) redistribution (RD), 2) %T1-uptake≥45% on the image immediately after exercise (TE), and 3) %T1-uptake≥45% on delayed image (TD). Sensitivity was RD: 60%, TE: 90% and TD: 95% (p<0.001 vs. RD). Specificity was RD: 74%, TE: 68%, and TD: 60% (NS). Predictive accuracy (PA) was RD: 69%, TE: 77%, TD: 73% (NS). Compared with RD, %T1-uptake, either TE or TD, increased sensitivity with slightly improved PA, but decreased specificity slightly. Therefore %T1-uptake would be a sensitive and useful predictor to find patients who are most likely to benefit from re-vascularization. (author)

  16. Myocardial perfusion scintigraphy in the detection of silent ischemia in asymptomatic diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Glaucia Celeste Rossatto [Clinica Diagnoson and Hospital Aristides Maltez, Salvador, BA (Brazil). Servicos de Medicina Nuclear; Pavin, Elizabeth Joao; Parisi, Maria Candida R. [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Internal Medicine. Service of Endocrinology; Coelho, Otavio Rizzi; Almeida, Raitany C. [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Internal Medicine. Service of Cardiology; Etchebehere, Elba Cristina Sa de Camargo; Ramos, Celso Dario, E-mail: cdramos@unicamp.br [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Radiology. Service of Nuclear Medicine; Camargo, Edwaldo Eduardo [Hospital Sirio-Libanes, Campinas, SP (Brazil). Service of Nuclear Medicine

    2013-01-15

    Objective: This study was aimed to evaluate myocardial perfusion in asymptomatic patients with type 1 (DM1) and type 2 diabetes mellitus (DM2) without previous diagnoses of coronary artery disease (CAD) or cerebral infarction. Materials and Methods: Fifty-nine consecutive asymptomatic patients (16 DM1, 43 DM2) underwent myocardial perfusion scintigraphy with {sup 99m}Tc-sestamibi (MPS). They were evaluated for body mass index, metabolic control of DM, type of therapy, systemic arterial hypertension, dyslipidemia, nephropathy, retinopathy, peripheral neuropathy, smoking, and familial history of CAD. Results: MPS was abnormal in 15 patients (25.4%): 12 (20.3%) with perfusion abnormalities, and 3 with isolated left ventricular dysfunction. The strongest predictors for abnormal myocardial perfusion were: age 60 years and above (p = 0.017; odds ratio [OR] = 6.0), peripheral neuropathy (p = 0.028; OR = 6.1), nephropathy (p = 0.031; OR = 5.6), and stress ECG positive for ischemia (p = 0.049; OR = 4.08). Conclusion: Silent myocardial ischemia occurs in more than one in five asymptomatic diabetic patients. The strongest predictors of ischemia in this study were: patient age, peripheral neuropathy, nephropathy, retinopathy and a stress ECG positive for ischemia. (author)

  17. Myocardial perfusion scintigraphy in the detection of silent ischemia in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Oki, Glaucia Celeste Rossatto; Pavin, Elizabeth Joao; Parisi, Maria Candida R.; Coelho, Otavio Rizzi; Almeida, Raitany C.; Etchebehere, Elba Cristina Sa de Camargo; Ramos, Celso Dario; Camargo, Edwaldo Eduardo

    2013-01-01

    Objective: This study was aimed to evaluate myocardial perfusion in asymptomatic patients with type 1 (DM1) and type 2 diabetes mellitus (DM2) without previous diagnoses of coronary artery disease (CAD) or cerebral infarction. Materials and Methods: Fifty-nine consecutive asymptomatic patients (16 DM1, 43 DM2) underwent myocardial perfusion scintigraphy with 99m Tc-sestamibi (MPS). They were evaluated for body mass index, metabolic control of DM, type of therapy, systemic arterial hypertension, dyslipidemia, nephropathy, retinopathy, peripheral neuropathy, smoking, and familial history of CAD. Results: MPS was abnormal in 15 patients (25.4%): 12 (20.3%) with perfusion abnormalities, and 3 with isolated left ventricular dysfunction. The strongest predictors for abnormal myocardial perfusion were: age 60 years and above (p = 0.017; odds ratio [OR] = 6.0), peripheral neuropathy (p = 0.028; OR = 6.1), nephropathy (p = 0.031; OR = 5.6), and stress ECG positive for ischemia (p = 0.049; OR = 4.08). Conclusion: Silent myocardial ischemia occurs in more than one in five asymptomatic diabetic patients. The strongest predictors of ischemia in this study were: patient age, peripheral neuropathy, nephropathy, retinopathy and a stress ECG positive for ischemia. (author)

  18. Clinical evaluation of scintigraphy for malignant tumors in children

    International Nuclear Information System (INIS)

    Ishii, Katsumi; Aso, Koichi; Yamada, Nobuaki; Horiike, Shigeharu; Matsubayashi, Takashi

    1982-01-01

    X-ray study, Computed tomography, Echography and Scintigraphy are chosen to draw visual images of malignant tumors in children. To obtain higher diagnostic sensitivity, we recommend that 67-Ga-scintigraphy and other different scitigraphy for organs are performed on each child suspected of having malignant tumor. 67-Ga does not have accurate sensitivity for neuroblastoma, but bone scintigraphy with 99m-Tc-labelled phosphate complexes detects neuroblastoma as a positive image. 67-Ga scintigraphy and other different radiopharmaceutical scintigraphy should be used for primary visualization and control of malignant tumor in children. Serial scintigraphy at proper intervals are very effective to detect local recurrence and metastasis of malignant tumors. (author)

  19. Stress thallium-201 myocardial scintigraphy for the detection of individual coronary arterial lesions in patients with and without previous myocardial infarction

    International Nuclear Information System (INIS)

    Rigo, P.; Bailey, I.K.; Griffith, L.S.; Pitt, B.; Wagner, H.N. Jr.; Becker, L.C.

    1981-01-01

    The value of stress thallium-201 scintigraphy for detecting individual coronary arterial stenoses was analyzed in 141 patients with angiographically proved coronary artery disease, 101 with and 40 without a previous myocardial infarction. In patients without infarction, the sensitivity for detecting greater than 50 percent narrowing in the left anterior descending, the right and the left circumflex coronary artery was 66, 53 and 24 percent, respectively. In those with a previous infarction, the sensitivity for demonstrating disease in the artery corresponding to the site of infarction was 100 percent for the left anterior descending, 79 percent for the right and 63 percent for the left circumflex coronary artery. In patients with a prior anterior infarction, concomitant right or left circumflex coronary arterial lesions were detected in only 1 of 12 cases, whereas in those with previous inferior or inferolateral infarction, the sensitivity for left anterior descending coronary artery disease was 69 percent. Because of the reasonably high sensitivity for detecting left anterior descending arterial disease, irrespective of the presence and location of previous infarction, myocardial scintigraphy was useful in identifying multivessel disease in patients with a previous inferior infarction. However, because of its relative insensitivity for right or left circumflex coronary artery disease, scintigraphy proved to be a poor predictor of multivessel disease in patients with a prior anterior infarction and in patients without previous myocardial infarction

  20. Influence of hypertensive left ventricular hypertrophy on detection of ischemic area with exercise thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Toyama, Takuji; Nishimura, Tsunehiko; Uehara, Toshiisa

    1992-01-01

    Sixty-four patients with single left anterior descending artery disease having effort angina (group A: 40 patients with hypertrophic hypertension, group B: 10 patients with hypertrophic hypertension, group C: 14 patients with non-hypertrophic hypertension) were assessed to determine the influence of hypertensive left ventricular (LV) hypertrophy on detection of ischemic area. The criterion of hypertrophy by two-dimensional echocardiography was >12 mm in the wall thickness of interventricular septal or posterior wall. Population in Group B might show low detectability in ischemic area by 201 Tl myocardial scintigraphy (positive thallium rate 60%, defect score 2.7±3.6), and high lung thallium uptake and high frequence of ECG positive among three groups. In semiquantitative analysis, the washout rate of the posterolateral wall and %RD (delayed %uptake-initial %uptake) of the septal wall in patients with Group B were lowest among three groups. However, the washout rate in the septal wall against the posterior wall, and the initial %uptake and the delayed %uptake of the septal wall were not significantly different among three groups. We could conclude that the decreased washout rate in nonischemic area with hypertensive LV hypertrophy might make the ischemic area masked. (author)

  1. Thyroid autonomy: sensitive detection in vivo and estimation of its functional relevance using quantified high-resolution scintigraphy

    International Nuclear Information System (INIS)

    Baehre, M.; Lindemann, C.; Emrich, D.; Hilgers, R.

    1988-01-01

    This study is concerned with 236 euthyroid individuals living in an area of iodine deficiency, 227 of whom had endemic goitres. In these subjects, autonomy could be suspected owing to an inhomogeneous activity distribution on the thyroid scintigram or a subnormal TSH response to TRH. They complete a total number of 426 investigated individuals. Previously, in 190 separated controls without evidence of autonomy, the reference ranges for the thyroid 99m Tc pertechnetate uptake under suppression (TcU s ), a measure for the non-suppressible thyroid iodide clearance, and for suppressibility of circumscribed thyroid regions, had been determined. These two parameters obtained by highresolution quantified scintigraphy were used for an accurate detection of thyroid autonomy among the 236 individuals. Suppression scintigraphy revealed autonomy in 171 patients. ΔTSH after TRH was subnormal in 40% of the subjects with abnormal thyroid suppressibility. Prevalence of abnormal suppression was dependent on three factors: patient age, goitre type and estimated thyroid weight. In the total investigated collective, the prevalence of autonomy was 77% in patients with a goitre weight above 50 g. The individuals with abnormal suppression were grouped into four classes of TcU s . I these classes, free thyroxie index (FT 4 I) and total triiodothyronine (TT 3 ) icreased with increasing TcU s , whereas ΔTSH decreased. This finding indicates a continuum of different extents of autonomous thyroid function, whereas in the individual patient, the extent can be determined using the pertechnetate uptake under suppression. In addition, FT 4 I, TT 3 and ΔTSH in each of the TcU s classes depended on the individual iodine supply. It is concluded that, in patients with thyroid autonomy, actual thyroid hormone concentrations and TSH stimulation are determined by two major factors: the extent of autonomy and the individual iodine supply. Therefore, in iodine deficiency, the TRH test may be normal

  2. The usefulness of bone and bone-marrow scintigraphy in the detection of bone involvement in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Sone, Teruki

    1986-01-01

    We used a combination of bone and bone-marrow scintigraphy to evaluate bone involvement in 15 patients with multiple myeloma (7 in untreated group and 8 in chemotherapy group). Of the 3 cases in untreated group whose 99m Tc-methylene diphosphonate (MDP) bone scans showed no abnormality, one had abnormal 99m Tc-suffer colloid bone-marrow scintigraphy. In other 4 cases of untreated group whose bone scan showed cold defects, bone-marrow scintigraphy delineated clearly the areas of tumor-cell invasion. On the other hand, in all chemotherapy cases, multiple hot spots were observed on bone scintigram, but on bone-marrow scintigram abnormalities were not recognized. In conclusion, the combination scintigraphy of bone and bone-marrow was a useful method in evluating bone involvement in patients with multiple myeloma. (author)

  3. Fever of unknown origin; Re-evaluation of sup 67 Ga scintigraphy in detecting causes of fever

    Energy Technology Data Exchange (ETDEWEB)

    Misaki, Takashi; Matsui, Akira; Tanaka, Fumiko; Okuno, Yoshishige; Mitsumori, Michihide; Torizuka, Tatsurou; Dokoh, Shigeharu; Hayakawa, Katsumi; Shimbo, Shin-ichirou (Kyoto City Hospital (Japan))

    1990-06-01

    Gallium-67 scintigraphy is a commonly performed imaging modality in deteting pyrogenic lesions in cases of long-standing inexplainable fever. To re-evaluate the significance of gallium imaging in such cases, a retrospective review was made of 56 scans performed in febrile patients in whom sufficient clinical and laboratory findings were obtained. Gallium scans were true positive in 30 patients, false positive in 3, true negative in 19, and false negative in 4. In the group of true positive, local inflammatory lesions were detected in 23 patients with a final diagnosis of lung tuberculosis, urinary tract infection, and inflammatory joint disease. Abnormal gallium accumulation, as shown in the other 7 patients, provided clues to the diagnosis of generalized disorders, such as hematological malignancies (n=3), systemic autoimmune diseases (n=3), and severe infectious mononucleosis (n=one). In the group of false positive, gallium imaging revealed intestinal excretion of gallium in 2 patients and physiological pulmonary hilar accumulation in one. In the true negative group of 19 patients, fever of unknown origin was resolved spontaneously in 12 patients, and with antibiotics and corticosteroids in 2 and 5 patients, respectively. Four patients having false negative scans were finally diagnosed as having urinary tract infection (n=2), bacterial meningitis (n=one), and polyarteritis (n=one). Gallium imaging would remain the technique of choice in searching for origin of unknown fever. It may also be useful for early diagnosis of systemic disease, as well as focal inflammation. (N.K.).

  4. Hepatobiliary scintigraphy

    International Nuclear Information System (INIS)

    Velchik, M.G.

    1988-01-01

    This chapter describes the role of nuclear medicine in the evaluation of the hepatobiliary system. The technical aspects of hepatobiliary scintigraphy, or cholescintigraphy (radiopharmaceutical, radiation dosimetry, instrumentation, and method) are briefly presented, followed by a discussion of each of the indications for such examination. Its relative advantages and disadvantages with respect to alternative radiographic examinations are emphasized. Logical, efficient, cost-effective sequences of diagnostic studies are recommended whenever appropriate in order to derive the maximum information with the least time and expense. It is hoped that the reader will come away with an appreciation of the type of diagnostic information provided by hepatobiliary scintigraphy, its accuracy, its application in the workup of the patient with hepatobiliary disease, and its strengths and limitations compared with other radiologic studies

  5. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  6. Scintigraphy of spinal disorders in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Mandell, G.A. (Dept. of Medical Imaging, Alfred I. duPont Inst., Wilmington, DE (United States)); Harcke, H.T. (Dept. of Medical Imaging, Alfred I. duPont Inst., Wilmington, DE (United States))

    1993-08-01

    Bone scintigraphy in adolescents is useful in helping to differentiate between developmental (atypical lumbar Scheuermann disease), infectious (discitis, osteomyelitis), neoplastic (osteoid osteoma, osteoblastoma), and traumatic (occult fractures, spondylolysis, pseudoarthrosis) disease of the spine. Double-phase (blood pool, delayed images) scintigraphy can characterize the pattern (i.e., linear in fracture, ovoid in nidus of osteoid osteoma). Single-photon emission computed tomography (SPECT) can be helpful in detecting the subtle presence of stress reaction (spondylolyses) not noted on routine planar scintigraphy and radiography. Bone scintigraphy is most beneficial when correlated with other imaging modalities in refining the diagnosis of spinal diseases. (orig.)

  7. Scintigraphy of spinal disorders in adolescents

    International Nuclear Information System (INIS)

    Mandell, G.A.; Harcke, H.T.

    1993-01-01

    Bone scintigraphy in adolescents is useful in helping to differentiate between developmental (atypical lumbar Scheuermann disease), infectious (discitis, osteomyelitis), neoplastic (osteoid osteoma, osteoblastoma), and traumatic (occult fractures, spondylolysis, pseudoarthrosis) disease of the spine. Double-phase (blood pool, delayed images) scintigraphy can characterize the pattern (i.e., linear in fracture, ovoid in nidus of osteoid osteoma). Single-photon emission computed tomography (SPECT) can be helpful in detecting the subtle presence of stress reaction (spondylolyses) not noted on routine planar scintigraphy and radiography. Bone scintigraphy is most beneficial when correlated with other imaging modalities in refining the diagnosis of spinal diseases. (orig.)

  8. Liver scintigraphy

    International Nuclear Information System (INIS)

    Tateno, Yukio

    1996-01-01

    Liver scintigraphy can be classified into 3 major categories according to the properties of the radiopharmaceuticals used, i.e., methods using radiopharmaceuticals which are (1) incorporated by hepatocytes, (2) taken up by reticulo endothelial cells, and (3) distributed in the blood pool of the liver. Of these three categories, the liver scintigraphy of the present research falls into category 2. Radiopharmaceuticals which are taken up by endothelial cells include 198 Au colloids and 99m Tc-labelled colloids. Liver scintigraphy takes advantage of the property by which colloidal microparticles are phagocytosed by Kupffer cells, and reflect the distribution of endothelial cells and the intensity of their phagocytic capacity. This examination is indicated in the following situations: (i) when you suspect a localized intrahepatic lesion (tumour, abscess, cyst, etc.), (ii) when you want to follow the course of therapy of a localized lesion, (iii) when you suspect liver cirrhosis, (iv) when you want to know the severity of liver cirrhosis or hepatitis, (v) when there is hepatomegaly and you want to determine the morphology of the liver, (vi) differential diagnosis of upper abdominal masses, and (vii) when there are abnormalities of the right diaphragm and you want to know their relation to the liver

  9. Successful application of technetium-99m-labeled octreotide acetate scintigraphy in the detection of ectopic adrenocorticotropin-producing bronchial carcinoid lung tumor: a case report

    Directory of Open Access Journals (Sweden)

    Fallahi Babak

    2010-10-01

    Full Text Available Abstract Introduction The diagnostic efficacy of somatostatin receptor scintigraphy labeling with 111 indium in the localization of tumors has been assessed in a limited number of patients with contradictory outcomes. Here, we describe the case of a patient with an ectopic adrenocorticotropic hormone-producing bronchial carcinoid tumor diagnosed preoperatively using technetium-99m-labeled octreotide acetate scintigraphy. Case presentation A 29-year-old Asian man presented to our hospital with the typical clinical features of Cushing's syndrome, which he had had for a duration of 18 months. The results of a biochemical evaluation revealed he had adrenocorticotropic hormone-dependent Cushing's syndrome. The results of a spiral abdominal computed tomography scan showed he had bilateral adrenal hypertrophy. A magnetic resonance image of the patient's brain showed he had a normal hypophysis. Whole body technetium-99m-labeled octreotide acetate scintigraphy was performed to check for the presence of an ectopic adrenocorticotropic hormone-producing tumor. The scan results showed a small focal increase in uptake in the lower lobe of our patient's right lung, just above his diaphragm. A spiral chest computed tomography scan also revealed a small non-specific lesion in the same region. A transthoracic biopsy was then performed. Pathological evaluation confirmed the diagnosis of a carcinoid tumor, of the adrenocorticotropic hormone-producing type. After surgical removal, the patient's symptoms resolved and significant clinical improvement was achieved. Conclusions This case report shows that technetium-99m-labeled octreotide acetate scintigraphy can effectively detect an ectopic adrenocorticotropic hormone-producing bronchial carcinoid.

  10. Correlation of immunosuppression scheme with renal graft complications detected by dynamic renal scintigraphy; Correlacao do esquema de imunossupressao com complicacoes pos-operatorias de transplantes renais atraves do uso da cintilografia renal dinamica

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Flavia Paiva Proenca [Universidade do Rio de Janeiro (UNIRIO), RJ (Brazil). Inst. Biomedico; Goncalves, Renato Teixeira [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Unidade de Transplante Renal; Fonseca, Lea Miriam Barbosa da [Universidade Federal, Rio de Janeiro, RJ (Brazil); Gutfilen, Bianca [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Centro Biomedico]. E-mail: audiocompany@unikey.com.br

    2001-10-01

    Dynamic renal scintigraphy allows the diagnosis of complications in patients submitted to organ transplantation, such as perfusion abnormalities, acute tubular necrosis and rejection. In this study we employed {sup 99m} Tc-DTPA scintigraphy to study patients submitted to kidney transplantation. The results obtained and the clinical findings were conjunctively analyzed in order to detect graft rejection or other complications. The type of immunosuppressive scheme used was also correlated with the observed complications. Fifty-five patients submitted to kidney transplantation from 1989 to 1999 were evaluated. All patients with nephrotoxicity received a 3-drug immunosuppressive scheme. In this study, acute rejection was the most frequent complication (40.4%) observed following transplantation. Thirteen of 15 recipients of cadaveric kidney grafts presented acute tubular necrosis. Only one false-positive case was observed when scintigraphy and clinical findings were not concordant. We suggest carrying out renal scintigraphy to follow-up post-transplantation patients. (author)

  11. Diagnostic accuracy of bone metastases detection in cancer patients. Comparison between bone scintigraphy and whole-body FDG-PET

    International Nuclear Information System (INIS)

    Fujimoto, Ryota; Higashi, Tatsuya; Nakamoto, Yuji

    2006-01-01

    18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) has become widely available and an important oncological technique. To evaluate the influence of PET on detection of bone metastasis, we compared the diagnostic accuracy of PET and conventional bone scintigraphy (BS) in a variety of cancer patients. Consecutive ninety-five patients with various cancers, who received both PET and BS within one month, were retrospectively analyzed. A whole-body PET (from face to upper thigh) and a standard whole body BS were performed and these images were interpreted by two experienced nuclear medicine physicians with and without patient information using monitor diagnosis. Each image interpretation was performed according to 8 separate areas (skull, vertebra, upper limbs, sternum and clavicles, scapula, ribs, pelvis, and lower limbs) using a 5-point-scale (0: definitely negative, 1: probably negative, 2: equivocal, 3: probably positive, 4: definitely positive for bone metastasis). Twenty-one of 95 patients (22.1%) with 43 of 760 areas (5.7%) of bone metastases were finally confirmed. In untreated patients, 12 of 14 bone metastasis positive patients were detected by PET, while 9 of 14 were detected by BS. Three cases showed true positive in PET and false negative in BS due to osteolytic type bone metastases. In untreated cases, PET with and without clinical information showed better sensitivity than BS in patient-based diagnosis. For the purpose of treatment effect evaluation, PET showed better results because of its ability in the evaluation of rapid response of tumor cells to chemotherapy. Out of 10 cases of multiple-area metastases, 9 cases included vertebrae. There was only one solitary lesion located outside of field of view (FOV) of PET scan in the femur, but with clinical information that was no problem for PET diagnosis. Diagnostic accuracy of bone metastasis was comparable in PET and BS in the present study. In a usual clinical condition, limited FOV (from

  12. Sensitivity and accuracy of thallium-201 myocardial scintigraphy in the detection of coronary artery and myocardial disease

    International Nuclear Information System (INIS)

    Loesse, B.; Kroenert, H.; Rafflenbeul, D.; Feinendegen, L.E.; Loogen, F.; Duesseldorf Univ.

    1979-01-01

    169 patients (154 men, 15 women, mean age 49.5 years, range 27 to 64 years) were studied by means of 201-Thallium myocardial scintigraphy (201-Tl) and coronary angiography. According to the coronarangiogram, 130 patients had coronary artery disease (CAD): 53 a 1-vessel CAD, 29 a 2-vessel CAD, 48 a 3-vessel CAD. 39 patients had normal or less than 50% stenosed coronary arteries, but only 13 of these patients had also a normal ventriculogram, whereas 26 had an abnormal ventriculogram with local hypo-, a- or dyskinesia, diffuse hypokinesia, dilatation, or marked hypertrophy. The ramus interventicularis anterior (RIVA) was involved (stenosis of more than 50%) in 117 cases, the ramus circumflexus (R. circ.) in 70 cases, and the right coronary artery (RCA) in 67 cases. 201-Tl was abnormal in 98% of all 130 patients with CAD, in 100% of 93 patients with prior infarction, and in 95% of 37 patients without prior infarction. The sensitivity of the rest and/or exercise ECG in the same patients was only 79%, 88% and 57%, respectively. 201-Tl was abnormal in all 26 patients with a pathologic ventriculogram in spite of normal coronary arteries. 201-Tl and ECG were normal in only 9 of the 13 patients (=69%) with normal coronary arteries and normal ventriculogram. Myocardial biopsy, however, performed in 2 of the other 4 patients disclosed in part severe degenerative changes which can possibly explain the abnormal findings of 201-Tl and ECG. Significantly, i.e. more than 50% stenosed RIVA was correctly detected by 201-Tl in 98%, R. circ. in 71%, and RCA in 91% of the cases. The specificity of 201-Tl was limited by the great number of patients with a pathologic ventriculogram combined with normal coronary arteries. (orig.) [de

  13. 99m-Tc tetrofosmin scintigraphy vs mammography in breast cancer detection

    International Nuclear Information System (INIS)

    Jaukovic, L.J.; Spaic, R.; Markovic, S.; Stankovic, N.; Dimitrijevic, S.; Strbac, M.

    2002-01-01

    99m-Tc tetrofosmin is a widely used radiotracer for breast cancer imaging. Routine mammography ,as a method for screening breast cancer patients, might be insufficient for diagnosis, especially in patients with dense breast. Aim: The aim of this study was to compare the results of mammography (MM) and scintimammography with 99m- Tc tetrofosmin (SMM) in detection of primary breast cancer. Method: Thirty patients with breast disease were included in study. All of them had clinical investigation, MM, SMM and surgical biopsy for final histological diagnosis. An amount of 600 MBq 99m- Tc tetrofosmin was injected intravenously in the arm opposite to the side of breast lesion. Ten minutes after injection planar breast 7-minutes scans were performed in supine (anterior) and prone (left and right lateral) position. Results: Out of 30 lesion breast cancer was histologically confirmed in 20 (15 ductal invasive, two lobular, one colloid, one papillar carcinoma and one case of cyst sarcoma phylodes- malignant type.) For MM sensitivity of 80%, specificity of 60% and accuracy of 76 % were obtained. At SMM 19/ 20 malignant lesions were detected. Only one false negative result was obtained in 1.0 cm lobular infiltrative cancer, although the smallest detectable lesion measured 0.6 cm. At pathohistology ten lesions presented benign. Four false positive results (two fibroadenomas, one lipogranuloma and one case of fibrocystic disease) were observed, six true negative results in four cases with fibrocystic disease and two fibroadenomas. The overall sensitivity of scintimammography was 95%, specificity 60% and accuracy 83%. Conclusion: We concluded that sensitivity of 99m-Tc tetrofosmin scintimammography in detection of breast cancer is superior to that of mammography. Our results suggest that 99m -Tc tetrofosmin is a suitable tumor seeking agent for breast cancer imaging

  14. Detection of degenerative disease of the temporomandibular joint by bone scintigraphy: concise communication

    International Nuclear Information System (INIS)

    Goldstein, H.A.; Bloom, C.Y.

    1980-01-01

    Nine patients with facial pain were evaluated with limited bone scans. The scintigrams correlated with microscopy in all patients, although radiographs correlated with microscopy in only five patients. The degenerative disease process in the temporomandibular joint was more extensive in the patients with radiographic and scintigraphic abnormalities than in those with scintigraphic abnormalities alone. The limited bone scan appears useful in detecting early degenerative changes in the temporomandibular joint

  15. Myocardial scintigraphy using a fatty acid analogue detects coronary artery disease in hemodialysis patients.

    Science.gov (United States)

    Nishimura, Masato; Hashimoto, Tetsuya; Kobayashi, Hiroyuki; Fukuda, Toyofumi; Okino, Koji; Yamamoto, Noriyuki; Fujita, Hiroshi; Inoue Tsunehiko Nishimura, Naoto; Ono, Toshihiko

    2004-08-01

    Coronary artery disease contributes significantly to mortality in end-stage renal disease (ESRD) patients. Single-photon emission computed tomography (SPECT) using an iodinated fatty acid analogue, iodine-123-methyl iodophenylpentadecanoic acid (123I-BMIPP), can assess fatty acid metabolism in the myocardium. We investigated the ability of 123I-BMIPP SPECT to detect coronary artery disease in hemodialysis patients compared with 201thallium chloride (201Tl) SPECT. We prospectively studied 130 ESRD patients undergoing hemodialysis for a mean of 88.6 months (male/female, 77/53; mean age, 63.8 years). Dual SPECT using 123I-BMIPP and 201Tl was performed, followed by coronary angiography. SPECT findings were graded in 17 segments on a five-point scale (0, normal uptake; 4, none) and assessed as a summed score. By coronary angiography, 71.5% of patients (93/130) had significant coronary stenosis (> or =75%), and five patients showed coronary spasm without coronary stenosis. When a BMIPP summed score of 6 or more was defined as abnormal, sensitivity, specificity, and accuracy for detecting coronary artery disease by BMIPP SPECT were 98.0%, 65.6%, and 90.0%, respectively; in contrast, these parameters for detecting coronary artery disease by Tl SPECT were 84.7%, 46.9%, and 75.0%, respectively, when a Tl summed score of 1 or more was defined as abnormal. In receiver operating characteristic analysis, the area under the curve was 0.895 in BMIPP and 0.727 in Tl SPECT, respectively. Resting BMIPP SPECT is superior to Tl SPECT for detecting coronary lesions, and provides safe screening for coronary artery disease among maintenance hemodialysis patients.

  16. The impact of different imaging modalities of 67Ga scintigraphy on the image quality and the ability in detection of lesions

    International Nuclear Information System (INIS)

    Liu Xiuqin; Li Wenchan; Zhang Jianfei; Yao Zhiming

    2009-01-01

    Objective: 67 Ga scintigraphy is an important method in detection of active sarcoidosis. The aim of this research was to study the influence of planar and tomography. with and without CT attenuation correction (AC and NAC), on 67 Ga images on the image quality and the ability in detection of lesions. Methods: Thirty one patients (13 male, 18 female, age range: 33-87 years)with sarcoidosis underwent 67 Ga planar and tomographic scans. AC and NAC.The imaging quality and the ability in detection of hyper-radioactive lymph nodes in lung hilar and mediastinal(1esion) among the planar, AC and NAC images were compared. The paired t-test and χ 2 -test were used for data analysis with SPSS 10.0 software. Results: From planar, NAC to AC, the image quality was better and better in proper order (χ 2 = 25.88, P 67 Ga tomographic scintigraphy can impmve the ability in detection of hyperradioactive lung hilar and mediastinal lymph nodes compared with planar image does. CT AC for 67 Ga tomography can improve the tomographic imaging quality. (authors)

  17. Are oblique views necessary for detecting space occupying lesions in liver scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Seki, Hiroyasu; Taki, Junichi; Yokoyama, Kunihiko; Tada, Akira

    1983-01-01

    In colloid scanning of the liver to determine the presence or absence of SOL(s), it has been suggested that oblique views are desirable. However, it is not popular in Japan to obtain oblique views in routine liver imgaing. The present study was conducted to determine whether such additional views are necessary or not. Liver images of 20 patients with SOL(s) and 84 patients without SOL, all of which were confirmed by ultrasonography, transmission computed tomography and/or clinical course, were evaluated initially using 4 standard views and then adding oblique views by 6 physicians (3 experts and 3 freshmen in nuclear medicine). The numbers of cases showing different interpretation between 4 views and 6 views were 15, 10 and 13 each when interpreted by 3 experts. However, those were 21, 33 and 18 each when interpreted by 3 freshmen. Sensitivity for detecting SOL was improved in 3 physicians by adding oblique views, but was the same in other 3. Specificity was improved in only one physicinan. Overall accuracy was consequently improved in 4 physicians and was deteriorated in 2 physicians. ROC analysis revealed that in the freshman group more accurate interpretation was attained by using 6 views, but in the expert group false-positive cases were increased by using 6 views. Some cases showing usefulness for detecting SOL were presented. In conclusion, oblique views gave more accurate interpretation in inexpertienced observers, and useful information in some cases. (author)

  18. Sensitivity of thallium scintigraphy in the detection of individual coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Wiqar, M.A.; Khan, Z.A.; Ahmad, S.A.

    1988-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormals i.e. showing triple, double and single vessel disease. Out of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males and their ages ranged between 34-54 years. Fifteen patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the fast. We analysed their coronary angiograms and compared them with the scintigraphic findings. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% circumflex lesions. Thallium scan sometimes fails to identify the less serve lesions in presence of more severe coronary lesions in the some patients. The sensitivity is much higher in single vessel coronary artery disease. (author)

  19. The value and limitation thallium scintigraphy in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Amin, W.; Khan, Z.A.; Ahmed, S.A.

    1986-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormal i.e. showing triple, double and single vessel disease out of a pool of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males, their ages ranged between 34-54 years. Resting ECG's were normal in 25 patients, 15 patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the past. Coronary angiography revealed triple vessel disease in 20 patients, double vessel disease in 15, and single vessel coronary artery disease in 10. We analysed their coronary angiograms and compared them with the scintigraphic finding. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% of circumflex lesions. The sensitivity is much higher in single vessel coronary artery disease. (author)

  20. {sup 99m}Tc-MIBI scintigraphy for early detection of locally recurrent non-small cell lung cancer treated with definitive radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Masaya; Nozaki, Miwako; Kawashima, Miho; Iimuro, Mamoru; Kitazumi, Yoshinori; Okayama, Aya; Natsui, Satoshi [Department of Radiology, Koshigaya Hospital, Dokkyo University School of Medicine, 2-1-50 Minami-Koshigaya, 343-8555, Koshigaya (Japan); Hamashima, Yoshio; Nagao, Koushuu [Department of Respiratory Internal Medicine, Koshigaya Hospital, Dokkyo University School of Medicine, Koshigaya (Japan)

    2003-07-01

    After radiation therapy of lung cancer, a dense fibrotic shadow develops in the irradiated lung. Owing to this fibrosis, early detection of local recurrence after treatment is sometimes difficult even when using computed tomography (CT) and magnetic resonance imaging. We investigated the diagnostic accuracy of technetium-99m hexakis 2-methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy for the detection of recurrent lung cancer following definitive radiation therapy. Eighteen patients with primary non-small cell lung cancer treated with radiation therapy 1 year previously were studied with {sup 99m}Tc-MIBI scintigraphy. They showed no evidence of local recurrence on serial chest radiographs. All single-photon emission tomography (SPET) images acquired 2 h after intravenous administration of the radiopharmaceutical were visually interpreted with knowledge of the pretreatment chest radiograph, CT and the details of radiation therapy (radiation portals and administered doses). A region of interest (ROI) analysis was also performed. In addition to the ROI ratio of tumour uptake to accumulation in contralateral normal lung (tumour/lung ratio), another semiquantitative analysis, the ratio of tumour uptake to accumulation in radiation fibrosis (tumour/fibrosis ratio), was performed to differentiate between accumulation in radiation fibrosis and the tumour uptake. The scintigraphic diagnoses were correlated with clinical outcome. The sensitivity, specificity and negative predictive value of {sup 99m}Tc-MIBI scintigraphy for the detection of recurrent lung cancer were all 88.9% (8/9). The tumour/lung ratios (mean{+-}SEM) of the nine patients with local recurrence and the other eight without local failure were 2.00{+-}0.11 and 1.40{+-}0.09, respectively (P<0.01). The tumour/fibrosis ratios of the patients with and those without recurrence were 1.47{+-}0.08 and 0.93{+-}0.05, respectively (P<0.01). These results suggest that {sup 99m}Tc-MIBI scintigraphy might be of

  1. Impaired detection of happy facial expressions in autism.

    Science.gov (United States)

    Sato, Wataru; Sawada, Reiko; Uono, Shota; Yoshimura, Sayaka; Kochiyama, Takanori; Kubota, Yasutaka; Sakihama, Morimitsu; Toichi, Motomi

    2017-10-17

    The detection of emotional facial expressions plays an indispensable role in social interaction. Psychological studies have shown that typically developing (TD) individuals more rapidly detect emotional expressions than neutral expressions. However, it remains unclear whether individuals with autistic phenotypes, such as autism spectrum disorder (ASD) and high levels of autistic traits (ATs), are impaired in this ability. We examined this by comparing TD and ASD individuals in Experiment 1 and individuals with low and high ATs in Experiment 2 using the visual search paradigm. Participants detected normal facial expressions of anger and happiness and their anti-expressions within crowds of neutral expressions. In Experiment 1, reaction times were shorter for normal angry expressions than for anti-expressions in both TD and ASD groups. This was also the case for normal happy expressions vs. anti-expressions in the TD group but not in the ASD group. Similarly, in Experiment 2, the detection of normal vs. anti-expressions was faster for angry expressions in both groups and for happy expressions in the low, but not high, ATs group. These results suggest that the detection of happy facial expressions is impaired in individuals with ASD and high ATs, which may contribute to their difficulty in creating and maintaining affiliative social relationships.

  2. Giant tumor thrombus in the right atrium clearly detected by /sup 111/In-oxine labeled platelet scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, T; Ishikawa, N; Satoh, A; Masuda, Y; Hiramatsu, Y; Akisada, M; Sakakibara, Y

    1985-07-01

    A 54-year-old man was admitted to hospital with a 3-month history of progressive dyspnea with coughing. A giant right atrial mass, originating from a hepatocellular carcinoma, was visualized by computed tomography, and digital subtraction angiography. The volume if the right atrial mass was increasing rapidly. It was therefore essential to determine whether this giant mass was a tumor thrombus or a multiplication of the hepatocellular carcinoma. /sup 111/In-oxine labeled platelet scintigraphy revealed active accumulation in the right atrium caused by the presence of active platelet deposition, and slight accumulation in the lung fields probably due to embolic showers originating from the tumor thrombus in the right atrium. This is the first case report showing that /sup 111/In-oxine labeled platelet scintigraphy can aid in confirming the nature of a giant tumor thrombus in the right atrium and can clarify the pathogenesis of the respiratory symptoms.

  3. Preoperative computed tomography and scintigraphy to facilitate the detection of accessory spleen in patients with hematologic disorders

    International Nuclear Information System (INIS)

    Koyanagi, Nobuhiro; Kanematsu, Takashi; Sugimachi, Keizo

    1988-01-01

    Accessory spleens of 1.5 cm in size were preoperatively identified by the combined use of computerized tomography and splenic scintigraphy in two patients with hematologic diseases. After the accessory spleen had been removed from the first patient, who had persistent hereditary spherocytosis and had undergone a splenectomy 15 months before, a postoperative decrease in hyperbilirubinemia was noted. In the other patient who had idiopathic thrombocytopenic purpura, a successful accessory splenectomy was done at the same time as her splenectomy, and was followed by 6 months' complete remission. These events indicate that preoperative investigations using computerized tomography and scintigraphy are indispensable for ruling out an accessory spleen in those patients for whom splenectomy needs to be done in order to alleviate hematologic disorders. (author)

  4. F-18 Sodium Fluoride Positron Emission Tomography/Computed Tomography for Detection of Thyroid Cancer Bone Metastasis Compared with Bone Scintigraphy.

    Science.gov (United States)

    Lee, Hyunjong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun

    2016-01-01

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  5. F-8 sodium fluoride position emission tomography/computed tomography for detection of thyroid cancer bone metastasis compared with bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Jong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p < 0.025). The specificity (4/7 = 57.1%) of bone PET/CT was not significantly different from that of BS (5/7 = 71.4%, p > 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  6. 111In-oxine labelled leukocyte scintigraphy in the detection and localization of active inflammation and sepsis

    International Nuclear Information System (INIS)

    Kelly, M.J.; Kalff, V.; Hicks, R.J.; Spicer, W.J.; Spelman, D.W.

    1990-01-01

    Indium-111-oxine labelled leukocyte scintigraphy is a diagnostic technique which has recently become available for clinic evaluation within Australia. The technique was used to assess patients with suspected sepsis of inflammation after other commonly used investigations had failed to confirm a diagnosis. Four patient subgroups were evaluated: fever of unknown origin suspected abdominal or postoperative sepsis; suspected active inflammatory bowel disease; and suspected sepsis or inflammation of bones or joints. The course of all patients was followed for at least three months to establish the accuracy of the technique. The leukocyte labelling procedure took 90 min and imaging was carried out typically 3-6, 24 and occasionally 48 h after reinjection of the labelled leukocytes. Only in one patient labelling of leukocytes was unsuccessful. In the remaining 99 studies, the overall sensitivity of leukocyte scintigraphy was 88% (36 of 41 patients with a proved inflammatory or infective disease focus had positive scan findings);and the specificity was 95% (55 of 58 cases with no proved disease focus had normal scan findings). These results support the use of this method in nuclear medicine for the evaluation of suspected acute sepsis (symptoms less than four weeks' duration), of inflammatory bowel disease and of suspected infections involving appendicular bones which contain no active bone marrow. It is also a useful secondary scintigraphic procedure, after gallium-67-citrate scintigraphy, in patients with suspected infective disorders of more than four weeks' duration. 27 refs., 2 tabs., 5 figs

  7. The evaluation of the degree of impairment of pulmonary perfusion in lung cancer patients treated by radiotherapy by the quantification of nonuniform distribution of lung perfusion scintigraphy SPECT

    International Nuclear Information System (INIS)

    Mitomo, Osamu; Tsunoda, Takashi; Kuwabara, Hidemasa

    2004-01-01

    By means of quantifying the nonuniform distribution of pulmonary perfusion in Lung Perfusion Scintigraphy SPECT (single photon emission tomography), which is called ''SPECT'' for short, we evaluated the degree of functional impairment of pulmonary perfusion in non-operated lung cancer patients treated by the radiotherapy. Sixty-eight patients with non-operated lung cancer treated with radiotherapy, and who either received or did not receive chemotherapy, from February, 1996 to August, 2002, were examined using SPECT within 6 weeks prior to, or within 2 weeks following radiotherapy. This group was called ''irradiated lung cancer patients''. Twenty-six patients, who were called ''follow-up irradiated lung cancer patients'', were reexamined within four weeks after radiotherapy. On the other hand, 323 patients without lung cancer, who were subdivided into four groups; pulmonary, cardiac, cardio-pulmonary, and non-cardiopulmonary. The SPECT was examined in the supine position after infusing Tc-99m-MAA, 185 MBq in a bolus, mainly into an antecubital vein with the patient's arm elevated. From reconstructed SPECT images, the volume of lung as a whole calculated at 10% of thresholds was assumed to be the ''Baseline Lung Perfusion Volume'' (BPV), and the functional volume rates were calculated in 10% threshold widths from 10% to 100% of the threshold. Assuming the total absolute differences in functional volume rate between each subject and the control to be the distribution index of the lung as a whole (D index), we quantified the degree of nonuniform distribution of the lung as a whole in each subject. In the same way, the distribution index of the left or right lung respectively was calculated as D l or D r index assuming the volume of left or right lung were calculated at 10% of the threshold as left or right BPV and calculating the functional volume rates of each lung in 10% threshold widths from 10% to 100% of the threshold. The D index of irradiated lung cancer

  8. Evaluation of {sup 99m}Tc-UBI 29-41 scintigraphy for specific detection of experimental Staphylococcus aureus prosthetic joint infections

    Energy Technology Data Exchange (ETDEWEB)

    Sarda-Mantel, Laure; Meulemans, Alain; Vrigneaud, Jean-Marc; Raguin, Olivier; Lebtahi, Rachida; Guludec, Dominique Le [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); Service de Medecine Nucleaire, AP-HP, Groupe Hospitalier Bichat-Beaujon, Paris (France); INSERM, U773, Paris (France); Saleh-Mghir, Azzam [Universite Versailles-St-Quentin, EA 3647, Garches (France); Welling, Mick M. [Leiden University Medical Center (LUCM), Department of Radiology, Section of Nuclear Medicine, Leiden (Netherlands); Hervatin, Florence [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); CEA, DSV/DRM/SHFJ, Orsay (France); Martet, Genevieve [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); INSERM, U773, Paris (France); Chau, Francoise [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); Universite Denis Diderot Paris 7, EA 3964, Paris (France)

    2007-08-15

    {sup 99m}Tc-UBI 29-41 (UBI), an antimicrobial peptide, specifically targets bacteria. We tested the ability of UBI to discriminate between infected and uninfected prosthetic joints using a rabbit model previously validated. Left knee arthroplasty was performed on 20 New Zealand rabbits, then 10{sup 7} cfu of S. aureus (n = 12) or sterile saline (n = 8) was injected into the joint. On days 9 and 20 after surgery, planar UBI scintigraphy was performed in six infected and four uninfected rabbits, 1 h and 4 h p.i. (150 MBq), on a gamma camera. Operated-to-normal knee activity ratio (ONKR) was calculated on each scintigram. Then, after sacrifice, tissue samples of both knees were counted in a gamma counter. One rabbit injected with sterile saline had cutaneous infection at sacrifice and was excluded from analysis. ONKR was higher in infected than in uninfected animals 4 h p.i. 20 days after surgery: 1.75 {+-} 0.48 vs 1.13 {+-} 0.11, p = 0.04. From 1 h to 4 h p.i., ONKR increased in 9/12 infected and 0/7 uninfected animals. According to UBI uptake intensity and kinetics, scintigraphy was truly positive in all infected cases on day 9 and in four of six infected cases on day 20. It was truly negative in two of three sterile inflamed prosthetic knees on day 9, and in all cases on day 20. Biodistribution studies revealed increased UBI uptake in periprosthetic tissues in all animals 9 days after surgery, and only in infected animals on day 20. In this experimental study, {sup 99m}Tc-UBI 29-41 scintigraphy permitted the early detection of acute prosthetic joint infection, and exclusion of infection in chronic sterile prosthetic joint inflammation. (orig.)

  9. Evaluation of 99mTc-UBI 29-41 scintigraphy for specific detection of experimental Staphylococcus aureus prosthetic joint infections

    International Nuclear Information System (INIS)

    Sarda-Mantel, Laure; Meulemans, Alain; Vrigneaud, Jean-Marc; Raguin, Olivier; Lebtahi, Rachida; Guludec, Dominique Le; Saleh-Mghir, Azzam; Welling, Mick M.; Hervatin, Florence; Martet, Genevieve; Chau, Francoise

    2007-01-01

    99m Tc-UBI 29-41 (UBI), an antimicrobial peptide, specifically targets bacteria. We tested the ability of UBI to discriminate between infected and uninfected prosthetic joints using a rabbit model previously validated. Left knee arthroplasty was performed on 20 New Zealand rabbits, then 10 7 cfu of S. aureus (n = 12) or sterile saline (n = 8) was injected into the joint. On days 9 and 20 after surgery, planar UBI scintigraphy was performed in six infected and four uninfected rabbits, 1 h and 4 h p.i. (150 MBq), on a gamma camera. Operated-to-normal knee activity ratio (ONKR) was calculated on each scintigram. Then, after sacrifice, tissue samples of both knees were counted in a gamma counter. One rabbit injected with sterile saline had cutaneous infection at sacrifice and was excluded from analysis. ONKR was higher in infected than in uninfected animals 4 h p.i. 20 days after surgery: 1.75 ± 0.48 vs 1.13 ± 0.11, p = 0.04. From 1 h to 4 h p.i., ONKR increased in 9/12 infected and 0/7 uninfected animals. According to UBI uptake intensity and kinetics, scintigraphy was truly positive in all infected cases on day 9 and in four of six infected cases on day 20. It was truly negative in two of three sterile inflamed prosthetic knees on day 9, and in all cases on day 20. Biodistribution studies revealed increased UBI uptake in periprosthetic tissues in all animals 9 days after surgery, and only in infected animals on day 20. In this experimental study, 99m Tc-UBI 29-41 scintigraphy permitted the early detection of acute prosthetic joint infection, and exclusion of infection in chronic sterile prosthetic joint inflammation. (orig.)

  10. Autonomous unobtrusive detection of mild cognitive impairment in older adults.

    Science.gov (United States)

    Akl, Ahmad; Taati, Babak; Mihailidis, Alex

    2015-05-01

    The current diagnosis process of dementia is resulting in a high percentage of cases with delayed detection. To address this problem, in this paper, we explore the feasibility of autonomously detecting mild cognitive impairment (MCI) in the older adult population. We implement a signal processing approach equipped with a machine learning paradigm to process and analyze real-world data acquired using home-based unobtrusive sensing technologies. Using the sensor and clinical data pertaining to 97 subjects, acquired over an average period of three years, a number of measures associated with the subjects' walking speed and general activity in the home were calculated. Different time spans of these measures were used to generate feature vectors to train and test two machine learning algorithms namely support vector machines and random forests. We were able to autonomously detect MCI in older adults with an area under the ROC curve of 0.97 and an area under the precision-recall curve of 0.93 using a time window of 24 weeks. This study is of great significance since it can potentially assist in the early detection of cognitive impairment in older adults.

  11. A rare case of suprahepatic gall bladder with phocomelia and pancytopenia: detected by tc-99m mebrofenin scintigraphy.

    Science.gov (United States)

    Rather, Tanveeer Ah; Khan, Shoukat H; Singh, Manjeet; Choh, Naseer A

    2013-01-01

    The possibility of an ectopic gallbladder should always be considered whenever there is a failure to localize it in its normal anatomical position on routine imaging. Although a very rare entity, the anomalous position of gallbladder can result in misinterpretation of imaging findings and create clinical confusion. Awareness of such an anomaly facilitates proper diagnosis and subsequent management. The authors report a very rare case of suprahepatic gallbladder associated with phocomelia, pancytopenia, and splenomegaly in a young 25-year-old female. The suprahepatic gallbladder was initially visualized on Technetium-99m (Tc-99m) Mebrofenin radionuclide hepatobiliary scintigraphy. Subsequent magnetic resonance cholecystopancreatography (MRCP) was also done to confirm the diagnosis.

  12. A Rare Case of Suprahepatic Gall Bladder with Phocomelia and Pancytopenia: Detected by Tc-99m Mebrofenin Scintigraphy

    International Nuclear Information System (INIS)

    Rather, Tanveeer Ah; Khan, Shoukat H.; Singh, Manjeet; Choh, Naseer A.

    2013-01-01

    The possibility of an ectopic gallbladder should always be considered whenever there is a failure to localize it in its normal anatomical position on routine imaging. Although a very rare entity, the anomalous position of gallbladder can result in misinterpretation of imaging findings and create clinical confusion. Awareness of such an anomaly facilitates proper diagnosis and subsequent management. The authors report a very rare case of suprahepatic gallbladder associated with phocomelia, pancytopenia, and splenomegaly in a young 25-year-old female. The suprahepatic gallbladder was initially visualized on Technetium-99m (Tc-99m) Mebrofenin radionuclide hepatobiliary scintigraphy. Subsequent magnetic resonance cholecystopancreatography (MRCP) was also done to confirm the diagnosis

  13. A comparison of scintigraphy with tumor-seeking radiopharmaceuticals to detect an experimental bone tumors in the rabbits

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Sone, Teruki; Fukunaga, Masao

    2003-01-01

    A comparative study on the accumulation of 99m Tc-phosphorous compound, 99m Tc-hexakis-2-methoxy isobutyl-isonitrile (MIBI), and 99m Tc-tetrofosmin (TF) in the experimental bone tumors using the VX-2 cell was performed. In the group of the femoral metastatic bone tumor, 99m Tc-MIBI showed no accumulation in the femur at 12 days after the transplantation despite the presence of a bone marrow tumor. In the group of the iliac metastatic bone tumor, a bone scintigraphy showed decreased accumulation in the ileum at 16 days, but hot lesions were observed in same sites at 18 days after the transplantation on 99m Tc-MIBI and 99m Tc-TF scintigrams. The tumor to soft tissue accumulation ratio was higher for 99m Tc-MIBI (3.03±1.03) than for 99m Tc-TF (2.55±0.80) (P 99m Tc-MIBI is less satisfactory for the early diagnosis of tumors than bone scintigraphy, and a combined study with both 99m Tc-phosphorous compounds and 99m Tc-MIBI is useful for the evaluation and diagnosis of lesions. (author)

  14. Adrenal scintigraphy using 131I-Adosterol

    International Nuclear Information System (INIS)

    Fukunaga, Masao; Dokoh, Shigeharu; Yamamoto, Itsuo; Morita, Rikushi; Torizuka, Kanji

    1977-01-01

    131 I-Adosterol (6β-iodomethyl-19-norcholest-5(10)-3β-ol) was administered to evaluate adrenal grand in 20 patients including 9 patients with primary aldosteronism, 5 with Cushing's syndrome, one with pheochromocytoma, one with retroperitoneal tumor, 3 with essential hypertension and one with obesity. Standard scintigraphies were performed at 3rd day and again 6th day after administration of 131 I-adosterol (1-1.5 mCi). Suppression scintigraphies were obtained while the patients were taking dexamethasone 2 to 3 mg daily from 3 days prior to injection of the tracer until adrenal imaging. In the cases with essential hypertension and obesity, both adrenal glands were delineated equally by standard scintigraphy, and in one patient, undergone suppression scintigraphy, the uptake of 131 I-adosterol by both glands were completely inhibited by dexamethasone administration. In primary aldosteronism, six of the 9 patients demonstrated the increased radioactivity in one side, and were diagnosed as aldosteronoma. In 3 cases, failed to show the lesions on standard scintigraphy, the lesions could be detected by suppression scintigraphy, and aldosteronomas measuring 1 x 1 x 0.7, 2 x 2 x 1 and 1.7 x 1.5 x 0.8 cm were confirmed by operation. In Cushing's syndrome, standard scintigraphy could easily distinguish between adenoma (one case) and bilateral hyperplasia (4 cases). Adrenal scintigraphy was also a useful method in order to assess the effect of pituitary irradiation therapy in the case of hyperplasia. In pheochromocytoma and retroperitoneal tumor, the side of the lesion was identified by the absence of a functioning gland. Suppression scintigraphy was particularly useful in detecting the localization of the small tumor in primary aldosteronism. (auth.)

  15. [Patterns of detection of mild cognitive impairment in nursing].

    Science.gov (United States)

    Sebastián Hernández, Ana J; Arranz Santamaría, Luís Carlos

    2017-06-01

    Mild cognitive impairment (MCI) is characterized by an acquired cognitive loss that places individuals, mainly older adults, in an intermediate stage between normal cognitive functioning and dementia. This impairment has a high risk of progression to dementia and is suitable for screening, which allows more effective early intervention. Nursing professionals, especially community-based primary care nurses, play an important role in the detection and follow-up of MCI and in interventions for this condition. The first step should be to take a thorough history from both the patient and his or her carers, which should assess the changes occurring in the patient's daily, family and social life through functional patterns. In subsequent assessment of cognitive function, brief screening tests can be used such as the Mini Mental State Examination (MMSE) or other similar tests. Special attention should be paid to the presence of affective or depressive symptoms, sensory deficits, polypharmacy, decompensated cardiovascular risk factors, and rapid functional deterioration, given their particular influence on MCI. Finally, various nurse-led, non-pharmacological interventions that are effective in MCI can be recommended, based on cardiovascular risk factor control, physical exercise, and cognitive and psychosocial interventions. Copyright © 2017 Sociedad Española de Geriatría y Gerontología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Diagnostic efficacy of the preoperative lymphoscintigraphy, Ga-67 scintigraphy and computed tomography for detection of lymph node metastasis in cases with ovarian or endometrial carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ozalp, S.; Yalcin, O.T.; Polay, S. [Osmangazi Univ. School of Medicine, Dept. of Obstetrics and Gynecology, Eskisehir (Turkey); Aslan, N.; Vardareli, E. [Osmangazi Univ. School of Medicine, Dept. of Nuclear Medicine, Eskisehir (Turkey); Adapinar, B. [Osmangazi Univ. School of Medicine, Dept. of Radiology, Eskisehir (Turkey)

    1999-02-01

    Background: To investigate the diagnostic efficacy of preoperative lymphoscintigraphy (LS), Ga-67 scintigraphy (GS) and computed tomography (CT) for detection of lymph node metastasis in patients with endometrial or ovarian carcinoma. Methods: The results of preoperative LS, GS and CT used to detect lymph node metastasis were compared to the postoperative histopathological results of lymph node dissection materials of a total of 37 patients, including 16 patients with endometrial and 21 patients with ovarian carcinomas. The diagnostic efficacy of these methods for detecting lymph node metastasis were calculated. Results: When the results of all of the patients were taken into account, the preoperative LS, GS and CT were found to have sensitivities of 50%, 20% and 40% and specificities of 51.8%, 96.3%, and 92.6%, respectively, for detection of pelvic lymph node metastasis. The same methods had sensitivities of 27.3%, 27.3% and 72.7% and specificities of 88.5%, 88.5%, 84.6%, respectively, for detecting para-aortic lymph node metastasis in all patients. Conclusion: These data suggested that although LS, GS and CT had relatively high specificity, low sensitivity of these imaging methods precluded their routine preoperative use for diagnosis of lymph node metastasis of ovarian or endometrial carcinoma. (au) 22 refs.

  17. In-111 platelet scintigraphy for detection of lower-extremity deep venous thrombophlebitis: Are 4-hour delayed images sufficient

    International Nuclear Information System (INIS)

    Seabold, J.E.; Conrad, G.R.; Ponto, J.A.; Kimball, D.A.; Frey, E.E.; Coughlan, J.D.; Ahmed, F.; Jensen, K.C.

    1986-01-01

    Twenty-one nonheparinized patients suspected of having lower-extremity deep venous thrombosis underwent 4- and 24-hour In-111-labeled platelet scintigraphy (PS) and lower-extremity contrast venography (CV). Eleven of the 21 patients (52%) had one or more intraluminal filling defects on CV, indicating active thrombophlebitis. In seven of these 11 patients (64%) In-PS was abnormal at 4 hours, and in ten (91%) at 24 hours. All patients with abnormal studies at 4 hours showed greater uptake of more abnormal sites at 24 hours. Of the ten patients with CV-negative studies, two had abnormal bilateral lower pelvis/upper thigh uptake in In-PS at 24 hours. These two In-PS studies were considered to be false positive. Twenty-four-hour In-PS images are necessary if 4-hour images show faint focal uptake of asymmetric blood pool activity, or are normal

  18. A comparative study between TL-201 SPECT myocardial perfusion scintigraphy and dobutamine stress echocardiography in the detection of coronary artery disease at the Philippine Heart Center

    International Nuclear Information System (INIS)

    Ogbac, R.V.; Martinez, A.O.; Obaldo, J.M.; Monzon, O.P.; Torres, J.F.; Rondilla, L.W.S.; Yap, J.S.; Flores, V.B.; Santos, R.J.; Jara, R.D.

    1996-01-01

    Although thallium-201 SPECT myocardial perfusion scintigraphy (MPS) has shown considerable accuracy for the detection of coronary artery disease (CAD), dobutamine stress echocardiography (DSE), a relatively new method for the detection of CAD had been recently utilized at the Philippine Heart Center. To assess its diagnostic worth versus that of thallium-201 spect myocardial scintigraphy (MPS), we studied 18 patients who underwent both procedures. Coronary angiography (CA) was used as the gold standard. MPS was performed with maximal treadmill exercise or with dipyridamole (0.568 mg/kg over 4 minutes) and Tl-201 was injected at peak stress. DSE was performed by infusing dobutamine at an increment of 5 μg/kg/min up to a maximum of 40. Atropine (0.01%) was added when 85% of maximum predicted heart rate is not achieved. Significant stenosis (>70%) was found in 16 out of 18 patients by CA. The sensitivity for the presence of CAD was 88% (14/16) and 69% (11/16) for MPS and DSE respectively. Specificity was 100% (2/2) for both. PPV was 100% for both while NPV was 50% and 29% for MPS and DSE respectively. Diagnostic accuracies were 89% and 72% for MPS and DSE respectively (P>0.05). Sensitivity for detecting left anterior descending artery (LAD) lesion was 71% 64% for MPS and DSE respectively; specificity was 75% and 100% respectively. For the left circumplex artery (LCX) lesion, both MPS and DSE had a sensitivity of 62% and specificity of 60%. Likewise for the right coronary artery (RCA) lesion, both had a sensitivity of 66% and specificity of 50%. Diagnostic accuracies were equal for both tests at 72% for LAD; 61% for LCX; and 61% for RCA. Kappa tests for association shows ρ values of >0.05 for overall and individual CAD detection suggesting no significant difference between MPS and DSE. Although there is a trend showing better detection of CAD with MPS, this particular study shows that both tests are comparable with regards to detection of the presence of CAD and of

  19. Bone scintigraphy in renal osteodystrophy

    International Nuclear Information System (INIS)

    de Graaf, P.; Schicht, I.M.; Pauwels, E.K.J.; te Velde, J.; de Graeff, J.

    1978-01-01

    Bone scintigraphy with Tc-99m HEDP was performed in 30 patients on maintenance hemodialysis, and the results of quantitative analysis were compared wth those of a normal group. To permit this comparison, elevated background activity due to the absence of renal radiotracer excretion was reduced by hemodialysis to levels found in the normals. Histologic proof of renal osteodystrophy had been obtained in all patients. the incidence of radiographic abnormalities was 46%, whereas abnormal scans were found in 25 patients (83%); skeletal lesions were also more pronounced and detected earlier. However, even when the scans appeared normal, the quantitative analysis showed increased skeletal activity in all patients. The total skeletal activity proved to be a good index of the severity of renal osteodystrophy and appeared dependent on both osteomalacia and hyperparathyroidism. These findings show that bone scintigraphy is a sensitive method to detect skeletal involvement in renal osteodystrophy

  20. Evaluation of bone scan by scintigraphy to detect subclinical invasion of the mandible by squamous cell carcinoma of the oral cavity

    International Nuclear Information System (INIS)

    Baker, H.L.; Woodbury, D.H.; Krause, C.J.; Saxon, K.G.; Stewart, R.C.

    1982-01-01

    A prospective study using scintigraphy was performed to compare the sensitivity of the Panorex roentgenogram and the bone scan in detecting subclinical invasion of the mandible by squamous cell carcinoma of the oral cavity and floor of the mouth. Twenty-five patients with squamous cell carcinoma of the floor of the mouth were evaluated preoperatively by both the Panorex and scintigraphic techniques and the results compared with postoperative pathologic findings. In 13 (52%) of the cases, Panorex and scintigraphic techniques were comparable in detecting tumor involvement in bone. In eight cases (32%) all three modalities had normal pathologic indications of the mandible. However, in four cases (16%) results of the scintigraphic techniques were abnormal and the Panorex, normal. In four separate cases, the extent of lesion demonstrable by scintiscanning was greater than delineated by Panorex; surgical specimen confirmed this finding. Pathologic examination of operative specimens confirmed tumor involvement. These data lead us to believe that the scintigraphic techniques may be more sensitive in detecting early mandibular involvement with squamous cell carcinoma than the Panorex technique and may help alter the therapeutic approach

  1. Non-invasive evaluation for pulmonary circulatory impairment during exercise in patients with chronic lung disease; With thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiroshi [Kobe Univ. (Japan). School of Medicine

    1990-06-01

    Thallium-201 myocardial scintigraphy was performed at rest and during exercise on sixteen patients with chronic lung disease to evaluate the secondary pulmonary hypertension during exercise with non-invasive technique. An inverse significant correlation was found between thallium activity ratio (TAR) of left ventricle plus ventricular septum to right ventricle and both of pulmonary vascular resistance and right to left ventricular work index ratio during exercise. The patients were divided into three groups according to mean pulmonary arterial pressure (P-bar{sub PA}) at rest and during exercise: the first group consisted of six patients with pulmonary hypertension during exercise (P-bar{sub PA}: below 25 mmHg at rest and above 30 mmHg during exercise), the second group consisted of four patients with pulmonary hypertension at rest (P-bar{sub PA} above 25 mmHg at rest), and the third group consisted of six patients without pulmonary hypertension (P-bar{sub PA} below 25 mmHg at rest, below 30 mmHg during exercise). In the first group, TAR during exercise was lowered than at rest in four patients, and in the second group TAR during exercise was lowered than at rest in all, while in the third group TAR during exercise was increased than at rest in five patients. These results suggest that thallium-201 myocardial scintigraphy can reflect pulmonary hemodynamics during exercise in patients with chronic lung disease and it is of great use to predict the patients with pulmonary hypertension during exercise. (author).

  2. 99mTc-EDDA/HYNIC-octreotate scintigraphy, an efficient method for the detection and staging of carcinoid tumours: results of 3 years' experience.

    Science.gov (United States)

    Hubalewska-Dydejczyk, A; Fröss-Baron, K; Mikołajczak, R; Maecke, H R; Huszno, B; Pach, D; Sowa-Staszczak, A; Janota, B; Szybiński, P; Kulig, J

    2006-10-01

    At all stages of the disease, serious difficulties are encountered in the imaging diagnosis of carcinoids. Somatostatin receptor scintigraphy (SRS) holds great promise for detecting primary tumours and metastases. 99mTc-EDDA/HYNIC-octreotate should significantly improve the diagnosis of carcinoids in comparison with 111In-Octreoscan owing to the better affinity for SSR2 and the higher count rate. The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-octreotate scintigraphy in the detection and staging of carcinoid tumours. The study population comprised 75 patients (age 48.5+/-15.5 years): 46 with histological confirmation of carcinoid and 29 with suspected disease. 99mTc-EDDA/HYNIC-octreotate (740 MBq) SRS and CT were performed in all patients. Fifteen patients were examined with 111In-Octreoscan. High-quality 99mTc-EDDA/HYNIC-octreotate images were obtained in all cases, with maximum tumour tracer accumulation 4 h p.i. The mean target/non-target ratios for whole body (WB) and SPECT scans were, respectively, as follows: primary lesions: 4.5 and 10.2; metastases: liver, 3.1 and 12.3; abdominal focal lesions, 2.7 and 5.8; lung, 2.7 and 8.3; mediastinum, 3.4 and 7.6; bones, 6.8 and 19.0. 99mTc-EDDA/HYNIC-octreotate WB scans revealed more metastases than 111In-Octreoscan, with better individual separation. 99mTc-EDDA/HYNIC-octreotate SRS revealed new metastatic lesions in seven patients with confirmed carcinoid, and in four with dissemination the primary focus was found. Five patients qualified for radioguided surgery and 11 were referred to 90Y-DOTA-TATE therapy. The sensitivity of SRS in comparison with CT was higher for primary lesions and liver and abdominal lymph node metastases. In the subgroup of patients with suspected neuroendocrine tumours, two duodenal carcinoids, one thymic carcinoid and one ileal carcinoid were found. 99mTc-EDDA/HYNIC-octreotate, with high imaging quality, is an excellent alternative to 111In-Octreoscan for

  3. 99mTc-EDDA/HYNIC-octreotate scintigraphy, an efficient method for the detection and staging of carcinoid tumours: results of 3 years' experience

    International Nuclear Information System (INIS)

    Hubalewska-Dydejczyk, A.; Froess-Baron, K.; Huszno, B.; Pach, D.; Sowa-Staszczak, A.; Mikolajczak, R.; Janota, B.; Maecke, H.R.; Szybinski, P.; Kulig, J.

    2006-01-01

    At all stages of the disease, serious difficulties are encountered in the imaging diagnosis of carcinoids. Somatostatin receptor scintigraphy (SRS) holds great promise for detecting primary tumours and metastases. 99m Tc-EDDA/HYNIC-octreotate should significantly improve the diagnosis of carcinoids in comparison with 111 In-Octreoscan owing to the better affinity for SSR2 and the higher count rate. The aim of this study was to assess the diagnostic efficiency of 99m Tc-EDDA/HYNIC-octreotate scintigraphy in the detection and staging of carcinoid tumours. The study population comprised 75 patients (age 48.5±15.5 years): 46 with histological confirmation of carcinoid and 29 with suspected disease. 99m Tc-EDDA/HYNIC-octreotate (740 MBq) SRS and CT were performed in all patients. Fifteen patients were examined with 111 In-Octreoscan. High-quality 99m Tc-EDDA/HYNIC-octreotate images were obtained in all cases, with maximum tumour tracer accumulation 4 h p.i. The mean target/non-target ratios for whole body (WB) and SPECT scans were, respectively, as follows: primary lesions: 4.5 and 10.2; metastases: liver, 3.1 and 12.3; abdominal focal lesions, 2.7 and 5.8; lung, 2.7 and 8.3; mediastinum, 3.4 and 7.6; bones, 6.8 and 19.0. 99m Tc-EDDA/HYNIC-octreotate WB scans revealed more metastases than 111 In-Octreoscan, with better individual separation. 99m Tc-EDDA/HYNIC-octreotate SRS revealed new metastatic lesions in seven patients with confirmed carcinoid, and in four with dissemination the primary focus was found. Five patients qualified for radioguided surgery and 11 were referred to 90 Y-DOTA-TATE therapy. The sensitivity of SRS in comparison with CT was higher for primary lesions and liver and abdominal lymph node metastases. In the subgroup of patients with suspected neuroendocrine tumours, two duodenal carcinoids, one thymic carcinoid and one ileal carcinoid were found. 99m Tc-EDDA/HYNIC-octreotate, with high imaging quality, is an excellent alternative to 111 In

  4. Comparison of single-dose and double-dose thallium-201 myocardial perfusion scintigraphy for the detection of coronary artery disease and prior myocardial infarction

    International Nuclear Information System (INIS)

    Blood, D.K.; McCarthy, D.M.; Sciacca, R.R.; Cannon, P.J.

    1978-01-01

    Thallium-201 myocardial perfusion scintigraphy was performed after exercise, 4 hours after exercise (redistribution) and after a separate rest injection in 87 patients undergoing coronary arteriography. Significant coronary lesions were present in 62 of the patients. Interpretation of the rest and redistribution scintiscans was the same in 69 patients, 45 of whom had coronary artery disease (CAD). In 16 of the 17 patients with CAD and differing interpretations, defects were present on redistribution scintiscans but not on rest scintiscans; 11 of these patients had evidence of prior transmural myocardial infarction and the other five had an occluded coronary artery supplying the region of the defect. Redistribution scintiscans were more sensitive than rest scintiscans for the detection of prior myocardial infarction (93% vs 54%; P < 0.01). The increased sensitivity was confined to the detection of prior inferior myocardial infarctions. In 36 of 38 patients with persistent perfusion defects on 4-hour redistribution scintiscans, either a prior infarction or an occluded coronary vessel was present. These data demonstrate that redistribution thallium-201 scintiscans may be substituted for conventional rest scintiscans, resulting in reduced cost and radiation exposure to the patients

  5. Mammary scintigraphy

    International Nuclear Information System (INIS)

    Mello, Gustavo Lanza de; Christo, Rodrigo Campos; Paz, Wagner A.; Paim, Soraya P.; Rangel, Kerstim K.; Barroso, Adelanir A.; Lima, Carla Flavia de

    2000-01-01

    The early detection of breast cancer using mammography as screening method lowered 30% breast carcinoma mortality in women over 50 years and also, allowing conservative procedures. Mammography sensitivity has limitations in younger patients with dense fibroglandular tissue. Scintimammography is suitable as a complementary method to mammography in patients with dense breasts, but has low sensitivity in lesion minor than one centimeter in diameter. (author)

  6. Lung scintigraphy; Centellograma pulmonar

    Energy Technology Data Exchange (ETDEWEB)

    Dalenz, Roberto

    1994-12-31

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies.

  7. Scintigraphy in equine practice

    International Nuclear Information System (INIS)

    Fulton, I.C.; Anderson, B.

    2002-01-01

    The most common use for nuclear medicine in equine practice is bone imaging using technetium 99m as the radionuclide. This article will describe establishment of a facility to perform equine scintigraphy, the peculiarities associated with nuclear medicine and horses and describe a variety of the pathology we identify using scintigraphy. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  8. Bile ascites in adults. Diagnosis using hepatobiliary scintigraphy and paracentesis

    International Nuclear Information System (INIS)

    Nagle, C.E.; Fink-Bennett, D.; Freitas, J.E.

    1985-01-01

    Hepatobiliary scintigraphy has been recognized as a useful diagnostic tool in detecting the presence and site of bile leaks. The authors report a case of bile ascites secondary to a postsurgical biliary leak, the scintigraphic findings in bile ascites, and the potential use of paracentesis, in combination with hepatobiliary scintigraphy, in confirming the presence of bile ascites and a bile leak

  9. Early detection by sup(99m)Tc-Sn-pyrophosphate scintigraphy of femoral head necrosis following medial femoral neck fractures

    International Nuclear Information System (INIS)

    Greiff, J.; Lanng, S.; Hoeilund-Carlsen, P.F.; Karle, A.K.; Uhrenholdt, A.

    1980-01-01

    A selected series of 24 patients with displaced medial femoral neck fracture, treated with closed reduction and osteosynthesis with cancellous bone screws (ASIF), were investigated. During an observation period of 6 to 26 months, serial hip joint scintigraphies were performed and compared with serial X-ray examinations. At the first scintigraphic examination performed on average 5-6 weeks after the fracture, two separate investigators found a decreased amount of activity or no activity in the femoral head of 10 and 8 patients, respectively. At the second scintigraphic examination performed on average 11.1 weeks after the fracture both investigators found no activity or a decreased amount of activity in 8 patients. This figure declined to 7 during the following period, because one patient with decreased activity was recorded as having normal activity 15 months after the fracture. These 7 patients all developed radiological signs of femoral head collapse on average 16.3 months after the fracture (range 5-26 months), whereas their scintigrams displayed decreased or absent tracer uptake on average 1.2 months after the fracture (P<0.01). None of the patients with initially normal or increased uptake later showed decreased or absent uptake during the study and none developed radiological collapse. It may be concluded that absent or decreased uptake of sup(99m)Tc-Sn-pyrophosphate in the femoral head following medial femoral neck fracture indicates femoral head necrosis and a high risk of late segmental collapse, whereas normal or increased uptake implying preserved blood supply means that late segmental collapse will probably never develop. (author)

  10. Bone marrow scintigraphy vs bone scintigraphy and radiography in multiple myeloma

    International Nuclear Information System (INIS)

    Feggi, M.; Prandini, N.; Orzincolo, C.; Bagni, B.; Scutellari, P.N.; Spanedda, R.; Gennari, M.; Scapoli, C.L.

    1988-01-01

    The radiography patterns of the skeleton of 73 patients affected by multiple myeloma (MM) were compared to the correspondent scintigraphic findings. Whole body scans were performed using Tc-diphosphonates 99m (bone scintigraphy). And Tc-microcolloides 99m (bone marrow scintigraphy). The results indicate that: a) radiography is more sensitive and accurate than scintigraphy in detecting typical myeloma-related bone lesions; b) bone scintigraphy is useful in detecting alterations in particular locations-i.e. sternum, ribs, scapulae, etc.-which are difficult to demonstrate by plain X-rays; moreover, the recovery of the fractures can be visualized; c) bone marrow scintigraphy is employed to demonstrate the presence of marrow expasion, of cold/hot spots, and relative marrow uptake, related to phagocytic activity. Since in adult men red marrow is confined to the epiphysis of long bones and to the spine, all the diseases affecting bone marrow cause medullary expansion/reduction, which are both easily detected by specific radiopharmaceuticals. The peripheral expasions is clearly documented especially in distal humeri and femora since marrow uptake is included, in healthy adults, in the axial and proximal appendicular skeleton. In spite of its yielding unique informetion, bone marrow scintigraphy remains an additional technique of bone scan, because of its low diagnoditc accuracy

  11. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    Science.gov (United States)

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  12. Diagnostic performance of 11C-choline PET/CT and bone scintigraphy in the detection of bone metastases in patients with prostate cancer.

    Science.gov (United States)

    Kitajima, Kazuhiro; Fukushima, Kazuhito; Yamamoto, Shingo; Kato, Takashi; Odawara, Soichi; Takaki, Haruyuki; Fujiwara, Masayuki; Yamakado, Koichiro; Nakanishi, Yukako; Kanematsu, Akihiro; Nojima, Michio; Hirota, Shozo

    2017-08-01

    The aim of this study was to compare 11C-choline PET/CT and bone scintigraphy (BS) for detection of bone metastases in patients with prostate cancer. Twenty-one patients with histologically proven prostate cancer underwent 11C-choline PET/CT and BS before (n = 4) or after (n = 17) treatment. Patient-, region-, and lesion-based diagnostic performances of bone metastasis of both 11C-choline PET/CT and BS were evaluated using a five-point scale by two experienced readers. Bone metastases were present in 11 (52.4%) of 21 patients and 48 (32.7%) of 147 regions; 111 lesions were found to have bone metastases. Region-based analysis showed that the sensitivity, specificity, accuracy, and area under the receiver-operating-characteristic curves (AUC) of 11C-choline PET/CT were 97.9%, 99.0%, 98.6%, and 0.9989, respectively; those of BS were 72.9%, 99.0%, 90.5%, and 0.8386, respectively. Sensitivity, accuracy, and AUC significantly differed between the two methods (McNemar test, p = 0.0015, p = 0.0015, and p PET/CT detected 110/111 metastatic lesions (99.1%); BS detected 85 (76.6%) (p PET/BS were 100%/90.3% for the blastic type, 91.7%/8.3% for the lytic type, 100%/100% for the mixed type, and 100%/53.3% for the invisible type, respectively. Significant differences in blastic, lytic, and invisible types were observed between the two methods (p = 0.013, p = 0.0044, and p = 0.023, respectively). In conclusion, 11C-choline PET/CT had greater sensitivity and accuracy than BS for detection of bone involvement in patients with prostate cancer.

  13. Older drivers with cognitive impairments : issues of detection and assessment

    OpenAIRE

    Lundberg, Catarina

    2003-01-01

    Older drivers are often presented as a traffic safety problem . Age-related medical conditions such as dementias and stroke impair cognitive functions that are crucial for safe driving Uncertainty remains regarding the most appropriate clinical methods to assess driving fitness in these patient groups. Furthermore, preclinical dementia and cognitive impairment may affect driving performance and lead to an increased crash risk. The first general aim of the thesis was to inve...

  14. Function scintigraphy of the esophagus

    International Nuclear Information System (INIS)

    Leisner, B.; Seidl, I.; Wirsching, R.

    1982-01-01

    In order to evaluate the incidence of esophageal motility disorders associated with gastroesophageal reflux disease we studied the esophageal transit of a sup(99m)Tc-DTPA bolus and the ge-reflux by means of functional scintigraphy. Using the telemetric 24 hours pH-monitoring as reference method in 19 patients, the accuracy of the radioisotope reflux test was found to be 89%. Among 47 patients with histologically proven esophagitis 32 (68%) showed a positive reflux scintiscan result. 17 of them had an impairment of the esophageal clearance which was present in 10 additional cases with a normal reflux study. In 5 patients the results of both tests were within the normal range. A positive reflux scintiscan with or without motility disorder makes a pathological reflux highly probable. Impairment of the esophageal transit combined with a negative reflux test may be due to esophagitis, but also to other functional disorders such as e.g. scleroderma. (orig.) [de

  15. Function scintigraphy of the esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Leisner, B.; Seidl, I.; Wirsching, R.

    1982-08-01

    In order to evaluate the incidence of esophageal motility disorders associated with gastroesophageal reflux disease we studied the esophageal transit of a sup(99m)Tc-DTPA bolus and the ge-reflux by means of functional scintigraphy. Using the telemetric 24 hours pH-monitoring as reference method in 19 patients, the accuracy of the radioisotope reflux test was found to be 89%. Among 47 patients with histologically proven esophagitis 32 (68%) showed a positive reflux scintiscan result. 17 of them had an impairment of the esophageal clearance which was present in 10 additional cases with a normal reflux study. In 5 patients the results of both tests were within the normal range. A positive reflux scintiscan with or without motility disorder makes a pathological reflux highly probable. Impairment of the esophageal transit combined with a negative reflux test may be due to esophagitis, but also to other functional disorders such as e.g. scleroderma.

  16. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  17. Liver and spleen scintigraphy

    International Nuclear Information System (INIS)

    Devries, D.F.

    1988-01-01

    Since the introduction of liver and spleen scintigraphy in the early 1950s, it has undergone considerable changes, the most notable being technetium 99m sulfur colloid, the gamma camera, and single photon emission computed tomography (SPECT). What is the role f liver-spleen scintigraphy in this high-technology society? This chapter attempts to address this question by looking at the radiopharmaceuticals, the technique, and most importantly, the application of scintigraphy to the diagnosis of focal and diffuse hepatic and splenic disease

  18. Detecting Preschool Language Impairment and Risk of Developmental Dyslexia

    Science.gov (United States)

    Helland, Turid; Jones, Lise Øen; Helland, Wenche

    2017-01-01

    This study assessed and compared results from evidence-based screening tools to be filled out by caregivers to identify preschool children at risk of language impairment (LI) and dyslexia. Three different tools were used: one assessing children's communicative abilities, one assessing risk of developmental dyslexia, and one assessing early…

  19. Scintigraphy In skeletal trauma

    African Journals Online (AJOL)

    1989-08-05

    Aug 5, 1989 ... of unsuspected fractures in a patient with multiple injuries. S Atr MedJ 1989; 76: ... of left lumbosacral pain, bone scintigraphy was performed a. Department of ... Moreover, the scan demonstrated seven rib. • •. SAMJ VOL.

  20. Significance of thymic scintigraphy

    International Nuclear Information System (INIS)

    Baba, Hiromi; Oshiumi, Yoshihiko; Nakayama, Chikashi; Morita, Kazunori; Koga, Ichinari

    1978-01-01

    Thymic scintigraphy by 67 Ga-citrate and 75 Se-methionine was done on 6 cases of thymoma, and 5 cases of myasthenia gravis. Scan was positive on 5 of 6 cases of thymoma. All patients with malignant thymoma were positive. Among the 7 cases of myasthenia gravis, scintigrams revealed 2 thymomas and 1 hyperplasia on whom no thymic mass suspected. Thymic scintigraphy is useful examination when dealing with myasthenia gravis. (auth.)

  1. Somatostatin receptor scintigraphy on thyroid carcinoma

    International Nuclear Information System (INIS)

    Pan Weimin; Tan Tianzhi

    2004-01-01

    Purpose: To study the diagnostic value and clinical method of somatostatin receptor scintigraphy on thyroid carcinoma using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent; Methods: Somatostatin receptor scintigraphy (SRS) were performed on 25 patients with thyroid carcinoma, using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent, controlling with 131 I- whole- body- imaging(1312 -WBI). Results: Of 4 patients with MTC (medullary thyroid carcinoma), positive metastasis and primary tumour were detected on 3 patients by SRS, negative results were obtained by 131 I-WBI, the positive detective rate by SRS is 3/4; of 12 patients with PTC (papillary thyroid carcinoma), positive metastasis and primary tumour were detected on 2 patients by SRS or 131 I-WBI,1 of which only by SRS, while negative results were obtained by 131 I- WBI, the positive detective rate by SRS is 3/12; of 8 patients with FTC(follicular thyroid carcinoma), positive metastasis and primary tumour were detected on 1 patients by SRS or 131 I-WBI, and 2 positive results were obtained only by SRS, while negative by 131 I-WBI, the positive detective rate by SRS is 3/8; of 1 patients with HCC (hurthle cell carcinoma ), positive metastasis and primary tumour were detected by SRS, while negative by 131 I-WBI; Conclusions: SRS using 99 Tc m -RC-160 labeled with direct method as scintigraphy reagent has high diagnostic value on thyroid carcinoma, especially on MTC and HCC. (authors)

  2. Biliary scintigraphy in neonatal cytomegalovirus cholestasis

    International Nuclear Information System (INIS)

    Tadzher, I.S.; Grujovska, S.; Todorovski, G.; Josifovska, T.; Arsovska, S.

    1996-01-01

    Diagnostic value of hepatobiliary scintigraphy using mebrofenin-Te-99m was assessed in three newborns with cytomegalovirus (CMV) hepatitis and one baby with hepatitis B jaundice. All cases were affected by persistent jaundice with predominately conjugated bilirubin, alcoholic stools, anemia. One of this newborns (case number 1) was suspected of having biliary atresia due to the absence of intestinal excretion of the tracer. After three weeks intestinal passage was seen in scintiscan late after 24 h. Hepatobiliary scintigraphy represents a non-invasive diagnostic procedure which enables the detection of permeability of the biliary tract. (Author)

  3. Experience in thyroid scintigraphy with Ethiopian patients

    International Nuclear Information System (INIS)

    Demena, Solomon

    1993-01-01

    One thousand and thirty seven thyroid scintigraphy examinations done in the Nuclear Medicine Unit of Tikur Anbesma Hospital, Addis Abeba, Ethiopia between December 1984 and September 1989 were analyzed to assess their diagnostic value. Thirty one percent of the referrals were to investigate clinically detectable solitary nodules, and of these fifty-six percent had ''cold'' nodules and twenty-three percent ''hot'' nodules. Fifty-five percent of the referrals for evaluation of goitre were for multi nodular goitres and twelve percent for diffuse. Thirteen of fifty-three cases with suspected ectopic thyroid tissue were positive. Little useful information was obtained in the evaluation of goitre. It is concluded that thyroid scintigraphy was an unnecessary investigation in the evaluation of goitres in euthyroid patients. Its primary role was in the investigation of the solitary nodule, ectopic thyroid tissue and the retresternal goitre. Therefore, only selected patients should be investigated with thyroid scintigraphy

  4. Somatostatin analogue scintigraphy and tuberculosis: case report

    International Nuclear Information System (INIS)

    Biancheri, I.; Rudenko, B.; Vautrin, P.; Raddoul, J.; Lamfichek, N.; Kantelip, B.; Mantion, G.

    2005-01-01

    Scintigraphy using a radiolabelled somatostatin analogue (111 In-pentetreotide) is useful in the detection of neuroendocrine tumors. But this radiopharmaceutical accumulates also in solid tumours or in inflammatory diseases such as granulomatosis. We present a case of 111 In-pentetreotide uptake in a tuberculous adenopathy. (author)

  5. Critical evaluation of lung scintigraphy in cystic fibrosis: study of 113 patients

    International Nuclear Information System (INIS)

    Piepsz, A.; Wetzburger, C.; Spehl, M.; Machin, D.; Dab, I.; Ham, H.R.; Vandevivere, J.; Baran, D.

    1980-01-01

    A long-term study has been performed on 285 lung perfusion scintigrams obtained from 113 patients with cystic fibrosis. Transverse and longitudinal comparisons with clinical and radiological scores, as well as retrospective analysis of the deceased patients, were the methods used in order to evaluate the importance of the scintigraphic images. It appears that lung scintigraphy is the best index of the regional lung impairment, and contributes, as does a chest radiograph, to the early detection of lung lesions, the two methods being complementary

  6. Assisting the Visually Impaired: Obstacle Detection and Warning System by Acoustic Feedback

    Directory of Open Access Journals (Sweden)

    Andrés Cela

    2012-12-01

    Full Text Available The aim of this article is focused on the design of an obstacle detection system for assisting visually impaired people. A dense disparity map is computed from the images of a stereo camera carried by the user. By using the dense disparity map, potential obstacles can be detected in 3D in indoor and outdoor scenarios. A ground plane estimation algorithm based on RANSAC plus filtering techniques allows the robust detection of the ground in every frame. A polar grid representation is proposed to account for the potential obstacles in the scene. The design is completed with acoustic feedback to assist visually impaired users while approaching obstacles. Beep sounds with different frequencies and repetitions inform the user about the presence of obstacles. Audio bone conducting technology is employed to play these sounds without interrupting the visually impaired user from hearing other important sounds from its local environment. A user study participated by four visually impaired volunteers supports the proposed system.

  7. Improving dementia care: The role of screening and detection of cognitive impairment

    Science.gov (United States)

    Borson, Soo; Frank, Lori; Bayley, Peter J.; Boustani, Malaz; Dean, Marge; Lin, Pei-Jung; McCarten, J. Riley; Morris, John C.; Salmon, David P.; Schmitt, Frederick A.; Stefanacci, Richard G.; Mendiondo, Marta S.; Peschin, Susan; Hall, Eric J.; Fillit, Howard; Ashford, J. Wesson

    2014-01-01

    The value of screening for cognitive impairment, including dementia and Alzheimer's disease, has been debated for decades. Recent research on causes of and treatments for cognitive impairment has converged to challenge previous thinking about screening for cognitive impairment. Consequently, changes have occurred in health care policies and priorities, including the establishment of the annual wellness visit, which requires detection of any cognitive impairment for Medicare enrollees. In response to these changes, the Alzheimer's Foundation of America and the Alzheimer's Drug Discovery Foundation convened a workgroup to review evidence for screening implementation and to evaluate the implications of routine dementia detection for health care redesign. The primary domains reviewed were consideration of the benefits, harms, and impact of cognitive screening on health care quality. In conference, the workgroup developed 10 recommendations for realizing the national policy goals of early detection as the first step in improving clinical care and ensuring proactive, patient-centered management of dementia. PMID:23375564

  8. Evaluation of 99mTc-UBI 29-41 scintigraphy for specific detection of experimental multidrug-resistant Staphylococcus aureus bacterial endocarditis

    NARCIS (Netherlands)

    Brouwer, C.P.J.M.; Gemmel, F.F.A.Y.; Welling, M.M.

    2010-01-01

    Aim. The aim of this paper was to test the ability of technetium-99m labelled synthetic peptide UBI 29-41 scintigraphy (99mTc-UBI 29-41), composed of the antimicrobial peptide ubiquicidin, specifically targets microorganisms in to discriminate between infected and uninfected endocarditis

  9. Detection of hibernating myocardium in patients with myocardial infarction by low-dose dobutamine echocardiography. Comparison with thallium-201 scintigraphy with reinjection

    International Nuclear Information System (INIS)

    Takagi, Tsutomu; Yoshikawa, Junichi; Yoshida, Kiyoshi; Akasaka, Takashi; Honda, Yasuhiro; Yonezawa, Yoshihiro; Shakudo, Masahiro

    1995-01-01

    The identification of hibernating myocardium is important for selecting patients who will benefit from coronary revascularization. The relationship between echocardiographic and radioisotopic markers of hibernating myocardium and postrevascularization recovery of myocardial function was investigated in 21 patients who underwent successful revascularization. Each patient underwent low-dose dobutamine stress echocardiography and thallium-201 ( 201 Tl) scintigraphy with reinjection before revascularization. The presence of contractile reserve in dobutamine stress echocardiography and Tl uptake in 201 Tl scintigraphy with reinjection were defined as markers of hibernating myocardium. Follow-up echocardiograms were evaluated for improved regional wall motion in all patients at a mean of 8.6 months after revascularization. Sensitivity, specificity, and positive and negative predictive values of low-dose dobutamine stress echocardiography for indicating recovery of function after revascularization were 75.0%, 77.8%, 81.8%, and 70.0%, respectively. Sensitivity, specificity, and positive and negative predictive values of 201 Tl scintigraphy with reinjection for indicating recovery of function after revascularization were 91.7%, 55.6%, 73.3%, and 83.3%, respectively. There were no statistical differences between low-dose dobutamine echocardiography and 201 Tl scintigraphy in predicting postrevascularization recovery of function in patients with hibernating myocardium. (author)

  10. Comparison of stress-rest and rest-stress one day myocardial perfusion scintigraphies in detecting coronary artery diseases

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Min, Jung Jun; Song, Ho Cheon; Kim, Ji Yeul

    1997-01-01

    It has been shown that both rest and stress myocardial perfusion imaging with technetium agents can be performed on the same day using two different doses injected within few hours. The purpose of this study was to compare the two protocols (stress-rest and rest-stress) in detecting coronary artery diseases. One hundred and sixty patients (101 males, 59 females, mean age 57±9 years) and 120 patients (79 males, 41 females, mean age 59±10 years) underwent stress-rest myocardial perfusion SPECT and rest-stress myocardial perfusion SPECT, respectively. All of them underwent both myocardial perfusion SPECT and coronary angiography within 1 month. A coronary stenosis was considered significant when it compromised the luminal diameter by ≥50%. The chi square test was used to compare differences in sensitivity, specificity and accuracy between the two groups. The overall sensitivity, specificity and accuracy of stress-rest protocol were 99%, 35% and 68%, respectively. Those of rest-stress protocol were 96%, 47% and 78%, respectively. There was no difference between the two protocols in identifying individual diseased coronary artery branches. Therefore, one day stress-rest and rest-stress myocardial SPECT using 99m Tc agents were comparable and were very sensitive tests in detecting coronary artery diseases

  11. Quantitative assessment of hepatic and splenic blood flow detected by Tc-99m-Sn colloid liver scintigraphy

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Nishiyama, Shoji; Sugimura, Kazuro

    1983-01-01

    Quantitative assessment of hepatic and splenic blood flow detected by injecting Tc-99m-Sn colloid as a bolus was performed on 75 patients who were suspected of having liver disease. Using a computer, the hepatic and splenic time-activity curves were analyzed. Hepatic index was calculated as the ratio of arterial to portal blood flow. The peak time of the right kidney was corresponded to the junction of the arterial and portal phases of the hepatic curve. Splenic index was calculated as the ratio of splenic arterial to liver arterial blood flow. Hepatic and splenic indices had elevated in cases of liver cirrhosis and hepatoma than those of normal controls. There was no significant difference in the hepatic and splenic indices among chronic hepatitis, liver metastasis and normal subject. These noninvasive tests for the hepatic and splenic blood flow may be useful in writing a report of liver scintigram because of the added information of the liver. (author)

  12. Comparison of electrocardiography and thallium-201 myocardial scintigraphy for the detection of ergonovine-induced coronary artery spasm: angiographic correlation

    International Nuclear Information System (INIS)

    Shanes, J.G.; Pavel, D.; Blend, M.

    1987-01-01

    This study was performed to determine the sensitivity of thallium imaging vs ECG monitoring for detecting coronary artery spasm noninvasively following intravenous ergonovine administration as compared to simultaneous coronary angiography. Thirty-two patients with insignificant coronary artery disease and chest pain underwent 12-lead ECG monitoring, thallium imaging, and coronary arteriography following the administration of 0.05, 0.1, 0.2, and 0.3 mg of ergonovine given 5 minutes apart or until chest pain occurred. One minute following the last dose of ergonovine, 2.5 mCi of thallium-201 was injected intravenously, and a final ECG was recorded and repeat coronary arteriography performed. Within 10 minutes following the injection of thallium, imaging was performed in the 40-degree and 70-degree left anterior oblique and anterior projections. The ECG, thallium study, and coronary arteriogram were read blindly and results were compared. The ECG, angiogram, and thallium study were read as positive if the following occurred, respectively: greater than or equal to 1 mm ST segment elevation, depression, or T wave reversal; greater than 50% vessel narrowing,; and reversible perfusion defect. Five patients were excluded from analysis because of either catheter-induced spasm, suboptimal thallium studies, or protocol violations. Of the 27 patients included for analysis, six had chest pain, five had a positive angiogram, five had a positive thallium study, and one had a positive ECG. The sensitivity of thallium vs ECG monitoring was 80% vs 25%, and the accuracy was 92% vs 80%. We conclude that thallium imaging greatly increases the noninvasive detection of ergonovine-induced coronary spasm as compared with the ECG with no loss of accuracy

  13. The value of gastro-oesophageal scintigraphy in the detection of gastro-oesophageal reflux in the infant

    International Nuclear Information System (INIS)

    Le Luyer, B.; Texte, D.; Mallet, E.; Menibus, C.H. de; Segond, G.; Chauman, J.; Noel, J.P.

    1983-01-01

    50 children with a strong clinical suspicion of gastroesophageal reflux and 10 control patients were evaluated with gastroesophageal scintiscans. 500 μCi a 1 mCi of Tc sulfur colloid mixed the patients' routine milk or formula feeding was administred and serial images of the abdomen and thorax were obtained. A positive scintiscan was found in 35 patients (sensitivity 70%) and none of the controls (specificity 100%). A comparison of findings in 34 patients refered for both radiographic and radionucleide studies showed that barium studies were positive in 38% and radionucleide in 64.7%. We found this examination to be more sensitive that the standard barium radiography particularly in patients with respiratory symptoms. We concluded that the GE scintiscan is complementary to barium studies in the diagnosis of GE reflux. Pulmonary aspiration of gastric contents was detected in only a case of the 35 patients with documented GE reflux. A T1/2 emptying gastric longer than 90 minutes (linear calculation) or 105 minutes (exponential calculation) is an indirect GE reflux test. This procedure is simple, safe more physiologic than other available examinations [fr

  14. Value of gastro-oesophageal scintigraphy in the detection of gastro-oesophageal reflux in the infant

    International Nuclear Information System (INIS)

    Le Luyer, B.; Texte, D.; Mallet, E.; Menibus, C.H. de; Segond, G.; Chauman, J.; Noel, J.P.

    1983-01-01

    50 children with a strong clinical suspicion of gastroesophageal reflux and 10 control patients were evaluated with gastroesophageal scintiscans. 500 μCi a 1 mCi of Tc sulfur colloid mixed the patients' routine milk or formula feeding was administred and serial images of the abdomen and thorax were obtained. A positive scintiscan was found in 35 patients (sensitivity 70%) and none of the controls (specificity 100%). A comparison of findings in 34 patients refered for both radiographic and radionucleide studies showed that barium studies were positive in 38% and radionucleide in 64.7%. We found this examination to be more sensitive that the standard barium radiography particularly in patients with respiratory symptoms. We concluded that the GE scintiscan is complementary to barium studies in the diagnosis of GE reflux. Pulmonary aspiration of gastric contents was detected in only a case of the 35 patients with documented GE reflux. A T1/2 emptying gastric longer than 90 minutes (linear calculation) or 105 minutes (exponential calculation) is an indirect GE reflux test. This procedure is simple, safe more physiologic than other available examinations

  15. Value of gastro-oesophageal scintigraphy in the detection of gastro-oesophageal reflux in the infant

    Energy Technology Data Exchange (ETDEWEB)

    Le Luyer, B.; Texte, D.; Mallet, E.; Menibus, C.H. de (Departement de Pediatrie); Dewald, M. (Service de Radiologie Pediatrique, Hopital Charles Nicolle, 76 - Rouen (France)); Segond, G.; Chauman, J.; Noel, J.P. (Departement de Medecine Nucleaire, Centre Henri Becquerel, 76 - Rouen (France))

    1983-12-01

    50 children with a strong clinical suspicion of gastroesophageal reflux and 10 control patients were evaluated with gastroesophageal scintiscans. 500 ..mu..Ci a 1 mCi of Tc sulfur colloid mixed the patients' routine milk or formula feeding was administred and serial images of the abdomen and thorax were obtained. A positive scintiscan was found in 35 patients (sensitivity 70%) and none of the controls (specificity 100%). A comparison of findings in 34 patients refered for both radiographic and radionucleide studies showed that barium studies were positive in 38% and radionucleide in 64.7%. We found this examination to be more sensitive that the standard barium radiography particularly in patients with respiratory symptoms. We concluded that the GE scintiscan is complementary to barium studies in the diagnosis of GE reflux. Pulmonary aspiration of gastric contents was detected in only a case of the 35 patients with documented GE reflux. A T1/2 emptying gastric longer than 90 minutes (linear calculation) or 105 minutes (exponential calculation) is an indirect GE reflux test. This procedure is simple, safe more physiologic than other available examinations.

  16. Bone scintigraphy for horses

    International Nuclear Information System (INIS)

    Jahn, Werner

    2010-01-01

    Scintigraphy (bone scan) is being used approximately since 1980 in the horse under general anaesthesia. With the construction of custom-made overhead gantries for gamma-cameras scintigraphy found widespread entry in big equine referral hospitals for bone-scanning of the standing horse. Indications for the use of a bone scan in the horse are inflammatory alterations in the locomotor apparatus. It is primarily used for diagnosis of lameness of unknown origin, suspect of stress fracture or hairline fracture and for horses with bad riding comfort with suspected painful lesions in the spine. (orig.)

  17. Sensitivity and related factors in iodine-123-β-methyl-p-iodophenyl-pentadecanoic acid myocardial scintigraphy to detect stable effort angina pectoris

    International Nuclear Information System (INIS)

    Tanaka, Tetsuya; Ohtsuki, Yumi; Takechi, Norikazu; Suzuki, Kenji; Nishibori, Yoshiharu; Matsuo, Akiko; Inoue, Keiji; Fujita, Hiroshi; Inoue, Naoto

    2005-01-01

    This study evaluated the sensitivity and the related factors in iodine-123-β-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) scintigraphy to detect stable angina. The subjects were 198 patients with stable angina who underwent BMIPP before percutaneous coronary intervention or coronary bypass graft surgery. Patients with unstable angina, myocardial infarction, congestive heart failure, cardiomyopathy and vasospastic angina were excluded. After investigation of the sensitivity of BMIPP, the patients with single-vessel disease without collateral flow were classified into the normal 12 3 I-BMIPP uptake group (normal group) or decreased 123 I-BMIPP uptake group (decreased group), and various factors were compared between the two groups. Sensitivity was 61% overall, 58% in single-vessel disease, 69% in double-vessel disease, 53% in triple-vessel disease, 43% in only left main vessel disease, and 89% in left main and other vessel disease (NS). In single-vessel disease, the sensitivity was 40% in 75% coronary artery stenosis, 58% in 90% stenosis, 89% in 99% stenosis, and 69% in total occlusion (p=0.003). Comparing the decreased and normal groups, diabetes mellitus was more frequent in the normal group (14.6% vs 39.5%), minimal lumen diameter was smaller (0.75±0.37 vs 0.98±0.49 mm) and lesion length was longer in the decreased group (15.4±4.9 vs 11.6±5.5 mm). Logistic multivariate analysis showed that the independent factors were diabetes mellitus [odds ratio 0.20, 95% confidence interval (CI) 0.04-0.87, p=0.03], minimal lumen diameter (odds ratio 0.10, 95% CI 0.02-0.48, p=0.003) and lesion length (odds ratio 1.12, 95% CI 1.00-1.25, p=0.03). BMIPP is useful in stable angina patients because of the acceptable sensitivity. Diabetes mellitus, minimal lumen diameter and lesion length were independent factors associated with decreased BMIPP uptake. (author)

  18. [{sup 11}C]Choline PET/CT detection of bone metastases in patients with PSA progression after primary treatment for prostate cancer: comparison with bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Picchio, Maria [San Raffaele Scientific Institute, Nuclear Medicine Department, Milan (Italy); National Research Council (IBFM-CNR), Institute for Bioimaging and Molecular Physiology, Milan (Italy); Spinapolice, Elena Giulia; Crivellaro, Cinzia [University of Milano-Bicocca, Center for Molecular Bioimaging, Milan (Italy); Fallanca, Federico; Gianolli, Luigi [San Raffaele Scientific Institute, Nuclear Medicine Department, Milan (Italy); Giovacchini, Giampiero [University of Milano-Bicocca, Center for Molecular Bioimaging, Milan (Italy); University Hospital Basel, Institute of Nuclear Medicine, Basel (Switzerland); Messa, Cristina [National Research Council (IBFM-CNR), Institute for Bioimaging and Molecular Physiology, Milan (Italy); University of Milano-Bicocca, Center for Molecular Bioimaging, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine, Monza (Italy)

    2012-01-15

    The aim of this study was to evaluate the clinical usefulness of [{sup 11}C]choline positron emission tomography (PET)/CT in comparison with bone scintigraphy (BS) in detecting bone metastases (BM) of patients with biochemical progression after radical treatment for prostate cancer (PCa). Seventy-eight consecutive patients with biochemical progression of PCa (mean prostate-specific antigen 21.1 ng/ml, range 0.2-500.0 ng/ml) referred for both [{sup 11}C]choline PET/CT and BS for restaging purposes were retrospectively analysed. The diagnostic accuracy of [{sup 11}C]choline PET/CT and BS was assessed by using morphological imaging and/or follow-up as standards of reference. As equivocal findings were found, the accuracy analysis was performed twice, once including them as positive and once as negative. A separate analysis was also performed in hormone-resistant patients and data compared with those of patients who did not receive anti-androgenic treatment. Equivocal findings occurred in 1 of 78 (1%) cases in [{sup 11}C]choline PET/CT and in 21 of 78 (27%) cases in BS. Depending on their attribution as either positive or negative, the ranges of sensitivity, specificity, positive predictive value, negative predictive value and accuracy for [{sup 11}C]choline PET/CT were 89-89%, 98-100%, 96-100%, 94-96% and 95-96%, respectively. For BS they were 100-70%, 75-100%, 68-100%, 100-86% and 83-90%, respectively. Concordant findings between [{sup 11}C]choline PET/CT and BS occurred in 55 of 78 (71%) cases. The accuracy of [{sup 11}C]choline PET/CT did not significantly (p = 0.30) differ between hormone-resistant patients (97%) and those who did not receive anti-androgenic treatment (95%). In clinical practice, [{sup 11}C]choline PET/CT may not replace BS because of its lower sensitivity. However, for its high specificity, [{sup 11}C]choline PET/CT positive findings may accurately predict the presence of BM. Equivocal findings are more frequent in BS than [{sup 11}C]choline PET

  19. Detection of memory impairment in a community-based system: a collaborative study.

    Science.gov (United States)

    Kiral, Kahraman; Ozge, Aynur; Sungur, Mehmet Ali; Tasdelen, Bahar

    2013-05-01

    The ability to distinguish between older people with cognitive impairment and those who age in a healthy manner is crucial because cognitive impairment may be a precursor to full-blown dementia. Therefore, an early diagnosis of cognitive impairment is important. However, patients are often admitted to a hospital only when they already have a serious cognitive impairment. Consequently, cooperative studies between clinics and community-based organizations may assist hospitals in detecting early cognitive impairment. This article examines how community-based organizations can contribute to the early diagnosis of dementia. A cooperation model between the Neurology Department of Mersin University Hospital and the Mersin branch of the Alzheimer's Association was developed. Trained professionals used a neuropsychological battery to evaluate 50 individuals at the Mersin branch of the Alzheimer's Association in Turkey. Individuals whose performance fell below the average (1 standard deviation or less) were subsequently referred to the hospital. On the basis of the neurological and neuropsychological assessments, 11 participants were placed in the mild cognitive impairment group and 39 were placed in the healthy group. The results suggest that the Standardized Mini-Mental State Examination and the Three Words-Three Shapes Test are useful tools for detecting early memory impairments in a community-based setting.

  20. Thallium-technetium-subtraction scintigraphy in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Adalet, I.; Hawkins, T.; Clark, F.; Wilkinson, R.

    1994-01-01

    Between 1983 and 1992 thallium-technetium subtraction scintigraphy (TTS) was performed on 74 patients with clinical and biochemical evidence of hyperparathyroidism. Twenty-five of the 53 investigations since 1988 were conducted on patients with renal failure with a suspicion of secondary hyperparathyroidism. In a retrospective study we have evaluated radioisotope scintigraphy for patients with adenoma and for renal failure patients with possible parathyroid hyperplasia. Thirty of 74 patients underwent neck exploration. Scintigraphy detected 17 of 24 parathyroid adenomas (sensitivity 71%). In contrast, in six renal patients who came to operation, scintigraphy localised only 5 of 20 hyperplastic parathyroid glands (sensitivity 25%) and in one renal patient we localised a parathyroid adenoma. A review of the literature shows low detection rates for hyperplasia by TTS to be a common observation. Based on these findings a rational approach is offered for parathyroid localisation in renal patients prior to neck exploration. (orig.)

  1. Detection and localization of enlarged parathyroid glands in patients with hyperparathyroidism using 99mTc-methoxyisobutylisonitrile (MIBI). A study of subtraction scintigraphy with 99mTc-pertechnetate

    International Nuclear Information System (INIS)

    Katagiri, Makoto; Ohtawa, Takahiro; Otsuka, Nobuaki; Morita, Koichi; Sone, Teruki; Mimura, Hiroaki; Yanagimoto, Shinichi; Fukunaga, Masao; Harada, Tanekazu

    1995-01-01

    In this study we investigated the detectability of abnormal parathyroid gland(s) by 99m Tc-methoxy-isobutylisonitrile (MIBI) scintigraphy in patients with hyperparathyroidism. The subjects were 6 patients with primary hyperparathyroidism (PHP) with a single adenoma and 13 patients with renal hyperparathyroidism (RHP) on chronic maintenance hemodialysis. The imaging data of 99m Tc-pertechnetate were subtracted from those of 99m Tc-MIBI (MIBI-Tc), and number and location of the positive images on scintigrams were compared with those obtained by conventional scintigraphy using 201 Tl-Cl and 99m Tc-pertechnetate (Tl-Tc). All of the patients underwent surgery, and the number and location of the abnormal parathyroid glands were confirmed. The number of resected parathyroid glands were 6 in PHP and 52 in RHP. The detectability of MIBI-Tc was 83.3% in PHP and 51.9% in RHP, while that of Tl-Tc was 100% and 44.2%, respectively. Although no statistically significant difference in the detectability was found between MIBI-Tc and Tl-Tc, the number of false positives with MIBI-Tc was less than that with Tl-Tc. The detectability of MIBI-Tc depended on the size of the parathyroid gland. The maximal diameter and weight of the smallest parathyroid gland detected were 15 mm and 290 mg in PHP, and 9 mm and 50 mg in RHP. The existence of the thyroid gland did not reduce the detectability of MIBI-Tc. In conclusion, MIBI-Tc was clinically very useful for the detection of abnormal parathyroid glands in patients with hyperparathyroidism. (author)

  2. Myocardial scintigraphy: methods and indications

    International Nuclear Information System (INIS)

    Knapp, W.H.

    1993-01-01

    Myocardial scintigraphy comprises perfusion imaging using TI-201 or - more recently - Tc-99m-labeled compounds with high affinity to myocytes. Imaging with these agents has become an important procedure in the detection of coronary artery disease, particularly in patients with non-diagnostic stress-ECG, in the functional evaluation of coronary stenoses after angiographical documentation in order to meet the adequate therapy decision, in therapy monitoring and follow-up, in the post infarction assessment of myocardial viability and differentiation between severe ischemia and scar and, occasionally, in acute ischemia. The use of positron emitters does not offer significant advantages for mere perfusion imaging, but is indispensable for the scintigraphic investigation of certain aspects of myocardial metabolism, particularly for the differentiation of viable ischemic wall segments from irreversibly damaged tissue. Imaging of myocardial necrosis has been improved by the introduction of labeled antimyosin antibody fragments and offers a considerable clinical potential in the diagnosis of myocarditis and cardiac transplant rejection. Neurohumoral aspects are increasingly involved in our understanding of myocardial failure. Scintigraphy of innervation/neurotransmission contributes to the investigation of pathophysiological alterations in myocardial insufficiency and in heart transplants. (orig.) [de

  3. The thallium-201 myocardial scintigraphy, its possibilities and limitations

    International Nuclear Information System (INIS)

    Adam, W.; Meindl, S.; Schmitz, A.; Utech, C.; Boettcher, D.

    1983-01-01

    The Thallium-201 Myocardial Scintigraphy, its Possibilities and limitations: The Thallium-201 myocardial scintigraphy is a simple non-invasive procedure to detect hypo- and non-perfused myocardial regions. In the he last years it was demonstrated to be a helpful method in the diagnostic strategy for the cardiologist. It can not replace the coronary angiogram, but in many cases it appears to be useful in selecting patients for coronary angiography. (orig.) [de

  4. Generalized Linear Models of Home Activity for Automatic Detection of Mild Cognitive Impairment in Older Adults*

    Science.gov (United States)

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2015-01-01

    With a globally aging population, the burden of care of cognitively impaired older adults is becoming increasingly concerning. Instances of Alzheimer’s disease and other forms of dementia are becoming ever more frequent. Earlier detection of cognitive impairment offers significant benefits, but remains difficult to do in practice. In this paper, we develop statistical models of the behavior of older adults within their homes using sensor data in order to detect the early onset of cognitive decline. Specifically, we use inhomogenous Poisson processes to model the presence of subjects within different rooms throughout the day in the home using unobtrusive sensing technologies. We compare the distributions learned from cognitively intact and impaired subjects using information theoretic tools and observe statistical differences between the two populations which we believe can be used to help detect the onset of cognitive decline. PMID:25570050

  5. Generalized Linear Models of home activity for automatic detection of mild cognitive impairment in older adults.

    Science.gov (United States)

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2014-01-01

    With a globally aging population, the burden of care of cognitively impaired older adults is becoming increasingly concerning. Instances of Alzheimer's disease and other forms of dementia are becoming ever more frequent. Earlier detection of cognitive impairment offers significant benefits, but remains difficult to do in practice. In this paper, we develop statistical models of the behavior of older adults within their homes using sensor data in order to detect the early onset of cognitive decline. Specifically, we use inhomogenous Poisson processes to model the presence of subjects within different rooms throughout the day in the home using unobtrusive sensing technologies. We compare the distributions learned from cognitively intact and impaired subjects using information theoretic tools and observe statistical differences between the two populations which we believe can be used to help detect the onset of cognitive decline.

  6. "Lie to me"-Oxytocin impairs lie detection between sexes.

    Science.gov (United States)

    Pfundmair, Michaela; Erk, Wiebke; Reinelt, Annika

    2017-10-01

    The hormone oxytocin modulates various aspects of social behaviors and even seems to lead to a tendency for gullibility. The aim of the current study was to investigate the effect of oxytocin on lie detection. We hypothesized that people under oxytocin would be particularly susceptible to lies told by people of the opposite sex. After administration of oxytocin or a placebo, male and female participants were asked to judge the veracity of statements from same- vs. other-sex actors who either lied or told the truth. Results showed that oxytocin decreased the ability of both male and female participants to correctly classify other-sex statements as truths or lies compared to placebo. This effect was based on a lower ability to detect lies and not a stronger bias to regard truth statements as false. Revealing a new effect of oxytocin, the findings may support assumptions about the hormone working as a catalyst for social adaption. Copyright © 2017. Published by Elsevier Ltd.

  7. A case of muscular sarcoidosis diagnosed by gallium-67 scintigraphy and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sohn, Hyung Sun; Kim, Euy Neyng

    1999-01-01

    Gallium-67 scintigraphy is helpful in the assessment of active extrapulmonary sarcoidosis. Muscular involvement of sarcoidosis is often asymptomatic or nonspecific, and laboratory examinations do not provide convincing evidence of muscular involvement. We report a case of muscular sarcoidosis, which was detected by gallium-67 scintigraphy. In a patient who was suffering from fever and arthalgia of knee joint, gallium-67 scintigraphy showed mediastinal and hilar involvement of sarcoidosis with unexpected extensive muscular uptake. Magnetic resonance imaging revealed the detailed depiction of intramuscular infiltration of sarcoid granuloma. Gallium-67 scintigraphy is useful in detecting inflammatory muscular involvement of sarcoidosis as well as other multiorgan involvement

  8. Bone scintigraphy in children

    International Nuclear Information System (INIS)

    Mann, M.D.

    2004-01-01

    Full text: Bone scintigraphy is an integral part of the evaluation of bone disease in children. Common indications are suspected infection or inflammation, bone tumours and metastases, trauma and avascular necrosis. In all these disorders the sensitivity of scintigraphy is high. Gallium scintigraphy is often useful in children with clinical signs of infection not responding to treatment but the radiation dose is high. High quality images are essential. They depend on the full participation and co-operation of the child, parents and radiographers, the administration of appropriate analgesics, gentle but firm handling of the child, the injection of the appropriate amount of radiopharmaceutical, good positioning and immobilization, optimised equipment, and the acquisition of a suitable number of counts in an appropriate matrix size. Unless there are specific reasons for not doing so, we routinely perform two phase bone scintigraphy. This usually involves whole body blood pool and delayed images followed by static images of selected areas and, less often, pinhole images or SPECT. The interpretation of bone scan images in children requires knowledge of the age dependent differences in bone metabolism in the developing skeleton and the effect on the appearance of the maturing skeleton. (author)

  9. Bone scintigraphy in chondroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Humphry, A.; Gilday, D.L.; Brown, R.G.

    1980-11-01

    Scintigraphy in 3 patients with chondroblastoma showed that the tumors were hyperemic and avidly accumulated the radionuclide. These changes were also present in adjacent normal bone, but to a lesser degree. This suggests that radionuclide uptake in chondroblastoma is a function of the blood supply to the tumor rather than primary matrix extraction.

  10. IN SEARCH OF A FAST SCREENING METHOD FOR DETECTING THE MALINGERING OF COGNITIVE IMPAIRMENT

    Directory of Open Access Journals (Sweden)

    Amada Ampudia

    2012-07-01

    Full Text Available Forensic settings demand expedient and conclusive forensic psychological assessment. The aim of this study was to design a simple and fast, but reliable psychometric instrument for detecting the malingering of cognitive impairment. In a quasi-experimental design, 156 individuals were divided into three groups: a normal group with no cognitive impairment; a Mild Cognitive Impairment (MCI group; and a group of informed malingerers with no MCI who feigned cognitive impairment. Receiver Operating Curve (ROC analysis of the Test of Memory Malingering (TOMM, and of several subtests of the Wechsler Memory Scale (WMS-III revealed that the WMS-III was as reliable and accurate as the TOMM in discriminating malingerers from the honest. The results revealed that the diagnostic accuracy, sensitivity and specificity of the WMS-III Auditory Recognition Delayed of Verbal Paired Associates subtest was similar to the TOMM in discriminating malingering from genuine memory impairment. In conclusion, the WMS-III Recognition of Verbal Paired Associates subtest and the TOMM provide a fast, valid and reliable screening method for detecting the malingering of cognitive impairment.

  11. Detecting delirium in elderly outpatients with cognitive impairment.

    Science.gov (United States)

    Stroomer-van Wijk, Anne J M; Jonker, Barbara W; Kok, Rob M; van der Mast, Roos C; Luijendijk, Hendrika J

    2016-08-01

    Delirium may be more prevalent in elderly outpatients than has long been assumed. However, it may be easily missed due to overlap with dementia. Our aim was to study delirium symptoms and underlying somatic disorders in psycho-geriatric outpatients. We performed a case-control study among outpatients that were referred to a psychiatric institution between January 1st and July 1st 2010 for cognitive evaluation. We compared 44 cases with DSM-IV delirium (24 with and 20 without dementia) to 44 controls with dementia only. All participants were aged 70 years or older. We extracted from the medical files (1) referral characteristics including demographics, medical history, medication use, and referral reasons, (2) delirium symptoms, scored with the Delirium Rating Scale-Revised-98, and (3) underlying disorders categorized as: drugs/intoxication, infection, metabolic/endocrine disturbances, cardiovascular disorders, central nervous system disorders, and other health problems. At referral, delirium patients had significantly higher numbers of chronic diseases and medications, and more often a history of delirium and a recent hospital admission than controls. Most study participants, including those with delirium, were referred for evaluation of (suspected) dementia. The symptoms that occurred more frequently in cases were: sleep disturbances, perceptual abnormalities, delusions, affect lability, agitation, attention deficits, acute onset, and fluctuations. Drug related (68%), infectious (61%), and metabolic-endocrine (50%) disturbances were often involved. Detection of delirium and distinction from dementia in older outpatients was feasible but required detailed caregiver information about the presence, onset, and course of symptoms. Most underlying disorders could be managed at home.

  12. Optimizing renal DMSA-scintigraphy with 7-pinhole collimator

    International Nuclear Information System (INIS)

    Botsch, H.; Pottmeyer, A.; Savaser, A.; Lochner, B.; Felix, R.

    1982-01-01

    Multiple pinhole emission tomographic imaging techniques are currently being applied to imaging of organs of a limited size. The purpose of this study was to evaluate the feasibility of this technique in kidney imaging with Tcsup(99m)-DMSA. A 7-pinhole collimator having 4.5 mm. pinhole apertures was used in conjunction with a widefield camera. Left and right kidney were imaged separately. Twelve small renal cysts with a diameter of 1 to 3.5 cm. verified by US or CAT were investigated by 7-pinhole and planar scintigraphy. Eight of 12 renal cysts were identified by 7-pinhole scintigraphy whereas only one cyst was seen by planar scintigraphy. The borderline of cysts detection was 1.5 cm. in 7-pinhole tomography. Basing on these comparative studies and experiences on many patient investigations it seems reasonable to perform renal scintigraphy with 7-pinhole tomography in a routine manner. (orig.)

  13. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases

    International Nuclear Information System (INIS)

    Martins, L.R.; Marioni Filho, H.; Romaldini, H.; Uehara, C.; Alonso, G.

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author)

  14. Usefulness of 99mTc MIBI scintigraphy in hyperparathyroidism. A retrospective analysis of the surgical patients

    International Nuclear Information System (INIS)

    Nakamura, Toshiyuki; Kobayashi, Shinya; Fujimori, Minoru

    1998-01-01

    In patients who receive surgery for primary or secondary hyperparathyroidism, preoperative diagnosis of the location of the parathyroid glands is important. Ninety-nine-m Technetium methoxyisobutylisonitrile (MIBI) accumulates in the pathological parathyroid. We used MIBI scintigraphy to detect diseased parathyroid glands in 20 patients with hyperparathyroidism, and successfully located the glands in seventeen. The accuracy of MIBI scintigraphy (100%) is significantly (p<0.05) better than that of Thallium-Technetium subtraction scintigraphy (56%). In a patient with hyperparathyroidism due to an ectopic parathyroid gland, MIBI scintigraphy showed accumulation in a mediastinal gland. MIBI scintigraphy is thus useful for gland location in hyperparathyroidism. (author)

  15. Skin Autofluorescence Based Decision Tree in Detection of Impaired Glucose Tolerance and Diabetes

    NARCIS (Netherlands)

    Smit, Andries J.; Smit, Jitske M.; Botterblom, Gijs J.; Mulder, Douwe

    2013-01-01

    Aim: Diabetes (DM) and impaired glucose tolerance (IGT) detection are conventionally based on glycemic criteria. Skin autofluorescence (SAF) is a noninvasive proxy of tissue accumulation of advanced glycation endproducts (AGE) which are considered to be a carrier of glycometabolic memory. We

  16. Detection of Impaired Cerebral Autoregulation Using Selected Correlation Analysis: A Validation Study.

    Science.gov (United States)

    Proescholdt, Martin A; Faltermeier, Rupert; Bele, Sylvia; Brawanski, Alexander

    2017-01-01

    Multimodal brain monitoring has been utilized to optimize treatment of patients with critical neurological diseases. However, the amount of data requires an integrative tool set to unmask pathological events in a timely fashion. Recently we have introduced a mathematical model allowing the simulation of pathophysiological conditions such as reduced intracranial compliance and impaired autoregulation. Utilizing a mathematical tool set called selected correlation analysis (sca), correlation patterns, which indicate impaired autoregulation, can be detected in patient data sets (scp). In this study we compared the results of the sca with the pressure reactivity index (PRx), an established marker for impaired autoregulation. Mean PRx values were significantly higher in time segments identified as scp compared to segments showing no selected correlations (nsc). The sca based approach predicted cerebral autoregulation failure with a sensitivity of 78.8% and a specificity of 62.6%. Autoregulation failure, as detected by the results of both analysis methods, was significantly correlated with poor outcome. Sca of brain monitoring data detects impaired autoregulation with high sensitivity and sufficient specificity. Since the sca approach allows the simultaneous detection of both major pathological conditions, disturbed autoregulation and reduced compliance, it may become a useful analysis tool for brain multimodal monitoring data.

  17. Detection of Impaired Cerebral Autoregulation Using Selected Correlation Analysis: A Validation Study

    Directory of Open Access Journals (Sweden)

    Martin A. Proescholdt

    2017-01-01

    Full Text Available Multimodal brain monitoring has been utilized to optimize treatment of patients with critical neurological diseases. However, the amount of data requires an integrative tool set to unmask pathological events in a timely fashion. Recently we have introduced a mathematical model allowing the simulation of pathophysiological conditions such as reduced intracranial compliance and impaired autoregulation. Utilizing a mathematical tool set called selected correlation analysis (sca, correlation patterns, which indicate impaired autoregulation, can be detected in patient data sets (scp. In this study we compared the results of the sca with the pressure reactivity index (PRx, an established marker for impaired autoregulation. Mean PRx values were significantly higher in time segments identified as scp compared to segments showing no selected correlations (nsc. The sca based approach predicted cerebral autoregulation failure with a sensitivity of 78.8% and a specificity of 62.6%. Autoregulation failure, as detected by the results of both analysis methods, was significantly correlated with poor outcome. Sca of brain monitoring data detects impaired autoregulation with high sensitivity and sufficient specificity. Since the sca approach allows the simultaneous detection of both major pathological conditions, disturbed autoregulation and reduced compliance, it may become a useful analysis tool for brain multimodal monitoring data.

  18. Thallium 201 Scintigraphy

    Science.gov (United States)

    McKillop, James H.

    1980-01-01

    The radioactive isotope thallium 201 behaves physiologically as a potassium analog, and when injected intravenously accumulates rapidly within the cells of many organs. Uptake of the isotope reflects both regional perfusion and sodium-potassium pump activity. The radionuclide emits 80 keV x-rays which are suitable for scintillation camera imaging. The main clinical application of 201TI scintigraphy has been in myocardial imaging. Abnormal uptake of the isotope results in a cold spot on the myocardial image. In patients with coronary artery disease, the differentiation of ischemic and infarcted myocardium is made by comparing images obtained after injecting the radionuclide at the peak of a maximal exercise test with those obtained after injection at rest. Abnormalities due to ischemia usually are seen only on the stress image whereas fixed defects in both rest and stress studies usually indicate areas of infarction or scarring. Some investigators believe that redistribution images obtained four to six hours after stress injection (without administering further 201TI) give the same information as a separate rest study. The sensitivity of stress imaging for detecting significant coronary disease is of the order of 80 percent to 95 percent, though computer processing of the images may be necessary to achieve the higher figure. The prediction of the extent of coronary disease from 201TI images is less reliable. An abnormal 201TI image is not entirely specific for coronary artery disease and the likelihood of an abnormal image being due to this diagnosis varies according to the clinical circumstances. The main clinical value of 201TI myocardial imaging is likely to be in the noninvasive screening of patients with atypical chest pain or with ambiguous findings on stress electrocardiographic tests. It has also proved useful in studying patients with variant angina or following a coronary bypass operation. It is doubtful whether the technique is clinically helpful in most

  19. Pancreatic scintigraphy in diabetes mellitus

    International Nuclear Information System (INIS)

    Shio, Hiroshi; Ueki, Jyuichi; Nomura, Kozi; Nakamura, Yoshifumi

    1983-01-01

    Pancreatic scintigraphy was performed on 67 diabetic patients (42 males and 25 females) in order to study exocrine pancreatic functions in primary diabetes. Relationships between visualization and the onset age, sex, morbid period, presence or absence of retinitis, good or poor control of blood glucose control and the therapeutic modality of diabetes were examined. Abnormality was detected in 34 cases (50.7%), being frequent among male patients in their 50s. The more serious the diabetes, i.e., with a longer morbid period, poorer blood glucose control and worse retinitis, the higher was the frequency of abnormality in pancreatic visualization. The frequency of abnormality was high in association with insulin treatment, oral tablets and single dietary treatment in that order. The more severe the hypoinsulinism, the higher was the frequency of abnormality. This technique can be used as a screening means for exocrine pancreatic function tests on diabetics. (Chiba, N.)

  20. Static and dynamic thyroid scintigraphy

    International Nuclear Information System (INIS)

    Mahlstedt, J.

    1986-01-01

    Static images as isolated investigation in thyroid diagnosis mainly provides morphologic information, and therefore sonography is largely applied for this purpose. 99m Tc-pertechnetate scans or 123 I-scans are indicated in cases of malpositions and serve to clarify lesions of unknown dignity. Additionally 201 Tl-chloride is suited for examinations with regard to metabolically active thyroid tissue, whereby differential diagnostic laboratory tests must be carried out to exclude parathyroid adenoma. Dynamic thyroid scans before and after regulation tests (suppression, stimulation) reflect the physiological correlation between the iodine avidity of the thyroid, the peripheral thyroid hormone concentrations and the hypophyseal regulation in the TRH-test. The main application of this procedure is the clarification of thyroid autonomy, i.e. indication, detection, quantification or exclusion of thyroid autonomy. For the treatment of immunogenic thyrotoxicosis, dynamic thyroid scintigraphy provides important information about the onset of remission, thus permitting to end thyreostatic therapy. (orig.) [de

  1. Gallium-67 scintigraphy and the Heart

    International Nuclear Information System (INIS)

    Garayt, D.

    1987-01-01

    Although gallium-67 was initially used for tumor imaging, clinical studies suggested its potential use as a method of detecting occult inflammatory lesions. The demonstration of diffuse myocardial uptake of gallium-67 during Lyme disease myocarditis is consistent with a pattern of diffuse myocarditis as seen in sarcoid myocarditis. Two cases are presented. A critical review of the various applications of gallium-67 scintigraphy to myocardium investigation is carried out [fr

  2. Hepatobiliary scintigraphy in patients with bile leaks

    International Nuclear Information System (INIS)

    Carichner, S.L.; Nagle, C.E.

    1987-01-01

    Hepatobiliary scintigraphy has been recognized as a useful tool in detecting the presence and sites of bile leaks. The clinical settings in which bile leaks are likely to occur, as well as some of the scintigraphic patterns seen in patients with bile leaks, are reviewed here. Tips for technologists are offered on interventions that might enhanced the quality of information available to the nuclear physician

  3. Gated equilibrium bloodpool scintigraphy

    International Nuclear Information System (INIS)

    Reinders Folmer, S.C.C.

    1981-01-01

    This thesis deals with the clinical applications of gated equilibrium bloodpool scintigraphy, performed with either a gamma camera or a portable detector system, the nuclear stethoscope. The main goal has been to define the value and limitations of noninvasive measurements of left ventricular ejection fraction as a parameter of cardiac performance in various disease states, both for diagnostic purposes as well as during follow-up after medical or surgical intervention. Secondly, it was attempted to extend the use of the equilibrium bloodpool techniques beyond the calculation of ejection fraction alone by considering the feasibility to determine ventricular volumes and by including the possibility of quantifying valvular regurgitation. In both cases, it has been tried to broaden the perspective of the observations by comparing them with results of other, invasive and non-invasive, procedures, in particular cardiac catheterization, M-mode echocardiography and myocardial perfusion scintigraphy. (Auth.)

  4. Detection of memory impairment among community-dwelling elderly by using the Rivermead Behavioural Memory Test

    International Nuclear Information System (INIS)

    Shinagawa, Shunichiro; Toyota, Yasutaka; Matsumoto, Teruhisa; Sonobe, Naomi; Adachi, Hiroyoshi; Mori, Takaaki; Ishikawa, Tomohisa; Fukuhara, Ryuji; Ikeda, Manabu

    2010-01-01

    The aim of this study was to use the Rivermead Behavioural Memory Test (RBMT) to evaluate everyday memory impairment among community-dwelling elderly who had normal cognitive function and performed daily activities normally but displayed memory impairments, and to diagnose the condition as either mild cognitive impairment or dementia. Among the 1,290 community-dwelling elderly persons who participated in the study, 72 subjects scored higher than 24 on the Mini-Mental State Examination (MMSE): these subjects performed daily activities normally, but their family members reported that they showed memory impairments. Fifty-two subjects completed RBMT, Clinical Dementia Rating, and brain computed tomography, and a final diagnosis was established. The mean standard profile score was 15.1±5.0 and mean screening score was 6.4±3.0. RBMT score was correlated with the MMSE score. Nine of the subjects were diagnosed with dementia and 26 of them were found to be normal. RBMT achieved 100% sensitivity and specificity with regard to the differentiation of subjects with Alzheimer's disease. However, some subjects were diagnosed with dementia even though their RBMT score was higher than the cut-off score. RBMT was useful in detecting memory impairments of Alzheimer's disease (AD) subjects in community-based surveys. However, some subjects were diagnosed with dementia because of the existence of other cognitive impairments among community-dwelling elderly. (author)

  5. Bone scintigraphy in craniosysnostosis

    International Nuclear Information System (INIS)

    Marchandise, X.; Dhellemmes, P.; Steinling, M.; Pellerin, P.; Dujardin, M.H.

    1981-01-01

    The scintigraphy of the skull has been studied in 49 children. This investigation is awkward to be performed and to be interpretated. The hyperactivity over a suture is far to be univocal. The hypoactivity over a suture can only be picked up under some circumstances. Abnormal parasagittal activities may be seen in craniostenosis. The interest of the scan in the establishment of the diagnosis or surgical indication seems to be limited above 5 years. Pronostic and physiopathologic interest needs more complete investigation [fr

  6. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  7. The clinical use of platelet scintigraphy with 111-In-oxine

    International Nuclear Information System (INIS)

    Kessler, C.; Reuther, R.; Berentelg, J.; Kimmig, B.

    1983-01-01

    Platelet scintigraphy was performed on 62 patients with cerebral ischaemia. Pathological scintigraphic images were obtained in 29 of the 62 patients. In 79.3% of these 29 patients the scan was abnormal in the vessel clinically affected. Platelet scintigraphy was abnormal in 21 of 34 patients with normal angiogram or only slight atherosclerosis. In patients undergoing antiplatelet therapy, platelet scintigraphy was less often positive than in untreated patients. It is suggested that platelet scintigraphy could be an appropriate technique for detecting small mural thrombi of the carotid artery, which are the source of arterio-arterial emboli, and for controlling the efficiency of antiplatelet therapy. (orig.) [de

  8. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  9. Bone scintigraphy in psoriasis

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, K.; Thiers, G.; Eissner, D.; Holzmann, H.

    1980-08-01

    Since 1973 bone scintigraphy using sup(99m)Tc-phosphate-complexes was carried out in 382 patients with psoriasis. For comparison with the results of nuclear medicine, roentgenologic and clinical findings a group af 121 patients with psoriasis aged between 11 and 74 years was compared to a group of 42 patients aged between 20 and 49 years without roentgenologic and clinical signs of psoriasis arthritis. We found by means of isotope investigation that an essentially greater part of the bones adjacent to the joints was involved than was expected according to X-ray and clinical findings. In addition, in 205 patients with psoriasis whole-body scintigraphy, using sup(99m)Tc-MDP, was carried out since 1977/78. In 17 patients we found an increased accumulation of activity in the region of extraarticular structures of the skull as well as of the skeletal thorax. According to these results we conclude that in addition to the clinically and roentgenologically defined psoriatic arthritis in patients with psoriasis an osteopathy may exist, which can only be demonstrated by skeletal scintigraphy and which is localized in bones adjacent to the joints but can also be demonstrated in the region of extraarticular bones.

  10. Selective coronary scintigraphy

    International Nuclear Information System (INIS)

    Gambini, D.-J.

    1975-01-01

    Isotopic techniques occupy a leading place amongst examinations practicable on coronary patients because of their reliability and the safety and simplicity of their use. The present work reviews the possible applications of selective coronary scintigraphy in pathology. After a brief discussion on scintigraphy, isotopic techniques for myocardium research, coronarography and other methods to study local myocardium perfusion the theoretical bases for the use of the exploration are studied, the techniques and methods employed are reported and the results discussed. Coronary scintigraphy consists of selective injection in the two coronary arteries previously catheterized during a coronarography, of two different populations of microspheres labelled with two physically short-lived indicators: 15μ 99m Tc-labelled serumalbumin microspheres, 10 to 15μ In-labelled siderophiline microspheres. Various studies have shown the complete harmlessness of the exploration when certain precautions are taken regarding the size and number of the spheres. The microspheres disperse into the downstream arterial territory proportionally to the number of capillaries present in the different parts of the irrigated region, and are temporarily stopped in the precapillaries. The preparation of the different images needed to interpret the Face and OAG examination for the left coronary, then for the right coronary, is carried out at the end of the coronarography and lasts about 45 minutes. It is also possible by selective injection in the aorta-coronary bridges to judge their functional condition by observation of the regions they irrigate. 56 patients of the Necker hospital cardiological clinic have been examined [fr

  11. Bone scintigraphy in psoriasis

    International Nuclear Information System (INIS)

    Hahn, K.; Thiers, G.; Eissner, D.; Holzmann, H.; Frankfurt Univ.

    1980-01-01

    Since 1973 bone scintigraphy using sup(99m)Tc-phosphate-complexes was carried out in 382 patients with psoriasis. For comparison with the results of nuclear medicine, roentgenologic and clinical findings a group af 121 patients with psoriasis aged between 11 and 74 years was compared to a group of 42 patients aged between 20 and 49 years without roentgenologic and clinical signs of psoriasis arthritis. We found by means of isotope investigation that an essentially greater part of the bones adjacent to the joints was involved than was expected according to X-ray and clinical findings. In addition, in 205 patients with psoriasis whole-body scintigraphy, using sup(99m)Tc-MDP, was carried out since 1977/78. In 17 patients we found an increased accumulation of activity in the region of extraarticular structures of the skull as well as of the skeletal thorax. According to these results we conclude that in addition to the clinically and roentgenologically defined psoriatic arthritis in patients with psoriasis an osteopathy may exist, which can only be demonstrated by skeletal scintigraphy and which is localized in bones adjacent to the joints but can also be demonstrated in the region of extraarticular bones. (orig.) [de

  12. Bone- and bone marrow scintigraphy in Gaucher disease type 1

    International Nuclear Information System (INIS)

    Mikosch, P.; Zitter, F.; Gallowitsch, H.J.; Lind, P.; Wuertz, F.; Mehta, A.B.; Hughes, D.A.

    2008-01-01

    Scintigraphy is a method for imaging metabolism and should be viewed as complimentary to morphological imaging. Bone and bone marrow scintigraphy can particularly contribute to the detection of focal disease in Gaucher disease. In bone crises it can discriminate within three days after pain onset between local infection and aseptic necrosis. A further advantage of bone- and bone marrow scintigraphy is the visualization of the whole skeleton within one setting. Whole body imaging for focal lesions might thus be an objective in GD, in particular in patients complaining of several painful sites. Direct imaging of bone marrow deposits in GD by MIBI scintigraphy might be of special interest in children in whom bone marrow undergoes a developmental conversion from red to yellow marrow in the ap-pendicular skeleton. MRI interpretation in young GD patients is thus difficult in order to estimate the exact amount and extent of bone marrow infiltration by Gaucher cells. 99mTc-MIBI scintigraphy with its direct visualization of lipid storage could thus add interesting additional information not shown with other methods including MRI. Although MRI is the most accepted imaging modality in assessing the skeletal status in GD, a selective use of scintigraphy for imaging bone and bone marrow may add information in the evaluation of patients with Gaucher disease

  13. The possibility of evaluation on inflammatory change at respiratory tract in chronic bronchial asthma using 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Uchiyama, Mayuki; Mori, Yutaka; Kawakami, Kenji; Kikuchi, Ichiro; Shimada, Takao.

    1997-01-01

    67 Ga scintigraphy was performed in 17 patients with chronic bronchial asthma to grasp the inflammatory change of respiratory tract. On 67 Ga scintigraphy, abnormal accumulations were detected on lung fields in 6 cases (35.3%) of 17 cases. In 5 cases of these 6 cases, the defect areas which were pointed out on 81m Kr ventilation scintigraphy were matched to the abnormal accumulation areas which were pointed out on 67 Ga scintigraphy. In dynamics, the abnormal accumulation areas which were pointed out on 67 Ga scintigraphy were matched to the defect areas which had been at all times pointed out on 81m Kr ventilation scintigraphy. 67 Ga scintigraphy was expected to be one of index to grasp the inflammatory change of respiratory tract in patients with chronic bronchial asthma. (author)

  14. Detection of activities of daily living impairment in Alzheimer's disease and mild cognitive impairment using information and communication technology

    Directory of Open Access Journals (Sweden)

    Sacco G

    2012-12-01

    Full Text Available Guillaume Sacco,1–3 Véronique Joumier,1,4 Nelly Darmon,1 Arnaud Dechamps,1,5 Alexandre Derreumaux,1,3 Ji-Hyun Lee,2 Julie Piano,2 Nathalie Bordone,2 Alexandra Konig,1,6 Bernard Teboul,3 Renaud David,1,2 Olivier Guerin,1,3 François Bremond,1,4 Philippe Robert1,21EA CoBTeK, Université de Nice Sophia-Antipolis, 2Centre Mémoire de Ressource et de Recherche, CHU de Nice, 3Plateforme Patient du Centre d'Innovation et d'Usage en Santé, CHU de Nice, 4Equipe Stars, Institut National de Recherche en Informatique et en Automatique (INRIA, Sophia-Antipolis, France; 5University of Pancasila, Department of Psychology, Jakarta, Indonesia; 6University of Maastricht, Faculty of Psychology and Neuropsychology, Department of Psychiatry and Neuropsychology, Maastricht, The NetherlandsBackground: One of the key clinical features of Alzheimer's disease (AD is impairment in daily functioning. Patients with mild cognitive impairment (MCI also commonly have mild problems performing complex tasks. Information and communication technology (ICT, particularly techniques involving imaging and video processing, is of interest in order to improve assessment. The overall aim of this study is to demonstrate that it is possible using a video monitoring system to obtain a quantifiable assessment of instrumental activities of daily living (IADLs in AD and in MCI.Methods: The aim of the study is to propose a daily activity scenario (DAS score that detects functional impairment using ICTs in AD and MCI compared with normal control group (NC. Sixty-four participants over 65 years old were included: 16 AD matched with 10 NC for protocol 1 (P1 and 19 MCI matched with 19 NC for protocol 2 (P2. Each participant was asked to undertake a set of daily tasks in the setting of a “smart home” equipped with two video cameras and everyday objects for use in activities of daily living (8 IADLs for P1 and 11 for P2, plus 4 temporal execution constraints. The DAS score was then computed

  15. Value of bone scintigraphy in psoriasis

    International Nuclear Information System (INIS)

    Nakayama, Chikashi; Nakata, Hajime; Kimoto, Tatsuya; Nakayama, Takashi; Yokomizo, Yu

    1982-01-01

    We performed bone scintigraphy on 16 cases of psoriasis to evaluate its possible value in this disease and obtained the following results: 1) Bone scintigraph was abnormal in 15 of 16 cases and the frequent association of arthritis in psoriasis was confirmed. 2) Abnormal uptake on bone scintigraph was noted in various joints including peripheral joints of extremities, sternoclavicular joint, shoulder and rib. Abnormality of sacroiliac joint or ankle was less frequent than previously reported. 3) Findings of bone scintigraph were not necessarily related with clinical symptoms or laboratory data. Abnormal uptake was also noted in many joints whose X-ray examinations were negative. Bone scintigraphy thus seems to be useful in early detection of arthritis and to become an initial therapeutic indicator of arthritis in psoriasis. (author)

  16. Esophageal transit scintigraphy in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Marek Chojnowski

    2016-11-01

    Full Text Available Systemic sclerosis is a rare connective tissue disease, distinctive features of which are fibrosis and microangiopathy. The esophagus is one of the most commonly involved internal organs. Most patients experience dysphagia, difficulties in swallowing and gastro-esophageal reflux. However, in up to one third of cases, the initial onset of esophageal disease may be clinically silent. There are several diagnostic modalities available for assessing both morphological and functional abnormalities of the esophagus. If structural abnormalities are suspected, endoscopy is the method of choice. Functional evaluation is best achieved with manometry. Both endoscopy and manometry are invasive techniques, with low patient acceptance. Barium-contrast study is well tolerated, but qualitative assessment of functional abnormalities is imprecise. Esophageal scintigraphy is an easy, non-invasive, sensitive and specific diagnostic modality. It can detect esophageal dysfunction even in asymptomatic patients. In patients already diagnosed with systemic sclerosis, scintigraphy is useful in evaluating severity and progression of the disease.

  17. New agents for scintigraphy in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Bois, M.H.W. de; Pauwels, E.K.J.; Breedveld, F.C.

    1995-01-01

    Radiopharmaceuticals have been used as investigative tools for the detection and treatment of arthritis activity in rheumatoid arthritis (RA) since the 1950s. Against the background of the pathophysiology of RA, the current status of joint scintigraphy and possible future developments are reviewed. Both non-specific (radiolabelled leucocytes and technetium-99m labelled human immunoglobulin) and specific targeting radiopharmaceuticals (including radiolabelled antibodies) are considered. The use of radiopharmaceuticals in the detection of arthritis activity has the advantages of allowing direct imaging of joints by means of whole-body scintigraphy and of joints that are difficult to assess clinically or radiographically. Promising results have been obtained with radiolabelled anti-CD4 and anti-E-selectin antibodies and with somatostatin receptor imaging, but more data are available regarding 99m Tc-IgG scintigraphy, which differentiates between the various degrees of arthritis activity and thus facilitates the choice of antirheumatic drug. Newer promising approaches to the imaging of RA include the use of radiolabelled J001 and cytokines, though studies on these are limited at present. (orig.)

  18. Early detection and monitoring of cartilage alteration in the experimental meniscectomised guinea pig model of osteoarthritis by 99mTc-NTP 15-5 scintigraphy

    International Nuclear Information System (INIS)

    Miot-Noirault, Elisabeth; Vidal, Aurelien; Bonafous, Jacques; Audin, Laurent; Madelmont, Jean-Claude; Moins, Nicole; Pastoureau, Philippe; Chomel, Agnes; Sarry, Laurent

    2007-01-01

    This study in the meniscectomised guinea pig aimed to demonstrate that the radiotracer 99m Tc-NTP 15-5 would have pathophysiological validity for in vivo osteoarthritis imaging. The specificity of 99m Tc-NTP 15-5 for cartilage was determined in healthy animals (n = 13), by tissue radioactivity counting, joint autoradiography and scintigraphy. 99m Tc-NTP 15-5 scintigraphy was performed at 20, 50, 80, 115, 130, 150 and 180 days after medial meniscectomy (n = 10 MNX) or sham operation (n = 5), and scintigraphic ratios (operated/contralateral) were calculated for femoral (F) and tibial (T) areas. F and T ratios were compared with those of 99m Tc-MDP bone scintigraphy. At the study end-point, autoradiographic analysis of joint 99m Tc-NTP 15-5 distribution and macroscopic scoring of cartilage integrity were performed. The high and specific accumulation of 99m Tc-NTP 15-5 in normal cartilage (about 5.5 ± 1.7 % of injected dose/g of tissue), which permitted joint imaging with high contrast, was affected by osteoarthritis. In the MNX group, 99m Tc-NTP 15-5 accumulation in cartilage within the operated joint, relative to the contralateral joint, was observed to change in the same animals as pathology progressed. Although F and T ratios were significantly higher in MNX (F = 1.7 ± 0.2; T = 1.6 ± 0.1) than in shams (F = 1.0 ± 0.1; T = 1.0 ± 0.1) at day 50, they were significantly lower in MNX (F = 0.6 ± 0.1; T = 0.7 ± 0.1) than in shams (F = 1.0 ± 0.1; T = 0.9 ± 0.1) at day 180. No change in 99m Tc-MDP uptake was observed over 6 months. Macroscopic analysis confirmed features of osteoarthritis only in MNX knees. These results in MNX guinea pigs provide additional support for the use of 99m Tc-NTP 15-5 for in vivo imaging of osteoarthritis. (orig.)

  19. Early detection and monitoring of cartilage alteration in the experimental meniscectomised guinea pig model of osteoarthritis by {sup 99m}Tc-NTP 15-5 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Miot-Noirault, Elisabeth; Vidal, Aurelien; Bonafous, Jacques; Audin, Laurent; Madelmont, Jean-Claude; Moins, Nicole [UMR 484 INSERM, Rue Montalembert, BP 184, Clermont-Ferrand Cedex (France); Pastoureau, Philippe; Chomel, Agnes [Institut de Recherches Servier, Suresnes (France); Sarry, Laurent [ERI 14 INSERM - Faculte de Medecine, Clermont-Ferrand (France)

    2007-08-15

    This study in the meniscectomised guinea pig aimed to demonstrate that the radiotracer {sup 99m}Tc-NTP 15-5 would have pathophysiological validity for in vivo osteoarthritis imaging. The specificity of {sup 99m}Tc-NTP 15-5 for cartilage was determined in healthy animals (n = 13), by tissue radioactivity counting, joint autoradiography and scintigraphy. {sup 99m}Tc-NTP 15-5 scintigraphy was performed at 20, 50, 80, 115, 130, 150 and 180 days after medial meniscectomy (n = 10 MNX) or sham operation (n = 5), and scintigraphic ratios (operated/contralateral) were calculated for femoral (F) and tibial (T) areas. F and T ratios were compared with those of {sup 99m}Tc-MDP bone scintigraphy. At the study end-point, autoradiographic analysis of joint {sup 99m}Tc-NTP 15-5 distribution and macroscopic scoring of cartilage integrity were performed. The high and specific accumulation of {sup 99m}Tc-NTP 15-5 in normal cartilage (about 5.5 {+-} 1.7 % of injected dose/g of tissue), which permitted joint imaging with high contrast, was affected by osteoarthritis. In the MNX group, {sup 99m}Tc-NTP 15-5 accumulation in cartilage within the operated joint, relative to the contralateral joint, was observed to change in the same animals as pathology progressed. Although F and T ratios were significantly higher in MNX (F = 1.7 {+-} 0.2; T = 1.6 {+-} 0.1) than in shams (F = 1.0 {+-} 0.1; T = 1.0 {+-} 0.1) at day 50, they were significantly lower in MNX (F = 0.6 {+-} 0.1; T = 0.7 {+-} 0.1) than in shams (F = 1.0 {+-} 0.1; T = 0.9 {+-} 0.1) at day 180. No change in {sup 99m}Tc-MDP uptake was observed over 6 months. Macroscopic analysis confirmed features of osteoarthritis only in MNX knees. These results in MNX guinea pigs provide additional support for the use of {sup 99m}Tc-NTP 15-5 for in vivo imaging of osteoarthritis. (orig.)

  20. Hürthle cell tumor dwelling in hot thyroid nodules: preoperative detection with technetium-99m-MIBI dual-phase scintigraphy.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A; Lazzi, S

    1998-05-01

    Single injection dual-phase scintigraphy (early and late acquisitions) with 99mTc-MIBI was used to differentiate benign and malignant hot thyroid nodules. Thirteen euthyroid and two hyperthyroid patients displaying a hot thyroid nodule on the 99mTc scan due to an autonomously functioning thyroid nodule (AFTN) underwent early (15-30 min) and late (3-4 hr) thyroid scintigraphy after the administration of 740-1000 MBq 99mTc-MIBI. Visual scoring was done to assess nodular tracer uptake and retention. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late image and the washout rates (WO) from the nodule and thyroidal tissue were measured. All patients underwent thyroid surgery. Histopathology revealed a Hürthle cell tumor in three nodules, a benign adenoma with oxyphilic metaplasia in two nodules and a benign adenoma without oxyphilic cells in the remaining 10 nodules. The Hürthle cell tumor nodules displayed intense and persistent uptake of 99mTc-MIBI (N/T was 2.81 +/- 0.52 and 5.53 +/- 1.06 in early and late images, respectively; WO from the nodule was 12.33 +/- 0.47, WO from the thyroidal tissue was 22.00 +/- 3.56). The benign nodules showed intense uptake in the early image and intense uptake to absent retention in the late image (N/T was 2.94 +/- 1.31 and 1.62 +/- 0.50 in the early and late images, respectively; WO from the nodule was 20.25 +/- 2.92, WO from the thyroidal tissue was 20.33 +/- 2.92). Single injection dual-phase 99mTc-MIBI scintigraphy of the thyroid with AFTN can identify nodules as a result of the activity of a Hürthle cell tumor, since these tumors cause intense and persistent tracer uptake in contrast with a benign AFTN.

  1. Scintigraphy of parathyroids in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Hublo, D.; Beauchat, V.; Pattou, F.; Lecomte-Houcke, M.; Prangere, T.; Ziegels, P.; Carnaille, B.; Proye, C.; Marchandise, X.; Steiling, M.

    1997-01-01

    Use of pre-surgery imaging of parathyroids is still questioned. The goal of this study is to evaluate the sensitivity of the scintigraphy in the detection of secondary parathyroid anomalies with renal insufficiency. Thirty two patients (20 F, 12 M) of 14 - 74 years old were operated of secondary hyperparathyroidism with renal insufficiency. It was a matter of re-intervention in 9 cases. The acquisitions were achieved 20 min and 2 h after injection of 550 MBq of MIBI- 99m Tc or of Tetrofosmine - 99m Tc and 2 h after injection of 5.5 MBq of iodine 123. Eighty seven glands of 28 to 3820 mg were pulled out in 23 first surgeries while the parathyroid tissue was found in thymic prolongations in 5 of these patients. The masses of 41 glands, positive by scintigraphy (from 69 to 3829 mg), were significantly higher (Wilcoxon's test, p -8 ) than the 46 not-seen (from 28 to 1050 mg). The sensitivity of total detection is 47%, of 85% for the 33 glands of 500 mg or more and of 24% for the 54 glands of less than 500 mg. In 9 re-interventions, 12 abnormal glands were pulled out: 11 (of 430 to 4500 mg were positive by scintigraphy, while only one gland of 80 mg was not seen. In conclusion, the scintigraphy realised before first surgery for secondary hyperparathyroidism with renal insufficiency presents low sensitivity, related partly, at least, to the low mass of glands and justifies itself only by search for positive ectopic parathyroids. Instead, it appears performing and indispensable in case of re-intervention

  2. Accuracy of preoperative diagnosis for primary hyperparathyroidism by CT, US and scintigraphy

    International Nuclear Information System (INIS)

    Imada, Masanobu; Nonaka, Satoshi; Hayashi, Tatsuya; Kunibe, Isamu; Harabuchi, Yasuaki

    2003-01-01

    We determined the usefulness of computed tomography (CT), ultrasonography (US) and Tc-Tl subtraction scintigraphy for preoperative diagnosis in 12 patients with primary hyperparathyroidism, all of which were solitary adenoma. Seven (63.6%) of 11 tumors were detected by CT, 7 (58.3%) of 12 tumors were detected by US, and 7 (63.6%) of 11 tumors were detected by Tc-Tl subtraction scintigraphy. Of 7 tumors with size>10 mm, 6 (85.7%) were detected by CT, 5 (71.4%) were detected by US, and 6 (85.7%) were detected by Tc-Tl subtraction scintigraphy, whereas only 1 (25%) with a diameter of 10 mm was detected by each of CT or Tc-Tl subtraction scintigraphy and 2 (40%) with diameters 10 mm were detected by US. Of 6 tumors situated behind the thyroid gland or intra thyroid gland, 5 (83.3%) were detected by CT and all 6 (100%) were detected by US, Tl-Tc subtraction scintigraphy, which was employed for 5 tumors, detected all 5 (100%). However, in the tumors situated beneath the thyroid gland only 2 (40%) of 5, 1 (16.7%) of 6 and 2 (33.3%) of 6 were detected by CT, US and Tc-Tl subtraction scintigraphy respectively. In 5 tumors without thyroid disease, 4 (80%) of 5 were detected by both CT and US, 3 (75%) of 4 were detected by Tc-Tl subtraction scintigraphy. However, in 7 tumors with thyroid diseases (papillary carcinoma, follicular carcinoma, follicular adenoma, chronic thyroiditis, and adenomatous goiter), 3 (50%) of 6 were detected by CT, 3 (42.9%) of 7 were detected by US and 4 (57.1%) of 7 were detected by Tc-Tl subtraction scintigraphy. Location of tumor was the factor most likely to make appropriate diagnosis difficult for primary hyperparathyroidism by any assessment method. (author)

  3. Asymmetrically increased rib cage uptake on bone scintigraphy: Incidental detection of pleural mesothelioma on single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Dhull, Varun Singh; Sharma, Punit; Durgapal, Prashant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Follow-up bone scintigraphy (BS) in a patient of carcinoma left breast, who was treated with surgery followed by radiotherapy 12 years back, revealed asymmetrically increased radiotracer uptake in left-sided ribs. Since, this pattern was atypical for metastatic rib involvement, single photon emission computed tomography/computed tomography (SPECT/CT) of thorax was done in the same setting which revealed circumferential nodular left-sided pleural thickening. Biopsy confirmed it to be pleural mesothelioma. Left-sided ribs showed no abnormality on CT, thus suggesting the rib uptake as reactive in nature. This pattern of asymmetric rib uptake on BS should be kept in mind and warrants further investigation for determining underlying pathology

  4. Is there a place for radionuclide bone scintigraphy in the ...

    African Journals Online (AJOL)

    ... shown the importance of bone scintigraphy in the detection of fractures in radiographnegative skeletal trauma.T-3 The early detection and immobilisation of fractures of the scaphoid are thought to be essential in preventing the disabling sequelae of avascular necrosis and pseudo-arthrosis,4 Several studies allude to the

  5. Automatic quantitative renal scintigraphy

    International Nuclear Information System (INIS)

    Valeyre, J.; Deltour, G.; Delisle, M.J.; Bouchard, A.

    1976-01-01

    Renal scintigraphy data may be analyzed automatically by the use of a processing system coupled to an Anger camera (TRIDAC-MULTI 8 or CINE 200). The computing sequence is as follows: normalization of the images; background noise subtraction on both images; evaluation of mercury 197 uptake by the liver and spleen; calculation of the activity fractions on each kidney with respect to the injected dose, taking into account the kidney depth and the results referred to normal values; edition of the results. Automation minimizes the scattering parameters and by its simplification is a great asset in routine work [fr

  6. Gamma-scintigraphy

    International Nuclear Information System (INIS)

    Desgrez, H.A.

    1960-06-01

    Gamma-scintigraphy is a medical technique making it possible to fix the image of certain organs after the concentration in these of emitting radioactive products. It is already widely used in the case of the thyroid gland with iodine-132 by applying the isotope iodine 131. The study of the liver and gall bladder is carried out using colloidal gold 198 and Bengal pink marked with iodine 131. Serum albumin marked with iodine 131 makes it possible to study rachidian blockages. Other applications can already be foreseen in this direction. (author) [fr

  7. Novel fMRI working memory paradigm accurately detects cognitive impairment in Multiple Sclerosis

    Science.gov (United States)

    Nelson, Flavia; Akhtar, Mohammad A.; Zúñiga, Edward; Perez, Carlos A.; Hasan, Khader M.; Wilken, Jeffrey; Wolinsky, Jerry S.; Narayana, Ponnada A.; Steinberg, Joel L.

    2016-01-01

    Background Cognitive impairment (CI) cannot be diagnosed by MRI. Functional MRI (fMRI) paradigms such as the immediate/delayed memory task (I/DMT), detect varying degrees of working memory. Preliminary findings using I/DMT, showed differences in Blood Oxygenation Level Dependent (BOLD) activation between impaired (MSCI, n=12) and non-impaired (MSNI, n=9) MS patients. Objectives To confirm CI detection based on I/DMT’ BOLD activation in a larger cohort of MS patients. The role of T2 lesion volume (LV) and EDSS in magnitude of BOLD signal were also sought. Methods Fifty patients [EDSS mean (m) = 3.2, DD m =12 yr., age m =40yr.] underwent the Minimal Assessment of Cognitive Function in MS (MACFIMS) and the I/DMT. Working-memory activation (WMa) represents BOLD signal during DMT minus signal during IMT. CI was based on MACFIMS. Results 10 MSNI, 30 MSCI and 4 borderline patients were included in analyses. ANOVA showed MSNI had significantly greater WMa than MSCI, in the left (L) prefrontal cortex and L supplementary motor area (p = 0.032). Regression analysis showed significant inverse correlations between WMa and T2 LV/EDSS in similar areas (p = 0.005, 0.004 respectively). Conclusion I/DMT-based BOLD activation detects CI in MS, larger studies are needed to confirm these findings. PMID:27613119

  8. The diagnostic application of Ga-67 scintigraphy in primary lung cancer, hepatoma and abdominal abscess

    International Nuclear Information System (INIS)

    Oshiumi, Yoshihiko

    1983-01-01

    It is difficult to detect tumor lesions by 67 Gascintigraphy, though it is named as a tumor scintigraphy. Recently, 67 Ga-scintigraphy is well used in the detection of inflammatic lesions. This paper is to discuss the detectability of lesions and diagnostic limitation on operability by 67 Ga-scintigraphy to primary lung cancer, minute hepatoma and abdominal absccess. Primary lung cancer: In detecting metastatic hilar lymph nodes, the sensitivity is 54%, and the specificity is 78%. In detecting metastatic mediastinal lymph nodes, the sensitivity is 32% and the specificity is 89%. Minute hepatoma : The detectability depended on the size of the lesion. It is hard to detect lesions with under 2 cm by 67 Ga-scintigraphy. Abdominal abscess : The sensitivity is 88%, and the specificity is 92%. (author)

  9. Diagnostic application of Ga-67 scintigraphy in primary lung cancer, hepatoma and abdominal abscess. On surgical operation

    Energy Technology Data Exchange (ETDEWEB)

    Oshiumi, Yoshihiko (National Central Hospital of Fukuoka (Japan))

    1983-05-01

    It is difficult to detect tumor lesions by /sup 67/Ga-scintigraphy, though it is named as a tumor scintigraphy. Recently, /sup 67/Ga-scintigraphy is well used in the detection of inflammatic lesions. This paper is to discuss the detectability of lesions and diagnostic limitation on operability by /sup 67/Ga-scintigraphy to primary lung cancer, minute hepatoma and abdominal abscess. Primary lung cancer: In detecting metastatic hilar lymph nodes, the sensitivity is 54%, and the specificity is 78%. In detecting metastatic mediastinal lymph nodes, the sensitivity is 32% and the specificity is 89%. Minute hepatoma : The detectability depended on the size of the lesion. It is hard to detect lesions with under 2 cm by /sup 67/Ga-scintigraphy. Abdominal abscess : The sensitivity is 88%, and the specificity is 92%.

  10. Automatic Pedestrian Crossing Detection and Impairment Analysis Based on Mobile Mapping System

    Science.gov (United States)

    Liu, X.; Zhang, Y.; Li, Q.

    2017-09-01

    Pedestrian crossing, as an important part of transportation infrastructures, serves to secure pedestrians' lives and possessions and keep traffic flow in order. As a prominent feature in the street scene, detection of pedestrian crossing contributes to 3D road marking reconstruction and diminishing the adverse impact of outliers in 3D street scene reconstruction. Since pedestrian crossing is subject to wearing and tearing from heavy traffic flow, it is of great imperative to monitor its status quo. On this account, an approach of automatic pedestrian crossing detection using images from vehicle-based Mobile Mapping System is put forward and its defilement and impairment are analyzed in this paper. Firstly, pedestrian crossing classifier is trained with low recall rate. Then initial detections are refined by utilizing projection filtering, contour information analysis, and monocular vision. Finally, a pedestrian crossing detection and analysis system with high recall rate, precision and robustness will be achieved. This system works for pedestrian crossing detection under different situations and light conditions. It can recognize defiled and impaired crossings automatically in the meanwhile, which facilitates monitoring and maintenance of traffic facilities, so as to reduce potential traffic safety problems and secure lives and property.

  11. AUTOMATIC PEDESTRIAN CROSSING DETECTION AND IMPAIRMENT ANALYSIS BASED ON MOBILE MAPPING SYSTEM

    Directory of Open Access Journals (Sweden)

    X. Liu

    2017-09-01

    Full Text Available Pedestrian crossing, as an important part of transportation infrastructures, serves to secure pedestrians’ lives and possessions and keep traffic flow in order. As a prominent feature in the street scene, detection of pedestrian crossing contributes to 3D road marking reconstruction and diminishing the adverse impact of outliers in 3D street scene reconstruction. Since pedestrian crossing is subject to wearing and tearing from heavy traffic flow, it is of great imperative to monitor its status quo. On this account, an approach of automatic pedestrian crossing detection using images from vehicle-based Mobile Mapping System is put forward and its defilement and impairment are analyzed in this paper. Firstly, pedestrian crossing classifier is trained with low recall rate. Then initial detections are refined by utilizing projection filtering, contour information analysis, and monocular vision. Finally, a pedestrian crossing detection and analysis system with high recall rate, precision and robustness will be achieved. This system works for pedestrian crossing detection under different situations and light conditions. It can recognize defiled and impaired crossings automatically in the meanwhile, which facilitates monitoring and maintenance of traffic facilities, so as to reduce potential traffic safety problems and secure lives and property.

  12. Tc99m-pertechnetate thyroid scintigraphy in newborns with neonatal TSH levels > 20uUI/ml, detected in the national program of newborn screening of congenital hypothyroidism (CH)

    International Nuclear Information System (INIS)

    Lobo, G.; Ladron de Guevara, D.; Perez, A.; Donoso, G.; Jimenez, C.; Arnello, F.; Vivanco, X.

    2002-01-01

    The aim of this study was to analyse the thyroid scintigraphy (TS) findings in 279 newborn with neonatal TSH (TSHnn) levels above 20 uUI/ml, detected in the national program of newborn screening of CH and phenylketonuria, and to compare them with: 1) final diagnosis, estimating its positive (PPV) and negative predictive value (NPV) and 2) TSHnn levels. Materials and Method: Thyroid scintigraphy of 279 newborn (57.3% girls) who presented TSHnn levels > 20 uUI/ml were revised, classifying them in eutopic gland (EuG), ectopic gland (EcG) and absence of contrast (AC). EuG was classified by visual and quantitative criteria in: normal contrast and size, goiter, and decreased contrast (DC). Tc99m-pertechnetate TS was performed average at 19th life's day (SD:11 days) with a gammacamera- computer system. The patients were separated according to hormonal confirmatory levels in: CH, hyperthyrotropinaemia (HT) and euthyroid. We compared TS results with final diagnosis and also with TSHnn levels (>= or 50 uUI/ml group (p<0.001). Moreover, the former group presented bigger proportion of CH newborns and of EcG scans than < 50uUI/ml patients (p<0.001). EcG and goiter condition had a PPV for CH of 100% and 79.6%, respectively. The NPV of normal TS was 86.7%. Conclusion: 1) Newborns with TSHnn levels larger than 20 uUI/ml show a high frequency of abnormal TS. 2) The EcG is highly predictive of CH. 3) Goiter and AC associated to TSHnn levels above 50 uUI/ml support strongly CH diagnosis. 4) Normal TS correspond very likely to euthyroid newborn, specially when TSHnn is lower than 50 uUI/ml

  13. Scintigraphy with In-111 labeled leukocytes

    International Nuclear Information System (INIS)

    Itoh, Kazuo; Tsukamoto, Eriko; Furudate, Masayori; Saito, Chihoko.

    1987-01-01

    With increasing necessity for In-111 labeled leukocyte scintigraphy (ILLS) as a routine examination, a problem of complicated labeling of leukocytes has arisen. In this study, simplified labeling of leukocytes was examined with respect to its ability to detect abscesses. Simplified labeling method yielded significantly satisfactory results for recovery and labeling rates of leukocytes, as compared with conventional recommended method. Therefore, ILLS by simplified technique was clinically applied in 58 patients with suppurative or non-suppurative diseases who gave informed consent. In an analysis of ILLS for detecting suppurative region, the sensitivity, specificity, and corrected specificity were found to be 81 %, 75 %, and 82 %, respectively. (Namekawa, K.)

  14. Aerosol lung inhalation scintigraphy in normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Sui, Osamu; Shimazu, Hideki

    1985-03-01

    We previously reported basic and clinical evaluation of aerosol lung inhalation scintigraphy with /sup 99m/Tc-millimicrosphere albumin (milli MISA) and concluded aerosol inhalation scintigraphy with /sup 99m/Tc-milli MISA was useful for routine examination. But central airway deposit of aerosol particles was found in not only the patients with chronic obstructive pulmonary disease (COPD) but also normal subjects. So we performed aerosol inhalation scintigraphy in normal subjects and evaluated their scintigrams. The subjects had normal values of FEVsub(1.0)% (more than 70%) in lung function tests, no abnormal findings in chest X-ray films and no symptoms and signs. The findings of aerosol inhalation scintigrams in them were classified into 3 patterns; type I: homogeneous distribution without central airway deposit, type II: homogeneous distribution with central airway deposit, type III: inhomogeneous distribution. These patterns were compared with lung function tests. There was no significant correlation between type I and type II in lung function tests. Type III was different from type I and type II in inhomogeneous distribution. This finding showed no correlation with %VC, FEVsub(1.0)%, MMF, V radical50 and V radical50/V radical25, but good correlation with V radical25 in a maximum forced expiratory flow-volume curve. Flow-volume curve is one of the sensitive methods in early detection of COPD, so inhomogeneous distribution of type III is considered to be due to small airway dysfunction.

  15. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake and others

    1988-12-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69+-0.48 to 0.11+-0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07+-1.03) were not significantly different from those at the first scintigraphy (1.13+-0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy.

  16. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    International Nuclear Information System (INIS)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake

    1988-01-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69±0.48 to 0.11±0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07±1.03) were not significantly different from those at the first scintigraphy (1.13±0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy. (author)

  17. AIDS-related Kaposi sarcoma: findings on thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Lee, V.W.; Rosen, M.P.; Baum, A.; Cohen, S.E.; Cooley, T.P.; Liebman, H.A.

    1988-01-01

    No simple, noninvasive method is available for evaluating extracutaneous Kaposi sarcoma in AIDS patients or for following the tumor's response to treatment. We report our preliminary experience with thallium-201 scintigraphy in nine AIDS patients with proved Kaposi sarcoma. Eight of the nine had abnormal uptake of the radionuclide in skin, lymph nodes, oral cavity, vagina, and lungs. Only four of the nine had cutaneous Kaposi sarcoma at the time of scanning. All cutaneous and mucosal lesions were thallium avid. Two of the six patients with thallium-avid nodes underwent nodal biopsy. Both biopsies confirmed the diagnosis of Kaposi sarcoma. Cutaneous Kaposi sarcoma developed later in one of these patients, showing the efficacy of thallium scintigraphy for the early detection of extracutaneous lesions. These preliminary results show thallium avidity in Kaposi sarcoma involving the skin and various extracutaneous sites (lymph nodes, lung, mucosa, and vagina). Thallium scintigraphy is a potentially useful procedure for detecting extracutaneous Kaposi sarcoma in AIDS patients

  18. Risk-benefit of dipyridamole loading thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Ueshima, Kenji; Ogiu, Naonori; Musha, Takehiko; Moriai, Naoki; Miyakawa, Tomohisa; Nakai, Kenji; Hiramori, Katsuhiko

    1995-01-01

    This study assessed the accuracy of dipyridamole-stressed thallium-201 scintigraphy in the detection of myocardial ischemia, as well as the associated complications and their background factors. Fifty consecutive patients (33 men and 17 women; a mean age of 67 years) unable to undergo exercise thallium imaging were examined. R waves on resting ECG, the occurrence of ischemic changes on exercise ECG, asynergy on left ventriculography and dobutamine-stressed two-dimensional echocardiography, uptake of FEG on PET, and coronary angiographic findings were comprehensively assessed to determine the accuracy of the present scintigraphy. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 60.4%, 94.2%, 89.7%, 83.0%, and 82.9%, respectively. These findings yielded satisfactory detectability of dipyridamole-stressed thallium-201 scintigraphy for myocardial ischemia. The present scintigraphy had a high sensitivity and specificity for the left anterior descending artery; however, it had a high specificity but low sensitivity for the other arteries. A majority of complications during the scintigraphy was transient, mild decrease in blood pressure, which was found especially when ischemia was present in the left circumflex artery and chest pain occurred during dipyridamole stress. Dipyridamole stress is considered to be contraindicated for patients with unstable angina. (N.K.)

  19. Psychomotor Impairment Detection via Finger Interactions with a Computer Keyboard During Natural Typing

    Science.gov (United States)

    Giancardo, L.; Sánchez-Ferro, A.; Butterworth, I.; Mendoza, C. S.; Hooker, J. M.

    2015-04-01

    Modern digital devices and appliances are capable of monitoring the timing of button presses, or finger interactions in general, with a sub-millisecond accuracy. However, the massive amount of high resolution temporal information that these devices could collect is currently being discarded. Multiple studies have shown that the act of pressing a button triggers well defined brain areas which are known to be affected by motor-compromised conditions. In this study, we demonstrate that the daily interaction with a computer keyboard can be employed as means to observe and potentially quantify psychomotor impairment. We induced a psychomotor impairment via a sleep inertia paradigm in 14 healthy subjects, which is detected by our classifier with an Area Under the ROC Curve (AUC) of 0.93/0.91. The detection relies on novel features derived from key-hold times acquired on standard computer keyboards during an uncontrolled typing task. These features correlate with the progression to psychomotor impairment (p < 0.001) regardless of the content and language of the text typed, and perform consistently with different keyboards. The ability to acquire longitudinal measurements of subtle motor changes from a digital device without altering its functionality may allow for early screening and follow-up of motor-compromised neurodegenerative conditions, psychological disorders or intoxication at a negligible cost in the general population.

  20. Unobtrusive Detection of Mild Cognitive Impairment in Older Adults Through Home Monitoring*

    Science.gov (United States)

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2016-01-01

    The early detection of dementias such as Alzheimer’s disease can in some cases reverse, stop or slow cognitive decline and in general greatly reduce the burden of care. This is of increasing significance as demographic studies are warning of an aging population in North America and worldwide. Various smart homes and systems have been developed to detect cognitive decline through continuous monitoring of high risk individuals. However, the majority of these smart homes and systems use a number of predefined heuristics to detect changes in cognition, which has been demonstrated to focus on the idiosyncratic nuances of the individual subjects and thus does not generalize. In this paper, we address this problem by building generalized linear models of home activity of subjects monitored using unobtrusive sensing technologies. We use inhomogenous Poisson processes to model the presence of subjects within different rooms throughout the day. We employ an information theoretic approach to compare the activity distributions learned, and we observe significant statistical differences between the cognitively intact and impaired subjects. Using a simple thresholding approach, we were able to detect mild cognitive impairment in older adults with an average area under the ROC curve of 0.716 and an average area under the precision-recall curve of 0.706 using distributions estimated over time windows of 12 weeks. PMID:26841424

  1. Unobtrusive Detection of Mild Cognitive Impairment in Older Adults Through Home Monitoring.

    Science.gov (United States)

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2017-03-01

    The early detection of dementias such as Alzheimer's disease can in some cases reverse, stop, or slow cognitive decline and in general greatly reduce the burden of care. This is of increasing significance as demographic studies are warning of an aging population in North America and worldwide. Various smart homes and systems have been developed to detect cognitive decline through continuous monitoring of high risk individuals. However, the majority of these smart homes and systems use a number of predefined heuristics to detect changes in cognition, which has been demonstrated to focus on the idiosyncratic nuances of the individual subjects, and thus, does not generalize. In this paper, we address this problem by building generalized linear models of home activity of older adults monitored using unobtrusive sensing technologies. We use inhomogenous Poisson processes to model the presence of the recruited older adults within different rooms throughout the day. We employ an information theoretic approach to compare the generalized linear models learned, and we observe significant statistical differences between the cognitively intact and impaired older adults. Using a simple thresholding approach, we were able to detect mild cognitive impairment in older adults with an average area under the ROC curve of 0.716 and an average area under the precision-recall curve of 0.706 using activity models estimated over a time window of 12 weeks.

  2. Detecting early egocentric and allocentric impairments deficits in Alzheimer's disease: an experimental study with virtual reality.

    Science.gov (United States)

    Serino, Silvia; Morganti, Francesca; Di Stefano, Fabio; Riva, Giuseppe

    2015-01-01

    Several studies have pointed out that egocentric and allocentric spatial impairments are one of the earliest manifestations of Alzheimer's Disease (AD). It is less clear how a break in the continuous interaction between these two representations may be a crucial marker to detect patients who are at risk to develop dementia. The main objective of this study is to compare the performances of participants suffering from amnestic mild cognitive impairment (aMCI group), patients with AD (AD group) and a control group (CG), using a virtual reality (VR)-based procedure for assessing the abilities in encoding, storing and syncing different spatial representations. In the first task, participants were required to indicate on a real map the position of the object they had memorized, while in the second task they were invited to retrieve its position from an empty version of the same virtual room, starting from a different position. The entire procedure was repeated across three different trials, depending on the object location in the encoding phase. Our finding showed that aMCI patients performed significantly more poorly in the third trial of the first task, showing a deficit in the ability to encode and store an allocentric viewpoint independent representation. On the other hand, AD patients performed significantly more poorly when compared to the CG in the second task, indicating a specific impairment in storing an allocentric viewpoint independent representation and then syncing it with the allocentric viewpoint dependent representation. Furthermore, data suggested that these impairments are not a product of generalized cognitive decline or of general decay in spatial abilities, but instead may reflect a selective deficit in the spatial organization Overall, these findings provide an initial insight into the cognitive underpinnings of amnestic impairment in aMCI and AD patient exploiting the potentiality of VR.

  3. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  4. The detection of gastro-oesophageal reflux in varicose changes of the oesophagus using scintigraphy. Szintigraphischer Nachweis des gastro-oesophagealen Refluxes bei Patienten mit Oesophagusvarizen

    Energy Technology Data Exchange (ETDEWEB)

    Kielmann, U.

    1984-08-27

    Comparative studies carried out in 22 bearers of oesophageal varices and 13 asymptomatic healthy volunteers on the basis of gastric reflux scintigraphy revealed findings to prove the occurrence of physiological reflux for the control group and, by contrast with this observation, markedly prolonged reflux episodes in the patient group. The occurrence of reflux was seen to be linked to the size of the varices found in the terminal oesophagus (negative correlation). A positive and significant correlation could be established between the size of a patient's varices and the frequency of haemorrhages. Bleedings and reflux episodes, however, were observed to be quite unrelated events. The results obtained strongly suggested that gastro-oesophageal reflux cannot be regarded as having a key role in haemorrhages from oesophageal varices. Nor was it possible to find statistical support for the effects of sclerotherapy on the frequency of haemorrhages. This was evidence in confirmation of the fact that obliteration is the obvious method in the treatment of haemorrhaging varices of the oesophagus. (TRV).

  5. RI scintigraphy in myasthenia gravis

    International Nuclear Information System (INIS)

    Kuroda, Yoshikazu; Miyamoto, Mariko; Maki, Masako; Yamazaki, Toshiro.

    1982-01-01

    35 cases of myasthenia gravis were studied with RI scintigraphy. 67 Ga-citrate was used in 34 patients and 76 Se-selenomethionine in 5 patients for thymus scintigraphy. RI scintigram was negative in non-tumorous thymus, regardless of the severity of illness and it was positive in seven of nine patients with thymomas. RI accumulation in thymus was found both in benign and malignant thymomas. RI seems to accumulated in lymphocytic and mixed thymus more than epithelial type. (author)

  6. RI scintigraphy in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Yoshikazu; Miyamoto, Mariko (Tokyo Metropolitan Fuchu Hospital (Japan)); Maki, Masako; Yamazaki, Toshiro

    1982-10-01

    35 cases of myasthenia gravis were studied with RI scintigraphy. /sup 67/Ga-citrate was used in 34 patients and /sup 76/Se-selenomethionine in 5 patients for thymus scintigraphy. RI scintigram was negative in non-tumorous thymus, regardless of the severity of illness and it was positive in seven of nine patients with thymomas. RI accumulation in thymus was found both in benign and malignant thymomas. RI seems to accumulated in lymphocytic and mixed thymus more than epithelial type.

  7. Dynamic esophageal scintigraphy

    International Nuclear Information System (INIS)

    Reilley, J.J.; Malmud, L.S.; Fisher, R.S.; Applegate, G.; DeVegvar, M.L.

    1982-01-01

    Esophageal scintigraphy was developed in order to quantitatively evaluate esophageal transit in patients with a variety of esophageal disorders. The study is performed with orally administered technetium-99m sulfur colloid in water, using a gamma camera on-line to a digital computer. Esophageal transit is expressed as the percent emptying for each of the first 15-sec intervals for 10 min after an initial swallow and at 15-sec intervals after serial swallows. Esophageal transit is significantly decreased in patients with motor disorders of the esophagus, compared to normal controls. In patients with reflux esophagitis, esophageal transit was abnormal when the reflux disease was accompanied by abnormal motor function. The technique we describe is the first quantitative test of esophageal function; it is a useful, sensitive, scintigraphic technique for evaluation of esophageal transit

  8. Apparatus for hybid scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Roux, G

    1975-07-17

    The hybrid scintigraphy device allows scintigrams to be recorded of the whole body in one single scan made parallel to the body. A single rod shaped sodium iodide crystal is used. One of its longitudinal faces is plane and transparent and is in optical contact with a transparent protection plate. The other longitudinal faces are dulled and coated with a light scattering layer of MgO or Al/sub 2/O/sub 3/. On one side of the crystal a collimator is installed for the incident gamma or X-radiation, on the transparent side there are a number of photomultipliers. They are optically coupled with the surface of the crystal by means of an interconnected light conductor. The outputs of the photomultipliers are combined with each other in resistance networks, summers or subtracters and a delay network and electronic circuits for time measurement, respectively.

  9. Novel fMRI working memory paradigm accurately detects cognitive impairment in multiple sclerosis.

    Science.gov (United States)

    Nelson, Flavia; Akhtar, Mohammad A; Zúñiga, Edward; Perez, Carlos A; Hasan, Khader M; Wilken, Jeffrey; Wolinsky, Jerry S; Narayana, Ponnada A; Steinberg, Joel L

    2017-05-01

    Cognitive impairment (CI) cannot be diagnosed by magnetic resonance imaging (MRI). Functional magnetic resonance imaging (fMRI) paradigms, such as the immediate/delayed memory task (I/DMT), detect varying degrees of working memory (WM). Preliminary findings using I/DMT showed differences in blood oxygenation level dependent (BOLD) activation between impaired (MSCI, n = 12) and non-impaired (MSNI, n = 9) multiple sclerosis (MS) patients. The aim of the study was to confirm CI detection based on I/DMT BOLD activation in a larger cohort of MS patients. The role of T2 lesion volume (LV) and Expanded Disability Status Scale (EDSS) in magnitude of BOLD signal was also sought. A total of 50 patients (EDSS mean ( m) = 3.2, disease duration (DD) m = 12 years, and age m = 40 years) underwent the Minimal Assessment of Cognitive Function in Multiple Sclerosis (MACFIMS) and I/DMT. Working memory activation (WMa) represents BOLD signal during DMT minus signal during IMT. CI was based on MACFIMS. A total of 10 MSNI, 30 MSCI, and 4 borderline patients were included in the analyses. Analysis of variance (ANOVA) showed MSNI had significantly greater WMa than MSCI, in the left prefrontal cortex and left supplementary motor area ( p = 0.032). Regression analysis showed significant inverse correlations between WMa and T2 LV/EDSS in similar areas ( p = 0.005, 0.004, respectively). I/DMT-based BOLD activation detects CI in MS. Larger studies are needed to confirm these findings.

  10. Clinical diagnostic potentials of thyroid ultrasonography and scintigraphy; An evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Torizuka, Tatsuo; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Konishi, Junji (Kyoto Univ. (Japan). Hospital); Endo, Keigo

    1993-06-01

    This prospective study was designed to evaluate the potential contributions of high resolution ultrasonography (US) and Tc-99m scintigraphy in the routine diagnosis of thyroid disease. The diagnostic impacts of US and Tc-99m scintigraphy results in 177 patients visiting our thyroid clinic were assessed and scored according to the following criteria: when the information provided by either test supported, confirmed or changed the initial clinical diagnosis, they received scores of 2, 3 and 4 respectively, while score 1 was given when the test itself was useless for the differential diagnosis. US identified focal lesions that both palpation and scintigraphy had failed to detect in 14 (12.1%) of 116 patients with diffuse thyroid diseases, suggesting the necessity of Hashimoto's thyroiditis, adenoma, adenocarcinoma and adenomatous goiter, and vice versa in the diagnosis of hyperthyroid and euthyroid Graves's diseases. Thus, the advantages of US over scintigraphy for morphological evaluation were confirmed. US was particularly useful for the differential diagnosis of adenomatous goiter from Hashimoto's thyroiditis or a single nodular disease. In contrast, scintigraphy gave functional images, being especially helpful for the differential diagnosis of thyrotoxicosis. (author).

  11. Availability of platelet scintigraphy for evaluation of arteriosclerosis obliterans

    International Nuclear Information System (INIS)

    Morimoto, Yoshihisa; Sugimoto, Takashi; Okada, Masayoshi; Mukai, Tomoichiro

    1998-01-01

    We reviewed the availability of platelet scintigraphy which can detect thrombotic activity to evaluate arteriosclerosis obliterans (ASO). During the past 13 months, 15 cases with ASO were studied. Among them, 6 cases (40%) showed acute aggravations of ischemic symptoms along with abnormal accumulation on scintigram. These cases have instantly more intensive antiplatelet and anticoagulant therapy, and obtained a remarkable recuperation together with disappearance of abnormal accumulation. In contrast, 9 cases without abnormal accumulation had a stable course without any ischemic complaints. In conclusion, platelet scintigraphy is very useful to evaluate the clinical effects of conservative or surgical therapy during the follow-up period in patients with ASO. (author)

  12. Analysis of liver blood flow by dynamic hepatic scintigraphy

    International Nuclear Information System (INIS)

    Xie Tianhao; Jia Shiquan

    1996-01-01

    Liver blood flow was studied in 45 patients with solitary malignant liver cancer, 17 patients with multiple liver metastases, 18 patients with benign liver tumor and 20 control subjects by dynamic hepatic scintigraphy. The hepatic perfusion index (HPI) in control subjects, patients with liver malignant cancer and benign tumor was 0.33 +- 0.069, 0.589 +- 0.084, 0.384 +-0.046 respectively, and the mesenteric fraction (MF) was 0.56 +- 0.054, 0.246 +- 0.064, 0.524 +- 0.086 respectively. In conclusion, flow scintigraphy is a non-invasive, sensitive and repeatable method for detection of liver tumor

  13. 99mTc-sucralfate scintigraphy in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Mortensen, P.B.; Lech, Y.; Moeller-Petersen, J.; Vilien, M.; Fallingborg, J.; Ekelund, S.

    1989-01-01

    Technetium-99m-labelled albumin-sucralfate was orally administered to 11 patients (Crohn's disease, 8; ulcerative colitis, 3) and 3 healthy volunteers. Serial scintigraphy was performed, and scintigraphic interpretations were compared with radiographic end endoscopic findings in an open study. It was not possible in any patient to relate the scintigraphic findings to the localizations of inflammatory bowel disease, nor was it possible to distinguish the scans in the patients from the scans of the healthy volunteers. It is concluded the 99m Tc-albumin-sucralfate scintigraphy is of no value in the detection of inflammatory bowel disease. 8 refs

  14. Myocardial scintigraphy with thallium-201

    International Nuclear Information System (INIS)

    Schwaiger, M.; Silber, S.; Klein, U.; Rudolph, W.

    1980-01-01

    Thallium-201 myocardial scintigraphy is an important non-invasive method for assessment of coronary artery disease. Other applications of the method such as delineation of the right ventricular free wall in right ventricular overload, or the detection of hypertrophic cardiomyopathies or myocardial infiltrations are of subordinate importance. In heart disease such as congestive cardiomyopathy and mitral valve prolapse thallium-201 uptake defects have been described, the clinical implications of these findings, however, cannot be adequately interpreted at this time. Myocardial uptake of thallium-201 is an active process, dependent on and proportional to perfusion. Differentiation between myocardial ischemia and myocardial scar is based on the presence or absence of thallium-201 'redistribution'. That is, in the presence of acute reversible ischemia there is increased thallium-201 uptake in the post-ischemic phase in previously hypoperfused myocardium and, subsequently, equilibrium of the initially registered activity differences. 'Redistribution' has also been described in the resting scintigram of patients with severe coronary artery disease and chronic hypoperfusion. (orig.) [de

  15. Functional scintigraphy of the thyroid

    International Nuclear Information System (INIS)

    Baehre, M.; Emrich, D.

    1983-01-01

    In order to obtain more diagnostic information by thyroid scintigraphy we used a gamma camera with a high resolution collimator and a computer. This led to an improvement of thyroid scintigrams and their documentation. Additionally it allowed to obtain values for global and regional uptake of pertechnetate before and under suppression. The usefulness of this method was proven by investigation of 50 individuals with normal thyroid function and 32 euthyroid patients with pathological suppressibility in an area of iodine deficiency. In normals global thyroid uptake and its suppression correlated with the FT 4 I and Δ TSH after TRH in dependence of their iodine excretion. Three types of pathological reaction under suppression could be delineated: 1. pure focal autonomy, 2. generalized (disseminated) autonomy, 3. combined focal and disseminated autonomy. The means of Δ TSH decreased stepwise from group 1 to 3 indicating increasing autonomy. The method is predominantly helpful to detect autonomy in euthyroid goitre. It is superior to qualitative evaluation of scintigrams. Additionally it is useful for decisions in therapy, especially for functionally orientated operation. (orig.) [de

  16. Sequential Scintigraphy in Renal Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Winkel, K. zum; Harbst, H.; Schenck, P.; Franz, H. E.; Ritz, E.; Roehl, L.; Ziegler, M.; Ammann, W.; Maier-Borst, W. [Institut Fuer Nuklearmedizin, Deutsches Krebsforschungszentrum, Heidelberg, Federal Republic of Germany (Germany)

    1969-05-15

    Based on experience gained from more than 1600 patients with proved or suspected kidney diseases and on results on extended studies with dogs, sequential scintigraphy was performed after renal transplantation in dogs. After intravenous injection of 500 {mu}Ci. {sup 131}I-Hippuran scintiphotos were taken during the first minute with an exposure time of 15 sec each and thereafter with an exposure of 2 min up to at least 16 min.. Several examinations were evaluated digitally. 26 examinations were performed on 11 dogs with homotransplanted kidneys. Immediately after transplantation the renal function was almost normal arid the bladder was filled in due time. At the beginning of rejection the initial uptake of radioactive Hippuran was reduced. The intrarenal transport became delayed; probably the renal extraction rate decreased. Corresponding to the development of an oedema in the transplant the uptake area increased in size. In cases of thrombosis of the main artery there was no evidence of any uptake of radioactivity in the transplant. Similar results were obtained in 41 examinations on 15 persons. Patients with postoperative anuria due to acute tubular necrosis showed still some uptake of radioactivity contrary to those with thrombosis of the renal artery, where no uptake was found. In cases of rejection the most frequent signs were a reduced initial uptake and a delayed intrarenal transport of radioactive Hippuran. Infarction could be detected by a reduced uptake in distinct areas of the transplant. (author)

  17. [The scintigraphy of somatostatin receptors in the carcinoid tumor].

    Science.gov (United States)

    Banzo, J; Abós, M D; Prats, E; Delgado , M; Razola, P; García, S; Gomollón, F; García, F

    2001-02-01

    This study aimed to evaluate the diagnostic utility of 111In-DTPA-D-Phe1-octreotide scintigraphy in the different situations that can be present when an examination is requested during the clinical course of the carcinoid tumor (CT). We have performed 41 scintigraphies with 111In-octreotide (145-185 MBq) in 35 patients (19 females and 16 males) with clinically suspected or confirmed CT. The patients were classified into five groups: Group A: Indolent symptoms of CT (n=9); B: CT staging located in lung (n=4), stomach (n=2), cecum (n=1), thymus (n=1) and pancreas (n=1); C: Carcinoid syndrome (n=1); D: CT staging after surgery located in pancreas (n=1), ovary (n=1), cecum (n=1), stomach (n=1), appendix (n=1) and ileum (n=1); and E: Post-treatment follow-up (n=13), with CT located in bronchial tree (n=5), small intestine (n=3), appendix (n=2), thymus (n=1), ovary (n=1) and unknown primary tumor (n=1). Three patients of this group had one scintigraphic study before the treatment. Head and neck, thorax and abdomen images were obtained at 4 and 24 h in all of the patients and SPECT images of the abdomen (n=14), thorax (n=10), and brain (n=1) were obtained at 24 h in 25 patients. Group A: In the 3 patients with a positive scintigraphy, the definitive diagnosis was meningioma, Hurtle cell's carcinoma and lung adenocarcinoma. The clinical follow-up in the six other patients, at least during one year, did not show any evidence of CT. Group B: Six of the 9 CT were detected with the scintigraphy. In 2 cases of bronchial CT, the scan showed sarcoidotic regional lymph node involvement and CT hepatic and bone metastases, respectively. Group C: The scintigraphy detected hepatic metastases from an unknown primary tumor. Group D: The scintigraphy was positive in 3 cases (hepatic or/and abdominal metastases) and was normal in the other 3. The scintigraphy was negative in one patient with peritoneal metastases. Group E: The scintigraphy was normal in 7 patients in concordance with the

  18. Dynamic scintigraphy of the kidneys with lasix

    International Nuclear Information System (INIS)

    Yudin, L.A.; Reznichenko, A.A.; Uskov, I.A.; Gol'dman, V.E.; Ivanova, Yu.V.; Naryshkina, V.M.; Budkevich, Yu.B.

    1991-01-01

    Dynamic scintigraphy with lasix in patients with hydronephrosis, nephrolithialis, chronic pyelonephritis, ureterohydronephrosis on an initial scintigram has shown retention of 99m Tc-DTPA in the urinary tracts: an increase or absence of the excretory segment on the activity-time curve up to the appearance of an obstructive type of a curve. Verified operative findings have shown a high sensitivity and accuracy of the detection of stenosis of the urinary tracts in the absence of the excretory segment on an initial scintigram irrespective of the reaction of lasix administration

  19. Studies on bone scintigraphy in renal osteodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchimochi, Makoto (Nippon Dental Univ., Niigata)

    1983-12-01

    Bone scintigraphy was superior over roentgenography for detection of abnormal bone findings in chronic dialysis patients. According to the type of scintigraphic findings, an increase in the hot area in the cranium or the mandibule seemed to express fibrous osteitis due to secondary hyperparathyroidism. Multiple coin-shaped hot areas in ribs were thought to indicate advanced osteomalacia or osteomalacia in patients with aluminum poisoning. The 4 hr-B/St ratio of the cranium was thought to serve as a quantitative indicator of the status of fibrous osteitis due to secondary hyperparathyroidism to show the progress and therapeutic course of the disease.

  20. Dual-phase 99mTc-MIBI scintigraphy with delayed neck and thorax SPECT/CT and bone scintigraphy in patients with primary hyperparathyroidism. Correlation with clinical or pathological variables

    International Nuclear Information System (INIS)

    Qiu, Zhongling; Shen, Chentian; Zhu, Ruisen; Luo, Quanyong; Wu, Bo

    2014-01-01

    The purpose of this study was to assess the relationship between 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy and clinical or pathological variables, including preoperative serum PTH levels and tumor diameter, in patients with newly diagnosed PHPT. Dual phase 99m Tc-MIBI planar scintigraphy was performed in 244 patients with PHPT. Of these patients, 155 underwent 99m Tc-MDP bone scintigraphy to detect bone changes before parathyroidectomy. Factors influencing 99m Tc-MIBI scintigraphy and 99m Tc-MDP bone scintigraphy detection rate were assessed using univariate and multivariate logistic regression analysis; optimal cutoff values for predicting positive 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy were evaluated using ROC analysis. Among 244 patients, 174 (71.31%) patients with 181 foci had a positive 99m Tc-MIBI planar scintigraphy; delayed neck and thorax SPECT/CT could identify and locate the 99m Tc-MIBI lesions but could not find more lesions than planar scintigraphy. 70 (28.69%) patients had a negative 99m Tc-MIBI planar scintigraphy. Tumor diameter, serum PTH level and symptoms were statistically significant predictive factors in predicting positive 9m Tc-MIBI scintigraphy both univariate and multivariate logistic regression analyses. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.03 cm and 127.60 ng/L, respectively. Among 155 patients with bone scintigraphy, 99m Tc-MDP bone scintigraphy showed positive finding in 80 (51.61%) patients and negative finding in 75 patients. Univariate logistic regression analysis showed that patient age, sex, tumor diameter and PTH level (≥150 ng/L) were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. Multivariate logistic regression analysis showed both tumor diameter and PTH ≥150 ng/L were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.96 cm and 163

  1. Value of renal cortical scintigraphy in children with acute pyelonephritis

    International Nuclear Information System (INIS)

    Paul, A.K.; Miah, M.S.R.; Rahman, H.A.; Hasan, M.H.

    2004-01-01

    Purpose: Acute pyelonephritis is a major cause of morbidity in children with urinary tract infection and can result in irreversible renal scarring leading to hypertension and end-stage renal disease. Tc-99m-dimercaptosuccinic acid (DMSA) scintigraphy is the imaging modality of choice for the detection of acute pyelonephhfis and renal scarfing. This study evaluated the importance of renal cortical scintigraphy to identify children at risk from renal damage due to acute pyelonephritis. Methods: Forty-nine children (ages 9 months to 11 years) with urinary tract infection having positive urine culture were studied. A DMSA scan was performed within 72 hours of receiving antibiotic during acute infection. Single or multiple areas of varying degrees of diminished cortical uptake or diffusely decreased uptake in an enlarged kidney was considered for the diagnosis of acute pyelonephrifis. Follow-up scintigraphy was done at 6 months of initial scan in children with acute pyelonephritis documented by DMSA scan. Renal scarring was considered if the affected kidney shows cortical thinning or focal cortical defect with loss of volume or become small kidney. Children with known renal tract abnormalities were excluded from the study. RESULTS: Twenty-seven children (55%) wine considered acute pyelonephritis by DMSA scintigraphy and the abnormality was bilateral in 17(63%) cases and unilateral in 10(37%) cases. Among these 44 abnormal kidneys, scintigraphy showed solitary defect in 29 kidneys, multiple defects in 6 kidneys and diffuse decreased uptake in 9 kidneys. Of them, twenty children were available for follow-up evaluation and scintigraphy demonstrated complete recovery in 21 of 34 (62%) kidneys and renal scarfing in 13 of 34 (38%) kidneys. Renal scarring was found in 5 of 7 kidneys (71%) with diffuse decreased uptake, 2 of 5 kidneys (40%) with multiple cortical defect and 6 of 22 (27%) with single focal detect. Conclusion: The scintigraphic pattern of acute pyelonephritis

  2. [Application scintigraphy in evaluation of salivary gland function].

    Science.gov (United States)

    Mojsak, Małgorzata Natalia; Rogowski, Franciszek

    2010-03-01

    The salivary glands belong to the exocrine glands. There are tree main pairs of salivary glands: parotid, submandibular, sublingual. Several modalities are used for salivary gland imaging, such as sonography, computer tomography and magnetic resonance imaging. The aim of these methods is mainly to present morphological impairment. Parenchymal function and excretion function of all salivary glands can be quantified by scintigraphy. After single intravenous injection of 99mTc-pertechnetate sequential images are acquired up to 25-40 minutes. Usually about fifteen minutes postinjection 3 ml of lemon juice are administered intraorally as sialogogue. Salivary scintigraphy can estimate the severity of salivary gland involvement and function disorders, which may not be accurately reflected by the morphological damage. The clinical impact of scintigraphy has been reported in multiple salivary glands diseases, such as Sjogren's syndrome, sialolithiasis with or without parenchymal damage, iatrogenic irradiation of the salivary glands for therapy of head and neck tumors or radioiodine treatment of thyroid cancer. No other method can give so much information about function of salivary glands. Scintigraphy is noninvasive examination, easy to perform, reproducible and well-tolerated by the patient.

  3. Diagnostic value of whole-body MRI and bone scintigraphy in the detection of osseous metastases in patients with breast cancer - a prospective double-blinded study at two hospital centers

    International Nuclear Information System (INIS)

    Ohlmann-Knafo, Susanne; Pickuth, D.; Kirschbaum, M.; Fenzl, G.

    2009-01-01

    The purpose of this study was to compare the diagnostic accuracy of whole-body MRI (WB-MRI) and bone scintigraphy (BS) for the screening of bone metastases for the first time in a large and homogeneous patient collective with breast cancer in a systematic and controlled study. 213 breast cancer patients were evaluated for bone metastases under randomized, double-blinded and prospective conditions at two hospitals. All participants were examined by WB-MRI and BS over an average period of four days. The examinations were performed separately at two different locations. The WB-MRI protocol included T 1-TSE and STIR sequences. WB-MRI and BS were reviewed independently by experienced radiologists and nuclear medicine specialists in a consensus reading. In 66 % of cases bone metastases were excluded by both procedures, and bone metastases were detected concordantly in 2 % of cases. In 7 % of cases there were discrepant results: in 7 cases BS was false-positive when WB-MRI was negative. In 5 / 7 cases BS was negative when WB-MRI identified bone metastases. In 89 % of cases BS was uncertain when WB-MRI was true-negative. In 17 % of cases WB-MRI showed important (non-) tumor-associated findings. The sensitivity, specificity, positive and negative predictive value and diagnostic accuracy for WB-MRI were 90 %, 94 %, 82 %, 98 % and 99 % and for BS those were 40 %, 81 %, 36 %, 91 % and 93 %. (orig.)

  4. Method of pancreas scintigraphy

    International Nuclear Information System (INIS)

    Michele, E.; Schmidt, H.A.E.

    1976-01-01

    Scintigraphy of the pancreas is important because of a lack of simple internal and x-ray pancreas diagnostic examination methods, non-burdening to the patient, yet providing sufficient evidence. We conceived a double isotope subtraction method aimed at widespread application; financially, it should be within the range even of smaller nuclear medicine departments. A scanner is combined with double impulse processing and a subtraction unit (Picker Dualscanner) and an adapted x-ray unit with the x-ray tube aimed at the scan-field. Commercial sup(Se-75)selenium methionine is used for pancreas imagining. sup(TC-99m)colloidal sulphur is used as a liver indicator. After barium-brei application orally, an x-ray is taken of the gastro-intestinal tract, so as to be able to delineate the pancreas from other epigastric organs also able to accumulate methionine. The subtraction photoscan is then inscribed on this pre-exposed film without any shift of the patient. It is also possible to use two parallel films (x-ray/photoscan) and then to superposition them

  5. Non-linear models for the detection of impaired cerebral blood flow autoregulation.

    Science.gov (United States)

    Chacón, Max; Jara, José Luis; Miranda, Rodrigo; Katsogridakis, Emmanuel; Panerai, Ronney B

    2018-01-01

    The ability to discriminate between normal and impaired dynamic cerebral autoregulation (CA), based on measurements of spontaneous fluctuations in arterial blood pressure (BP) and cerebral blood flow (CBF), has considerable clinical relevance. We studied 45 normal subjects at rest and under hypercapnia induced by breathing a mixture of carbon dioxide and air. Non-linear models with BP as input and CBF velocity (CBFV) as output, were implemented with support vector machines (SVM) using separate recordings for learning and validation. Dynamic SVM implementations used either moving average or autoregressive structures. The efficiency of dynamic CA was estimated from the model's derived CBFV response to a step change in BP as an autoregulation index for both linear and non-linear models. Non-linear models with recurrences (autoregressive) showed the best results, with CA indexes of 5.9 ± 1.5 in normocapnia, and 2.5 ± 1.2 for hypercapnia with an area under the receiver-operator curve of 0.955. The high performance achieved by non-linear SVM models to detect deterioration of dynamic CA should encourage further assessment of its applicability to clinical conditions where CA might be impaired.

  6. Network analysis in detection of early-stage mild cognitive impairment

    Science.gov (United States)

    Ni, Huangjing; Qin, Jiaolong; Zhou, Luping; Zhao, Zhigen; Wang, Jun; Hou, Fengzhen

    2017-07-01

    The detection and intervention for early-stage mild cognitive impairment (EMCI) is of vital importance However, the pathology of EMCI remains largely unknown, making it be challenge to the clinical diagnosis. In this paper, the resting-state functional magnetic resonance imaging (rs-fMRI) data derived from EMCI patients and normal controls are analyzed using the complex network theory. We construct the functional connectivity (FC) networks and employ the local false discovery rate approach to successfully detect the abnormal functional connectivities appeared in the EMCI patients. Our results demonstrate the abnormal functional connectivities have appeared in the EMCI patients, and the affected brain regions are mainly distributed in the frontal and temporal lobes In addition, to quantitatively characterize the statistical properties of FCs in the complex network, we herein employ the entropy of the degree distribution (EDD) index and some other well-established measures, i.e., clustering coefficient (CC) and the efficiency of graph (EG). Eventually, we found that the EDD index, better than the widely used CC and EG measures, may serve as an assistant and potential marker for the detection of EMCI.

  7. Impairments of mecA gene detection in bovine Staphylococcus spp.

    Directory of Open Access Journals (Sweden)

    Dayanne Araújo de Melo

    2014-09-01

    Full Text Available Staphylococcus aureus antimicrobial resistance, especially to beta-lactams, favors treatment failures and its persistence in herd environment. This work aimed to develop a more specific primer for mecA gene detection based on the comparison of the conserved regions from distinct host origins and also investigated the presence of homologue mecA LGA251 in bovine strains. A total of 43 Staphylococcus spp. were included in this study, comprising 38 bovine S. aureus, two human and three equine coagulase-negative staphylococci (CNS. Phenotypical methicillin-resistance detection was performed through oxacillin agar-screening and cefoxitin disk-diffusion test. None isolate tested positive for mecA LGA251 gene. For mecA gene PCR, new primers were designed based on the sequences of human S. aureus (HE681097 and bovine S. sciuri (AY820253 mecA. The new primers based on the S. aureus mecA sequence amplified fragments of human and equine CNS and the ones based on S. sciuri mecA sequence only yielded fragments for S. aureus bovine strains. Multiples alignments of mecA gene sequences from bovine, human and equine revealed punctual but significant differences in bovine strains that can lead to the mecA gene detection impairment. The observed divergences of mecA gene sequences are not a matter of animal or human origin, it is a specificity of bovine samples.

  8. Detection of illicit drugs in impaired driver saliva by a field-usable SERS analyzer

    Science.gov (United States)

    Shende, Chetan; Huang, Hermes; Farquharson, Stuart

    2014-05-01

    One of the greatest dangers of drug use is in combination with driving. According to the most recent National Highway Traffic Safety Administration (NHTSA) studies, more than 11% of drivers tested positive for illicit drugs, while 18% of drivers killed in accidents tested positive for illicit, prescription or over-the-counter drugs. Consequently, there is a need for a rapid, noninvasive, roadside drug testing device, similar to the breathalyzers used by law enforcement officials to estimate blood alcohol levels of impaired drivers. In an effort to satisfy this need we have been developing a sampling kit that allows extraction of drugs from 1 mL of saliva and detection by surfaceenhanced Raman spectroscopy using a portable Raman analyzer. Here we describe the development of the sampling kit and present measurements of diazepam at sub μg/mL concentrations measured in ~15 minutes.

  9. Use of stable helium tracer for the early detection of impaired pulmonary function

    International Nuclear Information System (INIS)

    Susskind, H.; Richards, P.; Atkins, H.L.

    1975-01-01

    Methodology and instrumentation are being developed to measure distal airway closure, a very sensitive diagnostic technique for the early detection of emphysema and other obstructive lung diseases and premature closure indicating abnormalities. The procedure is rapid and involves the inhalation of only a 1 ml bolus of readily available stable 4 He, continuous measurement of its concentration in the exhaled air with a helium leak detector type of mass spectrometer, and the subsequent analysis of the single-breath washout curve. Helium appears to be an ideal tracer, well-suited for testing in clinics and hospitals, as well as for epidemiological studies relating the effects of atmospheric pollutants and lung impairment and for screening of large populations for pulmonary dysfunction

  10. Scintigraphy of the cerebrospinal fluid

    International Nuclear Information System (INIS)

    Touya, E.; Perillo, W.; Paez, A.; Osorio, A.; Ferrando, R.; Lago, G.; Garcia Guelfi, A.; Ferrari, M.

    1977-01-01

    Eight years of experience in scintigraphy of cerebrospinal fluid (CSF) with 113 Insup(m)-colloid is reported. Two hundred cases are discussed. On the basis of the clinical diagnosis, the cases are divided into five groups: (1) spinal cord compression; (2) hydrocephalus of the adult and child; (3) control of extracranial CSF shunts; (4) CSF fistula; and (5) brain tumour. It is concluded that the radiopharmaceutical used has no limitations except in the study of the hydrocephalus of the adult. For those services remote from the production centres, it is a convenient option for CSF scintigraphy. (author)

  11. Skin autofluorescence based decision tree in detection of impaired glucose tolerance and diabetes.

    Directory of Open Access Journals (Sweden)

    Andries J Smit

    Full Text Available Diabetes (DM and impaired glucose tolerance (IGT detection are conventionally based on glycemic criteria. Skin autofluorescence (SAF is a noninvasive proxy of tissue accumulation of advanced glycation endproducts (AGE which are considered to be a carrier of glycometabolic memory. We compared SAF and a SAF-based decision tree (SAF-DM with fasting plasma glucose (FPG and HbA1c, and additionally with the Finnish Diabetes Risk Score (FINDRISC questionnaire±FPG for detection of oral glucose tolerance test (OGTT- or HbA1c-defined IGT and diabetes in intermediate risk persons.Participants had ≥1 metabolic syndrome criteria. They underwent an OGTT, HbA1c, SAF and FINDRISC, in adition to SAF-DM which includes SAF, age, BMI, and conditional questions on DM family history, antihypertensives, renal or cardiovascular disease events (CVE.218 persons, age 56 yr, 128M/90F, 97 with previous CVE, participated. With OGTT 28 had DM, 46 IGT, 41 impaired fasting glucose, 103 normal glucose tolerance. SAF alone revealed 23 false positives (FP, 34 false negatives (FN (sensitivity (S 68%; specificity (SP 86%. With SAF-DM, FP were reduced to 18, FN to 16 (5 with DM (S 82%; SP 89%. HbA1c scored 48 FP, 18 FN (S 80%; SP 75%. Using HbA1c-defined DM-IGT/suspicion ≥6%/42 mmol/mol, SAF-DM scored 33 FP, 24 FN (4 DM (S76%; SP72%, FPG 29 FP, 41 FN (S71%; SP80%. FINDRISC≥10 points as detection of HbA1c-based diabetes/suspicion scored 79 FP, 23 FN (S 69%; SP 45%.SAF-DM is superior to FPG and non-inferior to HbA1c to detect diabetes/IGT in intermediate-risk persons. SAF-DM's value for diabetes/IGT screening is further supported by its established performance in predicting diabetic complications.

  12. The value of scintigraphy in the evaluation of oropharyngeal dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Argon, Murat; Duygun, Uelkem; Kocacelebi, Kenan; Ozkilic, Hayal [Department of Nuclear Medicine, Ege University Medical School Hospital, 35100, Bornova, Izmir (Turkey); Secil, Yaprak; Aydogdu, Ibrahim; Ertekin, Cumhur [Department of Clinical Neurophysiology, Ege University Medical School Hospital, Izmir (Turkey)

    2004-01-01

    Healthy adults can swallow boluses of 20 ml water in a single swallow. Individuals with impaired swallowing, however, may be unable to do so, instead requiring two or more swallows; this phenomenon is called ''piecemeal deglutition''. The term ''dysphagia limit'' refers to the volume at which piecemeal deglutition occurs. The aim of our study was to investigate the potential value of scintigraphic evaluation of piecemeal deglutition and dysphagia limit in patients with dysphagia, based on correlation with the results of submental electromyography (SM-EMG) and laryngeal sensor monitoring (LS). The study population comprised 24 patients with dysphagia secondary to neurological disorders and ten normal adults, who formed a control group. In the scintigraphic evaluation, subjects underwent four separate dynamic studies using 5, 10, 15 and 20 ml of water containing 0.5 mCi technetium-99m labelled sulphur colloid, and time-activity curves (TACs) were created for each study. Static thoracic images were also recorded in order to detect airway aspiration Observation of two or more peaks on TACs within the 10-s acquisition period was considered a sign of piecemeal deglutition. If piecemeal deglutition occurred at or below 20 ml, this volume was regarded as the dysphagia limit. Piecemeal deglutition was not found in any normal subjects; by contrast, it was observed in 14 of the 24 (58%) patients on scintigraphy and in 17 (71%) patients on EMG and LS. In three patients, signs of the airway aspiration were observed on static thoracic images. Scintigraphic and electrophysiological findings were in agreement in 19 patients (79%), and the correlation between scintigraphy and the electrophysiological methods for the evaluation of dysphagia was statistically significant (r=0.57, P=0.003). The novel finding of this study is the demonstration of piecemeal deglutition and dysphagia limit on scintigraphic studies in patients with neurogenic

  13. The value of scintigraphy in the evaluation of oropharyngeal dysphagia

    International Nuclear Information System (INIS)

    Argon, Murat; Duygun, Uelkem; Kocacelebi, Kenan; Ozkilic, Hayal; Secil, Yaprak; Aydogdu, Ibrahim; Ertekin, Cumhur

    2004-01-01

    Healthy adults can swallow boluses of 20 ml water in a single swallow. Individuals with impaired swallowing, however, may be unable to do so, instead requiring two or more swallows; this phenomenon is called ''piecemeal deglutition''. The term ''dysphagia limit'' refers to the volume at which piecemeal deglutition occurs. The aim of our study was to investigate the potential value of scintigraphic evaluation of piecemeal deglutition and dysphagia limit in patients with dysphagia, based on correlation with the results of submental electromyography (SM-EMG) and laryngeal sensor monitoring (LS). The study population comprised 24 patients with dysphagia secondary to neurological disorders and ten normal adults, who formed a control group. In the scintigraphic evaluation, subjects underwent four separate dynamic studies using 5, 10, 15 and 20 ml of water containing 0.5 mCi technetium-99m labelled sulphur colloid, and time-activity curves (TACs) were created for each study. Static thoracic images were also recorded in order to detect airway aspiration Observation of two or more peaks on TACs within the 10-s acquisition period was considered a sign of piecemeal deglutition. If piecemeal deglutition occurred at or below 20 ml, this volume was regarded as the dysphagia limit. Piecemeal deglutition was not found in any normal subjects; by contrast, it was observed in 14 of the 24 (58%) patients on scintigraphy and in 17 (71%) patients on EMG and LS. In three patients, signs of the airway aspiration were observed on static thoracic images. Scintigraphic and electrophysiological findings were in agreement in 19 patients (79%), and the correlation between scintigraphy and the electrophysiological methods for the evaluation of dysphagia was statistically significant (r=0.57, P=0.003). The novel finding of this study is the demonstration of piecemeal deglutition and dysphagia limit on scintigraphic studies in patients with neurogenic dysphagia. Based on this finding we consider

  14. The role of DMSA renal scintigraphy in the first episode of urinary tract infection in childhood

    International Nuclear Information System (INIS)

    Supavekin, S.; Pravisithikul, N.; Kutanavanishapong, S.; Chiewvit, S.; Surapaitoolkorn, W.

    2013-01-01

    The role of dimercaptosuccinic acid (DMSA) renal scintigraphy in the first episode of urinary tract infection (UTI) has been the subject of debate for many years. The aim of this study was to evaluate the relationship of voiding cystourethrography (VCUG), renal ultrasonography and DMSA renal scintigraphy and to detect renal parenchymal changes by performing DMSA renal scintigraphy at 6 months after the first episode of UTI. A prospective study was conducted in 67 hospitalized children (46 boys, 21 girls). Mean age of the patients was 0.97±1.57 years (0.02-7.26 years). All children received VCUG, renal ultrasonography and DMSA renal scintigraphy. DMSA renal scintigraphy was performed at 1 and 6 months after UTI. Of 67 children, 17 (25.4%), 23 (34.3%) and 20 (29.9%) had vesicoureteral reflux (VUR), abnormal renal ultrasonography and abnormal DMSA renal scintigraphy, respectively. Unilateral hydronephrosis had a significant correlation with VUR at p value 0.024. In renal units, abnormal renal ultrasonography and hydronephrosis had significant correlations with VUR at p values 0.039 and 0.021, respectively. In patients and renal units, hydronephrosis had no significant correlation with abnormal DMSA renal scintigraphy at 1 month after UTI. However, abnormal renal ultrasonography and VUR had significant correlations with abnormal DMSA renal scintigraphy at p values 0.022 and <0.001 in patients and at p values 0.024 and <0.001 in renal units, respectively. Both in patients and renal units, VUR (Grade I-III) had no significant correlation with abnormal DMSA renal scintigraphy. However, severe VUR (Grade IV-V) had significant correlations with abnormal DMSA renal scintigraphy at p values <0.001 and <0.001, respectively. Seventeen patients underwent DMSA renal scintigraphy at 6 months after UTI. In addition, 15 (88.2%) developed persistent renal scarring. Abnormal renal ultrasonography and severe VUR identify renal parenchymal changes. DMSA renal scintigraphy in the first

  15. The role of Tl-201 total body scintigraphy in follow up of thyroid carcinoma

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Delprat, C.C.; Marcuse, H.R.

    1985-01-01

    To evaluate the reliability of the procedure T1-201 total body scintigraphy was performed in 294 patients (449 studies) after total thyroidectomy for thyroid carcinoma. Results were correlated with I-131-scintigraphy and tumor-marker levels (Tgb or Calcitonin/CEA). T1-201 total body scintigraphy was negative in 196 patients with no evidence of disease. T1-201-scintigraphy correctly detected tumor localizations in 24 of 30 patients with I-131-positive metastases. In 28 patients T2-201 total body scintigraphy revealed metastases which did not concentrate I-131. Histology/cytology confirmed thyroid carcinoma metastases in 16 patients and other pathology in 5 cases. 9 of 18 patients with medullary thyroid carcinoma (I-131-negative) had elevated Calcitonin/CEA-levels. The T1-201 scintigram was positive in 8 of these patients. Comparison of T1-201, I-131 and tumor markers showed that only combined use of these parameters provide complete reliability. The authors conclude that T1-201 total body scintigraphy is useful in follow up of thyroid carcinoma, especially when a discrepancy of the other parameters exists and particularly in medullary carcinoma. In long term follow up of patients who are unsuspected of disease after successful therapy for thyroid carcinoma one can rely on T1-201 total body scintigraphy in combination with tumor marker assays

  16. In-111 labeled leukocyte scintigraphy in a case of multifocal candidiasis

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, C.J.; Vega, A.; Kim, C.K.; Goldsmith, S.J. (Mount Sinai School of Medicine, New York, NY (USA))

    1990-06-01

    The value of indium-111 labeled leukocyte scintigraphy for the diagnosis of infection in the general population is well documented; there is less information available on its role in the evaluation of the immunocompromised patient. In this study, leukocyte scintigraphy was performed on a 31-year-old immunocompromised woman who had a possible intra-abdominal abscess. No abscess was detected, but intense oral, esophageal, gastric, and vaginal uptake was observed. Candida infection was histologically confirmed at all four sites.

  17. In-111 labeled leukocyte scintigraphy in a case of multifocal candidiasis

    International Nuclear Information System (INIS)

    Palestro, C.J.; Vega, A.; Kim, C.K.; Goldsmith, S.J.

    1990-01-01

    The value of indium-111 labeled leukocyte scintigraphy for the diagnosis of infection in the general population is well documented; there is less information available on its role in the evaluation of the immunocompromised patient. In this study, leukocyte scintigraphy was performed on a 31-year-old immunocompromised woman who had a possible intra-abdominal abscess. No abscess was detected, but intense oral, esophageal, gastric, and vaginal uptake was observed. Candida infection was histologically confirmed at all four sites

  18. Localization of ectopic gastric mucosa by scintigraphy

    International Nuclear Information System (INIS)

    D'Alonzo, W.A. Jr.

    1988-01-01

    When gastric mucosal tissue occurs outside of the confines of the stomach, it is termed ectopic or heterotopic. Ectopic gastric mucosa may be found within Meckel's diverticulum, duplications of the alimentary tract, and Barrett's esophagus. In addition, a surgeon may inadvertently leave behind antral gastric mucosa while performing a partial gastrectomy for peptic ulcer disease (i.e., retained gastric antrum). It is important to detect the presence and location of ectopic mucosa because acid and pepsin secretion may cause ulceration in the adjacent tissue resulting in serious complications. The only currently available specific diagnostic technique for detecting ectopic gastric mucosa is pertechnetate Tc 99m (TcO 4- ) scintigraphy. This chapter reviews the functional anatomy of gastric mucosa, the mechanism of TcO 4 - localization, the various entities containing ectopic gastric mucosa, and the methods and results of TcO 4 - scanning for these disorders

  19. SmartFABER: Recognizing fine-grained abnormal behaviors for early detection of mild cognitive impairment.

    Science.gov (United States)

    Riboni, Daniele; Bettini, Claudio; Civitarese, Gabriele; Janjua, Zaffar Haider; Helaoui, Rim

    2016-02-01

    In an ageing world population more citizens are at risk of cognitive impairment, with negative consequences on their ability of independent living, quality of life and sustainability of healthcare systems. Cognitive neuroscience researchers have identified behavioral anomalies that are significant indicators of cognitive decline. A general goal is the design of innovative methods and tools for continuously monitoring the functional abilities of the seniors at risk and reporting the behavioral anomalies to the clinicians. SmartFABER is a pervasive system targeting this objective. A non-intrusive sensor network continuously acquires data about the interaction of the senior with the home environment during daily activities. A novel hybrid statistical and knowledge-based technique is used to analyses this data and detect the behavioral anomalies, whose history is presented through a dashboard to the clinicians. Differently from related works, SmartFABER can detect abnormal behaviors at a fine-grained level. We have fully implemented the system and evaluated it using real datasets, partly generated by performing activities in a smart home laboratory, and partly acquired during several months of monitoring of the instrumented home of a senior diagnosed with MCI. Experimental results, including comparisons with other activity recognition techniques, show the effectiveness of SmartFABER in terms of recognition rates. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A parathyroid scintigraphy case study

    International Nuclear Information System (INIS)

    O'Leary, Desiree

    2005-01-01

    Background: There has been much debate concerning the most suitable protocol for parathyroid scintigraphy; the merits of various radiopharmaceuticals versus the correct imaging protocol to visualise both ectopic and anatomically placed adenomas against the various equipment choices have been debated. Aim: To demonstrate, through the use of a case study, the necessity of changing imaging protocols for parathyroid scintigraphy where a definitive imaging diagnosis is absent in the face of strong clinical suspicion. Method: Use is made of Tc99mMIBI, full field chest scintigraphy, a clearly defined imaging protocol and SPECT imaging to locate ectopic parathyroid tissue in a female patient with significant symptoms of parathyroid hyperfunction. Results: A single hyperfunctioning adenoma is located in the pre-carinal area of the mediastinum. Using a radioguided surgical technique the hyperfunctioning tissue is excised and confirmed by histopathology. Conclusion: Whilst a dramatic reduction in patient symptoms was not seen immediately in this patient, the symptoms of the illness have been subsiding since January 2003. This case study demonstrates the necessity of changing imaging protocols for parathyroid scintigraphy where a definitive imaging diagnosis is absent in the face of strong clinical suspicion

  1. Bone scintigraphy in children: trauma

    International Nuclear Information System (INIS)

    Harcke, H.T.

    1983-01-01

    The sensitivity of radionuclide imaging in identifying skeletal trauma in children has been established. Growth plates present a set of problems unique to pediatric studies and diagnotic accuracy is very technique dependent. Imaging for sports injuries and suspected child abuse has been productive. An expanding role for bone scintigraphy in the management of orthopedic problems post-trauma is developing [fr

  2. Validity of 67Ga scintigraphy in patients with oral cancer

    International Nuclear Information System (INIS)

    Kanemura, Hironari; Kondoh, Toshirou; Hamada, Yoshiki; Nakajima, Toshifumi; Sekiya, Hideki; Ito, Ko; Sato, Junichi; Seto, Kanichi

    2003-01-01

    In this study, we investigated the diagnostic usefulness of 67 Ga scintigraphy in patients with oral cancer. Fifty-five patients with previously untreated oral cancer were administered in this study. The diagnostic accuracy of 67 Ga scintigraphy for primary cancer, cervical lymph node metastasis, systemic metastasis or double cancer were studied. The relations of the size of lesions to the diagnostic accuracy, and the degree of 67 Ga-citrate accumulation were analyzed. In addition, we discussed what makes it difficult to diagnose the lesions by using 67 Ga scintigrams. As a result, the sensitivity was 44.2% in primary cancer, 28.6% in cervical lymph node metastasis, and 25.0% in systemic metastasis or double cancer. It was suggested that 67 Ga scintigraphy is disadvantageous for the detection of small lesions. In this study, the relation between the size of lesions and the degree of 67 Ga-citrate accumulation was not clarified. The diagnostic problems of 67 Ga scintigraphy were found to be its low reliability in imaging of the lesion's localization, normal biodistribution and non-specific accumulation of 67 Ga-citrate. (author)

  3. Contribution and advantages of scintigraphy in salivary pathology

    International Nuclear Information System (INIS)

    Naous, Hussein.

    1973-01-01

    Recent technical improvements, especially the use of the scintillation camera, enable kinetic studies to be carried out by isotopic exploration and salivary scintigraphy has become an easy, fast and painless method of functional investigation of the main salivary glands. This work outlines the results obtained by Tc 99m scintigraphy with a scintillation camera, relative to the most important salivary gland diseases. After an account of the anatomy and general pathology of the parotid glands and submaxillaries the chief characteristics of the tracer, the detection techniques and the method employed here are described briefly. The elementary scintigraphic aspects found in the different observations are reported, then discussed in connection with results already published. The conclusion drawn from this work is that it is possible in the vast majority of cases, by comparing and combining the morphological and kinetic study of the salivary glands by technetium 99m scintigraphy with the clinical context, to obtain very valuable information which no other complementary examination has so far been able to supply satisfactorily. Now that scintigraphy has become a method of functional and not only morphological exploration it occupies a vital place in the study of the salivary glands [fr

  4. How useful is gastroesophageal reflux scintigraphy in suspected childhood aspiration

    Energy Technology Data Exchange (ETDEWEB)

    Fawcett, H.D.; Adams, J.C.; Hayden, C.K.; Swischuk, L.E.

    1988-05-01

    It has been suggested that gastroesophageal reflux scintigraphy might be useful in assisting one in determining therapy for patients suspected of aspirating or becoming apneic secondary to gastroesophageal reflux. This, however, has not been our experience and in reviewing 23 patients with recurrent pneumonia and/or apnea who had gastroesophageal reflux scintigraphy, we were able to detect aspiration in only one. This was especially significant since 13 (59%) of these patients had demonstrable reflux, and of these, eight were treated successfully for suspected aspiration even though none was demonstrated isotopically. To be sure, the demonstration of pulmonary aspiration with gastroesophageal reflux scintigraphy had little influence on patient selection and response to therapy. For this reason we feel there is little justification in depending on the GRS for the specific purpose of trying to document pulmonary aspiration in infants and children who are refluxing. One of the more serious complications of gastroesophageal (GE) reflux is aspiration leading to recurrent pulmonary infections and/or apnea. However, it always has been difficult to demonstrate actual aspiration into the lungs, and to be sure, barium studies of the upper GI tract seldom reveal this complication. Recently, however, considerable interest has been generated in gastroesophageal scintigraphy (GRS) as a possible means of documenting such aspiration. Rationale for this stems from the fact that suspected patients can be studied over a longer period of time and in addition, delayed and overnight images can be obtained. However, our experience does not support GRS as being an adequate method for demonstrating aspiration.

  5. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  6. [Detection of auditory impairment in the offsprings caused by drug treatment of the dams].

    Science.gov (United States)

    Kameyama, T; Nabeshima, T; Itoh, J

    1982-12-01

    To study the auditory impairment induced by prenatal administration of aminoglycosides in the offspring, the shuttle box method to measure the auditory threshold of rats (Kameyama et al., Folia pharmacol. japon. 77, 15, 1981) was employed. Four groups of pregnant rats were administered 200 mg/kg kanamycin sulfate (KM), 200 mg/kg dihydrostreptomycin sulfate (DHSM), 100 mg/kg neomycin sulfate (NM), or 1 ml/kg saline intramuscularly from the 10th to the 19th day of pregnancy. The auditory threshold of the offspring could be measured by the shuttle box method in about 90% of the live born rats at the age of 100 days. The auditory thresholds of the groups were as follows (mean +/- S.E.): saline group, 53.8 +/- 0.6 dB (N = 36); KM group, 63.8 +/- 1.1 dB (N = 34); DHSM group, 60.0 +/- 1.2 dB (N = 29); NM group, 62.4 +/- 1.2 dB (N = 24). Auditory thresholds of drug-treated groups were significantly higher than that of the saline group. However, no increase in the auditory threshold of the mother rat was detected after treatment with aminoglycosides. In addition, the experimental procedure of the shuttle box method is very easy, and the auditory threshold of a large number of rats could be measured in a short period. These findings suggest that this method is a very useful one for screening for auditory impairment induced by prenatal drug treatment in rat offspring.

  7. Comparison of whole-body 18F-FDG PET, 99mTc-MIBI SPET, and post-therapeutic 131I-Na scintigraphy in the detection of metastatic thyroid cancer

    International Nuclear Information System (INIS)

    Iwata, Masahiro; Kasagi, Kanji; Misaki, Takashi; Matsumoto, Keiichi; Nakamoto, Yuji; Iida, Yasuhiro; Ishimori, Takayoshi; Higashi, Tatsuya; Saga, Tsuneo; Konishi, Junji

    2004-01-01

    The usefulness of fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) in differentiated thyroid cancer (DTC) has been demonstrated by many investigators, but in only a small number of studies have FDG-PET images been compared with those obtained using other non-iodine tumour-seeking radiopharmaceuticals. In most of the studies, planar imaging was performed for comparison using thallium-201 chloride or technetium-99m 2-methoxyisobutylisonitrile ( 99m Tc-MIBI). Furthermore, FDG-PET studies were not always performed in the hypothyroid state with increased levels of thyroid stimulating hormone (TSH), which are known to increase FDG uptake by DTC. The aim of this study was to compare the ability of FDG-PET to detect metastatic DTC with that of 99m Tc-MIBI whole-body single-photon emission tomography (SPET) and post-therapeutic iodine-131 scintigraphy, evaluated under TSH stimulation. Nineteen patients (8 men, 11 women; age range, 38-72 years, mean 60 years; 17 thyroidectomised and 2 inoperable patients following 131 I ablation of the remaining thyroid tissue; 16 papillary and 3 follicular carcinomas) with metastatic DTC underwent FDG-PET whole-body scan (WBS) and 99m Tc-MIBI SPET WBS at an interval of less than 1 week, followed by 131 I therapy. The SPET images were reconstructed using the maximum likelihood expectation maximisation (ML-EM) method. All patients were hypothyroid at the time of each scan. 131 I WBS was performed 3-5 days after oral administration of the therapeutic dose. A total of 32 lesions [10 lymph node (LN), 15 lung, 6 bone, 1 muscle] were diagnosed as metastases, as confirmed by histopathology and/or other imaging modalities (X-ray, US, CT, MRI, bone, 201 Tl and 131 I scans). FDG-PET, 99m Tc-MIBI SPET and post-therapeutic 131 I scintigraphy respectively revealed a total of 26 (81.3%), 20 (62.5%) and 22 (68.8%) lesions. These techniques respectively demonstrated nine (90.0%), eight (80.0%) and six (60.0%) LN metastases, and eleven

  8. The sensitivity and specificity of the Middlesex Elderly Assessment of Mental State (MEAMS) for detecting cognitive impairment after stroke.

    Science.gov (United States)

    Cartoni, A; Lincoln, N B

    2005-03-01

    The aim of the study was to assess the sensitivity and specificity of the MEAMS (Golding, 1989) for detecting cognitive impairment after stroke. Stroke patients admitted to hospital received a cognitive screening assessment, the MEAMS, and a detailed cognitive assessment. The information obtained from the detailed assessment was summarised in a structured written report. From the conclusions in these reports, patients were classified as "impaired" or "not impaired" in perception, memory, executive function and language. The sensitivity and specificity of the MEAMS subtests and the overall number of tests passed were determined in relation to the presence of impairment, as given in the overall conclusion of the written reports. There were 30 stroke patients, aged 58 to 92 (mean 75.80, SD 7.94) years. Of these, 17 were men and 13 were women. The sensitivity of the MEAMS subtests ranged from 11% to 100% and the specificity ranged from 69% to 100%. The sensitivity of the overall MEAMS score was 52% and the specificity was 100%, using a cut-off score of 3 or more fails to indicate impairment. Three subtests, Orientation, Naming and Unusual views had 81% sensitivity and 50% specificity for detecting problems in language, perception or memory. The MEAMS was not a sensitive screen for overall cognitive impairment or for memory, perceptual, language, or executive function problems after stroke, but it was specific. Although screening for cognitive impairment is important, the MEAMS is not recommended as the sole method, as it produces an unacceptably high false negative rate. Three subtests (Orientation, Naming and Unusual views) had 81% sensitivity and 50% specificity for detecting cognitive problems in language, perception or memory after stroke.

  9. Detecting cognitive impairment in patients with Parkinson's disease using a brief cognitive screening tool: Addenbrooke's Cognitive Examination (ACE

    Directory of Open Access Journals (Sweden)

    Anabel Chade

    Full Text Available Abstract Detecting cognitive impairment in patients with Parkinson's disease is crucial for good clinical practice given the new therapeutic possibilities available. When full neuropsychological evaluations are not available, screening tools capable of detecting cognitive difficulties become crucial. Objective: The goal of this study was to investigate whether the Spanish version of the Addenbrooke's Cognitive Examination (ACE is capable of detecting cognitive difficulties in patients with Parkinson's disease and discriminating their cognitive profile from patients with dementia. Methods: 77 early dementia patients (53 with Alzheimer's Disease and 24 with Frontotemporal Dementia, 22 patients with Parkinson's disease, and 53 healthy controls were evaluated with the ACE. Results: Parkinson's disease patients significantly differed from both healthy controls and dementia patients on ACE total score. Conclusions: This study shows that the Spanish version of the ACE is capable of detecting patients with cognitive impairment in Parkinson's disease and is able to differentiate them from patients with dementia based on their general cognitive status.

  10. Detecting cognitive impairment in patients with Parkinson's disease with a brief cognitive screening tool: the Addenbrooke's Cognitive Examination (ACE).

    Science.gov (United States)

    Chade, Anabel; Roca, María; Torralva, Teresa; Gleichgerrcht, Ezequiel; Fabbro, Nicolás; Arévalo, Gonzalo Gómez; Gershanik, Oscar; Manes, Facundo

    2008-01-01

    Detecting cognitive impairment in patients with Parkinson's disease is crucial for good clinical practice given the new therapeutic possibilities available. When full neuropsychological evaluations are not available, screening tools capable of detecting cognitive difficulties become crucial. The goal of this study was to investigate whether the Spanish version of the Addenbrooke's Cognitive Examination (ACE) is capable of detecting cognitive difficulties in patients with Parkinson's disease and discriminating their cognitive profile from patients with dementia. 77 early dementia patients (53 with Alzheimer's Disease and 24 with Frontotemporal Dementia), 22 patients with Parkinson's disease, and 53 healthy controls were evaluated with the ACE. Parkinson's disease patients significantly differed from both healthy controls and dementia patients on ACE total score. This study shows that the Spanish version of the ACE is capable of detecting patients with cognitive impairment in Parkinson's disease and is able to differentiate them from patients with dementia based on their general cognitive status.

  11. Identification of Swallowing Tasks from a Modified Barium Swallow Study That Optimize the Detection of Physiological Impairment

    Science.gov (United States)

    Hazelwood, R. Jordan; Armeson, Kent E.; Hill, Elizabeth G.; Bonilha, Heather Shaw; Martin-Harris, Bonnie

    2017-01-01

    Purpose: The purpose of this study was to identify which swallowing task(s) yielded the worst performance during a standardized modified barium swallow study (MBSS) in order to optimize the detection of swallowing impairment. Method: This secondary data analysis of adult MBSSs estimated the probability of each swallowing task yielding the derived…

  12. Heart failure and 1231-M.I.B.G. scintigraphy: comeback; Scintigraphie cardiaque a la 1231-metaiodobenzylguanidine et cardiomyopathies: le retour

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, D.; Hugentobler, A.; Costo, S.; Bouvard, G. [Centre Hospitalier Universitaire Cote de Nacre, Service de Medecine Nucleaire, 14 - Caen (France); Manrique, A. [Centre de Lutte Contre le Cancer Henri-Becquerel, Service de Medecine Nucleaire, 76 - Rouen (France); Sabatier, R.; Grollier, G. [Centre Hospitalier Universitaire Cote de Nacre, Service de Cardiologie, 14 - Caen (France); Belin, A. [Hopital de Trouville, Service de Readaptation Cardiaque, 14 - Trouville (France)

    2007-09-15

    Congestive heart failure is a often associated with an impairment of sympathetic nervous system, i.e., global hyperactivity and regional impairment of adrenergic system. Cardiac {sup 123}I-meta-iodo-benzyl-guanidine (M.I.B.G.) scintigraphy is a radionuclide technique which can explore the presynaptic adrenergic function. Cardiac fixation of M.I.B.G. is decreased in congestive heart failure, reflecting a reduction of norepinephrine uptake by the myocardial presynaptic ending nerves. The impairment of presynaptic function is early and actually involved in the pathogenesis of cardiac failure. Cardiac M.I.B.G. scintigraphy is a useful tool to explore the myocardial adrenergic stores in patients with congestive heart failure. (authors)

  13. Detection of intrathoracic infectious lesions using {sup 111}In-diethylenetriamine pentaacetic bicyclic anhydride-IgG ({sup 111}In-DTPA-IgG) scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Tomohiro; Goto, Hajime; Wada, Hiroo; Yuasa, Kazumi; Iguchi, Mari; Okamura, Tatsuru; Ieki, Ryuji; Suzuki, Kenzo [Tokyo Metropolitan Komagome General Hospital (Japan)

    1998-02-01

    The utility of {sup 111}In-DTPA-IgG imaging for the detection of intrathoracic lesions was evaluated in 10 patients with the suspicion of inflammatory or infectious diseases. They were intravenously administered 40 or 80 MBq of {sup 111}In-DTPA-IgG, and scanned after 24 or 48 hours. Of these, 8 cases, consisted of 4 cases with pneumonia and 2 cases with lung abscess and one case of pulmonary tuberculosis and one of a tuberculous pleuritis, showed true positive results. Others were one false negative case of pneumonia and one true negative case of lung cancer. Overall sensitivity and specificity were 88.9% and 100%, respectively. There were no cases which showed side effects or abnormal laboratory findings caused by the radiopharmaceuticals administered. Thus, {sup 111}In-DTPA-IgG imaging is a useful tool for the detection of intrathoracic infectious lesions. (author)

  14. Detection of intrathoracic infectious lesions using 111In-diethylenetriamine pentaacetic bicyclic anhydride-IgG (111In-DTPA-IgG) scintigraphy

    International Nuclear Information System (INIS)

    Ota, Tomohiro; Goto, Hajime; Wada, Hiroo; Yuasa, Kazumi; Iguchi, Mari; Okamura, Tatsuru; Ieki, Ryuji; Suzuki, Kenzo

    1998-01-01

    The utility of 111 In-DTPA-IgG imaging for the detection of intrathoracic lesions was evaluated in 10 patients with the suspicion of inflammatory or infectious diseases. They were intravenously administered 40 or 80 MBq of 111 In-DTPA-IgG, and scanned after 24 or 48 hours. Of these, 8 cases, consisted of 4 cases with pneumonia and 2 cases with lung abscess and one case of pulmonary tuberculosis and one of a tuberculous pleuritis, showed true positive results. Others were one false negative case of pneumonia and one true negative case of lung cancer. Overall sensitivity and specificity were 88.9% and 100%, respectively. There were no cases which showed side effects or abnormal laboratory findings caused by the radiopharmaceuticals administered. Thus, 111 In-DTPA-IgG imaging is a useful tool for the detection of intrathoracic infectious lesions. (author)

  15. Detection of occult cancer with [18F]-FDG scintigraphy in case of limbic encephalitis, a rare neurologic para neoplastic syndrome

    International Nuclear Information System (INIS)

    Kerrou, K.; Aide, N.; Montravers, F.; Grahek, D.; Younsi-Pourtau, N.; Petegnief, Y.; Colombet-Lamau, C.; Beco, V. de; Talbot, J.N.

    2003-01-01

    Limbic encephalitis is a rare neurologic para-neoplastic syndrome due to the production of anti-neuronal antibodies induced by the presence of a malignant tumour, most frequently a small cell lung cancer: The discovery and the resection of the malignant tissue allows a stabilisation of the neurological syndrome, a complete recovery being impossible when irreversible lesions are present. ( 18 F)-FDG PET may play a determinant role when the cancer is still occult after conventional imaging work-up. We report here on a such patient with evolving limbic encephalitis and no detectable cancer with conventional imaging modalities. ( 18 F)-FDG CDET successfully localised neoplastic small cell lung cancer tissue in the lung. The malignant tumour was not even detectable at surgery and was only confirmed at post surgical histology exactly exactly where it has been spotted by CDET. After surgery, the neurologic syndrome is now steady. (authors)

  16. The Value of Changing Position in the Detection of CSF Leakage in Spontaneous Intracranial Hypotension Using Tc-99m DTPA Scintigraphy: Two Case Reports.

    Science.gov (United States)

    Lu, Yu Yu; Wang, Hsin Yi; Lin, Ying; Lin, Wan Yu

    2012-09-01

    Radionuclide Cisternography (RNC) is of potential value in pointing out the sites of cerebrospinal fluid (CSF) leakage in patients with spontaneous intracranial hypotension (SIH). In the current report, we present two patients who underwent RNC for suspected CSF leakage. Both patients underwent magnetic resonance imaging (MRI) and RNC for evaluation. We describe a simple method to increase the detection ability of RNC for CSF leakage in patients with SIH.

  17. [Effectiveness of the Mini-Mental State for detection of cognitive impairment in primary care].

    Science.gov (United States)

    Carnero Pardo, Cristóbal; Cruz Orduña, Isabel; Espejo Martínez, Beatriz; Cárdenas Viedma, Salvador; Torrero García, Pedro; Olazarán Rodríguez, Javier

    2013-10-01

    To evaluate the diagnostic accuracy (DA) of the Mini-Mental State (MMS) for the detection of cognitive impairment (CI) in Primary Care (PC) and to determine the best conditions of use for that purpose. Pooled analysis of two prospective, double blind, studies on the evaluation of diagnostic tools with complete verification that were conducted in Madrid and Granada (Spain). The MMS was administered in PC and the final cognitive diagnosis (gold standard) was made in Specialized Care. Subjects with cognitive complaints or suspected of having CI were consecutively recruited in the PC clinic. The DA of the MMS was evaluated using the area under the receiver operating characteristic (ROC) curve (AUC). The best cut-off point was selected according to the ratio of cases correctly classified (RCC) and to the kappa index. Direct (MMSd) and age- and education-adjusted (MMSa) total scores were analyzed separately. In the total sample of 360 subjects (214 CI), the DA of the MMSd was significantly superior to that of the MMSa (0.84±0.02 vs 0.82±0.02, p≤.001). The yield obtained by the best cut-off point of the MMSd (22/23) was modest (RCC 0.77, kappa 0.52±0.05) and was not improved by any MMSa cut-off point. The DA of the MMS for detection of CI in PC was modest and did not improve with adjustment of the score by age and education. The best cut-off point was 22/23, inferior to the usually recommended cut-off. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  18. The development of a visual system for the detection of obstructions for visually impaired people

    International Nuclear Information System (INIS)

    Okayasu, Mitsuhiro

    2009-01-01

    In this paper, the author presents a new visual system that can aid visually impaired people in walking. The system provides object information (that is, shape and location) through the sense of touch. This visual system depends on three different components: (i) an infrared camera sensor that detects the obstruction, (ii) a control system that measures the distance between the obstruction and the sensor, and (iii) a tooling apparatus with small pins (φ1 mm) used in forming a three-dimensional shape of the obstruction. The pins, arranged on a 6x6 matrix, move longitudinally between the retracted and extended positions based on the distance data. The pin extends individually, while the pin tip reflects the object's outer surface. The length of the pin from the base surface is proportional to the distance of the sensor from the obstruction. An ultrasonic actuator, controlled at a 15Hz frame rate, is the driving force for the pin movement. The tactile image of the 3D shape can provide information about the obstruction

  19. Detection of Motor Impairment in Parkinson's Disease Via Mobile Touchscreen Typing.

    Science.gov (United States)

    Arroyo-Gallego, Teresa; Ledesma-Carbayo, Maria Jesus; Sanchez-Ferro, Alvaro; Butterworth, Ian; Mendoza, Carlos S; Matarazzo, Michele; Montero, Paloma; Lopez-Blanco, Roberto; Puertas-Martin, Veronica; Trincado, Rocio; Giancardo, Luca

    2017-09-01

    Mobile technology is opening a wide range of opportunities for transforming the standard of care for chronic disorders. Using smartphones as tools for longitudinally tracking symptoms could enable personalization of drug regimens and improve patient monitoring. Parkinson's disease (PD) is an ideal candidate for these tools. At present, evaluation of PD signs requires trained experts to quantify motor impairment in the clinic, limiting the frequency and quality of the information available for understanding the status and progression of the disease. Mobile technology can help clinical decision making by completing the information of motor status between hospital visits. This paper presents an algorithm to detect PD by analyzing the typing activity on smartphones independently of the content of the typed text. We propose a set of touchscreen typing features based on a covariance, skewness, and kurtosis analysis of the timing information of the data to capture PD motor signs. We tested these features, both independently and in a multivariate framework, in a population of 21 PD and 23 control subjects, achieving a sensitivity/specificity of 0.81/0.81 for the best performing feature and 0.73/0.84 for the best multivariate method. The results of the alternating finger-tapping, an established motor test, measured in our cohort are 0.75/0.78. This paper contributes to the development of a home-based, high-compliance, and high-frequency PD motor test by analysis of routine typing on touchscreens.

  20. Improving Sensitivity to Detect Mild Cognitive Impairment: Cognitive Load Dual-Task Gait Speed Assessment.

    Science.gov (United States)

    MacAulay, Rebecca K; Wagner, Mark T; Szeles, Dana; Milano, Nicholas J

    2017-07-01

    Longitudinal research indicates that cognitive load dual-task gait assessment is predictive of cognitive decline and thus might provide a sensitive measure to screen for mild cognitive impairment (MCI). However, research among older adults being clinically evaluated for cognitive concerns, a defining feature of MCI, is lacking. The present study investigated the effect of performing a cognitive task on normal walking speed in patients presenting to a memory clinic with cognitive complaints. Sixty-one patients with a mean age of 68 years underwent comprehensive neuropsychological testing, clinical interview, and gait speed (simple- and dual-task conditions) assessments. Thirty-four of the 61 patients met criteria for MCI. Repeated measure analyses of covariance revealed that greater age and MCI both significantly associated with slower gait speed, pscognitive dual task within a clinically representative population. Cognitive load dual-task gait assessment may provide a cost efficient and sensitive measure to detect older adults at high risk of a dementia disorder. (JINS, 2017, 23, 493-501).

  1. Clinical efficacy of 99mTc-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Adachi, Itaru; Sugioka, Yasushi; Tanaka, Yasunori

    1993-01-01

    99m Tc-tetrofosmin is a lipophilic, cationic diphosphine which has been developed for myocardial imaging. We examined 9 patients with ischemic heart disease including 3 angina pectoris (AP), 4 old myocardial infarction (OMI), 1 AP with OMI and 1 syndrome X. One patient was examined before and after operation. Three hundred seventy MBq of 99m Tc-tetrofosmin was injected during exercise and 740 MBq at rest. And 74 MBq of 201 Tl myocardial exercise and redistribution scintigraphy was also performed to compare with 99m Tc-tetrofosmin myocardial scintigraphy. SPECT, multiple gated SPECT and anterior planar images were obtained in all cases. We calculated percent wall thickening (%WT) using multiple gated SPECT images. There was a decreased lung uptake in 99m Tc-tetrofosmin planar images compared to 201 Tl myocardial scintigraphy. Liver and Biliary system uptake in 99m Tc-tetrofosmin images was decreased with intake of milk. Segmental comparison of SPECT images showed an agreement in 9/10 of the segment between 201 Tl and 99m Tc-tetrofosmin. We could obtain excellent quality of multiple gated SPECT images in all patients. We could calculate percent wall thickening (%WT) in all patients. We conclude that 99m Tc-tetrofosmin myocardial scintigraphy should provide usefulness for detection of ischemic myocardium as same as 201 Tl myocardial scintigraphy, although the biologic characteristics of two agents were different. These data and excellent quality of multiple gated SPECT images suggest that 99m Tc-tetrofosmin is a new 99m Tc agent for evaluation of patients with ischemic heart disease. (author)

  2. ROC analysis of diagnostic performance in liver scintigraphy

    International Nuclear Information System (INIS)

    Fritz, S.L.; Preston, D.F.; Gallagher, J.H.

    1981-01-01

    Studies on the accuracy of liver scintigraphy for the detection of metastases were assembled from 38 sources in the medical literature. An ROC curve was fitted to the observed values of sensitivity and specificity using an algorithm developed by Ogilvie and Creelman. This ROC curve fitted the data better than average sensitivity and specificity values in each of four subsets of the data. For the subset dealing with Tc-99m sulfur colloid scintigraphy, performed for detection of suspected metastases and containing data on 2800 scans from 17 independent series, it was not possible to reject the hypothesis that interobserver variation was entirely due to the use of different decision thresholds by the reporting clinicians. Thus the ROC curve obtained is a reasonable baseline estimate of the performance potentially achievable in today's clinical setting. Comparison of new reports with these data is impossible, but is limited by the small sample sizes in most reported series

  3. ROC analysis of diagnostic performance in liver scintigraphy.

    Science.gov (United States)

    Fritz, S L; Preston, D F; Gallagher, J H

    1981-02-01

    Studies on the accuracy of liver scintigraphy for the detection of metastases were assembled from 38 sources in the medical literature. An ROC curve was fitted to the observed values of sensitivity and specificity using an algorithm developed by Ogilvie and Creelman. This ROC curve fitted the data better than average sensitivity and specificity values in each of four subsets of the data. For the subset dealing with Tc-99m sulfur colloid scintigraphy, performed for detection of suspected metastases and containing data on 2800 scans from 17 independent series, it was not possible to reject the hypothesis that interobserver variation was entirely due to the use of different decision thresholds by the reporting clinicians. Thus the ROC curve obtained is a reasonable baseline estimate of the performance potentially achievable in today's clinical setting. Comparison of new reports with these data is possible, but is limited by the small sample sizes in most reported series.

  4. Childhood acute pyelonephritis: comparison of power Doppler sonography and Tc-DMSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Stogianni, Aggeliki; Oikonomou, Ippoliti; Dimitriadis, Athanasios [Aristotle University of Thessaloniki, Department of Radiology, AHEPA Hospital, Thessaloniki (Greece); Nikolopoulos, Panagiotis [424 Army Hospital, Department of Radiology, Thessaloniki (Greece); Gatzola, Magdalini [Aristotle University of Thessaloniki, 2nd Paediatric Clinic, AHEPA Hospital, Thessaloniki (Greece); Balaris, Vassilios [Aristotle University of Thessaloniki, Department of Nuclear Medicine, AHEPA Hospital, Thessaloniki (Greece); Farmakiotis, Dimitrios [Infectious Diseases Hospital of Thessaloniki, Department of Medicine, Thessaloniki (Greece)

    2007-07-15

    Tc 99m DMSA scintigraphy is regarded as the gold standard for the detection and localization of acute pyelonephritis (APN) in children. Power Doppler sonography (PD US) is a radiation-free and cost-effective technique that could be useful in the diagnosis of APN in children. To compare the predictive value of PD US with DMSA scintigraphy in the diagnosis of APN in children. A total of 74 neonates and children with clinical findings consistent with possible upper urinary tract infection were evaluated with PD US and DMSA scintigraphy. Children with anatomic (grey-scale) abnormalities were excluded. A total of 147 kidneys were examined within the first 48 h after the onset of symptoms. Each kidney was divided into three zones (upper, middle, and lower third). APN was diagnosed by PD US in 46 kidneys. Sensitivity and specificity for detecting APN using DMSA scintigraphy as the reference standard were 73.8% and 85.7%, respectively. There was good agreement between PD US and DMSA scintigraphy in the localization of lesions. In clinically suspected APN, PD US has acceptable specificity and sensitivity, if performed within the first 48 h and could be helpful in neonates and children under 3 months of age in whom the use of scintigraphy is generally discouraged. (orig.)

  5. Early Detection of Hearing Impairment Among High Risk Neonates in a Tertiary Care Hospital

    Directory of Open Access Journals (Sweden)

    Gurudutt Joshi

    2014-07-01

    Full Text Available Background: Hearing impairment has a devastating, detrimental and an invariably adverse impact on the development of the newborns and the psychological well-being of their families. It also adversely affects development of the central auditory nervous system, and can affect speech perception that interferes with growth in social, emotional, behavioural and cognitive spheres, academic achievement, vocational options, employment opportunities and economic selfsufficiency. Objectives: To find out incidence of hearing impairment in high risk neonates in Neonatal Intensive Care Unit (NICU, prevalence of hearing impairment with and without high risk factors in newborns and to correlate the risk factors with hearing impairment. Material and Methods: A cohort study was carried out at a tertiary care hospital of Surat, Gujarat, India consisting of 190 normal newborns and 163 newborns with high risk factors. These newborns underwent a systematized Transient Otoacoustic Emissions Examination (TOAE and Brain Stem Evoked Audiometry (BERA examination according to designed protocol and were followed up with repeated ear examinations. Data were recorded and analyzed statistically. Results: The incidence of hearing impairment in NICU, newborns were 3.6% and the prevalence of hearing impairment was 13%. Hearing impairment was statistically significant in newborns with high risk factors such as low birth weight, preterms 5 days when compared to normal newborns. Conclusion: Presence of risk factors in newborns predisposes them to hearing impairment more as compared to normal newborns and the more the number of risk factors they are exposed to, the more will be the chances of hearing impairment.

  6. Bone scintigraphy in idiopathic aseptic femoral head necrosis (IAFHN)

    Energy Technology Data Exchange (ETDEWEB)

    Dodig, D; Ugarkovic, B; Orlic, D

    1983-01-01

    Idiopathic aseptic femoral head necrosis (IAFHN) is a disease of unknown aetiology most commonly affecting adults, producing functional impairment of the hip joint and immobility. Characteristic macroscopic, microscopic and radiologic features include: (1) changes in joint cartilage, (2) subchondral necrotic area, (3) changes in fibrous tissue, and (4) osteosclerosis and vascular proliferation. The diagnosis is based on clinical and X-ray examinations. More recently scintigraphy has been used in diagnosing IAFHN. It is a very sensitive, but non-specific method. Nineteen patients aged 25-57 years were included in our study. Scintigrams were divided in four groups: (1) normal, (2) uniformly increased activity in the femoral head, (3) non-uniformly increased activity in the femoral head, and (4) a photon deficient area in the femoral head. A comparison of scintigraphy and radiological examination suggests that a photon deficient area corresponds with stage III of radiological classification, non-uniformly increased activity with stage II, and uniformly increased activity with stage I. These results indicate that scintigraphy can be used for staging of disease.

  7. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  8. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  9. Detection of recurrences of colorectal cancer using [F-18]FDG scintigraphy performed on a dual-head coincidence gamma-camera (CDET)

    International Nuclear Information System (INIS)

    Montravers, F.; Grahek, D.; Kerrou, K.; Beco, V. de; Younsi, N.; Talbot, J.N.; Beco, V. de; Tofighi, M.; Moretti, J.L.

    2001-01-01

    The aim of this study was to assess the clinical performances of FDG-CDET for the detection of recurrences of colorectal cancer. One hundred and ninety five examinations (ex) were analyzed, performed for suspicion of recurrence of colorectal cancer (148 ex) or in search of unknown foci prior to surgical resection of known recurrence(s) (47 ex). Recurrence was suspected because of rising CEA levels (50 ex) or isolated pain (8 ex) or equivocal conventional imaging (62 ex) or rising CEA levels and equivocal conventional imaging (28 ex). The results were analyzed according to histology (98 ex) or according to the one year follow-up (97 ex). On an examination basis, the results were the following: Sensitivity -143/164 = 87 %, Specificity = 28/31= 90%, Accuracy -171 /195 = 88 %. Histology was obtained in 98 patients who underwent surgery leading to the analysis of 169 sites. On a site basis, the results were the following: Sensitivity =104/152 = 68 %, Specificity =12/17 = 75 %, Accuracy -116/169 = 69 %. These results were not different from those reported with dedicated PET and show that FDG-CDET is a powerful tool for the detection of recurrent colorectal cancer. (authors)

  10. The clinical value of planar thallium-201 myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Niemeyer, M.G.

    1989-01-01

    The clinical value of planar thalium-201 myocardial perfusion scintigraphy was examined, using visual and quantitative analysis, for the detection of presence, localization and extent of coronary disease, using coronary arteriography as gold standard. The indremental diagnostic yield of different noninvasive tests for the diagnosis and the severity of coronary artery disease was quantified by using multivariate discriminant analysis. (author). 284 refs.; 14 figs.; 37 tabs

  11. Lyme myocarditis diagnosed by indium-111-antimyosin antibody scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Casans, I.; Villar, A.; Almenar, V.; Blanes, A.

    1989-06-01

    We report a new case of Lyme disease with cardiac manifestations, which has been possible to follow during the long period of 12 years. We have detected the usual ECG abnormalities, and concentric hypertrophic myocardiopathy, by echocardiography. The acute myocarditis was demonstrated by /sup 111/In-antimyosin scintigraphy, which showed global myocardial uptake of the tracer, constituting the first report, to our knowledge, of Lyme myocarditis diagnosed by this method.

  12. Lyme myocarditis diagnosed by indium-111-antimyosin antibody scintigraphy

    International Nuclear Information System (INIS)

    Casans, I.; Villar, A.; Almenar, V.; Blanes, A.

    1989-01-01

    We report a new case of Lyme disease with cardiac manifestations, which has been possible to follow during the long period of 12 years. We have detected the usual ECG abnormalities, and concentric hypertrophic myocardiopathy, by echocardiography. The acute myocarditis was demonstrated by 111 In-antimyosin scintigraphy, which showed global myocardial uptake of the tracer, constituting the first report, to our knowledge, of Lyme myocarditis diagnosed by this method. (orig.)

  13. Study of pathophysiology of pulmonary circulation in polycythemia using scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Tadashi; Kawashima, Akira; Kubo, Keiji; Kobayashi, Toshio; Handa, Kenjiro; Yoshimura, Kazuhiko (Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine)

    1993-09-01

    In order to evaluate the pathophysiology of pulmonary circulation in polycythemia, Tl-201 myocardial scintigraphy and perfusion lung scintigraphy with 99m-Tc-MAA were performed in 19 cases of polycythemia including polycythemia rubra vera and in 11 cases of secondary polycythemia due to pulmonary diseases. Tl-201 lung uptake, right ventricular visualization and pulmonary perfusion impairment were studied. In the 19 cases, Tl-201 lung uptake was observed in all cases and 54.5% of them showed moderate lung uptake. The grade of right ventricular visualization was moderate in one case and slight in 16 cases; right ventricular hypertrophy was shown in 89.5% of all cases by Tl-201 scintigraphy, only one of which showed right ventricular hypertrophy on electrocardiography. Abnormalities of lung perfusion consisted of scattered small areas of hypoperfusion in 36.8%, peripheral hypoperfusion in 78.9% and uneven distribution of pulmonary perfusion in 94.7%. The degree of hypoperfusion was slightly related to decrease in FEV 1.0%, V25 and PaO[sub 2] and increase in circulating blood volume and peripheral red blood cell counts. Abnormalities of pulmonary function consisted of increased RV/TLC in 50.0%, increased CV/VC in 35.7% and decreased V25 in 36.8%. Arterial blood gases showed hypoxemia in 57.1%, the degree of which was slightly related to increase in RV/TLC and CV/VC and decrease in V25. Cases of secondary polycythemia due to pulmonary diseases showed more marked right ventricular visualization, pulmonary perfusion impairment and abnormalities of various kinds of pulmonary function than polycythemia rubra vera cases. It seems to be important to evaluate the pathophysiology of pulmonary circulation in polycythemia rubra vera as well as secondary polycythemia due to cardio-pulmonary diseases, because pulmonary perfusion impairment and moderate right ventricular visualization are observed frequently in polycythemia rubra vera. (author).

  14. Study of pathophysiology of pulmonary circulation in polycythemia using scintigraphy

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Tadashi; Kawashima, Akira; Kubo, Keiji; Kobayashi, Toshio; Handa, Kenjiro; Yoshimura, Kazuhiko

    1993-01-01

    In order to evaluate the pathophysiology of pulmonary circulation in polycythemia, Tl-201 myocardial scintigraphy and perfusion lung scintigraphy with 99m-Tc-MAA were performed in 19 cases of polycythemia including polycythemia rubra vera and in 11 cases of secondary polycythemia due to pulmonary diseases. Tl-201 lung uptake, right ventricular visualization and pulmonary perfusion impairment were studied. In the 19 cases, Tl-201 lung uptake was observed in all cases and 54.5% of them showed moderate lung uptake. The grade of right ventricular visualization was moderate in one case and slight in 16 cases; right ventricular hypertrophy was shown in 89.5% of all cases by Tl-201 scintigraphy, only one of which showed right ventricular hypertrophy on electrocardiography. Abnormalities of lung perfusion consisted of scattered small areas of hypoperfusion in 36.8%, peripheral hypoperfusion in 78.9% and uneven distribution of pulmonary perfusion in 94.7%. The degree of hypoperfusion was slightly related to decrease in FEV 1.0%, V25 and PaO 2 and increase in circulating blood volume and peripheral red blood cell counts. Abnormalities of pulmonary function consisted of increased RV/TLC in 50.0%, increased CV/VC in 35.7% and decreased V25 in 36.8%. Arterial blood gases showed hypoxemia in 57.1%, the degree of which was slightly related to increase in RV/TLC and CV/VC and decrease in V25. Cases of secondary polycythemia due to pulmonary diseases showed more marked right ventricular visualization, pulmonary perfusion impairment and abnormalities of various kinds of pulmonary function than polycythemia rubra vera cases. It seems to be important to evaluate the pathophysiology of pulmonary circulation in polycythemia rubra vera as well as secondary polycythemia due to cardio-pulmonary diseases, because pulmonary perfusion impairment and moderate right ventricular visualization are observed frequently in polycythemia rubra vera. (author)

  15. Bone scintigraphy in drug addiction

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Majano, V.; Miskew, D.; Sansi, P.

    1981-01-01

    In 22 drug addicts, the clinical diagnosis of osteomyelitis and/or septic arthritis was suspected because of symptoms of sepsis and pain in various locations. All patients underwent bone scintigraphy with 17-20 mCi of /sup 99/sup(m)Tc labeling either pyrophosphate or methylene diphosphonate. Whole body and spot scans located the area of disease in most patients. This permitted biopsy of the affected area when the pathogen recurs. One of the two patients whose scintigrams were normal was on adequate treatment before the bone scintigram and the other was on oxacillin. Radiographs of the affected areas were normal, which indicates bone scintigraphy should be preferred to radiography in the early diagnosis of osseous infections.

  16. Bone scintigraphy in drug addiction

    International Nuclear Information System (INIS)

    Lopez-Majano, V.; Miskew, D.; Sansi, P.

    1981-01-01

    In 22 drug addicts, the clinical diagnosis of osteomyelitis and/or septic arthritis was suspected because of symptoms of sepsis and pain in various locations. All patients underwent bone scintigraphy with 17-20 mCi of 99 sup(m)Tc labeling either pyrophosphate or methylene diphosphonate. Whole body and spot scans located the area of disease in most patients. This permitted biopsy of the affected area when the pathogen recurs. One of the two patients whose scintigrams were normal was on adequate treatment before the bone scintigram and the other was on oxacillin. Radiographs of the affected areas were normal, which indicates bone scintigraphy should be preferred to radiography in the early diagnosis of osseous infections. (orig.) [de

  17. Bone scintigraphy in renal osteopathy

    International Nuclear Information System (INIS)

    Hermann, H.J.; Gahl, G.; Freie Univ. Berlin

    1976-01-01

    25 patients with chronic renal disease are investigated. In 16 cases with conservative treatment the bone scintigram showed pathological uptake according to the creatinine level, mainly in the joints of iliosacrum, hip, knee and ankles. In three patients increased uptake in the skull was found. The bone uptake found by scintigraphy was highly pronounced in the patients treated by dialysis. The most frequently involved regions were the joints of iliocacrum and hip, facial cranium, skull, pelvis and metatarsus. The count-rate ratio of cranium to chest was significantly increased in 6 patients. The investigations 6 months later showed in 4 cases a further increase compared with the first values. Count-rates of the skull were found to be comparable to the highly increased uptake in Paget's disease. Bone scintigraphy is a suitable method to estimate semiquantitatively the bone turnover in renal disease. (orig.) [de

  18. Extraosseus enrichments in bone scintigraphy

    International Nuclear Information System (INIS)

    Jochens, R.; Schumacher, T.; Amthauer, H.; Wolter, M.; Stock, W.; Stroszczynski, C.; Moersler, J.P.; Eichstaedt, H.

    1996-01-01

    Extraosseus enrichments are common findings in bone scintigraphy. Main causes are artifacts by skin or cloth contamination, paravenous and subcutaneous injection. Physical examination, removal of cloths, skin cleaning or further images in differing projections lead to the correct diagnosis artefact or extraosseous enrichments. Further on, extraosseous enrichments are seen in physiological variants. In different diseases extraosseous enrichments are common, especially in urinary tract, liver and extremities. Further diagnostics, e.g. conventional radiologic procedures, sonography and CT scans, have to be performed. In individual cases side results in bone scintigraphy lead to formerly unknown diagnosis, further diagnostic procedure is influenced decisively. Own cases show for example a cerebral apoplectic insult, formerly unknown liver metastasis or metastasis in extraosseous Ewings's sarcoma. (orig.) [de

  19. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  20. Parathyroid Scintigraphy in Renal Hyperparathyroidism

    Science.gov (United States)

    Taïeb, David; Ureña-Torres, Pablo; Zanotti-Fregonara, Paolo; Rubello, Domenico; Ferretti, Alice; Henter, Ioline; Henry, Jean-François; Schiavi, Francesca; Opocher, Giuseppe; Blickman, Johan G.; Colletti, Patrick M.; Hindié, Elif

    2015-01-01

    Secondary hyperparathyroidism (sHPT) is a major complication for patients with end-stage renal disease on long-term hemodialysis or peritoneal dialysis. When the disease is resistant to medical treatment, patients with severe sHPT are typically referred for parathyroidectomy (PTx), which usually improves biological parameters as well as clinical signs and symptoms. Unfortunately, early surgical failure with persistent disease may occur in 5%–10% of patients and recurrence reaches 20%–30% at 5 years. Presently, the use of parathyroid scintigraphy in sHPT is usually limited to the management of surgical failures after initial PTx. This review describes the strengths and limitations of typical 99mTc-sestamibi imaging protocols, and highlights the potential benefits of using parathyroid scintigraphy in the initial workup of surgical patients. PMID:23751837

  1. Bone scintigraphy in diabetic osteoarthropathy

    International Nuclear Information System (INIS)

    Eymontt, M.J.; Alavi, A.; Dalinka, M.K.; Kyle, G.C.

    1981-01-01

    Bone scans of patients with diabetic osteoarthropathy of the ankle and foot were characterized by a combination of diffuse and focal increased uptake, similar to that seen with hyperemia and reactive new bone formation. Scintigraphy showed more extensive abnormalities than radiography, with the scan abnormalities sometimes preceding the radiographic changes. The clinical and scintigraphic appearance of osteoarthropathy may improve following strict diabetic control and non-weight-bearing

  2. Liver scintigraphy of fulminant hepatitis

    International Nuclear Information System (INIS)

    Tamaki, Nagara; Ishihara, Takashi; Mori, Toru

    1980-01-01

    The liver scintigraphies of five patients with fulminant hepatitis were examined. Scintiphotos using sup(99m)Tc-phytate were taken within two weeks after the onset. Scintiphotos of 12 normal subjects, 11 cases with acute hepatitis, 17 cases with liver cirrhosis were served as control. Their scintiphotos showed reduction of the size, well-maintained uptake, mostly homogenous RI distribution, and no left lobe enlargement, which could differentiate them from the chronic liver dysfunction. In one of the cases chronological changes in liver scintigraphy were observed. The size of the liver was reduced progressively until the 16th day and re-enlarged at the 30th day and thereafter. Three indices [S/W, (R + L)/W, and L/R] were calculated. S: area of liver, R or L: longitudinal length of the right or left lobe, W: body width. Relative size of the liver expressed by S/W or (R + L)/W showed significant reduction in fulminant hepatitis compared with acute hepatitis. However, they were not different significantly from those of normal subjects. Except for liver cirrhosis, L/R (left lobe swelling index) did not show significant differences among fulminant hepatitis, normal subjects, and acute hepatitis. These indices were also useful in follow-up study of the liver scintigraphy. The liver scintigraphy in the early phase of fulminant hepatitis seems to reflect the degree of massive hepatic necrosis. It is also useful to differentiate chronic hepatic failure. Apparant reduction in scintigraphical liver size seems to suggest poor prognosis, however, it should also kept in mind that the size of the liver in this condition might change quite rapidly and greatly. (author)

  3. Thallium-201 scintigraphy in diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Corne, R.A.; Gotsman, M.S.; Weiss, A.; Enlander, D.; Samuels, L.D.; Salomon, J.A.; Warshaw, B.; Atlan, H.

    1979-01-01

    The sensitivity of rest and exercise thallium-201 scintigraphy for the detection of significant coronary artery disease and myocardial ischaemia was compared with rest and exercise electrocardiography in 46 patients with chest pain. Of 26 patients with greater that 70 per cent coronary stenosis, 16 had abnormal rest thallium-201 scintigrams and 13 had Q waves. Myocardial perfusion defects in the resting scintigram correlated very well with evidence of previous myocardial infarction (16 of 17 patients, 94%) significant Q waves were present in 13 of these 17 patients (76%). After exercise, abnormal thallium-201 scintigrams consistent with ischaemia were found in 21 patients (81%). Abnormal exercise electrocardiograms were present in 15 patients (58%). The combination of abnormal exercise thallium-201 scintigrams or exercise electrocardiograms (23/26, 88%) exceeded abnormal exercise electrocardiograms alone (15/26, 58%). The two procedures were thus complementary. Abnormal rest or exercise thallium-201 scintigrams were obtained in 25/26 patients (96%) compared with abnormal rest or exercise electrocardiograms in 21/26 patients (84%). Twenty patients with less than 50 per cent coronary stenosis had normal rest thallium-201 scintigrams and no Q waves. Two had abnormal exercise thallium-201 scintigrams and 7 had abnormal exercise electrocardiograms. Thus,exercise thallium scintigraphy has higher sensitivity than exercise electrocardiography in detecting exercise induced ischaemia and is more specific. Scintigraphy appears to have a higher sensitivity than electrocardiography in detecting coronary artery disease. (author)

  4. 123I-β-methyl-iodophenyl-pentadecanoic acid myocardial scintigraphy in diabetic patients without overt ischemic heart disease

    International Nuclear Information System (INIS)

    Shinmura, Ken; Tani, Masato; Suganuma, Yukako; Hasegawa, Hiroshi; Kawamura, Masatoshi; Nakamura, Yoshiro; Hashimoto, Jun; Kubo, Atsushi

    1995-01-01

    We evaluated 123 I-β-methyl-iodophenyl-pentadecanoic acid (BMIPP) myocardial scintigraphy in 15 diabetes mellitus patients without overt coronary heart disease. Patients with overt coronary heart disease were excluded by careful history taking, resting electrocardiography, treadmill exercise testing echocardiography and resting 201 Tl scintigraphy. Patients with remarkably impaired left ventricular (LV) systolic function (%FS 2 , FBS: 178 vs 114 mg/dl, HbA1c: 7.6 vs 6.2%, IRI: 18.5 vs 9.5 μU/ml, LVEDD: 52 vs 44 mm). 123 I-metaiodobenzyl-guanidine (MIBG) scintigraphy in the 5 patients with abnormal BMIPP uptake showed more severe defects than in the 10 patients with normal BMIPP imaging. BMIPP scintigraphy demonstrated a significant correlation between H/M and L/M by BMIPP (r=0.74). Correlation between H/M by BMIPP scintigraphy and clinical parameters (BMI, systolic blood pressure, FBS, HbA1c, IRI) were found, suggesting that diabetes mellitus patients without over coronary heart disease show abnormal BMIPP imaging when their general glucose utility and 123 I-MIBG uptake are severely impaired (progression of insulin resistance and sympathetic nerve involvement). BMIPP scintigraphy may be useful in investigating the pathogenesis and subclinical abnormality of diabetic heart. (J.P.N.)

  5. Gated blood pool scintigraphy in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Breuel, H.P.; Heusinger, J.H.; Hanisch, K.

    1984-10-01

    In 58 patients suffering from either stenosis or insufficiency of a single heart valve, gated blood pool scintigraphy was performed to determine the ejection fraction as well as the peak filling and peak ejection rates. It could be demonstrated that in patients with valvular disorders the ejection fraction was only moderately decreased, generally remaining in the lower reference range. The peak filling and ejection rates showed no pathologic changes with the exception of patients with aortic regurgitation where these rates were significantly decreased. Thus, the estimation of left ventricular peak filling and ejection rates may permit diagnosis of myocardial impairment in patients with valvular disease even under resting conditions.

  6. Isotopic scintigraphy in kidney grafting

    International Nuclear Information System (INIS)

    Renfro, Richard.

    1976-01-01

    Isotopic explorations of kidney transplants were performed on sixty-six patients. Three scintigraphic techniques were used: labelled ferrous ascorbate scintigraphy, sequential 99m technetium DTPA scintigraphy and the 131 I hippuran nephrogram. The aim of this study is to analyse the results obtained under different pathological circumstances affecting the transplant, to discuss the advantages of the techniques and to propose a working procedure. The most reliable and accurate technique is the 131 I hippuran nephrogram combined with sequential 99mTc DTPA, by which renal vascularisation may be judged labelled ferrous ascorbate on the other hand is too insensitive. Although the information supplied is mostly contained in the scintigraphic images, the nephrographic curves and the blood radioactivity decay time and rad V/rad R ratio measurements are very helpful in the early diagnosis and differential diagnosis of complications affecting the transplant. The proper use of isotopic scintigraphy in kidney grafting should provide optimum conditions for better survival of the transplant at minimum risk to the patient [fr

  7. Radiolabeled, nonspecific, polyclonal human immunoglobulin in the detection of focal inflammation by scintigraphy: Comparison with gallium-67 citrate and technetium-99m-labeled albumin

    International Nuclear Information System (INIS)

    Rubin, R.H.; Fischman, A.J.; Needleman, M.; Wilkinson, R.; Callahan, R.J.; Khaw, B.A.; Hansen, W.P.; Kramer, P.B.; Strauss, H.W.

    1989-01-01

    The accumulation of nonspecific polyclonal human immunoglobulin (IgG) radiolabeled with 125 I or 111 In was compared to that of [ 67 Ga]citrate and [ 99m Tc]albumin in rats with deep thigh inflammation due to Escherichia coli infection. Serial scintigrams were acquired at 1, 3, 24, and in some cases, 48 hr after injection. As early as 3 hr postinjection, [ 111 In]IgG showed greater accumulation at the lesion than [ 99m Tc]HSA (p less than 0.01). Both [ 125 I]IgG and [ 111 In]IgG showed greater accumulation than [ 67 Ga]citrate (p less than 0.01). At 24 hr, IgG image definition increased, while HSA image definition decreased, and the intensity of accumulation of both IgG preparations was greater than that of [ 67 Ga]citrate or [ 99m Tc]HSA (p less than 0.01). At all imaging times, [ 67 Ga]citrate accumulation was surprisingly low. In inflammation produced by Pseudomonas aeruginosa, Staphylococcus aureus, Klebsiella pneumoniae, Candida albicans, or turpentine, [ 111 In]IgG accumulation was similar to the results obtained with Escherichia coli. These studies suggest that focal sites of inflammation can be detected with radiolabeled nonspecific human polyclonal IgG

  8. Myocardial rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid scintigraphy compared with dipyridamole stress thallium-201 scintigraphy in unstable angina

    International Nuclear Information System (INIS)

    Misumi, Ikuo; Kimura, Yoshihiro; Hokamura, Youichi; Yamabe, Hiroshige; Ueno, Kazuhiro

    1998-01-01

    Twelve patients with stable angina and 12 patients with unstable angina underwent rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid (BMIPP), dipyridamole stress thallium scintigraphy and delayed thallium scintigraphy. In stable angina, sensitivity for detecting ischemic segments was higher in dipyridamole thallium (74%) than rest BMIPP (48%) images (p<0.05), but there was no significant difference between the 2 images in unstable angina. In unstable angina, the incidence of segments with higher defect scores on BMIPP images than on delayed thallium images and the opposite pattern was 27 and 5 (p<0.01). In stable angina, there was no difference. The mean defect score on BMIPP (6.3±5.6) was higher than that on delayed thallium scintigraphy (2.9±2.7) and it was almost the same as on the initial dipyridamole stress test (6.5±5.2). In conclusion, BMIPP scintigraphy is safer and may be as useful in detecting myocardial ischemia in patients with unstable angina as thallium scintigraphy. (author)

  9. Comparative study of 99Tcm-ciprofloxacin scintigraphy, 18F-FDG PET and diffusion weighted imaging for detecting secondary infection associated with severe acute pancreatitis

    International Nuclear Information System (INIS)

    Wang Jianhua; Sun Gaofeng; Zhang Jian; Shao Chengwei; Pan Guixia; Peng Ye; Mao Juanli; Zheng Jianming; Zuo Changjing

    2013-01-01

    Objective: To compare the diagnostic values of 99 Tc m -ciprofloxacin SPECT, 18 F-FDG PET and MR diffusion weighted imaging (DWI) for detecting secondary infection associated with severe acute pancreatitis (SAP) in swine. Methods: Swine models were constructed and grouped, including control group (normal swine, n=6), non-infected SAP group (inoculated with inactivation Escherichia coli, n=6)and infected SAP group (inoculated with Escherichia coli, n=16). At 7 d after inoculation,a series of 99 Tc m ciprofloxacin SPECT, 18 F-FDG PET and MR DWI scans were performed. The imaging findings were visually evaluated and semi-quantitative analyzed. Lesion-background radioactive counts ratio (L/B), SUV max and the apparent diffusion coefficient (ADC) were calculated. The image results were compared with histopathological and bacteriological results, and the sensitivity, specificity, accuracy, positive predictive value and negative predictive value were calculated. Bonferroni test, the least significant difference t test and χ 2 test were used for statistical data analysis. Results: (1) The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of 99 Tc m -ciprofloxacin SPECT via visual analysis were 93.8% (15/16), 5/6, 90.9% (20/22), 93.8%(15/16) and 5/6, whereas 81.2% (13/16), 2/6, 68.2% (15/22), 76.5%(13/17) and 2/5 for 18 F-FDG PET, and 15.4% (2/13), 5/6, 36.8%(7/19), 2/3 and 31.3% (5/16) for MRI DWI respectively. Both 99 Tc m -ciprofloxacin SPECT and 18 F-FDG PET had higher sensitivities (both P>0.05), but the specificity of 18 F-FDG PET was lower. (2) 99 Tc m -ciprofloxacin imaging showed the changes of L/B for the infected SAP swine were significantly different from those of the non-infected and normal swine (F=95.66, P<0.001). 18 F-FDG PET early-phase images showed SUV max was not significantly different between infected SAP (2.61±1.07) and non-infected SAP (1.87±0.76) groups (P>0.05), but the SUV max of infected SAP group was

  10. Using temporal orientation, category fluency, and word recall for detecting cognitive impairment: the 10-point cognitive screener (10-CS).

    Science.gov (United States)

    Apolinario, Daniel; Lichtenthaler, Daniel Gomes; Magaldi, Regina Miksian; Soares, Aline Thomaz; Busse, Alexandre Leopold; Amaral, Jose Renato das Gracas; Jacob-Filho, Wilson; Brucki, Sonia Maria Dozzi

    2016-01-01

    A screening strategy composed of three-item temporal orientation and three-word recall has been increasingly used for detecting cognitive impairment. However, the intervening task administered between presentation and recall has varied. We evaluated six brief tasks that could be useful as intervening distractors and possibly provide incremental accuracy: serial subtraction, clock drawing, category fluency, letter fluency, timed visual detection, and digits backwards. Older adults (n = 230) consecutively referred for suspected cognitive impairment underwent a comprehensive assessment for gold-standard diagnosis, of whom 56 (24%) presented cognitive impairment not dementia and 68 (30%) presented dementia. Among those with dementia, 87% presented very mild or mild stages (Clinical Dementia Rating 0.5 or 1). The incremental value of each candidate intervening task in a model already containing orientation and word recall was assessed. Category fluency (animal naming) presented the highest incremental value among the six candidate intervening tasks. Reclassification analyses revealed a net gain of 12% among cognitively impaired and 17% among normal participants. A four-point scaled score of the animal naming task was added to three-item temporal orientation and three-word recall to compose the 10-point Cognitive Screener. The education-adjusted 10-point Cognitive Screener outperformed the longer Mini-Mental State Examination for detecting both cognitive impairment (area under the curve 0.85 vs 0.77; p = 0.027) and dementia (area under the curve 0.90 vs 0.83; p = 0.015). Based on empirical data, we have developed a brief and easy-to-use screening strategy with higher accuracy and some practical advantages compared with commonly used tools. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Evaluation of DMSA scintigraphy and urography in assessing both acute and permanent renal damage in children

    Energy Technology Data Exchange (ETDEWEB)

    Stokland, E.; Jacobsson, B. [Dept. of Pediatric Radiology, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden).; Hellstroem, M. [Dept. of Radiology, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden); Jodal, U. [Dept. of Pediatrics, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden); Sixt, R. [Dept. of Pediatric Clinical Physiology, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden)

    1998-07-01

    Purpose: To evaluate dimercaptosuccinic acid (DMSA) scintigraphy and urography in the detection of renal involvement in children with urinary tract infection (UTI) in order to identify patients with a high risk of developing renal damage. Material and Methods: A total of 157 children (median age 0.4 years, range 5 days to 5.8 years) with first-time symptomatic UTI were examined scintigraphy (with an assessment of renal area involvement) and urography at the time of UTI and 1 year later. All evaluations were made blindly. Results: Of the total 314 kidneys, 80 (25%) were abnormal at initial scintigraphy. Of these 80 kidneys, 44 (55%) had normalized at follow-up. Of the 234 initially normal kidneys, 29 (12%) were abnormal at follow-up. One year after UTI, abnormalities were seen in 59 children at scintigraphy and in 18 children at urography. Renal area involvement was larger and split function abnormalities more common in kidneys that were abnormal at both scintigraphy and urography than in kidneys with only scintigraphic abnormalities. Conclusion: Quantitation of renal area involvement and split renal function at early scintigraphy would seem to be useful in identifying patients at risk of developing renal damage. Urography at 1 year after infection identified mainly those with the most severe scintigraphic abnormalities. The clinical importance of scintigraphic abnormalities that are not confirmed by urography is not known. (orig.)

  12. Evaluation of DMSA scintigraphy and urography in assessing both acute and permanent renal damage in children

    International Nuclear Information System (INIS)

    Stokland, E.; Jacobsson, B.; Jodal, U.; Sixt, R.

    1998-01-01

    Purpose: To evaluate dimercaptosuccinic acid (DMSA) scintigraphy and urography in the detection of renal involvement in children with urinary tract infection (UTI) in order to identify patients with a high risk of developing renal damage. Material and Methods: A total of 157 children (median age 0.4 years, range 5 days to 5.8 years) with first-time symptomatic UTI were examined scintigraphy (with an assessment of renal area involvement) and urography at the time of UTI and 1 year later. All evaluations were made blindly. Results: Of the total 314 kidneys, 80 (25%) were abnormal at initial scintigraphy. Of these 80 kidneys, 44 (55%) had normalized at follow-up. Of the 234 initially normal kidneys, 29 (12%) were abnormal at follow-up. One year after UTI, abnormalities were seen in 59 children at scintigraphy and in 18 children at urography. Renal area involvement was larger and split function abnormalities more common in kidneys that were abnormal at both scintigraphy and urography than in kidneys with only scintigraphic abnormalities. Conclusion: Quantitation of renal area involvement and split renal function at early scintigraphy would seem to be useful in identifying patients at risk of developing renal damage. Urography at 1 year after infection identified mainly those with the most severe scintigraphic abnormalities. The clinical importance of scintigraphic abnormalities that are not confirmed by urography is not known. (orig.)

  13. Role of scintigraphy and computer-assisted tomography in brain examination

    International Nuclear Information System (INIS)

    Akerman, M.; Oproiu, A.; Comoy, C.; Guiot, G.

    1981-01-01

    To assess the role of computer-assisted tomography (CAT) and scintigraphy in brain exploration, the authors analysed: (1) the diagnostic effectiveness of the two methods in 300 patients examined over a period of seven months; (2) the role assigned to each investigation in 169 patients operated on for intracranial lesion during the same period. The isotopic brain examination always included an initial angiographic study after the intravenous injection of a technetium compound. Study of the circulation of the cerebrospinal fluid was made with 111 In-DTPA. The detection efficiency of CAT is higher than for scintigraphy in expansive processes, whereas, conversely, in cerebrovascular accidents of ischaemic origin, isotope angiography coupled with static imaging enables one to gain more information on cerebral perfusion than CAT. Similarly, when studying the cerebrospinal fluid, scintigraphy provides a greater amount of specific data on the mechanisms governing hydrocephalus, the mode of operation of a shunt, or the site of a cerebrospinal fluid fistula. Within a neurosurgical context, CAT by and large takes precedence in brain examination, but the investigation is usually accompanied by scintigraphy or a conventional neuroradiological examination. Scintigraphy was performed on 66% of the patients, whereas for neuroradiological examination the figure was 44%. Most of the scintigraphy came after CAT so as to obtain additional diagnostic information on the vascularization, the nature and, on occasion, the exact location of the lesion revealed by CAT. In more than one case out of two, scintigraphy provides enough additional information for one to avoid neuroradiological examination, which is more 'aggressive' and more dangerous. Hence scintigraphy represents an effective complement to CAT and can compete with the conventional neuroradiological technique. (author)

  14. Impact of the scintigraphy of somatostatin receptors upon the therapeutic strategy in patients bearing digestive endocrine tumors

    International Nuclear Information System (INIS)

    Lebtahi, R.; Cadiot, G.; Genin, R.; Delahaye, N.; Faraggi, M.; Daou, D.; Peker, C.; Migon, M.; Le Guludec, D.

    1997-01-01

    The scintigraphy of somatostatin receptors (SSR) is a sensible method for detecting the gastroenteric-pancreatic endocrine tumors and their metastases. The aim of this study is to evaluate the clinical impact of the results of SSR in taking patients in therapeutic charge. A hundred and sixty patients bearing biologically and/or histologically proved digestive endocrine tumors were prospectively studied. The patients were classified in 3 groups: group I - 90 patients with no known metastases; group II - 59 patients with liver metastases and group III - 11 patients with known extra-hepatic metastases. The results of the scintigraphy were compared with those of conventional imaging. The following results were obtained: in group 1 (90 patients) the conventional imaging has allowed detecting 53 primitive tumors in 44 patients. The SSR visualized 68% of these sites and has detected 26 supplementary primitive sites in 20 patients and 29 metastatic sites in 25 patients. In group II the scintigraphy has detected 95% of hepatic metastases and revealed 23 new metastasis sites and 18/59 patients. In group III the scintigraphy has detected 11 new sites in 7 patients. The results of scintigraphy modified the patient's classification in 38 cases (24%). The therapeutic strategy was modified for 40 patients (25%). In conclusion, the scintigraphy of somatostatin receptors is able to detect a significant number of digestive endocrine tumors what has important implications for therapeutical planning of the treatment of patients. It must be carried out during pre-therapeutic extension examination of these tumors

  15. Diagnosis of pheochromocytoma using (123I)-compared with (131I)-metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Furuta, Nozomu; Kiyota, Hiroshi; Yoshigoe, Fukuo; Hasegawa, Norio; Ohishi, Yukihiko

    1999-01-01

    Patient with pheochromocytoma (PCT) cannot be cured without operation, therefore, preoperative determination of the localization of PCT should be performed accurately. ( 131 I)-Metaiodobenzylguanidine (MIBG) scintigraphy is a gold standard for the diagnosis of PCT. However, ( 123 I)-MIBG is also found to accumulate in PCT. In order to clarify the usefulness of ( 123 I)-MIBG scintigraphy for the local detection of PCT, we compared the distribution of ( 123 I)- and ( 131 I)-MIBG in patients with or without PCT. ( 131 I)- and ( 123 I)-MIBG scintigraphy was performed in 29 and 16 patients, respectively. In the former group, 14 patients had PCT, 12 had hypertension without any adrenal disorder and three had other diseases. In the latter group, eight patients had PCT, two had hypertension without any adrenal disorder and six had other diseases. The sensitivity, specificity and accuracy of ( 123 I)- with ( 131 I)-MIBG scintigraphy were compared. The sensitivity of ( 131 I)- and ( 123 I)-MIBG scintigraphy was 85.7 and 90%, respectively. The specificity of each test was 100%. The accuracy of ( 131 I)- and ( 123 I)-MIBG scintigraphy was 93.1 and 95%, respectively. The quality of images obtained using ( 123 I)-MIBG was better than with ( 131 I)-MIBG, because ( 123 I)-MIBG generated a higher dose of γ-rays with a higher specificity than ( 131 I)-MIBG. In addition, normal adrenal grands were visualized in 50% of patients tested with ( 123 I)-MIBG scintigraphy. These results indicate that ( 123 I)-MIBG scintigraphy is a valuable tool for the local detection of PCT, as is ( 131 I)-MIBG scintigraphy. Furthermore, it is possible that ( 123 I)-MIBG can be used as an alternative to ( 131 I)-MIBG for the detection of PCT. Our study was not a prospective study and the background of the patients was not matched. Further prospective studies are needed in order to determine the efficacy of ( 123 I)-MIBG scintigraphy for the diagnosis of PCT. (author)

  16. The Correction of Resolution in Scintigraphy

    International Nuclear Information System (INIS)

    Di Paola, R.; Albarede, P.; Tubiana, M.

    1969-01-01

    The informational content of activity distribution in an object becomes degraded as it passes through a scintigraphic system, and this degredation is shown in the image by distortions and by a lessening of the contrasts found in the object. The drawback can be countered by improved collimator resolution, for the collimator is the main cause of poorer modulation in the image. But as the sensitivity of collimated detectors must be sufficient to enable clinical scintigraphy to be carried out, their resolving power is limited. Recovery of the original information from an image distribution by means of response function of the detection system is a general problem that has already been examined in a number of fields. In the paper the authors have studied the problem in linear scintigraphy. The experimental nature of the study has given rise to serious problems of interpretation. The authors therefore used a UNIVAC 1107 computer for both processing and generating their images. In this way, object and image distribution before and after processing are strictly comparable. In order to compare different processing techniques (successive unfolding methods, smoothing techniques, etc.) quantitative criteria are needed, and these same quantitative criteria can be used to assess the limits of validity of the recovery operations used to be evaluated. With this aim in mind, the authors chose for their study sinusoidal sources, using as a criterion the modulation transfer function linked with a second test which can be used to assess discrepancies between distributions. The study has made it possible to select the optimum technique and to establish its exact limitations as regards information content and spatial frequency of distributions. (author) [fr

  17. Thyroidal malignancy and scintigraphy; Schilddrsenmalignitaet und Szintigrafie

    Energy Technology Data Exchange (ETDEWEB)

    Brandt-Mainz, K.; Moka, D. [Gemeinschaftspraxis fuer Radiologie und Nuklearmedizin Radionuk, Essen (Germany)

    2008-09-15

    Thyroid hypofunctional ('scintigraphic cool or cold') nodules are detected frequently. Dependent on the clinical situation, on morbidity and on economic aspects it is necessary to select patients for surgery and to avoid unnecessary surgical treatment. Therefore it is necessary to develop appropriate diagnostic algorithm to manage hypofunctional thyroid nodules. The ultrasound guided fine-needle aspiration cytology (FNA) is on the one hand side a useful diagnostic tool, but on the other hand side there exist certain limitations. It is questionable if the nodule is correctly reached. In case of heterogeneous larger mixed nodules or multiple hypofunctional nodules, it is difficult to choose the correct location of punctation. Furthermore a certain number of FNA's is not diagnostic without any result or due to 'follicular neoplasia'. {sup 99m}Tc-MIBI-sctintigraphy (MIBI) and {sup 18}F-FDG-positron-emission-tomography (FDG-PET) are established methods in the follow-up of differentiated thyroid cancer after thyroidectomy with elevated thyroglobulin-levels without adequate 131-Iodine-uptake. Moreover in case of parafollicular medullary thyroid carcinomas after thyroidectomy with elevated calcitonin-concentrations the FDG-PET is a valuable diagnostic method in localizing tumor. However these tracers gain in importance in differentiating malignant from benign preoperative hypofunctional nodules. In conclusion MIBI-scintigraphy should be used routinely to plan the correct guide of FNA. The application of both methods (MIBI and FNA) improves the differentiation of dignity, whereas a negative MIBI-examination and a negative FNA is able to exclude malignancy nearly. In this way the number of unnecessary numbers of surgical treatments can be reduced. FDG-PET is not definitely superior compared to MIBI-scintigraphy. From the cost perspective MIBI is more attractive than FDG-PET. (orig.)

  18. Clinical evaluation of the platelet scintigraphy using indium-111 oxine

    International Nuclear Information System (INIS)

    Ishikawa, Nobuyoshi; Takeda, Tohoru; Nakajima, Kohtaroh; Satoh, Motohiro; Akisada, Masayoshi; Ijima, Hiroshi

    1988-01-01

    The clinical usefulness of autologous platelets labeled with Indium-111 oxine was evaluated by scintigraphy as a diagnostic procedure for the detection of various thrombotic disorders as well as in different aneurysms. The positivity was found to be satisfactory (80.0 %) in cases of aortic aneurysm while thoracic aneurysm showed comparatively poor accumulation. High positivity was also demonstrated in deep vein thrombosis. The complimentary role of this method for intracardiac thrombi to echocardiography was noted. The labeling procedure of indium-111 oxine was fairly easy to perform and the activity of labeled platelets was sustained enough to yield good results. In one case scintigraphy was performed successfully after 19 hours of angiography when a hot area of labeled platelets was seen at the puncture site. This method was therefore varified to be a sensitive and reliable method in the assessment of thrombus activity, and as it demonstrates the activity, its helpfulness in the conservative treatment of these disorders is warranted. (author)

  19. Accuracy of abdominal lymph node scintigraphy in tumor diagnostics

    International Nuclear Information System (INIS)

    Kucharczyk, D.

    1978-01-01

    In view of the diagnostical correspondence between lymph node scintigraphy and X-ray lymphograpy, this dissertation, which is based on 110 systematic comparative evaluations, examines the diagnostical weight of the scintigraphic criteria for tumor growth, discusses diagnostical discrepancies and confirms the efficacy of lymph node scintigraphy in detecting malignomas. In discussing the diagnostical results in the light of previous experience, the shortcomings of the nuclear medical method in tumor diagnostics are shown to be attributable to the uncertainty of the individual scintigraphic criteria. Owing to the variability of the lymph node system as to topography, anatomy and retention rate and the fact that it cannot morphologically be well differentiated in the scintigram, X-ray lymphography to verify the scintigraphic result and preclude misinterpretation remains an indispensable measure. (orig.) [de

  20. Finding of region of interest in radioisotope scintigraphy's images

    International Nuclear Information System (INIS)

    Glazs, A.; Lubans, A.

    2003-01-01

    The paper is about some problems, which arise, when physicians try to make diagnosis, using information from pictures, which are obtained at radioisotope scintigraphy. The algorithm of obtaining pictures' sets (called GFR) is described in this paper. The possible mistakes in diagnosis are also described. One reason of the mistakes is wrong detection the investigated organ's location. The new method is suggested for detection of organ's location in radioisotope scintigraphy's images' sets. Using of dynamic curves of pixels' intensities is suggested for solving of this problem. It is shown, why using of maximums of such curves is impossible for finding of the investigated organ's location in radioisotope scintigraphy's images sets. The using of integral expression is suggested to solve the problem. The suggested method allows finding and selecting of investigated organ's location in image's sequences (correction is not available in the existing methods). The results of using this method are present. The method can work fully automatically or with manual setting of threshold. (authors)

  1. Arm exercise-thallium imaging testing for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Balady, G.J.; Weiner, D.A.; Rothendler, J.A.; Ryan, T.J.

    1987-01-01

    Patients with lower limb impairment are often unable to undergo a standard bicycle or treadmill test for the evaluation of coronary artery disease. To establish an alternative method of testing, 50 subjects (aged 56 +/- 10 years) performed arm ergometry testing in conjunction with myocardial thallium scintigraphy. All underwent coronary angiography; significant coronary artery disease (greater than or equal to 70% stenosis) in at least one vessel was present in 41 (82%) of the 50 patients. Thallium scintigraphy was found to have an 83% sensitivity and 78% specificity for detecting coronary disease, compared with a sensitivity and specificity of 54% (p less than 0.01) and 67% (p = NS), respectively, for exercise electrocardiography. In the subgroup of 23 patients who had no prior myocardial infarction or left bundle branch block and were not taking digitalis, thallium scintigraphy had a sensitivity of 80% versus 50% for exercise electrocardiography. Scintigraphy yielded a sensitivity of 84, 74 and 90% for one, two and three vessel disease, respectively. Noninvasive arm ergometry exercise-thallium imaging testing appears to be reliable and useful and should be considered in the evaluation of coronary artery disease in patients with lower limb impairment

  2. Sequential scintigraphy of the kidneys and joints with 99mTc-pyrophosphate in patients with rheumatic arthritis

    International Nuclear Information System (INIS)

    Askerov, N.M.; Dzhafarov, G.A.

    1990-01-01

    The proposed method of sequential scintigraphy of the kidneys and joints in a single administration of 99m Tc-pyrophosphate permits obtaining objective information on function and topography of the kidneys and pyodestructive processes in the joints. Dynamic scintigraphy helps to assess visually renal hemodynamics and the anatomotopographic position of the kidney and to obtain exhaustive information on accumulative-evacuatory function of each kidney individually. Scintigraphy also helps to investigate all the joints and to detect pyoinflammatory changes in them. The proposed method considerably reduces the time of investigation and lessens radiation exposure of patients, permitting repeated investigations to assess and correct the treatment of patients with rheumatic arthritis

  3. Two-dimensional fusion imaging of planar bone scintigraphy and radiographs in patients with clinical scaphoid fracture: an imaging study

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Lonsdale, Markus Georg; Jensen, T D

    2009-01-01

    . Bone scintigraphy is highly sensitive for the detection of fractures, but exact localization of scintigraphic lesions may be difficult and can negatively affect diagnostic accuracy. PURPOSE: To investigate the influence of image fusion of planar bone scintigraphy and radiographs on image interpretation......BACKGROUND: Although magnetic resonance imaging (MRI) is now considered the gold standard in second-line imaging of patients with suspected scaphoid fracture and negative radiographs, bone scintigraphy can be used in patients with pacemakers, metallic implants, or other contraindications to MRI....... CONCLUSION: Image fusion of planar bone scintigrams and radiographs has a significant influence on image interpretation and increases both diagnostic confidence and interobserver agreement....

  4. Gastrointestinal scintigraphy in children

    International Nuclear Information System (INIS)

    Mann, M.D.

    2004-01-01

    Full text: Milk scans are by far the commonest GI study we perform. All babies regurgitate to a greater or lesser extent and there is no clear distinction between normal and abnormal. In addition gastro-oesophageal reflux (GOR) is not the only cause of regurgitation; regurgitation may be due to abnormal oesophageal transit, GOR or slow gastric emptying. The milk scan can detect and quantify these abnormalities. It may also detect pulmonary aspiration if this occurs during the study period. Short bowel syndrome, soiling and a constipation are the commonest indications for small and large bowel transit studies. Children with feeding difficulties and short bowel syndrome often have a segment at which hold up occurs while most children with soiling have normal or even rapid transit through small and large bowel. Ingestion of caustic substances by young children is a frequent cause of presentation at paediatric emergency centers and about 20% of these patients have significant oesophageal injury requiring ongoing therapy to prevent stricture formation. A 99m Tc sucralfate swallow is an accurate method for assessing the oesophageal injury and may be used to document healing. The methods for labeling sucralfate and performing the scan are simple. Meckel's scans are useful but require careful preparation of the patient and attention to detail. GI bleeding studies with colloid or labeled red blood cells are often requested but I find accurate localization of the bleeding site extremely difficult. (author)

  5. Detection of impaired fatty acid metabolism in right ventricular hypertrophy. Assessment by I-123 {beta}-methyl iodophenyl pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-ih; Goto, Hideki; Kobayashi, Katsuhiro; Sawada, Yoshihiro; Miyake, Yoshitaka; Fujiwara, Go [Nishiyodo Hospital, Osaka (Japan); Chiba, Hiroshi; Okada, Tomoya; Nishimura, Tsunehiko

    1997-08-01

    The subjects consisted of 6 patients with chronic obstructive pulmonary disease, 4 with primary pulmonary hypertension, 2 each with refractory pulmonary tuberculosis, tricuspid insufficiency, pulmonary embolism, 1 each with atrial septal defect, ventricular septal defect (Eisenmenger complex), Ebstein anomaly, and endocardial defect, and 7 healthy controls. SPECT imaging with Tl-201 (Tl) and I-123 BMIPP, and Tc-99m RBC first pass and gated blood pool scintigraphy were performed. Based on Tl planar images, the subjects were classified into 3 groups: 7 patients with no RV visualization (Group A), 11 with moderate RV visualization (Group B) and 9 with marked RV visualization (Group C). As a semi-quantitative evaluation by a myocardial SPECT, 3 regions in 3 representative short axial images were divided into 9 segments, each of which was graded from 0 to +3, and their sum was calculated as the RV score. The right ventricular ejection fraction (RVEF) and the left ventricular ejection fraction were obtained by Tc-99m RBC cardiac scintigraphy. The groups with marked visualization of the right ventricle had lower RVEF, and there was a good correlation between the RVEF and the RV score with both a and BMIPP. Although a good correlation was demonstrated between the RV score with Tl and BMIPP in Groups A and B, in Group C, in which there was marked RV Tl visualization, the RV score with BMIPP was significantly smaller than with Tl. These findings suggest that impaired fatty acid metabolism may exist in severely hypertrophic right ventricle due to RV overload. (K.H.)

  6. Detection of impaired fatty acid metabolism in right ventricular hypertrophy. Assessment by I-123 β-methyl iodophenyl pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kim, Yong-ih; Goto, Hideki; Kobayashi, Katsuhiro; Sawada, Yoshihiro; Miyake, Yoshitaka; Fujiwara, Go; Chiba, Hiroshi; Okada, Tomoya; Nishimura, Tsunehiko.

    1997-01-01

    The subjects consisted of 6 patients with chronic obstructive pulmonary disease, 4 with primary pulmonary hypertension, 2 each with refractory pulmonary tuberculosis, tricuspid insufficiency, pulmonary embolism, 1 each with atrial septal defect, ventricular septal defect (Eisenmenger complex), Ebstein anomaly, and endocardial defect, and 7 healthy controls. SPECT imaging with Tl-201 (Tl) and I-123 BMIPP, and Tc-99m RBC first pass and gated blood pool scintigraphy were performed. Based on Tl planar images, the subjects were classified into 3 groups: 7 patients with no RV visualization (Group A), 11 with moderate RV visualization (Group B) and 9 with marked RV visualization (Group C). As a semi-quantitative evaluation by a myocardial SPECT, 3 regions in 3 representative short axial images were divided into 9 segments, each of which was graded from 0 to +3, and their sum was calculated as the RV score. The right ventricular ejection fraction (RVEF and the left ventricular ejection fraction were obtained by Tc-99m RBC cardiac scintigraphy. The groups with marked visualization of the right ventricle had lower RVEF, and there was a good correlation between the RVEF and the RV score with both a and BMIPP. Although a good correlation was demonstrated between the RV score with Tl and BMIPP in Groups A and B, in Group C, in which there was marked RV Tl visualization, the RV score with BMIPP was significantly smaller than with Tl. These findings suggest that impaired fatty acid metabolism may exist in severely hypertrophic right ventricle due to RV overload. (K.H.)

  7. Scintigraphy of the pancreas head

    Energy Technology Data Exchange (ETDEWEB)

    Basse-Cathalinat, B; Beck, C; Ducassou, D; Blanquet, P [Hopital Pellegrin, 33 - Bordeaux (France)

    1975-01-01

    Emphasis is placed on the considerable improvement due to the computer in pancreatic scintigraphy, which has become more exact as a result. A liver subtraction technique is used. From the data acquired in this method two matrices are established, one for selenomethionine 75 and the other for gold 198. For processing the data are integrated in two broad hepatic areas, of coordinates identical in the two scintigrams, and their ratio is found; the computer multiplies the specifically hepatic matrix by this ratio then subtracts one from the two scintigrams thus normalized. The background can be subtracted from the resulting image.

  8. Usefulness of gastroesophageal reflux scintigraphy using the knee-chest position for the diagnosis of gastroesophageal reflux disease

    International Nuclear Information System (INIS)

    Asakura, Yasushi; Imai, Yukinori; Ota, Shinichi; Fujiwara, Kenji; Miyamae, Tatsuya

    2005-01-01

    The aim of this study is to evaluate the usefulness of gastroesophageal reflux (GER) scintigraphy using the knee-chest (KC) position for the diagnosis of gastroesophageal reflux disease (GERD). The study subjects were 37 patients with GERD and 8 healthy volunteers (control group). Endoscopically observed esophageal mucosal breaks were evaluated with the Los Angeles classification. For GER scintigraphy, the subjects ingested liquid yogurt labeled with 99m Tc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) and water. Imaging was performed in the supine and KC position, and GER was graded as 1-4 according to the extent of GER assessed by scintigraphy. GER scintigraphy revealed no reflux in the control group (specificity: 100%). In the supine position, gastroesophageal reflux was observed in 49% of the patients with GERD, compared to 76% in the KC position. 21 of 23 (91%) patients with erosive esophagitis were shown to have GER with scintigraphy. GER scintigraphy revealed severe reflux (grade 3 or 4) (83%, 10/12) in the patients who had severe mucosal breaks (the Los Angels classification grade C or D). GER scintigraphy detected grade 1 or 2 reflux in 7 of the 14 patients who were endoscopically negative. There was a correlation between the endoscopically determined severity of mucosa and the reflux grade which was determined with GER scintigraphy. GER scintigraphy can detect gastroesophageal reflux with a high sensitivity in the KC position and might be a useful method in the screening and assessment of the severity of this disease. This method would be useful for the diagnosis of GERD in endoscopically negative patients. (author)

  9. Comparison of indium-111 platelet scintigraphy and two-dimensional echocardiography in the diagnosis of left ventricular thrombi

    International Nuclear Information System (INIS)

    Ezekowitz, M.D.; Wilson, D.A.; Smith, E.O.; Burow, R.D.; Harrison, L.H. Jr.; Parker, D.E.; Elkins, R.C.; Peyton, M.; Taylor, F.B.

    1982-01-01

    In a study comparing indium-111 platelet scintigraphy and two-dimensional echocardiography as methods of identifying left ventricular thrombi, the results obtained with both techniques were verified at surgery or autopsy in 53 patients-34 with left ventricular aneurysms, and 19 with mitral-valve disease. Left ventricular thrombi were found at surgery or autopsy in 14 of the patients with aneurysms and in none of those with mitral-valve disease. Thirteen of 53 echocardiograms (25%) were technically inadequate and excluded from the analysis. In the group with aneurysms, the sensitivity of scintigraphy in detecting thrombi was 71%, and that of echocardiography was 77%. The specificity of scintigraphy was 100%, and that of echocardiography was 93%. We conclude that indium-111 platelet scintigraphy and two-dimensional echocardiography have useful and complementary roles in the detection of left ventricular thrombi. Both these noninvasive techniques can be used to monitor therapy

  10. Value of gallium 67 citrate scintigraphy in ophthalmology

    International Nuclear Information System (INIS)

    Ivanez-Alloschery, Monique.

    1978-01-01

    For ophthalmologists scintigraphy appears as a simple method to detect endoocular or endoorbital abnormalities. However none of the many scintigraphic methods described seems reliable enough to be used alone. One of the latest isotopic explorations using gallium 67 citrate, a tracer considered tumour-tropic might be able to solve this problem. The aim of this work is to judge the value of the method in the diagnosis of malignant endoocular and endoorbital tumours on the basis of 24 anatomoclinical observations. It may be concluded from this study that ocular gallium 67 citrate scintigraphy, which gave no clearly positive results at all but some doubtful results in the case of endoocular tumours more than 5 mm in diameter, is to be rejected; fluorescein angiography and ocular echograhy provide more elements for an accurate etiological diagnosis. Orbital scintigraphy on the other hand seems to be a necessary complement to a tomodensitometric examination since both methods offer diagnostic information without systematic recurse to carotid arteriography or orbital phlebography, sometimes dangerous for the patient [fr

  11. Somatostatin receptor scintigraphy in patients with cat-scratch disease

    International Nuclear Information System (INIS)

    Krause, R.; Schnedl, W.J.; Hoier, S.; Piswanger-Soelkner, C.; Lipp, R.W.; Daxboeck, F.; Reisinger, E.C.

    2006-01-01

    Aim: somatostatin receptor scintigraphy images various neoplastic, granulomatous, and auto-immun diseases. Cat-scratch disease in an infectious granulomatous disease usually affecting the lymphnodes. It is not known whether cat-scratch disease provides positive somatostatin receptor scintigrams. Patients, methods: twelve patients with lymphadenitis and suspected cat-scratch disease were investigated by immunofluorescence antibody testing and somatostatin receptor scintigraphy. Suppurated lymphnodes were extracted or drained and Bartonella henselae specific PCR was then performed. Results: eleven of 12 patients showed IgG antibodies against B. henselea. SRS showed positive scintigraphic results in 6 of 11 patients with CSD. B. henselae DNA was detected in tissue of lymphnodes from 4 of 5 patients with lymphnode extraction or lymphnode drainage. SRS demonstrated positive scintigrams in all patients with a positive PCR. In one patient with suspected CSD SRS was negative as well as antibody testing. Conclusion: somatostatin receptor scintigraphy correlated with positive Bartonella henselae specific PCR tests and positive Bartonella henselae specific antibody tests in patients with CSD. (orig.)

  12. Perfusion lung scintigraphy in primary broncho-pulmonary cancer

    International Nuclear Information System (INIS)

    Lapergue, Paul.

    1976-01-01

    Research on primary broncho-pulmonary cancer has called extensively on scintigraphy and it seemed interesting to weigh up the pros and cons of the technique in this particular case. Our intention is to sum up objectively from recent documents the applications of scintigraphy in the study of primary broncho-pulmonary cancers and to attempt, on the basis of the results compiled, to show what benefits have been gained from this technique and to find out whether it has any pre-surgical value and of what kind. The technique was invariable; the tracer consists of human albumin macro-aggregates labelled with technetium 99m which by its short half-life and slight penetration enables four exposures to be taken during the same examination (front, back, right and left profiles), thus reducing the risks of mistaken diagnoses due to the use of a single incidence. Similarly the detection method was always the scintillation camera which explores the whole organ at once, considerably shortening the examination time. Lung scintigraphy by perfusion of labelled human albumin macro-aggregates offers the great advantage of being simple to use and harmless. It is easy to understand the important place it has taken in the range of methods available for lung circulation exploration [fr

  13. /sup 131/I-meta-iodobenzylguanidine scintigraphy of neuroblastomas

    International Nuclear Information System (INIS)

    Munkner, T.

    1986-01-01

    Sixteen neuroblastoma patients have been studied by /sup 131/I-meta-iodobenzylguanidine scintigraphy. Three patients were possibly cured, and their scintigraphy results were normal. Thirteen patients had tumors and metastases demonstrated by /sup 131/I-MIBG, two of these patients had a normal vanillylmandelic acid excretion levels. One patient has been treated by /sup 131/I-MIBG, but died. /sup 131/I-MIBG was concentrated in other cells too, e.g., in erythrocytes and platelets. Neuroblastoma is the most common solid malignant disease in children. It has a poor prognosis in patients more than one year old. Early detection and a display of the spread of the tumor is of utmost importance for planning and controlling the treatment. Mass screening for neuroblastoma in infants has been suggested and tried in Japan. Scintigraphy after injection of /sup 131/I-meta-iodobenzylguanidine has been used successfully for locating neuroblastomas. An initial study failed to demonstrate neuroblastoma by means of MIBG in two patients. Since the latter part of 1983, MIBG has been used in a number of European centers for imaging neuroblastomas with very promising results, and a multicenter investigation has been initiated. The Ann Arbor group has recently extended its studies to a group of ten patients and has confirmed the European results

  14. Contribution of scintigraphy in the search for bone metastases

    International Nuclear Information System (INIS)

    Miossec, Andre.

    1976-01-01

    The inclusion of scintigraphy in the repertory of diagnostic techniques is quite recent, but this examination is continually gaining in importance. In the case of bone metastases it certainly contributes to early diagnosis, a factor which is still the foremost condition of therapeutic efficiency. However some faults persist in the detection of metastases and it is hoped that the isotopic technique will gradually eliminate these errors. Scintigraphy in fact is still in its infancy, and several products are used for want of a consensus. Many improvements are expected in the future, whether in the technique itself or in its reliability or interpretation. - Technical improvement with the appearance of more sensitive instruments, tomography... - Improved interpretation by the acquisition of images on which hypofixation and hyperfixation zones will be more clearly differentiated and by a more accurate, more mathematical estimation of hypofixation and hyperfixation. Progress is already very rapid in this respect owing to the arrival of computerization. - Better reliability, perhaps the field in which hopes are highest: discovery of new radioactive products acting selectively in the metabolism or catabolism of the neoplasic process. Scintigraphy is a technique undoubtedly destined for considerable further development and called on to play an increasingly important part in cancer diagnosis and even in research on the cancer call development process itself [fr

  15. Somatostatin receptor scintigraphy in patients with cat-scratch disease

    Energy Technology Data Exchange (ETDEWEB)

    Krause, R.; Schnedl, W.J.; Hoier, S. [Div. of Infectious Diseases, Dept. of Internal Medicine, Univ. Graz (Austria); Piswanger-Soelkner, C.; Lipp, R.W. [Div. of Nuclear Medicine, Dept. of Internal Medicine, Univ. Graz (Austria); Daxboeck, F. [Clinical Inst. for Hygiene and Medical Microbiology, Div. of Hospital Hygiene, Univ. of Vienna (Austria); Reisinger, E.C. [Div. of Infectious Diseases and Tropical Medicine, Dept. of Internal Medicine, Univ. Rostock (Germany)

    2006-07-01

    Aim: somatostatin receptor scintigraphy images various neoplastic, granulomatous, and auto-immun diseases. Cat-scratch disease in an infectious granulomatous disease usually affecting the lymphnodes. It is not known whether cat-scratch disease provides positive somatostatin receptor scintigrams. Patients, methods: twelve patients with lymphadenitis and suspected cat-scratch disease were investigated by immunofluorescence antibody testing and somatostatin receptor scintigraphy. Suppurated lymphnodes were extracted or drained and Bartonella henselae specific PCR was then performed. Results: eleven of 12 patients showed IgG antibodies against B. henselea. SRS showed positive scintigraphic results in 6 of 11 patients with CSD. B. henselae DNA was detected in tissue of lymphnodes from 4 of 5 patients with lymphnode extraction or lymphnode drainage. SRS demonstrated positive scintigrams in all patients with a positive PCR. In one patient with suspected CSD SRS was negative as well as antibody testing. Conclusion: somatostatin receptor scintigraphy correlated with positive Bartonella henselae specific PCR tests and positive Bartonella henselae specific antibody tests in patients with CSD. (orig.)

  16. Gallium scintigraphy in AIDS

    International Nuclear Information System (INIS)

    Van der Wall, Hans; Provan, I.; Murray, C.; Dwyer, M.; Jones, P.D.

    1990-01-01

    Gallium-67 scanning, indicated either for the elucidation of symptoms or for the assessment of appropriate therapy, was performed in 56 AIDS patients who underwent a total of 77 scans from 1986 to 1988. The age range of the patients was 13-66 years with an average age of 39 years. The majority of patients (95%) were male homosexuals. Gallium scanning has been applied to a wide spectrum of malignancies and to the detection of occult infections. Several mechanisms of uptake have been postulated for the localization of gallium. In general, gallium-67 acts as an analogue of the ferric ion, binding to transferrin soon after intravenous injection. It is believed that it is bound to transferrin receptors on the surface of tumour cells with subsequent intracellular transport. In infection, the association is probably with lactoferrin elaborated by polymorphonuclear cells and siderophores elaborated by bacteria. Gallium-67 is normally distributed to bone and bone marrow, liver, spleen, breast and bowel. In particular, the concentration in the ascending and transverse colon necessitates adequate bowel preparation. Lacrimal, nasopharyngeal and genital activity may also be seen. 11 refs., 2 tabs., 6 figs

  17. Memory and Executive Screening for the Detection of Cognitive Impairment in Obstructive Sleep Apnea.

    Science.gov (United States)

    Mu, Li; Peng, Liping; Zhang, Zhengjiao; Jie, Jing; Jia, Siqi; Yuan, Haibo

    2017-10-01

    Obstructive sleep apnea (OSA) is commonly associated with cognitive dysfunction, which is more apparent in severe OSA and impairs quality of life. However, the clinical screening methods for these impairments in OSA are still limited. In this study, we evaluated the feasibility of using the Memory and Executive Screening (MES) for assessing cognitive performance in OSA. Twenty-four patients with nonsevere OSA and 36 patients with severe OSA participated in this study. All participants underwent comprehensive, laboratory-based polysomnography and completed assessments of cognitive function, which included both the MES and the Beijing version of the Montreal Cognitive Assessment (MoCA-BJ). Both the total MES scores and 5 recall scores of the MES (MES-5R) were significantly lower in the severe OSA group than those in the nonsevere OSA group. The patients with severe OSA performed worse on the memory subtests of the MES-5R, especially on immediate recall. The sensitivity and specificity of the MES for identifying cognitive impairment in patients with OSA were 63.89% and 66.67%, respectively, for a cutoff value of cognitive dysfunction in patients with OSA. The sensitivity and specificity of the MES were similar to those of the MoCA-BJ. The MES-5R and total MES scores can assess the presence and severity of cognitive impairment in patients with severe OSA. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  18. Early Detection of Cognitive-Linguistic Change Associated with Mild Cognitive Impairment

    Science.gov (United States)

    Fleming, Valarie B.

    2014-01-01

    Individuals with mild cognitive impairment (MCI) may present with subtle declines in linguistic ability that go undetected by tasks not challenging enough to tax a relatively intact cognitive-linguistic system. This study was designed to replicate and extend a previous study of cognitive-linguistic ability in MCI using a complex discourse…

  19. How useful is gastroesophageal reflux scintigraphy in suspected childhood aspiration?

    International Nuclear Information System (INIS)

    Fawcett, H.D.; Adams, J.C.; Hayden, C.K.; Swischuk, L.E.

    1988-01-01

    It has been suggested that gastroesophageal reflux scintigraphy might be useful in assisting one in determining therapy for patients suspected of aspirating or becoming apneic secondary to gastroesophageal reflux. This, however, has not been our experience and in reviewing 23 patients with recurrent pneumonia and/or apnea who had gastroesophageal reflux scintigraphy, we were able to detect aspiration in only one. This was especially significant since 13 (59%) of these patients had demonstrable reflux, and of these, eight were treated successfully for suspected aspiration even though none was demonstrated isotopically. To be sure, the demonstration of pulmonary aspiration with gastroesophageal reflux scintigraphy had little influence on patient selection and response to therapy. For this reason we feel there is little justification in depending on the GRS for the specific purpose of trying to document pulmonary aspiration in infants and children who are refluxing. One of the more serious complications of gastroesophageal (GE) reflux is aspiration leading to recurrent pulmonary infections and/or apnea. However, it always has been difficult to demonstrate actual aspiration into the lungs, and to be sure, barium studies of the upper GI tract seldom reveal this complication. Recently, however, considerable interest has been generated in gastroesophageal scintigraphy (GRS) as a possible means of documenting such aspiration. Rationale for this stems from the fact that suspected patients can be studied over a longer period of time and in addition, delayed and overnight images can be obtained. However, our experience does not support GRS as being an adequate method for demonstrating aspiration. (orig.)

  20. The value of RI scintigraphy and angiography in small intestinal bleeding; Report of eight cases

    Energy Technology Data Exchange (ETDEWEB)

    Kurosawa, Susumu; Kuwata, Hajime; Kushibiki, Kyoko; Akimoto, Kimihiko; Hashimoto, Toshiyuki; Kojima, Toshiya (Showa General Hospital, Kodaira, Tokyo (Japan))

    1991-07-01

    We retrospectively reviewed eight cases of small intestinal bleeding and assessed the value of RI scintigraphy and angiography in diagnosing the bleeding site. The patients' average age was 56.2 years. Chief complaint was melena of variable degree. In most cases neither upper endoscopy nor colonoscopy was diagnostic. RI scientigraphy (Tc-99 labeled human serum albumin) showed 75% of positive rate whereas angiography showed 66.7% (4/6) of positive rate. All four cases of leiomyosarcoma and leiomyoma demonstrated hypervascular stain and/or extra-vasation in angiography whereas RI scintigraphy failed to detect active gastrointestinal bleeding in 2 of the 4 cases. Therefore angiography was considered useful for the detection of bleeding from leiomyoma and leiomyosarcoma which are often hypervascular. Scintigraphy is thought of most value in the demonstration of small amount of bleeding with minimum vascular abnormality. (author).

  1. Thallium scintigraphy during dobutamine infusion: nonexercise-dependent screening test for coronary disease

    International Nuclear Information System (INIS)

    Mason, J.R.; Palac, R.T.; Freeman, M.L.; Virupannavar, S.; Loeb, H.S.; Kaplan, E.; Gunnar, R.M.

    1984-01-01

    Exercise thallium scintigraphy has proven to be a sensitive method for detecting coronary artery disease (CAD). However, early redistribution of thallium and inadequate exercise can reduce its sensitivity. In this study, dobutamine was infused in incremental doses (5, 10, 15, and 20 micrograms/kg/min) in 24 patients being evaluated for chest pain. Thallium scintigraphy was completed during the maximum dose of dobutamine tolerated and repeated 4 hours later. Significant CAD was present in 16 patients; the remaining eight had normal coronaries. Exercise ECG was obtained in 23 patients. During dobutamine thallium scintigraphy, reversible perfusion defects occurred in 15 of 16 CAD and in one of eight non-CAD patients, resulting in a sensitivity of 94% and a specificity of 87%. Exercise ECG had a sensitivity of 60% and a specificity of 63%. We conclude that: (1) dobutamine thallium scintigraphy appears to be a sensitive method for detecting significant CAD and provided a more sensitive screening test than exercise ECG; (2) dobutamine thallium scintigraphy is especially useful in patients who cannot exercise; and (3) because imaging occurs during dobutamine infusion, the problem of early redistribution may be mitigated

  2. Comparison of dipyridamole-echocardiography with dipyridamole-thallium scintigraphy for the diagnosis of myocardial ischemia

    International Nuclear Information System (INIS)

    Perin, E.C.; Moore, W.; Blume, M.; Hernandez, G.; Dhekne, R.; DeCastro, C.M.

    1991-01-01

    After an intravenous infusion of dipyridamole (0.56 mg/kg), the authors performed both echocardiography and thallium scintigraphy in 63 patients who were referred for known or suspected coronary artery disease. Of those patients, 25 returned for coronary arteriography within 1 month after the tests, thus forming the study group for this report. Sensitivity for detection of coronary artery disease, when analyzed region-by-region, was 80% for thallium scintigraphy and 57% for echocardiography, whereas specificity was 85% and 98%, respectively. When evaluating individual patients for the presence or absence of ischemia, they found a sensitivity of 95% for scintigraphy and 58% for echocardiography; corresponding specificities were 50% and 100%. By using arteriography as the gold standard for comparison, it appears that thallium scintigraphy has a significantly higher sensitivity but lower specificity for the detection of coronary artery disease than does echocardiography. Echocardiography may, however, be a useful adjunct to thallium scintigraphy in the evaluation of patients with coronary artery disease

  3. The impaired driver: hospital and police detection of alcohol and other drugs of abuse in motor vehicle crashes.

    Science.gov (United States)

    Orsay, E M; Doan-Wiggins, L; Lewis, R; Lucke, R; RamaKrishnan, V

    1994-07-01

    To determine the incidence of drugs of abuse and alcohol use in admitted drivers involved in motor vehicle crashes (MVCs) and to determine the rate of police detection of alcohol and drug use in these motorists. Retrospective chart review of hospitalized drivers involved in MVCs and review of corresponding police reports. Two Level I trauma centers in a large metropolitan region. All MVC drivers/motorcycle operators admitted to the trauma service from January 1, 1990, to December 31, 1990. The records of 634 injured motorists were reviewed; 200 (32% of the 625 patients with serum alcohol levels) were legally drunk (serum alcohol of 100 mg/dL or more), and 132 (22.6% of the 585 urine drug screens) had positive urine drug screens. Cocaine was the most prevalent drug of abuse, present in 51 patients (8.7%). Two hundred eighty-five patients (45.0%) were considered impaired (alcohol of 100 mg/dL or more and/or positive drug screen), representing almost half of all motorists admitted. The impaired motorists were younger, more often male, less likely to use a seat belt or helmet, and had higher Injury Severity Scores than their unimpaired counterparts. Police reports were available for 446 patients, 139 (31.2%) of whom were legally drunk and 67 (15%) of whom had positive drug screens, yielding an overall impairment rate of 46.2%. Only 34 (16.5%) patients were cited for driving under the influence. An exceedingly high rate of impairment existed in this population of seriously injured motorists in a metropolitan region, the majority of whom were not charged by the police. Although alcohol is the most prevalent source of driver impairment, other drugs of abuse are also important contributors to this problem.

  4. Usefulness of pulmonary scintigraphy in primary lung cancer patients treated by radiotherapy

    International Nuclear Information System (INIS)

    Mitomo, Osamu

    1994-01-01

    To assess the pulmonary function of lung cancer patients treated by radiotherapy, we tried qualitative and semiquantitative analysis of pulmonary scintigrams using 133 Xe and 99m Tc-MAA. Individual scores for ventilation, perfusion and the ventilation-perfusion ratio of tumor-bearing lungs were calculated on the basis of healthy control cases in order to analyze whether, and to what degree, the tumor-bearing lung was functionally impaired. The score was proportional to the severity of impairment, and when the ventilation and perfusion of tumor-bearing lungs had a score of one or greater than one, the tumor-bearing lung was functionally defined as an 'impaired lung'. Impaired lungs were demonstrated in 68% of tumor-bearing lungs. Hilar and left hilar-type cancers, clinically more advanced cancers, patients whose tumors were confirmed by bronchofiberscopy, small-cell and epidermoid cancers, etc., had higher rates of impairment and more severe impairment. Many patients with impaired lungs had a worse prognosis, but patients in whom scintigraphy showed improvement after radiotherapy had a better prognosis. It can be concluded that pulmonary scintigraphy scoring is capable of semiquantitatively indicating the degree of pulmonary impairment and is useful in deciding on a radiotherapeutic plan and predicting the outcome in pre- and post-radiotherapy lung cancer patients. (author)

  5. Procedure guideline for thyroid scintigraphy (version 3)

    International Nuclear Information System (INIS)

    Dietlein, M.; Schicha, H.; Eschner, W.; Deutsche Gesellschaft fuer Medizinische Physik; Koeln Univ.; Leisner, B.; Allgemeines Krankenhaus St. Georg, Hamburg; Reiners, C.; Wuerzburg Univ.

    2007-01-01

    The version 3 of the procedure guideline for thyroid scintigraphy is an update of the procedure guideline previously published in 2003. The interpretation of the scintigraphy requires the knowledge of the patients' history, the palpation of the neck, the laboratory parameters and of the sonography. The interpretation of the technetium-99m uptake requires the knowledge of the TSH-level. As a consequence of the improved alimentary iodine supply the 99m Tc-uptake has decreased; 100 000 counts per scintigraphy should be acquired. For this, an imaging time of 10 minutes is generally needed using a high resolution collimator for thyroid imaging. (orig.)

  6. Esophageal scintigraphy: A comparison with esophagoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kjellen, G.; Andersson, P.; Sandstroem, S.

    1987-01-01

    Fifty consecutive patients with different esophageal symtoms were investigated with esophageal endoscopy, transit scintigraphy, and gastroesophageal (GE) scintigraphy with extra-abdominal compression. Scintigraphic findings were abnormal in 27 of those 31 patients (87%) who were classified as abnormal at endoscopy. A prolonged transit time was the commonest finding, but hiatal hernia and GE reflux were also found. However, the scintigraphic procedure showed abnormalities in 6 of 19 (31%) patients who were classified as normal at endoscopy. Esophageal scintigraphy is recommended as a screening test before endoscopy is decided on. 20 refs.

  7. Baseline Tc-99m DTPA renal scintigraphy as a predictor of outcome in children with urinary tract infection

    Energy Technology Data Exchange (ETDEWEB)

    Yun, J. G.; An, Y. S.; Lee, M. H.; Cho, C. W.; Yun, S. N.; Pai, G. S [Ajou University Medical Center, Suwon (Korea, Republic of)

    2004-07-01

    Tc-99m DTPA renal scintigraphy is useful in detecting urinary tract obstruction in patients with urinary tract infection (UTI). We evaluated the prognostic significance of baseline Tc-99m DTPA renal scintigraphy in children with UTI. Among children, who underwent both baseline/follow-up Tc-99m DMSA scintigraphies and baseline Tc-99m DTP A scintigraphy for evaluation of UTI, 32 patients with unilateral cortical defects on baseline Tc-99m DMSA scintigraphy were included in the study. The outcome of cortical defects was evaluated on follow-up Tc-99m DMSA scintigraphy by visual analysis. ROIs were drawn on the Tc-99m DPTA scintigraphy for calculation of ipsilateral to contralateral kidney ratio (ICR) at blood flow phase (< 60s, BFP) and cortical uptake phase (1-5 min, CUP). Median follow-up period of Tc-99m DMSA scintigraphy was 3.2 months (1.4 - 14 months). There were 24 patients with healing cortical defects and 8 with cortical scarring. Average ICRs of patients with healing defects were 1.11 {+-} 0.18 (0.44 - 1.57) at BFP and 0.97 {+-} 0.21 (0.31 - 1.28) at CUP, while those of patients with cortical scarring were 0.97 {+-} 0.47 (0.21 - 0.89) at BFP and 0.75 {+-} 0.49 (0.19 - 1.65) at CUP. ICR more than 0.9 was determined as a good prognostic indicator. The sensitivity, specificity, positive predictive value, and negative predictive value of ICR was 83.3%, 100%, 100% and 66.7% at BFP, and 79.0%, 62.5%, 86.4% and 50.0% at CUP. Ipsilateral to contralateral kidney ratio on baseline Tc-99m DPTA renal scintigraphy, especially at blood flow phase, is helpful in predicting outcome of children with UTI.

  8. Baseline Tc-99m DTPA renal scintigraphy as a predictor of outcome in children with urinary tract infection

    International Nuclear Information System (INIS)

    Yun, J. G.; An, Y. S.; Lee, M. H.; Cho, C. W.; Yun, S. N.; Pai, G. S

    2004-01-01

    Tc-99m DTPA renal scintigraphy is useful in detecting urinary tract obstruction in patients with urinary tract infection (UTI). We evaluated the prognostic significance of baseline Tc-99m DTPA renal scintigraphy in children with UTI. Among children, who underwent both baseline/follow-up Tc-99m DMSA scintigraphies and baseline Tc-99m DTP A scintigraphy for evaluation of UTI, 32 patients with unilateral cortical defects on baseline Tc-99m DMSA scintigraphy were included in the study. The outcome of cortical defects was evaluated on follow-up Tc-99m DMSA scintigraphy by visual analysis. ROIs were drawn on the Tc-99m DPTA scintigraphy for calculation of ipsilateral to contralateral kidney ratio (ICR) at blood flow phase (< 60s, BFP) and cortical uptake phase (1-5 min, CUP). Median follow-up period of Tc-99m DMSA scintigraphy was 3.2 months (1.4 - 14 months). There were 24 patients with healing cortical defects and 8 with cortical scarring. Average ICRs of patients with healing defects were 1.11 ± 0.18 (0.44 - 1.57) at BFP and 0.97 ± 0.21 (0.31 - 1.28) at CUP, while those of patients with cortical scarring were 0.97 ± 0.47 (0.21 - 0.89) at BFP and 0.75 ± 0.49 (0.19 - 1.65) at CUP. ICR more than 0.9 was determined as a good prognostic indicator. The sensitivity, specificity, positive predictive value, and negative predictive value of ICR was 83.3%, 100%, 100% and 66.7% at BFP, and 79.0%, 62.5%, 86.4% and 50.0% at CUP. Ipsilateral to contralateral kidney ratio on baseline Tc-99m DPTA renal scintigraphy, especially at blood flow phase, is helpful in predicting outcome of children with UTI

  9. Diagnosis of thyroid lymphoma and follow-up evaluation using Ga-67 scintigraphy

    International Nuclear Information System (INIS)

    Nishiyama, Yoshihiro; Yamamoto, Yuka; Yokoe, Koiku; Satoh, Katashi; Ohkawa, Motoomi

    2003-01-01

    A strong association between malignant lymphoma and Hashimoto's thyroiditis has frequently been reported. However, it is difficult to detect the lymphomatous transformation of Hashimoto's thyroiditis in the early stage. The purpose of the present study was to examine the usefulness of 67 Ga scintigraphy in the diagnosis and evaluation of the therapeutic effects during follow-up, in patients with a suspected diagnosis of primary thyroid lymphoma. Twenty-five patients who were suspected of having primary thyroid lymphoma and had undergone 67 Ga scintigraphy were studied. 67 Ga planar scintigraphy was performed 72 hours after injection of 67 Ga-citrate. The degree and pattern of 67 Ga accumulation were graded visually. Histopathology on biopsy examination revealed thyroid lymphoma in 17 and Hashimoto's thyroiditis in 8 patients. Abnormal accumulation of 67 Ga in the thyroid was seen in all of the 17 thyroid lymphoma cases with additional mediastinal and abdominal involvement in one. Fifteen of 17 thyroid lymphoma patients also underwent 67 Ga scintigraphy 2-4 weeks after chemotherapy and/or radiotherapy. All 15 patients showed diminishing 67 Ga accumulation and a good clinical course. In one patient with local recurrence, abnormal accumulation could be depicted by follow-up scintigraphy. However, diffuse or enlarged accumulation in the thyroid was seen in all of the 8 Hashimoto's thyroiditis cases. The degree of abnormal accumulation in the thyroid in clinically active phase thyroiditis was more intense than that in the chronic phase thyroiditis. 67 Ga scintigraphy was helpful to confirm the diagnosis of thyroid lymphoma and to evaluate the therapeutic effects during follow-up. However, 67 Ga scintigraphy may not always distinguish thyroid lymphoma from Hashimoto's thyroiditis, especially the active phase of the disease. (author)

  10. The value of scintigraphy in skeleton diagnostics

    International Nuclear Information System (INIS)

    Wickenhauser, J.

    1976-01-01

    The complex topic of diagnostics of the numerous skeleton diseases was enriched by nuclear medicine, for it is now possible to complete the static picture of morphologic changes resulting from radiologic examinations by its functional component, shown in scintigraphy. This shows that maximal information can only be obtained if the results of skeleton scintigraphy are, according to their importance, integrated into the total picture of the diagnostical decision procedure the centre of which is taken by radiology as was always the case. Because of the different results they lead to, none of the methods can be replaced by another, but they can only complete one another. For the reasons mentioned, the isolated use of skeleton scintigraphy, as it is usual in many places, does not seem not purposeful. Using 8 cases, the author tried to show the problems of skeleton scintigraphy and its position in the diagnostical decision procedure in osteology. (orig.) [de

  11. Guidelines for MIBG-scintigraphy in children

    International Nuclear Information System (INIS)

    Olivier, P.; Colarinha, P.; Fettich, J.; Fischer, S.; Hahn, K.; Porn, U.; Froekier, J.; Giammarile, F.; Gordon, I.; Kabasakal, L.; Mann, M.; Mitjavila, M.; Piepsz, A.; Sixt, R.; Velzen, J. van

    2002-01-01

    These ''Empfehlungen'' are the german translation of the Guidelines on MIBG-Scintigraphy in Children, which were published by the Paediatric Committee of the European Association of Nuclear Medicine. (orig.) [de

  12. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    Science.gov (United States)

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  13. Radionuclide bone scintigraphy in pediatric orthopedics

    International Nuclear Information System (INIS)

    Conway, J.J.

    1986-01-01

    Radionuclide bone scintigraphy is highly sensitive and specific for diagnosing the musculoskeletal disorders of childhood. Conditions such as neonatal osteomyelitis, septic arthritis, diskitis of childhood, Legg-Calve-Perthes disease, the osteochondroses, the toddler's fracture, sports injuries, spondylolysis, myositis ossificians, and reflex sympathetic dystrophy are readily defined. High-quality state-of-the-art scintigraphy is essential in infants and young children. 64 references

  14. Radionuclide bone scintigraphy in pediatric orthopedics

    Energy Technology Data Exchange (ETDEWEB)

    Conway, J.J.

    1986-12-01

    Radionuclide bone scintigraphy is highly sensitive and specific for diagnosing the musculoskeletal disorders of childhood. Conditions such as neonatal osteomyelitis, septic arthritis, diskitis of childhood, Legg-Calve-Perthes disease, the osteochondroses, the toddler's fracture, sports injuries, spondylolysis, myositis ossificians, and reflex sympathetic dystrophy are readily defined. High-quality state-of-the-art scintigraphy is essential in infants and young children. 64 references.

  15. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases. Cintigrafia de ventialacao pulmonar por aerosol em diversas patologias pulmonares

    Energy Technology Data Exchange (ETDEWEB)

    Martins, L R; Marioni Filho, H [Instituto Dante Pazzanese de Cardiologia, Sao Paulo, SP (Brazil); Romaldini, H; Uehara, C; Alonso, G [Escola Paulista de Medicina, Sao Paulo, SP (Brazil)

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author).

  16. Contribution of the Technetium-99m-sestamibi (MIBI) scintigraphy in primary hyperparathyroidism to determination of parathyroidectomy

    International Nuclear Information System (INIS)

    Nishida, Takuro; Hayakawa, Katsumi; Nishimura, Kazumasa; Kawakami, Satoshi; Sakamoto, Makoto; Koh, Toshikiyo; Hida, Shuichi

    1999-01-01

    We reviewed retrospectively the 12 patients who underwent parathyroidectomy because of hyperparathyroidism and judged to what degree the Technetium-99m-sestamibi (MIBI) scintigraphy contributed to determination of parathyroidectomy. From the view point that weather parathyroidectomy could be decided without the MIBI scintigraphy, we classified the cases into three groups; great, fair, and poor contribution. We judged 4 cases as great contribution, 5 cases as fair contribution and 3 cases as poor contribution. We concluded that if the MIBI scintigraphy is positive in patients with primary hyperparathyroidism, parathyroidectomy is strongly recommended, because of its high sensitivity and accuracy for detection of parathyroid adenomas and because there were no false-positive cases with the MIBI scintigraphy. (author)

  17. Correlation of scintigraphy with short interval autopsy in malignant focal liver disease. A study of 59 cases

    International Nuclear Information System (INIS)

    Ruiter, D.J.; Byck, W.; Pauwels, E.K.J.; Taconis, W.K.; Spaander, P.J.

    1977-01-01

    The accuracy of scintigraphy in focal liver disease was evaluated by comparing the scintigraphic and autopsy findings in 59 patients. The interval between scintigraphy and autopsy was not more than a few weeks. The overall agreement rate was 49 in 59 (83 percent), with four out of 26 (15 percent) false positive and six out of 33 (18 percent) false negative reports. Defects smaller than 2 1 / 2 cm were the principal source of false negative reports. The accuracy of interpretation in cases with liver weights up to 2000 g was significantly (P less than 0.025) lower than for higher weights. Detection of a single focal lesion by scintigraphy was found to be unreliable (only two out of 13 correct). Estimation of spleen weights by scintigraphy was disappointing. Liver weight estimates were somewhat more satisfactory

  18. Dynamic renal scintigraphy at hydronephrosis

    International Nuclear Information System (INIS)

    Petrov, T.; Chukov, I.; Svrakova, E.

    1998-01-01

    The aim of the study was to estimate the clinical relevance and accuracy of dynamic renal scintigraphy (DRS) in case of obstructed kidneys as hydronephrosis is among the complications at different renal diseases, like nephrolithiasis and urolithiasis. Twenty-one patients mainly with unilateral hydronephrosis were studied. DRS with 99m Tc-MAG3 or 99m Tc-EC was done and quantitative parameters of the morphological and functional status of every kidney were assessed. At 24 % of the patients accumulation curves typical for obstructed by hydronephrosis kidneys were obtained. At 38 % the type of renograms of the affected kidneys was intermediate one, closer to that at the cases with nephrosclerosis, with lower uptake and severe parenchymal changes. The rest 38 % of the cases showed normal renograms or slightly delayed downslope. DRS is a very precise and sensitive method for evaluation of the degree of kidney damage in cases with hydronephrosis

  19. Scintigraphy in benign thyroid disorders

    International Nuclear Information System (INIS)

    Mahlstedt, J.

    2004-01-01

    For diagnosis, therapy and prognosis of benign thyroidal disorders thyroidal scintigraphy has to be seen in full strength in relation to thyroid hormone metabolism and regulation. Thyroidal iodine avidity can easily be assessed by TcTU ( 99m Tc-thyroid-up-take 20 min p.inj.), as the well known standard measure for the service of goiter patients. TcTU and TSH show concordance, i.e. direct correlation, when thyroid regulation is intact, however there is no correlation, i.e. discordance, in disorders such as destruction, autonomy oder immunogenic stimulation. The strategy to evaluate concordance/discordance of TcTU and TSH in outpatient routine work (''one stop shop'') is demonstrated in a variety of clinical situations being not always conform to current guide lines and recommendations. (orig.)

  20. Detection of impaired diastolic relaxation during myocardial ischemia using x-ray scatter fields

    International Nuclear Information System (INIS)

    McInerney, J.J.; Morris, L.; Herr, M.D.; Copenhaver, G.L.

    1986-01-01

    Precise three-dimensional epicardial displacements and velocities are measured nonivasively (no cutdowns or injections) with low-energy x-rays scattered from the closed chest surface of the heart. Surface reconstructions provide direct visualization of p-wave motion of the atrial wall, isovolumic sphericalization of the heart, global thrust of the ventricle during ejection, swelling of the base during refill, and relaxation during diastole. This new imaging technique was applied to canines before and after closed chest coronary embolization. Displacement and velocity displays of ischemic hearts clearly show reduced ejection displacement amplitudes, asynchronous motion patterns during systole, and impaired relaxation patterns during diastole

  1. On the Optimal Detection and Error Performance Analysis of the Hardware Impaired Systems

    KAUST Repository

    Javed, Sidrah; Amin, Osama; Ikki, Salama S.; Alouini, Mohamed-Slim

    2018-01-01

    The conventional minimum Euclidean distance (MED) receiver design is based on the assumption of ideal hardware transceivers and proper Gaussian noise in communication systems. Throughout this study, an accurate statistical model of various hardware impairments (HWIs) is presented. Then, an optimal maximum likelihood (ML) receiver is derived considering the distinct characteristics of the HWIs comprised of additive improper Gaussian noise and signal distortion. Next, the average error probability performance of the proposed optimal ML receiver is analyzed and tight bounds are derived. Finally, different numerical and simulation results are presented to support the superiority of the proposed ML receiver over MED receiver and the tightness of the derived bounds.

  2. On the Optimal Detection and Error Performance Analysis of the Hardware Impaired Systems

    KAUST Repository

    Javed, Sidrah

    2018-01-15

    The conventional minimum Euclidean distance (MED) receiver design is based on the assumption of ideal hardware transceivers and proper Gaussian noise in communication systems. Throughout this study, an accurate statistical model of various hardware impairments (HWIs) is presented. Then, an optimal maximum likelihood (ML) receiver is derived considering the distinct characteristics of the HWIs comprised of additive improper Gaussian noise and signal distortion. Next, the average error probability performance of the proposed optimal ML receiver is analyzed and tight bounds are derived. Finally, different numerical and simulation results are presented to support the superiority of the proposed ML receiver over MED receiver and the tightness of the derived bounds.

  3. One-Year Effect of the Medicare Annual Wellness Visit on Detection of Cognitive Impairment: A Cohort Study.

    Science.gov (United States)

    Fowler, Nicole R; Campbell, Noll L; Pohl, Gerhardt M; Munsie, Leanne M; Kirson, Noam Y; Desai, Urvi; Trieschman, Erich J; Meiselbach, Mark K; Andrews, J Scott; Boustani, Malaz A

    2018-04-02

    To examine the effect of the Medicare Annual Wellness Visit (AWV) on the detection of cognitive impairment and on follow-up cognitive care for older adults. Retrospective matched-cohort study. United States. A 5% random sample of fee-for-service Medicare beneficiaries continuously enrolled for 12 months before and after an index ambulatory visit occurring from 2011 to 2013 with no claims evidence of cognitive impairment before index. Outcomes include 12-month post-index visit claims-based measurements of cognitive impairment, including new Alzheimer's disease and related dementia (ADRD) diagnoses; medications for ADRD; and cognitive care-related diagnostic examination such as neurobehavioral testing, brain imaging, and blood tests for thyroid-stimulating hormone (TSH), serum B12, folate, and syphilis. We also measured changes in burden of anticholinergic medication. There were no clinically relevant differences between the AWV and control groups in the rates of incident ADRD diagnoses (6.16% vs 6.86%, p<.001) and initiation of ADRD medications (1.00% vs 1.08%, p=.15), although there were differences favoring the AWV group in rates of TSH (39.80% vs 28.36%, p<.001), B12 (9.41% vs 6.97%, p<.001), folate (4.76% vs 3.72%, p<.001), and neurobehavioral (0.75% vs 0.55%, p<.001) testing. Although the AWV is correlated with an increase in some measures of cognitive care, such as laboratory testing for reversible causes of cognitive impairment, it does not appear to substantially increase recognition of undetected ADRD. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.

  4. Antimyosin scintigraphy in patients with acquired and hereditary muscular disorders

    International Nuclear Information System (INIS)

    Loefberg, M.; Liewendahl, K.; Savolainen, S.; Nikkinen, P.; Lamminen, A.; Tiula, E.; Somer, H.

    1994-01-01

    Scintigraphy with indium-111 labelled antimyosin has an established role in the evaluation of cardiac muscle damage. This antibody has been shown to cross-react with myosin in skeletal muscle. We therefore studied the usefulness of this method for the detection of skeletal muscle lesions in rhabdomyolysis, myositis and hereditary muscular dystrophies. All nine patients with rhabdomyolysis had focal uptake of antimyosin antibody which correlated with the clinical findings of soft tissue damage. However, a number of symptomless lesions were also detected by immunoscintigraphy. In rhabdomyolysis the target to non-target uptake ratios varied from 1.3 to 7.6. Diffuse uptake of antibody in skeletal muscle was observed in all three patients with polymyositis-dermatomyositis and in 12 out of 13 patients with muscular dystrophies. In myositis the intensity of antibody accumulation correlated reasonably well with the magnitude of oedema detected by magnetic resonance imaging (MRI). Most patients with Becker type or non-X-chromosomal muscular dystrophies showed slight or moderate uptake of antibody, mainly in the lower extremities. In these patients more antibody accumulated in the calves than in the thighs, whereas the findings on MRI were more prominent in the thighs than in the calves, presumably because of the better preserved muscle bulk in the calves. We conclude that antimyosin scintigraphy can be used for the detection of muscle lesions not only in acquired muscle diseases but also in hereditary muscular disorders, and that immunoscintigraphy provides information on muscle disease activity not obtainable with MRI. (orig.)

  5. Antimyosin scintigraphy in patients with acquired and hereditary muscular disorders

    Energy Technology Data Exchange (ETDEWEB)

    Loefberg, M. (Dept. of Neurology, Helsinki Univ. Central Hospital (Finland)); Liewendahl, K. (Dept. of Clinical Chemistry, Helsinki Univ. Central Hospital (Finland)); Savolainen, S. (Dept. of Clinical Chemistry, Helsinki Univ. Central Hospital (Finland)); Nikkinen, P. (Dept. of Clinical Chemistry, Helsinki Univ. Central Hospital (Finland)); Lamminen, A. (Dept. of Radiology, Helsinki Univ. Central Hospital (Finland)); Tiula, E. (First Dept. of Internal Medicine, Helsinki Univ. Central Hospital (Finland)); Somer, H. (Dept. of Neurology, Helsinki Univ. Central Hospital (Finland))

    1994-10-01

    Scintigraphy with indium-111 labelled antimyosin has an established role in the evaluation of cardiac muscle damage. This antibody has been shown to cross-react with myosin in skeletal muscle. We therefore studied the usefulness of this method for the detection of skeletal muscle lesions in rhabdomyolysis, myositis and hereditary muscular dystrophies. All nine patients with rhabdomyolysis had focal uptake of antimyosin antibody which correlated with the clinical findings of soft tissue damage. However, a number of symptomless lesions were also detected by immunoscintigraphy. In rhabdomyolysis the target to non-target uptake ratios varied from 1.3 to 7.6. Diffuse uptake of antibody in skeletal muscle was observed in all three patients with polymyositis-dermatomyositis and in 12 out of 13 patients with muscular dystrophies. In myositis the intensity of antibody accumulation correlated reasonably well with the magnitude of oedema detected by magnetic resonance imaging (MRI). Most patients with Becker type or non-X-chromosomal muscular dystrophies showed slight or moderate uptake of antibody, mainly in the lower extremities. In these patients more antibody accumulated in the calves than in the thighs, whereas the findings on MRI were more prominent in the thighs than in the calves, presumably because of the better preserved muscle bulk in the calves. We conclude that antimyosin scintigraphy can be used for the detection of muscle lesions not only in acquired muscle diseases but also in hereditary muscular disorders, and that immunoscintigraphy provides information on muscle disease activity not obtainable with MRI. (orig.)

  6. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  7. Radionuclide Esophageal Transit Scintigraphy in Primary Hypothyroidism.

    Science.gov (United States)

    Khan, Shoukat H; P, Madhu Vijay; Rather, Tanveer A; Laway, Bashir A

    2017-01-30

    Esophageal dysmotility is associated with gastrointestinal dysmotility in various systemic and neuroregulatory disorders. Hypothyroidism has been reported to be associated with impaired motor function in esophagus due to accumulation of glycosaminoglycan hyaluronic acid in its soft tissues, leading to changes in various contraction and relaxation parameters of esophagus, particularly in the lower esophageal sphincter. In this study we evaluated esophageal transit times in patients of primary hypothyroidism using the technique of radionuclide esophageal transit scintigraphy. Thirty-one patients of primary hypothyroidism and 15 euthyroid healthy controls were evaluated for esophageal transit time using 15-20 MBq of Technetium-99m sulfur colloid diluted in 10-15 mL of drinking water. Time activity curve was generated for each study and esophageal transit time was calculated as time taken for clearance of 90% radioactive bolus from the region of interest encompassing the esophagus. Esophageal transit time of more than 10 seconds was considered as prolonged. Patients of primary hypothyroidism had a significantly increased mean esophageal transit time of 19.35 ± 20.02 seconds in comparison to the mean time of 8.25 ± 1.71 seconds in healthy controls ( P < 0.05). Esophageal transit time improved and in some patients even normalized after treatment with thyroxine. A positive correlation ( r = 0.39, P < 0.05) albeit weak existed between the serum thyroid stimulating hormone and the observed esophageal transit time. A significant number of patients with primary hypothyroidism may have subclinical esophageal dysmotility with prolonged esophageal transit time which can be reversible by thyroxine treatment. Prolonged esophageal transit time in primary hypothyroidism may correlate with serum thyroid stimulating hormone levels.

  8. Utility and limitations of Addenbrooke's Cognitive Examination-Revised for detecting mild cognitive impairment in Parkinson's disease.

    Science.gov (United States)

    Komadina, Natalie C; Terpening, Zoe; Huang, Yue; Halliday, Glenda M; Naismith, Sharon L; Lewis, Simon J G

    2011-01-01

    To evaluate the utility of the Addenbrooke's Cognitive Examination-Revised (ACE-R) as a screening tool for mild cognitive impairment in Parkinson's disease (PD-MCI). PD patients underwent comprehensive neuropsychological and neurological evaluations and ACE-R assessment. The ACE-R was superior to the Mini-Mental State Exam (MMSE) in detecting PD-MCI, with a cutoff score of ≤93 offering a sensitivity of 61% and a specificity of 64%. The utility of the ACE-R in detecting PD-MCI is largely influenced by the fluency sub-domain score, and has optimal discriminability when utilized in patients with lower levels of education (≤12 years of formal schooling). The ACE-R must be used cautiously as a screening tool for PD-MCI, with results being most influenced by its fluency sub-domain score and patient education levels. Copyright © 2011 S. Karger AG, Basel.

  9. Abdominal blood pool scintigraphy in the management of acute or intermittent gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Kalff, V.; Kelly, M.J.; Dudley, F.; Metz, G.

    1983-01-01

    Gastrointestinal blood pool scintigraphy, using a modified in-vivo blood cell labelling technique with technetium-99, is a new, easily performed, non-invasive procedure. It is valuable in screening patients with acute or intermittent gastrointestinal blood loss in whom duodenoscopic and sigmoidoscopic findings are unhelpful. This paper reviews the value of this scintigraphic technique over the first eight months of its use in a major teaching hospital, and compares the results with other published data. If used and interpreted appropriately, scintigraphy is sensitive in detecting and localizing the bleeding site, and is very helpful in indicating the optimal timing of emergency contrast angiography

  10. sup 99m Tc-sucralfate scintigraphy in inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, P.B.; Lech, Y.; Moeller-Petersen, J.; Vilien, M.; Fallingborg, J. (Aalborg Sygehus (Denmark)); Ekelund, S. (Copenhagen County Hospital (Denmark))

    1989-01-01

    Technetium-99m-labelled albumin-sucralfate was orally administered to 11 patients (Crohn's disease, 8; ulcerative colitis, 3) and 3 healthy volunteers. Serial scintigraphy was performed, and scintigraphic interpretations were compared with radiographic end endoscopic findings in an open study. It was not possible in any patient to relate the scintigraphic findings to the localizations of inflammatory bowel disease, nor was it possible to distinguish the scans in the patients from the scans of the healthy volunteers. It is concluded the {sup 99m}Tc-albumin-sucralfate scintigraphy is of no value in the detection of inflammatory bowel disease. 8 refs.

  11. 201Tl myocard scintigraphy - a specialized non-invasive method in evaluating myocardial function

    International Nuclear Information System (INIS)

    Birke, S.; Deckart, H.; Mischke, W.; Schulz, J.; Koblitz, E.

    1985-01-01

    In 216 patients with ischemic heart disease (IHK) or with angina pectoris symptoms and suspected IHK the results of resting electrocardiograms were compared with those of 201 Tl scintigraphy under conditions of rest and exercise, resp. 201 Tl scintigraphy proved to be superior in sensitivity and specifity to the electrocardiograms of rest and under exercise as to the detection of coronary heart disease, the localization and assessment of the severity of coronary heart disease, and the evidence of load ischemia. Conclusions are drawn for a program of consecutive diagnostic steps in suspected IHK as well as for the evaluation of myocardial function in known IHK. (author)

  12. Strategy for use of biliary scintigraphy in non-iatrogenic biliary trauma

    International Nuclear Information System (INIS)

    Zeman, R.K.; Lee, C.H.; Stahl, R.; Viscomi, G.N.; Baker, C.; Cahow, C.E.; Dobbins, J.; Neumann, R.; Burrell, M.I.

    1984-01-01

    Biliary scintigraphy was used to examine 21 patients who had suspected non-iatrogenic biliary trauma. Seven patients (33%) had scintigraphic evidence of biliary leakage. Ultimately, surgical biliary repair was required for only three of these patients. Visualization of the gallbladder did not occur in eight trauma patients, but only one patient was shown to have cholecystitis. In this series, 16 patients had Tc-99m sulfur colloid scans that offered no significant advantage over cholescintigraphy in the detection of hepatic parenchymal defects. Biliary scintigraphy provides clinically useful information in cases both of blunt and penetrating trauma

  13. Strategy for the use of biliary scintigraphy in non-iatrogenic biliary trauma

    International Nuclear Information System (INIS)

    Zeman, R.K.; Lee, C.H.; Stahl, R.; Viscomi, G.N.; Baker, C.; Cahow, C.E.; Dobbins, J.; Neumann, R.; Burrell, M.I.

    1984-01-01

    Biliary scintigraphy was used to examine 21 patients who had suspected non-iatrogenic biliary trauma. Seven patients (33%) had scintigraphic evidence of biliary leakage. Ultimately, surgical biliary repair was required for only three of these patients. Visualization of the gallbladder did not occur in eight trauma patients, but only one patient was shown to have cholecystitis. In this series, 16 patients had Tc-99m sulfur colloid scans that offered no significant advantage over cholescintigraphy in the detection of hepatic parenchymal defects. Biliary scintigraphy provides clinically useful information in cases both of blunt and penetrating trauma

  14. Parathyroid localizlation by 201Tl-99mTc subtraction scintigraphy

    International Nuclear Information System (INIS)

    Rademaker, P.; Meijer, S.; Piers, D.A.

    1990-01-01

    Subtraction scintigraphy with 201 Tl and 99m Tc for parathyroid localization was performed preoperatively in 13 patients with chronic renal failure and secondary hyperparathyroidism. Twenty of the 37 examined pathological glands were predicted correctly (sensitivity 54%). In 3 patients with recurrent hyperparathyroidism after surgery all pathological glands found at second operation had been detected correctly by subtraction scintigraphy. We conclude that this localization method has a limited value when used prior to first neck exploration in secondary hyperparathyroidism. In persistent hyperparathyroidism after surgery it may play a useful role in localizing missed and ectopic glands. (author)

  15. Sensitivity of cortical auditory evoked potential detection for hearing-impaired infants in response to short speech sounds

    Directory of Open Access Journals (Sweden)

    Bram Van Dun

    2012-01-01

    Full Text Available

    Background: Cortical auditory evoked potentials (CAEPs are an emerging tool for hearing aid fitting evaluation in young children who cannot provide reliable behavioral feedback. It is therefore useful to determine the relationship between the sensation level of speech sounds and the detection sensitivity of CAEPs.

    Design and methods: Twenty-five sensorineurally hearing impaired infants with an age range of 8 to 30 months were tested once, 18 aided and 7 unaided. First, behavioral thresholds of speech stimuli /m/, /g/, and /t/ were determined using visual reinforcement orientation audiometry (VROA. Afterwards, the same speech stimuli were presented at 55, 65, and 75 dB SPL, and CAEP recordings were made. An automatic statistical detection paradigm was used for CAEP detection.

    Results: For sensation levels above 0, 10, and 20 dB respectively, detection sensitivities were equal to 72 ± 10, 75 ± 10, and 78 ± 12%. In 79% of the cases, automatic detection p-values became smaller when the sensation level was increased by 10 dB.

    Conclusions: The results of this study suggest that the presence or absence of CAEPs can provide some indication of the audibility of a speech sound for infants with sensorineural hearing loss. The detection of a CAEP provides confidence, to a degree commensurate with the detection probability, that the infant is detecting that sound at the level presented. When testing infants where the audibility of speech sounds has not been established behaviorally, the lack of a cortical response indicates the possibility, but by no means a certainty, that the sensation level is 10 dB or less.

  16. The neural substrates of impaired prosodic detection in schizophrenia and its sensorial antecedents.

    Science.gov (United States)

    Leitman, David I; Hoptman, Matthew J; Foxe, John J; Saccente, Erica; Wylie, Glenn R; Nierenberg, Jay; Jalbrzikowski, Maria; Lim, Kelvin O; Javitt, Daniel C

    2007-03-01

    Individuals with schizophrenia show severe deficits in their ability to decode emotions based upon vocal inflection (affective prosody). This study examined neural substrates of prosodic dysfunction in schizophrenia with voxelwise analysis of diffusion tensor magnetic resonance imaging (MRI). Affective prosodic performance was assessed in 19 patients with schizophrenia and 19 comparison subjects with the Voice Emotion Identification Task (VOICEID), along with measures of basic pitch perception and executive processing (Wisconsin Card Sorting Test). Diffusion tensor MRI fractional anisotropy valves were used for voxelwise correlation analyses. In a follow-up experiment, performance on a nonaffective prosodic perception task was assessed in an additional cohort of 24 patients and 17 comparison subjects. Patients showed significant deficits in VOICEID and Distorted Tunes Task performance. Impaired VOICEID performance correlated significantly with lower fractional anisotropy values within primary and secondary auditory pathways, orbitofrontal cortex, corpus callosum, and peri-amygdala white matter. Impaired Distorted Tunes Task performance also correlated with lower fractional anisotropy in auditory and amygdalar pathways but not prefrontal cortex. Wisconsin Card Sorting Test performance in schizophrenia correlated primarily with prefrontal fractional anisotropy. In the follow-up study, significant deficits were observed as well in nonaffective prosodic performance, along with significant intercorrelations among sensory, affective prosodic, and nonaffective measures. Schizophrenia is associated with both structural and functional disturbances at the level of primary auditory cortex. Such deficits contribute significantly to patients' inability to decode both emotional and semantic aspects of speech, highlighting the importance of sensorial abnormalities in social communicatory dysfunction in schizophrenia.

  17. Diagnostic capabilities of quantitative bone scintigraphy in ankylosing spondylitis: A comparison with radiography

    International Nuclear Information System (INIS)

    Mlatschkov, C.; Mlatschkova, D.; Andreev, T.

    1989-01-01

    In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with 99m Tc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral metabolism of the sacroiliac joints and the spinal cord. Skeletal scintigraphy is recommended for early detection and monitoring of ankylosing spondylitis. (author)

  18. Changes in respiratory function impairment following the treatment of severe pulmonary tuberculosis - limitations for the underlying COPD detection.

    Science.gov (United States)

    Radovic, Milan; Ristic, Lidija; Ciric, Zorica; Dinic-Radovic, Violeta; Stankovic, Ivana; Pejcic, Tatjana; Rancic, Milan; Bogdanovic, Dragan

    2016-01-01

    During the treatment phase of active pulmonary tuberculosis (PTB), respiratory function impairment is usually restrictive. This may become obstructive, as a PTB-associated airflow obstruction (AFO) or as a later manifestation of underlying COPD. The aim of the study was to examine the potential causes and risks for AFO development in PTB by exploring the aspects of spirometry limitations and clinical implications for the underlying COPD detection, taking into account various confounding factors. Prospective, nest case-control study on 40 new cases of PTB with initial restrictive respiratory function impairment, diagnosed and treated according to the directly observed treatment short course (DOTS) strategy. From all observed patients, 37.5% of them developed AFO upon the completion of PTB treatment, with significantly increased average of forced vital capacity (%) (Ppulmonary tuberculosis lesions (OR 1.01-1.05 for 95% CI; P=0.02) and sputum conversion rate on culture (OR 1.02-1.68 for 95% CI; P=0.04) as the most significant predictors for the risk of AFO development. AFO upon PTB treatment is a common manifestation of underlying COPD, which mostly occurs later, during the reparative processes in active PTB, even in the absence of major risk factors, such as cigarette smoking and biomass fuel dust exposure. Initial spirometry testing in patients with active PTB is not a sufficient and accurate approach in the detection of underlying COPD, which may lead to their further potential health deterioration.

  19. Radiospirometry and perfusion scintigraphy in cases of limited pulmonary fibrosis

    International Nuclear Information System (INIS)

    Tarkowska, A.; Smajkiewicz, L.; Szarewicz-Adamczyk, W.; Zaorska-Rajca, J.; Woytowicz, A.; Patyra, S.

    1981-01-01

    In 60 cases of limited pulmonary fibrosis radiospirometric investigation was performed using 133 Xe and a four-channel set. Perfusion scintigraphy was done as well after administration of labelled molecules. In all patients abnormalities were found in the results of both isotope methods suggesting presence of disturbances in the regional pulmonary functions. These disturbances included impairment of perfusion as well as ventilation, with evidence of obturation, increased volume of residual air, and decreased vital and total capasity of the lungs. These abnormalities occurred exclusively or most intensively in the areas corresponding to the location of the anatomical change, and in a considerable proportion of cases they were more extensive than the radiological changes. In about 40% of the patients in the contralateral lung diffuse changes of perfusion and ventilation were present, although much less intense, suggesting concomitant chronic obturative disease. The authors think that perfusion scintigraphy and radiospirometry owing to their value as a method of assessing pulmonary function are useful in cases of pulmonary fibrosis for establishing treatment methods and for evaluating disability to work. (author)

  20. Contribution of bone and brain scintigraphy to diagnosis of the extension and nature of skull lesions

    International Nuclear Information System (INIS)

    Akerman, M.; Tovar, G. de; Derome, P.

    The combination of bone and brain scintigraphy provides a vast amount of information in the study of lesions of the skull. It is especially valuable as a means to circumscribe the invasion of the bones, distinguish between bone and intracranial invasion, diagnose the nature of the lesion, estimate its degree of vascularization and detect remote localisations [fr

  1. The clinical utility of indium-111 labelled platelet scintigraphy in the diagnoses of renal transplant rejection

    International Nuclear Information System (INIS)

    Desir, G.V.; Bia, M.; Lange, R.C.; Smith, E.O.; Flye, W.; Kashgarian, M.; Schiff, M.; Ezekowitz, M.D.

    1990-01-01

    It is demonstrated that indium-111 labelled platelet scintigraphy is a highly accurate test for detecting acute untreated renal allograft rejection and it is shown that changes in platelet uptake can precede signs and symptoms of rejection by at least 48 hours. (author). 34 refs.; 2 figs.; 1 tab

  2. Systematic review of cost-effectiveness of myocardial perfusion scintigraphy in patients with ischaemic heart disease

    NARCIS (Netherlands)

    Tragardh, Elin; Tan, Siok Swan; Bucerius, Jan; Gimelli, Alessia; Gaemperli, Oliver; Lindner, Oliver; Agostini, Denis; Uebleis, Christopher; Sciagra, Roberto; Slart, Riemer H.; Underwood, S. Richard; Hyafil, Fabien; Hacker, Marcus; Verberne, Hein J.

    2017-01-01

    Coronary artery disease (CAD) is a major cause of death and disability. Several diagnostic tests, such as myocardial perfusion scintigraphy (MPS), are accurate for the detection of CAD, as well as having prognostic value for the prediction of cardiovascular events. Nevertheless, the diagnostic and

  3. [Myocardial perfusion scintigraphy. Exact and cost-effective coronary disease imaging - secondary publication

    DEFF Research Database (Denmark)

    Hesse, B.; Petersen, C.L.; Marcassa, C.

    2008-01-01

    Mortality rates due to coronary arterial disease (CAD) have declined as result of improved prevention, diagnosis and management, but CAD remains the leading cause of death. Myocardial perfusion scintigraphy (MPS) provides a cost-effective tool for early detection of CAD in symptomatic individuals...

  4. Using local texture maps of brain MR images to detect Mild Cognitive Impairment

    NARCIS (Netherlands)

    Lopes Simoes, Rita; Slump, Cornelis H.; van Cappellen van Walsum, Anne-Marie

    2012-01-01

    Early detection of Alzheimer's disease is expected to aid in the development and monitoring of more effective treatments. Classification methods have been proposed to distinguish Alzheimer's patients from normal controls using Magnetic Resonance Images. However, their performance drops when

  5. Growth inhibitory factors in bovine faeces impairs detection of Salmonella Dublin by conventional culture procedure

    DEFF Research Database (Denmark)

    Baggesen, Dorte Lau; Nielsen, L.R.; Sørensen, Gitte

    2007-01-01

    Aims: To analyse the relative importance of different biological and technical factors on the analytical sensitivity of conventional culture methods for detection of Salmonella Dublin in cattle faeces. Methods and Results: Faeces samples collected from six adult bovines from different salmonella...... novobiocin, followed by combinations of culture media (three types) and selective media (two types). The sensitivity of each combination and sources of variation in detection were determined by a generalized linear mixed model using a split-plot design. Conclusions: Biological factors, such as faecal origin...... and S. Dublin strain influenced the sensitivity more than technical factors. Overall, the modified semisolid Rappaport Vassiliadis (MSRV)-culture medium had the most reliable detection capability, whereas detection with selenite cystine broth and Mueller Kauffman tetrathionate broth combinations varied...

  6. The contribution of bone scintigraphy in occupational health or medical insurance claims: a retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Versijpt, J.; Dierckx, R.A.; Bondt, P. de [Division of Nuclear Medicine, University Hospital Gent (Belgium); Dierckx, I. [Department of Radiology, St. Elisabeth Hospital Antwerpen (Belgium); Lambrecht, L. [Outpatient Internal Medicine Clinic, Gent (Belgium); Sadeleer, C. de [Division of Nuclear Medicine, University Hospital Gent (Belgium)]|[Department of Nuclear Medicine, O.L.V. Hospital Geraardsbergen (Belgium)

    1999-08-01

    Patients with a suspicion of bone damage following an industrial or traffic accident are often referred for bone scintigraphy as part of an occupational health or medical insurance investigation. The aim of this study was to assess the contribution and the potential role of bone scintigraphy compared with X-ray investigations in the aforementioned situation. To this end we evaluated 70 consecutive patients referred for bone scintigraphy during 1996 and 1997 by occupational health or medical insurance physicians. The most common reasons for referral were the exclusion of occult fractures of hands and feet, whiplash injuries, reflex sympathetic dystrophy or avascular necrosis, or the differentiation between an old and a recent vertebral fracture. X-rays were only available for comparative review of 53 patients, so only those were analysed. The results of bone scintigraphy were compared with X-rays, and their contribution and potential role in occupational health or medical insurance investigations assessed. In 31 out of the 53 patients investigated, bone scintigraphy findings concurred with X-rays as to the number and location of abnormalities. For 19 of the 53 patients, bone scintigraphy showed clinically relevant additional foci when compared with X-rays, predominantly involving lesions to hands/wrists and feet/ankles. Among these 19 patients, scintigraphic diagnoses were subsequently confirmed in ten cases by means of X-ray or computed tomography. In four patients, supplementary radiological investigations revealed no abnormalities, and in five patients no further investigations were undertaken. Finally, in three of the 53 patients, X-rays revealed bone damage (burst fractures) whilst the corresponding bone scintigraphy was negative, thus excluding recent injury. In conclusion, in 22 patients, representing 42% of the cases analysed, bone scintigraphy was conclusive compared with X-ray imaging in the final diagnosis and in this way in detecting occult or excluding

  7. The contribution of bone scintigraphy in occupational health or medical insurance claims: a retrospective study

    International Nuclear Information System (INIS)

    Versijpt, J.; Dierckx, R.A.; Bondt, P. de; Dierckx, I.; Lambrecht, L.; Sadeleer, C. de

    1999-01-01

    Patients with a suspicion of bone damage following an industrial or traffic accident are often referred for bone scintigraphy as part of an occupational health or medical insurance investigation. The aim of this study was to assess the contribution and the potential role of bone scintigraphy compared with X-ray investigations in the aforementioned situation. To this end we evaluated 70 consecutive patients referred for bone scintigraphy during 1996 and 1997 by occupational health or medical insurance physicians. The most common reasons for referral were the exclusion of occult fractures of hands and feet, whiplash injuries, reflex sympathetic dystrophy or avascular necrosis, or the differentiation between an old and a recent vertebral fracture. X-rays were only available for comparative review of 53 patients, so only those were analysed. The results of bone scintigraphy were compared with X-rays, and their contribution and potential role in occupational health or medical insurance investigations assessed. In 31 out of the 53 patients investigated, bone scintigraphy findings concurred with X-rays as to the number and location of abnormalities. For 19 of the 53 patients, bone scintigraphy showed clinically relevant additional foci when compared with X-rays, predominantly involving lesions to hands/wrists and feet/ankles. Among these 19 patients, scintigraphic diagnoses were subsequently confirmed in ten cases by means of X-ray or computed tomography. In four patients, supplementary radiological investigations revealed no abnormalities, and in five patients no further investigations were undertaken. Finally, in three of the 53 patients, X-rays revealed bone damage (burst fractures) whilst the corresponding bone scintigraphy was negative, thus excluding recent injury. In conclusion, in 22 patients, representing 42% of the cases analysed, bone scintigraphy was conclusive compared with X-ray imaging in the final diagnosis and in this way in detecting occult or excluding

  8. Regional distribution of ventilation assessed by Kr-81m scintigraphy employing temporal Fourier transform

    International Nuclear Information System (INIS)

    Slosman, D.; Susskind, H.; Cinotti, L.; van Giessen, J.W.; Brill, A.B.

    1986-01-01

    Temporal Fourier analysis was applied to Kr-81m ventilation scintigraphy to determine the amplitude (AMP1) and phase (PHA1) of the first harmonic of a single composite respiratory cycle and to compare regional patterns in subjects with obstructive pulmonary disease (COPD) and nonobstructed subjects. Six nonobstructed subjects, three subjects with small airway disease, six subjects with COPD, and one subject with restrictive disease were investigated. The mean value of the functional PHA1 image (PHA1m) correlated negatively with 1-second forced expiratory volume (FEV1) (r = -0.801, P less than .001), with %FEV1/FVC (r = -0.636, P less than .01) and maximum midexpiratory flow rate (FEF25-75%) (r = -0.723, P less than .002), and correlated positively with residual volume (r = 0.640, P less than .01). PHA1m values for the six subjects with COPD were significantly higher (t = 2.359, P less than .05) than for the ten nonobstructed subjects. Display of phase and amplitude functional images permits a visual evaluation of the regional distribution of ventilation to be made. Regional abnormalities of air flow were detected in obstructed subjects, and the presence of airway obstruction could be predicted. Dynamic ventilation imaging, therefore, appears to be a potentially useful noninvasive technique to assess lung impairment on a localized level

  9. Radiation protect during the ventilation scintigraphy of Tc99m DTPA radioaerosol in pediatric application

    International Nuclear Information System (INIS)

    Chen, Yu-Wen; Dai, Zen-Kong; Huang, Ying-Fong; Jong, Shiang-Bing

    2000-01-01

    Lung ventilation-perfusion scintigraphy is of great value for the management of patients with both primary lung disease and heart disease, by proving patho- physiological information of importance for the diagnosis, follow-up and functional evaluation of the patients. Krypton 81m radioactive gas is preferable for pediatric application due to its short half-life. However, the rubidium-krypton 81m generator is not popular in hospital of our country. Tc99m DTPA radioaerosol ventilation scintigraphy has its unique convenient for clinical application. But, the most disadvantage of clinical application of Tc99m DTPA radioaerosol is contamination of environment when the poor-cooperative patient can't breathe by mouth. For this reason, we design the certain procedure to reduce the radioaerosol contamination. During May to Aug., 1999, we collect 36 pediatric patients (male to female ratio 2:1, age from 6 months to 20 years old) with clinical history of lung or heart disease, including congenital heart disease, asthma and so on. Before the cases receive 10 to 15 mCi Tc99m DTPA radioaerosol ventilation scan, all of them were trained with breath training. And during the ventilation scintigraphy, the special mouth mask is designed to prevent the radioaerosol leakage into atmosphere. Then Geiger-Muller survey meter was arranged to detect the environmental contamination of radioaerosol in the mask, one and two metes away from the mask every 10 minutes during ventilation scintigraphy procedure and 1 hour after finishing image. Two nuclear medicine physicians evaluated imaging quality of ventilation scintigraphy. Results: Among thirty-six pediatric patients with prior breath training, thirty-two cases are successful to proceed the Tc99m DTPA ventilation scintigraphy. The other four cases that were under three-year-old fail to receive ventilation scintigraphy. There is limited detectable radioactivity in the mouth mask at early 10 minute by Geiger-Muller counter. No significant

  10. Detection threshold for sound distortion resulting from noise reduction in normal-hearing and hearing-impaired listeners.

    Science.gov (United States)

    Brons, Inge; Dreschler, Wouter A; Houben, Rolph

    2014-09-01

    Hearing-aid noise reduction should reduce background noise, but not disturb the target speech. This objective is difficult because noise reduction suffers from a trade-off between the amount of noise removed and signal distortion. It is unknown if this important trade-off differs between normal-hearing (NH) and hearing-impaired (HI) listeners. This study separated the negative effect of noise reduction (distortion) from the positive effect (reduction of noise) to allow the measurement of the detection threshold for noise-reduction (NR) distortion. Twelve NH subjects and 12 subjects with mild to moderate sensorineural hearing loss participated in this study. The detection thresholds for distortion were determined using an adaptive procedure with a three-interval, two-alternative forced-choice paradigm. Different levels of distortion were obtained by changing the maximum amount of noise reduction. Participants were also asked to indicate their preferred NR strength. The detection threshold for overall distortion was higher for HI subjects than for NH subjects, suggesting that stronger noise reduction can be applied for HI listeners without affecting the perceived sound quality. However, the preferred NR strength of HI listeners was closer to their individual detection threshold for distortion than in NH listeners. This implies that HI listeners tolerate fewer audible distortions than NH listeners.

  11. Single-photon emission computed tomography enhanced Tc-99m-pertechnetate disodium-labelled red blood cell scintigraphy in the localization of small intestine bleeding: a single-centre twelve-year study.

    Science.gov (United States)

    Dolezal, Jiri; Vizda, Jaroslav; Kopacova, Marcela

    2011-01-01

    To present our experience with the detection of bleeding in the small intestine by means of scintigraphy with in vivo-labelled red blood cells (RBCs) in the period of 1998-2009. A 12-year prospective study was accomplished with 40 patients (23 men, 17 women, aged 12-91, mean 56 years) who had lower gastrointestinal bleeding (obscure-overt bleeding) and underwent scintigraphy with in vivo-labelled RBCs by means of technetium 99m. The scintigraphy was usually performed after other diagnostic tests had failed to locate the bleeding. A total of 26 patients had a positive scintigraphy with in vivo-labelled RBCs and 14 patients had negative scintigraphy. The final diagnosis was confirmed in 20 of 26 patients with a positive scintigraphy by push enteroscopy (6/20), intraoperative enteroscopy (7/20), surgery (4/20), duodenoscopy (1/20), double-balloon enteroscopy (1/20) and X-ray angiography (1/20). The correct location of the bleeding site was identified by RBC scintigraphy in 15 of 20 (75%) patients with the confirmed source. The locations of the bleeding site identified by scintigraphy and enteroscopy (push, intraoperative) and surgical investigations were highly correlated in patients with a positive scintigraphy within the first 3 h. Eleven of the 20 correctly localized studies and none of the incorrectly localized studies were positive in the dynamic phase of imaging. In 5 patients (all erroneously localized), scintigraphy was positive only at a period longer than 18 h. RBC scintigraphy is an effective imaging modality in localizing lower gastrointestinal bleeding in patients for whom other diagnostic tests have failed to locate the bleeding. RBC scintigraphy can be successful in the detection of bleeding sites in the small intestine. Copyright © 2011 S. Karger AG, Basel.

  12. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    Science.gov (United States)

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most

  13. Meta-iodobenzylguanidine scintigraphy in neuroblastoma--a comparison with conventional X-ray and ultrasound

    International Nuclear Information System (INIS)

    Mueller-Gaertner, H.W.Er.; Erttmann, R.; Helmke, K.

    1986-01-01

    To evaluate the accuracy of meta-iodobenzylguanidine (MIBG) imaging in comparison with bone X-ray and ultrasound, 15 patients with histologically verified neuroblastoma were investigated using 123- or 131MIBG scintigraphy. 123MIBG and 131MIBG are used as the abbreviations for 123-iodine-labeled-MIBG and 131-iodine-labeled-MIBG, respectively. Either 7.4 MBq 131MIBG (n = 4) or 111-185 MBq 123MIBG (n = 11) was applied, and scans were performed 24 and 48 h PI. Anatomical orientation was provided in selected cases by single-photon emission CT or scintigraphy of other organs. X-ray procedures or ultrasound depicted 27 neuroblastoma manifestations (primary tumors and metastatic deposits); 24 of these (89%) were identified by MIBG scintigraphy. Of 42 primary neuroblastomas and metastatic deposits, 27 (64%) were detected by corresponding bone X-ray or ultrasound. The 15 neuroblastoma lesions depicted solely by MIBG scans were mainly (80%) situated in the skeletal system. Because of the pronounced physiological MIBG uptake by liver tissue, detection of intrahepatic or perihepatic tumor involvement is difficult. MIBG scintigraphy is a safe and noninvasive means of locating a wide range of neuroblastoma lesions. Its main diagnostic advantage in comparison with bone X-ray lies in the detection of bone marrow infiltration

  14. Multivariate normative comparison, a novel method for more reliably detecting cognitive impairment in HIV infection

    NARCIS (Netherlands)

    Su, Tanja; Schouten, Judith; Geurtsen, Gert J.; Wit, Ferdinand W.; Stolte, Ineke G.; Prins, Maria; Portegies, Peter; Caan, Matthan W. A.; Reiss, Peter; Majoie, Charles B.; Schmand, Ben A.

    2015-01-01

    The objective of this study is to assess whether multivariate normative comparison (MNC) improves detection of HIV-1-associated neurocognitive disorder (HAND) as compared with Frascati and Gisslén criteria. One-hundred and three HIV-1-infected men with suppressed viremia on combination

  15. Nonphysician Care Providers Can Help to Increase Detection of Cognitive Impairment and Encourage Diagnostic Evaluation for Dementia in Community and Residential Care Settings.

    Science.gov (United States)

    Maslow, Katie; Fortinsky, Richard H

    2018-01-18

    In the United States, at least half of older adults living with dementia do not have a diagnosis. Their cognitive impairment may not have been detected, and some older adults whose physician recommends that they obtain a diagnostic evaluation do not follow through on the recommendation. Initiatives to increase detection of cognitive impairment and diagnosis of dementia have focused primarily on physician practices and public information programs to raise awareness about the importance of detection and diagnosis. Nonphysician care providers who work with older adults in community and residential care settings, such as aging network agencies, public health agencies, senior housing, assisted living, and nursing homes, interact frequently with older adults who have cognitive impairment but have not had a diagnostic evaluation. These care providers may be aware of signs of cognitive impairment and older adults' concerns about their cognition that have not been expressed to their physician. Within their scope of practice and training, nonphysician care providers can help to increase detection of cognitive impairment and encourage older adults with cognitive impairment to obtain a diagnostic evaluation to determine the cause of the condition. This article provides seven practice recommendations intended to increase involvement of nonphysician care providers in detecting cognitive impairment and encouraging older adults to obtain a diagnostic evaluation. The Kickstart-Assess-Evaluate-Refer (KAER) framework for physician practice in detection and diagnosis of dementia is used to identify ways to coordinate physician and nonphysician efforts and thereby increase the proportion of older adults living with dementia who have a diagnosis. © The Author(s) 2018. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Can computed tomography volumetry of the renal cortex replace MAG3-scintigraphy in all patients for determining split renal function?

    Science.gov (United States)

    Houbois, Christian; Haneder, Stefan; Merkt, Martin; Morelli, John N; Schmidt, Matthias; Hellmich, Martin; Mueller, Roman-Ulrich; Wahba, Roger; Maintz, David; Puesken, Michael

    2018-06-01

    The current gold standard for determination of split renal function (SRF) is Tc-99m-mercapto-acetyltriglycin (MAG3) scintigraphy. Initial studies comparing MAG3-scintigraphy and CT-based renal cortex volumetry (RCV) for calculation of SRF have shown similar results in highly selected patient collectives with normal renal function (i.e. living kidney donors). This study aims to compare MAG3-scintigraphy and CT-RCV within a large unselected patient collective including patients with impaired renal function. For this assessment, 279 datasets (131 men, 148 women; mean age: 54.2 ± 12.9 years, range: 24-84 years) of patients who underwent MAG3-scintigraphy and contrast-enhanced abdominal CT within two weeks were retrospectively analyzed. Two independent readers assessed the CT-RCV in all CT datasets using a semi-automated volumetry tool. The MAG3-scintigraphy and CT-RCV methods were compared, stratified for the eGFR. Statistical analysis included descriptive statistics as well as inter- observer agreement. The absolute mean difference between the percentage contribution of the left and the right kidneys in total MAG3-clearance was 8.6%. Independent of eGFR, an overall sufficient agreement between both methods was established in all patients. A relatively small, tolerable systemic error resulted in an underestimation (max. 2%) of the left renal contribution to overall RCV. The results demonstrate that CT-RCV is a potential clinical replacement for MAG3-scintigraphy for calculation of SRF: CT-RCV demonstrates clinically tolerable differences with MAG3-scintigraphy, independent of patient eGFR. The relative complexity of the RCV method utilized is a potential limitation and may have contributed to the acceptable but only fair to moderate level of intra-reader reliability. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Fang Wei; Wang Feng; He Zuoxiang; Lu Jinguo; Lv Bing; He Jianguo; Liu Zhihong

    2008-01-01

    Objective: Chronic thromboembolic pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and multislice spiral CT pulmonary angiography (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or 'agreement' as in the original article) between the two techniques. Methods: Forty-nine in-patients with pulmonary hypertension without history of con- genital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q scintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q scintigraphy and CTPA were compared with the χ 2 test. Results: The sensitivity, specificity and accuracy of V/Q scintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9% (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49, Kappa=0.513), no statistically significant difference (χ 2 =0.75, P > 0.05 ) was found between V/Q scintigraphy and CTPA. Conclusion: Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH. (authors)

  18. Design process and preliminary psychometric study of a video game to detect cognitive impairment in senior adults

    Directory of Open Access Journals (Sweden)

    Sonia Valladares-Rodriguez

    2017-06-01

    Full Text Available Introduction Assessment of episodic memory has been traditionally used to evaluate potential cognitive impairments in senior adults. Typically, episodic memory evaluation is based on personal interviews and pen-and-paper tests. This article presents the design, development and a preliminary validation of a novel digital game to assess episodic memory intended to overcome the limitations of traditional methods, such as the cost of its administration, its intrusive character, the lack of early detection capabilities, the lack of ecological validity, the learning effect and the existence of confounding factors. Materials and Methods Our proposal is based on the gamification of the California Verbal Learning Test (CVLT and it has been designed to comply with the psychometric characteristics of reliability and validity. Two qualitative focus groups and a first pilot experiment were carried out to validate the proposal. Results A more ecological, non-intrusive and better administrable tool to perform cognitive assessment was developed. Initial evidence from the focus groups and pilot experiment confirmed the developed game’s usability and offered promising results insofar its psychometric validity is concerned. Moreover, the potential of this game for the cognitive classification of senior adults was confirmed, and administration time is dramatically reduced with respect to pen-and-paper tests. Limitations Additional research is needed to improve the resolution of the game for the identification of specific cognitive impairments, as well as to achieve a complete validation of the psychometric properties of the digital game. Conclusion Initial evidence show that serious games can be used as an instrument to assess the cognitive status of senior adults, and even to predict the onset of mild cognitive impairments or Alzheimer’s disease.

  19. Design process and preliminary psychometric study of a video game to detect cognitive impairment in senior adults.

    Science.gov (United States)

    Valladares-Rodriguez, Sonia; Perez-Rodriguez, Roberto; Facal, David; Fernandez-Iglesias, Manuel J; Anido-Rifon, Luis; Mouriño-Garcia, Marcos

    2017-01-01

    Assessment of episodic memory has been traditionally used to evaluate potential cognitive impairments in senior adults. Typically, episodic memory evaluation is based on personal interviews and pen-and-paper tests. This article presents the design, development and a preliminary validation of a novel digital game to assess episodic memory intended to overcome the limitations of traditional methods, such as the cost of its administration, its intrusive character, the lack of early detection capabilities, the lack of ecological validity, the learning effect and the existence of confounding factors. Our proposal is based on the gamification of the California Verbal Learning Test (CVLT) and it has been designed to comply with the psychometric characteristics of reliability and validity. Two qualitative focus groups and a first pilot experiment were carried out to validate the proposal. A more ecological, non-intrusive and better administrable tool to perform cognitive assessment was developed. Initial evidence from the focus groups and pilot experiment confirmed the developed game's usability and offered promising results insofar its psychometric validity is concerned. Moreover, the potential of this game for the cognitive classification of senior adults was confirmed, and administration time is dramatically reduced with respect to pen-and-paper tests. Additional research is needed to improve the resolution of the game for the identification of specific cognitive impairments, as well as to achieve a complete validation of the psychometric properties of the digital game. Initial evidence show that serious games can be used as an instrument to assess the cognitive status of senior adults, and even to predict the onset of mild cognitive impairments or Alzheimer's disease.

  20. Do We Need Exercise Tests to Detect Gas Exchange Impairment in Fibrotic Idiopathic Interstitial Pneumonias?

    Directory of Open Access Journals (Sweden)

    Benoit Wallaert

    2012-01-01

    Full Text Available In patients with fibrotic idiopathic interstitial pneumonia (f-IIP, the diffusing capacity for carbon monoxide (DLCO has been used to predict abnormal gas exchange in the lung. However, abnormal values for arterial blood gases during exercise are likely to be the most sensitive manifestations of lung disease. The aim of this study was to compare DLCO, resting PaO2, P(A-aO2 at cardiopulmonary exercise testing peak, and oxygen desaturation during a 6-min walk test (6MWT. Results were obtained in 121 patients with idiopathic pulmonary fibrosis (IPF, n=88 and fibrotic nonspecific interstitial pneumonias (NSIP, n=33. All but 3 patients (97.5% had low DLCO values (35 mmHg and 100 (83% demonstrated significant oxygen desaturation during 6MWT (>4%. Interestingly 27 patients had low DLCO and normal P(A-aO2, peak and/or no desaturation during the 6MWT. The 3 patients with normal DLCO also had normal PaO2, normal P(A-aO2, peak, and normal oxygen saturation during 6MWT. Our results demonstrate that in fibrotic IIP, DLCO better defines impairment of pulmonary gas exchange than resting PaO2, exercise P(A-aO2, peak, or 6MWT SpO2.

  1. Evaluation of diagnostic procedures such as plain-film scintigraphy and MR imaging for spinal metastases in relation to biological characteristics in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Hiroya; Nagao, Kazuharu; Nishimura, Reiki; Matsuda, Kazumasa; Baba, Kenichiro; Matsuoka, Yukio; Fukuda, Makoto; Higuchi, Akihiro; Saeki, Takahito [Kumamoto City Hospital (Japan)

    1995-09-01

    The relationship between spinal metastases diagnosed by plain-film, bone scintigraphy, and MR imaging and biological characteristics in 26 patients with breast cancer was investigated retrospectively. It was found that bone scintigraphy is useful for detecting metastases in case with slow-growing tumors determined by DNA polymerase {alpha} or with estrogen-receptor (ER) positivity. In contrast, cases with rapidly growing tumors showed false-negative plain-film or bone scintigraphy results, including cases with ER-negative tumors or DNA polymerase {alpha} of more than 20%. MR imaging was found to be highly sensitive in detecting spinal metastases even in aggressive cases. MR imaging was found to have greater reliability in detecting spinal metastases of breast cancer compared to bone scintigraphy. In conclusion, it may be important to consider the degree of malignancy of each case with spinal metastases of breast cancer in evaluating imaging diagnosis. (author).

  2. Evaluation of diagnostic procedures such as plain-film scintigraphy and MR imaging for spinal metastases in relation to biological characteristics in breast cancer

    International Nuclear Information System (INIS)

    Yamashita, Hiroya; Nagao, Kazuharu; Nishimura, Reiki; Matsuda, Kazumasa; Baba, Kenichiro; Matsuoka, Yukio; Fukuda, Makoto; Higuchi, Akihiro; Saeki, Takahito

    1995-01-01

    The relationship between spinal metastases diagnosed by plain-film, bone scintigraphy, and MR imaging and biological characteristics in 26 patients with breast cancer was investigated retrospectively. It was found that bone scintigraphy is useful for detecting metastases in case with slow-growing tumors determined by DNA polymerase α or with estrogen-receptor (ER) positivity. In contrast, cases with rapidly growing tumors showed false-negative plain-film or bone scintigraphy results, including cases with ER-negative tumors or DNA polymerase α of more than 20%. MR imaging was found to be highly sensitive in detecting spinal metastases even in aggressive cases. MR imaging was found to have greater reliability in detecting spinal metastases of breast cancer compared to bone scintigraphy. In conclusion, it may be important to consider the degree of malignancy of each case with spinal metastases of breast cancer in evaluating imaging diagnosis. (author)

  3. Prospective study of bone metastasis from prostate cancer: comparison between large field diffusion-weighted imaging and bone scintigraphy

    International Nuclear Information System (INIS)

    Wang Xiaoying; Zhang Chunyan; Jiang Xuexiang

    2009-01-01

    Objective: To evaluate the large field diffusion weighted imaging (DWI) (from head vertex to lower leg) in detection of bone metastases from prostate cancer. Methods: One hundred and sixty- six consecutive patients who were suspected of prostate cancer received pelvic MRI and large field diffusion weighted imaging examination. Forty-nine of them underwent bone scintigraphy within one month of the examination of large field DWI. The images were double-blindly evaluated without the knowledge of the pathology result. Conventional MR T 1 and fat saturation T 2 weighted images were taken as standard for the diagnosis of bone metastasis. The sensitivity, specificity, and area under curve between large field DWI and bone scintigraphy were compared with McNemar test. Five patients with bone metastases exceeding 10 per patient were excluded in the lesion-by-lesion analysis. Results: Ten of the 49 patients were diagnosed as bone metastases. The diagnosis of bone metastasis were made in 15 patients by large field DWI and in 17 patients by bone scintigraphy. With patient number as study units (n=49), the diagnostic sensitivity of bone metastases with large field DWI and bone metastases were both 100% (10/10), and specificity were 87.2% (34/39) vs. 82.1% (32/39), respectively. ROC study showed the area under curve (AUC) of large field DWI and bone scintigraphy were 0.936 vs. 0.910, respectively. Totally 68 abnormal foci were identified from large field DWI and/or bone scintigraphy in 44 patients (while 5 patients with bone metastases exceeding 10 foci per patient were excluded), 20 of them were diagnosed as foci of bone metastasis. The diagnosis of bone metastases was made in 23 foci by large field DWI and in 34 by bone scintigraphy. With lesion numbers as study units (n=68), the diagnostic sensitivity of large field DWI and bone scintigraphy were both 90.0% (18/20), and specificity were 89.6% (43/48) vs. 66.7% (32/48), respectively. ROC study showed the area under curve of

  4. Italian version of the Parkinson Neuropsychometric Dementia Assessment (PANDA): a useful instrument to detect cognitive impairments in Parkinson's Disease.

    Science.gov (United States)

    Pignatti, Riccardo; Bertella, Laura; Scarpina, Federica; Mauro, Alessandro; Portolani, Elisa; Calabrese, Pasquale

    2014-01-01

    Parkinson's disease (PD) is frequently characterized by cognitive and affective dysfunctions. The "Parkinson Neuropsychometric Dementia Assessment" (PANDA) is a screening tool designed for the early detection of mild cognitive impairment as well as dementia in PD. The PANDA is already validated in German and in French. The aim of the present work was to provide normative data for the Italian-speaking population, Swiss regions included; moreover, the effectiveness of the PANDA compared to the Mini Mental State Examination (MMSE) was tested. One-hundred and eleven PD patients with and without cognitive impairment and one-hundred and three matched healthy subjects participated at this study; all patients underwent an extensive neuropsychological evaluation. A PANDA total score of 13 appeared to be the most fitting cut-off with a sensitivity of 96.6% and a specificity of 82.2%; with the MMSE, the same value of sensitivity but with a specificity of 72,4% was reached only by adopting a cut-off of 28. Moreover, a PANDA range of 13-17 appeared to be suggestive for possible cognitive disturbance. The present work provides evidence for the effectiveness of the PANDA in evaluating cognitive deficits also in PD Italian-speaking patients, even when their pathological degree is still initial or very mild.

  5. Can Periodical Examinations of Employees Be Useful in Detection of Glycaemia Impairment and Improving Patients’ Adherence to Medical Recommendations?

    Directory of Open Access Journals (Sweden)

    Andrzej Marcinkiewicz

    2018-03-01

    Full Text Available Worldwide epidemiological data indicates insufficient diagnosis of diabetes as an increasing public health problem. In the search for solutions to this disadvantageous situation, occupational medicine health services seem to open up a unique opportunity to recognize some abnormalities in the early stages, especially among the asymptomatic working-age population. 316 workers underwent obligatory prophylactic examinations. In patients with twice assayed FGL ≥ 126 mg/dL (7.0 mmol/L an additional intervention was implemented, including further diagnostic processes and therapy in General Practice (GP, followed by examination by an occupational health specialist within 3 months. The diagnosis of previously unknown diabetes was established among 2.5% of examined workers. All patients referred to the GP due to detected glycaemia impairment visited their doctor and finished the diagnostic process, took up therapy constrained by the occupational health physician to show the effects of intervention within 3 months. Prophylactic medical check-ups allow improved compliance and medical surveillance over glycaemia impairment in patients with prediabetes states, unknown diabetes or uncontrolled clinical course of diabetes. Considering fasting glucose level during mandatory prophylactic examination helps effective prevention of diabetes and its complications and thus provides public health system benefits.

  6. Indications for scintigraphy with 67Ga

    International Nuclear Information System (INIS)

    Plechl, S.C.; Berges, G.; Blut, J.; Bohle, H.; Gessat, C.; Hethey, B.; Linneborn, G.; Ostermann, W.; Prack, G.; Scheitza, B.

    1976-01-01

    The validity and exactness of 67 Ga scintigraphy was tested in more than 70 patients by a comparison with clinical, radiological and histological findings as well as with scintigraphs obtained with other nuclides. It was found that 67 Ga scintigraphy is a good and often even a vital supplementation to the other methods. Its main field of application, according to the authors' obervations, is the differential diagnosis of three-dimensional changes in the thorax region, in particular the diagnosis of malignant tumours of the lungs in combination with X-ray examinations. Furthermore, 67 Ga may be of use in localization diagnoses of non-malignant changes, e.g. abscesses. 67 Ga scintigraphy, which is non-hazardous and does not involve discomfort to the patients, appears to be particularly useful for course control after surgical treatment of breast cancer and for early diagnoses of metastases, provided that examination starts early enough and is repeated at regular intervals, not only in the soft parts but also in the skeleton. The question whether 67 Ga scintigraphy may be a substitute for scintigraphy with other nuclides in these fields still remains to be solved. (orig.) [de

  7. Recent advances in gastric emptying scintigraphy

    International Nuclear Information System (INIS)

    Urbain, J.L.C.; Mayeur, S.M.

    1996-01-01

    Gastric emptying scintigraphy was introduced more than 25 years ago by Grittith and still remains the gold standard to assess gastric emptying. Test meals, radiopharmaceuticals and acquisition procedures have been refined and optimized over the years and the test procedure is now pretty well standardized. However, in its most common use, gastric emptying scintigraphy provides little information on gastric physiology. Over the last decade, modelling of the liquid and solid emptying curves have brought some insight in the complex gastric physiology. Compartmental analysis of the stomach has also provided information on the pathophysiological mechanisms of delayed gastric emptying. Over the past 5 years, the most dramatic development in gastric emptying scintigraphy has been the introduction of Digital Antral Scintigraphy (DAS). Digital Antral scintigraphy basically consists in dynamically imaging of the stomach and the use of a refined Fourier transform processing method. This new procedure allows for the visualization of antral contractions and, alike manometry, permits quantitative characterization on the frequency and amplitude of these contractions. Overall, this new procedure provides a unique, non invasive tool to characterize gastric motility, to define the pathophysiologic mechanisms of gastric motor disorders and to evaluate the effect of new gastro-kinetic compounds. (authors). 241 refs., 5 figs

  8. Indications for scintigraphy with /sup 67/Ga

    Energy Technology Data Exchange (ETDEWEB)

    Plechl, S C; Berges, G; Blut, J; Bohle, H; Gessat, C; Hethey, B; Linneborn, G; Ostermann, W; Prack, G; Scheitza, B [Berufsgenossenschaftliche Krankenanstalten Bergmannsheil, Bochum (Germany, F.R.)

    1976-06-01

    The validity and exactness of /sup 67/Ga scintigraphy was tested in more than 70 patients by a comparison with clinical, radiological and histological findings as well as with scintigraphs obtained with other nuclides. It was found that /sup 67/Ga scintigraphy is a good and often even a vital supplementation to the other methods. Its main field of application, according to the authors' obervations, is the differential diagnosis of three-dimensional changes in the thorax region, in particular the diagnosis of malignant tumours of the lungs in combination with X-ray examinations. Furthermore, /sup 67/Ga may be of use in localization diagnoses of non-malignant changes, e.g. abscesses. /sup 67/Ga scintigraphy, which is non-hazardous and does not involve discomfort to the patients, appears to be particularly useful for course control after surgical treatment of breast cancer and for early diagnoses of metastases, provided that examination starts early enough and is repeated at regular intervals, not only in the soft parts but also in the skeleton. The question whether /sup 67/Ga scintigraphy may be a substitute for scintigraphy with other nuclides in these fields still remains to be solved.

  9. {sup 123}I-meta-iodo-benzyl-guanidine myocardial scintigraphy and congestive heart failure: current data and perspective; Scintigraphie myocardique a la {sup 123}I-meta-iodobenzylguanidine et insuffisance cardiaque congestibe: donnees actuelles et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, D.; Darlas, Y.; Quennelle, F.; Bouvard, G.; Scanu, P.; Grollier, G.; Potier, J.C.; Babatasi, G. [Centre Hospitalier Universitaire, 14 - Caen (France); Belin, A. [Hopital de Trouville, Trouville (France)

    1997-12-31

    Congestive heart failure is often associated with an impairment of the sympathetic nervous system, i.e., global hyperactivity and regional impairment of the adrenergic system. Cardiac {sup 123}I-MIBG scintigraphy is a radionuclide technique which can explore the presynaptic adrenergic function. Myocardial MIBG fixation is decreased in congestive heart failure, reflecting a reduction of norepinephrine uptake by the myocardial presynaptic nerve endings. The impairment of presynaptic function occurs early in the disease and is actually involved in the pathogenesis of cardiac failure. Cardiac MIBG scintigraphy is a useful tool to explore the myocardial adrenergic stores in patients with congestive heart failure. It could be proposed in patients with severe ventricular dysfunction in order to assist physicians in setting-up the timing of heart transplantation. (authors). 52 refs.

  10. A Pilot Study of Pedestrians with Visual Impairments Detecting Traffic Gaps and Surges Containing Hybrid Vehicles.

    Science.gov (United States)

    Emerson, Robert Wall; Naghshineh, Koorosh; Hapeman, Julie; Wiener, William

    2011-03-01

    The increasing number of hybrid and quiet internal combustion engine vehicles may impact the travel abilities of pedestrians who are blind. Pedestrians who rely on auditory cues for structuring their travel may face challenges in making crossing decisions in the presence of quiet vehicles. This article describes results of initial studies looking at the crossing decisions of pedestrians who are blind at an uncontrolled crossing (no traffic control) and a light controlled intersection. The presence of hybrid vehicles was a factor in each situation. At the uncontrolled crossing, Toyota hybrids were most difficult to detect but crossing decisions were made more often in small gaps ended by a Honda hybrid. These effects were seen only at speed under 20 mph. At the light controlled intersection, parallel surges of traffic were most difficult to detect when made up only of a Ford Escape hybrid. Results suggest that more controlled studies of vehicle characteristics impacting crossing decisions of pedestrians who are blind are warranted.

  11. Gall blandder kinetics in diabetics. A hepatobiliary scintigraphy overview

    International Nuclear Information System (INIS)

    Shelley, S.; Indirani, M.; Gokhale, S.; Anirudhan, N.

    2004-01-01

    Introduction: Hepatobiliary scintigraphy is underutilized in the evaluation of Gall Bladder(GB) function in diabetics when compared to various other imaging modalities that are currently available.It establishes the function of GB in Diabetes mellitus noninvasively, with a quantified ejection fraction thereby helping to resolve the problem of diabetic cholecystopathy, in the evaluation of visceral neuropathy. Aim: To study Gall Bladder kinetics and emptying in diabetic patients. Materials and methods: One forty eight patients of both sexes in the age group of 30 to 70 were included in the study between 1997 to 1999 in our institution.A 90 minute dynamic post mebrofenin study was acquired. A fatty meal of 600 kcal was given to these patients once the Gall Bladder was visualized.Time activity curves were generated and the Gall Bladder contraction in these patients was evaluated.Patients were classified into 3 groups-Group 1 consists of established Diabetic patients. Group 2 consists of patients with impaired glucose tolerance. Group 3 consists of controls. Observation and result: In Group 1 (n=47) ,28 patients (60%) showed reduced ejection fraction and the mean EF% was 44.12 +/- 16.6. In Group 2 (n=48), 18 patients (38%) showed slightly reduced ejection fraction and the mean EF % was 51.56 +/- 15.67. In Group 3(n=53), 7 patients (13%) showed reduced ejection fraction and the meanEF % was 69.77 +/- 13.59. Test of significance was done using 'Z' test also called normal test in large samples. This study has shown that the average Ejection Fraction (in%) is maximum in normal group and least in diabetic group. Conclusion: Hepatobiliary scintigraphy is helpful in early identification of autonomic dysfunction of Gall Bladder in diabetic patients and in patients with impaired glucose tolerance. (authors)

  12. Detecting altered connectivity patterns in HIV associated neurocognitive impairment using mutual connectivity analysis

    Science.gov (United States)

    Abidin, Anas Zainul; D'Souza, Adora M.; Nagarajan, Mahesh B.; Wismüller, Axel

    2016-03-01

    The use of functional Magnetic Resonance Imaging (fMRI) has provided interesting insights into our understanding of the brain. In clinical setups these scans have been used to detect and study changes in the brain network properties in various neurological disorders. A large percentage of subjects infected with HIV present cognitive deficits, which are known as HIV associated neurocognitive disorder (HAND). In this study we propose to use our novel technique named Mutual Connectivity Analysis (MCA) to detect differences in brain networks in subjects with and without HIV infection. Resting state functional MRI scans acquired from 10 subjects (5 HIV+ and 5 HIV-) were subject to standard preprocessing routines. Subsequently, the average time-series for each brain region of the Automated Anatomic Labeling (AAL) atlas are extracted and used with the MCA framework to obtain a graph characterizing the interactions between them. The network graphs obtained for different subjects are then compared using Network-Based Statistics (NBS), which is an approach to detect differences between graphs edges while controlling for the family-wise error rate when mass univariate testing is performed. Applying this approach on the graphs obtained yields a single network encompassing 42 nodes and 65 edges, which is significantly different between the two subject groups. Specifically connections to the regions in and around the basal ganglia are significantly decreased. Also some nodes corresponding to the posterior cingulate cortex are affected. These results are inline with our current understanding of pathophysiological mechanisms of HIV associated neurocognitive disease (HAND) and other HIV based fMRI connectivity studies. Hence, we illustrate the applicability of our novel approach with network-based statistics in a clinical case-control study to detect differences connectivity patterns.

  13. Rater agreement in lung scintigraphy

    International Nuclear Information System (INIS)

    Christiansen, F.; Andersson, T.; Rydman, H.; Qvarner, N.; Maare, K.

    1996-01-01

    Purpose: The PIOPED criteria in their original and revised forms are today's standards in the interpretation of ventilation-perfusion scintigraphy. When the PIOPED criteria are used by experienced raters with training in consensus interpretation, the agreement rates have been demonstrated to be excellent. Our purpose was to investigate the rates of agreement between 2 experienced raters from different hospitals who had no training in consensus interpretation. Material and Methods: The 2 raters investigated a population of 195 patients. This group included 72 patients from a previous study who had an intermediate probability of pulmonary embolism and who had also been examined by pulmonary angiography. Results: The results demonstrated moderate agreement rates with a kappa value of 0.54 (0.45-0.63 in a 95% confidence interval), which is similar to the kappa value of the PIOPED study but significantly lower than the kappa values of agreement rates among consensus-trained raters. There was a low consistency in the intermediate probability category, with a proportional agreement rate of 0.39 between the experienced raters. Conclusion: The moderate agreement rates between raters from different hospitals make it difficult to compare study populations of a certain scintigraphic category in different hospitals. Further investigations are mandatory for accurate diagnosis when the scintigrams are in the category of intermediate probability of pulmonary embolism. (orig.)

  14. Gamma-scintigraphy; La gammascintigraphie

    Energy Technology Data Exchange (ETDEWEB)

    Desgrez, H.A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-06-15

    Gamma-scintigraphy is a medical technique making it possible to fix the image of certain organs after the concentration in these of emitting radioactive products. It is already widely used in the case of the thyroid gland with iodine-132 by applying the isotope iodine 131. The study of the liver and gall bladder is carried out using colloidal gold 198 and Bengal pink marked with iodine 131. Serum albumin marked with iodine 131 makes it possible to study rachidian blockages. Other applications can already be foreseen in this direction. (author) [French] La gammascintigraphie est une technique medicale permettant de faire l'image de certains organes apres concentration dans ceux-ci de produits radioactifs emetteurs. Son utilisation deja repandue en ce qui concerne la thyroidine et l'iode-131 est possible avec l'iode-132 pour cette meme glande. Avec l'or colloidal 198 et le rose bengale marque a l'iode-131, on pratique des etudes du foie et de la vesicule biliaire. La serumalbumine marquee a l'iode-131 permet d'etudier les blocages rachidiens. D'autres possibilites sont des maintenant envisageables dans cette direction. (auteur)

  15. Gamma-scintigraphy; La gammascintigraphie

    Energy Technology Data Exchange (ETDEWEB)

    Desgrez, H A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-06-15

    Gamma-scintigraphy is a medical technique making it possible to fix the image of certain organs after the concentration in these of emitting radioactive products. It is already widely used in the case of the thyroid gland with iodine-132 by applying the isotope iodine 131. The study of the liver and gall bladder is carried out using colloidal gold 198 and Bengal pink marked with iodine 131. Serum albumin marked with iodine 131 makes it possible to study rachidian blockages. Other applications can already be foreseen in this direction. (author) [French] La gammascintigraphie est une technique medicale permettant de faire l'image de certains organes apres concentration dans ceux-ci de produits radioactifs emetteurs. Son utilisation deja repandue en ce qui concerne la thyroidine et l'iode-131 est possible avec l'iode-132 pour cette meme glande. Avec l'or colloidal 198 et le rose bengale marque a l'iode-131, on pratique des etudes du foie et de la vesicule biliaire. La serumalbumine marquee a l'iode-131 permet d'etudier les blocages rachidiens. D'autres possibilites sont des maintenant envisageables dans cette direction. (auteur)

  16. Retrospective Analysis of Indication of Bone Scintigraphy Performed in Our Clinic

    Directory of Open Access Journals (Sweden)

    Fusun Aydogan

    2014-03-01

    Full Text Available Aim: Bone scintigraphy is one of the commonly used radionuclide imaging and it is successfully used in the diagnosis and follow-up of many diseases. The aim of this study is to determine the indications and filming protocols of bone scintigraphy which was performed in our clinic. Material and Method: Two hundred and fifty two patients (132 male, 120 female who was performed bone scintigprapy in our clinic between December 2011 and June 2013 included the study. Mean age was 50.1±20.2 years. Scintigraphic protocols were made in two ways as late static whole body imaging and three-phase bone scintigraphy according to the type of the diseases. Indications of scintigraphies and scintigraphic protocols were detected. Results: Bone scintigraphy was performed for diagnosis and monitoring of metastatic bone disease to 102 patients (40,5 %, for orthopedic applications to 57 patients (22,6 %, for diagnosis and monitoring of primary bone tumors to 29 patients (11,5 %, for diagnosis of osteomyelitis to 17 patients (6,7 %, for differential diagnosis of infection and loosening of the prosthesis to 12 patients (4,8 %, investigate the viability of the graft in 14 patients (4,6 %, for rheumatologic diseases to 9 patients (3,6 %, for investigate the pathological vertebral fractures and osteoporosis to 4 patients (1,6 %, for diagnosis the metabolic bone disease to 2 patients (0,8 %, for diagnosis of otitis externa to 5 patients (1,98 % and for for suspicion of malignancy to 1 patient (0,4 %. Late static whole body imaging protocol was applied to 136 patients (54 % and three-phase imaging protocol was applied to 116 patients (46 %. Discussion: The most common use of bone scintigraphy is the diagnosis and follow-up of metastatic bone disease. It is followed by reasons such as orthopedic applications, monitoring and diagnosis of primary bone tumors and diagnosis of osteomyelitis.

  17. Correlation Between Bone Scintigraphy and Tumor Markers in Patients with Breast Carcinoma

    Directory of Open Access Journals (Sweden)

    Amela Begić

    2006-02-01

    Full Text Available A characteristic feature of many cancer types is their ability to metastasise to the skeleton. Bone is the most common site of metastatic invasion, after hematogenous spreading of breast cancer. Early detection of bone metastases is mandatory in the evaluation and management of these patients. Bone scintigraphy is commonly performed in detection and evaluation bone metastases. Tumor markers are present in healthy individuals as well as in patients with malignant diseases but in different concentration. Aim of study was to correlate serum levels of tumor marker Ca (15-3, CEA and presence of bone metastases detected by bone scintigraphy. Study included 25 patients with breast cancer, previously surgically treated. All patients underwent whole body scintigraphy. Ca (15-3 and CEA was measured by radioimmunoassay. Presence, number of bone metastases were correlated with Ca (15-3 and CEA levels. Median age of patients included in study was 50 varying from 30 to 67. Bone scintigraphy revealed bone metastases in 16 (64% patients. A weak correlation was found between number of metastases and level of Ca (15-3 (r=0.139, p=0.254. Significant differences in Ca (15-3 level was found in patient with metastases compared to patients without metastases (chi square 0, p=1.0. Good correlation was found between number of metastases and serum level of CEA. Correlation between level of two tumor markers Ca (15-3 and CEA was a weak (r = 0.096 , p=0.323. Bone scintigraphy is a sensitive diagnostic toll for detecting breast cancer metastases to bone. Serum levels of tumor markes in isolation can not give complete accuracy about bone metastases.

  18. 123I-meta-iodo-benzyl-guanidine myocardial scintigraphy and congestive heart failure: current data and perspective

    International Nuclear Information System (INIS)

    Agostini, D.; Darlas, Y.; Quennelle, F.; Bouvard, G.; Scanu, P.; Grollier, G.; Potier, J.C.; Babatasi, G.; Belin, A.

    1997-01-01

    Congestive heart failure is often associated with an impairment of the sympathetic nervous system, i.e., global hyperactivity and regional impairment of the adrenergic system. Cardiac 123 I-MIBG scintigraphy is a radionuclide technique which can explore the presynaptic adrenergic function. Myocardial MIBG fixation is decreased in congestive heart failure, reflecting a reduction of norepinephrine uptake by the myocardial presynaptic nerve endings. The impairment of presynaptic function occurs early in the disease and is actually involved in the pathogenesis of cardiac failure. Cardiac MIBG scintigraphy is a useful tool to explore the myocardial adrenergic stores in patients with congestive heart failure. It could be proposed in patients with severe ventricular dysfunction in order to assist physicians in setting-up the timing of heart transplantation. (authors)

  19. Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile

    International Nuclear Information System (INIS)

    Nemec, J.; Nyvltova, O.; Blazek, T.; Vlcek, P.; Racek, P.; Novak, Z.; Preiningerova, M.; Hubackova, M.; Krizova, M.; Zimak, J.; Bilek, R.

    1996-01-01

    The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30 min following i.v. administration of 500 MBq of 99m Tc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99m Tc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions. (orig.)

  20. Paradoxical hypotension during dobutamine infusion for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Erguen, E.L.; Caner, B.; Atalar, E.; Karanfil, A.; Tokgoezoglu, L.

    1998-01-01

    Dobutamine as a predominant beta-1 agonist increases heart rate and myocardial contractility and at sufficient high doses, it also increases systolic blood pressure. This study was undertaken to describe instances of paradoxical hypotension during dobutamine infusion for Tl-201 myocardial perfusion SPECT study and the relationship between scintigraphic findings and hypotension occurred during dobutamine infusion. Methods: In 201 consecutive patients unable to perform adequate exercise, dobutamine Tl-201 myocardial SPECT was performed. Dobutamine was infused starting from 10 μg/kg/min increasing to 40 μ/kg/min. Paradoxical hypotension was defined as a decrease in systolic blood pressure ≥ 20 mmHg compared with baseline study. Paradoxical hypotension was observed in 40 patients (Group A) out of 201 (19.9%) while no significant change in systolic blood pressure was detected in the remaining 161 patients (Group B). Mean maximum fall in systolic blood pressure was 39±18 mmHg (range: 20-90). In 33 of 40 patients (83%) with paradoxical hypotension, scintigraphy was normal compared to 131 (81%) of the remaining 161 patients. In patients of Group A, angiography, echocardiography and tilt table tests were performed in 13, 11 and 6 patients respectively. Nine of 13 angiographic evaluations (69%), 10 of 11 echocardiographic evaluations (91%), all of the tilt table tests were normal. Additionally, all of the patients of Group A were clinically followed up at least 6 months after the myocardial perfusion scintigraphy. None of the patients had a cardiac event except one patient during the follow-up period. Conclusion: Paradoxical hypotension during dobutamine infusion for myocardial scintigraphy is not an uncommon finding and up to 19.9% patients may develop such hypotension. To maximize test safety, precautions should be taken during dobutamine myocardial stress test, since remarkable decrease in systolic blood pressure may occur. Unlike hypotension occurring with exercise

  1. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Wook; Lee, Heon Young [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    1995-06-15

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  2. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Lee, Heon Young

    1995-01-01

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  3. Type 2 diabetes impairs odour detection, olfactory memory and olfactory neuroplasticity; effects partly reversed by the DPP-4 inhibitor Linagliptin.

    Science.gov (United States)

    Lietzau, Grazyna; Davidsson, William; Östenson, Claes-Göran; Chiazza, Fausto; Nathanson, David; Pintana, Hiranya; Skogsberg, Josefin; Klein, Thomas; Nyström, Thomas; Darsalia, Vladimer; Patrone, Cesare

    2018-02-23

    Recent data suggest that olfactory deficits could represent an early marker and a pathogenic mechanism at the basis of cognitive decline in type 2 diabetes (T2D). However, research is needed to further characterize olfactory deficits in diabetes, their relation to cognitive decline and underlying mechanisms.The aim of this study was to determine whether T2D impairs odour detection, olfactory memory as well as neuroplasticity in two major brain areas responsible for olfaction and odour coding: the main olfactory bulb (MOB) and the piriform cortex (PC), respectively. Dipeptidyl peptidase-4 inhibitors (DPP-4i) are clinically used T2D drugs exerting also beneficial effects in the brain. Therefore, we aimed to determine whether DPP-4i could reverse the potentially detrimental effects of T2D on the olfactory system.Non-diabetic Wistar and T2D Goto-Kakizaki rats, untreated or treated for 16 weeks with the DPP-4i linagliptin, were employed. Odour detection and olfactory memory were assessed by using the block, the habituation-dishabituation and the buried pellet tests. We assessed neuroplasticity in the MOB by quantifying adult neurogenesis and GABAergic inhibitory interneurons positive for calbindin, parvalbumin and carletinin. In the PC, neuroplasticity was assessed by quantifying the same populations of interneurons and a newly identified form of olfactory neuroplasticity mediated by post-mitotic doublecortin (DCX) + immature neurons.We show that T2D dramatically reduced odour detection and olfactory memory. Moreover, T2D decreased neurogenesis in the MOB, impaired the differentiation of DCX+ immature neurons in the PC and altered GABAergic interneurons protein expression in both olfactory areas. DPP-4i did not improve odour detection and olfactory memory. However, it normalized T2D-induced effects on neuroplasticity.The results provide new knowledge on the detrimental effects of T2D on the olfactory system. This knowledge could constitute essentials for

  4. Bone scintigraphy in systemic and metabolic diseases

    International Nuclear Information System (INIS)

    Engels, H.J.; Schmidt, H.A.E.

    1984-01-01

    Bone scintigraphy is a very sensitive method to identify pathological processes affecting the bone. Its specificity is, however, considerably lower than its sensitivity, particularly in systemic diseases. We therefore investigated the possibilities of differential diagnosis based on typical sites or patterns of distribution. The Paget syndrome with characteristic manifestation in the pelvic region, including crutch-shaped accumulation in the proximal femur, may be diagnosed by scintigraphy alone. If these typical sites are absent, however, differential diagnosis is difficult. Differential diagnosis for multiple myeloma, fibrous dysplasia, enchondromatosis, hyperparathyroidism, osteopathies, osteomalacia, inflammatory rheumatic diseases is also required and should be based on further examinations, taking into consideration the history, clinical signs and course. In this connexion scintigraphy is relevant both for early assessment and documentation of the spread of pathological processes and for the follow-up. (orig.) [de

  5. Perfusion scintigraphy in acute myocardial infarction

    International Nuclear Information System (INIS)

    Schricke, U.; Schwaiger, M.; Kastrati, A.; Schoemig, A.

    1999-01-01

    The Tc-99m sestamibi perfusion SPECT scintigraphy in acute myocardial infarction is a feasible method to assess the size of area at risk and the residual blood flow to this area as the most important determinants of final infarct size without any delay in treatment. In combination with a follow-up study final infarct size as well as myocardial salvage can be quantified. Clinical indications for the use of Tc-99m sestamibi scintigraphy are the noninvasive identification of arterial occlusion in patients suspected to acute myocardial infarction without electrocardiographic ST-elevation and the assessment of reperfusion success. In clinical trials Tc-99m sestamibi scintigraphy has proven to be a useful method to assess the impact of varying reperfusion therapies. The present review article discusses the indication, the study protocol, the interpretation of results and the clinical and scientifically importance of this method. (orig.) [de

  6. DEEP-SEE: Joint Object Detection, Tracking and Recognition with Application to Visually Impaired Navigational Assistance

    Directory of Open Access Journals (Sweden)

    Ruxandra Tapu

    2017-10-01

    Full Text Available In this paper, we introduce the so-called DEEP-SEE framework that jointly exploits computer vision algorithms and deep convolutional neural networks (CNNs to detect, track and recognize in real time objects encountered during navigation in the outdoor environment. A first feature concerns an object detection technique designed to localize both static and dynamic objects without any a priori knowledge about their position, type or shape. The methodological core of the proposed approach relies on a novel object tracking method based on two convolutional neural networks trained offline. The key principle consists of alternating between tracking using motion information and predicting the object location in time based on visual similarity. The validation of the tracking technique is performed on standard benchmark VOT datasets, and shows that the proposed approach returns state-of-the-art results while minimizing the computational complexity. Then, the DEEP-SEE framework is integrated into a novel assistive device, designed to improve cognition of VI people and to increase their safety when navigating in crowded urban scenes. The validation of our assistive device is performed on a video dataset with 30 elements acquired with the help of VI users. The proposed system shows high accuracy (>90% and robustness (>90% scores regardless on the scene dynamics.

  7. A Pilot Study of Pedestrians with Visual Impairments Detecting Traffic Gaps and Surges Containing Hybrid Vehicles

    Science.gov (United States)

    Emerson, Robert Wall; Naghshineh, Koorosh; Hapeman, Julie; Wiener, William

    2010-01-01

    The increasing number of hybrid and quiet internal combustion engine vehicles may impact the travel abilities of pedestrians who are blind. Pedestrians who rely on auditory cues for structuring their travel may face challenges in making crossing decisions in the presence of quiet vehicles. This article describes results of initial studies looking at the crossing decisions of pedestrians who are blind at an uncontrolled crossing (no traffic control) and a light controlled intersection. The presence of hybrid vehicles was a factor in each situation. At the uncontrolled crossing, Toyota hybrids were most difficult to detect but crossing decisions were made more often in small gaps ended by a Honda hybrid. These effects were seen only at speed under 20 mph. At the light controlled intersection, parallel surges of traffic were most difficult to detect when made up only of a Ford Escape hybrid. Results suggest that more controlled studies of vehicle characteristics impacting crossing decisions of pedestrians who are blind are warranted. PMID:21379367

  8. Diagnostic value of technetium pyrophosphate bone scintigraphy. Study of 277 patients

    International Nuclear Information System (INIS)

    Sainte-Croix, Annick.

    1975-01-01

    277 bone scintigraphs were carried out with 99m technetium pyrophosphate and an attempt was made, on the basis of this experience, to define the advantages and limits of the technique. 99m technetium pyrophosphate seems to be the isotope most suitable for bone scintigraphy. The scintillation camera bone scintigraphic examination is simple, allowing the whole skeleton to be explored in a relatively short time, and above all harmless since the total irradiation to which the organism is exposed throughout is no more than 0.07 rad. The broadest field of application of bone scintigraphy appears to be cancer: in 45 cases out of 66 it revealed bone metastases invisible radiologically and in 28 cases out of 90 the number of metastases observed was greater than that shown by X-rays. In 11 cases however radiologically visible bone metastases were not detected by scintigraphy. In spite of this reservation we consider bone scintigraphy to be a valuable technique, more sensitive than X-ray examinations in the detection of bone metastases of cancers [fr

  9. Bone scintigraphy screening for osteonecrosis of the shoulder in patients with non-traumatic osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Sakai, Takashi; Sugano, Nobuhiko; Nishii, Takashi; Miki, Hidenobu; Yoshikawa, Hideki; Ohzono, Kenji

    2002-01-01

    In patients with non-traumatic osteonecrosis of the femoral head (ONFH), the shoulder is one of the major affected sites secondary to the proximal and distal femur in cases of multiple osteonecrosis. The present study attempted to investigate whether technetium bone scintigraphy is useful for screening of non-traumatic osteonecrosis of the shoulder (ONS).Design and patients. A total of 170 shoulder joints in 85 patients with ONFH were evaluated by bone scintigraphy and the findings compared with those of magnetic resonance imaging (MRI). The MR diagnosis was used as the gold standard.Results. Based on the diagnosis by MRI, ONS was detected in 43 shoulders of 27 patients (25%). All necrotic lesions were located in the humeral head. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of bone scintigraphy for ONS detection were 65%, 81%, 77%, 54% and 87%, respectively. When the necrotic angle of the lesions on the mid-coronal MRI was more than 40 , the sensitivity of bone scintigraphy for ONS detection increased to 88% (21/24 shoulders).Conclusion. Bone scintigraphy may be useful for demonstrating medium or large ONS lesions on screening of patients with ONFH. (orig.)

  10. Bone-scintigraphy in painful bipartite patella

    International Nuclear Information System (INIS)

    Iossifidis, A.; Brueton, R.N.; Nunan, T.O.

    1995-01-01

    Although, the use of technetium scintigraphy in the assessment of anterior knee pain has been described, no reference has been made to the scintigraphic appearances of painful bipartite patella. We report the scintigraphic-appearances of painful bipartite patella in 25-year-old man a 2 1/2 years history of unexplained patellar pain. Painful bipartite patella is a rare cause of chronic post-traumatic patellar pain. Bone scintigraphy, by demonstrating increased uptake by the painful accessory bipartite fragment, appears to be an imaging method of choice in the diagnosis of this condition. (orig./MG)

  11. Quantitative whole body scintigraphy - a simplified approach

    International Nuclear Information System (INIS)

    Marienhagen, J.; Maenner, P.; Bock, E.; Schoenberger, J.; Eilles, C.

    1996-01-01

    In this paper we present investigations on a simplified method of quantitative whole body scintigraphy by using a dual head LFOV-gamma camera and a calibration algorithm without the need of additional attenuation or scatter correction. Validation of this approach to the anthropomorphic phantom as well as in patient studies showed a high accuracy concerning quantification of whole body activity (102.8% and 97.72%, resp.), by contrast organ activities were recovered with an error range up to 12%. The described method can be easily performed using commercially available software packages and is recommendable especially for quantitative whole body scintigraphy in a clinical setting. (orig.) [de

  12. Scintigraphy and ultrasonography of various thyroid diseases

    International Nuclear Information System (INIS)

    Ban, Yoshio; Nagakura, Hozumi; Kawauchi, Akihiro; Fukunari, Nobuhiro; Itoh, Kunihiko; Higashi, Tomomitsu.

    1987-01-01

    We reported the usefulness of scintigraphy and ultrasonography of various thyroid diseases. The scintigraphy were useful information in the determination of functioning adenoma, location of ectopic thyroid glands and appearance of lang and bone metastasis of thyroid carcinoma. As ultrasonography were able to be observation of internal structure of thyroid gland, that maight be used to determined associated nodular lesions in diffuse goiter and differentiation between benign and malignant tumor in nodular goiter. In observation of calcifications of goiter, soft X rays apparatus were usefull tool. US, as initial diagnostic test before scintiscanning, provided useful information and minimized radiation exposure. (author)

  13. Radioaerosol lung scintigraphy in idiopathic scolios

    International Nuclear Information System (INIS)

    Maini, C.L.; Giordano, A.; Santucci, B.; Aulisa, L.; Pistelli, R.; Fuso, L.

    1988-01-01

    The study of respiratory fuctions is of key importance for the clinical evaluation of patients with idiopathic scoliosis. Such study has been traditionally based on classical pulmonary function tests and arterial hemogasanalysis. However, neither procedure gives any information on the topographical distribution of abnormalities, and both might be suboptimal as far as sensitivity is concerned. The preliminary results obtained with radioaerosol lung scintigraphy in 11 patients with scoliosis are here presented. They lead to the conclusion that radioaerosol lung scintigraphy, besides being an useful adjunct to more traditional diagnostic procedures, can yield unique information on the localization of convective ventilation derangements induced by the dynamic abnormalities of the rib cage

  14. Indium 111 leucocyte scintigraphy in abdominal sepsis

    International Nuclear Information System (INIS)

    Baba, A.A.; McKillop, J.H.; Gray, H.W.; Cuthbert, G.F.; Neilson, W.; Anderson, J.R.

    1990-01-01

    We have studied the clinical utility of indium 111 autologous leucocyte scintigraphy retrospectively in 45 patients presenting with suspected intra-abdominal sepsis. The sensitivity was 95% (21/22) and the specificity was 91% (21/23). Some 34 of the studies (17 positive and 17 negative) were considered helpful in furthering patient management (76%) and 8, unhelpful (18%). In 3, the study results were misleading and led to inappropriate treatment. Indium 111 scintigraphy, whether positive or negative, provides information in patients with suspected intra-abdominal sepsis upon which therapeutic decisions can be based. (orig.)

  15. Guidelines for radioiodinated MIBG scintigraphy in children.

    Science.gov (United States)

    Olivier, Pierre; Colarinha, Paula; Fettich, Jure; Fischer, Sibylle; Frökier, Jörgen; Giammarile, Francesco; Gordon, Isky; Hahn, Klaus; Kabasakal, Levent; Mann, Mike; Mitjavila, Mercedes; Piepsz, Amy; Porn, Ute; Sixt, Rune; van Velzen, Jeannette

    2003-05-01

    These guidelines on the use of radioiodinated (99m)Tc-MIBG scintigraphy in children, which summarise the views of the Paediatric Committee of the European Association of Nuclear Medicine, provide a framework which may prove helpful to nuclear medicine teams in daily practice. They have been influenced by the conclusions of the "Consensus Guidelines for MIBG Scintigraphy" (Paris, November 6, 1997) of the European Neuroblastoma Group and by those of the Oncological Committee of the French Society of Nuclear Medicine. The guidelines should be taken in the context of "good practice" and any local/national rules which apply to nuclear medicine examinations.

  16. Gallium-67 scintigraphy in borderline lepromatous leprosy

    International Nuclear Information System (INIS)

    Mouratidis, B.; Lomas, F.E.

    1993-01-01

    A middle aged woman with a pyrexia of unknown origin was shown to have borderline lepromatous leprosy. Early gallium-67 scintigraphy demonstrated increased uptake in the subcutaneous tissues of the face and thighs. As a result of these findings skin biopsy was obtained from the right thigh which gave a diagnosis of borderline lepromatous leprosy. The authors have been unable to find other reports of gallium-67 scintigraphy in leprosy but the pattern of gallium-67 distribution should suggest the diagnosis. 5 refs., 1 fig

  17. Lightening the load: perceptual load impairs visual detection in typical adults but not in autism.

    Science.gov (United States)

    Remington, Anna M; Swettenham, John G; Lavie, Nilli

    2012-05-01

    Autism spectrum disorder (ASD) research portrays a mixed picture of attentional abilities with demonstrations of enhancements (e.g., superior visual search) and deficits (e.g., higher distractibility). Here we test a potential resolution derived from the Load Theory of Attention (e.g., Lavie, 2005). In Load Theory, distractor processing depends on the perceptual load of the task and as such can only be eliminated under high load that engages full capacity. We hypothesize that ASD involves enhanced perceptual capacity, leading to the superior performance and increased distractor processing previously reported. Using a signal-detection paradigm, we test this directly and demonstrate that, under higher levels of load, perceptual sensitivity was reduced in typical adults but not in adults with ASD. These findings confirm our hypothesis and offer a promising solution to the previous discrepancies by suggesting that increased distractor processing in ASD results not from a filtering deficit but from enhanced perceptual capacity.

  18. Movement detection impaired in patients with knee osteoarthritis compared to healthy controls

    DEFF Research Database (Denmark)

    Lund, H; Juul-Kristensen, Birgit; Hansen, Klaus

    2009-01-01

    The purpose of this study was to clarify whether osteoarthritis (OA) patients have a localized or a generalized reduction in proprioception. Twenty one women with knee OA (mean age [SD]: 57.1 [12.0] years) and 29 healthy women (mean age [SD]: 55.3 [10.1] years) had their joint position sense (JPS......) and threshold to detection of a passive movement (TDPM) measured in both knees and elbows. JPS was measured as the participant's ability to actively reproduce the position of the elbow and knee joints. TDPM was measured as the participant's ability to recognize a passive motion of the elbow and knee joints....... The absolute error (AE) for JPS (i.e., absolute difference in degrees between target and estimated position) and for TDPM (i.e., the difference in degrees at movement start and response when recognizing the movement) was calculated. For TDPM a higher AE (mean [SE]) was found in the involved knees in patients...

  19. Usual normalization strategies for gene expression studies impair the detection and analysis of circadian patterns.

    Science.gov (United States)

    Figueredo, Diego de Siqueira; Barbosa, Mayara Rodrigues; Coimbra, Daniel Gomes; Dos Santos, José Luiz Araújo; Costa, Ellyda Fernanda Lopes; Koike, Bruna Del Vechio; Alexandre Moreira, Magna Suzana; de Andrade, Tiago Gomes

    2018-03-01

    Recent studies have shown that transcriptomes from different tissues present circadian oscillations. Therefore, the endogenous variation of total RNA should be considered as a potential bias in circadian studies of gene expression. However, normalization strategies generally include the equalization of total RNA concentration between samples prior to cDNA synthesis. Moreover, endogenous housekeeping genes (HKGs) frequently used for data normalization may exhibit circadian variation and distort experimental results if not detected or considered. In this study, we controlled experimental conditions from the amount of initial brain tissue samples through extraction steps, cDNA synthesis, and quantitative real time PCR (qPCR) to demonstrate a circadian oscillation of total RNA concentration. We also identified that the normalization of the RNA's yield affected the rhythmic profiles of different genes, including Per1-2 and Bmal1. Five widely used HKGs (Actb, Eif2a, Gapdh, Hprt1, and B2m) also presented rhythmic variations not detected by geNorm algorithm. In addition, the analysis of exogenous microRNAs (Cel-miR-54 and Cel-miR-39) spiked during RNA extraction suggests that the yield was affected by total RNA concentration, which may impact circadian studies of small RNAs. The results indicate that the approach of tissue normalization without total RNA equalization prior to cDNA synthesis can avoid bias from endogenous broad variations in transcript levels. Also, the circadian analysis of 2 -Cycle threshold (Ct) data, without HKGs, may be an alternative for chronobiological studies under controlled experimental conditions.

  20. Myocardial Scintigraphy in the Evaluation of Cardiac Events in Patients without Typical Symptoms

    Directory of Open Access Journals (Sweden)

    Paola Emanuela Poggio Smanio

    2015-01-01

    Full Text Available Background: Cardiovascular disease is a leading cause of death in the world and in Brazil. Myocardial scintigraphy is an important noninvasive method for detecting ischemia in symptomatic patients, but its use in asymptomatic ones or those with atypical symptoms is yet to be defined. Objective: To verify the presence of major cardiac events in asymptomatic patients or those with atypical symptoms (atypical chest pain or dyspnea that underwent myocardial scintigraphy (MS, over a period of 8 years. Secondary objectives were to identify cardiac risk factors associated with myocardial scintigraphy abnormalities and possible predictors for major cardiac events in this group. Methods: This was a retrospective, observational study using the medical records of 892 patients that underwent myocardial scintigraphy between 2005 and 2011 and who were followed until 2013 for assessment of major cardiac events and risk factors associated with myocardial scintigraphy abnormalities. Statistical analysis was performed by Fisher’s exact test, logistic regression and Kaplan-Meyer survival curves, with statistical significance being set at p ≤ 0.05. Results: Of the total sample, 52.1% were men, 86.9% were hypertensive, 72.4% had hyperlipidemia, 33.6% were diabetic, and 12.2% were smokers; 44.5% had known coronary artery disease; and 70% had high Framingham score, 21.8% had moderate and 8% had low risk. Of the myocardial scintigraphies, 58.6% were normal, 26.1% suggestive of fibrosis and 15.3% suggestive of ischemia. At evolution, 13 patients (1.5% had non-fatal myocardial infarction and six individuals (0.7% died. The group with normal myocardial scintigraphy showed longer period of time free of major cardiac events, non-fatal myocardial infarction (p = 0.036 and death. Fibrosis in the myocardial scintigraphy determined a 2.4-fold increased risk of non-fatal myocardial infarction and five-fold higher risk of death (odds ratio: 2.4 and 5.7, respectively; p = 0

  1. Myocardial Scintigraphy in the Evaluation of Cardiac Events in Patients without Typical Symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Smanio, Paola Emanuela Poggio, E-mail: pgmsmanio@gmail.com; Silva, Juliana Horie; Holtz, João Vitor; Ueda, Leandro; Abreu, Marilia; Marques, Carlindo; Machado, Leonardo [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP - Brazil Mailing (Brazil)

    2015-08-15

    Cardiovascular disease is a leading cause of death in the world and in Brazil. Myocardial scintigraphy is an important noninvasive method for detecting ischemia in symptomatic patients, but its use in asymptomatic ones or those with atypical symptoms is yet to be defined. To verify the presence of major cardiac events in asymptomatic patients or those with atypical symptoms (atypical chest pain or dyspnea) that underwent myocardial scintigraphy (MS), over a period of 8 years. Secondary objectives were to identify cardiac risk factors associated with myocardial scintigraphy abnormalities and possible predictors for major cardiac events in this group. This was a retrospective, observational study using the medical records of 892 patients that underwent myocardial scintigraphy between 2005 and 2011 and who were followed until 2013 for assessment of major cardiac events and risk factors associated with myocardial scintigraphy abnormalities. Statistical analysis was performed by Fisher’s exact test, logistic regression and Kaplan-Meyer survival curves, with statistical significance being set at p ≤ 0.05. Of the total sample, 52.1% were men, 86.9% were hypertensive, 72.4% had hyperlipidemia, 33.6% were diabetic, and 12.2% were smokers; 44.5% had known coronary artery disease; and 70% had high Framingham score, 21.8% had moderate and 8% had low risk. Of the myocardial scintigraphies, 58.6% were normal, 26.1% suggestive of fibrosis and 15.3% suggestive of ischemia. At evolution, 13 patients (1.5%) had non-fatal myocardial infarction and six individuals (0.7%) died. The group with normal myocardial scintigraphy showed longer period of time free of major cardiac events, non-fatal myocardial infarction (p = 0.036) and death. Fibrosis in the myocardial scintigraphy determined a 2.4-fold increased risk of non-fatal myocardial infarction and five-fold higher risk of death (odds ratio: 2.4 and 5.7, respectively; p = 0.043). The occurrence of major cardiac events in 8 years

  2. Fracture healing: Quantitative three-phase bone scintigraphy as a prognostic factor

    International Nuclear Information System (INIS)

    Dodig, D.; Kasal, B.; Kragic-Pranic, A.; Predic, P.

    2002-01-01

    Aim: Careful clinical examination and conventional radiography, together with other standard methods for evaluation of bone fracture healing, are frequently inconclusive. Furthermore, it is difficult to predict the complications of healing on the basis of clinical and radiographic findings only. Bone scintigraphy plays an important role in detecting bone fractures. This method is very sensitive, but not enough specific. The aim of this work was to evaluate the role of three-phase bone scintigraphy in the healing prognosis of long bone fractures. Material and Methods: We evaluated the three elements (perfusion, blood pool and static image) of three-phase bone scintigraphy in early prognosis of the course of fracture healing in patients with fractures of femur or tibia. Three-phase bone scintigraphy was performed in 73 patients. The patients were divided into 4 groups according to X-ray and clinical examination: 1) Non operated patients with stable fracture, 2) Operated patients with unstable fracture (infection), 3) Fractures with delayed union, 4) Patients with pseudoarthrosis. Using region of interest (ROI) method we compared the activity on the site of fracture with the activity on the symmetrical place in the healthy bone. The relative indices for each group of patients and for each element of three-bone scintigraphy were calculated in order to make possible the follow up of the fracture healing and to obtain data for prognosis and evaluation of possible complications. Results: The most valuable results were obtained by quantitative analysis of perfusion data immediately after trauma and 2-3 weeks later. Our results show a high diagnostic accuracy in identifying infection by perfusion scintigrams immediately after trauma. The perfusion indices obtained immediately and after 2-3 weeks could predict delayed union after the trauma. Quantitative analysis of blood pool phase gave no data of clinical significance in distinguishing various pathologies. Conclusion: Our

  3. Diagnostic value of static and dynamic scintigraphy in diagnosis of acute respiratory distress syndrome in the course of sepsis. Part 2. Lung aerosol scintigraphy

    International Nuclear Information System (INIS)

    Jurgilewicz, D.; Rogowski, F.; Malinowska, L.

    1997-01-01

    Rapid increase in permeability of functionally and/or structurally damaged alveolar-capillary barrier is the pivotal factor in non-cardiogenic pulmonary edema development. Rate of exudative changes progress in the lungs decides about prognosis in patients with this serious, over 50% death rate, syndrome. The aim of the study was to estimate the usefulness of dynamic lung scintigraphy in diagnosis of gas exchange abnormalities in sepsis and ARDS. Aerosol scintigraphy with pulmonary clearance of DTPA in 6 septic and in 6 ARDS patients were performed. Studies were done using planar gamma camera, type MB9200, in A-P projection. They were analyzed with the modified NMS Warsaw Polytechnic computer program. Aerosol scintiscans demonstrated very irregular borderlines of both lungs, features of marked impairment in ventilation (with foci of increased radioactivity in the view of main bronchi) and about 2.5-fold faster pulmonary clearance of DTPA in ARDS patients comparing to sepsis and control gr