WorldWideScience

Sample records for scintigraphic phase image

  1. 123I-BMIPP delayed scintigraphic imaging in patients with chronic heart failure

    International Nuclear Information System (INIS)

    Kida, Keisuke; Akashi, Yoshihiro J.; Yoneyama, Kihei; Shimokawa, Mitsuhiro; Musha, Haruki

    2008-01-01

    The objective of the present study was to clarify the ability of 123 I-beta-methyl-iodophenylpentadecanoic acid ( 123 I-BMIPP) to evaluate the heart-to-mediastinum (H/M) ratio and myocardial global washout rate (WR) in patients with chronic heart failure (CHF). The severity of CHF was evaluated on the basis of the New York Heart Association (NYHA) classification. Twenty patients with CHF (13 with idiopathic dilated cardiomyopathy and 7 with ischemic cardiomyopathy) and 11 age-matched controls underwent myocardial radionuclide imaging. Scintigraphic images were obtained from each participant at the early (30 min following radio-isotope injection) and late (4 h) phases using 123 I-BMIPP. The H/M ratio and WR were calculated from planar images. Concentrations of plasma brain natriuretic peptide (BNP) were measured prior to the scintigraphic study. The 123 I-BMIPP uptake of early H/M and global WR did not significantly differ among groups, but uptake of delayed H/M was significantly lower in patients with NYHA class III than in controls (control 2.47±0.39; class III 1.78±0.28 P 123 I-BMIPP uptake of delayed H/M enhances the image of CHF severity. The myocardial WR of 123 I-BMIPP also effectively depicted the severity of CHF. (author)

  2. Scintigraphic imaging of endocrine organs

    International Nuclear Information System (INIS)

    Gross, M.D.; Shapiro, B.; Thrall, J.H.; Freitas, J.E.; Beierwaltes, W.H.

    1984-01-01

    The nuclear medicine approach to the portrayal of endocrine organs is unique; the scintigraphic images provide not only anatomic and localization information, but in many instances allow a quantitative assessment of organ function. The ability to image endocrine glands is based upon the design of radionuclides and radiopharmaceuticals with characteristics to take advantage of many unique and specific biochemical and advantage of many unique and specific biochemical and metabolic functions of these tissues. The recent introduction of new radiopharmaceutical and tracers has provided the consulting endocrinologist with imaging procedures that allow localization and functional characterization not available by other single, noninvasive diagnostic modalities. This review will serve as an update of the available techniques to image and quantitate the function of the endocrine glands using the nuclear medicine approach

  3. Computer processing of the scintigraphic image using digital filtering techniques

    International Nuclear Information System (INIS)

    Matsuo, Michimasa

    1976-01-01

    The theory of digital filtering was studied as a method for the computer processing of scintigraphic images. The characteristics and design techniques of finite impulse response (FIR) digital filters with linear phases were examined using the z-transform. The conventional data processing method, smoothing, could be recognized as one kind of linear phase FIR low-pass digital filtering. Ten representatives of FIR low-pass digital filters with various cut-off frequencies were scrutinized from the frequency domain in one-dimension and two-dimensions. These filters were applied to phantom studies with cold targets, using a Scinticamera-Minicomputer on-line System. These studies revealed that the resultant images had a direct connection with the magnitude response of the filter, that is, they could be estimated fairly well from the frequency response of the digital filter used. The filter, which was estimated from phantom studies as optimal for liver scintigrams using 198 Au-colloid, was successfully applied in clinical use for detecting true cold lesions and, at the same time, for eliminating spurious images. (J.P.N.)

  4. Statistical and heuristic image noise extraction (SHINE): a new method for processing Poisson noise in scintigraphic images

    International Nuclear Information System (INIS)

    Hannequin, Pascal; Mas, Jacky

    2002-01-01

    Poisson noise is one of the factors degrading scintigraphic images, especially at low count level, due to the statistical nature of photon detection. We have developed an original procedure, named statistical and heuristic image noise extraction (SHINE), to reduce the Poisson noise contained in the scintigraphic images, preserving the resolution, the contrast and the texture. The SHINE procedure consists in dividing the image into 4 x 4 blocks and performing a correspondence analysis on these blocks. Each block is then reconstructed using its own significant factors which are selected using an original statistical variance test. The SHINE procedure has been validated using a line numerical phantom and a hot spots and cold spots real phantom. The reference images are the noise-free simulated images for the numerical phantom and an extremely high counts image for the real phantom. The SHINE procedure has then been applied to the Jaszczak phantom and clinical data including planar bone scintigraphy, planar Sestamibi scintigraphy and Tl-201 myocardial SPECT. The SHINE procedure reduces the mean normalized error between the noisy images and the corresponding reference images. This reduction is constant and does not change with the count level. The SNR in a SHINE processed image is close to that of the corresponding raw image with twice the number of counts. The visual results with the Jaszczak phantom SPECT have shown that SHINE preserves the contrast and the resolution of the slices well. Clinical examples have shown no visual difference between the SHINE images and the corresponding raw images obtained with twice the acquisition duration. SHINE is an entirely automatic procedure which enables halving the acquisition time or the injected dose in scintigraphic acquisitions. It can be applied to all scintigraphic images, including PET data, and to all low-count photon images

  5. Role of intensity transformation function for enhancement of bone scintigraphic images.

    Science.gov (United States)

    Pandey, Anil Kumar; Dhiman, Vishali; Sharma, Akshima; ArunRaj, Sreedharan Thankarajan; Baghel, Vivek; Patel, Chetan; Sharma, Param Dev; Bal, Chandrasekhar; Kumar, Rakesh

    2018-03-29

    The bone scintigraphic image might exceed the dynamic range (the ratio between the highest and the lowest brightness a monitor is capable of displaying) of display monitor. In this case, a high intensity area, and loss of the details of other structures in the displayed image makes the clinical interpretation a challenging task. We have investigated the role of intensity transformation function for enhancement of these types of images. Methods: Forty high dynamic range bone scintigraphic images were processed using intensity transformation (IT) function. The IT function has two parameters: threshold and slope. Keeping the threshold equal to mean counts of the image, the value of slope was varied from 1 to 20. In-house application program written in MATLAB R2013b was used to process images. Twenty output images corresponding to one input image were visually inspected by two experienced nuclear medicine (NM) physicians to select diagnostic quality images, and from their selection the standardized slope (value of slope parameter) that produced maximum numbers of diagnostic images was determined. They also rated the image quality of input and output images (at standardized slope) on scale 1 to 5 [where 1 is for poor and 5 if for the excellent diagnostic quality]. Student's t-test was used to test the significance of difference between the mean image quality score assigned to input and processed images at significance level α = 0.05. Results: The application of IT functions with standardized parameters significantly improved the quality of high dynamic range bone scintigraphic images ( P enhancement. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. 123I-BMIPP delayed scintigraphic imaging in patients with chronic heart failure.

    Science.gov (United States)

    Kida, Keisuke; Akashi, Yoshihiro J; Yoneyama, Kihei; Shimokawa, Mitsuhiro; Musha, Haruki

    2008-11-01

    The objective of the present study was to clarify the ability of 123I-beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) to evaluate the heart-to-mediastinum (H/M) ratio and myocardial global washout rate (WR) in patients with chronic heart failure (CHF). The severity of CHF was evaluated on the basis of the New York Heart Association (NYHA) classification. Twenty patients with CHF (13 with idiopathic dilated cardiomyopathy and 7 with ischemic cardiomyopathy) and 11 age-matched controls underwent myocardial radionuclide imaging. Scintigraphic images were obtained from each participant at the early (30 min following radio-isotope injection) and late (4 h) phases using 123I-BMIPP. The H/M ratio and WR were calculated from planar images. Concentrations of plasma brain natriuretic peptide (BNP) were measured prior to the scintigraphic study. The 123I-BMIPP uptake of early H/M and global WR did not significantly differ among groups, but uptake of delayed H/M was significantly lower in patients with NYHA class III than in controls (control 2.47 +/- 0.39; class III 1.78 +/- 0.28, P < 0.05). The uptake of delayed H/M and global WR correlated with plasma log BNP in all participants (r = -0.38, P < 0.05; 0.43, P < 0.05, respectively). These data suggest that 123I-BMIPP uptake of delayed H/M enhances the image of CHF severity. The myocardial WR of 123I-BMIPP also effectively depicted the severity of CHF.

  7. Is there a role for scintigraphic imaging of bone manifestations in Gaucher disease? A review of the literature

    International Nuclear Information System (INIS)

    Mikosch, P.; State Hospital Klagenfurt; Kohlfuerst, S.; Gallowitsch, H.J.; Kresnik, E.; Lind, P.; Mehta, A.B.; Hughes, D.A.

    2008-01-01

    Gaucher disease is the most prevalent inherited, lysosomal storage disease and is caused by deficient activity of the enzyme β-glucocerebrosidase. Bone and bone marrow alterations are frequent in the most prevalent non-neuronopathic form of Gaucher disease. Imaging of bone manifestations in Gaucher disease is performed by a variety of imaging methods, conventional X-ray and MRI as the most frequently and most important ones. However, different modalities of scintigraphic imaging have also been used. This article gives an overview on scintigraphic imaging with respect to bone manifestations in Gaucher disease discussing the advantages and limitations of scintigraphic imaging in comparison to other imaging methods. (orig.)

  8. Temporal contrast enhancement and parametric imaging for the visualisation of time patterns in dynamic scintigraphic imaging

    International Nuclear Information System (INIS)

    Deconinck, F.; Bossuyt, A.; Lepoudre, R.

    1982-01-01

    Image contrast, photon noise and sampling frequency limit the visual extraction of relevant temporal information in scintigraphic image series. When the Unitation is mainly due to low temporal contrast, temporal contrast enhancement will strongly improve the perceptibility of time patterns in the series. When the limitation is due to photon noise and limited temporal sampling, parametric imaging by means of the Hadamard transform can visualise temporal patterns. (WU)

  9. Gamma camera with an original system of scintigraphic image printing incorporated

    International Nuclear Information System (INIS)

    Roux, G.

    A new gamma camera has been developed, using Anger's Principle to localise the scintillations and incorporating the latest improvements which give a standard of efficiency at present competitive for this kind of apparatus. In the general design of the system special care was devoted to its ease of employment and above all to the production of high-quality scintigraphic images, the recording of images obtained from the gamma camera posing a problem to which a solution is proposed. This consists in storing all the constituent data of an image in a cell matrix of format similar to the scope of the object, the superficial information density of the image being represented by the cell contents. When the examination is finished a special printer supplies a 35x43 cm 2 document in colour on paper, or in black and white on radiological film, at 2:1 or 1:1 magnifications. The laws of contrast representation by the colours or shades of grey are chosen a posteriori according to the organ examined. Documents of the same quality as those so far supplied by a rectilinear scintigraph are then obtained with the gamma camera, which offers its own advantages in addition. The first images acquired in vivo with the whole system, gamma camera plus printer, are presented [fr

  10. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru [Chiba Univ. (Japan). School of Medicine

    1994-09-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author).

  11. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru

    1994-01-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author)

  12. Scintigraphic images of bacterial infection using aptamers directly labeled with 99mTc

    International Nuclear Information System (INIS)

    Santos, S.R.; Correa, C.R.; Andrade, A.S.R.; Barros, A.L.B.; Diniz, S.O.F.; Cardoso, V.N.

    2015-01-01

    Staphylococcus aureus is specie of great medical importance and is the most commonly agent found in infections of soft tissues, bone infections and bone prostheses. In this study, aptamers selected to S. aureus were labeled by the direct method with 99m Tc and used for bacterial infection identification by scintigraphy. The radiolabeled aptamers radiochemical purity and stability were assessed by thin-layer chromatography (TLC). Three groups of Swiss mice (n=6) were used for the scintigraphic imaging studies. The first group was infected intramuscularly in the right thigh with S. aureus, the second group with C. albicans and the third group received zymosan to induce aseptic inflammation. After 24 h, radiolabeled aptamers (18 MBq) were injected by the tail vein. Scintigraphic images were acquired at 1 h and 4 h postinjection. The radiolabeling yield with 99m Tc was over 90%. The radiolabeled aptamers were stable in 0.9% saline, plasma and cysteine excess. The scintigraphic image profiles showed high uptake in the kidneys and bladder in all groups, indicating a main renal excretion consistent with the hydrophilic nature of the molecule. No accumulation of radioactivity was observed in the thyroid, stomach, liver and spleen, indicating acceptable levels of radiochemical impurities. The group infected with S. aureus showed a visible uptake in the infected right thigh at 1 h post-injection. For the control groups (C. albicans and zymosan) visible differences between the right and left thighs were not observed. The radiolabeled aptamers were able to distinguish aseptic inflammation from bacterial infection and bacterial from fungal infection. (author)

  13. Scintigraphic images of bacterial infection using aptamers directly labeled with {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Santos, S.R.; Correa, C.R.; Andrade, A.S.R., E-mail: sararoberta7@hotmail.com, E-mail: crisrcorrea@gmail.com, E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Barros, A.L.B.; Diniz, S.O.F.; Cardoso, V.N., E-mail: brancodebarros@yahoo.com.br, E-mail: valbertcardoso@yahoo.com.br, E-mail: simoneodilia@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Farmacia. Departamento de Analises Clinicas e Toxicologicas

    2015-07-01

    Staphylococcus aureus is specie of great medical importance and is the most commonly agent found in infections of soft tissues, bone infections and bone prostheses. In this study, aptamers selected to S. aureus were labeled by the direct method with {sup 99m}Tc and used for bacterial infection identification by scintigraphy. The radiolabeled aptamers radiochemical purity and stability were assessed by thin-layer chromatography (TLC). Three groups of Swiss mice (n=6) were used for the scintigraphic imaging studies. The first group was infected intramuscularly in the right thigh with S. aureus, the second group with C. albicans and the third group received zymosan to induce aseptic inflammation. After 24 h, radiolabeled aptamers (18 MBq) were injected by the tail vein. Scintigraphic images were acquired at 1 h and 4 h postinjection. The radiolabeling yield with {sup 99m}Tc was over 90%. The radiolabeled aptamers were stable in 0.9% saline, plasma and cysteine excess. The scintigraphic image profiles showed high uptake in the kidneys and bladder in all groups, indicating a main renal excretion consistent with the hydrophilic nature of the molecule. No accumulation of radioactivity was observed in the thyroid, stomach, liver and spleen, indicating acceptable levels of radiochemical impurities. The group infected with S. aureus showed a visible uptake in the infected right thigh at 1 h post-injection. For the control groups (C. albicans and zymosan) visible differences between the right and left thighs were not observed. The radiolabeled aptamers were able to distinguish aseptic inflammation from bacterial infection and bacterial from fungal infection. (author)

  14. Evaluation by scintigraphic images of musculoskeletal infection with 99mTc ciprofloxacin

    International Nuclear Information System (INIS)

    Casacó, C.A.; Hernández, A.; Perera, A.; Prats, A.; Batista, J.F.; Torres, L.A.; Quesada, R.; Sánchez, Y.; Valladares, L.; Sánchez, E.L.; Marrero, L.O.; Mustelier, E.

    2016-01-01

    Introduction: Infectious diseases present high morbidity and mortality in all countries, especially in the third world. In Cuba between 2005 and 2014, approximately 1.3% of the total deaths were killed. Orthopedic infections are among the most common. The scintigraphic methods currently used are not able to discern between a septic focus and a sterile inflammation. Radiological methods detect a bone infection only when there is significant anatomical damage. Ciprofloxacin as a drug binds and inhibits topoisomerase II or bacterial gyrase DNA. Objective: to evaluate the efficacy of 99m Tc-ciprofloxacin in the detection of osteo-articular bacterial processes. Materials and Methods: An experimental, cross-sectional, cross-sectional study was conducted involving 258 patients with suspected osteoarticular infectious processes. The presence of the lesion and the quantification and intensity of uptake in the foci of infection in images with 99m Tc-MDP (3h post-administration) and 99m Tc-ciprofloxacin (1, 4 and 24h post-administration) were visually determined. Studies of 99m Tc-ciprofloxacin were compared with Culture / Biopsy results. Results: The germ that most frequently appears in infected osteo-articular sites is staphilococcusaureus. No adverse effects were detected in any of the subjects studied. Studies with 99m Tc-MDP allow delineating infected areas but are not specific. 99mTc-ciprofloxacin shows the sites of active osteo-articular bacterial infection and when it is fixed in a septic focus gives intense captures at both 4 and 24 hours. It exhibits a sensitivity similar to 99mTc-MDP, but a significantly higher specificity. Conclusions: Scintigraphic images with 99m Tc-ciprofloxacin show sites of active osteo-articular bacterial infection with a specificity significantly higher than 99m Tc-MDP. The microbiological and scintigraphic results were positive for sepsis in 122 patients out of 219 who were sampled.

  15. Scintigraphic appearance of the piriformis muscle syndrome

    International Nuclear Information System (INIS)

    Karl, R.D. Jr.; Yedinak, M.A.; Hartshorne, M.F.; Cawthon, M.A.; Bauman, J.M.; Howard, W.H.; Bunker, S.R.

    1985-01-01

    This is the first report in the nuclear medicine literature of the scintigraphic appearance of the piriformis muscle syndrome. This syndrome previously has been thought to be a purely clinical diagnosis and imaging modalities have been ignored. However, its confusing clinical presentation can lead to unnecessary surgical exploration. This case is presented to illustrate the characteristic scintigraphic pattern and suggest the role of nuclear medicine scanning in establishing the diagnosis

  16. Scintigraphic detection of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging

    Energy Technology Data Exchange (ETDEWEB)

    Georgiou, E C; Arkas, A Z; Alevizaki, C C; Gnafakis, N [Evangelismos Hospital, Athens (Greece). Dept. of Endocrinology and Radioisotopes; Evangelismos Hospital, Athens (Greece). Gynaecology Clinic)

    1979-12-01

    Three cases of scintigraphic visualization of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging are presented, i.e. one case of fibrothecoma ('cold' area visualization) and two cases of fibromyoma ('hot' area visualization). It is suggested that this technique may be useful in the preoperative evaluation of gynaecological tumours and their vascularity.

  17. Congenital vascular malformations in scintigraphic evaluation

    International Nuclear Information System (INIS)

    Pilecki, Stanisław; Gierach, Marcin; Gierach, Joanna; Świętaszczyk, Cyprian; Junik, Roman; Lasek, Władysław

    2014-01-01

    Congenital vascular malformations are tumour-like, non-neoplastic lesions caused by disorders of vascular tissue morphogenesis. They are characterised by a normal cell replacement cycle throughout all growth phases and do not undergo spontaneous involution. Here we present a scintigraphic image of familial congenital vascular malformations in two sisters. A 17-years-old young woman with a history of multiple hospitalisations for foci of vascular anomalies appearing progressively in the upper and lower right limbs, chest wall and spleen. A Parkes Weber syndrome was diagnosed based on the clinical picture. Due to the occurrence of new foci of malformations, a whole-body scintigraphic examination was performed. A 12-years-old girl reported a lump in the right lower limb present for approximately 2 years, which was clinically identified as a vascular lesion in the area of calcaneus and talus. Phleboscintigraphy visualized normal radiomarker outflow from the feet via the deep venous system, also observed in the superficial venous system once the tourniquets were released. In static and whole-body examinations vascular malformations were visualised in the area of the medial cuneiform, navicular and talus bones of the left foot, as well as in the projection of right calcaneus and above the right talocrural joint. People with undiagnosed disorders related to the presence of vascular malformations should undergo periodic follow-up to identify lesions that may be the cause of potentially serious complications and to assess the results of treatment. Presented scintigraphic methods may be used for both diagnosing and monitoring of disease progression

  18. Scintigraphic demonstration of single- or two-phase gastric emptying in diabetics

    International Nuclear Information System (INIS)

    Eikman, E.A.; Leichter, S.; Waldholtz, B.; Tenorio, L.; Brady, P.

    1989-01-01

    This paper discusses how a modified scintigraphic test of gastric emptying revealed two types of abnormal gastric emptying in diabetic patients. After ingestion of 100 mL of cooked egg whites labeled with 0.5 mCi of Tc-99m sulfur colloid, the geometric mean stomach radioactivity was recorded serially for 90 minutes. Linear regression computed for the log of radioactivity versus time facilitated recognition of changes in gastric emptying. In 16 of 25 consecutive diabetic patients with postprandial symptoms, initial slow emptying (half-life,>100 minutes) was observed. Single-phase emptying was shown in seven of these patients. In nine patients, the slow-emptying phase lasted up to 50 minutes, followed by a distinct second phase of normal or rapid emptying (half-life, <40 minutes). The existence of different gastric emptying implies differing mechanisms of delay and may be important in treatment

  19. Scintigraphic demonstration of splenosis

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, C.A.; Sakimura, I.T.; Siegel, M.E.

    1986-03-01

    A case of splenosis, or the autotransplantation of splenic tissue following trauma, was encountered unexpectedly on a routine liver scan performed in the workup of alcoholic liver disease. Confirmatory scintigraphic images using Tc-99m labeled, heat-damaged, autologous erythrocytes are presented with CT scans of the abdomen.

  20. Scintigraphic imaging of Staphylococcus aureus infection using 99mTc radiolabeled aptamers.

    Science.gov (United States)

    Santos, Sara Roberta Dos; de Sousa Lacerda, Camila Maria; Ferreira, Iêda Mendes; de Barros, André Luís Branco; Fernandes, Simone Odília; Cardoso, Valbert Nascimento; de Andrade, Antero Silva Ribeiro

    2017-10-01

    Staphylococcus aureus is a specie of great medical importance associated with many infections as bacteremia and infective endocarditis as well as osteoarticular, skin and soft tissue, pleuropulmonary, and device related infections. Early identification of infectious foci is crucial for successful treatment. Scintigraphy could contribute to this purpose since specific radiotracers were available. Aptamers due to their high specificity have great potential for radiopharmaceuticals development. In the present study scintigraphic images of S. aureus infectious foci were obtained using specific S. aureus aptamers radiolabeled with 99m Tc. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. The new techniques of scintigraphic imaging

    International Nuclear Information System (INIS)

    Chatal, J.F.

    1990-01-01

    The purpose of scintigraphic imaging is not to explore the morphology of an organ (or its abnormalities) but rather its functional and metabolic characteristics. It is thus important that a molecular structure (e.g., a hormonal receptor or an antigen) closely linked to the functional activity of an organ or tissue be targeted on its cell surface. Such diagnostic targeting requires the synthesis and labeling of a radiopharmaceutical substance specific for the receptor or antigen in question. It also requires a detection system adapted to count rates and signal-to-background ratios (generally moderate). The synthesis of new radiopharmaceutical agents, a critical stage for the future of nuclear medicine, is a long and often risky process in which success is difficult to foresee. Radiolabeling must be stable in vitro and in vivo, and the radiopharmaceutical must subsequently retain its capability of recognizing the targeted molecule. In endocrinology, the exemplary achievement in this direction has been the synthesis of 131 I-6-iodomethylnorcholesterol and 131 I-metaiodobenzylguanidine for functional scintigraphy of the adrenal cortex and medulla. Progress in detection equipment has been marked by the development of monophotonic tomoscintigraphy, using gamma cameras with a revolving head to obtain slices in different spatial planes showing the distribution in the organism of the injected radiopharmaceutical agent [fr

  2. The significance of 123I-BMIPP delayed scintigraphic imaging in cardiac patients.

    Science.gov (United States)

    Akashi, Yoshihiro J; Kida, Keisuke; Suzuki, Kae; Inoue, Koji; Kawasaki, Kensuke; Yamauchi, Masahiro; Musha, Haruki; Anker, Stefan D

    2007-04-25

    Earlier studies have not fully investigated the significance of radionuclide planar imaging in cardiac patients using the fatty acid analogue 123I-beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP). This study was to clarify the effectiveness of 123I-BMIPP in assessing the heart-to-mediastinum ratio (H/M) and myocardial washout rate (WR) in patients with heart disease. Myocardial 123I-BMIPP imaging was performed in 33 patients (20 with chronic heart failure [CHF] and 13 with stable angina pectoris [AP]) and 11 control subjects. Myocardial 123I-BMIPP planner images were obtained 30 min (early image) and 4 h (delayed image) after tracer injection. The left ventricular ejection fraction (LVEF) was measured by quantitative gated single photon emission computed tomography. The concentration of plasma brain natriuretic peptide (BNP) was measured before the scintigraphic study. (1) Delayed H/M was much lower in CHF than in AP (1.93 +/- 0.37 vs. 2.21 +/- 0.38, p acid metabolism disorders in patients with heart disease in both masked and unmasked conditions.

  3. Three-phase radionuclide bone imaging in sports medicine

    International Nuclear Information System (INIS)

    Rupani, H.D.; Holder, L.E.; Espinola, D.A.; Engin, S.I.

    1985-01-01

    Three-phase radionuclide bone (TPB) imaging was performed on 238 patients with sports-related injuries. A wide variety of lesions was encountered, but the most frequent lesions seen were stress fractures of the lower part of the leg at the junction of the middle and distal thirds of the posterior tibial cortex (42 of 79 lesions). There were no differences in the type, location, or distribution of lesions between males and females or between competitive and noncompetitive athletes. In 110 cases, bone stress lesions were often diagnosed when radiographs were normal, whereas subacute or chronic soft-tissue abnormalities had few specific scintigraphic features. TPB imaging provides significant early diagnostic information about bone stress lesions. Normal examination results (53 cases) exclude underlying osseous pathologic conditions

  4. Scintigraphic imaging with 99mTc- exorphin C in rabbits

    International Nuclear Information System (INIS)

    Ertay, T.; Uenak, P.; Tasci, C.; Zihnioglu, F.; Durak, H.

    2005-01-01

    Exorphin C is a peptide with five amino acids [(Tyr-Pro-Ile-Ser-Leu) Trifluoroacetate salt] (Sigma) that has an affinity to opioid receptor-expressing tissues and tumors. Exorphin-C was labeled with 99m Tc using glucoheptonate (GH) as bifunctional chelating agent. Then, we investigated its radiopharmaceutical potential as opioid receptor-expressing tissue on rabbits. Quality controls were performed by ITLC, paper electrophoresis and HPLC. Labeling efficiency was higher than 98%. The compound was stable for at least 5 h at room temperature. Scintigraphic imaging with 99m Tc-GH-exorphin C ( 99m Tc-GE) was performed on male Albino rabbits. Static images were obtained from anterior projection using a Camstar XR/T gamma camera at several time intervals. Although a significant amount of activity was seen in the brain, less activity was seen on receptor saturation studies at 30 min. Slight hepatobiliary excretion was seen, though the main excretion route was renal. After saturating, the receptor hepatobiliary excretion was not seen; the only excretion route was renal

  5. A paper sheet phantom for scintigraphic planar imaging. Usefulness of pouch-laminated paper source

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Teraoka, Satomi; Murakami, Tomonori; Kojima, Akihiro; Matsumoto, Masanori

    2007-01-01

    In order to perform experimental measurements for evaluation of imaging device's performance, data acquisition technique, and clinical images on scintigraphic imaging, many kinds of phantoms are employed. However, since these materials are acrylic and plastic, the thickness and quality of those materials cause attenuation and scatter in itself. We developed a paper sheet phantom sealed with a pouch laminator, which can be a true radioactive source in air. In this study, the paper sheet phantom was compared to the acrylic liver phantom, with the thickness of 2 cm, which is commercially available. The results showed that although some scatter counts were contained within the image of the acrylic liver phantom, there were few scattered photons in the paper sheet phantom image. Furthermore, this laminated paper sheet phantom made handling of the source and its waste easier. If the paper sheet phantom will be designed more sophisticatedly, it becomes a useful tool for planar imaging experiments. (author)

  6. 99mTc-MDP combined blood pool and bone phase radionuclide imaging in papain-injected carpal joints

    International Nuclear Information System (INIS)

    Metcalf, M.R.; Twardock, A.R.; Sanecki, R.K.

    1985-01-01

    Scintigraphic changes, i.e., increased activity, were induced by 1% papain, dissolved in phosphate-buffered physiologic saline (pH 7.4), injected into one antebrachiocarpal joint in each of eight dogs. Scintigraphic evaluation was by the use of combined blood pool and bone phase scintigraphy of affected and normal carpi over a 28-day period. The qualitative and quantitative scintigraphic appearance in injected carpal joints were very similar in both blood pool and bone phases. The clinical use of combined blood pool and bone phase scintigraphy to diagnose early inflammatory joint changes appears limited

  7. Accurate means of detecting and characterizing abnormal patterns of ventricular activation by phase image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Botvinick, E.H.; Frais, M.A.; Shosa, D.W.; O' Connell, J.W.; Pacheco-Alvarez, J.A.; Scheinman, M.; Hattner, R.S.; Morady, F.; Faulkner, D.B.

    1982-08-01

    The ability of scintigraphic phase image analysis to characterize patterns of abnormal ventricular activation was investigated. The pattern of phase distribution and sequential phase changes over both right and left ventricular regions of interest were evaluated in 16 patients with normal electrical activation and wall motion and compared with those in 8 patients with an artificial pacemaker and 4 patients with sinus rhythm with the Wolff-Parkinson-White syndrome and delta waves. Normally, the site of earliest phase angle was seen at the base of the interventricular septum, with sequential change affecting the body of the septum and the cardiac apex and then spreading laterally to involve the body of both ventricles. The site of earliest phase angle was located at the apex of the right ventricle in seven patients with a right ventricular endocardial pacemaker and on the lateral left ventricular wall in one patient with a left ventricular epicardial pacemaker. In each case the site corresponded exactly to the position of the pacing electrode as seen on posteroanterior and left lateral chest X-ray films, and sequential phase changes spread from the initial focus to affect both ventricles. In each of the patients with the Wolff-Parkinson-White syndrome, the site of earliest ventricular phase angle was located, and it corresponded exactly to the site of the bypass tract as determined by endocardial mapping. In this way, four bypass pathways, two posterior left paraseptal, one left lateral and one right lateral, were correctly localized scintigraphically. On the basis of the sequence of mechanical contraction, phase image analysis provides an accurate noninvasive method of detecting abnormal foci of ventricular activation.

  8. Accurate means of detecting and characterizing abnormal patterns of ventricular activation by phase image analysis

    International Nuclear Information System (INIS)

    Botvinick, E.H.; Frais, M.A.; Shosa, D.W.; O'Connell, J.W.; Pacheco-Alvarez, J.A.; Scheinman, M.; Hattner, R.S.; Morady, F.; Faulkner, D.B.

    1982-01-01

    The ability of scintigraphic phase image analysis to characterize patterns of abnormal ventricular activation was investigated. The pattern of phase distribution and sequential phase changes over both right and left ventricular regions of interest were evaluated in 16 patients with normal electrical activation and wall motion and compared with those in 8 patients with an artificial pacemaker and 4 patients with sinus rhythm with the Wolff-Parkinson-White syndrome and delta waves. Normally, the site of earliest phase angle was seen at the base of the interventricular septum, with sequential change affecting the body of the septum and the cardiac apex and then spreading laterally to involve the body of both ventricles. The site of earliest phase angle was located at the apex of the right ventricle in seven patients with a right ventricular endocardial pacemaker and on the lateral left ventricular wall in one patient with a left ventricular epicardial pacemaker. In each case the site corresponded exactly to the position of the pacing electrode as seen on posteroanterior and left lateral chest X-ray films, and sequential phase changes spread from the initial focus to affect both ventricles. In each of the patients with the Wolff-Parkinson-White syndrome, the site of earliest ventricular phase angle was located, and it corresponded exactly to the site of the bypass tract as determined by endocardial mapping. In this way, four bypass pathways, two posterior left paraseptal, one left lateral and one right lateral, were correctly localized scintigraphically. On the basis of the sequence of mechanical contraction, phase image analysis provides an accurate noninvasive method of detecting abnormal foci of ventricular activation

  9. Relevance of 123I-BMIPP delayed scintigraphic imaging for patients with angina pectoris ? a pilot study

    OpenAIRE

    Koyama, Kohei; Akashi, Yoshihiro J.; Kida, Keisuke; Suzuki, Kengo; Ishibashi, Yuki; Musha, Haruki; Banach, Maciej

    2011-01-01

    Introduction The study was designed to clarify the role of 123I-?-methyl-iodophenylpentadecanoic acid (123I-BMIPP) in the evaluation of myocardial fatty acid metabolism in patients with stable angina pectoris (AP) before and after percutaneous coronary intervention (PCI). Material and methods Ten controls (mean age: 70.4 ?10.5 years) and 12 patients with AP (mean age: 67.4 ?11.6 years) and single vessel coronary artery disease participated in the radionuclide cardiac study. Scintigraphic imag...

  10. Gallium 67 scintigraphic examination of dilated myocardiopathies

    International Nuclear Information System (INIS)

    Lanfranchi, J.; Sachs, R.N.; Beaudet, B.; Deblock, C.; Tellier, P.

    1989-01-01

    Twenty-seven patients were diagnosed as having dilated cardiomyopathies, based on increases in the cardiothoracic index > 0.50, in the diastolic and systolic diameters of the left ventricle, and in the telediastolic volume of the left ventricle, which was indexed by body surface determined by contrast ventriculography. They underwent gallium 67 scintigraphic examination of the myocardium, in order to non-invasively detect the presence of an inflammatory infiltrate. Fifteen of them also had endomyocardial biopsies and all had virology check-up. The results were disappointing. Only in one case was the scintigraphic image undeniably positive; in 20 other patients the findings were dubious or negative. This technique did not demonstrate the presence of an inflammatory infiltrate and thus an association between myocarditis and dilated cardiomyopathy, could not be established [fr

  11. In vitro evaluation, biodistribution and scintigraphic imaging in mice of radiolabeled anthrax toxins

    International Nuclear Information System (INIS)

    Dadachova, Ekaterina; Rivera, Johanna; Revskaya, Ekaterina; Nakouzi, Antonio; Cahill, Sean M.; Blumenstein, Michael; Xiao, Hui; Rykunov, Dmitry; Casadevall, Arturo

    2008-01-01

    Introduction: There is a lot of interest towards creating therapies and vaccines for Bacillus anthracis, a bacterium which causes anthrax in humans and which spores can be made into potent biological weapons. Systemic injection of lethal factor (LF), edema factor (EF) and protective antigen (PA) in mice produces toxicity, and this protocol is commonly used to investigate the efficacy of specific antibodies in passive protection and vaccine studies. Availability of toxins labeled with imageable radioisotopes would allow to demonstrate their tissue distribution after intravenous injection at toxin concentration that are below pharmacologically significant to avoid masking by toxic effects. Methods: LF, EF and PA were radiolabeled with 188 Re and 99m Tc, and their performance in vitro was evaluated by macrophages and Chinese hamster ovary cells toxicity assays and by binding to macrophages. Scintigraphic imaging and biodistribution of intravenously (IV) injected 99m Tc-and 123 I-labeled toxins was performed in BALB/c mice. Results: Radiolabeled toxins preserved their biological activity. Scatchard-type analysis of the binding of radiolabeled PA to the J774.16 macrophage-like cells revealed 6.6x10 4 binding sites per cell with a dissociation constant of 6.7 nM. Comparative scintigraphic imaging of mice injected intravenously with either 99m Tc-or 123 I-labeled PA, EF and LF toxins demonstrated similar biodistribution patterns with early localization of radioactivity in the liver, spleen, intestines and excretion through kidneys. The finding of renal excretion shortly after IV injection strongly suggests that toxins are rapidly degraded which could contribute to the variability of mouse toxigenic assays. Biodistribution studies confirmed that all three toxins concentrated in the liver and the presence of high levels of radioactivity again implied rapid degradation in vivo. Conclusions: The availability of 188 Re and 99m Tc-labeled PA, LF and EF toxins allowed us to

  12. Scintigraphic anatomy of coronary artery disease in digital thallium-201 myocardial images

    International Nuclear Information System (INIS)

    Wainwright, R.J.

    1981-01-01

    One hundred and eight patients with single and multiple vessel coronary artery disease confirmed by arteriography were evaluated by exercise thallium-201 ( 201 Tl) myocardial scintigraphy to determine the scintigraphic appearances of specific coronary stenoses. In general proximal stenoses caused more widespread, but not necessarily more severe, myocardial tracer deficit, than distal stenoses. In particular, proximal dominant right coronary artery disease was specifically associated with extensive inferior wall tracer deficit in the anterior scintigram, whereas proximal left circumflex disease caused similar tracer depletion best visualised in the left lateral scintigram. A triad of uptake defects was caused by left anterior descending coronary artery disease; one of these defects called 'diagonal window tracer deficit' was the most useful scintigraphic sign distinguishing proximal from distal disease in the left anterior descending coronary artery. Certain scintigraphic patterns of 201 Tl myocardial accumulation appear invaluable in the noninvasive localisation of stenoses within specific coronary arteries and thus may be useful in predicting life-threatening coronary artery disease which should be confirmed by definitive coronary arteriography. The digital 201 Tl myocardial scintigram also provides an independent functional guide to the interpretation of coronary arteriograms and may be helpful in the planning of aortocoronary bypass graft surgery. (author)

  13. NEPHRUS: model of intelligent multilayers expert system for evaluation of the renal system based on scintigraphic images analysis

    International Nuclear Information System (INIS)

    Silva, Jose W.E. da; Schirru, Roberto; Boasquevisque, Edson M.

    1997-01-01

    This work develops a prototype for the system model based on Artificial Intelligence devices able to perform functions related to scintigraphic image analysis of the urinary system. Criteria used by medical experts for analysis images obtained with 99m Tc+DTPA and/or 99m Tc+DMSA were modeled and a multi resolution diagnosis technique was implemented. Special attention was given to the programs user interface design. Human Factor Engineering techniques were considered so as to ally friendliness and robustness. Results obtained using Artificial Neural Networks for the qualitative image analysis and the knowledge model constructed shows the feasibility of Artificial Intelligence implementation that use 'inherent' abilities of each technique in the resolution of diagnosis image analysis problems. (author). 12 refs., 2 figs., 2 tabs

  14. Assessment of scintigraphic image quality in Single Photon Emission Computed Tomography (SPECT) using jaszczak phantom

    International Nuclear Information System (INIS)

    Eduful, E. K

    2012-01-01

    The image quality of scintigraphic images has been improved by applying a MatLab algorithm code and five different filters to an acquired image of the data spectrum (Jaszczak) phantom and the FWHM (resolution) values measured using ImageJ software. The average FWHM value recorded for the acquired image and the Matlab enhanced image were 14.246±0.205 mm and 11.609±1.458 mm respectively. The analyses performed on the acquired image showed improvements in its resolution. Combination of the MatLab algorithm code and the Trous-Wavelet filter gave the best improvement in resolution of the acquired image, with an average FWHM value of 10.261±1.381 mm. This indicates a 27.973% improvement in the FWHM value of the acquired image. The CLAHE filter, Kuwahara filter, Sigma filter Plus and filter rank, improved the resolution of the acquired image by 21.627%, 17.48%, 4.745% and 8.949% respectively. Results from the study indicate that the acquired image was improved in quality by applying the Matlab image enhancement tool and filters. The outcome of this study shows promise in aiding nuclear medicine physicians to make improved diagnostic decisions if applied to clinical cases.(au)

  15. Histiocytosis X: Scintigraphic and roentgenological findings

    International Nuclear Information System (INIS)

    Fezoulidis, I.; Wickenhauser, J.; Schurawitzki, H.; Gritzmann, N.

    1987-01-01

    The aim of this study was to compare the roentgenological and scintigraphic osseous changes in 25 resp. 18 patients with histiocytosis X and to analyse them. In particular, it was also interesting to discuss the divergent reports in the literature in respect of scintigraphic storage behaviour. In all patients examined before initiation of therapy (39 osseous foci) high activities were found scintigraphically. The extension of the scintigraphically active zone was much greater than the corresponding translucencies on the X-ray film. On the other hand, patients after therapy still showed foci on the X-ray film whereas the scan had already become inactive. This striking discrepancy between scan findings before and after therapy could be one of the reasons for divergent literature reports on this problem. (orig.) [de

  16. 3D tomographic imaging with the γ-eye planar scintigraphic gamma camera

    Science.gov (United States)

    Tunnicliffe, H.; Georgiou, M.; Loudos, G. K.; Simcox, A.; Tsoumpas, C.

    2017-11-01

    γ-eye is a desktop planar scintigraphic gamma camera (100 mm × 50 mm field of view) designed by BET Solutions as an affordable tool for dynamic, whole body, small-animal imaging. This investigation tests the viability of using γ-eye for the collection of tomographic data for 3D SPECT reconstruction. Two software packages, QSPECT and STIR (software for tomographic image reconstruction), have been compared. Reconstructions have been performed using QSPECT’s implementation of the OSEM algorithm and STIR’s OSMAPOSL (Ordered Subset Maximum A Posteriori One Step Late) and OSSPS (Ordered Subsets Separable Paraboloidal Surrogate) algorithms. Reconstructed images of phantom and mouse data have been assessed in terms of spatial resolution, sensitivity to varying activity levels and uniformity. The effect of varying the number of iterations, the voxel size (1.25 mm default voxel size reduced to 0.625 mm and 0.3125 mm), the point spread function correction and the weight of prior terms were explored. While QSPECT demonstrated faster reconstructions, STIR outperformed it in terms of resolution (as low as 1 mm versus 3 mm), particularly when smaller voxel sizes were used, and in terms of uniformity, particularly when prior terms were used. Little difference in terms of sensitivity was seen throughout.

  17. Scintigraphic demonstration of tracheo-esophageal fistula

    International Nuclear Information System (INIS)

    Dunn, E.K.; Man, A.C.; Lin, K.J.; Kaufman, H.D.; Solomon, N.A.

    1983-01-01

    A tracheo-esophageal fistula, developed following radiotherapy for an esophageal carcinoma, was vividly demonstrated by radionuclide imaging. The abnormality was later confirmed by a barium esophagram and endoscopic examinations. The scintigraphic procedure, making use of a Tc-99m sulfur colloid swallow, appears to be a simple alternative method use of a Tc-99m sulfur colloid swallow, appears to be a simple alternative method that may be clinically useful for the diagnosis of such a condition

  18. Experience based on 60 observations of scintigraphic bone exploration using pyrophosphates

    International Nuclear Information System (INIS)

    Mienville, J.-C.

    1975-01-01

    5 to 15 millicuries of technetium 99m-labelled pyrophosphates are injected intraveinously. 3 to 5 hours later, when the blood activity has dropped, the bone uptake is sufficient to give a good scintigraphic image of the skeleton. The skeleton may be explored one segment at a time, using a scanning scintigraph or a scintillation camera, or the whole skeleton front and back may be examined much more quickly with a 'whole-body' device. A study of 60 observations shows the large number of hyperfixations revealed by isotopic explorations in rheumatological diseases. A hyperfixation was observed in almost all bone localities of osteophilic cancers, osteonecrosis, Paget's disease, infections osteo-arthritis and algoneurodystrophy. On the other hand the isotopic test was found to be negative or inefficient in arthroses, osteoporosis and local bone manifestations of Kahler's or Hodgkin's disease. Finally inflammatory arthritis was detectable by scintigraphy in about half the cases studied. In reality a hyperfixation reflects a local rise in the metabolic activity of the bone at the moment of the examination. As a result the scintigraphic images lack specificity. This factor must therefore be accounted for in the patient's records and isotopic results compared with those of clinical and para-clinical examinations [fr

  19. Scintigraphic evaluation of Zenker's diverticulum

    Energy Technology Data Exchange (ETDEWEB)

    Valenza, Venanzio; Perotti, Germano; Di Giuda, Daniela [Institute of Nuclear Medicine, Policlinico A. Gemelli, Catholic University of Sacred Heart, Largo Gemelli 8, 00168, Rome (Italy); Castrucci, Gioacchino [Department of Surgery, Bel Colle Hospital, Viterbo (Italy); Celi, Giuseppe; Restaino, Gennaro [Institute of Radiology, Catholic University of Sacred Heart, Rome (Italy)

    2003-12-01

    Zenker's diverticulum (ZD) is a rare pathology, with a prevalence of between 0.01% and 0.11%. Definitive diagnosis of ZD can be accomplished by contrast radiographic examination (barium oesophagogram, BE); oesophageal manometry (ME) is recommended mainly for those patients suffering from dysphagia and/or gastro-oesophageal reflux. The aims of the present study were to assess whether oropharyngo-oesophageal scintigraphy (OPES) is able (a) to visualise ZD and (2) to demonstrate the corresponding alteration in the swallowing phases. We studied 16 patients (nine male, seven female, mean age 67.4 years), and 17 healthy volunteers (ten male, seven female, mean age 53 years) as a control group. All the patients underwent ME, BE and OPES. Nine patients underwent surgery and six of them were re-evaluated after 6 months. We administered 10 ml of water with 37 MBq of technetium-99m colloid through a straw, acquiring 480 sequential images (0.125 s/frame for a total of 60 s) with the patient standing in front of the gamma camera in the 80 right anterior oblique position. Two static images were performed at the end of the dynamic phase, before and after ingestion of 100 ml of unlabelled water to evaluate the presence of inflammation (persistence of radioactivity in the diverticulum or oesophagus). Study of the sequential scintigraphic images and time-activity curves permitted both qualitative (diverticulum visualisation, multiple deglutitions, reflux, presence of inflammation) and quantitative analyses [oral, pharyngeal and oesophageal transit times and retention indexes, tracheal aspiration percentage] of swallowing disorders. OPES showed a good correlation with the results of other diagnostic techniques usually performed in patients with this pathology, and especially with ME in the evaluation of oropharyngeal phase disorders. Furthermore, OPES is a sensitive and simple technique that is well tolerated and entails a low irradiation dose for patients. (orig.)

  20. Scintigraphic supervision of osteitis

    International Nuclear Information System (INIS)

    Manigault, L.; Sureau, B.; Wioland, M.; Perez, R.

    1975-01-01

    On the assumption that isotopic examinations of the bone metabolism and especially the scintigraphic method could give valuable results in the observation of osteitis patients treated with antibiotics, four cases of this disease were selected and followed regularly every three or four months for at least a year. Several bone scintigraphs were carried out with a scintillation camera after intraveinous injection of technetium-labelled pyrophosphate and the hyperfixation variations of the osteitis centre are given as a function of time. It is shown that bone scintigraphy gives an exact picture of the dimensions and morphology of lesions caused by an osteitis centre and above all, if repeated, enables the development of the infected region to be estimated. It seems that the healing of osteitis can be judged from scintigraphic evidence. Scintigraphy may be considered as a means to check the efficiency of an antibiotic treatment [fr

  1. 3D segmentation of scintigraphic images with validation on realistic GATE simulations

    International Nuclear Information System (INIS)

    Burg, Samuel

    2011-01-01

    The objective of this thesis was to propose a new 3D segmentation method for scintigraphic imaging. The first part of the work was to simulate 3D volumes with known ground truth in order to validate a segmentation method over other. Monte-Carlo simulations were performed using the GATE software (Geant4 Application for Emission Tomography). For this, we characterized and modeled the gamma camera 'γ Imager' Biospace"T"M by comparing each measurement from a simulated acquisition to his real equivalent. The 'low level' segmentation tool that we have developed is based on a modeling of the levels of the image by probabilistic mixtures. Parameters estimation is done by an SEM algorithm (Stochastic Expectation Maximization). The 3D volume segmentation is achieved by an ICM algorithm (Iterative Conditional Mode). We compared the segmentation based on Gaussian and Poisson mixtures to segmentation by thresholding on the simulated volumes. This showed the relevance of the segmentations obtained using probabilistic mixtures, especially those obtained with Poisson mixtures. Those one has been used to segment real "1"8FDG PET images of the brain and to compute descriptive statistics of the different tissues. In order to obtain a 'high level' segmentation method and find anatomical structures (necrotic part or active part of a tumor, for example), we proposed a process based on the point processes formalism. A feasibility study has yielded very encouraging results. (author) [fr

  2. Targeting of macrophages for the scintigraphic evaluation of inflammatory lesions in a model of radio-induced inflammation in pigs

    International Nuclear Information System (INIS)

    Hoffschir, D.; Daburon, F.; Normier, G.; Binz, H.; Le Pape, A.

    1991-01-01

    For a new scintigraphic strategy based on the targeting of macrophages recruited by inflammatory lesions, a specific ligand able to interact with these cells both in vitro and in vivo has been developed. J001 is a 34 KDa acylated peptidopoly 1-3 galactoside isolated from proteoglycans of a non pathogenic strain of klebsiella. When labelled with 99mTc then administrated by aerosol, this agent has been demonstrated to be a potent tool for the scintigraphic imaging of inflammatory lymph nodes in experimental berylliosis and in patients with sarcoidosis, lung tumors and ganglionic metastases. An experimental model was developed in pigs using an acute and localized muscular γ irradiation in the limb and skin resection to prevent ulceration. Dynamic imaging was performed during two hours after intravenous injection of 1 mg J001 labelled with 370 MBq 99mTc in the presence of 0.125 mg stannous fluoride. The perfusion of the lesions was evaluated from scintigraphic data obtained both 15 min after IV injection of J001 or 99mTc 04-. The intensity of the fixation of J001 was quantified 2 hours after injection and expressed as a scintigraphic ratio: R2h = cpm in lesion / cpm in a defined healthy area in the same limb. After induction of irradiation, scintigraphic ratios exhibited a progressive increase to reach a maximum (R2h = 3.6) after 3 months. Then, they decreased to recover a normal value about 6 months after irradiation. At that time, histological controls and clinical observations exhibited a significant decrease in inflammatory reaction, macrophages recruitment and apparition of fibrosis. J001 fixation was very sensitive to corticosteroids that resulted in a complete clearing of the scintigraphic images 12 to 24 hours after treatment. Two weeks were then required for a complete recovery of the inflammatory reaction and J001 fixation. So, targeting of macrophages with J001 should offer a sensitive and specific tool for the scintigraphic assessment of inflammation and

  3. Evolution of scintigraphic renal lesions in children after an episode of acute pyelonephritis

    International Nuclear Information System (INIS)

    Donoso, Gilda; Lagos, Elizabeth; Rosati, Pia; Hevia, Pilar; Cuevas, Karen; Lobo, Gabriel; Perez, Andres; Gutierrez, Daniela

    2012-01-01

    Background: Abnormal Dimercaptosuccinic acid (DMSA) renal scintigraphy performed six months after an acute pyelonephritis (AP) is generally interpreted as scarring. Aim: To perform a follow up of childhood patients showing scintigraphic renal lesions during the acute phase of pyelonephritis (within 7 days from the beginning of fever). Material and Methods: A scintigraphic control was carried out at 5-7 months and, in case of persistent lesions, an additional late scintigraphy at 10-13 months. All patients were followed clinically for one year and those with a relapse of urinary tract infection were excluded from the study. Results: Eighty five patients with a median age of 8 months were included. Among these, the first scintigraphic control was normal in 59 (69%) and abnormal in 26 patients (31%). In five of these 26 patients (5/26:19%-5/85:6%), a considerable regression of the lesions was obvious on the early control, and normalized completely on the late control. When expressing the results in kidney units, 107 showed lesions during the acute phase of infection; 69% was normal at the early control. Thirty three showed lesions persisting at the early control (31%) and 7 out of these 33 (21%) became normal on the late control (7/107: 7%). In total, 25% of the children included in the study (24% of the kidney units) remained with renal sequelae one year after the initial episode of AP. Conclusions: The persistence of scintigraphic lesions six months after an episode of AP, does not necessarily correspond to permanent scars, since normalization can sometimes be observed on late controls

  4. Unusual and subtle scintigraphic findings in the evaluation of the battered child

    International Nuclear Information System (INIS)

    Howard, J.L.; Barron, B.J.; Smith, G.G.

    1988-01-01

    Nuclear medicine imaging plays a key role in the evaluation of skeletal trauma. Recent findings in our department show that diagnoses other than skeletal trauma are often identified by means of subtle and unusual scintigraphic findings. The subject material will place strong emphasis on the less mentioned but often more important visceral and intracranial injury. Specific scintigraphic abnormalities to be demonstrated, with appropriate correlative radiographs, include (1) visceral and soft tissue (eg, duodenal hematoma, splenic laceration, renal contusion, hepatic hematoma, rhabdomyolysis and soft-tissue hematoma); (2) cranial (eg, intracranial bleeding, edema, and infarct, cephalohematoma, skull fracture, and widening of sutures; and (3) skeletal (various subtle abnormalities)

  5. An unusual scintigraphic pattern in sickle cell patients

    International Nuclear Information System (INIS)

    Glaser, A.M.; Chen, D.C.P.; Siegel, M.E.; Norris, S.L.; Haywood, L.J.

    1989-01-01

    We reviewed the nuclear medicine files of all patients enrolled in the sickle cell disease clinic who had had scans performed within the previous 5 years. We specifically looked for patterns of tracer uptake in these scans that would correlate with the severe anemia and consequent bone marrow hyperactivity of sickle cell patients. Thirty-three patients were included (21 men and 12 women) with a mean age of 26.8 years (range 17-48 years). The appearance of each of these patients' most recent scans was examined in the areas of the distal femurs, the proximal tibias and the distal tibias; a distinct triangular shaped pattern of increased activity was identified in these areas in a majority of patients. Thirty-three patients without sickle cell disease served as age-matched controls. This pattern was seen in 65.1% (95 out of 146 images) of the sickle cell patients' delayed images and 80.4% (82 out of 102 images) of their blood pool images. In contrast, the control patients demonstrated the triangular pattern in none of their blood pool studies (0%) and only 10.9% of their delayed bone images (P<0.001). The mean age of sickle cell patients with this pattern is 25.6 years which was significantly lower than that of those without this pattern (mean=37.5 years, P<0.05). Given the high prevalence of this unique scintigraphic pattern in a group of patients with known accelerated bone marrow function, these findings may be scintigraphic evidence of bone marrow expansion. The patient's age appears to be an important factor in visualization of this pattern. (orig.)

  6. Scintigraphic And Ultrasonic Determinations of Thyroid Volume

    International Nuclear Information System (INIS)

    Sarsono; Ismanto; Kunto, W; Hayati, N; Irma, S H

    1996-01-01

    A study has been done on the determination of thyroid volume by scintigraphic method in comparison to ultrasonographic technique, which involved a healthy woman volunteer, 5 women patients and a man patient with thyroid diseases. Scintigraphic examination upon the patient's thyroid was performed using a gamma camera 20 minutes following the injection of 55.5 Mbq (1.5 mCi) Tc-99m pertechnetate. A computer, with a dedicated program, coupled to the gamma camera was employed in the calculation of thyroid volume based on the scintigraphic data. Subsequent to the scintigraphic study, ultrasonographic determination of thyroid volume was then carried out. Correlation test that was applied to the outcome of the two methods of thyroid volume determination resulted in an excellent coefficient of correlation, R, which was 0.99. This showed a very good correlation between these two different techniques of thyroid volume determination

  7. Scintigraphic detection of regional disruption of adrenergic neurons in the heart

    International Nuclear Information System (INIS)

    Sisson, J.C.; Lynch, J.J.; Johnson, J.; Jaques, S. Jr.; Wu, D.; Bolgos, G.; Lucchesi, B.R.; Wieland, D.M.

    1988-01-01

    Experiments were designed to detect regional disruptions of adrenergic neurons in the hearts of living dogs. The neuron disruption was achieved by the application of phenol to the epicardium of the left ventricle. Evidence for denervation was the reduction in endogenous norepinephrine (NE) concentrations in the myocardium beneath the region of phenol treatment and toward the apex. Radiolabeled meta-iodobenzylguanidine (MIBG) acts as an analog of NE and as such is concentrated in adrenergic nerve terminals. Following phenol application, MIBG labeled with 125 I was found, 20 hours after injection, to be distributed within myocardium in patterns comparable to those of NE. However, left stellectomy did not alter the distributions of NE or 125 I-MIBG in the myocardium and apparently did not disrupt adrenergic innervation. MIBG labeled with 123 I enabled scintigraphic images of heart neurons in the living dog 3 and 20 hours after injection; these images portrayed the regions of adrenergic neuron disruption caused by phenol treatment. Concentrations of thallium-201 depicted on scintigraphic image and of triphenyltetrazolium observed on in vitro staining demonstrated no myocardial injury. Thus, scintigraphy with 123 I-MIBG will display regional adrenergic denervations in the heart

  8. Three-Phase Bone Scintigraphic Diagnosis of Acute Transient Synovitis

    International Nuclear Information System (INIS)

    Chung, Soo Kyo; Lee, Myung Hee; Kim, Choon Yul; Bahk, Yong Whee

    1985-01-01

    Acute transient synovitis of the hip presents clinically pain and limping. But in the majority of the cases, definite positive findings are not manifest in roentgenogram in its early phase. However radionuclide bone imaging combines with the assessment of vascularization and bone tracer uptake is of great value in solving this diagnostic problem. The materials for this study consisted of 29 children with acute transient synovitis of the hip, characterized by symptoms and physical signs of an arthritis, negative X-ray findings and disappearance of all symptoms and signs within a short period of time. They were twenty males and 9 females and age ranged from 1 to 12 years. We took pelvic roentgenogram in AP and frog-leg views. After intravenous bolus injection of 10 to 15 mCi of 99m Tc-methylene diphosphonate, 24 sequential image of the pelvis was taken at 2-second interval for blood flow study. The scintigrams were made using a gamma camera with high resolution parallel hole collimator. Blood pool imaging was obtained at 2 minutes after tracer administration. After 3 hours, static images were taken and then close-up image of the hip using pin-hole collimator was followed. The results were as follows: 1) Bone scintigram was much more sensitive than conventional roentgenogram in diagnosis of acute transient synovitis of the hip. 2) Three-phase imagings showed increased vascular activities in blood pool scintigrams in 96%. 3) Pin-hole imaging showed increased tracer uptake in the regional bones of the hip, particularly in the medial aspect of femoral head and acetabulum. 4) We confirmed that three-phase imaging reinforced with pin-hale technique were very useful in diagnose of acute transient synovitis of the hip.

  9. Comparison of de-noising techniques of scintigraphic images; Comparaison de techniques de debruitage des images scintigraphiques

    Energy Technology Data Exchange (ETDEWEB)

    Kirkove, M.; Seret, A. [Liege Univ., Imagerie Medicale Experimentale, Institut de Physique (Belgium)

    2007-05-15

    Scintigraphic images are strongly affected by Poisson noise. This article presents the results of a comparison between de-noising methods for Poisson noise according to different criteria: the gain in signal-to-noise ratio, the preservation of resolution and contrast. and the visual quality. The wavelet techniques recently developed to de-noise Poisson noise limited images are divided into two groups based on: (1) the Haar representation. 1 (2) the transformation of Poisson noise into white Gaussian noise by the Haar-Fisz transform followed by a de-noising. In this study, three variants of the first group and three variants of the second. including the adaptative Wiener filter, four types of wavelet thresholding and the Bayesian method of Pizurica were compared to Metz and Hanning filters and to Shine, a systematic noise elimination process. All these methods, except Shine, are parametric. For each of them, ranges of optimal values for the parameters were highlighted as a function of the aforementioned criteria. The intersection of ranges for the wavelet methods without thresholding was empty, and these methods were therefore not further compared quantitatively. The thresholding techniques and Shine gave the best results in resolution and contrast. The largest improvement in signal-to-noise ratio was obtained by the filters. Ideally, these filters should be accurately defined for each image. This is difficult in the clinical context. Moreover. they generate oscillation artefacts. In addition, the wavelet techniques did not bring significant improvements, and are rather slow. Therefore, Shine, which is fast and works automatically, appears to be an interesting alternative. (authors)

  10. Modeling and analysis of dynamic scintigraphic data for measurement of cardiac perfusion and performance

    International Nuclear Information System (INIS)

    Twieg, D.B.

    1977-01-01

    Clinical scintigraphy is the technique of imaging the distributions of gamma-ray-emitting tracers within a patient's body. The increasingly popular small nuclear medicine computer has greatly facilitated the use of mathematical models for interpretation of scintigraphic data, and has made it possible for the clinician and the researcher to extract from the scintigraphic data information not otherwise available. The purpose of this work was to investigate several models used in dynamic scintigraphic studies of the heart. The Xenon washout method of measuring myocardial perfusion is discussed. The use of single-compartment, multi-compartment, and noncompartmental models are critically examined, and the influence of multiexponential components on monoexponential fits for perfusion measurement from Xenon washouts is investigated. A model of cardiac pump function is developed which allows for incompetent valves at the input and output of the ventricular chamber. An iterative method is used in conjunction with the model to estimate forward and regurgitant flows from simulated noisy scintigraphic data and from patient data. Unlike previously available methods, the method presented here was developed to allow noninvasive determination of both mitral and aortic regurgitation. Simulation results were successful, and preliminary studies in a few patients were encouraging. An investigation is presented into the relationship between the count-volume and geometric scintigraphic methods of estimating left ventricular ejection fraction, an important index of the contractile state of the myocardial muscle. A bias due to failure to account for the effects of Poisson noise was found in one popular method for ejection measurement

  11. Scintigraphic diagnosis of the gastro-esophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Pfluecke, F.; Krueger, M.; Reinke, R.; Groth, P. (Rostock Univ. (German Democratic Republic). Radiologische Klinik)

    1982-09-01

    Patients with peptic esophagitis or typical complaints with respect to reflux without esophagitis and control persons (n = 68) were comparatively examined for gastroesophageal reflux by means of scintigraphy (after administration of test solutions labelled with /sup 99m/Tc-DTPA or after intravenous application of /sup 99m/Tc-pertechnetate) and by means of continuous intraesophageal p/sub H/ measurement. The scintigraphic test of the reflux was successful for very few patients only with reflux disease and a reflux detectable by measuring the p/sub H/. The application of pentagastrin failed in improving the scintigraphic detection of the reflux. The cause of the unsuccessful scintigraphic evidence for the majority of the reflux patients seems to be the relatively small reflux volume.

  12. Scintigraphic diagnosis of the gastro-esophageal reflux

    International Nuclear Information System (INIS)

    Pfluecke, F.; Krueger, M.; Reinke, R.; Groth, P.

    1982-01-01

    Patients with peptic esophagitis or typical complaints with respect to reflux without esophagitis and control persons (n = 68) were comparatively examined for gastroesophageal reflux by means of scintigraphy (after administration of test solutions labelled with /sup 99m/Tc-DTPA or after intravenous application of /sup 99m/Tc-pertechnetate) and by means of continuous intraesophageal p/sub H/ measurement. The scintigraphic test of the reflux was successful for very few patients only with reflux disease and a reflux detectable by measuring the p/sub H/. The application of pentagastrin failed in improving the scintigraphic detection of the reflux. The cause of the unsuccessful scintigraphic evidence for the majority of the reflux patients seems to be the relatively small reflux volume

  13. Scintigraphic defecography in various anorectal disorders

    International Nuclear Information System (INIS)

    Ishii, Yuji; Oya, Masatoshi; Ishikawa, Hiroshi

    1998-01-01

    Scintigraphic defecography was performed using 99m Tc-DATA to quantitatively evaluate defecation in 26 patients after low anterior resection of rectal cancer (LAP-group), 19 patients with chronic constipation (C-group), 11 patients with miscellaneous anal symptoms (AN-group), and 12 normal volunteers. After introducing semi-solid artificial stool containing 99m Tc-DTPA into the rectum, right lateral images of the anorectum were serially obtained during voluntary evacuation. From the time activity curve of the whole rectum, the half emptying time (T1/2) and the percentage of rectal evacuation (evacuation ratio) were calculated. Three abnormal patterns were identified: the flat type in which a temporary elevation of the RI activity, usually recorded in normal volunteers at the beginning of evacuation, was not recorded; the slow type in which T1/2 was over 20 seconds; and the poor evacuation type in which evacuation ratio was less than 80%. In the LAR-group, all the patients having very low anastomosis showed abnormal patterns irrespective of the type of reconstruction (straight or colonic J-pouch). In the C-group, 10 patients who had either slow pattern or poor evacuation pattern were suggested to have outlet obstruction. In the AN-group, the evacuation pattern differed from patient to patient. Scintigraphic defecography is useful in identifying abnormal evacuation in various anorectal disorders. (author)

  14. Scintigraphic defecography in various anorectal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Yuji; Oya, Masatoshi; Ishikawa, Hiroshi [Dokkyo Univ., School of Medicine, Saitama (Japan). Koshigaya Hospital

    1998-04-01

    Scintigraphic defecography was performed using {sup 99m}Tc-DATA to quantitatively evaluate defecation in 26 patients after low anterior resection of rectal cancer (LAP-group), 19 patients with chronic constipation (C-group), 11 patients with miscellaneous anal symptoms (AN-group), and 12 normal volunteers. After introducing semi-solid artificial stool containing {sup 99m}Tc-DTPA into the rectum, right lateral images of the anorectum were serially obtained during voluntary evacuation. From the time activity curve of the whole rectum, the half emptying time (T1/2) and the percentage of rectal evacuation (evacuation ratio) were calculated. Three abnormal patterns were identified: the flat type in which a temporary elevation of the RI activity, usually recorded in normal volunteers at the beginning of evacuation, was not recorded; the slow type in which T1/2 was over 20 seconds; and the poor evacuation type in which evacuation ratio was less than 80%. In the LAR-group, all the patients having very low anastomosis showed abnormal patterns irrespective of the type of reconstruction (straight or colonic J-pouch). In the C-group, 10 patients who had either slow pattern or poor evacuation pattern were suggested to have outlet obstruction. In the AN-group, the evacuation pattern differed from patient to patient. Scintigraphic defecography is useful in identifying abnormal evacuation in various anorectal disorders. (author)

  15. In vitro radionuclide therapy and in vivo scintigraphic imaging of alpha fetoprotein producing hepatocellular carcinoma by targeted sodium iodide symporter gene expression

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kwang Il; Lee, Yong Jin; Lee, Tae Sup; Song, Inho; Cheon, Gi Jeong; Lim, Sang Moo; Kang, Joo Hyun [Korea Institute of Radiological and Medical and Medical Sciences, Seoul (Korea, Republic of); Chung, June Key [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2012-03-15

    This study aimed to develop a gene expression targeting method for specific imaging and therapy of alpha fetoprotein (AFP) producing hepatocellular carcinoma (HCC) cells, using an adenovirus vector containing the human sodium/iodide symporter (hNIS) gene driven by an AFP enhancer/promoter. The recombinant adenovirus vector, AdAFPhNIS (containing the hNIS gene driven by human AFP enhancer/promoter) was prepared. After in vitro infection by the adenovirus, hNIS gene expression in AFP producing cells and in AFP nonproducing cells was investigated using {sup 125}I uptake assay and semi quantitative reverse transcription polymerase chain reaction (RT-PCR). The killing effect of {sup 131}I vitro clonogenic assay. In addition, tumor bearing mice were intravenously injected with the adenovirus, and scintigraphic images were obtained. The expression of hNIS was efficiently demonstrated by {sup 125}I uptake assay in AFP producing cells, but not in AFP nonproducing cells. AFP producing HCC targeted gene expression was confirmed at the mRNA level. Furthermore, in vitro clonogenic assay showed that hNIS gene expression induced by AdAFPhNIS infection in AFP producing cells caused more sensitivity to {sup 131}I than that in AFP nonproducing cells. Injected intravenously in HuH-7 tumor xenografts mice by adenovirus, the functional hNIS gene expression was confirmed in tumor by in vivo scintigraphic imaging. An AFP producing HCC was targeted with an adenovirus vector containing the hNIS gene using the AFP enhancer/promoter in vitro and in vivo. These findings demonstrate that AFP producing HCC specific molecular imaging and radionuclide gene therapy are feasible using this recombinant adenovirus vector system.

  16. In vitro radionuclide therapy and in vivo scintigraphic imaging of alpha fetoprotein producing hepatocellular carcinoma by targeted sodium iodide symporter gene expression

    International Nuclear Information System (INIS)

    Kim, Kwang Il; Lee, Yong Jin; Lee, Tae Sup; Song, Inho; Cheon, Gi Jeong; Lim, Sang Moo; Kang, Joo Hyun; Chung, June Key

    2012-01-01

    This study aimed to develop a gene expression targeting method for specific imaging and therapy of alpha fetoprotein (AFP) producing hepatocellular carcinoma (HCC) cells, using an adenovirus vector containing the human sodium/iodide symporter (hNIS) gene driven by an AFP enhancer/promoter. The recombinant adenovirus vector, AdAFPhNIS (containing the hNIS gene driven by human AFP enhancer/promoter) was prepared. After in vitro infection by the adenovirus, hNIS gene expression in AFP producing cells and in AFP nonproducing cells was investigated using 125 I uptake assay and semi quantitative reverse transcription polymerase chain reaction (RT-PCR). The killing effect of 131 I vitro clonogenic assay. In addition, tumor bearing mice were intravenously injected with the adenovirus, and scintigraphic images were obtained. The expression of hNIS was efficiently demonstrated by 125 I uptake assay in AFP producing cells, but not in AFP nonproducing cells. AFP producing HCC targeted gene expression was confirmed at the mRNA level. Furthermore, in vitro clonogenic assay showed that hNIS gene expression induced by AdAFPhNIS infection in AFP producing cells caused more sensitivity to 131 I than that in AFP nonproducing cells. Injected intravenously in HuH-7 tumor xenografts mice by adenovirus, the functional hNIS gene expression was confirmed in tumor by in vivo scintigraphic imaging. An AFP producing HCC was targeted with an adenovirus vector containing the hNIS gene using the AFP enhancer/promoter in vitro and in vivo. These findings demonstrate that AFP producing HCC specific molecular imaging and radionuclide gene therapy are feasible using this recombinant adenovirus vector system

  17. The use of 111In-labelled platelets for scintigraphic localization of gastrointestinal bleeding with special reference to occult bleeding

    International Nuclear Information System (INIS)

    Gjerloeff Schmidt, K.; Waever Rasmussen, J.; Grove, O.; Andersen, D.

    1986-01-01

    Gamma-camera imaging of the abdomen after injection of autologous 111 In-labelled platelets was applied for localization of gastrointestinal bleeding in a study of 22 patients. In 15 studies showing scintigraphic signs of bleeding, the clinical presentation included occult bleeding in 6, melaena in 4, and bloody stools in 5 patients. Scintigraphy could be done repeatedly for up to 1 week after a single tracer injection. The time interval between the injection and scintigraphic visualization of bleeding ranged from 10 min to 68 h, being longest in cases of occult bleeding. In most cases the scintigraphic findings were supported by other diagnostic modalities, including surgical removal of presumed sources of bleeding. In seven studies without scintigraphic signs of bleeding, a probable source of bleeding was identified by other means in one patient. The 111 In-platelet method seems to be a promising method for localization of gastrointestinal bleeding which may prove particularly useful in cases of occult or recurrent bleeding

  18. A “Proteoglycan Targeting Strategy” for the Scintigraphic Imaging and Monitoring of the Swarm Rat Chondrosarcoma Orthotopic Model

    Directory of Open Access Journals (Sweden)

    Caroline Peyrode

    2011-01-01

    Full Text Available Our lab developed 99mTc-NTP 15-5 radiotracer as targeting proteoglycans (PGs for the scintigraphic imaging of joint. This paper reports preclinical results of 99mTc-NTP 15-5 imaging of an orthotopic model of Swarm rat chondrosarcoma (SRC. 99mTc-NTP 15-5 imaging of SRC-bearing and sham-operated animals was performed and quantified at regular intervals after surgery and compared to bone scintigraphy and tumoural volume. Tumours were characterized by histology and PG assay. SRC exhibited a significant 99mTc-NTP 15-5 uptake at very early stage after implant (with tumour/muscle ratio of 1.61 ± 0.14, whereas no measurable tumour was evidenced. As tumour grew, mean tumour/muscle ratio was increased by 2.4, between the early and late stage of pathology. Bone scintigraphy failed to image chondrosarcoma, even at the later stage of study. 99mTc-NTP 15-5 imaging provided a suitable set of quantitative criteria for the in vivo characterization of chondrosarcoma behaviour in bone environment, useful for achieving a greater understanding of the pathology.

  19. Scintigraphic features of cirrhosis of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Bell, E; Biersack, H J; Altland, H; Albrecht, M; Winkler, C

    1980-09-01

    A retrospective study of 101 patients with histologically confirmed cirrhosis of the liver and portal hypertension was carried out in order to evaluate the accepted scintigraphic criteria. In only 20% were all the essential criteria present. The absence of generally accepted important scintigraphic signs does not exclude the diagnosis of cirrhosis of the liver. Specificity of liver scintigraphy in cirrhosis of the liver is fairly low, but sensitivity of the method is almost 100%.

  20. Scintigraphic evaluation of the sacroiliac joints in anklylosing spondylitis

    International Nuclear Information System (INIS)

    Schoerner, W.

    1980-01-01

    The sedimentation of sup(99m)Tc-phosphate complexes into the sacroiliac joints was investigated in 94 patients with loin pains and suspected of ankylosing spondylitis (SpA) and a control group of 96 healthy patients. The investigation yields the following results: 1. the visual evaluation of the scintigrams does not allow a reliable diagnosis and should be replaced by a semi-quantitative technique, 2. the index ISC/sacrum does remarkably depend on age, 3rd even in young patients the scintigraphic examination appears to be useful to alidate the clinical suspicion of sacroilictis which is in contradiction to literature, 4th with increasing SpA the scintigraphic detectability of changes in the ISG decreases. 5th the floriditily of the ISG process determines the scintigraphic detectability of the process of the disease, 6th the scintigraphic finding is unspecific. Inflammatory states of the disease of different genesis and degenerative processes in the ISG equally yield pathological index values. (orig./MG) [de

  1. Liver scintigraphic features associated with alcoholism

    International Nuclear Information System (INIS)

    Drum, D.E.; Beard, J.O.

    1978-01-01

    The relationships between scintigraphic features and clinical alcoholism were studied by review of 2406 liver scintiphotos. Two distinct patterns were significantly associated with alcoholism: heterogeneous distribution of radiocolloid in the liver, and jointly increased uptake of tracer by the spleen and vertebral bone marrow. A total of 13 overall patterns were found to distinguish, with considerable reliability, alcoholics from all other patients. This finding reflects the frequency with which alcohol abuse is associated with hepatic dysfunction in hospital patients. These observations indicate an important role for the nuclear medicine physician in detection of alcoholism among patients referred for liver-spleen imaging, and they form a basis for comparison with the diagnostic efficacy of other methods of evaluating diffuse liver diseases

  2. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    International Nuclear Information System (INIS)

    Hausmann, T.; Mueller-Schauenburg, W.; Goeke, M.; Luebeck, M.; Gratz, K.F.; Meier, P.; Manns, M.; Hundeshagen, H.

    1995-01-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  3. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Hausmann, T. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Mueller-Schauenburg, W. [Abt. Nuklearmedizin, Univ. Tuebingen (Germany); Goeke, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Luebeck, M. [Abt. Nuklearmedizin, Univ.-Krankenhaus Eppendorf, Hamburg (Germany); Gratz, K.F. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Meier, P. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Manns, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Hundeshagen, H. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany)

    1995-11-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  4. Scintigraphic pattern of small bowel bleeding

    International Nuclear Information System (INIS)

    Anshu Rajnish Sharma; Charan, S.; Silva, I.

    2004-01-01

    Introduction: Small intestine is the longest part of gastrointestinal tract. Intra-luminal haemorrhage occurring anywhere in its long and tortuous course is difficult to trace. It is relatively inaccessible to endoscopic evaluation. Upper GI endoscopy can see only up to distal duodenum, whereas colonoscope can view maximum of 30 centimeters of terminal ileum after negotiating the scope through ileo-caecal valve. Hence, localization of bleeding source from small bowel remains a difficult clinical problem. This group of patients can be evaluated with scintigraphy for localizing the site of bleeding before undergoing either angiography or surgery. To our best of knowledge, there is no study, which has utilized scintigraphy for evaluation of small bowel bleed exclusively. The present study has been designed to know the efficacy of 99mTc-RBC scintigraphy in detecting small bowel bleed and to know whether it can differentiate between jejunal and ileal bleeding ? Materials and methods: Thirteen patients presenting with lower gastrointestinal bleeding (malena) were enrolled for the study. In all cases, upper GI endoscopy (UGIE) was unremarkable. Colonoscopic examination was either negative or suspected bleeding occurring proximal to ileo-caecal valve. Thus, in these patients, it is presumed clinically that bleeding is originating from small bowel. Barium meal follow through (BMFT) studies, however, could not delineate any etiological lesion in these patients. There were 8 men and 5 women (mean age 48 years). All patients were anemic (Hb- 6 gm%) and mean 3 units of blood were transfused.These patients were subjected to Tc-99m labeled red blood cells scintigraphy (15 mci, in-vivo method) for localization of source of bleeding. The scintiscan was acquired in two phases. A first pass phase acquired at a rate of 2 seconds per frame for 60 seconds followed by acquisition of static abdominal images (500 K, 256 x 256 matrix) at 5 minutes intervals up to 90 minutes on LFOV gamma

  5. Pharyngeal transit time measured by scintigraphic and biomagnetic method

    International Nuclear Information System (INIS)

    Miquelin, C.A.; Braga, F.J.H.N.; Baffa, O.

    1996-01-01

    A comparative evaluation between scintigraphic and biomagnetic method to measure the pharyngeal transit is presented. Three volunteers have been studied. The aliment (yogurt) was labeled with 9 9 m Technetium for the scintigraphic test and with ferrite for the biomagnetic one. The preliminary results indicate a difference between the values obtained, probably due to the biomagnetic detector resolution

  6. Doubling time of liver metastase images

    International Nuclear Information System (INIS)

    Bittighoffer, Bernard.

    1975-01-01

    For our study, where clinical and scintigraphic observation seldom lasts more than two years and where measurable metastases always exceed 1 cm 3 , the exponential model was adopted and our results were all calculated with GERSTENBERG's formula which gives an apparent doubling time. The liver metastases were measured on the scintigraphic image obtained, a more or less sharply limited blank which makes for a first difficulty of judgement. Two magnascanner V type PICKER 5-inch crystal scintigraphs were used, giving three images simultaneously by a transcriber made up of a stylus and a light spot built into the detection system. The isotope used is colloidal gold ( 198 Au) phagocytized by the Kuepfferian reticulo-endothelial system. The doubling time for liver metastase scintigraphic images calculated for fifteen patients having undergone one or more isotopic checks after a first metastase image was discovered range from 10 to 103 days [fr

  7. Computer processing of dynamic scintigraphic studies

    International Nuclear Information System (INIS)

    Ullmann, V.

    1985-01-01

    The methods are discussed of the computer processing of dynamic scintigraphic studies which were developed, studied or implemented by the authors within research task no. 30-02-03 in nuclear medicine within the five year plan 1981 to 85. This was mainly the method of computer processing radionuclide angiography, phase radioventriculography, regional lung ventilation, dynamic sequential scintigraphy of kidneys and radionuclide uroflowmetry. The problems are discussed of the automatic definition of fields of interest, the methodology of absolute volumes of the heart chamber in radionuclide cardiology, the design and uses are described of the multipurpose dynamic phantom of heart activity for radionuclide angiocardiography and ventriculography developed within the said research task. All methods are documented with many figures showing typical clinical (normal and pathological) and phantom measurements. (V.U.)

  8. Scintigraphic measurement of the contractile activity of the gastric antrum using factor analysis

    International Nuclear Information System (INIS)

    Bergmann, H.; Hoebart, J.; Kugi, A.; Stacher, G.; Granser, G.V.

    1990-01-01

    The motor activity of the gastric antrum is difficult to record by manometric means and scintigraphic methods have proved unsatisfactory so far as no consistent relationship between antral contractile activity and gastric emptying rate could be detected. We investigated, using data recorded in 16 healthy human subjects after the ingestion of a semisolid standard meal, whether a newly developed method employing factor analysis would yield more meaningful and reproducible results. Factor analysis was applied to sequential scintigraphic images (3-s frame time) of gastric antrum. The computed factor images and the respective factor curves are representative of distinct dynamic structures of the antrum. From the more or less sinusoidal excursions of the factor curves, which exhibited the 3 cycles per minute frequency characteristic for the stomach, amplitude, frequency and propagation velocity of antral contractions can be calculated. The amplitudes of the factor curves were used to calculate a contraction index. This contraction index was found to be correlated significantly negatively with the gastric half-emptying time of the ingested meal. The employed factor analytical approach thus seems a promising tool to further investigate the role of antral contractility in the process of gastric emptying. (Authors)

  9. Quantitative and regional evaluation methods for lung scintigraphs

    International Nuclear Information System (INIS)

    Fichter, J.

    1982-01-01

    For the evaluation of perfusion lung scintigraphs with regard to the quantitative valuation and also with regard to the choice of the regions new criteria were presented. In addition to the usual methods of sectioning each lung lobe into upper, middle and lower level and the determination of the per cent activity share of the total activity the following values were established: the median of the activity distribution and the differences of the per cent counting rate as well as of the median of the corresponding regions of the right and left lung. The individual regions should describe the functional structures (lobe and segment structure). A corresponding computer program takes over the projection of lobe and segment regions in a simplified form onto the scintigraph with consideration of individual lung stretching. With the help of a clinical study on 60 patients and 18 control persons with 99mTc-MAA and 133 Xe-gas lung scintigraphs the following results could be determined: depending on the combination of the 32 parameters available for evaluation and the choice of regions between 4 and 20 of the 60 patients were falsely negatively classified and 1 to 2 of the 18 controls were falsely positive. The accuracy of the Tc-scintigraph proved to be better. All together using the best possible parameter combinations comparative results were attained. (TRV) [de

  10. Fast renal trapping of porcine Luteinizing Hormone (pLH shown by 123I-scintigraphic imaging in rats explains its short circulatory half-life

    Directory of Open Access Journals (Sweden)

    Locatelli Alain

    2003-10-01

    Full Text Available Abstract Background Sugar moieties of gonadotropins play no primary role in receptor binding but they strongly affect their circulatory half-life and consequently their in vivo biopotencies. In order to relate more precisely hepatic trapping of these glycoproteic hormones with their circulatory half-life, we undertook a comparative study of the distribution and elimination of porcine LH (pLH and equine CG (eCG which exhibit respectively a short and a long half-life. This was done first by following half-lives of pLH in piglets with hepatic portal circulation shunted or not. It was expected that such a shunt would enhance the short half-life of pLH. Subsequently, scintigraphic imaging of both 123I-pLH and 123I-eCG was performed in intact rats to compare their routes and rates of distribution and elimination. Methods Native pLH or eCG was injected to normal piglets and pLH was tested in liver-shunted anæsthetized piglet. Blood samples were recovered sequentially over one hour time and the hormone concentrations were determined by a specific ELISA method. Scintigraphic imaging of 123I-pLH and 123I-eCG was performed in rats using a OPTI-CGR gamma camera. Results In liver-shunted piglets, the half-life of pLH was found to be as short as in intact piglets (5 min. In the rat, the half-life of pLH was also found to be very short (3–6 min and 123I-pLH was found to accumulate in high quantity in less than 10 min post injection at the level of kidneys but not in the liver. 123I-eCG didn't accumulate in any organ in the rats during the first hour, plasma concentrations of this gonadotropin being still elevated (80% at this time. Conclusion In both the porcine and rat species, the liver is not responsible for the rapid elimination of pLH from the circulation compared to eCG. Our scintigraphic experiments suggest that the very short circulatory half-life of LH is due to rapid renal trapping.

  11. Scintigraphic instruments and techniques in nuclear medicine

    International Nuclear Information System (INIS)

    Bornand, B.; Soussaline, F.

    1977-03-01

    The development of new radiopharmaceuticals, cyclotron-produced radionuclides and improvement of detector, scanner and gamma camera characteristics have enable a remarkable recent progress in scintigraphic techniques for organ visualization and functional studies. Using a variety of techniques, positron cameras, section scanners, gamma holography, tomographic imaging appear to be playing an increasing important role. Data processing techniques, for example image processing and three dimensional reconstruction have significantly increased their impact. The principal research work and advances in technique achieved up to 1972 are summarized and the subjects which have been further exploited are outlined. The main section comprises references and abstracts of articles from scientific journals and conference proceedings (191 articles and 221 papers mentioned) for the period 1972-1975 to illustrate advances in this domain: Excerpta Medica (Nuclear Medicine) Abstract Journals and Nuclear Science Abstracts (1972-1975) were used as abstracting publications. This survey is completed with an index of authors and subject-matters. Eleven thesis are mentionned in an appendix [fr

  12. Avascularity of the femoral head following intracapsular fracture: a comparative scintigraphic and bioptic study

    Energy Technology Data Exchange (ETDEWEB)

    Hoilund-Carlsen, P F; Widding, A; Uhrenholdt, A; Christoffersen, P; Grieff, J [Copenhagen Univ. (Denmark)

    1980-03-01

    Bioptic and scintigraphic methods of diagnosing avascular necrosis of the femoral head following intracapsular fracture of the femoral neck were compared. During operative treatment of patients, biospy samples of bone marrow were taken from the femoral head about 2 hours after the intravenous injection of sup(99m)Tc-Sn-pyrophosphate; histological examination of the biopsies were also performed. Scintigrams of the femoral head using sup(99m)Tc-pyrophosphate were performed 2 days, 7 days and 6 weeks post-operatively. The biopsies confirmed no morphological changes being apparent in the first few days. The biopsy samples indicated two groups of patients with either high or low activity in the femoral head. However, it was concluded that the use of bone-seeking radionuclides with this technique might be more reliable. Scintigraphic trends divided the patients into three groups, one with persistently normal, another with varying, and a third with decreased activity in the femoral head. It was concluded that very early scintigraphy is probably not the method of choice since the images were often difficult to interpret. For the present, assessment of the viability of the femoral head should rest upon scintigraphic examinations performed about 6 weeks or 3 months after the injury.

  13. 201Tl scintigraphic evaluation of tumor mass and viability of bone and soft-tissue tumors

    International Nuclear Information System (INIS)

    Tsuda, Takatoshi; Kubota, Masahiro; Yoshida, Satoru; Shibata, Masahito; Wakabayashi, Jun-ichi; Obata, Hiroyuki; Matsuyama, Toshikatsu; Usui, Masamichi; Ishii, Sei-ichi.

    1994-01-01

    To characterize 201 Tl uptake in patients with bone and soft-tissue tumor, we studied 49 patients with surgically proven tumors and one patient with a tumor diagnosed arteriographically. In 37 of our 50 patients, the tumor was evaluated with 201 Tl and arteriography. Moreover, in 14 of patients with pre-operative chemotherapy, pathologic changes were graded on the basis of percent tumor necrosis as defined histologically. The percent tumor necrosis histologically was compared with changes in the scintigraphic and conventional angiographic studies. Radiologic comparisons demonstrated a high degree of correlation with images of 201 Tl and both arterial and blood pool phase of 99m Tc-HMDP. Ninety-six percent of 28 malignant tumors had positive 201 Tl uptake. None of the patients showed any thallium accumulation in the soft tissues or skeleton adjacent to the lesion. Activity of 201 Tl was mainly dependent upon a tumor blood flow and a vascular density. In of 14 cases with the preoperative chemotherapeutic treatment, 201 Tl scintigraphic changes showed concordance with % tumor necrosis. Thallium-201 was superior to 99m Tc-HMDP in predicting tumor response to chemotherapy. Interestingly, delayed images of 99m Tc-HMDP of 5 responders with >90% tumor necrosis showed decreased uptake in the adjacent bone to the tumor mass lesions. It seems to be quite all right to consider that a major determinant of 201 Tl uptake is intratumoral angiogenecity, which is closely connected with tumor viability. Therefore, 201 Tl is a sensitive radiopharmaceutical for detection of vascular rich bone and soft-tissue tumors, and appears to be a simple and an accurate test for evaluating the response to specific therapeutic regimens of malignant bone and soft-tissue tumors. (author)

  14. Three-phase scintigraphy in the Sudeck syndrome

    International Nuclear Information System (INIS)

    Koppers, B.

    1982-01-01

    37 patients with clinically and radiologically proved reflex sympathetic dystrophy syndrome were scintigraphied by sup(99)mTc-MDP (three-phase scintigraphy). In 87% of the examinations (all three-phases) an increased tracer accumulation in the region of the affected limb could be seen scintigraphically. The majority of the positive results (92% resp. 87%) were found in the intervall phase (phase II) and the late phase (phase III) of the scintigraphic examinations. - We recommend a staging of the increase of the tracer accumulation when examing the reflex sympathetic dystrophy syndrome. This staging doesn't significantly correlate with the familiar clinical and radiological stagings. However it may be useful when assessing the course of the syndrome. - Increased tracer accumulations could be observed in the case of clinically, radiologically and scintigraphically manifest reflex sympathetic dystrophy syndrome in the region of the foot, frequently in the ipsilateral knee region, rarely in the ipsilateral hip joint region, although clinically the syndrome could not be observed in these regions. (orig.) [de

  15. 99mTc-ceftriaxone, as a targeting radiopharmaceutical for scintigraphic imaging of infectious foci due to Staphylococcus aureus in mouse model

    International Nuclear Information System (INIS)

    Akram Fazli; Mojtaba Salouti; Mohammad Mazidi

    2013-01-01

    99m Tc-labeled antibiotics have opened an exciting field of research in infectious diseases diagnosis. Direct labeling of ceftriaxone with 99mTc was carried out using the various amounts of ceftriaxone and SnCl 2 ·2H 2 O at different pH and incubation time intervals to find the highest radiochemistry efficiency with high stability at room temperature and human blood serum. ITLC-SG and HPLC were performed to measure the radiochemical purity of the conjugate. The binding study showed 45 % specific binding to Staphylococcus aureus. The biodistribution study and scintigraphic imaging showed the localization of 99m Tc-ceftriaxone at the site of infection in comparison with normal and inflamed muscles with high sensitivity and specificity in mouse model. The results showed that 99m Tc-ceftriaxone is a promising candidate as a targeting radiopharmaceutical for Staphylococcal infection imaging in humans which needs further investigations. (author)

  16. Gastroesophageal reflux disease. Scintigraphic, endoscopic and histologic considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kault, B.; Halvorsen, T.; Petersen, H.; Grette, K.; Myrvold, H.E.

    1986-01-01

    Radionucleotide scintigraphy and esophagoscopy with biopsy were carried out in 101 patients with symptoms strongly suggestive of gastroesophageal reflux (GER) disease. GER was visualized by scintigraphy in 86.1% of the patients. Endoscopic and histologic esophagitis were found in 68.1% and 58.4% of the patients, respectively, whereas both examinations taken together showed evidence of esophagitis in 82%. Histologic evidence of esophagitis was found in nearly all patients with severe endoscopic changes, and in 43.7% of the patients with no endoscopic abnormality. Scintigraphic reflux was demonstrated more frequently in the patients with severe endoscopic esophagitis (97.5%) than in those with no or only mild endoscopic changes (78.6%). Scintigraphic reflux was found in 91.5% and 78.5% of the patients with and without histologic evidence of esophagitis. 15 of the 18 patients (83.3%) without endoscopic and histologic abnormalities in the esophagus had scintigraphic evidence of reflux. The present study strongly supports the clinical significance of scintigraphy in GER disease and confirms that esophageal biopsy specimens increase the sensitivity of endoscopic evaluation. 31 refs.

  17. Bone stress: a radionuclide imaging perspective

    International Nuclear Information System (INIS)

    Roub, L.W.; Gumerman, L.W.; Hanley, E.N. Jr.; Clark, M.W.; Goodman, M.; Herbert, D.L.

    1979-01-01

    Thirty-five college athletes with lower leg pain underwent radiography and radionuclide studies to rule out a stress fracture. Their asymptomatic extremities and 13 pain-free athletes served as controls. Four main patterns were observed: (a) sharply marginated scintigraphic abnormalities and positive radiographs; (b) sharply marginated scintigraphic abnormalities and negatives radiographs; (c) ill-defined scintigraphic abnormalities and negative radiographs; and (d) negative radionuclide images and negative radiographs. Since the patients with the first two patterns were otherwise identical medically, the authors feel that this scintigraphic appearance is characterisic of bone stress in the appropriate clinical setting, regardless of the radiographic findings. A schema is proposed to explain the occurrence of positive radionuclide images and negative radiographs in the same patient, using a broad conceptual approach to the problem of bone stress

  18. Scintigraphic presentation of hip joint synovial chondromatosis

    Energy Technology Data Exchange (ETDEWEB)

    Zwas, S T; Friedman, B; Nerubay, J

    1988-09-01

    A case of hip joint synovial chondromatosis with an unusual scintigraphic pattern is described. This pattern was suggestive of a hip joint destructive reactive articular process or late manifestations of avascular necrosis of the femoral head. Concurrent radiographs were normal, as were laboratory investigations. Follow-up radiographs six months later showed radiolucencies and erosive bone changes in the diseased joint. Surgical and histopathological findings revealed well developed hip synovial chondromatosis (HSC) with thickened synovium and large, loose, cartilaginous bodies occupying and widening the tightened joint space, with destructive secondary juxta articular pressure and bone erosions. This and other scintigraphic patterns in HSC, and the differential diagnosis of the findings in patients with painful hip presentations are discussed.

  19. Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Menk, Ralf Hendrik

    2008-01-01

    All standard (medical) x-ray imaging technologies, rely primarily on the amplitude properties of the incident radiation, and do not depend on its phase. This is unchanged since the discovery by Roentgen that the intensity of an x-ray beam, as measured by the exposure on a film, was related to the relative transmission properties of an object. However, recently various imaging techniques have emerged which depend on the phase of the x-rays as well as the amplitude. Phase becomes important when the beam is coherent and the imaging system is sensitive to interference phenomena. Significant new advances have been made in coherent optic theory and techniques, which now promise phase information in medical imaging. The development of perfect crystal optics and the increasing availability of synchrotron radiation facilities have contributed to a significant increase in the application of phase based imaging in materials and life sciences. Unique source characteristics such as high intensity, monochromaticity, coherence and high collimating provide an ideal source for advanced imaging. Phase contrast imaging has been applied in both projection and computed tomography modes, and recent applications have been made in the field of medical imaging. Due to the underlying principle of X-ray detection conventional image receptors register only intensities of wave fields and not their phases. During the last decade basically five different methods were developed that translate the phase information into intensity variations. These methods are based on measuring the phase shift φ directly (using interference phenomena), the gradient ∇ φ , or the Laplacian ∇ 2 φ. All three methods can be applied to polychromatic X-ray sources keeping in mind that the native source is synchrotron radiation, featuring monochromatic and reasonable coherent X-ray beams. Due to the vast difference in the coefficients that are driven absorption and phase effects (factor 1,000-10,000 in the energy

  20. Scintigraphic aspect of liver in hepatitis. [/sup 198/Au-radiocolloid

    Energy Technology Data Exchange (ETDEWEB)

    Silva, W M; Medeiros, M [Hospital dos Servidores do Estado, Rio de Janeiro (Brazil). Servico de Medicina Nuclear

    1976-01-01

    A series of scintigraphs was made in a group of 15 patients with viral hepatitis, and compared with biochemical tests. Although in some patients the last biochemical tests were only slightly elevated, and in others entirely normal, they all continued to show abnormal scintigraphs with a mottled aspect and splenic uptake. It is supposed that some sequellae remain in the hepatic tissue even though the patient responds well in clinical and laboratory tests.

  1. Phase Contrast Imaging

    DEFF Research Database (Denmark)

    1996-01-01

    The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation...... phasors attain predetermined values for predetermined spatial frequencies, and the phasor value of the specific resolution element of the spatial phase mask corresponds to a distinct intensity level of the image of the resolution element in the intensity pattern, and a spatial phase filter for phase...... shifting of a part of the electromagntic radiation, in combination with an imaging system for generation of the intensity pattern by interference in the image plane of the imaging system between the part of the electromagnetic raidation that has been phase shifted by the phase filter and the remaining part...

  2. Scintigraphic evaluation of gastrointestinal motility disorders

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Jae Gol [College of Medicine, Korea Univ., Seoul (Korea, Republic of)

    2001-02-01

    Current scintigraphic tests of gastrointestinal motor function provides relevant pathophysiologic information, but their clinical utility is controversial. Many scintigraphic methods are developed to investigate gastrointestinal motility from oral cavity to colon. These are esophageal transit scintigraphy, oropharyngeal transit study, gastric emptying test, small bowel transit time measurement, colon transit study and gastroesopahgeal reflux scintigraphy. Scintigraphy of gastrointestinal tract is the most physiologic and noninvasive method to evaluate gastrointestinal motility disorders. Stomach emptying test is regarded as a gold standard in motility study. Gastrointestinal transit scintigraphy also has a certain role in assessment of drug effect to GI motility and changes after theraphy of motility disorders. Scintigraphy provides noninvasive and quantitative assessment of physiological transit throughout the gastrointestinal tract, and it is extremely useful for diagnosing gastrointestinal motor dysfunction. This article reviews the current procedures, indications, significance and guidelines for gastrointestinal motility measurements by scintigraphy.

  3. Scintigraphic evaluation of gastrointestinal motility disorders

    International Nuclear Information System (INIS)

    Choe, Jae Gol

    2001-01-01

    Current scintigraphic tests of gastrointestinal motor function provides relevant pathophysiologic information, but their clinical utility is controversial. Many scintigraphic methods are developed to investigate gastrointestinal motility from oral cavity to colon. These are esophageal transit scintigraphy, oropharyngeal transit study, gastric emptying test, small bowel transit time measurement, colon transit study and gastroesopahgeal reflux scintigraphy. Scintigraphy of gastrointestinal tract is the most physiologic and noninvasive method to evaluate gastrointestinal motility disorders. Stomach emptying test is regarded as a gold standard in motility study. Gastrointestinal transit scintigraphy also has a certain role in assessment of drug effect to GI motility and changes after theraphy of motility disorders. Scintigraphy provides noninvasive and quantitative assessment of physiological transit throughout the gastrointestinal tract, and it is extremely useful for diagnosing gastrointestinal motor dysfunction. This article reviews the current procedures, indications, significance and guidelines for gastrointestinal motility measurements by scintigraphy

  4. Clinical, radiographic and scintigraphic aspects of the trapeziometacarpal osteoarthritis

    International Nuclear Information System (INIS)

    Kaziyama, Helena Hideko Seguchi

    1996-01-01

    Trapeziometacarpal osteoarthritis occurs mainly in women during the menopausal period. It is related to manual activities and is usually bilateral. The onset is insidious and the evolution is slow and progressive. It is characterized by of strength and pain in the basis of the thumb resulting in limitation of the use and function of the hand. The diagnosis of this condition is based on the physical examination. The manouver of compression axial-rotation of the trapezimetacarpal joint is a common positive finding. Typical findings of osteoarthritis are present in the radiological studies. Scintigraphic images have a predictive value. The early diagnosis is important to avoid the risk factors and to prevent disabilities of the hand. (author)

  5. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Callaghan, J.J.

    1989-01-01

    Although few reports address the use of three-phase bone scanning (TPBS) and 111 In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses

  6. Diagnosis of exercise-induced left bundle branch block at rest by scintigraphic phase analysis

    International Nuclear Information System (INIS)

    Schultz, D.A.; Wahl, R.L.; Juni, J.E.; Buda, A.J.; McMeekin, J.D.; Struble, L.R.; Tuscan, M.J.

    1986-01-01

    Accurate diagnosis of disease of the ventricular conducting system is essential for their appropriate therapy. Some conduction abnormalities, such as exercise-induced left bundle branch block (EX-LBBB), are not apparent on resting electrocardiograms. Phase analysis of rest and exercise radionuclide ventriculograms (RVG's) was used to compare four EX-LBBB patients with six normal controls. All patients had normal resting electrocardiograms, ejection fractions, and visually normal wall motion. First harmonic phase images were generated reflecting the timing of ventricular contraction. Dynamic phase displays were reviewed and graded in a blinded fashion by three independent experienced observers. Phase angle histograms of the right and left ventricle were determined for both resting and exercise images. The mean phase angle and standard deviation were also calculated for each ventricle. Visual grading of the resting phase images failed to show a significant difference between normal patients and patients with EX-LBBB. Quantitative analysis, however, revealed a significant difference in mean phase angle differences (LV-RV) in resting studies: 0.8 0 (+-1.9 0 SEM) in normal versus 9.3 0 (+-2.3 0 SEM) in EX-LBBB patients (P 0 in normals vs. 31.2 0 in EX-LBBB patients (P<0.001). Qualitative phase analysis of resting RVG's permits the diagnosis of cardiac conduction disease that is not apparent on the resting EKG and may result in better monitoring and treatment. (orig.)

  7. The acetabulum: A prospective study of three-phase bone and indium white blood cell scintigraphy following porous-coated hip arthroplasty

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Anderson, J.H.; Callaghan, J.J.

    1990-01-01

    Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy ( 111 In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111I n-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111 In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses

  8. Relevance of I-BMIPP delayed scintigraphic imaging for patients with angina pectoris - a pilot study.

    Science.gov (United States)

    Koyama, Kohei; Akashi, Yoshihiro J; Kida, Keisuke; Suzuki, Kengo; Ishibashi, Yuki; Musha, Haruki; Banach, Maciej

    2011-06-01

    The study was designed to clarify the role of (123)I-β-methyl-iodophenylpentadecanoic acid ((123)I-BMIPP) in the evaluation of myocardial fatty acid metabolism in patients with stable angina pectoris (AP) before and after percutaneous coronary intervention (PCI). TEN CONTROLS (MEAN AGE: 70.4 ±10.5 years) and 12 patients with AP (mean age: 67.4 ±11.6 years) and single vessel coronary artery disease participated in the radionuclide cardiac study. Scintigraphic images were acquired at 30 min and at 4 h after (123)I-BMIPP injection to determine early and delayed BMIPP uptake, respectively. The heart-to-mediastinum (H/M) ratio and the washout rate (WR) were calculated from the planar images. All patients underwent scintigraphy one day before PCI and again 1 month after successful PCI. NO SIGNIFICANT DIFFERENCES IN THE EARLY OR DELAYED H/M RATIOS WERE OBSERVED BETWEEN THE PATIENTS AND THE CONTROLS BEFORE PCI (EARLY: 2.70 ±0.36 vs. 2.73 ±0.57; delayed: 2.26 ±0.33 vs. 2.40 ±0.43; p > 0.2 for both). The early and delayed H/M ratios remained unchanged with the comparison with before PCI (early: 2.72 ±0.27, delayed: 2.23 ±0.22; p > 0.2 for both). The global WR before PCI was significantly higher in the patients than in the control group (36.7 ±9.3%, vs. 28.1 ±8.2%, p = 0.02). However, the WR after PCI did not significantly differ between the patients and the controls (34.3 ±7.8% vs. 28.1 ±8.2%, p = 0.1). These data may suggest that the WR of (123)I-BMIPP determined from the planar images enhances the presence of myocardial ischaemia.

  9. Analysis of stress fractures associated with lameness in Thoroughbred flat racehorses training on different track surfaces undergoing nuclear scintigraphic examination.

    Science.gov (United States)

    MacKinnon, M C; Bonder, D; Boston, R C; Ross, M W

    2015-05-01

    There is limited information regarding the impact of training track surface on the occurrence of stress fractures. To evaluate the impact of training track surface on the proportion of long bone and pelvic stress fractures associated with lameness in Thoroughbred horses in flat race training undergoing nuclear scintigraphic examination. Retrospective study. Scintigraphic examinations of Thoroughbred flat racehorses were evaluated from 2 hospitals (hospital A [Toronto Equine Hospital], 2003-2009, and hospital B [George D. Widener Hospital for Large Animals, School of Veterinary Medicine, University of Pennsylvania], 1994-2006). Horses admitted to hospital A trained at a single track, at which the main training surface changed from dirt to synthetic on 27 August 2006. Two distinct populations existed at hospital B: horses that trained on dirt (numerous trainers) and those that trained on turf (single trainer). All scintigraphic images were evaluated by a blinded reviewer. Fisher's exact test and logistic regression were used when appropriate, and significance was set at Pfractures detected in scintigraphic examinations from horses training on a synthetic surface (31.7%) in comparison to scintigraphic examinations from horses training on a dirt surface (23.0%) at an earlier point in time (P = 0.03). There was a greater proportion of hindlimb/pelvic and tibial stress fractures diagnosed in horses from the synthetic surface-trained group than from the dirt-trained group at hospital A (Pfractures diagnosed, but other factors, such as training philosophy, appear to be important. Future prospective investigations to fully elucidate the relationship between training track surface and the proportion of stress fractures and other nonfatal musculoskeletal injuries are warranted. © 2014 EVJ Ltd.

  10. Application of a general-purpose scintigraphic scanner to transverse-section (tomographic) gamma-ray imaging

    International Nuclear Information System (INIS)

    Bradstock, P.A.; Milward, R.C.

    1976-01-01

    The paper describes the recent application of a general-purpose commercial scintigraphic scanner to transverse-section radioisotope tomography. The principle of the method is to obtain the distribution of radioactive material in a thin transverse slice of the body or brain, from a mathematical reconstruction using the measured transverse projections of the activity within that slice. The usefulness of the radioisotope section-scanning technique for clinical diagnosis, as evidenced from one year's use of the machine at the Midland Centre for Neurology and Neurosurgery, Birmingham, U.K., is briefly discussed. (orig.) [de

  11. Development of superior bone scintigraphic agent from a series of {sup 99m}Tc-labeled zoledronic acid derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jianguo [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Qiu Ling, E-mail: qiulingwx@gmail.com [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Cheng Wen [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Luo Shineng, E-mail: shineng914@yahoo.com.cn [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Xue Li; Zhang Shu [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China)

    2012-05-15

    Two novel zoledronic acid (ZL) derivatives, 1-hydroxy-4-(1H-imidazol-1-yl)butane-1,1-diyldiphosphonic acid (IBDP) and 1-hydroxy-5-(1H-imidazol-1-yl)pentane-1,1-diyldiphosphonic acid (IPeDP), were prepared and labeled with the radionuclide technetium-99m in a high labeling yield. In vitro stabilities of these radiolabeled complexes were measured by the radio-HPLC analysis as a function of time, which showed excellent stability with the radiochemical purity of over 95% at 6 h post preparation. Their in vivo biological performances were evaluated and compared with those of {sup 99m}Tc-ZL and {sup 99m}Tc-MDP (methylenediphosphonic acid). The biodistribution in mice and scintigraphic images of the rabbit showed that the tracer agent {sup 99m}Tc-IPeDP had highly selective uptake in the skeletal system and rapid clearance from the blood and soft tissues and an excellent scintigraphic image can be obtained in a shorter time post injection with clear visualization of the skeleton and low soft tissue activity. These preclinical studies suggest that {sup 99m}Tc-IPeDP would be a novel superior bone scintigraphic agent. - Highlights: Black-Right-Pointing-Pointer Two novel diphosphonic acids were labeled with the {sup 99m}Tc in high labeling yield. Black-Right-Pointing-Pointer {sup 99m}Tc-IPeDP had high uptake in skeletal system and rapid clearance from blood. Black-Right-Pointing-Pointer {sup 99m}Tc-IPeDP reveals attractive biological features as superior bone scanning agent.

  12. Scintigraphic evaluation of traumatic splenic lesions in children

    International Nuclear Information System (INIS)

    Erasmie, U.; Mortensson, W.; Persson, U.; Laennergren, K.; St. Goerans Children's Hospital, Stockholm

    1988-01-01

    Ninety-eight children with recent blunt abdominal trauma which initially evoked clinical suspicion of splenic injury were examined with colloid scintigraphy of the spleen and the liver using multiple imaging views and with abdominal survey. Nineteen children were, in addition, examined with tomographic scintigraphy. The clinical findings and the course of the disorder were reanalysed. Scintigraphy indicated splenic injury in 56 children and hepatic injury in another 5 children. The left lateral and the left oblique were the optimum imaging views for detecting splenic ruptures. Tomographic scintigraphy did not improve the diagnostic yield. Abdominal survey failed to indicate almost every second case of splenic rupture and provided no additional information of significance. The clinical review agreed with the scintigraphic diagnosis of splenic lesions but, in addition, it suggested possible splenic lesions in another 10 children with normal scintigraphy. This discrepancy cannot be explained as surgery was not employed; the occurrence of splenic lesions too small to become detectable at scintigraphy or to provoke clinically evident symptoms may be supposed. (orig.)

  13. Novel CT and scintigraphic findings of bone metastasis from invasive lobular breast cancer

    International Nuclear Information System (INIS)

    Al-Ogaili, Zeyad; Troedson, Russell

    2016-01-01

    The aim of this study is to identify and describe the computed tomography and scintigraphic imaging patterns of osseous metastasis from invasive lobular breast cancer (ILC). CT and skeletal scintigraphy (SS) studies of 23 patients with diagnosis of ILC and osseous metastasis on their initial presentation were reviewed.Osseous metastases in 14 patients (60.8%) appear as uniform small sclerotic lesions (USSL) on CT scan. The SS in these patients were interpreted as negative for metastasis (either normal or with some equivocal findings not typical for metastasis). Osseous metastasis from ILC can have a characteristic imaging pattern on CT and SS. The pattern of USSL on CT scan with negative SS is highly suggestive of osseous metastasis from ILC.

  14. Scintigraphic evaluation of the esophageal-gastric function

    International Nuclear Information System (INIS)

    Taillefer, R.; Lefebvre, B.; Beauchamp, G.

    1986-01-01

    The authors present a brief review of the use of radionuclides in the pathophysiological evaluation of both esophageal and gastric function. Technical indications of these three following scintigraphic procedures are discussed: radionuclide esophagogram; gastro-esophogeal reflux study; and gastric emptying study

  15. Scintigraphic follow-up of fracture healing in animals

    International Nuclear Information System (INIS)

    Klug, W.; Franke, W.G.; Schulze, M.

    1983-01-01

    Secondary bone fracture heating was analysed by scintigraphic follow-up studies in rabbits using sup(99m)Tc-HEDP. 24 hours after fracture the activity ratio between the fractured and the non-fractured lower limb was 2,2. The maximal count density in the fracture region is found during the 14th and 28th day after fracture. Concomitantly there is a significant increase of bone marrow vessels and content of copper, magnesium, sodium and water in the callus. Although roentgenographic controls and static investigations with respect to consolidation reveal a complete heating already 126 days after fracture, the complete scintigraphic normalisation of the lower limb fracture of the rabbit is found not earlier than at the 203rd day after fracture. (orig.) [de

  16. Scintigraphic follow-up of fracture healing in animals

    Energy Technology Data Exchange (ETDEWEB)

    Klug, W.; Franke, W.G.; Schulze, M.

    1983-08-01

    Secondary bone fracture healing was analysed by scintigraphic follow-up studies in rabbits using sup(99m)Tc-HEDP. 24 hours after fracture the activity ratio between the fractured and the non-fractured lower limb was 2,2. The maximal count density in the fracture region is found during the 14th and 28th day after fracture. Concomitantly there is a significant increase of bone marrow vessels and content of copper, magnesium, sodium and water in the callus. Although roentgenographic controls and static investigations with respect to consolidation reveal a complete healing already 126 days after fracture, the complete scintigraphic normalisation of the lower limb fracture of the rabbit is found not earlier than at the 203rd day after fracture.

  17. The scintigraphic reaction pattern of traumatic bone lesions

    International Nuclear Information System (INIS)

    Spitz, J.

    1994-01-01

    The indications for bone scintigraphy in traumatology result: 1. Definite exclusion of bone lesions by normal scintigraphic findings (except for the scull). 2. Unclear result of X-ray or a mismatch between clinical investigation and X-ray result. 3. Screening after multiple injury which leads to the detection of an unknown bone lesion in every second patient. 4. Suspicion of a complicated healting course in cases of doubtful X-ray results. 5. The estimation of relative fracture age. This question always rises, if a pre-existing trauma or morphologic changes in X-ray make a clear diagnosis impossible. The additional information gained by bone scintigraphy is in part exclusive and not to be drawn from any other imaging modality. This renders bone scintigraphy to an important tool in the work up of medico-legal questions in traumatology. (orig.) [de

  18. Phase contrast image synthesis

    DEFF Research Database (Denmark)

    Glückstad, J.

    1996-01-01

    A new method is presented for synthesizing arbitrary intensity patterns based on phase contrast imaging. The concept is grounded on an extension of the Zernike phase contrast method into the domain of full range [0; 2 pi] phase modulation. By controlling the average value of the input phase funct...... function and by choosing appropriate phase retardation at the phase contrast filter, a pure phase to intensity imaging is accomplished. The method presented is also directly applicable in dark field image synthesis....

  19. Lymphoscintigraphy and breast cancer: early and/or late image?

    International Nuclear Information System (INIS)

    Rousseau, C.; Campion, L.; Curtet, C.; Classe, J.M.; Dravet, F.; Fiche, M.; Sagan, C.; Chatal, J.F.; Resche, I.

    2001-01-01

    As the performance of early (H+1 to 4) and late (D1) lympho-scintigraphic images raises organisational problems in outpatient surgery for breast cancer, only early images are generally obtained. The present study evaluated whether two series of images are better than one and defined the advantages of both methodologies On hundred and eighteen patients with infiltrating breast carcinoma (T0, T1 and T2) were included in the study : 87 in group A (early and late images) and 31 in group B (only early images). All patients received two peritumoral injections of 99m Tc-sulphur colloid: 15-18 MBq (group A) and < 15 MBq (group B). During the operation, the patent blue technique was associated with radioactivity detection. The two groups were comparable for histological type and tumour size and localization. Successful localisation of sentinel-nodes on early lympho-scintigraphic images was significantly greater for group B. The sensitivity of early lymphoscintigraphy increased by 10% during the study. Sentinel node detection by the isotopic method alone or the two methods combined was comparable for both groups. In radioactivity detection, the count rate for sentinel nodes versus background (contralateral breast) was superposable for the two groups. During the learning phase, two series of images gave a definite advantage. Subsequently, lymphoscintigraphy performed at + 2 h was sufficient (the results for the two groups became superposable). (author)

  20. Association of bone scintigraphic abnormalities with knee malalignment and pain.

    Science.gov (United States)

    Kraus, V B; McDaniel, G; Worrell, T W; Feng, S; Vail, T P; Varju, G; Coleman, R E

    2009-11-01

    The information content of knee bone scintigraphy was evaluated, including pattern, localisation and intensity of retention relative to radiographic features of knee osteoarthritis, knee alignment and knee symptoms. A total of 308 knees (159 subjects) with symptomatic and radiographic knee osteoarthritis of at least one knee was assessed by late-phase (99m)Technetium methylene disphosphonate bone scintigraph, fixed-flexion knee radiograph, full limb radiograph for knee alignment and for self-reported knee symptom severity. Generalised linear models were used to control for within-subject correlation of knee data. The compartmental localisation (medial vs lateral) and intensity of knee bone scan retention were associated with the pattern (varus vs valgus) (p<0.001) and severity (p<0.001) of knee malalignment and localisation and severity of radiographic osteoarthritis (p<0.001). Bone scan agent retention in the tibiofemoral, but not patellofemoral, compartment was associated with severity of knee symptoms (p<0.001) and persisted after adjusting for radiographic osteoarthritis (p<0.001). To the authors' knowledge, this is the first study describing a relationship between knee malalignment, joint symptom severity and compartment-specific abnormalities by bone scintigraphy. This work demonstrates that bone scintigraphy is a sensitive and quantitative indicator of symptomatic knee osteoarthritis. Used selectively, bone scintigraphy is a dynamic imaging modality that holds great promise as a clinical trial screening tool and outcome measure.

  1. Interest of scintigraphic imaging in Madagascar for the diagnosis of ectopic parathyroid adenoma, about one case

    International Nuclear Information System (INIS)

    Andriantsoa, J.; Andriamanalina, T.; Ramamonjy, A.; Ranivontsoarivony, M.; Ramahandridona, G.; Razafindramboa, H.; Gizy Ratiambahoaka, D.

    2008-01-01

    This study reports the first case of ectopic parathyroid adenoma, diagnosed in the Department of Nuclear Medicine in Antananarivo. This clinical vignette illustrates the interest of the MIBI-Tc-99 m scan in locating this adenoma and its diagnostic confirmation after six years of erratic diagnosis. A whole body bone scintigraphy has also allowed to assess the state of bone metabolism and study outbreaks of fracture. The parathyroid scintigraphy was carried out after intra-venous administration of 666 MBq of MIBI- 99m Tc. Dynamic images, static early and late static were acquired with a gamma camera E-Cam Siemens. The whole body bone scan was carried out after administration of 555 MBq of M.D.P.-Tc-99 m. The results evidenced the presence of an para-aortic increased uptake area pointing to a left parathyroid adenoma. The persistence of a late left sub maxillary increased uptake area raises, however, a reservation about the existence of a second adenoma. The bone scan displayed global skeletal remodeling, non suggestive of metastases, as it was mentioned with the CT-scan. In a diagnostic tools limited environment, skeletal pain refractory to pain-killers, a chronic hypercalcemia associated with an increased parathyroid hormone level, should trigger the scintigraphic exploration in order to avoid bone and renal complications

  2. Digital Data Processing of Images

    African Journals Online (AJOL)

    be concerned with the image enhancement of scintigrams. Two applications of image ... obtained from scintigraphic equipment, image enhance- ment by computer was ... used as an example. ..... Using video-tape display, areas of interest are ...

  3. Nuclear medicine image and data interchange through e-mail

    Energy Technology Data Exchange (ETDEWEB)

    Lyra, M; Skouroliakou, K; Perris, A; Georgossopoulos, C; Pappas, D [Radiology Department, Athens University, Athens (Greece); Stefanides, C [Pediatric Hospital, Aglaia Kyriakou, Athens (Greece)

    1999-12-31

    Prosperity of easy interchange in every day practice of Nuclear Medicine found its application through the INTERNET media. We use a simple and safe way to interchange images and diagnostic information between the scintigraphic acquisition and processing location and the clinical department in order to improve patient`s health care and young doctor`s education. images and patient reports are transferred and saved through dedicated software to a workstation that transforms y-camera scintigraphic images in a PC readable format. Diagnosis reports and scintigraphic images are incorporated to a database directory in hypertext form. Usual WWW connection gives the possibility of patients` examinations transfer by email attachments as well as interchange of relative comments towards both directions. Cost effective solution has been achieved using standard hard- and soft-ware. Furthermore, both educational files can be downloaded from our department ftp location, by a unique password. (authors) 7 refs., 3 figs.

  4. Nuclear medicine image and data interchange through e-mail

    International Nuclear Information System (INIS)

    Lyra, M.; Skouroliakou, K.; Perris, A.; Georgossopoulos, C.; Pappas, D.; Stefanides, C.

    1998-01-01

    Prosperity of easy interchange in every day practice of Nuclear Medicine found its application through the INTERNET media. We use a simple and safe way to interchange images and diagnostic information between the scintigraphic acquisition and processing location and the clinical department in order to improve patient's health care and young doctor's education. images and patient reports are transferred and saved through dedicated software to a workstation that transforms y-camera scintigraphic images in a PC readable format. Diagnosis reports and scintigraphic images are incorporated to a database directory in hypertext form. Usual WWW connection gives the possibility of patients' examinations transfer by email attachments as well as interchange of relative comments towards both directions. Cost effective solution has been achieved using standard hard- and soft-ware. Furthermore, both educational files can be downloaded from our department ftp location, by a unique password. (authors)

  5. Differentiated thyroid carcinoma in a scintigraphically hot nodule: diagnosis and interdisciplinary therapeutical approach

    International Nuclear Information System (INIS)

    Stahl, A.; Hess, U.; Langhammer, H.; Harms, J.; Zwicknagl, M.

    2002-01-01

    A hyperfunctioning differentiated thyroid carcinoma is a rare occurrence. Nevertheless, this diagnosis must be considered in a scintigraphically hot nodule if there is a clinical or sonographic suggestion of malignancy. The case of a 57-year old patient with hyperthyreosis and a scintigraphically hot thyroid nodule is presented. Further evaluation led to the diagnosis of a differentiated thyroid carcinoma with extensive lymph node and pulmonary metastases (pT2b, pN1b, pM1). The scintigraphically hot nodule corresponded to the primary tumor, whereas scintigraphic detection of the lymph node metastases was only possible postoperatively. Extensive resection of the lymph node metastases was achieved by the intraoperative application of a gamma probe (2nd operation). This allowed sufficient uptake of radioiodine in the pulmonary metastases for their detection and subsequent devitalization by radioiodine therapy. Complete elimination of all tumor tissue was documented at a control follow-up after six months. Gamma probe-guided surgery may allow for additional removement of non-palpable lymph node metastases. In selected cases this may optimize the surgical results and thereby facilitate the subsequent radioiodine elimination of advanced differentiated thyroid carcinomas. (author)

  6. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    in the experiment. Evaluation of one versus two scintigraphic projections, trials for assessment of the reproducibility, a comparison of the scintigraphic method with a water-plethysmographic method and registration of the fractional reduction in blood volume caused by exsanguination as a result of simple elevation......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation......We introduce a new method for evaluating reductions in local blood volumes in extremities, based on the combined use of autologue injection of 99mTc-radiolabelled erythrocytes and clamping of the limb blood flow by the use of a tourniquet. Twenty-two healthy male volunteers participated...

  7. Novel CT and scintigraphic findings of bone metastasis from invasive lobular breast cancer.

    Science.gov (United States)

    Al-Ogaili, Zeyad; Troedson, Russell

    2016-02-01

    The aim of this study is to identify and describe the computed tomography and scintigraphic imaging patterns of osseous metastasis from invasive lobular breast cancer (ILC). CT and skeletal scintigraphy (SS) studies of 23 patients with diagnosis of ILC and osseous metastasis on their initial presentation were reviewed. Osseous metastases in 14 patients (60.8%) appear as uniform small sclerotic lesions (USSL) on CT scan. The SS in these patients were interpreted as negative for metastasis (either normal or with some equivocal findings not typical for metastasis). Osseous metastasis from ILC can have a characteristic imaging pattern on CT and SS. The pattern of USSL on CT scan with negative SS is highly suggestive of osseous metastasis from ILC. © 2015 The Royal Australian and New Zealand College of Radiologists.

  8. Relevance of 123I-BMIPP delayed scintigraphic imaging for patients with angina pectoris – a pilot study

    Science.gov (United States)

    Koyama, Kohei; Akashi, Yoshihiro J.; Kida, Keisuke; Suzuki, Kengo; Ishibashi, Yuki; Musha, Haruki; Banach, Maciej

    2011-01-01

    Introduction The study was designed to clarify the role of 123I-β-methyl-iodophenylpentadecanoic acid (123I-BMIPP) in the evaluation of myocardial fatty acid metabolism in patients with stable angina pectoris (AP) before and after percutaneous coronary intervention (PCI). Material and methods Ten controls (mean age: 70.4 ±10.5 years) and 12 patients with AP (mean age: 67.4 ±11.6 years) and single vessel coronary artery disease participated in the radionuclide cardiac study. Scintigraphic images were acquired at 30 min and at 4 h after 123I-BMIPP injection to determine early and delayed BMIPP uptake, respectively. The heart-to-mediastinum (H/M) ratio and the washout rate (WR) were calculated from the planar images. All patients underwent scintigraphy one day before PCI and again 1 month after successful PCI. Results No significant differences in the early or delayed H/M ratios were observed between the patients and the controls before PCI (early: 2.70 ±0.36 vs. 2.73 ±0.57; delayed: 2.26 ±0.33 vs. 2.40 ±0.43; p > 0.2 for both). The early and delayed H/M ratios remained unchanged with the comparison with before PCI (early: 2.72 ±0.27, delayed: 2.23 ±0.22; p > 0.2 for both). The global WR before PCI was significantly higher in the patients than in the control group (36.7 ±9.3%, vs. 28.1 ±8.2%, p = 0.02). However, the WR after PCI did not significantly differ between the patients and the controls (34.3 ±7.8% vs. 28.1 ±8.2%, p = 0.1). Conclusions These data may suggest that the WR of 123I-BMIPP determined from the planar images enhances the presence of myocardial ischaemia. PMID:22295024

  9. /sup 99m/Tc-aminohexylidendiphosphonate and /sup 99/mTc-Pyrophosphate in the scintigraphic diagnosis of experimental cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Kafka, P; Mazurova, Y; Hadas, L; Vizda, J; Palicka, V; Grossman, V

    1987-10-01

    Experimental cardiomyopathy was provoked in 24 dogs with high intravenous doses of adrenaline and theophylline. These lesions were studied by means of the new agent /sup 99m/Tc-AHDP and /sup 99m/Tc-PYP in comparison. Cardiomyopathy could be imaged as early as 4 h after the onset of involvement but not later than 7 days. A maximum accumulation occurred in lesions 24 h old, /sup 99m/Tc uptake in the myocardium was graded scintigraphically, /sup 99m/Tc-AHDP was accumulated in the altered myocardium to a greater extent than /sup 99m/Tc-PYP. Scintigraphic findings were in good agreement with plasma levels of creatine-kinase. A comparison with histology demonstrated that the maximum accumulation of radiopharmaceuticals occurred at the time when the development of myocardium involvement reached the stage of myocytolysis.

  10. Scintigraphic appearances of Gaucher's disease

    International Nuclear Information System (INIS)

    Okada, Junichi; Uchiyama, Guio; Hayakawa, Kazushige; Araki, Tsutomu; Hayashi, Sanshin; Yamada, Kayoko; Seto, Kazuhiko

    1985-01-01

    Gaucher's disease is an inborn error of metabolism in which glucocerebroside accumlates within reticuloendotherial cells of spleen, liver and bone marrow. The scintigraphic appearances are described in a 19-year-old man with Gaucher's disease. The colloid scan showed increased uptake in the lung and bone marrow of legs where the reticuloendotherial system was activated. The bone scan demonstrated increased activity in the metaphyseal and diaphyseal region infiltrated by Gaucher's cell. Ga-67 was thought to be accumlated in the progressive focus of the disease. (author)

  11. Right ventricular function: methodologic and clinical considerations in noninvasive scintigraphic assessment

    International Nuclear Information System (INIS)

    Manno, B.V.; Iskandrian, A.S.; Hakki, A.H.

    1984-01-01

    Right ventricular function plays an important role in many cardiac disorders. Changes in left ventricular function, right ventricular afterload and preload, cardiac medications and ischemia may affect right ventricular function. Radionuclide ventriculography permits quantitative assessment of regional and global function of the right ventricle. This assessment can be made at rest, during exercise or after pharmacologic interventions. The overlap between right ventricle and right atrium is a major limitation for gated scintigraphic techniques. The use of imaging with newer short-lived radionuclides may permit more accurate and reproducible assessment of right ventricular function by means of the first pass method. Further work in areas related to improvement of techniques and the impact of right ventricular function on prognosis is needed

  12. Radiographic and scintigraphic evaluation of total knee arthroplasty

    International Nuclear Information System (INIS)

    Schneider, R.; Soudry, M.

    1986-01-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic total knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent

  13. Using the phase-space imager to analyze partially coherent imaging systems: bright-field, phase contrast, differential interference contrast, differential phase contrast, and spiral phase contrast

    Science.gov (United States)

    Mehta, Shalin B.; Sheppard, Colin J. R.

    2010-05-01

    Various methods that use large illumination aperture (i.e. partially coherent illumination) have been developed for making transparent (i.e. phase) specimens visible. These methods were developed to provide qualitative contrast rather than quantitative measurement-coherent illumination has been relied upon for quantitative phase analysis. Partially coherent illumination has some important advantages over coherent illumination and can be used for measurement of the specimen's phase distribution. However, quantitative analysis and image computation in partially coherent systems have not been explored fully due to the lack of a general, physically insightful and computationally efficient model of image formation. We have developed a phase-space model that satisfies these requirements. In this paper, we employ this model (called the phase-space imager) to elucidate five different partially coherent systems mentioned in the title. We compute images of an optical fiber under these systems and verify some of them with experimental images. These results and simulated images of a general phase profile are used to compare the contrast and the resolution of the imaging systems. We show that, for quantitative phase imaging of a thin specimen with matched illumination, differential phase contrast offers linear transfer of specimen information to the image. We also show that the edge enhancement properties of spiral phase contrast are compromised significantly as the coherence of illumination is reduced. The results demonstrate that the phase-space imager model provides a useful framework for analysis, calibration, and design of partially coherent imaging methods.

  14. Phase-space evolution of x-ray coherence in phase-sensitive imaging.

    Science.gov (United States)

    Wu, Xizeng; Liu, Hong

    2008-08-01

    X-ray coherence evolution in the imaging process plays a key role for x-ray phase-sensitive imaging. In this work we present a phase-space formulation for the phase-sensitive imaging. The theory is reformulated in terms of the cross-spectral density and associated Wigner distribution. The phase-space formulation enables an explicit and quantitative account of partial coherence effects on phase-sensitive imaging. The presented formulas for x-ray spectral density at the detector can be used for performing accurate phase retrieval and optimizing the phase-contrast visibility. The concept of phase-space shearing length derived from this phase-space formulation clarifies the spatial coherence requirement for phase-sensitive imaging with incoherent sources. The theory has been applied to x-ray Talbot interferometric imaging as well. The peak coherence condition derived reveals new insights into three-grating-based Talbot-interferometric imaging and gratings-based x-ray dark-field imaging.

  15. Diffuse lung uptake (DLU) on Ga-67 scintigraph: Clinical, radiologic and pathologic correlation

    International Nuclear Information System (INIS)

    Sy, W.M.; Seo, I.S.; Vieira, J.; Zaman, M.

    1985-01-01

    Review, analysis and correlation (clinical, radiologic and pathologic) of 29 consecutive adults (16 drug addicts and/or homosexuals) with DLU on Ga-67 scintigraph were made. Diffuse increased uptake of at least 75% of both lungs was considered as DLU. WFOF cameras were used to obtain 24 to 96 hr. scintigraphs after IV injection of 3-5 mCi of Ga-67 citrate. In 26, tissue diagnosis established: pneumocystis carinii (PC) 15, miliary tuberculosis (TB) 3, sarcoidosis (SR) 3, drug-induced toxicity 2, and toxoplasmosis (TX), primary hyperparathyroidism and nonspecific lymphocytic pneumonia-one each. In two with breast and one with esophageal carcinomas, no lung tissue diagnosis was sought. Concurrent chest x-rays were negative in 16, but in 7/16, lung infiltrate was later documented. An average of 31 days elapsed before x-rays became positive in four with PC, 7 days in two with TB, and 22 days in one with TX. In 13, concurrent x-rays showed lung infiltrate, but in 6, only subtle, localized rather than diffuse infiltrate was noted. Fourteen of 29 had at least two Ga-67 studies. In 12 (7 PC, 2 TB, 3 SR) of 14 whose repeat studies showed significant to total disappearance of DLU, all did well clinically. In two whose initial studies were negative or equivocal, they became clinically worse when the repeat study showed DLU. In three others (2 PC, 1 TX) who died, their single studies recorded intense DLU. DLU on gallium scintigraph indicated a variety of pathology. In 55.2%, gallium scintigraph predated x-ray findings by a few days to weeks. In 20.3%, x-ray findings were only subtle or localized. Scintigraphic changes correlated well with the clinical courses in various diseases

  16. Scintigraphic evaluation of the osteoblastic activity of rabbit tibial defects after HYAFF11 membrane application.

    Science.gov (United States)

    Mermerkaya, Musa Uğur; Doral, Mahmut Nedim; Karaaslan, Fatih; Huri, Gazi; Karacavuş, Seyhan; Kaymaz, Burak; Alkan, Erkan

    2016-05-03

    An unfavorable condition for bone healing is the presence of bone defects. Under such conditions, a material can play a role to cover fractured or defective bone. Technological advances now allow for the use of such material. Hyalonect(®) (Fidia Advanced Biopolymers SLR, Italy), a novel membrane comprising knitted fibers of esterified hyaluronan (HYAFF11) can be used to cover fractured or grafted bone and can also serve as a scaffold to keep osteoprogenitor cells in place. The aim of this study was to compare osteoblastic activity by the use of scintigraphic methods in defective rabbit tibias during early-phase bone healing with or without a hyaluronan-based mesh. Two groups (A and B) of New Zealand albino rabbits were used; each group included 10 animals. Operations on all rabbits were performed under general anesthesia. We also resected 10-mm bone segments from each animal's tibial diaphysis. After resection, tibias with defects were fixed using Kirschner wires. In group A, no hyaluronan-based mesh was used. In group B, tibial segmental defects were enclosed with a hyaluronan-based mesh. The rabbits were followed up for 4 weeks postoperatively, after which bone scintigraphic studies were performed on each animal to detect and compare osteoblastic activity. The mean count in the fracture side of the hyaluronan-based mesh group was significantly higher compared to that of the group A (p = 0.019). However, there was no significant difference between group B and control rabbits with respect to the mean count on the intact bone side (p = 0.437). The bone defect (fracture)/intact bone mean count ratio was significantly higher in group B compared to group A (p = 0.008). A hyaluronan-based mesh plays a role in promoting osteoblastic activity. Hyalonect(®) is suitable for restoring tissue continuity whenever the periosteal membrane is structurally impaired or inadequate. Our results demonstrated that, during early-phase bone healing, osteoblastic activity

  17. Scintigraphic ventriculography and stress testing

    International Nuclear Information System (INIS)

    Goris, M.L.; Hung, J.; Debusk, R.F.

    1982-01-01

    Scintigraphic stress ventriculography yields information which is complex and defies description by the difference in ejection fraction between rest and maximum exercise only. The complexity results in part from the ''derived'' nature of the ejection fraction measurement, which is physiologically secondary to stroke volume and end-diastolic volume. Furthermore, the nature of the stress test in which the pulse (stress) is not independent from the response forces an analysis which considers ''when'' as much as ''what'' happens. Automation in data processing, however, has made oversimplification unnecessary and allows a more exhaustive but correct analysis

  18. Dual focal-spot imaging for phase extraction in phase-contrast radiography

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2003-01-01

    The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as 'unsharp masking' but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects

  19. Acetabular stress fractures in military endurance athletes and recruits: incidence and MRI and scintigraphic findings

    International Nuclear Information System (INIS)

    Williams, T.R.; Puckett, M.L.; Shin, A.Y.; Gorman, J.D.; Denison, G.

    2002-01-01

    Objective: To evaluate the incidence and the MRI and scintigraphic appearance of acetabular stress (fatigue) fractures in military endurance athletes and recruits. Design and patients: One hundred and seventy-eight active duty military endurance trainees with a history of activity-related hip pain were evaluated by both MRI and bone scan over a 2-year period. Patients in the study ranged in age from 17 to 45 years. They had hip pain related to activity and had plain radiographs of the hip and pelvis that were interpreted as normal or equivocal. The study was originally designed to evaluate the MRI and scintigraphic appearance of femoral neck stress fractures. Patients had scintigraphy and a limited MRI examination (coronal imaging only) within 48 h of the bone scan. Twelve patients demonstrated imaging findings compatible with acetabular stress fractures. Results: Stress fractures are common in endurance athletes and in military populations; however, stress fracture of the acetabulum is uncommon. Twelve of 178 patients (6.7%) in our study had imaging findings consistent with acetabular stress fractures. Two patterns were identified. Seven of the 12 (58%) patients had acetabular roof stress fractures. In this group, two cases of bilateral acetabular roof stress fractures were identified, one with a synchronous tensile sided femoral neck stress fracture. The remaining five of 12 (42%) patients had anterior column stress fractures, rarely occurring in isolation, and almost always occurring with inferior pubic ramus stress fracture (4 of 5, or 80%). One case of bilateral anterior column stress fractures was identified without additional sites of injury. Conclusions: Stress fractures are commonplace in military populations, especially endurance trainees. Acetabular stress fractures are rare and therefore unrecognized, but do occur and may be a cause for activity-related hip pain in a small percentage of military endurance athletes and recruits. (orig.)

  20. Scintigraphic and clinical findings in the Standardbred metatarsophalangeal joint: 114 cases (1993-1995)

    International Nuclear Information System (INIS)

    Ross, M.W.

    1998-01-01

    To correlate scintigraphic and clinical findings of the metatarsophalangeal joint (MTPJ) in Standardbreds, radiographic findings in horses with confirmed MTPJ lameness, and determine if stress reaction and more advanced bone remodelling occurred in the MTPJ, medical records of 114 Standardbreds admitted between September 1993 and April 1995 in which bone scintigraphy included standing lateral and plantar views of the metatarsophalangeal joint (MTPJ) were reviewed. Images obtained using a large field of view gamma camera were evaluated visually for location, definition and intensity of increased radioisotope uptake (IRU), which was graded as mild, moderate, or intense. Clinical history and lameness examination findings were recorded and, in horses with documented MTPJ lameness, radiographic examination included the 30 degree (down-angled) dorsolateral 45 degree plantaromedial view thought to be useful in evaluation of the plantarolateral condyle of the third metatarsal bone (MtIII). The most common abnormality, IRU of the plantarolateral aspect of MtIII, was seen in 67 horses, and horses were further classified according to scintigraphic and clinical findings. In 43 horses in which lameness was not localised to the MTPJ, mild (32 horses), moderate (10 horses), and intense (one horse) IRU of MtHII was found. In 24 horses with lameness localised to the MTPJ, moderate (18 horses) and intense (6 horses) IRU was found. Of 18 horses with moderate IRU of MtIII, 9 had radiographic evidence of abnormal bony remodelling of MtIII, whereas 5 of 6 horses with intense IRU had radiographic changes. In 12 horses with MTPJ lameness and radiographic evidence of bony remodelling without fracture, radiographic changes consisted of plantarolateral subchondral radiolucency and sclerosis (7 horses), radiolucency and osteochondrosis (one horse), and plantar MtIII sclerosis without radiolucency (4 horses). In 2 horses with moderate IRU and MTPJ lameness, radiographic evidence of

  1. Image fusion in x-ray differential phase-contrast imaging

    Science.gov (United States)

    Haas, W.; Polyanskaya, M.; Bayer, F.; Gödel, K.; Hofmann, H.; Rieger, J.; Ritter, A.; Weber, T.; Wucherer, L.; Durst, J.; Michel, T.; Anton, G.; Hornegger, J.

    2012-02-01

    Phase-contrast imaging is a novel modality in the field of medical X-ray imaging. The pioneer method is the grating-based interferometry which has no special requirements to the X-ray source and object size. Furthermore, it provides three different types of information of an investigated object simultaneously - absorption, differential phase-contrast and dark-field images. Differential phase-contrast and dark-field images represent a completely new information which has not yet been investigated and studied in context of medical imaging. In order to introduce phase-contrast imaging as a new modality into medical environment the resulting information about the object has to be correctly interpreted. The three output images reflect different properties of the same object the main challenge is to combine and visualize these data in such a way that it diminish the information explosion and reduce the complexity of its interpretation. This paper presents an intuitive image fusion approach which allows to operate with grating-based phase-contrast images. It combines information of the three different images and provides a single image. The approach is implemented in a fusion framework which is aimed to support physicians in study and analysis. The framework provides the user with an intuitive graphical user interface allowing to control the fusion process. The example given in this work shows the functionality of the proposed method and the great potential of phase-contrast imaging in medical practice.

  2. NEPHRUS: model of intelligent multilayers expert system for evaluation of the renal system based on scintigraphic images analysis; NEPRUS: modelo de sistema especialista em multicamadas inteligentes para avaliacao do sistema urinario baseado na analise de imagens cintilograficas

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jose W.E. da; Schirru, Roberto [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia; Boasquevisque, Edson M. [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear

    1997-10-01

    This work develops a prototype for the system model based on Artificial Intelligence devices able to perform functions related to scintigraphic image analysis of the urinary system. Criteria used by medical experts for analysis images obtained with {sup 99m} Tc+DTPA and/or {sup 99m} Tc+DMSA were modeled and a multi resolution diagnosis technique was implemented. Special attention was given to the programs user interface design. Human Factor Engineering techniques were considered so as to ally friendliness and robustness. Results obtained using Artificial Neural Networks for the qualitative image analysis and the knowledge model constructed shows the feasibility of Artificial Intelligence implementation that use `inherent` abilities of each technique in the resolution of diagnosis image analysis problems. (author). 12 refs., 2 figs., 2 tabs.

  3. Scintigraphic evaluation of brain death

    International Nuclear Information System (INIS)

    Park, C. H.; Bai, M. S.; Cho, K. K.; Kim, S. J.; Yoon, S. N.; Cho, C. W.

    1997-01-01

    A law recognizing brain death is a life saving legal measure in patients suffering from badly diseased organs such as kidney, liver, heart, and lung. Such law is being discussed for legalization at the Korean National Assembly. There are various criteria used for brain death in western world and brain scintiscan is one of them. However, the scintiscan is not considered in establishing brain death in the draft of the law. The purpose of this report is to spread this technique in nuclear medicine society as well as in other medical societies. We evaluated 7 patients with clinical suspicion of brain death by various causes. The patient's age ranged from 5 to 39 years. We used 5-20mCi 99m Tc-HMPAO (d.1-hexamethyl propylene amine oxime) or ECD (Ethyl Cysteinate Dimer), lipophilic agents that cross BBB (blood brain barrier). A dynamic study followed by static or SPECT (single photon emission tomography) was performed. Interpretive criteria used for brain death were 1) no intracranial circulation 2) no brain uptake. The second criteria is heavily used. Five of 7 patients were scintigraphically brain dead and the remaining 2 had some brain uptake excluding the diagnosis of scintigraphic brain death. In conclusion, cerebral perfusion study using a lipophilic brain tracer offers a noninvasive, rapid, easy, accurate and reliable mean in the diagnosis of brain death. We believe that this modality should be included in the criteria of brain death in the draft of the proposed Korean law

  4. Scintigraphic localization of a disseminated malignant pheochromocytoma with the use of 131I-meta-iodobenzylguanidine

    International Nuclear Information System (INIS)

    Troncone, L.; Maini, L.M.; Rufini, V.; Bonifazi, N.; De Rosa, G.; Corsello, S.M.; Mattei, O.

    1984-01-01

    Preliminary clinical studies with 131 I-meta-iodo-benzylguanidine, a newly synthesized radiopharmaceutical and guanethidine analog capable of imaging the adrenal medulla, have led to the identification, of a case of disseminated malignant pheochromocytoma with the localization of brain and bone metastases. The result is of particular interest as the symptomatology in this case appeared rather equivocal and various investigations had led to a completely different diagnosis. This new scintigraphic technique has proved to be safe, specific and noninvasive, and it may have a clinical application as a complementary or alternative technique to conventional diagnostic tests. (orig.)

  5. Scintigraphic findings in ankylosing spondylitis.

    Science.gov (United States)

    Lentle, B C; Russell, A S; Percy, J S; Jackson, F I

    1977-06-01

    A prospective study of bone scintigraphic findings has been carried out in 63 patients, firmly diagnosed as having ankylosing spondylitis. In addition to abnormal uptake of the radiotracer at the sacroiliac joints, a peripheral arthropathy has been a common finding, particularly in the proximal joints, occurring in up to 50% of patients. Increased uptake of radiotracer in the spine has also been found both diffusely and focally. Focal increases have been noted at the apophyseal joints in 40% of patients and in three patients with a sterile intervertebral diskitis, an unusual complication of this disease only diagnosed in two patients after bone scintigraphy.

  6. Scintigraphic imaging with technetium-99M-labelled ceftizoxime is a reliable technique for the diagnosis of deep sternal wound infection in rats

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Henrique Nogueira; Diniz, Simone Odilia Fernandes; Cardoso, Valbert Nascimento; Tarabal, Bernardo; Takenaka, Isabella; Braga, Otavio; Vidigal, Paula Vieira Teixeira; Gelape, Claudio Leo; Araujo, Ivana Duval, E-mail: phnc@uol.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2015-07-01

    Purpose: to evaluate whether scintigraphy with technetium-99m-labeled ceftizoxime ({sup 99m}Tc-CFT) can differentiate mediastinitis from aseptic inflammation associated with sternotomy. Methods: twenty female Wistar rats were randomly distributed into four groups: S (control) -partial upper median sternotomy with no treatment; SW (control) - sternotomy and treatment of sternal wounds with bone wax; SB - sternotomy and infection with Staphylococcus aureus; SWB - sternotomy with bone wax treatment and bacterial infection. Scintigraphy with {sup 99m}Tc-CFT was performed eight days after surgery and images were collected 210 and 360 min after infusion of the radiopharmaceutical. Results: no animals exhibited clinical signs of wound infection at the end of the experiment, although histological data verified acute inflammatory response in those experimentally infected with bacteria. Scintigraphic images revealed that tropism of {sup 99m}Tc-CFT to infected sternums was greater than to their non-infected counterparts. Mean counts of radioactivity in bacteria-infected sternal regions (SB and SWB) were significantly higher (p = 0.0007) than those of the respective controls (S and SW).Conclusion: scintigraphy with technetium-99m-labeled ceftizoxime is a method that can potentially detect infection post sternotomy and differentiate from aseptic inflammation in animals experimentally inoculated with S. aureus (author)

  7. Scintigraphic evidence of transplanted hepatocytes in spleen and liver

    International Nuclear Information System (INIS)

    Henne-Bruns, D.; Kremer, B.; Gramminger, K.; Broelsch, C.

    1986-01-01

    In rats suffering from hepatic enzymatic deficiency transplanted hepatocytes could be evidenced scintigraphically in liver, spleen and granulomas. In pigs, however, it is very difficult to demonstrate transplanted hepatocytes by scintiscanning because of the thickness of the tissues and the high background radiation in large animals

  8. Scintigraphic measurement of colonic transit in patients with idiopathic constipation

    International Nuclear Information System (INIS)

    Yoon, K. H.; Kim, C. K.

    1999-01-01

    To evaluate usefulness of scintigraphic measurement of total and regional colonic transit in patients with idiopathic constipation. 25 patients who were complained chronic constipation underwent scintigraphic measurement of the total and regional colon transit. Of them 10 patients were diagnosed as idiopathic constipation, none of whom had evidence of abnormal function of the pelvic floor. Ten healthy volunteers were also studied. 67 Gallium-labelled Amberlite resin particles were ingested in a coated capsule with methacrylate that dispersed in the ileocecal region. Images were obtained using a gamma camera at regular intervals for the 2, 4, 8, 24, and 48 hours after the initial counting of the radioactivity in the cecum. We determined the geometric center in four regions of interest in the colon (ascending, transverse, descending, and rectosigmoid). Ten patients with colonic inertia showed significant retention of solid residue in the ascending and transverse colon over a 48-hour period. The median values for the healthy subjects at 2, 4, 8, and 24, and 48 hours were 1.44±0.2 (midway through ascending), 1.71±0.45 (midway through transverse), 2.64±0.95 (midway through descending), 3.94±0.89 (midway through rectosigmoid), and 4.52±0.76 (midway through the stool compartment). On the contrary, the values of ten patients with colonic inertia were 1.0±0.0 (midway through ascending), 1.0±0.0 (midway through ascending). 1.02 ±0.06 (midway through ascending), 1.70±0.36 (midway through transverse), and 2.33±0.31(midway through descending) at the same time (p<0.001). In patients with idiopathic constipation is characterized by exaggerated reservoir factions of the ascending and transverse colons. Scintigraphy using 67 Gallium-labelled pellets seems to be a useful tool to demonstrate the delayed colonic transit in patients with colonic inertia

  9. Scintigraphic measurement of colonic transit in patients with idiopathic constipation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K. H.; Kim, C. K. [College of Medicine, Wonkwang Univ., Iksan (Korea, Republic of)

    1999-07-01

    To evaluate usefulness of scintigraphic measurement of total and regional colonic transit in patients with idiopathic constipation. 25 patients who were complained chronic constipation underwent scintigraphic measurement of the total and regional colon transit. Of them 10 patients were diagnosed as idiopathic constipation, none of whom had evidence of abnormal function of the pelvic floor. Ten healthy volunteers were also studied. 67 Gallium-labelled Amberlite resin particles were ingested in a coated capsule with methacrylate that dispersed in the ileocecal region. Images were obtained using a gamma camera at regular intervals for the 2, 4, 8, 24, and 48 hours after the initial counting of the radioactivity in the cecum. We determined the geometric center in four regions of interest in the colon (ascending, transverse, descending, and rectosigmoid). Ten patients with colonic inertia showed significant retention of solid residue in the ascending and transverse colon over a 48-hour period. The median values for the healthy subjects at 2, 4, 8, and 24, and 48 hours were 1.44{+-}0.2 (midway through ascending), 1.71{+-}0.45 (midway through transverse), 2.64{+-}0.95 (midway through descending), 3.94{+-}0.89 (midway through rectosigmoid), and 4.52{+-}0.76 (midway through the stool compartment). On the contrary, the values of ten patients with colonic inertia were 1.0{+-}0.0 (midway through ascending), 1.0{+-}0.0 (midway through ascending). 1.02 {+-}0.06 (midway through ascending), 1.70{+-}0.36 (midway through transverse), and 2.33{+-}0.31(midway through descending) at the same time (p<0.001). In patients with idiopathic constipation is characterized by exaggerated reservoir factions of the ascending and transverse colons. Scintigraphy using 67 Gallium-labelled pellets seems to be a useful tool to demonstrate the delayed colonic transit in patients with colonic inertia.

  10. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  11. Scintigraphic analysis of thyroid diseases at the Lagos University ...

    African Journals Online (AJOL)

    This paper presents a retrospective analysis of randomly selected clinical scintigraphic records at the College of Medicine/Lagos University Teaching Hospital, Nigeria. Out of the 436 patients scanned for various thyroid abnormalities, 266 (61.0%) were used for the analysis due to insufficient data and parameters required ...

  12. Scintigraphic evaluation of floating, gastroretentive formulation of clarithramycin in healthy human volunteers

    International Nuclear Information System (INIS)

    Ali, Raisuddin; Aji Alex, M.R.; Dutta, M.; Singh, Thakuri; Bhatnagar, A.; Bajaj, M.; Singla, Y.P.; Ahmad, F.J.; Khar, R.K.

    2010-01-01

    Full text: Objective of the present study concerns formulation and evaluation of oral buoyant effervescent tablets of clarithromycin for prolongation of gastric residence time (GRT) and to enhance eradication of Helicobacter pylori (H. pylori) for longer period of time. Materials and Methods: Clarithromycin (CLA) a macrolide antibiotic was chosen as the candidate drug for its immense potential as an Anti H. pylori agent. HPMC and/or xanthan gum were used as release-retarding polymer(s) whereas sodium bicarbonate (NaHCO 3 ) was utilized as a gas former. The tablets were prepared by wet granulation method. Formulations were evaluated for physicochemical properties, in vitro drug release as well as drug release kinetics and stability studies. In vivo gamma scintigraphic studies were assessed for the optimized buoyant gastroretentive tablets in six healthy human volunteers to study influence of nature of the dosage form i.e. conventional or sustained release gastroretentive tablets and the presence of food in the stomach on intragastric performance of gastroretentive tablets. Result: The fabricated tablets showed acceptable physiochemical properties. Non-fickian release transport was confirmed as the drug release mechanism from the prepared tablets. Optimized tablets composed of HPMC K15M, xanthan gum, and NaHCO 3 were promising systems exhibiting excellent floating properties. The overall performance was found to be highly sustained. Scintigraphic imaging revealed GRT of 320 min or more in fed state on the other hand GRT of 180 min or less in case of unfed state. Conclusion: The developed gastroretentive system has potential to increase efficacy of the therapy and improve patient

  13. Impact of SPECT/CT in imaging inflammation and infection; Wertigkeit der SPECT/CT fuer die nuklearmedizinische Entzuendungsdiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R. [Klinikum Bremen-Mitte, Bremen (Germany). Klinik fuer Nuklearmedizin; Kuwert, T. [Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik

    2011-03-15

    Even today infection remains a significant concern, and the diagnosis and localization of infectious foci is an important health issue. As an established infection-imaging modality, nuclear medicine plays a vital health-care role in the diagnosis and subsequent effective treatment of this condition. Several techniques in nuclear medicine significantly aid infection diagnosis, including triple-phase bone scanning, {sup 18}F-FDG-PET and imaging with {sup 111}In-oxine-, {sup 99m}Tc-HMPAO-labeled leukocytes. Each radiopharmaceutical has specific advantages and disadvantages that makes it suitable to diagnose different infectious processes (e.g., soft-tissue sepsis, inflammatory bowel disease, osteomyelitis, occult fever, fever of unknown origin, and infections commonly found in immuno-compromised patients). However, their clinical applications may be limited by the relatively low spatial resolution and the lack of anatomic landmarks of a highly specific tracer with only scarce background uptake to use as a framework for orientation. Anatomic imaging modalities such as CT provide a high-quality assessment of structural abnormalities related to infection, but these structural abnormalities may be unspecific. Furthermore, to detect infection before anatomical changes are present, functional imaging could have some advantages over anatomical imaging. Scintigraphic studies have demonstrated high sensitivity and specificity to an infectious process. Diagnosis and precise delineation of infection may be challenging in certain clinical scenarios, rendering decisions concerning further patient management difficult. The SPECT/CT-technology combines the acquisition of SPECT and CT data with the same imaging device enabling perfect overlay of anatomical and functional images. SPECT/CT imaging data has been shown to be beneficial for many clinical settings such as indeterminate findings in bone scintigraphy, orthopaedic disorders, endocrine, and neuroendocrine tumors. Therefore

  14. 99m-Tc HMDP bone scintigraphic findings of gouty arthropathy of both hands

    International Nuclear Information System (INIS)

    Shih, Wei-Jen; Domstad, P.A.; Purcell, M.; DeLand, F.H.

    1988-01-01

    The 99m Tc hydroxy methylene diphosphonate scintigraphic findings of both hands are correlated to the radiographic findings in a patient with a 30-year history of gouty arthropathy. Scintigraphic differentiation of the type of arthritis on the basis of uptake pattern is difficult. However, the findings of rheumatoid arthritis are confined to the joints and usually the involvement is symmetrical. With gout there is a tendency toward asymmetrical, bilateral, multifocal joint involvement with areas of intense abnormal uptake; because of the associated soft tissue swelling, the intense uptake usually extends beyond the involved joints. (author)

  15. Scintigraphic findings in ankylosing spondylitis

    International Nuclear Information System (INIS)

    Lentle, B.C.; Russell, A.S.; Percy, J.S.; Jackson, F.I.

    1977-01-01

    A prospective study of bone scintigraphic findings has been carried out in 63 patients, firmly diagnosed as having ankylosing spondylitis. In addition to abnormal uptake of the radiotracer at the sacroiliac joints, a peripheral arthropathy has been a common finding, particularly in the proximal joints, occurring in up to 50 percent of patients. Increased uptake of radiotracer in the spine has also been found both diffusely and focally. Focal increases have been noted at the apophyseal joints in 40 percent of patients and in three patients with a sterile intervertebral diskitis, an unusual complication of this disease only diagnosed in two patients after bone scintigraphy

  16. Boron nitride nanotubes radiolabeled with ⁹⁹mTc: preparation, physicochemical characterization, biodistribution study, and scintigraphic imaging in Swiss mice.

    Science.gov (United States)

    Soares, Daniel Crístian Ferreira; Ferreira, Tiago Hilário; Ferreira, Carolina de Aguiar; Cardoso, Valbert Nascimento; de Sousa, Edésia Martins Barros

    2012-02-28

    In the present study, boron nitride nanotubes (BNNTs) were synthesized from an innovative process and functionalized with a glycol chitosan polymer in CDTN (Centro de Desenvolvimento da Tecnologia Nuclear) laboratories. As a means of studying their in vivo biodistribution behavior, these nanotubes were radiolabeled with (99m)Tc and injected in mice. Their size, distribution, and homogeneity were determined by photon correlation spectroscopy (PCS), while their zeta potential was determined by laser Doppler anemometry. The morphology and structural organization were evaluated by scanning electron microscopy (SEM). The functionalization in the nanotubes was evaluated by thermogravimetry analysis (TGA) and Fourier transformer infrared spectroscopy. The results showed that BNNTs were obtained and functionalized successfully, reaching a mean size and dispersity deemed adequate for in vivo studies. The BNNTs were also evaluated by ex vivo biodistribution studies and scintigraphic imaging in healthy mice. The results showed that nanostructures, after 24h, having accumulated in the liver, spleen and gut, and eliminated via renal excretion. The findings from this study reveal a potential application of functionalized BNNTs as new potential drugs or radioisotope nanocarriers to be applied in therapeutic procedures. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. External scintigraphy in monitoring the behavior of pharmaceutical formulations in vivo I: technique for acquiring high-resolution images of tablets

    International Nuclear Information System (INIS)

    Theodorakis, M.C.; Simpson, D.R.; Leung, D.M.; Devous, M. Sr.

    1983-01-01

    A new method for monitoring tablet disintegration in vivo was developed. In this method, the tablets were labeled with a short-lived radionuclide, technetium 99m, and monitored by a gamma camera. Several innovations were introduced with this method. First, computer reconstruction algorithms were used to enhance the scintigraphic images of the disintegrating tablet in vivo. Second, the use of a four-pinhole collimator to acquire multiple views of the tablet resulted in high count rates and reduced acquisition times of the scintigraphic images. Third, the magnification of the scintigraphic images achieved by pinhole collimation led to significant improvement in resolution. Fourth, the radioinuclide was incorporated into the granulation so that the whole mass of the tablet was uniformly labeled with high levels of activity. This technique allowed the continuous monitoring of the disintegration process of tablets in vivo in experimental animals. Multiple pinhole collimation and the labeling process permitted the acquisition of quality scintigraphic images of the labeled tablet every 30 sec. The resolution of the method was tested in vitro and in vivo

  18. Scintigraphic myocardial imaging with sup(99m)Tc-labelled pyrophosphate of experimentally produced cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Mazurova, Y.; Bradna, P.

    1981-12-01

    Scintigraphic examination of the myocardium using sup(99m)Tc-labelled pyrophosphate was carried out in 10 dogs with experimentally produced cardiomyopathy. This was brought by introvenous administration of high doses of adrenalin and theophylline. The scan was positive in 8 out of 10 dogs. Hot foci were very extensive. The degree of accumulation was however low (2+). Histological examination of the myocardium using the light microscope showed only scarcely distinguishable damage to the tissue without the presence of necrosis. ECG examinations were normal in all cases. By means of sup(99m)Tc-labelled pyrophosphate even very small myocardial disorders can thus be detected. This fact may be of clinical importance for an early diagnosis of heart lesions.

  19. Scintigraphic study of gastric emptying with colloidal tin

    International Nuclear Information System (INIS)

    Rodríguez Paleo, Lester; Nuez Vilar, Maricela; Machado Lois, Marisel; López González, María Karla; Torres Leyva, Oscar; Izquierdo Izquierdo, Yimel; García González, Idelsy; Conesa Gonzalez, Ana Ibis

    2016-01-01

    Gastroparesis is defined as a delay in gastric emptying in the absence of mechanical obstruction, associated with symptoms such as nausea and / or vomiting, feeling of postprandial gastric fullness, early satiety or epigastric pain for more than 3 months. The gold standard in the diagnosis of delayed gastric emptying scintigraphy is gastric emptying and radiopharmaceutical has been used more 99m Tc-sulfur colloid not available in the country. In order to evaluate the usefulness of colloidal tin in the scintigraphic gastric emptying study, a descriptive study was conducted in 64 patients over 18 years using as radiopharmaceutical 99m Tc-Sn colloid. 31% of patients had symptoms. The emptying time was normal in 50 cases and the association of gastroparesis symptoms was observed in 20 (15 diabetic and 5 non-diabetic), 9 patients had a delayed emptying, but reported no symptoms. Gastroparesis was more frequent in women than in men (35% versus 21%). 21% of patients had a moderate delayed gastric emptying. Conclusions: The results obtained with 99m Tc-Sn colloid are comparable to those reported by other authors using 99m Tc-SC in the scintigraphic assessment of gastric emptying. (author)

  20. Scintigraphic portrayal of β receptors in the heart

    International Nuclear Information System (INIS)

    Sisson, J.C.; Wieland, D.M.; Koeppe, R.A.; Normolle, D.; Frey, K.A.; Bolgos, G.; Johnson, J.; Van Dort, M.E.; Gildersleeve, D.L.

    1991-01-01

    Myocardial β adrenergic receptors play important roles in physiology and disease, but the receptors have not before been portrayed. The β antagonist, iodocyanopindolol (ICYP), was used to develop a scintigraphic method for depicting the receptors in the living heart. Labeled with 125I, ICYP bound firmly to β receptors in the rat heart; the data conformed to a mathematical model. In vivo saturation kinetics indicated binding sites with two affinities. Inhibition of ICYP binding by beta antagonists of different potency and different selectivity for β-1 and β-2 receptors produced the expected pharmacologic effects. Inhibition by lipophilic and hydrophilic antagonists gave no evidence that ICYP was appreciably bound to internalized receptors. Fractional binding by tracer quantities of (-) ICYP and ± ICYP demonstrated stereospecificity. Labeled with 123I, ICYP bound to the hearts of intact dogs so that scintigraphic tomographs depicted ventricular myocardium. Small doses of beta antagonists selectively reduced the binding of ICYP to lung enabling better visualization of the heart. Thus, 123I-ICYP appears to portray the beta receptors in the living heart, and the characteristics of binding permit the development of mathematical models and lay the basis for quantifying this receptor binding

  1. Quantitative phase imaging and differential interference contrast imaging for biological TEM

    International Nuclear Information System (INIS)

    Allman, B.E.; McMahon, P.J.; Barone-Nugent, E.D.; Nugent, E.D.

    2002-01-01

    Full text: Phase microscopy is a central technique in science. An experienced microscopist uses this effect to visualise (edge) structure within transparent samples by slightly defocusing the microscope. Although widespread in optical microscopy, phase contrast transmission electron microscopy (TEM) has not been widely adopted. TEM for biological specimens has largely relied on staining techniques to yield sufficient contrast. We show here a simple method for quantitative TEM phase microscopy that quantifies this phase contrast effect. Starting with conventional, digital, bright field images of the sample, our algorithm provides quantitative phase information independent of the sample's bright field intensity image. We present TEM phase images of a range of stained and unstained, biological and material science specimens. This independent phase and intensity information is then used to emulate a range of phase visualisation images familiar to optical microscopy, e.g. differential interference contrast. The phase images contain features not visible with the other imaging modalities. Further, if the TEM samples have been prepared on a microtome to a uniform thickness, the phase information can be converted into refractive index structure of the specimen. Copyright (2002) Australian Society for Electron Microscopy Inc

  2. Application of phase contrast imaging to mammography

    International Nuclear Information System (INIS)

    Tohyama, Keiko; Yamada, Katsuhiko; Katafuchi, Tetsuro; Matsuo, Satoru; Morishita, Junji

    2005-01-01

    Phase contrast images were obtained experimentally by using a customized mammography unit with a nominal focal spot size of 100 μm and variable source-to-image distances of up to 1.5 m. The purpose of this study was to examine the applicability and potential usefulness of phase contrast imaging for mammography. A mammography phantom (ACR156 RMI phantom) was imaged, and its visibility was examined. The optical density of the phantom images was adjusted to approximately 1.3 for both the contact and phase contrast images. Forty-one observers (18 medical doctors and 23 radiological technologists) participated in visual evaluation of the images. Results showed that, in comparison with the images of contact mammography, the phantom images of phase contrast imaging demonstrated statistically significantly superior visibility for fibers, clustered micro-calcifications, and masses. Therefore, phase contrast imaging obtained by using the customized mammography unit would be useful for improving diagnostic accuracy in mammography. (author)

  3. Parallel imaging with phase scrambling.

    Science.gov (United States)

    Zaitsev, Maxim; Schultz, Gerrit; Hennig, Juergen; Gruetter, Rolf; Gallichan, Daniel

    2015-04-01

    Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. Quadratic phase is imparted to the image to spread the signals in k-space (aka phase scrambling). By rewriting the Fourier transform as a convolution operation, a window can be introduced to the convolved chirp function, allowing a low-resolution image to be reconstructed from phase-scrambled data without prominent aliasing. This image (for each RF channel) can be used to derive coil sensitivities to drive existing parallel imaging techniques. As a proof of concept, the quadratic phase was applied by introducing an offset to the x(2) - y(2) shim and the data were reconstructed using adapted versions of the image space-based sensitivity encoding and GeneRalized Autocalibrating Partially Parallel Acquisitions algorithms. The method is demonstrated in a phantom (1 × 2, 1 × 3, and 2 × 2 acceleration) and in vivo (2 × 2 acceleration) using a 3D gradient echo acquisition. Phase scrambling can be used to perform parallel imaging acceleration without acquisition of separate coil calibration data, demonstrated here for a 3D-Cartesian trajectory. Further research is required to prove the applicability to other 2D and 3D sampling schemes. © 2014 Wiley Periodicals, Inc.

  4. Scintigraphic appearance of focal fatty infiltration of the liver using single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kudo, M.; Hirasa, M.; Ibuki, Y.

    1984-01-01

    Fatty infiltration of the liver had been considered to assume a uniform distribution until quite recently. However, the development of X-ray computed tomography (XCT) and the ultrasound (US) has proven that fatty infiltration of the liver may sometimes assume a nonuniform distribution (focal fatty infiltration (FFI)). This investigation was undertaken to evaluate the scintigraphic appearance of FFI using single-photon emission computed tomography (SPECT) with a GE Maxicamera 400T. Radionuclide images including SPECT were evaluated in 12 cases with FFI which were diagnosed by XCT and US. Most of them were histrogically confirmed to be positive fatty infiltration in the liver. The results were as follows. The fatty infiltrated area was visualized as a hot spot in one case, a defect in 2 cases, a low uptake in one case and a normal uptake in 8 cases. Radionuclide imaging of FFI shows a large variety of findings and it suggests that Kupffer cell function varies with the causes or stage of fatty infiltration. And one can understand the pathological state of FFI from a viewpoint of Kupffer cell function only by radionuclide imaging including SPECT, which is very useful to compare the images with XCT images

  5. Compton scatter correction for planner scintigraphic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vaan Steelandt, E; Dobbeleir, A; Vanregemorter, J [Algemeen Ziekenhuis Middelheim, Antwerp (Belgium). Dept. of Nuclear Medicine and Radiotherapy

    1995-12-01

    A major problem in nuclear medicine is the image degradation due to Compton scatter in the patient. Photons emitted by the radioactive tracer scatter in collision with electrons of the surrounding tissue. Due to the resulting loss of energy and change in direction, the scattered photons induce an object dependant background on the images. This results in a degradation of the contrast of warm and cold lesions. Although theoretically interesting, most of the techniques proposed in literature like the use of symmetrical photopeaks can not be implemented on the commonly used gamma camera due to the energy/linearity/sensitivity corrections applied in the detector. A method for a single energy isotope based on existing methods with adjustments towards daily practice and clinical situations is proposed. It is assumed that the scatter image, recorded from photons collected within a scatter window adjacent to the photo peak, is a reasonable close approximation of the true scatter component of the image reconstructed from the photo peak window. A fraction `k` of the image using the scatter window is subtracted from the image recorded in the photo peak window to produce the compensated image. The principal matter of the method is the right value for the factor `k`, which is determined in a mathematical way and confirmed by experiments. To determine `k`, different kinds of scatter media are used and are positioned in different ways in order to simulate a clinical situation. For a secondary energy window from 100 to 124 keV below a photo peak window from 126 to 154 keV, a value of 0.7 is found. This value has been verified using both an antropomorph thyroid phantom and the Rollo contrast phantom.

  6. Dynamic scintigraphic studies after oesophageal reconstruction

    International Nuclear Information System (INIS)

    Maliska, C.M.; Maliska, C.; Pinto, E.; Castro, L.; Fonseca, L.B.E; Miranda, M.

    1997-01-01

    Full text: We have studied the oesophageal transit and gastric emptying in the monitoring of the effect of oesophageal reconstruction surgery. Oncologic patients were evaluated after oesophageal reconstruction surgery with gastric (14 patients) or colonic (5 patients) tube and they were compared with 15 healthy volunteers, using scintigraphic method with liquid food (S-colloid-Tc99m). In the oesophageal transit studies there were no significant statistical differences among the three groups, when we have just considered to two superior (of the three) segments, as oesophagus, showing that the distal neo-tube works just like the stomach of normal volunteers

  7. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  8. Benchtop phase-contrast X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gundogdu, O. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)], E-mail: o.gundogdu@surrey.ac.uk; Nirgianaki, E.; Che Ismail, E.; Jenneson, P.M.; Bradley, D.A. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2007-12-15

    Clinical radiography has traditionally been based on contrast obtained from absorption when X-rays pass through the body. The contrast obtained from traditional radiography can be rather poor, particularly when it comes to soft tissue. A wide range of media of interest in materials science, biology and medicine exhibit very weak absorption contrast, but they nevertheless produce significant phase shifts with X-rays. The use of phase information for imaging purposes is therefore an attractive prospect. Some of the X-ray phase-contrast imaging methods require highly monochromatic plane wave radiation and sophisticated X-ray optics. However, the propagation-based phase-contrast imaging method adapted in this paper is a relatively simple method to implement, essentially requiring only a microfocal X-ray tube and electronic detection. In this paper, we present imaging results obtained from two different benchtop X-ray sources employing the free space propagation method. X-ray phase-contrast imaging provides higher contrast in many samples, including biological tissues that have negligible absorption contrast.

  9. Optical image transformation and encryption by phase-retrieval-based double random-phase encoding and compressive ghost imaging

    Science.gov (United States)

    Yuan, Sheng; Yang, Yangrui; Liu, Xuemei; Zhou, Xin; Wei, Zhenzhuo

    2018-01-01

    An optical image transformation and encryption scheme is proposed based on double random-phase encoding (DRPE) and compressive ghost imaging (CGI) techniques. In this scheme, a secret image is first transformed into a binary image with the phase-retrieval-based DRPE technique, and then encoded by a series of random amplitude patterns according to the ghost imaging (GI) principle. Compressive sensing, corrosion and expansion operations are implemented to retrieve the secret image in the decryption process. This encryption scheme takes the advantage of complementary capabilities offered by the phase-retrieval-based DRPE and GI-based encryption techniques. That is the phase-retrieval-based DRPE is used to overcome the blurring defect of the decrypted image in the GI-based encryption, and the CGI not only reduces the data amount of the ciphertext, but also enhances the security of DRPE. Computer simulation results are presented to verify the performance of the proposed encryption scheme.

  10. Scintigraphic Methods to Evaluate Alterations of Gastric and Esophageal Functions in Female Obesity

    Directory of Open Access Journals (Sweden)

    Özgür Ömür

    2014-02-01

    Full Text Available Objective: Altered gastrointestinal function has frequently been observed in obese patients. The aim of this study was to investigate the frequency of gastro-esophageal reflux (GER and to determine the alterations of gastric emptying and esophageal transit by scintigraphic methods in obese patients. Methods: Scintigraphic studies of 50 obese female non-diabetic patients who had not received any treatment for weight control were retrospectively reviewed. Mean Body Mass Index (BMI was 34.96±3.04 kg/m² (range:32-39 kg/m². All subjects were submitted to scintigraphic evaluation of esophageal transit, gastro-esophageal reflux, gastric emptying and presence of Helicobacter pylori infection. The data of obese patients were compared with those of sex-age matched 30 non-obese cases who were selected from our clinical archive. Results: In obese group, seventeen (34% patients were found to be GER positive scintigraphically; mean gastric emptying time (t½ was 59.18±30.8 min and the mean esophageal transit time was 8.9±7.2 s. Frequency of positive GER scintigraphy and the mean value of esophageal transit time were significantly higher in obese patients than non-obese control subjects. Gastric emptying time and esophageal transit time values were significantly longer in GER positive obese patients than GER negative ones. There was no statistically significant difference in the frequency of positive C14 urea breath test between obese and non-obese subjects and there were also no statistically significant correlations between BMI, GER, esophageal transit time and gastric emptying time. Conclusion: In our study, 42 of the 50 obese patients had esophago-gastric motility alterations. The significance of these alterations in obesity is not fully understood, but it is believed that these changes could be because of potential contributing factors in the development or maintenance of obesity or changes in eating habits

  11. The 'fragmented' scintigraphic lung pattern in pulmonary lymphangitic carcinomatosis secondary to breast cancer.

    Science.gov (United States)

    Vattimo, A V; Burroni, L; Bertelli, P; Vella, A; Volterrani, D

    1998-01-01

    Pulmonary lymphangitic carcinomatosis (PLC) is an unusual presentation of diffuse infiltrative lung disease. In this report we present two cases secondary to breast cancer; the diagnosis was made by means of transbronchial lung biopsy or postmortem examination. The goal of this study was to analyze the scintigraphic pattern of pulmonary perfusion performed with technetium-99m macroaggregated albumin (99mTc-MAA) in the hope of achieving improved recognition of PLC and its subsequent diagnosis. Upon admission, both patients underwent routine clinical exams followed by chest X-rays. The second patient also underwent CT examination, and both were ultimately examined using pulmonary perfusion scintigraphy with 99mTc-MAA. In the various exams performed, the most reliable and easily identified diagnostic finding turned out to be a characteristic 'fragmented' lung pattern revealed with the perfusion lung scan. Unfortunately, in both cases the patients' conditions rapidly worsened and death occurred shortly following scintigraphy. We were able to conclude that the recognition of the mentioned fragmented scintigraphic lung pattern may be useful in suspected PLC, whereas the nonspecific clinical presentation of this pathology makes diagnosis extremely difficult, with the most significant results being achieved through a comparison of scintigraphic and high resolution CT data.

  12. Scintigraphic evaluation of gastroesophageal reflux

    International Nuclear Information System (INIS)

    Malmud, L.S.; Fisher, R.S.

    1983-01-01

    When patients have symptomatic gastroesophageal reflux disease, their symptoms usually respond to conventional therapeutic measures. In some patients, however, the symptoms may persist despite the application of standard treatment regimens. It is in these instances that the clinician may employ extensive diagnostic tests to determine the cause of the patient's complaints. Because the introduction of gastroesophageal scintigraphy, a number of other techniques were employed to evaluate gastroesophageal reflux. These include barium esophagography, barium cineesophagography; endoscopy; esophageal mucosal biopsy; esophageal manometry; the acid-clearance test; and acid-reflux testing. Each of the nonscintigraphic techniques has a limitation either in its sensitivity or in the requirement for endogastric intubation. In addition, with the exception of the scintigraphic method, none of the tests permits quantitation of reflux

  13. Scintigraphic visualization of bacterial translocation in experimental strangulated intestinal obstruction

    International Nuclear Information System (INIS)

    Galeev, Yu.M.; Popov, M.V.; Salato, O.V.; Lishmanov, Yu.B.; Grigorev, E.G.; Aparcin, K.A.

    2009-01-01

    The purpose of this study was to obtain scintigraphic images depicting translocation of 99m Tc-labelled Escherichia coli bacteria through the intestinal barrier and to quantify this process using methods of nuclear medicine. Thirty male Wistar rats (including 20 rats with modelled strangulated intestinal obstruction and 10 healthy rats) were used for bacterial scintigraphy. 99m Tc-labelled E. coli bacteria ( 99m Ts-E. coli) with an activity of 7.4-11.1 MBq were administered into a section of the small intestine. Scintigraphic visualization of bacterial translocation into organs and tissues of laboratory animals was recorded in dynamic (240 min) and static (15 min) modes. The number of labelled bacteria, which migrated through the intestinal barrier, was quantified by calculating the translocation index (TI). Control indicated no translocation of 99m Ts-E. coli administered into the intestine through the parietes of the small intestine's distal part in healthy animals. Animals with strangulated obstruction demonstrated different migration strength and routes of labelled bacteria from strangulated and superior to strangulation sections of the small intestine. 99m Ts-E. coli migrated from the strangulated loop into the peritoneal cavity later causing systemic bacteraemia through peritoneal resorption. The section of the small intestine, which was superior to the strangulation, demonstrated migration of labelled bacteria first into the portal and then into the systemic circulation. The strangulated section of the small intestine was the main source of bacteria dissemination since the number of labelled bacteria, which migrated from this section significantly, exceeded that of the area superior to the strangulation section of the small intestine (p = 0.0003). Bacterial scintigraphy demonstrated the possibility of visualizing migration routes of labelled bacteria and quantifying their translocation through the intestinal barrier. This approach to study bacterial

  14. Isotropic differential phase contrast microscopy for quantitative phase bio-imaging.

    Science.gov (United States)

    Chen, Hsi-Hsun; Lin, Yu-Zi; Luo, Yuan

    2018-05-16

    Quantitative phase imaging (QPI) has been investigated to retrieve optical phase information of an object and applied to biological microscopy and related medical studies. In recent examples, differential phase contrast (DPC) microscopy can recover phase image of thin sample under multi-axis intensity measurements in wide-field scheme. Unlike conventional DPC, based on theoretical approach under partially coherent condition, we propose a new method to achieve isotropic differential phase contrast (iDPC) with high accuracy and stability for phase recovery in simple and high-speed fashion. The iDPC is simply implemented with a partially coherent microscopy and a programmable thin-film transistor (TFT) shield to digitally modulate structured illumination patterns for QPI. In this article, simulation results show consistency of our theoretical approach for iDPC under partial coherence. In addition, we further demonstrate experiments of quantitative phase images of a standard micro-lens array, as well as label-free live human cell samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Scintigraphic detection of thrombi using indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Ikeoka, Kiyomitsu; Todo, Yasuhiro; Konishiike, Atsushi; Fujisue, Ryu; Ohyanagi, Mitsumasa; Yasutomi, Nagao; Tanimoto, Masaho; Kawai, Yoshitaka; Iwasaki, Tadaaki

    1985-01-01

    Intracardiac and arterial thrombi were examined by scintigraphy using In-111-oxine labeled autologous platelets. 1. In 22 cases of myocardial infarction including six with ventricular aneurysms, four had positive findings of thrombi on imaging and detected also by echocardiography. All four had ventricular aneurysms. The so-called ''moya-moya'' echoes (fuzzy echoes) were demonstrated in two of these four cases. 2. We encountered two cases with positive findings on imaging in 13 with mitral valve disease. These two had systemic embolic episodes after scintigraphic examination. ''Moya-moya'' echoes were detected in the left atrial cavity in four with negative findings on imaging. 3. Positive images were obtained in two of three with acute arterial occlusive disease, and in both cases platelet deposition was observed in the proximal site of obstruction. Though thrombectomy was performed for one of these two cases, no thrombus was detected at the site of platelet deposition. After one month, re-examination revealed only negative findings in all sites in both these patients. 4. In the six cases of aortic aneurysm, three had platelet deposition within their aneurysms, and surgery was performed for these positive cases, but one of them had no thrombus. 5. Positive images were obtained in only one of seven patients with chronic arterial occlusive disease. 6. Coagulation tests and platelet studies were investigated for patients with positive or negative platelet scans. Only the data of the thrombo-test showed a significant difference (97 +- 9 % vs 23 +- 7 %, p < 0.001). Three cases of positive imaging became negative after anticoagulant therapy. 7. We tried ECT for eight cases 24 hours after injection of In-111-oxine labeled platelets. Three cases showed clear images of thrombi, while the planar images could not detect them at an early stage. Therefore, we propose that ECT can be a useful technique for diagnosing intracardiac thrombi in early stage. (author)

  16. Scintigraphic diagnosis of experimentally induced pericarditis in dogs using 99sup(m)Tc-labelled pyrophosphate

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubizek, J.; Simon, J.; Veverkova, O.; Karlova Universita, Hradec Kralove

    1981-01-01

    In the present paper the possibilities of scintigraphic diagnosis of experimental pericarditis are discussed. Pericarditis was induced by either talc or formaldehyde intrapericardially. In all animals the administration of talc as well as formaldehyde produced inflammatory changes which were more serious after formaldehyde. The scan of the talc pericarditis was carried out on the 7th day after operation and of the formaldehyde pericarditis on the 3rd, 7th and 14th day. No positive scintigraphic finding was made in any of the experimental animals, apart from a massive incorporation in the operation scars. The counting of radioactive impulses after the exstirpation of the tissue samples confirmed the scintigraphic findings. Statistical evaluation did not reveal any essential difference between the accumulation of the radiopharmaceutical into the pericarditis as well as into the pericardial bag in comparison with the control animals. Although our model does not exactly reflect the situation of patients suffering from pericarditis it may be assumed that pyrophosphate scintigraphy is not suitable for the diagnosis of acute pericarditis in clinical practice. (orig.) [de

  17. Serendipity in scintigraphic gastrointestinal bleeding studies

    International Nuclear Information System (INIS)

    Goergen, T.G.

    1983-01-01

    A retrospective review of 80 scintigraphic bleeding studies performed with Tc-99m sulfur colloid or Tc-99m labeled red blood cells showed five cases where there were abnormal findings not related to bleeding. In some cases, the abnormalities were initially confused with bleeding or could obscure an area of bleeding, while in other cases, the abnormalities represented additional clinical information. These included bone marrow replacement related to tumor and radiation therapy, hyperemia related to a uterine leiomyoma and a diverticular abscess, and a dilated abdominal aorta (aneurysm). Recognition of such abnormalities should prevent an erroneous diagnosis and the additional information may be of clinical value

  18. Phase retrieval for X-ray in-line phase contrast imaging

    International Nuclear Information System (INIS)

    Scattarella, F.; Bellotti, R.; Tangaro, S.; Gargano, G.; Giannini, C.

    2011-01-01

    A review article about phase retrieval problem in X-ray phase contrast imaging is presented. A simple theoretical framework of Fresnel diffraction imaging by X-rays is introduced. A review of the most important methods for phase retrieval in free-propagation-based X-ray imaging and a new method developed by our collaboration are shown. The proposed algorithm, Combined Mixed Approach (CMA) is based on a mixed transfer function and transport of intensity approach, and it requires at most an initial approximate estimate of the average phase shift introduced by the object as prior knowledge. The accuracy with which this initial estimate is known determines the convenience speed of algorithm. The new proposed algorithm is based on the retrieval of both the object phase and its complex conjugate. The results obtained by the algorithm on simulated data have shown that the obtained reconstructed phase maps are characterized by particularly low normalized mean square errors. The algorithm was also tested on noisy experimental phase contrast data, showing a good efficiency in recovering phase information and enhancing the visibility of details inside soft tissues.

  19. Survey of 26 suprarenal scintigraphs on Cushing's syndrome patients

    International Nuclear Information System (INIS)

    Venot, A.; Luton, J.P.; Roucayrol, J.C.; Bricaire, H.

    On the basis of the results of 26 Cushing's syndrome examinations some new scintigraphic aspects are described, suprarenal scintigraphy is compared with retroperitoneal insufflation, its value in the observation of a medical treatment of Cushing's disease is demonstrated and finally some preliminary results are given on the application in the same pathological context, of 75 Se-6-selenocholesterol which was compared with 131 I-19-iodocholesterol [fr

  20. 99m-Tc-IDA scintigraphic demonstrability of biliary elements and liver function tests in hepatobiliary diseases

    International Nuclear Information System (INIS)

    Kim, C.Y.; Bahk, Y.W.

    1982-01-01

    In the present communication, the results will be reported on a clinical study of how well scintigraphic visualization of the hepatobiliary elements and several commonly used clinical liver function tests correlate each other in various diseases of the hepatobiliary system. The demonstrability of the biliary tract, gallblader (GB) and duodenum was rather closely paralleled to serum bilirubin level and less closely to alkaline phosphatase and rather poorly to SGOT and SGPT. The biliary tree could not be visualized scintigraphically when bilirubin exceeded 10 mg/dl

  1. Future of X-ray phase imaging in medical imaging technology

    International Nuclear Information System (INIS)

    Momose, Atsushi

    2007-01-01

    Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

  2. Scintigraphic Small Intestinal Transit Time and Defaecography in Patients with J-Pouch

    Directory of Open Access Journals (Sweden)

    Mie Dilling Kjaer

    2015-10-01

    Full Text Available Objective methods for examination of pouch function are warranted for a better understanding of the functional result and treatment of dysfunction. The objective of this study was to evaluate the results of scintigraphic intestinal transit time and defaecography compared to the results of pouch function, mucosal condition and a questionnaire on quality of life (QoL. This cross-sectional study included 21 patients. Scintigraphic transit time and defaecography was determined with the use of Tc-99m. Pouch function was assessed by number of bowel movements, pouch volume, and continence. Pouch mucosal condition was evaluated by endoscopy and histology. Median transit time was 189 min (105–365. Median ejection fraction at defaecography (EF was 49% (3–77 and 62% (17–98 after first and second defecation. Median pouch volume was 223 mL (100–360. A median daily stool frequency of nine (4–25 was reported and three (14% patients suffered from daytime incontinence. No patients had symptomatic or endoscopic pouchitis; however, the histology showed unspecific inflammation in 19 (90% patients. There was no correlation between transit time, evacuation fraction (EF and pouch function in univariate analysis. However, we found a high body mass index (BMI and a low bowel movement frequency to be associated with a longer transit time by multivariate analysis. Scintigraphic determination of transit time and defaecography are feasible methods in patients with ileal pouch anal anastomosis, but the clinical relevance is yet doubtful.

  3. X-ray phase-contrast imaging

    Science.gov (United States)

    Endrizzi, Marco

    2018-01-01

    X-ray imaging is a standard tool for the non-destructive inspection of the internal structure of samples. It finds application in a vast diversity of fields: medicine, biology, many engineering disciplines, palaeontology and earth sciences are just few examples. The fundamental principle underpinning the image formation have remained the same for over a century: the X-rays traversing the sample are subjected to different amount of absorption in different parts of the sample. By means of phase-sensitive techniques it is possible to generate contrast also in relation to the phase shifts imparted by the sample and to extend the capabilities of X-ray imaging to those details that lack enough absorption contrast to be visualised in conventional radiography. A general overview of X-ray phase contrast imaging techniques is presented in this review, along with more recent advances in this fast evolving field and some examples of applications.

  4. Quantitative phase imaging of arthropods

    Science.gov (United States)

    Sridharan, Shamira; Katz, Aron; Soto-Adames, Felipe; Popescu, Gabriel

    2015-11-01

    Classification of arthropods is performed by characterization of fine features such as setae and cuticles. An unstained whole arthropod specimen mounted on a slide can be preserved for many decades, but is difficult to study since current methods require sample manipulation or tedious image processing. Spatial light interference microscopy (SLIM) is a quantitative phase imaging (QPI) technique that is an add-on module to a commercial phase contrast microscope. We use SLIM to image a whole organism springtail Ceratophysella denticulata mounted on a slide. This is the first time, to our knowledge, that an entire organism has been imaged using QPI. We also demonstrate the ability of SLIM to image fine structures in addition to providing quantitative data that cannot be obtained by traditional bright field microscopy.

  5. Evaluation of the use of technetium Tc 99m diethylenetriamine pentaacetic acid and technetium Tc 99m dimercaptosuccinic acid for scintigraphic imaging of the kidneys in green iguanas (Iguana iguana).

    Science.gov (United States)

    Greer, Leah L; Daniel, Gregory B; Shearn-Bochsler, Valerie I; Ramsay, Edward C

    2005-01-01

    To evaluate the use of scintigraphy involving technetium Tc 99m diethylenetriamine pentaacetic acid ((99m)Tc-DTPA) or technetium Tc 99m dimercaptosuccinic acid ((99m)Tc-DMSA) for the determination of kidney morphology and function in green iguanas (Iguana iguana). 10 healthy iguanas weighing >1.6 kg. Renal scintigraphy was performed by use of (99m)Tc-DTPA in 6 of the iguanas and by use of (99m)Tc-DMSA in all 10 iguanas. After the injection of (99m)Tc-DMSA, scans were performed for each iguana at intervals during a 20-hour period. Renal biopsies were performed in all 10 iguanas after the final scintigraphic evaluation. In iguanas, the use of (99m)Tc-DTPA for renal scintigraphy was nondiagnostic because of serum protein binding and poor renal uptake of the isotope; mean +/- SD (99m)Tc-DTPA bound to serum proteins was 48.9 +/- 9.9%. Renal uptake of (99m)Tc-DMSA produced distinct visualization of both kidneys. Renal uptake and soft tissue clearance of (99m)Tc-DMSA increased over the 20-hour imaging period; mean +/- SD renal uptake of (99m)Tc-DMSA was 11.31 +/- 3.06% at 20 hours. In each of the 10 iguanas, ultrasonographic and histologic examinations of biopsy specimens from both kidneys revealed no abnormalities. Results indicate that the kidneys of iguanas can be evaluated scintigraphically by use of (99m)Tc-DMSA; this technique may be potentially useful for the diagnosis of renal failure in iguanas.

  6. Gallium-68 DOTA-TATE Positron Emission Tomography/Computed Tomography: Scintigraphic Changes of Adrenal Glands Following Management of Ectopic Cushing's Syndrome by Steroidogenesis Inhibitors

    International Nuclear Information System (INIS)

    Huang, Yu-Ting; Aziz, Shaikh Irfan; Kumar, Aravind S. Ravi

    2014-01-01

    In the era of emerging functional imaging techniques, an understanding of the effects of hormonal therapies on the scintigraphic appearance of endocrine organs is desirable to minimize the erroneous scan interpretation. The mechanisms by which changes in the scintigraphic appearance of endocrine organs occur however sometimes remain ambiguous. This case demonstrates the gallium-68 (Ga-68) DOTA-TATE positron emission tomography/computed tomography (CT) appearance of adrenal glands following management with steroidogenesis inhibitors. The potential mechanisms underlying this change are discussed. A 17-year-old boy with adrenocorticotropic hormone (ACTH) dependent Cushing's syndrome secondary to ectopic ACTH secretion underwent pre- and post-metyrapone and dexamethasone treatment Ga-68 DOTA-TATE scans 4 months apart. Pretreatment, both adrenals demonstrated normal symmetrical prominent Ga-68 DOTA-TATE uptake and normal CT appearance. The posttherapy scan revealed marked symmetrical suppression of Ga-68 DOTA-TATE uptake, but with bilateral adrenal hypertrophy on CT

  7. Scintigraphic acquisition entropy (2). A new approach in the quality control of the scintillation camera performances

    International Nuclear Information System (INIS)

    Elloumi, I.; Bouhdima, M.S.

    2002-01-01

    A new approach in the survey of the performances of gamma camera based on the entropy associated to the scintigraphic acquisition is presented. We take into account the sensitivity, the variation of the collimator response in function of the depth, the uncertainty on the number of counts, the multiplex effect and the spatial uncertainty. This entropy function is expressed in function of all the acquisition parameters: intrinsic crystal resolution, collimator characteristics, emitter object parameters and the source activity. The application of this method to the study of the influence of the collimation shows that the entropy associated to a collimator permits a best appreciation of the quality of the acquisition and therefore a better analysis of collimator performances. Likewise, the evolution of the entropy associated to the acquisition of a uniform source image is in agreement with the variation of the quality of image histogram. One shows, thus, that nor the spatial resolution, nor the sensitivity and nor the signal to noise ratio are able detect a variation of the image quality, when analysed one by one. (author)

  8. Scintigraphic small intestinal transit time and defaecography in patients with J-pouch

    DEFF Research Database (Denmark)

    Kjær, Mie Dilling; Simonsen, Jane Angel; Hvidsten, Svend

    2015-01-01

    Objective methods for examination of pouch function are warranted for a better understanding of the functional result and treatment of dysfunction. The objective of this study was to evaluate the results of scintigraphic intestinal transit time and defaecography compared to the results of pouch...... function, mucosal condition and a questionnaire on quality of life (QoL). This cross-sectional study included 21 patients. Scintigraphic transit time and defaecography was determined with the use of Tc-99m. Pouch function was assessed by number of bowel movements, pouch volume, and continence. Pouch...... mucosal condition was evaluated by endoscopy and histology. Median transit time was 189 min (105–365). Median ejection fraction at defaecography (EF) was 49% (3–77) and 62% (17–98) after first and second defecation. Median pouch volume was 223 mL (100–360). A median daily stool frequency of nine (4...

  9. A proposal to study the esophageal transit by biomagnetic and scintigraphic study

    International Nuclear Information System (INIS)

    Daghastanli, N.A.; Braga, F.J.H.N.; Baffa, O.

    1996-01-01

    The initial results for a new apparatus to study the esophageal transit time is studied in asymptomatic persons for a yogurt bolus (10 ml). The bolus is uniformly labeled with 5 g of ferrite powder (biomagnetic study, B) or 350 MBq of 99m Tc (scintigraphic study, C). For the B study the detection is made by means two pair of coils in opposite phase excited by a 10 k Hz sinusoidal voltage. The signal response is obtained when the bolus traverses the coils placed on the regions-of-interest (ROIs) of the esophagus (furcula, F and xiphoid process, X) and produces a signal voltage that is measured by a lock-in amplifier Stanford SR530. For C studies an Orbiter Siemens scintillation camera is used linked to a computer. The data analysis shows a (4.1±0.7)s in B studies and (3.7±0.9)s in C studies (R=0.6, P<0.07)

  10. A comparison of methods of assessment of scintigraphic colon transit.

    Science.gov (United States)

    Freedman, Patricia Noel; Goldberg, Paul A; Fataar, Abdul Basier; Mann, Michael M

    2006-06-01

    There is no standard method of analysis of scintigraphic colonic transit investigation. This study was designed to compare 4 techniques. Sixteen subjects (median age, 37.5 y; range, 21-61 y), who had sustained a spinal cord injury more than a year before the study, were given a pancake labeled with 10-18 MBq of (111)In bound to resin beads to eat. Anterior and posterior images were acquired with a gamma-camera 3 h after the meal and then 3 times a day for the next 4 d. Seven regions of interest, outlining the ascending colon, hepatic flexure, transverse colon, splenic flexure, descending colon, rectosigmoid, and total abdominal activity at each time point, were drawn on the anterior and posterior images. The counts were decay corrected and the geometric mean (GM), for each region, at each time point calculated. The GM was used to calculate the percentage of the initial total abdominal activity in each region, at each time point. Colonic transit was assessed in 4 ways: (a) Three independent nuclear medicine physicians visually assessed transit on the analog images and classified subjects into 5 categories of colonic transit (rapid, intermediate, generalized delay, right-sided delay, or left-sided delay). (b) Parametric images were constructed from the percentage activity in each region at each time point. (c) The arrival and clearance times of the activity in the right and left colon were plotted as time-activity curves. (d) The geometric center of the distribution of the activity was calculated and plotted on a graph versus time. The results of these 4 methods were compared using an agreement matrix. Though simple to perform, the visual assessment was unreliable. The best agreement occurred between the parametric images and the arrival and clearance times of the activity in the right and left colon. The different methods of assessment do not produce uniform results. The best option for evaluating colonic transit appears to be a combination of the analog images

  11. Computational Phase Imaging for Biomedical Applications

    Science.gov (United States)

    Nguyen, Tan Huu

    When a sample is illuminated by an imaging field, its fingerprints are left on the amplitude and the phase of the emerging wave. Capturing the information of the wavefront grants us a deeper understanding of the optical properties of the sample, and of the light-matter interaction. While the amplitude information has been intensively studied, the use of the phase information has been less common. Because all detectors are sensitive to intensity, not phase, wavefront measurements are significantly more challenging. Deploying optical interferometry to measure phase through phase-intensity conversion, quantitative phase imaging (QPI) has recently gained tremendous success in material and life sciences. The first topic of this dissertation describes our effort to develop a new QPI setup, named transmission Spatial Light Interference Microscopy (tSLIM), that uses the twisted nematic liquid-crystal (TNLC) modulators. Compared to the established SLIM technique, tSLIM is much less expensive to build than its predecessor (SLIM) while maintaining significant performance. The tSLIM system uses parallel aligned liquid-crystal (PANLC) modulators, has a slightly smaller signal-to-noise Ratio (SNR), and a more complicated model for the image formation. However, such complexity is well addressed by computing. Most importantly, tSLIM uses TNLC modulators that are popular in display LCDs. Therefore, the total cost of the system is significantly reduced. Alongside developing new imaging modalities, we also improved current QPI imaging systems. In practice, an incident field to the sample is rarely perfectly spatially coherent, i.e., plane wave. It is generally partially coherent; i.e., it comprises of many incoherent plane waves coming from multiple directions. This illumination yields artifacts in the phase measurement results, e.g., halo and phase-underestimation. One solution is using a very bright source, e.g., a laser, which can be spatially filtered very well. However, the

  12. Gamma scintigraphic analysis of albumin flux in patients with acute respiratory distress syndrome

    International Nuclear Information System (INIS)

    Sugerman, H.J.; Tatum, J.L.; Burke, T.S.; Strash, A.M.; Glauser, F.L.

    1984-01-01

    Computerized gamma-scintigraphy provides a new method for the analysis of albumin flux in patients with pulmonary permeability edema. In this technique, 10 mCi of 99 mTc -tagged human serum albumin is administered and lung:heart radioactivity ratios are determined. This ratio remains constant unless there is a leak of albumin, when a rising ratio with time, called the ''slope index'' (SI), is seen. Thirty-five scintigraphic studies were obtained in 28 patients by means of a portable computerized gamma-camera. Thirteen of these patients had clinical evidence of the acute respiratory distress syndrome (ARDS) and six had or were recovering from left ventricular induced congestive heart failure (CHF). Five of the patients with CHF and pulmonary capillary wedge pressure (PCWP) below 30 mm Hg had normal scintigraphic studies. The patients with ARDS were found to have significantly higher SIs than patients who did not have, or had recovered from, ARDS. Positive SIs were present from 1 to 8 days following the apparent onset of ARDS in seven studies in five patients. Recovery of gas exchange was associated with a return to a normal SI in four patients. In conclusion, computerized gamma-scintigraphy was a sensitive, noninvasive tool for the detection of a pathologic increase in pulmonary protein flux. Positive scintigraphic findings were associated with significantly impaired gas exchange. The method documented that the leak of albumin in patients with ARDS may last for days but resolves with recovery

  13. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro

    1983-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy. (author)

  14. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-12-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy.

  15. Pharyngeal transit time measured by scintigraphic and biomagnetic method; Tempo de transito faringeano medido atraves dos metodos cintilografico e biomagnetico

    Energy Technology Data Exchange (ETDEWEB)

    Miquelin, C.A.; Braga, F.J.H.N.; Baffa, O. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica; Dantas, R.O.; Oliveira, R.B. [Faculdade de Medicina de Ribeirao Preto, SP (Brazil)

    1996-12-31

    A comparative evaluation between scintigraphic and biomagnetic method to measure the pharyngeal transit is presented. Three volunteers have been studied. The aliment (yogurt) was labeled with {sup 9}9{sup m} Technetium for the scintigraphic test and with ferrite for the biomagnetic one. The preliminary results indicate a difference between the values obtained, probably due to the biomagnetic detector resolution 3 refs., 2 figs., 1 tab.

  16. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    were carried out. No significant differences between results obtained by the use of one or two scintigraphic projections were found. The between-subject coefficient of variation was 14% in the lower limb experiment and 11% in the upper limb experiment. The within-subject coefficient of variation was 6......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation...... of the lower limb and a mean reduction of 0.45+/-0.10 (2 SD) after half a minute of elevation of the upper limb. We conclude that the method is precise and can be used in investigating physiologic and pathophysiologic mechanisms in relation to blood volumes of limbs not subject to research previously....

  17. Scintigraphic examinations after stent implantation in central airways

    International Nuclear Information System (INIS)

    Richter, W.S.; Kettner, B.I.; Munz, D.L.

    1998-01-01

    Endotracheal and endobronchial stent implantation has been developed as an effective treatment of benign and malignant airway stenosis and of tracheo- or bronchoesophageal fistulas. The selection of the stent type depends on the kind and site of disease. Chest X-ray and bronchoscopy are the procedures of choice for monitoring of stent position, structure, and function. However, with scintigraphic methods the effects of stent implantation on pulmonary ventilation and perfusion can be assessed non-invasively. The validation of the effect of a stent implantation on mucociliary and tussive clearance remains to be elucidated. (orig.) [de

  18. New developments in techniques for information processing in radionuclide imaging

    International Nuclear Information System (INIS)

    Di Paola, R.; Todd-Pokropek, A.E.; CEA, 91 - Orsay

    1981-01-01

    Processing of scintigraphic data has passed through different stages in the past fifteen years. After an 'euphoric' era when large off-line computer facilities were used to process very low-quality rectilinear scan pictures, a much more critical period followed the introduction of on-line minicomputer systems to acquire, process and visualize scintillation camera data. A selection of some of the available techniques that could improve the extraction of information from scintigraphic examinations in routine is presented. Tomography has been excluded. As examples, the different techniques of (a) inhomogeneity correction of camera response and (b) respiratory motion corrections are used to show one evolutionary process in the use of computer systems. Filtering has been for a long time the major area of research in scintigraphic image processing. Only very simple (usually smoothing) filters are widely distributed. Little use of more 'powerful' filters in clinical data has been made, and very few serious evaluations have been published. Nevertheless, the number of installed minicomputer and microprocessor systems is increasing rapidly, but in general performing tasks other than filtering. The reasons for this (relative) failure are examined. Some 'new' techniques of image processing are presented. The compression of scintigraphic information is important because of the expected need in the near future for handling of large numbers of static pictures as in dynamic and tomographic studies. For dynamic information processing, the present methodology has been narrowed to those techniques that permit the entire 'data space' to be manipulated (as opposed to curve fitting after region of interest definition). 'Functional' imaging was the first step in this process. 'Factor analysis' could be the next. The results obtained by various research laboratories are reviewed. (author)

  19. Scintigraphic evaluation of primary congenital hypothyroidism: results of the Greek screening program

    Energy Technology Data Exchange (ETDEWEB)

    Panoutsopoulos, G.; Ilias, I.; Batsakis, C.; Christakopoulou, I. [Dept. of Nuclear Medicine, ' ' Sotiria' ' Hospital, Athens (Greece); Mengreli, C. [Inst. of Child Health, Athens (Greece)

    2001-04-01

    The Greek screening program for primary congenital hypothyroidism was initiated in 1979. By early 2000, thyrotropin measurements had been performed in 1,976,719 newborns, using dried blood spots obtained by heel prick. Among these children, 584 were diagnosed with congenital hypothyroidism (incidence: 1/3,384 births) and were given L-thyroxine (L-T{sub 4}) replacement therapy. In order to further evaluate and classify the children as having either an aplastic (AT) or an ectopic thyroid gland (ET) or as showing thyroidal dyshormonogenesis (DN, with a nomotopic gland), scintigraphic studies were performed at the age of 2-3 years. In 413 children of this age group (including 24 subsequently diagnosed as having had transient hypothyroidism, in whom L-T{sub 4} therapy was not resumed), thyroid hormones were measured and scintigraphic studies were done after withdrawal of L-T{sub 4} replacement treatment for 3 weeks. Given the long duration of the study, we used various scintigraphic modalities. In 96 children (group A), scintigraphy was performed using technetium-99m pertechnetate ({sup 99m}TcO{sub 4}{sup -}; 18.5 MBq given i.v.) and a rectilinear scanner. Seventy-three children (group B) were studied with {sup 99m}TcO{sub 4}{sup -} (18.5 MBq given i.v.) and a gamma camera equipped with a pinhole collimator. In these groups, atropine was administered 30 min prior to the study (0.02 mg/kg i.v. or i.m.) in order to reduce the secretion of saliva from the salivary glands. Finally, in the remaining 220 children (group C) iodine-123 sodium iodide ({sup 123}I-Na) (0.74-1.85 MBq i.v.) and the same gamma camera were used. Between-group comparisons of scintigraphic findings were done with the chi square test. In 191 children from group C, thyroglobulin (Tg) was measured and in 49 children ultrasound (US) was performed (categorising the gland as AT or ET/DN). Comparison of these modalities was done with the kappa statistic. In group A, 61.5% of children had AT, 26.0% had ET and

  20. Scintigraphic examinations concerning back pain

    International Nuclear Information System (INIS)

    Mueller-Brand, J.

    1983-01-01

    Radinuclide skeletal scintigraphy is recognized as a screening method for patients with back pain. The analog scintigram is a functional image with high sensitivity and low specificity. The improvement in specificity can be achieved using computer procedures as digital imaging, smoothing, contrast enhancement and profile selection to quantitate certain properties of the scan. Three-phase-skeletal scintigraphy, 67-Ga-citrate or 111-In labeled leucocytes augement the specificity, too. (orig.)

  1. Robustness of phase retrieval methods in x-ray phase contrast imaging: A comparison

    International Nuclear Information System (INIS)

    Yan, Aimin; Wu, Xizeng; Liu, Hong

    2011-01-01

    Purpose: The robustness of the phase retrieval methods is of critical importance for limiting and reducing radiation doses involved in x-ray phase contrast imaging. This work is to compare the robustness of two phase retrieval methods by analyzing the phase maps retrieved from the experimental images of a phantom. Methods: Two phase retrieval methods were compared. One method is based on the transport of intensity equation (TIE) for phase contrast projections, and the TIE-based method is the most commonly used method for phase retrieval in the literature. The other is the recently developed attenuation-partition based (AP-based) phase retrieval method. The authors applied these two methods to experimental projection images of an air-bubble wrap phantom for retrieving the phase map of the bubble wrap. The retrieved phase maps obtained by using the two methods are compared. Results: In the wrap's phase map retrieved by using the TIE-based method, no bubble is recognizable, hence, this method failed completely for phase retrieval from these bubble wrap images. Even with the help of the Tikhonov regularization, the bubbles are still hardly visible and buried in the cluttered background in the retrieved phase map. The retrieved phase values with this method are grossly erroneous. In contrast, in the wrap's phase map retrieved by using the AP-based method, the bubbles are clearly recovered. The retrieved phase values with the AP-based method are reasonably close to the estimate based on the thickness-based measurement. The authors traced these stark performance differences of the two methods to their different techniques employed to deal with the singularity problem involved in the phase retrievals. Conclusions: This comparison shows that the conventional TIE-based phase retrieval method, regardless if Tikhonov regularization is used or not, is unstable against the noise in the wrap's projection images, while the AP-based phase retrieval method is shown in these

  2. Scintigraphic detection of metastatic melanoma using indium 111/DTPA conjugated anti-gp240 antibody (ZME-018)

    International Nuclear Information System (INIS)

    Kirkwood, J.M.; Neumann, R.D.; Zoghbi, S.S.; Ernstoff, M.S.; Cornelius, E.A.; Shaw, C.; Ziyadeh, T.; Fine, J.A.; Unger, M.W.

    1987-01-01

    We evaluated the toxicity, pharmacokinetics, and localization of a monoclonal IgG2 alpha murine anti-human melanoma (gp240) antibody (ZME-018) that recognizes a tumor-associated cell surface glycoprotein of 240,000 molecular weight present in most melanomas. The antibody was conjugated with DTPA (diethylenetriamine pentaacetic acid) and labeled by chelation of 111 In. One mg of antibody labeled with 5 mCi of 111 In was infused, together with 0 to 40 mg of cold carrier ZME-018. The blood clearance, urinary excretion, and in vivo localization were determined in 26 patients. Scintigraphic images were obtained at 24 hours and 72 hours in all patients. Mild toxicity occurred in one patient. The half-time clearance of labeled monoclonal murine antibody (MoAb) from the blood increased from 16.1 hours at an antibody dose of 1 mg to 35.9 hours at 40 mg. Males showed faster clearance from the blood than did females or a single castrated male, perhaps due to selective concentration of antibody in the testes. Nonspecific uptake in liver, spleen, bone marrow, and intestine was seen in all patients. The percentage of known metastatic foci detected increased with the total dosage of antibody, from 23% at doses less than or equal to 5 mg, to 65%, 87% and 78% for 10, 20, and 40 mg, respectively. We conclude that at doses of greater than or equal to 10 mg, ZME-018 is a safe and potentially useful agent for the scintigraphic detection of metastatic malignant melanoma

  3. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1988-03-15

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  4. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee

    1988-01-01

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  5. Single-image phase retrieval using an edge illumination X-ray phase-contrast imaging setup

    Energy Technology Data Exchange (ETDEWEB)

    Diemoz, Paul C., E-mail: p.diemoz@ucl.ac.uk; Vittoria, Fabio A. [University College London, London WC1 E6BT (United Kingdom); Research Complex at Harwell, Oxford Harwell Campus, Didcot OX11 0FA (United Kingdom); Hagen, Charlotte K.; Endrizzi, Marco [University College London, London WC1 E6BT (United Kingdom); Coan, Paola [Ludwig-Maximilians-University, Munich 81377 (Germany); Ludwig-Maximilians-University, Garching 85748 (Germany); Brun, Emmanuel [Ludwig-Maximilians-University, Garching 85748 (Germany); European Synchrotron Radiation Facility, Grenoble 38043 (France); Wagner, Ulrich H.; Rau, Christoph [Diamond Light Source, Harwell Oxford Campus, Didcot OX11 0DE (United Kingdom); Robinson, Ian K. [Research Complex at Harwell, Oxford Harwell Campus, Didcot OX11 0FA (United Kingdom); London Centre for Nanotechnology, London WC1 H0AH (United Kingdom); Bravin, Alberto [European Synchrotron Radiation Facility, Grenoble 38043 (France); Olivo, Alessandro [University College London, London WC1 E6BT (United Kingdom); Research Complex at Harwell, Oxford Harwell Campus, Didcot OX11 0FA (United Kingdom)

    2015-06-25

    A method enabling the retrieval of thickness or projected electron density of a sample from a single input image is derived theoretically and successfully demonstrated on experimental data. A method is proposed which enables the retrieval of the thickness or of the projected electron density of a sample from a single input image acquired with an edge illumination phase-contrast imaging setup. The method assumes the case of a quasi-homogeneous sample, i.e. a sample with a constant ratio between the real and imaginary parts of its complex refractive index. Compared with current methods based on combining two edge illumination images acquired in different configurations of the setup, this new approach presents advantages in terms of simplicity of acquisition procedure and shorter data collection time, which are very important especially for applications such as computed tomography and dynamical imaging. Furthermore, the fact that phase information is directly extracted, instead of its derivative, can enable a simpler image interpretation and be beneficial for subsequent processing such as segmentation. The method is first theoretically derived and its conditions of applicability defined. Quantitative accuracy in the case of homogeneous objects as well as enhanced image quality for the imaging of complex biological samples are demonstrated through experiments at two synchrotron radiation facilities. The large range of applicability, the robustness against noise and the need for only one input image suggest a high potential for investigations in various research subjects.

  6. Gastric emptying and intragastric distribution of lipids in man. A new scintigraphic method of study

    International Nuclear Information System (INIS)

    Jian, R.; Vigneron, N.; Najean, Y.; Bernier, J.J.

    1982-01-01

    We measured gastric emptying of fat and water from a solid-liquid meal in healthy volunteers using a tubeless scintigraphic method. 75 Se glycerol triether, incorporated in butter, was the lipid-phase marker, and /sup 99m/Tcm, ingested with 250 ml water, the non-lipid phase marker. In seven of these subjects we also measured the gastric emptying of solids and liquids with /sup 99m/Tc bound to cooked egg whites as the solid-phase marker and 111 In ingested with 250 ml water as the marker of the solid and aqueous phases. Emptying and intragastric repartition of each marker were measured by detection of radioactivity changes over the abdominal area using a gamma-camera. The stability and the specificity of the labeling was checked for each marker. Mean gastric emptying rate (expressed as percentage ingested marker emptied per hr) of lipids (17.4 +/- 2.4) was much lower than that of the rest of the meal (34.2 +/- 1.8) and slightly, but significantly, lower than that of solids (22.8 +/- 1.8). An intragastric layering of fat above nonlipids was observed only after the first postprandial hour and remained moderate. Thus, lipids are emptied more slowly than any other component of an ordinary meal, and this is not due only to layering of fat above water

  7. Gastric emptying and intragastric distribution of lipids in man. A new scintigraphic method of study

    Energy Technology Data Exchange (ETDEWEB)

    Jian, R.; Vigneron, N.; Najean, Y.; Bernier, J.J.

    1982-08-01

    We measured gastric emptying of fat and water from a solid-liquid meal in healthy volunteers using a tubeless scintigraphic method. /sup 75/Se glycerol triether, incorporated in butter, was the lipid-phase marker, and /sup 99m/Tcm, ingested with 250 ml water, the non-lipid phase marker. In seven of these subjects we also measured the gastric emptying of solids and liquids with /sup 99m/Tc bound to cooked egg whites as the solid-phase marker and /sup 111/In ingested with 250 ml water as the marker of the solid and aqueous phases. Emptying and intragastric repartition of each marker were measured by detection of radioactivity changes over the abdominal area using a gamma-camera. The stability and the specificity of the labeling was checked for each marker. Mean gastric emptying rate (expressed as percentage ingested marker emptied per hr) of lipids (17.4 +/- 2.4) was much lower than that of the rest of the meal (34.2 +/- 1.8) and slightly, but significantly, lower than that of solids (22.8 +/- 1.8). An intragastric layering of fat above nonlipids was observed only after the first postprandial hour and remained moderate. Thus, lipids are emptied more slowly than any other component of an ordinary meal, and this is not due only to layering of fat above water.

  8. Clinical, radiographic and scintigraphic aspects of the trapeziometacarpal osteoarthritis; Caracterizacao clinica, radiografica e cintilografica da osteoartrose trapeziometacarpiana

    Energy Technology Data Exchange (ETDEWEB)

    Kaziyama, Helena Hideko Seguchi

    1996-12-31

    Trapeziometacarpal osteoarthritis occurs mainly in women during the menopausal period. It is related to manual activities and is usually bilateral. The onset is insidious and the evolution is slow and progressive. It is characterized by of strength and pain in the basis of the thumb resulting in limitation of the use and function of the hand. The diagnosis of this condition is based on the physical examination. The manouver of compression axial-rotation of the trapezimetacarpal joint is a common positive finding. Typical findings of osteoarthritis are present in the radiological studies. Scintigraphic images have a predictive value. The early diagnosis is important to avoid the risk factors and to prevent disabilities of the hand. (author) 102 refs., 18 figs., 10 tabs.

  9. Clinical, radiographic and scintigraphic aspects of the trapeziometacarpal osteoarthritis; Caracterizacao clinica, radiografica e cintilografica da osteoartrose trapeziometacarpiana

    Energy Technology Data Exchange (ETDEWEB)

    Kaziyama, Helena Hideko Seguchi

    1997-12-31

    Trapeziometacarpal osteoarthritis occurs mainly in women during the menopausal period. It is related to manual activities and is usually bilateral. The onset is insidious and the evolution is slow and progressive. It is characterized by of strength and pain in the basis of the thumb resulting in limitation of the use and function of the hand. The diagnosis of this condition is based on the physical examination. The manouver of compression axial-rotation of the trapezimetacarpal joint is a common positive finding. Typical findings of osteoarthritis are present in the radiological studies. Scintigraphic images have a predictive value. The early diagnosis is important to avoid the risk factors and to prevent disabilities of the hand. (author) 102 refs., 18 figs., 10 tabs.

  10. Scintigraphic determination of the effect of metoclopramide and morphine on small intestinal transit time

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, E.K.; Caride, V.J.; Winchenbach, K.; Troncale, F.J.; McCallum, R.W.

    1988-01-01

    To determine if a scintigraphic method could detect pharmacologic changes in small intestinal transit time (SITT), 10 male volunteers were studied at baseline and after intravenously administered metoclopramide (10 mg) and morphine (8 mg). Five of these volunteers were studied with the hydrogen breath test method for comparison. For each of the scintigraphic studies, the volunteers were positioned supine under a large-field-of-view gamma camera after ingesting an isosmotic lactulose solution containing 99mtechnetium-diethylenetriaminepentaacetic acid (DTPA). Data were collected and stored in a computer. Both gastric emptying and SITT were determined. SITT was 81 +/- 11 min (mean +/- S.E.M.; N = 10) during baseline studies, was decreased significantly to 50 +/- 6 min (N = 10; P less than 0.01) after metoclopramide, and was increased significantly to 161 +/- 15 min (N = 8; P less than 0.01) after morphine. Baseline mean values were 86.3 +/- 15 min (N = 15) for the hydrogen breath tests, 47 +/- 8 min (N = 5) for metoclopramide, and 183 +/- 16 min (N = 5) for morphine. For gastric emptying, there was no significant difference in percentage emptying at 1 hr for baseline and metochopramide (82 +/- 5% vs. 88 +/- 4%). Morphine prolonged gastric emptying at 1 hr to 63 +/- 8%. We conclude that the scintigraphic method for measuring SITT permits accurate investigation of the pharmacologic effects on intestinal motility and, in addition, may be a useful research and clinical method for SITT determination.

  11. Scintigraphic scoring system for grading severity of gastro-esophageal reflux on 99mTc sulfur colloid gastro-esophageal reflux scintigraphy: a prospective study of 39 cases with pre and post treatment assessment

    International Nuclear Information System (INIS)

    Puranik, Ameya D.; Nair, Gopinathan; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand; Aggarwal, Rajiv

    2013-01-01

    The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99m Tc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value < 0.001. The scintigraphic scoring system had a sensitivity of 93.9% in assessing treatment response to domperidone, specificity of 83.3% i.e., 83.3% of children with no decline in scintigraphic scores show no clinical response to Domperidone. The scintigraphic scoring system had a positive predictive value of 96.9% and a negative predictive value of 71.4%. GERS with its quantitative parameters is a good investigation for assessing the severity of reflux and also for following children post-treatment. (author)

  12. Evaluation of radionuclide calibrators and scintigraphic cameras used in nuclear medicine in the Sergipe

    International Nuclear Information System (INIS)

    Lima Ferreira, F.C.; Nascimento Souza, D. do

    2008-01-01

    A quality control program to nuclear medicine services concerns the verification of the efficiency of equipment used to diagnosis and treatment, allow the professional improvement. In this study were assessed the performance of two radionuclide calibrators (activimeters) and of two scintigraphic cameras employed in nuclear medicine in the state of Sergipe, Brazil, according to regulation CNEN -NN-3.05. Additionally, to the radionuclide calibrators it was established a nd characterized an intercomparison of activities measured by different practitioners from standard samples of sealed radioactive sources of 133 Ba and 57 Co. The evaluation of this manufacture object was made thought quality control tests on scintigraphic cameras, such as: test of spatial resolution, tomographic resolution and linearity. The results of the quality control tests were satisfactory and they one can be used as parameter in future evaluations. (author)

  13. Multimodal quantitative phase and fluorescence imaging of cell apoptosis

    Science.gov (United States)

    Fu, Xinye; Zuo, Chao; Yan, Hao

    2017-06-01

    Fluorescence microscopy, utilizing fluorescence labeling, has the capability to observe intercellular changes which transmitted and reflected light microscopy techniques cannot resolve. However, the parts without fluorescence labeling are not imaged. Hence, the processes simultaneously happen in these parts cannot be revealed. Meanwhile, fluorescence imaging is 2D imaging where information in the depth is missing. Therefore the information in labeling parts is also not complete. On the other hand, quantitative phase imaging is capable to image cells in 3D in real time through phase calculation. However, its resolution is limited by the optical diffraction and cannot observe intercellular changes below 200 nanometers. In this work, fluorescence imaging and quantitative phase imaging are combined to build a multimodal imaging system. Such system has the capability to simultaneously observe the detailed intercellular phenomenon and 3D cell morphology. In this study the proposed multimodal imaging system is used to observe the cell behavior in the cell apoptosis. The aim is to highlight the limitations of fluorescence microscopy and to point out the advantages of multimodal quantitative phase and fluorescence imaging. The proposed multimodal quantitative phase imaging could be further applied in cell related biomedical research, such as tumor.

  14. Scintigraphic investigation of sacroiliac disease

    International Nuclear Information System (INIS)

    Lentle, B.C.; Russell, A.S.; Percy, J.S.; Jackson, F.I.

    1977-01-01

    Bone scintigraphs obtained with both technetium-99m polyphosphate and technetium-99m pyrophosphate have been abnormal at the sacroiliac joints of 44 patients with definite ankylosing spondylitis (AS). Because of the normal registration of the sacroiliac joints on bone scintigraphy, it has been necessary to develop a profile-scan technique to quantify the abnormality that proves to be significantly different from the normal finding. In 17 patients with a strong clinical suspicion of AS but normal radiographs, the sacroiliac joints have frequently been abnormal. This finding is meaningful because there is a common occurrence in this group of the histocompatibility antigen HL A-B27, known to be a marker of AS. We also note the frequency of abnormal sacroiliac scintigrams in 26 patients with rheumatoid arthritis and in a group of other diseases--Crohn's disease, uveitis, psoriasis, ulcerative colitis, and Reiters' disease--all of which share some of the manifestations of AS

  15. Hyper-functioning Thyroid Nodule with Scintigraphic Owl's Eye Appearance

    International Nuclear Information System (INIS)

    Al-Kordi, R.S.; Elgazzar, A.H.

    2006-01-01

    Hyper-functioning thyroid nodules may produce various scintigraphic appearances on thyroid scans. Autonomously hyper functioning thyroid nodules invariably demonstrate degenerative changes. These changes may give rise to central or less commonly peripheral photopenic areas on a thyroid scan within otherwise a hot nodule. In this report we present a case of hyper functioning autonomous nodule with peripheral degeneration and residual central functioning tissue giving the appearance of an owl's eye. Although rare, this pattern can be seen in a variety of benign and malignant thyroid conditions. (author)

  16. Contribution of different scintigraphic techniques to the management of medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Sandrock, D.; Blossey, H.C.; Steinroeder, M.; Munz, D.L.

    1989-01-01

    We compared three different scintigraphic techniques for the localization of neck recurrences and metastases in seven patients with medullary thyroid carcinoma one month to eight years after the first surgical intervention. Three successive scintigraphic studies were performed in five patients (6 x 3 studies) within two weeks using 201Tl chloride, 111In-labeled F(ab')2 fragments of the anti-carcinoembryonic antigen (anti-CEA) monoclonal antibody (MoAb) BW 431/31, and 131I meta-iodo-benzylguanidine (MIBG). Additionally, 11 studies were performed with the 111In-labeled MoAb fragment BW 431/31 (seven studies) or the 99mTc-labeled intact anti-CEA MoAb BW 431/26 (four studies). The gold standards for classifying scintigraphic results were biopsy, histology, surgery, and cytology. Six regions were classified as positive or negative in each study: thyroid region, four quadrants (lymph node regions) around the thyroid, and the region of the upper mediastinum. Of 36 sites, 201Tl was true positive (TP) in seven sites, false-positive (FP) in one site, true negative (TN) in 22 sites, and false-negative (FN) in six sites, resulting in a sensitivity of 54% and a specificity of 96%. 131I MIBG was TP in four sites, FP in none of the sites, TN in 23 sites, and FN in nine sites, with a sensitivity of 31% and a specificity of 100%. Immunoscintigraphy (102 sites overall) was TP in 16 sites, FP in five sites, TN in 77 sites, and FN in four sites, resulting in a sensitivity of 80% and a specificity of 94%. Immunoscintigraphy with 111In/99mTc anti-CEA F(ab')2 fragment/intact antibody is superior to scintigraphy with 201Tl and 131I MIBG

  17. Detection of cardiac wall motion defects with combined amplitude/phase analysis

    International Nuclear Information System (INIS)

    Bacharach, S.L.; Green, M.V.; Bonow, R.O.; Pace, L.; Brunetti, A.; Larson, S.M.

    1985-01-01

    Fourier phase images have been used with some success to detect and quantify left ventricular (LV) wall motion defects. In abnormal regions of the LV, wall motion asynchronies often cause the time activity curve (TAC) to be shifted in phase. Such regional shifts are detected by analysis of the distribution function of phase values over the LV. However, not all wall motion defects result in detectable regional phase abnormalities. Such abnormalities may cause a reduction in the magnitude of contraction (and hence TAC amplitude) without any appreciable change in TAC shape(and hence phase). In an attempt to improve the sensitivity of the Fourier phase method for the detection of wall motion defects the authors analyzed the distribution function of Fourier amplitude as well as phase. 26 individuals with normal cardiac function and no history of cardiac disease served as controls. The goal was to detect and quantify wall motion as compared to the consensus of 3 independent observers viewing the scintigraphic cines. 26 subjects with coronary artery disease and mild wall motion defects (22 with normal EF) were studied ate rest. They found that analysis of the skew of thew amplitude distribution function improved the sensitivity for the detection of wall motion abnormalities at rest in the group from 65% to 85% (17/26 detected by phase alone, 22/26 by combined phase and amplitude analysis) while retaining a 0 false positive rate in the normal group. The authors conclude that analysis of Fourier amplitude distribution functions can significantly increase the sensitivity of phase imaging for detection of wall motion abnormalities

  18. Imaging of Phase Objects using Partially Coherent Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Ravizza, F. L. [Univ. of Arizona, Tucson, AZ (United States)

    2013-01-01

    Screening high-power laser optics for light intensifying phase objects that cause laserinduced damage on downstream optics is critical to sustaining laser operation. Identifying such flaws on large-apertures is quite challenging since they are relatively small and invisible to conventional inspection methods. A Linescan Phase Differential Imaging (LPDI) system was developed to rapidly identify these flaws on large-aperture optics within a single full-aperture dark-field image. We describe a two-step production phase object screening process consisting of LPDI mapping and image analysis, followed by high-resolution interferometry and propagation based evaluation of the downstream damage potential of identified flaws. An image simulation code capable of modeling the LPDI partially coherent illumination was used to optimize its phase object sensitivity.

  19. Scintigraphic colonic transit study in children with chronic constipation

    International Nuclear Information System (INIS)

    Yano, Tsunehiro; Uemura, Sadashige; Nakaoka, Tatsuo; Nakagawa, Yoshikiyo; Tanimoto, Terutaka; Sone, Teruki

    2008-01-01

    Chronic constipation can be caused either by slow colonic transit or by functional fecal retention. The treatment strategy for chronic constipation should be based on its etiology. Scintigraphic colonic transit study (SCTS) is useful for dividing the cause of the constipation into slow colonic transit and functional fecal retention. SCTS is also useful for judging the therapeutic effect and postoperative intestinal motility of Hirschsprung's disease, anorectal molformation, and others. As SCTS is a safe, simple, and painless examination, it is one of the most important examinations in evaluating chronic constipation. (author)

  20. Phase-preserving beam expander for biomedical X-ray imaging

    International Nuclear Information System (INIS)

    Martinson, Mercedes; Samadi, Nazanin; Bassey, Bassey; Gomez, Ariel; Chapman, Dean

    2015-01-01

    Building on previous work, a phase-preserving bent Laue beam-expanding monochromator was developed with the capability of performing live animal phase contrast dynamic imaging at the Biomedical Imaging and Therapy beamline at the Canadian Light Source. The BioMedical Imaging and Therapy beamlines at the Canadian Light Source are used by many researchers to capture phase-based imaging data. These experiments have so far been limited by the small vertical beam size, requiring vertical scanning of biological samples in order to image their full vertical extent. Previous work has been carried out to develop a bent Laue beam-expanding monochromator for use at these beamlines. However, the first attempts exhibited significant distortion in the diffraction plane, increasing the beam divergence and eliminating the usefulness of the monochromator for phase-related imaging techniques. Recent work has been carried out to more carefully match the polychromatic and geometric focal lengths in a so-called ‘magic condition’ that preserves the divergence of the beam and enables full-field phase-based imaging techniques. The new experimental parameters, namely asymmetry and Bragg angles, were evaluated by analysing knife-edge and in-line phase images to determine the effect on beam divergence in both vertical and horizontal directions, using the flat Bragg double-crystal monochromator at the beamline as a baseline. The results show that by using the magic condition, the difference between the two monochromator types is less than 10% in the diffraction plane. Phase fringes visible in test images of a biological sample demonstrate that this difference is small enough to enable in-line phase imaging, despite operating at a sub-optimal energy for the wafer and asymmetry angle that was used

  1. Extracting flat-field images from scene-based image sequences using phase correlation

    Energy Technology Data Exchange (ETDEWEB)

    Caron, James N., E-mail: Caron@RSImd.com [Research Support Instruments, 4325-B Forbes Boulevard, Lanham, Maryland 20706 (United States); Montes, Marcos J. [Naval Research Laboratory, Code 7231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States); Obermark, Jerome L. [Naval Research Laboratory, Code 8231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States)

    2016-06-15

    Flat-field image processing is an essential step in producing high-quality and radiometrically calibrated images. Flat-fielding corrects for variations in the gain of focal plane array electronics and unequal illumination from the system optics. Typically, a flat-field image is captured by imaging a radiometrically uniform surface. The flat-field image is normalized and removed from the images. There are circumstances, such as with remote sensing, where a flat-field image cannot be acquired in this manner. For these cases, we developed a phase-correlation method that allows the extraction of an effective flat-field image from a sequence of scene-based displaced images. The method uses sub-pixel phase correlation image registration to align the sequence to estimate the static scene. The scene is removed from sequence producing a sequence of misaligned flat-field images. An average flat-field image is derived from the realigned flat-field sequence.

  2. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    International Nuclear Information System (INIS)

    Rubello, D.; Caricasulo, D.; Borsato, N.; Chierichetti, F.; Zanco, P.; Ferlin, G.

    1996-01-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic 99m TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  3. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, D. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Caricasulo, D. [Orthopaedics Dept., General Hospital of Bassano del Grappa (Italy); Borsato, N. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Chierichetti, F. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Zanco, P. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Ferlin, G. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy)

    1996-10-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic {sup 99m}TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  4. Magnetic Imaging with a Novel Hole-Free Phase Plate

    DEFF Research Database (Denmark)

    Pollard, Shawn; Malac, Marek; Beleggia, Marco

    2014-01-01

    One of the main interests in phase plate imaging is motivated by a decrease in irradiation dose needed to obtain desired signal to noise ratio, a result of improved contrast transfer [1]. The decrease in irradiation improves the imaging of biological materials [2]. Here we demonstrate that phase...... most phase objects, including magnetic and electrostatic fields in vacuum. The requirement for phase plate imaging, including that by HFPP, is that the object spectrum in the back focal plane of the objective lens must not be broadened via the effect of chromatic aberration. In other words, the imaged...

  5. Quantitative Phase Imaging Using Hard X Rays

    International Nuclear Information System (INIS)

    Nugent, K.A.; Gureyev, T.E.; Cookson, D.J.; Paganin, D.; Barnea, Z.

    1996-01-01

    The quantitative imaging of a phase object using 16keV xrays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. We find that our phase image is in quantitative agreement with independent measurements of the object. copyright 1996 The American Physical Society

  6. [Magnetic resonance imaging of tibial periostitis].

    Science.gov (United States)

    Meyer, X; Boscagli, G; Tavernier, T; Aczel, F; Weber, F; Legros, R; Charlopain, P; Martin, J P

    1998-01-01

    Tibial periostitis frequently occurs in athletes. We present our experience with MRI in a series of 7 patients (11 legs) with this condition. The clinical presentation and scintigraphic scanning suggested the diagnosis. MRI exploration of 11 legs demonstrated a high band-like juxta-osseous signal enhancement of SE and IR T2 weighted sequences in 6 cases, a signal enhancement after i.v. contrast administration in 4. Tibial periostitis is a clinical diagnosis and MRI and scintigraphic findings can be used to assure the differential diagnosis in difficult cases with stress fracture. MRI can visualize juxta-osseous edematous and inflammatory reactions and an increased signal would appear to be characteristic when the band-like image is fixed to the periosteum.

  7. The use of fast digital filters for the processing of scintigraphic pictures

    International Nuclear Information System (INIS)

    Grochulski, W.; Penczek, P.

    1982-01-01

    A brief review of typical methods applied in the development of digital filters for the processing of scintigraphic pictures is given. A simple parametrisation of such filters in the frequency domain is proposed and successfully applied in the case of mathematically simulated IAEA phantoms. The FFT algorithm is used. A possible application of the fast Walsh transform is pointed out. (author)

  8. Phase contrast image segmentation using a Laue analyser crystal

    International Nuclear Information System (INIS)

    Kitchen, Marcus J; Paganin, David M; Lewis, Robert A; Pavlov, Konstantin M; Uesugi, Kentaro; Allison, Beth J; Hooper, Stuart B

    2011-01-01

    Dual-energy x-ray imaging is a powerful tool enabling two-component samples to be separated into their constituent objects from two-dimensional images. Phase contrast x-ray imaging can render the boundaries between media of differing refractive indices visible, despite them having similar attenuation properties; this is important for imaging biological soft tissues. We have used a Laue analyser crystal and a monochromatic x-ray source to combine the benefits of both techniques. The Laue analyser creates two distinct phase contrast images that can be simultaneously acquired on a high-resolution detector. These images can be combined to separate the effects of x-ray phase, absorption and scattering and, using the known complex refractive indices of the sample, to quantitatively segment its component materials. We have successfully validated this phase contrast image segmentation (PCIS) using a two-component phantom, containing an iodinated contrast agent, and have also separated the lungs and ribcage in images of a mouse thorax. Simultaneous image acquisition has enabled us to perform functional segmentation of the mouse thorax throughout the respiratory cycle during mechanical ventilation.

  9. Phase-contrast X-ray imaging using an X-ray interferometer for biological imaging

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi; Koyama, Ichiro [Tokyo Univ., Dept. of Applied Physics, Tokyo (Japan); Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Inst. of Clinical Medicine, Tsukuba, Ibaraki (Japan); Yoneyama, Akio [Hitachi Ltd., Advanced Research Laboratory, Saitama (Japan)

    2002-04-01

    The potential of phase-contrast X-ray imaging using an X-ray interferometer is discussed comparing with other phase-contrast X-ray imaging methods, and its principle of contrast generation is presented including the case of phase-contrast X-ray computed tomography. The status of current instrumentation is described and perspectives for practical applications are discussed. (author)

  10. Correlation between radiological, scintigraphic and histological changes in bone in rabbits following irradiation with single and fractionated doses

    International Nuclear Information System (INIS)

    Burgener, F.A.; King, M.A.; Weber, D.A.

    1979-01-01

    In the left hind legs of eight rabbits were irradiated with 1,750 rad in a single dose or with 4,650 rad divided over a period of three weeks. These animals, as well as four who had not been irradiated, were examined periodically radiologically and with 99 mTechnetium pyrophosphate scintigrams during one year. No difference could be detected between the results of the single and fractionated doses. Scintigraphically there was a biphasic increase in uptake, the first peak co-inciding with the irradiation and of vascular origin, whereas the second peak occured at four months and was due to a change in bone metabolism. At the end of a year uptake in the irradiated limb was slightly reduced. The earliest radiological changes were found after six months, at the end of the second scintigraphic peak; they consisted of coarsening and blurring of the trabeculae, non-homogeneous spotty mineralisation and endosteal scalloping. Six animals developed a radiation-induced bone sarcoma, first demonstrated either by scintigraphy or radiology depending on its histology. The value of combining radiological and scintigraphic examinations for the early detection of post-radiation abnormalities is stressed. (orig.) [de

  11. Scintigraphic determination of gastrointestinal transit times. A comparison with breath hydrogen and radiologic methods

    DEFF Research Database (Denmark)

    Madsen, J L; Larsen, N E; Hilsted, J

    1991-01-01

    A scintigraphic method for determination of gastrointestinal transit times was compared with the breath hydrogen test and a multiple-bolus, single-radiograph technique. A close temporal association was found between the caecal appearance of radioactivity and the onset of breath hydrogen excretion...... the breath hydrogen concentration profiles....

  12. Troubleshooting arterial-phase MR images of gadoxetate disodium-enhanced liver

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Ji Mi; Kim, So Yeon; Lee, Seung Soo; Kim, Kyoung Won [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yeh, Benjamin M.; Wang, Z. Jane [Dept. of Radiologyand Biomedical Imaging, University of California San Francisco, San Francisco (United States); Wu, En Haw [Dept. of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou and Chang Gung University College of Medicine, Taoyuan (China); Zhao, Li Qin [Beijing Friendship Hospital, Capital Medical University, Beijing (China); Chang, Wei Chou [Tri-Service General Hospital and National Defense Medical Center, Taipei (China)

    2015-12-15

    Gadoxetate disodium is a widely used magnetic resonance (MR) contrast agent for liver MR imaging, and it provides both dynamic and hepatobiliary phase images. However, acquiring optimal arterial phase images at liver MR using gadoxetate disodium is more challenging than using conventional extracellular MR contrast agent because of the small volume administered, the gadolinium content of the agent, and the common occurrence of transient severe motion. In this article, we identify the challenges in obtaining high-quality arterial-phase images of gadoxetate disodium-enhanced liver MR imaging and present strategies for optimizing arterial-phase imaging based on the thorough review of recent research in this field.

  13. Troubleshooting arterial-phase MR images of gadoxetate disodium-enhanced liver

    International Nuclear Information System (INIS)

    Huh, Ji Mi; Kim, So Yeon; Lee, Seung Soo; Kim, Kyoung Won; Yeh, Benjamin M.; Wang, Z. Jane; Wu, En Haw; Zhao, Li Qin; Chang, Wei Chou

    2015-01-01

    Gadoxetate disodium is a widely used magnetic resonance (MR) contrast agent for liver MR imaging, and it provides both dynamic and hepatobiliary phase images. However, acquiring optimal arterial phase images at liver MR using gadoxetate disodium is more challenging than using conventional extracellular MR contrast agent because of the small volume administered, the gadolinium content of the agent, and the common occurrence of transient severe motion. In this article, we identify the challenges in obtaining high-quality arterial-phase images of gadoxetate disodium-enhanced liver MR imaging and present strategies for optimizing arterial-phase imaging based on the thorough review of recent research in this field

  14. Scintigraphic diagnosis of stress-induced incomplete fractures of the proximal tibia

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Akhtar, K.; Isitman, A.T.

    1984-01-01

    Incomplete stress fractures of the proximal tibial diaphysis can be diagnosed by bone scintigraphy. The scintigraphic appearance of incomplete rather than complete tibial stress fractures is apparently reported for the first time in this article. With no treatment other than restricted activity, this injury heals rapidly and completely in 4 to 6 weeks. The major threat to the patient's welfare is unfounded suspicion of tumor or infection which may lead to biopsy or inappropriate therapy

  15. Assessment of skeleton scintigraphic study in breast cancer patients (relative to 322 observations)

    International Nuclear Information System (INIS)

    Liechtmaneger, Nicole.

    1976-01-01

    The results of scintigraphic whole-skeleton examinations have recently been improved by the use of sup(99m)Tc labelled phosphorus compounds. An assessment was made of 368 explorations, most of which were carried out with pyrophosphates and a few, the most recent, with ethane hydroxy diphosphonate, both labelled with sup(99m)Tc. For pyrophosphates a 10 mCi intraveinous injection is followed by a latency time of about 3 hours before the scintigraphic examination. In the case of diphosphonates, which have only been used lately and on relatively few cases, the same 10 mCi intravenous injection is administered but the latency time before the examination is only half as long, i.e. about 1h30 min, which is a definite advantage. However the number of examinations carried out with the latter is too small to afford a significant comparison between the two products. The main object of this work is to count the hyperfixation centres and to estimate their specificity and their coexistence or otherwise with clinical or radiological signs [fr

  16. Screening for skeletal metastases of the spine and pelvis: gradient echo opposed-phase MRI compared with bone scintigraphy

    International Nuclear Information System (INIS)

    Neumann, K.; Hosten, N.; Venz, S.

    1995-01-01

    Opposed-phase gradient echo (GRE) MRI at 0.5 T was compared with T1-weighted GRE MRI and bone scintigraphy regarding the detection of malignant bone marrow infiltrates of the spine and pelvis. Seventeen control patients and 41 patients with suspected skeletal metastases were studied with plain and gadolinium-enhanced MRI. In the control group only a vertebral haemangioma showed contrast enhancement, while all metastases (confirmed histologically or by follow-up) were enhancing. Opposed-phase surface coil MRI showed a significantly higher contrast-to-noise ratio of 56 metastases than T1-weighted images. In 28 patients body coil opposed-phase MRI detected more metastatic foci of the spine and pelvis than did bone scintigraphy (84 vs 56). No scintigraphically visualised lesion was missed by MRI. In conclusion, body coil gadolinium-enhanced opposed-phase GRE MRI may be applied as a screening method for skeletal metastases of the spine and pelvis at intermediate field strengths. (orig.)

  17. Screening for skeletal metastases of the spine and pelvis: gradient echo opposed-phase MRI compared with bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, K. [Zentralinstitut fuer Roentgendiagnostik, Universitaetsklinikum Essen, Gesamthochschule Essen (Germany); Hosten, N. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Venz, S. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1995-11-01

    Opposed-phase gradient echo (GRE) MRI at 0.5 T was compared with T1-weighted GRE MRI and bone scintigraphy regarding the detection of malignant bone marrow infiltrates of the spine and pelvis. Seventeen control patients and 41 patients with suspected skeletal metastases were studied with plain and gadolinium-enhanced MRI. In the control group only a vertebral haemangioma showed contrast enhancement, while all metastases (confirmed histologically or by follow-up) were enhancing. Opposed-phase surface coil MRI showed a significantly higher contrast-to-noise ratio of 56 metastases than T1-weighted images. In 28 patients body coil opposed-phase MRI detected more metastatic foci of the spine and pelvis than did bone scintigraphy (84 vs 56). No scintigraphically visualised lesion was missed by MRI. In conclusion, body coil gadolinium-enhanced opposed-phase GRE MRI may be applied as a screening method for skeletal metastases of the spine and pelvis at intermediate field strengths. (orig.)

  18. Differential diagnosis of scintigraphic brain centres by 75Se selenite

    International Nuclear Information System (INIS)

    Bestagno, M.; Garraffa, V.; Rembado, R.; Guerra, U.

    1975-01-01

    Since standard brain scintigraphy with sup(99m)Tc is not always adequate for a satisfactory differential diagnosis of the radioactive foci detected, the possibilities of 75 Se sodium selenite were investigated. It was observed that in centres due to a vascular lesion the selenite concentration is always low, rising steeply in neoplasmic foci. The 75 Se-selenite scintigraphic method is considered highly valid, complementing that of sup(99m)Tc when this latter is unsuitable for diagnosis of the nature of cerebral foci [fr

  19. Tomographic image reconstruction using x-ray phase information

    Science.gov (United States)

    Momose, Atsushi; Takeda, Tohoru; Itai, Yuji; Hirano, Keiichi

    1996-04-01

    We have been developing phase-contrast x-ray computed tomography (CT) to make possible the observation of biological soft tissues without contrast enhancement. Phase-contrast x-ray CT requires for its input data the x-ray phase-shift distributions or phase-mapping images caused by an object. These were measured with newly developed fringe-scanning x-ray interferometry. Phase-mapping images at different projection directions were obtained by rotating the object in an x-ray interferometer, and were processed with a standard CT algorithm. A phase-contrast x-ray CT image of a nonstained cancerous tissue was obtained using 17.7 keV synchrotron x rays with 12 micrometer voxel size, although the size of the observation area was at most 5 mm. The cancerous lesions were readily distinguishable from normal tissues. Moreover, fine structures corresponding to cancerous degeneration and fibrous tissues were clearly depicted. It is estimated that the present system is sensitive down to a density deviation of 4 mg/cm3.

  20. Phase-contrast tomographic imaging using an X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Momose, A. [Hitachi Ltd, Advanced Research Lab., Saitama (Japan); Takeda, T.; Itai, Y. [Univ. of Tsukuba, Inst. of Clinical Medicine, Ibaraki (Japan); Yoneyama, A. [Hitachi Ltd, Central Resarch Lab., Tokyo (Japan); Hirano, K. [High Energy Accelerator Research Organization, Inst. of Materials Structure Science, Ibaraki (Japan)

    1998-05-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays. 35 refs.

  1. Phase-contrast tomographic imaging using an X-ray interferometer

    International Nuclear Information System (INIS)

    Momose, A.; Takeda, T.; Itai, Y.; Yoneyama, A.; Hirano, K.

    1998-01-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays

  2. Fourier domain image fusion for differential X-ray phase-contrast breast imaging

    International Nuclear Information System (INIS)

    Coello, Eduardo; Sperl, Jonathan I.; Bequé, Dirk; Benz, Tobias; Scherer, Kai; Herzen, Julia; Sztrókay-Gaul, Anikó; Hellerhoff, Karin; Pfeiffer, Franz; Cozzini, Cristina; Grandl, Susanne

    2017-01-01

    X-Ray Phase-Contrast (XPC) imaging is a novel technology with a great potential for applications in clinical practice, with breast imaging being of special interest. This work introduces an intuitive methodology to combine and visualize relevant diagnostic features, present in the X-ray attenuation, phase shift and scattering information retrieved in XPC imaging, using a Fourier domain fusion algorithm. The method allows to present complementary information from the three acquired signals in one single image, minimizing the noise component and maintaining visual similarity to a conventional X-ray image, but with noticeable enhancement in diagnostic features, details and resolution. Radiologists experienced in mammography applied the image fusion method to XPC measurements of mastectomy samples and evaluated the feature content of each input and the fused image. This assessment validated that the combination of all the relevant diagnostic features, contained in the XPC images, was present in the fused image as well.

  3. Fourier domain image fusion for differential X-ray phase-contrast breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Coello, Eduardo, E-mail: eduardo.coello@tum.de [GE Global Research, Garching (Germany); Lehrstuhl für Informatikanwendungen in der Medizin & Augmented Reality, Institut für Informatik, Technische Universität München, Garching (Germany); Sperl, Jonathan I.; Bequé, Dirk [GE Global Research, Garching (Germany); Benz, Tobias [Lehrstuhl für Informatikanwendungen in der Medizin & Augmented Reality, Institut für Informatik, Technische Universität München, Garching (Germany); Scherer, Kai; Herzen, Julia [Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, Garching (Germany); Sztrókay-Gaul, Anikó; Hellerhoff, Karin [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich (Germany); Pfeiffer, Franz [Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, Garching (Germany); Cozzini, Cristina [GE Global Research, Garching (Germany); Grandl, Susanne [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich (Germany)

    2017-04-15

    X-Ray Phase-Contrast (XPC) imaging is a novel technology with a great potential for applications in clinical practice, with breast imaging being of special interest. This work introduces an intuitive methodology to combine and visualize relevant diagnostic features, present in the X-ray attenuation, phase shift and scattering information retrieved in XPC imaging, using a Fourier domain fusion algorithm. The method allows to present complementary information from the three acquired signals in one single image, minimizing the noise component and maintaining visual similarity to a conventional X-ray image, but with noticeable enhancement in diagnostic features, details and resolution. Radiologists experienced in mammography applied the image fusion method to XPC measurements of mastectomy samples and evaluated the feature content of each input and the fused image. This assessment validated that the combination of all the relevant diagnostic features, contained in the XPC images, was present in the fused image as well.

  4. Comparing imaging procedures: techniques and examples. Gastroenterology

    International Nuclear Information System (INIS)

    Malmud, L.S.

    1982-01-01

    The distinct advantages of nuclear medicine procedures, in comparison to radiography, contrast studies, computerized tomography and ultrasound, are emphasized. Scintigraphic methods offer quantitative data regarding function which competing imaging modalities are unable to provide, and make them the studies of choice in the evaluation of gastrointestinal physiology and functional abnormalities

  5. The scintigraphic investigation of sacroiliac disease.

    Science.gov (United States)

    Lentle, B C; Russell, A S; Percy, J S; Jackson, F I

    1977-06-01

    Bone scintigraphs obtained with both Technetium-99m polyphosphate and Technetium-99m pyrophosphate have been abnormal at the sacroiliac joints of 44 patients with definite ankylosing spondylitis (AS). Because of the normal registration of the sacroiliac joints on bone scintigraphy, it has been necessary to develop a profile-scan technique to quantify the abnormality that proves to be significantly different from the normal finding. In 17 patients with a strong clinical suspicion of AS but normal radiographs, the sacroiliac joints have frequently been abnormal. This finding is meaningful because there is a common occurence in this group of the histocompatibility antigen HL A-B27, known to be a marker of AS. We also note the frequency of abnormal sacroiliac scinitigrams in 26 patients with rheumatoid arthritis and in a group of other diseases-Crohn's disease, uveitis, psoriasis, ulcerative colitis, and Reiter's disease-all of which share some of the manifestations of AS.

  6. Multichannel far-infrared phase imaging for fusion plasmas

    International Nuclear Information System (INIS)

    Young, P.E.; Neikirk, D.P.; Tong, P.P.; Rutledge, D.B.; Luhmann, N.C. Jr.

    1985-01-01

    A 20-channel far-infrared imaging interferometer system has been used to obtain single-shot density profiles in the UCLA Microtor tokamak. This system differs from conventional multichannel interferometers in that the phase distribution produced by the plasma is imaged onto a single, monolithic, integrated microbolometer linear detector array and provides significantly more channels than previous far-infrared interferometers. The system has been demonstrated to provide diffraction-limited phase images of dielectric targets

  7. Scintigraphic scoring system for grading severity of gastro-esophageal reflux on 99mTc sulfur colloid gastro-esophageal reflux scintigraphy: A prospective study of 39 cases with pre and post treatment assessment.

    Science.gov (United States)

    Puranik, Ameya D; Nair, Gopinathan; Aggarwal, Rajiv; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand

    2013-04-01

    The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99mTc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value reflux and also for following children post-treatment.

  8. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  9. Imaging of acute myocardial infarction in pigs with Indium-111 monoclonal antimyosin scintigraphy and MRI

    International Nuclear Information System (INIS)

    Kate, C.I.; Kroonenburgh, M.J. van; Schipperheyn, J.J.; Doornbos, J.; Hoedemaeker, P.J.; Maes, A.; Nat, K.H. van der; Camps, J.A.; Huysmans, H.A.; Pauwels, E.K.

    1990-01-01

    Indium-111 antimyosin F(ab')2 was used in a series of scintigraphic studies on experimentally induced myocardial infarctions in pigs. Antimyosin distribution recorded by planar images of in vivo pigs and by single photon emission computed tomography (SPECT) of excised hearts delineated areas of myocardial necrosis if infarct volume exceeded 3.3 cm3. Scintigraphic images were compared with magnetic resonance images (MRI) obtained from excised hearts and with photographs of slices of the hearts. Infarct size and localization determined with antimyosin were compared. The MR images, with or without gadolinium-DTPA (Gd-DTPA), of the in vivo pigs were all false-negative; some myocardial wall thinning and high bloodpool signals were visible. Results show that both the antimyosin and the MR technique are specific methods for the visualization of induced myocardial necrosis in this animal model. However, the use of antimyosin is limited to a period ranging from 24 to 72 hours after infarction

  10. Study of key technology of ghost imaging via compressive sensing for a phase object based on phase-shifting digital holography

    International Nuclear Information System (INIS)

    Leihong, Zhang; Dong, Liang; Bei, Li; Zilan, Pan; Dawei, Zhang; Xiuhua, Ma

    2015-01-01

    In this article, the algorithm of compressing sensing is used to improve the imaging resolution and realize ghost imaging via compressive sensing for a phase object based on the theoretical analysis of the lensless Fourier imaging of the algorithm of ghost imaging based on phase-shifting digital holography. The algorithm of ghost imaging via compressive sensing based on phase-shifting digital holography uses the bucket detector to measure the total light intensity of the interference and the four-step phase-shifting method is used to obtain the total light intensity of differential interference light. The experimental platform is built based on the software simulation, and the experimental results show that the algorithm of ghost imaging via compressive sensing based on phase-shifting digital holography can obtain the high-resolution phase distribution figure of the phase object. With the same sampling times, the phase clarity of the phase distribution figure obtained by the algorithm of ghost imaging via compressive sensing based on phase-shifting digital holography is higher than that obtained by the algorithm of ghost imaging based on phase-shift digital holography. In this article, this study further extends the application range of ghost imaging and obtains the phase distribution of the phase object. (letter)

  11. Quantification of signal detection performance degradation induced by phase-retrieval in propagation-based x-ray phase-contrast imaging

    Science.gov (United States)

    Chou, Cheng-Ying; Anastasio, Mark A.

    2016-04-01

    In propagation-based X-ray phase-contrast (PB XPC) imaging, the measured image contains a mixture of absorption- and phase-contrast. To obtain separate images of the projected absorption and phase (i.e., refractive) properties of a sample, phase retrieval methods can be employed. It has been suggested that phase-retrieval can always improve image quality in PB XPC imaging. However, when objective (task-based) measures of image quality are employed, this is not necessarily true and phase retrieval can be detrimental. In this work, signal detection theory is utilized to quantify the performance of a Hotelling observer (HO) for detecting a known signal in a known background. Two cases are considered. In the first case, the HO acts directly on the measured intensity data. In the second case, the HO acts on either the retrieved phase or absorption image. We demonstrate that the performance of the HO is superior when acting on the measured intensity data. The loss of task-specific information induced by phase-retrieval is quantified by computing the efficiency of the HO as the ratio of the test statistic signal-to-noise ratio (SNR) for the two cases. The effect of the system geometry on this efficiency is systematically investigated. Our findings confirm that phase-retrieval can impair signal detection performance in XPC imaging.

  12. Single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin combined with SPECT technique in patients with secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Botushanova, A.; Yaneva, M.; Botushanov, N.

    2015-01-01

    Full text: Preoperative parathyroid scintigraphy is highly beneficial when used for minimally invasive parathyroidectomy. The aim is to examine the diagnostic value of single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-etrofosmin combined with SPECT technique in preoperative localization of hyperplastic parathyroid glands in patients with secondary hyperparathyroidism. The study included 15 patients aged 37 to 73 years (8 women and 7 men) with proven secondary hyperparathyroidism with increased serum calcium and parathyroid hormone. All patients were on chroniodialysis and treatment with Calcitriol. The examination was done with two-headed SPECT gamma camera SIMBIA by protocol for single isotope dual-phase scintigraphy and SPECT technique. 740 MBq 99mTc-MIBI were applied intravenously in 6 of the patients, and in 9 patients were administered 740 MBq 99mTc-tetrofosmin. The scintigraphy with 99mTc-MIBI visualized a focus of residual activity in 4 patients, and in 2 we received negative scintigraphy. The scintigraphy with 99mTc-tetrofosmin combined with SPECT showed an area of hyperfixation in both phases on SPECT images in 1 patient. In 2 patients hyperfixating areas suspicious for abnormal parathyroid glands were registered only in the early SPECT images. In 6 patients the scintigraphic results were negative. Negative scintigraphic results can be explained with the ability to suppress the uptake of 99mTc-MIBI and 99mTc - tetrofosmin by the parathyroid cells as a result of taking Calcitriol. Scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin did not show high sensitivity in identifying the hyperplastic parathyroid glands, although it was capable to distinguish patients with nodular hyperplasia of those with diffuse hyperplasia

  13. Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility

    International Nuclear Information System (INIS)

    Xiong Zhuang; Wang Jianhua; Yu Yongqiang; Jiang Shiping; Chen Yang; Tian Yulian

    2006-01-01

    Objective: To study the methodology of X-ray phase contrast imaging using synchrotron radiation, and evaluate the quality of phase contrast images. Methods: Several experiments to obtain phase contrast images and absorption contrast images of various biological samples were conducted in Beijing Synchrotron Radiation Facility (BSRF), and then these images were interpreted to find out the difference between the two kinds of imaging methods. Results: Satisfactory phase contrast images of these various samples were obtained, and the quality of these images was superior to that obtained with absorption contrast imaging. The phase contrast formation is based on the phenomenon of fresnel diffraction which transforms phase shifts into intensity variations upon a simple act of free-space propagation, so it requires highly coherent X-rays and appropriate distance between sample and detector. This method of imaging is very useful in imaging of low-absorption objects or objects with little absorption variation, and its resolution is far higher than that of the conventional X-ray imaging. The photographs obtained showed very fine inner microstructure of the biological samples, and the smallest microstructure to be distinguished is within 30-40 μm. There is no doubt that phase contrast imaging has a practical applicability in medicine. Moreover, it improves greatly the efficiency and the resolution of the existing X-ray diagnostic techniques. Conclusions: X-ray phase contrast imaging can be performed with synchrotron radiation source and has some advantages over the conventional absorption contrast imaging. (authors)

  14. Scintigraphic assessment of ectopic splenic tissue localization and function following splenectomy for trauma

    Energy Technology Data Exchange (ETDEWEB)

    Zwas, S.T.; Samra, D.; Samra, Y.; Sibber, G.R.

    1986-07-01

    Twenty-three subjects who had a splenectomy as a result of trauma underwent scintigraphic evaluation with a sensitive heat-denatured sup(99m)Tc-labeled red blood cells (DRBC). This method enabled detection of ectopic splenic tissue foci (ESTF) as small as 1x1 cm in diameter. ESTF splenosis or accessory spleen was detected in 15 cases (65%), a higher incidence than previously reported. The size of the ESTF ranged from 1x1 to 5x10 cm (0.8-40 cm/sup 2/), and 53% were less than 2x2 cma (3 cm/sup 2/). A new multiparametric scintigraphic evaluating technique is described, which estimates the quantity of ESTF and its grade of activity, relative to that of the liver. The technique is a highly efficient assessor of ESTF function. Good correlation was found between the size and activity of the ESTF and the presence of Howell-Jolly bodies (HJB), but with a low sensitivity for detecting small ESTF. Correlation was low between residual splenic tissue and concentrations of IgM, IgA and IgG immunoglobulins. The sup(99m)Tc-DRBC method described is recommended for verification of ESTF existence, localization, and function.

  15. Scintigraphic assessment of ectopic splenic tissue localization and function following splenectomy for trauma

    International Nuclear Information System (INIS)

    Zwas, S.T.

    1986-01-01

    Twenty-three subjects who had a splenectomy as a result of trauma underwent scintigraphic evaluation with a sensitive heat-denatured sup(99m)Tc-labeled red blood cells (DRBC). This method enabled detection of ectopic splenic tissue foci (ESTF) as small as 1x1 cm in diameter. ESTF splenosis or accessory spleen was detected in 15 cases (65%), a higher incidence than previously reported. The size of the ESTF ranged from 1x1 to 5x10 cm (0.8-40 cm 2 ), and 53% were less than 2x2 cma (3 cm 2 ). A new multiparametric scintigraphic evaluating technique is described, which estimates the quantity of ESTF and its grade of activity, relative to that of the liver. The technique is a highly efficient assessor of ESTF function. Good correlation was found between the size and activity of the ESTF and the presence of Howell-Jolly bodies (HJB), but with a low sensitivity for detecting small ESTF. Correlation was low between residual splenic tissue and concentrations of IgM, IgA and IgG immunoglobulins. The sup(99m)Tc-DRBC method described is recommended for verification of ESTF existence, localization, and function. (orig.)

  16. Analyser-based phase contrast image reconstruction using geometrical optics

    International Nuclear Information System (INIS)

    Kitchen, M J; Pavlov, K M; Siu, K K W; Menk, R H; Tromba, G; Lewis, R A

    2007-01-01

    Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (<100 μm), whilst quantitative phase and attenuation information can be extracted using just two images when the approximations of geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser

  17. Space-Ready Advanced Imaging System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II effort Toyon will increase the state-of-the-art for video/image systems. This will include digital image compression algorithms as well as system...

  18. Scintigraphic measurements of the heart-blood-pool in dialyzed chronic uremic patients

    International Nuclear Information System (INIS)

    Nagy, E.S.; Nemessanyi, Z.; Narai, G.; Szegedi Orvostudomanyi Egyetem; Szegedi Orvostudomanyi Egyetem

    1976-01-01

    The authors have carried out scintigraphic measurements of the heart in order to diagnose the presence of an exudative pericarditis 50 times in 26 dialyzed uremic patients. Within the one year's observation 13 patients had an exudative pericarditis from the beginning on. In 8 cases a regression of the exudation could be observed. The examination has a low risk for the patient and is suitable to demonstrate clinically relevant pericardial liquid accumulation. (orig.) [de

  19. Two-Dimensional Image Fusion of Planar Bone Scintigraphy and Radiographs in Patients with Clinical Scaphoid Fracture: An Imaging Study

    DEFF Research Database (Denmark)

    Henriksen, O.M.; Lonsdale, M.N.; Jensen, T.D.

    2008-01-01

    . Bone scintigraphy is highly sensitive for the detection of fractures, but exact localization of scintigraphic lesions may be difficult and can negatively affect diagnostic accuracy. Purpose: To investigate the influence of image fusion of planar bone scintigraphy and radiographs on image interpretation......Background: Although magnetic resonance imaging (MRI) is now considered the gold standard in second-line imaging of patients with suspected scaphoid fracture and negative radiographs, bone scintigraphy can be used in patients with pacemakers, metallic implants, or other contraindications to MRI....... Conclusion: Image fusion of planar bone scintigrams and radiographs has a significant influence on image interpretation and increases both diagnostic confidence and interobserver agreement Udgivelsesdato: 2008/12/3...

  20. Two-dimensional fusion imaging of planar bone scintigraphy and radiographs in patients with clinical scaphoid fracture: an imaging study

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Lonsdale, Markus Georg; Jensen, T D

    2009-01-01

    . Bone scintigraphy is highly sensitive for the detection of fractures, but exact localization of scintigraphic lesions may be difficult and can negatively affect diagnostic accuracy. PURPOSE: To investigate the influence of image fusion of planar bone scintigraphy and radiographs on image interpretation......BACKGROUND: Although magnetic resonance imaging (MRI) is now considered the gold standard in second-line imaging of patients with suspected scaphoid fracture and negative radiographs, bone scintigraphy can be used in patients with pacemakers, metallic implants, or other contraindications to MRI....... CONCLUSION: Image fusion of planar bone scintigrams and radiographs has a significant influence on image interpretation and increases both diagnostic confidence and interobserver agreement....

  1. Nationwide standardisation and evaluation of scintigraphic gastric emptying: reference values and comparisons between subgroups in a multicentre trial

    International Nuclear Information System (INIS)

    Grybaeck, P.; Hermansson, G.; Lyrenaes, E.; Beckman, K.-W.; Jacobsson, H.; Hellstroem, P.M.

    2000-01-01

    By means of a standardised procedure, reference values for scintigraphic gastric emptying were established. The influence of gender, age, menstrual cycle, body mass index (BMI) and smoking habits was also evaluated. Eight centres recruited 20 healthy subjects each. The meal consisted of a technetium-99m labelled omelet (1300 kJ) and of 150 ml unlabelled soft drink. Geometric means of frontal and dorsal acquisitions were utilised in a linear fit model for determination of the linear emptying rate, and by using the intercepts of the regression line with the 90% and 50% levels, the lag phase and half-emptying time, respectively, were defined. All individuals showed an initial lag phase and subsequent linear emptying. Because of a longer lag phase and a slower linear emptying rate, premenopausal women had a slower gastric emptying than postmenopausal women and men of all ages. The gastric emptying rate increased with age in the women, mainly due to a shortened lag phase, while the emptying rate remained almost unchanged with age in the males. There were no significant differences in results between the centres. The menstrual cycle, BMI and smoking habits did not affect emptying. In conclusion, the fact that the results showed a slower gastric emptying rate in younger women compared with older women and men indicates that it is necessary to use separate reference values for fertile females. (orig.)

  2. Nationwide standardisation and evaluation of scintigraphic gastric emptying: reference values and comparisons between subgroups in a multicentre trial

    Energy Technology Data Exchange (ETDEWEB)

    Grybaeck, P. [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Hermansson, G. [Department of Clinical Physiology, Oestra Hospital, Goeteborg (Sweden); Lyrenaes, E. [Department of Medicine, Blekinge Hospital, Karlskrona (Sweden); Beckman, K.-W. [Hospital Physics, Oerebro Hospital (Sweden); Jacobsson, H. [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Department of Nuclear Medicine, Karolinska Hospital, Stockholm (Sweden); Hellstroem, P.M. [Department of Gastroenterology and Hepatology, Karolinska Hospital, Stockholm (Sweden)

    2000-06-01

    By means of a standardised procedure, reference values for scintigraphic gastric emptying were established. The influence of gender, age, menstrual cycle, body mass index (BMI) and smoking habits was also evaluated. Eight centres recruited 20 healthy subjects each. The meal consisted of a technetium-99m labelled omelet (1300 kJ) and of 150 ml unlabelled soft drink. Geometric means of frontal and dorsal acquisitions were utilised in a linear fit model for determination of the linear emptying rate, and by using the intercepts of the regression line with the 90% and 50% levels, the lag phase and half-emptying time, respectively, were defined. All individuals showed an initial lag phase and subsequent linear emptying. Because of a longer lag phase and a slower linear emptying rate, premenopausal women had a slower gastric emptying than postmenopausal women and men of all ages. The gastric emptying rate increased with age in the women, mainly due to a shortened lag phase, while the emptying rate remained almost unchanged with age in the males. There were no significant differences in results between the centres. The menstrual cycle, BMI and smoking habits did not affect emptying. In conclusion, the fact that the results showed a slower gastric emptying rate in younger women compared with older women and men indicates that it is necessary to use separate reference values for fertile females. (orig.)

  3. Imaging phase holdup distribution of three phase flow systems using dual source gamma ray tomography

    International Nuclear Information System (INIS)

    Varma, Rajneesh; Al-Dahhan, Muthanna; O'Sullivan, Joseph

    2008-01-01

    Full text: Multiphase reaction and process systems are used in abundance in the chemical and biochemical industry. Tomography has been successfully employed to visualize the hydrodynamics of multiphase systems. Most of the tomography methods (gamma ray, x-ray and electrical capacitance and resistance) have been successfully implemented for two phase dynamic systems. However, a significant number of chemical and biochemical systems consists of dynamic three phases. Research effort directed towards the development of tomography techniques to image such dynamic system has met with partial successes for specific systems with applicability to limited operating conditions. A dual source tomography scanner has been developed that uses the 661 keV and 1332 keV photo peaks from the 137 Cs and 60 Co for imaging three phase systems. A new approach has been developed and applied that uses the polyenergetic Alternating Minimization (A-M) algorithm, developed by O'Sullivan and Benac (2007), for imaging the holdup distribution in three phases' dynamic systems. The new approach avoids the traditional post image processing approach used to determine the holdup distribution where the attenuation images of the mixed flow obtained from gamma ray photons of two different energies are used to determine the holdup of three phases. In this approach the holdup images are directly reconstructed from the gamma ray transmission data. The dual source gamma ray tomography scanner and the algorithm were validated using a three phase phantom. Based in the validation, three phase holdup studies we carried out in slurry bubble column containing gas liquid and solid phases in a dynamic state using the dual energy gamma ray tomography. The key results of the holdup distribution studies in the slurry bubble column along with the validation of the dual source gamma ray tomography system would be presented and discussed

  4. Improving image quality of parallel phase-shifting digital holography

    International Nuclear Information System (INIS)

    Awatsuji, Yasuhiro; Tahara, Tatsuki; Kaneko, Atsushi; Koyama, Takamasa; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2008-01-01

    The authors propose parallel two-step phase-shifting digital holography to improve the image quality of parallel phase-shifting digital holography. The proposed technique can increase the effective number of pixels of hologram twice in comparison to the conventional parallel four-step technique. The increase of the number of pixels makes it possible to improve the image quality of the reconstructed image of the parallel phase-shifting digital holography. Numerical simulation and preliminary experiment of the proposed technique were conducted and the effectiveness of the technique was confirmed. The proposed technique is more practical than the conventional parallel phase-shifting digital holography, because the composition of the digital holographic system based on the proposed technique is simpler.

  5. Phase Image Analysis in Conduction Disturbance Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kwark, Byeng Su; Choi, Si Wan; Kang, Seung Sik; Park, Ki Nam; Lee, Kang Wook; Jeon, Eun Seok; Park, Chong Hun [Chung Nam University Hospital, Daejeon (Korea, Republic of)

    1994-03-15

    It is known that the normal His-Purkinje system provides for nearly synchronous activation of right (RV) and left (LV) ventricles. When His-Purkinje conduction is abnormal, the resulting sequence of ventricular contraction must be correspondingly abnormal. These abnormal mechanical consequences were difficult to demonstrate because of the complexity and the rapidity of its events. To determine the relationship of the phase changes and the abnormalities of ventricular conduction, we performed phase image analysis of Tc-RBC gated blood pool scintigrams in patients with intraventricular conduction disturbances (24 complete left bundle branch block (C-LBBB), 15 complete right bundle branch block (C-RBBB), 13 Wolff-Parkinson-White syndrome (WPW), 10 controls). The results were as follows; 1) The ejection fraction (EF), peak ejection rate (PER), and peak filling rate (PFR) of LV in gated blood pool scintigraphy (GBPS) were significantly lower in patients with C-LBBB than in controls (44.4 +- 13.9% vs 69.9 +- 4.2%, 2.48 +- 0.98 vs 3.51 +- 0,62, 1.76 +- 0.71 vs 3.38 +- 0.92, respectively, p<0.05). 2) In the phase angle analysis of LV, Standard deviation (SD), width of half maximum of phase angle (FWHM), and range of phase angle were significantly increased in patients with C-LBBB than in controls (20.6 + 18.1 vs S.6 + I.8, 22. 5 + 9.2 vs 16.0 + 3.9, 95.7 + 31.7 vs 51.3 + 5.4, respectively, p<0.05). 3) There was no significant difference in EF, PER, PFR between patients with the WolffParkinson-White syndrome and controls. 4) Standard deviation and range of phase angle were significantly higher in patients with WPW syndrome than in controls (10.6 + 2.6 vs 8.6 + 1.8, p<0.05, 69.8 + 11.7 vs 51.3 + 5 4, p<0.001, respectively), however, there was no difference between the two groups in full width of half maximum. 5) Phase image analysis revealed relatively uniform phase across the both ventriles in patients with normal conduction, but markedly delayed phase in the left ventricle

  6. Retrofit implementation of Zernike phase plate imaging for cryo-TEM.

    Science.gov (United States)

    Marko, Michael; Leith, Ardean; Hsieh, Chyongere; Danev, Radostin

    2011-05-01

    In-focus phase-plate imaging is particularly beneficial for cryo-TEM because it offers a substantial overall increase in image contrast, without an electron dose penalty, and it simplifies image interpretation. We show how phase-plate cryo-TEM can be implemented with an appropriate existing TEM, and provide a basic practical introduction to use of thin-film (carbon) phase plates. We point out potential pitfalls of phase-plate operation, and discuss solutions. We provide information on evaluating a particular TEM for its suitability. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Interpretation of Scintigraphic Changes during Chronic Hepatitis and Cirrhosis of the Liver

    Energy Technology Data Exchange (ETDEWEB)

    Gheorghescu, B.; Jovin, G.; Pavel, D.; Hoanca, O.; Marculescu, Lidia; Suseanu, I.; Sparchez, T. [Centre of Gastroenterology, Bucharest (Romania)

    1969-05-15

    Photoscintigrams in black and white and in colour were made of the liver and the hepatic clearance was determined by colloidal {sup 198}Au (dimensions 25 - 30 {mu}m) in 82 patients suffering from chronic hepatitis or cirrhosis confirmed by clinical, humeral and histological criteria. The most characteristic changes in the liver scintigram, found particularly in the cirrhosis patients, were: atrophy of the right lobe (partial or total), sometimes pseudo tumoral in appearance; pale or in- homogeneous left lobe; presence of two centres of maximum radiocolloid uptake (left lobe and right lobe); and extrahepatic fixation (spleen, bone marrow). The colour recording system provided better information than the monochromatic system in the diagnosis of cirrhosis. Hepatic clearance showed a decrease, especially in cases of cirrhosis characterized by extrahepatic uptake of the radiocolloid. In the opinion of the authors, the height of the radioactivity curve registered in the temporal region is an indication, during the stabilization phase, of extrahepatic fixation of the colloidal gold. Its height (h{sub 2}) is greater in those cases where the scintigram indicated higher uptake in the spleen and bone marrow. The T 1/2 study of {sup 51}Cr-labelled erythrocytes and their sequestration in the spleen was made in 30 patients exhibiting increased extrahepatic uptake of colloidal gold. The sequestration of labelled erythrocytes was observed in patients showing large-scale splenic uptake of the radiocolloid. Some of the patients whose photoscintigrams previously showed atrophy of the lower region of the right lobe of the liver and obvious presence of the spleen received injections of colloidal gold in the spleen. After intrasplenic injection, the authors obtained the same scintigraphic image in cirrhosis patients, with persistence of the colloidal gold in the spleen, whereas the image of the spleen remained normal in normal subjects. This proves the existence of a lamellar

  8. Simultaneous acquisition of dual analyser-based phase contrast X-ray images for small animal imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Pavlov, Konstantin M.; Hooper, Stuart B.; Vine, David J.; Siu, Karen K.W.; Wallace, Megan J.; Siew, Melissa L.L.; Yagi, Naoto; Uesugi, Kentaro; Lewis, Rob A.

    2008-01-01

    Analyser-based phase contrast X-ray imaging can provide high-contrast images of biological tissues with exquisite sensitivity to the boundaries between tissues. The phase and absorption information can be extracted by processing multiple images acquired at different analyser orientations. Recording both the transmitted and diffracted beams from a thin Laue analyser crystal can make phase retrieval possible for dynamic systems by allowing full field imaging. This technique was used to image the thorax of a mechanically ventilated newborn rabbit pup using a 25 keV beam from the SPring-8 synchrotron radiation facility. The diffracted image was produced from the (1 1 1) planes of a 50 mm x 40 mm, 100 μm thick Si analyser crystal in the Laue geometry. The beam and analyser were large enough to image the entire chest, making it possible to observe changes in anatomy with high contrast and spatial resolution

  9. Simultaneous acquisition of dual analyser-based phase contrast X-ray images for small animal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kitchen, Marcus J. [School of Physics, Monash University, Victoria 3800 (Australia)], E-mail: Marcus.Kitchen@sci.monash.edu.au; Pavlov, Konstantin M. [School of Physics, Monash University, Victoria 3800 (Australia); Monash Centre for Synchrotron Science, Monash University, Victoria 3800 (Australia); Physics and Electronics, School of Science and Technology, University of New England, NSW 2351 (Australia)], E-mail: Konstantin.Pavlov@sci.monash.edu.au; Hooper, Stuart B. [Department of Physiology, Monash University, Victoria 3800 (Australia)], E-mail: Stuart.Hooper@med.monash.edu.au; Vine, David J. [School of Physics, Monash University, Victoria 3800 (Australia)], E-mail: David.Vine@sci.monash.edu.au; Siu, Karen K.W. [School of Physics, Monash University, Victoria 3800 (Australia); Monash Centre for Synchrotron Science, Monash University, Victoria 3800 (Australia)], E-mail: Karen.Siu@sci.monash.edu.au; Wallace, Megan J. [Department of Physiology, Monash University, Victoria 3800 (Australia)], E-mail: Megan.Wallace@med.monash.edu.au; Siew, Melissa L.L. [Department of Physiology, Monash University, Victoria 3800 (Australia)], E-mail: Melissa.Siew@med.monash.edu.au; Yagi, Naoto [SPring-8/JASRI, Sayo (Japan)], E-mail: yagi@spring8.or.jp; Uesugi, Kentaro [SPring-8/JASRI, Sayo (Japan)], E-mail: ueken@spring8.or.jp; Lewis, Rob A. [School of Physics, Monash University, Victoria 3800 (Australia); Monash Centre for Synchrotron Science, Monash University, Victoria 3800 (Australia)], E-mail: Rob.Lewis@sync.monash.edu.au

    2008-12-15

    Analyser-based phase contrast X-ray imaging can provide high-contrast images of biological tissues with exquisite sensitivity to the boundaries between tissues. The phase and absorption information can be extracted by processing multiple images acquired at different analyser orientations. Recording both the transmitted and diffracted beams from a thin Laue analyser crystal can make phase retrieval possible for dynamic systems by allowing full field imaging. This technique was used to image the thorax of a mechanically ventilated newborn rabbit pup using a 25 keV beam from the SPring-8 synchrotron radiation facility. The diffracted image was produced from the (1 1 1) planes of a 50 mm x 40 mm, 100 {mu}m thick Si analyser crystal in the Laue geometry. The beam and analyser were large enough to image the entire chest, making it possible to observe changes in anatomy with high contrast and spatial resolution.

  10. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  11. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  12. Acute rhabdomyolysis of the soleus muscle induced by a lightning strike: magnetic resonance and scintigraphic findings

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Naofumi; Inaoka, Tsutomu; Shuke, Noriyuki; Takahashi, Koji; Aburano, Tamio [Asahikawa Medical College, Department of Radiology, Asahikawa (Japan); Chisato, Naoyuki; Go, Kazutomo [Asahikawa Medical College, Department of Emergency Medicine, Asahikawa (Japan); Nochi, Hitoshi [Asahikawa Medical College, Department of Orthopaedic Surgery, Asahikawa (Japan)

    2007-07-15

    Among natural disasters, a lightning strike is a rare but potentially life-threatening phenomenon. If victims survive a cardiac arrest due to instantaneous passage of an exceptionally high voltage electric charge through the whole body, they may be afflicted with various complications such as muscle necrosis resulting in acute renal failure. In this article, we report a case of a 54-year-old man with acute rhabdomyolysis of the left soleus muscle associated with a lightning strike. T2-weighted and short-tau inversion recovery MR images showed a high signal intensity in the left soleus muscle. A whole-body bone scintigram showed abnormal uptakes in the left soleus muscle and the dorsal aspect of the left foot. MR and scintigraphic evaluations were very useful in depicting the site and extent of muscle damage. Since the patient showed a surprisingly high level of serum creatine kinase, the added information was very valuable for determining the patient's management. (orig.)

  13. Acute rhabdomyolysis of the soleus muscle induced by a lightning strike: magnetic resonance and scintigraphic findings

    International Nuclear Information System (INIS)

    Watanabe, Naofumi; Inaoka, Tsutomu; Shuke, Noriyuki; Takahashi, Koji; Aburano, Tamio; Chisato, Naoyuki; Go, Kazutomo; Nochi, Hitoshi

    2007-01-01

    Among natural disasters, a lightning strike is a rare but potentially life-threatening phenomenon. If victims survive a cardiac arrest due to instantaneous passage of an exceptionally high voltage electric charge through the whole body, they may be afflicted with various complications such as muscle necrosis resulting in acute renal failure. In this article, we report a case of a 54-year-old man with acute rhabdomyolysis of the left soleus muscle associated with a lightning strike. T2-weighted and short-tau inversion recovery MR images showed a high signal intensity in the left soleus muscle. A whole-body bone scintigram showed abnormal uptakes in the left soleus muscle and the dorsal aspect of the left foot. MR and scintigraphic evaluations were very useful in depicting the site and extent of muscle damage. Since the patient showed a surprisingly high level of serum creatine kinase, the added information was very valuable for determining the patient's management. (orig.)

  14. Transverse Oscillations for Phased Array Vector Velocity Imaging

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes; Jensen, Jørgen Arendt

    2010-01-01

    of superficial blood vessels. To broaden the usability of the method, it should be expanded to a phased array geometry enabling vector velocity imaging of the heart. Therefore, the scan depth has to be increased to 10-15 cm. This paper presents suitable pulse echo fields (PEF). Two lines are beamformed...... (correlation coefficient, R: -0.76), and therefore predict estimator performance. CV is correlated with the standard deviation (R=0.74). The results demonstrate the potential for using a phased array for vector velocity imaging at larger depths, and potentially for imaging the heart....

  15. Combined scintigraphic and radiographic diagnosis of bone and joint diseases. Including gamma correction interpretation. 4. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong-Whee [Sung Ae General Hospital, Seoul (Korea, Republic of). Dept. of Nuclear Medicine and Radiology

    2013-07-01

    In this fourth edition of Combined Scintigraphic and Radiographic Diagnosis of Bone and Joint Diseases, the text has been thoroughly amended, updated, and partially rearranged to reflect the latest advances. In addition to discussing the role of pinhole imaging in the range of disorders previously covered, the new edition pays detailed attention to the novel diagnostic use of gamma correction pinhole bone scan in a broad spectrum of skeletal disorders, including physical, traumatic, and sports injuries, infectious and non-infectious bone diseases, benign and malignant bone tumors, and soft tissue diseases. A large number of state of the art pinhole scans and corroborative CT, MRI, and/or ultrasound images are presented side by side. The book has been enlarged to encompass various new topics, including occult fractures; cervical sprain and whiplash trauma; bone marrow edema; microfractures of trabeculae; evident, gaping, and stress fractures; and differential diagnosis. This new edition will be essential reading for practitioners and researchers in not only nuclear medicine but also radiology, orthopedic surgery, and pathology.

  16. Combined scintigraphic and radiographic diagnosis of bone and joint diseases. Including gamma correction interpretation. 4. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Bahk, Yong-Whee

    2013-01-01

    In this fourth edition of Combined Scintigraphic and Radiographic Diagnosis of Bone and Joint Diseases, the text has been thoroughly amended, updated, and partially rearranged to reflect the latest advances. In addition to discussing the role of pinhole imaging in the range of disorders previously covered, the new edition pays detailed attention to the novel diagnostic use of gamma correction pinhole bone scan in a broad spectrum of skeletal disorders, including physical, traumatic, and sports injuries, infectious and non-infectious bone diseases, benign and malignant bone tumors, and soft tissue diseases. A large number of state of the art pinhole scans and corroborative CT, MRI, and/or ultrasound images are presented side by side. The book has been enlarged to encompass various new topics, including occult fractures; cervical sprain and whiplash trauma; bone marrow edema; microfractures of trabeculae; evident, gaping, and stress fractures; and differential diagnosis. This new edition will be essential reading for practitioners and researchers in not only nuclear medicine but also radiology, orthopedic surgery, and pathology.

  17. Scintigraphic detection of coronary artery thrombi in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Fox, K.A.; Bergmann, S.R.; Mathias, C.J.; Powers, W.J.; Siegel, B.A.; Welch, M.J.; Sobel, B.E.

    1984-01-01

    To determine whether coronary thrombi can be detected scintigraphically after acute myocardial infarction, 24 patients were studied with a new method employing indium-111-labeled platelets and technetium-99m-labeled red blood cells. Nine patients with suspected infarction were evaluated initially within 9 hours of the onset of symptoms and again 18 to 24 hours after onset. Foci of net indium accumulation were detected after image processing that incorporated subtraction of blood pool activity. Carotid and pulmonary artery reference regions, in which blood pool activity is high and active platelet deposition unlikely, were used to correct digitized cardiac scintigrams for indium-111 platelet activity in the blood pool. In patients with infarction, distinct foci of net indium accumulation were present in regions corresponding to the coronary artery supplying ischemic zones. This occurred in seven of eight patients at the time of the earliest evaluation after the onset of symptoms) and in eight of nine patients at the time of subsequent imaging (23.6 +/- 1.9 hours after onset). Only 1 of 15 control patients exhibited a cardiac focus of net indium accumulation. The percent of indium excess (100 [total indium-111 activity-blood pool indium-111 activity]/blood pool indium-111 activity) within the cardiac region measured (+/- SD) 16.8 +/- 11.6% in all patients with myocardial infarction (19.1 +/- 11.2% in those with visually identified foci) compared with 0.4 +/- 4.3% in control patients. This method permits early detection and sequential assessment of coronary artery thrombi

  18. Diagnosis of the three-phase induction motor using thermal imaging

    Science.gov (United States)

    Glowacz, Adam; Glowacz, Zygfryd

    2017-03-01

    Three-phase induction motors are used in the industry commonly for example woodworking machines, blowers, pumps, conveyors, elevators, compressors, mining industry, automotive industry, chemical industry and railway applications. Diagnosis of faults is essential for proper maintenance. Faults may damage a motor and damaged motors generate economic losses caused by breakdowns in production lines. In this paper the authors develop fault diagnostic techniques of the three-phase induction motor. The described techniques are based on the analysis of thermal images of three-phase induction motor. The authors analyse thermal images of 3 states of the three-phase induction motor: healthy three-phase induction motor, three-phase induction motor with 2 broken bars, three-phase induction motor with faulty ring of squirrel-cage. In this paper the authors develop an original method of the feature extraction of thermal images MoASoID (Method of Areas Selection of Image Differences). This method compares many training sets together and it selects the areas with the biggest changes for the recognition process. Feature vectors are obtained with the use of mentioned MoASoID and image histogram. Next 3 methods of classification are used: NN (the Nearest Neighbour classifier), K-means, BNN (the back-propagation neural network). The described fault diagnostic techniques are useful for protection of three-phase induction motor and other types of rotating electrical motors such as: DC motors, generators, synchronous motors.

  19. Optical double-image cryptography based on diffractive imaging with a laterally-translated phase grating.

    Science.gov (United States)

    Chen, Wen; Chen, Xudong; Sheppard, Colin J R

    2011-10-10

    In this paper, we propose a method using structured-illumination-based diffractive imaging with a laterally-translated phase grating for optical double-image cryptography. An optical cryptosystem is designed, and multiple random phase-only masks are placed in the optical path. When a phase grating is laterally translated just before the plaintexts, several diffraction intensity patterns (i.e., ciphertexts) can be correspondingly obtained. During image decryption, an iterative retrieval algorithm is developed to extract plaintexts from the ciphertexts. In addition, security and advantages of the proposed method are analyzed. Feasibility and effectiveness of the proposed method are demonstrated by numerical simulation results. © 2011 Optical Society of America

  20. Scintigraphic findings in amoebic abscess of the liver

    International Nuclear Information System (INIS)

    Buenemann, H.; Petersen, F.; Mohr, W.

    1976-01-01

    The accuracy, size, localization and course of liver scans of solitary or multiple amoebic liver abscesses was evaluated in 52 patients. The scintigraphic data were correlated with the clinical symptoms. In 47 of the 52 patients it was possible to demonstrate the liver abscess on the scintigram; the right lobe of the liver was involved more frequently than would have been expected simply on the basis of its volume. In most of the patients investigated the abscesses were solitary and in only 28% it was possible to recognise two or three abscesses occurring simultaneously. Follow-up examinations showed rapid diminution in the size of the abscess during medical treatment, but complete return to normal during the first six months occured in only 17% of cases. The results are discussed. (orig.) [de

  1. Epiphyseal involvement in Erdheim-Chester disease: radiographic and scintigraphic findings in a case with lytic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Hernandez, G.; Tajahuerce-Romera, G.M.; Latorre-Ibanez, M.D.; Lara-Pomares, A. [Servicio de Medicina Nuclear, Hospital Provincial de Castellon (Spain); Vila-Fayos, V. [Servicio de Reumatologia, Hospital Comarcal de Vinaroz (Spain)

    2000-08-01

    We reported a symmetric increase of activity in lower links secondary to Erdheim-Chester disease and demonstrated by bone scans and radiographs. An inusual scintigraphic and radiographic appearance with epiphyseal involvement and lytic lesions is described. Differential diagnosis of bone scan and radiographic findings is discussed. (orig.)

  2. Optical colour image watermarking based on phase-truncated linear canonical transform and image decomposition

    Science.gov (United States)

    Su, Yonggang; Tang, Chen; Li, Biyuan; Lei, Zhenkun

    2018-05-01

    This paper presents a novel optical colour image watermarking scheme based on phase-truncated linear canonical transform (PT-LCT) and image decomposition (ID). In this proposed scheme, a PT-LCT-based asymmetric cryptography is designed to encode the colour watermark into a noise-like pattern, and an ID-based multilevel embedding method is constructed to embed the encoded colour watermark into a colour host image. The PT-LCT-based asymmetric cryptography, which can be optically implemented by double random phase encoding with a quadratic phase system, can provide a higher security to resist various common cryptographic attacks. And the ID-based multilevel embedding method, which can be digitally implemented by a computer, can make the information of the colour watermark disperse better in the colour host image. The proposed colour image watermarking scheme possesses high security and can achieve a higher robustness while preserving the watermark’s invisibility. The good performance of the proposed scheme has been demonstrated by extensive experiments and comparison with other relevant schemes.

  3. Experimental validation of the Wigner distributions theory of phase-contrast imaging

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2005-01-01

    Recently, a new theory of phase-contrast imaging has been proposed by Wu and Liu [Med. Phys. 31, 2378-2384 (2004)]. This theory, based upon Wigner distributions, provides a much stronger foundation for the evaluation of phase-contrast imaging systems than did the prior theories based upon Fresnel-Kirchhoff diffraction theory. In this paper, we compare results of measurements made in our laboratory of phase contrast for different geometries and tube voltages to the predictions of the Wu and Liu model. In our previous publications, we have used an empirical measurement (the edge enhancement index) to parametrize the degree of phase-contrast effects in an image. While the Wu and Liu model itself does not predict image contrast, it does measure the degree of phase contrast that the system can image for a given spatial frequency. We have found that our previously published experimental results relating phase-contrast effects to geometry and x-ray tube voltage are consistent with the predictions of the Wu and Liu model

  4. Phase Imaging: A Compressive Sensing Approach

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Sebastian; Stevens, Andrew; Browning, Nigel D.; Pohl, Darius; Nielsch, Kornelius; Rellinghaus, Bernd

    2017-07-01

    Since Wolfgang Pauli posed the question in 1933, whether the probability densities |Ψ(r)|² (real-space image) and |Ψ(q)|² (reciprocal space image) uniquely determine the wave function Ψ(r) [1], the so called Pauli Problem sparked numerous methods in all fields of microscopy [2, 3]. Reconstructing the complete wave function Ψ(r) = a(r)e-iφ(r) with the amplitude a(r) and the phase φ(r) from the recorded intensity enables the possibility to directly study the electric and magnetic properties of the sample through the phase. In transmission electron microscopy (TEM), electron holography is by far the most established method for phase reconstruction [4]. Requiring a high stability of the microscope, next to the installation of a biprism in the TEM, holography cannot be applied to any microscope straightforwardly. Recently, a phase retrieval approach was proposed using conventional TEM electron diffractive imaging (EDI). Using the SAD aperture as reciprocal-space constraint, a localized sample structure can be reconstructed from its diffraction pattern and a real-space image using the hybrid input-output algorithm [5]. We present an alternative approach using compressive phase-retrieval [6]. Our approach does not require a real-space image. Instead, random complimentary pairs of checkerboard masks are cut into a 200 nm Pt foil covering a conventional TEM aperture (cf. Figure 1). Used as SAD aperture, subsequently diffraction patterns are recorded from the same sample area. Hereby every mask blocks different parts of gold particles on a carbon support (cf. Figure 2). The compressive sensing problem has the following formulation. First, we note that the complex-valued reciprocal-space wave-function is the Fourier transform of the (also complex-valued) real-space wave-function, Ψ(q) = F[Ψ(r)], and subsequently the diffraction pattern image is given by |Ψ(q)|2 = |F[Ψ(r)]|2. We want to find Ψ(r) given a few differently coded diffraction pattern measurements yn

  5. Phase Image Analysis in Conduction Disturbance Patients

    International Nuclear Information System (INIS)

    Kwark, Byeng Su; Choi, Si Wan; Kang, Seung Sik; Park, Ki Nam; Lee, Kang Wook; Jeon, Eun Seok; Park, Chong Hun

    1994-01-01

    It is known that the normal His-Purkinje system provides for nearly synchronous activation of right (RV) and left (LV) ventricles. When His-Purkinje conduction is abnormal, the resulting sequence of ventricular contraction must be correspondingly abnormal. These abnormal mechanical consequences were difficult to demonstrate because of the complexity and the rapidity of its events. To determine the relationship of the phase changes and the abnormalities of ventricular conduction, we performed phase image analysis of Tc-RBC gated blood pool scintigrams in patients with intraventricular conduction disturbances (24 complete left bundle branch block (C-LBBB), 15 complete right bundle branch block (C-RBBB), 13 Wolff-Parkinson-White syndrome (WPW), 10 controls). The results were as follows; 1) The ejection fraction (EF), peak ejection rate (PER), and peak filling rate (PFR) of LV in gated blood pool scintigraphy (GBPS) were significantly lower in patients with C-LBBB than in controls (44.4 ± 13.9% vs 69.9 ± 4.2%, 2.48 ± 0.98 vs 3.51 ± 0,62, 1.76 ± 0.71 vs 3.38 ± 0.92, respectively, p<0.05). 2) In the phase angle analysis of LV, Standard deviation (SD), width of half maximum of phase angle (FWHM), and range of phase angle were significantly increased in patients with C-LBBB than in controls (20.6 + 18.1 vs S.6 + I.8, 22. 5 + 9.2 vs 16.0 + 3.9, 95.7 + 31.7 vs 51.3 + 5.4, respectively, p<0.05). 3) There was no significant difference in EF, PER, PFR between patients with the WolffParkinson-White syndrome and controls. 4) Standard deviation and range of phase angle were significantly higher in patients with WPW syndrome than in controls (10.6 + 2.6 vs 8.6 + 1.8, p<0.05, 69.8 + 11.7 vs 51.3 + 5 4, p<0.001, respectively), however, there was no difference between the two groups in full width of half maximum. 5) Phase image analysis revealed relatively uniform phase across the both ventriles in patients with normal conduction, but markedly delayed phase in the left ventricle

  6. Technetium-99m biliary imaging in pediatric surgical problems

    International Nuclear Information System (INIS)

    Sty, J.R.; Glicklich, M.; Babbitt, D.P.; Starshak, R.J.

    1981-01-01

    The results of scintigraphic imaging of the hepatobiliary system with 99mTc-PIPIDA (IDA derivative p-isopropylacetanilidoiminodiacetic acid) in forty children are reported. 99mTc-PIPIDA imaging is a noninvasive, rapid, safe examination that provides both functional and anatomical information about the hepatobiliary system. Although interpretation is limited by elevated direct serum bilirubin, this agent allows diagnostic information to be obtained with direct serum bilirubin levels up to 8 mg/dl

  7. Triple-phase bone image abnormalities in Lyme arthritis

    International Nuclear Information System (INIS)

    Brown, S.J.; Dadparvar, S.; Slizofski, W.J.; Glab, L.B.; Burger, M.

    1989-01-01

    Arthritis is a frequent manifestation of Lyme disease. Limited triple-phase Tc-99m MDP bone imaging of the wrists and hands with delayed whole-body images was performed in a patient with Lyme arthritis. This demonstrated abnormal joint uptake in the wrists and hands in all three phases, with increased activity seen in other affected joints on delayed whole-body images. These findings are nonspecific and have been previously described in a variety of rheumatologic conditions, but not in Lyme disease. Lyme disease should be considered in the differential diagnosis of articular and periarticular bone scan abnormalities

  8. GPC and quantitative phase imaging

    DEFF Research Database (Denmark)

    Palima, Darwin; Banas, Andrew Rafael; Villangca, Mark Jayson

    2016-01-01

    shaper followed by the potential of GPC for biomedical and multispectral applications where we experimentally demonstrate the active light shaping of a supercontinuum laser over most of the visible wavelength range. Finally, we discuss how GPC can be advantageously applied for Quantitative Phase Imaging...

  9. Four-dimensional dose reconstruction through in vivo phase matching of cine images of electronic portal imaging device.

    Science.gov (United States)

    Yoon, Jihyung; Jung, Jae Won; Kim, Jong Oh; Yi, Byong Yong; Yeo, Inhwan

    2016-07-01

    A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume of the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as "reference" images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the time of planning CT was

  10. Four-dimensional dose reconstruction through in vivo phase matching of cine images of electronic portal imaging device

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jihyung; Jung, Jae Won, E-mail: jungj@ecu.edu [Department of Physics, East Carolina University, Greenville, North Carolina 27858 (United States); Kim, Jong Oh [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania 15232 (United States); Yi, Byong Yong [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 (United States); Yeo, Inhwan [Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California 92354 (United States)

    2016-07-15

    Purpose: A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). Methods: (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume of the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as “reference” images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the

  11. Nuclear medicine for diagnosis in benign diseases of the skeleton

    International Nuclear Information System (INIS)

    Feine, U.

    1992-01-01

    In summary, the lecture presents today's state of nuclear medical diganostics in benign bone disease, the radiopharmaceuticals, and the methods used. Besides the 99 m-Tc-labeled diphosphonates a couple of additional radioactive labeled substances play an important part in bone scintigraphic imaging especially in scanning inflammatory bone disease and the bone marrow. There are several substances available to label leucocytes and human immunoglobulins. Concerning the methods the performance of the 3-phase bone scanning and the application of SPECT becomes increasingly important. In detail discussed are among other methods the inflammation-scanning in osteomyelitis, the scintigraphic imaging in benign bone tumors and tumor like lesions, in circulation disorders of the bone with necroses and hyperperfusion (reflex sympathetic dystrophy, transient hip osteoporosis), and in bone lesions following trauma or stress, for example also in battered child syndrome. The indication to the different imaging procedures as X-ray, computed tomography, nuclear magnetic resonance, and scintigraphic imaging are discussed, whereby the scintiscanning urges its place, mainly due to good specifity, in documenting the different functional states of the bone such as inflammation, perfusion, necrosis, tumor and/or bone marrow infiltration. (orig.) [de

  12. Scintigraphic test of the vitality and functional fitness of organs conserved for transplantation

    International Nuclear Information System (INIS)

    Bozduganov, A.; Marinov, V.

    1976-01-01

    Having reviewed critically present-day methods of testing the vitality of isolated perfused organs, the authors propose their own. It is founded in the principles of colour scintigraphy after introduction of short-lived nuclides. The method was applied in testing 57 isolated preserved organs (5 kidneys, 12 livers, 5 hearts and 4 spleens from dogs; 2 kidneys and 27 livers from rabbits; 1 kidney and 1 liver from young pigs). Moreover, compararive scintigraphic and biochemical investigations were conducted on 2 dogs and 4 young pigs (A. Bozduganov, E. Simeonov, N. Bogdanova). The techniques of isolation and perfusion of the organ have been given a detailed description. Sup(113m)In was used as tracer. Areas of radioactivity deposits were visualized more or less intensely, depending on the degree of vitality and functional fitness still present actually; else, blanks were seen. Orthotransplantation and heterotransplantation with subsequent scintigraphic examination in vivo served, in scattered instances, the purpose of confirming or of rejecting ambiguous vitality findings in preserved organs. Advantages of the method are a general and specified evaluation of the organ in all of its areas; anatomical integrity of the object under test; applicability to various organs; possibility of conducting dynamic tests; accurate reproduction of vitality and functional findings, etc

  13. Quantitative differential phase contrast imaging at high resolution with radially asymmetric illumination.

    Science.gov (United States)

    Lin, Yu-Zi; Huang, Kuang-Yuh; Luo, Yuan

    2018-06-15

    Half-circle illumination-based differential phase contrast (DPC) microscopy has been utilized to recover phase images through a pair of images along multiple axes. Recently, the half-circle based DPC using 12-axis measurements significantly provides a circularly symmetric phase transfer function to improve accuracy for more stable phase recovery. Instead of using half-circle-based DPC, we propose a new scheme of DPC under radially asymmetric illumination to achieve circularly symmetric phase transfer function and enhance the accuracy of phase recovery in a more stable and efficient fashion. We present the design, implementation, and experimental image data demonstrating the ability of our method to obtain quantitative phase images of microspheres, as well as live fibroblast cell samples.

  14. In vivo comparative study of hydroxyapatite labeled with different radioisotopes: evaluation of the scintigraphic images

    International Nuclear Information System (INIS)

    Couto, Renata Martinussi; Barboza, Marycel Figols de; Souza, Adriano Aparecido de; Muramoto, Emiko; Mengatti, Jair; Araujo, Elaine Bortoleti de

    2008-01-01

    Rheumatoid arthritis (RA) is a chronic inflammatory disorder of joints that is characterized by the inflammation and proliferation of synovial tissues. Approximately 3% of the adult population in the world is affected by this disease which causes pain, joint immobility and disability. Adyo synovectomy (RSV) is a radiotherapeutic modality where a b--emitting radionuclide is administered locally by intra-articular injection on the form of a colloid or radiolabeled particulate. RSV is a well-accepted therapeutic procedure in inflammatory joint diseases and has been successfully employed for more than 50 years as a viable alternative to surgical and chemical synovectomy in the treatment of RA and other inflammatory arthropathies. There are several radionuclides available for this purpose such as 177 Lu, 90 Y, 153 Sm, 165 Dy, and 166 Ho. Hydroxyapatite (HA) is one of the preferred particulates for this application because it is the major chemical constituent of skeletal bone and it is converted into Ca and PO4 ions in the body. In addition HA is completely eliminated over a period of six weeks. The aim of this work is to compare the in vivo stability of hydroxyapatite labeled with 177 Lu, 90 Y and 153 Sm in order to determine the influence of the radionuclide on biological pattern. In biological studies, 100mL of labeled HAs suspended in normal saline were injected into normal knee joints of Wistar rats and the retention of the activity into the synovium was determined. Labeled particles were also injected by intravenous and intramuscular administration, to verify the biodistribution in the case of an eventual leakage of the products from the joint. Sequential scintigraphic images were acquired from 1 hour to 7 days p.i. after anesthetizing the animals with ketamine. Hydroxyapatite was radiolabeled by all radionuclides with high yield. 177 Lu-HA, 90 Y-HA and 153 Sm-HA were retained in the joint for 7 days, showing stability and usefulness as tools in the RSV treatment

  15. Measurements of liquid-phase turbulence in gas–liquid two-phase flows using particle image velocimetry

    International Nuclear Information System (INIS)

    Zhou, Xinquan; Doup, Benjamin; Sun, Xiaodong

    2013-01-01

    Liquid-phase turbulence measurements were performed in an air–water two-phase flow loop with a circular test section of 50 mm inner diameter using a particle image velocimetry (PIV) system. An optical phase separation method-–planar laser-induced fluorescence (PLIF) technique—which uses fluorescent particles and an optical filtration technique, was employed to separate the signals of the fluorescent seeding particles from those due to bubbles and other noises. An image pre-processing scheme was applied to the raw PIV images to remove the noise residuals that are not removed by the PLIF technique. In addition, four-sensor conductivity probes were adopted to measure the radial distribution of the void fraction. Two benchmark tests were performed: the first was a comparison of the PIV measurement results with those of similar flow conditions using thermal anemometry from previous studies; the second quantitatively compared the superficial liquid velocities calculated from the local liquid velocity and void fraction measurements with the global liquid flow rate measurements. The differences of the superficial liquid velocity obtained from the two measurements were bounded within ±7% for single-phase flows and two-phase bubbly flows with the area-average void fraction up to 18%. Furthermore, a preliminary uncertainty analysis was conducted to investigate the accuracy of the two-phase PIV measurements. The systematic uncertainties due to the circular pipe curvature effects, bubble surface reflection effects and other potential uncertainty sources of the PIV measurements were discussed. The purpose of this work is to facilitate the development of a measurement technique (PIV-PLIF) combined with image pre-processing for the liquid-phase turbulence in gas–liquid two-phase flows of relatively high void fractions. The high-resolution data set can be used to more thoroughly understand two-phase flow behavior, develop liquid-phase turbulence models, and assess high

  16. Clinical evaluation of left ventricular wall thickness by combined technique with gated planer 201Tl image and gated cardiac pool image

    International Nuclear Information System (INIS)

    Nakai, Kenji; Katsuragawa, Shigehiko; Takahashi, Tsuneo; Matsushita, Kazuo; Kawamura, Akiyoshi

    1983-01-01

    To evaluate the left ventricular (LV) wall thickness, combined technique with gated planer 201-Thallium image and gated cardiac pool image was applied to 6 patients with hypertrophic cardiomyopathy (HCM) and 4 patients with secondary hypertrophy due to hypertension (HHD) proven by electrocardiography and ultrasonic-echocardiography. Scintigraphic pattern of hypertrophy on reconstructed planer 201 Tl image showed diffuse or asymmetrical apical hypertrophy in HHD, asymmetrical septal hypertrophy in HCM. It was very interesting that abnormal perfusion was shown in 201 Tl image, despite symmetrical hypertrophy in echocardiography. This techniques provided useful information for evaluating the LV wall thickness and cardiac performance. (author)

  17. Hard-x-ray phase-imaging microscopy using the self-imaging phenomenon of a transmission grating

    International Nuclear Information System (INIS)

    Yashiro, Wataru; Harasse, Sebastien; Momose, Atsushi; Takeuchi, Akihisa; Suzuki, Yoshio

    2010-01-01

    We report on a hard-x-ray imaging microscope consisting of a lens, a sample, and a transmission grating. After the theoretical framework of self-imaging phenomenon by the grating in the system is presented, equations for the electric field on the image plane are derived for ideal and real lenses and an equation for the intensity on the image plane for partially coherent illumination is derived. The equations are simple and similar to those applying to a projection microscope consisting of a transmission grating except that there is no defocusing effect, regardless of whether the grating is in front of or behind the lens. This means that x-ray phase-imaging microscopy can be done without the defocusing effect. It is also shown that, by resolving the self-image on the image plane, high-sensitive x-ray phase-imaging microscopy can be attained without degradation in the spatial resolution due to diffraction by the grating. Experimental results obtained using partially coherent illumination from a synchrotron x-ray source confirm that hard-x-ray phase-imaging microscopy can be quantitatively performed with high sensitivity and without the spatial resolution degradation.

  18. In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science.

    Science.gov (United States)

    Mayo, Sheridan C; Stevenson, Andrew W; Wilkins, Stephen W

    2012-05-24

    X-ray phase-contrast imaging and tomography make use of the refraction of X-rays by the sample in image formation. This provides considerable additional information in the image compared to conventional X-ray imaging methods, which rely solely on X-ray absorption by the sample. Phase-contrast imaging highlights edges and internal boundaries of a sample and is thus complementary to absorption contrast, which is more sensitive to the bulk of the sample. Phase-contrast can also be used to image low-density materials, which do not absorb X-rays sufficiently to form a conventional X-ray image. In the context of materials science, X-ray phase-contrast imaging and tomography have particular value in the 2D and 3D characterization of low-density materials, the detection of cracks and voids and the analysis of composites and multiphase materials where the different components have similar X-ray attenuation coefficients. Here we review the use of phase-contrast imaging and tomography for a wide variety of materials science characterization problems using both synchrotron and laboratory sources and further demonstrate the particular benefits of phase contrast in the laboratory setting with a series of case studies.

  19. Scintigraphic assessment of colostomy irrigation.

    Science.gov (United States)

    Christensen, P.; Olsen, N.; Krogh, K.; Laurberg, S.

    2002-09-01

    OBJECTIVE: This study aims to evaluate colonic transport following colostomy irrigation with a new scintigraphic technique. MATERIALS AND METHODS: To label the bowel contents 19 patients (11 uncomplicated colostomy irrigation, 8 complicated colostomy irrigation) took 111In-labelled polystyrene pellets one and two days before investigation. 99mTc-DTPA was mixed with the irrigation fluid to assess its extent within the bowel. Scintigraphy was performed before and after a standardized washout procedure. The colon was divided into three segments 1: the caecum andascending colon; 2: the transverse colon; 3: the descending and sigmoid colon. Assuming ordered evacuation of the colon, the contribution of each colonic segment to the total evacuation was expressed as a percentage of the original segmental counts. These were added to reach a total defaecation score (range: 0-300). RESULTS: In uncomplicated colostomy irrigation, the median defaecation score was 235 (range: 145-289) corresponding to complete evacuation of the descending and transverse colon and 35% evacuation of the caecum/ascending colon. In complicated colostomy irrigation it was possible to distinguish specific emptying patterns. The retained irrigation fluid reached the caecum in all but one patient. CONCLUSION: Scintigraphy can be used to evaluate colonic emptying following colostomy irrigation.

  20. Evaluation of fibrinogen-DTPA-99mTc. Biodistribution and imaging studies

    International Nuclear Information System (INIS)

    Lungu, V.; Mihailescu, G.; Fugaru, V.; Preda, A.

    1998-01-01

    Labelling with 99m Tc of fibrinogen, using DTPA anhydride as the bifunctional chelating agent, was studied in animals with venous thrombi. The parameters studied were: i) coupled reaction of 99m Tc with the fibrinogen-DTPA-Sn(II) in lyophilised form; ii) biodistribution studies of fibrinogen- 99m Tc in animals with venous thrombi, and iii) imaging studies by scintigraphic methods. The present study showed that the radiochemical purity of fibrinogen-DTPA- 99m Tc is > 95% for a maximum of 5 mCi (185 MBq) radioactivity of 99m Tc in the 1.5-2 ml volume. Above this level of radioactivity we found a drastic decrease in the radiochemical purity. The radioactivity ratio of the venous thrombi to the blood was 2.32+-0.45. The scintigraphic images showed a significant accumulation of fibrinogen-DTPA- 99m Tc in 1-hour-old thrombi, 1 hour after injection. From this results the diagnostic potential of fibrinogen-DTPA-Sn(II) in kit form was evaluated. (author)

  1. X-ray phase imaging-From static observation to dynamic observation-

    International Nuclear Information System (INIS)

    Momose, A.; Yashiro, W.; Olbinado, M. P.; Harasse, S.

    2012-01-01

    We are attempting to expand the technology of X-ray grating phase imaging/tomography to enable dynamic observation. X-ray phase imaging has been performed mainly for static cases, and this challenge is significant since properties of materials (and hopefully their functions) would be understood by observing their dynamics in addition to their structure, which is an inherent advantage of X-ray imaging. Our recent activities in combination with white synchrotron radiation for this purpose are described. Taking advantage of the fact that an X-ray grating interferometer functions with X-rays of a broad energy bandwidth (and therefore high flux), movies of differential phase images and visibility images are obtained with a time resolution of a millisecond. The time resolution of X-ray phase tomography can therefore be a second. This study is performed as a part of a project to explore X-ray grating interferometry, and our other current activities are also briefly outlined.

  2. An effective approach for iris recognition using phase-based image matching.

    Science.gov (United States)

    Miyazawa, Kazuyuki; Ito, Koichi; Aoki, Takafumi; Kobayashi, Koji; Nakajima, Hiroshi

    2008-10-01

    This paper presents an efficient algorithm for iris recognition using phase-based image matching--an image matching technique using phase components in 2D Discrete Fourier Transforms (DFTs) of given images. Experimental evaluation using CASIA iris image databases (versions 1.0 and 2.0) and Iris Challenge Evaluation (ICE) 2005 database clearly demonstrates that the use of phase components of iris images makes possible to achieve highly accurate iris recognition with a simple matching algorithm. This paper also discusses major implementation issues of our algorithm. In order to reduce the size of iris data and to prevent the visibility of iris images, we introduce the idea of 2D Fourier Phase Code (FPC) for representing iris information. The 2D FPC is particularly useful for implementing compact iris recognition devices using state-of-the-art Digital Signal Processing (DSP) technology.

  3. Estimation of clinical efficacy for scintigraphic images of liver, 1

    International Nuclear Information System (INIS)

    Matsumoto, Toru; Iinuma, Takeshi; Tateno, Yukio; Machida, Kikuo.

    1982-01-01

    In this study, the clinical efficacy No. 1 (diagnostic accuracy) of liver images on various liver diseases is investigated. From 8 different medical institutions the liver images of 406 cases most of which were imaged with 99mTc-phytate and confirmed for its final diagnosis by the autopsy, surgery and other techniques excluding the liver scintigraphy were collected. In order to evaluate the results of image reading, an input sheet for computer was designed to describe the confirmed diagnosis of each case. The liver images were read by 11 physicians from the 8 institutions that presented the cases and the results of reading were recorded on the work sheet for computer input. The work sheet includes abnormality in shape, size and position of the liver, position and number of SOL, and diagnosis of liver diseases, etc. By comparing the record of confirmed diagnosis and the results of image reading for individual case, various programs of analysis are being undertaken. The accuracy in detecting the SOL by means of receiver operating characteristic (ROC) analysis is presented here. The results of analysis are as follows. (1) ROC curves are rather similar in all physicians and average ROC points are TPR = 71, 80, 91%, FPR = 5, 15, 27%, respectively. (2) The SOL of size larger than 3 cm are detected more easily than those of size less than 3 cm, although number of SOL less than 3 cm is only nine cases and so variation of TPR between physicians is large. It is found that the ROC curve for many SOL of small size is almost identical to that of SOL larger than 3 cm. As to the detection of SOL larger than 3 cm, Anger camera and scanner are found to have an identical capability. (author)

  4. Clinical evaluation of the 99mTc-labelled myocardial imaging agent, hexakis (t-butylisonitrile)-technetium

    International Nuclear Information System (INIS)

    Liu Xiujie; Shi Rongfang; Wang Yanquen; Guo Xiuzhen; He Zuoxiang; Wang Xuebin; Liu Boli; Chinese Academy of Medical Sciences, Beijing. Div. of Nuclear Cardiology; Chinese Academy of Medical Sciences, Beijing. Cardiovascular Inst.; Beijing Normal Univ.

    1987-01-01

    99m Tc-TBI myocardial perfusion imaging has been studied in 7 normal subjects and 24 patients with coronary artery disease. Scintigraphic data revealed that 99m Tc-TBI myocardial perfusion imaging is more sensitive than ECG in detecting myocardial infarction. In comparing 99m Tc-TBI imaging with contrast angiography, its' sensitivity for the diagnosis of coronary artery disease was 91.7%. (orig.)

  5. New device based on the super spatial resolution (SSR) method

    International Nuclear Information System (INIS)

    Soluri, A.; Atzeni, G.; Ucci, A.; Bellone, T.; Cusanno, F.; Rodilossi, G.; Massari, R.

    2013-01-01

    Recently it have been described that innovative methods, namely Super Spatial Resolution (SSR), can be used to improve the scintigraphic imaging. The aim of SSR techniques is the enhancement of the resolution of an imaging system, using information from several images. In this paper we describe a new experimental apparatus that could be used for molecular imaging and small animal imaging. In fact we present a new device, completely automated, that uses the SSR method and provides images with better spatial resolution in comparison to the original resolution. Preliminary small animal imaging studies confirm the feasibility of a very high resolution system in scintigraphic imaging and the possibility to have gamma cameras using the SSR method, to perform the applications on functional imaging. -- Highlights: • Super spatial resolution brings a high resolution image from scintigraphic images. • Resolution improvement depends on the signal to noise ratio of the original images. • The SSR shows significant improvement on spatial resolution in scintigraphic images. • The SSR method is potentially utilizable for all scintigraphic devices

  6. Optical multiple-image encryption based on multiplane phase retrieval and interference

    International Nuclear Information System (INIS)

    Chen, Wen; Chen, Xudong

    2011-01-01

    In this paper, we propose a new method for optical multiple-image encryption based on multiplane phase retrieval and interference. An optical encoding system is developed in the Fresnel domain. A phase-only map is iteratively extracted based on a multiplane phase retrieval algorithm, and multiple plaintexts are simultaneously encrypted. Subsequently, the extracted phase-only map is further encrypted into two phase-only masks based on a non-iterative interference algorithm. During image decryption, the advantages and security of the proposed optical cryptosystem are analyzed. Numerical results are presented to demonstrate the validity of the proposed optical multiple-image encryption method

  7. Evaluation of quatitative scintigraphic method in diagnosis of esophagic involvement of Progressive Systemic Sclerosis

    International Nuclear Information System (INIS)

    Von Muehlen, C.A.

    1985-01-01

    Twenty patients with Progressive Systemic Sclerosis are studied by scintigraphic methodology. The esophageal transit method is used for liquid and solid meals. The results are compared with the ones of a control group, without or not gastrintestinal problems but without autoimmune diasese. 99 sup(m)Tc-sulfurcolloid is used as labelling compound. The studies were done in supine and orthostatical position. (M.A.C.) [pt

  8. Analyser-based phase contrast image reconstruction using geometrical optics.

    Science.gov (United States)

    Kitchen, M J; Pavlov, K M; Siu, K K W; Menk, R H; Tromba, G; Lewis, R A

    2007-07-21

    Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser.

  9. An imaging method of wavefront coding system based on phase plate rotation

    Science.gov (United States)

    Yi, Rigui; Chen, Xi; Dong, Liquan; Liu, Ming; Zhao, Yuejin; Liu, Xiaohua

    2018-01-01

    Wave-front coding has a great prospect in extending the depth of the optical imaging system and reducing optical aberrations, but the image quality and noise performance are inevitably reduced. According to the theoretical analysis of the wave-front coding system and the phase function expression of the cubic phase plate, this paper analyzed and utilized the feature that the phase function expression would be invariant in the new coordinate system when the phase plate rotates at different angles around the z-axis, and we proposed a method based on the rotation of the phase plate and image fusion. First, let the phase plate rotated at a certain angle around the z-axis, the shape and distribution of the PSF obtained on the image surface remain unchanged, the rotation angle and direction are consistent with the rotation angle of the phase plate. Then, the middle blurred image is filtered by the point spread function of the rotation adjustment. Finally, the reconstruction images were fused by the method of the Laplacian pyramid image fusion and the Fourier transform spectrum fusion method, and the results were evaluated subjectively and objectively. In this paper, we used Matlab to simulate the images. By using the Laplacian pyramid image fusion method, the signal-to-noise ratio of the image is increased by 19% 27%, the clarity is increased by 11% 15% , and the average gradient is increased by 4% 9% . By using the Fourier transform spectrum fusion method, the signal-to-noise ratio of the image is increased by 14% 23%, the clarity is increased by 6% 11% , and the average gradient is improved by 2% 6%. The experimental results show that the image processing by the above method can improve the quality of the restored image, improving the image clarity, and can effectively preserve the image information.

  10. Technetium-99m stannous pyrophosphate imaging of experimental infective endocarditis

    International Nuclear Information System (INIS)

    Riba, A.L.; Downs, J.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1978-01-01

    Technetium-99m stannous pyrophosphate (/sup 99m/Tc-PYP) cardiac scintigraphy was performed in 15 rabbits with experimental Streptococcus sanguis aortic-valve infective endocarditis. The animals were imaged five to seven days after the administration of bacteria, and in each case abnormal accumulation of the tracer was visualized in the region of the aortic valve. Three types of cardiac scintigraphic patterns were demonstrated: focal, multifocal, and extensive, each correlating well with the anatomical extent of the lesion as defined by gross pathology. Tissue distribution studies demonstrated a 30 +- 5.3 (mean +- SEM) fold excess of radionuclide uptake in the infective endocarditis lesion compared with that of normal myocardium. Imaging of excised hearts from four animals showed an excellent correlation with in vivo imaging as well as gross pathology. Five animals with nonbacterial thrombotic aortic valve endocarditis demonstrated similar scintigraphic and tissue distribution results. In contrast, four normal animals failed to demonstrate abnormal /sup 99m/Tc-PYP cardiac scintigrams or tissue uptake. This study demonstrates that /sup 99m/Tc-PYP cardiac scintigraphy is a sensitive technique to detect experimental aortic valve endocarditis

  11. Monte Carlo simulation of grating-based neutron phase contrast imaging at CPHS

    International Nuclear Information System (INIS)

    Zhang Ran; Chen Zhiqiang; Huang Zhifeng; Xiao Yongshun; Wang Xuewu; Wie Jie; Loong, C.-K.

    2011-01-01

    Since the launching of the Compact Pulsed Hadron Source (CPHS) project of Tsinghua University in 2009, works have begun on the design and engineering of an imaging/radiography instrument for the neutron source provided by CPHS. The instrument will perform basic tasks such as transmission imaging and computerized tomography. Additionally, we include in the design the utilization of coded-aperture and grating-based phase contrast methodology, as well as the options of prompt gamma-ray analysis and neutron-energy selective imaging. Previously, we had implemented the hardware and data-analysis software for grating-based X-ray phase contrast imaging. Here, we investigate Geant4-based Monte Carlo simulations of neutron refraction phenomena and then model the grating-based neutron phase contrast imaging system according to the classic-optics-based method. The simulated experimental results of the retrieving phase shift gradient information by five-step phase-stepping approach indicate the feasibility of grating-based neutron phase contrast imaging as an option for the cold neutron imaging instrument at the CPHS.

  12. Visualization of velocity field and phase distribution in gas-liquid two-phase flow by NMR imaging

    International Nuclear Information System (INIS)

    Matsui, G.; Monji, H.; Obata, J.

    2004-01-01

    NMR imaging has been applied in the field of fluid mechanics, mainly single phase flow, to visualize the instantaneous flow velocity field. In the present study, NMR imaging was used to visualize simultaneously both the instantaneous phase structure and velocity field of gas-liquid two-phase flow. Two methods of NMR imaging were applied. One is useful to visualize both the one component of liquid velocity and the phase distribution. This method was applied to horizontal two-phase flow and a bubble rising in stagnant oil. It was successful in obtaining some pictures of velocity field and phase distribution on the cross section of the pipe. The other is used to visualize a two-dimensional velocity field. This method was applied to a bubble rising in a stagnant water. The velocity field was visualized after and before the passage of a bubble at the measuring cross section. Furthermore, the distribution of liquid velocity was obtained. (author)

  13. Sjoegren's syndrome. A functional scintigraphic study of salivary glands

    International Nuclear Information System (INIS)

    Arrago, J.P.; Rain, J.D.; Rocher, F.; Vigneron, N.; Pecking, A.; Najean, Y.

    1984-01-01

    One-hundred and twenty patients with sicca syndrome, connective tissue disease or chronic graft-versus-host disease were investigated in the Saint-Louis Hospital Department of Nuclear Medicine. Technetium scanning of the salivary glands was performed in all patients. The results of the scintigraphic study were closely correlated with clinical and histological data in patients with Sjoegren's syndrome. This method, which accurately quantifies the salivary function without danger nor discomfort to the patients, has a number of advantages: (a) it is sensitive enough to detect minimal salivary gland dysfunction; (b) it differentiates between parotid gland and submandibular gland involvement demonstrates assymetry in pathological processes; (c) it helps in following up patients with Sjoegren's disease and in assessing the results of immunosuppressive or anti-inflammatory treatment [fr

  14. Phase contrast imaging with coherent high energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Snigireva, I. [ESRF, Grenoble (France)

    1997-02-01

    X-ray imaging concern high energy domain (>6 keV) like a contact radiography, projection microscopy and tomography is used for many years to discern the features of the internal structure non destructively in material science, medicine and biology. In so doing the main contrast formation is absorption that makes some limitations for imaging of the light density materials and what is more the resolution of these techniques is not better than 10-100 {mu}m. It was turned out that there is now way in which to overcome 1{mu}m or even sub-{mu}m resolution limit except phase contrast imaging. It is well known in optics that the phase contrast is realised when interference between reference wave front and transmitted through the sample take place. Examples of this imaging are: phase contrast microscopy suggested by Zernike and Gabor (in-line) holography. Both of this techniques: phase contrast x-ray microscopy and holography are successfully progressing now in soft x-ray region. For imaging in the hard X-rays to enhance the contrast and to be able to resolve phase variations across the beam the high degree of the time and more importantly spatial coherence is needed. Because of this it was reasonable that the perfect crystal optics was involved like Bonse-Hart interferometry, double-crystal and even triple-crystal set-up using Laue and Bragg geometry with asymmetrically cut crystals.

  15. Perceptual and statistical analysis of cardiac phase and amplitude images

    International Nuclear Information System (INIS)

    Houston, A.; Craig, A.

    1991-01-01

    A perceptual experiment was conducted using cardiac phase and amplitude images. Estimates of statistical parameters were derived from the images and the diagnostic potential of human and statistical decisions compared. Five methods were used to generate the images from 75 gated cardiac studies, 39 of which were classified as pathological. The images were presented to 12 observers experienced in nuclear medicine. The observers rated the images using a five-category scale based on their confidence of an abnormality presenting. Circular and linear statistics were used to analyse phase and amplitude image data, respectively. Estimates of mean, standard deviation (SD), skewness, kurtosis and the first term of the spatial correlation function were evaluated in the region of the left ventricle. A receiver operating characteristic analysis was performed on both sets of data and the human and statistical decisions compared. For phase images, circular SD was shown to discriminate better between normal and abnormal than experienced observers, but no single statistic discriminated as well as the human observer for amplitude images. (orig.)

  16. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Certain, D.A.; Brolio, R.; Salomon, G.C.; Carvalho, N.; Barbosa, Z.L.M.

    1972-01-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin 131 I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions [pt

  17. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Certain, D A; Brolio, R; Salomon, G C [Sao Paulo Univ. (Brazil). Faculdade de Saude Publica; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear; Barbosa, Z L.M. [Associacao dos Sanatorios Populares de Campos do Jordao, Brazil

    1972-10-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin /sup 131/I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions.

  18. X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography

    International Nuclear Information System (INIS)

    Honda, Chika; Ohara, Hiromu; Ishisaka, Akira; Shimada, Fumio

    2002-01-01

    Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage of Radiology (ACR) 156 mammography phantom. We obtained higher scores for phase imaging using high speed screen-film systems without any increase of X-ray dose than the score for contract imaging using a standard speed screen-film system. (author)

  19. Principle and preliminary results of the whole-body scintigraphic unit Omniview

    International Nuclear Information System (INIS)

    Methlin, G.; Jung, G.M.; Gerard, G.

    The Picker Company has recently launched a system adapted to its Dynacamera for the production of whole-body scintigraphs. For the last few months the radioisotopes service of the Strasbourg Anti-Cancer Centre has been in possession of such a system, intended mainly for systematic research on metastases, especially of the bone, and on the degree of extension of tumours. On the basis of the short experience so far acquired the report is limited to an outline of the working principle of this device, the presentation of preliminary documents and a few critical remarks summing up first impressions [fr

  20. Scintigraphic measurements of gastric emptying corrected for differences in tissue attenuation

    Energy Technology Data Exchange (ETDEWEB)

    Lauritzen, J.B.; Hoejgaard, L.; Uhrenholdt, A. (Copenhagen Univ. (Denmark). Hvidovre Hospital)

    1983-10-01

    In order to evaluate the importance of variations in tissue attenuation in scintigraphic measurements of gastric emptying, both in vivo and in vitro measurements of count rates from an encapsulated sup(99m)Tc dose were performed in different parts of the stomach. The obtained individual tissue correction factors were applied in the calculation of gastric emptying rates by gamma camera in healthy volunteers. The results showed that the anterior gamma camera scan without correction for differences in tissue attenuation underestimated the gastric emptying rate by 11% if the results were expressed as percentage meal emptied over 60 minutes.

  1. Characterisation of phase evolution under load by means of phase contrast imaging using synchrotron radiation

    International Nuclear Information System (INIS)

    Besseghini, S.; Stortiero, F.; Carcano, G.; Villa, E.; Mancini, L.; Tromba, G.; Zanini, F.; Montanari, F.; Airoldi, G.

    2003-01-01

    Phase contrast radiography (PCR) is a quite novel technique that is collecting increasing attention due to the possibility to obtain image information in presence of very small differences in the densities of the materials under analysis. Phase contrast imaging (PCI) has some specific advantage when compared with common microscopic techniques: (a) no special preparation of the sample is needed (b) the simultaneously investigated area is very large and (c) it allows the setting up of complex experimental apparatus. The results here presented are a good evidence of these three advantages. In this paper, we report on the application of phase contrast imaging in the study of the phase evolution during pseudoelastic transformation in the NiTiCu shape memory alloys (SMAs). The investigation was undertaken with the aim to identify some modification of the structure taking place at the end of the transformation plateau in the pseudoelastic behaviour of the alloy

  2. Two-phase summation imaging using transvenous DSA in subclavian steal syndrome

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1984-01-01

    A simple method is reported to obtain a two-phase summation image in subclavian steal syndrome using digital subtraction angiography (DSA) via selection of a mask during the early arterial phase and the contrast image during delayed retrograde filling of the ipsilateral vertebral artery and the postocclusive subclavian artery. The summation image results by employing replay of the stored image information. (orig.) [de

  3. Subclinical hyperthyroidism: current concepts and scintigraphic imaging.

    Science.gov (United States)

    Intenzo, Charles; Jabbour, Serge; Miller, Jeffrey L; Ahmed, Intekhab; Furlong, Kevin; Kushen, Medina; Kim, Sung M; Capuzzi, David M

    2011-09-01

    Subclinical hyperthyroidism is defined as normal serum free thyroxine and a free triiodothyronine level, with a thyroid-stimulating hormone level suppressed below the normal range and is usually undetectable. Although patients with this diagnosis have no or few signs and symptoms of overt thyrotoxicosis, there is sufficient evidence that it is associated with a relatively higher risk of supraventricular arrhythmias as well as the acceleration or the development of osteoporosis. Consequently, the approach to the patient with subclinical hyperthyroidism is controversial, that is, therapeutic intervention versus watchful waiting. Regardless, it is imperative for the referring physician to identify the causative thyroid disorder. This is optimally accomplished by a functional study, namely scintigraphy. Recognition of the scan findings of the various causes of subclinical hyperthyroidism enables the imaging specialist to help in diagnosing the underlying condition causing thyroid-stimulating hormone suppression thereby facilitating the workup and management of this thyroid disorder.

  4. Scintigraphic criteria for administration of therapeutic activities of 131I for ablation of residual thyroid tissue in patients with differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Dzhuzha, D.A.

    2003-01-01

    With the aim to determinate the optical scintigraphic criteria of radioablation of the small parts of residual thyroid tissue (RTT) after a thyroidectomy the results of postoperative monitoring of 29 women aged 23-60 with differentiated thyroid cancer, who did not get the radioiodine therapy, were analyzed. At the single postoperative scintigraphy with 131 I the optimal scintigraphic criteria for radioablation are the relative level of 131 I accumulation in RTT and the relative specific volume activity in RTT. At the values of these indices below 0.21% and 0.16%/sm 3 , respectively, only suppressive thyroid hormone therapy and standard monitoring are recommended

  5. Dynamic renal scintigraphic estimation of deceased donor kidneys in a rat model

    Directory of Open Access Journals (Sweden)

    Huseyin Aydin Mitil

    2017-01-01

    Full Text Available At present a large number of the renal transplantations are being performed from the deceased donors. The success of these transplantations depends on the viability of the deceased donor kidneys. The aim of this study was to investigate the reliability of scintigraphic estimation of function of deceased donor kidneys by comparing the histopathologic and scintigraphic findings. Ten rats were included in the study (2–3 months old, 250–300 g, all male. Control scintigraphy was performed to all the rats by injection of 37 MBq Tc-99m DTPA from the tail vein in a dynamic manner. Brain death of the rats was achieved by inflation of a Fogartys catheter in the cranial cavity. Immediately, after brain death confirmation, dynamic renal scintigraphy was performed with the same parameters of control scintigraphy. In the comparison of scintigraphies obtained in the before and just after brain death period, there was impairment of tubular functions, concentration and excretion functions in the postbrain death period. In the immediate postbrain death period, there was a significant elevation in the glomerular filtration rate and time to maximum concentration values. In the histopathological evaluation of the kidney samples in the postbrain death period, there were definitive findings of tubular impairment. Dynamic renal scintigraphy also demonstrated definite impairment of tubular system and tubular functions in the deceased donor kidneys. This could explain the reason of the increased frequency of acute tubular necrosis seen among deceased donor kidneys.

  6. Phase contrast imaging using a micro focus x-ray source

    Science.gov (United States)

    Zhou, Wei; Majidi, Keivan; Brankov, Jovan G.

    2014-09-01

    Phase contrast x-ray imaging, a new technique to increase the imaging contrast for the tissues with close attenuation coefficients, has been studied since mid 1990s. This technique reveals the possibility to show the clear details of the soft tissues and tumors in small scale resolution. A compact and low cost phase contrast imaging system using a conventional x-ray source is described in this paper. Using the conventional x-ray source is of great importance, because it provides the possibility to use the method in hospitals and clinical offices. Simple materials and components are used in the setup to keep the cost in a reasonable and affordable range.Tungsten Kα1 line with the photon energy 59.3 keV was used for imaging. Some of the system design details are discussed. The method that was used to stabilize the system is introduced. A chicken thigh bone tissue sample was used for imaging followed by the image quality, image acquisition time and the potential clinical application discussion. High energy x-ray beam can be used in phase contrast imaging. Therefore the radiation dose to the patients can be greatly decreased compared to the traditional x-ray radiography.

  7. Code-modulated interferometric imaging system using phased arrays

    Science.gov (United States)

    Chauhan, Vikas; Greene, Kevin; Floyd, Brian

    2016-05-01

    Millimeter-wave (mm-wave) imaging provides compelling capabilities for security screening, navigation, and bio- medical applications. Traditional scanned or focal-plane mm-wave imagers are bulky and costly. In contrast, phased-array hardware developed for mass-market wireless communications and automotive radar promise to be extremely low cost. In this work, we present techniques which can allow low-cost phased-array receivers to be reconfigured or re-purposed as interferometric imagers, removing the need for custom hardware and thereby reducing cost. Since traditional phased arrays power combine incoming signals prior to digitization, orthogonal code-modulation is applied to each incoming signal using phase shifters within each front-end and two-bit codes. These code-modulated signals can then be combined and processed coherently through a shared hardware path. Once digitized, visibility functions can be recovered through squaring and code-demultiplexing operations. Pro- vided that codes are selected such that the product of two orthogonal codes is a third unique and orthogonal code, it is possible to demultiplex complex visibility functions directly. As such, the proposed system modulates incoming signals but demodulates desired correlations. In this work, we present the operation of the system, a validation of its operation using behavioral models of a traditional phased array, and a benchmarking of the code-modulated interferometer against traditional interferometer and focal-plane arrays.

  8. Identification of various phases in HRTEM images of MgO-PSZ

    International Nuclear Information System (INIS)

    Liu, Z.; Spargo, A.E.C.

    2000-01-01

    Magnesia partially stabilized zirconia is one of the most commonly used engineering ceramics based on zirconia. A detailed discussion about how to identify the various phases in the high resolution transmission electron microscopy images of this material is presented. It shows that in some cases, the standard procedures of image simulation are inadequate to interpret these images. By including the effect of astigmatism in both experimental and simulated images, together with the digital Fourier transforms of the images, orthorhombic ZrO 2 in [001] orientation was identified. The δ-phase, which has a marked effect on the thermomechanical properties of MgO-PSZ, can most easily be identified by high resolution imaging in the [130] c zone which coincides with a low-index zone axis of the δ-phase

  9. Phase-Sensitive Coherence and the Classical-Quantum Boundary in Ghost Imaging

    Science.gov (United States)

    Erkmen, Baris I.; Hardy, Nicholas D.; Venkatraman, Dheera; Wong, Franco N. C.; Shapiro, Jeffrey H.

    2011-01-01

    The theory of partial coherence has a long and storied history in classical statistical optics. the vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-sate light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost imaging most closely mimicking those obtained in biphotons, and we derived the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.

  10. Time-resolved computed tomography of the liver: retrospective, multi-phase image reconstruction derived from volumetric perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Michael A.; Kartalis, Nikolaos; Aspelin, Peter; Albiin, Nils; Brismar, Torkel B. [Karolinska University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm (Sweden); Leidner, Bertil; Svensson, Anders [Karolinska University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm (Sweden); Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden)

    2014-01-15

    To assess feasibility and image quality (IQ) of a new post-processing algorithm for retrospective extraction of an optimised multi-phase CT (time-resolved CT) of the liver from volumetric perfusion imaging. Sixteen patients underwent clinically indicated perfusion CT using 4D spiral mode of dual-source 128-slice CT. Three image sets were reconstructed: motion-corrected and noise-reduced (MCNR) images derived from 4D raw data; maximum and average intensity projections (time MIP/AVG) of the arterial/portal/portal-venous phases and all phases (total MIP/ AVG) derived from retrospective fusion of dedicated MCNR split series. Two readers assessed the IQ, detection rate and evaluation time; one reader assessed image noise and lesion-to-liver contrast. Time-resolved CT was feasible in all patients. Each post-processing step yielded a significant reduction of image noise and evaluation time, maintaining lesion-to-liver contrast. Time MIPs/AVGs showed the highest overall IQ without relevant motion artefacts and best depiction of arterial and portal/portal-venous phases respectively. Time MIPs demonstrated a significantly higher detection rate for arterialised liver lesions than total MIPs/AVGs and the raw data series. Time-resolved CT allows data from volumetric perfusion imaging to be condensed into an optimised multi-phase liver CT, yielding a superior IQ and higher detection rate for arterialised liver lesions than the raw data series. (orig.)

  11. Multi-color phase imaging and sickle cell anemia (Conference Presentation)

    Science.gov (United States)

    Hosseini, Poorya; Zhou, Renjie; Yaqoob, Zahid; So, Peter T. C.

    2016-03-01

    Quantitative phase measurements at multiple wavelengths has created an opportunity for exploring new avenues in phase microscopy such as enhancing imaging-depth (1), measuring hemoglobin concentrations in erythrocytes (2), and more recently in tomographic mapping of the refractive index of live cells (3). To this end, quantitative phase imaging has been demonstrated both at few selected spectral points as well as with high spectral resolution (4,5). However, most of these developed techniques compromise imaging speed, field of view, or the spectral resolution to perform interferometric measurements at multiple colors. In the specific application of quantitative phase in studying blood diseases and red blood cells, current techniques lack the required sensitivity to quantify biological properties of interest at individual cell level. Recently, we have set out to develop a stable quantitative interferometric microscope allowing for measurements of such properties for red cells without compromising field of view or speed of the measurements. The feasibility of the approach will be initially demonstrated in measuring dispersion curves of known solutions, followed by measuring biological properties of red cells in sickle cell anemia. References: 1. Mann CJ, Bingham PR, Paquit VC, Tobin KW. Quantitative phase imaging by three-wavelength digital holography. Opt Express. 2008;16(13):9753-64. 2. Park Y, Yamauchi T, Choi W, Dasari R, Feld MS. Spectroscopic phase microscopy for quantifying hemoglobin concentrations in intact red blood cells. Opt Lett. 2009;34(23):3668-70. 3. Hosseini P, Sung Y, Choi Y, Lue N, Yaqoob Z, So P. Scanning color optical tomography (SCOT). Opt Express. 2015;23(15):19752-62. 4. Jung J-H, Jang J, Park Y. Spectro-refractometry of individual microscopic objects using swept-source quantitative phase imaging. Anal Chem. 2013;85(21):10519-25. 5. Rinehart M, Zhu Y, Wax A. Quantitative phase spectroscopy. Biomed Opt Express. 2012;3(5):958-65.

  12. Combined mixed approach algorithm for in-line phase-contrast x-ray imaging

    International Nuclear Information System (INIS)

    De Caro, Liberato; Scattarella, Francesco; Giannini, Cinzia; Tangaro, Sabina; Rigon, Luigi; Longo, Renata; Bellotti, Roberto

    2010-01-01

    Purpose: In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an imaging modality thought to enhance the total contrast of the images through the phase shift introduced by the object (human body part); PRI is a mathematical technique to extract the quantitative phase-shift map from PCI. A new phase-retrieval algorithm for the in-line phase-contrast x-ray imaging is here proposed. Methods: The proposed algorithm is based on a mixed transfer-function and transport-of-intensity approach (MA) and it requires, at most, an initial approximate estimate of the average phase shift introduced by the object as prior knowledge. The accuracy in the initial estimate determines the convergence speed of the algorithm. The proposed algorithm retrieves both the object phase and its complex conjugate in a combined MA (CMA). Results: Although slightly less computationally effective with respect to other mixed-approach algorithms, as two phases have to be retrieved, the results obtained by the CMA on simulated data have shown that the obtained reconstructed phase maps are characterized by particularly low normalized mean square errors. The authors have also tested the CMA on noisy experimental phase-contrast data obtained by a suitable weakly absorbing sample consisting of a grid of submillimetric nylon fibers as well as on a strongly absorbing object made of a 0.03 mm thick lead x-ray resolution star pattern. The CMA has shown a good efficiency in recovering phase information, also in presence of noisy data, characterized by peak-to-peak signal-to-noise ratios down to a few dBs, showing the possibility to enhance with phase radiography the signal-to-noise ratio for features in the submillimetric scale with respect to the attenuation

  13. In vivo comparative study of hydroxyapatite labeled with different radioisotopes: evaluation of the scintigraphic images

    Energy Technology Data Exchange (ETDEWEB)

    Couto, Renata Martinussi; Barboza, Marycel Figols de; Souza, Adriano Aparecido de; Muramoto, Emiko; Mengatti, Jair; Araujo, Elaine Bortoleti de, E-mail: rmcouto@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia

    2008-07-01

    Rheumatoid arthritis (RA) is a chronic inflammatory disorder of joints that is characterized by the inflammation and proliferation of synovial tissues. Approximately 3% of the adult population in the world is affected by this disease which causes pain, joint immobility and disability. Adyo synovectomy (RSV) is a radiotherapeutic modality where a b--emitting radionuclide is administered locally by intra-articular injection on the form of a colloid or radiolabeled particulate. RSV is a well-accepted therapeutic procedure in inflammatory joint diseases and has been successfully employed for more than 50 years as a viable alternative to surgical and chemical synovectomy in the treatment of RA and other inflammatory arthropathies. There are several radionuclides available for this purpose such as {sup 177}Lu, {sup 90}Y, {sup 153}Sm, {sup 165}Dy, and {sup 166}Ho. Hydroxyapatite (HA) is one of the preferred particulates for this application because it is the major chemical constituent of skeletal bone and it is converted into Ca and PO4 ions in the body. In addition HA is completely eliminated over a period of six weeks. The aim of this work is to compare the in vivo stability of hydroxyapatite labeled with {sup 177}Lu, {sup 90}Y and {sup 153}Sm in order to determine the influence of the radionuclide on biological pattern. In biological studies, 100mL of labeled HAs suspended in normal saline were injected into normal knee joints of Wistar rats and the retention of the activity into the synovium was determined. Labeled particles were also injected by intravenous and intramuscular administration, to verify the biodistribution in the case of an eventual leakage of the products from the joint. Sequential scintigraphic images were acquired from 1 hour to 7 days p.i. after anesthetizing the animals with ketamine. Hydroxyapatite was radiolabeled by all radionuclides with high yield. {sup 177}Lu-HA, {sup 90}Y-HA and {sup 153}Sm-HA were retained in the joint for 7 days, showing

  14. Noise propagation in x-ray phase-contrast imaging and computed tomography

    International Nuclear Information System (INIS)

    Nesterets, Yakov I; Gureyev, Timur E

    2014-01-01

    Three phase-retrieval algorithms, based on the transport-of-intensity equation and on the contrast transfer function for propagation-based imaging, and on the linearized geometrical optics approximation for analyser-based imaging, are investigated. The algorithms are compared in terms of their effect on propagation of noise from projection images to the corresponding phase-retrieved images and further to the computed tomography (CT) images/slices of a monomorphous object reconstructed using filtered backprojection algorithm. The comparison is carried out in terms of an integral noise characteristic, the variance, as well as in terms of a simple figure-of-merit, i.e. signal-to-noise ratio per unit dose. A gain factor is introduced that quantitatively characterizes the effect of phase retrieval on the variance of noise in the reconstructed projection images and in the axial slices of the object. Simple analytical expressions are derived for the gain factor and the signal-to-noise ratio, which indicate that the application of phase-retrieval algorithms can increase these parameters by up to two orders of magnitude compared to raw projection images and conventional CT, thus allowing significant improvement in the image quality and/or reduction of the x-ray dose delivered to the patient. (paper)

  15. A common-path phase-shift interferometry surface plasmon imaging system

    Science.gov (United States)

    Su, Y.-T.; Chen, Shean-Jen; Yeh, T.-L.

    2005-03-01

    A biosensing imaging system is proposed based on the integration of surface plasmon resonance (SPR) and common-path phase-shift interferometry (PSI) techniques to measure the two-dimensional spatial phase variation caused by biomolecular interactions upon a sensing chip. The SPR phase imaging system can offer high resolution and high-throughout screening capabilities to analyze microarray biomolecular interaction without the need for additional labeling. With the long-term stability advantage of the common-path PSI technique even with external disturbances such as mechanical vibration, buffer flow noise, and laser unstable issue, the system can match the demand of real-time kinetic study for biomolecular interaction analysis (BIA). The SPR-PSI imaging system has achieved a detection limit of 2×10-7 refraction index change, a long-term phase stability of 2.5x10-4π rms over four hours, and a spatial phase resolution of 10-3 π with a lateral resolution of 100μm.

  16. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  17. Thermosetting gels with modulated gelation temperature for ophthalmic use: the rheological and gamma scintigraphic studies.

    Science.gov (United States)

    Wei, Gang; Xu, Hui; Ding, Ping Tian; Li, San Ming; Zheng, Jun Min

    2002-09-18

    For ophthalmic drug delivery, Pluronic F127 solutions have a phase transition temperature too low for them to be instilled into the eye at room temperature. Refrigerator storage is usually required to make administration easier, whereas the potential irritation of cold to the sensitive ocular tissues may result in poor topical bioavailability. The purpose of this study is to develop a thermosetting gel with a suitable phase transition temperature by combining Pluronic analogs and to examine the influence of incorporating mucoadhesive polysaccharide, sodium hyaluronate (HA-Na), on the ocular retention of the gel. Dynamic rheological method and single photon emission computing tomography (SPECT) technique were used to ex/in vivo evaluate the thermosetting gels, respectively. An optimized formulation containing 21% F127 and 10% F68 increased the phase transition temperature by 9 degrees C as evaluated by elasticity modulus compared to that of individual 21% F127 solution. Rheological behaviors of the Pluronic solutions showed that the combined Pluronic formulation was free flowing liquid below 25 degrees C and converted to a firm gel under the physiological condition. Furthermore, this formulation possessed the highest viscosity both before and after tear dilution at 35 degrees C. Gamma scintigraphic data demonstrated that the clearance of the thermosetting gel labeled with 99mTc-DTPA was significantly delayed with respect to the phosphate buffered solution, and at least a threefold increase of the corneal residence time was achieved. However, no further improvement in the ocular retention was observed when adding HA-Na into the thermosetting gel due to the substantially decreased gel strength. Copyright 2002 Elsevier Science B.V.

  18. Grating-based x-ray differential phase contrast imaging with twin peaks in phase-stepping curves—phase retrieval and dewrapping

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yi; Xie, Huiqiao; Tang, Xiangyang, E-mail: xiangyang.tang@emory.edu [Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C-5018, Atlanta, Georgia 30322 (United States); Cai, Weixing [Department of Radiation Oncology, Brigham and Women’s Hospital Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115 (United States); Mao, Hui [Laboratory of Functional and Molecular Imaging and Nanomedicine, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road NE, Atlanta, Georgia 30329 (United States)

    2016-06-15

    Purpose: X-ray differential phase contrast CT implemented with Talbot interferometry employs phase-stepping to extract information of x-ray attenuation, phase shift, and small-angle scattering. Since inaccuracy may exist in the absorption grating G{sub 2} due to an imperfect fabrication, the effective period of G{sub 2} can be as large as twice the nominal period, leading to a phenomenon of twin peaks that differ remarkably in their heights. In this work, the authors investigate how to retrieve and dewrap the phase signal from the phase-stepping curve (PSC) with the feature of twin peaks for x-ray phase contrast imaging. Methods: Based on the paraxial Fresnel–Kirchhoff theory, the analytical formulae to characterize the phenomenon of twin peaks in the PSC are derived. Then an approach to dewrap the retrieved phase signal by jointly using the phases of the first- and second-order Fourier components is proposed. Through an experimental investigation using a prototype x-ray phase contrast imaging system implemented with Talbot interferometry, the authors evaluate and verify the derived analytic formulae and the proposed approach for phase retrieval and dewrapping. Results: According to theoretical analysis, the twin-peak phenomenon in PSC is a consequence of combined effects, including the inaccuracy in absorption grating G{sub 2}, mismatch between phase grating and x-ray source spectrum, and finite size of x-ray tube’s focal spot. The proposed approach is experimentally evaluated by scanning a phantom consisting of organic materials and a lab mouse. The preliminary data show that compared to scanning G{sub 2} over only one single nominal period and correcting the measured phase signal with an intuitive phase dewrapping method that is being used in the field, stepping G{sub 2} over twice its nominal period and dewrapping the measured phase signal with the proposed approach can significantly improve the quality of x-ray differential phase contrast imaging in both

  19. Clinical evaluation of left ventricular wall thickness by combined technique with gated planer /sup 201/Tl image and gated cardiac pool image

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Kenji; Katsuragawa, Shigehiko; Takahashi, Tsuneo; Matsushita, Kazuo; Kawamura, Akiyoshi

    1983-11-01

    To evaluate the left ventricular (LV) wall thickness, a combined technique with gated planer 201-thallium image and gated cardiac pool image was applied to 6 patients with hypertrophic cardiomyopathy (HCM) and 4 patients with secondary hypertrophy due to hypertension (HHD) proven by electrocardiography and ultrasonic-echocardiography. Scintigraphic pattern of hypertrophy on reconstructed planer /sup 201/Tl image showed diffuse or asymmetrical apical hypertrophy in HHD, asymmetrical septal hypertrophy in HCM. It was very interesting that abnormal perfusion was shown in /sup 201/Tl image, despite symmetrical hypertrophy in echocardiography. This techniques provided useful information for evaluating the LV wall thickness and cardiac performance.

  20. Blind phase retrieval for aberrated linear shift-invariant imaging systems

    International Nuclear Information System (INIS)

    Yu, Rotha P; Paganin, David M

    2010-01-01

    We develop a means to reconstruct an input complex coherent scalar wavefield, given a through focal series (TFS) of three intensity images output from a two-dimensional (2D) linear shift-invariant optical imaging system with unknown aberrations. This blind phase retrieval technique unites two methods, namely (i) TFS phase retrieval and (ii) iterative blind deconvolution. The efficacy of our blind phase retrieval procedure has been demonstrated using simulated data, for a variety of Poisson noise levels.

  1. Grating-based X-ray phase contrast for biomedical imaging applications

    International Nuclear Information System (INIS)

    Pfeiffer, Franz; Willner, Marian; Chabior, Michael; Herzen, Julia; Helmholtz-Zentrum Geesthacht, Geesthacht; Auweter, Sigrid; Reiser, Maximilian; Bamberg, Fabian

    2013-01-01

    In this review article we describe the development of grating-based X-ray phase-contrast imaging, with particular emphasis on potential biomedical applications of the technology. We review the basics of image formation in grating-based phase-contrast and dark-field radiography and present some exemplary multimodal radiography results obtained with laboratory X-ray sources. Furthermore, we discuss the theoretical concepts to extend grating-based multimodal radiography to quantitative transmission, phase-contrast, and dark-field scattering computed tomography. (orig.)

  2. Quantitative evaluation of a single-distance phase-retrieval method applied on in-line phase-contrast images of a mouse lung

    International Nuclear Information System (INIS)

    Mohammadi, Sara; Larsson, Emanuel; Alves, Frauke; Dal Monego, Simeone; Biffi, Stefania; Garrovo, Chiara; Lorenzon, Andrea; Tromba, Giuliana; Dullin, Christian

    2014-01-01

    Quantitative analysis concerning the application of a single-distance phase-retrieval algorithm on in-line phase-contrast images of a mouse lung at different sample-to-detector distances is presented. Propagation-based X-ray phase-contrast computed tomography (PBI) has already proven its potential in a great variety of soft-tissue-related applications including lung imaging. However, the strong edge enhancement, caused by the phase effects, often hampers image segmentation and therefore the quantitative analysis of data sets. Here, the benefits of applying single-distance phase retrieval prior to the three-dimensional reconstruction (PhR) are discussed and quantified compared with three-dimensional reconstructions of conventional PBI data sets in terms of contrast-to-noise ratio (CNR) and preservation of image features. The PhR data sets show more than a tenfold higher CNR and only minor blurring of the edges when compared with PBI in a predominately absorption-based set-up. Accordingly, phase retrieval increases the sensitivity and provides more functionality in computed tomography imaging

  3. Phase image characterization of ventricular contraction in left anterior hemiblock

    International Nuclear Information System (INIS)

    Ono, Akifumi; Mizuno, Haruyoshi; Tahara, Yorio; Ishikawa, Kyozo

    1991-01-01

    We investigated whether or not left anterior hemiblock is present in patients with left axis deviation using first-harmonic Fourier analysis of gated blood-pool images. Gated blood-pool images were taken in 50 patients without contraction abnormality. They included 14 normal subjects, 8 patients with right bundle branch block (RBBB), 20 with left axis deviation (LAD) and 8 with both RBBB and LAD (RBBB+LAD). ECG gated blood-pool scans were acquired in the anterior and 'best septal' left anterior oblique projections. First, the phase images were displayed cinematically as a continuous-loop movie. Next, for quantitative analysis of the phase image, the whole left ventricular and left ventricular high lateral regions of interest were drawn. The 'regional phase shift' (RPS) was then defined as {RPS=A-a} where 'A' is the mean value of the whole left ventricular phase angles and 'a' is that of phase angles in the high lateral region. The left ventricular phase changes and the RPSs in the RBBB and LAD groups were similar to those in the normal group. In the RBBB+LAD group, the latest phase changes occurred in the high anterolateral region. The RPSs of this group were significantly lower than those in the other 3 groups (p<0.01). These data suggest that left anterior hemiblock might coexist with RBBB in patients with RBBB+LAD, whereas left anterior hemiblock might not exist in the majority of patients with LAD alone. (author)

  4. Parallel scintigraphic and echographic studies in patients with miscellaneous andrologic diseases

    International Nuclear Information System (INIS)

    Sultanov, S.; Stanchev, P.; Tsvetkov, D.

    1989-01-01

    The diagnostic possibilities of scintigraphic and echographic methods are compared for diagnostics of varicocele, cryptorchidism, orchiepididymitis, atrophy of the testis, post orchidopexy state, tumors, torsion and hypogonadism. A nonselected group of 33 patients is studied. In 24 patients was coincidence in the results from gamma camera scintigraphy and echography, in 7 - lack of coincidence and in 3 - partial coincidence. It is concludied that the two methods are quick, exact and noninvasive. Gamma-camera scintigraphy is especially suitable for torsion, where the diagnosis is infallible, for cryptorchidism, varicocele and for tumors, where the necrotic zones in the testis are very precisely visualized. 3 figs., 4 refs

  5. Interferometric Imaging Directly with Closure Phases and Closure Amplitudes

    Science.gov (United States)

    Chael, Andrew A.; Johnson, Michael D.; Bouman, Katherine L.; Blackburn, Lindy L.; Akiyama, Kazunori; Narayan, Ramesh

    2018-04-01

    Interferometric imaging now achieves angular resolutions as fine as ∼10 μas, probing scales that are inaccessible to single telescopes. Traditional synthesis imaging methods require calibrated visibilities; however, interferometric calibration is challenging, especially at high frequencies. Nevertheless, most studies present only a single image of their data after a process of “self-calibration,” an iterative procedure where the initial image and calibration assumptions can significantly influence the final image. We present a method for efficient interferometric imaging directly using only closure amplitudes and closure phases, which are immune to station-based calibration errors. Closure-only imaging provides results that are as noncommittal as possible and allows for reconstructing an image independently from separate amplitude and phase self-calibration. While closure-only imaging eliminates some image information (e.g., the total image flux density and the image centroid), this information can be recovered through a small number of additional constraints. We demonstrate that closure-only imaging can produce high-fidelity results, even for sparse arrays such as the Event Horizon Telescope, and that the resulting images are independent of the level of systematic amplitude error. We apply closure imaging to VLBA and ALMA data and show that it is capable of matching or exceeding the performance of traditional self-calibration and CLEAN for these data sets.

  6. Present and future of the hybrid imaging method SPECT/CT

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2013-01-01

    Full text: Introduction: Based on the data in the literature and on our 4 year clinical experience applied for the first time in our country hybrid imaging - single photon emission tomography combined with computed tomography (SPECT / CT) it is clear that to obtain comprehensive information about the function and structure of the studied organ; the time for the diagnosis and thus the start of adequate treatment become shorter. The resulting scintigraphic image is with better quality due to CT correction of ‘diffusion’ gamma radiation, which leads to greater diagnostic accuracy. What you will learn: complex imaging method is used mainly in the field of endocrinology, cardiology, oncology, orthopedics, pulmology, neurology, and neurosurgery. It can be prove a given disease by visualization and localization of the organ lesions and determine the stage of the tumor process, to plan the type of subsequent treatment, to follow the effects of the therapy, and to predict the effect of an interventional or miniinvasive surgical procedure. Discussion: The result of the application of the hybrid imaging method is a change in the interpretation of more than half of the studied patients and in the treatment in more than a quarter of them. Conclusion: The clinical indications for SPECT/CT, and evidence of increased diagnostic accuracy compared with self- administered scintigraphic or CT methods are continuous expanded

  7. Application of Fourier-wavelet regularized deconvolution for improving image quality of free space propagation x-ray phase contrast imaging.

    Science.gov (United States)

    Zhou, Zhongxing; Gao, Feng; Zhao, Huijuan; Zhang, Lixin

    2012-11-21

    New x-ray phase contrast imaging techniques without using synchrotron radiation confront a common problem from the negative effects of finite source size and limited spatial resolution. These negative effects swamp the fine phase contrast fringes and make them almost undetectable. In order to alleviate this problem, deconvolution procedures should be applied to the blurred x-ray phase contrast images. In this study, three different deconvolution techniques, including Wiener filtering, Tikhonov regularization and Fourier-wavelet regularized deconvolution (ForWaRD), were applied to the simulated and experimental free space propagation x-ray phase contrast images of simple geometric phantoms. These algorithms were evaluated in terms of phase contrast improvement and signal-to-noise ratio. The results demonstrate that the ForWaRD algorithm is most appropriate for phase contrast image restoration among above-mentioned methods; it can effectively restore the lost information of phase contrast fringes while reduce the amplified noise during Fourier regularization.

  8. Usefulness of tomographic phase image in ventricular conduction abnormalities

    International Nuclear Information System (INIS)

    Sakurai, Mitsuru; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    In order to evaluate three-dimensional phase changes in ventricular conduction abnormalities, tomographic phase images were constructed in 7 normal subjects, 12 patients with ventricular pacing, 21 patients with bundle branch block and 12 patients with Wolff-Parkinson-White syndrome. Eight to 12 slices of the short-axis ventricular tomographic phase image (TPI) were derived using a 7-pinhole collimator, and compared with planar phase images (PPIs) in left anterior oblique (LAO) and right anterior oblique (RAO) projections. TPIs were excellent for observing biventricular phase changes in the long-axis direction. In 6 cases of complete right bundle branch block with left axis deviation (beyond -30 0 ), the phase delay in the left ventricular anterior wall was recognized in 5 cases by TPI, although it was difficult to be detected by PPIs. The site of the pacing electrode was identified by TPI in 11 out of 12 cases, compared to 8 cases by PPIs in LAO and RAO projections. The site of the accessory pathway in Wolff-Parkinson-White syndrome was detected in the basal slice of TPIs in 10 out of 12 cases, compared to 8 cases by PPI in the LAO projection. Therefore, it is obvious that TPIs offer more valid information than PPIs. In conclusion, TPI is useful for investigation of ventricular conduction abnormalities. (author)

  9. Techniques for combining isotopic images obtained at different energies

    International Nuclear Information System (INIS)

    Soussaline, F.; Di Paola, R.; Bazin, J.P.

    1976-01-01

    The technique described should be considered as a first step towards the classification of scintigraphic data where the energy is included. As in all such studies the interpretation of the resulting images is not necessarily at first evident, and certain experience needs to be established. This applies in particular to the images obtained with the higher factors. It is possible that the use of this technique may resolve, without requiring a priori information, the problem previously encountered using the other 'subtraction' type techniques [fr

  10. A simple scintigraphic method for continuous monitoring of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Lipp, R.W.; Hammer, H.F.; Schnedl, W.; Dobnig, H.; Passath, A.; Leb, G.; Krejs, G.J. (Graz Univ. (Austria). Div. of Nuclear Medicine and Endocrinology)

    1993-03-01

    A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as acitivty retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients. (orig.).

  11. Multimodality image analysis work station

    International Nuclear Information System (INIS)

    Ratib, O.; Huang, H.K.

    1989-01-01

    The goal of this project is to design and implement a PACS (picture archiving and communication system) workstation for quantitative analysis of multimodality images. The Macintosh II personal computer was selected for its friendly user interface, its popularity among the academic and medical community, and its low cost. The Macintosh operates as a stand alone workstation where images are imported from a central PACS server through a standard Ethernet network and saved on a local magnetic or optical disk. A video digitizer board allows for direct acquisition of images from sonograms or from digitized cine angiograms. The authors have focused their project on the exploration of new means of communicating quantitative data and information through the use of an interactive and symbolic user interface. The software developed includes a variety of image analysis, algorithms for digitized angiograms, sonograms, scintigraphic images, MR images, and CT scans

  12. Direct imaging of phase objects enables conventional deconvolution in bright field light microscopy.

    Directory of Open Access Journals (Sweden)

    Carmen Noemí Hernández Candia

    Full Text Available In transmitted optical microscopy, absorption structure and phase structure of the specimen determine the three-dimensional intensity distribution of the image. The elementary impulse responses of the bright field microscope therefore consist of separate absorptive and phase components, precluding general application of linear, conventional deconvolution processing methods to improve image contrast and resolution. However, conventional deconvolution can be applied in the case of pure phase (or pure absorptive objects if the corresponding phase (or absorptive impulse responses of the microscope are known. In this work, we present direct measurements of the phase point- and line-spread functions of a high-aperture microscope operating in transmitted bright field. Polystyrene nanoparticles and microtubules (biological polymer filaments serve as the pure phase point and line objects, respectively, that are imaged with high contrast and low noise using standard microscopy plus digital image processing. Our experimental results agree with a proposed model for the response functions, and confirm previous theoretical predictions. Finally, we use the measured phase point-spread function to apply conventional deconvolution on the bright field images of living, unstained bacteria, resulting in improved definition of cell boundaries and sub-cellular features. These developments demonstrate practical application of standard restoration methods to improve imaging of phase objects such as cells in transmitted light microscopy.

  13. Prospects and challenges of quantitative phase imaging in tumor cell biology

    Science.gov (United States)

    Kemper, Björn; Götte, Martin; Greve, Burkhard; Ketelhut, Steffi

    2016-03-01

    Quantitative phase imaging (QPI) techniques provide high resolution label-free quantitative live cell imaging. Here, prospects and challenges of QPI in tumor cell biology are presented, using the example of digital holographic microscopy (DHM). It is shown that the evaluation of quantitative DHM phase images allows the retrieval of different parameter sets for quantification of cellular motion changes in migration and motility assays that are caused by genetic modifications. Furthermore, we demonstrate simultaneously label-free imaging of cell growth and morphology properties.

  14. Effect of masking phase-only holograms on the quality of reconstructed images.

    Science.gov (United States)

    Deng, Yuanbo; Chu, Daping

    2016-04-20

    A phase-only hologram modulates the phase of the incident light and diffracts it efficiently with low energy loss because of the minimum absorption. Much research attention has been focused on how to generate phase-only holograms, and little work has been done to understand the effect and limitation of their partial implementation, possibly due to physical defects and constraints, in particular as in the practical situations where a phase-only hologram is confined or needs to be sliced or tiled. The present study simulates the effect of masking phase-only holograms on the quality of reconstructed images in three different scenarios with different filling factors, filling positions, and illumination intensity profiles. Quantitative analysis confirms that the width of the image point spread function becomes wider and the image quality decreases, as expected, when the filling factor decreases, and the image quality remains the same for different filling positions as well. The width of the image point spread function as derived from different filling factors shows a consistent behavior to that as measured directly from the reconstructed image, especially as the filling factor becomes small. Finally, mask profiles of different shapes and intensity distributions are shown to have more complicated effects on the image point spread function, which in turn affects the quality and textures of the reconstructed image.

  15. Scintigraphic hepatobiliary function studies in newborn infants to diagnose biliary hypoplasia or atresia

    International Nuclear Information System (INIS)

    Askari-Sabi, Z.

    1987-01-01

    The results obtained from scintigraphic hepatobiliary function studies, intraoperative cholangiography and histological examinations in a total of 17 infants suspected of having biliary atresia were compared and analysed with reference to the clinical signs and symptoms observed. In most cases, the individual diagnostic procedures led to consistent findings, even though there were some variations in the clinical picture. Patient outcome is largely determined by the site of atresia, due to which fact surgical correction should be carried out as soon as possible, in any case before the 8th week post partum. (TRV) [de

  16. Model-based magnetization retrieval from holographic phase images

    Energy Technology Data Exchange (ETDEWEB)

    Röder, Falk, E-mail: f.roeder@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institut für Ionenstrahlphysik und Materialforschung, Bautzner Landstr. 400, D-01328 Dresden (Germany); Triebenberg Labor, Institut für Strukturphysik, Technische Universität Dresden, D-01062 Dresden (Germany); Vogel, Karin [Triebenberg Labor, Institut für Strukturphysik, Technische Universität Dresden, D-01062 Dresden (Germany); Wolf, Daniel [Helmholtz-Zentrum Dresden-Rossendorf, Institut für Ionenstrahlphysik und Materialforschung, Bautzner Landstr. 400, D-01328 Dresden (Germany); Triebenberg Labor, Institut für Strukturphysik, Technische Universität Dresden, D-01062 Dresden (Germany); Hellwig, Olav [Helmholtz-Zentrum Dresden-Rossendorf, Institut für Ionenstrahlphysik und Materialforschung, Bautzner Landstr. 400, D-01328 Dresden (Germany); AG Magnetische Funktionsmaterialien, Institut für Physik, Technische Universität Chemnitz, D-09126 Chemnitz (Germany); HGST, A Western Digital Company, 3403 Yerba Buena Rd., San Jose, CA 95135 (United States); Wee, Sung Hun [HGST, A Western Digital Company, 3403 Yerba Buena Rd., San Jose, CA 95135 (United States); Wicht, Sebastian; Rellinghaus, Bernd [IFW Dresden, Institute for Metallic Materials, P.O. Box 270116, D-01171 Dresden (Germany)

    2017-05-15

    The phase shift of the electron wave is a useful measure for the projected magnetic flux density of magnetic objects at the nanometer scale. More important for materials science, however, is the knowledge about the magnetization in a magnetic nano-structure. As demonstrated here, a dominating presence of stray fields prohibits a direct interpretation of the phase in terms of magnetization modulus and direction. We therefore present a model-based approach for retrieving the magnetization by considering the projected shape of the nano-structure and assuming a homogeneous magnetization therein. We apply this method to FePt nano-islands epitaxially grown on a SrTiO{sub 3} substrate, which indicates an inclination of their magnetization direction relative to the structural easy magnetic [001] axis. By means of this real-world example, we discuss prospects and limits of this approach. - Highlights: • Retrieval of the magnetization from holographic phase images. • Magnetostatic model constructed for a magnetic nano-structure. • Decomposition into homogeneously magnetized components. • Discretization of a each component by elementary cuboids. • Analytic solution for the phase of a magnetized cuboid considered. • Fitting a set of magnetization vectors to experimental phase images.

  17. Fast X-ray imaging of two-phase flows: Application to cavitating flows

    International Nuclear Information System (INIS)

    Khlifa, Ilyass

    2014-01-01

    A promising method based on fast X-ray imaging has been developed to investigate the dynamics and the structure of complex two-phase flows. It has been applied in this work on cavitating flows created inside a Venturi-type test section and helped therefore to better understand flows inside cavitation pockets. Seeding particles were injected into the flow to trace the liquid phase. Thanks to the characteristics of the beam provided by the APS synchrotron (Advance Photon Source, USA), high definition X-ray images of the flow containing simultaneously information for both liquid and vapour were obtained. Velocity fields of both phases were thus calculated using image cross-correlation algorithms. Local volume fractions of vapour have also been obtained using local intensities of the images. Beforehand however, image processing is required to separate phases for velocity measurements. Validation methods of all applied treatments were developed, they allowed to characterise the measurement accuracy. This experimental technique helped us to have more insight into the dynamic of cavitating flows and especially demonstrates the presence of significant slip velocities between phases. (author)

  18. Improvements in image quality with pseudo-parallel imaging in the phase-scrambling fourier transform technique

    International Nuclear Information System (INIS)

    Ito, Satoshi; Kawawa, Yasuhiro; Yamada, Yoshifumi

    2010-01-01

    The signal obtained in the phase-scrambling Fourier transform (PSFT) imaging technique can be transformed to the signal described by the Fresnel transform of the objects, in which the amplitude of the PSFT presents some kind of blurred image of the objects. Therefore, the signal can be considered to exist in the object domain as well as the Fourier domain of the object. This notable feature makes it possible to assign weights to the reconstructed images by applying a weighting function to the PSFT signal after data acquisition, and as a result, pseudo-parallel image reconstruction using these aliased image data with different weights on the images is feasible. In this study, the improvements in image quality with such pseudo-parallel imaging were examined and demonstrated. The weighting function of the PSFT signal that provides a given weight on the image is estimated using the obtained image data and is iteratively updated after sensitivity encoding (SENSE)-based image reconstruction. Simulation studies showed that reconstruction errors were dramatically reduced and that the spatial resolution was also improved in almost all image spaces. The proposed method was applied to signals synthesized from MR image data with phase variations to verify its effectiveness. It was found that the image quality was improved and that images almost entirely free of aliasing artifacts could be obtained. (author)

  19. Approximated transport-of-intensity equation for coded-aperture x-ray phase-contrast imaging.

    Science.gov (United States)

    Das, Mini; Liang, Zhihua

    2014-09-15

    Transport-of-intensity equations (TIEs) allow better understanding of image formation and assist in simplifying the "phase problem" associated with phase-sensitive x-ray measurements. In this Letter, we present for the first time to our knowledge a simplified form of TIE that models x-ray differential phase-contrast (DPC) imaging with coded-aperture (CA) geometry. The validity of our approximation is demonstrated through comparison with an exact TIE in numerical simulations. The relative contributions of absorption, phase, and differential phase to the acquired phase-sensitive intensity images are made readily apparent with the approximate TIE, which may prove useful for solving the inverse phase-retrieval problem associated with these CA geometry based DPC.

  20. Results of phase III clinical trial of {sup 99m}Tc-labelled recombinant tissue plasminogen activator in the detection of deep venous thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Butler, S.P.; Boyd, S.J.; Parkes, S.L.; Quinn, R.J. [St George Hospital, Kogarah, NSW (Australia)

    1998-03-01

    Full text: The purpose of this study was to compare the accuracy of this new technique against the accepted ``gold standard`` of contrast venography in 79 patients suspected of DVT. A kit formulation has been devised in which {sup 99}mTc is labelled to rt- PA where the plasminogen binding site has been permanently inhibited but the fibrin binding site remained active. Kit preparation takes five minutes. Scintigraphic imaging is performed at four hours post-injection (10 min/scan for thighs and calves). The results of scintigraphic imaging were then compared to those of contrast venography. Mean thrombus age was 5.4 days. 58% patients were receiving intravenous heparin. Mean time interval between contrast venography and scanning was 20 hours. For the purpose of analysis, the leg was divided into proximal and distal segments for both the scintigraphic study and the contrast venography. Of the 14 thrombosed proximal segments, 13 had positive scans; in the 53 non-thrombosed proximal segments, 49 had negative scans. Thus in proximal vein thrombosis, scanning had a sensitivity of 93% and a specificity of 92%. Of the 36 thrombosed calf vein segments, 31 had positive scans; in the 30 non-thrombosed calf segments, 28 had negative scans. Thus in calf vein thrombosis, scanning has a sensitivity of 86% and a specificity of 93%. Scintigraphic scanning with this new radiopharmaceutical permits accurate detection of thrombus in both proximal and calf veins. The technique detects both fresh and aged thrombi and is unaffected by heparin administration. Further work in different patient groups will need to be performed to define its clinical usefulness.

  1. Noninterferometric phase imaging of a neutral atomic beam

    International Nuclear Information System (INIS)

    Fox, P.J.; Mackin, T.R.; Turner, L.D.; Colton, I.; Nugent, K.A.; Scholten, R.E.

    2002-01-01

    We demonstrate quantitative phase imaging of a neutral atomic beam by using a noninterferometric technique. A collimated thermal atomic beam is phase shifted by an off-resonant traveling laser beam with both a Gaussian and a TEM 01 profile and with both red and blue detuning of as much as 50 GHz. Phase variations of more than 1000 rad were recovered from velocity-selective measurements of the propagation of the atomic beam and were found to be in quantitative agreement with theoretical predictions based on independently measured phase object intensity profiles and detunings

  2. The hypofunctioning thyroid nodule: Radiography, computed tomography (CT) and magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Dorn, R.; Wagner-Manslau, C.

    1992-01-01

    The hyperfunctioning thyroid nodule is a scintigraphic diagnosis by definition. Its dignity is assessed by fine needle aspiration biopsy. Radiographic methods and magnetic resonance imaging (MRI) are no primary tools in diagnosis of the hypofunctioning thyroid nodule but may reveal additional information, especially in cases of retrosternal goiter and thyroid malignomas. (orig.) [de

  3. Phase-Image Encryption Based on 3D-Lorenz Chaotic System and Double Random Phase Encoding

    Science.gov (United States)

    Sharma, Neha; Saini, Indu; Yadav, AK; Singh, Phool

    2017-12-01

    In this paper, an encryption scheme for phase-images based on 3D-Lorenz chaotic system in Fourier domain under the 4f optical system is presented. The encryption scheme uses a random amplitude mask in the spatial domain and a random phase mask in the frequency domain. Its inputs are phase-images, which are relatively more secure as compared to the intensity images because of non-linearity. The proposed scheme further derives its strength from the use of 3D-Lorenz transform in the frequency domain. Although the experimental setup for optical realization of the proposed scheme has been provided, the results presented here are based on simulations on MATLAB. It has been validated for grayscale images, and is found to be sensitive to the encryption parameters of the Lorenz system. The attacks analysis shows that the key-space is large enough to resist brute-force attack, and the scheme is also resistant to the noise and occlusion attacks. Statistical analysis and the analysis based on correlation distribution of adjacent pixels have been performed to test the efficacy of the encryption scheme. The results have indicated that the proposed encryption scheme possesses a high level of security.

  4. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    International Nuclear Information System (INIS)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco

    2012-01-01

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  5. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland); Laboratory for Micro and Nanotechnology, Paul Scherrer Institut, 5232 Villigen (Switzerland); Philips Technologie GmbH, Roentgenstrasse 24, 22335 Hamburg (Germany); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Radiology, Kantonsspital Baden, 5404 Baden (Switzerland); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Gynecology and Obstetrics, Interdisciplinary Breast Center Baden, Kantonsspital Baden, 5404 Baden (Switzerland); Swiss Light Source, Paul Scherrer Institut, 5232 Villigen, Switzerland and Institute for Biomedical Engineering, University and ETH Zuerich, 8092 Zuerich (Switzerland)

    2012-07-31

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  6. A contribution to the improvement of the intelligibility on scintigraphic images

    International Nuclear Information System (INIS)

    Cordier, Sylvaine.

    1975-01-01

    First of all the physical conditions necessary to obtain the image of a radioactivated organ are defined, after which the characteristics of these images are analyzed in order to suggest a suitable treatment for each type of degradation. The relationships between the different parameters of the system: object to be detected, noise in the measurement, pulse response of the system etc... are expressed in mathematical formulae. It is shown that the detection system as a whole may be considered with a very good approximation as a linear filter and the generality of this approach enables it to be applied to any imagery system. Since in morphological examinations an abnormal relief is looked for in the representation of an organ the use of digital computing methods was considered as a means of showing up these reliefs from a previously restored image and the information processing aspect of the problem is considered. The generalization of two-dimensional positive unfolding is not utopian and it is found that the number of calculation to be performed is only proportional to n even when a (nxn) image is obtained [fr

  7. Comparison of clinical imaging characteristics of 99mTc-EDDA/HYNIC-TOC with 111In-DTPA-octreotide: first result of a prospective phase II study

    International Nuclear Information System (INIS)

    Gabriel, M.; Decristoforo, C.; Wenger, M.; Guggenberg, E. von; Moncayo, R.; Mather, S.J.

    2002-01-01

    Full text: 99m Tc-EDDA/HYNIC-TOC(Tc-TOC) shows very similar clinical pharmacokinetics compared with 111 In-DTPA-octreotide (In-OCT), the gold standard for somatostatin receptor (SSTR) scintigraphy, and is a promising agent to image SSTR-positive tumors. Here we present the first results of a phase II trial comparing the clinical value of Tc-TOC in a prospective intra-patient comparison with In-OCT. Until now 26 oncological patients were enrolled in the study after giving informed consent. The patients presented with thyroid adeno-carcinomas (n=5), MW (n=3), GEP-tumors (n=10), carcinoid syndromes with unknown primary lesions (n=4), paragangliomas (n=2) and pituitary tumor (n=2), one of whom due to MEN. Posterior and anterior views and SPECT images of the corresponding ROIs were acquired at 4 hrs and 24 hrs alter injection of 111 MBq of In-OCT (octreoscan(r)). TcTOC was given at a dose of 300-350 MBq and imaging was done at 4 hrs p.i. including whole body planar and SPECT studies. Interpretations of these two sets of planar data were done independently by two different viewers. Final confirmation of suspected lesions was obtained by correlative inspection of matched CT or MR scans. In 7 patients SSTR-scintigraphy was negative with both Tc-TOC and In-OCT. Matching positive scintigraphic results with both tracers were obtained in 17 out of 19 patients. In-OCT failed to detect two CT-positive thoracic lesions in two patients with thyroid cancer, whereby these lesions were seen by Tc-TOC. In this series of patients 99m Tc-EDDA-HYNIC-TOC imaging resulted in equivalent diagnostic information on the SSTR-Status, with advantages of a single acquisition, one day protocol and lower radiation dose. The excellent imaging properties resulted in improved diagnosis in 2 of 26 patients when compared to 111 In-DTPA-octreotide. (author)

  8. Polarization Imaging Apparatus for Cell and Tissue Imaging and Diagnostics, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This work proposes to capitalize on our Phase I success in a novel visible-near infrared Stokes polarization imaging technology based on high performance fast...

  9. In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo

    International Nuclear Information System (INIS)

    Li Beilei; Xu Min; Shi Hongcheng; Chen Shaoliang; Wu Weizhong; Peng Guanyun; Zhang Xi; Peng Yifeng

    2012-01-01

    Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors. Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method. Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility. Barium sulfate and physiological saline were used as contrast agents for the blood vessels. Blood vessels of <Φ20 μm could be detected by replacing resident blood with physiological saline or barium sulfate. An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image. It is demonstrated that selective angiography based on phase contrast X-ray imaging, with a physiological material of low Z elements (such as saline) being the contrast agent, is a viable imaging strategy. Further efforts will be focused on using the technique to image tumor angiogenesis. (authors)

  10. Development of phase-contrast imaging technique for material science and medical science applications

    International Nuclear Information System (INIS)

    Kashyap, Y.S.; Roy, Tushar; Sarkar, P.S; Shukla, Mayank; Yadav, P.S; Sinha, Amar; Verma, Vishnu; Ghosh, A.K.

    2007-07-01

    In-line phase contrast imaging technique is an emerging method for study of materials such as carbon fibres, carbon composite materials, polymers etc. These represent the class of materials for which x-ray attenuation cross-section is very small. Similarly, this technique is also well suited for imaging of soft materials such as tissues, distinguishing between tumour and normal tissue. Thus this method promises a far better contrast for low x-ray absorbing substances than the conventional radiography method for material and medical science applications. Though the conventional radiography technique has been carried out for decades, the phase-imaging technique is being demonstrated for the first time within, the country. We have set up an experimental facility for phase contrast imaging using a combination of x-ray CCD detector and a microfocus x-ray source. This facility is dedicated for micro-imaging experiments such as micro-tomography and high resolution phase contrast experiments. In this report, the results of phase contrast imaging using microfocus source and ELETTRA, synchrotron source are discussed. We have also discussed the basic design and heat load calculation for upcoming imaging beamline at Indus-II, RRCAT, Indore. (author)

  11. Three-dimensional imaging using phase retrieval with two focus planes

    Science.gov (United States)

    Ilovitsh, Tali; Ilovitsh, Asaf; Weiss, Aryeh; Meir, Rinat; Zalevsky, Zeev

    2016-03-01

    This work presents a technique for a full 3D imaging of biological samples tagged with gold-nanoparticles (GNPs) using only two images, rather than many images per volume as is currently needed for 3D optical sectioning microscopy. The proposed approach is based on the Gerchberg-Saxton (GS) phase retrieval algorithm. The reconstructed field is free space propagated to all other focus planes using post processing, and the 2D z-stack is merged to create a 3D image of the sample with high fidelity. Because we propose to apply the phase retrieving on nano particles, the regular ambiguities typical to the Gerchberg-Saxton algorithm, are eliminated. In addition, since the method requires the capturing of two images only, it can be suitable for 3D live cell imaging. The proposed concept is presented and validated both on simulated data as well as experimentally.

  12. A simple image-reject mixer based on two parallel phase modulators

    Science.gov (United States)

    Hu, Dapeng; Zhao, Shanghong; Zhu, Zihang; Li, Xuan; Qu, Kun; Lin, Tao; Zhang, Kun

    2018-02-01

    A simple photonic microwave image-reject mixer (IRM) using two parallel phase modulators is proposed. First, a photonic microwave mixer with phase shift ability is achieved using two parallel phase modulators (PMs), an optical bandpass filter, three polarization controllers, three polarization beam splitters and two balanced photodetectors. At the output of the mixer, two frequency downconverted signals with tunable frequency difference can be obtained. By adjusting the phase difference as 90° and utilizing an electrical 90° hybrid, the useless components can be eliminated, and the image reject operation is realized. The key advantage of the proposed scheme is the usage of PM, which avoid the DC bias shifting problem and make the system simple and stable. A simulation is performed to verify the proposed scheme, a relative - 90° or 90° phase shift can be obtained between the two output ports of the photonic microwave mixer, at the output of the IRM, 60 dB image-reject ratio is obtained.

  13. Investigation of the imaging quality of synchrotron-based phase-contrast mammographic tomography

    International Nuclear Information System (INIS)

    Gureyev, T E; Mayo, S C; Nesterets, Ya I; Mohammadi, S; Menk, R H; Arfelli, F; Tromba, G; Lockie, D; Pavlov, K M; Kitchen, M J; Zanconati, F; Dullin, C

    2014-01-01

    We report the results of a systematic study of phase-contrast x-ray computed tomography in the propagation-based and analyser-based modes using specially designed phantoms and excised breast tissue samples. The study is aimed at the quantitative evaluation and subsequent optimization, with respect to detection of small tumours in breast tissue, of the effects of phase contrast and phase retrieval on key imaging parameters, such as spatial resolution, contrast-to-noise ratio, x-ray dose and a recently proposed ‘intrinsic quality’ characteristic which combines the image noise with the spatial resolution. We demonstrate that some of the methods evaluated in this work lead to substantial (more than 20-fold) improvement in the contrast-to-noise and intrinsic quality of the reconstructed tomographic images compared with conventional techniques, with the measured characteristics being in good agreement with the corresponding theoretical estimations. This improvement also corresponds to an approximately 400-fold reduction in the x-ray dose, compared with conventional absorption-based tomography, without a loss in the imaging quality. The results of this study confirm and quantify the significant potential benefits achievable in three-dimensional mammography using x-ray phase-contrast imaging and phase-retrieval techniques. (paper)

  14. Differential diagnosis of Parkinsonism using dual phase F 18 FP CIT PET imaging

    International Nuclear Information System (INIS)

    Jin, So Young; Oh, Min Young; Ok, Seung Jun; Oh, Jung Su; Lee, Sang Ju; Chung, Sun Ju; Lee, Chong Sik; Kim, Jae Seung

    2012-01-01

    Dopamine transporter (DAT) imaging can demonstrate presynaptic dopaminergic neuronal loss in Parkinson's disease (PD). However, differentiating atypical parkinsonism (APD) from PD is often difficult. We investigated the usefulness of dual phase F 18 FP CIT positron emission tomography (PET) imaging in the differential diagnosis of parkinsonism. Ninety eight subjects [five normal, seven drug induced parkinsonism (DIP), five essential tremor (ET), 24 PD, 20 multiple system atrophy parkinson type (MSA-P), 13 multiple system atrophy cerebellar type (MSA-C), 13 progressive supranuclear palsy (PSP), and 11 dementia with Lewy bodies(DLB)] underwent F 18 FP CIT PET. PET images were acquired at 5 min (early phase) and 3 h (late phase) after F 18 FP CIT administration (185MBq). Regional uptake pattern of cerebral and cerebellar hemispheres was assessed on early phase images, using visual, quantitative, and statistical parametric mapping (SPM) analyses. Striatal DAT binding was normal in normal, ET, DIP, and MSA C groups, but abnormal in PD, MSA P PSP, and DLB groups. No difference was found in regional uptake on early phase images among normal DAT binding groups, except in the MSA C group. Abnormal DAT binding groups showed different regional uptake pattern on early phase images compared with PD in SPM analysis (FDR<0.05). When discriminating APD from PD, visual interpretation of the early phase image showed high diagnostic sensitivity and specificity (75.4% and 100%, respectively). Regarding the ability to distinguish specific APD, sensitivities were 81% for MSA P, 77% for MSA C, 23% for PSP, and 54.5% for DLB. Dual phase F 18 FP CIT PET imaging is useful in demonstrating striatal DAT loss in neurodegenerative parkinsonism, and also in differentiating APD, particularly MSA, from PD

  15. Differential diagnosis of Parkinsonism using dual phase F 18 FP CIT PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jin, So Young; Oh, Min Young; Ok, Seung Jun; Oh, Jung Su; Lee, Sang Ju; Chung, Sun Ju; Lee, Chong Sik; Kim, Jae Seung [Univ. of Ulsan, Seoul (Korea, Republic of)

    2012-03-15

    Dopamine transporter (DAT) imaging can demonstrate presynaptic dopaminergic neuronal loss in Parkinson's disease (PD). However, differentiating atypical parkinsonism (APD) from PD is often difficult. We investigated the usefulness of dual phase F 18 FP CIT positron emission tomography (PET) imaging in the differential diagnosis of parkinsonism. Ninety eight subjects [five normal, seven drug induced parkinsonism (DIP), five essential tremor (ET), 24 PD, 20 multiple system atrophy parkinson type (MSA-P), 13 multiple system atrophy cerebellar type (MSA-C), 13 progressive supranuclear palsy (PSP), and 11 dementia with Lewy bodies(DLB)] underwent F 18 FP CIT PET. PET images were acquired at 5 min (early phase) and 3 h (late phase) after F 18 FP CIT administration (185MBq). Regional uptake pattern of cerebral and cerebellar hemispheres was assessed on early phase images, using visual, quantitative, and statistical parametric mapping (SPM) analyses. Striatal DAT binding was normal in normal, ET, DIP, and MSA C groups, but abnormal in PD, MSA P PSP, and DLB groups. No difference was found in regional uptake on early phase images among normal DAT binding groups, except in the MSA C group. Abnormal DAT binding groups showed different regional uptake pattern on early phase images compared with PD in SPM analysis (FDR<0.05). When discriminating APD from PD, visual interpretation of the early phase image showed high diagnostic sensitivity and specificity (75.4% and 100%, respectively). Regarding the ability to distinguish specific APD, sensitivities were 81% for MSA P, 77% for MSA C, 23% for PSP, and 54.5% for DLB. Dual phase F 18 FP CIT PET imaging is useful in demonstrating striatal DAT loss in neurodegenerative parkinsonism, and also in differentiating APD, particularly MSA, from PD.

  16. X-ray phase contrast imaging: From synchrotrons to conventional sources

    International Nuclear Information System (INIS)

    Olivo, A.; Castelli, E.

    2014-01-01

    Phase-based approaches can revolutionize X-ray imaging and remove its main limitation: poor image contrast arising from low attenuation differences. They exploit the unit decrement of the real part of the refractive index, typically 1000 times larger than the imaginary part driving attenuation. This increases the contrast of all details, and enables the detection of features classically considered 'X-ray invisible'. Following pioneering experiments dating back to the mid-sixties, X-ray phase contrast imaging 'exploded' in the mid-nineties, when third generation synchrotron sources became more widely available. Applications were proposed in fields as diverse as material science, palaeontology, biology, food science, cultural heritage preservation, and many others. Among these applications, medicine has been constantly considered the most important; among medical applications, mammography is arguably the one that attracted most attention. Applications to mammography were pioneered by the SYRMEP (SYnchrotron Radiation for MEdical Physics) group in Trieste, which was already active in the area through a combination of innovative ways to do imaging at synchrotrons and development of novel X-ray detectors. This pioneering phase led to the only clinical experience of phase contrast mammography on human patients, and spawned a number of ideas as to how these advances could be translated into clinical practice.

  17. Remote laboratory for phase-aided 3D microscopic imaging and metrology

    Science.gov (United States)

    Wang, Meng; Yin, Yongkai; Liu, Zeyi; He, Wenqi; Li, Boqun; Peng, Xiang

    2014-05-01

    In this paper, the establishment of a remote laboratory for phase-aided 3D microscopic imaging and metrology is presented. Proposed remote laboratory consists of three major components, including the network-based infrastructure for remote control and data management, the identity verification scheme for user authentication and management, and the local experimental system for phase-aided 3D microscopic imaging and metrology. The virtual network computer (VNC) is introduced to remotely control the 3D microscopic imaging system. Data storage and management are handled through the open source project eSciDoc. Considering the security of remote laboratory, the fingerprint is used for authentication with an optical joint transform correlation (JTC) system. The phase-aided fringe projection 3D microscope (FP-3DM), which can be remotely controlled, is employed to achieve the 3D imaging and metrology of micro objects.

  18. Scintigraphic appearance of stress-induced trauma of the dorsal cortex of the third metacarpal bone in racing Thoroughbred horses: 121 cases (1978-1986)

    International Nuclear Information System (INIS)

    Koblik, P.D.; Hornof, W.J.; Seeherman, H.J.

    1988-01-01

    Review of 121 bone scintigrams obtained on racing Thoroughbred horses with clinical histories indicative of forelimb lameness revealed 3 scintigraphic patterns of stress-induced trauma to the dorsal cortex of the third metacarpal bone: (1) focal, intense uptake associated with recent stress fracture; (2) regional uptake of varying intensity or a mixed pattern of uptake associated with chronic stress fracture; and (3) diffuse, mild to moderate uptake associated with periostitis (bucked shins). The latter scintigraphic pattern appeared to be an exaggerated manifestation of the normal remodeling process evident in immature horses (2 to 3 years old). Scintigraphy was most helpful in identifying radiographically occult stress fractures, determining the extent of cortical involvement before surgical intervention in cases of chronic stress fractures, and monitoring the fracture healing process

  19. Multiparticle imaging velocimetry measurements in two-phase flow

    International Nuclear Information System (INIS)

    Hassan, Y.A.

    1998-01-01

    The experimental flow visualization tool, Particle Image Velocimetry (PIV), is being extended to determine the velocity fields in two and three-dimensional, two-phase fluid flows. In the past few years, the technique has attracted quite a lot of interest. PIV enables fluid velocities across a region of a flow to be measured at a single instant in time in global domain. This instantaneous velocity profile of a given flow field is determined by digitally recording particle (microspheres or bubbles) images within the flow over multiple successive video frames and then conducting flow pattern identification and analysis of the data. This paper presents instantaneous velocity measurements in various two and three- dimensional, two-phase flow situations. (author)

  20. Phase accuracy evaluation for phase-shifting fringe projection profilometry based on uniform-phase coded image

    Science.gov (United States)

    Zhang, Chunwei; Zhao, Hong; Zhu, Qian; Zhou, Changquan; Qiao, Jiacheng; Zhang, Lu

    2018-06-01

    Phase-shifting fringe projection profilometry (PSFPP) is a three-dimensional (3D) measurement technique widely adopted in industry measurement. It recovers the 3D profile of measured objects with the aid of the fringe phase. The phase accuracy is among the dominant factors that determine the 3D measurement accuracy. Evaluation of the phase accuracy helps refine adjustable measurement parameters, contributes to evaluating the 3D measurement accuracy, and facilitates improvement of the measurement accuracy. Although PSFPP has been deeply researched, an effective, easy-to-use phase accuracy evaluation method remains to be explored. In this paper, methods based on the uniform-phase coded image (UCI) are presented to accomplish phase accuracy evaluation for PSFPP. These methods work on the principle that the phase value of a UCI can be manually set to be any value, and once the phase value of a UCI pixel is the same as that of a pixel of a corresponding sinusoidal fringe pattern, their phase accuracy values are approximate. The proposed methods provide feasible approaches to evaluating the phase accuracy for PSFPP. Furthermore, they can be used to experimentally research the property of the random and gamma phase errors in PSFPP without the aid of a mathematical model to express random phase error or a large-step phase-shifting algorithm. In this paper, some novel and interesting phenomena are experimentally uncovered with the aid of the proposed methods.

  1. Supplementary value of functional imaging in forensic medicine.

    Science.gov (United States)

    Mirzaei, Siroos; Sonneck-Koenne, Charlotte; Bruecke, Thomas; Aryana, Kamran; Knoll, Peter; Zakavi, Rasoul

    2012-01-01

    The aim of this study is to evaluate the role of functional imaging for forensic purposes. We reviewed a few outpatient cases that were sent to our department for examination after traumatic events and one case with neuropsychic disturbances. Functional imaging showed signs of traumatic lesions in the skeletal system, of brain metabolism and of renal failure. Functional disturbances following traumatic events are in some cases more important than morphological abnormalities. Targeted scintigraphic examinations could be applied for visualisation of traumatic lesions or evaluation of functional disturbances caused by traumatic events. These examinations can be used as evidence in the courtroom.

  2. Radionuclide imaging of the liver in human fascioliasis

    International Nuclear Information System (INIS)

    Rivera, J.V.; Bermudez, R.H.

    1984-01-01

    The clinical, laboratory, and scintigraphic findings in four cases of human fascioliasis are described. Acute onset of fever, abdominal pain, and weight loss in a person who has ingested watercress constitutes the clinical syndrome often seen. Eosinophilia and alteration in liver function tests, particularly alkaline phosphatase are frequent. Tc-99m sulfur colloid images showed hepatomegaly in four patients, focal defects in two, splenomegaly in three, and increased splenic uptake in two. Gallium citrate (Ga 67) images show increased uptake in the focal lesions in two of two. Sonographic imaging showed focal lucent abnormality in one of three. Liver biopsy findings were nonspecific. The differential diagnosis from other invasive parasitic diseases is discussed. A possible role of hepatic imaging in the evaluation of fascioliasis is suggested

  3. Imaging reporter gene for monitoring gene therapy

    International Nuclear Information System (INIS)

    Beco, V. de; Baillet, G.; Tamgac, F.; Tofighi, M.; Weinmann, P.; Vergote, J.; Moretti, J.L.; Tamgac, G.

    2002-01-01

    Scintigraphic images can be obtained to document gene function at cellular level. This approach is presented here and the use of a reporter gene to monitor gene therapy is described. Two main ways are presented: either the use of a reporter gene coding for an enzyme the action of which will be monitored by radiolabeled pro-drug, or a cellular receptor gene, the action of which is documented by a radio labeled cognate receptor ligand. (author)

  4. Versatile quantitative phase imaging system applied to high-speed, low noise and multimodal imaging (Conference Presentation)

    Science.gov (United States)

    Federici, Antoine; Aknoun, Sherazade; Savatier, Julien; Wattellier, Benoit F.

    2017-02-01

    Quadriwave lateral shearing interferometry (QWLSI) is a well-established quantitative phase imaging (QPI) technique based on the analysis of interference patterns of four diffraction orders by an optical grating set in front of an array detector [1]. As a QPI modality, this is a non-invasive imaging technique which allow to measure the optical path difference (OPD) of semi-transparent samples. We present a system enabling QWLSI with high-performance sCMOS cameras [2] and apply it to perform high-speed imaging, low noise as well as multimodal imaging. This modified QWLSI system contains a versatile optomechanical device which images the optical grating near the detector plane. Such a device is coupled with any kind of camera by varying its magnification. In this paper, we study the use of a sCMOS Zyla5.5 camera from Andor along with our modified QWLSI system. We will present high-speed live cell imaging, up to 200Hz frame rate, in order to follow intracellular fast motions while measuring the quantitative phase information. The structural and density information extracted from the OPD signal is complementary to the specific and localized fluorescence signal [2]. In addition, QPI detects cells even when the fluorophore is not expressed. This is very useful to follow a protein expression with time. The 10 µm spatial pixel resolution of our modified QWLSI associated to the high sensitivity of the Zyla5.5 enabling to perform high quality fluorescence imaging, we have carried out multimodal imaging revealing fine structures cells, like actin filaments, merged with the morphological information of the phase. References [1]. P. Bon, G. Maucort, B. Wattellier, and S. Monneret, "Quadriwave lateral shearing interferometry for quantitative phase microscopy of living cells," Opt. Express, vol. 17, pp. 13080-13094, 2009. [2] P. Bon, S. Lécart, E. Fort and S. Lévêque-Fort, "Fast label-free cytoskeletal network imaging in living mammalian cells," Biophysical journal, 106

  5. Implementation of neutron phase contrast imaging at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Klaus

    2008-11-12

    At ANTARES, the beam line for neutron imaging at the Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) in Garching, the option to do phase contrast imaging besides conventional absorption based neutron imaging was implemented and successfully used for the non-destructive testing of various types of objects. The used propagation-based technique is based on the interference of neutron waves in the detector plane that were differently strong diffracted by the sample. A comparison with other phase-sensitive neutron imaging techniques highlights assets and drawbacks of the different methods. In preliminary measurements at ANTARES and the spallation source SINQ at PSI in Villigen, the influence of the beam geometry, the neutron spectrum and the detector on the quality of the phase contrast measurements were investigated systematically. It was demonstrated that gamma radiation and epithermal neutrons in the beam contribute severely to background noise in measurements, which motivated the installation of a remotely controlled filter wheel for a quick and precise positioning of different crystal filters in the beam. By the installation of a similar aperture wheel, a quick change between eight different beam geometries was made possible. Besides pinhole and slit apertures, coded apertures based on non redundant arrays were investigated. The possibilities, which arise by the exploitation of the real part of the refractive index in neutron imaging, were demonstrated in experiments with especially designed test samples and in measurements with ordinary, industrial components. (orig.)

  6. Implementation of neutron phase contrast imaging at FRM-II

    International Nuclear Information System (INIS)

    Lorenz, Klaus

    2008-01-01

    At ANTARES, the beam line for neutron imaging at the Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) in Garching, the option to do phase contrast imaging besides conventional absorption based neutron imaging was implemented and successfully used for the non-destructive testing of various types of objects. The used propagation-based technique is based on the interference of neutron waves in the detector plane that were differently strong diffracted by the sample. A comparison with other phase-sensitive neutron imaging techniques highlights assets and drawbacks of the different methods. In preliminary measurements at ANTARES and the spallation source SINQ at PSI in Villigen, the influence of the beam geometry, the neutron spectrum and the detector on the quality of the phase contrast measurements were investigated systematically. It was demonstrated that gamma radiation and epithermal neutrons in the beam contribute severely to background noise in measurements, which motivated the installation of a remotely controlled filter wheel for a quick and precise positioning of different crystal filters in the beam. By the installation of a similar aperture wheel, a quick change between eight different beam geometries was made possible. Besides pinhole and slit apertures, coded apertures based on non redundant arrays were investigated. The possibilities, which arise by the exploitation of the real part of the refractive index in neutron imaging, were demonstrated in experiments with especially designed test samples and in measurements with ordinary, industrial components. (orig.)

  7. DIPSI: the diffraction image phase sensing instrument for APE

    Science.gov (United States)

    Montoya-Martínez, Luzma; Reyes, Marcos; Schumacher, Achim; Hernández, Elvio

    2006-06-01

    Large segmented mirrors require efficient co-phasing techniques in order to avoid the image degradation due to segments misalignment. For this purpose in the last few years new co-phasing techniques have been developed in collaboration with several European institutes. The Active Phasing Experiment (APE) will be a technical instrument aimed at testing different phasing techniques for an Extremely Large Telescope (ELT). A mirror composed of 61 hexagonal segments will be conjugated to the primary mirror of the VLT (Very Large Telescope). Each segment can be moved in piston, tip and tilt. Three new types of co-phasing sensors dedicated to the measurement of segmentation errors will be tested, evaluated and compared: ZEUS (Zernike Unit for Segment phasing) developed by LAM and IAC, PYPS (PYramid Phase Sensor) developed by INAF/ARCETRI, and DIPSI (Diffraction Image Phase Sensing Instrument) developed by IAC, GRANTECAN and LAM. This experiment will first run in the laboratory with point-like polychromatic sources and a turbulence generator. In a second step, it will be mounted at the Nasmyth platform focus of a VLT unit telescope. This paper describes the scientific concept of DIPSI, its optomechanical design, the signal analysis to retrieve segment piston and tip-tilt, the multiwavelength algorithm to increase the capture range, and the multiple segmentation case, including both simulation and laboratory tests results.

  8. Optimization of X-ray phase-contrast imaging based on in-line holography

    International Nuclear Information System (INIS)

    Wu Xizeng; Liu Hong; Yan Aimin

    2005-01-01

    This paper introduces a newly conceived formalism for clinical in-line phase-contrast X-ray imaging. The new formalism applies not only to ideal 'thin' objects analyzed in previous studies, but also applies to the real-world tissues used in actual clinical practice. Moreover we have identified the four clinically important factors that affect phase-contrast characteristics. These factors are: (1) body part attenuation (2) the spatial coherence of incident X-rays from an X-ray tube (3) the polychromatic nature of the X-ray source and (4) radiation dose to patients for clinical applications. Techniques of phase image-reconstruction based on the new X-ray in-line holography theory are discussed. Numerical simulations are described which were used to validate the theory. The design parameters of an optimal clinical phase-contrast mammographic imaging system which were determined based on the new theory, and validated in the simulations, are presented. The theory, image reconstruction algorithms, and numerical simulation techniques presented in this paper can be applied widely to clinical diagnostic X-ray imaging applications

  9. Measurement of Two-Phase Flow Fields by Application of Dynamic Electrical Impedance Imaging

    International Nuclear Information System (INIS)

    Kim, KyungYoun; Kang, Sook In; Kim, Ho Chan; Kim, Sin; Lee, Yoon Joon; Kim, Min Chan; Anghaie, Samim

    2002-01-01

    This study presents a visualization technique for the phase distribution in a two-phase flow field with an electrical impedance imaging technique, which reconstructs the resistivity distribution with electrical responses that are determined by corresponding excitations. Special emphasis is placed on the development of dynamic imaging technique for two-phase system undergoing a rapid transient, which could not be visualized with conventional static imaging techniques. The proposed algorithm treats the image reconstruction problem as a nonlinear state estimation problem and the unknown state (resistivity distribution, i.e. phase distribution) is estimated with the aid of a Kalman filter in a minimum mean square error sense. Several illustrative examples with computer simulations are successfully provided to verify the reconstruction performance of the proposed algorithm. (authors)

  10. Simultaneous transmission for an encrypted image and a double random-phase encryption key

    Science.gov (United States)

    Yuan, Sheng; Zhou, Xin; Li, Da-Hai; Zhou, Ding-Fu

    2007-06-01

    We propose a method to simultaneously transmit double random-phase encryption key and an encrypted image by making use of the fact that an acceptable decryption result can be obtained when only partial data of the encrypted image have been taken in the decryption process. First, the original image data are encoded as an encrypted image by a double random-phase encryption technique. Second, a double random-phase encryption key is encoded as an encoded key by the Rivest-Shamir-Adelman (RSA) public-key encryption algorithm. Then the amplitude of the encrypted image is modulated by the encoded key to form what we call an encoded image. Finally, the encoded image that carries both the encrypted image and the encoded key is delivered to the receiver. Based on such a method, the receiver can have an acceptable result and secure transmission can be guaranteed by the RSA cipher system.

  11. Recent advances in synchrotron-based hard x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Liu, Y; Nelson, J; Andrews, J C; Pianetta, P; Holzner, C

    2013-01-01

    Ever since the first demonstration of phase contrast imaging (PCI) in the 1930s by Frits Zernike, people have realized the significant advantage of phase contrast over conventional absorption-based imaging in terms of sensitivity to ‘transparent’ features within specimens. Thus, x-ray phase contrast imaging (XPCI) holds great potential in studies of soft biological tissues, typically containing low Z elements such as C, H, O and N. Particularly when synchrotron hard x-rays are employed, the favourable brightness, energy tunability, monochromatic characteristics and penetration depth have dramatically enhanced the quality and variety of XPCI methods, which permit detection of the phase shift associated with 3D geometry of relatively large samples in a non-destructive manner. In this paper, we review recent advances in several synchrotron-based hard x-ray XPCI methods. Challenges and key factors in methodological development are discussed, and biological and medical applications are presented. (paper)

  12. Recent advances in synchrotron-based hard x-ray phase contrast imaging

    Science.gov (United States)

    Liu, Y.; Nelson, J.; Holzner, C.; Andrews, J. C.; Pianetta, P.

    2013-12-01

    Ever since the first demonstration of phase contrast imaging (PCI) in the 1930s by Frits Zernike, people have realized the significant advantage of phase contrast over conventional absorption-based imaging in terms of sensitivity to ‘transparent’ features within specimens. Thus, x-ray phase contrast imaging (XPCI) holds great potential in studies of soft biological tissues, typically containing low Z elements such as C, H, O and N. Particularly when synchrotron hard x-rays are employed, the favourable brightness, energy tunability, monochromatic characteristics and penetration depth have dramatically enhanced the quality and variety of XPCI methods, which permit detection of the phase shift associated with 3D geometry of relatively large samples in a non-destructive manner. In this paper, we review recent advances in several synchrotron-based hard x-ray XPCI methods. Challenges and key factors in methodological development are discussed, and biological and medical applications are presented.

  13. Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

    Energy Technology Data Exchange (ETDEWEB)

    Rohkohl, Christopher; Bruder, Herbert; Stierstorfer, Karl [Siemens AG, Healthcare Sector, Siemensstrasse 1, 91301 Forchheim (Germany); Flohr, Thomas [Siemens AG, Healthcare Sector, Siemensstrasse 1, 91301 Forchheim (Germany); Institute of Diagnostic Radiology, Eberhard Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)

    2013-03-15

    Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum

  14. Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

    International Nuclear Information System (INIS)

    Rohkohl, Christopher; Bruder, Herbert; Stierstorfer, Karl; Flohr, Thomas

    2013-01-01

    Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum

  15. Fractional Fourier domain optical image hiding using phase retrieval algorithm based on iterative nonlinear double random phase encoding.

    Science.gov (United States)

    Wang, Xiaogang; Chen, Wen; Chen, Xudong

    2014-09-22

    We present a novel image hiding method based on phase retrieval algorithm under the framework of nonlinear double random phase encoding in fractional Fourier domain. Two phase-only masks (POMs) are efficiently determined by using the phase retrieval algorithm, in which two cascaded phase-truncated fractional Fourier transforms (FrFTs) are involved. No undesired information disclosure, post-processing of the POMs or digital inverse computation appears in our proposed method. In order to achieve the reduction in key transmission, a modified image hiding method based on the modified phase retrieval algorithm and logistic map is further proposed in this paper, in which the fractional orders and the parameters with respect to the logistic map are regarded as encryption keys. Numerical results have demonstrated the feasibility and effectiveness of the proposed algorithms.

  16. Classified study and clinical value of the phase imaging features

    International Nuclear Information System (INIS)

    Dang Yaping; Ma Aiqun; Zheng Xiaopu; Yang Aimin; Xiao Jiang; Gao Xinyao

    2000-01-01

    445 patients with various heart diseases were examined by the gated cardiac blood pool imaging, and the phase was classified. The relationship between the seven types with left ventricular function index, clinical heart function, different heart diseases as well as electrocardiograph was studied. The results showed that the phase image classification could match with the clinical heart function. It can visually, directly and accurately indicate clinical heart function and can be used to identify diagnosis of heart disease

  17. Imaging of metastatic lymph nodes by X-ray phase-contrast micro-tomography.

    Directory of Open Access Journals (Sweden)

    Torben Haugaard Jensen

    Full Text Available Invasive cancer causes a change in density in the affected tissue, which can be visualized by x-ray phase-contrast tomography. However, the diagnostic value of this method has so far not been investigated in detail. Therefore, the purpose of this study was, in a blinded manner, to investigate whether malignancy could be revealed by non-invasive x-ray phase-contrast tomography in lymph nodes from breast cancer patients. Seventeen formalin-fixed paraffin-embedded lymph nodes from 10 female patients (age range 37-83 years diagnosed with invasive ductal carcinomas were analyzed by X-ray phase-contrast tomography. Ten lymph nodes had metastatic deposits and 7 were benign. The phase-contrast images were analyzed according to standards for conventional CT images looking for characteristics usually only visible by pathological examinations. Histopathology was used as reference. The result of this study was that the diagnostic sensitivity of the image analysis for detecting malignancy was 100% and the specificity was 87%. The positive predictive value was 91% for detecting malignancy and the negative predictive value was 100%. We conclude that x-ray phase-contrast imaging can accurately detect density variations to obtain information regarding lymph node involvement previously inaccessible with standard absorption x-ray imaging.

  18. Preliminary results on scintigraphic evaluation of malignant external otitis

    International Nuclear Information System (INIS)

    Malamitsi, J.; Maragoudakis, P.; Papafragou, K.; Koukouliou, V.; Kalatzis, Y.; Adamopoulos, G.; Proukakis, C.

    1993-01-01

    Malignant external otitis (MEO) is a potentially fatal otitis occurring in diabetic and immunosuppressed patients, which may cause cranial nerve palsies and massive thrombophlebitis of the brain. We studied five diabetic patients with the clinical diagnosis of external otitis who were suspected of having MEO and one diabetic patient presumed cured from MEO. All of them underwent methylene diphosphonate, nanocolloid and gallium single-photon emission tomography studies with quantitative analysis on the basis of regions of interest and count profile curves. This combined assessment helped us to diagnose and follow-up soft tissue and temporal bone infection, especially in the case of transsphenoidal extension of the disease, since conventional radiology and computed tomography were of no particular help. On the basis of these results, we consider scintigraphic demonstration of skull base infection as a fourth criterion of MEO given that the classical Chandler's triad (diabetes, granuloma, and Pseudomonas aeruginosa) is not always present. (orig.)

  19. Pasteurized intercalary autogenous bone graft: radiographic and scintigraphic features

    International Nuclear Information System (INIS)

    Ehara, Shigeru; Tamakawa, Yoshiharu; Nishida, Jun; Shiraishi, Hideo

    2000-01-01

    Objective. Pasteurized autogenous bone graft sterilized at a low temperature (60 C) is one option for reconstruction after resection of bone and soft tissue tumors. The purpose of this investigation was to assess the normal and abnormal radiographic and scintigraphic findings of pasteurized intercalary autogenous bone graft after resection of bone and soft tissue sarcomas.Design. This was a retrospective evaluation of the radiography and bone scintigraphy findings in patients after treatment of bone and soft tissue sarcomas using an intercalary pasteurized autogenous bone graft.Patients. Among 10 consecutive patients, eight had intercalary grafts, and they constitute the subjects of this study. All available radiography and bone scintigraphy findings were reviewed for the healing process and the possibility of complications.Results and conclusions. Healing and incorporation of the graft were observed in five patients during the follow-up, but the other three did not heal satisfactorily. Rapid incorporation of pasteurized autogenous bone graft can be demonstrated by means of radiography and bone scintigraphy. (orig.)

  20. Contribution to scintigraphic study of pulmonary ventilation using 133Xe

    International Nuclear Information System (INIS)

    Chareyron, R.P.

    1975-01-01

    A technique of regional lung function study, using 133 Xe, is described (instrumentation, procedure, results). A gamma-camera is used for this investigation, its main advantages are as follows. The picture is smaller than the one produced by a scanner, but is obtained more quickly. The gamma-camera equipped with a data processing unit is able to visualize areas of interest and to provide quantitative informations. Two parameters are studied. The first one is Xenon washout speed expressed in (ml/mn/cm 3 ) which gives an exact value of pulmonary ventilation. The latter is retention. This parameter is of interest because retention is more easy to evaluate than washout speed, and is able to quantify what is suggested by scintigraphic pictures. The technique has proven to be valuable in differentiating chronic bronchitis from post-bronchitic emphysema [fr

  1. Qualification of a Null Lens Using Image-Based Phase Retrieval

    Science.gov (United States)

    Bolcar, Matthew R.; Aronstein, David L.; Hill, Peter C.; Smith, J. Scott; Zielinski, Thomas P.

    2012-01-01

    In measuring the figure error of an aspheric optic using a null lens, the wavefront contribution from the null lens must be independently and accurately characterized in order to isolate the optical performance of the aspheric optic alone. Various techniques can be used to characterize such a null lens, including interferometry, profilometry and image-based methods. Only image-based methods, such as phase retrieval, can measure the null-lens wavefront in situ - in single-pass, and at the same conjugates and in the same alignment state in which the null lens will ultimately be used - with no additional optical components. Due to the intended purpose of a Dull lens (e.g., to null a large aspheric wavefront with a near-equal-but-opposite spherical wavefront), characterizing a null-lens wavefront presents several challenges to image-based phase retrieval: Large wavefront slopes and high-dynamic-range data decrease the capture range of phase-retrieval algorithms, increase the requirements on the fidelity of the forward model of the optical system, and make it difficult to extract diagnostic information (e.g., the system F/#) from the image data. In this paper, we present a study of these effects on phase-retrieval algorithms in the context of a null lens used in component development for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Approaches for mitigation are also discussed.

  2. An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging.

    Science.gov (United States)

    Li, Guobin; Hennig, Jürgen; Raithel, Esther; Büchert, Martin; Paul, Dominik; Korvink, Jan G; Zaitsev, Maxim

    2015-10-01

    In most half-Fourier imaging methods, explicit phase replacement is used. In combination with parallel imaging, or compressed sensing, half-Fourier reconstruction is usually performed in a separate step. The purpose of this paper is to report that integration of half-Fourier reconstruction into iterative reconstruction minimizes reconstruction errors. The L1-norm phase constraint for half-Fourier imaging proposed in this work is compared with the L2-norm variant of the same algorithm, with several typical half-Fourier reconstruction methods. Half-Fourier imaging with the proposed phase constraint can be seamlessly combined with parallel imaging and compressed sensing to achieve high acceleration factors. In simulations and in in-vivo experiments half-Fourier imaging with the proposed L1-norm phase constraint enables superior performance both reconstruction of image details and with regard to robustness against phase estimation errors. The performance and feasibility of half-Fourier imaging with the proposed L1-norm phase constraint is reported. Its seamless combination with parallel imaging and compressed sensing enables use of greater acceleration in 3D MR imaging.

  3. Simulation of single grid-based phase-contrast x-ray imaging (g-PCXI)

    Energy Technology Data Exchange (ETDEWEB)

    Lim, H.W.; Lee, H.W. [Department of Radiation Convergence Engineering, iTOMO Group, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 26493 (Korea, Republic of); Cho, H.S., E-mail: hscho1@yonsei.ac.kr [Department of Radiation Convergence Engineering, iTOMO Group, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 26493 (Korea, Republic of); Je, U.K.; Park, C.K.; Kim, K.S.; Kim, G.A.; Park, S.Y.; Lee, D.Y.; Park, Y.O.; Woo, T.H. [Department of Radiation Convergence Engineering, iTOMO Group, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon-do 26493 (Korea, Republic of); Lee, S.H.; Chung, W.H.; Kim, J.W.; Kim, J.G. [R& D Center, JPI Healthcare Co., Ltd., Ansan 425-833 (Korea, Republic of)

    2017-04-01

    Single grid-based phase-contrast x-ray imaging (g-PCXI) technique, which was recently proposed by Wen et al. to retrieve absorption, scattering, and phase-gradient images from the raw image of the examined object, seems a practical method for phase-contrast imaging with great simplicity and minimal requirements on the setup alignment. In this work, we developed a useful simulation platform for g-PCXI and performed a simulation to demonstrate its viability. We also established a table-top setup for g-PCXI which consists of a focused-linear grid (200-lines/in strip density), an x-ray tube (100-μm focal spot size), and a flat-panel detector (48-μm pixel size) and performed a preliminary experiment with some samples to show the performance of the simulation platform. We successfully obtained phase-contrast x-ray images of much enhanced contrast from both the simulation and experiment and the simulated contract seemed similar to the experimental contrast, which shows the performance of the developed simulation platform. We expect that the simulation platform will be useful for designing an optimal g-PCXI system. - Highlights: • It is proposed for the single grid-based phase-contrast x-ray imaging (g-PCXI) technique. • We implemented for a numerical simulation code. • The preliminary experiment with several samples to compare is performed. • It is expected to be useful to design an optimal g-PCXI system.

  4. Clinical implementation of x-ray phase-contrast imaging: Theoretical foundations and design considerations

    International Nuclear Information System (INIS)

    Wu Xizeng; Liu Hong

    2003-01-01

    Theoretical foundation and design considerations of a clinical feasible x-ray phase contrast imaging technique were presented in this paper. Different from the analysis of imaging phase object with weak absorption in literature, we proposed a new formalism for in-line phase-contrast imaging to analyze the effects of four clinically important factors on the phase contrast. These are the body parts attenuation, the spatial coherence of spherical waves from a finite-size focal spot, and polychromatic x-ray and radiation doses to patients for clinical applications. The theory presented in this paper can be applied widely in diagnostic x-ray imaging procedures. As an example, computer simulations were conducted and optimal design parameters were derived for clinical mammography. The results of phantom experiments were also presented which validated the theoretical analysis and computer simulations

  5. ESR imaging investigations of two-phase systems.

    Science.gov (United States)

    Herrmann, Werner; Stösser, Reinhard; Borchert, Hans-Hubert

    2007-06-01

    The possibilities of electron spin resonance (ESR) and electron spin resonance imaging (ESRI) for investigating the properties of the spin probes TEMPO and TEMPOL in two-phase systems have been examined in the systems water/n-octanol, Miglyol/Miglyol, and Precirol/Miglyol. Phases and regions of the phase boundary could be mapped successfully by means of the isotropic hyperfine coupling constants, and, moreover, the quantification of rotational and lateral diffusion of the spin probes was possible. For the quantitative treatment of the micropolarity, a simplified empirical model was established on the basis of the Nernst distribution and the experimentally determined isotropic hyperfine coupling constants. The model does not only describe the summarized micropolarities of coexisting phases, but also the region of the phase boundary, where solvent molecules of different polarities and tendencies to form hydrogen bonds compete to interact with the NO group of the spin probe. Copyright 2007 John Wiley & Sons, Ltd.

  6. High Temperature Fiberoptic Thermal Imaging System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Phase 1 program will fabricate and demonstrate a small diameter single fiber endoscope that can perform high temperature thermal imaging in a jet engine...

  7. Multi-phase imaging of intermittency at steady state using differential imaging method by X-ray micro-tomography

    Science.gov (United States)

    Gao, Y.; Lin, Q.; Bijeljic, B.; Blunt, M. J.

    2017-12-01

    To observe intermittency in consolidated rock, we image a steady state flow of brine and decane in Bentheimer sandstone. We devise an experimental method based on X-ray differential imaging method to examine how changes in flow rate impact the pore-scale distribution of fluids during co-injection flow under dynamic flow conditions at steady state. This helps us elucidate the diverse flow regimes (connected, intermittent break-up, or continual break-up of the non-wetting phase pathways) for two capillary numbers. Also, relative permeability curves under both capillary and viscous limited conditions could be measured. We have performed imbibition sample floods using oil-brine and measured steady state relative permeability on a sandstone rock core in order to fully characterize the flow behaviour at low and high Ca. Two sets of experiments at high and low flow rates are provided to explore the time-evolution of the non-wetting phase clusters distribution under different flow conditions. The high flow rate is 0.5 mL/min, whose corresponding capillary number is 7.7×10-6. The low flow rate is 0.02 mL/min, whose capillary number is 3.1×10-7. A procedure based on using high-salinity brine as the contrast phase and applying differential imaging between the dry scan and that of the sample saturation with a 30 wt% Potassium iodide (KI) doped brine help to make sure there is no non-wetting phase in micro-pores. Then the intermittent phase in multiphase flow image at high Ca can be quantified by obtaining the differential image between the 30 wt% KI brine image and the scans that taken at each fixed fractional flow. By using the grey scale histogram distribution of the raw images at each condition, the oil proportion in the intermittent phase can be calculated. The pressure drops at each fractional flow at low and high Ca can be measured by high-precision pressure differential sensors and utilized to calculate to the relative permeability at pore scale. The relative

  8. Low dose reconstruction algorithm for differential phase contrast imaging.

    Science.gov (United States)

    Wang, Zhentian; Huang, Zhifeng; Zhang, Li; Chen, Zhiqiang; Kang, Kejun; Yin, Hongxia; Wang, Zhenchang; Marco, Stampanoni

    2011-01-01

    Differential phase contrast imaging computed tomography (DPCI-CT) is a novel x-ray inspection method to reconstruct the distribution of refraction index rather than the attenuation coefficient in weakly absorbing samples. In this paper, we propose an iterative reconstruction algorithm for DPCI-CT which benefits from the new compressed sensing theory. We first realize a differential algebraic reconstruction technique (DART) by discretizing the projection process of the differential phase contrast imaging into a linear partial derivative matrix. In this way the compressed sensing reconstruction problem of DPCI reconstruction can be transformed to a resolved problem in the transmission imaging CT. Our algorithm has the potential to reconstruct the refraction index distribution of the sample from highly undersampled projection data. Thus it can significantly reduce the dose and inspection time. The proposed algorithm has been validated by numerical simulations and actual experiments.

  9. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  10. Software for imaging phase-shift interference microscope

    Science.gov (United States)

    Malinovski, I.; França, R. S.; Couceiro, I. B.

    2018-03-01

    In recent years absolute interference microscope was created at National Metrology Institute of Brazil (INMETRO). The instrument by principle of operation is imaging phase-shifting interferometer (PSI) equipped with two stabilized lasers of different colour as traceable reference wavelength sources. We report here some progress in development of the software for this instrument. The status of undergoing internal validation and verification of the software is also reported. In contrast with standard PSI method, different methodology of phase evaluation is applied. Therefore, instrument specific procedures for software validation and verification are adapted and discussed.

  11. Is 123-J-heptadecanoic acid suitable for routine diagnostic myocardial imaging

    International Nuclear Information System (INIS)

    Sauer, J.

    1984-01-01

    2 mCi of 123-I-HDA were injected with the patient reclining. Static images were obtained at 400.000 counts in the ap, 45 degree and 60 degree LAO and the left lateral projections. To reduce penetration effects a 400 KeV collimator was used. At 30 minutes p.i. images were repeated in the same sequence. After background correction and smoothing color print-outs were obtained. Counts rates were analyzed across myocardial areas with normal and reduced uptake and fatty acid retention and elimination were determined. Scintigraphic data were compared with measured results. In terms of the diagnostic information obtainable, early images are comparable to 201-T1 scans after stress exposure, but superior to 201-T1 scans at rest. 123-I-HDA retention images recorded at 30 minutes p.i. often correspond to T1-201 scans at rest. Ischemic areas usually show a more pronounced retention than well perfused areas. Findings are comparable with the socalled redistribution phenomenon on 201-T1 stress scanning. Data obtained are correlated with experimental results by others. 123-I-HDA has been found to be particularly usefule for patients unable to tolerate stress. Image quality was often superior to that on 201-T1 stress studies. The title question can, therefore, be answered in the affirmative. Patients did not complain of subjective side effects. A reproducible imaging technique and swift working during early phase imaging as essential. Generating parametric statistical images to detect normal and abnormal fatty acid turnover is our next goal. (Author)

  12. Scintigraphic characteristics of experimental myocardial infarct extension

    International Nuclear Information System (INIS)

    Kronenberg, M.W.; Wooten, N.E.; Friesinger, G.C.; Page, D.L.; Higgins, S.B.; Collins, J.C.; O'Connor, J.L.; Price, R.R.; Brill, A.B.

    1979-01-01

    Technetium-99m-stannous pyrophosphate scintiphotos were evaluated for diagnosing and quantitating myocardial infarct (MI) extension in sedated dogs. Infarction and extension were produced by serial left anterior descending coronary artery ligations at 0 and 48 hours. We compared serial scintiphoto data with regional myocardial blood flow (MBF) (microsphere technique) and infarct histopathology. In eight control dogs, the scintigraphic MI area was stable at 24, 48, and 72 hours. In each of 11 dogs undergoing extension, the MI area increased after the 48-hour occlusion, averaging a 48.9% increase (p < 0.001). Grossly, most extensions were mixtures of confluent necrosis and moderate (patchy) necrosis. MBF to confluent infarct tissue decreased significantly, allowing the documentation of extension by totaling the grams of newly flow-deprived tissue, but patchy infarct tissue had little flow deprivation, making it difficult to quantitate this type of extension accurately by flow criteria alone. Rarely, extension could be diagnosed using conventional histologic criteria. We concluded that the scintiphoto MI area was related quantitatively to infarct weight in both control and extension. However, it was not possible to determine that an increase in the MI scintiphoto area was an accurate predictor of the degree of extension using independent flow or pathologic criteria

  13. Testicular radionuclide angiography and sttatic imaging: anatomy, scintigraphic interpretation, and clinical indications

    International Nuclear Information System (INIS)

    Holder, L.E.; Martire, J.R.; Holmes, E.R. III.; Wagner, H.N. Jr.

    1977-01-01

    Radionuclide testicular angiography and static imaging is an easy, rapidly performed study. Its usefulness in separating acute testicular torsion from acute epididymitis has been confirmed. Increased angiographic perfusion with definition of the testicular and deferential arteries in the spermatic cord and the pudendal artery posteriorly is equated with inflammation. Intense increased vascularity on the blood pool image is seen in abscess and acute inflammation, while cases of tumor and trauma have mild increases. Acute or missed testicular torsion, uncomplicated hydroceles, and spermatoceles show absent vascularity. On the static images, decreased activity is characteristic of the shape and location of the avascular structure. Technical factors are stressed

  14. From Relativistic Electrons to X-ray Phase Contrast Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Garson, A. B. [Washington U., St. Louis; Anastasio, M. A. [Washington U., St. Louis

    2017-10-09

    We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 μm (FWHM)) with the 25-mm diameter single crystals than the reference polycrystalline phosphor’s 80-μm value. Potential fiber-optic plate depth-of-focus aspects and 33-μm diameter carbon fiber imaging are also addressed.

  15. Phase-image-based content-addressable holographic data storage

    Science.gov (United States)

    John, Renu; Joseph, Joby; Singh, Kehar

    2004-03-01

    We propose and demonstrate the use of phase images for content-addressable holographic data storage. Use of binary phase-based data pages with 0 and π phase changes, produces uniform spectral distribution at the Fourier plane. The absence of strong DC component at the Fourier plane and more intensity of higher order spatial frequencies facilitate better recording of higher spatial frequencies, and improves the discrimination capability of the content-addressable memory. This improves the results of the associative recall in a holographic memory system, and can give low number of false hits even for small search arguments. The phase-modulated pixels also provide an opportunity of subtraction among data pixels leading to better discrimination between similar data pages.

  16. Quantitative Evaluation of Scintillation Camera Imaging Characteristics of Isotopes Used in Liver Radioembolization

    Science.gov (United States)

    Elschot, Mattijs; Nijsen, Johannes Franciscus Wilhelmus; Dam, Alida Johanna; de Jong, Hugo Wilhelmus Antonius Maria

    2011-01-01

    Background Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment planning and post-treatment dosimetry. The aim of this study is to quantitatively evaluate and compare the imaging characteristics of these three isotopes, in order that imaging protocols can be optimized and RE studies with varying isotopes can be compared. Methodology/Principal Findings Phantom experiments were performed in line with NEMA guidelines to assess the spatial resolution, sensitivity, count rate linearity, and contrast recovery of 99mTc, 90Y and 166Ho. In addition, Monte Carlo simulations were performed to obtain detailed information about the history of detected photons. The results showed that the use of a broad energy window and the high-energy collimator gave optimal combination of sensitivity, spatial resolution, and primary photon fraction for 90Y Bremsstrahlung imaging, although differences with the medium-energy collimator were small. For 166Ho, the high-energy collimator also slightly outperformed the medium-energy collimator. In comparison with 99mTc, the image quality of both 90Y and 166Ho is degraded by a lower spatial resolution, a lower sensitivity, and larger scatter and collimator penetration fractions. Conclusions/Significance The quantitative evaluation of the scintillation camera characteristics presented in this study helps to optimize acquisition parameters and supports future analysis of clinical comparisons between RE studies. PMID:22073149

  17. Renal imaging in paediatrics

    International Nuclear Information System (INIS)

    Porn, U.; Hahn, K.; Fischer, S.

    2003-01-01

    The most frequent renal diseases in paediatrics include urinary tract infections, hydronephrosis, kidney anomalies and reflux. The main reason for performing DMSA scintigraphy in paediatrics is the detection of cortical abnormalities related to urinary tract infection. Because the amount of tracer retained in the tubular cells is associated with the distribution of functioning renal parenchyma in the kidney, it is possible, to evaluate the split renal function. In comparison to ultrasound and intravenous urography the sensitivity in the detection of acute as well as chronic inflammatory changes is very high, however less specific. An indication for a renography in neonates and children is beside an estimation of the total renal function and the calculation of the split renal function, the assessment of renal drainage in patients with unclear dilatation of the collecting system in ultrasound. The analysis of the time activity curve provides, especially for follow-up studies, a reproducible method to assess the urinary outflow. The diuretic scintigraphy allows the detection of urinary obstruction. Subsequently it is possible to image the micturition phase to detect vesico-ureteric reflux (indirect MCU) after drainage of tracer from the renal pelvis. An reflux in the ureters or the pelvicalyceal system is visible on the scintigraphic images and can be confirmed by time activity curves. A more invasive technique is the direct isotope cystography with bladder catheterization. The present paper should give an overview about the role of nuclear medicine in paediatric urology. (orig.) [de

  18. Phase correction of MR perfusion/diffusion images

    International Nuclear Information System (INIS)

    Chenevert, T.L.; Pipe, J.G.; Brunberg, J.A.; Yeung, H.N.

    1989-01-01

    Apparent diffusion coefficient (ADC) and perfusion MR sequences are exceptionally sensitive to minute motion and, therefore, are prone to bulk motions that hamper ADC/perfusion quantification. The authors have developed a phase correction algorithm to substantially reduce this error. The algorithm uses a diffusion-insensitive data set to correct data that are diffusion sensitive but phase corrupt. An assumption of the algorithm is that bulk motion phase shifts are uniform in one dimension, although they may be arbitrarily large and variable from acquisition to acquisition. This is facilitated by orthogonal section selection. The correction is applied after one Fourier transform of a two-dimensional Fourier transform reconstruction. Imaging experiments on rat and human brain demonstrate significant artifact reduction in ADC and perfusion measurements

  19. Identification of Hürthle cell tumor by single-injection, double-phase scintigraphy with technetium-99m-sestamibi.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A

    1995-05-01

    Early and late (double-phase) scintigraphy with 99mTc-MIBI was used in a comparative study of the scintigraphic aspects of Hürthle cell tumors and other thyroid tumors. Single-injection, dual-phase (15-30 min and 3-4 hr) thyroid scintigraphy with 99mTc-sestamibi (MIBI) was performed on 41 patients who displayed a cold nodule on previous 99mTc scintigraphy. Visual scoring of nodular uptake was done to compare thyroidal and background tracer uptake. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late images and the washout rate from the nodule (WON) and thyroidal tissue (WOT) were measured. Cytologic results were obtained for all patients; histopathologic results were obtained for the 20 patients who had surgery. In eight patients (Group A), the nodule displayed intense and persistent uptake of MIBI (N/T = 1.77 +/- 0.46 and 3.20 +/- 1.37; WON = 17.2% +/- 6.3%; WOT = 24.6% +/- 7.5%); histopathology revealed Hürthle cell tumors (two carcinomas and three adenomas) in five surgical patients. In 15 patients (Group B), the nodule displayed intense uptake in the early image with fading activity in the late image (N/T = 1.45 +/- 0.54 and 0.84 +/- 0.30; WON = 30.0% +/- 7.3%; WOT = 24.5% +/- 6.8%); histopathology revealed a colloid nodule (n = 1), papillary carcinoma (n = 4) and follicular carcinoma (n = 5) in 10 surgical patients. In the remaining 18 patients (Group C), the nodule was cold and late images were not acquired. Histopathology revealed colloid nodules (n = 2) and follicular adenoma (n = 3) in five surgical patients. Single-injection, dual-phase MIBI scintigraphy of the thyroid can identify Hürthle cell tumors because these tumors have intense, persistent tracer uptake in contrast to other thyroid tumors.

  20. Thermal hydraulics-I. 1. Phasic Discrimination in Two-Phase-Flow Measurements Using Particle Image Velocimetry

    International Nuclear Information System (INIS)

    Todd, D.R.; Ortiz-Villafuerte, J.; Schmidl, W.D.; Hassan, Y.A.; Sanchez-Silva, F.

    2001-01-01

    Information about the dispersed phase parameters -such as location, displacement, and interfacial area -are very important in the analysis of two-phase flows. Local flow disturbances in the continuous phase can be quite significant when the dispersed phase (i.e., a particle, drop, or bubble) passes through the medium. Application of point-wise measurement methods such as hot wire anemometry and laser anemometry suffer significant limitations in two-phase-flow measurements when these local disturbances are strong. Also, these two methods typically lack the ability to quantify the dispersed phase. Previous work has shown that meaningful analysis of the instantaneous continuous phase velocity field requires knowledge of the dispersed phase parameters, especially location and trajectory. Continuous phase parameters such as the local instantaneous vorticity and local turbulence fluctuations are influenced by the passage of the dispersed phase. Thus, development of two-phase-flow models (such as a bubble wake model) requires knowledge of the relative location of a local continuous phase parameter to the dispersed flow object (i.e., directly behind or off the side of the object). Also, conditional sampling must be performed using a meaningful parameter as the sampling point, i.e., the passage of a specific size of bubble. A system has been developed at Texas A and M University to quantify the dispersed phase parameters for two-phase bubbly flow in a vertical pipe with co-current upward flow. This system uses an orthogonal shadow particle image velocimetry (SPIV) technique, which instantaneously measures three-dimensional bubble locations, volumes, and interfacial areas -while measuring the three-dimensional bubble velocities and accelerations over a sequence of discrete measurements. The SPIV system is capable of analyzing flows with a large number of bubbles in close proximity. A set of sample images has been collected as part of the preliminary testing and development

  1. Scintigraphic Evaluation in Primary Hyperparathyroidism

    International Nuclear Information System (INIS)

    Ghita, S.; Mazilu, C.; Marinescu, G.; Mititelu, R.; Rambu, A.; Murgoci, P.; Codorean, I.

    2006-01-01

    corresponding to those found at bone scan (left femur, right humerus, patellae); another focal uptake in the right shoulder region, visible on the posterior image. Further investigations: US, IRM, CT confirm the presence of tumour and provide precise data regarding the morphology and localization: a tumour of 50/34/25 mm with solid and cystic components and benign features developed in the left anterior cervical space, between trachea, cervical vessels and SCM, in contact with the inferior pole of the left thyroid lobe. CT of right shoulder region confirms the presence of a tumour the right scapula with features consistent with the diagnosis of brown tumour. There is also a tumour developed on the posterior aspect of the right humerus. PTH 1248.0 pg/ml (N 15-65). Minimal surgical intervention tumour ablation, followed by normalization of calcium levels. Histopathology: parathyroid adenoma. Favourable evolution of clinical and laboratory parameters. Discussion. Clinical presentation was unspecific and misleading. Based on the 'metabolic' information, bone scan was able suggest the correct diagnosis and to reorient the entire management of this patient. However, we took into account all data available: benign aspect of bone lesions on Rx, the high number of giant cells of osteoclastic type in the previously assessed tumor were concordant with the diagnostic. The scintigraphic examination with 'metabolic' radiotracer was able to identify the presence of a parathyroid adenoma. Early whole body acquisitions revealed sites of osteitis fibrosa cystica/brown tumours with better accuracy than bone scan. Further investigations were necessary to confirm the presence of tumour and to provide useful data regarding the morphology and localization. Conclusions. Bone scan has to be mandatory in the evaluation of all bone tumours, being a simple diagnostic tool which provides data about the number and localization of bone lesions, but also regarding the metabolic status of the skeleton. The

  2. A Multispectral Photon-Counting Double Random Phase Encoding Scheme for Image Authentication

    Directory of Open Access Journals (Sweden)

    Faliu Yi

    2014-05-01

    Full Text Available In this paper, we propose a new method for color image-based authentication that combines multispectral photon-counting imaging (MPCI and double random phase encoding (DRPE schemes. The sparsely distributed information from MPCI and the stationary white noise signal from DRPE make intruder attacks difficult. In this authentication method, the original multispectral RGB color image is down-sampled into a Bayer image. The three types of color samples (red, green and blue color in the Bayer image are encrypted with DRPE and the amplitude part of the resulting image is photon counted. The corresponding phase information that has nonzero amplitude after photon counting is then kept for decryption. Experimental results show that the retrieved images from the proposed method do not visually resemble their original counterparts. Nevertheless, the original color image can be efficiently verified with statistical nonlinear correlations. Our experimental results also show that different interpolation algorithms applied to Bayer images result in different verification effects for multispectral RGB color images.

  3. A multispectral photon-counting double random phase encoding scheme for image authentication.

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu; Lee, Yeon H

    2014-05-20

    In this paper, we propose a new method for color image-based authentication that combines multispectral photon-counting imaging (MPCI) and double random phase encoding (DRPE) schemes. The sparsely distributed information from MPCI and the stationary white noise signal from DRPE make intruder attacks difficult. In this authentication method, the original multispectral RGB color image is down-sampled into a Bayer image. The three types of color samples (red, green and blue color) in the Bayer image are encrypted with DRPE and the amplitude part of the resulting image is photon counted. The corresponding phase information that has nonzero amplitude after photon counting is then kept for decryption. Experimental results show that the retrieved images from the proposed method do not visually resemble their original counterparts. Nevertheless, the original color image can be efficiently verified with statistical nonlinear correlations. Our experimental results also show that different interpolation algorithms applied to Bayer images result in different verification effects for multispectral RGB color images.

  4. Scintigraphic detection of remote transmural myocardial infarction with thallium-201

    International Nuclear Information System (INIS)

    Silber, S.; Fleck, E.; Bierner, M.; Klein, U.; Rudolph, W.

    1979-01-01

    This study was undertaken to assess the value of the thallium-201-scintigram in the detection of remote myocardial infarction with respect to localization and extent as well as the degree of impairment of left ventricular wall motion. 114 patients with typical history of infarction, unequivocal ECG changes and angiographically-documented irreversible asynergy were investigated and 25 healthy subjects served as controls. Electrocardiographic classification of infarction as extensive or non-extensive was based on number of leads involved. The thallium-201-scintigrams were visually analyzed for evaluation of each of 3 segments in all 6 recorded projections. The angiograms were evaluated with respect to regional wall motion derived for the semi-axis shortening of the 3 corresponding scintigraphic segments in the right and left anterior oblique projections. Standard classification of localization and degree of asynergy were employed. (orig.) 891 AJ/orig. 892 MB [de

  5. Design of a compact high-energy setup for x-ray phase-contrast imaging

    Science.gov (United States)

    Schüttler, Markus; Yaroshenko, Andre; Bech, Martin; Potdevin, Guillaume; Malecki, Andreas; Chabior, Michael; Wolf, Johannes; Tapfer, Arne; Meiser, Jan; Kunka, Danays; Amberger, Maximilian; Mohr, Jürgen; Pfeiffer, Franz

    2014-03-01

    The main shortcoming of conventional biomedical x-ray imaging is the weak soft-tissue contrast caused by the small differences in the absorption coefficients between different materials. This issue can be addressed by x-ray phasesensitive imaging approaches, e.g. x-ray Talbot-Lau grating interferometry. The advantage of the three-grating Talbot-Lau approach is that it allows to acquire x-ray phase-contrast and dark-field images with a conventional lab source. However, through the introduction of the grating interferometer some constraints are imposed on the setup geometry. In general, the grating pitch and the mean x-ray energy determine the setup dimensions. The minimal length of the setup increases linearly with energy and is proportional to p2, where p is the grating pitch. Thus, a high-energy (100 keV) compact grating-based setup for x-ray imaging can be realized only if gratings with aspect-ratio of approximately 300 and a pitch of 1-2 μm were available. However, production challenges limit the availability of such gratings. In this study we consider the use of non-binary phase-gratings as means of designing a more compact grating interferometer for phase-contrast imaging. We present simulation and experimental data for both monochromatic and polychromatic case. The results reveal that phase-gratings with triangular-shaped structures yield visibilities that can be used for imaging purposes at significantly shorter distances than binary gratings. This opens the possibility to design a high-energy compact setup for x-ray phase-contrast imaging. Furthermore, we discuss different techniques to achieve triangular-shaped phase-shifting structures.

  6. Segmentation and classification of cell cycle phases in fluorescence imaging.

    Science.gov (United States)

    Ersoy, Ilker; Bunyak, Filiz; Chagin, Vadim; Cardoso, M Christina; Palaniappan, Kannappan

    2009-01-01

    Current chemical biology methods for studying spatiotemporal correlation between biochemical networks and cell cycle phase progression in live-cells typically use fluorescence-based imaging of fusion proteins. Stable cell lines expressing fluorescently tagged protein GFP-PCNA produce rich, dynamically varying sub-cellular foci patterns characterizing the cell cycle phases, including the progress during the S-phase. Variable fluorescence patterns, drastic changes in SNR, shape and position changes and abundance of touching cells require sophisticated algorithms for reliable automatic segmentation and cell cycle classification. We extend the recently proposed graph partitioning active contours (GPAC) for fluorescence-based nucleus segmentation using regional density functions and dramatically improve its efficiency, making it scalable for high content microscopy imaging. We utilize surface shape properties of GFP-PCNA intensity field to obtain descriptors of foci patterns and perform automated cell cycle phase classification, and give quantitative performance by comparing our results to manually labeled data.

  7. Phase distribution measurements in narrow rectangular channels using image processing techniques

    International Nuclear Information System (INIS)

    Bentley, C.; Ruggles, A.

    1991-01-01

    Many high flux research reactor fuel assemblies are cooled by systems of parallel narrow rectangular channels. The HFIR is cooled by single phase forced convection under normal operating conditions. However, two-phase forced convection or two phase mixed convection can occur in the fueled region as a result of some hypothetical accidents. Such flow conditions would occur only at decay power levels. The system pressure would be around 0.15 MPa in such circumstances. Phase distribution of air-water flow in a narrow rectangular channel is examined using image processing techniques. Ink is added to the water and clear channel walls are used to allow high speed still photographs and video tape to be taken of the air-water flow field. Flow field images are digitized and stored in a Macintosh 2ci computer using a frame grabber board. Local grey levels are related to liquid thickness in the flow channel using a calibration fixture. Image processing shareware is used to calculate the spatially averaged liquid thickness from the image of the flow field. Time averaged spatial liquid distributions are calculated using image calculation algorithms. The spatially averaged liquid distribution is calculated from the time averaged spatial liquid distribution to formulate the combined temporally and spatially averaged fraction values. The temporally and spatially averaged liquid fractions measured using this technique compare well to those predicted from pressure gradient measurements at zero superficial liquid velocity

  8. Causes of appearance of scintigraphic hot areas on thyroid scintigraphy analyzed with clinical features and comparative ultrasonographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Masahiro [Hikone Municipal Hospital, Shiga (Japan); Kasagi, Kanji [Takamatsu Red Cross Hospital, Kagawa (Japan); Hatabu, Hiroto [Univ. of Pennsylvania Medical Center, PA (United States); Misaki, Takashi; Iida, Yasuhiro; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Graduate School of Medicine

    2002-06-01

    This study was done retrospectively to analyze the ultrasonographic (US) findings in thyroid scintigraphic hot areas (HA). Three-thousand, eight-hundred and thirty-nine consecutive patients who underwent {sup 99m}Tc-pertechnetate (n=3435) or {sup 123}I (n=457) scintigraphy were analyzed. HA were regarded as present when the tracer concentration was greater than the remaining thyroid tissue, or when hemilobar uptake was observed. High-resolution US examinations were performed with a real-time electronic linear scanner with a 7.5 or 10 MHz transducer. One hundred and four (2.7%) were found to be scintigraphic HA (n=120). US revealed a nodular lesion or well-demarcated thyroid tissue corresponding to the HA in 94 areas (78.4%, Category 1), an ill-defined region with different echogenicity in 13 areas (10.8%, Category 2), and no correlating lesion in 13 areas (10.8%, Category 3). These 104 patients included 43 with adenomatous goiter (59 areas), 33 with adenoma, 11 with Hashimoto's thyroiditis, 5 with primary thyroid cancer, 4 with euthyroid ophthalmic Graves' disease (EOG), 3 with hemilobar atrophy or hypogenesis, 2 with hemilobar agenesis, 2 with hypothyroidism with blocking-type TSH-receptor antibodies (TSHRAb), 1 with acute suppurative thyroiditis. Among the 59 adenomatous nodules and 33 adenomas, 51 (86.4%) and 32 (97.0%), respectively, belonged to Category 1. A solitary toxic nodule was significantly larger and occurs more often in older patients than in younger patients. On the other hand, all 17 patients with known autoimmune thyroid diseases including Hashimoto's thyroiditis, EOG and hypothyroidism with blocking TSHRAb belonged to Category 2 or 3. Possible underlying mechanisms are hyperfunctioning tumors or nodules, localized functioning thyroid tissue freed from autoimmune destruction, inflammation or tumor invasion, congenital abnormality, clusters of hyperactive follicular cells caused by long-term TSH and/or TSHRAb stimulation, asymmetry

  9. Causes of appearance of scintigraphic hot areas on thyroid scintigraphy analyzed with clinical features and comparative ultrasonographic findings

    International Nuclear Information System (INIS)

    Iwata, Masahiro; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Fujita, Toru; Konishi, Junji

    2002-01-01

    This study was done retrospectively to analyze the ultrasonographic (US) findings in thyroid scintigraphic hot areas (HA). Three-thousand, eight-hundred and thirty-nine consecutive patients who underwent 99m Tc-pertechnetate (n=3435) or 123 I (n=457) scintigraphy were analyzed. HA were regarded as present when the tracer concentration was greater than the remaining thyroid tissue, or when hemilobar uptake was observed. High-resolution US examinations were performed with a real-time electronic linear scanner with a 7.5 or 10 MHz transducer. One hundred and four (2.7%) were found to be scintigraphic HA (n=120). US revealed a nodular lesion or well-demarcated thyroid tissue corresponding to the HA in 94 areas (78.4%, Category 1), an ill-defined region with different echogenicity in 13 areas (10.8%, Category 2), and no correlating lesion in 13 areas (10.8%, Category 3). These 104 patients included 43 with adenomatous goiter (59 areas), 33 with adenoma, 11 with Hashimoto's thyroiditis, 5 with primary thyroid cancer, 4 with euthyroid ophthalmic Graves' disease (EOG), 3 with hemilobar atrophy or hypogenesis, 2 with hemilobar agenesis, 2 with hypothyroidism with blocking-type TSH-receptor antibodies (TSHRAb), 1 with acute suppurative thyroiditis. Among the 59 adenomatous nodules and 33 adenomas, 51 (86.4%) and 32 (97.0%), respectively, belonged to Category 1. A solitary toxic nodule was significantly larger and occurs more often in older patients than in younger patients. On the other hand, all 17 patients with known autoimmune thyroid diseases including Hashimoto's thyroiditis, EOG and hypothyroidism with blocking TSHRAb belonged to Category 2 or 3. Possible underlying mechanisms are hyperfunctioning tumors or nodules, localized functioning thyroid tissue freed from autoimmune destruction, inflammation or tumor invasion, congenital abnormality, clusters of hyperactive follicular cells caused by long-term TSH and/or TSHRAb stimulation, asymmetry, etc. Scintigraphic HA are

  10. Causes of appearance of scintigraphic hot areas on thyroid scintigraphy analyzed with clinical features and comparative ultrasonographic findings.

    Science.gov (United States)

    Iwata, Masahiro; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Fujita, Toru; Konishi, Junji

    2002-06-01

    This study was done retrospectively to analyze the ultrasonographic (US) findings in thyroid scintigraphic hot areas (HA). Three-thousand, eight-hundred and thirty-nine consecutive patients who underwent 99mTc-pertechnetate (n = 3435) or 123I (n = 457) scintigraphy were analyzed. HA were regarded as present when the tracer concentration was greater than the remaining thyroid tissue, or when hemilobar uptake was observed. High-resolution US examinations were performed with a real-time electronic linear scanner with a 7.5 or 10 MHz transducer. One hundred and four (2.7%) were found to be scintigraphic HA (n = 120). US revealed a nodular lesion or well-demarcated thyroid tissue corresponding to the HA in 94 areas (78.4%, Category 1), an ill-defined region with different echogenicity in 13 areas (10.8%, Category 2), and no correlating lesion in 13 areas (10.8%, Category 3). These 104 patients included 43 with adenomatous goiter (59 areas), 33 with adenoma, 11 with Hashimoto's thyroiditis, 5 with primary thyroid cancer, 4 with euthyroid ophthalmic Graves' disease (EOG), 3 with hemilobar atrophy or hypogenesis, 2 with hemilobar agenesis, 2 with hypothyroidism with blocking-type TSH-receptor antibodies (TSHRAb), I with acute suppurative thyroiditis. Among the 59 adenomatous nodules and 33 adenomas, 51 (86.4%) and 32 (97.0%), respectively, belonged to Category 1. A solitary toxic nodule was significantly larger and occurs more often in older patients than in younger patients. On the other hand, all 17 patients with known autoimmune thyroid diseases including Hashimoto's thyroiditis, EOG and hypothyroidism with blocking TSHRAb belonged to Category 2 or 3. Possible underlying mechanisms are 1) hyperfunctioning tumors or nodules, 2) localized functioning thyroid tissue freed from autoimmune destruction, inflammation or tumor invasion, 3) congenital abnormality, 4) clusters of hyperactive follicular cells caused by long-term TSH and/or TSHRAb stimulation, 5) asymmetry, etc

  11. Genetic Algorithm Phase Retrieval for the Systematic Image-Based Optical Alignment Testbed

    Science.gov (United States)

    Taylor, Jaime; Rakoczy, John; Steincamp, James

    2003-01-01

    Phase retrieval requires calculation of the real-valued phase of the pupil fimction from the image intensity distribution and characteristics of an optical system. Genetic 'algorithms were used to solve two one-dimensional phase retrieval problem. A GA successfully estimated the coefficients of a polynomial expansion of the phase when the number of coefficients was correctly specified. A GA also successfully estimated the multiple p h e s of a segmented optical system analogous to the seven-mirror Systematic Image-Based Optical Alignment (SIBOA) testbed located at NASA s Marshall Space Flight Center. The SIBOA testbed was developed to investigate phase retrieval techniques. Tiphilt and piston motions of the mirrors accomplish phase corrections. A constant phase over each mirror can be achieved by an independent tip/tilt correction: the phase Conection term can then be factored out of the Discrete Fourier Tranform (DFT), greatly reducing computations.

  12. Differentiation of osteoporotic and neoplastic vertebral fractures by chemical shift {in-phase and out-of phase} MR imaging

    International Nuclear Information System (INIS)

    Ragab, Yasser; Emad, Yasser; Gheita, Tamer; Mansour, Maged; Abou-Zeid, A.; Ferrari, Serge; Rasker, Johannes J.

    2009-01-01

    Objective: The objective of this study was to establish the cut-off value of the signal intensity drop on chemical shift magnetic resonance imaging (MRI) with appropriate sensitivity and specificity to differentiate osteoporotic from neoplastic wedging of the spine. Patients and methods: All patients with wedging of vertebral bodies were included consecutively between February 2006 and January 2007. A chemical shift MRI was performed and signal intensity after (in-phase and out-phase) images were obtained. A DXA was performed in all. Results: A total of 40 patients were included, 20 with osteoporotic wedging (group 1) and 20 neoplastic (group 2). They were 21 males and 19 females. Acute vertebral collapse was observed in 15 patients in group 1 and subacute collapse in another 5 patients, while in group 2, 11 patients showed acute collapse and 9 patients (45%) showed subacute vertebral collapse. On the chemical shift MRI a substantial reduction in signal intensity was found in all lesions in both groups. The proportional changes observed in signal intensity of bone marrow lesions on in-phase compared with out-of-phase images showed significant differences in both groups (P < 0.05). At a cut-off value of 35%, the observed sensitivity of out-of-phase images was 95%, specificity was 100%, positive predictive value was 100% and negative predictive value was 95.2%. Conclusion: A chemical shift MRI is useful in order to differentiate patients with vertebral collapse due to underlying osteoporosis or neoplastic process.

  13. Whole body imaging in the abdominal cancer patient: pitfalls of PET-CT.

    LENUS (Irish Health Repository)

    McDermott, Shaunagh

    2012-02-01

    Proper interpretation of PET-CT images requires knowledge of the normal physiological distribution of the tracer, frequently encountered physiological variants, and benign pathological causes of FDG uptake that can be confused with a malignant neoplasm. In addition, not all malignant processes are associated with avid tracer uptake. A basic knowledge of the technique of image acquisition is also required to avoid pitfalls such as misregistration of anatomical and scintigraphic data. This article reviews these potential pitfalls as they apply to the abdomen and pelvis of patients with cancer.

  14. Joint Processing of Envelope Alignment and Phase Compensation for Isar Imaging

    Science.gov (United States)

    Chen, Tao; Jin, Guanghu; Dong, Zhen

    2018-04-01

    Range envelope alignment and phase compensation are spilt into two isolated parts in the classical methods of translational motion compensation in Inverse Synthetic Aperture Radar (ISAR) imaging. In classic method of the rotating object imaging, the two reference points of the envelope alignment and the Phase Difference (PD) estimation are probably not the same point, making it difficult to uncouple the coupling term by conducting the correction of Migration Through Resolution Cell (MTRC). In this paper, an improved approach of joint processing which chooses certain scattering point as the sole reference point is proposed to perform with utilizing the Prominent Point Processing (PPP) method. With this end in view, we firstly get the initial image using classical methods from which a certain scattering point can be chose. The envelope alignment and phase compensation using the selected scattering point as the same reference point are subsequently conducted. The keystone transform is thus smoothly applied to further improve imaging quality. Both simulation experiments and real data processing are provided to demonstrate the performance of the proposed method compared with classical method.

  15. Exogenous Molecular Probes for Targeted Imaging in Cancer: Focus on Multi-modal Imaging

    International Nuclear Information System (INIS)

    Joshi, Bishnu P.; Wang, Thomas D.

    2010-01-01

    Cancer is one of the major causes of mortality and morbidity in our healthcare system. Molecular imaging is an emerging methodology for the early detection of cancer, guidance of therapy, and monitoring of response. The development of new instruments and exogenous molecular probes that can be labeled for multi-modality imaging is critical to this process. Today, molecular imaging is at a crossroad, and new targeted imaging agents are expected to broadly expand our ability to detect and manage cancer. This integrated imaging strategy will permit clinicians to not only localize lesions within the body but also to manage their therapy by visualizing the expression and activity of specific molecules. This information is expected to have a major impact on drug development and understanding of basic cancer biology. At this time, a number of molecular probes have been developed by conjugating various labels to affinity ligands for targeting in different imaging modalities. This review will describe the current status of exogenous molecular probes for optical, scintigraphic, MRI and ultrasound imaging platforms. Furthermore, we will also shed light on how these techniques can be used synergistically in multi-modal platforms and how these techniques are being employed in current research

  16. Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

    International Nuclear Information System (INIS)

    Li, Ke; Ge, Yongshuai; Garrett, John; Bevins, Nicholas; Zambelli, Joseph; Chen, Guang-Hong

    2014-01-01

    Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS

  17. Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

    Science.gov (United States)

    Li, Ke; Ge, Yongshuai; Garrett, John; Bevins, Nicholas; Zambelli, Joseph; Chen, Guang-Hong

    2014-01-01

    Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS

  18. Triple Arterial Phase MR Imaging with Gadoxetic Acid Using a Combination of Contrast Enhanced Time Robust Angiography, Keyhole, and Viewsharing Techniques and Two-Dimensional Parallel Imaging in Comparison with Conventional Single Arterial Phase

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Lee, Jeong Min [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03087 (Korea, Republic of); Yu, Mi Hye [Department of Radiology, Konkuk University Medical Center, Seoul 05030 (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Seoul 04342 (Korea, Republic of); Han, Joon Koo [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03087 (Korea, Republic of)

    2016-11-01

    To determine whether triple arterial phase acquisition via a combination of Contrast Enhanced Time Robust Angiography, keyhole, temporal viewsharing and parallel imaging can improve arterial phase acquisition with higher spatial resolution than single arterial phase gadoxetic-acid enhanced magnetic resonance imaging (MRI). Informed consent was waived for this retrospective study by our Institutional Review Board. In 752 consecutive patients who underwent gadoxetic acid-enhanced liver MRI, either single (n = 587) or triple (n = 165) arterial phases was obtained in a single breath-hold under MR fluoroscopy guidance. Arterial phase timing was assessed, and the degree of motion was rated on a four-point scale. The percentage of patients achieving the late arterial phase without significant motion was compared between the two methods using the χ{sup 2} test. The late arterial phase was captured at least once in 96.4% (159/165) of the triple arterial phase group and in 84.2% (494/587) of the single arterial phase group (p < 0.001). Significant motion artifacts (score ≤ 2) were observed in 13.3% (22/165), 1.2% (2/165), 4.8% (8/165) on 1st, 2nd, and 3rd scans of triple arterial phase acquisitions and 6.0% (35/587) of single phase acquisitions. Thus, the late arterial phase without significant motion artifacts was captured in 96.4% (159/165) of the triple arterial phase group and in 79.9% (469/587) of the single arterial phase group (p < 0.001). Triple arterial phase imaging may reliably provide adequate arterial phase imaging for gadoxetic acid-enhanced liver MRI.

  19. Triple arterial phase MR imaging with gadoxetic acid using a combination of contrast enhanced time robust angiography, keyhole, and viewsharing techniques and two-dimensional parallel imaging in comparison with conventional single arterial phase

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Lee, Jeong Min; Han, Joon Koo [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Yu, Mi Hye [Dept. of Radiology, Konkuk University Medical Center, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2016-07-15

    To determine whether triple arterial phase acquisition via a combination of Contrast Enhanced Time Robust Angiography, keyhole, temporal viewsharing and parallel imaging can improve arterial phase acquisition with higher spatial resolution than single arterial phase gadoxetic-acid enhanced magnetic resonance imaging (MRI). Informed consent was waived for this retrospective study by our Institutional Review Board. In 752 consecutive patients who underwent gadoxetic acid-enhanced liver MRI, either single (n = 587) or triple (n = 165) arterial phases was obtained in a single breath-hold under MR fluoroscopy guidance. Arterial phase timing was assessed, and the degree of motion was rated on a four-point scale. The percentage of patients achieving the late arterial phase without significant motion was compared between the two methods using the χ2 test. The late arterial phase was captured at least once in 96.4% (159/165) of the triple arterial phase group and in 84.2% (494/587) of the single arterial phase group (p < 0.001). Significant motion artifacts (score ≤ 2) were observed in 13.3% (22/165), 1.2% (2/165), 4.8% (8/165) on 1st, 2nd, and 3rd scans of triple arterial phase acquisitions and 6.0% (35/587) of single phase acquisitions. Thus, the late arterial phase without significant motion artifacts was captured in 96.4% (159/165) of the triple arterial phase group and in 79.9% (469/587) of the single arterial phase group (p < 0.001). Triple arterial phase imaging may reliably provide adequate arterial phase imaging for gadoxetic acid-enhanced liver MRI.

  20. Initial studies of synchrotron radiation phase-contrast imaging in the field of medicine

    International Nuclear Information System (INIS)

    Chen Shaoliang; Zhang Xi; Peng Yifeng; Li Beilei; Cheng Aiping; Zhu Peiping; Yuan Xiqing; Huang Wanxia

    2010-01-01

    Recently,research on using X-ray phase information in medicine has been growing remarkably fast. Phase-contrast imaging with synchrotron radiation can reveal inner soft tissues such as tendons, cartilage, ligaments, adipose tissue, vessels and nerves without a contrast agent. We have visualized the liver, bile duct, lung, kidney, stomach and intestine, heart, blood vessel, bone and arthrosis, and tumor tissues using 'in-line' phase contrast imaging and diffraction-enhanced imaging. It is seen that the synchrotron radiation graphs show much higher resolution. This method is especially suitable for studying soft tissue structure and blood vessels. (authors)

  1. Scintigraphic imaging of focal hypoxic tissue: development and clinical applications of 123I-IAZA

    Directory of Open Access Journals (Sweden)

    Leonard I. Wiebe

    2002-09-01

    Full Text Available Affected tissues in a number of diseases, including cancer, stroke, cardiac infarction and diabetes, develop focal tissue hypoxia during their progression. The presence of hypoxic tissue may make the disease refractory to therapy, as in the case of solid tumor therapy using low LET ionizing radiation. In other pathologies, the detection of viable but hypoxic tissues may serve as a prodromal indicator of developing disease (e.g. diabetes,or as a prognostic indicator for management of the disease (e.g. stroke. Over the past two decades, a number of hypoxia radioimaging agents have been developed and tested clinically. Of these, 18F-Fmiso and 123I-IAZA are the most widely used radiotracers for PET and SPECT/planar imaging, respectively. IAZA and Fmiso are a 2-nitroimidazoles that chemically bind to subcellular components of viable hypoxic tissues. They sensitize hypoxic tumour to the killing effects of ionizing radiation via mechanisms that mimic the radiosensitizing effects of oxygen, and are therefore called oxygen mimetics. The oxygen mimetic effect is attributable in large part to the covalent binding of reductively-activated nitroimidazole intermediates to critical cellular macromolecules. Nitroimidazoles labelled with gamma-emitting radionuclides (e.g. 18F-Fmiso and 123I-IAZA have been used as scintigraphic markers of tumour hypoxia, based on the need to identify radioresistant hypoxic tumour cells as part of the radiotherapy planning process. Broader interest in non-invasive, imaging-based identification of focal hypoxia in a number of diseases has extended hypoxia studies to include peripheral vascular disease associated with diabetes, rheumatoid arthritis, stroke, myocardial ischaemia, brain trauma and oxidative stress. In this review, the current status of hypoxia-selective studies with 123I-IAZA , an experimental diagnostic radiopharmaceutical, is reviewed with respect to its pre-clinical development and clinical applications.Os tecidos

  2. Sequential processing of quantitative phase images for the study of cell behaviour in real-time digital holographic microscopy.

    Science.gov (United States)

    Zikmund, T; Kvasnica, L; Týč, M; Křížová, A; Colláková, J; Chmelík, R

    2014-11-01

    Transmitted light holographic microscopy is particularly used for quantitative phase imaging of transparent microscopic objects such as living cells. The study of the cell is based on extraction of the dynamic data on cell behaviour from the time-lapse sequence of the phase images. However, the phase images are affected by the phase aberrations that make the analysis particularly difficult. This is because the phase deformation is prone to change during long-term experiments. Here, we present a novel algorithm for sequential processing of living cells phase images in a time-lapse sequence. The algorithm compensates for the deformation of a phase image using weighted least-squares surface fitting. Moreover, it identifies and segments the individual cells in the phase image. All these procedures are performed automatically and applied immediately after obtaining every single phase image. This property of the algorithm is important for real-time cell quantitative phase imaging and instantaneous control of the course of the experiment by playback of the recorded sequence up to actual time. Such operator's intervention is a forerunner of process automation derived from image analysis. The efficiency of the propounded algorithm is demonstrated on images of rat fibrosarcoma cells using an off-axis holographic microscope. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  3. Demonstration of Focusing Wolter Mirrors for Neutron Phase and Magnetic Imaging

    Directory of Open Access Journals (Sweden)

    Daniel S. Hussey

    2018-03-01

    Full Text Available Image-forming focusing mirrors were employed to demonstrate their applicability to two different modalities of neutron imaging, phase imaging with a far-field interferometer, and magnetic-field imaging through the manipulation of the neutron beam polarization. For the magnetic imaging, the rotation of the neutron polarization in the magnetic field was measured by placing a solenoid at the focus of the mirrors. The beam was polarized upstream of the solenoid, while the spin analyzer was situated between the solenoid and the mirrors. Such a polarized neutron microscope provides a path toward considerably improved spatial resolution in neutron imaging of magnetic materials. For the phase imaging, we show that the focusing mirrors preserve the beam coherence and the path-length differences that give rise to the far-field moiré pattern. We demonstrated that the visibility of the moiré pattern is modified by small angle scattering from a highly porous foam. This experiment demonstrates the feasibility of using Wolter optics to significantly improve the spatial resolution of the far-field interferometer.

  4. Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging

    Science.gov (United States)

    Willner, M.; Herzen, J.; Grandl, S.; Auweter, S.; Mayr, D.; Hipp, A.; Chabior, M.; Sarapata, A.; Achterhold, K.; Zanette, I.; Weitkamp, T.; Sztrókay, A.; Hellerhoff, K.; Reiser, M.; Pfeiffer, F.

    2014-04-01

    X-ray phase-contrast imaging has received growing interest in recent years due to its high capability in visualizing soft tissue. Breast imaging became the focus of particular attention as it is considered the most promising candidate for a first clinical application of this contrast modality. In this study, we investigate quantitative breast tissue characterization using grating-based phase-contrast computed tomography (CT) at conventional polychromatic x-ray sources. Different breast specimens have been scanned at a laboratory phase-contrast imaging setup and were correlated to histopathology. Ascertained tumor types include phylloides tumor, fibroadenoma and infiltrating lobular carcinoma. Identified tissue types comprising adipose, fibroglandular and tumor tissue have been analyzed in terms of phase-contrast Hounsfield units and are compared to high-quality, high-resolution data obtained with monochromatic synchrotron radiation, as well as calculated values based on tabulated tissue properties. The results give a good impression of the method’s prospects and limitations for potential tumor detection and the associated demands on such a phase-contrast breast CT system. Furthermore, the evaluated quantitative tissue values serve as a reference for simulations and the design of dedicated phantoms for phase-contrast mammography.

  5. The value of scintigraphic examinations in the diagnosis of pathologic processes in the posterior scala in childhood and youth

    International Nuclear Information System (INIS)

    Piepgras, U.; Huber, G.; Emde, H.

    1980-01-01

    The diagnostical possibilities of computerized tomography (CT) and brain scintigraphy are compared. Serial scintigraphy by gamma cameras, scintigraphic examinations of the liquor space and the ventricles are discussed, too. In addition to CT, scintigraphy is also recommended in the following cases: hydrocephalus of unknown origin, dilatation of the IVth ventricle, diagnosis of recidive tumours, and unclear density differences. (L.E.)

  6. Lesion localization in patients with hyperparathyroidism using double-phase Tc-99m MIBI parathyroid scintigraphy

    International Nuclear Information System (INIS)

    Shin, Jung Woo; Ryu, Jin Sook; Kim, Jae Seung; Moon, Dae Hyuk; Hong, Seung Mo; Gong, Gyung Yub; Hong, Suk Joon; Lee, Hee Kyung

    1999-01-01

    This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of early and delayed images were 46.7% (7/15), 76.9% (10/13), 70% (7/10) and 66.7% (10/15), 92.3% (12/13), 90.9% (10/11), respectively. SPECT image detected an additional small hyperplasia. The sensitivity, specificity, and positive predictive value of combined interpretation of early and delayed images with SPECT were 73.3% (11/15), 100% (13/13), 100% (11/11). The sensitivity was 100% (6/6) for adenoma, whereas that was 55.5% (5/9) for hyperplasia. Both adenomas and hyperplasias showed significantly increased oxyphil cell contents compared with normal parathyroid glands (p<0.0001), but the oxyphil cell content and weight were not significantly different between adenomas and hyperplasias. Double-phase Tc-99m MIBI parathyroid scintigraphy with SPECT is useful for lesion localization in patients with hyperparathyroidism. Although both adenoma and hyperplasia have increased oxyphil cell content, the sensitivity is high in adenoma, but low in hyperplasia

  7. Correlation of early-phase 18F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    International Nuclear Information System (INIS)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju; Huang, Chin-Chang; Hsu, Wen-Chun; Yen, Tzu-Chen; Kung, Mei-Ping

    2012-01-01

    18 F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R 1 ) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R 1 images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R 1 and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R 1 images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R 1 . A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R 1 and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  8. JUPITER’S PHASE VARIATIONS FROM CASSINI : A TESTBED FOR FUTURE DIRECT-IMAGING MISSIONS

    International Nuclear Information System (INIS)

    Mayorga, L. C.; Jackiewicz, J.; Rages, K.; West, R. A.; Knowles, B.; Lewis, N.; Marley, M. S.

    2016-01-01

    We present empirical phase curves of Jupiter from ∼0° to 140° as measured in multiple optical bandpasses by Cassini /Imaging Science Subsystem (ISS) during the Millennium flyby of Jupiter in late 2000 to early 2001. Phase curves are of interest for studying the energy balance of Jupiter and understanding the scattering behavior of the planet as an exoplanet analog. We find that Jupiter is significantly darker at partial phases than an idealized Lambertian planet by roughly 25% and is not well fit by Jupiter-like exoplanet atmospheric models across all wavelengths. We provide analytic fits to Jupiter’s phase function in several Cassini /ISS imaging filter bandpasses. In addition, these observations show that Jupiter’s color is more variable with phase angle than predicted by models. Therefore, the color of even a near Jupiter-twin planet observed at a partial phase cannot be assumed to be comparable to that of Jupiter at full phase. We discuss how the Wide-Field Infrared Survey Telescope and other future direct-imaging missions can enhance the study of cool giants.

  9. Quantitative phase imaging of living cells with a swept laser source

    Science.gov (United States)

    Chen, Shichao; Zhu, Yizheng

    2016-03-01

    Digital holographic phase microscopy is a well-established quantitative phase imaging technique. However, interference artifacts from inside the system, typically induced by elements whose optical thickness are within the source coherence length, limit the imaging quality as well as sensitivity. In this paper, a swept laser source based technique is presented. Spectra acquired at a number of wavelengths, after Fourier Transform, can be used to identify the sources of the interference artifacts. With proper tuning of the optical pathlength difference between sample and reference arms, it is possible to avoid these artifacts and achieve sensitivity below 0.3nm. Performance of the proposed technique is examined in live cell imaging.

  10. Photon-counting-based diffraction phase microscopy combined with single-pixel imaging

    Science.gov (United States)

    Shibuya, Kyuki; Araki, Hiroyuki; Iwata, Tetsuo

    2018-04-01

    We propose a photon-counting (PC)-based quantitative-phase imaging (QPI) method for use in diffraction phase microscopy (DPM) that is combined with a single-pixel imaging (SPI) scheme (PC-SPI-DPM). This combination of DPM with the SPI scheme overcomes a low optical throughput problem that has occasionally prevented us from obtaining quantitative-phase images in DPM through use of a high-sensitivity single-channel photodetector such as a photomultiplier tube (PMT). The introduction of a PMT allowed us to perform PC with ease and thus solved a dynamic range problem that was inherent to SPI. As a proof-of-principle experiment, we performed a comparison study of analogue-based SPI-DPM and PC-SPI-DPM for a 125-nm-thick indium tin oxide (ITO) layer coated on a silica glass substrate. We discuss the basic performance of the method and potential future modifications of the proposed system.

  11. Comparative functional scintigraphic and angiographic examination in pancreas diseases

    International Nuclear Information System (INIS)

    Mendizov, A.; Brilski, V.; Bozhiyanov, A.; Romanova, A.; Mardzhanov, I.; Glavincheva, I.; Meditsinska Akademiya, Sofia

    1979-01-01

    Pancreas scintigraphy with 75 seleno-methionine, pancreocimine-secretine test and selective abdominal angiography was carried out in patients with chronic pancreatitis, pancreas carcinoma and subjects without any pancreas diseases. Scintigraphic changes in pancreas was found in 95,6 per cent of the patients with chronic pancreatitis (136 patients), in 92 per cent of them with pancreas carcinoma (25 patients) and in 53,4 per cent from the subjects without pancreas diseases (30 examined). Pathological changes in pancreatic secretion was found in 93,4 per cent of the patients with chronic pancreatitis (105 patients), in 93,8 per cent of the subjects with pancreas carcinoma (32 patients) and only in 3,9 per cent from the examined without pancreatic diseases. The angiographic examination is informative mainly in case of tumours and cysts of the pancreas. The diagnostic potentialities of the separate methods for pancreas examination were critically assessed. The basic diagnostic problems in pancreas diseases are solved to a great extent with the combined examination with scintigraphy pancreocimine test and angiography (76 patients). (author)

  12. X-ray elastography: Modification of x-ray phase contrast images using ultrasonic radiation pressure

    International Nuclear Information System (INIS)

    Hamilton, Theron J.; Bailat, Claude; Rose-Petruck, Christoph; Diebold, Gerald J.; Gehring, Stephan; Laperle, Christopher M.; Wands, Jack

    2009-01-01

    The high resolution characteristic of in-line x-ray phase contrast imaging can be used in conjunction with directed ultrasound to detect small displacements in soft tissue generated by differential acoustic radiation pressure. The imaging method is based on subtraction of two x-ray images, the first image taken with, and the second taken without the presence of ultrasound. The subtraction enhances phase contrast features and, to a large extent, removes absorption contrast so that differential movement of tissues with different acoustic impedances or relative ultrasonic absorption is highlighted in the image. Interfacial features of objects with differing densities are delineated in the image as a result of both the displacement introduced by the ultrasound and the inherent sensitivity of x-ray phase contrast imaging to density variations. Experiments with ex vivo murine tumors and human tumor phantoms point out a diagnostic capability of the method for identifying tumors.

  13. Skeletal MR imaging: Correlation with skeletal scintigraphy

    International Nuclear Information System (INIS)

    Colletti, P.M.; Raval, J.K.; Ford, P.V.; Benson, R.C.; Kerr, R.M.; Boswell, W.D.; Siegel, M.E.; Ralls, P.W.

    1987-01-01

    Skeletal MR images bone marrow while skeletal scintigraphy uses bone metabolism to demonstrate abnormalities. The purpose of this paper is to correlate these MR and scintigraphic findings. T1 and T2 MR images at 0.5 T were correlated with planar bone scintigraphy (RN) using Tc-99m MDP in 56 patients. Of 23 cases with suspected spinal metastases, 19 were positive by MR imaging, 16 by RN. Individual lesions were shown better by MR imaging in five and by RN in two. These two cases had scoliosis, a potential difficulty with MR imaging. In 14 cases of suspected avascular necrosis (AVN), MR imaging was positive in 13 while RN was positive in ten. One negative case by RN had bilateral AVN by MR imaging. Four skull lesions shown easily by RN were seen only in retrospect on MR images. MR imaging is advantageous in evaluating bones with predominant marrow such as vertebrae or the femoral head, while RN is superior in areas primarily composed of cortical bone such as the skull

  14. Differential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kwon-Ha; Ryu, Jong-Hyun; Jung, Chang-Won [Wonkwang University School of Medicine, Iksan (Korea, Republic of); Ryu, Cheol-Woo; Kim, Young-Jo; Kwon, Young-Man [Jeonbuk Technopark, Iksan (Korea, Republic of); Park, Mi-Ran; Cho, Seung-Ryong [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Chon, Kwon-Su [Catholic University of Daegu, Gyeongsan (Korea, Republic of)

    2014-12-15

    X-ray phase-contrast imaging can provide images with much greater soft-tissue contrast than conventional absorption-based images. In this paper, we describe differential X-ray phase-contrast images of insect specimens that were obtained using a grating-based Talbot interferometer and a laboratory X-ray source with a spot size of a few tens of micrometers. We developed the interferometer on the basis of the wavelength, periods, and height of the gratings; the field of view depends on the size of the grating, considering the refractive index of the specimen. The phase-contrast images were acquired using phase-stepping methods. The phase contrast imaging provided a significantly enhanced soft-tissue contrast compared with the attenuation data. The contour of the sample was clearly visible because the refraction from the edges of the object was strong in the differential phase-contrast image. Our results demonstrate that a grating-based Talbot interferometer with a conventional X-ray tube may be attractive as an X-ray imaging system for generating phase images. X-ray phase imaging obviously has sufficient potential and is expected to soon be a great tool for medical diagnostics.

  15. Differential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube

    International Nuclear Information System (INIS)

    Yoon, Kwon-Ha; Ryu, Jong-Hyun; Jung, Chang-Won; Ryu, Cheol-Woo; Kim, Young-Jo; Kwon, Young-Man; Park, Mi-Ran; Cho, Seung-Ryong; Chon, Kwon-Su

    2014-01-01

    X-ray phase-contrast imaging can provide images with much greater soft-tissue contrast than conventional absorption-based images. In this paper, we describe differential X-ray phase-contrast images of insect specimens that were obtained using a grating-based Talbot interferometer and a laboratory X-ray source with a spot size of a few tens of micrometers. We developed the interferometer on the basis of the wavelength, periods, and height of the gratings; the field of view depends on the size of the grating, considering the refractive index of the specimen. The phase-contrast images were acquired using phase-stepping methods. The phase contrast imaging provided a significantly enhanced soft-tissue contrast compared with the attenuation data. The contour of the sample was clearly visible because the refraction from the edges of the object was strong in the differential phase-contrast image. Our results demonstrate that a grating-based Talbot interferometer with a conventional X-ray tube may be attractive as an X-ray imaging system for generating phase images. X-ray phase imaging obviously has sufficient potential and is expected to soon be a great tool for medical diagnostics

  16. Preliminary evaluation of cryogenic two-phase flow imaging using electrical capacitance tomography

    Science.gov (United States)

    Xie, Huangjun; Yu, Liu; Zhou, Rui; Qiu, Limin; Zhang, Xiaobin

    2017-09-01

    The potential application of the 2-D eight-electrode electrical capacitance tomography (ECT) to the inversion imaging of the liquid nitrogen-vaporous nitrogen (LN2-VN2) flow in the tube is theoretically evaluated. The phase distribution of the computational domain is obtained using the simultaneous iterative reconstruction technique with variable iterative step size. The detailed mathematical derivations for the calculations are presented. The calculated phase distribution for the two detached LN2 column case shows the comparable results with the water-air case, regardless of the much reduced dielectric permittivity of LN2 compared with water. The inversion images of total eight different LN2-VN2 flow patterns are presented and quantitatively evaluated by calculating the relative void fraction error and the correlation coefficient. The results demonstrate that the developed reconstruction technique for ECT has the capacity to reconstruct the phase distribution of the complex LN2-VN2 flow, while the accuracy of the inversion images is significantly influenced by the size of the discrete phase. The influence of the measurement noise on the image quality is also considered in the calculations.

  17. Precision mass measurements using the Phase-Imaging Ion-Cyclotron-Resonance detection technique

    CERN Document Server

    Karthein, Jonas

    This thesis presents the implementation and improvement of the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) detection technique at the ISOLTRAP experiment, located at the ISOLDE / CERN, with the purpose of on-line high-precision and high-resolution mass spectrometry. Extensive simulation studies were performed with the aim of improving the phase-imaging resolution and finding the optimal position for detector placement. Following the outcome of these simulations, the detector was moved out of a region of electric-field distortion and closer to the center of the Penning trap, showing a dramatic improvement in the quality and reproducibility of the phase-imaging measurements. A new image reconstitution and analysis software for the MCP-PS detector was written in Python and ROOT and introduced in the framework of PI-ICR mass measurements. The state of the art in the field of time-of-flight ion-cyclotron-resonance measurements is illustrated through an analysis of on-line measurements of the mirror nuclei $...

  18. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    International Nuclear Information System (INIS)

    Demi, Libertario; Van Sloun, Ruud J G; Wijkstra, Hessel; Mischi, Massimo

    2015-01-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization. (fast track communication)

  19. ISAR Imaging of Maneuvering Targets Based on the Modified Discrete Polynomial-Phase Transform

    Directory of Open Access Journals (Sweden)

    Yong Wang

    2015-09-01

    Full Text Available Inverse synthetic aperture radar (ISAR imaging of a maneuvering target is a challenging task in the field of radar signal processing. The azimuth echo can be characterized as a multi-component polynomial phase signal (PPS after the translational compensation, and the high quality ISAR images can be obtained by the parameters estimation of it combined with the Range-Instantaneous-Doppler (RID technique. In this paper, a novel parameters estimation algorithm of the multi-component PPS with order three (cubic phase signal-CPS based on the modified discrete polynomial-phase transform (MDPT is proposed, and the corresponding new ISAR imaging algorithm is presented consequently. This algorithm is efficient and accurate to generate a focused ISAR image, and the results of real data demonstrate the effectiveness of it.

  20. Optical phase plates as a creative medium for special effects in images

    Science.gov (United States)

    Shaoulov, Vesselin I.; Meyer, Catherine; Argotti, Yann; Rolland, Jannick P.

    2001-12-01

    A new paradigm and methods for special effects in images were recently proposed by artist and movie producer Steven Hylen. Based on these methods, images resembling painting may be formed using optical phase plates. The role of the mathematical and optical properties of the phase plates is studied in the development of these new art forms. Results of custom software as well as ASAP simulations are presented.

  1. Diagnostic accuracy of scintigraphic methods in the differential diagnosis of focal liver lesions

    International Nuclear Information System (INIS)

    Czermak, H.; Gomez, I.; Gallowitsch, H.J.; Lind, P.

    1993-01-01

    In a retrospective study of 160 patients who were examined within 12 months, we analysed the diagnosic value of scintigraphic techniques in the differential diagnosis of solid focal liver lesions. Haemangiomas were found in 77 patients. Bloodpool scintigraphy was true-positive in 66 (sensivitity 85%); for lesions greater than 2 cm in diameter, sensitivity increased to 94%. Metastases of CEA-expressing tumors were found in 42 patients, anti-CEA-immunoscintigraphy was true-positive in 33 patients (sensitivity 78.5%). Focal nodulary hyperplasia was found in 3 patients, adenomas in 6 patients. In the remaining 32 patiens we saw 4 hepatocellular carcinomas, 28 metastases from lung and breast cancer, 2 echinococcus cysts and 1 choledochus cyst. (orig.) [de

  2. Scintigraphic control of bone-fracture healing under ultrasonic stimulation: An animal experimental study

    International Nuclear Information System (INIS)

    Klug, W.; Franke, W.G.; Knoch, H.G.

    1986-01-01

    In a model of closed lower-leg fracture in rabbits and of secondary bone-fracture healing, scintigraphic control until biological healing was performed. Biological fracture healing was assumed for a region of interest (ROI)-activity ratio close to 1.0. After application of sup(99m)Tc-HEDP, 151 examinations were performed. ROI activity increased significantly until day 14 p.i. and reached the maximum value (Q=6.44) on day 14 postfracture. Sixty-one lower leg fractures were treated by ultrasound from days 14-28 postfractures. These stimulated fractures were biologically healed on day 168 postfracture. The fractures that were not treated by ultrasound could not be detected by scanning after day 203 postfracture. (orig.)

  3. Combined phase and X-Ray fluorescence imaging at the sub-cellular level

    International Nuclear Information System (INIS)

    Kosior, Ewelina

    2013-01-01

    This work presents some recent developments in the field of hard X-ray imaging applied to biomedical research. As the discipline is evolving quickly, new questions appear and the list of needs becomes bigger. Some of them are dealt with in this manuscript. It has been shown that the ID22NI beamline of the ESRF can serve as a proper experimental setup to investigate diverse aspects of cellular research. Together with its high spatial resolution, high flux and high energy range the experimental setup provides bigger field of view, is less sensitive to radiation damages (while taking phase contrast images) and suits well chemical analysis with emphasis on endogenous metals (Zn, Fe, Mn) but also with a possibility for exogenous one's like these found in nanoparticles (Au, Pt, Ag) study. Two synchrotron-based imaging techniques, fluorescence and phase contrast imaging were used in this research project. They were correlated with each other on a number of biological cases, from bacteria E.coli to various cells (HEK 293, PC12, MRC5VA, red blood cells). The explorations made in the chapter 5 allowed preparation of more established and detailed analysis, described in the next chapter where both techniques, X-ray fluorescence and phase contrast imaging, were exploited in order to access absolute metal projected mass fraction in a whole cell. The final image presents for the first time true quantitative information at the sub-cellular level, not biased by the cell thickness. Thus for the first time a fluorescence map serves as a complete quantitative image of a cell without any risk of misinterpretation. Once both maps are divided by each other pixel by pixel (fluorescence map divided by the phase map) they present a complete and final result of the metal (Zn in this work) projected mass fraction in ppm of dry weight. For the purpose of this calculation the analysis was extended to calibration (non-biological) samples. Polystyrene spheres of a known diameter and known

  4. Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy

    Science.gov (United States)

    Descloux, A.; Grußmayer, K. S.; Bostan, E.; Lukes, T.; Bouwens, A.; Sharipov, A.; Geissbuehler, S.; Mahul-Mellier, A.-L.; Lashuel, H. A.; Leutenegger, M.; Lasser, T.

    2018-03-01

    Super-resolution fluorescence microscopy provides unprecedented insight into cellular and subcellular structures. However, going `beyond the diffraction barrier' comes at a price, since most far-field super-resolution imaging techniques trade temporal for spatial super-resolution. We propose the combination of a novel label-free white light quantitative phase imaging with fluorescence to provide high-speed imaging and spatial super-resolution. The non-iterative phase retrieval relies on the acquisition of single images at each z-location and thus enables straightforward 3D phase imaging using a classical microscope. We realized multi-plane imaging using a customized prism for the simultaneous acquisition of eight planes. This allowed us to not only image live cells in 3D at up to 200 Hz, but also to integrate fluorescence super-resolution optical fluctuation imaging within the same optical instrument. The 4D microscope platform unifies the sensitivity and high temporal resolution of phase imaging with the specificity and high spatial resolution of fluorescence microscopy.

  5. Quantitative phase imaging using quadri-wave lateral shearing interferometry. Application to X-ray domain

    International Nuclear Information System (INIS)

    Rizzi, Julien

    2013-01-01

    Since Roentgen discovered X-rays, X-ray imaging systems are based on absorption contrast. This technique is inefficient for weakly absorbing objects. As a result, X-ray standard radiography can detect bones lesions, but cannot detect ligament lesions. However, phase contrast imaging can overcome this limitation. Since the years 2000, relying on former works of opticians, X-ray scientists are developing phase sensitive devices compatible with industrial applications such as medical imaging or non destructive control. Standard architectures for interferometry are challenging to implement in the X-ray domain. This is the reason why grating based interferometers became the most promising devices to envision industrial applications. They provided the first x-ray phase contrast images of living human samples. Nevertheless, actual grating based architectures require the use of at least two gratings, and are challenging to adapt on an industrial product. So, the aim of my thesis was to develop a single phase grating interferometer. I demonstrated that such a device can provide achromatic and propagation invariant interference patterns. I used this interferometer to perform quantitative phase contrast imaging of a biological fossil sample and x-ray at mirror metrology. (author)

  6. Spirometrically gated 133Xe ventilation imaging and phase analysis for assessment of regional lung function

    International Nuclear Information System (INIS)

    Inoue, Tomio

    1984-01-01

    The purpose of this study is to develop the technique of performing spirometrically gated 133 Xe ventilation imaging and to evaluate its clinical usefulness for the assessmentof regional ventilatory function in various lung diseases. Patients rebreathe d 133 Xe gas through the system with constant rates signaled by a metronom. The trigger signals from the patients were recorded in a minicomputer for 60 respiratory cycles simultaneously with posterior lung images. Functional images (phase analysis images) indicating phase and amplitude of regional ventilation were constructed by the first harmonic Fourier analysis. Materials included 13 normal volunteers and patients with COPD (24), lung cancer (5), pulmonary embolism (4) and others (20). In normal controls, phase analysis images before respiratory motion correction revealed gradual decrease in amplitude from base to apex with uniform phase distribution. The amplitude and phase distribution after respiratory motion correction became even more uniform. In patients with COPD, phase analysis images showed asymmetrical and irregular amplitude distribution with non-uniform phase distribution. The standard deviation (S.D.) of phase histogram correlated well with FEVsub(1.0)% (r=0.71, p<0.001) and down slope of flowvolume curve (r=0.55, p<0.001), and less prominently with %VC (r=0.42, p<0.01). Mean S.D. in patients with COPD (12.3+-6.5 degree, mean+-1 s.d.) was significantly larger than in normal controls (6.3+-1.5). Amplitude profile curve analysis revealed 83% sensitivity for the detection of abnormal spirometric respiratory function test. Data aquisition and processing of present method are rapid and easy to perform. The phase analysis of the gated ventilation images should prove useful in the clinical evaluation of patients with uneven ventilation such as COPD. (J.P.N.)

  7. Third order harmonic imaging for biological tissues using three phase-coded pulses.

    Science.gov (United States)

    Ma, Qingyu; Gong, Xiufen; Zhang, Dong

    2006-12-22

    Compared to the fundamental and the second harmonic imaging, the third harmonic imaging shows significant improvements in image quality due to the better resolution, but it is degraded by the lower sound pressure and signal-to-noise ratio (SNR). In this study, a phase-coded pulse technique is proposed to selectively enhance the sound pressure of the third harmonic by 9.5 dB whereas the fundamental and the second harmonic components are efficiently suppressed and SNR is also increased by 4.7 dB. Based on the solution of the KZK nonlinear equation, the axial and lateral beam profiles of harmonics radiated from a planar piston transducer were theoretically simulated and experimentally examined. Finally, the third harmonic images using this technique were performed for several biological tissues and compared with the images obtained by the fundamental and the second harmonic imaging. Results demonstrate that the phase-coded pulse technique yields a dramatically cleaner and sharper contrast image.

  8. Combined fluorescence and phase contrast imaging at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Hornberger, B.; Feser, M.; Jacobsen, C.; Vogt, S.; Legnini, D.; Paterson, D.; Rehak, P.; DeGeronimo, G.; Palmer, B.M.; Experimental Facilities Division; State Univ. of New York at Stony Brook Univ.; BNL; Univ. of Vermont

    2006-01-01

    X-ray fluorescence microprobes excel at detecting and quantifying trace metals in biological and environmental science samples, but typically do not detect low Z elements such as carbon and nitrogen. Therefore, it is hard to put the trace metals into context with their natural environment. We are implementing phase contrast capabilities with a segmented detector into several microprobes at the Advanced Photon Source (APS) to address this problem. Qualitative differential phase contrast images from a modified soft x-ray detector already provide very useful information for general users. We are also implementing a quantitative method to recover the absolute phase shift by Fourier filtering detector images. New detectors are under development which are optimized for the signal levels present at the APS. In this paper, we concentrate on fundamental signal to noise considerations comparing absorption and differential phase contrast

  9. Scintigraphic evaluation of Lyme disease: Gallium-67 imaging of Lyme myositis

    International Nuclear Information System (INIS)

    Kengen, R.A.; Linde, M. von der; Sprenger, H.G.; Piers, D.A.

    1989-01-01

    A patient suffering from Lyme disease had cardiac conduction abnormalities, symptoms of arthritis, and myalgia. A Ga-67 image showed evidence of endomyocarditis, but intense skeletal muscle uptake pointed to Lyme myositis. Reference is made to two other case reports of Lyme myositis

  10. X-ray phase contrast imaging of the bone-cartilage interface

    International Nuclear Information System (INIS)

    Ismail, Elna Che; Kaabar, W.; Garrity, D.; Gundogdu, O.; Bunk, O.; Pfeiffer, F.; Farquharson, M.J.; Bradley, D.A.

    2010-01-01

    Synovial joints articulate in a lubricating environment, the system providing for smooth articulation. The articular cartilage overlying the bone consists of a network of collagen fibres. This network is essential to cartilage integrity, suffering damage in degenerative joint disease such as osteoarthritis. At Surrey and also in work conducted by this group at the Paul Scherrer Institute (PSI) synchrotron site we have been applying a number of techniques to study the bone-cartilage interface and of changes occurring in this with disease. One of the techniques attracting particular interest is X-ray phase contrast imaging, yielding information on anatomical features that manifest from the large scale organisation of collagen and the mineralised phase contained within the collagen fibres in the deep cartilage zone. This work briefly reviews some of the basic supporting physics of X-ray phase contrast imaging and then shows example images of the articular surface and subchondral bone and other supporting results obtained to-date. Present results have been obtained on sections of bone not displaying evidence of an osteoarthritic lesion and can be used as a baseline against which diseased bone can be compared.

  11. X-ray phase contrast imaging of the bone-cartilage interface

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, Elna Che; Kaabar, W.; Garrity, D.; Gundogdu, O. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Bunk, O. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Pfeiffer, F. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Farquharson, M.J. [Department of Radiography, City University, London EC1V OHB (United Kingdom); Bradley, D.A. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom)], E-mail: d.a.bradley@surrey.ac.uk

    2010-04-15

    Synovial joints articulate in a lubricating environment, the system providing for smooth articulation. The articular cartilage overlying the bone consists of a network of collagen fibres. This network is essential to cartilage integrity, suffering damage in degenerative joint disease such as osteoarthritis. At Surrey and also in work conducted by this group at the Paul Scherrer Institute (PSI) synchrotron site we have been applying a number of techniques to study the bone-cartilage interface and of changes occurring in this with disease. One of the techniques attracting particular interest is X-ray phase contrast imaging, yielding information on anatomical features that manifest from the large scale organisation of collagen and the mineralised phase contained within the collagen fibres in the deep cartilage zone. This work briefly reviews some of the basic supporting physics of X-ray phase contrast imaging and then shows example images of the articular surface and subchondral bone and other supporting results obtained to-date. Present results have been obtained on sections of bone not displaying evidence of an osteoarthritic lesion and can be used as a baseline against which diseased bone can be compared.

  12. A new method for information retrieval in two-dimensional grating-based X-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wang Zhi-Li; Gao Kun; Chen Jian; Ge Xin; Tian Yang-Chao; Wu Zi-Yu; Zhu Pei-Ping

    2012-01-01

    Grating-based X-ray phase contrast imaging has been demonstrated to be an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse-projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensional phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method

  13. Scintigraphic calf perfusion symmetry after exercise and prediction of cardiovascular events: One stone to kill two birds?

    International Nuclear Information System (INIS)

    Tellier, Philippe; Lecouffe, Pascal; Zureik, Mahmoud

    2007-01-01

    Background: Peripheral arterial disease (PAD) is commonly associated with a high cardiovascular mortality and morbidity as a marker of plurifocal atherosclerosis. Whether exercise thallium perfusion muscular asymmetry in the legs associated with PAD has prognostic value is unknown. Such a hypothesis was evaluated in a prospective study which remains the gold standard in clinical research. Methods and results: Scintigraphic calf perfusion symmetry after exercise (SCPSE) was measured at the end of a maximal or symptom-limited treadmill exercise test in 358 patients with known or suspected coronary artery disease (CAD). During the follow-up period (mean 85.3±32.8 months), 93 cardiovascular events and deaths (incident cases) occurred. Among those incident cases, the percentage of subjects with higher SCPSE values (third tertile) was 45.2%, versus 29.1% in controls (lower tertiles) (p=0.005). In stepwise multivariate analysis performed with the Cox proportional hazards model, previous CAD and SCPSE were the only significant independent predictors of prognosis. The multivariate relative risk of cardiovascular death or event in subjects with higher values of SCPSE was 1.94 (95% CI: 1.15-3.21; p<0.01). Conclusions: Scintigraphic calf perfusion asymmetry after exercise was independently associated with incident cardiovascular events in high-risk subjects. This index, which is easily and quickly calculated, could be used for evaluation of cardiovascular risk

  14. Scintigraphic calf perfusion symmetry after exercise and prediction of cardiovascular events: One stone to kill two birds?

    Science.gov (United States)

    Tellier, Philippe; Lecouffe, Pascal; Zureik, Mahmoud

    2007-02-01

    BackgroundPeripheral arterial disease (PAD) is commonly associated with a high cardiovascular mortality and morbidity as a marker of plurifocal atherosclerosis. Whether exercise thallium perfusion muscular asymmetry in the legs associated with PAD has prognostic value is unknown. Such a hypothesis was evaluated in a prospective study which remains the gold standard in clinical research. Methods and resultsScintigraphic calf perfusion symmetry after exercise (SCPSE) was measured at the end of a maximal or symptom-limited treadmill exercise test in 358 patients with known or suspected coronary artery disease (CAD). During the follow-up period (mean 85.3±32.8 months), 93 cardiovascular events and deaths (incident cases) occurred. Among those incident cases, the percentage of subjects with higher SCPSE values (third tertile) was 45.2%, versus 29.1% in controls (lower tertiles) ( p=0.005). In stepwise multivariate analysis performed with the Cox proportional hazards model, previous CAD and SCPSE were the only significant independent predictors of prognosis. The multivariate relative risk of cardiovascular death or event in subjects with higher values of SCPSE was 1.94 (95% CI: 1.15-3.21; p<0.01). ConclusionsScintigraphic calf perfusion asymmetry after exercise was independently associated with incident cardiovascular events in high-risk subjects. This index, which is easily and quickly calculated, could be used for evaluation of cardiovascular risk.

  15. Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source

    International Nuclear Information System (INIS)

    Donath, Tilman; Bunk, Oliver; Groot, Waldemar; Bednarzik, Martin; Gruenzweig, Christian; David, Christian; Pfeiffer, Franz; Hempel, Eckhard; Popescu, Stefan; Hoheisel, Martin

    2009-01-01

    Phase-contrast imaging at laboratory-based x-ray sources using grating interferometers has been developed over the last few years for x-ray energies of up to 28 keV. Here, we show first phase-contrast projection and tomographic images recorded at significantly higher x-ray energies, produced by an x-ray tube source operated at 100 kV acceleration voltage. We find our measured tomographic phase images in good agreement with tabulated data. The extension of phase-contrast imaging to this significantly higher x-ray energy opens up many applications of the technique in medicine and industrial nondestructive testing.

  16. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, Saravanan [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Kalra, Mannudeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Waldrop, Sandra M. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Mittal, Pardeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Small, William C. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States)]. E-mail: wsmall@emory.edu

    2006-09-15

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  17. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    International Nuclear Information System (INIS)

    Namasivayam, Saravanan; Kalra, Mannudeep K.; Waldrop, Sandra M.; Mittal, Pardeep K.; Small, William C.

    2006-01-01

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  18. OctreoScan 111 for imaging of a somatostatin receptor-positive islet cell tumor in rat

    International Nuclear Information System (INIS)

    Bruns, C.; Stolz, B.; Albert, R.; Marbach, P.; Pless, J.

    1993-01-01

    We report here the in vitro characterization of SDZ 215-811 and the in vivo imaging of a islet cell tumor gown in rats using [ 111 In]SDZ 215-811. In vitro autoradiographies revelaed a high density of SRIF receptors on the pancreatic tumor tissue. As early as 5 min after intravenous injection of [ 111 In]SDZ 215-811 into tumour-bearing rats, the tumors were clearly localized by gamma-camera scintigraphy. Even 24 h post injection, the islet cell tumor was still detectable. The radioligand was mainly cleared from the circulation via the Kidneys, with a rapid α-phase (t 1/2 =5.6 min) and a slow elimination phase (t 1/2 =7.3 h). Biodistribution studies revealed a relatively high accumulation of radioactivity in the kidneys, but low uptake into the liver and the intestine. High uptake of [ 111 In]SDZ 215-811 was observed for the tumor tissue (0.92±0.07% ID/g; 1 h post injection). Interestingly, a tumor load of 0.14±0.01% ID/g was still measured after 24 h. The tumor/blood ratio was 4.93 after 24 h, indicating specific accumulation of radioactivity in the islet cell tumour. [ 111 In]SDZ 215-811 appears to be sensitive and specific ligand for SRIF receptorpositive tumors and offers an easy procedure for scintigraphic imaging of such tumors in man. (orig.)

  19. Hybrid phase retrieval algorithm for solving the twin image problem in in-line digital holography

    Science.gov (United States)

    Zhao, Jie; Wang, Dayong; Zhang, Fucai; Wang, Yunxin

    2010-10-01

    For the reconstruction in the in-line digital holography, there are three terms overlapping with each other on the image plane, named the zero order term, the real image and the twin image respectively. The unwanted twin image degrades the real image seriously. A hybrid phase retrieval algorithm is presented to address this problem, which combines the advantages of two popular phase retrieval algorithms. One is the improved version of the universal iterative algorithm (UIA), called the phase flipping-based UIA (PFB-UIA). The key point of this algorithm is to flip the phase of the object iteratively. It is proved that the PFB-UIA is able to find the support of the complicated object. Another one is the Fienup algorithm, which is a kind of well-developed algorithm and uses the support of the object as the constraint among the iteration procedure. Thus, by following the Fienup algorithm immediately after the PFB-UIA, it is possible to produce the amplitude and the phase distributions of the object with high fidelity. The primary simulated results showed that the proposed algorithm is powerful for solving the twin image problem in the in-line digital holography.

  20. Phase modulation due to crystal diffraction by ptychographic imaging

    Science.gov (United States)

    Civita, M.; Diaz, A.; Bean, R. J.; Shabalin, A. G.; Gorobtsov, O. Yu.; Vartanyants, I. A.; Robinson, I. K.

    2018-03-01

    Solving the phase problem in x-ray crystallography has occupied a considerable scientific effort in the 20th century and led to great advances in structural science. Here we use x-ray ptychography to demonstrate an interference method which measures the phase of the beam transmitted through a crystal, relative to the incoming beam, when diffraction takes place. The observed phase change of the direct beam through a small gold crystal is found to agree with both a quasikinematical model and full dynamical theories of diffraction. Our discovery of a diffraction contrast mechanism will enhance the interpretation of data obtained from crystalline samples using the ptychography method, which provides some of the most accurate x-ray phase-contrast images.

  1. Correlation of early-phase {sup 18}F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); Huang, Chin-Chang; Hsu, Wen-Chun [Chang Gung Memorial Hospital, Department of Neurology, Taipei (China); Yen, Tzu-Chen [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Kung, Mei-Ping [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States)

    2012-04-15

    {sup 18}F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R{sub 1}) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R{sub 1} images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R{sub 1} and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R{sub 1} images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R{sub 1}. A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R{sub 1} and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  2. Wide-field phase imaging for the endoscopic detection of dysplasia and early-stage esophageal cancer

    Science.gov (United States)

    Fitzpatrick, C. R. M.; Gordon, G. S. D.; Sawyer, T. W.; Wilkinson, T. D.; Bohndiek, S. E.

    2018-02-01

    Esophageal cancer has a 5-year survival rate below 20%, but can be curatively resected if it is detected early. At present, poor contrast for early lesions in white light imaging leads to a high miss rate in standard-of- care endoscopic surveillance. Early lesions in the esophagus, referred to as dysplasia, are characterized by an abundance of abnormal cells with enlarged nuclei. This tissue has a different refractive index profile to healthy tissue, which results in different light scattering properties and provides a source of endogenous contrast that can be exploited for advanced endoscopic imaging. For example, point measurements of such contrast can be made with scattering spectroscopy, while optical coherence tomography generates volumetric data. However, both require specialist interpretation for diagnostic decision making. We propose combining wide-field phase imaging with existing white light endoscopy in order to provide enhanced contrast for dysplasia and early-stage cancer in an image format that is familiar to endoscopists. Wide-field phase imaging in endoscopy can be achieved using coherent illumination combined with phase retrieval algorithms. Here, we present the design and simulation of a benchtop phase imaging system that is compatible with capsule endoscopy. We have undertaken preliminary optical modelling of the phase imaging setup, including aberration correction simulations and an investigation into distinguishing between different tissue phantom scattering coefficients. As our approach is based on phase retrieval rather than interferometry, it is feasible to realize a device with low-cost components for future clinical implementation.

  3. Condensed images for evaluating gastric motility patterns

    Energy Technology Data Exchange (ETDEWEB)

    Tatsch, K.; Schroettle, W.; Kirsch, C.-M. (Munich Univ. (Germany, F.R.). Dept. of Radiology)

    1991-04-01

    A condensed imaging technique was applied to gastric emptying studies to investigate (a) whether different types of motility disorders may be distinguished by characteristic image patterns and (b) whether the findings obtained provide additional information compared to standard quantitative measurements. Condensed images and quantitative data of gastric emptying were evaluated in 75 consecutive patients with normal function and various disorders such as peptic ulcer, postvagotomy, pyloric obstruction, dumping syndrome, gastoparesis etc. Condensed images were generated from a gastric region of interest. They display the distribution and behaviour of a radioactive test meal in a space-time matrix, whose horizontal and vertical dimensions are temporal and spatial, respectively. As shown in a series of representative examples condensed images disclose a variety of well-defined image patterns reflecting different pathophysiological mechanisms. This qualitative characterization of gastric emptying patterns provided in 34 of the 75 patients (45%) important new information compared to quantitative data. The application of condensed imaging techniques to gastric emptying studies (complementary to quantitative measurements) may, therefore, enhance the diagnostic value of scintigraphic techniques. (author).

  4. Drive frequency dependent phase imaging in piezoresponse force microscopy

    International Nuclear Information System (INIS)

    Bo Huifeng; Kan Yi; Lu Xiaomei; Liu Yunfei; Peng Song; Wang Xiaofei; Cai Wei; Xue Ruoshi; Zhu Jinsong

    2010-01-01

    The drive frequency dependent piezoresponse (PR) phase signal in near-stoichiometric lithium niobate crystals is studied by piezoresponse force microscopy. It is clearly shown that the local and nonlocal electrostatic forces have a great contribution to the PR phase signal. The significant PR phase difference of the antiparallel domains are observed at the contact resonances, which is related to the electrostatic dominated electromechanical interactions of the cantilever and tip-sample system. Moreover, the modulation voltage induced frequency shift at higher eigenmodes could be attributed to the change of indention force depending on the modulation amplitude with a piezoelectric origin. The PR phase of the silicon wafer is also measured for comparison. It is certificated that the electrostatic interactions are universal in voltage modulated scanning probe microscopy and could be extended to other phase imaging techniques.

  5. In-line phase-contrast stereoscopic X-ray imaging for radiological purposes: An initial experimental study

    International Nuclear Information System (INIS)

    Siegbahn, E.A.; Coan, P.; Zhou, S.-A.; Bravin, A.; Brahme, A.

    2011-01-01

    We report results from a pilot study in which the in-line propagation-based phase-contrast imaging technique is combined with the stereoscopic method. Two phantoms were imaged at several sample-detector distances using monochromatic, 30 keV, X-rays. High contrast- and spatial-resolution phase-contrast stereoscopic pairs of X-ray images were constructed using the anaglyph approach and a vivid stereoscopic effect was demonstrated. On the other hand, images of the same phantoms obtained with a shorter sample-to-detector distance, but otherwise the same experimental conditions (i.e. the same X-ray energy and absorbed radiation dose), corresponding to the conventional attenuation-based imaging mode, hardly revealed stereoscopic effects because of the lower image contrast produced. These results have confirmed our hypothesis that stereoscopic X-ray images of samples with objects composed of low-atomic-number elements are considerably improved if phase-contrast imaging is used. It is our belief that the high-resolution phase-contrast stereoscopic method will be a valuable new medical imaging tool for radiologists and that it will be of help to enhance the diagnostic capability in the examination of patients in future clinical practice, even though further efforts will be needed to optimize the system performance.

  6. Phase Retrieval Using a Genetic Algorithm on the Systematic Image-Based Optical Alignment Testbed

    Science.gov (United States)

    Taylor, Jaime R.

    2003-01-01

    NASA s Marshall Space Flight Center s Systematic Image-Based Optical Alignment (SIBOA) Testbed was developed to test phase retrieval algorithms and hardware techniques. Individuals working with the facility developed the idea of implementing phase retrieval by breaking the determination of the tip/tilt of each mirror apart from the piston motion (or translation) of each mirror. Presented in this report is an algorithm that determines the optimal phase correction associated only with the piston motion of the mirrors. A description of the Phase Retrieval problem is first presented. The Systematic Image-Based Optical Alignment (SIBOA) Testbeb is then described. A Discrete Fourier Transform (DFT) is necessary to transfer the incoming wavefront (or estimate of phase error) into the spatial frequency domain to compare it with the image. A method for reducing the DFT to seven scalar/matrix multiplications is presented. A genetic algorithm is then used to search for the phase error. The results of this new algorithm on a test problem are presented.

  7. In-phase and out-of-phase gradient-echo imaging in abdominal studies: intra-individual comparison of three different techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ramalho, Miguel; Heredia, Vasco; Campos, Rafael O. P. de; Azevedo, Rafael M.; Semelka, Richard C. (Dept. of Radiology, Univ. of North Carolina at Chapel Hill (United States)); Dale, Brian M. (Siemens Medical Systems, Morrisville (United States)), email: richsem@med.unc.edu

    2012-05-15

    Background: T1-weighted gradient-echo in-phase and out-of-phase imaging is an essential component of comprehensive abdominal MR exams. It is useful for the study of fat-containing lesions and to identify various disease states related to the presence of fat in the liver. Purpose: To compare three T1-weighted in-phase and out-of-phase (IP/OP) gradient-echo imaging sequences in an intra-individual fashion, and to determine whether advantages exist for each of these sequences for various patient types. Material and Methods: One hundred and eighteen consecutive subjects (74 men, 44 women; mean age 53.9 +- 13.8 years) who had MRI examinations containing all three different IP/OP sequences (two-dimensional spoiled gradient-echo [2D-GRE], three-dimensional gradient-echo [3D-GRE], and magnetization-prepared gradient-recall echo [MP-GRE]) were included. Two different reviewers independently and blindly qualitatively evaluated IP/OP sequences to determine image quality, extent of artifacts, lesion detectability and conspicuity, and subjective grading of liver steatosis for the various sequences. Quantitative analysis was also performed. Qualitative and quantitative data were subjected to statistical analysis. Results: Respiratory ghosting, parallel imaging, and truncation artifacts as well as shading and blurring were more pronounced with 3D-GRE IP/OP imaging. Overall image quality was higher with 2D-GRE (P < 0.05). Detectability of low-fluid content lesions was lower with IP/OP MP-GRE sequences. MP-GRE sequences had the lowest SNRs (P < 0.001). Liver-to-spleen and liver-to-lesion CNRs were significantly lower with 3D-GRE and MP-GR, respectively (P < 0.001). Fat liver indexes showed strongly positive correlation between all sequences. Conclusion: Currently, 2D-GRE remains the best approach for clinical IP/OP imaging. The good image quality of MP-GRE sequences acquired in a free-breathing manner should recommend its use in patients unable to suspend breathing

  8. In-phase and out-of-phase gradient-echo imaging in abdominal studies: intra-individual comparison of three different techniques

    International Nuclear Information System (INIS)

    Ramalho, Miguel; Heredia, Vasco; Campos, Rafael O. P. de; Azevedo, Rafael M.; Semelka, Richard C.; Dale, Brian M.

    2012-01-01

    Background: T1-weighted gradient-echo in-phase and out-of-phase imaging is an essential component of comprehensive abdominal MR exams. It is useful for the study of fat-containing lesions and to identify various disease states related to the presence of fat in the liver. Purpose: To compare three T1-weighted in-phase and out-of-phase (IP/OP) gradient-echo imaging sequences in an intra-individual fashion, and to determine whether advantages exist for each of these sequences for various patient types. Material and Methods: One hundred and eighteen consecutive subjects (74 men, 44 women; mean age 53.9 ± 13.8 years) who had MRI examinations containing all three different IP/OP sequences (two-dimensional spoiled gradient-echo [2D-GRE], three-dimensional gradient-echo [3D-GRE], and magnetization-prepared gradient-recall echo [MP-GRE]) were included. Two different reviewers independently and blindly qualitatively evaluated IP/OP sequences to determine image quality, extent of artifacts, lesion detectability and conspicuity, and subjective grading of liver steatosis for the various sequences. Quantitative analysis was also performed. Qualitative and quantitative data were subjected to statistical analysis. Results: Respiratory ghosting, parallel imaging, and truncation artifacts as well as shading and blurring were more pronounced with 3D-GRE IP/OP imaging. Overall image quality was higher with 2D-GRE (P < 0.05). Detectability of low-fluid content lesions was lower with IP/OP MP-GRE sequences. MP-GRE sequences had the lowest SNRs (P < 0.001). Liver-to-spleen and liver-to-lesion CNRs were significantly lower with 3D-GRE and MP-GR, respectively (P < 0.001). Fat liver indexes showed strongly positive correlation between all sequences. Conclusion: Currently, 2D-GRE remains the best approach for clinical IP/OP imaging. The good image quality of MP-GRE sequences acquired in a free-breathing manner should recommend its use in patients unable to suspend breathing

  9. Phase contrast X-ray imaging at the bone-cartilage interface

    International Nuclear Information System (INIS)

    Che Ismail, E.; Gundogdu, O.; Bradley, D.A.

    2008-01-01

    Full text: Phase contrast X-ray imaging is a simple technique to investigate various biological samples. At Surrey, the bone-cartilage interface is one of the biological samples which actively been studied. Bone-cartilage interface study gives a particular interest in this research as the degeneration of cartilage is the hallmark of the degenerative joint disease such as osteoarthritis. We have been applying the phase contrast imaging technique in studying the bone-cartilage interface, obtaining information on anatomical features such as the cartilage, blood vessel, tide mark and cement line. Our samples range from dry bone-cartilage to wet bone-cartilage tissue. This work will briefly review the basic supporting physics of the study. It also shows some of the images and other results that we have obtained to-date. Fig. 1 shows examples obtained using the X-ray tube system at the University of Surrey

  10. Cervical SPECT Camera for Parathyroid Imaging

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-08-31

    Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

  11. Binocular contrast-gain control for natural scenes: Image structure and phase alignment.

    Science.gov (United States)

    Huang, Pi-Chun; Dai, Yu-Ming

    2018-05-01

    In the context of natural scenes, we applied the pattern-masking paradigm to investigate how image structure and phase alignment affect contrast-gain control in binocular vision. We measured the discrimination thresholds of bandpass-filtered natural-scene images (targets) under various types of pedestals. Our first experiment had four pedestal types: bandpass-filtered pedestals, unfiltered pedestals, notch-filtered pedestals (which enabled removal of the spatial frequency), and misaligned pedestals (which involved rotation of unfiltered pedestals). Our second experiment featured six types of pedestals: bandpass-filtered, unfiltered, and notch-filtered pedestals, and the corresponding phase-scrambled pedestals. The thresholds were compared for monocular, binocular, and dichoptic viewing configurations. The bandpass-filtered pedestal and unfiltered pedestals showed classic dipper shapes; the dipper shapes of the notch-filtered, misaligned, and phase-scrambled pedestals were weak. We adopted a two-stage binocular contrast-gain control model to describe our results. We deduced that the phase-alignment information influenced the contrast-gain control mechanism before the binocular summation stage and that the phase-alignment information and structural misalignment information caused relatively strong divisive inhibition in the monocular and interocular suppression stages. When the pedestals were phase-scrambled, the elimination of the interocular suppression processing was the most convincing explanation of the results. Thus, our results indicated that both phase-alignment information and similar image structures cause strong interocular suppression. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. A Theoretical and Experimental Study of the Subtraction of Two Scintigraphic Images - As Applied to Visualization of the Pancreas; Etude Theorique et Experimentale de la Soustraction de Deux Images Scintigraphiques

    Energy Technology Data Exchange (ETDEWEB)

    Desgrez, A.; Razafindramamba, V.; Saint-Laurent, J. de; Kellershohn, C. [CEA, Service Hospitalier Frederic Joliot, Orsay (France)

    1969-05-15

    Some scintigraphic studies are limited because the tissue being depicted is not selective with respect to the radioactive product available. For example, the radioactivity of the circulating blood interferes with mercury scanning of bucco-pharyngeal tumours. Scintigraphy of the pancreas is likewise impeded by localization of selenomethionine in the liver. Similarly, certain types of liver incorporation impair the visualization of insufficiency in the right kidney. One solution to this problem is to use two different labelled compounds to produce two images and then subtract one from the other so as to separate out the tissue to be depicted. The paper deals with the various problems involved in such subtraction. For example, exact spatial coincidence ofthedata to be subtracted can be ensured only by simultaneous recording of the two images; aconsecutive recording, even if it is fast, may be detrimental. The operation often consists in a double technique: suppression of the unwanted tissue by subtraction and amplification of the contrast between the tissue under investigation and residual background noise. These two operations, subtraction and amplification, relate to variable magnitudes; the resolution of the final image is thus a function of certain statistical parameters, which are also discussed. In studies carried out on the pancreas, attention is paid to the respective advantages and conditions of spectrometric separation of the various products which can be used for subtraction; the value of labelled rose bengal, which can also be used for eliminating certain intestinal loops, is stressed. A description is given of two types of apparatus which can be used in making the subtraction. The first and cheaper device involves storing the data obtained on four-track magnetic tape; the second and more rapid method utilizes the memory of a 4096-channel analyser. With both of these devices it is possible to make several subtractions during a single examination and the

  13. Three-dimensional real-time synthetic aperture imaging using a rotating phased array transducer

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Dufait, Remi; Schoisswohl, Armin

    2002-01-01

    phased array, which is rotated over the volume of interest. The data is acquired using coded signals and synthetic transmit aperture imaging. Only one group of elements transmits at a time. The delays are set such as to form a cylindrical wave. The back-scattered signal carries information not only from......Current 3D real-time imaging is done either with sparse 2D arrays, or with mechanically moved phased arrays. The former results in a poor resolution and contrast due to a limited amount of elements. The latter has the disadvantage of low frame rates due to the sequential acquisition of the volume...... line-by-line and plane-by-plane. This paper describes an approach which combines mechanically moved phased array with synthetic transmit aperture imaging, resulting in high volume acquisition rates without a trade-off in image quality. The scan method uses a conventional fully populated 64 element...

  14. Abnormal I-123 HIPDM images in various disease entities

    International Nuclear Information System (INIS)

    Shih, W.J.; Magoun, S.; Coupal, J.J.; Clark, D.B.; Dekosky, S.T.; Kung, H.F.; Beihn, R.; Ryo, U.Y.

    1987-01-01

    Eighty patients who were referred from neurology service for evaluation of stroke, Alzheimer disease (AD), and/or other neurologic diseases underwent the study. Four views of planar images were obtained following the intravenous injection of 3-5 mCi of I-123 HIPDM. SPECT images were then obtained using a camera interfaced to a PDP-11 computer. Forty of the 80 patients had scintigraphic findings of stroke, which correlated well with head CT/cerebral angiogram. Sixteen patients with AD had good correlation between the degree of temporoparietal abnormality in the images. Severe AD and severe stroke patients almost always had a positive planar image. Normal I-123 HIPDM localization in the brain requires intact cerebral flow and cerebral neuronal function. A focal area of decreased I-123 HIPDM localization may represent either interruption of blood flow or neurochemical dysfunction

  15. Measurements and simulations analysing the noise behaviour of grating-based X-ray phase-contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Weber, T., E-mail: thomas.weber@physik.uni-erlangen.de [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany); Bartl, P.; Durst, J. [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany); Haas, W. [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany); University of Erlangen-Nuremberg, Pattern Recognition Lab, Martensstr. 3, 91058 Erlangen (Germany); Michel, T.; Ritter, A.; Anton, G. [University of Erlangen-Nuremberg, ECAP - Erlangen Center for Astroparticle Physics, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany)

    2011-08-21

    In the last decades, phase-contrast imaging using a Talbot-Lau grating interferometer is possible even with a low-brilliance X-ray source. With the potential of increasing the soft-tissue contrast, this method is on its way into medical imaging. For this purpose, the knowledge of the underlying physics of this technique is necessary. With this paper, we would like to contribute to the understanding of grating-based phase-contrast imaging by presenting results on measurements and simulations regarding the noise behaviour of the differential phases. These measurements were done using a microfocus X-ray tube with a hybrid, photon-counting, semiconductor Medipix2 detector. The additional simulations were performed by our in-house developed phase-contrast simulation tool 'SPHINX', combining both wave and particle contributions of the simulated photons. The results obtained by both of these methods show the same behaviour. Increasing the number of photons leads to a linear decrease of the standard deviation of the phase. The number of used phase steps has no influence on the standard deviation, if the total number of photons is held constant. Furthermore, the probability density function (pdf) of the reconstructed differential phases was analysed. It turned out that the so-called von Mises distribution is the physically correct pdf, which was also confirmed by measurements. This information advances the understanding of grating-based phase-contrast imaging and can be used to improve image quality.

  16. Frequency-domain imaging algorithm for ultrasonic testing by application of matrix phased arrays

    Directory of Open Access Journals (Sweden)

    Dolmatov Dmitry

    2017-01-01

    Full Text Available Constantly increasing demand for high-performance materials and systems in aerospace industry requires advanced methods of nondestructive testing. One of the most promising methods is ultrasonic imaging by using matrix phased arrays. This technique allows to create three-dimensional ultrasonic imaging with high lateral resolution. Further progress in matrix phased array ultrasonic testing is determined by the development of fast imaging algorithms. In this article imaging algorithm based on frequency domain calculations is proposed. This approach is computationally efficient in comparison with time domain algorithms. Performance of the proposed algorithm was tested via computer simulations for planar specimen with flat bottom holes.

  17. Two-level image authentication by two-step phase-shifting interferometry and compressive sensing

    Science.gov (United States)

    Zhang, Xue; Meng, Xiangfeng; Yin, Yongkai; Yang, Xiulun; Wang, Yurong; Li, Xianye; Peng, Xiang; He, Wenqi; Dong, Guoyan; Chen, Hongyi

    2018-01-01

    A two-level image authentication method is proposed; the method is based on two-step phase-shifting interferometry, double random phase encoding, and compressive sensing (CS) theory, by which the certification image can be encoded into two interferograms. Through discrete wavelet transform (DWT), sparseness processing, Arnold transform, and data compression, two compressed signals can be generated and delivered to two different participants of the authentication system. Only the participant who possesses the first compressed signal attempts to pass the low-level authentication. The application of Orthogonal Match Pursuit CS algorithm reconstruction, inverse Arnold transform, inverse DWT, two-step phase-shifting wavefront reconstruction, and inverse Fresnel transform can result in the output of a remarkable peak in the central location of the nonlinear correlation coefficient distributions of the recovered image and the standard certification image. Then, the other participant, who possesses the second compressed signal, is authorized to carry out the high-level authentication. Therefore, both compressed signals are collected to reconstruct the original meaningful certification image with a high correlation coefficient. Theoretical analysis and numerical simulations verify the feasibility of the proposed method.

  18. Spectro-refractometry of individual microscopic objects using swept-source quantitative phase imaging.

    Science.gov (United States)

    Jung, Jae-Hwang; Jang, Jaeduck; Park, Yongkeun

    2013-11-05

    We present a novel spectroscopic quantitative phase imaging technique with a wavelength swept-source, referred to as swept-source diffraction phase microscopy (ssDPM), for quantifying the optical dispersion of microscopic individual samples. Employing the swept-source and the principle of common-path interferometry, ssDPM measures the multispectral full-field quantitative phase imaging and spectroscopic microrefractometry of transparent microscopic samples in the visible spectrum with a wavelength range of 450-750 nm and a spectral resolution of less than 8 nm. With unprecedented precision and sensitivity, we demonstrate the quantitative spectroscopic microrefractometry of individual polystyrene beads, 30% bovine serum albumin solution, and healthy human red blood cells.

  19. Imaging in tuberculosis of the skull and skull-base: case report

    International Nuclear Information System (INIS)

    Sencer, S.; Aydin, K.; Poyanli, A.; Minareci, O.; Sencer, A.; Hepguel, K.

    2003-01-01

    We report a 19-year-old girl, who presented with headache and tonic/clonic seizures. Imaging revealed a lytic parietal skull lesion with an adjacent epidural mass, masses in the right parietal lobe and a posterior skull-base mass. The diagnosis of tuberculosis was made after resection of the extradural mass and later verified with culture of Mycobacterium tuberculosis. The parenchymal and skull-base lesions resolved following antituberculous treatment. We present CT, scintigraphic, angiographic and MRI findings. (orig.)

  20. Parametric images evaluation of selected phases of the heart cycle with PET

    International Nuclear Information System (INIS)

    Just, U.; Will, E.; Beuthien Baumann, B.; Bredow, J.

    2002-01-01

    The standard evaluation of dynamic heart acquisitions with PET uses image data not corrected for heart wall movement. The evaluation of parametric data sets (Patlak Plot) was investigated for gated studies of selected heart phases (diastolic, systolic) and compared to the standard evaluation. Parametric images of selected heart phases have improved resolution. The values for metabolic rate are different for a ''normal'' and gated evaluation, up to 50% more for the systole compared to the normal one. (orig.)

  1. A user-friendly LabVIEW software platform for grating based X-ray phase-contrast imaging.

    Science.gov (United States)

    Wang, Shenghao; Han, Huajie; Gao, Kun; Wang, Zhili; Zhang, Can; Yang, Meng; Wu, Zhao; Wu, Ziyu

    2015-01-01

    X-ray phase-contrast imaging can provide greatly improved contrast over conventional absorption-based imaging for weakly absorbing samples, such as biological soft tissues and fibre composites. In this study, we introduced an easy and fast way to develop a user-friendly software platform dedicated to the new grating-based X-ray phase-contrast imaging setup at the National Synchrotron Radiation Laboratory of the University of Science and Technology of China. The control of 21 motorized stages, of a piezoelectric stage and of an X-ray tube are achieved with this software, it also covers image acquisition with a flat panel detector for automatic phase stepping scan. Moreover, a data post-processing module for signals retrieval and other custom features are in principle available. With a seamless integration of all the necessary functions in one software package, this platform greatly facilitate users' activities during experimental runs with this grating based X-ray phase contrast imaging setup.

  2. Distinction of heterogeneity on Au nanostructured surface based on phase contrast imaging of atomic force microscopy

    International Nuclear Information System (INIS)

    Jung, Mi; Choi, Jeong-Woo

    2010-01-01

    The discrimination of the heterogeneity of different materials on nanostructured surfaces has attracted a great deal of interest in biotechnology as well as nanotechnology. Phase imaging through tapping mode of atomic force microscopy (TMAFM) can be used to distinguish the heterogeneity on a nanostructured surface. Nanostructures were fabricated using anodic aluminum oxide (AAO). An 11-mercaptoundecanoic acid (11-MUA) layer adsorbed onto the Au nanodots through self-assembly to improve the bio-compatibility. The Au nanostructures that were modified with 11-MUA and the concave surfaces were investigated using the TMAFM phase images to compare the heterogeneous and homogeneous nanostructured surfaces. Although the topography and phase images were taken simultaneously, the images were different. Therefore, the contrast in the TMAFM phase images revealed the different compositional materials on the heterogeneous nanostructure surface.

  3. Synchrotron 4-dimensional imaging of two-phase flow through porous media.

    Science.gov (United States)

    Kim, F H; Penumadu, D; Patel, P; Xiao, X; Garboczi, E J; Moylan, S P; Donmez, M A

    2016-01-01

    Near real-time visualization of complex two-phase flow in a porous medium was demonstrated with dynamic 4-dimensional (4D) (3D + time) imaging at the 2-BM beam line of the Advanced Photon Source (APS) at Argonne National Laboratory. Advancing fluid fronts through tortuous flow paths and their interactions with sand grains were clearly captured, and formations of air bubbles and capillary bridges were visualized. The intense X-ray photon flux of the synchrotron facility made 4D imaging possible, capturing the dynamic evolution of both solid and fluid phases. Computed Tomography (CT) scans were collected every 12 s with a pixel size of 3.25 µm. The experiment was carried out to improve understanding of the physics associated with two-phase flow. The results provide a source of validation data for numerical simulation codes such as Lattice-Boltzmann, which are used to model multi-phase flow through porous media.

  4. Estimating Accurate Target Coordinates with Magnetic Resonance Images by Using Multiple Phase-Encoding Directions during Acquisition.

    Science.gov (United States)

    Kim, Minsoo; Jung, Na Young; Park, Chang Kyu; Chang, Won Seok; Jung, Hyun Ho; Chang, Jin Woo

    2018-06-01

    Stereotactic procedures are image guided, often using magnetic resonance (MR) images limited by image distortion, which may influence targets for stereotactic procedures. The aim of this work was to assess methods of identifying target coordinates for stereotactic procedures with MR in multiple phase-encoding directions. In 30 patients undergoing deep brain stimulation, we acquired 5 image sets: stereotactic brain computed tomography (CT), T2-weighted images (T2WI), and T1WI in both right-to-left (RL) and anterior-to-posterior (AP) phase-encoding directions. Using CT coordinates as a reference, we analyzed anterior commissure and posterior commissure coordinates to identify any distortion relating to phase-encoding direction. Compared with CT coordinates, RL-directed images had more positive x-axis values (0.51 mm in T1WI, 0.58 mm in T2WI). AP-directed images had more negative y-axis values (0.44 mm in T1WI, 0.59 mm in T2WI). We adopted 2 methods to predict CT coordinates with MR image sets: parallel translation and selective choice of axes according to phase-encoding direction. Both were equally effective at predicting CT coordinates using only MR; however, the latter may be easier to use in clinical settings. Acquiring MR in multiple phase-encoding directions and selecting axes according to the phase-encoding direction allows identification of more accurate coordinates for stereotactic procedures. © 2018 S. Karger AG, Basel.

  5. Scintigraphical analyses of pulmonary function in dogs

    International Nuclear Information System (INIS)

    Clercx, C.

    1988-01-01

    The main goal of this study was to develop a quantitative analysis from 99mTc aerosol inhalation/perfusion (I/P) lung scintigrams. In particular attention was focused on both the regional I/P distribution, concerning the ratio of the mean I and P values in several lung regions, as well as on the local (intraregional) distribution of I/P, under a wide range of circumstances. In Ch. 2, the method and reference material are described. The distribution of the inhalation-to-perfusion ratios (I/P) is studied in anesthetized healthy dogs, with emphasis on inter-regional distribution and intra-regional dispersion of the I/P ratio. Moreover, it provides an insight into canine pulmonary physiology, frequently transposed from human lung physiology, what is not always correct. Ch. 3 deals with the possible methodological and physiological influences on the interpretation of scintigraphical measurements, such as age, posture and breed. Investigation of the effects of age and breed was pursued using qualitative studies of canine lung surfactant. The actual knowledge in this field lets prospect veterinary clinical meaning in the future. Finally in Ch. 4, the diagnostic value of the measurements was examined in experimental models of important lung disorders with different pathophysiological features, such as lobar and sublobar airway obstruction, and lung embolism. It also permits the investigation of the relative contribution of different compensating mechanisms upon the ventilation-to-perfusion ratio, such as collateral ventilation and hypoxic vasoconstriction. 218 refs.; 31 figs.; 14 tabs

  6. Image/patient registration from (partial) projection data by the Fourier phase matching method

    International Nuclear Information System (INIS)

    Weiguo Lu; You, J.

    1999-01-01

    A technique for 2D or 3D image/patient registration, PFPM (projection based Fourier phase matching method), is proposed. This technique provides image/patient registration directly from sequential tomographic projection data. The method can also deal with image files by generating 2D Radon transforms slice by slice. The registration in projection space is done by calculating a Fourier invariant (FI) descriptor for each one-dimensional projection datum, and then registering the FI descriptor by the Fourier phase matching (FPM) method. The algorithm has been tested on both synthetic and experimental data. When dealing with translated, rotated and uniformly scaled 2D image registration, the performance of the PFPM method is comparable to that of the IFPM (image based Fourier phase matching) method in robustness, efficiency, insensitivity to the offset between images, and registration time. The advantages of the former are that subpixel resolution is feasible, and it is more insensitive to image noise due to the averaging effect of the projection acquisition. Furthermore, the PFPM method offers the ability to generalize to 3D image/patient registration and to register partial projection data. By applying patient registration directly from tomographic projection data, image reconstruction is not needed in the therapy set-up verification, thus reducing computational time and artefacts. In addition, real time registration is feasible. Registration from partial projection data meets the geometry and dose requirements in many application cases and makes dynamic set-up verification possible in tomotherapy. (author)

  7. Simple and fast spectral domain algorithm for quantitative phase imaging of living cells with digital holographic microscopy

    Science.gov (United States)

    Min, Junwei; Yao, Baoli; Ketelhut, Steffi; Kemper, Björn

    2017-02-01

    The modular combination of optical microscopes with digital holographic microscopy (DHM) has been proven to be a powerful tool for quantitative live cell imaging. The introduction of condenser and different microscope objectives (MO) simplifies the usage of the technique and makes it easier to measure different kinds of specimens with different magnifications. However, the high flexibility of illumination and imaging also causes variable phase aberrations that need to be eliminated for high resolution quantitative phase imaging. The existent phase aberrations compensation methods either require add additional elements into the reference arm or need specimen free reference areas or separate reference holograms to build up suitable digital phase masks. These inherent requirements make them unpractical for usage with highly variable illumination and imaging systems and prevent on-line monitoring of living cells. In this paper, we present a simple numerical method for phase aberration compensation based on the analysis of holograms in spatial frequency domain with capabilities for on-line quantitative phase imaging. From a single shot off-axis hologram, the whole phase aberration can be eliminated automatically without numerical fitting or pre-knowledge of the setup. The capabilities and robustness for quantitative phase imaging of living cancer cells are demonstrated.

  8. Optical image encryption using password key based on phase retrieval algorithm

    Science.gov (United States)

    Zhao, Tieyu; Ran, Qiwen; Yuan, Lin; Chi, Yingying; Ma, Jing

    2016-04-01

    A novel optical image encryption system is proposed using password key based on phase retrieval algorithm (PRA). In the encryption process, a shared image is taken as a symmetric key and the plaintext is encoded into the phase-only mask based on the iterative PRA. The linear relationship between the plaintext and ciphertext is broken using the password key, which can resist the known plaintext attack. The symmetric key and the retrieved phase are imported into the input plane and Fourier plane of 4f system during the decryption, respectively, so as to obtain the plaintext on the CCD. Finally, we analyse the key space of the password key, and the results show that the proposed scheme can resist a brute force attack due to the flexibility of the password key.

  9. Spirometrically gated /sup 133/Xe ventilation imaging and phase analysis for assessment of regional lung function

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Tomio (Kanto Teishin Hospital, Tokyo (Japan))

    1984-10-01

    The purpose of this study is to develop the technique of performing spirometrically gated /sup 133/Xe ventilation imaging and to evaluate its clinical usefulness for the assessment of regional ventilatory function in various lung diseases. Patients rebreathed /sup 133/Xe gas through the system with constant rates signaled by a metronome. The trigger signals from the patients were recorded in a minicomputer for 60 respiratory cycles simultaneously with posterior lung images. Functional images (phase analysis images) indicating phase and amplitude of regional ventilation were constructed by the first harmonic Fourier analysis. Materials included 13 normal volunteers and patients with COPD (24), lung cancer (5), pulmonary embolism (4) and others (20). In normal controls, phase analysis images before respiratory motion correction revealed gradual decrease in amplitude from base to apex with uniform phase distribution. The amplitude and phase distribution after respiratory motion correction became even more uniform. In patients with COPD, phase analysis images showed asymmetrical and irregular amplitude distribution with non-uniform phase distribution. The standard deviation (S.D.) of phase histogram correlated well with FEVsub(1.0)% (r=0.71, p < 0.001) and down slope of flow-volume curve (r=0.55, p < 0.001), and less prominently with %VC (r=0.42, p < 0.01). Mean S.D. in patients with COPD (12.3 +- 6.5 degree, mean+-1 s.d.) was significantly larger than in normal controls (6.3 +- 1.5). Amplitude profile curve analysis revealed 83% sensitivity for the detection of abnormal spirometric respiratory function test. Data aquisition and processing of present method are rapid and easy to perform. The phase analysis of the gated ventilation images should prove useful in the clinical evaluation of patients with uneven ventilation such as COPD.

  10. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  11. Scintigraphic and Endoscopic Evaluation of Radiation-induced Acute Gastrointestinal Syndrome in Micro-pig Model

    International Nuclear Information System (INIS)

    Lee, Seung-Sook; Kim, Kyung-Min; Kim, Jin; Jang, Won-Suk; Lee, Jung-Eun; Kim, Noo-Ri; Lee, Sun-Joo; Kim, Mi-Sook; Ji, Young-Hoon; Cheon, Gi-Jeong; Lim, Sang-Moo

    2007-01-01

    Micro-pig model can be served as a proper substitute for humans in studying acute radiation syndrome following radiation-exposure accidents, especially showing similar clinico-pathologic response of hematopoietic and gastrointestinal (GI) syndrome to human. Among acute GI syndrome induced by radiation, GI motility disturbance has not been studied, however, it would be important in a viewpoint of affecting infectious progression from GI tract. Here, we employed scintigraphy of GI transit time and sequential endoscopic examination and tissue sampling in micropigs followed by abdominal radiation exposure. The specific aims of this study are to evaluate objective evidence of GI motility disturbance by scintigraphic evaluation and to find corresponding clinicoapthologic changes in radiation-induced acute GI syndrome

  12. Classification of natural circulation two-phase flow patterns using fuzzy inference on image analysis

    International Nuclear Information System (INIS)

    Mesquita, R.N. de; Masotti, P.H.F.; Penha, R.M.L.; Andrade, D.A.; Sabundjian, G.; Torres, W.M.

    2012-01-01

    Highlights: ► A fuzzy classification system for two-phase flow instability patterns is developed. ► Flow patterns are classified based on images of natural circulation experiments. ► Fuzzy inference is optimized to use single grayscale profiles as input. - Abstract: Two-phase flow on natural circulation phenomenon has been an important theme on recent studies related to nuclear reactor designs. The accuracy of heat transfer estimation has been improved with new models that require precise prediction of pattern transitions of flow. In this work, visualization of natural circulation cycles is used to study two-phase flow patterns associated with phase transients and static instabilities of flow. A Fuzzy Flow-type Classification System (FFCS) was developed to classify these patterns based only on image extracted features. Image acquisition and temperature measurements were simultaneously done. Experiments in natural circulation facility were adjusted to generate a series of characteristic two-phase flow instability periodic cycles. The facility is composed of a loop of glass tubes, a heat source using electrical heaters, a cold source using a helicoidal heat exchanger, a visualization section and thermocouples positioned over different loop sections. The instability cyclic period is estimated based on temperature measurements associated with the detection of a flow transition image pattern. FFCS shows good results provided that adequate image acquisition parameters and pre-processing adjustments are used.

  13. {sup 99m}Tc-HYNIC-spermine for imaging polyamine transport system-positive tumours: preclinical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pesnel, Sabrina [Institut de Recherche Pierre Fabre, Centre de Recherche en Oncologie Experimentale, Toulouse (France); UPS TAAM - CIPA, CNRS, Orleans (France); Guminski, Yves; Imbert, Thierry [Institut de Recherche Pierre Fabre, Division de Chimie Medicinale III, Castres (France); Pillon, Arnaud; Guilbaud, Nicolas; Kruczynski, Anna; Bailly, Christian [Institut de Recherche Pierre Fabre, Centre de Recherche en Oncologie Experimentale, Toulouse (France); Lerondel, Stephanie [UPS TAAM - CIPA, CNRS, Orleans (France); Le Pape, Alain [UPS TAAM - CIPA, CNRS, Orleans (France); Universite Francois Rabelais, INSERM U618, Tours (France)

    2011-10-15

    F14512 exploiting the polyamine transport system (PTS) for tumour cell delivery has been described as a potent antitumour agent. The optimal use of this compound will require a probe to identify tumour cells expressing a highly active PTS that might be more sensitive to the treatment. The aim of this study was to design and characterize a scintigraphic probe to evaluate its uptake in cancer cells expressing the PTS. Three polyamines coupled to a hydrazinonicotinamide (HYNIC) moiety were synthesized and labelled with {sup 99m}Tc. Their radiochemical purity was determined by HPLC. The plasma stability of the {sup 99m}Tc-HYNIC-spermine probe and its capacity to accumulate into PTS-active cells were also evaluated. In vitro internalization was tested using murine melanoma B16/F10 cells and human lung carcinoma A549 cells. Biodistribution was determined in healthy mice and tumour uptake was studied in B16/F10 tumour-bearing mice. A HL-60-Luc human leukaemia model was used to confront single photon emission computed tomography (SPECT) images obtained with the {sup 99m}Tc-labelled probe with those obtained by bioluminescence. The {sup 99m}Tc-HYNIC-spermine probe was selected for its capacity to accumulate into PTS-active cells and its stability in plasma. In vitro studies demonstrated that the probe was internalized in the cells via the PTS. In vivo measurements indicated a tumour to muscle scintigraphic ratio of 7.9{+-}2.8. The combined bioluminescence and scintigraphic analyses with the leukaemia model demonstrated that the spermine conjugate accumulates into the tumour cells. The {sup 99m}Tc-HYNIC-spermine scintigraphic probe is potentially useful to characterize the PTS activity of tumours. Additional work is needed to determine if this novel conjugate may be useful to analyse the PTS status of patients with solid tumours. (orig.)

  14. Scintigraphic evaluation of brain death with 99mTc-d,l-hexamethyl-propyleneamine oxime (HMPAO)

    International Nuclear Information System (INIS)

    Takehara, Yasuo; Isoda, Haruo; Sakai, Tsuneo; Tanaka, Tokutaro; Sato, Haruhiko; Yamamoto, Takamichi; Takahashi, Motoichiro; Kaneko, Masao.

    1989-01-01

    Lately, the criteria of brain death is being discussed. Cerebral scintigram, especially scintigraphic evaluation of brain death by dynamic study, has been previously reported. Cerebral imaging using radiolabeled amines such as 123 I-IMP N-isopropyl-p-iodoamphetamin (IMP) or 99m Tc d, l-hexamethyl-propyleneamine oxime (HMPAO) offers a significant information of brain death by the finding of 'non visualized brain'. However, the dynamic scintigram acquired during the bolus injection of 99m Tc-HMPAO provides an additional information of brain death by classical 'hot nose sign'. 99m Tc-HMPAO is able to be administered relatively in a large amount of dose. This cerebral perfusion tracer is lipophilic and remains in the central nervous system, which characterize its role as a reliable indicator of cerebral blood flow. As a result, this compound became suitable for the non-invasive study of brain circulation when the diagnosis of brain death is uncertain. We report a case of brain death in which diagnosis was made by the classical 'hot nose sign' in dynamic scintigraphy performed when 99 mTc-HMPAO was injected as well as the SPECT which showed a lack of cerebral visualization at the equilibrium state. As far as we are informed, this additional procedure used in the diagnosis of brain death has not reported before. The importance of performing a dynamic scintigram at the administration of 99m Tc-HMPAO is also discussed in this report. (author)

  15. Applications of phase-contrast x-ray imaging to medicine using an x-ray interferometer

    Science.gov (United States)

    Momose, Atsushi; Yoneyama, Akio; Takeda, Tohoru; Itai, Yuji; Tu, Jinhong; Hirano, Keiichi

    1999-10-01

    We are investigating possible medical applications of phase- contrast X-ray imaging using an X-ray interferometer. This paper introduces the strategy of the research project and the present status. The main subject is to broaden the observation area to enable in vivo observation. For this purpose, large X-ray interferometers were developed, and 2.5 cm X 1.5 cm interference patterns were generated using synchrotron X-rays. An improvement of the spatial resolution is also included in the project, and an X-ray interferometer designed for high-resolution phase-contrast X-ray imaging was fabricated and tested. In parallel with the instrumental developments, various soft tissues are observed by phase- contrast X-ray CT to find correspondence between the generated contrast and our histological knowledge. The observation done so far suggests that cancerous tissues are differentiated from normal tissues and that blood can produce phase contrast. Furthermore, this project includes exploring materials that modulate phase contrast for selective imaging.

  16. PHASED ARRAY FEED CALIBRATION, BEAMFORMING, AND IMAGING

    International Nuclear Information System (INIS)

    Landon, Jonathan; Elmer, Michael; Waldron, Jacob; Jones, David; Stemmons, Alan; Jeffs, Brian D.; Warnick, Karl F.; Richard Fisher, J.; Norrod, Roger D.

    2010-01-01

    Phased array feeds (PAFs) for reflector antennas offer the potential for increased reflector field of view and faster survey speeds. To address some of the development challenges that remain for scientifically useful PAFs, including calibration and beamforming algorithms, sensitivity optimization, and demonstration of wide field of view imaging, we report experimental results from a 19 element room temperature L-band PAF mounted on the Green Bank 20 Meter Telescope. Formed beams achieved an aperture efficiency of 69% and a system noise temperature of 66 K. Radio camera images of several sky regions are presented. We investigate the noise performance and sensitivity of the system as a function of elevation angle with statistically optimal beamforming and demonstrate cancelation of radio frequency interference sources with adaptive spatial filtering.

  17. Grid-Independent Compressive Imaging and Fourier Phase Retrieval

    Science.gov (United States)

    Liao, Wenjing

    2013-01-01

    This dissertation is composed of two parts. In the first part techniques of band exclusion(BE) and local optimization(LO) are proposed to solve linear continuum inverse problems independently of the grid spacing. The second part is devoted to the Fourier phase retrieval problem. Many situations in optics, medical imaging and signal processing call…

  18. An efficient reconstruction algorithm for differential phase-contrast tomographic images from a limited number of views

    International Nuclear Information System (INIS)

    Sunaguchi, Naoki; Yuasa, Tetsuya; Gupta, Rajiv; Ando, Masami

    2015-01-01

    The main focus of this paper is reconstruction of tomographic phase-contrast image from a set of projections. We propose an efficient reconstruction algorithm for differential phase-contrast computed tomography that can considerably reduce the number of projections required for reconstruction. The key result underlying this research is a projection theorem that states that the second derivative of the projection set is linearly related to the Laplacian of the tomographic image. The proposed algorithm first reconstructs the Laplacian image of the phase-shift distribution from the second-derivative of the projections using total variation regularization. The second step is to obtain the phase-shift distribution by solving a Poisson equation whose source is the Laplacian image previously reconstructed under the Dirichlet condition. We demonstrate the efficacy of this algorithm using both synthetically generated simulation data and projection data acquired experimentally at a synchrotron. The experimental phase data were acquired from a human coronary artery specimen using dark-field-imaging optics pioneered by our group. Our results demonstrate that the proposed algorithm can reduce the number of projections to approximately 33% as compared with the conventional filtered backprojection method, without any detrimental effect on the image quality

  19. Evaluation of fatty liver by using in-phase and opposed-phase MR images and in-vivo proton MR spectroscopy

    Science.gov (United States)

    Lee, Jae-Seung; Im, In-Chul; Goo, Eun-Hoe; Park, Hyong-Hu; Kwak, Byung-Joon

    2012-12-01

    The purpose of this study was to evaluate the necessity of in-phase and opposed-phase MR images and their correlations with weight, the aspartate aminotransferase/alanine aminotransferase (AST/ALT) value, and age. Magnetic resonance spectroscopy (MRS) was used as a reference in this study. We selected 68 people as subjects, among which 14 were volunteers with normal AST/ALT values ( liver function study and 54 were non-alcoholic fatty liver patients for whom ultrasonic images had been obtained within 3 months of the study. In this study, the liver was more enhanced than the spleen or kidney. When the Eq. (3) formula was applied to normal volunteers, the difference between the in-phase and the opposed-phase images was -3.54 ± 12.56. The MRS study result showed a high sensitivity of 96.6% and a specificity of 100% ( p = 0.000) when the cutoff value was 20%. Furthermore, this result showed a high sensitivity of 94% and a specificity of 80% with a similar cutoff when the Eq. (2) formula was applied to non-alcoholic fatty liver patients ( p = 0.000). The MRS study revealed a strong correlation between normal volunteers and non-alcoholic fatty liver patients (r = 0.59, p = 0.04). The correlations between AST/ALT and Eq. (3) (r = 0.45, p = 0.004), age and Eq. (3) (r = 0.73, p = 0.03), and weight and Eq. (3) (r = 0.77, p = 0.000) values were all statistically significant. In the case of non-alcoholic liver disease, MRS was found to be significantly correlated with Eq. (1) (r = 0.39, p = 0.002), Eq. (2) (r = 0.68, p = 0.04), Eq. (3) (r = 0.67, p = 0.04), and AST/ALT (r = 0.77, p = 0.000). In conclusion, in-phase and opposed-phase images can help to distinguish a normal liver from a fatty liver in order to identify non-alcoholic fatty liver patients. The intensity difference between the in-phase and opposed-phase MR signals showed valuable correlations with respect to weight, AST/ALT value, and age, with all values being above the mild lipid value (r = 0.3).

  20. Microscopy imaging and quantitative phase contrast mapping in turbid microfluidic channels by digital holography.

    Science.gov (United States)

    Paturzo, Melania; Finizio, Andrea; Memmolo, Pasquale; Puglisi, Roberto; Balduzzi, Donatella; Galli, Andrea; Ferraro, Pietro

    2012-09-07

    We show that sharp imaging and quantitative phase-contrast microcopy is possible in microfluidics in flowing turbid media by digital holography. In fact, in flowing liquids with suspended colloidal particles, clear vision is hindered and cannot be recovered by any other microscopic imaging technique. On the contrary, using digital holography, clear imaging is possible thanks to the Doppler frequency shift experienced by the photons scattered by the flowing colloidal particles, which do not contribute to the interference process, i.e. the recorded hologram. The method is illustrated and imaging results are demonstrated for pure phase objects, i.e. biological cells in microfluidic channels.