WorldWideScience

Sample records for schools ceiling insulating

  1. The Impact of Roof Pitch and Ceiling Insulation on Cooling Load of Naturally-Ventilated Attics

    Directory of Open Access Journals (Sweden)

    Linxia Gu

    2012-07-01

    Full Text Available A 2D unsteady computational fluid dynamics (CFD model is employed to simulate buoyancy-driven turbulent ventilation in attics with different pitch values and ceiling insulation levels under summer conditions. The impacts of roof pitch and ceiling insulation on the cooling load of gable-roof residential buildings are investigated based on the simulation of turbulent air flow and natural convection heat transfer in attic spaces with roof pitches from 3/12 to 18/12 combined with ceiling insulation levels from R-1.2 to R-40. The modeling results show that the air flows in the attics are steady and exhibit a general streamline pattern that is qualitatively insensitive to the investigated variations of roof pitch and ceiling insulation. Furthermore, it is predicted that the ceiling insulation plays a control role on the attic cooling load and that an increase of roof pitch from 3/12 to 8/12 results in a decrease in the cooling load by around 9% in the investigated cases. The results suggest that the increase of roof pitch alone, without changing other design parameters, has limited impact on attics cooling load and airflow pattern. The research results also suggest both the predicted ventilating mass flow rate and attic cooling load can be satisfactorily correlated by simple relationships in terms of appropriately defined Rayleigh and Nusselt numbers.

  2. Investigation of floor Nusselt number in floor heating system for insulated ceiling conditions

    International Nuclear Information System (INIS)

    Karadag, Refet; Teke, Ismail

    2007-01-01

    In this study, in a floor heated room, natural convection heat transfer over the floor is analysed numerically for different thermal conditions. An equation relevant to Nusselt number over the floor has been obtained by using the numerical data. Different equations are given in the literature. They consider the effect of floor Rayleigh number while neglecting the effect of wall and ceiling thermal conditions. Numerical data obtained in this study show that the Nusselt number over the floor depends on not only the floor Rayleigh number but also the wall Rayleigh number (for insulated ceiling conditions). The equations given in the literature are different from each other due to their not considering the effect of wall and ceiling Rayleigh numbers. This difference between the equations may be eliminated by obtaining an equation containing the effect of floor, wall and ceiling Rayleigh numbers. In this new approach, an equation relevant to the floor Nusselt number that depends on the floor and wall Rayleigh numbers has been obtained in the floor heating system for insulated ceiling conditions. The equation obtained in this study has been compared with the equations given in the literature. It has been seen that the equation obtained in this study matches the numerical values under more extensive thermal conditions than the equations given in the literature. The maximum deviation for the equations given in the literature is 35%, but in the current study, the maximum deviation has been found to be 10%. As a result, it is more convenient to use the equation found in the new approach as a function of Rayleigh number over the floor and wall for insulated ceiling conditions

  3. Determination of optimum insulation thicknesses of the external walls and roof (ceiling) for Turkey's different degree-day regions

    International Nuclear Information System (INIS)

    Sisman, Nuri; Kahya, Emin; Aras, Nil; Aras, Haydar

    2007-01-01

    The external walls and roof of a building are the interface between its interior and the outdoor environment. Insulation of the external walls and roof is the most cost-effective way of controlling the outside elements to make homes more comfortable. Although insulation is generally accepted as a factor increasing the building costs, with the calculations we have shown that this is not the case. Fuel consumption and operational costs are reduced by increasing the thickness of the external walls and roof (ceiling), despite an increase in the investment costs. According to Turkish Standard Number 825 (TS 825), there are four different degree-day (DD) regions, and the required heat loads for the buildings in these regions exhibit large differences. Therefore, a method based on costs is needed for the determination of optimum insulation thicknesses of different DD regions. In this study, optimum insulation thicknesses for different DD regions of Turkey, namely, Izmir (DD: 1450), Bursa (DD: 2203), Eskisehir (DD: 3215) and Erzurum (DD: 4856), have been determined for a lifetime of N years, maximizing the present worth value of annual energy savings for insulated external walls

  4. Field measurements of moisture variation in cold ventilated attics with different ceiling constructions

    DEFF Research Database (Denmark)

    Hansen, Thor; Møller, Eva B.

    2017-01-01

    Adding insulation material on ceilings against cold ventilated attics is one of the most straightforward tasks of adding insulation. Theoretically, a higher amount of insulation in the attic decreases the temperature and consequently the capability of removing infiltrated indoor humid air. Field...

  5. Making Sense of the Glass Ceiling in Schools: An Exploration of Women Teachers' Discourses

    Science.gov (United States)

    Moreau, Marie-Pierre; Osgood, Jayne; Halsall, Anna

    2007-01-01

    There is extensive evidence of a "glass ceiling" for women across the labour market. Though schools have widely been described as "feminized" work environments, the under-representation of women at school management level is well established. Based on a study of women teachers' careers and promotion in the English school sector…

  6. Thermal insulating system particularly adapted for building construction

    International Nuclear Information System (INIS)

    Dyar, H.G.

    1985-01-01

    This disclosure relates to an insulating system which is particularly adapted for insulating the walls, floors, ceilings and like structure of buildings and includes a panel having a hollow chamber or interior under negative pressure (vacuum) and being of a variety of external peripheral sizes and shapes to fit within areas defined by wall and/or floor and/or ceiling studs, beams, or the like, a plurality of springs, chains or the like for supporting the panel in generally spaced relationship to an associated building wall, ceiling, floor or like structure, and a plurality of pin-like elements of relatively small cross-sectional configuration normally spaced from the exterior surface of the panel for contacting a limited exterior surface area of the panel only upon the springs, chains or the like becoming inoperative which would in the absence of the pin-like elements result in direct contact between the panel and the associated building wall, ceiling, floor or like structure and thus reduce the insulating efficiency thereof

  7. Field evaluation of reflective insulation in south east Asia

    Science.gov (United States)

    Teh, Khar San; Yarbrough, David W.; Lim, Chin Haw; Salleh, Elias

    2017-12-01

    The objective of this research was to obtain thermal performance data for reflective insulations in a South East Asia environment. Thermal resistance data (RSI, m2 ṡ K/W) for reflective insulations are well established from 1-D steady-state tests, but thermal data for reflective insulation in structures like those found in South East Asia are scarce. Data for reflective insulations in South East Asia will add to the worldwide database for this type of energy-conserving material. RSI were obtained from heat flux and temperature data of three identical structures in the same location. One unit did not have insulation above the ceiling, while the second and third units were insulated with reflective insulation with emittance less than 0.05. RSI for the uninsulated test unit varied from 0.37 to 0.40 m2 ṡ K/W. RSI for a single-sheet reflective insulation (woven foil) varied from 2.15 to 2.26 m2 ṡ K/W, while bubble-foil insulation varied from 2.69 to 3.09 m2 ṡ K/W. The range of RSI values resulted from differences in the spacing between the reflective insulation and the roof. In addition, the reflective insulation below the roof lowered attic temperatures by as much as 9.7° C. Reductions in ceiling heat flux of 80 to 90% relative to the uninsulated structure, due to the reflective insulation, were observed.

  8. The effects of receiving room dimensions and absorption in the measurement of impact insulation class (IIC) rating

    Science.gov (United States)

    Su, Rose Mary; Tocci, Gregory

    2005-09-01

    The measurement of the Impact Insulation Class (IIC) rating of any floor/ceiling construction requires the use of a certified laboratory space. In a recent investigation into the IIC rating of a new floor system, several tests were conducted in a certified laboratory. In many tests, the IIC rating was controlled by the 100-Hz 1/3-octave frequency band, despite changes in the floor/ceiling construction. The base floor/ceiling construction included a wood structural floor on open-web wood joists and a GWB ceiling below. This paper will investigate the possibility that room resonances influenced the IIC ratings of the several floor systems tested. These data will be compared with IIC data collected for the same floor construction with the GWB ceiling removed. The removal of the GWB ceiling increased the receiver room volume and exposed the glass fiber insulation to the receiver room, thus eliminating the control of the 100-Hz 1/3-octave band over the IIC rating.

  9. Multiple Glass Ceilings

    OpenAIRE

    Russo, Giovanni; Hassink, Wolter

    2011-01-01

    Both vertical (between job levels) and horizontal (within job levels) mobility can be sources of wage growth. We find that the glass ceiling operates at both margins. The unexplained part of the wage gap grows across job levels (glass ceiling at the vertical margin) and across the deciles of the intra-job-level wage distribution (glass ceiling at the horizontal margin). This implies that women face many glass ceilings, one for each job level above the second, and that the glass ceiling is a p...

  10. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as air diffuser to supply fresh air into the room. Compared with conventional ventilation systems, diffuse ceiling ventilation can significantly reduce or even eliminate draught risk due to the low...

  11. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per; Nielsen, Peter V.

    2014-01-01

    As a novel air distribution system, diffuse ceiling ventilation combines the suspended acoustic ceiling with ventilation supply. Due to the low-impulse supply from the large ceiling area, the system does not generate draught when supplying cold air. However, heat sources play an important role...

  12. Suspended ceilings

    Energy Technology Data Exchange (ETDEWEB)

    Talamo, C.

    1991-05-01

    The retrofitting of existing conventional ceiling systems to suspended ceiling type systems represents an interesting energy savings solution since this method, in addition to providing additional protection against space heat loss and thermal bridges, also creates the possibility of housing, in the void, additional mechanical and electrical lines which may be necessary due to other savings interventions. This paper reviews the various suspended ceiling systems (e.g., those making use of mineral fibre, gypsum panels, wood, vermiculite, etc.) currently marketed in Europe, and reports, for each, some key technical, economic and architectural advantages which include thermal efficiency, noise abatement, as well as, resistance to fire and humidity. Information is also given on the relative installation and maintenance requirements.

  13. Heavy Metal Concentrations in Ceiling Fan Dusts Sampled at Schools Around Serdang Area, Selangor

    International Nuclear Information System (INIS)

    Yap, C.K.; Krishnan, T.; Chew, W.

    2011-01-01

    In this study, ceiling fan dust samples were collected from three schools in the district of Serdang Selangor, Malaysia. The sampled dust were analysed for the concentrations of Cd, Cu, Fe, Ni, Pb and Zn. The heavy metal ranges found in all the schools were 2.96-7.74 μg/ g dry weight for Cd, 75-442 μg/ g dry weight for Cu, 3445-3852 μg/ g dry weight for Fe, 24-66 μg/ g dry weight for Ni, 140-734 μg/ g dry weight for Pb and 439-880 μg/ g dry weight for Zn. SMK Seri Serdang School was found to have elevated concentrations of Cd, Cu, Ni, Pb, and Zn which indicated the anthropogenic sources of the study sites. In comparison to other reported studies in the literature, the maximum levels of Cd, Cu, Ni, and Pb were comparable or higher to those cities reported. Therefore, more monitoring studies should be conducted in future since dusts could be related to human health hazards and the dusts can be used as a potential monitoring tool for heavy metal pollution in the atmosphere. (author)

  14. ENERGY STAR Certified Ceiling Fans

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Ceiling Fans that are effective as of April 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=ceiling_fans.pr_crit_ceiling_fans

  15. Modeling of Ceiling Fire Spread and Thermal Radiation.

    Science.gov (United States)

    1981-10-01

    under a PMMA ceiling and flame lengths under an inert ceiling are found to be in reasonable agreement with full-scale behavior. Although fire spread...5 3 Flame Lengths under Full-Scale Ceilings 12 4 Correlation of Flame Length under Inert Ceilings 16 5 Correlation of Flame Length under No 234 Model...Ceilings 17 6 Correlation of Flame Length under No B8811 Model Ceilings 18 7 Correlation of Flame Length under No. 223 Model Ceilings 19 8

  16. 48 CFR 452.216-74 - Ceiling Price.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Ceiling Price. 452.216-74... SOLICITATION PROVISIONS AND CONTRACT CLAUSES Texts of Provisions and Clauses 452.216-74 Ceiling Price. As prescribed in 416.670, insert the following clause: Ceiling Price (FEB 1988) The ceiling price of this...

  17. The Glass Ceiling for Women in Legal Education: Contract Positions and the Death of Tenure.

    Science.gov (United States)

    Angel, Marina

    2000-01-01

    Discussion of the glass ceiling for women in legal education first examines categories of law school personnel, especially the fast-growing category of legal-writing teachers, and then considers trends in law school hiring. Concludes that law school trends mirror those in college and university hiring generally, suggesting the weakening and…

  18. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    cooling capacity, energy saving, low investment cost and low noise level; while the limitations include condensation risk and the limit on the room geometry. Furthermore, the crucial design parameters are summarized and their effects on the system performance are discussed. In addition to the stand...... is not well structured with this system. These become the motivations in developing the design guide. This design guide aims to establish a systematic understanding of diffuse ceiling ventilation and provide assistance in designing of such a system. The guide is targeted at design engineers, architects...... and manufacturers and the users of diffuse ceiling technology. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation. It provides an overview of potential benefit and limitations of this technology. The benefits include high thermal comfort, high...

  19. Jagged Edges of the Glass Ceiling

    Science.gov (United States)

    Robinson, Victoria L.

    2004-01-01

    Although many aspiring young women might believe the glass ceiling was shattered a decade ago, they still need to understand how that glass ceiling impacted an older generation of women in educational leadership. They also must be aware that some segments of the glass ceiling might still exist. This article provides a historical overview of the…

  20. Reflective Insulation for Energy Conservation in South East Asia

    Science.gov (United States)

    San Teh, Khar; Yarbrough, David W.; Haw Lim, Chin; Salleh, Elias

    2017-05-01

    Thermal resistances have been measured for attic spaces insulated with reflective insulations. Three test units located in Malaysia were instrumented to provide heat flux and temperatures for the calculation of time-average RSI-values (RSI is representing R-value in SI units). The RSI for attics with enclosed reflective air spaces were in the range 2-3 m2·K/W while the uninsulated attics averaged about 0.4 m2·K/W. The RSI-values determined in this project were for heat-flow down, the predominant heat-flow direction for attic spaces in Equatorial regions. The observed thermal resistances due to the installation of the reflective insulation results in an 80-90% annual decrease in the heat transfer across the ceiling. This reduces utility usage for air conditioned units and improved comfort for occupants. The research demonstrates the use of transient data for the determination of thermal insulation performance and usefulness of enclosed reflective air spaces for thermal resistance.

  1. Metabolic rate and clothing insulation data of children and adolescents during various school activities

    NARCIS (Netherlands)

    Havenith, G.

    2007-01-01

    Data on metabolic rates (n = 0;81) and clothing insulation (n = 96) of school children and adolescents (A, primary school: age 9-10; B, primary school: age 10-11 year; C, junior vocational (technical) education: age 13-16 (lower level); D, same as C but at advanced level; and E, senior vocational

  2. 16 CFR 305.13 - Labeling for ceiling fans.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Labeling for ceiling fans. 305.13 Section... Disclosures § 305.13 Labeling for ceiling fans. (a) Ceiling fans—(1) Content. Any covered product that is a ceiling fan shall be labeled clearly and conspicuously on the principal display panel with the following...

  3. Diversity, culture and the glass ceiling.

    Science.gov (United States)

    Wilson, Eleanor

    2014-01-01

    A reference to the term, the glass ceiling, has come to embody more than gender equality among women and men. Today the term embraces the quest of all minorities and their journey towards equality in the workplace. The purpose of this article is to bring attention to the subject of diversity, culture, and the glass ceiling. The article will discuss the history of the glass ceiling and how its broadened meaning is relevant in today's workplace. It will also provide statistics showing how diversity and culture are lacking among the top echelon of today's executives, the barriers faced by minorities as they journey towards executive leadership, and how to overcome these barriers to truly shatter the glass ceiling.

  4. Measuring perceived ceiling height in a visual comparison task.

    Science.gov (United States)

    von Castell, Christoph; Hecht, Heiko; Oberfeld, Daniel

    2017-03-01

    When judging interior space, a dark ceiling is judged to be lower than a light ceiling. The method of metric judgments (e.g., on a centimetre scale) that has typically been used in such tasks may reflect a genuine perceptual effect or it may reflect a cognitively mediated impression. We employed a height-matching method in which perceived ceiling height had to be matched with an adjustable pillar, thus obtaining psychometric functions that allowed for an estimation of the point of subjective equality (PSE) and the difference limen (DL). The height-matching method developed in this paper allows for a direct visual match and does not require metric judgment. It has the added advantage of providing superior precision. Experiment 1 used ceiling heights between 2.90 m and 3.00 m. The PSE proved sensitive to slight changes in perceived ceiling height. The DL was about 3% of the physical ceiling height. Experiment 2 found similar results for lower (2.30 m to 2.50 m) and higher (3.30 m to 3.50 m) ceilings. In Experiment 3, we additionally varied ceiling lightness (light grey vs. dark grey). The height matches showed that the light ceiling appeared significantly higher than the darker ceiling. We therefore attribute the influence of ceiling lightness on perceived ceiling height to a direct perceptual rather than a cognitive effect.

  5. Building thermal loads: A case study for David Hellen Petta public secondary school

    CSIR Research Space (South Africa)

    Kumirai, T

    2013-03-01

    Full Text Available This chapter assesses the impact of appropriate passive interventions on building thermal loads. The passive interventions investigated are ceiling insulation, wall insulation, attic ventilation, natural ventilation and roof absorptance and also...

  6. 48 CFR 1352.216-77 - Ceiling price.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Ceiling price. 1352.216-77... SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions and Clauses 1352.216-77 Ceiling price. As prescribed in 48 CFR 1316.601-70 and 1316.602-70, insert the following clause: Ceiling Price (APR 2010) The...

  7. Teaching Acoustic Properties of Materials in Secondary School: Testing Sound Insulators

    Science.gov (United States)

    Hernandez, M. I.; Couso, D.; Pinto, R.

    2011-01-01

    Teaching the acoustic properties of materials is a good way to teach physics concepts, extending them into the technological arena related to materials science. This article describes an innovative approach for teaching sound and acoustics in combination with sound insulating materials in secondary school (15-16-year-old students). Concerning the…

  8. An Economic Theory of Glass Ceiling

    OpenAIRE

    Paul A. Grout; In-Uck Park; Silvia Sonderegger

    2009-01-01

    In the 'glass ceiling' debate there appear to be two strongly held and opposing interpretations of the evidence, one suggesting it is really the result of gender differences and the other that there is discrimination by gender. This paper provides an economic theory of the glass ceiling and one of the main insights of our analysis is that in some real sense these two interpretations are not in conflict with each other. The glass ceiling emerges as an equilibrium phenomenon when firms compete ...

  9. An Analysis of Insulated Concrete Forms for use in Sustainable Military Construction

    Science.gov (United States)

    2014-03-27

    the building foundation, exterior walls, ceiling, roof, doors, windows and even the interior wall insulation ( Lemieux & Totten, 2010). With a focus...the various elements comprising a typical wall system. 19 Figure 5. Wall System Components ( Lemieux & Totten, 2010) The exterior cladding is...interior of the building and, conversely, inside air from infiltrating outside ( Lemieux & Totten, 2010). The vapor retarder protects the interior wall

  10. Stars on the Ceiling

    Science.gov (United States)

    Krupp, E. C.

    2016-01-01

    Astronomy and celestial imagery have been incorporated into architectural ceilings from antiquity to the present to reference the sky on behalf of a variety of agendas. Burial chambers in Egyptian pyramids and tombs, the Osiris chapel on the roof of Ptolemaic Egypt's Temple of Dendera, ancient Chinese tombs, painted rock shelters in California and the American Southwest, the cupola above a hot bath from medieval Jordan, elaborately illustrated ceilings in Italian cathedrals and palaces, the main concourse in New York's Grand Central Terminal, and a variety of other public buildings in America all brought the sky inside to convey relationships between the architecture, people, and the cosmos. In these interior environments, the symbolic function of the astronomical ceiling is driven by the thematic function of the building. At Griffith Observatory in Los Angeles three signature spaces are equipped with astronomically illustrated ceilings. In content and location, these prominent murals operate symbolically to convey meaning through public display and unexpectedly prompt people to think more expansively about the universe. This artwork is familiar in Los Angeles, but its use in a public observatory puts it outside the range of most commentaries on public art. Although experienced by more than seventy-six million persons over the last eighty years, Griffith Observatory's celestial murals are not well known. Their history, content, character, meaning, and purpose are detailed here.

  11. Experimental study of diffuse ceiling ventilation in classroom

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Terkildsen, Søren

    Diffuse ceiling ventilation is a novel air distribution device that combines the suspended acoustic ceiling with ventilation supply. A diffuse ceiling distributes the supply air above the acoustic tiles and has proven performance in laboratory experiments. To study the performance in real conditi...

  12. Handbook of Thermal Insulation Applications.

    Science.gov (United States)

    1983-01-01

    Wiuppuoror *tIe beamsWiefag ln~ td ~oair ilmstool beams Plate 18. Metal Building Ceilings - A 18b: Fir* hataird rathge may limit the use of foam Insulation...RFCTANGUI.AR SOL TD A = 2(WxL+LxH+HxW) B V = WxLxH H L TRAPEZOID A 2 (A + B) x H A CONE A -n xRxS+ i xR 2 B V =( /3)x R2 x H TRIANGLE A BxH A- 2 CYLI NDER H 2...FABRICATIIG RECTANGULAR HEATING AND COOLING DUCTWORK. FIBERGLAS DUCT BOARD OWENS-CORNING FIBERGLAS CORP GLASS FIBER RIGID BOARD WITH ALUMINUM 4bD FOIL VAPOR

  13. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan

    2017-01-01

    A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large ......-uniformity air distribution and further led to the draught problem in the occupied zone. This system was recommended to apply in the small offices instead of large, open spaces....

  14. Component for the manufacture of sound and thermally insulating shell for walls, ceilings or floors. Baueelement fuer die Herstellung einer schall- und/oder waermedaemmenden Vorsatzschale fuer Waende, Decken und Boeden

    Energy Technology Data Exchange (ETDEWEB)

    Muehldorfer, H

    1977-07-04

    The invention concerns a component for the manufacture of a sound and/or thermally insulating shell for walls, ceilings or floors, which can be connected to these and is used directly to carry the cover plates or the plaster as an ouside shell. The problem is solved by having the component consisting of two spring loaded connected profiles, whose free ends, as seen in cross section, overlap with play in the operating position. There is a pin to connect the two profiles, which passes through openings in the free ends of the profiles and is elastically supported in them. The profiles may be made of metal, wood or plastic material. Compared with the well known ''swinging timbers'', the component is distinguished by the fact that the whole cladding can be covered with fibrous feld, instead of the strips of fibrous felt between the rows of swinging timbers, and the component can therefore be fixed to the wall.

  15. Fresh-air cooling ceilings in an administration building; Frischluft-Kuehldecken in einem Verwaltungsgebaeude

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1995-06-01

    In the construction of the new building of the Deutsche Innenbau GmbH in Muelheim much importance was attached to aesthetics and functionality. If the employees are enthusiastic after one year of operation this is mainly due to the ideal climatic conditions: Glazings with insulating glass (k=1,4 W/m{sup 2}k), high-quality thermal insulation of the breasts shading system with motor-driven screen at the outside, radiators with thermostatic valves and a fresh air cooling ceiling. The article describes the course of construction of the total air-conditioning and ventilation technique. (orig.) [Deutsch] Beim Neubau der DIG Deutsche Innenbau GmbH in Muelheim an der Ruhr legte man grossen Wert auf Aesthetik und Funktionalitaet. Wenn die Mitarbeiter nach einem Jahr Betrieb begeistert sind, so liegt dies grossenteils an idealen klimatechnischen Voraussetzungen: Verglasung mit Waermeschutzglas (K=1,4 W/m{sup 2}K), hochwertige Waermedaemmung der Bruestungen, aussenliegender Sonnenschutz mit motorbetaetigten Raffstoren, Radiatoren mit Thermostatventilen und einem Frischluft-Kuehldecken-System. Dieser Beitrag beschreibt die Vorgehensweise beim Bau der gesamten Klima- und Lueftungstechnik. (orig.)

  16. The Glass Ceiling Initiative. A Report.

    Science.gov (United States)

    Department of Labor, Washington, DC.

    While minorities and women have made considerable gains in entering the workforce in the last few decades, there remains a dearth of minorities and women at management levels. This phenomenon has come to be known as the "glass ceiling." The Department of Labor defines the glass ceiling as those artificial barriers based on attitudinal or…

  17. The glass ceiling in nursing management.

    Science.gov (United States)

    Crawford, D I

    1993-01-01

    Women managers in business and health care have experienced discrimination related to advancement in management. Nurse executives must understand the strategies to overcome the barriers, the "glass ceiling," as well as implications for future practice. Women executives need an organized blueprint and the tools to dismantle the glass ceiling and overcome the political and discriminatory barriers to success.

  18. The Leger house: an affordable super insulated home

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2000-03-01

    Building and energy efficient house in a cost-effective manner is not an easy task. The house described in this article is a 1200 sq.ft house, built on the principle of the Arkansas house, a sophisticated example of advanced wood frame construction, meets both these requirements, i.e. it is both energy efficient and good value for the money. It is built on a cast-in place concrete foundation with advanced framing construction techniques, staggered studs spaced on 24 inch centres, on separate plates forming an eight inch thick wall. The exterior sheathing is Dow Styrofoam, over which vinyl siding is installed. Thermal bridging, which is the weak point in conventional framing, received special attention. The outer walls are placed in such a way that they do not touch the floor joist and the plywood subfloor. Windows are wood framed, double glazed, a combination of casement and double hung, with storm windows, and sliding units. The clear span roof truss design gives the freedom of an open interior allowing a continuous unbroken ceiling vapour diffusion retarder. Drywall and oak flooring was installed without interference from partitions which were installed after the ceiling and the floor were in place. All lighting fixtures are on the partitions, so there is no need for penetration of the top plates in the partitions. Similarly, there is no wiring or plumbing in the exterior walls. Insulated steel doors, with magnetic weather stripping open to two airlocks. Domestic hot water and space heating is provided by a tank-less 43,800 Btu/hr Paloma natural gas heater. The water is kept at 160 degrees F and supplied to 46 feet of baseboard. A small conventional air-conditioning unit is installed but was only used for or a total of 12 hours since 1979, since during most of the hot summer days the rooms remain satisfactorily cool at about 80 degrees F, provided doors and windows are kept shut. A heat recovery ventilator has been installed subsequently, but is not considered

  19. Glass Ceiling : Women in management

    OpenAIRE

    Rantala, Virve

    2010-01-01

    This study has examined the phenomenon called Glass Ceiling. It has approached the phenomenon in two different views. One is career development and another one is women in management. Main purpose for this study was to inspect women working life and career opportunities. Why women’s career developments end in a certain level? What is glass ceiling and how to break it? Paper also investigates reasons behind the effect. Prejudices and biases are the worst enemies for women’s career. How to chan...

  20. Raising the "glass ceiling" for ethnic minority women in health care management.

    Science.gov (United States)

    Kumar, R; Johnston, G

    1999-01-01

    Ethnic minority women are well represented in the work force and in the health care system in general, but do not have a similar level of representation in the management sector. This paper explores three strategies for schools of health administration to consider to lessen the effect of a "glass ceiling" that may be encountered by ethnic minority women aspiring to positions of leadership in health services agencies. These strategies are advancing affirmative action, valuing ethnic women in health administration education, and investigating diversity management. Inherent in each of the three strategies is the need for acknowledgment and more open discussion of the "glass ceiling." Problem-solving in relation to the potential for systemic discrimination adversely affecting ethnic minority women in senior health care management positions, and greater study of the three strategies using both qualitative and quantitative methodologies is also needed.

  1. 48 CFR 217.7404-2 - Price ceiling.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Price ceiling. 217.7404-2 Section 217.7404-2 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Contract Actions 217.7404-2 Price ceiling. UCAs shall include a not-to-exceed price. ...

  2. Development and evaluation of a ceiling ventilation system enhanced by solar photovoltaic thermal collectors and phase change materials

    International Nuclear Information System (INIS)

    Lin, Wenye; Ma, Zhenjun; Sohel, M. Imroz; Cooper, Paul

    2014-01-01

    Highlights: • A novel ceiling ventilation system enhanced by PVT and PCMs was proposed. • PCM was used to increase the local thermal mass and to serve as a storage unit. • The proposed system can enhance indoor thermal comfort in winter and summer. - Abstract: This paper presents the development and performance evaluation of a novel ceiling ventilation system integrated with solar photovoltaic thermal (PVT) collectors and phase change materials (PCMs). The PVT collectors are used to generate electricity and provide low grade heating and cooling energy for buildings by using winter daytime solar radiation and summer night-time sky radiative cooling, respectively. The PCM is integrated into the building ceiling as a part of the ceiling insulation and at the same time, as a centralized thermal energy storage to temporally store low grade energy collected from the PVT collectors. The performance of the proposed system was numerically evaluated based on a Solar Decathlon house using TRNSYS. The results showed that, in winter conditions, the proposed PVT–PCM integrated ventilation system can significantly improve the indoor thermal comfort of passive buildings without using air-conditioning systems with a maximum air temperature rise of 23.1 °C from the PVT collectors. Compared with the system using PCM but without using PVT collectors, the coefficient of thermal comfort enhancement in the kitchen, dining room and living room of the case building studied using the proposed system improved from almost zero to 0.9823 while the coefficient of thermal comfort enhancement in the study room improved from 0.0060 to 0.9921. In summer conditions, the proposed system can also enhance indoor thermal comfort through night-time sky radiative cooling

  3. Principle, function, experiences, hybrid chilled ceilings; Prinzip, Funktion, Erfahrungen. Hybrid-Kuehldecken

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Uwe W. [Hochschule Luzern (Switzerland). Technik und Architektur

    2010-12-15

    Hybrid chilled ceilings combine a radiation chilled ceiling with thermal activations of a concrete ceiling. The activation permits the utilization of alternative and/or small cold generators for the efficient night cooling. The traditional chilled ceiling grants a speedy reaction to load variations as well as a reduction of the reverberation periods. In addition, the combination supplies a draught-free insertion of air. Beside established solutions, MWH Barcol-Air (Staefa, Switzerland) also offers project-specific hybrid chilled ceilings.

  4. Breaking the glass ceiling.

    Science.gov (United States)

    Lazarus, A

    1997-03-01

    The glass ceiling is a form of organizational bias and discrimination that prevents qualified professionals from achieving positions of top governance and leadership. This article examines glass ceiling barriers that keep physicians from the upper reaches of management. While these factors apply mainly to women and minority physicians in academia, and are attributable to sexual harassment and discrimination, physicians as a class are frequently denied executive management positions. Such denial results from inadequate preparation for a career in health care administration. Important issues in the professional development of physician executives include mentoring, training and education, administrative experience, and cultural and personality factors. All of those must be considered when making the transition from medicine to management.

  5. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    with conventional ventilation systems (mixing or displacement ventilation), diffuse ceiling ventilation can significantly reduce or even eliminate draught risk in the occupied zone. Moreover, this ventilation system presents a promising opportunity for energy saving, because of the low pressure loss, extended free...

  6. Thermal simulation of different construction types in six climatic regions on heating and cooling loads

    CSIR Research Space (South Africa)

    Kumirai, T

    2012-10-01

    Full Text Available reduces its heating and cooling loads the most. 3. Applying both roof and ceiling insulation should always be avoided. 4. Building insulation is an effective intervention in all climatic regions. 5. Slightly increasing the thermal mass of a wall... were designed to evaluate the following: ? Case A ? base case ? Case B ? insulated walls ? Case C ? insulated walls and insulated ceiling ? Case D ? insulated walls, insulated ceiling and roof ? Case E ? increased thermal mass wall and insulated...

  7. Potential Global Benefits of Improved Ceiling Fan Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Sathaye, Nakul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-31

    Ceiling fans contribute significantly to residential electricity consumption, both in an absolute sense and as a proportion of household consumption in many locations, especially in developing countries in warm climates. However, there has been little detailed assessment of the costs and benefits of efficiency improvement options for ceiling fans and the potential resulting electricity consumption and greenhouse gas (GHG) emissions reductions. We analyze the costs and benefits of several options to improve the efficiency of ceiling fans and assess the global potential for electricity savings and GHG emission reductions with more detailed assessments for India, China, and the U.S. We find that ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terrawatt hours per year (TWh/year) could be saved and 25 million metric tons of carbon dioxide (CO2) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize this savings potential.

  8. What Glass Ceiling?

    Science.gov (United States)

    Lynch, Michael; Post, Katherine

    1996-01-01

    A recent study drawing on data from the Census Bureau and the Bureau of Labor Statistics suggests that the wage gap between men and women has virtually disappeared, and that the so-called "glass ceiling" results more from age and qualifications than from explicit discrimination. (SLD)

  9. Parental leave and the glass ceiling in Sweden

    OpenAIRE

    Albrecht, James; Skogman Thoursie, Peter; Vroman, Susan

    2015-01-01

    In this paper, we update and extend "Is There a Glass Ceiling in Sweden?" (Albrecht et al. 2003) by documenting the extent to which the gender log wage gap across the distribution in Sweden has changed over the period 1998-2008. We then examine the Swedish glass ceiling in 2008 in more detail by documenting how it differs for white-collar versus blue-collar workers and for private- versus public-sector workers. We also examine when in the life cycle the glass ceiling effect arises and how thi...

  10. The Glass Ceiling: Progress and Persistent Challenges

    Science.gov (United States)

    McLlwain, Wendy M.

    2012-01-01

    It has been written that since 2001, there has not been any significant progress and the glass ceiling is still intact. Women are still underrepresented in top positions (Anonymous, 2004). If this is true, the glass ceiling presents a major barrier between women and their desire to advance into executive or senior management positions. In addition…

  11. Evaluation of ceiling lifts in health care settings: patient outcome and perceptions.

    Science.gov (United States)

    Alamgir, Hasanat; Li, Olivia Wei; Gorman, Erin; Fast, Catherine; Yu, Shicheng; Kidd, Catherine

    2009-09-01

    Ceiling lifts have been introduced into health care settings to reduce manual patient lifting and thus occupational injuries. Although growing evidence supports the effectiveness of ceiling lifts, a paucity of research links indicators, such as quality of patient care or patient perceptions, to the use of these transfer devices. This study explored the relationship between ceiling lift coverage rates and measures of patient care quality (e.g., incidence of facility-acquired pressure ulcers, falls, urinary infections, urinary incontinence, and assaults [patient to staff] in acute and long-term care facilities), as well as patient perceptions of satisfaction with care received while using ceiling lifts in a complex care facility. Qualitative semi-structured interviews were used to generate data. A significant inverse relationship was found between pressure ulcer rates and ceiling lift coverage; however, this effect was attenuated by year. No significant relationships existed between ceiling lift coverage and patient outcome indicators after adding the "year" variable to the model. Patients generally approved of the use of ceiling lifts and recognized many of the benefits. Ceiling lifts are not detrimental to the quality of care received by patients, and patients prefer being transferred by ceiling lifts. The relationship between ceiling lift coverage and pressure ulcer rates warrants further investigation. Copyright (c) 2009, SLACK Incorporated.

  12. METHOD FOR EVALUATING MOLD GROWTH ON CEILING TILE

    Science.gov (United States)

    A method to extract mold spores from porous ceiling tiles was developed using a masticator blender. Ceiling tiles were inoculated and analyzed using four species of mold. Statistical analysis comparing results obtained by masticator extraction and the swab method was performed. T...

  13. Costs and benefits of energy efficiency improvements in ceiling fans

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar; Sathaye, Nakul; Phadke, Amol; Letschert, Virginie [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15

    Ceiling fans contribute significantly to residential electricity consumption, especially in developing countries with warm climates. The paper provides analysis of costs and benefits of several options to improve the efficiency of ceiling fans to assess the global potential for electricity savings and green house gas (GHG) emission reductions. Ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terawatt hours per year could be saved and 25 million metric tons of carbon dioxide equivalent (CO2-e) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize potential savings.

  14. 48 CFR 243.204-70-2 - Price ceiling.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Price ceiling. 243.204-70..., DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT CONTRACT MODIFICATIONS Change Orders 243.204-70-2 Price ceiling. Unpriced change orders shall include a not-to-exceed price. [75 FR 48277, Aug. 10, 2010] ...

  15. GROWTH EVALUATION OF FUNGI (PENICILLIUM AND ASPERGILLUS SPP.) ON CEILING TILES

    Science.gov (United States)

    The paper gives results of an evaluation of the potential for fungal growth on four different ceiling tiles in static chambers. It was found that even new ceiling tiles supported fungal growth under favorable conditions. Used ceiling tiles appeared to be more susceptible to funga...

  16. 78 FR 25626 - Energy Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans...

    Science.gov (United States)

    2013-05-02

    ... Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans and Ceiling Fan... for residential ceiling fans and ceiling fan light kits in the Federal Register. This document... other aspect of the rulemaking for ceiling fans and ceiling fan light kits. The comment period is...

  17. Measurements on Buoyant Jet Flows from a Ceiling-Mounted Slot Diffuser

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Möller, Åke T. A.

    Ceiling-mounted slot diffusers in ventilated rooms will often generate a flow of the wall jet type. The jet follows the ceiling, entrains air from the occupied zone and generates a recirculating flow in the whole room. This paper will deal with the flow in the ceiling region. The wall jet flow...

  18. The perception of the glass ceiling phenomenon

    OpenAIRE

    2012-01-01

    M.B.A. Barriers that hinder career advancement of women are both complex and varied. They have become top priority for organizations and the government. The "glass ceiling" is a term that symbolizes a variety of barriers that prevent individuals from advancing up the corporate hierarchy. Although many women hold management positions, few have made the breakthrough to toplevel positions. To determine what conditions are required for women to break the glass ceiling and attain management pos...

  19. Existence of Glass Ceiling in Public Universities of Lahore (Pakistan)

    OpenAIRE

    Asifa Ilyas

    2014-01-01

    Glass ceiling is a set of unseen factors which adversely affect females upward career growth and prevent them to get to top positions. This study is meant to explore existence of glass ceiling in public universities of Lahore (Pakistan); and factors responsible for creating this glass ceiling effect. The respondents of this study are females heading different departments in their respective universities. The results of this study show that different cultural and social, family and organizatio...

  20. 78 FR 16443 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Ceiling Fans...

    Science.gov (United States)

    2013-03-15

    ... Standards for Ceiling Fans and Ceiling Fan Light Kits AGENCY: Office of Energy Efficiency and Renewable... consider amending the energy conservation standards for ceiling fans and ceiling fan light kits. DOE also....gov . Follow the instructions for submitting comments. Email: CeilingFan[email protected

  1. An Economic Theory of the Glass Ceiling

    OpenAIRE

    Paul A. Grout; In-Uck Park; Silvia Sonderegger

    2007-01-01

    The glass ceiling is one of the most controversial and emotive aspects of employment in organisations. This paper provides a model of the glass ceiling that exhibits the following features that are frequently thought to characterise the problem: (i) there is a lower number of female employees in higher positions, (ii) women have to work harder than men to obtain equivalent jobs, (iii) women are then paid less than men when promoted, and (iv) some organisations are more female friendly than ot...

  2. An acoustical research of the undulating wooden ceiling in the Vyborg Library

    DEFF Research Database (Denmark)

    Mortensen, Bo

    2004-01-01

    Much has been written about the Undulating Ceiling at the lecture hall of the Vyborg Library. Alvar Aalto himself claimed the ceiling to be "ninety-nine per cent acoustically perfect" and the sketches showing the acoustical considerations behind the ceiling-design is often reproduced. But how did...

  3. ENERGY STAR Certified Ceiling Fans

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.1 ENERGY STAR Program Requirements for Ceiling Fans that are effective as of April 1,...

  4. Diffuse Ceiling Inlet Systems and the Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Rong, Li

    2010-01-01

    A diffuse ceiling inlet system is an air distribution system which is supplying the air through the whole ceiling. The system can remove a large heat load without creating draught in the room. The paper describes measurements in the case of both cooling and heating, and CFD predictions are given...

  5. Does the Glass Ceiling Exist? A Cross-National Perspective on

    OpenAIRE

    Gang, Ira N.; Landon-Lane, John S.; Yun, Myeong-Su

    2003-01-01

    We compare male and female upward labor income mobility in Germany and the United States using the GSOEP-PSID Cross National Equivalent File. Our main interest is to test whether a glass ceiling exists for women. The standard glass ceiling hypothesis highlights the belief that the playing field is level for women and men in the labor market up to a point, after which there is an effective limit on advancement for women. We examine the glass ceiling hypothesis by looking at the dynamics of the...

  6. Analysis of Rapidly Developing Low Cloud Ceilings in a Stable Environment

    Science.gov (United States)

    Bauman, William H., III; Barrett, Joe H., III; Case, Jonathan L.; Wheeler, Mark M.; Baggett, G. Wayne

    2006-01-01

    Forecasters at the Space Meteorology Group (SMG) issue 30 to 90 minute forecasts for low cloud ceilings at the Space Shuttle Landing Facility (TTS) to support Space Shuttle landings. Mission verification statistics have shown ceilings to be the number one forecast challenge for SMG. More specifically, forecasters at SMG are concerned with any rapidly developing clouds/ceilings below 8000 ft in a stable, capped thermodynamic environment. Therefore, the Applied Meteorology Unit (AMU) was tasked to examine archived events of rapid stable cloud formation resulting in ceilings below 8000 ft, and document the atmospheric regimes favoring this type of cloud development. The AMU examined the cool season months of November to March during the years of 1993-2003 for days that had low-level inversions and rapid, stable low cloud formation that resulted in ceilings violating the Space Shuttle Flight Rules. The AMU wrote and modified existing code to identify inversions from the morning (-10 UTC) Cape Canaveral, FL rawinsonde (XMR) during the cool season and output pertinent sounding information. They parsed all days with cloud ceilings below 8000 ft at TTS, forming a database of possible rapidly-developing low ceiling events. Days with precipitation or noticeable fog burn-off situations were excluded from the database. In the first phase of this work, only the daytime hours were examined for possible ceiling development events since low clouds are easier to diagnose with visible satellite imagery. Phase II of this work includes expanding the database to include nighttime cases which is underway as this abstract is being written. For the nighttime cases, the AMU will analyze both the 00 UTC soundings and the 10 UTC soundings to examine those data for the presence of a low-level inversion. The 00 UTC soundings will probably not have a surface-based inversion, but the presence of inversions or "neutral" layers aloft and below 8,000 ft will most likely help define the stable

  7. Evaluation of ceiling lifts: transfer time, patient comfort and staff perceptions.

    Science.gov (United States)

    Alamgir, Hasanat; Li, Olivia Wei; Yu, Shicheng; Gorman, Erin; Fast, Catherine; Kidd, Catherine

    2009-09-01

    Mechanical lifting devices have been developed to reduce healthcare worker injuries related to patient handling. The purpose of this study was to evaluate ceiling lifts in comparison to floor lifts based on transfer time, patient comfort and staff perceptions in three long-term care facilities with varying ceiling lift coverage. The time required to transfer or reposition patients along with patient comfort levels were recorded for 119 transfers. Transfers performed with ceiling lifts required on average less time (bed to chair transfers: 156.9 seconds for ceiling lift, 273.6 seconds for floor lift) and were found to be more comfortable for patients. In the three facilities, 143 healthcare workers were surveyed on their perceptions of patient handling tasks and equipment. For both transferring and repositioning tasks, staff preferred to use ceiling lifts and also found them to be less physically demanding. Further investigation is needed on repositioning tasks to ensure safe practice.

  8. Glass ceilings of professionalisation.

    Science.gov (United States)

    Stott, Dawn L

    2016-04-01

    The term glass ceiling is a political term often used to describe an unbreakable barrier that isnot visible with the human eye, but it keeps minorities from rising up i.e. it is a barrier to minoritygroups, in the past (and sometimes still) for women, that stops them from achieving theirtrue potential.

  9. Perceptions of the Glass Ceiling Effect in Community Colleges

    Science.gov (United States)

    Myers, Cheryl E.

    2010-01-01

    The purpose of this study was to determine the existence of a glass ceiling effect within community colleges by examining faculty, staff and administrator's perceptions of a glass ceiling as it relates to the advancement of women at their institutions. This was done by using a cross-sectional survey administered electronically to faculty, staff…

  10. Glass Ceiling in Academic Administration in Turkey: 1990s versus 2000s

    Science.gov (United States)

    Gunluk-Senesen, Gulay

    2009-01-01

    This paper assesses the glass ceiling for academics in the Turkish universities with reference to top administration positions: rectors and deans. Glass ceiling indicators show that the glass ceiling thickened from the 1990s to late 2000s. The findings are discussed against the background of the transformation in the Turkish universities in the…

  11. Solar passive ceiling system. Final report. [Passive solar heating system with venetian blind reflectors and latent heat storage in ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, A.R.

    1980-01-01

    The construction of a 1200 square foot building, with full basement, built to be used as a branch library in a rural area is described. The primary heating source is a passive solar system consisting of a south facing window system. The system consists of: a set of windows located in the south facing wall only, composed of double glazed units; a set of reflectors mounted in each window which reflects sunlight up to the ceiling (the reflectors are similar to venetian blinds); a storage area in the ceiling which absorbs the heat from the reflected sunlight and stores it in foil salt pouches laid in the ceiling; and an automated curtain which automatically covers and uncovers the south facing window system. The system is totally passive and uses no blowers, pumps or other active types of heat distribution equipment. The building contains a basement which is normally not heated, and the north facing wall is bermed four feet high around the north side.

  12. Multiprocessor Priority Ceiling Emulation for Safety-Critical Java

    DEFF Research Database (Denmark)

    Strøm, Torur Biskopstø; Schoeberl, Martin

    2015-01-01

    Priority ceiling emulation has preferable properties on uniprocessor systems, such as avoiding priority inversion and being deadlock free. This has made it a popular locking protocol. According to the safety-critical Java specication, priority ceiling emulation is a requirement for implementations....... However, implementing the protocol for multiprocessor systemsis more complex so implementations might perform worse than non-preemptive implementations. In this paper we compare two multiprocessor lock implementations with hardware support for the Java optimized processor: non-preemptive locking...

  13. Performance analysis of a new design of office diffuse ceiling ventilation system

    DEFF Research Database (Denmark)

    Fan, Jianhua; Hviid, Christian Anker; Yang, Honglu

    2013-01-01

    This paper aims to document and analyse performance of a new design of diffuse ceiling ventilation system in a typical office room. A full scale measurement is carried out in a climate chamber with an office setup at the Technical University of Denmark. Indoor air temperatures, air speeds, wall...... surface temperatures, pressure loss of the ceiling and ventilation effectiveness are measured for an air change rate of 3.5 h-1 and 5.1 h -1 respectively. A computational fluid dynamics model of the office with the diffuse ceiling ventilation system is built and validated by the full scale measurement....... The measurements of pressure loss across the ceiling show a low pressure drop between the plenum and the occupied zone. Ventilation effectiveness is measured to be close to 1 on average under the tested conditions. It is shown that the diffuse ceiling ventilation system is able to remove indoor pollutant...

  14. Air Distribution in Rooms with Ceiling-mounted Obstacles and Three-Dimensional Isothermal Flow

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Evensen, Louis; Grabau, Peter

    The air supply openings in ventilated rooms are often placed close to the ceiling. A recirculating flow is generated in the room, and the region between the ceiling and the occupied zone serves as an entrainment and velocity decay area for the wall jets. Ceiling-mounted obstacles may disturb...

  15. Ceiling art in a radiation therapy department: its effect on patient treatment experience

    International Nuclear Information System (INIS)

    Bonett, Jotham

    2015-01-01

    A new initiative has been implemented at the Sunshine Hospital Radiation Therapy Centre, to provide a calming and comforting environment for patients attending radiation therapy treatment. As part of this initiative, the department's computed tomography (CT) room and radiation therapy bunkers were designed to incorporate ceiling art that replicates a number of different visual scenes. The study was undertaken to determine if ceiling art in the radiation therapy treatment CT and treatment bunkers had an effect on a patient's experience during treatment at the department. Additionally, the study aimed to identify which of the visuals in the ceiling art were most preferred by patients. Patients were requested to complete a 12-question survey. The survey solicited a patient's opinion/perception on the unit's unique ceiling display with emphasis on aesthetic appeal, patient treatment experience and the patient's engagement due to the ceiling display. The responses were dichotomised to ‘positive’ or ‘negative’. Every sixth patient who completed the survey was invited to have a general face-to-face discussion to provide further information about their thoughts on the displays. The results demonstrate that the ceiling artwork solicited a positive reaction in 89.8% of patients surveyed. This score indicates that ceiling artwork contributed positively to patients’ experiences during radiation therapy treatment. The study suggests that ceiling artwork in the department has a positive effect on patient experience during their radiation therapy treatment at the department

  16. Ceiling art in a radiation therapy department: its effect on patient treatment experience

    Energy Technology Data Exchange (ETDEWEB)

    Bonett, Jotham [Sunshine Hospital Radiation Therapy Centre, Melbourne, Vic. (Australia)

    2015-09-15

    A new initiative has been implemented at the Sunshine Hospital Radiation Therapy Centre, to provide a calming and comforting environment for patients attending radiation therapy treatment. As part of this initiative, the department's computed tomography (CT) room and radiation therapy bunkers were designed to incorporate ceiling art that replicates a number of different visual scenes. The study was undertaken to determine if ceiling art in the radiation therapy treatment CT and treatment bunkers had an effect on a patient's experience during treatment at the department. Additionally, the study aimed to identify which of the visuals in the ceiling art were most preferred by patients. Patients were requested to complete a 12-question survey. The survey solicited a patient's opinion/perception on the unit's unique ceiling display with emphasis on aesthetic appeal, patient treatment experience and the patient's engagement due to the ceiling display. The responses were dichotomised to ‘positive’ or ‘negative’. Every sixth patient who completed the survey was invited to have a general face-to-face discussion to provide further information about their thoughts on the displays. The results demonstrate that the ceiling artwork solicited a positive reaction in 89.8% of patients surveyed. This score indicates that ceiling artwork contributed positively to patients’ experiences during radiation therapy treatment. The study suggests that ceiling artwork in the department has a positive effect on patient experience during their radiation therapy treatment at the department.

  17. Experimental study of perforated suspended ceilings as diffuse ventilation air inlets

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2013-01-01

    An experimental study is reported in this paper for a diffuse ceiling ventilation concept. The analyses were carried out with two different porous surfaces mounted in a suspended ceiling: perforated tiles of aluminium and of gypsum. Ventilation air was supplied above the suspended ceiling effecti...... surface which increases the potential and applicability of the concept. Risk of thermal discomfort was not disclosed but the study did show evidence of large fluctuating air movements which could stem from transient behaviour creating sensations of draught to the occupants....

  18. Hardware Locks with Priority Ceiling Emulation for a Java Chip-Multiprocessor

    DEFF Research Database (Denmark)

    Strøm, Torur Biskopstø; Schoeberl, Martin

    2015-01-01

    According to the safety-critical Java specification, priority ceiling emulation is a requirement for implementations, as it has preferable properties, such as avoiding priority inversion and being deadlock free on uni-core systems. In this paper we explore our hardware supported implementation...... of priority ceiling emulation on the multicore Java optimized processor, and compare it to the existing hardware locks on the Java optimized processor. We find that the additional overhead for priority ceiling emulation on a multicore processor is several times higher than simpler, non-premptive locks, mainly...

  19. Glass ceiling in SMEs? Women, managerialization and performance

    OpenAIRE

    L. Songini; L. Gnan

    2012-01-01

    This article analyses the role of women in a sample of Italian small and medium sized enterprises (SMEs), both non-family and family owned businesses. We assume that the existence of a glass ceiling implies that women are not in a position to exercise an active role in the company; ownership per se does not assure the elimination of the glass ceiling, while the broader involvement of women in governance and management roles, as we may suppose in family firms, may represent a better situation ...

  20. Home Insulation With the Stroke of a Brush

    Science.gov (United States)

    2003-01-01

    Hy-Tech Thermal Solutions, LLC, of Melbourne, Florida, is producing a very complex blend of ceramic vacuum-filled refractory products designed to minimize the path of hot air transfer through ceilings, walls, and roofs. The insulating ceramic technology blocks the transfer of heat outward when applied to paint on interior walls and ceilings, and prevents the transfer of heat inward when used to paint exterior walls and roofs, effectively providing year-round comfort in the home. As a manufacturer and marketer of thermal solutions for residential, commercial, and industrial applications, Hy-Tech Thermal Solutions attributes its success to the high performance insulating ceramic microsphere originally developed from NASA thermal research at Ames Research Center. Shaped like a hollow ball so small that it looks as if it is a single grain of flour to the naked eye (slightly thicker than a human hair), the microsphere is noncombustible and fairly chemical-resistant, and has a wall thickness about 1/10 of the sphere diameter, a compressive strength of about 4,000 pounds per square inch, and a softening point of about 1,800 C. Hy-Tech Thermal Solutions improved upon these properties by removing all of the gas inside and creating a vacuum. In effect, a 'mini thermos bottle' is produced, acting as a barrier to heat by reflecting it away from the protected surface. When these microspheres are combined with other materials, they enhance the thermal resistance of those materials. In bulk, the tiny ceramic 'beads' have the appearance of a fine talcum powder. Their inert, nontoxic properties allow them to mix easily into any type of paint, coating, adhesive, masonry, or drywall finish. Additionally, their roundness causes them to behave like ball bearings, rolling upon each other, and letting the coatings flow smoothly. When applied like paint to a wall or roof, the microsphere coating shrinks down tight and creates a dense film of the vacuum cells. The resulting ceramic layer

  1. Airborne fibre and asbestos concentrations in system built schools

    Science.gov (United States)

    Burdett, Garry; Cottrell, Steve; Taylor, Catherine

    2009-02-01

    This paper summarises the airborne fibre concentration data measured in system built schools that contained asbestos insulation board (AIB) enclosed in the support columns by a protective steel casing. The particular focus of this work was the CLASP (Consortium of Local Authorities Special Programme) system buildings. A variety of air monitoring tests were carried out to assess the potential for fibres to be released into the classroom. A peak release testing protocol was adopted that involved static sampling, while simulating direct impact disturbances to selected columns. This was carried out before remediation, after sealing gaps and holes in and around the casing visible in the room (i.e. below ceiling level) and additionally round the tops of the columns, which extended into the suspended ceiling void. Simulated and actual measurements of worker exposures were also undertaken, while sealing columns, carrying out cleaning and maintenance work in the ceiling voids. Routine analysis of these air samples was carried out by phase contrast microscopy (PCM) with a limited amount of analytical transmission electron microscopy (TEM) analysis to confirm whether the fibres visible by PCM were asbestos or non-asbestos. The PCM fibre concentrations data from the peak release tests showed that while direct releases of fibres to the room air can occur from gaps and holes in and around the column casings, sealing is an effective way of minimising releases to below the limit of quantification (0.01 f/ml) of the PCM method for some 95% of the tests carried out. Sealing with silicone filler and taping any gaps and seams visible on the column casing in the room, also gave concentrations below the limit of quantification (LOQ) of the PCM method for 95% of the tests carried out. The data available did not show any significant difference between the PCM fibre concentrations in the room air for columns that had or had not been sealed in the ceiling void, as well as in the room

  2. Airborne fibre and asbestos concentrations in system built schools

    International Nuclear Information System (INIS)

    Burdett, Garry; Cottrell, Steve; Taylor, Catherine

    2009-01-01

    This paper summarises the airborne fibre concentration data measured in system built schools that contained asbestos insulation board (AIB) enclosed in the support columns by a protective steel casing. The particular focus of this work was the CLASP (Consortium of Local Authorities Special Programme) system buildings. A variety of air monitoring tests were carried out to assess the potential for fibres to be released into the classroom. A peak release testing protocol was adopted that involved static sampling, while simulating direct impact disturbances to selected columns. This was carried out before remediation, after sealing gaps and holes in and around the casing visible in the room (i.e. below ceiling level) and additionally round the tops of the columns, which extended into the suspended ceiling void. Simulated and actual measurements of worker exposures were also undertaken, while sealing columns, carrying out cleaning and maintenance work in the ceiling voids. Routine analysis of these air samples was carried out by phase contrast microscopy (PCM) with a limited amount of analytical transmission electron microscopy (TEM) analysis to confirm whether the fibres visible by PCM were asbestos or non-asbestos. The PCM fibre concentrations data from the peak release tests showed that while direct releases of fibres to the room air can occur from gaps and holes in and around the column casings, sealing is an effective way of minimising releases to below the limit of quantification (0.01 f/ml) of the PCM method for some 95% of the tests carried out. Sealing with silicone filler and taping any gaps and seams visible on the column casing in the room, also gave concentrations below the limit of quantification (LOQ) of the PCM method for 95% of the tests carried out. The data available did not show any significant difference between the PCM fibre concentrations in the room air for columns that had or had not been sealed in the ceiling void, as well as in the room

  3. Parametrical analysis on the diffuse ceiling ventilation by experimental and numerical studies

    DEFF Research Database (Denmark)

    Zhang, Chen; Kristensen, Martin Heine; Jensen, Jakob Sølund

    2016-01-01

    This paper aims to investigate the performance of diffuse ceiling ventilation in a classroom. An experimental study is carried out in a test chamber to examine the impact of diffuse ceiling opening area on the system cooling capacity and thermal comfort. The results indicate that diffuse ceiling ....... The numerical results reveal that even distribution of heat sources gives a lower draught risk environment than centralized distribution. In addition, there is a significant increase on the draught risk with increase of room height....

  4. Human Response to Personalized Ventilation Combined with Chilled Ceiling

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Marcol, Bartosz

    2014-01-01

    Personalized ventilation (PV) improves inhaled air quality, because it provides fresh air to each workstation and directly to occupant’s breathing zone. Previous research was focused on combining PV with additional total volume air distribution, i.e. mixing ventilation or displacement ventilation......, the use of radiant ceiling cooling will provide operative temperature lower than the air temperature and will improve further occupants’ thermal comfort at warm environment. Therefore combining PV with chilled ceiling may be an effective way to provide thermal comfort in rooms at temperature higher than...... temperature for chilled ceiling was 15,5/16,8°C at room air temperature of 26°C and 19,5/20,6°C at 28°C. During the experiment the subjects were performing typical office tasks at workstations with computers. Exposure included also increased activity level office work for a period of 25 min...

  5. The effect of diffuse ceiling panel on the energy performance of thermally activated building construction

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2016-01-01

    An integrated system combining diffuse ceiling ventilation with thermally activated building construction (TABS) was proposed recently. In this system, TABS is encapsulated by diffuse ceiling panel and cannot have directly heat exchange with the room. The aim of this study is to investigate...... the effect of diffuse ceiling panel on the energy performance of TABS in both heat and cooling mode. Experiments are carried out in a full-scale test facility with the integrated system, and the cases without diffuse ceiling are also measured as references. The results indicate that the diffuse ceiling has...... an opposite effect on the heating and cooling capacity of TABS. In addition, a numerical model is built and validated by the measured data. The validated model is further applied to conduct a paramedical study on the materials of the diffuse ceiling panel....

  6. Transparent thermal insulation for prefabricated school buildings; Einsatz transparenter Waermedaemmung an Schulgebaeuden in praefabrizierter Bauweise

    Energy Technology Data Exchange (ETDEWEB)

    Russ, C. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany). Gruppe Solares Bauen; Buchmann, R. [Leipzigprojekt GmbH, Leipzig (Germany); Duesterhoeft, A. [Holz- und Leichtmetallbau GmbH, Leipzig (Germany)

    1997-12-31

    The existing schools in the new federal states built from prefabricated elements need to be modernized in order to reduce their energy demand. Fitting some 300 square metres of transparent thermal insulation to the south side of a house front may lead to a cut in its thermal energy demand by 74 per cent. This energy consumption is by 12 kWh per square metre lower than the one obtained with opaque thermal insulation. The results of the first demonstration project are described. (MSK) [Deutsch] Die in den neuen Bundeslaendern vorhandenen Schulen in vorgefertigter Bauweise sind energetisch sanierungsbeduerftig. Werden im Rahmen einer Sanierung ca. 300qm transparente Waermedaemmung an der suedorientierten Fassade eingesetzt, so kann der Heizwaermebedarf um 74% herabgesetzt werden. Das sind 12 kWh/qm weniger als bei dem vergleichsweisen Einsatz einer opaken Waermedaemmung. Im Folgenden werden die Ergebnisse des ersten Demonstrationsprojekts beschrieben.

  7. Analisa Persepsi Glass Ceiling Pada Grup Hotel Accor Di Surabaya

    OpenAIRE

    Hariono, Ardhi Ananta Kurnia; Theios, Jefson

    2017-01-01

    Tujuan dilakukannya penelitian ini adalah untuk mengetahui persepsi karyawan perempuan akan glass ceiling pada grup hotel Accor Surabaya melalui hambatan pribadi, hambatan situasional, dan hambatan sosial. Penelitian ini di fokuskan pada kelompok umur dan status pernikahan. Metode pengumpulan data menggunakan survei kepada 50 karyawan perempuan yang mejabat pada posisi manajerial di grup Hotel Accor Surabaya. Hasil penelitian menunjukkan persepsi glass ceiling pada interval kecil. Untuk kelom...

  8. "No Ceiling on Achievement": Breaking the Glass Ceiling or Hitting a Steel Plate in Urban Schools?

    Science.gov (United States)

    Firth, Ben; Melia, Victoria; Bergan, Dave; Whitby, Lisa

    2014-01-01

    This article, written by a team of research-active teachers who are also senior leaders in a large, urban, comprehensive high school in the North of England, reports on their joint teacher inquiry project. This work has school-wide significance, given recent history, progressing from being graded as a "failing" school by the Office for…

  9. Effect of Number of Blades on Performance of Ceiling Fans

    Directory of Open Access Journals (Sweden)

    Adeeb Ehsan

    2015-01-01

    Full Text Available In this paper, the effect of number of blades on ceiling fan performance is discussed. This approach helps to satisfy tradeoff between high air flow (performance and power consumption (energy efficiency. Specifically, variation from two to six blades is considered with nonlinear forward sweep profile. Reynolds Averaged Navier-Stokes (RANS technique is used to model the flow field induced by the ceiling fan inside a generic room. The performance is gauged through response parameters namely volumetric flow rate, mass flow rate, torque and energy efficiency. The results indicate that mass and volumetric flow rates are maximized for six blade configuration and energy efficiency is maximized for two blade configuration. The study indicates the importance of tradeoff between high air flow through ceiling fan and associated energy efficiency.

  10. Do Asian American Faculty Face a Glass Ceiling in Higher Education?

    Science.gov (United States)

    Lee, Sharon M.

    2002-01-01

    Evaluated the glass ceiling hypothesis in relation to Asian American faculty using data from the 1993 National Study of Post-Secondary Faculty for 1,019 Asian American faculty members. Data limitations prevent concluding that such faculty do or do not face a glass ceiling; however, baseline findings for future research are established. (SLD)

  11. Numerical Prediction of Airflow in a Room with Ceiling-Mounted Obstacles

    DEFF Research Database (Denmark)

    Svidt, Kjeld

    In ventilated rooms the air inlet device is often placed close to the ceiling. The air inlet will form a wall jet or a reattached wall jet. The wall jet may be disturbed by ceilingmounted obstacles such as light fittings or ceiling beams which, in some cases, can cause the air jet to be deflected...

  12. Comparative Analysis of Houses Built from Insulating Concrete Formwork – case Study

    Directory of Open Access Journals (Sweden)

    Mačková Daniela

    2015-11-01

    Full Text Available More and more, people are looking to build and live in different ways. They want houses with a high standard of living and reasonable production and maintenance costs. However, they also want to build a way that does not adversely affect their quality of life. Currently, the using of modern methods of construction (MMC expands consistently year on year. MMC include prefabricated products made in the factory and also new methods of building that are site-based and they are regarded as a means of achieving higher quality, reducing time spent onsite, increasing safety and overcoming skills shortages in the industry. Aim of this paper is to analyze and compare, trough case study, technical, cost and technological parameters of house built by modern method of construction (from insulating concrete formwork and by traditional method (from brick system. The subject of case study is house modeled in two variants of insulating concrete formwork and a variant bricks and ceiling system. In conclusion, there is selected optimal method and system for house construction through multicriteria optimization.

  13. An Efficient Ceiling-view SLAM Using Relational Constraints Between Landmarks

    Directory of Open Access Journals (Sweden)

    Hyukdoo Choi

    2014-01-01

    Full Text Available In this paper, we present a new indoor 'simultaneous localization and mapping‘ (SLAM technique based on an upward-looking ceiling camera. Adapted from our previous work [17], the proposed method employs sparsely-distributed line and point landmarks in an indoor environment to aid with data association and reduce extended Kalman filter computation as compared with earlier techniques. Further, the proposed method exploits geometric relationships between the two types of landmarks to provide added information about the environment. This geometric information is measured with an upward-looking ceiling camera and is used as a constraint in Kalman filtering. The performance of the proposed ceiling-view (CV SLAM is demonstrated through simulations and experiments. The proposed method performs localization and mapping more accurately than those methods that use the two types of landmarks without taking into account their relative geometries.

  14. Diffuse Ceiling Ventilation and the Influence of Room Height and Heat Load Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Vilsbøll, Rasmus W; Liu, Li

    2015-01-01

    Diffuse ceiling (inlet) ventilation is an air distribution system that supplies air from the entire ceiling surface, giving a low supply velocity. The flow pattern in the room is controlled by the heat sources. The system generates high mixing flow and the air velocities in the room are expected...... to be not much influenced by the flow rate to the room but dependent on the heat load. Previous studies have shown that diffuse ceiling ventilation has an ability to remove large heat loads without compromising the indoor climate. However, recent experiments indicate that the maximum accepted heat load decreases...... with a large room height and it decreases in connection with certain heat load distributions. Room geometries and heat load distributions that are optimal for diffuse ceiling ventilation are discussed. A simplified design procedure is introduced....

  15. Does the Glass Ceiling Exist?: A Cross-National Perspective on Gender Income Mobility

    OpenAIRE

    Ira N. Gang; John Landon-Lane; Myeong-Su Yun

    2003-01-01

    We compare male and female upward labor income mobility in Germany and the United States using the GSOEP-PSID Cross-National Equivalent File. Our main interest is to test whether a glass ceiling exists for women. Conventional thinking about the glass ceiling highlights the belief that the playing field is level for women and men in the labor market up to a certain point, after which there is an effective limit on advancement for women. We examine the glass ceiling hypothesis by looking at the...

  16. Women's Career Development at the Glass Ceiling.

    Science.gov (United States)

    Inman, Pamela L.

    1998-01-01

    For women, success in shattering the glass ceiling lies not in adapting to a male workplace culture but in using career strategies such as self-knowledge, multiple mentors, integration of body and soul, and fluid, customized careers. (SK)

  17. Evaluation of environmental and physiological factors of a whole ceiling-type air conditioner using a salivary biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yusuke; Yamaguchi, Masaki [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Morito, Naomi; Nishimiya, Hajime; Yamagishi, Hideyuki [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2009-06-15

    In order to improve environmental condition such as humidity and airflow in living spaces, a whole ceiling-type air conditioner is proposed. This novel air conditioner exhaust dispersed airflow from the whole ceiling by using a 3-dimensional knit fabric. The purpose of this paper is to reveal the effects when controlling humidity and airflow using the whole ceiling-type air conditioner compared to a commercialized concentrated exhaust air conditioner (normal-type air conditioner) under the same temperature. Salivary {alpha}-amylase activity (SAA) was used as an index of sympathetic nervous activity. An acute experiment for a 15 min period was conducted using 12 healthy young female adults. No significant differences in room and skin temperatures were observed between the whole ceiling-type air conditioner and the normal-type air conditioner. The whole ceiling-type air conditioner showed 11.1% lower humidity than the normal-type air conditioner. The whole ceiling-type air conditioner showed one-thirteenth the airflow of the normal-type air conditioner. As a result, the PMV of the whole ceiling-type air conditioner was more comfortable level than the normal one. Moreover, subjective evaluation questionnaire revealed a significant difference was observed in wind perception (windy). The SAA of subjects under the whole ceiling-type air conditioner showed significantly low values compared with the normal-type air conditioner. It was found that the subject's sympathetic nervous activity has been inactivated under the conditions of the whole ceiling-type air conditioner. Thus, it was revealed that the whole ceiling-type air conditioner provides a more comfortable air environment by reducing physical stimulations to humans. (author)

  18. The Real Glass Ceiling. Your Career.

    Science.gov (United States)

    Savage, Adrian

    2002-01-01

    There is a powerful and common glass ceiling (barrier that prevents capable employees from being promoted) that affects men as much as women. Between middle management and the executive level, corporate culture shifts to one based on power and a worker must play by new rules even if these have never been explained. (JOW)

  19. The effect of low ceiling on the external combustion of the cabin fire

    Science.gov (United States)

    Su, Shichuan; Chen, Changyun; Wang, Liang; Wei, Chengyin; Cui, Haibing; Guo, Chengyu

    2018-06-01

    External combustion is a phenomenon where the flame flares out of the window and burns outside. Because of the particularity of the ship's cabin structure, there is a great danger in the external combustion. In this paper, the numerical calculation and analysis of three kinds of low ceiling ship cabin fire are analyzed based on the large eddy numerical simulation technique. Through the analysis of temperature, flue gas velocity, heat flux density and so on, the external combustion phenomenon of fire development is calculated. The results show that when external combustion occurs, the amount of fuel escaping decreases with the roof height. The temperature above the window increases with the height of the ceiling. The heat flux density in the external combustion flame is mainly provided by radiation, and convection is only a small part; In the plume area there is a time period, in this time period, the convective heat flux density is greater than the radiation heat flux, this time with the ceiling height increases. No matter which ceiling height, the external combustion will seriously damage the structure of the ship after a certain period of time. The velocity distribution of the three roof is similar, but with the height of the ceiling, the area size is also increasing.

  20. Seville City Hall Chapter Room ceiling decoration

    Directory of Open Access Journals (Sweden)

    Robador, M. D.

    2010-02-01

    Full Text Available The present article describes a chemical and physical study of the colour, chemical composition and mineral phases of the decorative materials in the Seville City Hall Chapter House ceiling. The findings showed that the inner most layer of material, calcite, was covered with white lead, in turn concealed under a layer of gilded bole. The ceiling underwent re-gilding, also over bole, due in all likelihood to wear on the original gold leaf. In the nineteenth century, the entire ceiling with the exception of the inscriptions was whitewashed with calcite and white lead. Silver was employed on King John I’s sword (coffer 27. Gold leaf was used to adorn the royal attributes: crowns, belts, sceptres, swords and rosary beads. The high reliefs were likewise gilded. The pigments identified on the ceiling adornments included azurite, malachite, vermilion and gas black. A lime and ground dolomite mortar was used throughout.

    El objetivo de este trabajo es el estudio de diferentes aspectos, como el color, la composición química y las fases mineralógicas presentes en los diferentes materiales que forman la ornamentación del techo de la Sala Capitular del Ayuntamiento de Sevilla, mediante métodos físicos y químicos. Nuestros resultados muestran que el dorado fue realizado sobre una capa de bol previamente depositada sobre una lámina de blanco de plomo que cubría un estrato de calcita. Posteriormente, y probablemente debido a alteraciones en el dorado original, el techo fue de nuevo dorado usando una técnica similar. En el siglo XIX, casi todo el techo, excepto las zonas con inscripciones, fue blanqueado usando una mezcla de calcita y blanco de plomo. Se empleó plata para cubrir la espada del rey Juan I (casetón 27. Finísimas láminas de oro se usaron para decorar los atributos reales: coronas, cinturones, cetros, espadas y rosarios. En diferentes partes de la decoración fueron detectados pigmentos como azurita, malaquita, bermellón y

  1. Comparative experimental and numerical studies of usual insulation materials and PCMs in buildings at Casablanca

    Science.gov (United States)

    Mourid, Amina; El Alami, Mustapha

    2018-05-01

    In this paper, we present a comparative thermal study of the usual insulation materials used in the building as well as the innovate one like phase change materials (PCMs). Both experimental study and numerical approach were applied in this work for summer season. In the experimental study the PCM was installed on the outer surface on the ceiling of one of two full-scale rooms located at FSAC, Casablanca. A simulation model was performed with TRNSYS’17 software. We have established as a criterion of comparison the internal temperatures. An economic study also has been carried out. Based on this latter, that the PCM is most efficient.

  2. Modeling of a hydronic ceiling system and its environment as energetic auditing tool

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca Diaz, Nestor [Universidad Tecnologica de Pereira, Facultad de Ingenieria Mecanica (Colombia); University of Liege Belgium, Thermodynamics Laboratory Campus du Sart Tilman - Bat: B49 - P33, B-4000 Liege (Belgium)

    2011-03-15

    As a part of a commissioning study, the chilled ceiling system of a large commercial building located in Belgium is evaluated. A representative office has been instrumented and data on the chilled ceiling system operating in real conditions have been collected. The simulation of the whole system is performed by means of a transient thermal model of the building and its HVAC system. The model considers the hydronic panels as a transient-state finned heat exchanger connected to a simplified lumped transient model of the building. The behavior of the hydronic ceiling system and the interactions with its environment (walls, ventilated facade, internal loads and ventilation system) has been experimentally and numerically evaluated. Commissioning test results show that the influence of surfaces temperatures inside the room, especially the facade, is considerable. Then, it is clear that the hydronic ceiling system must be evaluated together with its designed environment and not as a separate HVAC equipment. (author)

  3. Performance of personalized ventilation combined with chilled ceiling in an office room: inhaled air quality and contaminant distribution

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    people (exhaled air, bioeffluents) and building materials (wall painting). Personalized ventilation combined with chilled ceiling ensured highest air quality at the workstation under all conditions. Pollutant concentration in the occupied zone away from the workstations did not differ substantially...... between the tested systems. Chilled ceiling combined with personalized ventilation working as the only air supplying system may be optimal solution in many buildings.......In a simulated two persons’ office room inhaled air quality and contaminant distribution provided with personalized ventilation combined with chilled ceiling, mixing ventilation only, chilled ceiling with mixing ventilation and chilled ceiling with mixing and personalized ventilation was studied...

  4. Final report development of a regional nitrogen ceiling; Eindrapportage ontwikkeling regionaal stikstofplafond

    Energy Technology Data Exchange (ETDEWEB)

    Bleeker, A.; Hensen, A. [ECN Environment and Energy Engineering, Petten (Netherlands); Rougoor, C. [Centrum voor Landbouw en Milieu CLM, Culemborg (Netherlands)

    2013-01-15

    The development of a methodology in which integrated nitrogen ceilings can be studied on a regional level is described. Next to the agricultural sector, also other sectors are taken into consideration (traffic, industry, etc.) with respect to the development of the nitrogen ceiling methodology. The study consists of two parts: the feasibility of a nitrogen ceiling system and the actual development of such a system [Dutch] Deze rapportage beschrijft de ontwikkeling van een methodiek waarbij integrale stikstofplafonds op gebiedsniveau kunnen worden bestudeerd. Dit onderzoek beschouwt, naast landbouw, ook andere sectoren (verkeer, industrie, etc.) voor het ontwikkelen van de stikstofplafond methodiek. Het onderzoek bestaat uit twee onderdelen: bestuderen van de haalbaarheid van een stikstofplafond systematiek en het feitelijke ontwikkelen van een dergelijke systematiek.

  5. Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    vertical air temperature differences and air velocities for different hybrid systems are less than 3 C and 0.2 m/s when supply air temperature is 19 C, air change rate is 4.2 h-1, and heated surface temperature of floor/ceiling heating system is 25 C. Ventilation effectiveness of mixing ventilation system...... combined with floor/ceiling heating systems is approximately equal to 1.0, and ventilation effectiveness of displacement ventilation system combined with floor/ceiling heating systems ranges from 1.0 to 1.2. The floor/ceiling heating systems combined with mixing ventilation system have more uniform indoor...... air distribution but smaller ventilation effectiveness compared with the floor/ceiling heating systems combined with displacement ventilation system. With regard to the building heat loss increased by non-uniform indoor air distribution and small ventilation effectiveness, there should be an optimal...

  6. A Research on Glass Ceiling Syndrome Career Barriers of Women Academics

    OpenAIRE

    Serdar Öge; Alpay Karasoy; Özlem Kara

    2014-01-01

    Although women have merit in their jobs, they still are located very few in the top management in many sectors. There are many causes of such situation. Such a situation creates obstacles; especially invisible ones are called “glass ceiling syndrome”. Also, studies which handle this subject in academic community are very few. The aim of this research is to reach the results about glass ceiling obstacles in terms of female teaching staff (academics) working in higher educa...

  7. Future-proofing the environmental performance of low-income housing: a South African case study

    CSIR Research Space (South Africa)

    Ampofo-Anti, NL

    2012-09-01

    Full Text Available on stabilised fill ? Superstructure: Modular, hollow concrete blocks; and precast concrete window frames (applied to four out of seven windows to minimise thermal bridging). ? Finishes: Insulated ceiling board; and thermal plaster to external walls Three... performance of CH: ? Appropriate north-south orientation; ? Appropriate roof overhang combined with north-facing windows; ? Cavity walls (modular, hollow concrete blocks); ? Insulated ceiling; and ? Insulated external walls (thermal plaster). The study...

  8. Piercing the sovereign ceiling: Issues in oil and gas project financing

    International Nuclear Information System (INIS)

    Coleman, T.S.

    1998-01-01

    In the oil and gas sector, corporations and governments face huge capital spending requirements in order to transform large resource discoveries into producing, cash-generating assets. A significant portion of this funding is expected to be done on a project finance basis, where bank lenders or bond investors take a secured position in financing a discrete project, with the expectation of being paid back by the cash flows from that project after completion. This trend is increasing demand for crediting rating services to provide credit ratings for these project financings. A key challenge is to analyze and rate credit-worthy projects in countries that have relatively low foreign currency sovereign ceilings due to economic, political, and financial risks. In most cases, the credit ratings for projects financed in currencies outside the host country are capped at the country''s foreign currency ceiling. However, in a few instances, mainly in the oil and gas sector, Moody''s has pierced the foreign currency ceiling or rated certain projects above the sovereign ratings of the countries where they are domiciled. The purpose of this article is to briefly explain some of the qualitative factors and considerations that have allowed Moody''s to pierce the ceiling in the oil and gas sector, with a focus on two recent and noteworthy projects: Ras Laffan Liquefied Natural Gas in Qatar and Petrozuata in Venezuela

  9. Pipelines of Progress: An Update on the Glass Ceiling Initiative. A Status Report.

    Science.gov (United States)

    Department of Labor, Washington, DC.

    The "glass ceiling" refers to those barriers that have prevented the advancement of women and minorities into the top levels of executive management in major U.S. corporations. In 1991, the U.S. Department of Labor released a report describing the Glass Ceiling Initiative. This document reports on what occurred in the year following the…

  10. Window screening, ceilings and closed eaves as sustainable ways to control malaria in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Chaki Prosper P

    2009-09-01

    Full Text Available Abstract Background Malaria transmission in Africa occurs predominantly inside houses where the primary vectors prefer to feed. Human preference and investment in blocking of specific entry points for mosquitoes into houses was evaluated and compared with known entry point preferences of the mosquitoes themselves. Methods Cross-sectional household surveys were conducted in urban Dar es Salaam, Tanzania to estimate usage levels of available options for house proofing against mosquito entry, namely window screens, ceilings and blocking of eaves. These surveys also enabled evaluation of household expenditure on screens and ceilings and the motivation behind their installation. Results Over three quarters (82.8% of the 579 houses surveyed in Dar es Salaam had window screens, while almost half (48.9% had ceilings. Prevention of mosquito entry was cited as a reason for installation of window screens and ceilings by 91.4% (394/431 and 55.7% (127/228 of respondents, respectively, but prevention of malaria was rarely cited (4.3%, 22/508. The median cost of window screens was between US $ 21-30 while that of ceilings was between US $301-400. The market value of insecticide-treated nets, window screening and ceilings currently in use in the city was estimated as 2, 5 and 42 million US$. More than three quarters of the respondents that lacked them said it was too expensive to install ceilings (82.2% or window screens (75.5%. Conclusion High coverage and spending on screens and ceilings implies that these techniques are highly acceptable and excellent uptake can be achieved in urban settings like Dar es Salaam. Effective models for promotion and subsidization should be developed and evaluated, particularly for installation of ceilings that prevent entry via the eaves, which are the most important entry point for mosquitoes that cause malaria, a variety of neglected tropical diseases and the nuisance which motivates uptake.

  11. 2D and 3D GPR imaging of structural ceilings in historic and existing constructions

    Science.gov (United States)

    Colla, Camilla

    2014-05-01

    GPR applications in civil engineering are to date quite diversified. With respect to civil constructions and monumental buildings, detection of voids, cavities, layering in structural elements, variation of geometry, of moisture content, of materials, areas of decay, defects, cracks have been reported in timber, concrete and masonry elements. Nonetheless, many more fields of investigation remain unexplored. This contribution gives an account of a variety of examples of structural ceilings investigation by GPR radar in reflection mode, either as 2D or 3D data acquisition and visualisation. Ceilings have a pre-eminent role in buildings as they contribute to a good structural behaviour of the construction. Primarily, the following functions can be listed for ceilings: a) they carry vertical dead and live loads on floors and distribute such loads to the vertical walls; b) they oppose to external horizontal forces such as wind loads and earthquakes helping to transfer such forces from the loaded element to the other walls; c) they contribute to create the box skeleton and behaviour of a building, connecting the different load bearing walls and reducing the slenderness and flexural instability of such walls. Therefore, knowing how ceilings are made in specific buildings is of paramount importance for architects and structural engineers. According to the type of building and age of construction, ceilings may present very different solutions and materials. Moreover, in existing constructions, ceilings may have been substituted, modified or strengthened due to material decay or to change of use of the building. These alterations may often go unrecorded in technical documentation or technical drawings may be unavailable. In many cases, the position, orientation and number of the load carrying elements in ceilings may be hidden or not be in sight, due for example to the presence of false ceilings or to technical plants. GPR radar can constitute a very useful tool for

  12. Control of the dew point for refreshing ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Abrach, R.; Nitz, T.

    1996-03-01

    The functioning of a refreshing ceiling, delivered in water, needs a global regulation which must take in consideration, the local, the building and its environment. Then efficiency and energy and investments economy are optimized. 11 figs., 3 tabs.

  13. Effects of a thermal ceiling on postoperative hypothermia

    DEFF Research Database (Denmark)

    Henneberg, S; Eklund, A; Joachimsson, P O

    1985-01-01

    postoperatively with or without external heating from a heating ceiling. Central and peripheral temperatures, oxygen consumption, plasma catecholamines and shivering were measured. A method for continuous measurement of oxygen consumption and carbon dioxide production during spontaneous breathing is described...

  14. Ouch! Or ESL and the Glass Ceiling.

    Science.gov (United States)

    Migliacci, Naomi

    The realities of the glass ceiling, which prevents qualified women, minorities, and many English-as-a-Second-Language (ESL) students from advancement and promotion, are rarely discussed in English for Special Purposes (ESP)/ESL programs and courses. This paper explores the barriers to success, focusing on the sociolinguistic factors of verbal and…

  15. Glass Ceiling for Women in Higher Education.

    Science.gov (United States)

    Schedler, Petra; Glastra, Folke; Hake, Barry

    2003-01-01

    Discusses the place of women in higher education in the Netherlands. Suggests that it is not a question of numbers but of orientation, field, and the glass ceiling. Asserts that despite some improvement, higher education may be one of the last bastions against the recognition of women's worth. (Contains 42 references.) (JOW)

  16. THE IMPACT OF ORGANIZATIONAL STRUCTURE ON GLASS CEILING: AEGEAN REGION AGENCIES IN TURKEY

    OpenAIRE

    İNEL, Merve; GARAYEV, Vener; BAKAY, Aziz

    2014-01-01

    This study examined the relationship between organizationalstructure (mechanistic/organic) and glass ceiling, the concept known asnegative discrimination against women in workplace. The data collected fromrandomly selected 81 organizations in Aegean Region of Turkey was analyzedthrough hierarchical stepwise multiple regression. The results of the finalregression model suggest that glass ceiling is not dependent on organizationalstructure, while the control variable gender has a negative relat...

  17. A Modest Manifesto for Shattering the Glass Ceiling.

    Science.gov (United States)

    Meyerson, Debra E.; Fletcher, Joyce K.

    2000-01-01

    Approaches to the glass ceiling--encouraging women to adopt "masculine" attributes, accommodating women's unique needs, or celebrating women's differences--have shortcomings. A fourth approach links equity and effectiveness. "Small wins" recognizes that gender inequity is rooted in cultural patterns and uses small initiatives…

  18. The Perception of 'Glass Ceiling' and its Impact on Career Progression of Female Managers in Malaysia

    OpenAIRE

    Khan, Maria

    2013-01-01

    The glass ceiling is a transparent barrier that prevents women and minorities from moving up in the management hierarchy. Glass ceiling researchers have attempted to determine whether a glass ceiling exists by examining the actual promotion decision to top management, the percentage of management positions held by women in an organization, salary of male versus female managers, and ratings of potential promotion candidates to top management. The aim of this research is to investigate the vari...

  19. Character-Defining Features of Contributing Buildings and Structures in the Fort Gordon, Georgia, Signal School Campus Historic District

    Science.gov (United States)

    2016-07-01

    aluminum and plate- glass doors, sidelights, and transoms [right] (ERDC-CERL, 2015). .................. 178 Figure 243. Ceiling -mounted light fixture...Light pattern” effect on wall The typical Signal School building is of cast-in-place concrete columns with a waffle floor/ ceiling structure. The...would have a significant effect on the character-defining feature of the classroom hall- ways as would installing a dropped ceiling to cover the

  20. Smoke flow temperature beneath tunnel ceiling for train fire at subway station: Reduced-scale experiments and correlations

    International Nuclear Information System (INIS)

    Meng, Na; Wang, Qiang; Liu, Zhaoxia; Li, Xiao; Yang, He

    2017-01-01

    Highlights: • Reduced-scale experiments on train fire at subway station. • Smoke flow temperature beneath tunnel ceiling measured and correlated. • Effect of platform-tunnel conjunction door type on smoke temperature is clarified. - Abstract: This paper is to investigate the smoke flow temperature beneath tunnel ceiling for a train on fire stopping besides a subway station. Experiments were carried out in a reduced-scale (1:10) subway station model to study the maximum smoke temperature and the longitudinal temperature distribution beneath the tunnel ceiling by considering platform-tunnel conjunction doors of two types: the full-seal platform screen door (PSD) and the full-height safety door. For the maximum temperature beneath the tunnel ceiling, it is found to be well correlated non-dimensionally with heat release rate by a 3.65 and a 2.92 power law function for the full-seal platform screen door and the full-height safety door, respectively. For the longitudinal temperature distribution along the tunnel ceiling, it can be well correlated by an exponential function for both types of platform-tunnel conjunction doors. Concerning the effect of the door type, the maximum temperature is lower and the longitudinal temperature decays faster for full-height safety door than that for full-seal PSD. This is due to that with the full-height safety door, the effective width of the tunnel ceiling is widened, which results in more heat losses from the smoke flow to the ceiling.

  1. Demonstration of an advanced solar garden with a water ceiling. Final technical report, July 1, 1979-June 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Maes, R.; Riseng, C.; Thomas, G.; Mandeville, M.

    1980-09-01

    A history of the solar garden with the addition of the transparent water ceiling is presented, and a statement of the overall goals of the program is given. The objectives of the water ceiling grant are detailed. The rationale of the transparent water ceiling is developed and its implementation in the solar garden is described. The experimental procedures for evaluating the water ceiling as an integral part of an ongoing garden agricultural experiment are discussed and the results presented. The water ceiling has proven useful in providing extra thermal capacity to the solar garden. It provides heat at night after the water has been warmed during the day and retards overheating in the daytime by absorbing infrared energy into the water. In growing non-flowering plants, such as lettuce and Chinese cabbage, the water ceiling showed no noticeable degradation in yield or maturation rate. In flowering plants, such as tomatoes, the reduced light levels delayed yields by a couple of weeks but the total yield was only slightly diminished. In geographic areas where there is less cloud cover than in Michigan the water ceiling could be much more effective.

  2. A Literature Review of Sealed and Insulated Attics—Thermal, Moisture and Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Levinson, Ronnen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    In this literature review and analysis, we focus on the thermal, moisture and energy performance of sealed and insulated attics in California climates. Thermal. Sealed and insulated attics are expected to maintain attic air temperatures that are similar to those in the house within +/- 10°F. Thermal stress on the assembly, namely high shingle and sheathing temperatures, are of minimal concern. In the past, many sealed and insulated attics were constructed with insufficient insulation levels (~R-20) and with too much air leakage to outside, leading to poor thermal performance. To ensure high performance, sealed and insulated attics in new California homes should be insulated at levels at least equivalent to the flat ceiling requirements in the code, and attic envelopes and ducts should be airtight. We expect that duct systems in well-constructed sealed and insulated attics should have less than 2% HVAC system leakage to outside. Moisture. Moisture risk in sealed and insulated California attics will increase with colder climate regions and more humid outside air in marine zones. Risk is considered low in the hot-dry, highly populated regions of the state, where most new home construction occurs. Indoor humidity levels should be controlled by following code requirements for continuous whole-house ventilation and local exhaust. Pending development of further guidance, we recommend that the air impermeable insulation requirements of the International Residential Code (2012) be used, as they vary with IECC climate region and roof finish. Energy. Sealed and insulated attics provide energy benefits only if HVAC equipment is located in the attic volume, and the benefits depend strongly on the insulation and airtightness of the attic and ducts. Existing homes with leaky, uninsulated ducts in the attic should have major savings. When compared with modern, airtight duct systems in a vented attic, sealed and insulated attics in California may still provide substantial benefit

  3. The glass ceiling of corporate social responsibility : Consequences of a business case approach towards CSR

    NARCIS (Netherlands)

    Nijhof, A.H.J.; Jeurissen, R.J.M.

    2010-01-01

    Purpose – This paper aims to clarify that corporate social responsibility (CSR) has come a long way by the prevailing business case approach, but increasingly hits a glass ceiling. The glass ceiling metaphor refers to the inherent limitations created by a business case approach towards CSR.

  4. Individually controlled localized chilled beam in conjunction with chilled ceiling: Part 2 – Human response

    DEFF Research Database (Denmark)

    Arghand, Taha; Pastuszka, Zuzanna; Bolashikov, Zhecho Dimitrov

    2016-01-01

    The response of 24 subjects to the local environment established by localized chilled beam combined with chilled ceiling (LCBCC) was studied and compared with response to the environment generated by mixing ventilation combined with chilled ceiling (CCMV) at two temperature conditions of 26°C and...

  5. Individually controlled localized chilled beam in conjunction with chilled ceiling: Part 1 – Physical environment

    DEFF Research Database (Denmark)

    Arghand, Taha; Bolashikov, Zhecho Dimitrov; Kosonen, Risto

    2016-01-01

    This study investigates the indoor environment generated by localized chilled beam coupled with chilled ceiling (LCBCC) and compares it with the environment generated by mixing ventilation coupled with chilled ceiling (CCMV). The experiments were performed in a mock-up of single office (4.1 m × 4...

  6. Breaking through the glass ceiling: an industrial perspective.

    Science.gov (United States)

    Harlander, S K

    1996-11-01

    Many companies have recognized that the workforce of the future will be significantly more diverse than in the past. A substantial number of these new employees will be women. Industry must create an environment that attracts the best, brightest, and most talented women and provide an environment that empowers them to reach their full potential. Barriers to advancement, such as the real or perceived "glass ceiling," inhibit the individual and ultimately negatively affect the company. Successful companies will recognize that gender diversity is a critical business strategy and implement aggressive programs to assist women in breaking through the glass ceiling. Gender diversity initiatives should include examination of quality of life issues, training and development, organizational policies and practices, and management accountability. Mentoring programs clearly play an important role in gender diversity programs. Personal mentoring experiences in academic and corporate environments, as well as a pilot mentoring program at Land O'Lakes, will be discussed.

  7. Smashing into the Glass Ceiling for Women Managers.

    Science.gov (United States)

    Veale, Camilla; Gold, Jeff

    1998-01-01

    Interviews with 10 women administrators in a British metropolitan district council revealed the glass ceiling to be a complex phenomenon reaching beyond the employment sphere. Their career progression was hindered by lack of career counseling, family-work conflicts, lack of management development for women, and particularly a managerial culture…

  8. This School Is for Kids and Community.

    Science.gov (United States)

    American School Board Journal, 1982

    1982-01-01

    In Avon (Indiana), a community lacking public buildings, a middle school was built with community uses in mind. The swimming pool, gymnasium, and commons area can be blocked off for community use by using floor-to-ceiling gates. The school's heating, ventilating, and air conditioning systems are also energy-efficient. (Author/MLF)

  9. Graphite-modified cooling ceiling. A comparative evaluation of the performance; Graphitmodifizierte Kuehldecken. Eine vergleichende Bewertung zur Leistungsfaehigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, Gerd [Technische Univ. Muenchen (Germany); Fraunhofer-Institut fuer Bauphysik, Stuttgart (Germany); Hausladen, Gerhard [Technische Univ. Muenchen (Germany); Ingenieurbuero Hausladen GmbH, Muenchen (Germany); Jacobsen, Cornelia; Hutter, Christina; Hanusch, Christoph [Ingenieurbuero Hausladen GmbH, Muenchen (Germany); Schlitzberger, Stephan [Ingenieurbuero fuer Bauphysik Prof. Dr. Hauser GmbH, Kassel (Germany)

    2013-03-01

    In most cases, the utilization of graphite-modified building materials enhances their thermal conductivity. Thus, chilled ceiling systems achieve an enhanced thermal absorption in comparison to commercial chilled ceiling systems. For this, a simulation for the estimation of the thermal comfort as well as for the quantification of the impacts on the demand of electricity for the refrigeration is performed. The enhanced cooling capacity of the graphite-modified cooling ceiling 'Ecophit' affects the operation positively.

  10. Solidified package-storage device

    International Nuclear Information System (INIS)

    Takakura, Masahide

    1998-01-01

    Vitrification products such as high level radioactive liquid wastes are contained in a solidification package. A containing tube for vertically containing the solidification packages in multi-stages is disposed such that it passes through a ceiling slab. A shielding plug for preventing leakage of radiation from the solidification packages is fitted to an upper opening thereof. A lid of the containing tube is fitted above the plug. The lid is a carbon steel plate having a thickness of 10cm or more. A heat insulation layer comprising glass wool or rock wool is formed on the lower surface of the ceiling slab. A radiation shielding layer comprising such as an iron plate is formed on the lower surface of the heat insulation layer. Then, deterioration of the ceiling slug by heat can be prevented by the heat insulation layer even if high temperature cooling air flown from the upper opening of a ventilation tube should reach the lower surface of the ceiling slab. (I.N.)

  11. Impact of personalized ventilation combined with chilled ceiling on eye irritation symptoms

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Marcol, Bartosz; Kaczmarczyk, Jan

    2014-01-01

    Personalized ventilation (PV) improves inhaled air quality, because it provides fresh air to each workstation and directly to occupant’s breathing zone. The PV alone can be used for room ventilation when applied in conjunction with ceiling radiant cooling system, which removes sensible heat loads...... from the space. Combining PV with chilled ceiling may be an effective way to provide thermal comfort in rooms at air temperature higher than the recommended in the standards upper limit of 26°C (category II), because the operative temperature will be lower. However, combination of high air temperature...

  12. Assessment of Nitrogen Ceilings for Dutch Agricultural Soils to Avoid Adverse Environmental Impacts

    Directory of Open Access Journals (Sweden)

    Wim de Vries

    2001-01-01

    Full Text Available In the Netherlands, high traffic density and intensive animal husbandry have led to high emissions of reactive nitrogen (N into the environment. This leads to a series of environmental impacts, including: (1 nitrate (NO3 contamination of drinking water, (2 eutrophication of freshwater lakes, (3 acidification and biodiversity impacts on terrestrial ecosystems, (4 ozone and particle formation affecting human health, and (5 global climate change induced by emissions of N2O. Measures to control reactive N emissions were, up to now, directed towards those different environmental themes. Here we summarize the results of a study to analyse the agricultural N problem in the Netherlands in an integrated way, which means that all relevant aspects are taken into account simultaneously. A simple N balance model was developed, representing all crucial processes in the N chain, to calculate acceptable N inputs to the farm (so-called N ceiling and to the soil surface (application in the field by feed concentrates, organic manure, fertiliser, deposition, and N fixation. The N ceilings were calculated on the basis of critical limits for NO3 concentrations in groundwater, N concentrations in surface water, and ammonia (NH3 emission targets related to the protection of biodiversity of natural areas. Results show that in most parts of the Netherlands, except the western and the northern part, the N ceilings are limited by NH3 emissions, which are derived from critical N loads for nature areas, rather than limits for both ground- and surface water. On the national scale, the N ceiling ranges between 372 and 858 kton year–1 depending on the choice of critical limits. The current N import is 848 kton year–1. A decrease of nearly 60% is needed to reach the ceilings that are necessary to protect the environment against all adverse impacts of N pollution from agriculture.

  13. DETECTION OF BACTERIAL CYTOTOXIC ACTIVITIES FROM WATER-DAMAGED CEILING TILE MATERIAL FOLLOWING INCUBATION ON BLOOD AGAR

    Science.gov (United States)

    Samples of ceiling tiles with high levels of bacteria exhibited cytotoxic activities on a HEP-2 tissue culture assay. Ceiling tiles containing low levels of bacterial colonization did not show cytotoxic activities on the HEP-2 tissue culture assay. Using a spread plate procedure ...

  14. Do Female Researchers Face a Glass Ceiling in France? A Hazard Model of Promotions

    OpenAIRE

    Sabatier, Mareva

    2010-01-01

    Abstract The present article examines whether French female researchers face a glass ceiling, an invisible barrier to promotion. Using an original database from the National Institute for Agricultural Research, we estimate duration models for promotions. The methodology used allowed us to take into account censored observations and unobserved heterogeneity. Our results show a significant gender effect that does not contradict the glass-ceiling hypothesis. In addition, factors that ...

  15. Shattering the Glass Ceiling: Women in School Administration.

    Science.gov (United States)

    Patterson, Jean A.

    Consistent with national trends, white males hold the majority of public school administrator positions in North Carolina. This paper examines the barriers and underlying assumptions that have prevented women and minorities from gaining access to high-level positions in educational administration. These include: (1) the assumption that leadership…

  16. Glass Ceiling in the Workplace: An Analysis within the Stated-owned Enterprises and Multi-national Enterprises in China

    OpenAIRE

    Cao, Mengxi

    2015-01-01

    Currently, although the increasingly number of women has gained leadership positions, the glass ceiling phenomenon still exists in China, especially in multi-national enterprise. In brief, the road to the upper rungs for female is still challenging and difficult. Due to the nature of the enterprises, the performance of glass ceiling is different. The aim of this dissertation is to discuss different performance and influence of glass ceiling in the context of the multi-national enterprises (MN...

  17. Has the Copayment Ceiling Improved Financial Protection in the Korean National Health Insurance System? Evidence From the 2009 Policy Change.

    Science.gov (United States)

    Lee, Tae-Jin; Cheong, Chelim

    2017-11-01

    To relieve the financial burden faced by households, the Korean National Health Insurance (NHI) system introduced a "copayment ceiling," which evolved into a differential ceiling in 2009, with the copayment ceiling depending on patients' income. This study aimed to examine the effect of the differential copayment ceiling on financial protection and healthcare utilization, particularly focusing on whether its effects varied across different income groups. This study obtained data from the Korea Health Panel. The number of households included in the analysis was 6555 in 2008, 5859 in 2009, 5539 in 2010, and 5372 in 2011. To assess the effects of the differential copayment ceiling on utilization, out-of-pocket (OOP) payments, and catastrophic payments, various random-effects models were applied. Utilization was measured as treatment days, while catastrophic payments were defined as OOP payments exceeding 10% of household income. Among the right-hand side variables were the interaction terms of the new policy with income levels, as well as a set of household characteristics. The differential copayment ceiling contributed to increased utilization regardless of income levels both in all patients and in cancer patients. However, the new policy did not seem to reduce significantly the incidence of catastrophic payments among cancer patients, and even increased the incidence among all patients. The limited effect of the differential ceiling can be attributed to a high proportion of direct payments for services not covered by the NHI, as well as the relatively small number of households benefiting from the differential ceilings; these considerations warrant a better policy design.

  18. Heuristics as an alternative to variational calculus for optimization of a class of thermal insulation systems

    Energy Technology Data Exchange (ETDEWEB)

    Pramanick, A.K.; Das, P.K. [Indian Inst. of Technology, Kharagpur (India). Dept. of Mechanical Engineering

    2005-04-01

    This article reports an alternative treatment in lieu of the principle of variational calculus for a certain class of optimization problems. In particular, the optimum distribution of insulating material on one side of a flat plate for minimum heat transfer is sought when the other side is exposed to a laminar forced convection. Both conjugate and non-conjugate formulations of the problem are conceived and closed form solutions are presented. Interestingly, optimized insulation profile exhibits a category of equipartition principle in some macroscopic domain. Expression for minimum heat transfer is a function of Biot number in non-conjugate analysis of the model. Contrastingly, the non-dimensional group Jh{sub L} is the characteristic parameter for conjugate formulation. Finally, Bejan's method of intersecting asymptotes is employed to find an order of magnitude for a ceiling value of the wall material. With some scale factor, a range 0 < J{sub max} {<=} 1.506Pr {sup -} {sup 1/3} for the representative material volume can be ascertained, beyond which the optimization exercise reduces to a trivial one and traditional constant thickness profile becomes a recognized design. (author)

  19. New insulating particleboards from durian peel and coconut coir

    Energy Technology Data Exchange (ETDEWEB)

    Khedari, J.; Charoenvai, S.; Hirunlabh, J. [King Mongkut' s Univ. of Technology Thonburi, Bangkok (Thailand). Building Scientific Research Center

    2002-03-01

    The development of new particleboards from tropical fruit peels with low thermal conductivity as a component of construction panels for energy conservation of building is the main purpose of this study. Durian (Durio zibethinus) peels and coconut (Cocos nucifera) coir fibers were used as the raw material to manufacture particleboards. Two main parameters were investigated namely binder types, (UF 12%, PF 6% and IC 3%) and board density. In general, the effect of adhesive type on the properties of boards was not obvious whereas that of the density was more significant on most properties of boards. Experimental investigation indicated that the mechanical strength of all boards such as modulus of rupture and modulus of elasticity increased with increasing board density, but it is still rather low. However, this decreased the dimensional stability, measured in term of thickness swelling, and thermal conductivity as well. Finally, as the raw materials are agriculture waste, manufacturing particleboards is therefore an economic and interesting option. Such natural particleboards with a low thermal conductivity could be utilized for specific applications as in insulating ceiling and walls.(author)

  20. Studi Deskriptif Persepsi Karyawan Hotel Tentang Glass Ceiling Pada Wanita Dalam Pencapaian Jabatan Puncak Manajemen Hotel Di Kota Tanjung Selor

    OpenAIRE

    Merang, Merycona

    2015-01-01

    Penelitian ini dilakukan untuk mengetahui persepsi karyawan hotel tentang glass ceiling pada wanita dalam pencapaian jabatan puncak manajemen hotel di kota Tanjung Selor. Glass ceiling memiliki enam variable yaitu diri sendiri, tingkat pendidikan, lingkungan keluarga, kesehatan, lingkungan sosial, dan lingkungan kerja.Teknik analisa yang digunakan adalah kuantitatif deskriptif, crosstab dan chi square. Hasil penelitian menunjukkan bahwa secara keseluruhan, persepsi karyawan tentang glass ceil...

  1. Comparative Analysis Of Mid-Level Women Managers Perception Of The Existence Of Glass Ceiling In Singaporean And Malaysian Organizations

    OpenAIRE

    Vlado Dimovski; Miha Skerlavaj; Mandy Mok Kim Man

    2010-01-01

    This study presents an overview of glass-ceiling type barriers in organizations based on the perceptions of a sample of Singaporean and Malaysian mid-level women managers. Previous studies indicated the existence of a glass ceiling in organizations and presented strategic recommendations with regard to what corporations could do to remove or reduce the glass ceiling. This study investigates how women in middle management perceive their career advancement opportunities and what they consider t...

  2. The relationship between glass ceiling and power distance as a cultural variable by a new method

    Directory of Open Access Journals (Sweden)

    Naide Jahangirov

    2015-12-01

    Full Text Available Glass ceiling symbolizes a variety of barriers and obstacles that arise from gender inequality at business life. With this mind, culture influences gender dynamics. The purpose of this research was to examine the relationship between the glass ceiling and the power distance as a cultural variable within organizations. Gender variable is taken as a moderator variable in relationship between the concepts. In addition to conventional correlation analysis, we employed a new method to investigate this relationship in detail. The survey data were obtained from 109 people working at a research center which operated as a part of the non-profit private university in Ankara, Turkey. The relationship between the variables was revealed by a new method which was developed as an addition to the correlation in survey. The analysis revealed that the female staff perceived the glass ceiling and the power distance more intensely than the male staff. In addition, the medium level relation was determined between the power distance and the glass ceiling perception among female staff.

  3. Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2015-01-01

    The thermal environment and air quality conditions provided with combined system of chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for two occupants. The proposed system was compared with total volume HVAC solutions used today, namely mixing ventilation...... and chilled ceiling combined with mixing ventilation. The objective of the study was to evaluate whether PV can be the only ventilation system in the rooms equipped with chilled ceiling. The room air temperature was 26°C in cases with traditional systems and 28°C when PV was used. PV supplied air...... with the temperature of 25°C. PV improved thermal conditions and was up to nearly 10 times more efficient in delivering clean air at workstations than mixing ventilation systems, which resulted in strong protection of occupants from the cross-infection. In the room space outside workstations no substantial differences...

  4. Has the Copayment Ceiling Improved Financial Protection in the Korean National Health Insurance System? Evidence From the 2009 Policy Change

    Directory of Open Access Journals (Sweden)

    Tae-Jin Lee

    2017-11-01

    Full Text Available Objectives To relieve the financial burden faced by households, the Korean National Health Insurance (NHI system introduced a “copayment ceiling,” which evolved into a differential ceiling in 2009, with the copayment ceiling depending on patients’ income. This study aimed to examine the effect of the differential copayment ceiling on financial protection and healthcare utilization, particularly focusing on whether its effects varied across different income groups. Methods This study obtained data from the Korea Health Panel. The number of households included in the analysis was 6555 in 2008, 5859 in 2009, 5539 in 2010, and 5372 in 2011. To assess the effects of the differential copayment ceiling on utilization, out-of-pocket (OOP payments, and catastrophic payments, various random-effects models were applied. Utilization was measured as treatment days, while catastrophic payments were defined as OOP payments exceeding 10% of household income. Among the right-hand side variables were the interaction terms of the new policy with income levels, as well as a set of household characteristics. Results The differential copayment ceiling contributed to increased utilization regardless of income levels both in all patients and in cancer patients. However, the new policy did not seem to reduce significantly the incidence of catastrophic payments among cancer patients, and even increased the incidence among all patients. Conclusions The limited effect of the differential ceiling can be attributed to a high proportion of direct payments for services not covered by the NHI, as well as the relatively small number of households benefiting from the differential ceilings; these considerations warrant a better policy design.

  5. Experimental investigations of heat transfer in thermo active building systems in combination with suspended ceilings

    DEFF Research Database (Denmark)

    Alvarez, Maria Alonso; Hviid, Christian Anker; Weitzmann, Peter

    2014-01-01

    buildings to cover acoustic requirements hinders the use of TABS. To measure the reduction of the heat capacity, several experiments are performed in a room equipped with TABS in the upper deck and mixing ventilation. The heat transfer is measured for different suspended ceiling covering percentages...... that the ventilation rate has a high influence on the convective heat capacity. When the ventilation rate is increased from 1.7 h-1 to 2.9 h-1, the heat transfer coefficient increases up to 16% for the same occupancy and suspended ceiling layout.......Thermo Active Building Systems (TABS), described as radiant heating or cooling systems with pipes embedded in the building structure, represent a sustainable alternative to replace conventional systems by using source temperatures close to room temperatures. The use of suspended ceiling in office...

  6. StoThermSolar - possible applications and practical experience with transparent thermal insulation compound systems; StoThermSolar - Anwendungsmoeglichkeiten und praktische Erfahrungen mit transparenten Waermedaemmverbundsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Zwerger, M. [Sto AG, Stuehlingen (Germany)

    1996-11-01

    Sto AG has the motto `building conscientiously`. Consciousness of the environment acts as ethic for the firm. About 2000 employees develop, produce and market environmentally suitable product systems for facades, internal walls, ceilings and floors. They extend from paint and plaster, thermal insulation compound systems, concrete repair and acoustic systems to decorative profiles of old glass. (orig./HW) [Deutsch] `Bewusst Bauen` heisst das Leitwort der Sto AG. Umweltbewusstsein als Unternehmensethik. Rund 2000 Mitarbeiter entwickeln, produzieren und vermarkten umweltgerechte Produktsysteme fuer Fassade, Innenwand, Decke und Boden. Von Farben und Putzen, Waermedaemm-Verbundsystemen, Betoninstandsetzungs- oder Akustiksystemen bis zu Deco-Profilen aus Altglas. (orig./HW)

  7. A diagnosis of discrimination. Women physicians and the glass ceiling.

    Science.gov (United States)

    Sebastian, C

    1994-01-01

    Author Christy Sebastian writes about some of the limits facing women physicians, from the glass ceiling on down. She relates the limits faced by women physicians to the gender differences--both subtle and blatant--evident in society as a whole.

  8. WOMEN WORKFORCE LOOKING THROUGH THE GLASS CEILING

    OpenAIRE

    Sarıçiçek, Reyhan; Çopuroğlu, Filiz; Aytekin, Mehmet

    2017-01-01

    Women have begun to take part in business lifeintensively in the last century. However, despite the rapid rise in the numberof women in business world, the proportion of women among senior managers andleaders has been very low. Research on the subject demonstrates that women facedifficulties called ‘Glass Ceiling’, which cannot be seen apparently and at thesame time which is hard to overcome in order to reach the senior executivepositions. Glass ceiling refers to the difficulties that take pl...

  9. Leco. Thermo-active Ceilings & Free Cooling. Using free cooling in combination with thermo-active ceilings for integrated heating and cooling

    OpenAIRE

    Murphy, Mark Allen

    2010-01-01

    The largest potential for decreasing green house gas emissions, and therewith mitigating the effects of global climate change, comes from improving energy efficiency. Through the integration of heating and cooling systems into building elements, such as the thermo-active ceiling, improvements in energy efficiency can be achieved. Utilizing thermal mass to buffer temperature variations and to level out peak loads reduces the instantaneous power demands and enables traditional cooling e...

  10. Leco. Thermo-active Ceilings & Free Cooling. Using free cooling in combination with thermo-active ceilings for integrated heating and cooling

    OpenAIRE

    Murphy, Mark Allen

    2010-01-01

    - The largest potential for decreasing green house gas emissions, and therewith mitigating the effects of global climate change, comes from improving energy efficiency. Through the integration of heating and cooling systems into building elements, such as the thermo-active ceiling, improvements in energy efficiency can be achieved. Utilizing thermal mass to buffer temperature variations and to level out peak loads reduces the instantaneous power demands and enables traditional cool...

  11. 26 CFR 1.501(h)-3 - Lobbying or grass roots expenditures normally in excess of ceiling amount.

    Science.gov (United States)

    2010-04-01

    ... excess of ceiling amount. 1.501(h)-3 Section 1.501(h)-3 Internal Revenue INTERNAL REVENUE SERVICE... § 1.501(h)-3 Lobbying or grass roots expenditures normally in excess of ceiling amount. (a) Scope. This section provides rules under section 501(h) for determining whether an organization that has...

  12. EVALUATION OF FUNGAL GROWTH (PENICILLIUM GLABRUM) ON A CEILING TILE

    Science.gov (United States)

    The paper gives results of a study employing static chambers to study the impact of different equilibrium relative humidities (RHs) and moisture conditions on the ability of a new ceiling tile to support fungal growth. Amplification of the mold, Penicillium glabrum, occurred at R...

  13. Women in hospital medicine in the United Kingdom: glass ceiling, preference, prejudice or cohort effect?

    Science.gov (United States)

    McManus, I C; Sproston, K A

    2000-01-01

    To assess from official statistics whether there is evidence that the careers of women doctors in hospitals do not progress in the same way as those of men. The proportions of female hospital doctors overall (1963-96), and in the specialties of medicine, surgery, obstetrics and gynaecology, pathology, radiology/radiotherapy, anaesthetics and psychiatry (1974-1996) were examined. Additionally data were examined on career preferences and intentions from pre-registration house officers, final year medical students, and medical school applicants (1966-1991). Data were analysed according to cohort of entry to medical school to assess the extent of disproportionate promotion. The proportion of women in hospital career posts was largely explained by the rapidly increasing proportion of women entering medical school during the past three decades. In general there was little evidence for disproportionate promotion of women in hospital careers, although in surgery, hospital medicine and obstetrics and gynaecology, fewer women seemed to progress beyond the SHO grade, and in anaesthetics there were deficits of women at each career stage. Analyses of career preferences and intentions suggest that disproportionate promotion cannot readily be explained as differential choice by women. Although there is no evidence as such of a "glass ceiling" for women doctors in hospital careers, and the current paucity of women consultants primarily reflects historical trends in the numbers of women entering medical school, there is evidence in some cases of disproportionate promotion that is best interpreted as direct or indirect discrimination.

  14. Cellulose Insulation

    Science.gov (United States)

    1980-01-01

    Fire retardant cellulose insulation is produced by shredding old newspapers and treating them with a combination of chemicals. Insulating material is blown into walls and attics to form a fiber layer which blocks the flow of air. All-Weather Insulation's founders asked NASA/UK-TAP to help. They wanted to know what chemicals added to newspaper would produce an insulating material capable of meeting federal specifications. TAP researched the query and furnished extensive information. The information contributed to successful development of the product and helped launch a small business enterprise which is now growing rapidly.

  15. Breaking the Educational Glass Ceiling: An Interview with Harry Lenderman

    Science.gov (United States)

    Lenderman, Harry; Sandelands, Eric

    2005-01-01

    Purpose - To examine the role that corporations can and are playing in removing restrictions to a college or university education for their employees - the educational glass ceiling. Design/methodology/approach - An interview format is used with an experienced academic, and learning and development practitioner, drawing upon experiences and…

  16. [Impact of passing items above the ceiling on the assessment results of Peabody developmental motor scales].

    Science.gov (United States)

    Zhao, Gai; Bian, Yang; Li, Ming

    2013-12-18

    To analyze the impact of passing items above the roof level in the gross motor subtest of Peabody development motor scales (PDMS-2) on its assessment results. In the subtests of PDMS-2, 124 children from 1.2 to 71 months were administered. Except for the original scoring method, a new scoring method which includes passing items above the ceiling were developed. The standard scores and quotients of the two scoring methods were compared using the independent-samples t test. Only one child could pass the items above the ceiling in the stationary subtest, 19 children in the locomotion subtest, and 17 children in the visual-motor integration subtest. When the scores of these passing items were included in the raw scores, the total raw scores got the added points of 1-12, the standard scores added 0-1 points and the motor quotients added 0-3 points. The diagnostic classification was changed only in two children. There was no significant difference between those two methods about motor quotients or standard scores in the specific subtest (P>0.05). The passing items above a ceiling of PDMS-2 isn't a rare situation. It usually takes place in the locomotion subtest and visual-motor integration subtest. Including these passing items into the scoring system will not make significant difference in the standard scores of the subtests or the developmental motor quotients (DMQ), which supports the original setting of a ceiling established by upassing 3 items in a row. However, putting the passing items above the ceiling into the raw score will improve tracking of children's developmental trajectory and intervention effects.

  17. The relationship between glass ceiling and power distance as a cultural variable by a new method

    OpenAIRE

    Naide Jahangirov; Guler Saglam Ari; Seymur Jahangirov; Nuray Guneri Tosunoglu

    2015-01-01

    Glass ceiling symbolizes a variety of barriers and obstacles that arise from gender inequality at business life. With this mind, culture influences gender dynamics. The purpose of this research was to examine the relationship between the glass ceiling and the power distance as a cultural variable within organizations. Gender variable is taken as a moderator variable in relationship between the concepts. In addition to conventional correlation analysis, we employed a new method to investigate ...

  18. What Do We Know about Glass Ceiling Effects? A Taxonomy and Critical Review to Inform Higher Education Research

    Science.gov (United States)

    Jackson, Jerlando F. L.; O'Callaghan, Elizabeth M.

    2009-01-01

    The concept of "glass ceiling effects" has emerged in social science research in general and higher education in particular over the past 20 years. These studies have described the impediments that women and people of color encounter in their quest for senior-level positions (e.g., CEOs) in society as glass ceiling effects. Literature, both…

  19. Ceiling of care decisions at an older person's mental health unit in Gloucestershire.

    Science.gov (United States)

    Slack, Philip; Rose, Anneka

    2015-01-01

    This quality improvement project was inspired as an answer to a problem that many fellow psychiatric trainees had been struggling with while on-call covering the old age mental health hospital which includes a specialist dementia ward. The issue was that decisions around ceilings of care for patients were often not discussed or at least recorded in the electronic notes and as a result when reviewing deteriorating patients out of hours trainees would find themselves without any guidance on the treating medics opinion on what was in the best interests of the patient. This led to situations where unnecessary transfers to the acute hospital would occur overnight which could have been avoided with more consistent planning. Prior to initiating the changes it was recorded that nine out of 47 inpatients had documented decisions on ceiling of care of treatment in the consultant's ward round entries. Next policies from acute hospitals were reviewed, opinions were discussed in departmental meetings, and eventually there was agreed a change in procedure with the consultant on the dementia ward around resuscitation and ceiling of care status and consistent recording of this. Following the intervention there was seen an improvement in the recording of decisions around treatment and transfer of patients on the dementia ward of 80% (4/5) fully compliant with new criteria and then 71% (5/7) in successive cycles. Further communication both with relevant professionals on the old age ward and with the trainees on the on-call rota will be necessary to sustain any change but the centralised recording of resuscitation status and ceiling of care in the ward round entries have provided much more guidance than was previously available. In the future it may be possible to spread this policy throughout the entire old age mental health unit.

  20. Effects of Glass Ceiling on Women Career Development in Private Sector Organizations – Case of Sri Lanka

    Directory of Open Access Journals (Sweden)

    Bombuwela P. M.

    2013-06-01

    Full Text Available The study was entirely designed by centering the focal problem of the effect of Glass Ceiling on Women Career Development. The overall study was structure based on the conceptual framework built up using the information of literature survey. The study was conducted with the aim of obtaining the following objective. That is “To find out the Effect of Glass Ceiling on Women Career Development with regard to female executive level employees who are working in privatesector organizations.” At the same time, hypotheses are developed to find out whether there is a significant effect of Individual Factors, Family Factors, Organizational Factors and Cultural Factors on Women Career development. Merely this study has been completed with an empirical survey which was thoroughly conducted using a self-administered questionnaire and the sample consisted of 150 women executives. For presenting and analyzing the data both descriptive andinferential statistics were used. The findings reveal that the Glass Ceiling and Women Career Development have a moderate negative relationship, and also show that Individual Factors, OrganizationalFactors and Cultural Factors have a significant effect on Women Career Development whereas Family Factor has effects on the Glass Ceiling. Following the study results, a conclusion was eventually made that there are significant effects of the Glass Ceiling on WomenCareer Development of Executive level female employees working in private sector organizations in Sri Lanka. By taking all these facts into consideration, better recommendations have been made in this study. Finally, the most valuable suggestions for further studies and limitations of the study have been outlined.

  1. Thermal insulation

    International Nuclear Information System (INIS)

    Aspden, G.J.; Howard, R.S.

    1988-01-01

    The patent concerns high temperature thermal insulation of large vessels, such as the primary vessel of a liquid metal cooled nuclear reactor. The thermal insulation consists of multilayered thermal insulation modules, and each module comprises a number of metal sheet layers sandwiched between a back and front plate. The layers are linked together by straps and clips to control the thickness of the module. (U.K.)

  2. Managers' Beliefs about the Glass Ceiling: Interpersonal and Organizational Factors

    Science.gov (United States)

    Elacqua, Tina C.; Beehr, Terry A.; Hansen, Curtiss P.; Webster, Jennica

    2009-01-01

    The glass ceiling refers to the difficulty of women trying to be promoted into the top management levels. The present study examined managers' potential explanations, implicit or explicit, for why women rarely reach the top hierarchical levels in their own organization. Among 685 managers at a large Midwestern insurance company, a model was…

  3. Is there still a glass ceiling for women in academic surgery?

    Science.gov (United States)

    Zhuge, Ying; Kaufman, Joyce; Simeone, Diane M; Chen, Herbert; Velazquez, Omaida C

    2011-04-01

    Despite the dramatically increased entry of women into general surgery and surgical subspecialties, traditionally male-dominated fields, there remains a gross under-representation of women in the leadership positions of these departments. Women begin their careers with fewer academic resources and tend to progress through the ranks slower than men. Female surgeons also receive significantly lower salaries than their male counterparts and are more vulnerable to discrimination, both obvious and covert. Although some argue that female surgeons tend to choose their families over careers, studies have actually shown that women are as eager as men to assume leadership positions, are equally qualified for these positions as men, and are as good as men at leadership tasks.Three major constraints contribute to the glass-ceiling phenomenon: traditional gender roles, manifestations of sexism in the medical environment, and lack of effective mentors. Gender roles contribute to unconscious assumptions that have little to do with actual knowledge and abilities of an individuals and they negatively influence decision-making when it comes to promotions. Sexism has many forms, from subtle to explicit forms, and some studies show that far more women report being discriminately against than do men. There is a lack of same-sex mentors and role models for women in academic surgery, thereby isolating female academicians further. This review summarizes the manifestation of the glass-ceiling phenomenon, identifies some causes of these inequalities, and proposes different strategies for continuing the advancement of women in academic surgery and to shatter the glass ceiling.

  4. Women in hospital medicine in the United Kingdom: glass ceiling, preference, prejudice or cohort effect?

    Science.gov (United States)

    McManus, I; Sproston, K

    2000-01-01

    OBJECTIVE—To assess from official statistics whether there is evidence that the careers of women doctors in hospitals do not progress in the same way as those of men.
DESIGN—The proportions of female hospital doctors overall (1963-96), and in the specialties of medicine, surgery, obstetrics and gynaecology, pathology, radiology/radiotherapy, anaesthetics and psychiatry (1974-1996) were examined. Additionally data were examined on career preferences and intentions from pre-registration house officers, final year medical students, and medical school applicants (1966-1991).
ANALYSIS—Data were analysed according to cohort of entry to medical school to assess the extent of disproportionate promotion.
RESULTS—The proportion of women in hospital career posts was largely explained by the rapidly increasing proportion of women entering medical school during the past three decades. In general there was little evidence for disproportionate promotion of women in hospital careers, although in surgery, hospital medicine and obstetrics and gynaecology, fewer women seemed to progress beyond the SHO grade, and in anaesthetics there were deficits of women at each career stage. Analyses of career preferences and intentions suggest that disproportionate promotion cannot readily be explained as differential choice by women.
CONCLUSIONS—Although there is no evidence as such of a "glass ceiling" for women doctors in hospital careers, and the current paucity of women consultants primarily reflects historical trends in the numbers of women entering medical school, there is evidence in some cases of disproportionate promotion that is best interpreted as direct or indirect discrimination.

 PMID:10692956

  5. Circumventing the Glass Ceiling: Women Executives in American State Governments.

    Science.gov (United States)

    Bullard, Angela M.; Wright, Deil S.

    1993-01-01

    Data from 1984 (n=489) and 1988 (n=658) surveys show that female executives in state government have progressed in top positions in certain types of agencies, but much progress has occurred by avoiding, not breaking, the glass ceiling. Most notable male-female differences are in party affiliation, age, interagency mobility, career progress, and…

  6. 13 CFR 107.855 - Interest rate ceiling and limitations on fees charged to Small Businesses (“Cost of Money”).

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Interest rate ceiling and... § 107.855 Interest rate ceiling and limitations on fees charged to Small Businesses (“Cost of Money... weighted average interest rate you pay on your “qualified borrowings”. “Qualified borrowings” means your...

  7. Numerical investigation of upper-room UVGI disinfection efficacy in an environmental chamber with a ceiling fan.

    Science.gov (United States)

    Zhu, Shengwei; Srebric, Jelena; Rudnick, Stephen N; Vincent, Richard L; Nardell, Edward A

    2013-01-01

    This study investigated the disinfection efficacy of the upper-room ultraviolet germicidal irradiation (UR-UVGI) system with ceiling fans. The investigation used the steady-state computational fluid dynamics (CFD) simulations to solve the rotation of ceiling fan with a rotating reference frame. Two ambient air exchange rates, 2 and 6 air changes per hour (ACH), and four downward fan rotational speeds, 0, 80, 150 and 235 rpm were considered. In addition, the passive scalar concentration simulations incorporated ultraviolet (UV) dose by two methods: one based on the total exposure time and average UV fluence rate, and another based on SVE3* (New Scale for Ventilation Efficiency 3), originally defined to evaluate the mean age of the air from an air supply opening. Overall, the CFD results enabled the evaluation of UR-UVGI disinfection efficacy using different indices, including the fraction of remaining microorganisms, equivalent air exchange rate, UR-UVGI effectiveness and tuberculosis infection probability by the Wells-Riley equation. The results indicated that air exchange rate was the decisive factor for determining UR-UVGI performance in disinfecting indoor air. Using a ceiling fan could also improve the performance in general. Furthermore, the results clarified the mechanism for the ceiling fan to influence UR-UVGI disinfection efficacy. © 2013 The Authors Photochemistry and Photobiology © 2013 The American Society of Photobiology.

  8. Use of XPS thermal insulator boards in design of educational spaces

    African Journals Online (AJOL)

    Heating and cooling equipment capacity becomes smaller than half after proper implementation of thermal insulation. As air conditioning equipment becomes small, implementation of optimization not only becomes free but also reduces the overall cost of construction. Keywords: School, modern materials, Building and ...

  9. Estimation of thermal insulation performance in multi-layer insulator for liquid helium pipe

    International Nuclear Information System (INIS)

    Shibanuma, Kiyoshi; Kuriyama, Masaaki; Shibata, Takemasa

    1991-01-01

    For a multi-layer insulator around the liquid helium pipes for cryopumps of JT-60 NBI, a multi-layer insulator composed of 10 layers, which can be wound around the pipe at the same time and in which the respective layers are in concentric circles by shifting them in arrangement, has been developed and tested. As the result, it was shown that the newly developed multi-layer insulator has better thermal insulation performance than the existing one, i.e. the heat load of the newly developed insulator composed of 10 layers was reduced to 1/3 the heat load of the existing insulator, and the heat leak at the joint of the insulator in longitudinal direction of the pipe was negligible. In order to clarify thermal characteristics of the multi-layer insulator, the heat transfer through the insulator has been analyzed considering the radiation heat transfer by the netting spacer between the reflectors, and the temperature dependence on the emissivities and the heat transmission coefficients of these two components of the insulator. The analytical results were in good agreements with the experimental ones, so that the analytical method was shown to be valid. Concerning the influence of the number of layers and the layer density on the insulation performance of the insulator, analytical results showed that the multi-layer insulator with the number of layer about N = 20 and the layer density below 2.0 layer/mm was the most effective for the liquid helium pipe of a JT-60 cryopump. (author)

  10. Breakthrough: The Career Woman's Guide to Shattering the Glass Ceiling.

    Science.gov (United States)

    Flanders, Margaret L.

    This practical guide for all working women shows the reader how to recognize the barriers likely to confront her and to find the most effective way of breaking through. Chapter 1 summarizes causes of the glass ceiling and provides pointers on recognizing which situations are likely to cause problems. Chapter 2 helps the reader to understand her…

  11. Climatic and technological ceilings for Chinese rice stagnation based on yield gaps and yield trend pattern analysis.

    Science.gov (United States)

    Zhang, Tianyi; Yang, Xiaoguang; Wang, Hesong; Li, Yong; Ye, Qing

    2014-04-01

    Climatic or technological ceilings could cause yield stagnation. Thus, identifying the principal reasons for yield stagnation within the context of the local climate and socio-economic conditions are essential for informing regional agricultural policies. In this study, we identified the climatic and technological ceilings for seven rice-production regions in China based on yield gaps and on a yield trend pattern analysis for the period 1980-2010. The results indicate that 54.9% of the counties sampled experienced yield stagnation since the 1980. The potential yield ceilings in northern and eastern China decreased to a greater extent than in other regions due to the accompanying climate effects of increases in temperature and decreases in radiation. This may be associated with yield stagnation and halt occurring in approximately 49.8-57.0% of the sampled counties in these areas. South-western China exhibited a promising scope for yield improvement, showing the greatest yield gap (30.6%), whereas the yields were stagnant in 58.4% of the sampled counties. This finding suggests that efforts to overcome the technological ceiling must be given priority so that the available exploitable yield gap can be achieved. North-eastern China, however, represents a noteworthy exception. In the north-central area of this region, climate change has increased the yield potential ceiling, and this increase has been accompanied by the most rapid increase in actual yield: 1.02 ton ha(-1) per decade. Therefore, north-eastern China shows a great potential for rice production, which is favoured by the current climate conditions and available technology level. Additional environmentally friendly economic incentives might be considered in this region. © 2013 John Wiley & Sons Ltd.

  12. The Spanish gasoline market: From ceiling regulation to open market pricing

    International Nuclear Information System (INIS)

    Contin, I.; Correlje, A.; Huerta, E.

    1999-01-01

    This paper examines the evolution of the Spanish gasoline market from the abolition of the state oil monopoly (January 1993) to complete liberalization (October 1998). With the restructuring of the Spanish oil sector during the 1980s and early 1990s, a highly concentrated oligopoly emerged in the automotive fuels market. A system of price ceilings replaced the state administered prices in July 1990. Since then, new domestic and foreign operators have entered the market, particularly along the coast, near import terminals. Prices went up and then declined. These developments can be explained by an interplay of factors such as: the gradual decline in co-operation among the Spanish firms; the loss of market share of the largest of these, Repsol; the entry of independent operators and supermarkets; and the impact of the ceiling price system. By mid-1998 this system was abolished as the government considered it an impediment to further market liberalization. However, some crucial barriers to the entry of new suppliers remain

  13. Thermal insulating panel

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, J.T.

    1985-09-11

    A panel of thermal insulation material has at least one main portion which comprises a dry particulate insulation material compressed within a porous envelope so that it is rigid or substantially rigid and at least one auxiliary portion which is secured to and extends along at least one of the edges of the main portions. The auxiliary portions comprise a substantially uncompressed dry particulate insulation material contained within an envelope. The insulation material of the auxiliary portion may be the same as or may be different from the insulation material of the main portion. The envelope of the auxiliary portion may be made of a porous or a non-porous material. (author).

  14. Wall insulation system

    Energy Technology Data Exchange (ETDEWEB)

    Kostek, P.T.

    1987-08-11

    In a channel specially designed to fasten semi-rigid mineral fibre insulation to masonry walls, it is known to be constructed from 20 gauge galvanized steel or other suitable material. The channel is designed to have pre-punched holes along its length for fastening of the channel to the drywall screw. The unique feature of the channel is the teeth running along its length which are pressed into the surface of the butted together sections of the insulation providing a strong grip between the two adjacent pieces of insulation. Of prime importance to the success of this system is the recent technological advancements of the mineral fibre itself which allow the teeth of the channel to engage the insulation fully and hold without mechanical support, rather than be repelled or pushed back by the inherent nature of the insulation material. After the insulation is secured to the masonry wall by concrete nail fastening systems, the drywall is screwed to the channel.

  15. Collusion through Price Ceilings? In Search of a Focal-Point Effect

    NARCIS (Netherlands)

    Engelmann, D.; Müller, W.

    2008-01-01

    With this study we resume the search for a collusive focal-point effect of price ceilings in laboratory markets. We argue that market conditions in previous studies were unfavorable for collusion which may have been responsible for not finding such a focal-point effect. Our design aims at maximizing

  16. Collusion through price ceilings? In search of a focal-point effect

    NARCIS (Netherlands)

    Engelmann, D.; Müller, W.

    2011-01-01

    We resume the search for a collusive focal-point effect of price ceilings in laboratory markets. We argue that market conditions in previous studies were unfavorable for collusion which may have been responsible for not finding such a focal-point effect. Our design aims at maximizing the likelihood

  17. The status of women at one academic medical center. Breaking through the glass ceiling.

    Science.gov (United States)

    Nickerson, K G; Bennett, N M; Estes, D; Shea, S

    1990-10-10

    Despite recent gains in admission to medical school and in obtaining junior faculty positions, women remain underrepresented at senior academic ranks and in leadership positions in medicine. This discrepancy has been interpreted as evidence of a "glass ceiling" that prevents all but a few exceptional women from gaining access to leadership positions. We analyzed data from Columbia University College of Physicians & Surgeons, New York, NY, for all faculty hired from 1969 through 1988 and found that the likelihood of promotion on the tenure track was 0.40 for women and 0.48 for men (ratio, 0.82; 95% confidence interval, 0.56 to 1.20); on the clinical track the likelihood of promotion was 0.75 for women and 0.72 for men (ratio, 1.04; 95% confidence interval, 0.56 to 1.94). Additional analysis of current faculty showed that in the academic year 1988-1989 the proportion of women at each tenure track rank at the College of Physicians & Surgeons equaled or exceeded the national proportion of women graduating from medical school, once allowance was made for the average time lag necessary to attain each rank. On the clinical track women were somewhat overrepresented, particularly at the junior rank. National data that describe medical school faculty, which combine tenure and clinical tracks, showed that in 1988 women were proportionately represented at each rank once the lead time from graduation was considered. We conclude that objective evidence shows that women can succeed and are succeeding in gaining promotions in academic medicine.

  18. 46 CFR 116.422 - Ceilings, linings, trim, interior finish and decorations.

    Science.gov (United States)

    2010-10-01

    ... specified by the Commandant; or (2) Listed by Underwriters Laboratories, does not exceed 2 millimeters (.075...) or UL 723 by an independent laboratory. (c) Bulkheads, linings, and ceilings in high risk... reasonable number of coats of paint or with a marine finish meeting the requirements of § 164.012 in...

  19. Reduction of heat insulation upon soaking of the insulation layer

    Science.gov (United States)

    Achtliger, J.

    1983-09-01

    Improved thermal protection of hollow masonry by introduction of a core insulation between the inner and outer shell is discussed. The thermal conductivity of insulation materials was determined in dry state and after soaking by water with different volume-related moisture contents. The interpolated thermal conductivity values from three measured values at 10 C average temperature are presented as a function of the pertinent moisture content. Fills of expanded polystyrene, perlite and granulated mineral fibers, insulating boards made of mineral fibers and in situ cellular plastics produced from urea-formaldehyde resin were investigated. Test results show a confirmation of thermal conductivity values for insulating materials in hollow masonry.

  20. Storage facility for highly radioactive solid waste

    International Nuclear Information System (INIS)

    Kitano, Shozo

    1996-01-01

    A heat insulation plate is disposed at an intermediate portion between a ceiling wall of a storage chamber and an upper plate of a storage pit in parallel with them. A large number of highly radioactive solid wastes contained in canisters are contained in the storage pit. Cooling air is introduced from an air suction port, passes a channel on the upper side of the heat insulation plate formed by the ceiling of the storage chamber and the heat insulation plate, and flows from a flow channel on the side of the wall of the storage chamber to the lower portion of the storage pit. Afterheat is removed by the air flown from the lower portion to ventilation tubes at the outer side of container tubes. The air heated to a high temperature through the flow channel on the lower side of the heat insulation plate between the heat insulation plate and the upper plate of the storage pit, and is exhausted to an exhaustion port. Further, a portion of a heat insulation plate as a boundary between the cooling air and a high temperature air formed on the upper portion of the storage pit is formed as a heat transfer plate, so that the heat of the high temperature air is removed by the cooling air flowing the upper flow channel. This can prevent heating of the ceiling wall of the storage chamber. (I.N.)

  1. Effect of a ceiling fan ventilation system on finishing young bulls' health, behaviour and growth performance.

    Science.gov (United States)

    Magrin, L; Brscic, M; Lora, I; Rumor, C; Tondello, L; Cozzi, G; Gottardo, F

    2017-06-01

    This research aimed at assessing the effects of a ceiling fan ventilation system on health, feeding, social behaviour and growth response of finishing young bulls fattened indoors during a mild summer season. A total of 69 Charolais young bulls were housed in six pens without any mechanical ventilation system (Control) and in six pens equipped with ceiling fans. The experimental period lasted 98 days from June until mid-September 2014. Four experimental days were considered in order to assess the effect of the ventilation system under two different microclimatic conditions: 2 alert days at monthly interval with temperature humidity index (THI) between 75 and 78, and 2 normal days with THI⩽74. Health and behaviour of the bulls were evaluated through 8-h observation sessions starting after morning feed delivery. The study was carried out during a rather cool summer with a climate average THI of 68.9 and 4 days with average THI>75. Despite these mild climate conditions, ceiling fans lowered litter moisture and acted as a preventive measure for bulls' dirtiness (odd ratio=47.9; 95% CI 19.6 to 117.4). The risk of abnormal breathing was increased for Control bulls (odd ratio=40.7; 95% CI 5.4 to 304.2). When exposed to alert THI conditions, respiration rate and panting scores increased and rumination duration dropped in Control bulls compared with bulls provided with a ceiling fan. During observations under alert THI, bulls spent less time eating, more time being inactive and consumed more water compared with normal THI conditions. Bulls' daily dry matter intake measured during the observation sessions decreased on alert compared with normal THI days (Pbehaviour (rumination, lying down and drinking water) and respiration rate, however. The lack of a significant improvement of bulls' growth response should not discourage beef farmers from using ceiling fans in indoor systems, considering the likely increase in frequency and intensity of heat waves in the planet

  2. Effects of Glass Ceiling on Women Career Development in Private Sector Organizations – Case of Sri Lanka

    OpenAIRE

    Bombuwela P. M.; De Alwis A. Chamaru

    2013-01-01

    The study was entirely designed by centering the focal problem of the effect of Glass Ceiling on Women Career Development. The overall study was structure based on the conceptual framework built up using the information of literature survey. The study was conducted with the aim of obtaining the following objective. That is “To find out the Effect of Glass Ceiling on Women Career Development with regard to female executive level employees who are working in privatesector organizations.” At the...

  3. Preliminary research on the glass ceiling phenomenon in accounting and financial audit practice in Poland

    Directory of Open Access Journals (Sweden)

    Aleksandra Szewieczek

    2017-09-01

    Full Text Available Preliminary research on the glass ceiling phenomenon in accounting and financial audit practice in Poland The paper analyzes the glass ceiling phenomenon in the accounting practice in Poland. The essence and characteristics of this phenomenon are presented in relation to the accounting profession and statutory auditors. Research on the ‘glass ceiling’ carried out in various countries, with a particular reference to the profession of a statutory auditor, was reviewed. The paper presents results of the research on the phenomenon conducted among a selected sample of audit firms in Poland. The results of the study confirmed the occurrence of this phenomenon in Poland with greater intensity in larger entities. The large scale of the glass ceiling phenomenon in the professional life of women in accounting is reflected by a high percentage of women in the profession of statutory auditor contrasted by the very low participation in senior managerial positions, e.g. partners in auditing companies. The paper uses the method of critical analysis of the literature and empirical data. Moreover, qualitative analysis was used for the data reported by audit firms

  4. Propagation Characteristics of Multilayer Hybrid Insulator-Metal-Insulator and Metal-Insulator-Metal Plasmonic Waveguides

    Directory of Open Access Journals (Sweden)

    M. Talafi Noghani

    2014-02-01

    Full Text Available Propagation characteristics of symmetrical and asymmetrical multilayer hybrid insulator-metal-insulator (HIMI and metal-insulator-metal (HMIM plasmonic slab waveguides are investigated using the transfer matrix method. Propagation length (Lp and spatial length (Ls are used as two figures of merit to qualitate the plasmonic waveguides. Symmetrical structures are shown to be more performant (having higher Lp and lower Ls, nevertheless it is shown that usage of asymmetrical geometry could compensate for the performance degradation in practically realized HIMI waveguides with different substrate materials. It is found that HMIM slab waveguide could support almost long-range subdiffraction plasmonic modes at dimensions lower than the spatial length of the HIMI slab waveguide.

  5. Glass ceiling effects: the case of taiwanese top executives

    OpenAIRE

    Tzu-i Wang; Jennjou Chen

    2010-01-01

    Gender discrimination in labor markets has been an important issue in labor economics. The main purpose of this paper is to empirically study glass ceiling effects, and investigate whether female workers are indeed being discriminated against, particularly during the promotion process, in top management positions in Taiwan. This paper uses data from 4,485 large firms in Taiwan to study whether there are gender preferences when the chairperson of a company chooses a chief executive officer (CE...

  6. Effect of façade systems on the performance of cooling ceilings: In situ measurements

    Directory of Open Access Journals (Sweden)

    Katharina Eder

    2015-03-01

    Full Text Available This article presents an innovative façade system designed to increase the thermal comfort inside an office room and to enhance the cooling capacity of the suspended cooling ceiling. A series of measurements is conducted in an existing office building with different façade systems (i.e., a combination of glazing and shading. An innovative façade system is developed based on this intensive set of measurements. The new system enhances the thermal comfort and cooling capacity of the suspended cooling ceiling. The main usage of the new system is the refurbishment and improvement of existing façade systems.

  7. Does drywall installers' innovative idea reduce the ergonomic exposures of ceiling installation: A field case study.

    Science.gov (United States)

    Dasgupta, Priyadarshini Sengupta; Punnett, Laura; Moir, Susan; Kuhn, Sarah; Buchholz, Bryan

    2016-07-01

    The study was conducted to assess an intervention suggested by the workers to reduce the physical or ergonomic exposures of the drywall installation task. The drywall installers were asked to brainstorm on innovative ideas that could reduce their ergonomic exposures during the drywall installation work. The workers proposed the idea of using a 'deadman' (narrow panel piece) to hold the panels to the ceiling while installing them. The researcher collected quantitative exposure data (PATH, 3DSSPP) at the baseline and intervention phases and compared the phases to find out any change in the exposure while using the 'deadman'. Results showed that ergonomic exposures (such as overhead arm and awkward trunk postures and heavy load handling) were reduced at the intervention phase while using the 'deadman' with an electrically operated lift. The concept of the 'deadman', which was shown to help reduce musculoskeletal exposures during ceiling installation, can be used to fabricate a permanent ergonomic tool to support the ceiling drywall panel. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. Passive Collecting of Solar Radiation Energy using Transparent Thermal Insulators, Energetic Efficiency of Transparent Thermal Insulators

    Directory of Open Access Journals (Sweden)

    Smajo Sulejmanovic

    2014-11-01

    Full Text Available This paper explains passive collection of solar radiation energy using transparent thermal insulators. Transparent thermal insulators are transparent for sunlight, at the same time those are very good thermal insulators. Transparent thermal insulators can be placed instead of standard conventional thermal insulators and additionally transparent insulators can capture solar radiation, transform it into heat and save heat just as standard insulators. Using transparent insulators would lead to reduce in usage of fossil fuels and would help protection of an environment and reduce effects of global warming, etc.

  9. Above the glass ceiling? A comparison of matched samples of female and male executives.

    Science.gov (United States)

    Lyness, K S; Thompson, D E

    1997-06-01

    In this study the authors compare career and work experiences of executive women and men. Female (n = 51) and male (n = 56) financial services executives in comparable jobs were studied through archival information on organizational outcomes and career histories, and survey measures of work experiences. Similarities were found in several organizational outcomes, such as compensation, and many work attitudes. Important differences were found, however, with women having less authority, receiving fewer stock options, and having less international mobility than men. Women at the highest executive levels reported more obstacles than lower level women. The gender differences coupled with women's lower satisfaction with future career opportunities raise questions about whether women are truly above the glass ceiling or have come up against a 2nd, higher ceiling.

  10. Expatriate Glass Ceiling : The Perception of Malaysian Female Employees

    OpenAIRE

    Ghosh, Chandrika

    2013-01-01

    Evidence from research has repeatedly pointed to the small number of women managers sent on expatriation. The percentage of female expatriates during the 1990’s was as low as 14% of all expatriate managers (Windham/NFTC, 1997). Researchers found that, similar to the glass ceiling that prevents women from reaching top management levels, there seems to be another glass barrier that stops them from taking up international assignments. This subtle, invisible barrier has been referred to as the ex...

  11. Self-Healing Wire Insulation

    Science.gov (United States)

    Parrish, Clyde F. (Inventor)

    2012-01-01

    A self-healing system for an insulation material initiates a self-repair process by rupturing a plurality of microcapsules disposed on the insulation material. When the plurality of microcapsules are ruptured, reactants within the plurality of microcapsules react to form a replacement polymer in a break of the insulation material. This self-healing system has the ability to repair multiple breaks in a length of insulation material without exhausting the repair properties of the material.

  12. Is a Widening Gender Wage Gap Necessarily Caused by a Glass Ceiling?

    NARCIS (Netherlands)

    I.P. van Staveren (Irene)

    2012-01-01

    textabstractContrary to what is generally assumed, the gender wage gap and the glass ceiling may not necessarily be positively related. An exploratory analysis of aggregate public service personnel data for Uganda shows that the gender wage gap is small at the middle level of management, whereas it

  13. 76 FR 21579 - Energy Conservation Program: Test Procedures for Walk-In Coolers and Walk-In Freezers

    Science.gov (United States)

    2011-04-15

    ...-in: the wall and ceiling panels (hereafter referred to as non-floor panels); floor panels; the... requirements for wall, ceiling, door, and floor insulation panels used in walk-ins. See 42 U.S.C. 6313(f... entirely or partially comprised of glass, a transparent material, or both and is used for display purposes...

  14. 26 CFR 1.103(n)-7T - Election to allocate State ceiling to certain facilities for local furnishing of electricity...

    Science.gov (United States)

    2010-04-01

    ... facilities for local furnishing of electricity (temporary). 1.103(n)-7T Section 1.103(n)-7T Internal Revenue... (CONTINUED) Items Specifically Excluded from Gross Income § 1.103(n)-7T Election to allocate State ceiling to... amount that would have been New York's State ceiling (as defined in section 103(n)(4) and A-1 of § 1.103...

  15. Women and work : an exploratory study on problems and perspectives relating to the apparent inability of women teachers to break through the glass ceiling

    OpenAIRE

    2012-01-01

    M.B.A. The aim of this research is to determine whether a glass ceiling does exist in education, and if so, possible reasons why women teachers fail to break through the so-called "glass ceiling". Objectives The objectives identified include the following: To determine historical perspectives on women and work To explore the incidence of glass ceilings To ascertain the value the Department of Education places on women teachers To determine by means of questionnaires whether there is a 'gla...

  16. Complete Model-Based Equivalence Class Testing for the ETCS Ceiling Speed Monitor

    DEFF Research Database (Denmark)

    Braunstein, Cécile; Haxthausen, Anne Elisabeth; Huang, Wen-ling

    2014-01-01

    In this paper we present a new test model written in SysML and an associated blackbox test suite for the Ceiling Speed Monitor (CSM) of the European Train Control System (ETCS). The model is publicly available and intended to serve as a novel benchmark for investigating new testing theories...

  17. 78 FR 62494 - Energy Conservation Program: Energy Conservation Standards for Ceiling Fans

    Science.gov (United States)

    2013-10-22

    ... consumers' decisions about purchasing air conditioning equipment. For example: How much more or less likely are consumers to own or purchase an air conditioner if they already have a ceiling fan? How much more... and to facilitate this process, DOE has identified several related issues in this RFI on which DOE...

  18. Comments by ABCT's first female president on overcoming the glass ceiling.

    Science.gov (United States)

    Nelson-Gray, Rosemery O

    2012-12-01

    At the annual convention of the Association for Behavioral and Cognitive Therapies in New York City in November 2009, a most interesting panel discussion occurred: Overcoming the Glass Ceiling: A Conversation With the Trailblazers. This article is a written version of my oral presentation at this panel discussion in my role as ABCT's first female president. Copyright © 2012. Published by Elsevier Ltd.

  19. Heat insulation support device

    International Nuclear Information System (INIS)

    Takahashi, Hiroyuki; Koda, Tomokazu; Motojima, Osamu; Yamamoto, Junya.

    1994-01-01

    The device of the present invention comprises a plurality of heat insulation legs disposed in a circumferential direction. Each of the heat insulative support legs has a hollow shape, and comprises an outer column and an inner column as support structures having a heat insulative property (heat insulative structure), and a thermal anchor which absorbs compulsory displacement by a thin flat plate (displacement absorber). The outer column, the thermal anchor and the inner column are connected by a support so as to offset the positional change of objects to be supported due to shrinkage when they are shrunk. In addition, the portion between the superconductive coils as the objects to be supported and the inner column is connected by the support. The superconductive thermonuclear device is entirely contained in a heat insulative vacuum vessel, and the heat insulative support legs are disposed on a lower lid of the heat insulative vacuum vessel. With such a constitution, they are strengthened against lateral load and buckling, thereby enabling to reduce the amount of heat intrusion while keeping the compulsory displacement easy to be absorbed. (I.N.)

  20. Between Meditation and Propaganda. Explicit and Implicit Religious Imagery in Baroque Ceiling Painting

    Czech Academy of Sciences Publication Activity Database

    Mádl, Martin

    2011-01-01

    Roč. 16, 1/2 (2011), s. 11-28 ISSN 1408-0419 R&D Projects: GA ČR GA408/08/0745 Institutional research plan: CEZ:AV0Z80330511 Keywords : baroque * ceiling painting * iconography * church Subject RIV: AL - Art, Architecture, Cultural Heritage

  1. Economically optimal thermal insulation

    Energy Technology Data Exchange (ETDEWEB)

    Berber, J.

    1978-10-01

    Exemplary calculations to show that exact adherence to the demands of the thermal insulation ordinance does not lead to an optimal solution with regard to economics. This is independent of the mode of financing. Optimal thermal insulation exceeds the values given in the thermal insulation ordinance.

  2. Panels of microporous insulation

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, J.A.; Morgan, D.E.; Jackson, J.D.J.

    1990-08-07

    Microporous thermal insulation materials have a lattice structure in which the average interstitial dimension is less than the mean free path of the molecules of air or other gas in which the material is arranged. This results in a heat flow which is less than that attributable to the molecular heat diffusion of the gas. According to this invention, a method is provided for manufacturing panels of microporous thermal insulation, in particular such panels in which the insulation material is bonded to a substrate. The method comprises the steps of applying a film of polyvinyl acetate emulsion to a non-porous substrate, and compacting powdery microporous thermal insulation material against the film so as to cause the consolidated insulation material to bond to the substrate and form a panel. The polyvinyl acetate may be applied by brushing or spraying, and is preferably allowed to dry prior to compacting the insulation material. 1 fig.

  3. Total dose hardening of buried insulator in implanted silicon-on-insulator structures

    International Nuclear Information System (INIS)

    Mao, B.Y.; Chen, C.E.; Pollack, G.; Hughes, H.L.; Davis, G.E.

    1987-01-01

    Total dose characteristics of the buried insulator in implanted silicon-on-insulator (SOI) substrates have been studied using MOS transistors. The threshold voltage shift of the parasitic back channel transistor, which is controlled by charge trapping in the buried insulator, is reduced by lowering the oxygen dose as well as by an additional nitrogen implant, without degrading the front channel transistor characteristics. The improvements in the radiation characteristics of the buried insulator are attributed to the decrease in the buried oxide thickness or to the presence of the interfacial oxynitride layer formed by the oxygen and nitrogen implants

  4. Rent sharing as a driver of the glass ceiling effect

    OpenAIRE

    Matano, Alessia; Naticchioni, Paolo

    2012-01-01

    In this paper we show that rent sharing plays a role in accounting for the glass ceiling effect. We make use of a unique employer-employee panel database for Italy from 1996 to 2003, which allows controlling for observed individual and firm heterogeneity and for collective bargaining. Moreover, by means of IV quantile fixed effects estimates we can cope with unobserved heterogeneity and endogeneity. We then go on to discuss the possible related explanations.

  5. Influence of a Cooled Ceiling on Indoor Air Quality in a Displacement Ventilated Room Examined by Means of Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Brohus, Henrik

    The influence of a cooled ceiling on the air quality in a displacement ventilated room is examined by means of CFD. The objective of the study is to examine how the flow field in a displacement ventilated room is influenced when a cooled ceiling removes a major part of the total heat I9ad, and in...

  6. Survey of thermal insulation systems

    International Nuclear Information System (INIS)

    Kinoshita, Izumi

    1983-01-01

    Better thermal insulations have been developed to meet the growing demands of industry, and studies on thermal insulation at both high temperature and low temperature have been widely performed. The purpose of this survey is to summarize data on the performances and characteristics of thermal insulation materials and thermal insulation structures (for instance, gas cooled reactors, space vehicles and LNG storage tanks), and to discuss ravious problems regarding the design of thermal insulation structures of pool-type LMFBRs. (author)

  7. Detection of UV Pulse from Insulators and Application in Estimating the Conditions of Insulators

    Science.gov (United States)

    Wang, Jingang; Chong, Junlong; Yang, Jie

    2014-10-01

    Solar radiation in the band of 240-280 nm is absorbed by the ozone layer in the atmosphere, and corona discharges from high-voltage apparatus emit in air mainly in the 230-405 nm range of ultraviolet (UV), so the band of 240-280 nm is called UV Solar Blind Band. When the insulators in a string deteriorate or are contaminated, the voltage distribution along the string will change, which causes the electric fields in the vicinity of insulators change and corona discharge intensifies. An UV pulse detection method to check the conditions of insulators is presented based on detecting the UV pulse among the corona discharge, then it can be confirmed that whether there exist faulty insulators and whether the surface contamination of insulators is severe for the safe operation of power systems. An UV-I Insulator Detector has been developed, and both laboratory tests and field tests have been carried out which demonstrates the practical viability of UV-I Insulator Detector for online monitoring.

  8. Thermal insulation

    International Nuclear Information System (INIS)

    Pinsky, G.P.

    1977-01-01

    Thermal insulation for vessels and piping within the reactor containment area of nuclear power plants is disclosed. The thermal insulation of this invention can be readily removed and replaced from the vessels and piping for inservice inspection, can withstand repeated wettings and dryings, and can resist high temperatures for long periods of time. 4 claims, 3 figures

  9. Wrapped Multilayer Insulation

    Science.gov (United States)

    Dye, Scott A.

    2015-01-01

    New NASA vehicles, such as Earth Departure Stage (EDS), Orion, landers, and orbiting fuel depots, need improved cryogenic propellant transfer and storage for long-duration missions. Current cryogen feed line multilayer insulation (MLI) performance is 10 times worse per area than tank MLI insulation. During each launch, cryogenic piping loses approximately 150,000 gallons (equivalent to $300,000) in boil-off during transfer, chill down, and ground hold. Quest Product Development Corp., teaming with Ball Aerospace, developed an innovative advanced insulation system, Wrapped MLI (wMLI), to provide improved thermal insulation for cryogenic feed lines. wMLI is high-performance multilayer insulation designed for cryogenic piping. It uses Quest's innovative discrete-spacer technology to control layer spacing/ density and reduce heat leak. The Phase I project successfully designed, built, and tested a wMLI prototype with a measured heat leak 3.6X lower than spiral-wrapped conventional MLI widely used for piping insulation. A wMLI prototype had a heat leak of 7.3 W/m2, or 27 percent of the heat leak of conventional MLI (26.7 W/m2). The Phase II project is further developing wMLI technology with custom, molded polymer spacers and advancing the product toward commercialization via a rigorous testing program, including developing advanced vacuuminsulated pipe for ground support equipment.

  10. Cement bonded wood wool boards from podocarpus spp. for low ...

    African Journals Online (AJOL)

    ... sound insulation in walls, ceilings and floors, roofs, sound barriers and thermal insulation. Further research is required to investigate the use of different wood species and different mineral binders. Keywords: podocarpus spp, wood-wool, wood-cement composites. Journal of Civil Engineering Research and Practice Vol.

  11. Combined effect of upstream surge chamber and sloping ceiling tailrace tunnel on dynamic performance of turbine regulating system of hydroelectric power plant

    International Nuclear Information System (INIS)

    Guo, Wencheng; Yang, Jiandong

    2017-01-01

    Highlights: • Nonlinear mathematical model and Hopf bifurcation analysis of turbine regulating system are presented. • Dynamic performance of turbine regulating system under 0.5 times Thoma sectional area is analyzed and a novel dynamic performance is revealed. • Relationship between two bifurcation lines and wave superposition is studied. • Combined effect mechanisms of upstream surge chamber and sloping ceiling tailrace tunnel on stability are revealed and optimization methods are proposed. - Abstract: Based on the nonlinear mathematical model of the turbine regulating system of hydroelectric power plant with upstream surge chamber and sloping ceiling tailrace tunnel and the Hopf bifurcation theory, this paper firstly studies the dynamic performance of the turbine regulating system under 0.5 times Thoma sectional area of surge chamber, and reveals a novel dynamic performance. Then, the relationship between the two bifurcation lines and the wave superposition of upstream surge chamber and sloping ceiling tailrace tunnel is analyzed. Finally, the effect mechanisms of the wave superposition on the system stability are investigated, and the methods to improve the system stability are proposed. The results indicate that: Under the combined effect of upstream surge chamber and sloping ceiling tailrace tunnel, the dynamic performance of the turbine regulating system of hydroelectric power plant shows an obvious difference on the two sides of the critical sectional area of surge chamber. There are two bifurcation lines for the condition of 0.5 times Thoma sectional area, i.e. Bifurcation line 1 and Bifurcation line 2, which represent the stability characteristics of the flow oscillation of “penstock-sloping ceiling tailrace tunnel” and the water-level fluctuation in upstream surge chamber, respectively. The stable domain of the system is determined by Bifurcation line 2. The effect of upstream surge chamber mainly depends on its sectional area, while the

  12. Numerical investigation of diffuse ceiling ventilation in an office under different operating conditions

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Petersen, Steffen

    2014-01-01

    is a numerical study of the performance of a six person office equipped with diffuse ventilation ceiling. In total six extreme, yet realistic, operation scenarios were simulated to study the performance including different occupancy, ventilation rates and supply air temperatures. The performance was studied...

  13. From the glass door to the glass ceiling: An analysis of the gender wage gap by age groups

    OpenAIRE

    Elena Dalla Chiara; Eleonora Matteazzi; Ilaria Petrarca

    2014-01-01

    Using 2009 EU-SILC data for France, Italy, the Netherlands and the United Kingdom, we decompose the gender wage gap for prime age workers. We adopt an age group approach to identify when and how the glass door and the glass ceiling effects arise and their persistency over time. The empirical results verify that the raw gender wage gap increases with age. In all considered countries, the glass ceiling effect is completely realized by the age of 30 and increases over time. French, Italian and B...

  14. Magnetically self-insulated transformers

    International Nuclear Information System (INIS)

    Novac, B.M.; Smith, I.R.; Brown, J.

    2002-01-01

    Magnetic insulation is the only practicable form of insulation for much equipment used in ultrahigh pulsed-power work, including transmission lines and plasma opening switches. It has not however so far been successfully exploited in the transformers that are necessarily involved, and the first proposed design that appeared more than 30 years ago raised apparently insuperable problems. The two novel arrangements for a magnetically insulated transformer described in this paper overcome the problems faced by the earlier designs and also offer considerable scope for development in a number of important areas. Theoretical justification is given for their insulating properties, and this is confirmed by proof-of-principle results obtained from a small-scale experimental prototype in which magnetic insulation was demonstrated at up to 100 kV. (author)

  15. Women's health and women's leadership in academic medicine: hitting the same glass ceiling?

    Science.gov (United States)

    Carnes, Molly; Morrissey, Claudia; Geller, Stacie E

    2008-11-01

    The term "glass ceiling" refers to women's lack of advancement into leadership positions despite no visible barriers. The term has been applied to academic medicine for over a decade but has not previously been applied to the advancement of women's health. This paper discusses (1) the historical linking of the advances in women's health with women's leadership in academic medicine, (2) the slow progress of women into leadership in academic medicine, and (3) indicators that the advancement of women's health has stalled. We make the case that deeply embedded unconscious gender-based biases and assumptions underpin the stalled advancement of women on both fronts. We conclude with recommendations to promote progress beyond the apparent glass ceiling that is preventing further advancement of women's health and women leaders. We emphasize the need to move beyond "fixing the women" to a systemic, institutional approach that acknowledges and addresses the impact of unconscious, gender-linked biases that devalue and marginalize women and issues associated with women, such as their health.

  16. Research on vacuum insulation for cryocables

    International Nuclear Information System (INIS)

    Graneau, P.

    1974-01-01

    Vacuum insulation, as compared with solid insulation, simplifies the construction of both resistive or superconducting cryogenic cables. The common vacuum space in the cable can furnish thermal insulation between the environment and the cryogenic coolant, provide electrical insulation between conductors, and establish thermal isolation between go- and return-coolant streams. The differences between solid and vacuum high voltage insulation are discussed, and research on the design, materials selection, and testing of vacuum insulated cryogenic cables is described

  17. Sound Insulation between Dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2011-01-01

    Regulatory sound insulation requirements for dwellings exist in more than 30 countries in Europe. In some countries, requirements have existed since the 1950s. Findings from comparative studies show that sound insulation descriptors and requirements represent a high degree of diversity...... and initiate – where needed – improvement of sound insulation of new and existing dwellings in Europe to the benefit of the inhabitants and the society. A European COST Action TU0901 "Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions", has been established and runs...... 2009-2013. The main objectives of TU0901 are to prepare proposals for harmonized sound insulation descriptors and for a European sound classification scheme with a number of quality classes for dwellings. Findings from the studies provide input for the discussions in COST TU0901. Data collected from 24...

  18. Objective and subjective evaluation of the acoustic comfort in classrooms.

    Science.gov (United States)

    Zannin, Paulo Henrique Trombetta; Marcon, Carolina Reich

    2007-09-01

    The acoustic comfort of classrooms in a Brazilian public school has been evaluated through interviews with 62 teachers and 464 pupils, measurements of background noise, reverberation time, and sound insulation. Acoustic measurements have revealed the poor acoustic quality of the classrooms. Results have shown that teachers and pupils consider the noise generated and the voice of the teacher in neighboring classrooms as the main sources of annoyance inside the classroom. Acoustic simulations resulted in the suggestion of placement of perforated plywood on the ceiling, for reduction in reverberation time and increase in the acoustic comfort of the classrooms.

  19. The inaccuracy of heat transfer characteristics for non-insulated and insulated spherical containers neglecting the influence of heat radiation

    International Nuclear Information System (INIS)

    Wong, King-Leung; Salazar, Jose Luis Leon; Prasad, Leo; Chen, Wen-Lih

    2011-01-01

    In this investigation, the differences of heat transfer characteristics for insulated and non-insulated spherical containers between considering and neglecting the influence of heat radiation are studied by the simulations in some practical situations. It is found that the heat radiation effect cannot be ignored in conditions of low ambient convection heat coefficients (such ambient air) and high surface emissivities, especially for the non-insulated and thin insulated cases. In most practical situations when ambient temperature is different from surroundings temperature and the emissivity of insulation surface is different from that of metal wall surface, neglecting heat radiation will result in inaccurate insulation effect and heat transfer errors even with very thick insulation. However, the insulation effect considering heat radiation will only increase a very small amount after some dimensionless insulated thickness (such insulation thickness/radius ≥0.2 in this study), thus such dimensionless insulated thickness can be used as the optimum thickness in practical applications. Meanwhile, wrapping a material with low surface emissivity (such as aluminum foil) around the oxidized metal wall or insulation layer (always with high surface emissivity) can achieve very good insulated effect for the non-insulated or thin insulated containers.

  20. Electrical insulating liquid: A review

    Directory of Open Access Journals (Sweden)

    Deba Kumar Mahanta

    2017-08-01

    Full Text Available Insulating liquid plays an important role for the life span of the transformer. Petroleum-based mineral oil has become dominant insulating liquid of transformer for more than a century for its excellent dielectric and cooling properties. However, the usage of petroleum-based mineral oil, derived from a nonrenewable energy source, has affected the environment for its nonbiodegradability property. Therefore, researchers direct their attention to renewable and biodegradable alternatives. Palm fatty acid ester, coconut oil, sunflower oil, etc. are considered as alternatives to replace mineral oil as transformer insulation liquid. This paper gives an extensive review of different liquid insulating materials used in a transformer. Characterization of different liquids as an insulating material has been discussed. An attempt has been made to classify different insulating liquids-based on different properties.

  1. Biodegradation performance of environmentally-friendly insulating oil

    Science.gov (United States)

    Yang, Jun; He, Yan; Cai, Shengwei; Chen, Cheng; Wen, Gang; Wang, Feipeng; Fan, Fan; Wan, Chunxiang; Wu, Liya; Liu, Ruitong

    2018-02-01

    In this paper, biodegradation performance of rapeseed insulating oil (RDB) and FR3 insulating oil (FR3) was studied by means of ready biodegradation method which was performed with Organization for Economic Co-operation and Development (OECD) 301B. For comparison, the biodegradation behaviour of 25# mineral insulating oil was also characterized with the same method. The testing results shown that the biodegradation degree of rapeseed insulating oil, FR3 insulating oil and 25# mineral insulating oil was 95.8%, 98.9% and 38.4% respectively. Following the “new chemical risk assessment guidelines” (HJ/T 154 - 2004), which illustrates the methods used to identify and assess the process safety hazards inherent. The guidelines can draw that the two vegetable insulating oils, i.e. rapeseed insulating oil and FR3 insulating oil are easily biodegradable. Therefore, the both can be classified as environmentally-friendly insulating oil. As expected, 25# mineral insulating oil is hardly biodegradable. The main reason is that 25# mineral insulating oil consists of isoalkanes, cyclanes and a few arenes, which has few unsaturated bonds. Biodegradation of rapeseed insulating oil and FR3 insulating oil also remain some difference. Biodegradation mechanism of vegetable insulating oil was revealed from the perspective of hydrolysis kinetics.

  2. Voltage-driven magnetization control in topological insulator/magnetic insulator heterostructures

    Directory of Open Access Journals (Sweden)

    Michael E. Flatté

    2017-05-01

    Full Text Available A major barrier to the development of spin-based electronics is the transition from current-driven spin torque, or magnetic-field-driven magnetization reversal, to a more scalable voltage-driven magnetization reversal. To achieve this, multiferroic materials appear attractive, however the effects in current materials occur at very large voltages or at low temperatures. Here the potential of a new class of hybrid multiferroic materials is described, consisting of a topological insulator adjacent to a magnetic insulator, for which an applied electric field reorients the magnetization. As these materials lack conducting states at the chemical potential in their bulk, no dissipative charge currents flow in the bulk. Surface states at the interface, if present, produce effects similar to surface recombination currents in bipolar devices, but can be passivated using magnetic doping. Even without conducting states at the chemical potential, for a topological insulator there is a finite spin Hall conductivity provided by filled bands below the chemical potential. Spin accumulation at the interface with the magnetic insulator provides a torque on the magnetization. Properly timed voltage pulses can thus reorient the magnetic moment with only the flow of charge current required in the leads to establish the voltage. If the topological insulator is sufficiently thick the resulting low capacitance requires little charge current.

  3. Gas insulated substations

    CERN Document Server

    2014-01-01

    This book provides an overview on the particular development steps of gas insulated high-voltage switchgear, and is based on the information given with the editor's tutorial. The theory is kept low only as much as it is needed to understand gas insulated technology, with the main focus of the book being on delivering practical application knowledge. It discusses some introductory and advanced aspects in the meaning of applications. The start of the book presents the theory of Gas Insulated Technology, and outlines reliability, design, safety, grounding and bonding, and factors for choosing GIS. The third chapter presents the technology, covering the following in detail: manufacturing, specification, instrument transformers, Gas Insulated Bus, and the assembly process. Next, the book goes into control and monitoring, which covers local control cabinet, bay controller, control schemes, and digital communication. Testing is explained in the middle of the book before installation and energization. Importantly, ...

  4. Beyond the Glass Ceiling : The Glass Cliff and Its Lessons for Organizational Policy

    NARCIS (Netherlands)

    Bruckmueller, Susanne; Ryan, Michelle K.; Rink, Floor; Haslam, S. Alexander

    It has been almost 30 years since the metaphor of the glass ceiling was coined to describe the often subtle, but very real, barriers that women face as they try to climb the organizational hierarchy. Here we review evidence for a relatively new form of gender discriminationcaptured by the metaphor

  5. Insulation structure of thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Takayuki; Usami, Saburo; Tsukamoto, Hideo; Kikuchi, Mitsuru

    1998-01-01

    The present invention provides an insulating structure of a thermonuclear device, in which insulation materials between toroidal coils are not broken even if superconductive toroidal coils are used. Namely, a tokamak type thermonuclear device of an insulating structure type comprises superconductive toroidal coils for confining plasmas arranged in a circular shape directing the center each at a predetermined angle, and the toroidal coils are insulated from each other. The insulation materials are formed by using a biaxially oriented fiber reinforced plastics. The contact surface of the toroidal coils and the insulating materials are arranged so that they are contact at a woven surface of the fiber reinforced plastics. Either or both of the contact surfaces of the fiber reinforced plastics and the toroidal coils are coated with a high molecular compound having a low friction coefficient. With such a constitution, since the interlayer shearing strength of the biaxially oriented fiber reinforced plastics is about 1/10 of the compression strength, the shearing stress exerted on the insulation material is reduced. Since a static friction coefficient on the contact surface is reduced to provide a structure causing slipping, shearing stress does not exceeds a predetermined limit. As a result, breakage of the insulation materials between the toroidal coils can be prevented. (I.S.)

  6. Daytime space cooling with phase change material ceiling panels discharged using rooftop photovoltaic/thermal panels and night-time ventilation

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Pean, Thibault Quentin; Gennari, Luca

    2016-01-01

    The possibility of using photovoltaic/thermal panels for producing cold water through the process of night-time radiative cooling was experimentally examined. The cold water was used to discharge phase change material in ceiling panels in a climatic chamber. Both night-time radiative cooling...... the photovoltaic/thermal varied from 56% to 122%. The phase change material ceiling panels were thus, capable of providing an acceptable thermal environment and the photovoltaic/thermal panels were able to provide most of the required electricity and cold water needed for cooling....

  7. Hydro turbine governor’s power control of hydroelectric unit with sloping ceiling tailrace tunnel

    Science.gov (United States)

    Fu, Liang; Wu, Changli; Tang, Weiping

    2018-02-01

    The primary frequency regulation and load regulation transient process when the hydro turbine governor is under the power mode of hydropower unit with sloping ceiling tailrace are analysed by field test and numerical simulation in this paper. A simulation method based on “three-zone model” to simulate small fluctuation transient process of the sloping ceiling tailrace is proposed. The simulation model of hydraulic turbine governor power mode is established by governor’s PLC program identification and parameter measurement, and the simulation model is verified by the test. The slow-fast-slow “three-stage regulation” method which can improve the dynamic quality of hydro turbine governor power mode is proposed. The power regulation strategy and parameters are optimized by numerical simulation, the performance of primary frequency regulation and load regulation transient process when the hydro turbine governor is under power mode are improved significantly.

  8. Thermal insulation

    International Nuclear Information System (INIS)

    Durston, J.G.; Birch, W.; Facer, R.I.; Stuart, R.A.

    1977-01-01

    Reference is made to liquid metal cooled nuclear reactors. In the arrangement described the reactor vessel is clad with thermal insulation comprising a layer of insulating blocks spaced from the wall and from each other; each block is rigidly secured to the wall, and the interspaces are substantially closed against convectional flow of liquid by resilient closure members. A membrane covering is provided for the layer of blocks, with venting means to allow liquid from the reactor vessel to penetrate between the covering and the layer of blocks. The membrane covering may comprise a stainless steel sheet ribbed in orthogonal pattern to give flexibility for the accommodation of thermal strain. The insulating blocks may be comprised of stainless steel or cellular or porous material and may be hollow shells containing ceramic material or gas fillings. (U.K.)

  9. Insulation Reformulation Development

    Science.gov (United States)

    Chapman, Cynthia; Bray, Mark

    2015-01-01

    The current Space Launch System (SLS) internal solid rocket motor insulation, polybenzimidazole acrylonitrile butadiene rubber (PBI-NBR), is a new insulation that replaced asbestos-based insulations found in Space Shuttle heritage solid rocket boosters. PBI-NBR has some outstanding characteristics such as an excellent thermal erosion resistance, low thermal conductivity, and low density. PBI-NBR also has some significant challenges associated with its use: Air entrainment/entrapment during manufacture and lay-up/cure and low mechanical properties such as tensile strength, modulus, and fracture toughness. This technology development attempted to overcome these challenges by testing various reformulated versions of booster insulation. The results suggest the SLS program should continue to investigate material alternatives for potential block upgrades or use an entirely new, more advanced booster. The experimental design was composed of a logic path that performs iterative formulation and testing in order to maximize the effort. A lab mixing baseline was developed and documented for the Rubber Laboratory in Bldg. 4602/Room 1178.

  10. Radon mitigation experience in difficult-to-mitigate schools

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.

    1990-01-01

    Initial radon mitigation experience in schools has shown sub-slab depressurization (SSD) to be generally effective in reducing elevated levels of radon in schools that have a continuous layer of clean, coarse aggregate underneath the slab. However, mitigation experience is limited in schools without sub-slab aggregate and in schools with characteristics such as return-air ductwork underneath the slab or unducted return-air plenums in the drop ceiling that are open to the sub-slab area (via open tops of block walls). Mitigation of schools with utility tunnels and of schools constructed over crawl spaces is also limited. Three Maryland schools exhibiting some of the above characteristics are being researched to help understand the mechanisms that control radon entry and mitigation in schools where standard SSD systems are not effective. This paper discusses specific characteristics of potentially difficult-to-mitigate schools and, where applicable, details examples from the three Maryland schools

  11. Modeling Outcomes with Floor or Ceiling Effects: An Introduction to the Tobit Model

    Science.gov (United States)

    McBee, Matthew

    2010-01-01

    In gifted education research, it is common for outcome variables to exhibit strong floor or ceiling effects due to insufficient range of measurement of many instruments when used with gifted populations. Common statistical methods (e.g., analysis of variance, linear regression) produce biased estimates when such effects are present. In practice,…

  12. You Can't Get There from Here: Working Women and the Glass Ceiling.

    Science.gov (United States)

    Business and Professional Women's Foundation, Washington, DC.

    Over the past two decades women and minorities have made unprecedented strides into the work force, yet discrimination due to gender and race is still a problem. The dearth of women in management is due to the "glass ceiling" phenomenon--the organizational, attitudinal, and societal barriers that effectively keep women and minorities…

  13. Proposal for the award of an industrial support contract for paintwork, false ceilings, plasterwork and false floors at CERN

    CERN Document Server

    2006-01-01

    This document concerns the award of a contract for paintwork, false ceilings, plasterwork and false floors at CERN. The Finance Committee is invited to agree to the negotiation of a contract with the firm PREZIOSO (FR), the lowest bidder, for the provision of paintwork, false ceilings, plasterwork and false floors at CERN for a period of three years for a total amount not exceeding 538 419 euros (830 381 Swiss francs), not subject to revision for the first two years. The contract will include options for two one-year extensions beyond the initial threeyear period.

  14. Glass Ceiling Converted Into Glass Transparency: A Study On The Factors Making Women Executives Successful In The Indian Banking Sector

    OpenAIRE

    Sachdeva, Dr Geeta

    2014-01-01

    Economic reforms in the Indian economy along with gradual opening up of a conservative society to a modern society preceded breaking the glass ceiling or conversion Glass ceiling into a Glass Transparency in the Indian Banking Sector. This is backed by a recent study of 240 top Indian companies by EMA Partners, the global executive-search firm, which says more than a half of India's women chief executives are accounted for by the banking and financial services industry. This paper studie...

  15. Sound insulation and reverberation time for classrooms - Criteria in regulations and classification schemes in the Nordic countries

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2016-01-01

    Acoustic regulations or guidelines for schools exist in all five Nordic countries. The acoustic criteria depend on room uses and deal with airborne and impact sound insulation, reverberation time, sound absorption, traffic noise, service equipment noise and other acoustic performance...... have become more extensive and stricter during the last two decades. The paper focuses on comparison of sound insulation and reverberation time criteria for classrooms in regulations and classification schemes in the Nordic countries. Limit values and changes over time will be discussed as well as how...... not identical. The national criteria for quality level C correspond to the national regulations or recommendations for new-build. The quality levels A and B are intended to define better acoustic performance than C, and D lower performance. Typically, acoustic regulations and classification criteria for schools...

  16. Perceptions of Women in Management: A Thematic Analysis of Razing the Glass Ceiling

    Science.gov (United States)

    Baumgartner, Mindy S.; Schneider, David E.

    2010-01-01

    Despite advances that women have made in organizations over the past century, women continue to be underrepresented in upper management positions. Based on a review of literature, six issues that women face when encountering the glass ceiling were examined. The goal of the current study involved having women who have succeeded at breaking the…

  17. 42 CFR 413.40 - Ceiling on the rate of increase in hospital inpatient costs.

    Science.gov (United States)

    2010-10-01

    ... October 1, 2002, is the percentage increase projected by the hospital market basket index. (4) Target... target amount for the previous cost reporting period, updated by the market basket percentage increase... each cost reporting period, the ceiling is determined by multiplying the updated target amount, as...

  18. Cooper Pairs in Insulators?

    International Nuclear Information System (INIS)

    Valles, James

    2008-01-01

    Nearly 50 years elapsed between the discovery of superconductivity and the emergence of the microscopic theory describing this zero resistance state. The explanation required a novel phase of matter in which conduction electrons joined in weakly bound pairs and condensed with other pairs into a single quantum state. Surprisingly, this Cooper pair formation has also been invoked to account for recently uncovered high-resistance or insulating phases of matter. To address this possibility, we have used nanotechnology to create an insulating system that we can probe directly for Cooper pairs. I will present the evidence that Cooper pairs exist and dominate the electrical transport in these insulators and I will discuss how these findings provide new insight into superconductor to insulator quantum phase transitions.

  19. Environmental safety providing during heat insulation works and using thermal insulation materials

    Directory of Open Access Journals (Sweden)

    Velichko Evgeny

    2017-01-01

    Full Text Available This article considers the negative effect of thermal insulating materials and products on human health and environment pollution, particularly in terms of the composition of environmentally hazardous construction products. The authors have analyzed the complex measures for providing ecological safety, sanitary and epidemiological requirements, rules and regulations both during thermal insulation works and throughout the following operation of buildings and premises. The article suggests the protective and preventive measures to reduce and eliminate the negative impact of the proceeding of thermal insulation works on the natural environment and on human health.

  20. Breaking through the uncertainty ceiling in LA-ICP-MS U-Pb geochronology

    Science.gov (United States)

    Horstwood, M.

    2016-12-01

    Sources of systematic uncertainty associated with session-to-session bias are the dominant contributor to the 2% (2s) uncertainty ceiling that currently limits the accuracy of LA-ICP-MS U-Pb geochronology. Sources include differential downhole fractionation (LIEF), `matrix effects' and ablation volume differences, which result in irreproducibility of the same reference material across sessions. Current mitigation methods include correcting for LIEF mathematically, using matrix-matched reference materials, annealing material to reduce or eliminate radiation damage effects and tuning for robust plasma conditions. Reducing the depth and volume of ablation can also mitigate these problems and should contribute to the reduction of the uncertainty ceiling. Reducing analysed volume leads to increased detection efficiency, reduced matrix-effects, eliminates LIEF, obviates ablation rate differences and reduces the likelihood of intercepting complex growth zones with depth, thereby apparently improving material homogeneity. High detection efficiencies (% level) and low sampling volumes (20um box, 1-2um deep) can now be achieved using MC-ICP-MS such that low volume ablations should be considered part of the toolbox of methods targeted at improving the reproducibility of LA-ICP-MS U-Pb geochronology. In combination with other strategies these improvements should be feasible on any ICP platform. However, reducing the volume of analysis reduces detected counts and requires a change of analytical approach in order to mitigate this. Appropriate strategies may include the use of high efficiency cell and torch technologies and the optimisation of acquisition protocols and data handling techniques such as condensing signal peaks, using log ratios and total signal integration. The tools required to break the 2% (2s) uncertainty ceiling in LA-ICP-MS U-Pb geochronology are likely now known but require a coherent strategy and change of approach to combine their implementation and realise

  1. 16 CFR 460.18 - Insulation ads.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES LABELING AND ADVERTISING OF HOME INSULATION § 460.18 Insulation ads. (a) If your ad gives an R-value, you must give the type of insulation and... your ad gives a price, you must give the type of insulation, the R-value at a specific thickness, the...

  2. Nonlinear modeling and stability analysis of hydro-turbine governing system with sloping ceiling tailrace tunnel under load disturbance

    International Nuclear Information System (INIS)

    Guo, Wencheng; Yang, Jiandong; Wang, Mingjiang; Lai, Xu

    2015-01-01

    Highlights: • Novel nonlinear mathematical model of hydro-turbine governing system is proposed. • Hopf bifurcation analysis on the governing system is conducted. • Stability of the system under load disturbance is studied. • Influence of four factors on stability is analyzed. • Optimization methods of improving system stability are put forward. - Abstract: In order to overcome the problem of nonlinear dynamics of hydro-turbine governing system with sloping ceiling tailrace tunnel, which is caused by the interface movement of the free surface-pressurized flow in the tailrace tunnel, and the difficulty of analyzing the stability of system, this paper uses the Hopf bifurcation theory to study the stability of hydro-turbine governing system of hydropower station with sloping ceiling tailrace tunnel. Firstly, a novel and rational nonlinear mathematical model of the hydro-turbine governing system is proposed. This model contains the dynamic equation of pipeline system which can accurately describe the motion characteristics of the interface of free surface-pressurized flow in sloping ceiling tailrace tunnel. According to the nonlinear mathematical model, the existence and direction of Hopf bifurcation of the nonlinear dynamic system are analyzed. Furthermore, the algebraic criterion of the occurrence of Hopf bifurcation is derived. Then the stability domain and bifurcation diagram of hydro-turbine governing system are drawn by the algebraic criterion, and the characteristics of stability under different state parameters are investigated. Finally, the influence of step load value, ceiling slope angle and section form of tailrace tunnel and water depth at the interface in tailrace tunnel on stability are analyzed based on stable domain. The results indicate that: The Hopf bifurcation of hydro-turbine governing system with sloping ceiling tailrace tunnel is supercritical. The phase space trajectories of characteristic variables stabilize at the equilibrium points

  3. Electrical insulators for the theta-pinch fusion reactor

    International Nuclear Information System (INIS)

    Clinard, F.W. Jr.

    1976-01-01

    The five major applications for electrical insulators in the Reference Theta Pinch Reactor are as follows: (1) first-wall insulator, (2) blanket intersegment insulator, (3) graphite encapsulating insulator, (4) implosion coil insulator, and (5) compression coil insulator. Insulator design proposals and some preliminary test results are given for each application

  4. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  5. Semiconductor of spinons: from Ising band insulator to orthogonal band insulator.

    Science.gov (United States)

    Farajollahpour, T; Jafari, S A

    2018-01-10

    We use the ionic Hubbard model to study the effects of strong correlations on a two-dimensional semiconductor. The spectral gap in the limit where on-site interactions are zero is set by the staggered ionic potential, while in the strong interaction limit it is set by the Hubbard U. Combining mean field solutions of the slave spin and slave rotor methods, we propose two interesting gapped phases in between: (i) the insulating phase before the Mott phase can be viewed as gapping a non-Fermi liquid state of spinons by the staggered ionic potential. The quasi-particles of underlying spinons are orthogonal to physical electrons, giving rise to the 'ARPES-dark' state where the ARPES gap will be larger than the optical and thermal gap. (ii) The Ising insulator corresponding to ordered phase of the Ising variable is characterized by single-particle excitations whose dispersion is controlled by Ising-like temperature and field dependences. The temperature can be conveniently employed to drive a phase transition between these two insulating phases where Ising exponents become measurable by ARPES and cyclotron resonance. The rare earth monochalcogenide semiconductors where the magneto-resistance is anomalously large can be a candidate system for the Ising band insulator. We argue that the Ising and orthogonal insulating phases require strong enough ionic potential to survive the downward renormalization of the ionic potential caused by Hubbard U.

  6. Semiconductor of spinons: from Ising band insulator to orthogonal band insulator

    Science.gov (United States)

    Farajollahpour, T.; Jafari, S. A.

    2018-01-01

    We use the ionic Hubbard model to study the effects of strong correlations on a two-dimensional semiconductor. The spectral gap in the limit where on-site interactions are zero is set by the staggered ionic potential, while in the strong interaction limit it is set by the Hubbard U. Combining mean field solutions of the slave spin and slave rotor methods, we propose two interesting gapped phases in between: (i) the insulating phase before the Mott phase can be viewed as gapping a non-Fermi liquid state of spinons by the staggered ionic potential. The quasi-particles of underlying spinons are orthogonal to physical electrons, giving rise to the ‘ARPES-dark’ state where the ARPES gap will be larger than the optical and thermal gap. (ii) The Ising insulator corresponding to ordered phase of the Ising variable is characterized by single-particle excitations whose dispersion is controlled by Ising-like temperature and field dependences. The temperature can be conveniently employed to drive a phase transition between these two insulating phases where Ising exponents become measurable by ARPES and cyclotron resonance. The rare earth monochalcogenide semiconductors where the magneto-resistance is anomalously large can be a candidate system for the Ising band insulator. We argue that the Ising and orthogonal insulating phases require strong enough ionic potential to survive the downward renormalization of the ionic potential caused by Hubbard U.

  7. Microbial Volatile Organic Compound Emissions from Stachybotrys chartarum growing on Gypsum Wallboard and Ceiling tile

    Science.gov (United States)

    This study compared seven toxigenic strains of S. chartarum found in water-damaged buildings to characterize the microbial volatile organic compound (MVOC) emissions profile while growing on gypsum wallboard (W) and ceiling tile (C) coupons. The inoculated coupons with their sub...

  8. Working beyond the Glass Ceiling: Women Managers in Initial Teacher Training in England

    Science.gov (United States)

    Thompson, Barbara

    2007-01-01

    Recently in England, women have been successful in obtaining managerial responsibilities in the field of teacher training. In this setting at least, it could be argued that the glass ceiling that has kept women in lower-paid and lower status posts has been shattered. In order to explore this proposition from the perspective of those who work as…

  9. Career Barriers for Women Executives and the Glass Ceiling Syndrome: The Case Study Comparison between French and Turkish Women Executives

    OpenAIRE

    Akpinar-Sposito, Cansu

    2013-01-01

    International audience; The situation where gender pay gaps are typically wider at the top of the wage distribution is known as the 'glass ceiling'. It is one of the most compelling metaphors recently used for analyzing inequality between men and women in the workplace, in order to describe a barrier to further advancement once women have attained a certain level. The general-case glass ceiling hypothesis states that not only is it more difficult for women than for men to be promoted up level...

  10. Metal-insulator-semiconductor photodetectors.

    Science.gov (United States)

    Lin, Chu-Hsuan; Liu, Chee Wee

    2010-01-01

    The major radiation of the sun can be roughly divided into three regions: ultraviolet, visible, and infrared light. Detection in these three regions is important to human beings. The metal-insulator-semiconductor photodetector, with a simpler process than the pn-junction photodetector and a lower dark current than the MSM photodetector, has been developed for light detection in these three regions. Ideal UV photodetectors with high UV-to-visible rejection ratio could be demonstrated with III-V metal-insulator-semiconductor UV photodetectors. The visible-light detection and near-infrared optical communications have been implemented with Si and Ge metal-insulator-semiconductor photodetectors. For mid- and long-wavelength infrared detection, metal-insulator-semiconductor SiGe/Si quantum dot infrared photodetectors have been developed, and the detection spectrum covers atmospheric transmission windows.

  11. Metal-Insulator-Semiconductor Photodetectors

    Directory of Open Access Journals (Sweden)

    Chu-Hsuan Lin

    2010-09-01

    Full Text Available The major radiation of the Sun can be roughly divided into three regions: ultraviolet, visible, and infrared light. Detection in these three regions is important to human beings. The metal-insulator-semiconductor photodetector, with a simpler process than the pn-junction photodetector and a lower dark current than the MSM photodetector, has been developed for light detection in these three regions. Ideal UV photodetectors with high UV-to-visible rejection ratio could be demonstrated with III-V metal-insulator-semiconductor UV photodetectors. The visible-light detection and near-infrared optical communications have been implemented with Si and Ge metal-insulator-semiconductor photodetectors. For mid- and long-wavelength infrared detection, metal-insulator-semiconductor SiGe/Si quantum dot infrared photodetectors have been developed, and the detection spectrum covers atmospheric transmission windows.

  12. Thou shalt not pass?: Examining the existence of an immigrant glass ceiling in Sweden, 1970-1990

    Directory of Open Access Journals (Sweden)

    Jonas Helgertz

    2011-01-01

    Full Text Available The paper studies a sample of natives and 18 immigrant nationalities in the Swedish labor market between 1970 and 1990. The purpose is examining the existence of an immigrant specific glass ceiling. Results suggest a considerable overall advantage in terms of the probability of experiencing upward occupational mobility for native Swedish males. Despite this, the pattern does not correspond to the theoretical expectations of a glass ceiling. Using the ISEI classification of occupational status, the advantage experienced by Swedish males is consistent in the private manufacturing and private service sectors, compared to the experience of immigrants and women. The public sector generally suggests a similar pattern according to linguistic background. In this sector, certain groups of women are, however, observed to experience an advantage from low occupational status origins.

  13. Effects of insulation on potted superconducting coils

    International Nuclear Information System (INIS)

    Zeller, A.F.; DeKamp, J.C.; Magsig, C.T.; Nolen, J.A.; McInturff, A.D.

    1989-01-01

    Test coils using identical wire but with either Formvar or Polyesterimid insulation were fabricated to determine the effects of insulation on training behavior. It was found that the type of insulation did not affect the training behavior. While considerable attention has been paid to epoxy formulations used for superconducting coils, little study has been devoted to the effects of the wire insulation on training behavior. If the insulation does not bind well with the epoxy, the wires will not be held securely in place, and training will be required to make the coil operate at its design limit. In fact, the coil may never reach its design current, showing considerable degredation. Conversely, if the epoxy-insulation reaction is to soften or weaken the insulation, then shorts and/or training may result. The authors have undertaken a study of the effects of the insulation on potted coils wet wound with Stycast 2850 FT epoxy. The wire was insulated with one of two insulting varnishes: Formvar (a polyvinyl formal resin) or Polyesterimid (a phenolic resin). Formvar is the standard insulation in the United States while Polyesterimid the European standard

  14. Vacuum foil insulation system

    International Nuclear Information System (INIS)

    Hanson, J.P.; Sabolcik, R.E.; Svedberg, R.C.

    1976-01-01

    In a multifoil thermal insulation package having a plurality of concentric cylindrical cups, means are provided for reducing heat loss from the penetration region which extends through the cups. At least one cup includes an integral skirt extending from one end of the cup to intersection with the penetration means. Assembly of the insulation package with the skirted cup is facilitated by splitting the cup to allow it to be opened up and fitted around the other cups during assembly. The insulation is for an implantable nuclear powered artificial heart

  15. Topological insulators

    CERN Document Server

    Franz, Marcel

    2013-01-01

    Topological Insulators, volume six in the Contemporary Concepts of Condensed Matter Series, describes the recent revolution in condensed matter physics that occurred in our understanding of crystalline solids. The book chronicles the work done worldwide that led to these discoveries and provides the reader with a comprehensive overview of the field. Starting in 2004, theorists began to explore the effect of topology on the physics of band insulators, a field previously considered well understood. However, the inclusion of topology brings key new elements into this old field. Whereas it was

  16. PD-pulse characteristics in rotating machine insulation

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens; Jensen, A

    1994-01-01

    In this paper results are presented from investigations on partial discharges (PD) in insulation systems, resembling the stator insulation in high voltage rotating machines. A model, simulating a stator winding in a slot, has been developed, consisting of simple rotating machine insulation test...... bars with epoxy/mica insulation, mounted between steel sheets forming a dot, in order to investigate the fundamental behaviour of PD in insulation defects in epoxy/mica insulation and the characteristics of the resulting electrical pulses. Stator slot couplers (SSC) were used to detect pulses coming...

  17. Giuseppe Bragalli and Bolognese ceiling painting in the Czech Lands in the 17th century

    Czech Academy of Sciences Publication Activity Database

    Mádl, Martin

    2011-01-01

    Roč. 59, č. 5 (2011), s. 350-379 ISSN 0049-5123 R&D Projects: GA ČR GA408/08/0745 Institutional research plan: CEZ:AV0Z80330511 Keywords : baroque art * painting * ceiling painting * architecture Subject RIV: AL - Art, Architecture, Cultural Heritage

  18. Experimental Study of an Integrated System with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per

    . And the thermal comfort is analyzed by draught rate vertical temperature gradient and radiant temperature asymmetry. Finally the effect of plenum and diffuse ceiling is discussed. This report mainly focuses on the experiment results and discussions. Therefore, some details about the measurement are not presented...

  19. Women in boards: Dichotomising the glass ceiling

    Directory of Open Access Journals (Sweden)

    Krambia-Kapardis, M.

    2007-01-01

    Full Text Available This paper identifies the reasons why glass ceiling and in the case of Cyprus “concrete ceiling” exists in both the private and public sectors despite enacted relevant legislation to ensure equality in work. Initially a qualitative research was carried out with the use of focus groups to identify the issues at hand. Following the results of the qualitative research, a questionnaire was prepared and distributed to the CEOs or the highest rank official of 120 organisations, 38% of those responded. This research, the first of its kind, addressed both the private and public sectors and confirms what has already been addressed in literature in other countries, namely that the main barrier hindering the career prospects of women is the family factor. In the public sector however where human intervention is eliminated women are better represented in the top-level positions.

  20. Women and Politics – The Glass Ceiling

    Directory of Open Access Journals (Sweden)

    Irina Zamfirache

    2010-03-01

    Full Text Available The role of women in modern politics is a subject that needs further insight, considering the growthin number of women that nowadays have relevant political positions on the international stage.There are studies today that emphasize the equality issue and all that is gender role related, but ourinterest is to analyze the women representation in power related positions. Due to the fastmodernization of the political environment and the rapid spreading of the feminist way of thought,several authors took interest in the gender differences in politics. The article follows some keydimensions in understanding the gender-role in politics: the glass ceiling, the role of the media indrawing the image of the woman politician, the gender affinity effect. In the end we would like topoint out the differences for men and women in exploiting the opportunities and securing the positions of power.

  1. INSUL, Calculation of Thermal Insulation of Various Materials Immersed in He

    International Nuclear Information System (INIS)

    Kinkead, A.N.; Pitchford, B.E.

    1977-01-01

    1 - Nature of the physical problem solved: Performance of thermal insulation immersed in helium. 2 - Method of solution: Mineral fibre, metal fibre and metallic multi-layer foils are studied. An approximate analysis for performance evaluation of multi-layer insulation in vertical gas spaces including the regime between fully suppressed natural convection and that for which an accepted power relationship applies is included

  2. Integrated Multilayer Insulation

    Science.gov (United States)

    Dye, Scott

    2009-01-01

    Integrated multilayer insulation (IMLI) is being developed as an improved alternative to conventional multilayer insulation (MLI), which is more than 50 years old. A typical conventional MLI blanket comprises between 10 and 120 metallized polymer films separated by polyester nets. MLI is the best thermal- insulation material for use in a vacuum, and is the insulation material of choice for spacecraft and cryogenic systems. However, conventional MLI has several disadvantages: It is difficult or impossible to maintain the desired value of gap distance between the film layers (and consequently, it is difficult or impossible to ensure consistent performance), and fabrication and installation are labor-intensive and difficult. The development of IMLI is intended to overcome these disadvantages to some extent and to offer some additional advantages over conventional MLI. The main difference between IMLI and conventional MLI lies in the method of maintaining the gaps between the film layers. In IMLI, the film layers are separated by what its developers call a micro-molded discrete matrix, which can be loosely characterized as consisting of arrays of highly engineered, small, lightweight, polymer (typically, thermoplastic) frames attached to, and placed between, the film layers. The term "micro-molded" refers to both the smallness of the frames and the fact that they are fabricated in a process that forms precise small features, described below, that are essential to attainment of the desired properties. The term "discrete" refers to the nature of the matrix as consisting of separate frames, in contradistinction to a unitary frame spanning entire volume of an insulation blanket.

  3. ASRM case insulation design and development

    Science.gov (United States)

    Bell, Matthew S.; Tam, William F. S.

    1992-10-01

    This paper describes the achievements made on the Advanced Solid Rocket Motor (ASRM) case insulation design and development program. The ASRM case insulation system described herein protects the metal case and joints from direct radiation and hot gas impingement. Critical failure of solid rocket systems is often traceable to failure of the insulation design. The wide ranging accomplishments included the development of a nonasbestos insulation material for ASRM that replaced the existing Redesigned Solid Rocket Motor (RSRM) asbestos-filled nitrile butadiene rubber (NBR) along with a performance gain of 300 pounds, and improved reliability of all the insulation joint designs, i.e., segmented case joint, case-to-nozzle and case-to-igniter joint. The insulation process development program included the internal stripwinding process. This process advancement allowed Aerojet to match to exceed the capability of other propulsion companies.

  4. A Simulation Study on the Performance of Radiant Ceilings Combined with Free-Hanging Horizontal Sound Absorbers

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Domínguez, L. Marcos; Rage, Niels

    2018-01-01

    using TABS, most building simulation models assume an uncovered ceiling; however, this might not be the case in practice, due to the use of free-hanging horizontal (or vertical) sound absorbers for the control of room acoustic conditions. The use of sound absorbers will decrease the performance...... of radiant ceiling cooling systems. Therefore, the quantification of the effects during the design phase is important for predicting the resulting thermal indoor environment and for system dimensioning. In this study, a two-person office room equipped with TABS was simulated using a commercially available...... simulation software with a recently developed plug-in that allows simulating the effects of horizontal sound absorbers on the performance of TABS and on the thermal indoor environment. The change in thermal indoor environment and in performance of TABS were quantified, and the simulation results were...

  5. Boundary layer theory approach to the concentration layer adjacent to the ceiling wall of a hydrogen leakage: Axisymmetric impinging and far regions

    Energy Technology Data Exchange (ETDEWEB)

    El-Amin, M.F.; Kanayama, H. [Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan)

    2009-02-15

    As hydrogen leaks into a partially open space with a ceiling wall, a boundary layer of hydrogen can be constructed under that wall due to the impingement on the wall and the buoyancy force. The resulting boundary layer can be divided into two regions, namely the stagnation-point region and the far region. When the geometry of the source of the hydrogen leak is circular, such as a pinhole or an o-ring, the behavior of leakage flow will be axisymmetric due to the resulting radial jet. In contrast, when the geometry of the source of the hydrogen leak is planar, such as a crack, the behavior of leakage flow will be planar due to the resulting planar jet. Previously, we studied the planar case in the context of both the stagnation-point flow region [El-Amin MF, Kanayama H. Boundary layer theory approach to the concentration layer adjacent to a ceiling wall at impinging region of a hydrogen leakage. Int J Hydrogen Energy 2008; 33(21): 6393-00] and the far region [El-Amin MF, Inoue M, Kanayama H. Boundary layer theory approach to the concentration layer adjacent to a ceiling wall of a hydrogen leakage: far region. Int J Hydrogen Energy 2008; 33(24):7642-7]. This paper is concerned with both the stagnation-point flow region and the far region of the axisymmetric concentration boundary layer adjacent to a ceiling wall. Flow in the stagnation-point region is treated as Hiemenz flow, while it is treated as Blasius flow in the far region. The current results are compared with the planar cases [El-Amin MF, Kanayama H. Boundary layer theory approach to the concentration layer adjacent to a ceiling wall at impinging region of a hydrogen leakage. Int J Hydrogen Energy 2008; 33(21): 6393-00; El-Amin MF, Inoue M, Kanayama H. Boundary layer theory approach to the concentration layer adjacent to a ceiling wall of a hydrogen leakage: far region. Int J Hydrogen Energy 2008; 33(24):7642-7] for both stagnation-point flow and far regions. Both momentum and concentration boundary layer

  6. Integrated Solution in an Office Room with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2015-01-01

    -scale experiments in a climate chamber. The experimental results indicate that diffuse ceiling can significantly improve thermal comfort in the occupied zone, by reducing draught risk and vertical temperature gradient. The linear function between pressure drop and air change rate points out that the air flow...

  7. The analysis of glass ceiling phenomenon in the promotion of women’s abilities in organizations

    Directory of Open Access Journals (Sweden)

    Mahboubeh Soleymanpour Omran

    2015-09-01

    Full Text Available Women constitute almost half of the workforce of a society and there has been considerable increase in women employment rate in recent years. However, their promotion to management positions has not been very tangible. Gender inequalities in the workplace especially in the domain of management have resulted in the lack of efficient use of potential capacities of women. Even though the previous research demonstrates that women are not less ambitious than men, wrong beliefs which attribute management to men make a kind of invisible barrier, known as glass ceiling, which prevents women’s promotion to top organizational positions. The purpose of this study was to investigate the reasons for the lack of promotion of women to top management levels in the society. It was conducted with a descriptive analytic method through the review of the related literature and emphasis on the concept of glass ceiling to present practical solutions to solve the problem.

  8. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation...

  9. Peak and ceiling effects in final-product analysis of mastoidectomy performance

    DEFF Research Database (Denmark)

    West, N; Konge, L; Cayé-Thomasen, P

    2015-01-01

    BACKGROUND: Virtual reality surgical simulation of mastoidectomy is a promising training tool for novices. Final-product analysis for assessing novice mastoidectomy performance could be limited by a peak or ceiling effect. These may be countered by simulator-integrated tutoring. METHODS: Twenty......-two participants completed a single session of self-directed practice of the mastoidectomy procedure in a virtual reality simulator. Participants were randomised for additional simulator-integrated tutoring. Performances were assessed at 10-minute intervals using final-product analysis. RESULTS: In all, 45.5 per...

  10. Forming Refractory Insulation On Copper Wire

    Science.gov (United States)

    Setlock, J.; Roberts, G.

    1995-01-01

    Alternative insulating process forms flexible coat of uncured refractory insulating material on copper wire. Coated wire formed into coil or other complex shape. Wire-coating apparatus forms "green" coat on copper wire. After wire coiled, heating converts "green" coat to refractory electrical insulator. When cured to final brittle form, insulating material withstands temperatures above melting temperature of wire. Process used to make coils for motors, solenoids, and other electrical devices to be operated at high temperatures.

  11. High-Performance Slab-on-Grade Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Mosiman, Garrett E. [NorthernSTAR, St. Paul, MN (United States)

    2015-09-01

    A more accurate assessment of slab-on-grade foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).

  12. The inaccuracy of heat transfer characteristics of insulated and non-insulated circular duct while neglecting the influence of heat radiation

    International Nuclear Information System (INIS)

    Hsien, T.-L.; Wong, K.-L.; Yu, S.-J.

    2009-01-01

    The non-insulated and insulated ducts are commonly applied in the industries and various buildings, because the heat radiation equation contains the 4th order exponential of temperature which is very complicate in calculations. Most heat transfer experts recognized from their own experiences that the heat radiation effect can be ignored due to the small temperature difference between insulated and non-insulated surface and surroundings. This paper studies in detail to check the inaccuracies of heat transfer characteristics non-insulated and insulated duct by comparing the results between considering and neglecting heat radiation effect. It is found that neglecting the heat radiation effect is likely to produce large errors of non-insulated and thin-insulated ducts in situations of ambient air with low external convection heat coefficients and larger surface emissivity, especially while the ambient air temperature is different from that of surroundings and greater internal fluid convection coefficients. It is also found in this paper that using greater duct surface emissivity can greatly improve the heat exchanger effect and using smaller insulated surface emissivity can obtain better insulation.

  13. Linear accelerator with x-ray absorbing insulators

    International Nuclear Information System (INIS)

    Rose, P.H.

    1975-01-01

    Annular insulators for supporting successive annular electrodes in a linear accelerator have embedded x-ray absorbing shield structures extending around the accelerating path. The shield members are disposed to intercept x-ray radiation without disrupting the insulative effect of the insulator members. In preferred forms, the structure comprises a plurality of annular members of heavy metal disposed in an x-ray blocking array, spaced from each other by the insulating substance of the insulator member. (auth)

  14. Insulator applications in a Tokamak reactor

    International Nuclear Information System (INIS)

    Leger, D.

    1986-06-01

    Insulators, among which insulators ceramics, have great potential applications in fusion reactors. They will be used for all plasma-facing components as protection and, magnetic fusion devices being subject to large electrical currents flowing in any parts of the device, for their electrical insulating properties

  15. Vacuum-insulated catalytic converter

    Science.gov (United States)

    Benson, David K.

    2001-01-01

    A catalytic converter has an inner canister that contains catalyst-coated substrates and an outer canister that encloses an annular, variable vacuum insulation chamber surrounding the inner canister. An annular tank containing phase-change material for heat storage and release is positioned in the variable vacuum insulation chamber a distance spaced part from the inner canister. A reversible hydrogen getter in the variable vacuum insulation chamber, preferably on a surface of the heat storage tank, releases hydrogen into the variable vacuum insulation chamber to conduct heat when the phase-change material is hot and absorbs the hydrogen to limit heat transfer to radiation when the phase-change material is cool. A porous zeolite trap in the inner canister absorbs and retains hydrocarbons from the exhaust gases when the catalyst-coated substrates and zeolite trap are cold and releases the hydrocarbons for reaction on the catalyst-coated substrate when the zeolite trap and catalyst-coated substrate get hot.

  16. Handleable shapes of thermal insulation material

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, J. T.

    1989-01-17

    Handleable and machineable shapes of thermal insulation material are made by compacting finely divided thermal insulation material into the cells of a reinforcing honeycomb insulation material into the cells of a reinforcing honeycomb structure. The finely divided thermal insulation material may be, for example, silica aerogel, pyrogenic silica, carbon black, silica gel, volatilised silica, calcium silicate, vermiculate or perlite, or finely divided metal oxides such as alumina or titania. The finely divided thermal insulation material may include an infra-red opacifier and/or reinforcing fibres. The reinforcing honeycomb structure may be made from, for example, metals such as aluminium foil, inorganic materials such as ceramics, organic materials such as plastics materials, woven fabrics or paper. A rigidiser may be employed. The shapes of thermal insulation material are substantially rigid and may be machines, for example by mechanical or laser cutting devices, or may be formed, for example by rolling, into curved or other shaped materials. 12 figs.

  17. Reusable Surface Insulation

    Science.gov (United States)

    1997-01-01

    Advanced Flexible Reusable Surface Insulation, developed by Ames Research Center, protects the Space Shuttle from the searing heat that engulfs it on reentry into the Earth's atmosphere. Initially integrated into the Space Shuttle by Rockwell International, production was transferred to Hi-Temp Insulation Inc. in 1974. Over the years, Hi-Temp has created many new technologies to meet the requirements of the Space Shuttle program. This expertise is also used commercially, including insulation blankets to cover aircrafts parts, fire barrier material to protect aircraft engine cowlings and aircraft rescue fire fighter suits. A Fire Protection Division has also been established, offering the first suit designed exclusively by and for aircraft rescue fire fighters. Hi-Temp is a supplier to the Los Angeles City Fire Department as well as other major U.S. civil and military fire departments.

  18. Translucent insulating building envelope

    DEFF Research Database (Denmark)

    Rahbek, Jens Eg

    1997-01-01

    A new type of translucent insulating material has been tested. This material is made of Celulose-Acetat and have a honey-comb structure. The material has a high solar transmittance and is highly insulating. The material is relatively cheap to produce. Danish Title: Translucent isolerende klimaskærm....

  19. Insulators for fusion applications

    International Nuclear Information System (INIS)

    1987-04-01

    Design studies for fusion devices and reactors have become more detailed in recent years and with this has come a better understanding of requirements and operating conditions for insulators in these machines. Ceramic and organic insulators are widely used for many components of fusion devices and reactors namely: radio frequency (RF) energy injection systems (BeO, Al 2 O 3 , Mg Al 2 O 4 , Si 3 N 4 ); electrical insulation for the torus structure (SiC, Al 2 O 3 , MgO, Mg Al 2 O 4 , Si 4 Al 2 O 2 N 6 , Si 3 N 4 , Y 2 O 3 ); lightly-shielded magnetic coils (MgO, MgAl 2 O 4 ); the toroidal field coil (epoxies, polyimides), neutron shield (B 4 C, TiH 2 ); high efficiency electrical generation; as well as the generation of very high temperatures for high efficiency hydrogen production processes (ZrO 2 and Al 2 O 3 - mat, graphite and carbon - felt). Timely development of insulators for fusion applications is clearly necessary. Those materials to be used in fusion machines should show high resistance to radiation damage and maintain their structural integrity. Now the need is urgent for a variety of radiation resistant materials, but much effort in these areas is required for insulators to be considered seriously by the design community. This document contains 14 papers from an IAEA meeting. It was the objective of this meeting to identify existing problems in analysing various situations of applications and requirements of electrical insulators and ceramics in fusion and to recommend strategies and different stages of implementation. This meeting was endorsed by the International Fusion Research Council

  20. Ceiling erosion in caves: early studies and Zdeněk Roth as author of the concept

    Czech Academy of Sciences Publication Activity Database

    Bella, P.; Bosák, Pavel

    2015-01-01

    Roč. 44, č. 1 (2015), s. 139-144 ISSN 0583-6050 Institutional support: RVO:67985831 Keywords : ceiling channel * paragenesis * antigravitative erosion * definition * Zdeněk Roth * Domica Cave * Slovak Karst Subject RIV: DB - Geology ; Mineralogy Impact factor: 0.792, year: 2015

  1. Does the Glass Ceiling Exist? A Longitudinal Study of Women’s Progress on French Corporate Boards

    OpenAIRE

    Rey Dang; Duc Khuong Nguyen; Linh-Chi Vo

    2014-01-01

    In this article, we conduct a longitudinal study of women’s progress on French corporate boards of directors. We particularly focus on the extent to which women directors have circumvented the glass ceiling. Using a sample of SBF 120 companies over a 10

  2. From (c)old house to an energy-saving house. Information on the energy conservation in the old building; Vom (K)althaus zum Energiesparhaus. Wissenswertes ueber die Energieeinsparung im Altbau

    Energy Technology Data Exchange (ETDEWEB)

    Eicke-Hennig, Werner; Fey, Klaus

    2013-04-01

    The contribution under consideration reports on energy savings opportunities for one- and two-family houses which account for a large part of the building stock. The halving of the consumption of heating energy is a clear message. With the following six steps, an energy efficient house can be attained from each house: insulation of the roof, insulation of exterior walls, new windows with heat-insulating glass, insulating of the basement ceiling, modernization of the heating system as by condensing boilers, power-saving circulating pump, solar water heating system.

  3. Asbestos Standard for the Construction Industry

    National Research Council Canada - National Science Library

    1995-01-01

    .... In the construction industry, asbestos is found in installed products such as shingles, floor tiles, cement pipe and sheet, roofing felts, insulation, ceiling tiles, fire-resistant drywall, and acoustical products...

  4. High Performance Slab-on-Grade Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Mosiman, Garrett E. [NorthernSTAR, St. Paul, MN (United States)

    2015-09-01

    ?A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 % for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.

  5. Field Study of Diffuse Ceiling Ventilation Performance in a Landscape Office

    DEFF Research Database (Denmark)

    Zukowska-Tejsen, Daria; Wolsing, Marie; Grysbæk, Malene

    2016-01-01

    show that diffuse ceiling ventilation has substantial potential for landscape office applications because it can provide important cooling capacity while maintaining an acceptable comfort level in the occupied zone. It does not generate draught in the occupied zone even at large temperature differences...... between supply and exhaust and great air change rates, while the same design parameters caused risk of draught in many points in the case with mixing ventilation. Good mixing in the occupied zone in case of both systems resulted in only small vertical temperature gradients. The results from the study...

  6. Process insulation. Isolation thermique des equipements

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    A manual is presented to assist managers and operating personnel to recognize industrial energy management opportunities, and provides mathematical equations, general information on proven techniques and technology, and examples. It deals with process insulation, focusing on the insulation of mechanical systems such as piping, process vessels, equipment, and ductwork. The manual describes the effects of insulation materials; commonly encountered types of insulation, coverings and protective finishes as well as common applications; energy management opportunities, divided into housekeeping, low cost, and retrofit; and includes worked examples of each. Includes glossary. 17 figs., 8 tabs.

  7. Metal-insulator transitions

    Science.gov (United States)

    Imada, Masatoshi; Fujimori, Atsushi; Tokura, Yoshinori

    1998-10-01

    Metal-insulator transitions are accompanied by huge resistivity changes, even over tens of orders of magnitude, and are widely observed in condensed-matter systems. This article presents the observations and current understanding of the metal-insulator transition with a pedagogical introduction to the subject. Especially important are the transitions driven by correlation effects associated with the electron-electron interaction. The insulating phase caused by the correlation effects is categorized as the Mott Insulator. Near the transition point the metallic state shows fluctuations and orderings in the spin, charge, and orbital degrees of freedom. The properties of these metals are frequently quite different from those of ordinary metals, as measured by transport, optical, and magnetic probes. The review first describes theoretical approaches to the unusual metallic states and to the metal-insulator transition. The Fermi-liquid theory treats the correlations that can be adiabatically connected with the noninteracting picture. Strong-coupling models that do not require Fermi-liquid behavior have also been developed. Much work has also been done on the scaling theory of the transition. A central issue for this review is the evaluation of these approaches in simple theoretical systems such as the Hubbard model and t-J models. Another key issue is strong competition among various orderings as in the interplay of spin and orbital fluctuations. Experimentally, the unusual properties of the metallic state near the insulating transition have been most extensively studied in d-electron systems. In particular, there is revived interest in transition-metal oxides, motivated by the epoch-making findings of high-temperature superconductivity in cuprates and colossal magnetoresistance in manganites. The article reviews the rich phenomena of anomalous metallicity, taking as examples Ti, V, Cr, Mn, Fe, Co, Ni, Cu, and Ru compounds. The diverse phenomena include strong spin and

  8. Labeling and advertising of home insulation

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-01

    This staff report, prepared by the F.T.C.'s Bureau of Consumer Protection for Commission review, includes recommendations as to the final form of a trade regulation rule relating to the labeling and advertising of home insulation. Because of marketing abuses which accompanied the rising demand for home insulation, there has been broad support for a rule requiring information disclosures to help purchasers of home insulation to make an informed decision. The Commission, to provide such rule as quickly as possible, undertook its rulemaking proceeding under its new expedited rulemaking procedure. The rule was proposed on November 18, 1977, and, following a two-month period for written comments, four weeks of hearings were held in Washington, D.C. in February 1978. The record, contributed to by a variety of interests, shows that consumers do not know how to shop for home insulation. The staff-recommended rule, among other things, would require that insulation be tested and R-values (a measure of insulation's ability to retain heat) disclosed on labels and in advertising. To facilitate comparison shopping, the industry would also be required to furnish consumers with fact sheets describing, on a product-to-product basis, factors that can reduce the R-value of insulation.

  9. Attic Retrofits Using Nail-Base Insulated Panels

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, David [Home Innovation Research Labs; Kochkin, Vladimir [Home Innovation Research Labs

    2018-03-26

    This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

  10. High performance thermal insulation systems (HiPTI). Vacuum insulated products (VIP). Proceedings of the international conference and workshop

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, M.; Bertschinger, H.

    2001-07-01

    These are the proceedings of the International Conference and Workshop held at EMPA Duebendorf, Switzerland, in January 2001. The papers presented at the conference's first day included contributions on the role of high-performance insulation in energy efficiency - providing an overview of available technologies and reviewing physical aspects of heat transfer and the development of thermal insulation as well as the state of the art of glazing technologies such as high-performance and vacuum glazing. Also, vacuum-insulated products (VIP) with fumed silica, applications of VIP systems in technical building systems, nanogels, VIP packaging materials and technologies, measurement of physical properties, VIP for advanced retrofit solutions for buildings and existing and future applications for advanced low energy building are discussed. Finally, research and development concerning VIP for buildings are reported on. The workshops held on the second day covered a preliminary study on high-performance thermal insulation materials with gastight porosity, flexible pipes with high performance thermal insulation, evaluation of modern insulation systems by simulation methods as well as the development of vacuum insulation panels with a stainless steel envelope.

  11. Design of Chern insulating phases in honeycomb lattices

    Science.gov (United States)

    Pickett, Warren E.; Lee, Kwan-Woo; Pentcheva, Rossitza

    2018-06-01

    The search for robust examples of the magnetic version of topological insulators, referred to as quantum anomalous Hall insulators or simply Chern insulators, so far lacks success. Our groups have explored two distinct possibilities based on multiorbital 3d oxide honeycomb lattices. Each has a Chern insulating phase near the ground state, but materials parameters were not appropriate to produce a viable Chern insulator. Further exploration of one of these classes, by substituting open shell 3d with 4d and 5d counterparts, has led to realistic prediction of Chern insulating ground states. Here we recount the design process, discussing the many energy scales that are active in participating (or resisting) the desired Chern insulator phase.

  12. Dielectric and Insulating Technology 2005 : Reviews & Forecasts

    Science.gov (United States)

    Okamoto, Tatsuki

    This article reports the state-of-art of TC-DEI ( Technical Committee of Dielectrics and Electrical Insulation of IEEJ) activites. The activiteis are basically based on the activites of 8-10 investigation committees under TC-DEI. Recent activites were categorized into three functions in this article and remarkable activity or trend for each category is mentioned as was done in the article of 2003. Thoese are activities on asset management (AI application and insulation diagnosis), activities on new insulating and functional materials (Nano composite) and activities on new insulation technology for power tansmission (high Tc superconducting cable insulation).

  13. Dielectric and Insulating Technology 2006 : Review & Forecast

    Science.gov (United States)

    Okamoto, Tatsuki

    This article reports the state-of-art of TC-DEI ( Technical Committee of Dielectrics and Electrical Insulation of IEEJ) activites. The activiteis are basically based on the activites of 8-10 investigation committees under TC-DEI. Recent activites were categorized into three functions in this article and remarkable activity or trend for each category is mentioned as was seen in the articles of 2005. Those are activities on asset management (AI application and insulation diagnosis), activities on new insulating and functional materials (Nano composite) and activities on new insulation technology for power tansmission (high Tc superconducting cable insulation).

  14. Improvements to the electrical insulation resistance of high quality magnesia insulated cables

    International Nuclear Information System (INIS)

    Mauger, R.A.; Goodings, A.

    1984-03-01

    Mineral insulated signal cables for nuclear reactor instrumentation schemes have to meet stringent electrical insulation requirements at high temperatures. This report discusses the factors which influence the attainment of this objective and the way in which it has been reached under industrial manufacturing conditions. It emphasises the importance of moisture and gives details of the improvements achieved as a result of moisture reduction. (author)

  15. Application of a permanent magnet biased E-Core reluctance actuator in a magnetically suspended ceiling actuator

    NARCIS (Netherlands)

    Overboom, T.T.; Jansen, J.W.; Lomonova, E.

    2010-01-01

    In the paper a novel actuator is presented for a magnetically suspended ceiling actuator. The actuator consists of several stator segments which contain the coils and the magnets. The armature, therefore, has a totally passive design. Because of its salient structure, a translational force can be

  16. Foam insulated transfer line test report

    International Nuclear Information System (INIS)

    Squier, D.M.

    1994-06-01

    Miles of underground insulated piping will be installed at the Hanford site to transfer liquid waste. Significant cost savings may be realized by using pre-fabricated polyurethane foam insulated piping. Measurements were made on sections of insulated pipe to determine the insulation's resistance to axial expansion of the pipe, the force required to compress the foam in the leg of an expansion loop and the time required for heat up and cool down of a buried piping loop. These measurements demonstrated that the peak axial force increases with the amount of adhesion between the encasement pipe and the insulation. The compressive strength of the foam is too great to accommodate the thermal growth of long straight pipe sections into the expansion loops. Mathematical models of the piping system's thermal behavior can be refined by data from the heated piping loop

  17. Lightweight, Thermally Insulating Structural Panels

    Science.gov (United States)

    Eisen, Howard J.; Hickey, Gregory; Wen, Liang-Chi; Layman, William E.; Rainen, Richard A.; Birur, Gajanana C.

    1996-01-01

    Lightweight, thermally insulating panels that also serve as structural members developed. Honeycomb-core panel filled with low-thermal-conductivity, opacified silica aerogel preventing convection and minimizes internal radiation. Copper coating on face sheets reduces radiation. Overall thermal conductivities of panels smaller than state-of-art commercial non-structurally-supporting foam and fibrous insulations. On Earth, panels suitable for use in low-air-pressure environments in which lightweight, compact, structurally supporting insulation needed; for example, aboard high-altitude aircraft or in partially evacuated panels in refrigerators.

  18. Aharonov–Bohm interference in topological insulator nanoribbons

    KAUST Repository

    Peng, Hailin; Lai, Keji; Kong, Desheng; Meister, Stefan; Chen, Yulin; Qi, Xiao-Liang; Zhang, Shou-Cheng; Shen, Zhi-Xun; Cui, Yi

    2009-01-01

    Topological insulators represent unusual phases of quantum matter with an insulating bulk gap and gapless edges or surface states. The two-dimensional topological insulator phase was predicted in HgTe quantum wells and confirmed by transport

  19. Optimization design for SST-1 Tokamak insulators

    International Nuclear Information System (INIS)

    Zhang Yuanbin; Pan Wanjiang

    2012-01-01

    With the help of ANSYS FEA technique, high voltage and cryogenic proper- ties of the SST-1 Tokamak insulators were obtained, and the structure of the insulators was designed and modified by taking into account the simulation results. The simulation results indicate that the optimization structure has better high voltage insulating property and cryogenic mechanics property, and also can fulfill the qualification criteria of the SST-1 Tokamak insulators. (authors)

  20. Numerical analysis of the potential of using light radiant ceilings in combination with diffuse ventilation to achieve thermal comfort in NZEB buildings

    DEFF Research Database (Denmark)

    Krusaa, Marie Rugholm; Hviid, Christian Anker; Kolarik, Jakub

    ceiling panels. These panels make it possible to combine the heating/cooling ceiling with the diffuse ventilation method. The diffuse ventilation method or leak ventilation use larger surfaces to provide air into the room instead of diffusers. An office building is investigated an analysed on an annual...... basis in the dynamic building simulation tool IDA Indoor Climate and Energy (IDA ICE). The office building contains both offices and meeting rooms. Worst-case scenarios are investigated in the office building considering heat gains, solar gains and the temperature offset between supply water temperature...

  1. Does Organizational Culture Affect the Perception Towards the Barriers of the Glass Ceiling?

    OpenAIRE

    Muruatetu, Ndunge

    2011-01-01

    Purpose : The purpose of this study was to examine the existence of the glass ceilling in Africa; and to investigate whether organizational culture affected the perception towards the barriers of the glass ceiling. Design/Methodology : This research used a quatitative approach, based on a descriptive design. Data was gathered from surveys issued to employees at a Non-Governmental organization; with the participants based in the Sierra Leone and Democratic Republic of Congo offices. Fi...

  2. Slab edge insulating form system and methods

    Science.gov (United States)

    Lee, Brain E [Corral de Tierra, CA; Barsun, Stephan K [Davis, CA; Bourne, Richard C [Davis, CA; Hoeschele, Marc A [Davis, CA; Springer, David A [Winters, CA

    2009-10-06

    A method of forming an insulated concrete foundation is provided comprising constructing a foundation frame, the frame comprising an insulating form having an opening, inserting a pocket former into the opening; placing concrete inside the foundation frame; and removing the pocket former after the placed concrete has set, wherein the concrete forms a pocket in the placed concrete that is accessible through the opening. The method may further comprise sealing the opening by placing a sealing plug or sealing material in the opening. A system for forming an insulated concrete foundation is provided comprising a plurality of interconnected insulating forms, the insulating forms having a rigid outer member protecting and encasing an insulating material, and at least one gripping lip extending outwardly from the outer member to provide a pest barrier. At least one insulating form has an opening into which a removable pocket former is inserted. The system may also provide a tension anchor positioned in the pocket former and a tendon connected to the tension anchor.

  3. High-performance insulator structures for accelerator applications

    International Nuclear Information System (INIS)

    Sampayan, S.E.; Caporaso, G.J.; Sanders, D.M.; Stoddard, R.D.; Trimble, D.O.; Elizondo, J.; Krogh, M.L.; Wieskamp, T.F.

    1997-05-01

    A new, high gradient insulator technology has been developed for accelerator systems. The concept involves the use of alternating layers of conductors and insulators with periods of order 1 mm or less. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We describe our ongoing studies investigating the degradation of the breakdown electric field resulting from alternate fabrication techniques, the effect of gas pressure, the effect of the insulator-to-electrode interface gap spacing, and the performance of the insulator structure under bi-polar stress

  4. Development of insulating coatings for liquid metal blankets

    International Nuclear Information System (INIS)

    Malang, S.; Borgstedt, H.U.; Farnum, E.H.; Natesan, K.; Vitkovski, I.V.

    1994-07-01

    It is shown that self-cooled liquid metal blankets are feasible only with electrically insulating coatings at the duct walls. The requirements on the insulation properties are estimated by simple analytical models. Candidate insulator materials are selected based on insulating properties and thermodynamic consideration. Different fabrication technologies for insulating coatings are described. The status of the knowledge on the most crucial feasibility issue, the degradation of the resisivity under irradiation, is reviewed

  5. Airflow Pattern and Performance Analysis of Diffuse Ceiling Ventilation in an Office Room using CFD Study

    DEFF Research Database (Denmark)

    Zhang, Chen; Chen, Qingyan; Heiselberg, Per Kvols

    2015-01-01

    geometrical model and the other is a porous media model. The numerical models are validated by the full-scale experimental studies in a climate chamber. The results indicate that porous media model performed better on predicting air flow characteristic below diffuse ceiling and air velocity near the floor...

  6. Plastic Materials for Insulating Applications.

    Science.gov (United States)

    Wang, S. F.; Grossman, S. J.

    1987-01-01

    Discusses the production and use of polymer materials as thermal insulators. Lists several materials that provide varying degrees of insulation. Describes the production of polymer foam and focuses on the major applications of polystyrene foam, polyurethane foam, and polyisocyanurate foam. (TW)

  7. Field evaluation of performance of radiant heating/cooling ceiling panel system

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    heating/coolingceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiantheating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus,this study aims to not only clarify the system performance but also to share our...... experience and our resultsfor them to serve as a reference for other similar projects. Here, the system performance in relation toits heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient fromwater to room was 3.7 W/(m2K) and 4.8 W/(m2K) for heating and cooling cases...

  8. Insulation Progress since the Mid-1950s

    Science.gov (United States)

    Timmerhaus, K. D.

    Storage vessel and cryostat design for modern cryogenic systems has become rather routine as the result of the wide use of and application of cryogenic fluids. Such vessels for these fluids range in size from 1 L flasks used in the laboratory for liquid nitrogen to the more than 200,000 m3 double-walled tanks used for temporary storage of liquefied natural gas before being transported overseas to their final destination. These storage vessels for cryogenic fluids range in type from low-performance containers insulated with rigid foam or fibrous insulation to high-performance containers insulated with evacuated multilayer insulations. The overriding factors in the type of container selected normally are of economics and safety. This paper will consider various insulation concepts used in such cryogenic storage systems and will review the progress that has been made over the past 50 years in these insulation systems.

  9. An Improved Prediction Model for the Impact Sound Level of Lightweight Floors: Introducing Decoupled Floor-Ceiling and Beam-Plate Moment

    DEFF Research Database (Denmark)

    Mosharrof, Mohammad Sazzad; Brunskog, Jonas; Ljunggren, Fredrik

    2011-01-01

    the impact sound pressure level in a receiving room for a coupled floor structure where floor and ceiling are rigidly connected by beams. A theoretical model for predicting the impact sound level for a decoupled floor structure, which has no rigid mechanical connections between the floor and the ceiling......, is developed. An analytical method has been implemented, where a spatial Fourier transform method as well as the Poisson’s sum formula is applied to model transformed plate displacements. Radiated sound power was calculated from these displacements and normalized sound pressure levels were calculated in one...... and is found to be dependent on frequency, showing significant improvement in predicting impact sound level at high frequency region....

  10. Reflecting variable opening insulating panel

    International Nuclear Information System (INIS)

    Nungesser, W.T.

    1976-01-01

    A description is given of a reflecting variable opening insulating panel assembly, comprising a static panel assembly of reflecting insulation sheets forming a cavity along one side of the panel and a movable panel opening out by sliding from the cavity of the static panel, and a locking device for holding the movable panel in a position extending from the cavity of the static panel. This can apply to a nuclear reactor of which the base might require maintenance and periodical checking and for which it is desirable to have available certain processes for the partial dismantling of the insulation [fr

  11. Electrical breakdown studies with Mycalex insulators

    International Nuclear Information System (INIS)

    Waldron, W.; Greenway, W.; Eylon, S.; Henestroza, E.; Yu, S.

    2003-01-01

    Insulating materials such as alumina and glass-bonded mica (Mycalex) are used in accelerator systems for high voltage feedthroughs, structural supports, and barriers between high voltage insulating oil and the vacuum beam pipe in induction accelerator cells. Electric fields in the triple points should be minimized to prevent voltage breakdown. Mechanical stress can compromise seals and result in oil contamination of the insulator surface. We have tested various insulator cleaning procedures including ultrasonic cleaning with a variety of aqueous-based detergents, and manual scrubbing with various detergents. Water sheeting tests were used to determine the initial results of the cleaning methods. Ultimately, voltage breakdown tests will be used to quantify the benefits of these cleaning procedures

  12. Topological insulators/superconductors: Potential future electronic materials

    International Nuclear Information System (INIS)

    Hor, Y. S.

    2014-01-01

    A new material called topological insulator has been discovered and becomes one of the fastest growing field in condensed matter physics. Topological insulator is a new quantum phase of matter which has Dirac-like conductivity on its surface, but bulk insulator through its interior. It is considered a challenging problem for the surface transport measurements because of dominant internal conductance due to imperfections of the existing crystals of topological insulators. By a proper method, the internal bulk conduction can be suppressed in a topological insulator, and permit the detection of the surface currents which is necessary for future fault-tolerant quantum computing applications. Doped topological insulators have depicted a large variety of bulk physical properties ranging from magnetic to superconducting behaviors. By chemical doping, a TI can change into a bulk superconductor. Nb x Bi 2 Se 3 is shown to be a superconductor with T c ∼ 3.2 K, which could be a potential candidate for a topological superconductor

  13. Sheath insulator final test report, TFE Verification Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications.

  14. Sheath insulator final test report, TFE Verification Program

    International Nuclear Information System (INIS)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications

  15. Proximity effects in topological insulator heterostructures

    International Nuclear Information System (INIS)

    Li Xiao-Guang; Wu Guang-Fen; Zhang Gu-Feng; Culcer Dimitrie; Zhang Zhen-Yu; Chen Hua

    2013-01-01

    Topological insulators (TIs) are bulk insulators that possess robust helical conducting states along their interfaces with conventional insulators. A tremendous research effort has recently been devoted to Tl-based heterostructures, in which conventional proximity effects give rise to a series of exotic physical phenomena. This paper reviews our recent studies on the potential existence of topological proximity effects at the interface between a topological insulator and a normal insulator or other topologically trivial systems. Using first-principles approaches, we have realized the tunability of the vertical location of the topological helical state via intriguing dual-proximity effects. To further elucidate the control parameters of this effect, we have used the graphene-based heterostructures as prototypical systems to reveal a more complete phase diagram. On the application side of the topological helical states, we have presented a catalysis example, where the topological helical state plays an essential role in facilitating surface reactions by serving as an effective electron bath. These discoveries lay the foundation for accurate manipulation of the real space properties of the topological helical state in TI-based heterostructures and pave the way for realization of the salient functionality of topological insulators in future device applications. (topical review - low-dimensional nanostructures and devices)

  16. Is a Widening Gender Wage Gap Necessarily Caused by a Glass Ceiling?

    OpenAIRE

    Staveren, Irene

    2012-01-01

    textabstractContrary to what is generally assumed, the gender wage gap and the glass ceiling may not necessarily be positively related. An exploratory analysis of aggregate public service personnel data for Uganda shows that the gender wage gap is small at the middle level of management, whereas it is twice as high at the top. At the same time, the share of women in top positions appears to be twice as high as at the middle ranks. Hence, it seems that in the context of a very patriarchal cult...

  17. Thermo-Insulation Properties Of Hemp-Based Products

    Directory of Open Access Journals (Sweden)

    Lekavicius V.

    2015-02-01

    Full Text Available As known, many multi-purpose plants can be used in different industries. This research is focused on the possibilities to utilize hemp as feedstock for thermal insulation products. The most advantageous features of hemp insulation are associated with health and environmental safety. The thermal conductivity of commercially available hemp insulation products is comparable with that of other fibrous insulation materials; however, it is possible to develop new products that could be more efficient in terms of cost and due to other important features.

  18. Dielectric and Insulating Technology 2004 : Review & Forecast

    Science.gov (United States)

    Okamoto, Tatsuki

    This article reports the state-of-art of DEIS activites. DEIS activiteis are basically based on the activites of 8-10 investigation committees’ under DEIS committee. Recent DEIS activites are categlized into three functions in this article and remarkable activity or trend of each category is mentioned. Those are activities on insulation diagnosis (AI application and asset management), activities on new insulation technology for power tansmission (high Tc super conducting cable insulation and all solid sinulated substation), and activities on new insulating materials (Nanocomposite).

  19. Corrosion-under-insulation (CUI) guidelines

    CERN Document Server

    Staff, European Federation of Corrosion; Winnik, S

    2014-01-01

    Corrosion under insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries. The European Federation of Corrosion (EFC) Working Parties WP13 and WP15 have worked to provide guidelines on managing CUI together with a number of major European refining, petrochemical and offshore companies including BP, Chevron-Texaco, Conoco-Phillips, ENI, Exxon-Mobil, IFP, MOL, Scanraff, Statoil, Shell, Total and Borealis. The guidelines within this document are intended for use on all plants and installations that contain insulated vessels, piping and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques (including n...

  20. Academe's Glass Ceiling: Societal, Professional-Organizational, and Institutional Barriers to the Career Advancement of Academic Women.

    Science.gov (United States)

    Bain, Olga; Cummings, William

    2000-01-01

    A survey of 10 national systems of higher education found that less than 10 percent of professors were women, and the proportion of female professors was negatively related to institutional prestige. This academic "glass ceiling" was related to women's shorter careers, tenure issues during hard times, and women's lower level of academic…

  1. Excavationless Exterior Foundation Insulation Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Schirber, T.; Mosiman, G.; Ojczyk, C.

    2014-10-01

    Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. However, such an approach can be very costly and disruptive when applied to an existing home, requiring deep excavation around the entire house. The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. The team was able to excavate a continuous 4" wide by 4' to 5' deep trench around the entire house, 128 linear feet, except for one small part under the stoop that was obstructed with concrete debris. The combination pressure washer and vacuum extraction technology also enabled the elimination of large trenches and soil stockpiles normally produced by backhoe excavation. The resulting trench was filled with liquid insulating foam, which also served as a water-control layer of the assembly. The insulation was brought above grade using a liquid foam/rigid foam hybrid system and terminated at the top of the rim joist. Cost savings over the traditional excavation process ranged from 23% to 50%. The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or non-existent in an excavationless process.

  2. Excavationless Exterior Foundation Insulation Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Schirber, T. [NorthernSTAR, Minneaplolis, MN (United States); Mosiman, G. [NorthernSTAR, Minneaplolis, MN (United States); Ojczyk, C. [NorthernSTAR, Minneaplolis, MN (United States)

    2014-09-01

    Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. However, such an approach can be very costly and disruptive when applied to an existing home, requiring deep excavation around the entire house. The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with liquid insulating foam. The team was able to excavate a continuous 4 inches wide by 4 feet to 5 feet deep trench around the entire house, 128 linear feet, except for one small part under the stoop that was obstructed with concrete debris. The combination pressure washer and vacuum extraction technology also enabled the elimination of large trenches and soil stockpiles normally produced by backhoe excavation. The resulting trench was filled with liquid insulating foam, which also served as a water-control layer of the assembly. The insulation was brought above grade using a liquid foam/rigid foam hybrid system and terminated at the top of the rim joist. Cost savings over the traditional excavation process ranged from 23% to 50%. The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or non-existent in an excavationless process.

  3. Insulation systems of the building construtions

    Directory of Open Access Journals (Sweden)

    Rumiantcev Boris

    2016-01-01

    Full Text Available Constructions of the exterior insulation and decoration combines materials of different functionality and constructive solutions allows to these materials to demonstrate their efficiency to the great extent. Fire safety of buildings is mandatory requirement for building systems. Some insulating material may belong to the group of combustible, but their use in structures so as to minimize the risk of fire. On the other hand, there are special designs, in which non-flammable insulation acts as a flame retardant barrier. In the article carried systematization of construction systems used in the flat and pitched roof during the insulation and wall covering and facades. Taking into account the experience of leading firms were considered the application features of using exterior finish systems: construction solutions, requirements for materials and recommendations about the installation these systems.The article deals with the construction ventilated roofing system of two types: flat roof and pitched roof seam. In the first case, the ventilation system is created using milled insulation boards in the second - by a ventilated gap. In both cases the natural convection of air in the air cavities. Ensuring operational stability insulation is laid on the stages of production of heat-insulating materials. It is important: firstly responsible execution of all process operations associated with providing regulatory properties of materials and secondly, the performance of additional operations associated with the produc-tion of materials, working in a specific design. An example of a material whose properties can modify for a particular application, are milled mineral wool (with air channels for systems of ventilated flat roof.

  4. Female healthcare managers and the glass ceiling. The obstacles and opportunities for women in management.

    Science.gov (United States)

    Wiggins, C

    1991-01-01

    Despite the large number of women in the healthcare field, healthcare management resembles other industries in its severe lack of women in upper-management positions and in the "glass ceiling" that contributes to this dearth. Although not enough has been specifically written on women healthcare managers, the author reviews what is available, along with some of the general management literature.

  5. Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation

    Science.gov (United States)

    Hess, David M.

    2013-01-01

    The primary application for cryogenic insulating foams will be fuel tank applications for fueling systems. It is crucial for this insulation to be incorporated into systems that survive vacuum and terrestrial environments. It is hypothesized that by forming an open-cell silica-reinforced polymer structure, the foam structures will exhibit the necessary strength to maintain shape. This will, in turn, maintain the insulating capabilities of the foam insulation. Besides mechanical stability in the form of crush resistance, it is important for these insulating materials to exhibit water penetration resistance. Hydrocarbon-terminated foam surfaces were implemented to impart hydrophobic functionality that apparently limits moisture penetration through the foam. During the freezing process, water accumulates on the surfaces of the foams. However, when hydrocarbon-terminated surfaces are present, water apparently beads and forms crystals, leading to less apparent accumulation. The object of this work is to develop inexpensive structural cryogenic insulation foam that has increased impact resistance for launch and ground-based cryogenic systems. Two parallel approaches will be pursued: a silica-polymer co-foaming technique and a post foam coating technique. Insulation characteristics, flexibility, and water uptake can be fine-tuned through the manipulation of the polyurethane foam scaffold. Silicate coatings for polyurethane foams and aerogel-impregnated polyurethane foams have been developed and tested. A highly porous aerogel-like material may be fabricated using a co-foam and coated foam techniques, and can insulate at liquid temperatures using the composite foam

  6. De Soweto à Ceilândia: siglas de segregação racial

    Directory of Open Access Journals (Sweden)

    Guilherme Oliveira Lemos

    2017-08-01

    Full Text Available A proposta desse trabalho é pensar relações comuns ou, pelo menos, aproximadas sobre os processos e os instrumentos de segregação urbana racial, generificada e social nas cidades de Soweto (Joanesburgo - África do Sul e Ceilândia (Distrito Federal - Brasil durante as décadas de 1950 e 1970. Para tanto, comparamos os dois processos de remoção das populações dos centros para as periferias e a (reinvenção dos tipos corpóreos (“candango”, “black”, “african”, “coloured” destinados a ocupar os limites da não-vida, ou seja, as  chamadas cidades satélites. Metodologicamente a pesquisa, de caráter inicial, fez-se através da análise indiciaria e comparativa de documentos oficiais, relatos orais e bibliografias referentes às duas cidades. A aproximação analítica/histórica entre esses casos se tornou possível através do conceito de necropolítica e da correlação entre escravidão, colonialismo e apartheid: três eventos imaginados historiograficamente como distintos, mas onde a dissociação do ser ao direito de sua própria vida rompem as barreiras do tempo e, no caso Soweto-Ceilândia, as fronteiras do Atlântico.

  7. Acoustic comfort in high-school classrooms for students and teachers

    NARCIS (Netherlands)

    G.E. Puglisi; L.C. Cantor Cutiva (Lady Catherine); L. Pavese; A. Castellana; M. Bona; S. Fasolis; V. Lorenzatti; A. Carullo; A. Burdor; F. Bronuzzi; A. Astolfi

    2015-01-01

    textabstractThis work focuses on the evaluation of acoustical quality in high-school classrooms through in-field measurements and self-reports. Two school buildings that differ in location and typology, were considered. In-field measurements included sound insulation, room acoustics and

  8. HgTe based topological insulators

    International Nuclear Information System (INIS)

    Bruene, Christoph

    2014-01-01

    This PhD thesis summarizes the discovery of topological insulators and highlights the developments on their experimental observations. The work focuses on HgTe. The thesis is structured as follows: - The first chapter of this thesis will give a brief overview on discoveries in the field of topological insulators. It focuses on works relevant to experimental results presented in the following chapters. This includes a short outline of the early predictions and a summary of important results concerning 2-dimensional topological insulators while the final section discusses observations concerning 3-dimensional topological insulators. - The discovery of the quantum spin Hall effect in HgTe marked the first experimental observation of a topological insulator. Chapter 2 focuses on HgTe quantum wells and the quantum spin Hall effect. The growth of high quality HgTe quantum wells was one of the major goals for this work. In a final set of experiments the spin polarization of the edge channels was investigated. Here, we could make use of the advantage that HgTe quantum well structures exhibit a large Rashba spin orbit splitting. - HgTe as a 3-dimensional topological insulator is presented in chapter 3. - Chapters 4-6 serve as in depth overviews of selected works: Chapter 4 presents a detailed overview on the all electrical detection of the spin Hall effect in HgTe quantum wells. The detection of the spin polarization of the quantum spin Hall effect is shown in chapter 5 and chapter 6 gives a detailed overview on the quantum Hall effect originating from the topological surface state in strained bulk HgTe.

  9. Coupling ant colony and the degraded ceiling algorithm for the redundancy allocation problem of series-parallel systems

    International Nuclear Information System (INIS)

    Nahas, Nabil; Nourelfath, Mustapha; Ait-Kadi, Daoud

    2007-01-01

    The redundancy allocation problem (RAP) is a well known NP-hard problem which involves the selection of elements and redundancy levels to maximize system reliability given various system-level constraints. As telecommunications and internet protocol networks, manufacturing and power systems are becoming more and more complex, while requiring short developments schedules and very high reliability, it is becoming increasingly important to develop efficient solutions to the RAP. This paper presents an efficient algorithm to solve this reliability optimization problem. The idea of a heuristic approach design is inspired from the ant colony meta-heuristic optimization method and the degraded ceiling local search technique. Our hybridization of the ant colony meta-heuristic with the degraded ceiling performs well and is competitive with the best-known heuristics for redundancy allocation. Numerical results for the 33 test problems from previous research are reported and compared. The solutions found by our approach are all better than or are in par with the well-known best solutions

  10. Innovative Retrofit Insulation Strategies for Concrete Masonry Foundations

    Energy Technology Data Exchange (ETDEWEB)

    Huelman, P. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Goldberg, L. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Jacobson, R. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2015-05-06

    This study was designed to test a new approach for foundation insulation retrofits, with the goal of demonstrating improved moisture control, improved occupant comfort, and reduced heat loss. Because conducting experimental research on existing below-grade assemblies is very difficult, most of the results are based on simulations. The retrofit approach consists of filling open concrete block cores with an insulating material and adding R-10 exterior insulation that extends 1 ft below grade. The core fill is designed to improve the R-value of the foundation wall and increase the interior wall surface temperature, but more importantly to block convection currents that could otherwise increase moisture loads on the foundation wall and interior space. The exterior insulation significantly reduces heat loss through the most exposed part of the foundation and further increases the interior wall surface temperature. This improves occupant comfort and decreases the risk of condensation. Such an insulation package avoids the full-depth excavation necessary for exterior insulation retrofits, reduces costs, and eliminates the moisture and indoor air quality risks associated with interior insulation retrofits. Retrofit costs for the proposed approach were estimated at roughly half those of a full-depth exterior insulation retrofit.

  11. Influence of Ceiling Suspended Screen Positioning to the Scatter Radiation Levels in Interventional Cardiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Bozovic, P.; Ciraj-Bjelac, O.; Antic, V.

    2013-01-01

    The objective of this paper is to identify the effects of the ceiling suspended screen position to the scatter radiation levels in the interventional cardiology. The scatter radiation in terms of ambient dose equivalent H * (10) was measured for various positions of protective screen in the positions of the first operator, nurse and radiographer, at elevations 100-190 cm and in four different angulations of the x-ray tube. To assess the effectiveness of the protective screen, the scattered dose was also measured in the absence of any protection in all four angulations and elevations. To simulate real clinical situation the measurements were performed in the presence of 30 cm PMMA phantom using standard clinical protocol. The utility of protective screen varied for different positions and angulations. Scatter radiation levels varied in the range 70 - 3400 μSv/h for the first operator, 140 - 3200 μSv/h for the nurse and 50 - 560 μSv/h for radiographer. Ceiling suspended screens can provide a substantial level of protection (up to factor 18) in interventional cardiology, but they have to be properly managed and positioned to achieve sufficient level of protection. The guidance for optimal protection is provided in the paper.(author)

  12. Load responsive multilayer insulation performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Dye, S.; Kopelove, A. [Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 (United States); Mills, G. L. [Ball Aerospace and Technologies Corp, 1600 Commerce Street, Boulder, CO 80301 (United States)

    2014-01-29

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

  13. Load responsive multilayer insulation performance testing

    International Nuclear Information System (INIS)

    Dye, S.; Kopelove, A.; Mills, G. L.

    2014-01-01

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI

  14. Defect design of insulation systems for photovoltaic modules

    Science.gov (United States)

    Mon, G. R.

    1981-01-01

    A defect-design approach to sizing electrical insulation systems for terrestrial photovoltaic modules is presented. It consists of gathering voltage-breakdown statistics on various thicknesses of candidate insulation films where, for a designated voltage, module failure probabilities for enumerated thickness and number-of-layer film combinations are calculated. Cost analysis then selects the most economical insulation system. A manufacturing yield problem is solved to exemplify the technique. Results for unaged Mylar suggest using fewer layers of thicker films. Defect design incorporates effects of flaws in optimal insulation system selection, and obviates choosing a tolerable failure rate, since the optimization process accomplishes that. Exposure to weathering and voltage stress reduces the voltage-withstanding capability of module insulation films. Defect design, applied to aged polyester films, promises to yield reliable, cost-optimal insulation systems.

  15. Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system--a human response study in hot and humid climate.

    Science.gov (United States)

    Yang, B; Sekhar, S C; Melikov, A K

    2010-08-01

    The benefits of thermal comfort and indoor air quality with personalized ventilation (PV) systems have been demonstrated in recent studies. One of the barriers for wide spread acceptance by architects and HVAC designers has been attributed to challenges and constraints faced in the integration of PV systems with the work station. A newly developed ceiling-mounted PV system addresses these challenges and provides a practical solution while retaining much of the apparent benefits of PV systems. Assessments of thermal environment, air movement, and air quality for ceiling-mounted PV system were performed with tropically acclimatized subjects in a Field Environmental Chamber. Thirty-two subjects performed normal office work and could choose to be exposed to four different PV airflow rates (4, 8, 12, and 16 L/s), thus offering themselves a reasonable degree of individual control. Ambient temperatures of 26 and 23.5 degrees C and PV air temperatures of 26, 23.5, and 21 degrees C were employed. The local and whole body thermal sensations were reduced when PV airflow rates were increased. Inhaled air temperature was perceived cooler and perceived air quality and air freshness improved when PV airflow rate was increased or temperature was reduced. The newly developed ceiling-mounted PV system offers a practical solution to the integration of PV air terminal devices (ATDs) in the vicinity of the workstation. By remotely locating the PV ATDs on the ceiling directly above the occupants and under their control, the conditioned outdoor air is now provided to the occupants through the downward momentum of the air. A secondary air-conditioning and air distribution system offers additional cooling in the room and maintains a higher ambient temperature, thus offering significant benefits in conserving energy. The results of this study provide designers and consultants with needed knowledge for design of PV systems.

  16. Measure Guideline. Hybrid Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2012-05-01

    This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a “partial drainage” detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

  17. Interaction between a pair of gypsy insulators or between heterologous gypsy and Wari insulators modulates Flp site-specific recombination in Drosophila melanogaster.

    Science.gov (United States)

    Krivega, Margarita; Savitskaya, Ekaterina; Krivega, Ivan; Karakozova, Marina; Parshikov, Aleksander; Golovnin, Anton; Georgiev, Pavel

    2010-08-01

    Chromatin insulators block the action of transcriptional enhancers when interposed between an enhancer and a promoter. An Flp technology was used to examine interactions between Drosophila gypsy and Wari insulators in somatic and germ cells. The gypsy insulator consists of 12 binding sites for the Su(Hw) protein, while the endogenous Wari insulator, located on the 3' side of the white gene, is independent from the Su(Hw) protein. Insertion of the gypsy but not Wari insulator between FRT sites strongly blocks recombination between Flp dimers bound to FRT sites located on the same chromatid (recombination in cis) or in sister chromatids (unequal recombination in trans). At the same time, the interaction between Wari and gypsy insulators regulates the efficiency of Flp-mediated recombination. Thus, insulators may have a role in controlling interactions between distantly located protein complexes (not only those involved in transcriptional gene regulation) on the same chromosome or on sister chromatids in somatic and germ cells. We have also found that the frequency of Flp-mediated recombination between FRT sites is strongly dependent on the relative orientation of gypsy insulators. Taken together, our results indicate that the interactions between insulators can be visualized by Flp technology and that insulators may be involved in blocking undesirable interactions between proteins at the two-chromatid phase of the cell cycle.

  18. Thresholds and Glass Ceilings: Career Pattern of Women Scientists

    Science.gov (United States)

    Sonnert, Gerhard

    2004-05-01

    The Project Access study examined the careers of men and women who had received prestigious postdoctoral fellowships and thus were presumably of about equal promise at the start of their professional careers. Had the women scientists in this elite group overcome a threshold beyond which they proceeded on equal footing with their male counterparts; or did a glass ceiling impede their careers? We found gender differences in career outcomes in the group we studied (699 questionnaires, 200 interviews), but these differences varied considerably by scientific discipline. Moreover, the career disparities for women, as a group, appear now to result chiefly from a series of subtle but identifiable and sometimes counterintuitive impediments as well as from slight gender differences in socialization. Each disadvantage by itself may be small, but in their accumulation they significantly influence women's careers.

  19. The glass ceiling and women in management in the Middle East: Myth or reality

    OpenAIRE

    Marinakou, Evangelia

    2014-01-01

    Although globalization and equal employment have created opportunities for female managers, they are still underrepresented in the corporate ladder. Gender and gender role stereotypes are persistent in organizations that operate in the Middle East, challenging women’s employment and showing evidence of the glass ceiling in management. This paper explores the position of women in management in the Kingdom of Bahrain, as well as the barriers they face in climbing the career ladder. The findings...

  20. Modeling of Dynamic Responses in Building Insulation

    Directory of Open Access Journals (Sweden)

    Anna Antonyová

    2015-10-01

    Full Text Available In this research a measurement systemwas developedfor monitoring humidity and temperature in the cavity between the wall and the insulating material in the building envelope. This new technology does not disturb the insulating material during testing. The measurement system can also be applied to insulation fixed ten or twenty years earlier and sufficiently reveals the quality of the insulation. A mathematical model is proposed to characterize the dynamic responses in the cavity between the wall and the building insulation as influenced by weather conditions.These dynamic responses are manifested as a delay of both humidity and temperature changes in the cavity when compared with the changes in the ambient surrounding of the building. The process is then modeled through numerical methods and statistical analysis of the experimental data obtained using the new system of measurement.

  1. Electrical insulator requirements for mirror fusion reactors

    International Nuclear Information System (INIS)

    Condit, R.H.; Van Konynenburg, R.A.

    1977-01-01

    The requirements for mirror fusion electrical insulators are discussed. Insulators will be required at the neutral beam injectors, injector power supplies, direct converters, and superconducting magnets. Insulators placed at the neutral beam injectors will receive the greatest radiation exposure, 10 14 to 10 16 neutrons/m 2 .s and 0.3 to 3 Gy/s (10 5 to 10 6 R/h) of gamma rays, with shielding. Direct converter insulators may receive the highest temperature (up to 1300 0 K), but low voltage holding requirements. Insulators made from organic materials (e.g., plastics) for the magnet coils may be satisfactory. Immediate conductivity increases of all insulators result from gamma irradiation. With an upper limit to gamma flux exposures of 300 Gy/s in a minimally shielded region, the conductivity could reach 10 -6 S/m. Damage from neutron irradiation may not be serious during several years' exposure. Surface changes in ceramics at the neutral beam injector may be serious. The interior of the injector will contain atomic hydrogen, and sputtering may transfer material away from or onto the ceramic insulators. Unknown and potentially damaging interactions between irradiation, electric fields, temperature gradients, cycling of temperature, surface and joint reactions, sputtering, polarization, and electrotransport in the dielectrics are of concern. Materials research to deal with these problems is needed

  2. Measure Guideline: Hybrid Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Lstiburek, J.

    2012-05-01

    This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

  3. Experimental study of diffuse ceiling ventilation coupled with a thermally activated building construction in an office room

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2015-01-01

    the opposite effect on energy performance when TABS is activated in heating or cooling mode. Finally, the air temperature distribution in the plenum and the surface temperature distribution of the diffuse ceiling point out that the air does not perfectly mix in the plenum, the air is not evenly distributed...

  4. 49 CFR 236.527 - Roadway element insulation resistance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Roadway element insulation resistance. 236.527 Section 236.527 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... element insulation resistance. Insulation resistance between roadway inductor and ground shall be...

  5. Inside Story: A Guide to Indoor Air Quality

    Science.gov (United States)

    ... finish a basement below ground level unless all water leaks are patched and outdoor ventilation and adequate heat ... smoke; asbestos from insulating and fire-retardant building supplies; formaldehyde ... or water-damaged walls, ceilings, and carpets; and pesticides from ...

  6. Thermal-Insulation Properties of Multilayer Textile Packages

    Directory of Open Access Journals (Sweden)

    Matusiak Małgorzata

    2014-12-01

    Full Text Available Thermal-insulation properties of textile materials play a significant role in material engineering of protective clothing. Thermal-insulation properties are very important from the point of view of thermal comfort of the clothing user as well as the protective efficiency against low or high temperature. Thermal protective clothing usually is a multilayer construction. Its thermal insulation is a resultant of a number of layers and their order, as well as the thermalinsulation properties of a single textile material creating particular layers. The aim of the presented work was to investigate the relationships between the thermal-insulation properties of single materials and multilayer textile packages composed of these materials. Measurement of the thermal-insulation properties of single and multilayer textile materials has been performed with the Alambeta. The following properties have been investigated: thermal conductivity, resistance and absorptivity. Investigated textile packages were composed of two, three and four layers made of woven and knitted fabrics, as well as nonwovens. On the basis of the obtained results an analysis has been carried out in order to assess the dependency of the resultant values of the thermal-insulation properties of multilayer packages on the appropriate values of particular components.

  7. Topological Insulators Dirac Equation in Condensed Matters

    CERN Document Server

    Shen, Shun-Qing

    2012-01-01

    Topological insulators are insulating in the bulk, but process metallic states around its boundary owing to the topological origin of the band structure. The metallic edge or surface states are immune to weak disorder or impurities, and robust against the deformation of the system geometry. This book, Topological insulators, presents a unified description of topological insulators from one to three dimensions based on the modified Dirac equation. A series of solutions of the bound states near the boundary are derived, and the existing conditions of these solutions are described. Topological invariants and their applications to a variety of systems from one-dimensional polyacetalene, to two-dimensional quantum spin Hall effect and p-wave superconductors, and three-dimensional topological insulators and superconductors or superfluids are introduced, helping readers to better understand this fascinating new field. This book is intended for researchers and graduate students working in the field of topological in...

  8. KSI's Cross Insulated Core Transformer Technology

    International Nuclear Information System (INIS)

    Uhmeyer, Uwe

    2009-01-01

    Cross Insulated Core Transformer (CCT) technology improves on Insulated Core Transformer (ICT) implementations. ICT systems are widely used in very high voltage, high power, power supply systems. In an ICT transformer ferrite core sections are insulated from their neighboring ferrite cores. Flux leakage is present at each of these insulated gaps. The flux loss is raised to the power of stages in the ICT design causing output voltage efficiency to taper off with increasing stages. KSI's CCT technology utilizes a patented technique to compensate the flux loss at each stage of an ICT system. Design equations to calculate the flux compensation capacitor value are presented. CCT provides corona free operation of the HV stack. KSI's CCT based High Voltage power supply systems offer high efficiency operation, high frequency switching, low stored energy and smaller size over comparable ICT systems.

  9. Grandstand view of phenolic foam insulation

    Energy Technology Data Exchange (ETDEWEB)

    1987-03-01

    Stadium Insulation Ltd, manufacture pipe sections, tank and vessel insulation products in Lowphen, polyisocyanurate, polyurethane foams and expanded polystyrene, though for certain specialist applications, cork is still employed in small quantities. Currently the emphasis is very much on Lowphen, the company's range of pipe sections based on phenolic foam. The company's manufacturing and marketing effort reflects the increasing market trend towards the use of insulating material capable of withstanding higher temperatures, and phenolic foam neatly satisfies the demand since it is capable of use at temperatures up to 140/sup 0/C. Moreover, phenolic foam has the lowest K value at 0.02W/m/sup 0/C of any of the currently available range of insulating materials, and while the product is slightly more expensive than alternatives such as polyisocyanurate and polyurethane, its high performance offsets that premium.

  10. Method of manufacturing a thermally insulating body

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, J.A.; Morgan, D.E.; Jackson, J.D.

    1988-10-11

    A method of manufacturing a microporous thermally insulating body comprises mixing together a finely divided microporous insulating material such as silica aerogel or pyrogenic silica and a solid ammonia-generating compound in particulate form, and compressing the mixture to form a thermally insulating body. The ammonia-generating compound is dispersed evenly throughout the insulating material and may comprise, for example, ammonium carbonate, ammonium acetate or urea. Preferably, the ammonia-generating compound comprises a mixture of about one third by weight of ammonium carbonate and about two thirds by weight of ammonium bicarbonate together with a small proportion of magnesium oxide. Experiments are described which illustrate the manufacturing process. 6 tabs.

  11. Compact gas-insulated transformer. Fourteenth quarterly report

    Energy Technology Data Exchange (ETDEWEB)

    1983-08-01

    Objective is to develop a compact, more efficient, quieter transformer which does not rely on mineral oil insulation. Compressed SF/sub 6/ is used as the external insulation and polymer film as the insulation between turns. A separate liquid cooling system is also provided. This document reports progress made in design, mechanical, dielectric, short circuit, thermal, materials, prototype, accessories, commercialization, and system studies. (DLC)

  12. [Attempt to reduce the formaldehyde concentration by blowing cooled fresh air down in to the breathing zone of medical students from an admission port on the ceiling during gross anatomy class].

    Science.gov (United States)

    Takayanagi, Masaaki; Sakai, Makoto; Ishikawa, Youichi; Murakami, Kunio; Kimura, Akihiko; Kakuta, Sachiko; Sato, Fumi

    2008-09-01

    Cadavers in gross anatomy laboratories at most medical schools are conventionally embalmed in formaldehyde solution, which is carcinogenic to humans. Medical students and instructors are thus exposed to formaldehyde vapors emitted from cadavers during dissection. To reduce high formaldehyde concentrations in the breathing zone above cadavers being examined by anatomy medical students provisionally, dissection beds were located under existing admission ports on the ceiling to supply cooled fresh air from the admission port blowing downward on to the cadaver. In all cases, compared to normal condition, the downward flow of cooled fresh air from an admission port reduced formaldehyde concentrations by 0.09-0.98 ppm and reduced to 12.6-65.4% in the air above a cadaver in the breathing zone of students. The formaldehyde concentrations above cadavers under admission ports were not more than the formaldehyde concentrations between beds representing the indoor formaldehyde concentrations. Although the application of an existing admission port on the ceiling in this study did not remove formaldehyde, the downflow of cooled fresh air using this system reduced the formaldehyde concentration in the air above cadavers being attended by anatomy students during dissections. These results suggest the need for reducing formaldehyde levels in gross anatomy laboratories using fundamental countermeasures in order to satisfy the guidelines of 0.08 ppm established by the World Health Organization and the Japan Ministry of Health, Labor and Welfare.

  13. Quantitative analysis of thermal insulation coatings

    DEFF Research Database (Denmark)

    Kiil, Søren

    2014-01-01

    This work concerns the development of simulation tools for mapping of insulation properties of thermal insulation coatings based on selected functional filler materials. A mathematical model, which includes the underlying physics (i.e. thermal conductivity of a heterogeneous two-component coating...

  14. Thermal insulation of high temperature reactors

    International Nuclear Information System (INIS)

    Cornille, Y.

    1975-01-01

    Operating conditions of HTR thermal insulation are given and heat insulators currently developed are described (fibers kept in position by metallic structures). For future applications and higher temperatures, research is directed towards solutions using ceramics or associating fibers and ceramics [fr

  15. Vacuum insulation - Panel properties and building applications. HiPTI - High Performance Thermal Insulation - IEA/ECBCS Annex 39 - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Erb, M. (ed.)

    2005-12-15

    This paper takes a look at the properties of vacuum insulation panels (VIP) that have already been developed some time ago for use in appliances such as refrigerators and deep-freezers. Their insulation performance is a factor of five to ten times better than that of conventional insulation. The paper discusses the use of such panels in buildings to provide thin, highly-insulating constructions for walls, roofs and floors. The motivation for examining the applicability of high performance thermal insulation in buildings is discussed, including solutions where severe space limitations and other technical and aesthetic considerations exist. The use of nano-structured materials and laminated foils is examined and discussed. The questions arising from the use of such panels in buildings is discussed and the open questions and risks involved are examined. Finally, an outlook on the introduction of VIP technology is presented and quality assurance aspects are examined. This work was done within the framework of the Task 39 'High Performance Thermal Insulation' of the 'Energy Conservation in Buildings and Community Systems ECBCS' programme of the International Energy Agency IEA.

  16. Composite Behavior of a Novel Insulated Concrete Sandwich Wall Panel Reinforced with GFRP Shear Grids: Effects of Insulation Types.

    Science.gov (United States)

    Kim, JunHee; You, Young-Chan

    2015-03-03

    A full-scale experimental program was used in this study to investigate the structural behavior of novel insulated concrete sandwich wall panels (SWPs) reinforced with grid-type glass-fiber-reinforced polymer (GFRP) shear connectors. Two kinds of insulation-expanded polystyrene (EPS) and extruded polystyrene (XPS) with 100 mm thickness were incased between the two concrete wythes to meet the increasing demand for the insulation performance of building envelope. One to four GFRP shear grids were used to examine the degree of composite action of the two concrete wythes. Ten specimens of SWPs were tested under displacement control subjected to four-point concentrated loads. The test results showed that the SWPs reinforced with GFRP grids as shear connectors developed a high degree of composite action resulting in high flexural strength. The specimens with EPS foam exhibited an enhanced load-displacement behavior compared with the specimens with XPS because of the relatively stronger bond between insulation and concrete. In addition, the ultimate strength of the test results was compared to the analytical prediction with the mechanical properties of only GRFP grids. The specimens with EPS insulation presented higher strength-based composite action than the ones with XPS insulation.

  17. Insulators form gene loops by interacting with promoters in Drosophila.

    Science.gov (United States)

    Erokhin, Maksim; Davydova, Anna; Kyrchanova, Olga; Parshikov, Alexander; Georgiev, Pavel; Chetverina, Darya

    2011-09-01

    Chromatin insulators are regulatory elements involved in the modulation of enhancer-promoter communication. The 1A2 and Wari insulators are located immediately downstream of the Drosophila yellow and white genes, respectively. Using an assay based on the yeast GAL4 activator, we have found that both insulators are able to interact with their target promoters in transgenic lines, forming gene loops. The existence of an insulator-promoter loop is confirmed by the fact that insulator proteins could be detected on the promoter only in the presence of an insulator in the transgene. The upstream promoter regions, which are required for long-distance stimulation by enhancers, are not essential for promoter-insulator interactions. Both insulators support basal activity of the yellow and white promoters in eyes. Thus, the ability of insulators to interact with promoters might play an important role in the regulation of basal gene transcription.

  18. Geomorphometric analysis of cave ceiling channels mapped with 3-D terrestrial laser scanning

    Science.gov (United States)

    Gallay, Michal; Hochmuth, Zdenko; Kaňuk, Ján; Hofierka, Jaroslav

    2016-05-01

    The change of hydrological conditions during the evolution of caves in carbonate rocks often results in a complex subterranean geomorphology, which comprises specific landforms such as ceiling channels, anastomosing half tubes, or speleothems organized vertically in different levels. Studying such complex environments traditionally requires tedious mapping; however, this is being replaced with terrestrial laser scanning technology. Laser scanning overcomes the problem of reaching high ceilings, providing new options to map underground landscapes with unprecedented level of detail and accuracy. The acquired point cloud can be handled conveniently with dedicated software, but applying traditional geomorphometry to analyse the cave surface is limited. This is because geomorphometry has been focused on parameterization and analysis of surficial terrain. The theoretical and methodological concept has been based on two-dimensional (2-D) scalar fields, which are sufficient for most cases of the surficial terrain. The terrain surface is modelled with a bivariate function of altitude (elevation) and represented by a raster digital elevation model. However, the cave is a 3-D entity; therefore, a different approach is required for geomorphometric analysis. In this paper, we demonstrate the benefits of high-resolution cave mapping and 3-D modelling to better understand the palaeohydrography of the Domica cave in Slovakia. This methodological approach adopted traditional geomorphometric methods in a unique manner and also new methods used in 3-D computer graphics, which can be applied to study other 3-D geomorphological forms.

  19. Women's participation in parliament: 'Glass ceiling' syndrome and party selection

    Directory of Open Access Journals (Sweden)

    Čičkarić Lilijana

    2014-01-01

    Full Text Available The impact of 'glass ceiling' syndrome and party selection on participation of women in parliament and other political institutions are examined in this article. 'Glass ceiling' syndrome, which means invisible, but almost impenetrable border that women face in professional life, keeping them away from positions of influence and progress in career, is the main reason for the small number of women involved in politics. According to the focus of the research, there are three groups of barriers to women's political participation. Most researchers examine the influence of the political system, institutional and legal mechanisms, the question of their transparency and functional improvement. Significantly less frequent approach came from authors who are concentrated on the social and economic barriers, financial conditions and the broader social context. The third group consists of those who are considering the ideological and psychological barriers, patriarchal cultural patterns, traditional gender roles, self-confidence, ambition and women's desire to be involved in politics. Political parties are key actors in the process of discrimination against women, because they do not allow them to be selected in a number of political functions. There are many factors that determine that the issue of gender equality is variously interpreted in political parties. The most present are contextual and ideological factors, referring to a different definition of the status of women on the political agenda, the social climate in terms of gender equality and respect for human rights, the level of social development and political freedom. Then come organizational factors pertaining to the structure of parties, the manner in which the leadership is elected, whether there are internal women's pressure groups and lobbying, and are women leaders are visible on high positions in decision-making process. Finally, there are institutional-legal factors, which include the type

  20. Insulation Characteristics of Sisal Fibre/Epoxy Composites

    Directory of Open Access Journals (Sweden)

    A. Shalwan

    2017-01-01

    Full Text Available Using natural fibres in civil engineering is the aim of many industrial and academics sectors to overcome the impact of synthetic fibres on environments. One of the potential applications of natural fibres composites is to be implemented in insulation components. Thermal behaviour of polymer composites based on natural fibres is recent ongoing research. In this article, thermal characteristics of sisal fibre reinforced epoxy composites are evaluated for treated and untreated fibres considering different volume fractions of 0–30%. The results revealed that the increase in the fibre volume fraction increased the insulation performance of the composites for both treated and untreated fibres. More than 200% insulation rate was achieved at the volume fraction of 20% of treated sisal fibres. Untreated fibres showed about 400% insulation rate; however, it is not recommended to use untreated fibres from mechanical point of view. The results indicated that there is potential of using the developed composites for insulation purposes.

  1. Polyester Apparel Cutting Waste as Insulation Material

    OpenAIRE

    Trajković, Dušan; Jordeva, Sonja; Tomovska, Elena; Zafirova, Koleta

    2017-01-01

    Polyester waste is the dominant component of the clothing industry waste stream, yet its recycling in this industry is rarely addressed. This paper proposes using polyester cutting waste as an insulation blanket for roofing and buildings’ internal walls in order to reduce environmental pollution. The designed textile structures used waste cuttings from different polyester fabrics without opening the fabric to fibre. Thermal insulation, acoustic insulation, fire resistance and biodegradation o...

  2. Economical evaluation of damaged vacuum insulation panels in buildings

    Science.gov (United States)

    Kim, Y. M.; Lee, H. Y.; Choi, G. S.; Kang, J. S.

    2015-12-01

    In Korea, thermal insulation standard of buildings have been tightened annually to satisfy the passive house standard from the year 2009. The current domestic policies about disseminating green buildings are progressively conducted. All buildings should be the zero energy building in the year 2025, obligatorily. The method is applied to one of the key technologies for high-performance insulation for zero energy building. The vacuum insulation panel is an excellent high performance insulation. But thermal performance of damaged vacuum insulation panels is reduced significantly. In this paper, the thermal performance of damaged vacuum insulation panels was compared and analyzed. The measurement result of thermal performance depends on the core material type. The insulation of building envelope is usually selected by economic feasibility. To evaluate the economic feasibility of VIPs, the operation cost was analyzed by simulation according to the types and damaged ratio of VIPs

  3. Cooling ceilings: Silent, comfortable and productive. Percentage of sickness absenteeism. Kuehldecken eroeffnen neue Moeglichkeiten: Still, behaglich und produktiv. Krankenstand von 11,8 auf 3,8% reduziert

    Energy Technology Data Exchange (ETDEWEB)

    Laege, F.K.

    1992-07-01

    This article is a report about the second symposium on cooling ceilings held in Essen, which had been organized by the technical institute for building ventilation. On the one hand the topic was the state of technology as well as the standardization have been treated, on the other hand, user experiences of non technicians have been reported. It was ascertained that the variety of references convinced the auditors. Germany has obviously the leading position for the construction of cooling ceilings. (BWI).

  4. Super-insulation

    International Nuclear Information System (INIS)

    Gerold, J.

    1985-01-01

    The invention concerns super-insulation, which also acts as spacing between two pressurized surfaces, where the crossing bars in at least two layers are provided, with interposed foil. The super-insulation is designed so that it can take compression forces and limits thermal radiation and thermal conduction sufficiently, where the total density of heat flow is usually limited to a few watts per m 2 . The solution to the problem is characterized by the fact that the bars per layer are parallel and from layer to layer they are at an angle to each other and the crossover positions of the bars of different layers are at fixed places and so form contact columns. The basic idea is that bars crossing over each other to support compression forces are used so that contact columns are formed, which are compressed to a certain extent by the load. (orig./PW) [de

  5. On effective holographic Mott insulators

    Energy Technology Data Exchange (ETDEWEB)

    Baggioli, Matteo; Pujolàs, Oriol [Institut de Física d’Altes Energies (IFAE), Universitat Autònoma de Barcelona,The Barcelona Institute of Science and Technology,Campus UAB, 08193 Bellaterra (Barcelona) (Spain)

    2016-12-20

    We present a class of holographic models that behave effectively as prototypes of Mott insulators — materials where electron-electron interactions dominate transport phenomena. The main ingredient in the gravity dual is that the gauge-field dynamics contains self-interactions by way of a particular type of non-linear electrodynamics. The electrical response in these models exhibits typical features of Mott-like states: i) the low-temperature DC conductivity is unboundedly low; ii) metal-insulator transitions appear by varying various parameters; iii) for large enough self-interaction strength, the conductivity can even decrease with increasing doping (density of carriers) — which appears as a sharp manifestation of ‘traffic-jam’-like behaviour; iv) the insulating state becomes very unstable towards superconductivity at large enough doping. We exhibit some of the properties of the resulting insulator-superconductor transition, which is sensitive to the momentum dissipation rate in a specific way. These models imply a clear and generic correlation between Mott behaviour and significant effects in the nonlinear electrical response. We compute the nonlinear current-voltage curve in our model and find that indeed at large voltage the conductivity is largely reduced.

  6. Improved DC Gun Insulator Assembly

    International Nuclear Information System (INIS)

    Neubauer, M.L.; Dudas, A.; Sah, R.; Poelker, M.; Surles-Law, K.E.L.

    2010-01-01

    Many user facilities such as synchrotron radiation light sources and free electron lasers require accelerating structures that support electric fields of 10-100 MV/m, especially at the start of the accelerator chain where ceramic insulators are used for very high gradient DC guns. These insulators are difficult to manufacture, require long commissioning times, and often exhibit poor reliability. Two technical approaches to solving this problem will be investigated. Firstly, inverted ceramics offer solutions for reduced gradients between the electrodes and ground. An inverted design will be presented for 350 kV, with maximum gradients in the range of 5-10 MV/m. Secondly, novel ceramic manufacturing processes will be studied, in order to protect triple junction locations from emission, by applying a coating with a bulk resistivity. The processes for creating this coating will be optimized to provide protection as well as be used to coat a ceramic with an appropriate gradient in bulk resistivity from the vacuum side to the air side of an HV standoff ceramic cylinder. Example insulator designs are being computer modelled, and insulator samples are being manufactured and tested

  7. On effective holographic Mott insulators

    International Nuclear Information System (INIS)

    Baggioli, Matteo; Pujolàs, Oriol

    2016-01-01

    We present a class of holographic models that behave effectively as prototypes of Mott insulators — materials where electron-electron interactions dominate transport phenomena. The main ingredient in the gravity dual is that the gauge-field dynamics contains self-interactions by way of a particular type of non-linear electrodynamics. The electrical response in these models exhibits typical features of Mott-like states: i) the low-temperature DC conductivity is unboundedly low; ii) metal-insulator transitions appear by varying various parameters; iii) for large enough self-interaction strength, the conductivity can even decrease with increasing doping (density of carriers) — which appears as a sharp manifestation of ‘traffic-jam’-like behaviour; iv) the insulating state becomes very unstable towards superconductivity at large enough doping. We exhibit some of the properties of the resulting insulator-superconductor transition, which is sensitive to the momentum dissipation rate in a specific way. These models imply a clear and generic correlation between Mott behaviour and significant effects in the nonlinear electrical response. We compute the nonlinear current-voltage curve in our model and find that indeed at large voltage the conductivity is largely reduced.

  8. Compact vacuum insulation

    Science.gov (United States)

    Benson, D.K.; Potter, T.F.

    1993-01-05

    An ultra-thin compact vacuum insulation panel is comprised of two hard, but bendable metal wall sheets closely spaced apart from each other and welded around the edges to enclose a vacuum chamber. Glass or ceramic spacers hold the wall sheets apart. The spacers can be discrete spherical beads or monolithic sheets of glass or ceramic webs with nodules protruding therefrom to form essentially point'' or line'' contacts with the metal wall sheets. In the case of monolithic spacers that form line'' contacts, two such spacers with the line contacts running perpendicular to each other form effectively point'' contacts at the intersections. Corrugations accommodate bending and expansion, tubular insulated pipes and conduits, and preferred applications are also included.

  9. Step tunneling enhanced asymmetry in metal-insulator-insulator-metal (MIIM) diodes for rectenna applications

    Science.gov (United States)

    Alimardani, N.; Conley, J. F.

    2013-09-01

    We combine nanolaminate bilayer insulator tunnel barriers (Al2O3/HfO2, HfO2/Al2O3, Al2O3/ZrO2) deposited via atomic layer deposition (ALD) with asymmetric work function metal electrodes to produce MIIM diodes with enhanced I-V asymmetry and non-linearity. We show that the improvements in MIIM devices are due to step tunneling rather than resonant tunneling. We also investigate conduction processes as a function of temperature in MIM devices with Nb2O5 and Ta2O5 high electron affinity insulators. For both Nb2O5 and Ta2O5 insulators, the dominant conduction process is established as Schottky emission at small biases and Frenkel-Poole emission at large biases. The energy depth of the traps that dominate Frenkel-Poole emission in each material are estimated.

  10. Simulation Study of Active Ceilings with Phase Change Material in Office Buildings for Different National Building Regulations

    DEFF Research Database (Denmark)

    Farhan, Hajan; Stefansen, Casper; Bourdakis, Eleftherios

    2018-01-01

    The aim of this study was to examine the performance of phase change material (PCM) in active ceilings for an office room under different Danish building regulations for both heating and cooling purposes. A model of a two-person office room was simulated with the only heating and cooling source...... being radiant ceiling panels containing PCM. The target was to reduce energy use for the simulation models and still meet the recommended criteria of Category II for the European Standard EN 15251:2007 namely, 23°C – 26°C (73.4°F – 78.8°F) during summer and between 20°C – 24°C (68.0°F – 73.4°F) during...... winter. The office model was simulated for a whole year and analyzed for three Danish building regulations BR10 (2010), BR15 (2015) and BR20 (2020). The results show that the indoor environment was within the desired Category II, according to EN 15251 for the whole occupancy period. The predicted...

  11. External insulation with cellular plastic materials

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt; Nielsen, Anker

    2014-01-01

    External thermal insulation composite systems (ETICS) can be used as extra insulation of existing buildings. The system can be made of cellular plastic materials or mineral wool. There is a European Technical guideline, ETAG 004, that describe the tests that shall be conducted on such systems....... This paper gives a comparison of systems with mineral wool and cellular plastic, based on experience from practice and literature. It is important to look at the details in the system and at long time stability of the properties such as thermal insulation, moisture and fire. Investigation of fire properties...

  12. The Time Bounded Glass Ceiling and Young Women Managers: Career Progress and Career Success--Evidence from the UK.

    Science.gov (United States)

    Simpson, Ruth; Altman, Yochanan

    2000-01-01

    A study of 130 male and 91 female managers found that more younger women than men were in senior roles. Younger women achieved seniority faster than women over 35. However, once younger women have broken the glass ceiling at lower levels, they encounter new barriers at higher levels. (SK)

  13. Development and preliminary experimental study on micro-stacked insulator

    International Nuclear Information System (INIS)

    Ren Chengyan; Yuan Weiqun; Zhang Dongdong; Yan Ping; Wang Jue

    2009-01-01

    High gradient insulating technology is one of the key technologies in new type dielectric wall accelerator(DWA). High gradient insulator, namely micro-stacked insulator, was developed and preliminary experimental study was done. Based on the finite element and particle simulating method, surface electric field distribution and electron movement track of micro-stacked insulator were numerated, and then the optimized design proposal was put forward. Using high temperature laminated method, we developed micro-stacked insulator samples which uses exhaustive fluorinated ethylene propylene(FEP) as dielectric layer and stainless steel as metal layer. Preliminary experiment of vacuum surface flashover in nanosecond pulse voltage was done and micro-stacked insulator exhibited favorable vacuum surface flashover performance with flashover field strength of near 180 kV/cm. (authors)

  14. Cryogenic foam insulation: Abstracted publications

    Science.gov (United States)

    Williamson, F. R.

    1977-01-01

    A group of documents were chosen and abstracted which contain information on the properties of foam materials and on the use of foams as thermal insulation at cryogenic temperatures. The properties include thermal properties, mechanical properties, and compatibility properties with oxygen and other cryogenic fluids. Uses of foams include applications as thermal insulation for spacecraft propellant tanks, and for liquefied natural gas storage tanks and pipelines.

  15. Topological Field Theory of Time-Reversal Invariant Insulators

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Xiao-Liang; Hughes, Taylor; Zhang, Shou-Cheng; /Stanford U., Phys. Dept.

    2010-03-19

    We show that the fundamental time reversal invariant (TRI) insulator exists in 4 + 1 dimensions, where the effective field theory is described by the 4 + 1 dimensional Chern-Simons theory and the topological properties of the electronic structure is classified by the second Chern number. These topological properties are the natural generalizations of the time reversal breaking (TRB) quantum Hall insulator in 2 + 1 dimensions. The TRI quantum spin Hall insulator in 2 + 1 dimensions and the topological insulator in 3 + 1 dimension can be obtained as descendants from the fundamental TRI insulator in 4 + 1 dimensions through a dimensional reduction procedure. The effective topological field theory, and the Z{sub 2} topological classification for the TRI insulators in 2+1 and 3+1 dimensions are naturally obtained from this procedure. All physically measurable topological response functions of the TRI insulators are completely described by the effective topological field theory. Our effective topological field theory predicts a number of novel and measurable phenomena, the most striking of which is the topological magneto-electric effect, where an electric field generates a magnetic field in the same direction, with an universal constant of proportionality quantized in odd multiples of the fine structure constant {alpha} = e{sup 2}/hc. Finally, we present a general classification of all topological insulators in various dimensions, and describe them in terms of a unified topological Chern-Simons field theory in phase space.

  16. An Integrated Numerical and Experimental Analysis for Enhancing the Performance of the Hidden Ceiling Fan

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2014-02-01

    Full Text Available Since the inlet and outlet of hidden ceiling fan are almost located at the same Plane; thus, an improper housing may cause inhale-return phenomenon which significantly affects its power consumption and performance. In this study, a comprehensive investigation by numerical and experimental techniques was used to predict and identify the flow pattern, airflow rate, efficiency, and noise for ceiling fans with different design parameters. The results showed that the unique inhale-return phenomenon happens for an inappropriate housing. Several key parameters, such as fan guard, housing ring, inlet-to-outlet area ratio, and blockage height, are evaluated for finding out the criterion to avoid the inhale-return flow. Consequently the study finds that fan guard changes the airflow to a wider distribution with a lower velocity. A minimum blockage distance and a maximum height of ring-plate are set at 80 mm and 30 mm, respectively. Also, it is suggested that the inlet area must be bigger than the outlet area. Moreover, all the parameters show the same trend under various rotational speeds. In conclusion, this systematic investigation not only provides the fan engineer's design ability to avoid the inhale-return phenomenon, but also the predicting capability on its aerodynamic and acoustic performances.

  17. Positron Annihilation in Insulating Materials

    International Nuclear Information System (INIS)

    Asoka-Kumar, P; Sterne, PA

    2002-01-01

    We describe positron results from a wide range of insulating materials. We have completed positron experiments on a range of zeolite-y samples, KDP crystals, alkali halides and laser damaged SiO 2 . Present theoretical understanding of positron behavior in insulators is incomplete and our combined theoretical and experimental approach is aimed at developing a predictive understanding of positrons and positronium annihilation characteristics in insulators. Results from alkali halides and alkaline-earth halides show that positrons annihilate with only the halide ions, with no apparent contribution from the alkali or alkaline-earth cations. This contradicts the results of our existing theory for metals, which predicts roughly equal annihilation contributions from cation and anion. We also present result obtained using Munich positron microprobe on laser damaged SiO 2 samples

  18. [Effects of functional interactions between nonhomologous insulators Wari and Su(Hw)].

    Science.gov (United States)

    Erokhin, M M; Georgiev, P G; Chetverina, D A

    2010-01-01

    Insulators are regulatory DNA elements restricting gene activation by enhancers. Interactions between insulators can lead to both insulation and activation of promoters by enhancers. In this work, we analyzed the effects of interaction of two Drosophila insulators, Wari and Su(Hw). The functional interaction between these insulators was found to enhance the activity of the Su(Hw) insulator only, but not of the Wari insulator. This suggests that the formation of a chromatin loop between interacting insulators is not a key factor for enhancement of insulation, which is in disagreement with the main idea of structural models. In addition, the effect of interaction between Wari and Su(Hw) depends on a distance between them and on the position in the system relative to other regulatory elements.

  19. Energy conservation through thermally insulated structures

    International Nuclear Information System (INIS)

    Abu-Dayyeh, Ayoub

    2006-01-01

    The propose of this paper is to explicate its title through investigating the different available thermal insulating materials and the various techniques of application, as practiced in Jordan, in particular, and as practiced in many parts of the world in general, which will satisfy Jordanian standards in terms of heat transmittance and thermal comfort. A brief comparison with international standards will shed some light on the stringent measures enforced in the developed world and on our striving aspirations to keep pace. The paper consists of four main parts, pseudoally divided. The first part will deal with the mechanism of heat loss and heat gain in structures during summer and winter. It will also explain the Time-lag phenomenon which is vital for providing thermal comfort inside the dwellings. The second part will evaluate the damages induced by the temperature gradients on the different elements of the structure, particularly next to exterior opening. The paper will also demonstrate the damages induced by water condensation and fungus growth on the internal surfaces of the structure and within its skeleton. A correlation between condensation and thermal insulation will be established. The third part of the paper will evaluate the different available thermal insulating materials and the application techniques which will satisfy the needs for thermal insulating and thermal comfort at the least cost possible. The criteria of an economical design shall be established. As a conclusion, the paper infers answers to the following different criteria discussed throughout the different parts of the paper. The main theme of questions can be summarized as follows: 1)How energy conservation is possible due to thermal insulation? 2)The feasibility of investing in thermal insulation? 3)Is thermal comfort and a healthy atmosphere possible inside the dwellings during all season! What are the conditions necessary to sustain them? 4)What environmental impacts can exist due to

  20. Concepts for evaluation of sound insulation of dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit; Rindel, Jens Holger

    2005-01-01

    Legal sound insulation requirements have existed more than 50 years in some countries, and single-number quantities for evaluation of sound insulation have existed nearly as long time. However, the concepts have changed considerably over time from simple arithmetic averaging of frequency bands......¬ments and classification schemes revealed significant differences of concepts. The paper summarizes the history of concepts, the disadvantages of the present chaos and the benefits of consensus concerning concepts for airborne and impact sound insulation between dwellings and airborne sound insulation of facades...... with a trend towards light-weight constructions are contradictory and challenging. This calls for exchange of data and experience, implying a need for harmonized concepts, including use of spectrum adaptation terms. The paper will provide input for future discussions in EAA TC-RBA WG4: "Sound insulation...

  1. Effect of Sweating on Insulation of Footwear.

    Science.gov (United States)

    Kuklane, Kalev; Holmér, Ingvar

    1998-01-01

    The study aimed to find out the influence of sweating on footwear insulation with a thermal foot model. Simultaneously, the influence of applied weight (35 kg), sock, and steel toe cap were studied. Water to 3 sweat glands was supplied with a pump at the rate of 10 g/hr in total. Four models of boots with steel toe caps were tested. The same models were manufactured also without steel toe. Sweating reduced footwear insulation 19-25% (30-37% in toes). During static conditions, only a minimal amount of sweat evaporated from boots. Weight affected sole insulation: Reduction depended on compressibility of sole material. The influence of steel toe varied with insulation. The method of thermal foot model appears to be a practical tool for footwear evaluation.

  2. An experimental study on thermal properties of composite insulation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyoung-Seok [Building and Urban Research Department, Korea Institute of Construction Technology, 2311 Daehwa-Dong, Ilsanseo-Gu, Goyang-Si, Gyeonggi-Do 411-712 (Korea); College of Architecture, Hanyang University, 17, Hangdang-Dong, Sungdong-Gu, Seoul 133-791 (Korea); Kang, Jae-Sik; Jeong, Young-Sun; Lee, Seung-Eon [Building and Urban Research Department, Korea Institute of Construction Technology, 2311 Daehwa-Dong, Ilsanseo-Gu, Goyang-Si, Gyeonggi-Do 411-712 (Korea); Sohn, Jang-Yeul [College of Architecture, Hanyang University, 17, Hangdang-Dong, Sungdong-Gu, Seoul 133-791 (Korea)

    2007-04-01

    In accordance with the insulation standards reinforced since 2001 and the compulsory standards on floor impact sound insulation that have been enforced since 2004, insulation materials for actual buildings have been converted to composite materials and new insulation materials have been released in the market. However, Korea is lagging behind the world in fundamental experimental studies and resources. In case of some composite insulation materials, there also have been problems of distorted performance occurring as a result of tests being conducted without having verification and evaluation on the accuracy and inaccuracy of such tests. Therefore, this study grasped the thermal properties of composite insulation materials using thermal conductivity test equipment by heat flux method, and performed quantitative evaluation on the measurement precision and uncertainty of composite materials. (author)

  3. Technical - Economic Research for Passive Buildings

    Science.gov (United States)

    Miniotaite, Ruta

    2017-10-01

    A newly constructed passive house must save 80 % of heat resources; otherwise it is not a passive house. The heating energy demand of a passive building is less than 15 kWh/m2 per year. However, a passive house is something more than just an energy-saving house. This concept involves sustainable, high-quality, valuable, healthy and durable construction. Features of a passive house: high insulation of envelope components, high-quality windows, good tightness of the building, regenerative ventilation system and elimination of thermal bridges. The Energy Performance of Buildings Directive (EPBD) 61 requires all new public buildings to become near-zero energy buildings by 2019 and will be extended to all new buildings by 2021. This concept involves sustainable, high-quality, valuable, healthy and durable construction. Foundation, walls and roofs are the most essential elements of a house. The type of foundation for a private house is selected considering many factors. The article examines technological and structural solutions for passive buildings foundation, walls and roofs. The technical-economic comparison of the main structures of a passive house revealed that it is cheaper to install an adequately designed concrete slab foundation than to build strip or pile foundation and the floor separately. Timber stud walls are the cheapest wall option for a passive house and 45-51% cheaper compared to other options. The comparison of roofs and ceilings showed that insulation of the ceiling is 25% more efficient than insulation of the roof. The comparison of the main envelope elements efficiency by multiple-criteria evaluation methods showed that it is economically feasible to install concrete slab on ground foundation, stud walls with sheet cladding and a pitched roof with insulated ceiling.

  4. Insulation systems for superconducting transmission cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1996-01-01

    the electrical insulation is placed outside both the superconducting tube and the cryostat. The superconducting tube is cooled by liquid nitrogen which is pumped through the hollow part of the tube.2) The cryogenic dielectric design, where the electrical insulation is placed inside the cryostat and thus is kept...

  5. Radiant Ceiling Panels Combined with Localized Methods for Improved Thermal Comfort of Both Patient and Medical Staff in Patient Room

    DEFF Research Database (Denmark)

    Mori, Sakura; Barova, Mariya; Bolashikov, Zhecho Dimitrov

    2012-01-01

    The objectives were to identify whether ceiling installed radiant heating panels can provide thermal comfort to the occupants in a patient room, and to determine a method for optimal thermal environment to both patient and medical staff simultaneously. The experiments were performed in a climate...... mattress were used to provide local heating for the patient. The effects of the methods were identified by comparing the manikin based equivalent temperatures. The optimal thermal comfort level for both patient and medical staff would obtained when two conventional cotton blankets were used with extra...... chamber resembling a single-bed patient room under convective air conditioning alone or combined with the ceiling installed radiant heating panels. Two thermal manikins simulated a patient lying in the bed and a doctor standing next to the patient. Conventional cotton blanket, electric blanket, electric...

  6. High-voltage polymeric insulated cables

    Energy Technology Data Exchange (ETDEWEB)

    Ross, A

    1987-01-01

    Reviews developments in high-voltage (here defined as 25 kV, 66 kV and 132 kV) polymeric insulated cables in the UK over the period 1979-1986, with particular reference to the experience of the Eastern Electricity Board. Outlines the background to the adoption of XPLE-insulated solid cable, and the design, testing, terminations, jointing and costs of 25 kV, 66 kV and 132 kV cables.

  7. To Climb or Not to Climb: The Probing of Self-Imposed Barriers that Delay or Deny Career Aspirations to be an Administrator in a Public School System

    Science.gov (United States)

    McGee, Janet M.

    2010-01-01

    Throughout history, women have faced numerous career barriers. Although significant progress has made it possible to break through the "glass ceiling," there remains a disproportionate percentage of women at the higher educational administrative positions, specifically the superintendent and high school principal roles. This study will…

  8. Artificial heart system thermal insulation component development

    International Nuclear Information System (INIS)

    Svedberg, R.C.; Buckman, R.W. Jr.

    1975-01-01

    A concentric cup vacuum multifoil insulation system has been selected by virtue of its size, weight, and thermal performance to insulate the hot radioisotope portion of the thermal converter of an artificial implantable heart system. A factor of 2 improvement in thermal performance, based on the heat loss per number of foil layers (minimum system weight and volume) has been realized over conventional spiral wrapped multifoil vacuum insulation. This improvement is the result of the concentric cup construction to maintain a uniform interfoil spacing and the elimination of corner heat losses. Based on external insulation system dimensions (surface area in contact with host body), heat losses of 0.019 W/ cm 2 at 1140 0 K (1600 0 F) and 0.006 W/cm 2 at 920 0 K (1200 0 F) have been achieved. Factors which influence thermal performance of the nickel foil concentric cup insulation system include the number of cups, configuration and method of application of zirconia (ZrO 2 ) spacer material, system pressure, emittance of the cups, and operating temperature

  9. Heat insulating plates

    Energy Technology Data Exchange (ETDEWEB)

    Allan, J.A.F.

    1976-10-28

    Micro-porous insulation plates are dealt with, for example, how they are used in the insulation of heat storage devices. Since one side of such plates is exposed to a temperature of over 700/sup 0/C, a shrinkage of the glass texture of the covering can occur, which can exceed the shrinkage of the inner micro-porous material, so that cracks and splits in the high temperature side of the covering can come about. The task of the invention is to design the plate in such a way as to prevent this from happening. For this purpose the plate is provided, according to invention specifications, with flutes, waves, ribs, waffle or grid patterns and the covering is set into the recesses originating from this.

  10. Topological insulators and superconductors from string theory

    International Nuclear Information System (INIS)

    Ryu, Shinsei; Takayanagi, Tadashi

    2010-01-01

    Topological insulators and superconductors in different spatial dimensions and with different discrete symmetries have been fully classified recently, revealing a periodic structure for the pattern of possible types of topological insulators and superconductors, both in terms of spatial dimensions and in terms of symmetry classes. It was proposed that K theory is behind the periodicity. On the other hand, D-branes, a solitonic object in string theory, are also known to be classified by K theory. In this paper, by inspecting low-energy effective field theories realized by two parallel D-branes, we establish a one-to-one correspondence between the K-theory classification of topological insulators/superconductors and D-brane charges. In addition, the string theory realization of topological insulators and superconductors comes naturally with gauge interactions, and the Wess-Zumino term of the D-branes gives rise to a gauge field theory of topological nature, such as ones with the Chern-Simons term or the θ term in various dimensions. This sheds light on topological insulators and superconductors beyond noninteracting systems, and the underlying topological field theory description thereof. In particular, our string theory realization includes the honeycomb lattice Kitaev model in two spatial dimensions, and its higher-dimensional extensions. Increasing the number of D-branes naturally leads to a realization of topological insulators and superconductors in terms of holography (AdS/CFT).

  11. Silicon on insulator self-aligned transistors

    Science.gov (United States)

    McCarthy, Anthony M.

    2003-11-18

    A method for fabricating thin-film single-crystal silicon-on-insulator (SOI) self-aligned transistors. Standard processing of silicon substrates is used to fabricate the transistors. Physical spaces, between the source and gate, and the drain and gate, introduced by etching the polysilicon gate material, are used to provide connecting implants (bridges) which allow the transistor to perform normally. After completion of the silicon substrate processing, the silicon wafer is bonded to an insulator (glass) substrate, and the silicon substrate is removed leaving the transistors on the insulator (glass) substrate. Transistors fabricated by this method may be utilized, for example, in flat panel displays, etc.

  12. Emerging Trends in Topological Insulators and Topological ...

    Indian Academy of Sciences (India)

    /fulltext/reso/022/08/0787-0800. Keywords. Superconductor, quantum Hall effect, topological insulator, Majorana fermions. Abstract. Topological insulators are new class of materials which arecharacterized by a bulk band gap like ordinary ...

  13. Air Distribution in a Room with Ceiling-Mounted Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Heby, Thomas; Moeller-Jensen, Bertil

    2006-01-01

    . The characteristics of the air distribution systems are addressed by analysing the acceptable conditions for the supply flow rate and the temperature difference for the different systems. The paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity...... with swirling flow generates a flow pattern in the room which is rather uninfluenced by the thermal load. The flow is highly mixed above the occupied zone and the air movement penetrates the occupied zone close to the walls. All systems are tested in the same room with the same heat load consisting of two...... manikins, each sitting at a desk, two pc's and two desk lamps producing a total heat load of 480 W. The design of the air distribution system is in all five cases based on flow elements from the diffuser, a maximum velocity assumption and a critical vertical temperature gradient in the room...

  14. The Development and Application of Simulative Insulation Resistance Tester

    Science.gov (United States)

    Jia, Yan; Chai, Ziqi; Wang, Bo; Ma, Hao

    2018-02-01

    The insulation state determines the performance and insulation life of electrical equipment, so it has to be judged in a timely and accurate manner. Insulation resistance test, as the simplest and most basic test of high voltage electric tests, can measure the insulation resistance and absorption ratio which are effective criterion of part or whole damp or dirty, breakdown, severe overheating aging and other insulation defects. It means that the electrical test personnel need to be familiar with the principle of insulation resistance test, and able to operate the insulation resistance tester correctly. At present, like the insulation resistance test, most of electrical tests are trained by physical devices with the real high voltage. Although this allows the students to truly experience the test process and notes on security, it also has certain limitations in terms of safety and test efficiency, especially for a large number of new staves needing induction training every year. This paper presents a new kind of electrical test training system based on the simulative device of dielectric loss measurement and simulative electrical testing devices. It can not only overcome the defects of current training methods, but also provide other advantages in economical efficiency and scalability. That makes it possible for the system to be allied in widespread.

  15. Facility for endurance tests of thermal insulations

    International Nuclear Information System (INIS)

    Mauersberger, R.

    1984-01-01

    In the following report the design and construction of an experimental facility for endurance tests of thermal insulations is presented. It's name in abbreviation is 'ADI' standing for the German words A nlage zum Dauertest von Isolierungen . This test facility was build by HRB in order to investigate the performance of thermal insulation systems of hot gas ducts for the process heat-reactor-project. The tests are intended to simulate the conditions of reactor operation. They include short-time experiments for selection of insulation-concepts and in a second step long-time experiments as performance tests. During these tests are measured the effective heat conductivity the local heat losses the temperature profiles of the insulation, of the fixing elements and along the wall of the duct. The design-data required to perform all these tasks are shown in the first picture: The gas-atmosphere must be Helium in tests like in reactor with regard to the special thermal and hydraulic properties of Helium and to the influence of Helium on mechanic friction and wear. The hot gas temperature in the PNP-reactor will be 950 deg. C and should be equal in the experiments. The temperature on the cold side of the insulation has to be adjustable from 50 deg. C up to 300 deg. C. The Helium pressure in the hot gas ducts of a HTR-plant is about 42 bar. The ADI was laid out for 70 bar to cover the hole range of interest. A Helium mass flow has to stream through the insulated test duct in order to realize equal temperatures on the hot side of the insulation. A flow rate of 4,5 kg/s is sufficient for this requirement. The axial pressure gradient along the insulation must be the same as in the reactor, because this has an essential influence on the heat losses. This pressure gradient is about 40 Pa/m

  16. Fermi surfaces in Kondo insulators

    Science.gov (United States)

    Liu, Hsu; Hartstein, Máté; Wallace, Gregory J.; Davies, Alexander J.; Ciomaga Hatnean, Monica; Johannes, Michelle D.; Shitsevalova, Natalya; Balakrishnan, Geetha; Sebastian, Suchitra E.

    2018-04-01

    We report magnetic quantum oscillations measured using torque magnetisation in the Kondo insulator YbB12 and discuss the potential origin of the underlying Fermi surface. Observed quantum oscillations as well as complementary quantities such as a finite linear specific heat capacity in YbB12 exhibit similarities with the Kondo insulator SmB6, yet also crucial differences. Small heavy Fermi sections are observed in YbB12 with similarities to the neighbouring heavy fermion semimetallic Fermi surface, in contrast to large light Fermi surface sections in SmB6 which are more similar to the conduction electron Fermi surface. A rich spectrum of theoretical models is suggested to explain the origin across different Kondo insulating families of a bulk Fermi surface potentially from novel itinerant quasiparticles that couple to magnetic fields, yet do not couple to weak DC electric fields.

  17. Process for manufacture of Te microwire in glass insulation

    International Nuclear Information System (INIS)

    Bodiul, Pavel; Nicolaeva, Alibina; Konopko, Leonid; Bondarciuc, Nicolae

    2010-01-01

    The invention relates to the manufacturing of microwires in glass insulation and can be used in electronics and in the manufacturing of thermoelectrodes for thermoelectric sensors. The process for manufacture of Te microwire in glass insulation consists in softening the Te sample and its pulling in glass insulation. Near the microwire pulling zone through the furnace is maintained a temperature of 430-440 degrees Celsius, which causes the solidification firstly of Te microwire, and then of glass insulation. The result of the invention is to obtain Te microwires in glass insulation of high quality with a diameter of 50-100 μm and a length of 3-15 cm.

  18. Insulation coordination workstation for AC and DC substations

    International Nuclear Information System (INIS)

    Booth, R.R.; Hileman, A.R.

    1990-01-01

    The Insulation Coordination Workstation was designed to aid the substation design engineer in the insulation coordination process. The workstation utilizes state of the art computer technology to present a set of tools necessary for substation insulation coordination, and to support the decision making process for all aspects of insulation coordination. The workstation is currently being developed for personal computers supporting OS/2 Presentation Manager. Modern Computer-Aided Software Engineering (CASE) technology was utilized to create an easily expandable framework which currently consists of four modules, each accessing a central application database. The heart of the workstation is a library of user-friendly application programs for the calculation of important voltage stresses used for the evaluation of insulation coordination. The Oneline Diagram is a graphic interface for data entry into the EPRI distributed EMTP program, which allows the creation of complex systems on the CRT screen using simple mouse clicks and keyboard entries. Station shielding is graphically represented in the Geographic Viewport using a three-dimensional substation model, and the interactive plotting package allows plotting of EPRI EMTP output results on the CRT screen, printer, or pen plotter. The Insulation Coordination Workstation was designed by Advanced Systems Technology (AST), a division of ABB Power Systems, Inc., and sponsored by the Electric Power Research Institute under RP 2323-5, AC/DC Insulation Coordination Workstation

  19. Air-Filled Nanopore Based High-Performance Thermal Insulation Materials

    OpenAIRE

    Gangåssæter, Haakon Fossen; Jelle, Bjørn Petter; Alex Mofid, Sohrab; Gao, Tao

    2017-01-01

    State-of-the-art thermal insulation solutions like vacuum insulation panels (VIP) and aerogels have low thermal conductivity, but their drawbacks may make them unable to be the thermal insulation solutions that will revolutionize the building industry regarding energy-efficient building envelopes. Nevertheless, learning from these materials may be crucial to make new and novel high-performance thermal insulation products. This study presents a review on the state-of-the-art air-filled thermal...

  20. 5th Duisburg thermal insulation days. Fuenfte Duisburger Waermedaemm-Tage

    Energy Technology Data Exchange (ETDEWEB)

    Agst, J. (ed.)

    1989-01-01

    This volume contains 18 specialist lectures mainly about the problems of thermal insulation in industrial furnaces and facility engineering. Among the subjects are: formed parts, monolithic lining materials and fillers of vermiculite; pyro-block-modular systems for furnaces (of the company DYKO-Morgan Fasertechnik); microporous insulating materials (KAOWOOL); properties of lightweight refractory bricks; thermal insulation in induction furnaces; vacuum moulded parts in electric furnace engineering; high temperature insulating materials with ceramic fibres; microtherm insulating materials. (MM).

  1. Experimental investigation of cooling performance of a novel HVAC system combining natural ventilation with diffuse ceiling inlet and TABS

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2015-01-01

    Highlights •An experimental investigation of cooling performance of a combined HVAC system is carried out. •Cooling performance of TABS with and without the influence of diffuse ceiling is analyzed. •Radiant and convective heat transfer coefficients of TABS cooling are studied. •Cooling components...

  2. Superconductivity and ferromagnetism in topological insulators

    Science.gov (United States)

    Zhang, Duming

    Topological insulators, a new state of matter discovered recently, have attracted great interest due to their novel properties. They are insulating inside the bulk, but conducting at the surface or edges. This peculiar behavior is characterized by an insulating bulk energy gap and gapless surface or edge states, which originate from strong spin-orbit coupling and time-reversal symmetry. The spin and momentum locked surface states not only provide a model system to study fundamental physics, but can also lead to applications in spintronics and dissipationless electronics. While topological insulators are interesting by themselves, more exotic behaviors are predicted when an energy gap is induced at the surface. This dissertation explores two types of surface state gap in topological insulators, a superconducting gap induced by proximity effect and a magnetic gap induced by chemical doping. The first three chapters provide introductory theory and experimental details of my research. Chapter 1 provides a brief introduction to the theoretical background of topological insulators. Chapter 2 is dedicated to material synthesis principles and techniques. I will focus on two major synthesis methods: molecular beam epitaxy for the growth of Bi2Se3 thin films and chemical vapor deposition for the growth of Bi2Se3 nanoribbons and nanowires. Material characterization is discussed in Chapter 3. I will describe structural, morphological, magnetic, electrical, and electronic characterization techniques used to study topological insulators. Chapter 4 discusses the experiments on proximity-induced superconductivity in topological insulator (Bi2Se3) nanoribbons. This work is motivated by the search for the elusive Majorana fermions, which act as their own antiparticles. They were proposed by Ettore Majorara in 1937, but have remained undiscovered. Recently, Majorana's concept has been revived in condensed matter physics: a condensed matter analog of Majorana fermions is predicted to

  3. Thermal-performance study of liquid metal fast breeder reactor insulation

    International Nuclear Information System (INIS)

    Shiu, K.K.

    1980-09-01

    Three types of metallic thermal insulation were investigated analytically and experimentally: multilayer reflective plates, multilayer honeycomb composite, and multilayer screens. Each type was subjected to evacuated and nonevacuated conditions, where thermal measurements were made to determine thermal-physical characteristics. A variation of the separation distance between adjacent reflective plates of multilayer reflective plates and multilayer screen insulation was also experimentally studied to reveal its significance. One configuration of the multilayer screen insulation was further selected to be examined in sodium and sodium oxide environments. The emissivity of Type 304 stainless steel used in comprising the insulation was measured by employing infrared technology. A comprehensive model was developed to describe the different proposed types of thermal insulation. Various modes of heat transfer inherent in each type of insulation were addressed and their relative importance compared. Provision was also made in the model to allow accurate simulation of possible sodium and sodium oxide contamination of the insulation. The thermal-radiation contribution to heat transfer in the temperature range of interest for LMFBR's was found to be moderate, and the suppression of natural convection within the insulation was vital in preserving its insulating properties. Experimental data were compared with the model and other published results. Moreover, the three proposed test samples were assessed and compared under various conditions as viable LMFBR thermal insulations

  4. Advances in Thermal Insulation. Vacuum Insulation Panels and Thermal Efficiency to Reduce Energy Usage in Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thorsell, Thomas

    2012-07-01

    We are coming to realize that there is an urgent need to reduce energy usage in buildings and it has to be done in a sustainable way. This thesis focuses on the performance of the building envelope; more precisely thermal performance of walls and super insulation material in the form of vacuum insulation. However, the building envelope is just one part of the whole building system, and super insulators have one major flaw: they are easily adversely affected by other problems in the built environment. Vacuum Insulation Panels are one fresh addition to the arsenal of insulation materials available to the building industry. They are composite material with a core and an enclosure which, as a composite, can reach thermal conductivities as low as 0.004 W/(mK). However, the exceptional performance relies on the barrier material preventing gas permeation, maintaining a near vacuum into the core and a minimized thermal bridge effect from the wrapping of barrier material round the edge of a panel. A serpentine edge is proposed to decrease the heat loss at the edge. Modeling and testing shows a reduction of 60 % if a reasonable serpentine edge is used. A diffusion model of permeation through multilayered barrier films with metallization coatings was developed to predict ultimate service life. The model combines numerical calculations with analytical field theory allowing for more precise determination than current models. The results using the proposed model indicate that it is possible to manufacture panels with lifetimes exceeding 50 years with existing manufacturing. Switching from the component scale to the building scale; an approach of integrated testing and modeling is proposed. Four wall types have been tested in a large range of environments with the aim to assess the hydrothermal nature and significance of thermal bridges and air leakages. The test procedure was also examined as a means for a more representative performance indicator than R-value (in USA). The

  5. Thermal insulation product for insulation, especially in nuclear power engineering, and method of its production

    International Nuclear Information System (INIS)

    Veselovsky, P.; Zink, S.; Balacek, P.; Mares, I.

    1989-01-01

    The insulation consists of a sewn fabric cover made of inorganic fibers, in which the fiber filling is reinforced mechanically by dense point interweaving. The inorganic fibers, 1 to 5 μm in diameter, consist of min. 97 wt.% mixture of aluminium and silicon oxides in the vitreous state. The fibers making up the cover consist of min. 95% silicon, aluminium, calcium, magnesium and boron oxides in the vitreous state; the rest can consist of alloy steel fibres. The bulk density of the insulation is 70 to 150 kg/m 3 . The product is highly resistant to temperature and to the action of chemicals, water, and acid and alkaline deactivation solutions. Its manufacture is fast and undemanding. It is designed for thermal insulation of pipes, tanks and valves in nuclear power plants. (M.D.). 2 figs

  6. Maximizing the lightshelf performance by interaction between lightshelf geometries and a curved ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Freewan, Ahmed A. [Jordan University of Science and Technology, Irbid 22110 (Jordan)

    2010-08-15

    The interaction between different lightshelf geometries combined with a curved ceiling was investigated using radiance to maximize the daylight performance of a lightshelf. Two main performance parameters were investigated; illuminance level and distribution uniformity in a large space located in a sub-tropical climate region like Jordan. It was found that a curved lightshelf could improve the daylight level by 10% compared to a horizontal lightshelf. A curved lightshelf help to bounce more daylight deep into a space thus improve the illuminance level and uniformity level. The best lightshelf shapes found are curved and chamfered lightshelves compared to horizontal lightshelves. (author)

  7. The Wick-Concept for Thermal Insulation of Cold Piping

    DEFF Research Database (Denmark)

    Koverdynsky, Vit; Korsgaard, Vagn; Rode, Carsten

    2006-01-01

    the wick-concept in either of two variations: the self-drying or the self-sealing system. Experiments have been carried out using different variations of the two systems to investigate the conditions for exploiting the drying capabilities of the systems, and the results are presented. The results show......The wick-concept for thermal insulation of cold piping is based on capillary suction of a fiber fabric to remove excess water from the pipe surface by transporting it to the outer surface of the insulation. From the surface of the insulation jacket, the water will evaporate to the ambient air....... This will prevent long-term accumulation of moisture in the insulation material. The wick keeps the hydrophobic insulation dry, allowing it to maintain its thermal performance. The liquid moisture is kept only in the wick fabric. This article presents the principle of operation of cold pipe insulation using...

  8. Topological insulators and superconductors: tenfold way and dimensional hierarchy

    International Nuclear Information System (INIS)

    Ryu, Shinsei; Schnyder, Andreas P; Furusaki, Akira; Ludwig, Andreas W W

    2010-01-01

    It has recently been shown that in every spatial dimension there exist precisely five distinct classes of topological insulators or superconductors. Within a given class, the different topological sectors can be distinguished, depending on the case, by a Z or a Z 2 topological invariant. This is an exhaustive classification. Here we construct representatives of topological insulators and superconductors for all five classes and in arbitrary spatial dimension d, in terms of Dirac Hamiltonians. Using these representatives we demonstrate how topological insulators (superconductors) in different dimensions and different classes can be related via 'dimensional reduction' by compactifying one or more spatial dimensions (in 'Kaluza-Klein'-like fashion). For Z-topological insulators (superconductors) this proceeds by descending by one dimension at a time into a different class. The Z 2 -topological insulators (superconductors), on the other hand, are shown to be lower-dimensional descendants of parent Z-topological insulators in the same class, from which they inherit their topological properties. The eightfold periodicity in dimension d that exists for topological insulators (superconductors) with Hamiltonians satisfying at least one reality condition (arising from time-reversal or charge-conjugation/particle-hole symmetries) is a reflection of the eightfold periodicity of the spinor representations of the orthogonal groups SO(N) (a form of Bott periodicity). Furthermore, we derive for general spatial dimensions a relation between the topological invariant that characterizes topological insulators and superconductors with chiral symmetry (i.e., the winding number) and the Chern-Simons invariant. For lower-dimensional cases, this formula relates the winding number to the electric polarization (d=1 spatial dimensions) or to the magnetoelectric polarizability (d=3 spatial dimensions). Finally, we also discuss topological field theories describing the spacetime theory of

  9. Electrical insulation for large multiaxis superconducting magnets

    International Nuclear Information System (INIS)

    Harvey, A.R.; Rinde, J.A.

    1975-01-01

    The selection of interturn and interlayer insulation for superconducting magnets is discussed. The magnet problems of the Baseball II device are described. Manufacture of the insulation and radiation damage are mentioned. A planned experimental program is outlined

  10. Material selection and embodied energy

    CSIR Research Space (South Africa)

    Ampofo-Anti, N

    2010-11-01

    Full Text Available mix concrete apron Non reinforced, ready mix concrete strip foundation Non reinforced, ready mix ground floor slab Concrete block Modular, hollow concrete block Solid concrete block Finishes Floor screed Insulated ceiling panel Perlite... Predicting the embodied energy contribution of a single material is however not as easy as green building practices assume. As illustrated by the example in Box 1, the choice of a material implies the choice of integral constituents such as insulation...

  11. Analysis and comparison of magnetic sheet insulation tests

    Science.gov (United States)

    Marion-Péra, M. C.; Kedous-Lebouc, A.; Cornut, B.; Brissonneau, P.

    1994-05-01

    Magnetic circuits of electrical machines are divided into coated sheets in order to limit eddy currents. The surface insulation resistance of magnetic sheets is difficult to evaluate because it depends on parameters like pressure and covers a wide range of values. Two methods of measuring insulation resistance are analyzed: the standardized 'Franklin device' and a tester developed by British Steel Electrical. Their main drawback is poor local repeatability. The Franklin method allows better quality control of industrial process because it measures only one insulating layer at a time. It also gives more accurate images of the distribution of possible defects. Nevertheless, both methods lead to similar classifications of insulation efficiency.

  12. Insulating Foams Save Money, Increase Safety

    Science.gov (United States)

    2009-01-01

    Scientists at Langley Research Center created polyimide foam insulation for reusable cryogenic propellant tanks on the space shuttle. Meanwhile, a small Hialeah, Florida-based business, PolyuMAC Inc., was looking for advanced foams to use in the customized manufacturing of acoustical and thermal insulation. The company contacted NASA, licensed the material, and then the original inventors worked with the company's engineers to make a new material that was better for both parties. The new version, a high performance, flame retardant, flexible polyimide foam, is used for insulating NASA cryogenic propellant tanks and shows promise for use on watercraft, aircraft, spacecraft, electronics and electrical products, automobiles and automotive products, recreation equipment, and building and construction materials.

  13. Crosslinking of wire and cable insulation using electron accelerators

    International Nuclear Information System (INIS)

    Feng Yongxiang; Ma Zueteh

    1992-01-01

    Radiation crosslinking of wire and cable insulation is a well-established technology that is widely used in industry. The advantages of radiation crosslinking over chemical crosslinking have helped maintain its steady growth. Since successful utilization of electron beam processing relies on the formulation of compounds used in insulation, the radiation crosslinking of various polymers is reviewed. The handling technology for crosslinking wire and cable insulation and the throughput capacity of electron beam processors are also discussed. More than 30% of the industrial electron accelerators in the world are used for the radiation crosslinking of wire and cable insulation. Prospects of increased use of electron accelerators for crosslinking of wire and cable insulation are very good. (orig.)

  14. Improved Thermal-Insulation Systems for Low Temperatures

    Science.gov (United States)

    Fesmire, James E.; Augustynowicz, Stanislaw D.

    2003-01-01

    Improved thermal-insulation materials and structures and the techniques for manufacturing them are undergoing development for use in low-temperature applications. Examples of low-temperature equipment for which these thermal insulation systems could provide improved energy efficiency include storage tanks for cryogens, superconducting electric-power-transmission equipment, containers for transport of food and other perishable commodities, and cold boxes for low-temperature industrial processes. These systems could also be used to insulate piping used to transfer cryogens and other fluids, such as liquefied natural gas, refrigerants, chilled water, crude oil, or low-pressure steam. The present thermal-insulation systems are layer composites based partly on the older class of thermal-insulation systems denoted generally as multilayer insulation (MLI). A typical MLI structure includes an evacuated jacket, within which many layers of radiation shields are stacked or wrapped close together. Low-thermal-conductivity spacers are typically placed between the reflection layers to keep them from touching. MLI can work very well when a high vacuum level (less than 10(exp-4) torr) is maintained and utmost care is taken during installation, but its thermal performance deteriorates sharply as the pressure in the evacuated space rises into the soft vacuum range [pressures greater than 0.1 torr (greater than 13 Pa)]. In addition, the thermal performance of MLI is extremely sensitive to mechanical compression and edge effects and can easily decrease from one to two orders of magnitude from its ideal value even when the MLI is kept under high vacuum condition. The present thermal-insulation systems are designed to perform well under soft vacuum level, in particular the range of 1 to 10 torr. They are also designed with larger interlayer spacings to reduce vulnerability to compression (and consequent heat leak) caused by installation and use. The superiority of these systems is the

  15. Simulation of Contamination Deposition on Typical Shed Porcelain Insulators

    Directory of Open Access Journals (Sweden)

    Yukun Lv

    2017-07-01

    Full Text Available The contamination deposition characteristics of insulators can be used in the development of antifouling work. Using COMSOL software, numerical simulations on the pollution-deposited performance of a porcelain three-umbrella insulator and porcelain bell jar insulator in a wind tunnel were conducted, and the simulated results were compared with the tested results. The comparison shows that the deposit amount is consistent with the order of magnitude and presents a similar tendency with Direct Current (DC voltage variation; then the rationality of the simulation is verified. Based on these results, simulations of the natural contamination deposition on porcelain insulators and the distribution of pollution along the umbrella skirt were performed. The results indicates that, under a same wind speed, contamination of the porcelain three-umbrella insulator and porcelain bell jar insulator under DC voltage was positively correlated with the particle size. With the same particle size, the proportion of the deposit amount under DC voltage (NSDDDC to the deposit amount under AC voltage (NSDDAC of both insulators decreases with the increase in wind speed. However, the ratio increases as particle size increase. At a small wind speed, the deposit amount along the umbrella skirt of the two insulators displays a U-shaped distribution under DC voltage while there is little difference in the contamination amount of each skirt under Alternating Current (AC voltage.

  16. Insulated Wire Fed Floating Monopole Antenna for Coastal Monitoring

    Directory of Open Access Journals (Sweden)

    Z. M. Loni

    2018-04-01

    Full Text Available A thin, flexible, insulated wire submerged in seawater forms a coaxial cable which has attenuation at ultra-high frequency (UHF dependent on the operating frequency, the diameter of the insulating material and the diameter of the inner conductor. An extension of the insulated wire above the surface through a spherical float forms a monopole antenna. Attenuation through the wire depends on the conductivity and temperature of seawater. This paper reports the effect of electromagnetic (EM wave propagation at 433 MHz through insulated wires with different radii of the insulating material and inner conductor. The attenuation was calculated and measured in the range of 32-47 dB/m. The propagation from the monopole antenna to a fixed shore based receiver was measured to be approximately equal to 1 dB/m. The propagation measurements were compared with a shielded coaxial cable. Results show that the propagation range depends on the ratio of the insulation radius to conductor radius for insulated wire, however, a shielded coaxial cable showed no significant attenuation. The technique has applications in coastal wireless sensor networks where the water depth changes continually due to tide and wave motion.

  17. Calculation of high-temperature insulation parameters and heat transfer behaviors of multilayer insulation by inverse problems method

    Directory of Open Access Journals (Sweden)

    Huang Can

    2014-08-01

    Full Text Available In the present paper, a numerical model combining radiation and conduction for porous materials is developed based on the finite volume method. The model can be used to investigate high-temperature thermal insulations which are widely used in metallic thermal protection systems on reusable launch vehicles and high-temperature fuel cells. The effective thermal conductivities (ECTs which are measured experimentally can hardly be used separately to analyze the heat transfer behaviors of conduction and radiation for high-temperature insulation. By fitting the effective thermal conductivities with experimental data, the equivalent radiation transmittance, absorptivity and reflectivity, as well as a linear function to describe the relationship between temperature and conductivity can be estimated by an inverse problems method. The deviation between the calculated and measured effective thermal conductivities is less than 4%. Using the material parameters so obtained for conduction and radiation, the heat transfer process in multilayer thermal insulation (MTI is calculated and the deviation between the calculated and the measured transient temperatures at a certain depth in the multilayer thermal insulation is less than 6.5%.

  18. Participação Popular em Saúde: Um Estudo Sobre o Conselho Regional de Saúde de Ceilândia, Distrito Federal.

    Directory of Open Access Journals (Sweden)

    Andrecinda Rocha PINA

    2013-04-01

    Full Text Available A questão da participação popular para o exercício do controle social do Sistema Único de Saúde é especialmente importante para o debate da política de saúde no Brasil e, conforme estabelecido na Lei 8142 de 1990, essa participação deve ser realizada por meio dos conselhos e conferências de saúde. O presente artigo estuda a participação popular em saúde no Conselho Regional de Saúde de Ceilândia, Distrito Federal, problematizando em torno do exercício do controle social exercido pelos conselheiros do respectivo colegiado. Esta pesquisa teve por objetivo geral entender como se dá a Participação Social no Conselho Regional de Saúde de Ceilândia na gestão 2010-2011, buscando especificamente entender sua dinâmica de funcionamento. Partindo de uma abordagem metodológica qualiquantitativa, utilizamos como procedimento a análise documental, com levantamento de dados relativos à dinâmica de suas reuniões. Depreende-se do estudo realizado a participação expressiva dos segmentos integrantes. A grande maioria dos assuntos pautados foi proposta, especialmente, pelo segmento gestor. Entretanto, os itens em discussão revelam que os interesses dos usuários e trabalhadores permeavam com mais frequência os debates. Por fim, conclui-se que, em um contexto geral, o Conselho Regional de Saúde de Ceilândia é um fórum político legítimo e atuante, com atuação decisiva nas deliberações das ações e serviços de saúde a nível local. ABSTRACT The issue of popular participation in the exercise of social control Health System is especially important for the health policy debate in Brazil and, as stated in the Law 8142/1990, this participation must be done through the advice and health conferences. This paper studies popular participation in health in the Regional Health Ceilândia, Distrito Federal, questioning around the exercise of social control exercised by the directors of the respective collegiate. This research aimed

  19. Insulator layer formation in MgB2 SIS junctions

    International Nuclear Information System (INIS)

    Shimakage, H.; Tsujimoto, K.; Wang, Z.; Tonouchi, M.

    2005-01-01

    The dependence of current-voltage characteristics on thin film deposition conditions was investigated using MgB 2 /AlN/NbN SIS junctions. By increasing the substrate temperature in AlN insulator deposition, the current density decreased and the normal resistance increased. The results indicated that an additional insulator layer between the MgB 2 and AlN formed, either before or during the AlN deposition. The thickness of the additional insulator layer was increased with an increase in the AlN deposition temperature. From the dependence of current density on the thickness of AlN in low temperature depositions, the thickness of the additional insulator layer was estimated to be 1-1.5 nm when the AlN insulator was deposited from 0.14 to 0.7 nm. Moreover, with the current density of MgB 2 /AlN/MgB 2 SIS junctions, further insulator layer formation was confirmed

  20. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...... manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance...

  1. Spin-polarized tunneling through a ferromagnetic insulator

    NARCIS (Netherlands)

    Kok, M.; Kok, M.; Beukers, J.N.; Brinkman, Alexander

    2009-01-01

    The polarization of the tunnel conductance of spin-selective ferromagnetic insulators is modeled, providing a generalized concept of polarization including both the effects of electrode and barrier polarization. The polarization model is extended to take additional non-spin-polarizing insulating

  2. 77 FR 29322 - Updating State Residential Building Energy Efficiency Codes

    Science.gov (United States)

    2012-05-17

    ... Glass Company North America (AGC). However, DOE notes that PNA/AGC's comment was received late. Although... following. Steel-framed wall insulation Air barrier location Changes whose effect is unclear: Fenestration... code's primary regulation of a home's envelope thermal resistance, or the resistance of the ceilings...

  3. Thermal insulation. Non-utilized energy need not be generated. Four rules for a successful thermal insulation by means of building insulation; Waermedaemmung. Energie, die nicht gebraucht wird, muss man nicht erzeugen. Vier Regeln fuer erfolgreichen Waermeschutz durch Gebaeudedaemmung

    Energy Technology Data Exchange (ETDEWEB)

    Patschke, Markus [3E-Consult, Nordkirchen (Germany); Drewer, Arnold [IpeG-Institut, Paderborn (Germany)

    2011-07-15

    The heat supply of buildings causes nearly one third of the energy consumption of an industrialized country. In 2006, the climate-adjusted heat consumption of private households in Germany amounted nearly 600 billion kWh. This consumption caused more than 167 million tons of CO{sub 2}. Heat insulation measures in buildings are required for all heat-transferring enveloping surface. Under this aspect, the contribution under consideration reports on four fundamental rules for a cost-efficient building insulation: (a) Only heated rooms should be insulated thermally; (b) Location and thermal insulation of cavities; (c) Selection of a suitable insulating material; (d) Consideration of an economic sustainability.

  4. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  5. Further considerations for damping in heavily insulated pipe systems

    International Nuclear Information System (INIS)

    Anderson, M.J.; Lindquist, M.R.; Severud, L.K.

    1985-01-01

    Over the past several years a body of test data has been accumulated which demonstrates that damping in small diameter heavily insulated pipe systems is much larger than presently recommended by Regulatory Guide 1.61. This data is generally based on pipe systems using a stand-off insulation design with a heater annulus. Additional tests have how been completed on similar pipe systems using a strap-on insulation design without the heater annulus. Results indicate some reduction in damping over the stand-off designs. Test data has also been obtained on a larger sixteen-inch diameter heavily insulated pipe system. Results of these two additional test series are presented. Revised damping values for seismic design of heavily insulated pipe systems are then recommended

  6. Further considerations for damping in heavily insulated pipe systems

    International Nuclear Information System (INIS)

    Anderson, M.J.; Lindquist, M.R.; Severud, L.K.

    1985-01-01

    Over the past several years a body of test data has been accumulated which demonstrates that damping in small diameter heavily insulated pipe systems is much larger than presently recommended by Regulatory Code 1.61. This data is generally based on pipe systems using a stand-off insulation design with a heater annulus. Additional tests have now been completed on similar pipe systems using a strap-on insulation design without the heater annulus. Results indicate some reduction in damping over the stand-off designs. Test data has also been obtained on a larger sixteen-inch diameter heavily insulated pipe system. Results of these two additional test series are presented. Revised damping values for seismic design for heavily insulated pipe systems are then recommended

  7. Insulator-insulator and insulator-conductor transitions in the phase diagram of aluminium trichloride

    Directory of Open Access Journals (Sweden)

    Romina Ruberto

    2009-01-01

    Full Text Available We report a classical computer-simulation study of the phase diagram of AlCl3 in the pressure-temperature (p, T plane, showing (i that melting from a layered crystal structure occurs into a molecular liquid at low (p, T and into a dissociated ionic liquid at high (p, T, and (ii that a broad transition from a molecular insulator to an ionic conductor takes place in the liquid state.

  8. Integrated sound absorption in thermally activated concrete ceilings - acoustic and thermal effectiveness of sound-absorber strips spaced at intervals; Integrierte Schallabsorption in thermisch aktivierten Betondecken - akustische und thermische Wirksamkeit periodischer Schallabsorberstreifen

    Energy Technology Data Exchange (ETDEWEB)

    Drotleff, Horst; Wack, Roman; Leistner, Philip; Holm, Andreas; Ziegler, Matthias; Sedlbauer, Klaus [Fraunhofer-Institut fuer Bauphysik IBP, Stuttgart (Germany)

    2011-10-15

    From the perspectives of energy as well as indoor climate, thermally activated concrete ceilings make sense. Used in office buildings, however, their drawback becomes apparent: they are acoustically reflective. The conventional approaches use sound-absorbing suspended sails and absorber baffles or heat-conducting sound absorbers embedded in large areas of the concrete. In this paper, an alternative approach is presented and is evaluated acoustically and thermally. A few strips of sound absorber, arranged at intervals, are mounted flush into the concrete ceiling. To calculate the sound-absorption spectrum, an already widely publicised model (the Rayleigh approach) is used. It predicts the sound-absorption spectrum for normal sound incidence very well. For diffuse sound incidence, the difference to reverberation chamber measurements is greater, presumably because of the edge effect. The sound- absorption coefficient of the design can be tuned by skilful choice of the strip geometry, and it is significantly higher than the expected average value for the surface. On the one hand, the thermal efficiency of the components is determined by comparing the heat fluxes in the ceilings with absorber strips to an untreated reference ceiling. On the other hand, the indoor climate is investigated using a room model for office rooms of both solid and lightweight constructions. The influence of the strips (proportion of absorber area 20 %) on the thermal efficiency and indoor climate is low. Two absorber materials are examined in the strip approach: open-cell foam glass and a micro-perforated metallic absorber. While the metallic absorber displays thermal advantages, its sound absorption spectrum - even at high surface-coverage proportions - exhibits a much lower absorption coefficient than, for example, open-cell foam glass strips with only 20 % ceiling coverage. A demonstration in situ shows the potential of the absorber strips spaced at intervals. However, the method chosen in

  9. Analyzing the glass ceiling effect among radiologic technologists.

    Science.gov (United States)

    Belinsky, Susan B; Blagg, James D

    2011-01-01

    The literature has suggested that advancement within politics, academia and the health professions is influenced by gender. Purpose The authors conducted a survey to determine whether advancement was equal by gender in the radiologic science disciplines of nuclear medicine technology, radiation therapy and radiography. The survey was mailed to 900 subjects, 300 from each discipline. The discipline groups were further stratified by initial year of American Registry of Radiologic Technology certification; the authors selected 100 subjects from each discipline who initially were certified in 1978, 100 in 1988 and 100 in 1998. Approximately 33% of those selected responded. The findings of the study provided no evidence that men are promoted differentially than women. Women perceived that men were paid more for the same work. It appears that gender bias is pervasive outside of promotion decisions and, indeed, that some illegal actions (eg, sexual harassment, inappropriate gender-related interview questions) take place in radiologic science clinical settings. It is hoped that this study will set a baseline for future research on whether there is a glass ceiling effect in radiologic clinical practice and stimulate discussion of the importance of equal opportunity regardless of gender.

  10. Topological insulators Dirac equation in condensed matter

    CERN Document Server

    Shen, Shun-Qing

    2017-01-01

    This new edition presents a unified description of these insulators from one to three dimensions based on the modified Dirac equation. It derives a series of solutions of the bound states near the boundary, and describes the current status of these solutions. Readers are introduced to topological invariants and their applications to a variety of systems from one-dimensional polyacetylene, to two-dimensional quantum spin Hall effect and p-wave superconductors, three-dimensional topological insulators and superconductors or superfluids, and topological Weyl semimetals, helping them to better understand this fascinating field. To reflect research advances in topological insulators, several parts of the book have been updated for the second edition, including: Spin-Triplet Superconductors, Superconductivity in Doped Topological Insulators, Detection of Majorana Fermions and so on. In particular, the book features a new chapter on Weyl semimetals, a topic that has attracted considerable attention and has already b...

  11. Improved thermal monitoring of rotating machine insulation

    International Nuclear Information System (INIS)

    Stone, G.C.; Sedding, H.G.; Bernstein, B.S.

    1991-01-01

    Aging of motor and generator insulation is most often induced as a result of operation at high temperatures. In spite of this knowledge, stator and rotor temperatures are only crudely monitored in existing machines. In EPRI project RP2577-1, three new means of detecting machine temperatures were successfully developed. Two of the techniques, the Electronic Rotor Temperature Sensor and the Passive Rotor Temperature Sensor, were specifically developed to give point temperature readings on turbine generator rotor windings. The Insulation Sniffer allows operators to determine when any electrical insulation in a motor is overheating. Another electronic device, called the Thermal Life Indicator, helps operators and maintenance personnel determine how accumulated operation has affected the remaining life of the insulation in rotating machines. These new devices permit nuclear station operators to avoid hazardous operating conditions and will help to determine priorities for maintenance and plant life extension programs

  12. Thermal insulation performance of green roof systems

    Energy Technology Data Exchange (ETDEWEB)

    Celik, Serdar; Morgan, Susan; Retzlaff, William; Once, Orcun [southern Illinois University (United States)], e-mail: scelik@siue.edu, e-mail: smorgan@siue.edu, e-mail: wretzla@siue.edu, e-mail: oonce@siue.edu

    2011-07-01

    With the increasing costs of energy, good building insulation has become increasingly important. Among existing insulation techniques is the green roof system, which consists of covering the roof of a building envelop with plants. The aim of this paper is to assess the impact of vegetation type and growth media on the thermal performance of green roof systems. Twelve different green roof samples were made with 4 different growth media and 3 sedum types. Temperature at the sample base was recorded every 15 minutes for 3 years; the insulation behavior was then analysed. Results showed that the insulation characteristics were achieved with a combination of haydite and sedum sexangulare. This study demonstrated that the choice of growth media and vegetation is important to the green roof system's performance; further research is required to better understand the interactions between growth media and plant roots.

  13. Charge transport through superconductor/Anderson-insulator interfaces

    International Nuclear Information System (INIS)

    Frydman, A.; Ovadyahu, Z.

    1997-01-01

    We report on a study of charge transport through superconductor-insulator-superconductor and normal metal endash insulator endash superconductor structures (SIS and NIS junctions, respectively) where the insulator is of the Anderson type. Devices which are characterized by a junction resistance larger than 10 kΩ show behavior which is typical of Giaever tunnel junctions. In structures having smaller resistance, several peculiar features are observed. In the SIS junctions, Josephson coupling is detected over distances much larger then the typical insulator localization length. In addition, a series of resistance peaks appears at voltages of 2Δ/n, where Δ is the superconducting gap. The NIS Junctions exhibit a large resistance dip at subgap bias. We discuss possible interpretations of these findings and suggest that they may result from the presence of high transmission channels through the barrier region. copyright 1997 The American Physical Society

  14. Built-in unit with short-circuit insulation for hermetic cable ducts

    International Nuclear Information System (INIS)

    Tschacher, B.; Gurr, W.; Kusserow, J.; Katzmarek, W.

    1984-01-01

    The invention concerns a built-in unit with short-circuit insulation for hermetic cable ducts, especially for containments of nuclear power reactors. The short-circuit insulation is achieved by an insulation plate made from radiation-resistant insulating materials of high mechanical strength

  15. Floquet topological insulators for sound

    Science.gov (United States)

    Fleury, Romain; Khanikaev, Alexander B.; Alù, Andrea

    2016-06-01

    The unique conduction properties of condensed matter systems with topological order have recently inspired a quest for the similar effects in classical wave phenomena. Acoustic topological insulators, in particular, hold the promise to revolutionize our ability to control sound, allowing for large isolation in the bulk and broadband one-way transport along their edges, with topological immunity against structural defects and disorder. So far, these fascinating properties have been obtained relying on moving media, which may introduce noise and absorption losses, hindering the practical potential of topological acoustics. Here we overcome these limitations by modulating in time the acoustic properties of a lattice of resonators, introducing the concept of acoustic Floquet topological insulators. We show that acoustic waves provide a fertile ground to apply the anomalous physics of Floquet topological insulators, and demonstrate their relevance for a wide range of acoustic applications, including broadband acoustic isolation and topologically protected, nonreciprocal acoustic emitters.

  16. Topological insulators and topological superconductors

    CERN Document Server

    Bernevig, Andrei B

    2013-01-01

    This graduate-level textbook is the first pedagogical synthesis of the field of topological insulators and superconductors, one of the most exciting areas of research in condensed matter physics. Presenting the latest developments, while providing all the calculations necessary for a self-contained and complete description of the discipline, it is ideal for graduate students and researchers preparing to work in this area, and it will be an essential reference both within and outside the classroom. The book begins with simple concepts such as Berry phases, Dirac fermions, Hall conductance and its link to topology, and the Hofstadter problem of lattice electrons in a magnetic field. It moves on to explain topological phases of matter such as Chern insulators, two- and three-dimensional topological insulators, and Majorana p-wave wires. Additionally, the book covers zero modes on vortices in topological superconductors, time-reversal topological superconductors, and topological responses/field theory and topolo...

  17. Design and construction of the mineral insulated magnets

    International Nuclear Information System (INIS)

    Kurokawa, S.; Hirabayashi, H.; Taino, M.; Tsuchiya, K.; Yamamoto, A.

    1978-01-01

    The radiation resistant magnets with mineral insulated coils are designed and constructed. The electrical insulation of the cable is maintained by magnesium oxide in the form of a powder held around the copper hollow conductor by a copper shieth. By the direct water cooling through a hollow conductor the sometimes conflicting requirements of good insulation and high field are fulfilled. The magnets can with stand more than 10 12 rad of absorbed dose. (author)

  18. Impact of insulation and consumer behavior on natural gas consumption

    Energy Technology Data Exchange (ETDEWEB)

    van Mastrigt, P.

    1983-09-01

    The influence of insulation measures and certain changes in behavioral patterns on gas consumption for home heating has been examined, both on an annual basis and on the maximum day and at the maximum hour. By means of good insulation (cavity wall insulation and double glazing on the ground floor) annual gas consumption can be brought down by 28-35%, depending on the type of dwelling, as compared with moderate insulation. Maximum day consumption will go down by 26-33% and maximum hour consumption by no more than 20-28%. Further insulation, to current Danish standards, would enable savings of up to 72% of annual consumption, 64-66% of maximum day consumption and 52-55% of maximum hour consumption. By further night reduction from 14.5 degrees C to 12 degrees C 2% of the annual consumption can be saved in moderately insulated dwellings. It also leads, however, to an increase in maximum hour consumption by some 11%. In heavily insulated dwellings further night reduction does not yield any additional savings on the annual consumption. By lowering the thermostat setting by 2 degrees C in the daytime annual consumption in a moderately insulated dwelling can be cut by 9%. With increasing insulation level the savings will get higher, up to 11% in heavily insulated dwellings. Drawing the curtains during the evening and night may yield savings of 4-6% depending on the ratio of glass surface to total outer wall surface. These savings will be lower as the insulation level increases. The results of the study have been converted to the overall domestic natural gas consumption in the Netherlands. In 1985 the annual consumption will be 7% lower than in 1978 as a result of insulation measures and changes in consumer behavior, even at a rise in the total number of connections. Maximum day consumption will be 5% lower and maximum hour consumption will be virtually the same. This trend became already manifest during the 1978-1982 period.

  19. Correlation analysis between ceramic insulator pollution and acoustic emissions

    Directory of Open Access Journals (Sweden)

    Benjamín Álvarez-Nasrallah

    2015-01-01

    Full Text Available Most of the studies related to insulator pollution are normally performed based on individual analysis among leakage current, relative humidity and equivalent salt deposit density (ESDD. This paper presents a correlation analysis between the leakage current and the acoustic emissions measured in a 230 kV electrical substations in the city of Barranquilla, Colombia. Furthermore, atmospheric variables were considered to develop a characterization model of the insulator contamination process. This model was used to demonstrate that noise emission levels are a reliable indicator to detect and characterize pollution on high voltage insulators. The correlation found amount the atmospheric, electrical and sound variables allowed to determine the relations for the maintenance of ceramic insulators in high-polluted areas. In this article, the results on the behavior of the leakage current in ceramic insulators and the sound produced with different atmospheric conditions are shown, which allow evaluating the best time to clean the insulator at the substation. Furthermore, by experimentation on site and using statistical models, the correlation between ambient variables and the leakage current of insulators in an electrical substation was obtained. Some of the problems that bring the external noise were overcome using multiple microphones and specialized software that enabled properly filter the sound and better measure the variables.

  20. Electrical machining method of insulating ceramics

    International Nuclear Information System (INIS)

    Fukuzawa, Y.; Mohri, N.; Tani, T.

    1999-01-01

    This paper describes a new electrical discharge machining method for insulating ceramics using an assisting electrode with either a sinking electrical discharge machine or a wire electrical discharge machine. In this method, the metal sheet or mesh is attached to the ceramic surface as an assisting material for the discharge generation around the insulator surface. When the machining condition changes from the attached material to the workpiece, a cracked carbon layer is formed on the workpiece surface. As this layer has an electrical conductivity, electrical discharge occurs in working oil between the tool electrode and the surface of the workpiece. The carbon is formed from the working oil during this electrical discharge. Even after the material is machined, an electrical discharge occurs in the gap region between the tool electrode and the ceramic because an electrically conductive layer is generated continuously. Insulating ceramics can be machined by the electrical discharge machining method using the above mentioned surface modification phenomenon. In this paper the authors show a machined example demonstrating that the proposed method is available for machining a complex shape on insulating ceramics. Copyright (1999) AD-TECH - International Foundation for the Advancement of Technology Ltd

  1. Tetradymites as thermoelectrics and topological insulators

    Science.gov (United States)

    Heremans, Joseph P.; Cava, Robert J.; Samarth, Nitin

    2017-10-01

    Tetradymites are M2X3 compounds — in which M is a group V metal, usually Bi or Sb, and X is a group VI anion, Te, Se or S — that crystallize in a rhombohedral structure. Bi2Se3, Bi2Te3 and Sb2Te3 are archetypical tetradymites. Other mixtures of M and X elements produce common variants, such as Bi2Te2Se. Because tetradymites are based on heavy p-block elements, strong spin-orbit coupling greatly influences their electronic properties, both on the surface and in the bulk. Their surface electronic states are a cornerstone of frontier work on topological insulators. The bulk energy bands are characterized by small energy gaps, high group velocities, small effective masses and band inversion near the centre of the Brillouin zone. These properties are favourable for high-efficiency thermoelectric materials but make it difficult to obtain an electrically insulating bulk, which is a requirement of topological insulators. This Review outlines recent progress made in bulk and thin-film tetradymite materials for the optimization of their properties both as thermoelectrics and as topological insulators.

  2. Numerical simulations of quantum many-body systems with applications to superfluid-insulator and metal-insulator transitions

    International Nuclear Information System (INIS)

    Niyaz, P.

    1993-01-01

    Quantum Monte Carlo techniques were used to study two quantum many-body systems, the one-dimensional extended boson-Hubbard Hamiltonian, a model of superfluid-insulator quantum phase transitions, and the two-dimensional Holstein Model, a model for electron-phonon interactions. For the extended boson-Hubbard model, the authors studied the ground state properties at commensurate filling (density = 1) and half-integer filling (density = 1/2). At commensurate filling, the system has two possible insulating phases for strong coupling. If the on-site repulsion dominates, the system freezes into an insulating phase where each site is singly occupied. If the intersite repulsion dominates, doubly occupied and empty sites alternate. At weak coupling, the system becomes a superfluid. The authors investigated the order of phase transitions between these different phases. At half-integer filling, the authors found one strong coupling insulating phase, where singly occupied and empty sites alternate, and a weak coupling superfluid phase. The authors also investigated the possibility of a supersolid phase and found no clear evidence of such a new phase. For the electron-phonon (Holstein) model, the authors focused on the finite temperature phase transition from a metallic state to an insulating charge density wave (CDW) state as the temperature is lowered. The authors present the first calculation of the spectral density from Monte Carlo data for this system. The authors also investigated the formation of a CDW state as a function of various parameters characterizing the electron-phonon interactions. Using these numerical results as benchmarks, the authors then investigated different levels of Migdal approximations. The authors found the solutions of a set of gapped Migdal-Eliashberg equations agreed qualitatively with the Monte Carlo results

  3. Review Symposium; Dancing on the Ceiling: A Study of Women Managers in Education, by Valerie Hall. London: Paul Chapman, 1996.

    Science.gov (United States)

    Hall, Valerie; Gronn, Peter; Jenkin, Mazda; Power, Sally; Reynolds, Cecilia

    1999-01-01

    Hall and four colleagues review "Dancing on the Ceiling: A Study of Women Managers in Education" (Paul Chapman, 1996). Reviewers agree that Hall's profiles of six British elementary and secondary women headteachers should improve readers' understanding of female managers' development and their preference for "soft,"…

  4. Topological insulators fundamentals and perspectives

    CERN Document Server

    Ortmann, Frank; Valenzuela, Sergio O

    2015-01-01

    There are only few discoveries and new technologies in physical sciences that have the potential to dramatically alter and revolutionize our electronic world. Topological insulators are one of them. The present book for the first time provides a full overview and in-depth knowledge about this hot topic in materials science and condensed matter physics. Techniques such as angle-resolved photoemission spectrometry (ARPES), advanced solid-state Nuclear Magnetic Resonance (NMR) or scanning-tunnel microscopy (STM) together with key principles of topological insulators such as spin-locked electronic

  5. The glass ceiling: A biological phenomenon.

    Science.gov (United States)

    Schulpen, Tom W J

    2017-09-01

    Many brilliant and ambitious young women lose their drive for top careers after childbirth. New maternal impulses are at odds with their original ambitions and for many mothers stress and frustration will be the result as they have to combine child care with workweeks of 60-80h to reach or remain at the top. Pregnancy hormones modify the female's brain as has been demonstrated already for decades in animals. This brain plasticity due to adult neurogenesis in the so called maternal circuitry of the limbic system is long-lasting and perhaps lifelong. In humans hormonal and neuro-imaging studies show ample evidence for fundamental and long lasting pregnancy induced brain changes, not only in the limbic system, but also in the cortical networks like theory of mind and mirror neuron system. Recent research shows pronounced and long lasting brain changes in several of these areas. It can be concluded that there exists a maternal brain that drives mother's behaviour and priorities. Research in men shows that the more fathers are involved in raising their children, the more caring behaviour they develop. Structural anatomical changes are found in neural regions involved in parental motivation. These studies show that brain plasticity in fathers is experience dependent. In Nordic countries, a policy of paid paternal leave followed by a flexible shared parental leave, stimulates fatherly behaviour. This might reduce men's eagerness for top careers, thus creating better opportunities for women. Demolition of women's glass ceiling starts with the father. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Effects of radiation on insulation materials

    International Nuclear Information System (INIS)

    Poehlchen, R.

    1992-01-01

    This presentation will concentrate on the insulation materials which are suitable for the insulation of superconducting magnets for fusion. For the next generation of fusion machines with magnetic confinement as NET and ITER general agreement exists that the insulation will consist of fibre reinforced organic matrix material, a composite. Much effort has been put into the investigation of the radiation resistance of such materials during the last 20-30 years, see in particular the numerous reports of accelerator laboratories on this subject. But very few of the published data are relevant for the superconducting magnets of fusion machines. Either the irradiation and testing was carried out at RT or LN 2 temperature and/or the irradiation spectrum was not representative for a fusion machine and/or the materials investigated are not applicable for the insulation of S.C. fusion magnets. Therefore test programs have been launched recently, one by the NET team. The intention of the first chapter is to give guidance on the choice of materials which are suitable as insulation materials from a more general point of view. A good understanding of the coil manufacturing process is needed for this purpose. The second chapter explains the irradiation spectrum seen by the magnets. A third chapter does present the NET/ITER test programme. Step 1 was completed at the end of 1989, the second step will be carried out in the autumn of 1991. Finally, a general assessment of materials and testing methods will be given with recommendations for further testing

  7. External Insulation of Masonry Walls and Wood Framed Walls

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P.

    2013-01-01

    The use of exterior insulation on a building is an accepted and effective means to increase the overall thermal resistance of the assembly that also has other advantages of improved water management and often increased air tightness of building assemblies. For thin layers of insulation (1" to 1 1/2"), the cladding can typically be attached directly through the insulation back to the structure. For thicker insulation layers, furring strips have been added as a cladding attachment location. This approach has been used in the past on numerous Building America test homes and communities (both new and retrofit applications), and has been proven to be an effective and durable means to provide cladding attachment. However, the lack of engineering data has been a problem for many designers, contractors, and code officials. This research project developed baseline engineering analysis to support the installation of thick layers of exterior insulation on existing masonry and frame walls. Furthermore, water management details necessary to integrate windows, doors, decks, balconies and roofs were created to provide guidance on the integration of exterior insulation strategies with other enclosure elements.

  8. Ginsburg-Landau equation around the superconductor-insulator transition

    International Nuclear Information System (INIS)

    Ng, T.K.

    1991-01-01

    Based on the scaling theory of localization, we construct a Ginsburg-Landau (GL) equation for superconductors in an arbitrary strength of disordered potential. Using this GL equation, we reexamine the criteria for the superconductor-insulator transition and find that the transition to a localized superconductor can happen on both sides of the (normal) metal-insulator transition, in contrast to a previous prediction by Ma and Lee [Phys. Rev. B 32, 5658 (1985)] that the transition can only be on the insulator side. Furthermore, by comparing our theory with a recent scaling theory of dirty bosons by Fisher et al. [Phys. Rev. Lett. 64, 587 (1990)], we conclude that nontrivial crossover behavior in transport properties may occur in the vicinity of the superconductor-insulator transition

  9. Synthesis and characterization of innovative insulation materials

    Directory of Open Access Journals (Sweden)

    Skaropoulou Aggeliki

    2018-01-01

    Full Text Available Insulation elements are distinguished in inorganic fibrous and organic foamed materials. Foamed insulation materials are of great acceptance and use, but their major disadvantage is their flammability. In case of fire, they tend to transmit the flame producing toxic gases. In this paper, the synthesis and characterization of innovative inorganic insulation materials with properties competitive to commercial is presented. Their synthesis involves the mixing of inorganic raw material and water with reinforcing agent or/and foaming agent leading to the formation of a gel. Depending on raw materials nature, the insulation material is produced by freeze drying or ambient drying techniques of the gel. The raw material used are chemically benign and abundantly available materials, or industrial by-products and the final products are non-toxic and, in some cases, non-flammable. Their density and thermal conductivity was measured and found 0.02-0.06 g/cm3 and 0.03-0.04 W/mK, respectively.

  10. Infrared circular photogalvanic effect in topological insulators

    Science.gov (United States)

    Luo, Siyuan

    2018-04-01

    Topological insulators have attracted a lot of attention in recent years due to its unique phenomena. Circular photogalvanic effect (CPGE) is one of the important phenomena in topological insulators. Bi2Se3, as one of the 3D topological insulators, consist of a single Dirac cone at the Γ point in k-space [1], corresponding to the surface states. Controlled by the Berry curvature of the surface band, the dominant photo response due to the interband transition is helicity dependent [2]. In addition, due to the spin-momentum locking in topological insulators' surface, the sign of spin-angular-momentum of obliquely incident light and photo currents are locked together. On the other hand, Bi2Se3 consists of quintuple layers which make it possible to be exfoliated and transferred based on graphene fabrication. In this paper, Bi2Se3 devices were fabricated and Ohm contact was achieved. We experimentally demonstrated the CPGE in Bi2Se3 using 1550nm incident laser.

  11. HiPTI - High Performance Thermal Insulation, Annex 39 to IEA/ECBCS-Implementing Agreement. Vacuum insulation in the building sector. Systems and applications

    Energy Technology Data Exchange (ETDEWEB)

    Binz, A.; Moosmann, A.; Steinke, G.; Schonhardt, U.; Fregnan, F. [Fachhochschule Nordwestschweiz (FHNW), Muttenz (Switzerland); Simmler, H.; Brunner, S.; Ghazi, K.; Bundi, R. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Heinemann, U.; Schwab, H. [ZAE Bayern, Wuerzburg (Germany); Cauberg, H.; Tenpierik, M. [Delft University of Technology, Delft (Netherlands); Johannesson, G.; Thorsell, T. [Royal Institute of Technology (KTH), Stockholm (Sweden); Erb, M.; Nussbaumer, B. [Dr. Eicher und Pauli AG, Basel and Bern (Switzerland)

    2005-07-01

    This final report on vacuum insulation panels (VIP) presents and discusses the work done under IEA/Energy Conservation in Buildings and Community Systems (ECBCS) Annex 39, subtask B on the basis of a wide selection of reports from practice. The report shows how the building trade deals with this new material today, the experience gained and the conclusions drawn from this work. As well as presenting recommendations for the practical use of VIP, the report also addresses questions regarding the effective insulation values to be expected with current VIP, whose insulation performance is stated as being a factor of five to eight times better than conventional insulation. The introduction of this novel material in the building trade is discussed. Open questions and risks are examined. The fundamentals of vacuum insulation panels are discussed and the prerequisites, risks and optimal application of these materials in the building trade are examined.

  12. Insulation systems for liquid methane fuel tanks for supersonic cruise aircraft

    Science.gov (United States)

    Brady, H. F.; Delduca, D.

    1972-01-01

    Two insulation systems for tanks containing liquid methane in supersonic cruise-type aircraft were designed and tested after an extensive materials investigation. One system is an external insulation and the other is an internal wet-type insulation system. Tank volume was maximized by making the tank shape approach a rectangular parallelopiped. One tank was designed to use the external insulation and the other tank to use the internal insulation. Performance of the external insulation system was evaluated on a full-scale tank under the temperature environment of -320 F to 700 F and ambient pressures of ground-level atmospheric to 1 psia. Problems with installing the internal insulation on the test tank prevented full-scale evaluation of performance; however, small-scale testing verified thermal conductivity, temperature capability, and installed density.

  13. Composite bulk Heat Insulation Made of loose Mineral and Organic Aggregate

    Directory of Open Access Journals (Sweden)

    Namsone Eva

    2015-12-01

    Full Text Available The task of building energy-efficiency is getting more important. Every house owner wishes to save up exploitation costs of heating, cooling, hot water production, ventilation, etc. and find cost-effective investments. One of the ways to reduce greenhouse gas emissions (GHGE is to minimize the heat transfer through the building by insulating it. Loose heat insulation is a good alternative to traditional board insulation, it is simple in use and cost-effective. Main drawback of this insulation is tendency to compact during exploitation. In the frame of this research composite loose heat insulation is elaborated, consisting on porous mineral foamed glass aggregate and local organic fiber materials (hemp and flaxen shives. Composite bulk insulation is an alternative solution which combines heat insulating properties and mechanical stability.

  14. Effects of insulating vanadium oxide composite in concomitant mixed phases via interface barrier modulations on the performance improvements in metal-insulator-metal diodes

    Directory of Open Access Journals (Sweden)

    Kaleem Abbas

    2018-03-01

    Full Text Available The performance of metal-insulator-metal diodes is investigated for insulating vanadium oxide (VOx composite composed of concomitant mixed phases using the Pt metal as the top and the bottom electrodes. Insulating VOx composite in the Pt/VOx/Pt diode exhibits a high asymmetry of 10 and a very high sensitivity of 2,135V−1 at 0.6 V. The VOx composite provides Schottky-like barriers at the interface, which controls the current flow and the trap-assisted conduction mechanism. Such dramatic enhancement in asymmetry and rectification performance at low applied bias may be ascribed to the dynamic control of the insulating and metallic phases in VOx composites. We find that the nanostructure details of the insulating VOx layer can be critical in enhancing the performance of MIM diodes.

  15. Impact of Moistened Bio-insulation on Whole Building Energy Use

    Directory of Open Access Journals (Sweden)

    Latif Eshrar

    2017-01-01

    Full Text Available One of the key properties of hemp insulation is its moisture adsorption capacity. Adsorption of moisture can increase both thermal conductivity and heat capacity of the insulation. The current study focuses on the effect of moisture induced thermal mass of installed hemp insulation on the whole building energy use. Hygrothermal and thermal simulations were performed using the CIBSE TRY weather data of Edinburgh and Birmingham with the aid of following simulation tools: WUFI and IES. Following simplified building types were considered: building-1 with dry hemp wall and loft insulations, building-2 with moistened hemp wall and loft insulation and building-3 with stone wool insulation. It was observed that the overall conditioning load of building-1 was 1.2 to 2.3% higher than building-2 and 3. However, during the summer season, the cooling load of building-2 was 3-7.5% lower than the other buildings. It implies that, moistened insulation can potentially mitigate the effect of increasing cooling degree days induced by global warming.

  16. Radiaton-resistant electrical insulation on the base of cement binders

    International Nuclear Information System (INIS)

    Afanas'ev, V.V.; Korenevskij, V.V.; Pisachev, S.Yu.

    1985-01-01

    The problems of designing radiation-resistant electrical insulations on the base of BATs and Talum cements for the UNK magnets operating under constant and pulse modes are discussed. The data characterizing dielectrical ad physico-mechanical properties of 25 various compositions are given. Two variants of manufacturing coils are considered: solid and with the use of asbestos tape impregnated with aluminous cement solution. The data obtained testify to the fact that the advantages of insulation on Talum cement are raised radiation resistance, high strength (particularly compression strength), weak porosity, high elasticity modulus and high thermal conductivity. BATs cement insulation is characterized by high radiation resistance, absence of shrinkage, rather low elasticity modulus and high dielectrical characteristics under normal conditions. The qualities of the solid insulation variant are its high technological effectiveness and posibility to fill up the spaces of complex configuration. In case of using as solid insulation Talum cement, however special measures for moisture removal are required. The advantage of insulation on the base of the asbestos tape is its reliability. For complex configuration magnets, however to realize is such insulation somewhat difficult

  17. Parametric Investigation of Optimum Thermal Insulation Thickness for External Walls

    Directory of Open Access Journals (Sweden)

    Omer Kaynakli

    2011-06-01

    Full Text Available Numerous studies have estimated the optimum thickness of thermal insulation materials used in building walls for different climate conditions. The economic parameters (inflation rate, discount rate, lifetime and energy costs, the heating/cooling loads of the building, the wall structure and the properties of the insulation material all affect the optimum insulation thickness. This study focused on the investigation of these parameters that affect the optimum thermal insulation thickness for building walls. To determine the optimum thickness and payback period, an economic model based on life-cycle cost analysis was used. As a result, the optimum thermal insulation thickness increased with increasing the heating and cooling energy requirements, the lifetime of the building, the inflation rate, energy costs and thermal conductivity of insulation. However, the thickness decreased with increasing the discount rate, the insulation material cost, the total wall resistance, the coefficient of performance (COP of the cooling system and the solar radiation incident on a wall. In addition, the effects of these parameters on the total life-cycle cost, payback periods and energy savings were also investigated.

  18. The Relationship between Glass Ceiling Barriers to Woman and Perceived Organizational Justice in Working Life

    OpenAIRE

    Özyer, Kubilay; Azizoğlu, Öznur

    2014-01-01

    Women are participating more and more to the working life nowadays. But they couldn’t adequately take part in high management positions. There are too many reasons which effect this case. Especially; in some research it suggested that women couldn’t go beyond to a barrier, “glass ceiling”, which is an invisible obstacle for women, and they have to work under it. For these reason; in this study firstly, the terms of glass ceiling obstacle to women and perceived organizational justice and the i...

  19. Insulating materials for cables: state of the technology and future developments

    Energy Technology Data Exchange (ETDEWEB)

    Blechschmidt, H H [Hessische Elektrizitaets-A.G., Darmstadt (Germany, F.R.)

    1977-02-01

    This article gives a summary of old and new insulating materials for electrical cables. The electrical properties of some polymer insulating materials (PVC, polyethelene (PE), polymerised polyethelene (VPE), polypropylene) are compared in a table with the properties of paper insulation. The changeover from oiled paper to plastic insulation is almost complete for low voltage cables. Soft PVC is the dominant insulating material in this field. For medium voltage cables (10 kV and 20 kV supplies) and for high voltage cables (60 kV and 110 kV supplies) there is a trend to plastic PE/VPE, because these insulating materials have better electrical properties than PVC.

  20. Study of thermal conductivity of multilayer insulation

    International Nuclear Information System (INIS)

    Dutta, D.; Sundaram, S.; Nath, G.K.; Sethuram, N.P.; Chandrasekharan, T.; Varadarajan, T.G.

    1994-01-01

    This paper presents experimental determination of the apparent thermal conductivity of multilayer insulation for a cryogenic system. The variation of thermal conductivity with residual gas pressure is studied and the optimum vacuum for good insulating performance is determined. Evaporation loss technique for heat-inleak determination is employed. (author)

  1. Deposit Rate Ceilings as a Tool of Prudential Regulation

    Directory of Open Access Journals (Sweden)

    Janusz Krajewski

    2007-12-01

    Full Text Available The purpose of the paper is to present one of prudential regulation instruments in an environment that favors to engage in moral hazard behavior. The last decades proved that there is a link between financial liberalization and banking crises. In order to avoid crises and prevent banks engaging in gambling behavior, the system of prudential regulations has been implemented. The emphasis has been placed on the use of capital requirements, typically using the BIS standard developed in the Basel Accord.As the excessive reliance on capital requirements can become costly for the banks and lead to loose their franchise value and undermine incentives for prudent investing. The instrument that can create the franchise value, i.e. earning profits in the current period and in the future, is a policy of deposit rate controls. In the paper was also revealed why the policy of setting interest rate ceiling on deposits had not achieved its intended objectives, especially in the view of the fail of the Regulation Q policy.

  2. Recent Progress in Electrical Insulation Techniques for HTS Power Apparatus

    Science.gov (United States)

    Hayakawa, Naoki; Kojima, Hiroki; Hanai, Masahiro; Okubo, Hitoshi

    This paper describes the electrical insulation techniques at cryogenic temperatures, i.e. Cryodielectrics, for HTS power apparatus, e.g. HTS power transmission cables, transformers, fault current limiters and SMES. Breakdown and partial discharge characteristics are discussed for different electrical insulation configurations of LN2, sub-cooled LN2, solid, vacuum and their composite insulation systems. Dynamic and static insulation performances with and without taking account of quench in HTS materials are also introduced.

  3. 10 CFR Appendix U to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans 1. Scope... significant digits as the previous step. Round the final energy consumption value to the nearest whole number...

  4. Analysis of Pathogenesis of Autoimmune Insulitis in NOD Mice: Adoptive Transfer Experiments of Insulitis in ILI and NOD Nude Mice

    OpenAIRE

    Nakamura, Moritaka; Nishimura, Masahiko; Koide, Yukio; Takato, O.Yoshida

    2003-01-01

    In an effort to study the pathophysiological events in the development of insulitis in NOD mice, we have developed ILI- and NOD-nu/nu mice. ILI mice are a nondiabetic inbred strain but are derived from the same Jcl:ICR mouse as NOD mice and share the same H-2 allotype with NOD mice. Splenocytes and CD4+ cells from diabetic NOD mice appeared to transfer insulitis to ILI-nu/nu mice, suggesting that ILI mice already express autoantigen(s) responsible for insulitis. But reciprocal thymic grafts f...

  5. Ferromagnetic-insulators-modulated transport properties on the surface of a topological insulator

    International Nuclear Information System (INIS)

    Guo Jun-Ji; Liao Wen-Hu

    2014-01-01

    Transport properties on the surface of a topological insulator (TI) under the modulation of a two-dimensional (2D) ferromagnet/ferromagnet junction are investigated by the method of wave function matching. The single ferromagnetic barrier modulated transmission probability is expected to be a periodic function of the polarization angle and the planar rotation angle, that decreases with the strength of the magnetic proximity exchange increasing. However, the transmission probability for the double ferromagnetic insulators modulated n—n junction and n—p junction is not a periodic function of polarization angle nor planar rotation angle, owing to the combined effects of the double ferromagnetic insulators and the barrier potential. Since the energy gap between the conduction band and the valence band is narrowed and widened respectively in ranges of 0 ≤ θ < π/2 and π/2 < θ ≤ π, the transmission probability of the n—n junction first increases rapidly and then decreases slowly with the increase of the magnetic proximity exchange strength. While the transmission probability for the n—p junction demonstrates an opposite trend on the strength of the magnetic proximity exchange because the band gaps contrarily vary. The obtained results may lead to the possible realization of a magnetic/electric switch based on TIs and be useful in further understanding the surface states of TIs

  6. Assessment of fibrous insulation materials for the selenide isotope generator system

    International Nuclear Information System (INIS)

    Wei, G.C; Tennery, V.J.

    1977-11-01

    Fibrous insulations for use in the converter and the heat source of the radioisotope-powered, selenide element, thermoelectric generator (selenide isotope generator) are assessed. The most recent system design and material selection basis is presented. Several fibrous insulation materials which have the potential for use as load-bearing or nonload-bearing thermal insulations are reviewed, and thermophysical properties supplied by manufacturers or published in the literature are presented. Potential problems with the application of fibrous insulations in the selenide isotope generator are as follows: compatibility with graphite, the thermoelectric elements, and the isolation hot frame; devitrification, grain growth, and sintering with an accompanying degradation of insulation quality; impurity diffusion from the insulation to adjoining structures; outgassing and storage of fibrous materials. Areas in which thermophysical data or quantitative information on the insulation and structural stability is lacking are identified

  7. Polyimide Foams Offer Superior Insulation

    Science.gov (United States)

    2012-01-01

    At Langley Research Center, Erik Weiser and his colleagues in the Advanced Materials and Processing Branch were working with a new substance for fabricating composites for use in supersonic aircraft. The team, however, was experiencing some frustration. Every time they tried to create a solid composite from the polyimide (an advanced polymer) material, it bubbled and foamed. It seemed like the team had reached a dead end in their research - until they had another idea. "We said, This isn t going to work for composites, but maybe we could make a foam out of it," Weiser says. "That was kind of our eureka moment, to see if we could go in a whole other direction. And it worked." Weiser and his colleagues invented a new kind of polyimide foam insulation they named TEEK. The innovation displayed a host of advantages over existing insulation options. Compared to other commercial foams, Weiser explains, polyimide foams perform well across a broad range of temperatures, noting that the NASA TEEK foams provide effective structural insulation up to 600 F and down to cryogenic temperatures. The foam does not burn or off-gas toxic fumes, and even at -423 F - the temperature of liquid hydrogen - the material stays flexible. The inventors could produce the TEEK foam at a range of densities, from 0.5 pounds per cubic foot up to 20 pounds per cubic foot, making the foam ideal for a range of applications, including as insulation for reusable launch vehicles and for cryogenic tanks and lines. They also developed a unique, friable balloon format for manufacturing the foam, producing it as hollow microspheres that allowed the foam to be molded and then cured into any desired shape - perfect for insulating pipes of different sizes and configurations. The team s originally unplanned invention won an "R&D 100" award, and a later form of the foam, called LaRC FPF-44 (Spinoff 2009), was named "NASA Invention of the Year" in 2007.

  8. Hierarchical rank and women's organizational mobility: glass ceilings in corporate law firms.

    Science.gov (United States)

    Gorman, Elizabeth H; Kmec, Julie A

    2009-03-01

    This article revives the debate over whether women's upward mobility prospects decline as they climb organizational hierarchies. Although this proposition is a core element of the "glass ceiling" metaphor, it has failed to gain strong support in previous research. The article establishes a firm theoretical foundation for expecting an increasing female disadvantage, with an eye toward defining the scope conditions and extending the model to upper-level external hires. The approach is illustrated in an empirical setting that meets the proposed scope conditions: corporate law firms in the United States. Results confirm that in this setting, the female mobility disadvantage is greater at higher organizational levels in the case of internal promotions, but not in the case of external hires.

  9. Aharonov–Bohm interference in topological insulator nanoribbons

    KAUST Repository

    Peng, Hailin

    2009-12-13

    Topological insulators represent unusual phases of quantum matter with an insulating bulk gap and gapless edges or surface states. The two-dimensional topological insulator phase was predicted in HgTe quantum wells and confirmed by transport measurements. Recently, Bi2 Se3 and related materials have been proposed as three-dimensional topological insulators with a single Dirac cone on the surface, protected by time-reversal symmetry. The topological surface states have been observed by angle-resolved photoemission spectroscopy experiments. However, few transport measurements in this context have been reported, presumably owing to the predominance of bulk carriers from crystal defects or thermal excitations. Here we show unambiguous transport evidence of topological surface states through periodic quantum interference effects in layered single-crystalline Bi2 Se3 nanoribbons, which have larger surface-to-volume ratios than bulk materials and can therefore manifest surface effects. Pronounced Aharonov-Bohm oscillations in the magnetoresistance clearly demonstrate the coherent propagation of two-dimensional electrons around the perimeter of the nanoribbon surface, as expected from the topological nature of the surface states. The dominance of the primary h/e oscillation, where h is Plancks constant and e is the electron charge, and its temperature dependence demonstrate the robustness of these states. Our results suggest that topological insulator nanoribbons afford promising materials for future spintronic devices at room temperature.

  10. Improving the reliability of stator insulation system in rotating machines

    International Nuclear Information System (INIS)

    Gupta, G.K.; Sedding, H.G.; Culbert, I.M.

    1997-01-01

    Reliable performance of rotating machines, especially generators and primary heat transport pump motors, is critical to the efficient operation on nuclear stations. A significant number of premature machine failures have been attributed to the stator insulation problems. Ontario Hydro has attempted to assure the long term reliability of the insulation system in critical rotating machines through proper specifications and quality assurance tests for new machines and periodic on-line and off-line diagnostic tests on machines in service. The experience gained over the last twenty years is presented in this paper. Functional specifications have been developed for the insulation system in critical rotating machines based on engineering considerations and our past experience. These specifications include insulation stress, insulation resistance and polarization index, partial discharge levels, dissipation factor and tip up, AC and DC hipot tests. Voltage endurance tests are specified for groundwall insulation system of full size production coils and bars. For machines with multi-turn coils, turn insulation strength for fast fronted surges in specified and verified through tests on all coils in the factory and on samples of finished coils in the laboratory. Periodic on-line and off-line diagnostic tests were performed to assess the condition of the stator insulation system in machines in service. Partial discharges are measured on-line using several techniques to detect any excessive degradation of the insulation system in critical machines. Novel sensors have been developed and installed in several machines to facilitate measurements of partial discharges on operating machines. Several off-line tests are performed either to confirm the problems indicated by the on-line test or to assess the insulation system in machines which cannot be easily tested on-line. Experience with these tests, including their capabilities and limitations, are presented. (author)

  11. A water blown urethane insulation for use in cryogenic environments

    Science.gov (United States)

    Blevins, Elana; Sharpe, Jon

    1995-01-01

    Thermal Protection Systems (TPS) of NASA's Space Shuttle External Tank include polyurethane and polyisocyanurate modified polyurethane foam insulations. These insulations, currently foamed with CFC 11 blowing agent, serve to maintain cryogenic propellant quality, maintain the external tank structural temperature limits, and minimize the formation of ice and frost that could potentially damage the ceramic insulation on the space shuttle orbiter. During flight the external tank insulations are exposed to mechanical, thermal and acoustical stresses. TPS must pass cryogenic flexure and substrate adhesion tests at -253 C, aerothermal and radiant heating tests at fluxes up to approximately 14 kilowatts per square meter, and thermal conductivity tests at cryogenic and elevated temperatures. Due to environmental concerns, the polyurethane insulation industry and the External Tank Project are tasked with replacing CFC 11. The flight qualification of foam insulations employing HCFC 141b as a foaming agent is currently in progress; HCFC 141b blown insulations are scheduled for production implementation in 1995. Realizing that the second generation HCFC blowing agents are an interim solution, the evaluation of third generation blowing agents with zero ozone depletion potential is underway. NASA's TPS Materials Research Laboratory is evaluating third generation blowing agents in cryogenic insulations for the External Tank; one option being investigated is the use of water as a foaming agent. A dimensionally stable insulation with low friability, good adhesion to cryogenic substrates, and acceptable thermal conductivity has been developed with low viscosity materials that are easily processed in molding applications. The development criteria, statistical experimental approach, and resulting foam properties will be presented.

  12. Improved design of a high-voltage vacuum-insulator interface

    Directory of Open Access Journals (Sweden)

    W. A. Stygar

    2005-05-01

    Full Text Available We have conducted a series of experiments designed to measure the flashover strength of various azimuthally symmetric 45° vacuum-insulator configurations. The principal objective of the experiments was to identify a configuration with a flashover strength greater than that of the standard design, which consists of a 45° polymethyl-methacrylate (PMMA insulator between flat electrodes. The thickness d and circumference C of the insulators tested were held constant at 4.318 and 95.74 cm, respectively. The peak voltage applied to the insulators ranged from 0.8 to 2.2 MV. The rise time of the voltage pulse was 40–60 ns; the effective pulse width [as defined in Phys. Rev. ST Accel. Beams 7, 070401 (2004PRABFM1098-440210.1103/PhysRevSTAB.7.070401] was on the order of 10 ns. Experiments conducted with flat aluminum electrodes demonstrate that the flashover strength of a crosslinked polystyrene (Rexolite insulator is (18±7% higher than that of PMMA. Experiments conducted with a Rexolite insulator and an anode plug, i.e., an extension of the anode into the insulator, demonstrate that a plug can increase the flashover strength by an additional (44±11%. The results are consistent with the Anderson model of anode-initiated flashover, and confirm previous measurements. It appears that a Rexolite insulator with an anode plug can, in principle, increase the peak electromagnetic power that can be transmitted across a vacuum interface by a factor of [(1.18(1.44]^{2}=2.9 over that which can be achieved with the standard design.

  13. Cellulose insulation as an air barrier

    Energy Technology Data Exchange (ETDEWEB)

    Manning, K.

    1989-10-01

    The objective of this study was to determine if a wet sprayed cellulose wall insulation system would function satisfactorily without use of a polyethylene air/vapour barrier. The research was designed to demonstrate that this particular insulation system would form enough of a barrier to air leakage, that moisture accumulation from condensation and vapour diffusion would be insignificant. Field work conducted in Alberta, involved construction of a conventional duplex housing unit which was insulated with wet sprayed cellulose in the exterior walls and dry loose-fill cellulose in the attic areas. One half of the unit did not have a polyethylene air/vapor barrier installed. Air leakage and exterior wall moisture levels were monitored for a year following construction. Data collected during this time indicated that the moisture added to the walls during the insulating process was dissipated over the study period. The presence of polyethylene sheeting had no significant effect on the moisture levels in either the wall or attic areas of the test structure. On the other hand, testing indicated that the use of polyethylene sheeting in the wall system did serve to improve blower door air test results. In conclusion, although the air leakage resistance apparently provided by the polyethylene sheeting is significant, the amount is probably not more than could otherwise be obtained by more careful attention to sealing procedures such as those used in the airtight drywall technique. A more important finding is that the use of polyethylene sheeting is not essential in a structure which has the degree of air leakage resistance provided by the insulation system used in this project. 6 figs., 2 tabs.

  14. External Insulation of Masonry Walls and Wood Framed Walls

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P. [Building Science Corporation, Somerville, MA (United States)

    2013-01-01

    The use of exterior insulation on a building is an accepted and effective means to increase the overall thermal resistance of the assembly that also has other advantages of improved water management and often increased air tightness of building assemblies. For thin layers of insulation (1” to 1 ½”), the cladding can typically be attached directly through the insulation back to the structure. For thicker insulation layers, furring strips have been added as a cladding attachment location. This approach has been used in the past on numerous Building America test homes and communities (both new and retrofit applications), and has been proven to be an effective and durable means to provide cladding attachment. However, the lack of engineering data has been a problem for many designers, contractors, and code officials. This research project developed baseline engineering analysis to support the installation of thick layers of exterior insulation on existing masonry and frame walls. Furthermore, water management details necessary to integrate windows, doors, decks, balconies and roofs were created to provide guidance on the integration of exterior insulation strategies with other enclosure elements.

  15. Tank Insulation

    Science.gov (United States)

    1979-01-01

    For NASA's Apollo program, McDonnell Douglas Astronautics Company, Huntington Beach, California, developed and built the S-IVB, uppermost stage of the three-stage Saturn V moonbooster. An important part of the development task was fabrication of a tank to contain liquid hydrogen fuel for the stage's rocket engine. The liquid hydrogen had to be contained at the supercold temperature of 423 degrees below zero Fahrenheit. The tank had to be perfectly insulated to keep engine or solar heat from reaching the fuel; if the hydrogen were permitted to warm up, it would have boiled off, or converted to gaseous form, reducing the amount of fuel available to the engine. McDonnell Douglas' answer was a supereffective insulation called 3D, which consisted of a one-inch thickness of polyurethane foam reinforced in three dimensions with fiberglass threads. Over a 13-year development and construction period, the company built 30 tanks and never experienced a failure. Now, after years of additional development, an advanced version of 3D is finding application as part of a containment system for transporting Liquefied Natural Gas (LNG) by ship.

  16. Study of thermal conductivity of multilayer insulation

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, D; Sundaram, S; Nath, G K; Sethuram, N P; Chandrasekharan, T; Varadarajan, T G [Heavy Water Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    This paper presents experimental determination of the apparent thermal conductivity of multilayer insulation for a cryogenic system. The variation of thermal conductivity with residual gas pressure is studied and the optimum vacuum for good insulating performance is determined. Evaporation loss technique for heat-inleak determination is employed. (author). 3 refs., 3 figs.

  17. Quality labels for retrofit cavity wall insulation : a comparative analysis

    NARCIS (Netherlands)

    Rovers, Twan Johannes Hendrikus; Entrop, Alexis Gerardus; Halman, Johannes I.M.

    2017-01-01

    Retrofit cavity wall insulation can be exerted to reduce the energy use for space heating and cooling of existing buildings. In multiple countries, quality labels have emerged for this insulation service. In this research project, an evaluation framework for cavity wall insulation is developed by

  18. ONLINE TECHNOLOGICAL MONITORING OF INSULATION DEFECTS IN ENAMELED WIRES

    Directory of Open Access Journals (Sweden)

    V. M. Zolotaryov

    2017-08-01

    Full Text Available In this paper the authors used non-destructive technological monitoring of defects insulation enameled wire with poliimid polymer. The paper is devoted to the statistical method for processing, comparison and analysis of results of measurements of parameters of insulation of enameled wire because of mathematical model of trend for application in active technological monitoring is developed; the recommendations for parameters of such monitoring are used. It is theoretically justified and the possibility of determination of dependence of the error on the velocity of movement of a wire for want of quantifying of defects in enameled insulation by non-destructive tests by high voltage. The dependence of average value of amount of defects for enameled wire with two-sheeted poliimid insulation in a range of nominal diameter 0.56 mm is experimentally determined. The technological monitoring purpose is to reduce the quantifying defects of enameled insulation.

  19. The White ceiling heuristic and the underestimation of Asian-American income.

    Science.gov (United States)

    Martin, Chris C; Nezlek, John B

    2014-01-01

    The belief that ethnic majorities dominate ethnic minorities informs research on intergroup processes. This belief can lead to the social heuristic that the ethnic majority sets an upper limit that minority groups cannot surpass, but this possibility has not received much attention. In three studies of perceived income, we examined how this heuristic, which we term the White ceiling heuristic leads people to inaccurately estimate the income of a minority group that surpasses the majority. We found that Asian Americans, whose median income has surpassed White median income for nearly three decades, are still perceived as making less than Whites, with the least accurate estimations being made by people who strongly believe that Whites are privileged. In contrast, income estimates for other minorities were fairly accurate. Thus, perceptions of minorities are shaped both by stereotype content and a heuristic.

  20. Thermal insulation coating based on water-based polymer dispersion

    Directory of Open Access Journals (Sweden)

    Panchenko Iuliia

    2018-01-01

    Full Text Available For Russia, due to its long winter period, improvement of thermal insulation properties of envelope structures by applying thermal insulation paint and varnish coating to its inner surface is considered perspective. Thermal insulation properties of such coatings are provided by adding aluminosilicate microspheres and aluminum pigment to their composition. This study was focused on defining the effect of hollow aluminosilicate microspheres and aluminum pigment on the paint thermal insulation coating based on water-based polymer dispersion and on its optimum filling ratio. The optimum filling ratio was determined using the method of critical pigment volume concentration (CPVC. The optimum filling ratio was found equal to 55%.

  1. Navigating the Labyrinth

    Science.gov (United States)

    Eagly, Alice H.; Carli, Linda L.

    2009-01-01

    The glass ceiling has shattered. The metaphor of a glass ceiling, an absolute barrier to women's advancement, is seriously outdated. Some women do make it to high positions as big-city superintendents of schools, governors, secretaries of state and, even occasionally, as Fortune 500 CEOs. The glass ceiling metaphor has great appeal but is…

  2. Testing of ITER central solenoid coil insulation in an array

    International Nuclear Information System (INIS)

    Jayakumar, R.; Martovetsky, N.N.; Perfect, S.A.

    1995-01-01

    A glass-polyimide insulation system has been proposed by the US team for use in the Central Solenoid (CS) coil of the international Thermonuclear Experimental Reactor (ITER) machine and it is planned to use this system in the CS model coil inner module. The turn insulation will consist of 2 layers of combined prepreg and Kapton. Each layer is 50% overlapped with a butt wrap of prepreg and an overwrap of S glass. The coil layers will be separated by a glass-resin composite and impregnated in a VPI process. Small scale tests on the various components of the insulation are complete. It is planned to fabricate and test the insulation in a 4 x 4 insulated CS conductor array which will include the layer insulation and be vacuum impregnated. The conductor array will be subjected to 20 thermal cycles and 100000 mechanical load cycles in a Liquid Nitrogen environment. These loads are similar to those seen in the CS coil design. The insulation will be electrically tested at several stages during mechanical testing. This paper will describe the array configuration, fabrication: process, instrumentation, testing configuration, and supporting analyses used in selecting the array and test configurations

  3. Post-Insulation of Existing Buildings Constructed Between 1850 and 1920

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2010-01-01

    as a result of post-insulation measures. Besides lower heating costs and reduced CO2 emissions, improvement of the insulation standard could contribute to the elimination of other aspects of discomfort, such as draught originating from cold surfaces inside. This paper considers post-insulation of a simulated...

  4. Supporting documentation for the 1997 revision to the DOE Insulation Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, T.K.

    1997-08-22

    The Department of Energy (DOE) Insulation Fact Sheet has been revised to reflect developments in energy conservation technology and the insulation market. A nationwide insulation cost survey was made by polling insulation contractors and builders, and the results are reported here. These costs, along with regional weather data, regional fuel costs, and fuel-specific system efficiencies were used to produce recommended insulation levels for new and existing houses. This report contains all of the methodology, algorithms, assumptions, references, and data resources that were used to produce the 1997 DOE Insulation Fact Sheet.

  5. Design and analysis of the PBFA-Z vacuum insulator stack

    International Nuclear Information System (INIS)

    Shoup, R.W.; Long, F.; Martin, T.H.; Stygar, W.A.; Spielman, R.B.; Struve, K.W.; Mostrom, M.; Corcoran, P.; Smith, I.

    1996-01-01

    Sandia is developing PBFA-Z, a 20-MA driver for z-pinch experiments by replacing the water lines, insulator stack, and MITLs on PBFA II with new hardware. The design of the vacuum insulator stack was dictated by the drive voltage, the electric field stress and grading requirements, the water line and MITL interface requirements, and the machine operations and maintenance requirements. The insulator stack will consist of four separate modules, each of a different design because of different voltage drive and hardware interface requirements. The shape of the components in each module, i.e., grading rings, insulator rings, flux excluders, anode and cathode conductors, and the design of the water line and MITL interfaces, were optimized by using the electrostatic analysis codes, ELECTRO and JASON. The time-dependent performance of the insulator stack was evaluated using IVORY, a 2-D PIC code. The insulator stack design and present the results of the ELECTRO and IVORY analyses are described. (author). 2 tabs., 9 figs., 3 refs

  6. The topological Anderson insulator phase in the Kane-Mele model

    Science.gov (United States)

    Orth, Christoph P.; Sekera, Tibor; Bruder, Christoph; Schmidt, Thomas L.

    2016-04-01

    It has been proposed that adding disorder to a topologically trivial mercury telluride/cadmium telluride (HgTe/CdTe) quantum well can induce a transition to a topologically nontrivial state. The resulting state was termed topological Anderson insulator and was found in computer simulations of the Bernevig-Hughes-Zhang model. Here, we show that the topological Anderson insulator is a more universal phenomenon and also appears in the Kane-Mele model of topological insulators on a honeycomb lattice. We numerically investigate the interplay of the relevant parameters, and establish the parameter range in which the topological Anderson insulator exists. A staggered sublattice potential turns out to be a necessary condition for the transition to the topological Anderson insulator. For weak enough disorder, a calculation based on the lowest-order Born approximation reproduces quantitatively the numerical data. Our results thus considerably increase the number of candidate materials for the topological Anderson insulator phase.

  7. Design and analysis of the PBFA-Z vacuum insulator stack

    Energy Technology Data Exchange (ETDEWEB)

    Shoup, R W [Field Command Defense Nuclear Agency, Kirtland AFB, NM (United States); Long, F; Martin, T H; Stygar, W A; Spielman, R B [Sandia National Laboratories, Albuquerque, NM (United States). Dept 9573; Ives, H [EG and G, Albuquerque, NM (United States); Struve, K W; Mostrom, M [Mission Research Corp., Albuquerque, NM (United States); Corcoran, P; Smith, I [Pulse Sciences, Inc., San Leandro, CA (United States)

    1997-12-31

    Sandia is developing PBFA-Z, a 20-MA driver for z-pinch experiments by replacing the water lines, insulator stack, and MITLs on PBFA II with new hardware. The design of the vacuum insulator stack was dictated by the drive voltage, the electric field stress and grading requirements, the water line and MITL interface requirements, and the machine operations and maintenance requirements. The insulator stack will consist of four separate modules, each of a different design because of different voltage drive and hardware interface requirements. The shape of the components in each module, i.e., grading rings, insulator rings, flux excluders, anode and cathode conductors, and the design of the water line and MITL interfaces, were optimized by using the electrostatic analysis codes, ELECTRO and JASON. The time-dependent performance of the insulator stack was evaluated using IVORY, a 2-D PIC code. The insulator stack design and present the results of the ELECTRO and IVORY analyses are described. (author). 2 tabs., 9 figs., 3 refs.

  8. Effect of wind on Svalbard reindeer fur insulation

    Directory of Open Access Journals (Sweden)

    Christine Cuyler

    2002-06-01

    Full Text Available The heat transfer through Svalbard reindeer (Rangifer tarandus platyrhynchus fur samples was studied with respect to wind velocity, season and animal age. A total of 33 dorsal fur sections were investigated using a wind tunnel. Insulation varied with season (calving, summer, autumn and winter. At zero wind velocity, fur insulation was significantly different between seasons for both calf and adult fur samples. At the same time, there was no significant difference between calf and adult insulation for the summer, autumn and winter seasons. Calf fur insulated as well as adult fur. Winter insulation of Svalbard reindeer was approximately 3 times that of summer. Increasing wind veloci¬ty increased heat loss, however, the increase was not dramatic. When wind coefficients (slope of the heat transfer regression lines were compared, between season and between calf and adult, no significant differences were reported. All fur samples showed similar increases in heat transfer for wind velocities between 0 and 10 m.s-1. The conductance of winter fur of Svalbard reindeer was almost half that of caribou fur. Also, conductance was not as greatly influenced by wind as caribou fur

  9. Physical processes in high field insulating liquid conduction

    Science.gov (United States)

    Mazarakis, Michael; Kiefer, Mark; Leckbee, Joshua; Anderson, Delmar; Wilkins, Frank; Obregon, Robert

    2017-10-01

    In the power grid transmission where a large amount of energy is transmitted to long distances, High Voltage DC (HVDC) transmission of up to 1MV becomes more attractive since is more efficient than the counterpart AC. However, two of the most difficult problems to solve are the cable connections to the high voltage power sources and their insulation from the ground. The insulating systems are usually composed of transformer oil and solid insulators. The oil behavior under HVDC is similar to that of a weak electrolyte. Its behavior under HVDC is dominated more by conductivity than dielectric constant. Space charge effects in the oil bulk near high voltage electrodes and impeded plastic insulators affect the voltage oil hold-off. We have constructed an experimental facility where we study the oil and plastic insulator behavior in an actual HVDC System. Experimental results will be presented and compared with the present understanding of the physics governing the oil behavior under very high electrical stresses. Sandia National Laboratories managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. D.O.E., NNSA under contract DE-NA-0003525.

  10. Compact vacuum insulation embodiments

    Science.gov (United States)

    Benson, D.K.; Potter, T.F.

    1992-04-28

    An ultra-thin compact vacuum insulation panel is comprised of two hard, but bendable metal wall sheets closely spaced apart from each other and welded around the edges to enclose a vacuum chamber. Glass or ceramic spacers hold the wall sheets apart. The spacers can be discrete spherical beads or monolithic sheets of glass or ceramic webs with nodules protruding therefrom to form essentially point' or line' contacts with the metal wall sheets. In the case of monolithic spacers that form line' contacts, two such spacers with the line contacts running perpendicular to each other form effectively point' contacts at the intersections. Corrugations accommodate bending and expansion, tubular insulated pipes and conduits, and preferred applications are also included. 26 figs.

  11. Boson localization and the superfluid-insulator transition

    International Nuclear Information System (INIS)

    Fisher, M.P.A.; Weichman, P.B.; Grinstein, G.; Fisher, D.S.; Condensed Matter Physics 114-36, California Institute of Technology, Pasadena, California 91125; IBM Research Division, Thomas J. Watson Research Center, Yorktown Heights, New York 10598; Joseph Henry Laboratory of Physics, Jadwin Hall, Princeton University, Princeton, New Jersey 08544)

    1989-01-01

    The phase diagrams and phase transitions of bosons with short-ranged repulsive interactions moving in periodic and/or random external potentials at zero temperature are investigated with emphasis on the superfluid-insulator transition induced by varying a parameter such as the density. Bosons in periodic potentials (e.g., on a lattice) at T=0 exhibit two types of phases: a superfluid phase and Mott insulating phases characterized by integer (or commensurate) boson densities, by the existence of a gap for particle-hole excitations, and by zero compressibility. Generically, the superfluid onset transition in d dimensions from a Mott insulator to superfluidity is ''ideal,'' or mean field in character, but at special multicritical points with particle-hole symmetry it is in the universality class of the (d+1)-dimensional XY model. In the presence of disorder, a third, ''Bose glass'' phase exists. This phase is insulating because of the localization effects of the randomness and analogous to the Fermi glass phase of interacting fermions in a strongly disordered potential

  12. Interfacial Coatings for Inorganic Composite Insulation Systems

    International Nuclear Information System (INIS)

    Hooker, M. W.; Fabian, P. E.; Stewart, M. W.; Grandlienard, S. D.; Kano, K. S.

    2006-01-01

    Inorganic (ceramic) insulation materials are known to have good radiation resistance and desirable electrical and mechanical properties at cryogenic and elevated temperatures. In addition, ceramic materials can withstand the high-temperature reaction cycle used with Nb3Sn superconductor materials, allowing the insulation to be co-processed with the superconductor in a wind-and-react fabrication process. A critical aspect in the manufacture of ceramic-based insulation systems is the deposition of suitable fiber-coating materials that prevent chemical reaction of the fiber and matrix materials, and thus provide a compliant interface between the fiber and matrix, which minimizes the impact of brittle failure of the ceramic matrix. Ceramic insulation produced with CTD-FI-202 fiber interfaces have been found to exhibit very high shear and compressive strengths. However, this material is costly to produce. Thus, the goal of the present work is to evaluate alternative, lower-cost materials and processes. A variety of oxide and polyimide coatings were evaluated, and one commercially available polyimide coating has been shown to provide some improvement as compared to uncoated and de-sized S2 glass

  13. Experimental research on the indoor temperature and humidity fields in radiant ceiling air-conditioning system under natural ventilation

    Science.gov (United States)

    Huang, Tao; Xiang, Yutong; Wang, Yonghong

    2017-05-01

    In this paper, the indoor temperature and humidity fields of the air in a metal ceiling radiant panel air conditioning system with fresh air under natural ventilation were researched. The temperature and humidity distributions at different height and different position were compared. Through the computation analysis of partial pressure of water vapor, the self-recovery characteristics of humidity after the natural ventilation was discussed.

  14. The influence of the thermo-phono-insulating glazing structure configuration of some PVC profile windows on the airborne sound insulation – case study

    Directory of Open Access Journals (Sweden)

    Marta Cristina ZAHARIA

    2012-12-01

    Full Text Available After conducting laboratory acoustic measurements of airborne sound insulation for several windows with the same type of PVC profiles, equipped with different types of phono- and thermal - insulating glazings, the influence of the window’s glazed part (glass structure configuration on airborne sound insulation was analyzed. The configuration of the structure’s glazed part requires its composition of glass sheets with different thicknesses or intermediate layers of air with different thicknesses. This configuration has an important influence on the acoustic response of windows, namely on the index of air noise sound insulation, Rw, and on the behavior of the entire measurement frequency range.

  15. Aerogel-Based Insulation for Industrial Steam Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    John Williams

    2011-03-30

    Thermal losses in industrial steam distribution systems account for 977 trillion Btu/year in the US, more than 1% of total domestic energy consumption. Aspen Aerogels worked with Department of Energy’s Industrial Technologies Program to specify, develop, scale-up, demonstrate, and deliver Pyrogel XT®, an aerogel-based pipe insulation, to market to reduce energy losses in industrial steam systems. The product developed has become Aspen’s best selling flexible aerogel blanket insulation and has led to over 60 new jobs. Additionally, this product has delivered more than ~0.7 TBTU of domestic energy savings to date, and could produce annual energy savings of 149 TBTU by 2030. Pyrogel XT’s commercial success has been driven by it’s 2-4X better thermal performance, improved durability, greater resistance to corrosion under insulation (CUI), and faster installation times than incumbent insulation materials.

  16. Airborne sound insulation of new composite wall structures

    Directory of Open Access Journals (Sweden)

    Ivanova Yonka

    2018-01-01

    Full Text Available Protection against noise is one of the essential requirements of the European Construction Product directive. In buildings, airborne sound insulation is used to define the acoustical quality between rooms. In order to develop wall structures with optimal sound insulation, an understanding of the physical origins of sound transmission is necessary. To develop a kind of knowledge that is applicable to the improvement of real walls and room barriers is the motive behind this study. The purpose of the work is to study the sound insulation of new composite wall structure.

  17. Structure, Mechanism, and Application of Vacuum Insulation Panels in Chinese Buildings

    Directory of Open Access Journals (Sweden)

    Changhai Peng

    2016-01-01

    Full Text Available Thermal insulation is one of the most used approaches to reduce energy consumption in buildings. Vacuum insulation panels (VIPs are new thermal insulation materials that have been used in the domestic and overseas market in the last 20 years. Due to the vacuum thermal insulation technology of these new materials, their thermal conductivity can be as low as 0.004 W/(m·K at the center of panels. In addition, VIPs that are composites with inorganic core and an envelope out of commonly three metallized PET layers and a PE sealing layer can provide B class fire resistance (their core materials are not flammable and are classified as A1. Compared with other conventional thermal insulation materials, the thermal insulation and fire resistance performances form the foundation of VIP’s applications in the construction industry. The structure and thermal insulation mechanism of VIP and their application potential and problems in Chinese buildings are described in detail.

  18. Thermal Insulation System for Non-Vacuum Applications Including a Multilayer Composite

    Science.gov (United States)

    Fesmire, James E. (Inventor)

    2017-01-01

    The thermal insulation system of the present invention is for non-vacuum applications and is specifically tailored to the ambient pressure environment with any level of humidity or moisture. The thermal insulation system includes a multilayered composite including i) at least one thermal insulation layer and at least one compressible barrier layer provided as alternating, successive layers, and ii) at least one reflective film provided on at least one surface of the thermal insulation layer and/or said compressible barrier layer. The different layers and materials and their combinations are designed to provide low effective thermal conductivity for the system by managing all modes of heat transfer. The thermal insulation system includes an optional outer casing surrounding the multilayered composite. The thermal insulation system is particularly suited for use in any sub-ambient temperature environment where moisture or its adverse effects are a concern. The thermal insulation system provides physical resilience against damaging mechanical effects including compression, flexure, impact, vibration, and thermal expansion/contraction.

  19. Correlation among ESDD, NSDD and leakage current in distribution insulators

    International Nuclear Information System (INIS)

    Montoya, G.; Ramirez, I.; Montoya, J.I.

    2004-01-01

    The maintenance of distribution networks is more effective if the insulation contamination levels are known. The selection of measuring methods of pollution levels is then crucial. The relationship between several evaluation methods of pollution levels and the operating behaviour of several insulator profiles in a polluted zone is described. Laboratory tests were carried out to reproduce pollution levels found in the field. The quantity of non-soluble materials deposited over the insulators' surface affect the magnitude of the leakage current generated over a contaminated insulator. The relationship that defines leakage current with respect to the equivalent salt deposit density (ESDD) level for a specific non-soluble material level is almost linear, from which it is possible to develop a relationship between them for each insulator. (author)

  20. Sustainability assessment of a lightweight biomimetic ceiling structure

    International Nuclear Information System (INIS)

    Antony, Florian; Speck, Thomas; Speck, Olga; Grießhammer, Rainer

    2014-01-01

    An intensive and continuous debate centres on the question of whether biomimetics has a specific potential to contribute to sustainability. In the context of a case study, the objective of this paper is to contribute to this debate by presenting the first systematic approach to assess the sustainability of a complex biomimetic product. The object of inquiry is a lecture hall's ribbed slab. Based on criteria suggested by the Association of German Engineers (VDI), it has been verified that the slab has been correctly defined as biomimetic. Moreover, a systematic comparative product sustainability assessment has been carefully carried out. For purposes of comparison, estimated static calculations have been performed for conceivable current state-of-the-art lightweight ceiling structures. Alternative options are a hollow article slab and a pre-stressed flat slab. Besides a detailed benefit analysis and a discussion of social effects, their costs have also been compared. A particularly detailed life cycle assessment on the respective environmental impacts has also been performed. Results show that the biomimetic ribbed slab built in the 1960s is able to keep up with the current state-of-the-art lightweight solutions in terms of sustainability. These promising results encourage a systematic search for a broad range of sustainable biomimetic solutions. (paper)