WorldWideScience

Sample records for scattering monochromatic x-ray

  1. Monochromatic Mammographic Imaging Using X-ray Polycapillary Optics

    National Research Council Canada - National Science Library

    Sugiro, Francisca

    2000-01-01

    .... Monochromatic x rays can be used to produce higher contrast images. Polycapillary x-ray optics technology can produce a highly parallel, monochromatic, x-ray beam from a conventional radiographic source...

  2. Monochromatic Mammographic Imaging Using X-Ray Polycapillary Optics

    National Research Council Canada - National Science Library

    Sugiro, Francisca

    2002-01-01

    .... However, conventionaI laboratory sources normally have insufficient intensity. Polycapillary x-ray optics can be used to efficiently produce an intense parallel beam, which can be diffracted from a crystal to create monochromatic radiation...

  3. Fluor'X: a near monochromatic x-ray source

    Science.gov (United States)

    Marfeld, Jan; van Dorssen, Gert E.; Niestadt, Marcel

    2001-12-01

    More than 100 years after the discovery of X-rays by Roentgen the basic design of X-ray tubes remains nearly unchanged. A polychromatic spectrum of X-rays is generated by deceleration of electrons in a heavy (metal) target, superimposed by the characteristic fluorescence lines of that material. Nowadays, in many applications the need for near monochromatic radiation is beneficial or even mandatory. In this paper an X-ray tube is described which emits a spectrum consisting only of characteristic fluorescence radiation. Measurements of the yield and spectral distribution are presented, as well as possible applications.

  4. Advantages of quasi-monochromatic X-ray sources in absorption mammography

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, P. [Universita di Sassari, INFN Cagliari (Italy)], E-mail: oliva@df.unipi.it; Golosio, B.; Stumbo, S.; Carpinelli, M. [Universita di Sassari, INFN Cagliari (Italy)

    2009-09-01

    Mammography is a challenging field of medical imaging. Early detection of breast cancer requires identifying small contrast details. The choice of the appropriate monochromatic energy enhances the visibility of such details. Thomson scattering source can provide tunable quasi-monochromatic X-ray beams. In this work, we investigate by Monte Carlo simulations the optimal monochromatic energy to image mammographic phantoms. In order to mimic a Thomson scattering source, we consider the effect on image quality of the presence of an energy spread and of the presence of higher-order harmonics.

  5. Monochromatic plasma x-ray generator and its applications

    Science.gov (United States)

    Sato, Eiichi; Sagae, Michiaki; Takahashi, Kei; Ichimaru, Toshio; Aiba, Wataru; Kumagai, Shigehito; Hayasi, Yasuomi; Ido, Hideaki; Sakamaki, Kimio; Takayama, Kazuyoshi; Tamakawa, Yoshiharu

    1998-07-01

    The constructions of a plasma flash x-ray generator having a cold-cathode radiation tube and its application to soft radiography are described. The x-ray generator employs a high- voltage power supply, a low-impedance coaxial transmission line with a gap switch, a high-voltage condenser with a capacity of 0.2 (mu) F, a turbo-molecular pump, a thyristor pulser as a trigger device, and a flash x-ray tube. The high- voltage main condenser is charged up to 60 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The flash x-rays are then produced. The x-ray tube is a demountable triode which is connected to the turbo molecular pump with a pressure of approximately 1 mPa. This tube consists of a rod-shaped carbon cathode, a trigger electrode made from a copper wire, a stainless-steel vacuum chamber, insulators, a polyethylene terephthalate x-ray window, and two anode electrodes (targets) of molybdenum and silver. The space between the anode and cathode electrodes had a constant value of approximately 20 mm, and the trigger electrode is set in the center of the cathode electrode. As the electron flows from the cathode electrode are roughly converged to the target by the electric field in the tube, the plasma x-ray source which consists of metal ions and electrons is produced by the target evaporating. Because the bremsstrahlung spectra are absorbed by the monochromatic filter, K-series characteristic x-rays are obtained. Both the tube voltage and current displayed damped oscillations, and their peak values increased according to increases in the charging voltage. In the present work, the peak tube voltage was almost equivalent to the initial charging voltage of the main condenser, and the peak current had a value of about 25 kA with a charging voltage of 60 kV. When the charging voltage was increased, the intensities of the K-series characteristic x-rays increased. Next, the intensities

  6. Dual Energy X-Ray CT by Compton Scattering Hard X-Ray Source

    CERN Document Server

    Uesaka, Mitsuru; Kaneyasu, Tatsuo; Torikoshi, Masami

    2005-01-01

    We have developed a compact Compton scattering hard X-ray source at Nuclear Engineering Research Laboratory, University of Tokyo. The compact hard X-ray source can produce tunable monochromatic hard X-rays. The monochromatic hard X-rays are required in large field of medical and biological applications. We are planning to perform dual-energy X-ray CT, which enables us to measure atomic number Z distribution and electron density re distribution in a material. The hard X-ray source has an advantage to perform dual-energy X-ray CT. The X-ray energy can be changed quickly by introducing a fundamental frequency and a second harmonic frequency lasers. This quick energy change is indispensable to medical imaging and very difficult in a large SR light source and others. The information on the atomic number and electron density will be used for treatment plan in radiotherapy as well as for identification of materials in a nondestructive test. We examined applicability of the dual-energy X-ray CT for atomic number meas...

  7. High power laser pulse circulation experiment for compact quasi-monochromatic tunable X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Meng, De [Nuclear Professional School, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan)]. E-mail: dmou@nuclear.jp; Sakamoto, Fumito [Nuclear Professional School, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Yamamoto, Tomohiko [Nuclear Professional School, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Dobashi, Katsuhiro [Nuclear Professional School, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Uesaka, Mitsuru [Nuclear Professional School, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Nose, Hiroyuki [Ishikawajima-Harima Heavy Industries Co., Ltd., Toyosu Ihi Building, 1-1, Toyosu 3-chome, Koto-ku, Tokyo 135-8710 (Japan); Ishida, Daisuke [Ishikawajima-Harima Heavy Industries Co., Ltd., Toyosu Ihi Building, 1-1, Toyosu 3-chome, Koto-ku, Tokyo 135-8710 (Japan); Kaneko, Namio [Ishikawajima-Harima Heavy Industries Co., Ltd., Toyosu Ihi Building, 1-1, Toyosu 3-chome, Koto-ku, Tokyo 135-8710 (Japan); Sakai, Yasuo [Ishikawajima-Harima Heavy Industries Co., Ltd., Toyosu Ihi Building, 1-1, Toyosu 3-chome, Koto-ku, Tokyo 135-8710 (Japan)

    2007-08-15

    Laser electron Compton scattering monochromatic tunable X-ray source using X-band (11.424 GHz) electron linear accelerator and Q-switch Nd:YAG laser is under construction at Nuclear Professional School, University of Tokyo. To enhance the X-ray intensity, we installed a laser circulation system. Now, we are performing the circulation experiment by using a high power laser (1.4 J, 532 nm). We confirmed the laser pulse circulated in the optical circuit more than 15 times and the laser intensity is enhanced about 3.5 times.

  8. High resolution, monochromatic x-ray topography capability at CHESS

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, K. D., E-mail: kdf1@cornell.edu; Pauling, A.; Brown, Z. [CHESS, Cornell University, Ithaca, NY (United States); Jones, R. [Department of Physics, University of Connecticut, Storrs, CT (United States); Tarun, A.; Misra, D. S. [IIa Technologies (Singapore); Jupitz, S. [St. Mary’s College of Maryland, St. Mary’s City, MD (United States); Sagan, D. C. [CLASSE, Cornell University, Ithaca, NY (United States)

    2016-07-27

    CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

  9. Broadband, monochromatic and quasi-monochromatic x-ray propagation in multi-Z media for imaging and diagnostics

    Science.gov (United States)

    Westphal, Maximillian S.; Lim, Sara N.; Nahar, Sultana N.; Chowdhury, Enam; Pradhan, Anil K.

    2017-08-01

    With the advent of monochromatic and quasi-monochromatic x-ray sources, we explore their potential with computational and experimental studies on propagation through a combination of low and high-Z (atomic number) media for applications to imaging and detection. The multi-purpose code GEANT4 and a new code PHOTX are employed in numerical simulations, and a variety of x-ray sources are considered: conventional broadband devices with well-known spectra, quasi-monochromatic laser driven sources, and monochromatic synchrotron x-rays. Phantom samples consisting of layers of low-Z and high-Z material are utilized, with atomic-molecular species ranging from H2O to gold. Differential and total attenuation of x-ray fluxes from the different x-ray sources are illustrated through simulated x-ray images. Main conclusions of this study are: I. It is shown that a 65 keV Gaussian quasi-monochromatic source is capable of better contrast with less radiation exposure than a common 120 kV broadband simulator. II. A quantitative measure is defined and computed as a metric to compare the efficacy of any two x-ray sources, as a function of concentration of high-Z moieties in predominantly low-Z environment and depth of penetration. III. Characteristic spectral features of \

  10. Beam collimation with polycapillary x-ray optics for high contrast high resolution monochromatic imaging.

    Science.gov (United States)

    Sugiro, Francisca R; Li, Danhong; MacDonald, C A

    2004-12-01

    Monochromatic imaging can provide better contrast and resolution than conventional broadband radiography. In broadband systems, low energy photons do not contribute to the image, but are merely absorbed, while high energy photons produce scattering that degrades the image. By tuning to the optimal energy, one can eliminate undesirable lower and higher energies. Monochromatization is achieved by diffraction from a single crystal. A crystal oriented to diffract at a particular energy, in this case the characteristic line energy, diffracts only those photons within a narrow range of angles. The resultant beam from a divergent source is nearly parallel, but not very intense. To increase the intensity, collimation was performed with polycapillary x-ray optics, which can collect radiation from a divergent source and redirect it into a quasi parallel beam. Contrast and resolution measurements were performed with diffracting crystals with both high and low angular acceptance. Testing was first done at 8 keV with an intense copper rotating anode x-ray source, then 17.5 keV measurements were made with a low power molybdenum source. At 8 keV, subject contrast was a factor of five higher than for the polychromatic case. At 17.5 keV, monochromatic contrast was two times greater than the conventional polychromatic contrast. The subject contrasts measured at both energies were in good agreement with theory. An additional factor of two increase in contrast, for a total gain of four, is expected at 17.5 keV from the removal of scatter. Scatter might be simply removed using an air gap, which does not degrade resolution with a parallel beam.

  11. Characteristics of a multi-keV monochromatic point x-ray source ...

    Indian Academy of Sciences (India)

    Temporal, spatial and spectral characteristics of a multi-keV monochromatic point x-ray source based on vacuum diode with laser-produced plasma as cathode are presented. Electrons from a laser-produced aluminium plasma were accelerated towards a conical point tip titanium anode to generate K-shell x-ray radiation.

  12. Grazing Incidence X-ray Scattering and Diffraction

    Indian Academy of Sciences (India)

    ... Journals; Resonance – Journal of Science Education; Volume 19; Issue 12. Grazing Incidence X-ray Scattering and Diffraction. Jaydeep K Basu. General Article Volume 19 Issue 12 December ... Keywords. X-ray reflectivity; X-ray diffuse scattering; grazing incident diffraction; grazing incident; small angle X-ray scattering.

  13. Monochromatic Mammographic Imaging Using X-Ray Polycapillary Optics

    National Research Council Canada - National Science Library

    Surgiro, Frannieoa

    2001-01-01

    .... The transmission is about 39% at 17.5 keV. The measurements agree quite well with simulations. Monochromatic imaging was performed using this optic with two different sources, a rotating anode copper source and a low power molybdenum source...

  14. Healing X-ray scattering images.

    Science.gov (United States)

    Liu, Jiliang; Lhermitte, Julien; Tian, Ye; Zhang, Zheng; Yu, Dantong; Yager, Kevin G

    2017-07-01

    X-ray scattering images contain numerous gaps and defects arising from detector limitations and experimental configuration. We present a method to heal X-ray scattering images, filling gaps in the data and removing defects in a physically meaningful manner. Unlike generic inpainting methods, this method is closely tuned to the expected structure of reciprocal-space data. In particular, we exploit statistical tests and symmetry analysis to identify the structure of an image; we then copy, average and interpolate measured data into gaps in a way that respects the identified structure and symmetry. Importantly, the underlying analysis methods provide useful characterization of structures present in the image, including the identification of diffuse versus sharp features, anisotropy and symmetry. The presented method leverages known characteristics of reciprocal space, enabling physically reasonable reconstruction even with large image gaps. The method will correspondingly fail for images that violate these underlying assumptions. The method assumes point symmetry and is thus applicable to small-angle X-ray scattering (SAXS) data, but only to a subset of wide-angle data. Our method succeeds in filling gaps and healing defects in experimental images, including extending data beyond the original detector borders.

  15. Healing X-ray scattering images

    Directory of Open Access Journals (Sweden)

    Jiliang Liu

    2017-07-01

    Full Text Available X-ray scattering images contain numerous gaps and defects arising from detector limitations and experimental configuration. We present a method to heal X-ray scattering images, filling gaps in the data and removing defects in a physically meaningful manner. Unlike generic inpainting methods, this method is closely tuned to the expected structure of reciprocal-space data. In particular, we exploit statistical tests and symmetry analysis to identify the structure of an image; we then copy, average and interpolate measured data into gaps in a way that respects the identified structure and symmetry. Importantly, the underlying analysis methods provide useful characterization of structures present in the image, including the identification of diffuse versus sharp features, anisotropy and symmetry. The presented method leverages known characteristics of reciprocal space, enabling physically reasonable reconstruction even with large image gaps. The method will correspondingly fail for images that violate these underlying assumptions. The method assumes point symmetry and is thus applicable to small-angle X-ray scattering (SAXS data, but only to a subset of wide-angle data. Our method succeeds in filling gaps and healing defects in experimental images, including extending data beyond the original detector borders.

  16. Improved resolution for soft-x-ray monochromatization using lamellar multilayer gratings

    NARCIS (Netherlands)

    van der Meer, R.; Krishnan, B.; Kozhevnikov, I.V.; de Boer, Meint J.; Vratzov, B.; Bastiaens, Hubertus M.J.; Huskens, Jurriaan; van der Wiel, Wilfred Gerard; Hegeman, P.E.; Brons, G.C.S.; Boller, Klaus J.; Bijkerk, Frederik; Morawe, Christian; Khounsary, Ali M.; Goto, Shunji

    2011-01-01

    Lamellar Multilayer Gratings (LMG) offer improved resolution for soft-x-ray (SXR) monochromatization, while maintaining a high reflection efficiency in comparison to conventional multilayer mirrors (MM). We previously used a Coupled-Waves Approach (CWA) to calculate SXR diffraction by LMGs and

  17. Detection limits for actinides in a monochromatic, wavelength-dispersive x-ray fluorescence instrument

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Michael L [Los Alamos National Laboratory; Havrilla, George J [Los Alamos National Laboratory

    2009-01-01

    Recent developments in x-ray optics have made it possible to examine the L x-rays of actinides using doubly-curved crystals in a bench-top device. A doubly-curved crystal (DCC) acts as a focusing monochromatic filter for polychromatic x-rays. A Monochromatic, Wavelength-Dispersive X-Ray Fluorescence (MWDXRF) instrument that uses DCCs to measure Cm and Pu in reprocessing plant liquors was proposed in 2007 by the authors at Los Alamos National Laboratory. A prototype design of this MWDXRF instrument was developed in collaboration with X-ray Optical Systems Inc. (XOS), of East Greenbush, New York. In the MWDXRF instrument, x-rays from a Rhodium-anode x-ray tube are passed through a primary DCC to produce a monochromatic beam of 20.2-keV photons. This beam is focused on a specimen that may contain actinides. The 20.2-keV interrogating beam is just above the L3 edge of Californium; each actinide (with Z = 90 to 98) present in the specimen emits characteristic L x-rays as the result of L3-shell vacancies. In the LANL-XOS prototype MWDXRf, these x-rays enter a secondary DCC optic that preferentially passes 14.961-keV photons, corresponding to the L-alpha-1 x-ray peak of Curium. In the present stage of experimentation, Curium-bearing specimens have not been analyzed with the prototype MWDXRF instrument. Surrogate materials for Curium include Rubidium, which has a K-beta-l x-ray at 14.961 keV, and Yttrium, which has a K-alpha-1 x-ray at 14.958 keV. In this paper, the lower limit of detection for Curium in the LANL-XOS prototype MWDXRF instrument is estimated. The basis for this estimate is described, including a description of computational models and benchmarking techniques used. Detection limits for other actinides are considered, as well as future safeguards applications for MWDXRF instrumentation.

  18. Monochromatic X-Ray Imaging by X pinches on the COBRA Accelerator

    Science.gov (United States)

    Douglass, J. D.; Hammer, D. A.; Pikuz, S. A.; Shelkovenko, T. A.

    2006-10-01

    The COBRA accelerator is a pulsed power generator capable of producing up to 1 MA current pulses with a typical rise time of 100 ns and pulse width of about 200 ns. Time-gated x-ray imaging is an important diagnostic for the study of imploding dense z-pinches. These plasmas must be studied on the nanosecond time scale, and they generally radiate strongly in the soft x-ray range. As such, they require short, intense x-ray sources to illuminate them. Monochromatic x-ray imaging using an X pinch is a way that has been used successfully in the past [1,2] to image single exploding wires and various static objects. Experiments have been performed to investigate x-ray source parameters for various materials and configurations. Of these materials aluminum (6.6343å) and zinc (9.815å) have the most potential for use as a monochromatic source on COBRA. Data presented includes x-ray spectra (˜1-10 å) along with source size estimates and results from initial imaging experiments. This research was supported by the Stewardship Sciences Academic Alliances program of the National Nuclear Security Administration under DOE Cooperative agreement DE-FC03-02NA00057. [1] S. A. Pikuz, et al., Rev. Sci. Instrum., 68, 740 (1997). [2] D. B. Sinars, et al., Phys. Plasmas 13, 042704 (2006).

  19. Multimodal x-ray scatter imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bunk, O; Menzel, A [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Bech, M; Pfeiffer, F [Department Physik (E17), Technische Universitaet Muenchen, James-Franck-Strausse, 85748 Garching (Germany); Jensen, T H; Feidenhans' l, R [Niels Bohr Institute, University of Copenhagen, 2100 Copenhagen (Denmark); Binderup, T [Rigshospitalet and Faculty of Health Science, University of Copenhagen, 2100 Copenhagen (Denmark)], E-mail: oliver.bunk@psi.ch

    2009-12-15

    We describe a small-angle x-ray scattering-based imaging technique that reveals the distribution and orientation of nano-scale structures over extended areas. By combining two measurement and analysis schemes, complementary structural information is available which renders the technique suitable for a broad range of applications, e.g. in materials science and bio-imaging. Through a combination of current techniques and on-line analysis schemes, measurements with a so far unprecedented combination of speed, dynamic range and point density became feasible. This is illustrated by data recorded for a section of a mouse soleus muscle visualizing fine muscle and Achilles tendon structures down to the 10 nm range over a 10 mm{sup 2} sample area.

  20. Resonant inelastic x-ray scattering studies of elementary excitations

    NARCIS (Netherlands)

    Ament, Lucas Johannes Peter (Luuk)

    2010-01-01

    Resonant Inelastic X-ray Scattering (RIXS) is an X-ray in, X-ray out technique that enables one to study the dispersion of excitations in solids. In this thesis, we investigated how various elementary excitations of transition metal oxides show up in RIXS spectra.

  1. Resonant x-ray scattering in correlated systems

    CERN Document Server

    Ishihara, Sumio

    2017-01-01

    The research and its outcomes presented here is devoted to the use of x-ray scattering to study correlated electron systems and magnetism. Different x-ray based methods are provided to analyze three dimensional electron systems and the structure of transition-metal oxides. Finally the observation of multipole orderings with x-ray diffraction is shown.

  2. Resonant X-ray scattering in correlated systems

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Youichi [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan). Inst. of Materials Structure Science; Ishihara, Sumio (ed.) [Tohoku Univ., Sendai, Miyagi (Japan). Dept. of Physics

    2017-03-01

    The research and its outcomes presented here is devoted to the use of X-ray scattering to study correlated electron systems and magnetism. Different X-ray based methods are provided to analyze three dimensional electron systems and the structure of transition-metal oxides. Finally the observation of multipole orderings with X-ray diffraction is shown.

  3. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    Energy Technology Data Exchange (ETDEWEB)

    Bloomer, Chris, E-mail: chris.bloomer@diamond.ac.uk; Rehm, Guenther; Dolbnya, Igor P. [Diamond Light Source Ltd, Oxfordshire (United Kingdom)

    2016-07-27

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

  4. Magnetic X-Ray Scattering with Synchrotron Radiation

    DEFF Research Database (Denmark)

    Moncton, D. E.; Gibbs, D.; Bohr, Jakob

    1986-01-01

    With the availability of high-brilliance synchrotron radiation from multiple wigglers, magnetic X-ray scattering has become a powerful new probe of magnetic structure and phase transitions. Similar to the well-established magnetic neutron scattering technique, magnetic X-ray scattering methods have...

  5. Monochromatic X-Ray Induced Novel Synthesis of Plasmonic Nanostructure for Photovoltaic Application

    Science.gov (United States)

    Bharti, Amardeep; Bhardwaj, Richa; Agrawal, Ashish K.; Goyal, Navdeep; Gautam, Sanjeev

    2016-04-01

    It has been universally delineated that the plasmonic metal nanoparticles can enhance the efficiency of photovoltaic cell by increasing the probability of energetic solar photons capturing phenomena using localized surface plasmonic resonance response. In this paper, we developed a novel in-situ simple approach to synthesize noble plasmonic silver nanoparticles (AgNP) from aqueous poly-vinyl-pyrrolidone solution of metal salt using radiolysis of water via synchrotron monochromatic X-ray irradiation without any chemical reducing agent. X-ray irradiation of water produces hydrated electrons , superoxide and atom radicals , which triggers the reaction and reduces metal salt. X-ray radiolysis based synthesis provides the control over the reaction and prevent the formation of secondary products as occurs in case of chemical reduction route. In the previous studies, synchrotron “white” X-rays had been examined for the synthesis of metal nanoparticles, but that technique limits only upto the material synthesis while in this work we explored the role of “monochromatic” X-rays for the production of bulk amount of nanoparticles which would also provide the feasibility of in-situ characterization. Transmission electron micrographs show that the synthesized AgNP appears spherical with diameter of 2-6 nm and is in agreement with the size estimation from uv-vis spectra by “Mie theory”.

  6. X-ray generation by inverse Compton scattering at the superconducting RF test facility

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Hirotaka, E-mail: hirotaka@post.kek.jp [KEK, 1-1 Oho, Tsukuba 305-0801, Ibaraki (Japan); Akemoto, Mitsuo; Arai, Yasuo; Araki, Sakae; Aryshev, Alexander; Fukuda, Masafumi; Fukuda, Shigeki; Haba, Junji; Hara, Kazufumi; Hayano, Hitoshi; Higashi, Yasuo; Honda, Yosuke; Honma, Teruya; Kako, Eiji; Kojima, Yuji; Kondo, Yoshinari; Lekomtsev, Konstantin; Matsumoto, Toshihiro; Michizono, Shinichiro; Miyoshi, Toshinobu [KEK, 1-1 Oho, Tsukuba 305-0801, Ibaraki (Japan); and others

    2015-02-01

    Quasi-monochromatic X-rays with high brightness have a broad range of applications in fields such as life sciences, bio-, medical applications, and microlithography. One method for generating such X-rays is via inverse Compton scattering (ICS). X-ray generation experiments using ICS were carried out at the superconducting RF test facility (STF) accelerator at KEK. A new beam line, newly developed four-mirror optical cavity system, and new X-ray detector system were prepared for experiments downstream section of the STF electron accelerator. Amplified pulsed photons were accumulated into a four-mirror optical cavity and collided with an incoming 40 MeV electron beam. The generated X-rays were detected using a microchannel plate (MCP) detector for X-ray yield measurements and a new silicon-on-insulator (SOI) detector system for energy measurements. The detected X-ray yield by the MCP detector was 1756.8±272.2 photons/(244 electron bunches). To extrapolate this result to 1 ms train length under 5 Hz operations, 4.60×10{sup 5} photons/1%-bandwidth were obtained. The peak X-ray energy, which was confirmed by the SOI detector, was 29 keV, and this is consistent with ICS X-rays.

  7. Resonance magnetic x-ray scattering study of erbium

    DEFF Research Database (Denmark)

    Sanyal, M.K.; Gibbs, D.; Bohr, J.

    1994-01-01

    The magnetic phases of erbium have been studied by resonance x-ray-scattering techniques. When the incident x-ray energy is tuned near the L(III) absorption edge, large resonant enhancements of the magnetic scattering are observed above 18 K. We have measured the energy and polarization dependence...

  8. Quantum effets in nonresonant X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Slowik, Jan Malte

    2015-11-15

    Due to their versatile properties, X rays are a unique tool to investigate the structure and dynamics of matter. X-ray scattering is the fundamental principle of many imaging techniques. Examples are X-ray crystallography, which recently celebrated one hundred years and is currently the leading method in structure determination of proteins, as well as X-ray phase contrast imaging (PCI), which is an imaging technique with countless applications in biology, medicine, etc. The technological development of X-ray free electron lasers (XFEL) has brought X-ray imaging at the edge of a new scientific revolution. XFELs offer ultrashort X-ray pulses with unprecedented high X-ray fluence and excellent spatial coherence properties. These properties make them an outstanding radiation source for X-ray scattering experiments, providing ultrafast temporal resolution as well as atomic spatial resolution. However, the radiation-matter interaction in XFEL experiments also advances into a novel regime. This demands a sound theoretical fundament to describe and explore the new experimental possibilities. This dissertation is dedicated to the theoretical study of nonresonant X-ray scattering. As the first topic, I consider the near-field imaging by propagation based X-ray phase contrast imaging (PCI). I devise a novel theory of PCI, in which radiation and matter are quantized. Remarkably, the crucial interference term automatically excludes contributions from inelastic scattering. This explains the success of the classical description thus far. The second topic of the thesis is the X-ray imaging of coherent electronic motion, where quantum effects become particularly apparent. The electron density of coherent electronic wave packets - important in charge transfer and bond breaking - varies in time, typically on femto- or attosecond time scales. In the near future, XFELs are envisaged to provide attosecond X-ray pulses, opening the possibility for time-resolved ultrafast X-ray scattering

  9. Quasi-Monochromatic Flash X-Ray Generator Utilizing Disk-Cathode Molybdenum Tube

    Science.gov (United States)

    Sato, Eiichi; Sagae, Michiaki; Tanaka, Etsuro; Hayasi, Yasuomi; Germer, Rudolf; Mori, Hidezo; Kawai, Toshiaki; Ichimaru, Toshio; Sato, Shigehiro; Takayama, Kazuyoshi; Ido, Hideaki

    2004-10-01

    High-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -40 to -60 kV using a power supply, and the electric charges in the condensers are discharged to an X-ray tube after closing the gap switches in the surge generator using a trigger device. The X-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Sharp K-series characteristic X-rays of molybdenum are produced without using a monochromatic filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. The peak tube voltage increased with increasing charging voltage and increasing space between the target and cathode electrodes. At a charging voltage of -60 kV and a target-cathode space of 1.0 mm, the peak tube voltage and current were 110 kV and 0.75 kA, respectively. The pulse width ranged from 40 to 100 ns, and the maximum dimension of the X-ray source was 3.0 mm in diameter. The number of generator-produced K photons was approximately 7× 1014 photons/cm2\\cdots at 0.5 m from the source.

  10. Imaging-therapy computed tomography with quasi-monochromatic X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: gregor.jost@bayerhealthcare.com; Golfier, Sven [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: sven.golfier@bayerhealthcare.com; Lawaczeck, Ruediger [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: ruediger.lawaczeck@bayerhealthcare.com; Weinmann, Hanns-Joachim [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: hanns-joachim.weinmann@bayerhealthcare.com; Gerlach, Martin [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: martin.gerlach@ptb.de; Cibik, Levent [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: levent.cibik@ptb.de; Krumrey, Michael [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: michael.krumrey@ptb.de; Fratzscher, Daniel [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Fratzscher@ifg-adlershof.de; Rabe, Johannis [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Rabe@ifg-adlershof.de; Arkadiev, Vladimir [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Arkadiev@ifg-adlershof.de; Haschke, Michael [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Haschke@ifg-adlershof.de; Langhoff, Norbert [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Langhoff@ifg-adlershof.de; Wedell, Reiner [Institut fuer angewandte Photonik e.V., Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: wedell-iap@ifg-adlershof.de (and others)

    2008-12-15

    Introduction: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. Materials and methods: The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. Results: The X-ray optical module filters selectively the energy of the tungsten K{alpha}-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. Conclusion: An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT.

  11. Density measurement of low- Z shocked material from monochromatic x-ray two-dimensional images.

    Science.gov (United States)

    Benuzzi-Mounaix, A; Loupias, B; Koenig, M; Ravasio, A; Ozaki, N; Rabec le Gloahec, M; Vinci, T; Aglitskiy, Y; Faenov, A; Pikuz, T; Boehly, T

    2008-04-01

    An experiment on LULI 2000 laser devoted to density determination of shocked plastic from a two-dimensional monochromatic x-ray radiography is presented. A spherical quartz crystal was set to select the He-alpha line of vanadium at 2.382 A and perform the image of the main target. Rear side diagnostics were implemented to validate the new diagnostic. The density experimental results given by radiography are in good agreement with rear side diagnostics data and hydrodynamical simulations. The pressure regime into the plastic is 2-3 Mbar, corresponding to a compression between 2.7-2.9.

  12. Heterodyne x-ray diffuse scattering from coherent phonons.

    Science.gov (United States)

    Kozina, M; Trigo, M; Chollet, M; Clark, J N; Glownia, J M; Gossard, A C; Henighan, T; Jiang, M P; Lu, H; Majumdar, A; Zhu, D; Reis, D A

    2017-09-01

    Here, we report Fourier-transform inelastic x-ray scattering measurements of photoexcited GaAs with embedded ErAs nanoparticles. We observe temporal oscillations in the x-ray scattering intensity, which we attribute to inelastic scattering from coherent acoustic phonons. Unlike in thermal equilibrium, where inelastic x-ray scattering is proportional to the phonon occupation, we show that the scattering is proportional to the phonon amplitude for coherent states. The wavevectors of the observed phonons extend beyond the excitation wavevector. The nanoparticles break the discrete translational symmetry of the lattice, enabling the generation of large wavevector coherent phonons. Elastic scattering of x-ray photons from the nanoparticles provides a reference for heterodyne mixing, yielding signals proportional to the phonon amplitude.

  13. X-Band Linac Beam-Line for Medical Compton Scattering X-Ray Source

    CERN Document Server

    Dobashi, Katsuhiro; Ebina, Futaro; Fukasawa, Atsushi; Hayano, Hitoshi; Higo, Toshiyasu; Kaneyasu, Tatsuo; Ogino, Haruyuki; Sakamoto, Fumito; Uesaka, Mitsuru; Urakawa, Junji; Yamamoto, Tomohiko

    2005-01-01

    Compton scattering hard X-ray source for 10~80 keV are under construction using the X-band (11.424 GHz) electron linear accelerator and YAG laser at Nuclear Engineering Research laboratory, University of Tokyo. This work is a part of the national project on the development of advanced compact medical accelerators in Japan. National Institute for Radiological Science is the host institute and U. Tokyo and KEK are working for the X-ray source. Main advantage is to produce tunable monochromatic hard ( 10-80

  14. X-Ray-Scattering Measurements Of Strain In PEEK

    Science.gov (United States)

    Cebe, Peggy; Lowry, Lynn E.; Chung, Shirley Y.; Yavrouian, Andre H.; Gupta, Amitava

    1988-01-01

    Internal stress relieved by heating above glass-transition temperature. Report describes wide-angle x-ray scattering and differential scanning calorimetry of specimens of poly(etheretherketone) having undergone various thermal treatments. Wide-angle x-ray scattering particularly useful in determining distances between atoms, crystallinity, and related microstructurally generated phenomena, as thermal expansion and strain. Calorimetric measurements aid interpretation of scattering measurements by enabling correlation with thermal effects.

  15. Morphology of nanocermet thin films: X-ray scattering study

    Science.gov (United States)

    Hazra, S.; Gibaud, A.; Désert, A.; Sella, C.; Naudon, A.

    2000-06-01

    The morphology of ceramic-metal (cermet) thin films is studied by surface-sensitive X-ray scattering techniques. Grazing incidence small angle X-ray scattering (GISAXS) experiments carried out at LURE with a 2D detector show that metal clusters of nanometer size, known as nanoparticles, are dispersed in the thin film. Analyses of the X-ray reflectivity along with the diffuse scattering allow to predict the formation of layers of nanoparticles along the growth direction of the films. The formation of such cumulative-disordered layers in one direction is likely to be related to the boundary condition in the reduced dimension.

  16. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan

    1992-01-01

    Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...... in a test quadrant of the telescope structure and from ASTRO-D foils held in a simple fixture. The X-ray data is compared with laser data and other surface structure data such as STM, atomic force microscopy (AFM), TEM, and electron micrography. The data obtained at Cu K-alpha(1), (8.05 keV) from all...

  17. Calculation of x-ray scattering patterns from nanocrystals at high x-ray intensity

    Directory of Open Access Journals (Sweden)

    Malik Muhammad Abdullah

    2016-09-01

    Full Text Available We present a generalized method to describe the x-ray scattering intensity of the Bragg spots in a diffraction pattern from nanocrystals exposed to intense x-ray pulses. Our method involves the subdivision of a crystal into smaller units. In order to calculate the dynamics within every unit, we employ a Monte-Carlo-molecular dynamics-ab-initio hybrid framework using real space periodic boundary conditions. By combining all the units, we simulate the diffraction pattern of a crystal larger than the transverse x-ray beam profile, a situation commonly encountered in femtosecond nanocrystallography experiments with focused x-ray free-electron laser radiation. Radiation damage is not spatially uniform and depends on the fluence associated with each specific region inside the crystal. To investigate the effects of uniform and non-uniform fluence distribution, we have used two different spatial beam profiles, Gaussian and flattop.

  18. Characterization of oil nano-structures with monochromatic x-ray micro-tomography

    Science.gov (United States)

    Asadchikov, Victor E.; Buzmakov, Alexey V.; Osadchaya, Anna S.; Zolotov, Denis A.; Rafailov, Michael K.

    2012-10-01

    Here we report work done toward detection and characterization of micro-and nano-structures in bitumen, including mineral particles-clay and sand as well as metal-organic micro-and nano-structures containing porphyrines. X-ray micro-tomograph with monochromatic radiation has been used for detection of the structures. In order to detect and characterize nano-and micro-structures tomograph's operational wavelength has been tuned to absorption wavelength of "chemical element of interest" X-ray spectrum: whatever it is Si or porphyrine-forming metals like V, Ni, Co. Contrast between X-ray absorption of micro-structures containing specific element and average bitumen's environment absorption provides a tool for measurement of element mass concentration as well as size and mass density distributions of micro-and nano structures not only on surface but in bitumen volume. Specifically the most interest is in measurement of vanadyl porphyrines and other metal containing chemicals in asphaltene micro-structures changing per asphalten concentration due to bitumen processing.

  19. Curved crystal x-ray optics for monochromatic imaging with a clinical source.

    Science.gov (United States)

    Bingölbali, Ayhan; MacDonald, C A

    2009-04-01

    Monochromatic x-ray imaging has been shown to increase contrast and reduce dose relative to conventional broadband imaging. However, clinical sources with very narrow energy bandwidth tend to have limited intensity and field of view. In this study, focused fan beam monochromatic radiation was obtained using doubly curved monochromator crystals. While these optics have been in use for microanalysis at synchrotron facilities for some time, this work is the first investigation of the potential application of curved crystal optics to clinical sources for medical imaging. The optics could be used with a variety of clinical sources for monochromatic slot scan imaging. The intensity was assessed and the resolution of the focused beam was measured using a knife-edge technique. A simulation model was developed and comparisons to the measured resolution were performed to verify the accuracy of the simulation to predict resolution for different conventional sources. A simple geometrical calculation was also developed. The measured, simulated, and calculated resolutions agreed well. Adequate resolution and intensity for mammography were predicted for appropriate source/optic combinations.

  20. Electron Dynamics by Inelastic X-Ray Scattering

    CERN Document Server

    Schülke, Winfried

    2007-01-01

    The book offers the first comprehensive review of experimental methods, theory, and successful applications of synchrotron radiation based inelastic X-ray scattering (IXS) spectroscopy, which enables the investigation of electron dynamics in condensed matter (correlated motion and excitation).

  1. Observing Solvation Dynamics with Simultaneous Femtosecond X-ray Emission Spectroscopy and X-ray Scattering

    DEFF Research Database (Denmark)

    Haldrup, Kristoffer; Gawelda, Wojciech; Abela, Rafael

    2016-01-01

    In liquid phase chemistry dynamic solute solvent interactions often govern the path, ultimate outcome, and efficiency of chemical reactions. These steps involve many-body movements on subpicosecond time scales and thus ultrafast structural tools capable of capturing both intramolecular electronic......, confirming previous ab initio molecular dynamics simulations. Structural changes in the aqueous solvent associated with density and temperature changes occur with similar to 1 ps time constants, characteristic for structural dynamics in water. This slower time scale of the solvent response allows us...... rearrangement of the solute with X-ray emission spectroscopy, thus establishing time zero for the ensuing X-ray diffuse scattering analysis. The simultaneously recorded X-ray diffuse scattering atterns reveal slower subpicosecond dynamics triggered by the intramolecular structural dynamics of the photoexcited...

  2. Coherent methods in X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Gorobtsov, Oleg

    2017-05-15

    X-ray radiation has been used to study structural properties of materials for more than a hundred years. Construction of extremely coherent and bright X-ray radiation sources such as free electron lasers (FELs) and latest generationstorage rings led to rapid development of experimental methods relying on high radiation coherence. These methods allow to perform revolutionary studies in a wide range of fields from solid state physics to biology. In this thesis I focus on several important problems connected with the coherent methods. The first part considers applications of dynamical diffraction theory on crystals to studies with coherent X-ray radiation. It presents the design of a high-resolution spectrometer for free electron lasers that should allow to resolve spectral structure of individual FEL pulses. The spectrometer is based on the principle of dynamical diffraction focusing. The knowledge of individual FEL pulse spectra is necessary for understanding FEL longitudinal coherence. In the same part I present quasi-kinematical approximation to dynamical theory which allows to treat analytically phase effects observed in X-ray coherent imaging on nanocrystals. These effects may play a big role when methods such as ptychography are used to study crystalline samples. The second part deals with measurements of FEL coherence properties using intensity - intensity interferometry. Results of several experiments performed at FELs FLASH and LCLS are revealed in this section. I have developed models and theories to explain the behavior observed in experiments on FLASH. These models allowed to extract information about external positional jitter of FEL pulses and secondary beams present in FEL radiation. In the LCLS experiment the Hanbury Brown and Twiss type interferometry was performed on Bragg peaks from colloidal crystal. This did not require additional measurements without the sample and information was extracted directly from diffraction patterns. Therefore intensity

  3. Determination of diagnostic X ray spectra scattered by a phantom

    Energy Technology Data Exchange (ETDEWEB)

    Fehrenbacher, G.; Panzer, W.; Regulla, D. [GSF - National Research Center for Environment and Health, Neuherberg (Germany). Inst. of Radiation Protection; Tesfu, K. [Addis Ababa Univ. (Ethiopia)

    1997-12-01

    Photon spectra are reported that result from the scatter of diagnostic X rays at an appropriate water phantom that represents a patient. The tube voltages considered are between 52 kV and 110 kV, the scatter angles from 10{sup o} to 142{sup o} to the normal radiation incidence direction. All spectral measurements were performed with a high-purity germanium detector. Spectral photon fluences are computed from the measured pulse height distribution by using an unfolding procedure. The required response functions of the detection system were obtained by using Monte Carlo methods. Reference is made to a catalogue compiling 35 spectra of scattered X rays in diagnostics resulting from a human substitute, together with information on relevant primary field parameters as well as air kerma for the scattered X rays. (Author).

  4. X-ray scattering on quantum cross-bars

    Energy Technology Data Exchange (ETDEWEB)

    Kuzmenko, Igor [Department of Physics, Ben-Gurion University, Beer-Sheva 84105 (Israel)]. E-mail: igorkuz@bgumail.bgu.ac.il

    2005-04-30

    X-ray scattering on quantum cross-bars (QCB) leads to creation of QCB plasmon. Such a process corresponds to a sharp peak of frequency dependence of the differential scattering cross-section. The peak frequency strongly depends on the direction of the scattered light. As a result, 1D->2D cross-over can be observed in the scattering spectrum. It manifests itself in special directions as an appearance of doublets instead of a single line.

  5. Dense Plasma X-ray Scattering: Methods and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Glenzer, S H; Lee, H J; Davis, P; Doppner, T; Falcone, R W; Fortmann, C; Hammel, B A; Kritcher, A L; Landen, O L; Lee, R W; Munro, D H; Redmer, R; Weber, S

    2009-08-19

    We have developed accurate x-ray scattering techniques to measure the physical properties of dense plasmas. Temperature and density are inferred from inelastic x-ray scattering data whose interpretation is model-independent for low to moderately coupled systems. Specifically, the spectral shape of the non-collective Compton scattering spectrum directly reflects the electron velocity distribution. In partially Fermi degenerate systems that have been investigated experimentally in laser shock-compressed beryllium, the Compton scattering spectrum provides the Fermi energy and hence the electron density. We show that forward scattering spectra that observe collective plasmon oscillations yield densities in agreement with Compton scattering. In addition, electron temperatures inferred from the dispersion of the plasmon feature are consistent with the ion temperature sensitive elastic scattering feature. Hence, theoretical models of the static ion-ion structure factor and consequently the equation of state of dense matter can be directly tested.

  6. X-ray scattering signatures of {beta}-thalassemia

    Energy Technology Data Exchange (ETDEWEB)

    Desouky, Omar S. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT) (Egypt); Elshemey, Wael M. [Biophysics Department, Faculty of Science, Cairo University (Egypt)], E-mail: waelelshemey@yahoo.com; Selim, Nabila S. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT) (Egypt)

    2009-08-11

    X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, lyophilized and measured using a conventional X-ray diffractometer. Results show significant differences in the X-ray scattering profiles of most of the diseased samples compared to control. The shape of the first scattering peak at 0.27 nm{sup -1}, in addition to the relative intensity of the first to the second scattering peaks, provides the most reliable signs of abnormality in diseased samples. The results are interpreted and confirmed with the aid of Fourier Transform Infrared (FTIR) spectroscopy of normal and thalassemia samples.

  7. Imaging X-ray Thomson Scattering Spectrometer Design and Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Gamboa, E.J. [University of Michigan; Huntington, C.M. [University of Michigan; Trantham, M.R. [University of Michigan; Keiter, P.A [University of Michigan; Drake, R.P. [University of Michigan; Montgomery, David [Los Alamos National Laboratory; Benage, John F. [Los Alamos National Laboratory; Letzring, Samuel A. [Los Alamos National Laboratory

    2012-05-04

    In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally-curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

  8. Warm, Dense Plasma Characterization by X-ray Thomson Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; Glenzer, S H; Cauble, R C; Lee, R W; Edwards, J E; Degroot, J S

    2000-07-18

    We describe how the powerful technique of spectrally resolved Thomson scattering can be extended to the x-ray regime, for direct measurements of the ionization state, density, temperature, and the microscopic behavior of dense cool plasmas. Such a direct measurement of microscopic parameters of solid density plasmas could eventually be used to properly interpret laboratory measurements of material properties such as thermal and electrical conductivity, EUS and opacity. In addition, x-ray Thomson scattering will provide new information on the characteristics of rarely and hitherto difficult to diagnose Fermi degenerate and strongly coupled plasmas.

  9. X-ray holography with an atomic scatterer

    Energy Technology Data Exchange (ETDEWEB)

    Mityureva, A.A.; Smirnov, V.V., E-mail: valery_smirnov@mail.ru

    2016-08-15

    X-ray holography scheme with reference scatterer consisting of heavy atom as reference center and its link to an object consisting of several light atoms and using controlled variation of the alignment is represented. The scheme can reproduce an object in three dimensions with atomic resolution. The distorting factors of reconstruction are considered. - Highlights: • X-ray holography scheme with a reference wave formed by atomic scatterer. • 3D object reconstruction with atomic resolution from the set of holograms. • Simple formula for the distorting factor in reconstruction.

  10. The effect of bound states on X-ray Thomson scattering for partially ionized plasmas

    CERN Document Server

    Nilsen, J; Cheng, K T

    2013-01-01

    X-ray Thomson scattering is being developed as a method to measure the temperature, electron density, and ionization state of high energy density plasmas such as those used in inertial confinement fusion. X-ray laser sources have always been of interest because of the need to have a bright monochromatic x-ray source to overcome plasma emission and eliminate other lines in the background that complicate the analysis. With the advent of the xray free electron laser (X-FEL) at the SLAC Linac Coherent Light Source (LCLS) and other facilities coming online worldwide, we now have such a source available in the keV regime. Most Thomson scattering codes used to model experimental data greatly simplify or neglect the contributions of the bound electrons to the scattered intensity. In this work we take the existing models of Thomson scattering that include elastic ion-ion scattering and inelastic electron-electron scattering and add the contribution of bound electrons in the partially ionized plasmas. To date, most exp...

  11. Basic X-ray scattering for soft matter

    CERN Document Server

    De Jeu, Wim H

    2016-01-01

    X-ray scattering is a well-established technique in materials science. Several excellent textbooks exist in the field, typically written by physicists who use mathematics to make things clear. Often these books do not reach students and scientists in the field of soft matter (polymers, liquid crystals, colloids, and self-assembled organic systems), who usually have a chemical-oriented background with limited mathematics. Moreover, often these people like to know more about x-ray scattering as a technique to be used, but do not necessarily intend to become an expert. This volume is unique in trying to accommodate both points. The aim of the book is to explain basic principles and applications of x-ray scattering in a simple way. The intention is a paperback of limited size that people will like to have on hand rather than on a shelf. Second, it includes a large variety of examples of x-ray scattering of soft matter with, at the end of each chapter, a more elaborate case study. Third, the book contains a separa...

  12. X-ray scattering from surfaces of organic crystals

    DEFF Research Database (Denmark)

    Gidalevitz, D.; Feidenhans'l, R.; Smilgies, D.-M.

    1997-01-01

    X-ray scattering experiments have been performed on the surfaces of organic crystals. The (010) cleavage planes of beta-alanine and alpha-glycine were investigated, and both specular and off-specular crystal truncation rods were measured. This allowed a determination of the molecular layering...

  13. Development of general X-ray scattering model

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Joe, E-mail: jngray@iastate.edu; Wendt, Scott, E-mail: jngray@iastate.edu [Center for NDE, Iowa State University, Ames, IA 50011 (United States)

    2015-03-31

    X-ray scattering is a complex process made difficult to describe due to the effects of a complex energy spectrum interacting with a wide range of material types in complex geometry. The scattering is further complicated by the volume of material illuminated and the experimental configuration of the data acquisition. The importance of accounting for the key physics in scattering modeling is critical to the viability of the model. For example, scattering in the detector and the speed of the detector, as measured by the absorbed dose needed to produce a signal, are important in capturing undercut effects. Another example is the noise properties of the detectors are dependent on photon energy. We report on a semi-empirical treatment of x-ray scattering that includes a full energy treatment for a wide range of material types. We also include complex geometry effects that the part shape introduces. The treatment is based on experimental measurements using an energy dispersive germanium detector over energies from treatment is showing good results with experimental measurements of the scattering component agreeing with the model results to the 10% level over the range of x-ray energies and materials typical in industrial applications. Computation times for this model are in the 20 keV to 320 keV. Detector stripping routines for detector artifacts were developed. The computation time is in the range of a few minutes on a typical PC.

  14. Crystal defect studies using x-ray diffuse scattering

    Energy Technology Data Exchange (ETDEWEB)

    Larson, B.C.

    1980-01-01

    Microscopic lattice defects such as point (single atom) defects, dislocation loops, and solute precipitates are characterized by local electronic density changes at the defect sites and by distortions of the lattice structure surrounding the defects. The effect of these interruptions of the crystal lattice on the scattering of x-rays is considered in this paper, and examples are presented of the use of the diffuse scattering to study the defects. X-ray studies of self-interstitials in electron irradiated aluminum and copper are discussed in terms of the identification of the interstitial configuration. Methods for detecting the onset of point defect aggregation into dislocation loops are considered and new techniques for the determination of separate size distributions for vacancy loops and interstitial loops are presented. Direct comparisons of dislocation loop measurements by x-rays with existing electron microscopy studies of dislocation loops indicate agreement for larger size loops, but x-ray measurements report higher concentrations in the smaller loop range. Methods for distinguishing between loops and three-dimensional precipitates are discussed and possibilities for detailed studies considered. A comparison of dislocation loop size distributions obtained from integral diffuse scattering measurements with those from TEM show a discrepancy in the smaller sizes similar to that described above.

  15. Theory of inelastic scattering and absorption of X-rays

    CERN Document Server

    Veenendaal, Michel van

    2015-01-01

    This comprehensive, self-contained guide to X-ray spectroscopy will equip you with everything you need to begin extracting the maximum amount of information available from X-ray spectra. Key topics such as the interaction between X-rays and matter, the basic theory of spectroscopy, and selection and sum rules, are introduced from the ground up, providing a solid theoretical grounding. The book also introduces core underlying concepts such as atomic structure, solid-state effects, the fundamentals of tensor algebra and group theory, many-body interactions, scattering theory, and response functions, placing spectroscopy within a broader conceptual framework, and encouraging a deep understanding of this essential theoretical background. Suitable for graduate students, researchers, materials scientists and optical engineers, this is the definitive guide to the theory behind this powerful and widely used technique.

  16. Development and Applications of a Laboratory Micro X-ray Fluorescence (μXRF) Spectrometer Using Monochromatic Excitation for Quantitative Elemental Analysis.

    Science.gov (United States)

    Garrevoet, Jan; Vekemans, Bart; Bauters, Stephen; Demey, Arne; Vincze, Laszlo

    2015-07-07

    The analytical characterization and an application example of a novel laboratory X-ray fluorescence (μXRF) microprobe is presented, which combines monochromatic, focused X-ray beam excitation with a high-performance silicon drift detector (SDD) and two-dimensional/three-dimensional (2D/3D) scanning capability. Because of the monochromatic excitation, below the (multiple) Compton/Rayleigh scattering peak region, the XRF spectra obtained by this laboratory spectrometer has similarly high peak-to-background ratios as those which can be obtained at synchrotron sources. However, the flux density difference between the proposed laboratory instrument and current synchrotron end stations is on the order of several orders of magnitude. As a result, sub-ppm minimum detection limits (MDL) for transition metals are obtained for a variety of sample matrices. The monochromatic excitation also allows for the efficient use of an iterative Monte Carlo simulation algorithm to obtain quantitative information on the analyzed samples. The analytical characteristics of this instrument and quantitative results, in combination with an iterative reverse Monte Carlo simulation algorithm, will be demonstrated using measurements conducted on an iron-containing meteorite.

  17. Resonant magnetic scattering of polarized soft x rays

    Energy Technology Data Exchange (ETDEWEB)

    Sacchi, M. [Centre Universitaire Paris-Sud, Orsay (France); Hague, C.F. [Universite Pierre et Marie Curie, Paris (France); Gullikson, E.M.; Underwood, J. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    Magnetic effects on X-ray scattering (Bragg diffraction, specular reflectivity or diffuse scattering) are a well known phenomenon, and they also represent a powerful tool for investigating magnetic materials since it was shown that they are strongly enhanced when the photon energy is tuned across an absorption edge (resonant process). The resonant enhancement of the magnetic scattering has mainly been investigated at high photon energies, in order to match the Bragg law for the typical lattice spacings of crystals. In the soft X-ray range, even larger effects are expected, working for instance at the 2p edges of transition metals of the first row or at the 3d edges of rare earths (300-1500 eV), but the corresponding long wavelengths prevent the use of single crystals. Two approaches have been recently adopted in this energy range: (i) the study of the Bragg diffraction from artificial structures of appropriate 2d spacing; (ii) the analysis of the specular reflectivity, which contains analogous information but has no constraints related to the lattice spacing. Both approaches have their own specific advantages: for instance, working under Bragg conditions provides information about the (magnetic) periodicity in ordered structures, while resonant reflectivity can easily be related to electronic properties and absorption spectra. An important aspect common to all the resonant X-ray scattering techniques is the element selectivity inherent to the fact of working at a specific absorption edge: under these conditions, X-ray scattering becomes in fact a spectroscopy. Results are presented for films of iron and cobalt.

  18. Total X-Ray Scattering of Spider Dragline Silk

    Science.gov (United States)

    Benmore, C. J.; Izdebski, T.; Yarger, J. L.

    2012-04-01

    Total x-ray scattering measurements of spider dragline silk fibers from Nephila clavipes, Argiope aurantia, and Latrodectus hesperus all yield similar structure factors, with only small variations between the different species. Wide-angle x-ray scattering from fibers orientated perpendicular to the beam shows a high degree of anisotropy, and differential pair distribution functions obtained by integrating over wedges of the equatorial and meridian planes indicate that, on average, the majority (95%) of the atom-atom correlations do not extend beyond 1 nm. Futhermore, the atom-atom correlations between 1 and 3 nm are not associated with the most intense diffraction peaks at Q=1-2Å-1. Disordered molecular orientations along the fiber axis are consistent with proteins in similar structural arrangements to those in the equatorial plane, which may be associated with the silk’s greater flexibility in this direction.

  19. Advancing X-ray scattering metrology using inverse genetic algorithms.

    Science.gov (United States)

    Hannon, Adam F; Sunday, Daniel F; Windover, Donald; Kline, R Joseph

    2016-01-01

    We compare the speed and effectiveness of two genetic optimization algorithms to the results of statistical sampling via a Markov chain Monte Carlo algorithm to find which is the most robust method for determining real space structure in periodic gratings measured using critical dimension small angle X-ray scattering. Both a covariance matrix adaptation evolutionary strategy and differential evolution algorithm are implemented and compared using various objective functions. The algorithms and objective functions are used to minimize differences between diffraction simulations and measured diffraction data. These simulations are parameterized with an electron density model known to roughly correspond to the real space structure of our nanogratings. The study shows that for X-ray scattering data, the covariance matrix adaptation coupled with a mean-absolute error log objective function is the most efficient combination of algorithm and goodness of fit criterion for finding structures with little foreknowledge about the underlying fine scale structure features of the nanograting.

  20. Polarized X-ray Scattering and Birefringence in Magnetars

    Science.gov (United States)

    Barchas, Joseph; Baring, Matthew G.

    2017-01-01

    Interest in radiative processes in the super-strong magnetic regime germane to magnetars has grown over the last two decades. These processes have an inherently anisotropic and polarization-dependent character. Of particular interest is the resonant cyclotron scattering domain, where the Compton cross section is enhanced by orders of magnitude very near the cyclotron frequency -- for electrons in magnetar atmospheres, this is above 10 MeV in energy, and for protons this can be at 1-10 keV. The Compton process is dominant in the highly optically thick environs of magnetar atmospheres, and also in the magnetospheric locales for the production of the hard X-ray bursts. The detailed forms of X-ray spectra will depend intimately on the character of the Compton cross section and the emission zone geometry. The practical determination of the rate of Compton scattering depends on the polarization configuration of incoming photons. This in turn is sensitive to the details of radiation dispersion and transport in hot plasmaspheres near neutron stars. This birefringent dispersion present in strongly-magnetized plasmas can profoundly influence the determination of scattering probabilities. Such polarization transfer is usually addressed by simplifying to the transfer two normal mode intensities. The assumptions involved in this simplification such as orthonormality and "large Faraday depolarization" are valid for a wide range of parameter space, but are known to break down in important cases, such as near a cyclotron resonance. We explore the polarization transfer problem for Compton scattering including the regime where Faraday depolarization is not large. Accordingly, plasma birefringence and the generalized Faraday effect are considered explicitly as part of the transfer problem. Spectra generated from two Monte Carlo models of the transfer problem are presented, one treating isothermal atmospheres in the normal X-ray band, and the other addressing hard X-ray flares in

  1. Linear dichroism in molecular resonant inelastic x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Lindle, D W; Stolte, W C [Department of Chemistry, University of Nevada, Las Vegas, NV 89154-4003 (United States); Guillemint, R; Carniato, S; Journel, L; Taieb, R; Simon, M, E-mail: lindle@unlv.nevada.ed [UPMC, CNRS U Paris 06, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France)

    2009-11-01

    Polarization-dependent resonant inelastic x-ray scattering (RIXS) is shown to be a new probe of molecular-field effects on molecular electronic structure. Combining experiment and theory, linear dichroism in Cl 2p RIXS following Cl 1s excitation in HCl, Cl{sub 2}, and CF{sub 3}Cl is ascribed to molecular-field effects, indicating polarized-RIXS provides a direct probe of spin-orbit-state populations generally applicable to all molecules.

  2. Dense Matter Characterization by X-ray Thomson Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; Glenzer, S H; Edwards, M J; Lee, R W; Collins, G W; Cauble, R C; Hsing, W W; Hammel, B A

    2000-12-29

    We discuss the extension of the powerful technique of Thomson scattering to the x-ray regime for providing an independent measure of plasma parameters for dense plasmas. By spectrally-resolving the scattering, the coherent (Rayleigh) unshifted scattering component can be separated from the incoherent Thomson component, which is both Compton and Doppler shifted. The free electron density and temperature can then be inferred from the spectral shape of the high frequency Thomson scattering component. In addition, as the plasma temperature is decreased, the electron velocity distribution as measured by incoherent Thomson scattering will make a transition from the traditional Gaussian Boltzmann distribution to a density-dependent parabolic Fermi distribution to. We also present a discussion for a proof-of-principle experiment appropriate for a high energy laser facility.

  3. High duty cycle inverse Compton scattering X-ray source

    Science.gov (United States)

    Ovodenko, A.; Agustsson, R.; Babzien, M.; Campese, T.; Fedurin, M.; Murokh, A.; Pogorelsky, I.; Polyanskiy, M.; Rosenzweig, J.; Sakai, Y.; Shaftan, T.; Swinson, C.

    2016-12-01

    Inverse Compton Scattering (ICS) is an emerging compact X-ray source technology, where the small source size and high spectral brightness are of interest for multitude of applications. However, to satisfy the practical flux requirements, a high-repetition-rate ICS system needs to be developed. To this end, this paper reports the experimental demonstration of a high peak brightness ICS source operating in a burst mode at 40 MHz. A pulse train interaction has been achieved by recirculating a picosecond CO2 laser pulse inside an active optical cavity synchronized to the electron beam. The pulse train ICS performance has been characterized at 5- and 15- pulses per train and compared to a single pulse operation under the same operating conditions. With the observed near-linear X-ray photon yield gain due to recirculation, as well as noticeably higher operational reliability, the burst-mode ICS offers a great potential for practical scalability towards high duty cycles.

  4. INELASTIC X-RAY SCATTERING AT ULTRAHIGH PRESSURES.

    Energy Technology Data Exchange (ETDEWEB)

    MAO, H.K.; HEMLEY, J.; KAO, C.C.

    2000-08-28

    Inelastic x-ray scattering (IXS) provides high-pressure research with an arsenal of analytical capabilities for key measurements that were previously unattainable, and high pressure research provides IXS with numerous applications where the technique has unique advantages over other methods. High-pressure investigations can now be conducted using non-resonant IXS, resonant IXS, nuclear resonant IXS, and x-ray emission spectroscopy with energy resolutions of 100 meV to 1 eV for electronic transitions and 1 to 10 meV for phonon studies. By pressure-tuning materials over a wide range, we are able to investigate fundamental physics of electron gases, strongly correlated electron systems, high-energy electronic excitations, and phonons in energy and momentum space. The results will have a profound influence on materials applications as well as providing basic information for understanding the deep interior of the Earth and other planets.

  5. X-band RF gun and linac for medical Compton scattering X-ray source

    Science.gov (United States)

    Dobashi, Katsuhito; Uesaka, Mitsuru; Fukasawa, Atsushi; Sakamoto, Fumito; Ebina, Futaro; Ogino, Haruyuki; Urakawa, Junji; Higo, Toshiyasu; Akemoto, Mitsuo; Hayano, Hitoshi; Nakagawa, Keiichi

    2004-12-01

    Compton scattering hard X-ray source for 10-80 keV are under construction using the X-band (11.424 GHz) electron linear accelerator and YAG laser at Nuclear Engineering Research laboratory, University of Tokyo. This work is a part of the national project on the development of advanced compact medical accelerators in Japan. National Institute for Radiological Science is the host institute and U.Tokyo and KEK are working for the X-ray source. Main advantage is to produce tunable monochromatic hard (10-80 keV) X-rays with the intensities of 108-1010 photons/s (at several stages) and the table-top size. Second important aspect is to reduce noise radiation at a beam dump by adopting the deceleration of electrons after the Compton scattering. This realizes one beamline of a 3rd generation SR source at small facilities without heavy shielding. The final goal is that the linac and laser are installed on the moving gantry. We have designed the X-band (11.424 GHz) traveling-wave-type linac for the purpose. Numerical consideration by CAIN code and luminosity calculation are performed to estimate the X-ray yield. X-band thermionic-cathode RF-gun and RDS(Round Detuned Structure)-type X-band accelerating structure are applied to generate 50 MeV electron beam with 20 pC microbunches (104) for 1 microsecond RF macro-pulse. The X-ray yield by the electron beam and Q-switch Nd:YAG laser of 2 J/10 ns is 107 photons/RF-pulse (108 photons/sec at 10 pps). We design to adopt a technique of laser circulation to increase the X-ray yield up to 109 photons/pulse (1010 photons/s). 50 MW X-band klystron and compact modulator have been constructed and now under tuning. The construction of the whole system has started. X-ray generation and medical application will be performed in the early next year.

  6. Resonant inelastic scattering at intermediate X-ray energies

    CERN Document Server

    Hague, C F; Journel, L; Gallet, J J; Rogalev, A; Krill, G; Kappler, J P

    2000-01-01

    We describe resonant inelastic X-ray scattering (RIXS) experiments and magnetic circular dichroism (MCD) in X-ray fluorescence performed in the 3-5 keV range. The examples chosen are X-ray fluorescence MCD of FeRh and RIXS experiments performed at the L/sub 3/ edge of Ce. Fe Rh is antiferromagnetic at room temperature but has a transition to the ferromagnetic state above 400 K. The Rh MCD signal is compared with an augmented spherical wave calculation. The experiment confirms the predicted spin polarization of the Rh 4d valence states. The RIXS measurements on Ce compounds and intermetallics address the problem of mixed valency especially in systems where degeneracy with the Fermi level remains small. Examples are taken from the 2p to (4f5d) /sup +1/ followed by 3d to 2p RIXS for a highly ionic compound CeF /sub 3/ and for almost gamma -like CeCuSi. (38 refs).

  7. Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Plagnard, Johann; Bobin, Christophe; Lepy, Marie-Christine [Commissariat a l' Energie Atomique, Laboratoire National Henri Becquerel, 91191 Gif-sur-Yvette Cedex (France)

    2007-05-15

    HPGe detector efficiency has been calibrated using complementary methods involving radioactive x-ray standards, reference synchrotron flux (Super ACO, LURE, France) and a monochromatic x-ray source (SOLEX), combined with Monte Carlo simulation. In the study described here, SOLEX was used to determine the thickness of detector components that create absorption sites in front of the active zone of the detector, by energy scanning in the vicinity of their K and L binding energies. The layers of aluminium (infrared shielding), nickel (electrical contact) and germanium (dead layer) have been measured. This approach ensures accurate determination of the thickness of each component and enables the detector efficiency calculation by Monte Carlo simulation. Differences between simulated data and experimental efficiency values are about 1-5% at energies above 1400 eV and reach 20% at lower energies. (authors)

  8. IN SITU SURFACE X-RAY SCATTERING STUDIES OF ELECTROSORPTION

    Energy Technology Data Exchange (ETDEWEB)

    WANG,J.X.; ADZIC,R.R.; OCKO,B.M.

    1998-07-01

    A short review of the application of surface x-ray scattering techniques to the electrode/electrolyte interfaces is presented. Recent results on metal, halide, and metal-halide adlayers with three specific systems: Bi on Au(100) and Au(110); Br on Au(100) and Ag(100); and the coadsorption of Tl with Br or I on Au(111), are given as an illustration. Factors affecting ordering of pure metal and halide adlayers and the metal-halide surface compounds are discussed in some detail.

  9. Microfocus X-ray scattering investigations of eggshell nanotexture.

    Science.gov (United States)

    Lammie, Donna; Bain, Maureen M; Wess, Tim J

    2005-11-01

    The avian eggshell is a highly ordered calcitic bioceramic composite, with both inorganic and organic constituents. The interactions between the inorganic and organic components within the structure are poorly understood but are likely to occur at the nanometre level. Thus structural variation at this level may impinge on the overall structural integrity and mechanical performance of the eggshell, and therefore analysis at this level is fundamental in fully understanding this ordered structure. In this study, structural changes in the mineral crystallites were investigated by microfocus small-angle X-ray scattering (microSAXS) using synchrotron radiation. Small-angle X-ray scattering (SAXS) can be used to investigate structures on the nanometre scale such as size, shape, arrangement and internal porosity. A microfocused X-ray beam, 1.5 microm vertically by 7 microm, was used to produce vertical linear scans of the eggshell section. SAXS patterns were taken from the eggshell membrane (inner surface of the eggshell) to the cuticle (outer surface of the eggshell). This allowed textural variations within the eggshell to be mapped. The scattering intensity profile was then used to derive the dimension of scattering objects that define the nanotexture. The nanotexture observed may result from the presence of the organic matrix, which is embedded as intracrystalline particles producing voids within the calcified framework of large (>1 microm) calcite crystals. Porod analysis revealed the average size of a scattering interface to be approximately 4.5 nm with small changes that had a depth-dependent variation. These were largest at the mammillary layer/membrane boundary. The palisade layer displayed a small upward trend in size of scattering object. Parallel scans showed that the textural variations observed within the palisade layer are significant and indicate local subtextures. In addition, many of the patterns exhibit diffuse scattering streaks that could result from

  10. ORNL 10-m small-angle X-ray scattering camera

    Energy Technology Data Exchange (ETDEWEB)

    Hendricks, R.W.

    1979-12-01

    A new small-angle x-ray scattering camera utilizing a rotating anode x-ray source, crystal monochromatization of the incident beam, pinhole collimation, and a two-dimensional position-sensitive proportional counter was developed. The sample, and the resolution element of the detector are each approximately 1 x 1 mm/sup 2/, the camera was designed so that the focal spot-to-sample and sample-to-detector distances may each be varied in 0.5-m increments up to 5 m to provide a system resolution in the range 0.5 to 4.0 mrad. A large, general-purpose specimen chamber has been provided into which a wide variety of special-purpose specimen holders can be mounted. The detector has an active area of 200 x 200 mm and has up to 200 x 200 resolution elements. The data are recorded in the memory of a minicomputer by a high-speed interface which uses a microprocessor to map the position of an incident photon into an absolute minicomputer memory address. The data recorded in the computer memory can be processed on-line by a variety of programs designed to enhance the user's interaction with the experiment. At the highest angular resolution (0.4 mrad), the flux incident on the specimen is 1.0 x 10/sup 6/ photons/s with the x-ray source operating at 45 kV and 100 mA. SAX and its associated programs OVF and MOT are high-priority, pre-queued, nonresident foreground tasks which run under the ModComp II MAX III operating system to provide complete user control of the ORNL 10-m small-angle x-ray scattering camera.

  11. Low-angle X-ray scattering from spices

    Energy Technology Data Exchange (ETDEWEB)

    Desouky, O.S. E-mail: omardesouky@yahoo.com; Ashour, Ahmed H.; Abdullah, Mohamed I.; Elshemey, Wael M

    2002-07-01

    Low-angle scattering of X-rays is characterized by the presence of one or more peaks in the forward direction of scattering. These peaks are due to the interference of photons coherently scattered from the molecules of the medium. Thus these patterns are closely linked to the molecular structure of the investigated medium. In this work, low-angle X-ray scattering (LAXS) profiles of five spices; pimpinella anisum (anise), coriandrum sativum (coriander), cuminum cyminum (cumin), foenculum vulgare (fennel) and nigella sativa (nigella or black cumin) are presented after extensive measurements. It is found that all spices exhibit one characteristic peak at a scattering angle around 10 deg. This is equivalent to a value x=0.0565 A{sup -1}, where x=sin({theta}/2)/{lambda}. The full width at half maximum (FWHM) of this peak is found to be characteristic for each type of the investigated spices. The possibility to detect the irradiation of these spices from their LAXS profiles is also examined after 10, 20, 30 and 40 kGy doses of gamma radiation. Except for anise, coriander and cumin at 40 kGy, there are no detectable deviations from the control samples in the scattering profiles of irradiated samples. These results comply with the recommendations of the FDA (US Food and Drug Administration) which defines 30 kGy as the maximum dose for irradiation of spices. The present technique could be used to detect over-irradiation, which causes damage to the molecular structure of some spices.

  12. Low-angle X-ray scattering from spices

    Science.gov (United States)

    Desouky, Omar S.; Ashour, Ahmed H.; Abdullah, Mohamed I.; Elshemey, Wael M.

    2002-07-01

    Low-angle scattering of X-rays is characterized by the presence of one or more peaks in the forward direction of scattering. These peaks are due to the interference of photons coherently scattered from the molecules of the medium. Thus these patterns are closely linked to the molecular structure of the investigated medium. In this work, low-angle X-ray scattering (LAXS) profiles of five spices; pimpinella anisum (anise), coriandrum sativum (coriander), cuminum cyminum (cumin), foenculum vulgare (fennel) and nigella sativa (nigella or black cumin) are presented after extensive measurements. It is found that all spices exhibit one characteristic peak at a scattering angle around 10°. This is equivalent to a value x=0.0565 Å -1, where x=sin( θ⧸2)⧸ λ. The full width at half maximum (FWHM) of this peak is found to be characteristic for each type of the investigated spices. The possibility to detect the irradiation of these spices from their LAXS profiles is also examined after 10, 20, 30 and 40 kGy doses of gamma radiation. Except for anise, coriander and cumin at 40 kGy, there are no detectable deviations from the control samples in the scattering profiles of irradiated samples. These results comply with the recommendations of the FDA (US Food and Drug Administration) which defines 30 kGy as the maximum dose for irradiation of spices. The present technique could be used to detect over-irradiation, which causes damage to the molecular structure of some spices.

  13. Femtosecond X-ray scattering in condensed matter

    Energy Technology Data Exchange (ETDEWEB)

    Korff Schmising, Clemens von

    2008-11-24

    This thesis investigates the manifold couplings between electronic and structural properties in crystalline Perovskite oxides and a polar molecular crystal. Ultrashort optical excitation changes the electronic structure and the dynamics of the connected reversible lattice rearrangement is imaged in real time by femtosecond X-ray scattering experiments. An epitaxially grown superlattice consisting of alternating nanolayers of metallic and ferromagnetic strontium ruthenate (SRO) and dielectric strontium titanate serves as a model system to study optically generated stress. In the ferromagnetic phase, phonon-mediated and magnetostrictive stress in SRO display similar sub-picosecond dynamics, similar strengths but opposite sign and different excitation spectra. The amplitude of the magnetic component follows the temperature dependent magnetization square, whereas the strength of phononic stress is determined by the amount of deposited energy only. The ultrafast, phonon-mediated stress in SRO compresses ferroelectric nanolayers of lead zirconate titanate in a further superlattice system. This change of tetragonal distortion of the ferroelectric layer reaches up to 2 percent within 1.5 picoseconds and couples to the ferroelectric soft mode, or ion displacement within the unit cell. As a result, the macroscopic polarization is reduced by up to 100 percent with a 500 femtosecond delay that is due to final elongation time of the two anharmonically coupled modes. Femtosecond photoexcitation of organic chromophores in a molecular, polar crystal induces strong changes of the electronic dipole moment via intramolecular charge transfer. Ultrafast changes of transmitted X-ray intensity evidence an angular rotation of molecules around excited dipoles following the 10 picosecond kinetics of the charge transfer reaction. Transient X-ray scattering is governed by solvation, masking changes of the chromophore's molecular structure. (orig.)

  14. Imaging Nonequilibrium Atomic Vibrations with X-ray Diffuse Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Trigo, M.; Chen, J.; Vishwanath, V.H.; /SLAC; Sheu, Y.M.; /Michigan U.; Graber, T.; Henning, R.; /U. Chicago; Reis, D; /SLAC /Stanford U., Appl. Phys. Dept.

    2011-03-03

    We use picosecond x-ray diffuse scattering to image the nonequilibrium vibrations of the lattice following ultrafast laser excitation. We present images of nonequilibrium phonons in InP and InSb throughout the Brillouin-zone which remain out of equilibrium up to nanoseconds. The results are analyzed using a Born model that helps identify the phonon branches contributing to the observed features in the time-resolved diffuse scattering. In InP this analysis shows a delayed increase in the transverse acoustic (TA) phonon population along high-symmetry directions accompanied by a decrease in the longitudinal acoustic (LA) phonons. In InSb the increase in TA phonon population is less directional.

  15. Note: Construction of x-ray scattering and x-ray absorption fine structure beamline at the Pohang Light Source.

    Science.gov (United States)

    Lee, Ik-Jae; Yu, Chung-Jong; Yun, Young-Duck; Lee, Chae-Soon; Seo, In Deuk; Kim, Hyo-Yun; Lee, Woul-Woo; Chae, Keun Hwa

    2010-02-01

    A new hard x-ray beamline, 10B KIST-PAL beamline (BL10B), has been designed and constructed at the Pohang Light Source (PLS) in Korea. The beamline, operated by Pohang Accelerator Laboratory-Korean Institute of Science and Technology consortium, is dedicated to x-ray scattering (XRS) and x-ray absorption fine structure (XAFS) experiments. X rays with photon energies from 4.0 to 16.0 keV are delivered to the experimental station passing a collimating mirror, a fixed-exit double-crystal Si(111) monochromator, and a toroidal mirror. Basic experimental equipment for XAFS measurement, a high resolution diffractometry, an image plate detector system, and a hot stage have been prepared for the station. From our initial commissioning and performance testing of the beamline, it is observed that BL10B beamline can perform XRS and XAFS measurements successfully.

  16. Low angle X-ray scattering in biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Lemos, Carla; Braz, Delson; Pinto, Nivia G.V.; Lima, Joao C.; Castro, Carlos R.F.; Filgueiras, R.A.; Mendonca, Leonardo; Lopes, Ricardo T. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Lab. de Instrumentacao Nuclear]. E-mail: delson@lin.ufrj.br; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica]. E-mail: cely@uerj.br

    2007-07-01

    Low-angle x-ray scatter (LAXS) for tissue characterization is based on the differences which result from the interference of photons coherently scattered from molecules of each sample. Biological samples (bone, blood and blood components) have been studied in recent years in our laboratory using powder diffractometer. The scattering information was obtained using a Shimadzu DRX 6000 diffractometer at the Nuclear Instrumentation Laboratory, Rio de Janeiro, Brazil. Unpolarized monoenergetic K{alpha} radiation from Cu provided 8.04 keV photons. The measurements were made in reflection mode ({theta}-2{theta} geometry), with the sample stationary on a goniometer which rotates the sample and detector about an axis lying in the plane of the top of the sample holder. LAXS profiles from whole blood, plasma and formed elements were measured to investigate the nature of scattering from such lyophilized samples. The statistical analysis shows that the variation found for the characterization parameters is significant for whole blood considering the age. Gender was positively associated with the variation of the second peak position for the profiles obtained for formed elements. The correlation of the measured relative coherent intensity with the mineral content in the bone samples was investigated. These results suggest that the measurement of bone mineral content within trabecular bone can be performed by using quantitative coherent scattering information. (author)

  17. Oxide Nanolayers in Stratified Samples Studied by X-Ray Resonant Raman Scattering at Grazing Incidence

    Directory of Open Access Journals (Sweden)

    Juan José Leani

    2015-01-01

    Full Text Available X-ray resonant Raman scattering is applied at grazing incidence conditions with the aim of discriminating and identifying chemical environment of iron in different layers of stratified materials using a low resolution energy dispersive system. The methodology allows for depth studies with nanometric resolution. Nanostratified samples of Fe oxides were studied at the Brazilian synchrotron facility (LNLS using monochromatic radiation and an EDS setup. The measurements were carried out in grazing incident regime with incident photon energy lower than and close to the Fe-K absorption edge. The result allowed for characterizing oxide nanolayers, not observable with conventional geometries, identifying the oxidation state present in a particular depth of a sample surface with nanometric, or even subnanometric, resolution using a low-resolution system.

  18. X-Ray Scattering Applications Using Pulsed X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Larson, B.C.

    1999-05-23

    Pulsed x-ray sources have been used in transient structural phenomena investigations for over fifty years; however, until the advent of synchrotrons sources and the development of table-top picosecond lasers, general access to ligh temporal resolution x-ray diffraction was relatively limited. Advances in diffraction techniques, sample excitation schemes, and detector systems, in addition to IncEased access to pulsed sources, have ld tO what is now a diverse and growing array of pulsed-source measurement applications. A survey of time-resolved investigations using pulsed x-ray sources is presented and research opportunities using both present and planned pulsed x-ray sources are discussed.

  19. Demonstration experiment of a laser synchrotron source for tunable, monochromatic x-rays at 500 eV

    Energy Technology Data Exchange (ETDEWEB)

    Ting, A.; Fischer, R.; Fisher, A. [Naval Research Lab., Washington, DC (United States)] [and others

    1995-12-31

    A Laser Synchrotron Source (LSS) was proposed to generate short-pulsed, tunable x-rays by Thomson scattering of laser photons from a relativistic electron beam. A proof-of-principle experiment was performed to generate x-ray photons of 20 eV. A demonstration experiment is being planned and constructed to generate x-ray photons in the range of {approximately}500 eV. Laser photons of {lambda}=1.06 {mu}m are Thomson backscattered by a 4.5 MeV electron beam which is produced by an S-band RF electron gun. The laser photons are derived from either (i) a 15 Joules, 3 nsec Nd:glass laser, (ii) the uncompressed nsec: pulse of the NRL table-top terawatt (T{sup 3}) laser, or (iii) the compressed sub-picosec pulse of the T{sup 3} laser. The RF electron gun is being constructed with initial operation using a thermionic cathode. It will be upgraded to a photocathode to produce high quality electron beams with high current and low emittance. The x-ray pulse structure consists of {approximately}10 psec within an envelope of a macropulse whose length depends on the laser used. The estimated x-ray photon flux is {approximately}10{sup 18} photons/sec, and the number of photons per macropulse is {approximately}10{sup 8}. Design parameters and progress of the experiment will be presented.

  20. Inelastic x-ray scattering measurements of liquid waterglycerol mixtures

    Science.gov (United States)

    Kajihara, Yukio; Shibata, Nanako; Inui, Masanori; Matsuda, Kazuhiro; Tsutsui, Satoshi

    2017-08-01

    We have carried out inelastic x-ray scattering measurements on liquid water-glycerol mixtures. The data are analyzed by a damped harmonic oscillator model with two excitations, longitudinal and transverse modes. The sound velocity of the longitudinal mode is almost constant (about 3.1 km/s), being independent of the composition. Thus the strength of 'fast sound' which we define the ratio of this IXS sound velocity to ultrasonic one is largest at pure water and gradually decrease with increasing mole fraction of glycerol. This result indicates that the relaxation phenomena of pure water gradually reduce with increasing the fraction of the solute: the scenario which we proposed for water-monohydric alcohol mixtures hold true for this water-trihydric alcohol mixtures.

  1. X-ray Intermolecular Structure Factor (XISF): separation of intra- and intermolecular interactions from total X-ray scattering data

    Energy Technology Data Exchange (ETDEWEB)

    Mou, Q.; Benmore, C. J.; Yarger, J. L.

    2015-06-01

    XISF is a MATLAB program developed to separate intermolecular structure factors from total X-ray scattering structure factors for molecular liquids and amorphous solids. The program is built on a trust-region-reflective optimization routine with the r.m.s. deviations of atoms physically constrained. XISF has been optimized for performance and can separate intermolecular structure factors of complex molecules.

  2. Determination of interfacial roughness using X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Munkholm, Anneli [Stanford Univ., CA (United States)

    1997-05-01

    Crystal truncation rod (CTR) scattering is shown to be a powerful technique for determining interfacial roughness non-destructively. By measuring the decay of scattering away from a Bragg reflection in the surface direction an rms roughness of the surface or interface can be extracted. The authors obtain rms roughness values with an accuracy of ± 0.1 Å. Sensitivity to lateral length scale roughness ranges from the wavelength of the x-rays to between 1,000--10,000 Å depending on the instrument function and the specific truncation rod. The influence of different cleans, as well as the thermal oxidation process, on the Si-SiO2 interface is investigated. A hot water treatment prior to the thermal oxidation is shown to roughen the Si-SiO2 interface. CTR scattering results also show a smoothing of the interface as a result of the oxidation process even for as little as 60 Å of thermal oxidation. Comparison between AFM and CTR scattering gives a consistent picture of the relative roughness of the wafers, although the absolute numbers do not agree. The differences in the absolute values can be explained by the lateral roughness scale that the two techniques measure, indicating that it is at periodicities below ~ 100 Å that the increased roughness observed by the x-ray is found. Crystal truncation rods are shown to be perpendicular to the surface and not along the crystallographic axes of a miscut crystal. It is shown that for a crystal terminated by a regular step array both an atomistic and a continuum description of CTR scattering give identical results. Furthermore, the atomistic approach is used to show that a diamond cubic surface with a miscut is inherently rough. Even for a small miscut the tilt of the CTR with respect to the crystallographic axes results in complications for measuring the rod intensity. The authors present schemes for determining the exact position of the CTR in reciprocal space and for measuring the miscut of a single

  3. Monochromatic flash x-ray generator utilizing a disk-cathode silver tube

    Science.gov (United States)

    Sato, Eiichi; Hayasi, Yasuomi; Germer, Rudolf K. F., II; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Inoue, Takashi; Ogawa, Akira; Sato, Shigehiro; Ichimaru, Toshio; Takayama, Kazuyoshi; Onagawa, Jun; Ido, Hideaki

    2005-09-01

    The high-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -50 to -70 kV by a power supply, and the electric charges in the condensers are discharged to an x-ray tube after closing gap switches in the surge generator with a trigger device. The x-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Clean silver Kα lines are produced using a 30-μm-thick palladium filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. At a charging voltage of -70 kV, the instantaneous tube voltage and current are 90 kV and 0.8 kA, respectively. The x-ray pulse widths are approximately 80 ns, and the instantaneous number of generator-produced Kα photons is approximately 4×107photons/cm2 per pulse at 0.3 m from the source 3.0 mm in diameter.

  4. Monochromatic flash x-ray generator utilizing disk-cathode silver tube

    Science.gov (United States)

    Sato, Eiichi; Hayasi, Yasuomi; Germer, Rudolf K.; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ichimaru, Toshio; Takayama, Kazuyoshi; Ido, Hideaki

    2004-11-01

    The high-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -50 to -70 kV by a power supply, and the electric charges in the condensers are discharged to an x-ray tube after closing gap switches in the surge generator with a trigger device. The x-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Clean silver Kα lines are produced using a 30 μm-thick palladium filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. At a charging voltage of -70 kV, the instantaneous tube voltage and current were 90 kV and 0.8 kA, respectively. The x-ray pulse widths were approximately 80 ns, and the instantaneous number of generator-produced Kα photons was approximately 40 M photons/cm2 per pulse at 0.3 m from the source of 3.0 mm in diameter.

  5. Monochromatic flash x-ray generator utilizing copper-target diode

    Science.gov (United States)

    Sato, Eiichi; Sagae, Michiaki; Komatsu, Makoto; Germer, Rudolf; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ichimaru, Toshio; Sato, Shigehiro; Ojima, Hidenori; Takayama, Kazuyoshi; Ido, Hideaki

    2005-03-01

    High-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -50 to -70 kV using a power supply, and the electric charges in the condensers are discharged to an x-ray tube after closing the gap switches in the surge generator using a trigger device. The x-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Clean copper Kα lines are produced using a 10-μm-thick nickel filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. The peak tube voltage increased with increasing charging voltage. At a charging voltage of -70 kV, the peak tube voltage and current were 140 kV and 0.8 kA, respectively. The pulse widths were approximately 30 ns, and the maximum dimension of the x-ray source was 3.0 mm in diameter. The number of generator-produced Kα photons was approximately 2.5x106 photons/cm2 at 0.5 m per pulse.

  6. Probing surface and interface morphology with Grazing Incidence Small Angle X-Ray Scattering

    National Research Council Canada - National Science Library

    Renaud, Gilles; Lazzari, Rémi; Leroy, Frédéric

    2009-01-01

    .... their shapes, their sizes and their spatial organization. This calls for dedicated morphological characterization tools, among which is the Grazing Incidence Small Angle X-Ray Scattering (GISAXS...

  7. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    Abstract. The morphology of carbon nanofoam samples comprising platinum nanopar- ticles dispersed in the matrix was characterized by small angle neutron scattering (SANS) and small angle X-ray scattering (SAXS) techniques. Results show that the structure of pores of carbon matrix exhibits a mass (pore) fractal nature ...

  8. Resource Letter on Stimulated Inelastic X-ray Scattering at an XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Patterson, Bruce D.; /SLAC

    2010-09-02

    At sufficient X-ray intensity, stimulated effects in inelastic scattering will become important. These coherent, non-linear optical phenomena may be used to impulsively produce a high degree of collective excitation in, for example, correlated electron materials, suitable for performing ultrafast time-resolved spectroscopy. This Resource Letter collects information on fundamental aspects of stimulated X-ray scattering and evaluates the prospect for successful experiments at a present or future X-ray free electron laser (XFEL) facility.

  9. An in-vacuum diffractometer for resonant elastic soft x-ray scattering

    NARCIS (Netherlands)

    Hawthorn, D. G.; He, F.; Davis, H.; Achkar, A. J.; Zhang, J.; Sutarto, R.; Wadati, H.; Radi, A.; Wilson, T.; Wright, G.; Shen, K. M.; Geck, J.; Zhang, H.; Novak, V.; Sawatzky, G. A.; Venema, L.C.

    We describe the design, construction, and performance of a 4-circle in-vacuum diffractometer for resonant elastic soft x-ray scattering. The diffractometer, installed on the resonant elastic and inelastic x-ray scattering beamline at the Canadian Light Source, includes 9 in-vacuum motions driven by

  10. High energy x-ray reflectivity and scattering study from spectrum-x-gamma flight mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Budtz-Jørgensen, Carl; Frederiksen, P. Kk

    1993-01-01

    Line radiation from Fe K-alpha(1), Cu K-alpha(1), and Ag K-alpha(1) is used to study the high energy X-ray reflectivity and scattering behavior of flight-quality X-ray mirrors having various Al substrates. When both the specular and the scattered radiation are integrated, near theoretical...

  11. Densitometry and temperature measurement of combustion gas by X-ray Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hiroshi, E-mail: sakuraih@gunma-u.ac.jp [Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Kawahara, Nobuyuki [Okayama University, Tsushima-Naka 3, Okayama 700-8530 (Japan); Itou, Masayoshi [Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Tomita, Eiji [Okayama University, Tsushima-Naka 3, Okayama 700-8530 (Japan); Suzuki, Kosuke [Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Sakurai, Yoshiharu [Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan)

    2016-02-17

    Measurement of combustion gas by high-energy X-ray Compton scattering is reported. Measurement of combustion gas by high-energy X-ray Compton scattering is reported. The intensity of Compton-scattered X-rays has shown a position dependence across the flame of the combustion gas, allowing us to estimate the temperature distribution of the combustion flame. The energy spectra of Compton-scattered X-rays have revealed a significant difference across the combustion reaction zone, which enables us to detect the combustion reaction. These results demonstrate that high-energy X-ray Compton scattering can be employed as an in situ technique to probe inside a combustion reaction.

  12. Time Resolved X-Ray Scattering of molecules in Solution

    DEFF Research Database (Denmark)

    Brandt van Driel, Tim

    of bringing the data from measurement to analysis. Bridging the experimental design and challenges of the experiments from X-ray synchrotrons to the newly available X-ray Free Electron Laser sources (XFEL).LCLS in California is the first XFEL to come online and delivers intense 30fs X-ray pulses, orders...... in the purpose built CSPAD detector is presented and applied to the data to highlight the relevance of this work. Thereby showing the ability to capture a molecular movie on the sub-ps time-scale....

  13. X-ray, neutron, and electron scattering. Report of a materials sciences workshop

    Energy Technology Data Exchange (ETDEWEB)

    1977-08-01

    The ERDA Workshop on X-ray, Neutron, and Electron Scattering to assess needs and establish priorities for energy-related basic research on materials. The general goals of the Workshop were: (1) to review various energy technologies where x-ray, neutron, and electron scattering techniques might make significant contributions, (2) to identify present and future materials problems in the energy technologies and translate these problems into requirements for basic research by x-ray, neutron, and electron scattering techniques, (3) to recommend research areas utilizing these three scattering techniques that should be supported by the DPR Materials Sciences Program, and (4) to assign priorities to these research areas.

  14. A compact high vacuum heating chamber for in-situ x-ray scattering studies

    Energy Technology Data Exchange (ETDEWEB)

    Bertram, F.; Deiter, C.; Pflaum, K.; Seeck, O. H. [Hamburger Synchrotronstrahlungslabor am Deutschen Elektronen-Synchrotron, Notkestr. 85, 22607 Hamburg (Germany)

    2012-08-15

    A very compact multi purpose high vacuum heating chamber for x-ray scattering techniques was developed. The compact design allows the chamber to be installed on high precision diffractometers which usually cannot support heavy and/or large equipment. The chamber is covered by a Be dome allowing full access to the hemisphere above the sample which is required for in-plane grazing incident x-ray diffraction and out-off plane wide angle x-ray diffraction.

  15. Influence of X-ray scatter radiation on image quality in Digital Breast Tomosynthesis (DBT)

    Science.gov (United States)

    Rodrigues, M. J.; Di Maria, S.; Baptista, M.; Belchior, A.; Afonso, J.; Venâncio, J.; Vaz, P.

    2017-11-01

    Digital breast tomosynthesis (DBT) is a quasi-three-dimensional imaging technique that was developed to solve the principal limitation of mammography, namely the overlapping tissue effect. This issue in standard mammography (SM) leads to two main problems: low sensitivity (difficulty to detect lesions) and low specificity (non-negligible percentage of false positives). Although DBT is now being introduced in clinical practice the features of this technique have not yet been fully and accurately assessed. Consequently, optimization studies in terms of choosing the most suitable parameters which maximize image quality according to the known limits of breast dosimetry are currently performing. In DBT, scatter radiation can lead to a loss of contrast and to an increase of image noise by reducing the signal-to-difference-noise ratio (SDNR) of a lesion. Moreover the use of an anti-scatter grid is a concern due to the low exposure of the photon flux available per projection. For this reason the main aim of this study was to analyze the influence of the scatter radiation on image quality and the dose delivered to the breast. In particular a detailed analysis of the scatter radiation on the optimal energy that maximizes the SDNR was performed for different monochromatic energies and voltages. To reach this objective the PenEasy Monte Carlo (MC) simulation tool imbedded in the general-purpose main program PENELOPE, was used. After a successful validation of the MC model with measurements, 2D projection images of primary, coherent and incoherent photons were obtained. For that, a homogeneous breast phantom (2, 4, 6, 8 cm) with 25%, 50% and 75% glandular compositions was used, including a 5 mm thick tumor. The images were generated for each monochromatic X-ray energies in the range from 16 keV to 32 keV. For each angular projection considered (25 angular projections covering an arc of 50°) the scatter-to-primary ratio (SPR), the mean glandular dose (MGD) and the signal

  16. Magnetic nanoparticles studied by small angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cristiano Luis Pinto [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica. Grupo de Fluidos Complexos; Antonel, Soledad; Negri, Martin [Universidad de Buenos Aires (UBA) (Argentina). Facultad de Ciencias Exactas y Naturales. Dept. de Quimica Inorganica, Analitica y Quimica Fisica

    2011-07-01

    nanoparticles are very interesting because they exhibit magnetic (ferromagnetic) and electrical properties in the same material. Then, the nickel nanoparticles could be used for the development of electroelastic materials. In this case, the electrical conductivity of the material can be strongly dependent on the applied magnetic field, for example the case of nickel metal nanoparticles dispersed in a polymer, resulting in an anisotropic material with combined piezomagnetic and piezoelectric properties. In order to investigate the structural characteristics of cobalt-iron oxides and nickel nanoparticles, powder samples of those magnetic materials were studied by Small-Angle X-Ray Scattering. As will be shown, from the analysis and modeling of the scattering data, structural information could be obtained, enabling a detailed description of the structural properties of the studied samples which could be directly correlated to the magnetic properties. (author)

  17. Preliminary design of a zone plate based hard X-ray monochromatic diffraction nanoprobe for materials studies at APS

    Science.gov (United States)

    Cai, Zhonghou; Liu, Wenjun; Tischler, Jonathan Z.; Shu, Deming; Xu, Ruqing; Schmidt, Oliver

    2013-09-01

    Aiming at studies of the micro/nano-structures of a broad range materials and electronic devices, Advance Photon Source (APS) is developing a dedicated diffraction nanoprobe (DNP) beamline for the needs arising from a multidiscipline research community. As a part of the APS Upgrade Project, the planed facility, named Sub-micron 3-D Diffraction (S3DD) beamline1, integrates the K-B mirror based polychromatic Laue diffraction and the Fresnel zone-plate based monochromatic diffraction techniques that currently support 3D/2D microdiffraction programs at the 34-ID-E and 2-ID-D of the APS, respectively. Both diffraction nanoprobes are designed to have a 50-nm or better special resolution. The zone-plate based monochromatic DNP has been preliminarily designed and will be constructed at the sector 34-ID. It uses an APS-3.0-cm period or APS-3.3-cm period undulator, a liquid-nitrogen cooled mirror as its first optics, and a water cooled small gap silicon double-crystal monochromator with an energy range of 5-30 keV. A set of zone plates have been designed to optimize for focusing efficiency and the working distance based on the attainable beamline length and the beam coherence. To ensure the nanoprobe performance, high stiffness and high precision flexure stage systems have been designed or demonstrated for optics mounting and sample scanning, and high precision temperature control of the experimental station will be implemented to reduce thermal instability. Designed nanoprobe beamline has a good management on thermal power loading on optical components and allows high degree of the preservation of beam brilliance for high focal flux and coherence. Integrated with variety of X-ray techniques, planed facility provides nano-XRD capability with the maximum reciprocal space accessibility and allows micro/nano-spectroscopy studies with K-edge electron binding energies of most elements down to Vanadium in the periodic table. We will discuss the preliminary design of the zone

  18. X-ray scattered halo around IGR J17544–2619

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Junjie; Ling, Zhixing; Zhang, Shuang-Nan, E-mail: zhangsn@ihep.ac.cn [National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2014-04-10

    X-ray photons coming from an X-ray point source not only arrive at the detector directly, but also can be strongly forward-scattered by the interstellar dust along the line of sight (LOS), leading to a detectable diffuse halo around the X-ray point source. The geometry of small-angle X-ray scattering is straightforward, namely, the scattered photons travel longer paths and thus arrive later than the unscattered ones; thus, the delay time of X-ray scattered halo photons can reveal information of the distances of the interstellar dust and the point source. Here we present a study of the X-ray scattered halo around IGR J17544–2619, which is one of the so-called supergiant fast X-ray transients. IGR J17544–2619 underwent a striking outburst when observed with Chandra on 2004 July 3, providing a near δ-function light curve. We find that the X-ray scattered halo around IGR J17544–2619 is produced by two interstellar dust clouds along the LOS. The one that is closer to the observer gives the X-ray scattered halo at larger observational angles, whereas the farther one, which is in the vicinity of the point source, explains the halo with a smaller angular size. By comparing the observational angle of the scattered halo photons with that predicted by different dust grain models, we are able to determine the normalized dust distance. With the delay times of the scattered halo photons, we can determine the point source distance, given a dust grain model. Alternatively, we can discriminate between the dust grain models, if the point source distance is known independently.

  19. Mapping strain fields in ultrathin bonded Si wafers by x-ray scattering

    DEFF Research Database (Denmark)

    Nielsen, Mourits; Poulsen, Mette; Bunk, Oliver

    2002-01-01

    X-ray scattering reveals the atomic displacements arising from rotational misalignment in ultrathin silicon bonded wafers. For a 4.3 nm top wafer, the strain field penetrates from the bonded interface to the surface and produces distinctive finite-size oscillations in x-ray data. Analytical...... calculations permit the atomic displacements throughout the thin top wafer to be modeled....

  20. X-ray scattering studies of lanthanides magnetism

    DEFF Research Database (Denmark)

    McMorrow, D.; Bohr, Jakob; Gibbs, D.

    1999-01-01

    Interest in the applications of X-ray synchrotron radiation has grown rapidly during the last decade. At the present time, intense, ultra-bright synchrotron radiation is available on a routine basis from third-generation sources located in Europe (ESRF), North America (APS) and Japan (Spring8...

  1. A Monte Carlo simulation of scattering reduction in spectral x-ray computed tomography

    DEFF Research Database (Denmark)

    Busi, Matteo; Olsen, Ulrik Lund; Bergbäck Knudsen, Erik

    2017-01-01

    In X-ray computed tomography (CT), scattered radiation plays an important role in the accurate reconstruction of the inspected object, leading to a loss of contrast between the different materials in the reconstruction volume and cupping artifacts in the images. We present a Monte Carlo simulation...... photons, enabling spectral analysis of X-ray images. This technique is useful to extract efficiently more information on energy dependent quantities (e.g. mass attenuations coefficients) and study matter interactions (e.g. X-ray scattering, photoelectric absorption, etc...). Having a good knowledge...... of the spectral distribution of the scattered X-rays is fundamental to establish methods attempting to correct for it. The simulations are validated by real measurements using a CdTe spectral resolving detector (Multix ME-100). We observed the effect of the scattered radiation on the image reconstruction...

  2. Small-Angle X-ray Scattering Screening Complements Conventional Biophysical Analysis

    DEFF Research Database (Denmark)

    Tian, Xinsheng; Langkilde, Annette Eva; Thorolfsson, Matthias

    2014-01-01

    introduce small-angle X-ray scattering (SAXS) to characterize antibody solution behavior, which strongly complements conventional biophysical analysis. First, we apply a variety of conventional biophysical techniques for the evaluation of structural, conformational, and colloidal stability and report...

  3. Low-energy shelf response in thin energy-dispersive X-ray detectors from Compton scattering of hard X-rays

    Science.gov (United States)

    Michel-Hart, N.; Elam, W. T.

    2017-08-01

    Silicon drift detectors have been successfully employed in both soft and hard X-ray spectroscopy. The response function to incident radiation at soft X-ray levels has been well studied and modeled, but less research has been published on response functions for these detectors to hard X-ray input spectra above 20 keV. When used with hard X-ray sources a significant low energy, non-peak response exists which can adversely affect detection limits for lighter elements in, for example, X-ray fluorescence spectroscopy. We present a numerical model that explains the non-peak response function of silicon drift detectors to hard X-rays based on incoherent Compton scattering within the detector volume. Experimental results are presented and numerically compared to model results.

  4. Inelastic X-ray scattering of Sm-filled Skutterudite compounds

    Energy Technology Data Exchange (ETDEWEB)

    Tsutsui, S. [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198 (Japan)]. E-mail: satoshi@spring8.or.jp; Kobayashi, H. [Graduate school of Materials Science, University of Hyogo, Kamigori, Hyogo 678-1297 (Japan); CREST, Japan Science and Technology Corporation, Kawaguchi, Saitama 332-0012 (Japan); Baron, A.Q.R. [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198 (Japan); RIKEN, SPring-8, Sayo, Hyogo 679-5148 (Japan); Sutter, J.P. [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198 (Japan); Yoda, Y. [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198 (Japan); CREST, Japan Science and Technology Corporation, Kawaguchi, Saitama 332-0012 (Japan); Onodera, H. [Graduate School of Science, Tohoku University, Sendai, Miyagi 980-8578 (Japan); Kikuchi, D. [Department of Physics, Tokyo Metropolitan University, Hachioji, Tokyo 192-0937 (Japan); Sugawara, H. [Faculty of Integrated Arts and Sciences, University of Tokushima, Tokushima, Tokushima 770-8502 (Japan); Sato, H. [Department of Physics, Tokyo Metropolitan University, Hachioji, Tokyo 192-0937 (Japan); Sekine, C. [Department of Electronic and Electric Engineering, Muroran Institute of Technology, Muroran, Hokkaido 050-8585 (Japan); Shirotani, I. [Department of Electronic and Electric Engineering, Muroran Institute of Technology, Muroran, Hokkaido 050-8585 (Japan)

    2007-03-15

    We have carried out inelastic X-ray scattering and {sup 149}Sm nuclear resonant inelastic scattering of SmRu{sub 4}P{sub 12} to investigate its metal-insulator transition. We have not observed any significant change in both inelastic X-ray scattering spectra and nuclear resonant inelastic scattering spectra at the transition temperature. In spite of the proposal of the Fermi surface nesting at q =(1 0 0) by the recent band calculation, the anomalies correlated with the metal-insulator transition were not found in the inelastic X-ray scattering spectrum at the longitudinal zone boundary along the [1 0 0] direction. The results of {sup 149}Sm nuclear resonant inelastic scattering also suggest that the Sm vibration modes are not correlated with the metal-insulator transition.

  5. X-ray scattering and the chemical bond in N2 and CN

    NARCIS (Netherlands)

    Groenewegen, P.P.M.; Zeevalkink, J.; Feil, D.

    1971-01-01

    X-ray scattering from the chemical bond within N2 and CN- has been studied in detail. Differences in scattering from these systems, derived from bonding and non-bonding models, are characterized by R values of ~ 0.04. Partitioning of the scattering into core and valence electron parts clearly

  6. Low-lying optical modes in filled skutterudites using inelastic x-ray scattering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tsutsui, S [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198 (Japan); Kobayashi, H [Graduate School of Materials Science, University of Hyogo, Kamigori, Hyogo 678-1298 (Japan); Sutter, J P [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198, Japan (Japan); Baron, A R [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198 (Japan); Hasegawa, T [Graduate School of Integrated Arts and Sciences, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8527 (Japan); Ogita, N [Graduate School of Integrated Arts and Sciences, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8527 (Japan); Udagawa, M [Graduate School of Integrated Arts and Sciences, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8527 (Japan); Yoda, Y [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo 679-5198 (Japan); Sekine, C [Department of Electric and Electronic Engineering, Muroran Institute of Technology, Muroran, Hokkaido 050-8585 (Japan); Shirotani, I [Department of Electric and Electronic Engineering, Muroran Institute of Technology, Muroran, Hokkaido 050-8585 (Japan); Kikuchi, D [Department of Physics, Tokyo Metropolitan University, Hachioji, Tokyo 192-0937 (Japan); Sugawara, H [Faculty of Integrated Arts and Sciences, University of Tokushima, Tokushima, Tokushima 770-8502 (Japan); Sato, H [Department of Physics, Tokyo Metropolitan University, Hachioji, Tokyo 192-0937 (Japan)

    2007-12-15

    We have carried out high resolution inelastic x-ray scattering and {sup 149}Sm nuclear resonant inelastic scattering of a skutterudite SmRu{sub 4}P{sub 12}. The inelastic x-ray scattering spectra and dispersion show q-dependence and zone-dependence except for the modes lying at 9 meV. The dispersionless modes, which are zone-independent, are observed at 9 meV. The energy of this mode agrees with that obtained by {sup 149}Sm nuclear resonant inelastic scattering. The dispersion suggests the presence of strong hybridization between low-lying optical mode at 9 meV and acoustic ones.

  7. Charge and orbital ordered states studied by using x-ray anomalous scattering terms

    CERN Document Server

    Nakao, H

    2002-01-01

    Recently, the studies utilizing anomalous scattering term of atomic scattering factor near absorption edge, so called x-ray anomalous scattering and resonant x-ray scattering, have been rapidly developed. This technique has especially contributed to the determination of the charge-orbital ordered structure in strongly correlated electron system. In this paper, we present the typical examples - the charge ordering of V sup 4 sup + and V sup 5 sup + in NaV sub 2 O sub 5 and the antiferro-quadrupole ordering (orbital ordering) of Ge sup 3 sup + ions in CeB sub 6 (author)

  8. Vibrational effects in x-ray absorption and resonant inelastic x-ray scattering using a semiclassical scheme

    Science.gov (United States)

    Ljungberg, Mathias P.

    2017-12-01

    A method is presented for describing vibrational effects in x-ray absorption spectroscopy and resonant inelastic x-ray scattering (RIXS) using a combination of the classical Franck-Condon (FC) approximation and classical trajectories run on the core-excited state. The formulation of RIXS is an extension of the semiclassical Kramers-Heisenberg formalism of Ljungberg et al. [Phys. Rev. B 82, 245115 (2010), 10.1103/PhysRevB.82.245115] to the resonant case, retaining approximately the same computational cost. To overcome difficulties with connecting the absorption and emission processes in RIXS, the classical FC approximation is used for the absorption, which is seen to work well provided that a zero-point-energy correction is included. In the case of core-excited states with dissociative character, the method is capable of closely reproducing the main features for one-dimensional test systems, compared to the quantum-mechanical formulation. Due to the good accuracy combined with the relatively low computational cost, the method has great potential of being used for complex systems with many degrees of freedom, such as liquids and surface adsorbates.

  9. Resonant X-ray scattering studies of concentrated aqueous solutions

    CERN Document Server

    Ramos, S

    2001-01-01

    structure of the three cations is also presented in this thesis. This work illustrates one of the main advantages of RXD: the possibility of carrying out systematic structural studies on all elements with atomic number greater than 28 (Ni). Finally, a critical discussion on the actual stage of development of RXD is presented. The results shown offer evidence of the future prospects of the technique and justify further efforts to develop it to the level of reliability and ease of use that NDIS has reached after more than three decades of development. The microscopic structure of concentrated aqueous electrolyte solutions has been studied by resonant X-ray diffraction (RXD). This technique provides a method for the measurement of the structure around a specific atom or ion in solution. In that sense, RXD is the X-ray equivalent of neutron diffraction with isotopic substitution (NDIS). The use of RXD as an alternative to NDIS has been considered of interest for some time; it is potentially one of the best method...

  10. X-ray scattering for the determination of fat content in dairy products

    Science.gov (United States)

    Elshemey, Wael M.

    2011-07-01

    The scattering of X-rays from biological samples has been shown to produce characteristic profiles, which depend on their molecular structure. The highly ordered fat molecules in an adipose tissue result in a relatively sharp scattering peak at 1.1 nm -1 with a scattering profile, which is considerably different from the scattering profile of a water-rich tissue. The latter is characterized by a broad scattering peak at about 1.6 nm -1. A biological sample consisting of a mixture of both adipose and a water-rich tissue is expected to show a scattering profile, which is directly linked to the relative contribution of each component and would reflect the percentage by volume of each component in the mixture. In this work, X-ray scattering profiles of a number of dairy products and water are measured. The values of two selected X-ray scattering characterization parameters ( I1/ I2% and areas A1/ A2% of the scattering peaks at 1.1 and 1.6 nm -1, respectively) are plotted against the fat content of each of the measured dairy samples. Results show a strong linear dependence of each of the X-ray scattering parameters and the fat content of the investigated dairy products. These results suggest a possible use of such technique as a new, simple and straight forward method for determination of fat content of dairy products that would join and support the currently available techniques.

  11. X-ray coherent scattering tomography of textured material (Conference Presentation)

    Science.gov (United States)

    Zhu, Zheyuan; Pang, Shuo

    2017-05-01

    Small-angle X-ray scattering (SAXS) measures the signature of angular-dependent coherently scattered X-rays, which contains richer information in material composition and structure compared to conventional absorption-based computed tomography. SAXS image reconstruction method of a 2 or 3 dimensional object based on computed tomography, termed as coherent scattering computed tomography (CSCT), enables the detection of spatially-resolved, material-specific isotropic scattering signature inside an extended object, and provides improved contrast for medical diagnosis, security screening, and material characterization applications. However, traditional CSCT methods assumes materials are fine powders or amorphous, and possess isotropic scattering profiles, which is not generally true for all materials. Anisotropic scatters cannot be captured using conventional CSCT method and result in reconstruction errors. To obtain correct information from the sample, we designed new imaging strategy which incorporates extra degree of detector motion into X-ray scattering tomography for the detection of anisotropic scattered photons from a series of two-dimensional intensity measurements. Using a table-top, narrow-band X-ray source and a panel detector, we demonstrate the anisotropic scattering profile captured from an extended object and the reconstruction of a three-dimensional object. For materials possessing a well-organized crystalline structure with certain symmetry, the scatter texture is more predictable. We will also discuss the compressive schemes and implementation of data acquisition to improve the collection efficiency and accelerate the imaging process.

  12. LIGHT SOURCE: A simulation study of Tsinghua Thomson scattering X-ray source

    Science.gov (United States)

    Tang, Chuan-Xiang; Li, Ren-Kai; Huang, Wen-Hui; Chen, Huai-Bi; Du, Ying-Chao; Du, Qiang; Du, Tai-Bin; He, Xiao-Zhong; Hua, Jian-Fei; Lin, Yu-Zhen; Qian, Hou-Jun; Shi, Jia-Ru; Xiang, Dao; Yan, Li-Xin; Yu, Pei-Cheng

    2009-06-01

    Thomson scattering X-ray sources are compact and affordable facilities that produce short duration, high brightness X-ray pulses enabling new experimental capacities in ultra-fast science studies, and also medical and industrial applications. Such a facility has been built at the Accelerator Laboratory of Tsinghua University, and upgrade is in progress. In this paper, we present a proposed layout of the upgrade with design parameters by simulation, aiming at high X-ray pulses flux and brightness, and also enabling advanced dynamics studies and applications of the electron beam. Design and construction status of main subsystems are also presented.

  13. International Conference on Surface X-ray and Neutron Scattering (SXNS-11)

    Energy Technology Data Exchange (ETDEWEB)

    Michael J. Bedzyk

    2011-06-17

    The 11th International Surface X-ray and Neutron Scattering (SXNS) Conference was held on July 13-17, 2010, on the Northwestern University (NU) campus, in Evanston Illinois and hosted by the NU Materials Research Science and Engineering Center. This biennial conference brought together a community of 164 attendees from 16 countries. The field now makes use of a broad range of new experimental capabilities that have been made possible through the development of increasingly brilliant X-ray and neutron sources around the world, including third generation synchrotron sources, neutron reactor and spallation sources, as well as the recent development of X-ray lasers.

  14. Soft X-ray production by photon scattering in pulsating binary neutron star sources

    Science.gov (United States)

    Bussard, R. W.; Meszaros, P.; Alexander, S.

    1985-01-01

    A new mechanism is proposed as a source of soft (less than 1 keV) radiation in binary pulsating X-ray sources, in the form of photon scattering which leaves the electron in an excited Landau level. In a plasma with parameters typical of such sources, the low-energy X-ray emissivity of this mechanism far exceeds that of bremsstrahlung. This copious source of soft photons is quite adequate to provide the seed photons needed to explain the power-law hard X-ray spectrum by inverse Comptonization on the hot electrons at the base of the accretion column.

  15. A Monte Carlo simulation of scattering reduction in spectral x-ray computed tomography

    Science.gov (United States)

    Busi, Matteo; Olsen, Ulrik L.; Knudsen, Erik B.; Frisvad, Jeppe R.; Kehres, Jan; Christensen, Erik D.; Khalil, Mohamad; Haldrup, Kristoffer

    2017-08-01

    In X-ray computed tomography (CT), scattered radiation plays an important role in the accurate reconstruction of the inspected object, leading to a loss of contrast between the different materials in the reconstruction volume and cupping artifacts in the images. We present a Monte Carlo simulation tool for spectral X-ray CT to predict the scattered radiation generated by complex samples. An experimental setup is presented to isolate the energy distribution of scattered radiation. Spectral CT is a novel technique implementing photon-counting detectors able to discriminate the energy of incoming photons, enabling spectral analysis of X-ray images. This technique is useful to extract efficiently more information on energy dependent quantities (e.g. mass attenuations coefficients) and study matter interactions (e.g. X-ray scattering, photoelectric absorption, etc...). Having a good knowledge of the spectral distribution of the scattered X-rays is fundamental to establish methods attempting to correct for it. The simulations are validated by real measurements using a CdTe spectral resolving detector (Multix ME-100). We observed the effect of the scattered radiation on the image reconstruction, becoming relevant in the energy range where the Compton events are dominant (i.e. above 50keV).

  16. A novel method for resonant inelastic soft X-ray scattering via photoelectron spectroscopy detection.

    Science.gov (United States)

    Dakovski, Georgi L; Lin, Ming Fu; Damiani, Daniel S; Schlotter, William F; Turner, Joshua J; Nordlund, Dennis; Ogasawara, Hirohito

    2017-11-01

    A method for measuring resonant inelastic X-ray scattering based on the conversion of X-ray photons into photoelectrons is presented. The setup is compact, relies on commercially available detectors, and offers significant flexibility. This method is demonstrated at the Linac Coherent Light Source with ∼0.5 eV resolution at the cobalt L3-edge, with signal rates comparable with traditional grating spectrometers.

  17. Superhydrophobic surfaces allow probing of exosome self organization using X-ray scattering

    KAUST Repository

    Accardo, Angelo

    2013-01-01

    Drops of exosome dispersions from healthy epithelial colon cell line and colorectal cancer cells were dried on a superhydrophobic PMMA substrate. The residues were studied by small- and wide-angle X-ray scattering using both a synchrotron radiation micrometric beam and a high-flux table-top X-ray source. Structural differences between healthy and cancerous cells were detected in the lamellar lattices of the exosome macro-aggregates. © 2013 The Royal Society of Chemistry.

  18. Resonant X-ray Raman scattering on molecules: A benchmark study on HCl

    Energy Technology Data Exchange (ETDEWEB)

    Carniato, Stephane [UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France); CNRS, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France); Taieb, Richard, E-mail: richard.taieb@upmc.f [UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France); CNRS, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France); Journel, Loic; Guillemin, Renaud [UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France); CNRS, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France); Stolte, Wayne C.; Lindle, Dennis W. [Department of Chemistry, University of Nevada, Las Vegas, NV 89154-4003 (United States); Gel' mukhanov, Faris [Theoretical Chemistry, Roslagstullsbacken 15, Royal Institute of Technology, S-106 91 Stockholm (Sweden); Simon, Marc [UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France); CNRS, UMR 7614, Laboratoire de Chimie Physique Matiere et Rayonnement, F-75005 Paris (France)

    2010-08-15

    Resonant X-ray Raman scattering is a powerful tool to study molecular dynamics and subtle chemical effects like the molecular field beyond vibrational and lifetime limitations. Using this technique in the tender X-ray region, gas phase HCl is studied as a benchmark molecule for other compounds like freons, which play an important role in physical-chemical properties of the ozone layer of atmosphere.

  19. Temperature measurement through detailed balance in X-ray Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Doppner, T; Landen, O L; Lee, H J; Neumayer, P; Regan, S P; Glenzer, S H

    2009-02-02

    The plasma conditions in isochorically heated beryllium are measured by x-ray Thomson scattering in the collective regime with a Cl Ly-{alpha} x-ray source at 2.96 keV. In addition to the down-shifted plasmon shape which provides electron density and temperature information, an up-shifted plasmon signal is observed allowing a model independent determination of the plasma temperature from the detailed balance relation.

  20. Optimization of the genetic algorithm of jointly fitting different types of X-ray scattering curves

    Energy Technology Data Exchange (ETDEWEB)

    Sutyrin, A. G.; Imamov, R. M., E-mail: imamov@ns.crys.ras.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2011-01-15

    A method for jointly processing X-ray scattering data of different types is developed. It is shown that, by optimizing the genetic algorithm of the joint solution of the inverse problem of X-ray diffractometry and reflectometry, one can reduce the amount of calculations and reliably determine the parameters of layers in the structure under study, even when the information about them is a priori limited.

  1. Toroidal silicon polarization analyzer for resonant inelastic x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Xuan [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008-5252 (United States); Key Laboratory of Multi-scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714 (China); Casa, Diego; Kim, Jungho; Gog, Thomas [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Li, Chengyang [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008-5252 (United States); Department of Physics, South University of Science and Technology of China, Shenzhen 518055 (China); Burns, Clement [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008-5252 (United States)

    2016-08-15

    Resonant Inelastic X-ray Scattering (RIXS) is a powerful probe for studying electronic excitations in materials. Standard high energy RIXS measurements do not measure the polarization of the scattered x-rays, which is unfortunate since it carries information about the nature and symmetry of the excitations involved in the scattering process. Here we report the fabrication of thin Si-based polarization analyzers with a double-concave toroidal surface, useful for L-edge RIXS studies in heavier atoms such as the 5-d transition metals.

  2. X-ray resonant Raman scattering in the rare earths

    NARCIS (Netherlands)

    van Veenendaal, M.A.; Carra, P.; Thole, B.T

    1996-01-01

    This paper develops a theory of resonant Raman scattering within the framework of a localized model. Expressions for the scattering amplitude and cross section are derived by employing the methods of spherical-tensor analysis. a simple factorization is obtained for the geometrical (angular

  3. Technical Development of Profile Measurement for the Soft X-Ray Via Compton Backward Scattering

    CERN Document Server

    Saito, Taku; Hayano, Hitoshi; Hidume, Kentaro; Kashiwagi, Shigeru; Kuroda, Ryunosuke; Minamiguchi, Shuichi; Oshima, Akihiro; Ueyama, Daisuke; Urakawa, Junji; Washio, Masakazu

    2005-01-01

    A compact X-ray source is called for such various fields as material development, biological science, and medical treatment. At Waseda University, we have already succeeded to generate the soft X-ray of the wavelength within so-called water window region (250-500eV) via Compton backward scattering between 1047nm Nd:YLF laser and 4.2MeV high quality electron beam. Although this method equips some useful characters, e.g. high intensity, short pulse, energy variableness, etc, the X-ray generating system is compact enough to fit in tabletop size. In the next step, there rises two principal tasks, that is, to make the soft X-ray intensity higher, and to progress X-ray profile measurement techniques as preliminary experiments for biomicroscopy. Specifically, we utilize two-pass amp for the former, and irradiate X-ray to a resist film which is previously exposed by UV lamp or get images with X-ray CCD for the latter. In this conference, we will show the experimental results and some future plans.

  4. The Operation Modes of Kharkov X-Ray Generator Based on Compton Scattering NESTOR

    Energy Technology Data Exchange (ETDEWEB)

    Bulyak, E.V.; Gladkikh, P.; Karnaukhov, I.M.; Mytsykov, A.; Shcherbakov, A.A.; Zelinsky, A.Y.; /Kharkov, KIPT; Tatchyn, R.; /SLAC, SSRL

    2005-05-09

    The results of theoretical and numerical considerations of linear Compton scattering are used to evaluate characteristics of X-rays produced by collision between a low emittance electron beam and intensive laser light in an X-ray generator NESTOR of NSC KIPT. Two main generation modes have been under consideration at preliminary NESTOR design. There are the operation mode for medicine 33.4 keV X-rays production using 43 Mev electron beam and Nd:YAG laser beam and higher energy X-rays production mode providing X-rays with energy up to 900 keV with 225 MeV electron beam and Nd:YAG laser beam. It was supposed to use an optical cavity for laser beam accumulation of about 2.6 m long and an interaction angle of about 3{sup o} in both operation modes. A few more operation modes provide possibility to expand operation range of NESTOR. Using interaction angle 10{sup o} and 150{sup o} along with optical resonator of 42 cm long and the second mode of laser light it is possible to produce X-rays in energy range from a few keV till 1.5 MeV. The intensity and spectral brightness of the X-rays is expected to be {approx} 10{sup 13} phot/s and {approx}10{sup 13} phot/s/mm{sup 2}/mrad{sup 2}/0.1%BW respectively.

  5. X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT

    Directory of Open Access Journals (Sweden)

    Sorapong Aootaphao

    2016-01-01

    Full Text Available Soft tissue images from portable cone beam computed tomography (CBCT scanners can be used for diagnosis and detection of tumor, cancer, intracerebral hemorrhage, and so forth. Due to large field of view, X-ray scattering which is the main cause of artifacts degrades image quality, such as cupping artifacts, CT number inaccuracy, and low contrast, especially on soft tissue images. In this work, we propose the X-ray scatter correction method for improving soft tissue images. The X-ray scatter correction scheme to estimate X-ray scatter signals is based on the deconvolution technique using the maximum likelihood estimation maximization (MLEM method. The scatter kernels are obtained by simulating the PMMA sheet on the Monte Carlo simulation (MCS software. In the experiment, we used the QRM phantom to quantitatively compare with fan-beam CT (FBCT data in terms of CT number values, contrast to noise ratio, cupping artifacts, and low contrast detectability. Moreover, the PH3 angiography phantom was also used to mimic human soft tissues in the brain. The reconstructed images with our proposed scatter correction show significant improvement on image quality. Thus the proposed scatter correction technique has high potential to detect soft tissues in the brain.

  6. X-ray Thomson scattering for partially ionized plasmas including the effect of bound levels

    CERN Document Server

    Nilsen, J; Cheng, K T

    2013-01-01

    X-ray Thomson scattering is being developed as a method to measure the temperature, electron density, and ionization state of high energy density plasmas such as those used in inertial confinement fusion. Most experiments are currently done at large laser facilities that can create bright X-ray sources, however the advent of the X-ray free electron laser (X-FEL) provides a new bright source to use in these experiments. One challenge with X-ray Thomson scattering experiments is understanding how to model the scattering for partially ionized plasmas in order to include the contributions of the bound electrons in the scattered intensity. In this work we take the existing models of Thomson scattering that include elastic ion-ion scattering and the electron-electron plasmon scattering and add the contribution of the bound electrons in the partially ionized plasmas. We validated our model by analyzing existing beryllium experimental data. We then consider several higher Z materials such as Cr and predict the existe...

  7. X-ray Scattering Techniques for Characterization of Nanosystems in Lifescience

    Energy Technology Data Exchange (ETDEWEB)

    Saw, C K

    2005-04-11

    The intent of this chapter is to provide the basics of using x-ray diffraction techniques in order to obtain information on the structure and morphology of the nanosystems, and also to point out some of its strengths and weaknesses when compare to other characterization techniques. X-ray scattering examines over a wide range of density domains from a tenth to a thousandth angstrom. Essentially, this covers a whole range of condensed matter, including the structure and morphology of nanosystems, particularly useful for examining nanostructures in lifescience. This range of domain size requires both the wide-angle x-ray scattering (WAXS) and small-angle (SAXS) x-ray scattering techniques. Roughly WAXS covers from 2 nm down, and SAXS covers from .5 nm to 100 nm and possibly 1,000 nm for a finely tuned instrument. Brief theoretical description of both WAXS and SAXS will be given in this chapter. WAXS, by itself is a powerful technique in providing information on the crystallographic structure or lack of structure, atomic positions and sizes in a unit cell, to some extend, chemical compositions and as well as chemical stoichiometry. Examples of such experiments will also be given. In order to be able to describe the technique of x-ray scattering, some historical and theoretical background will be given in the hope of making this subject interesting and simple.

  8. Experimental elucidation: microscopic mechanism of resonant X-ray scattering in manganite films

    CERN Document Server

    Ohsumi, H; Kiyama, T

    2003-01-01

    Resonant X-ray scattering experiments have been performed on perovskite manganite La sub 0 sub . sub 5 Sr sub 0 sub . sub 5 MnO sub 3 thin films, which are grown on three distinct perovskite with a coherent epitaxial strain and have a forced ferro-type orbital ordering of Mn 3d orbitals. Using an interference technique, we have successfully observed the resonant X-ray scattering signal from the system having the ferro-type orbital ordering and also revealed the energy scheme of Mn 4p bands. For the forced ferro-type orbital ordering system, the present results evidence that the resonant X-ray scattering signal originates from the band structure effect due to the Jahn-Teller distortion of a MnO sub 6 octahedron, and not from the Coulomb interaction between 3d and 4p electrons. (author)

  9. Electronic Excitations in Vanadium Oxide Phthalocyanine Studied via Resonant Soft X-ray Emission and Resonant Inelastic X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Zhang,Y.; Wang, S.; Learmonth, T.; Plucinski, L.; Matsuura, A.; Bernardis, S.; ODonnell, C.; Downes, J.; Smith, K.

    2005-01-01

    The electronic structure of the organic semiconductor vanadium oxide phthalocyanine has been studied using resonant inelastic X-ray scattering and X-ray emission spectroscopy. The vanadyl species in the films is shown to be highly localized, and good agreement between the measurements and a density functional calculation is obtained. Both dipole forbidden V 3d to V 3d*, and O 2p to V 3d* charge transfer transitions are observed, and explained in a local molecular orbital model.

  10. Characterizing the luminescence properties of LiF crystal imaging detectors using femtosecond soft X-ray monochromatic free electron laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    Pikuz, Tatiana; Faenov, Anatoly [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kizugawa, Kyoto 619-0215 (Japan); Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); Fukuda, Yuji; Kando, Masaki; Bolton, Paul [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kizugawa, Kyoto 619-0215 (Japan); Mitrofanov, Alexander [Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); Vinogradov, Alexander [P.N. Lebedev Physical Institute, Russian Academy of Science, Moscow 119991 (Russian Federation); Nagasono, Mitsuru; Tono, Kensuke; Ishikawa, Tetsuya [XFEL RIKEN, SPring-8, Hyogo 679-5198 (Japan); Ohashi, Haruhiko; Yabashi, Makina [XFEL RIKEN, SPring-8, Hyogo 679-5198 (Japan); Japan Synchrotron Radiation Research Institute, SPring-8, Hyogo 679-5198 (Japan); Senba, Yashinori; Togashi, Tadashi [Japan Synchrotron Radiation Research Institute, SPring-8, Hyogo 679-5198 (Japan)

    2012-12-15

    The monochromatic soft X-ray femtosecond pulses of the Free Electron Laser (FEL) with wavelengths of 17.2-61.5 nm were applied for measurements of optical features of point defects photoluminescence in LiF crystals. It was observed that peak of photoluminescence spectra appears near 530 nm and is associated with emission of F{sub 3}{sup +} centers. Our results suggest that a shortening of the applied laser pulses down to pico - or femtosecond duration causes redistribution of photolumi-nescence peak intensity from the red to the green part of the spectra and does not depend on the energy of EUV or X-ray photons. Dependence of peak intensity of photoluminescence spectra on the fluence of FEL radiation was measured. Even for relatively high fluencies a quenching phenomenon was not observed. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. X-ray microdiffraction of biominerals.

    Science.gov (United States)

    Tamura, Nobumichi; Gilbert, Pupa U P A

    2013-01-01

    Biominerals have complex and heterogeneous architectures, hence diffraction experiments with spatial resolutions between 500 nm and 10 μm are extremely useful to characterize them. X-ray beams in this size range are now routinely produced at many synchrotrons. This chapter provides a review of the different hard X-ray diffraction and scattering techniques, used in conjunction with efficient, state-of-the-art X-ray focusing optics. These include monochromatic X-ray microdiffraction, polychromatic (Laue) X-ray microdiffraction, and microbeam small-angle X-ray scattering. We present some of the most relevant discoveries made in the field of biomineralization using these approaches. © 2013 Elsevier Inc. All rights reserved.

  12. International workshop on resonant X-ray scattering in electrically-ordered systems

    Energy Technology Data Exchange (ETDEWEB)

    Collins, S.P.; Pettifer, R.F.; Laundy, D.; Ishida, K.; Kokubun, J.; Giles, C.; Yokaichiya, F.; Song, C.; Lee, K.B.; Ji, S.; Koo, J.; Park, Y.J.; Kim, J.Y.; Park, J.H.; Shin, H.J.; Rhyee, J.S.; Oh, B.H.; Cho, B.K.; Wilkins Stuart, B.; Paixao, J.A.; Caciuffo, R.; Javorsky, P.; Wastin, F.; Rebizant, J.; Detlefs, C.; Bernheoft, N.; Lander, G.H.; Bombardi, A.; Bergevin, F. de; Matteo, S. di; Paolasini, L.; Rodriguez-Carvajal, J.; Carretta, P.; Millet, P.; Caciuffo, R.; Goff, J.P.; Deen, P.P.; Lee, S.; Stunault, A.; Brown, S.; Mannix, D.; McIntyre, G.J.; Ward, R.C.C.; Wells, M.R.; Lorenzo, J.E.; Joly, Y.; Nazarenko, E.; Staub, U.; Srajer, G.; Haskel, D.; Choi, Y.; Lee, D.R.; Lang, J.C.; Meersschaut, J.; Jiang, J.S.; Bader, S.D.; Bouchenoire, L.; Brown, S.D.; Beesley, A.; Herring, A.; Thomas, M.; Thompson, P.; Langridge, S.; Stirling, W.G.; Mirone, A.; Lander, G.; Wilkins, S.; Ward, R.C.C.; Wells, M.R.; Zochowski, S.W.; Garcia, J.; Subias, G.; Blasco, J.; Sanchez, M.C.; Proietti, M.G.; Lovesey, S.W.; Dmitrienko, V.E.; Ovchinnikova, E.N.; Ishida, K.; Kokubun, J.; Kirfel, A.; Collins, S.P.; Laundy, D.; Oreshko, A.P.; Strange, P.; Horne, M.; Arola, E.; Winter, H.; Szotek, Z.; Temmerman, W.M.; Igarashi, J.; Usuda, M.; Takahashi, M.; Matteo, S. di; Bernhoeft, N.; Hill, J.P.; Lang, J.C.; McWhan, D.; Lee, D.R.; Haskel, D.; Srajer, G.; Hatton Peter, D.; Katsumata, K.; Braithwaite, D

    2004-07-01

    The research field of Resonant X-ray Scattering (RXS) has achieved tremendous progress in the last years. Nowadays RXS is rapidly becoming the crucial technique for investigating the subtleties of microscopic magnetism in systems where the ground state properties reflect a delicate balance between several different correlated processes. The aim of this workshop is to discuss present and future possibilities for RXS investigations of electronic order, including studies of charge, magnetic, and multipolar ordered states. The sessions will cover experimental and theoretical aspects of hard and soft X-ray resonant scattering from single crystals and thin films. This document gathers the summaries of the presentations.

  13. Dust scattering X-ray expanding rings around gamma-ray bursts

    OpenAIRE

    Mereghetti, S.; Tiengo, A.; Vianello, G.

    2006-01-01

    Scattering by dust grains in our Galaxy can produce X-ray halos, visible as expanding rings, around GRBs. This has been observed in three GRBs to date, allowing to derive accurate distances for the dust clouds as well as some constraints on the prompt GRB X-ray emission that was not directly observed. We developed a new analysis method to study dust scattering expanding rings and have applied it to all the XMM-Newton and Swift/XRT follow-up observations of GRBs.

  14. X-ray reflection and scatter measurements on selected optical samples

    Science.gov (United States)

    Fields, S. A.; Reynolds, J. M.; Holland, R. L.

    1975-01-01

    The results from an experimental program to determine the reflection efficiency and scatter parameters of selected optical samples are presented. The measurements were made using 8.34A X-rays at various angles of incidence. Selected samples were contaminated after being measured and then remeasured to determine the effects of contamination. The instrumentation involved in taking the data, including the X-ray reflectometer and data processing equipment, is discussed in detail. The condition of the optical surfaces, the total reflection measurements, the scatter measurements, and the analysis are discussed.

  15. Observation of charge ordering by X-ray anomalous scattering

    CERN Document Server

    Sasaki, S; Konoike, Y; Yamawaki, K; Tanaka, M

    2001-01-01

    Anomalous scattering technique was applied for the detection of charge ordering of Fe sub 3 O sub 4 and Eu sub 3 S sub 4 at low temperatures. The energy and temperature dependent features were clearly observed for forbidden and superlattice reflections in the systems. The energy-dependence curve for Fe sub 3 O sub 4 gives a minimum intensity at E=7.122 keV, which can be related to the valence contrast by ion pairings. Energy dependence experiments on critical scattering have revealed the existence of valence-ions correlation.

  16. Coherent X-ray scattering beamline at port 9C of Pohang Light Source II.

    Science.gov (United States)

    Yu, Chung-Jong; Lee, Hae Cheol; Kim, Chan; Cha, Wonsuk; Carnis, Jerome; Kim, Yoonhee; Noh, Do Young; Kim, Hyunjung

    2014-01-01

    The coherent X-ray scattering beamline at the 9C port of the upgraded Pohang Light Source (PLS-II) at Pohang Accelerator Laboratory in Korea is introduced. This beamline provides X-rays of 5-20 keV, and targets coherent X-ray experiments such as coherent diffraction imaging and X-ray photon correlation spectroscopy. The main parameters of the beamline are summarized, and some preliminary experimental results are described.

  17. Tomographic imaging of bone composition using coherently scattered x rays

    Science.gov (United States)

    Batchelar, Deidre L.; Dabrowski, W.; Cunningham, Ian A.

    2000-04-01

    Bone tissue consists primarily of calcium hydroxyapatite crystals (bone mineral) and collagen fibrils. Bone mineral density (BMD) is commonly used as an indicator of bone health. Techniques available at present for assessing bone health provide a measure of BMD, but do not provide information about the degree of mineralization of the bone tissue. This may be adequate for assessing diseases in which the collagen-mineral ratio remains constant, as assumed in osteoporosis, but is insufficient when the mineralization state is known to change, as in osteomalacia. No tool exists for the in situ examination of collagen and hydroxyapatite density distributions independently. Coherent-scatter computed tomography (CSCT) is a technique we are developing that produces images of the low- angle scatter properties of tissue. These depend on the molecular structure of the scatterer making it possible to produce material-specific maps of each component in a conglomerate. After corrections to compensate for exposure fluctuations, self-attenuation of scatter and the temporal response of the image intensifier, material-specific images of mineral, collagen, fat and water distributions are obtained. The gray-level in these images provides the volumetric density of each component independently.

  18. Nonlinear coherent Thomson scattering from relativistic electron sheets as a means to produce isolated ultrabright attosecond x-ray pulses

    Directory of Open Access Journals (Sweden)

    H.-C. Wu (武慧春

    2011-07-01

    Full Text Available A new way to generate intense attosecond x-ray pulses is discussed. It relies on coherent Thomson scattering (CTS from relativistic electron sheets. A double layer technique is used to generate planar solid-density sheets of monochromatic high-γ electrons with zero transverse momentum such that coherently backscattered light is frequency upshifted by factors up to 4γ^{2}. Here previous work [H.-C. Wu et al., Phys. Rev. Lett. 104, 234801 (2010PRLTAO0031-900710.1103/PhysRevLett.104.234801] is extended to the regime of high-intensity probe light with normalized amplitude a_{0}>1 leading to nonlinear CTS effects such as pulse contraction and steepening. The results are derived both by particle-in-cell (PIC simulation in a boosted frame and by analytic theory. PIC simulation shows that powerful x-ray pulses (1 keV, 10   gigawatt can be generated. They call for experimental verification. Required prerequisites such as manufacture of nanometer-thick target foils is ready and ultrahigh contrast laser pulses should be within reach in the near future.

  19. Using the X-FEL to understand X-ray Thomson scattering for partially ionized plasmas

    CERN Document Server

    Nilsen, J; Cheng, K T

    2012-01-01

    For the last decade numerous researchers have been trying to develop experimental techniques to use X-ray Thomson scattering as a method to measure the temperature, electron density, and ionization state of high energy density plasmas such as those used in inertial confinement fusion. With the advent of the X-ray free electron laser (X-FEL) at the SLAC Linac Coherent Light Source (LCLS) we now have such a source available in the keV regime. One challenge with X-ray Thomson scattering experiments is understanding how to model the scattering for partially ionized plasmas. Most Thomson scattering codes used to model experimental data greatly simplify or neglect the contributions of the bound electrons to the scattered intensity. In this work we take the existing models of Thomson scattering that include elastic ion-ion scattering and the electron-electron plasmon scattering and add the contribution of the bound electrons in the partially ionized plasmas. Except for hydrogen plasmas almost every plasma that is st...

  20. Building a Unified Computational Model for the Resonant X-Ray Scattering of Strongly Correlated Materials

    Energy Technology Data Exchange (ETDEWEB)

    Bansil, Arun [Northeastern Univ., Boston, MA (United States)

    2016-12-01

    Basic-Energy Sciences of the Department of Energy (BES/DOE) has made large investments in x-ray sources in the U.S. (NSLS-II, LCLS, NGLS, ALS, APS) as powerful enabling tools for opening up unprecedented new opportunities for exploring properties of matter at various length and time scales. The coming online of the pulsed photon source literally allows us to see and follow the dynamics of processes in materials at their natural timescales. There is an urgent need therefore to develop theoretical methodologies and computational models for understanding how x-rays interact with matter and the related spectroscopies of materials. The present project addressed aspects of this grand challenge of X-ray science. In particular, our Collaborative Research Team (CRT) focused on understanding and modeling of elastic and inelastic resonant X-ray scattering processes. We worked to unify the three different computational approaches currently used for modeling X-ray scattering—density functional theory, dynamical mean-field theory, and small-cluster exact diagonalization—to achieve a more realistic material-specific picture of the interaction between X-rays and complex matter. To achieve a convergence in the interpretation and to maximize complementary aspects of different theoretical methods, we concentrated on the cuprates, where most experiments have been performed. Our team included both US and international researchers, and it fostered new collaborations between researchers currently working with different approaches. In addition, we developed close relationships with experimental groups working in the area at various synchrotron facilities in the US. Our CRT thus helped toward enabling the US to assume a leadership role in the theoretical development of the field, and to create a global network and community of scholars dedicated to X-ray scattering research.

  1. Coherent Resonant Soft X-ray Scattering Study of Magnetic Textures in FeGe

    Directory of Open Access Journals (Sweden)

    Victor Ukleev

    2018-01-01

    Full Text Available Coherent resonant soft X-ray scattering was utilized to examine the magnetic textures in a thin plate of the cubic B20 compound FeGe. Small-angle scattering patterns were measured with controlled temperatures and magnetic fields exhibiting magnetic scattering from a helical texture and skyrmion lattice. By measuring the scattering pattern in a saturation magnetic field, magnetic and charge scattering were distinguished and an iterative phase retrieval algorithm was applied to reconstruct the magnetic texture in the real-space. Results of the real-space reconstruction of magnetic texture from two independently measured datasets were used to compare the reliability of the retrieval.

  2. Reconstruction of the X-ray tube spectrum from a scattering measurement

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Jorge E., E-mail: jorge.fernandez@unibo.it [Laboratory of Montecuccolino, Department of Energy, Nuclear and Environmental Control Engineering (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli,16, I-40136, Bologna (Italy); Scot, Viviana [Laboratory of Montecuccolino, Department of Energy, Nuclear and Environmental Control Engineering (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli,16, I-40136, Bologna (Italy); Bare, Jonathan [Laboratory of Montecuccolino, Department of Energy, Nuclear and Environmental Control Engineering (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli,16, I-40136, Bologna (Italy); Laboratory of Nuclear and Radiological Physics, Institut Superieur Industriel de Bruxelles (ISIB) (Belgium); Tondeur, Francois [Laboratory of Nuclear and Radiological Physics, Institut Superieur Industriel de Bruxelles (ISIB) (Belgium); Gallardo, Sergio; Rodenas, Jose [Department of Chemical and Nuclear Engineering, Polytechnic University of Valencia (Spain); Rossi, Pier Luca [Operational Unit of Health Physics, Alma Mater Studiorum University of Bologna (Italy)

    2012-07-15

    An inverse technique has been designed to unfold the x-ray tube spectrum from the measurement of the photons scattered by a target interposed in the path of the beam. A special strategy is necessary to circumvent the ill-conditioning of the forward transport algebraic problem. The proposed method is based on the calculation of both, the forward and adjoint analytical solutions of the Boltzmann transport equation. After testing the method with numerical simulations, a simple prototype built at the Operational Unit of Health Physics of the University of Bologna was used to test the method experimentally. The reconstructed spectrum was validated by comparison with a straightforward measurement of the X-ray beam. The influence of the detector was corrected in both cases using standard unfolding techniques. The method is capable to accurately characterize the intensity distribution of an X-ray tube spectrum, even at low energies where other methods fail. - Highlights: Black-Right-Pointing-Pointer A complete inverse technique of source unfolding is presented. Black-Right-Pointing-Pointer The X-ray tube spectrum is recovered from a scattering measurement. Black-Right-Pointing-Pointer The ill conditioning of the plain forward transport algebraic problem is avoided. Black-Right-Pointing-Pointer Forward and adjoint solutions of the Boltzmann transport equation are used. Black-Right-Pointing-Pointer The technique characterizes X-ray tube spectra even at low energies.

  3. Data Analysis Of Small Angle X-Ray Solution Scattering And Its ...

    African Journals Online (AJOL)

    Small Angle X-ray Scattering analysis was used for the study of the protein, Human Tumour Necrosis Factor (TNF) homogeneously dispersed in solution. The experiment consisted in sending a well collimated beam of synchrotron radiation of wavelength, λ through the sample and measuring the variation of the intensity as a ...

  4. Predictions of x-ray scattering spectra in warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Starrett, Charles E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Saumon, Didier [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Souza, Andre N. [Univ. of Michigan, Ann Arbor, MI (United States); Perkins, David J. [Univ. of California, Los Angeles, CA (United States); Hansen, Stephanie B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-03-12

    This presentation gives an Introduction to our model of warm dense matter; How x-ray scattering spectra are calculated from it; Comparisons with experiments: Room temperature/pressure beryllium Warm dense beryllium Warm dense aluminum; Predictions for warm dense beryllium and titanium; and, Conclusions.

  5. Oil classification using X-ray scattering and principal component analysis

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Danielle S.; Souza, Amanda S.; Lopes, Ricardo T., E-mail: dani.almeida84@gmail.com, E-mail: ricardo@lin.ufrj.br, E-mail: amandass@bioqmed.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Oliveira, Davi F.; Anjos, Marcelino J., E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica Armando Dias Tavares

    2015-07-01

    X-ray scattering techniques have been considered promising for the classification and characterization of many types of samples. This study employed this technique combined with chemical analysis and multivariate analysis to characterize 54 vegetable oil samples (being 25 olive oils)with different properties obtained in commercial establishments in Rio de Janeiro city. The samples were chemically analyzed using the following indexes: iodine, acidity, saponification and peroxide. In order to obtain the X-ray scattering spectrum, an X-ray tube with a silver anode operating at 40kV and 50 μA was used. The results showed that oils cab ne divided in tow large groups: olive oils and non-olive oils. Additionally, in a multivariate analysis (Principal Component Analysis - PCA), two components were obtained and accounted for more than 80% of the variance. One component was associated with chemical parameters and the other with scattering profiles of each sample. Results showed that use of X-ray scattering spectra combined with chemical analysis and PCA can be a fast, cheap and efficient method for vegetable oil characterization. (author)

  6. Small angle X-ray scattering study of calreticulin reveals conformational plasticity

    DEFF Research Database (Denmark)

    Toft, Katrine Nørgaard; Larsen, Nanna; Jørgensen, Flemming Steen

    2008-01-01

    Calreticulin plays a central role in vital cell processes such as protein folding, Ca(2+) homeostasis and immunogenicity. Even so, only limited three-dimensional structural information is presently available. We present a series of Small-Angle X-ray Scattering data on human placenta calreticulin...

  7. Three-dimensional Morphology and X-ray Scattering Structure of ...

    Indian Academy of Sciences (India)

    Abstract. It is well established that water-alcohol mixtures exhibit anomalous properties at very low as well ... of water and tert-butanol (TBA) by using simulated X-ray scattering structure function, S(q), real space radial and spatial ... which is due to polar-polar and nonpolar-polar correlations in pure TBA, seems to appear.

  8. High resolution X-ray scattering studies of substrates and multilayers

    DEFF Research Database (Denmark)

    Christensen, Finn Erland

    1988-01-01

    High resolution X-ray scattering measurements on multilayer substrates and surfaces are reviewed. It is shown that the usual substrates of float glass and Si-wafers are dominated by large scale figure error, whereas samples of super polished SiC substrates are comparable in flatness and roughness...

  9. Diffuse X-ray scattering and far infrared absorption of barium and lead β" aluminas

    DEFF Research Database (Denmark)

    Hayes, W.; Kjær, Kristian; Pratt, F. L.

    1985-01-01

    The authors have carried out high-momentum-resolution studies in diffuse X-ray scattering of barium and lead B" aluminas in the temperature range 20-700 degrees C. They have also measured the vibrational spectra of these compounds between 2K and 300K in the energy range 10-100 cm-1. The results...

  10. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing

    NARCIS (Netherlands)

    Ramamurthy, S.; D'Orsi, C.J.; Sechopoulos, I.

    2016-01-01

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360 degrees with a

  11. X-ray measurements of total reflectivity and scattering from Au-coated foils

    DEFF Research Database (Denmark)

    Hornstrup, Allan; Christensen, Finn Erland; Jespersen, Ellen

    1990-01-01

    We present x-ray measurements of total reflectivity and scattering from gold-coated foils. The foils are two sorts of 0.3 mm thick dip-lacquered aluminum, 0.125 mm thick plastic (Upilex) and 0.5 mm thick dip-lacquered nickel. The analysis of the data shows a high reflectivity for all...

  12. X-Ray Measurements Of Total Reflectivity And Scattering From Au-Coated Foils

    DEFF Research Database (Denmark)

    Hornstrup, Allan; Christensen, Finn Erland; Schnopper, H. W.

    1989-01-01

    We present X-ray measurements of total reflectivity and scattering from gold coated foils. The foils are two sorts of 0.3 mm thick dip-lacquered aluminum, 0.125 mm thick plastic (Upilex) and 0.5 mm thick dip-lacquered nickel. The analysis of the data show a high reflectivity for all but the plastic...

  13. Resonant soft x-ray scattering and charge density waves in correlated systems

    NARCIS (Netherlands)

    Rusydi, Andrivo

    2006-01-01

    Summary This work describes results obtained on the study of charge density waves (CDW) in strongly correlated systems with a new experimental method: resonant soft x-ray scattering (RSXS). The basic motivation is the 1986 discovery by Bednorz and Müler of a new type of superconductor, based on Cu

  14. Ultra Small-angle X-ray Scattering Study of Flocculation in Silica-filled Rubber

    NARCIS (Netherlands)

    Mihara, S.; Datta, Rabin; Dierkes, Wilma K.; Noordermeer, Jacobus W.M.; Amino, N.; Ishikawa, Y.; Nishitsuji, S.; Takenaka, M.

    2014-01-01

    The flocculation of silica during vulcanization is monitored using the ultra small-angle X-ray scattering technique for two different types of silica: a highly dispersible silica (HD) and a conventional silica (CV), mixed into a blend of S-SBR and BR rubbers. The cutoff length of the silica

  15. Antiferromagnetic order in superconducting UPt[sub 3]: An x-ray magnetic scattering study (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Isaacs, E.D. (AT T Bell Laboratories, 600 Mountain Avenue, Murray Hill, New Jersey 07974 (United States)); Zschack, P. (Oak Ridge Institute for Science and Education, Brookhaven National Laboratory, Upton, New York 11973 (United States)); Ramirez, A.P.; Oglesby, C.S.; Bucher, E. (AT T Bell Laboratories, 600 Mountain Avenue, Murray Hill, New Jersey 07974 (United States))

    1994-11-15

    The temperature dependence of the antiferromagnetic order in superconducting UPt[sub 3] has been measured using x-ray resonance magnetic scattering. The magnetic Bragg intensity at [ital Q]=(1/2,0,2) grows linearly from [ital T][sub [ital N

  16. Elementary scattering theory for X-ray and neutron users

    CERN Document Server

    Sivia, D S

    2011-01-01

    The opportunities for doing scattering experiments at synchrotron and neutron facilities have grown rapidly in recent years and are set to continue to do so into the foreseeable future. This text provides a basic understanding of how these techniques enable the structure and dynamics of materials to be studied at the atomic and molecular level. Although mathematics cannot be avoided in a theoretical discussion, the aim has been to write a book that most scientists will still find approachable. To this end, the first two chapters are devoted to providing a tutorial background in the mathematics and physics that are implicitly assumed in other texts. Thereafter, the philosophy has been one of keeping things as simple as possible.

  17. A United Effort for Crystal Growth, Neutron Scattering, and X-ray Scattering Studies of Novel Correlated Electron Materials

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young S. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-02-12

    The research accomplishments during the award involved experimental studies of correlated electron systems and quantum magnetism. The techniques of crystal growth, neutron scattering, x-ray scattering, and thermodynamic & transport measurements were employed, and graduate students and postdoctoral research associates were trained in these techniques.

  18. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams

    CERN Document Server

    Brown, Thomas A D; Alvarez, Diane; Matthews, Kenneth L; Ham, Kyungmin; Dugas, Joseph P; 10.1118/1.4767770

    2012-01-01

    This work investigates the dose-response curves of GAFCHROMIC EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility. Monochromatic beams of 25, 30, and 35 keV were generated on the tomography beamline at CAMD. Ion chamber depth-dose measurements were used to determine the dose delivered to films irradiated at depths from 0.7 to 8.5 cm in a 10x10x10-cm3 PMMA phantom. AAPM TG-61 protocol was applied to convert measured ionization into dose. Films were digitized using an Epson 1680 Professional flatbed scanner and analyzed using the net optical density (NOD) derived from the red channel. A dose-response curve was obtained at 35 keV for EBT film, and at 25, 30, and 35 keV for EBT2 and EBT3 films. Calibrations of films for 4 MV x-rays were obtained for comparison using a radiotherapy accelerator at Mary Bird Perkins Cancer Cent...

  19. Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Faustlin, R R; Toleikis, S; Bornath, T; Doppner, T; Dusterer, S; Forster, E; Fortmann, C; Glenzer, S H; Gode, S; Gregori, G; Irsig, R; Laarmann, T; Lee, H J; Li, B; Meiwes-Broer, K; Mithen, J; Przystawik, A; Redlin, H; Redmer, R; Reinholz, H; Ropke, G; Tavella, F; Thiele, R; Tiggesbaumker, J; Uschmann, I; Zastrau, U; Tschentscher, T

    2009-07-15

    We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

  20. Application of Small-Angle Neutron and X-ray Scattering in Determining Lipid Bilayer Structure

    Science.gov (United States)

    Pan, Jianjun; Heberle, Frederick A.; Kucerka, Norbert; Tristram-Nagle, Stephanie; Szymanski, Michelle; Koepfinger, Mary; Katsaras, John

    2012-02-01

    Accurately determining lipid structure in biologically relevant fluid bilayers is not straightforward. We have recently developed a hybrid experimental/computational technique (i.e., the scattering density profile, or SDP model), which exploits the fact that neutron and X-ray scattering are sensitive to different bilayer thicknesses - the large difference in neutron scattering length density (SLD) between proteated lipid and deuterated water defines the overall bilayer thickness, while X-ray scattering resolves the headgroup-headgroup distance due to the large scattering contrast between the electron-rich phosphate groups and the hydrocarbon/aqueous medium. A key step in the SDP analysis is the use of MD simulations to parse the lipid molecule into fragments whose volume probability distributions follow simple analytical functional forms. Given the appropriate atomic scattering lengths, these volume probabilities can simultaneously predict both the neutron and X-ray SLD profiles, and hence the scattering form factors. Structural results for commonly used phosphatidylcholine and phosphatidylglycerol lipids will be given.

  1. Fast scattering simulation tool for multi-energy x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sossin, A., E-mail: artur.sossin@cea.fr [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Tabary, J.; Rebuffel, V. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Létang, J.M.; Freud, N. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Claude Bernard Lyon 1, Centre Léon Bérard (France); Verger, L. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France)

    2015-12-01

    A combination of Monte Carlo (MC) and deterministic approaches was employed as a means of creating a simulation tool capable of providing energy resolved x-ray primary and scatter images within a reasonable time interval. Libraries of Sindbad, a previously developed x-ray simulation software, were used in the development. The scatter simulation capabilities of the tool were validated through simulation with the aid of GATE and through experimentation by using a spectrometric CdTe detector. A simple cylindrical phantom with cavities and an aluminum insert was used. Cross-validation with GATE showed good agreement with a global spatial error of 1.5% and a maximum scatter spectrum error of around 6%. Experimental validation also supported the accuracy of the simulations obtained from the developed software with a global spatial error of 1.8% and a maximum error of around 8.5% in the scatter spectra.

  2. Nonlinear resonance scattering of femtosecond X-ray pulses on atoms in plasmas

    Science.gov (United States)

    Rosmej, F. B.; Astapenko, V. A.; Lisitsa, V. S.; Moroz, N. N.

    2017-11-01

    It is shown that for sufficiently short pulses the resonance scattering probability becomes a nonlinear function of the pulse duration. For fs X-ray pulses scattered on atoms in plasmas maxima and minima develop in the nonlinear regime whereas in the limit of long pulses the probability becomes linear and turns over into the standard description of the electromagnetic pulse scattering. Numerical calculations are carried out in terms of a generalized scattering probability for the total time of pulse duration including fine structure splitting and ion Doppler broadening in hot plasmas. For projected X-ray monocycles, the generalized nonlinear approach differs by 1-2 orders of magnitude from the standard theory.

  3. Low-angle polarized neutron and X-ray scattering from magnetic nanolayers and nanostructures

    CERN Document Server

    Paul, Amitesh

    2017-01-01

    This research monograph presents the latest results related to the characterization of low dimensional systems. Low-angle polarized neutron scattering and X-ray scattering at grazing incidence are used as the two main techniques to explore various physical phenomena of these systems. Special focus is put on systems like thin film transition metal and rare-earth layers, oxide heterostructures, hybrid systems, self-assembled nanostructures and self-diffusion.  Readers will gain in-depth knowledge about the usage of specular scattering and off-specular scattering techniques. Investigation of in-plane and out-of-plane structures and magnetism with vector magnetometric information is illustrated comprehensively. The book caters to a wide audience working in the field of nano-dimensional magnetic systems and the neutron and X-ray reflectometry community in particular.

  4. Anomalous scattering, transport, and spatial distribution of X-ray fluorescence at the exit of polycapillary structures

    Energy Technology Data Exchange (ETDEWEB)

    Mazuritskiy, M. I., E-mail: mazurmik@gmail.com; Lerer, A. M.; Makhno, P. V. [Southern Federal University (Russian Federation)

    2016-12-15

    The angular distribution of the X-ray intensity at the exit of microchannel plates at grazing incidence of monochromatic radiation on the walls of microcapillaries has been investigated. The angles and energies of the primary radiation quanta at which the synchrotron beam excites X-ray fluorescence propagating inside polycapillary structures have been determined. The angular dependences of the intensity distribution of X-rays transmitted through the microcapillaries have been studied theoretically and experimentally for energies corresponding to the region of anomalous dispersion near the L{sub 2,3} absorption edges of silicon. The propagation of waves in hollow polycapillary waveguides, the excitation of X-ray fluorescence, and the X-ray diffraction at the exit of microchannel plates have been modeled mathematically. The mathematical model takes into account the presence of a transition layer on the microchannel surface.

  5. Solving atomic structures using statistical mechanical searches on x-ray scattering derived potential energy surfaces

    Science.gov (United States)

    Wright, Christopher James

    Engineering the next generation of materials, especially nanomaterials, requires a detailed understanding of the material's underlying atomic structure. These structures give us better insight into structure-property relationships, allowing for property driven material design on the atomic level. Even more importantly, understanding structures in-situ will translate stimuli and responses on the macroscopic scale to changes on the nanoscale. Despite the importance of precise atomic structures for materials design, solving atomic structures is difficult both experimentally and computationally. Atomic pair distribution functions (PDFs) provide information on atomic structure, but the difficulty of extracting the PDF from x-ray total scattering measurements limits their use. Translating the PDF into an atomic structure requires the search of a very high dimensional space, the set of all potential atomic configurations. The large computational cost of running these simulations also limits the use of PDF as an atomistic probe. This work aims to address these issues by developing 1) novel statistical mechanical approaches to solving material structures, 2) fast simulation of x-ray total scattering and atomic pair distribution functions (PDFs), and 3) data processing procedures for experimental x-ray total scattering measurements. First, experimentally derived potential energy surfaces (PES) and the statistical mechanical ensembles used to search them are developed. Then the mathematical and computational framework for the PDF and its gradients will be discussed. The combined PDF-PES-ensemble system will be benchmarked against a series of nanoparticle structures to ascertain the efficiency and effectiveness of the system. Experimental data processing procedures, which maximize the usable data, will be presented. Finally, preliminary results from experimental x-ray total scattering measurements will be discussed. This work presents one of the most complete end

  6. Measurement and Interpretation of Diffuse Scattering in X-Ray Diffraction for Macromolecular Crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Wall, Michael E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-16

    X-ray diffraction from macromolecular crystals includes both sharply peaked Bragg reflections and diffuse intensity between the peaks. The information in Bragg scattering reflects the mean electron density in the unit cells of the crystal. The diffuse scattering arises from correlations in the variations of electron density that may occur from one unit cell to another, and therefore contains information about collective motions in proteins.

  7. Blackening of unprotected dental X-ray films due to scattered radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sewerin, I.; Stoltze, K.

    1988-01-01

    Unexposed films awaiting exposure as well as exposed films awaiting processing are subjected to scattered radiation if kept unprotected in the dental X-ray clinic. The purpose of the present study was to analyze the influence of various storing principles, film speed, and distance from X-ray source upon the degree of film blackening. Test films were subjected to scattered radiation from 150 exposures. Maximum additional blackening (0.27 D) was recorded for type E films not protected by lead foil at the shortest distance studied (55 cm). At a distance of 200 cm blackening was reduced to 0.02 D and could be further reduced by utilizing the inherent protective effect of the lead foil. It is concluded that if dental X-ray films not in use are kept a distance of 200 cm from the X-ray source and protected by lead foil additional blackening due to scattered radiation is negligible and further protective precautions are unnecessary.

  8. Microbubbles as x-ray scattering contrast agents using analyzer-based imaging

    Energy Technology Data Exchange (ETDEWEB)

    Arfelli, F [Department of Physics, University of Trieste, Via Valerio 2, 34127 Trieste (Italy); Rigon, L [Istituto Nazionale di Fisica Nucleare-Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Menk, R H [Sincrotrone Trieste S.C.p.A., Strada Statale 14-km 163.5 in AREA Science Park, 34012 Basovizza, Trieste (Italy)

    2010-03-21

    Conventional contrast agents utilized in diagnostic radiology are based on x-ray absorption properties; alternative physical principles capable of providing a contrast enhancement in radiographs have never been applied. This study exploits the possibility of using a novel type of contrast media based on x-ray scattering. The contrast agents consist of microbubble echo-enhancing agents, usually applied in ultrasound examinations, which are invisible with conventional x-ray absorption techniques. The experiment was carried out at the medical beamline of the synchrotron radiation laboratory ELETTRA in Trieste, Italy. A flat silicon analyzer crystal typically used for diffraction-enhanced imaging was utilized as a tool for detecting the scattering properties of the contrast agents. In analyzer-based imaging, it is possible to detect the scattering properties of the sample by shifting the analyzer crystal to selected positions of its reflectivity curve. In particular, when the sample consists of a large number of micro-particles an overall effect can be observed. Phantoms containing contrast agents based on microbubbles were imaged at different angular positions of the analyzer crystal. High visibility of the details was demonstrated, and a strong contrast enhancement was measured compared to normal x-ray absorption techniques.

  9. Inelastic X-ray scattering experiments at extreme conditions: high temperatures and high pressures

    Directory of Open Access Journals (Sweden)

    S.Hosokawa

    2008-03-01

    Full Text Available In this article, we review the present status of experimental techniques under extreme conditions of high temperature and high pressure used for inelastic X-ray scattering (IXS experiments of liquid metals, semiconductors, molten salts, molecular liquids, and supercritical water and methanol. For high temperature experiments, some types of single-crystal sapphire cells were designed depending on the temperature of interest and the sample thickness for the X-ray transmission. Single-crystal diamond X-ray windows attached to the externally heated high-pressure vessel were used for the IXS experiment of supercritical water and methanol. Some typical experimental results are also given, and the perspective of IXS technique under extreme conditions is discussed.

  10. Imaging of Biological Materials and Cells by X-ray Scattering and Diffraction.

    Science.gov (United States)

    Hémonnot, Clément Y J; Köster, Sarah

    2017-09-26

    Cells and biological materials are large objects in comparison to the size of internal components such as organelles and proteins. An understanding of the functions of these nanoscale elements is key to elucidating cellular function. In this review, we describe the advances in X-ray scattering and diffraction techniques for imaging biological systems at the nanoscale. We present a number of principal technological advances in X-ray optics and development of sample environments. We identify radiation damage as one of the most severe challenges in the field, thus rendering the dose an important parameter when putting different X-ray methods in perspective. Furthermore, we describe different successful approaches, including scanning and full-field techniques, along with prominent examples. Finally, we present a few recent studies that combined several techniques in one experiment in order to collect highly complementary data for a multidimensional sample characterization.

  11. Model-independent particle species disentanglement by X-ray cross-correlation scattering

    Science.gov (United States)

    Pedrini, B.; Menzel, A.; Guzenko, V. A.; David, C.; Abela, R.; Gutt, C.

    2017-04-01

    Mixtures of different particle species are often investigated using the angular averages of the scattered X-ray intensity. The number of species is deduced by singular value decomposition methods. The full disentanglement of the data into per-species contributions requires additional knowledge about the system under investigation. We propose to exploit higher-order angular X-ray intensity correlations with a new computational protocol, which we apply to synchrotron data from two-species mixtures of two-dimensional static test nanoparticles. Without any other information besides the correlations, we demonstrate the assessment of particle species concentrations in the measured data sets, as well as the full ab initio reconstruction of both particle structures. The concept extends straightforwardly to more species and to the three-dimensional case, whereby the practical application will require the measurements to be performed at an X-ray free electron laser.

  12. Extending resonant inelastic X-ray scattering to the extreme ultraviolet

    Directory of Open Access Journals (Sweden)

    L. Andrew eWray

    2015-05-01

    Full Text Available In resonant inelastic X-ray scattering (RIXS, core hole resonance modes are used to enhance coupling between photons and low energy electronic degrees of freedom. Resonating with shallow core holes accessed in the extreme ultraviolet (EUV can provide greatly improved energy resolution at standard resolving power, but has been found to often yield qualitatively different spectra than similar measurements performed with higher energy X-rays. This paper uses experimental data and multiplet-based numerical simulations for the M-edges of Co-, Ni- and Cu-based Mott insulators to review the properties that distinguish EUV RIXS from more commonly performed higher energy measurements. Key factors such as the origin of the strong EUV elastic line and advantages of EUV spectral functions over soft X-ray RIXS for identifying intrinsic excitation line shapes are discussed.

  13. Predicting X-ray diffuse scattering from translation–libration–screw structural ensembles

    Energy Technology Data Exchange (ETDEWEB)

    Van Benschoten, Andrew H. [University of California San Francisco, San Francisco, CA 94158 (United States); Afonine, Pavel V. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Terwilliger, Thomas C.; Wall, Michael E. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Jackson, Colin J. [Australian National University, Canberra, ACT 2601 (Australia); Sauter, Nicholas K. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Adams, Paul D. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); University of California Berkeley, Berkeley, CA 94720 (United States); Urzhumtsev, Alexandre [Institut de Génétique et de Biologie Moléculaire et Cellulaire, CNRS–INSERM–UdS, 1 Rue Laurent Fries, BP 10142, 67404 Illkirch (France); Université de Lorraine, BP 239, 54506 Vandoeuvre-les-Nancy (France); Fraser, James S., E-mail: james.fraser@ucsf.edu [University of California San Francisco, San Francisco, CA 94158 (United States)

    2015-07-28

    A method of simulating X-ray diffuse scattering from multi-model PDB files is presented. Despite similar agreement with Bragg data, different translation–libration–screw refinement strategies produce unique diffuse intensity patterns. Identifying the intramolecular motions of proteins and nucleic acids is a major challenge in macromolecular X-ray crystallography. Because Bragg diffraction describes the average positional distribution of crystalline atoms with imperfect precision, the resulting electron density can be compatible with multiple models of motion. Diffuse X-ray scattering can reduce this degeneracy by reporting on correlated atomic displacements. Although recent technological advances are increasing the potential to accurately measure diffuse scattering, computational modeling and validation tools are still needed to quantify the agreement between experimental data and different parameterizations of crystalline disorder. A new tool, phenix.diffuse, addresses this need by employing Guinier’s equation to calculate diffuse scattering from Protein Data Bank (PDB)-formatted structural ensembles. As an example case, phenix.diffuse is applied to translation–libration–screw (TLS) refinement, which models rigid-body displacement for segments of the macromolecule. To enable the calculation of diffuse scattering from TLS-refined structures, phenix.tls-as-xyz builds multi-model PDB files that sample the underlying T, L and S tensors. In the glycerophosphodiesterase GpdQ, alternative TLS-group partitioning and different motional correlations between groups yield markedly dissimilar diffuse scattering maps with distinct implications for molecular mechanism and allostery. These methods demonstrate how, in principle, X-ray diffuse scattering could extend macromolecular structural refinement, validation and analysis.

  14. Soft x-ray scattering using FEL radiation for probing near-solid density plasmas at few electronvolt temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Toleikis, S; Faustlin, R R; Cao, L; Doppner, T; Dusterer, S; Forster, E; Fortmann, C; Glenzer, S H; Gode, S; Gregori, G; Irsig, R; Laarmann, T; Lee, H J; Li, B; Meiwes-Broer, K; Przystawik, A; Radcliffe, P; Redmer, R; Tavella, F; Thiele, R; Tiggesbaumker, J; Truong, N X; Uschmann, I; Zastrau, U; Tschentscher, T

    2009-03-03

    We report on soft x-ray scattering experiments on cryogenic hydrogen and simple metal targets. As a source of intense and ultrashort soft x-ray pulses we have used free-electron laser radiation at 92 eV photon energy from FLASH at DESY, Hamburg. X-ray pulses with energies up to 100 {micro}J and durations below 50 fs provide interaction with the target leading simultaneously to plasma formation and scattering. Experiments exploiting both of these interactions have been carried out, using the same experimental setup. Firstly, recording of soft x-ray inelastic scattering from near-solid density hydrogen plasmas at few electronvolt temperatures confirms the feasibility of this diagnostics technique. Secondly, the soft x-ray excitation of few electronvolt solid-density plasmas in simple metals could be studied by recording soft x-ray line and continuum emission integrated over emission times from fs to ns.

  15. Design of a 4.8-m ring for inverse Compton scattering x-ray source

    Directory of Open Access Journals (Sweden)

    H. S. Xu

    2014-07-01

    Full Text Available In this paper we present the design of a 50 MeV compact electron storage ring with 4.8-meter circumference for the Tsinghua Thomson scattering x-ray source. The ring consists of four dipole magnets with properly adjusted bending radii and edge angles for both horizontal and vertical focusing, and a pair of quadrupole magnets used to adjust the horizontal damping partition number. We find that the dynamic aperture of compact storage rings depends essentially on the intrinsic nonlinearity of the dipole magnets with small bending radius. Hamiltonian dynamics is found to agree well with results from numerical particle tracking. We develop a self-consistent method to estimate the equilibrium beam parameters in the presence of the intrabeam scattering, synchrotron radiation damping, quantum excitation, and residual gas scattering. We also optimize the rf parameters for achieving a maximum x-ray flux.

  16. Double-confocal resonator for X-ray generation via intracavity Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Xie, M. [Lawrence Berkeley Lab., CA (United States)

    1995-12-31

    There has been a growing interest in developing compact X-ray sources through Thomson scattering of a laser beam by a relativistic electron beam. For higher X-ray flux it is desirable to have the scattering to occur inside an optical resonator where the laser power is higher. In this paper I propose a double-confocal resonator design optimized for head-on Thomson scattering inside an FEL oscillator and analyze its performance taking into account the diffraction and FEL gain. A double confocal resonator is equivalent to two confocal resonators in series. Such a resonator has several advantages: it couples electron beam through and X-ray out of the cavity with holes on cavity mirrors, thus allowing the system to be compact; it supports the FEL mode with minimal diffraction loss through the holes; it provides a laser focus in the forward direction for a better mode overlap with the electron beam; and it provides a focus at the same location in the backward direction for higher Thomson scattering efficiency; in addition, the mode size at the focal point and hence the Rayleigh range can be adjusted simply through intracavity apertures; furthermore, it gives a large mode size at the mirrors to reduce power loading. Simulations as well as analytical results will be presented. Also other configurations of intracavity Thomson scattering where the double-confocal resonator could be useful will be discussed.

  17. The life science x-ray scattering beamline at NSLS-II

    Energy Technology Data Exchange (ETDEWEB)

    DiFabio, Jonathan; Chodankar, Shirish; Pjerov, Sal; Jakoncic, Jean; Lucas, Michael; Graziano, Vito; Yang, Lin, E-mail: lyang@bnl.gov [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York (United States); Krywka, Christina [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York (United States); On leave from Institut für Werkstoffforschung, Helmholtz-Zentrum Geesthacht, Hamburg (Germany)

    2016-07-27

    We report the current development status of the High Brightness X-ray Scattering for Life Sciences (or Life Science X-ray Scattering, LiX) beamline at the NSLS-II facility of Brookhaven National Laboratory. This instrument will operate in the x-ray energy range of 2.1-18 keV, provide variable beam sizes from 1 micron to ∼0.5 mm, and support user experiments in three scientific areas: (1) high-throughput solution scattering, in-line size exclusion chromatography and flow mixers-based time-resolved solution scattering of biological macro-molecules, (2) diffraction from single- and multi-layered lipid membranes, and (3) scattering-based scanning probe imaging of biological tissues. In order to satisfy the beam stability required for these experiments and to switch rapidly between different types of experiments, we have adopted a secondary source with refractive lenses for secondary focusing, a detector system consisting of three Pilatus detectors, and specialized experimental modules that can be quickly exchanged and each dedicated to a defined set of experiments. The construction of this beamline is on schedule for completion in September 2015. User experiments are expected to start in Spring 2016.

  18. Large-scale Nanostructure Simulations from X-ray Scattering Data On Graphics Processor Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Sarje, Abhinav; Pien, Jack; Li, Xiaoye; Chan, Elaine; Chourou, Slim; Hexemer, Alexander; Scholz, Arthur; Kramer, Edward

    2012-01-15

    X-ray scattering is a valuable tool for measuring the structural properties of materialsused in the design and fabrication of energy-relevant nanodevices (e.g., photovoltaic, energy storage, battery, fuel, and carbon capture andsequestration devices) that are key to the reduction of carbon emissions. Although today's ultra-fast X-ray scattering detectors can provide tremendousinformation on the structural properties of materials, a primary challenge remains in the analyses of the resulting data. We are developing novelhigh-performance computing algorithms, codes, and software tools for the analyses of X-ray scattering data. In this paper we describe two such HPCalgorithm advances. Firstly, we have implemented a flexible and highly efficient Grazing Incidence Small Angle Scattering (GISAXS) simulation code based on theDistorted Wave Born Approximation (DWBA) theory with C++/CUDA/MPI on a cluster of GPUs. Our code can compute the scattered light intensity from any givensample in all directions of space; thus allowing full construction of the GISAXS pattern. Preliminary tests on a single GPU show speedups over 125x compared tothe sequential code, and almost linear speedup when executing across a GPU cluster with 42 nodes, resulting in an additional 40x speedup compared to usingone GPU node. Secondly, for the structural fitting problems in inverse modeling, we have implemented a Reverse Monte Carlo simulation algorithm with C++/CUDAusing one GPU. Since there are large numbers of parameters for fitting in the in X-ray scattering simulation model, the earlier single CPU code required weeks ofruntime. Deploying the AccelerEyes Jacket/Matlab wrapper to use GPU gave around 100x speedup over the pure CPU code. Our further C++/CUDA optimization deliveredan additional 9x speedup.

  19. Characterizing the behavior of scattered radiation in multi-energy x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sossin, Artur, E-mail: artur.sossin@gmail.com [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Rebuffel, V.; Tabary, J. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Létang, J.M.; Freud, N. [Univ Lyon, INSA-Lyon, Université Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Centre Léon Bérard, CREATIS UMR 5220 U1206, F-69373 Lyon (France); Verger, L. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France)

    2017-04-01

    Scattered radiation results in various undesirable effects in medical diagnostics, non-destructive testing (NDT) and security x-ray imaging. Despite numerous studies characterizing this phenomenon and its effects, the knowledge of its behavior in the energy domain remains limited. The present study aims at summarizing some key insights on scattered radiation originating from the inspected object. In addition, various simulations and experiments with limited collimation on both simplified and realistic phantoms were conducted in order to study scatter behavior in multi-energy x-ray imaging. Results showed that the spectrum shape of the scatter component can be considered preserved in the first approximation across the image plane for various acquisition geometries and phantoms. The variations exhibited by the scatter spectrum were below 10% for most examined cases. Furthermore, the corresponding spectrum shape proved to be also relatively invariant for different experimental angular projections of one of the examined phantoms. The observed property of scattered radiation can potentially lead to the decoupling of spatial and energy scatter components, which can in turn enable speed ups in scatter simulations and reduce the complexity of scatter correction.

  20. Anisotropic x-ray scattering and orientation fields in cardiac tissue cells

    Science.gov (United States)

    Bernhardt, M.; Nicolas, J.-D.; Eckermann, M.; Eltzner, B.; Rehfeldt, F.; Salditt, T.

    2017-01-01

    X-ray diffraction from biomolecular assemblies is a powerful technique which can provide structural information about complex architectures such as the locomotor systems underlying muscle contraction. However, in its conventional form, macromolecular diffraction averages over large ensembles. Progress in x-ray optics has now enabled to probe structures on sub-cellular scales, with the beam confined to a distinct organelle. Here, we use scanning small angle x-ray scattering (scanning SAXS) to probe the diffraction from cytoskeleton networks in cardiac tissue cells. In particular, we focus on actin-myosin composites, which we identify as the dominating contribution to the anisotropic diffraction patterns, by correlation with optical fluorescence microscopy. To this end, we use a principal component analysis approach to quantify direction, degree of orientation, nematic order, and the second moment of the scattering distribution in each scan point. We compare the fiber orientation from micrographs of fluorescently labeled actin fibers to the structure orientation of the x-ray dataset and thus correlate signals of two different measurements: the native electron density distribution of the local probing area versus specifically labeled constituents of the sample. Further, we develop a robust and automated fitting approach based on a power law expansion, in order to describe the local structure factor in each scan point over a broad range of the momentum transfer {q}{{r}}. Finally, we demonstrate how the methodology shown for freeze dried cells in the first part of the paper can be translated to alive cell recordings.

  1. Three-dimensional coherent X-ray surface scattering imaging near total external reflection

    Science.gov (United States)

    Sun, Tao; Jiang, Zhang; Strzalka, Joseph; Ocola, Leonidas; Wang, Jin

    2012-09-01

    Lensless X-ray coherent diffraction imaging (CDI) has emerged as a thriving field promising applications in materials and biological sciences with a theoretical imaging resolution only limited by the X-ray wavelength. Most CDI methods use transmission geometry, which is not suitable for nanostructures grown on opaque substrates or for objects of interest comprising only surfaces or interfaces. Attempts have been made to perform CDI experiments in reflection geometry, both optically and with X-rays, but the reconstruction resulted in mostly planar images, with less success in the third dimension. Here, we discuss the development of coherent surface scattering imaging in grazing-incidence geometry that takes advantage of enhanced X-ray surface scattering and interference near total external reflection. We demonstrate the successful reconstruction of substrate-supported non-periodic surface patterns in three dimensions with nanometre resolution in the direction normal to the substrate, promising wide applications in elucidating structures in substrate-supported and buried nanoelectronics and photonics.

  2. Tissue Equivalent Phantom Design for Characterization of a Coherent Scatter X-ray Imaging System

    Science.gov (United States)

    Albanese, Kathryn Elizabeth

    Scatter in medical imaging is typically cast off as image-related noise that detracts from meaningful diagnosis. It is therefore typically rejected or removed from medical images. However, it has been found that every material, including cancerous tissue, has a unique X-ray coherent scatter signature that can be used to identify the material or tissue. Such scatter-based tissue-identification provides the advantage of locating and identifying particular materials over conventional anatomical imaging through X-ray radiography. A coded aperture X-ray coherent scatter spectral imaging system has been developed in our group to classify different tissue types based on their unique scatter signatures. Previous experiments using our prototype have demonstrated that the depth-resolved coherent scatter spectral imaging system (CACSSI) can discriminate healthy and cancerous tissue present in the path of a non-destructive x-ray beam. A key to the successful optimization of CACSSI as a clinical imaging method is to obtain anatomically accurate phantoms of the human body. This thesis describes the development and fabrication of 3D printed anatomical scatter phantoms of the breast and lung. The purpose of this work is to accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Tissue-equivalent anatomical phantoms were designed to assess the capability of the CACSSI system to classify different types of breast tissue (adipose, fibroglandular, malignant). These phantoms were 3D printed based on DICOM data obtained from CT scans of prone breasts. The phantoms were tested through comparison of measured scatter signatures with those of adipose and fibroglandular tissue from literature. Tumors in the phantom were modeled using a variety of biological tissue including actual surgically excised benign and malignant tissue specimens. Lung based phantoms have also been printed for future

  3. Preliminary small-angle X-ray scattering and X-ray diffraction studies of the BTB domain of lola protein from Drosophila melanogaster

    Science.gov (United States)

    Boyko, K. M.; Nikolaeva, A. Yu.; Kachalova, G. S.; Bonchuk, A. N.; Dorovatovskii, P. V.; Popov, V. O.

    2017-11-01

    The Drosophila genome has several dozens of transcription factors (TTK group) containing BTB domains assembled into octamers. The LOLA protein belongs to this family. The purification, crystallization, and preliminary X-ray diffraction and small-angle X-ray scattering (SAXS) studies of the BTB domain of this protein are reported. The crystallization conditions were found by the vapor-diffusion technique. A very low diffraction resolution (8.7 Å resolution) of the crystals was insufficient for the determination of the threedimensional structure of the BTB domain. The SAXS study demonstrated that the BTB domain of the LOLA protein exists as an octamer in solution.

  4. The GALAXIES beamline at the SOLEIL synchrotron: inelastic X-ray scattering and photoelectron spectroscopy in the hard X-ray range.

    Science.gov (United States)

    Rueff, J P; Ablett, J M; Céolin, D; Prieur, D; Moreno, Th; Balédent, V; Lassalle-Kaiser, B; Rault, J E; Simon, M; Shukla, A

    2015-01-01

    The GALAXIES beamline at the SOLEIL synchrotron is dedicated to inelastic X-ray scattering (IXS) and photoelectron spectroscopy (HAXPES) in the 2.3-12 keV hard X-ray range. These two techniques offer powerful complementary methods of characterization of materials with bulk sensitivity, chemical and orbital selectivity, resonant enhancement and high resolving power. After a description of the beamline components and endstations, the beamline capabilities are demonstrated through a selection of recent works both in the solid and gas phases and using either IXS or HAXPES approaches. Prospects for studies on liquids are discussed.

  5. X-ray scattering study of the interplay between magnetism and structure in CeSb

    CERN Document Server

    McMorrow, D F; Lebech, B; Soerensen, S A; Christensen, M J; Vogt, O

    1997-01-01

    The chemical and magnetic structures of CeSb have been investigated using high-resolution x-ray scattering techniques. Experiments performed in the non-resonant regime (x-ray energy of E = 9.4 keV) showed that when the sample was cooled below its Neel temperature of T sub N approx. 16.5 K, peaks appeared with commensurate wave vectors q. From their polarization and wave-vector dependence, the peaks are deduced to arise mainly from a periodic lattice distortion. In the resonant regime, when the x-ray energy was tuned to the L absorption edges of Ce, weak, resonantly enhanced magnetic scattering was observed at the L sub t sub t edge (E = 6.164 keV), with no scattering found at either L sub t or L sub t sub t sub t. Of the six possible zero-field commensurate magnetic structures reported in earlier neutron experiments, we found the phases with q sub m =2/3 and 4/7 only, with the domain that has moments perpendicular to the surface absent. Neutron scattering experiments on the same single crystal confirm that th...

  6. X-ray resonant scattering study of the quadrupolar order in UPd3

    DEFF Research Database (Denmark)

    McMorrow, D.F.; McEwen, K.A.; Steigenberger, U.

    2001-01-01

    Quadrupolar ordering in a 5f electron system has been observed directly for the first time, using x-ray scattering techniques. In UPd(3) at low temperatures satellite peaks appear at (1, 0, l) (orthorhombic notation) with I odd and even. Both sets of peaks show a resonant enhancement...... of the scattering at the M(IV) edge of U. At resonance, the dominant scattering of the 1 odd peaks occurs in the unrotated polarization channel, whereas for I even a significant rotated component is found. These results are discussed in terms of possible structures of the antiferroquadrupolar phases....

  7. Manifestations of Nonlocal Exchange, Correlation, and Dynamic Effects in X-Ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Jung, M.; Dunford, R.W.; Gemmell, D.S.; Kanter, E.P.; Kraessig, B.; LeBrun, T.W.; Southworth, S.H.; Young, L. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Carney, J.P.; LaJohn, L.; Pratt, R.H. [Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, Pennsylvania 15260 (United States); Bergstrom, P.M. Jr. [N Division, Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    1998-08-01

    We report precise measurements of differential x-ray scattering cross sections in Ne and He from 11{endash}22thinspthinspkeV and develop a method for obtaining predictions of comparable accuracy (1{percent} ). The measurement of ratios (total scattering in Ne to He and Compton to Rayleigh scattering in Ne) facilitates comparison to theories. We find evidence for the need to include nonlocal exchange, electron correlation, and dynamic effects for an accurate description at low Z and conclude that no single current theory is sufficient. {copyright} {ital 1998} {ital The American Physical Society }

  8. Compton scattering x-ray sources driven by laser wakefield acceleration

    Directory of Open Access Journals (Sweden)

    F. V. Hartemann

    2007-01-01

    Full Text Available Recent laser wakefield acceleration experiments have demonstrated the generation of femtosecond, nano-Coulomb, low emittance, nearly monokinetic relativistic electron bunches of sufficient quality to produce bright, tunable, ultrafast x-rays via Compton scattering. Design parameters for a proof-of-concept experiment are presented using a three-dimensional Compton scattering code and a laser-plasma interaction particle-in-cell code modeling the wakefield acceleration process; x-ray fluxes exceeding 10^{21}   s^{-1} are predicted, with a peak brightness >10^{19}   photons/(mm^{2} mrad^{2} s   0.1%   bandwidth.

  9. X-ray scattering on liquid-gas interfaces; Roentgenstreuung an Fluessigkeits-Gas Grenzflaechen

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael

    2006-07-01

    In the framework of this thesis two different theme-fields were studied with dhe methods of the elastic, surface sensitive X-ray scattering. In the first part of the thesis the liquid-gas interfaces water-propane and glycerol-isobutane were studied concerning the structure formation on these interfaces. The system water-propane served for the study of the gas hydrate formation on the water-gas interface. Studies on this interface could give no hints on the formation of propane hydrates or propane-hydrate fragments. However the adsorption of molecularly thin propane films on the water surface was observed. The adsorption behaviour of gases on liquid surfaces was studied by further experiments on the glycerol-isobutane interface. In the second part of the thesis the surfaces of aqueous salt solutions and water were studied. The lateralstructure of these liquid-gas interfaces was studied by the method of the diffuse X-ray scattering.

  10. High-Resolution X-Ray Scattering Topography Using Synchrotron Radiation Microbeam

    Science.gov (United States)

    Chikaura, Yoshinori; Suzuki, Yoshifumi; Kii, Hideki

    1994-02-01

    Although spatial resolution is the most essential factor determining the function of X-ray topography, it has not been improved in 30 years in spite of increasing requirements for highly-resolvable topography in materials science. X-ray scattering topography using a microbeam is a method capable of overcoming this resolution problem. Because the maximum resolution of an apparatus using a sealed-off tube is limited to 20 µ m, we designed and constructed scattering topography equipment using a synchrotron radiation microbeam. In the experiment, the slit system forms the microbeam 7 µ m in diameter. We observed a cellulose distribution in bamboo as a testing material. When the scanning step was 2 µ m, we attained spatial resolution less than 5 µ m.

  11. High-resolution x-ray scatter and reflectivity study of sputtered IR surfaces

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Abdali, S.; Hornstrup, Allan

    1993-01-01

    In recent years there has been an increased interest in the possible use of Ir as the reflecting surface in X-ray telescope programs. An X-ray study of such surfaces produced by sputtering of Ir on highly polished Zerodur flats is presented here. The study was performed using Fe K(alpha) 1 (6.......404 Kev) and Cu K(alpha) 1 (8.048 keV) and includes measurement of total external reflection and scattering. The scattering measurement was made with three different instruments arrangements; one employed a 1D position sensitive detector for low resolution studies giving approximately 30 arcsec resolution...... (FWHM), and the other two arrangements employed channel cut crystals providing resolutions (FWHM) of 5 arcsec and 1 arcsec, respectively at Cu K(alpha) 1. The reflectivity study revealed a very close correspondence with a theoretical model based on recently published optical constants. This important...

  12. Revisiting Bragg's X-ray microscope: scatter based optical transient grating detection of pulsed ionising radiation.

    Science.gov (United States)

    Fullagar, Wilfred K; Paganin, David M; Hall, Chris J

    2011-06-01

    Transient optical gratings for detecting ultrafast signals are routine for temporally resolved photochemical investigations. Many processes can contribute to the formation of such gratings; we indicate use of optically scattering centres that can be formed with highly variable latencies in different materials and devices using ionising radiation. Coherent light scattered by these centres can form the short-wavelength-to-optical-wavelength, incoherent-to-coherent basis of a Bragg X-ray microscope, with inherent scope for optical phasing. Depending on the dynamics of the medium chosen, the way is open to both ultrafast pulsed and integrating measurements. For experiments employing brief pulses, we discuss high-dynamic-range short-wavelength diffraction measurements with real-time optical reconstructions. Applications to optical real-time X-ray phase-retrieval are considered. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Note: Grazing incidence small and wide angle x-ray scattering combined with imaging ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Koerstgens, V.; Meier, R.; Ruderer, M. A.; Guo, S.; Chiang, H.-Y.; Mueller-Buschbaum, P. [Technische Universitaet Muenchen, Physik-Department, Lehrstuhl fuer Funktionelle Materialien, James-Franck-Str. 1, 85748 Garching (Germany); Perlich, J.; Roth, S. V.; Gehrke, R. [HASYLAB, DESY, Notkestr. 85, 22607, Hamburg (Germany)

    2012-07-15

    The combination of grazing incidence small angle x-ray scattering (GISAXS) and grazing incidence wide angle x-ray scattering (GIWAXS) with optical imaging ellipsometry is presented as an upgrade of the available measurement techniques at the wiggler beamline BW4 of the Hamburger Synchrotronstrahlungslabor. The instrument is introduced with the description of the alignment procedure to assure the measurement of imaging ellipsometry and GISAXS/GIWAXS on the same sample spot. To demonstrate the possibilities of the new instrument examples of morphological investigation on films made of poly(3-hexylthiophene) and [6,6]-phenyl-C{sub 61} butyric acid methyl ester as well as textured poly(9,9-dioctylfluorene-alt-benzo-thia-diazole) are shown.

  14. Functional materials analysis using in situ and in operando X-ray and neutron scattering.

    Science.gov (United States)

    Peterson, Vanessa K; Papadakis, Christine M

    2015-03-01

    In situ and in operando studies are commonplace and necessary in functional materials research. This review highlights recent developments in the analysis of functional materials using state-of-the-art in situ and in operando X-ray and neutron scattering and analysis. Examples are given covering a number of important materials areas, alongside a description of the types of information that can be obtained and the experimental setups used to acquire them.

  15. Functional materials analysis using in situ and in operando X-ray and neutron scattering

    Directory of Open Access Journals (Sweden)

    Vanessa K. Peterson

    2015-03-01

    Full Text Available In situ and in operando studies are commonplace and necessary in functional materials research. This review highlights recent developments in the analysis of functional materials using state-of-the-art in situ and in operando X-ray and neutron scattering and analysis. Examples are given covering a number of important materials areas, alongside a description of the types of information that can be obtained and the experimental setups used to acquire them.

  16. Functional materials analysis using in situ and in operando X-ray and neutron scattering

    Science.gov (United States)

    Peterson, Vanessa K.; Papadakis, Christine M.

    2015-01-01

    In situ and in operando studies are commonplace and necessary in functional materials research. This review highlights recent developments in the analysis of functional materials using state-of-the-art in situ and in operando X-ray and neutron scattering and analysis. Examples are given covering a number of important materials areas, alongside a description of the types of information that can be obtained and the experimental setups used to acquire them. PMID:25866665

  17. Final Report LDRD 02-ERD-013 Dense Plasma Characterization by X-ray Thomson Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; Glenzer, S H; Gregori, G; Pollaine, S M; Hammer, J H; Rogers, F; Meezan, N B; Chung, H; Lee, R W

    2005-02-11

    We have successfully demonstrated spectrally-resolved x-ray scattering in a variety of dense plasmas as a powerful new technique for providing microscopic dense plasma parameters unattainable by other means. The results have also been used to distinguish between ionization balance models. This has led to 10 published or to be published papers, 8 invited talks and significant interest from both internal and external experimental plasma physicists and the international statistical plasma physics theory community.

  18. X-ray transmission/scattering technique for thickness-independent density measurement

    Energy Technology Data Exchange (ETDEWEB)

    Giacomelli, E.J.

    1978-12-20

    A nondestructive technique, using penetrating x radiation, has been developed to measure the density uniformity of low-Z, compressible materials that is independent of material thickness. Thickness independence is achieved by simultaneously monitoring the transmitted and scattered x rays. Results on samples of pressed carbon materials have demonstrated that there is the expected linear relationship between measured quantities and material density, independent of material thickness, and that this is a viable means of measuring density uniformity.

  19. On the calculation of x-ray scattering signals from pairwise radial distribution functions

    DEFF Research Database (Denmark)

    Dohn, Asmus Ougaard; Biasin, Elisa; Haldrup, Kristoffer

    2015-01-01

    We derive a formulation for evaluating (time-resolved) x-ray scattering signals of solvated chemical systems, based on pairwise radial distribution functions, with the aim of this formulation to accompany molecular dynamics simulations. The derivation is described in detail to eliminate any...... possible ambiguities, and the result includes a modification to the atom-type formulation which to our knowledge is previously unaccounted for. The formulation is numerically implemented and validated....

  20. Small angle X-ray and neutron scattering from solutions of biological macromolecules

    CERN Document Server

    Svergun, Dmitri I; May, Roland P; Timmins, Peter A

    2013-01-01

    In this book, following the presentation of the basics of scattering from isotropic macromolecular solutions, modern instrumentation, experimental practice and advanced analysis techniques are explained. Advantages of X-rays (rapid data collection, small sample volumes) and of neutrons (contrast variation by hydrogen/deuterium exchange) are specifically highlighted. Examples of applications of the technique to different macromolecular systems are considered with specific emphasis on the synergistic use of SAXS/SANS with other structural, biophysical and computational techniques.

  1. X-ray scattering study of the interplay between magnetism and structure in CeSb

    DEFF Research Database (Denmark)

    McMorrow, Desmond Francis; Lussier, J.-G.; Lebech, Bente

    1997-01-01

    The chemical and magnetic structures of CeSb have been investigated using high-resolution x-ray scattering techniques. Experiments performed in the non-resonant regime (x-ray energy of E = 9.4 keV) showed that when the sample was cooled below its Neel temperature of T-N approximate to 16.5 K, peaks...... appeared with commensurate wave vectors q. From their polarization and wave-vector dependence, the peaks are deduced to arise mainly from a periodic lattice distortion. In the resonant regime, when the x-ray energy was tuned to the L absorption edges of Ce, weak, resonantly enhanced magnetic scattering...... was observed at the L(II) edge (E = 6.164 keV), with no scattering found at either L(I) or L(III) Of the six possible zero-field commensurate magnetic structures reported in earlier neutron experiments, we found the phases with q(m) = 2/3 and 4/7 only, with the domain that has moments perpendicular...

  2. Small angle X-ray scattering studies of reverse micelles in supercritical fluids

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, D.M.; Fulton, J.L.

    1994-10-01

    The nature of aggregates formed in a supercritical fluid determines its solvent power and selectivity. Small angle X-ray scattering (SAXS) is a powerful tool for studying the properties of aggregates with sizes in the 10{angstrom} to 200{angstrom} range. It is also useful in studying those interparticle interactions which operate over a similar distance. The authors have used SAXS to examine the aggregates formed in pure fluids, in mixtures and in fluid/surfactant/water systems. The scattered intensity as a function of angle depends on the geometry, polydispersity, X-ray contrast, and interaction strength of the particles as well as on the phase behavior of the system. In this paper the authors present the results of modeling the X-ray scattering from AOT/water reverse micelles in supercritical propane and in propane/carbon dioxide mixtures. They examine the effect of dilution with CO{sub 2} anti-solvent on the phase behavior of the system and on the strength of intermicellar attractions. A better understanding of these systems must be obtained before the applications of supercritical reverse micelle systems to extractions, reactions, and enhanced oil recovery can be fully developed.

  3. Study of the grazing-incidence X-ray scattering of strongly disturbed fractal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Roshchin, B. S., E-mail: ross@crys.ras.ru; Chukhovsky, F. N.; Pavlyuk, M. D.; Opolchentsev, A. M.; Asadchikov, V. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Research Centre “Crystallography and Photonics” (Russian Federation)

    2017-03-15

    The applicability of different approaches to the description of hard X-ray scattering from rough surfaces is generally limited by a maximum surface roughness height of no more than 1 nm. Meanwhile, this value is several times larger for the surfaces of different materials subjected to treatment, especially in the initial treatment stages. To control the roughness parameters in all stages of surface treatment, a new approach has been developed, which is based on a series expansion of wavefield over the plane eigenstate-function waves describing the small-angle scattering of incident X-rays in terms of plane q-waves propagating through the interface between two media with a random function of relief heights. To determine the amplitudes of reflected and transmitted plane q-waves, a system of two linked integral equations was derived. The solutions to these equations correspond (in zero order) to the well-known Fresnel expressions for a smooth plane interface. Based on these solutions, a statistical fractal model of an isotropic rough interface is built in terms of root-mean-square roughness σ, two-point correlation length l, and fractal surface index h. The model is used to interpret X-ray scattering data for polished surfaces of single-crystal cadmium telluride samples.

  4. Computer simulation tools for X-ray analysis scattering and diffraction methods

    CERN Document Server

    Morelhão, Sérgio Luiz

    2016-01-01

    The main goal of this book is to break down the huge barrier of difficulties faced by beginners from many fields (Engineering, Physics, Chemistry, Biology, Medicine, Material Science, etc.) in using X-rays as an analytical tool in their research. Besides fundamental concepts, MatLab routines are provided, showing how to test and implement the concepts. The major difficult in analyzing materials by X-ray techniques is that it strongly depends on simulation software. This book teaches the users on how to construct a library of routines to simulate scattering and diffraction by almost any kind of samples. It provides to a young student the knowledge that would take more than 20 years to acquire by working on X-rays and relying on the available textbooks. In this book, fundamental concepts in applied X-ray physics are demonstrated through available computer simulation tools. Using MatLab, more than eighty routines are developed for solving the proposed exercises, most of which can be directly used in experimental...

  5. Brownian and advective dynamics in microflow studied by coherent X-ray scattering experiments.

    Science.gov (United States)

    Urbani, Raphael; Westermeier, Fabian; Banusch, Benjamin; Sprung, Michael; Pfohl, Thomas

    2016-11-01

    Combining microfluidics with coherent X-ray illumination offers the possibility to not only measure the structure but also the dynamics of flowing samples in a single-scattering experiment. Here, the power of this combination is demonstrated by studying the advective and Brownian dynamics of colloidal suspensions in microflow of different geometries. Using an experimental setup with a fast two-dimensional detector and performing X-ray correlation spectroscopy by calculating two-dimensional maps of the intensity auto-correlation functions, it was possible to evaluate the sample structure and furthermore to characterize the detailed flow behavior, including flow geometry, main flow directions, advective flow velocities and diffusive dynamics. By scanning a microfocused X-ray beam over a microfluidic device, the anisotropic auto-correlation functions of driven colloidal suspensions in straight, curved and constricted microchannels were mapped with the spatial resolution of the X-ray beam. This method has not only a huge potential for studying flow patterns in complex fluids but also to generally characterize anisotropic dynamics in materials.

  6. Monochromatic x-ray backlighting of wire-array z-pinch plasmas using spherically bent quartz crystals

    Science.gov (United States)

    Sinars, D. B.; Cuneo, M. E.; Bennett, G. R.; Wenger, D. F.; Ruggles, L. E.; Vargas, M. F.; Porter, J. L.; Adams, R. G.; Johnson, D. W.; Keller, K. L.; Rambo, P. K.; Rovang, D. C.; Seamen, H.; Simpson, W. W.; Smith, I. C.; Speas, S. C.

    2003-03-01

    X-ray backlighting systems are being developed to diagnose z-pinch, inertial confinement fusion capsule, and complex hydrodynamics experiments on the 20 MA Sandia Z machine. The x-ray backlighter source is a laser-produced plasma created using the Z-Beamlet laser, a 2 TW, 2 kJ Nd:glass laser recently constructed at Sandia. As an alternative to point-projection radiography, we are investigating a different geometry [S. A. Pikuz et al., Rev. Sci. Instrum. 68, 740 (1997)] that uses spherically bent crystal mirrors to simultaneously obtain high spatial resolution and a narrow spectral bandwidth. Backlighting systems using the Si Heα line (1.865 keV) and the Mn Heα line (6.15 keV) are discussed. These systems are capable of spatial resolutions in the 5-10 μm range, a field of view as large as 5 mm by 20 mm, and a spectral bandwidth comparable to the width of the emission line used for backlighting.

  7. X-ray scattering for the characterization of lyophilized breast tissue samples

    Science.gov (United States)

    Elshemey, Wael M.; Mohamed, Fayrouz S.; Khater, Ibrahim M.

    2013-09-01

    This work investigates the possibility of characterizing breast cancer by measuring the X-ray scattering profiles of lyophilized excised breast tissue samples. Since X-ray scattering from water-rich tissue is dominated by scattering from water, the removal of water by lyophilization would enhance the characterization process. In the present study, X-ray scattering profiles of 22 normal, 22 malignant and 10 benign breast tissue samples are measured. The cut-offs of scatter diagrams, sensitivity, specificity and diagnostic accuracy of three characterization parameters (full width at half maximum (FWHM) for the peak at 1.1 nm-1, area under curve (AUC), and ratio of 1st to 2nd scattering peak intensities (I1/I2%)) are calculated and compared to the data from non-lyophilized samples. Results show increased sensitivity (up to 100%) of the present data on lyophilized breast tissue samples compared to previously reported data for non-lyophilized samples while the specificity (up to 95.4%), diagnostic accuracy (up to 95.4%) and receiver operating characteristic (ROC) curve values (up to 0.9979) for both sets of data are comparable. The present study shows significant differences between normal samples and each of malignant and benign samples. Only subtle differences exist between malignant and benign lyophilized breast tissue samples where FWHM=0.7±0.1 and 0.8±0.3, AUC=1.3±0.2 and 1.4±0.2 and I1/I2%=44.9±11.0 and 52.4±7.6 for malignant and benign samples respectively.

  8. Ultrafast laser-induced melting and ablation studied by time-resolved diffuse X-ray scattering

    Directory of Open Access Journals (Sweden)

    Meyer zu Heringdorf F.

    2013-03-01

    Full Text Available Time-resolved diffuse X-ray scattering with 50 fs, 9.5 keV X-ray pulses from the Linear Coherent Light Source was used to study the structural dynamics in materials undergoing rapid melting and ablation after fs laser excitation.

  9. 1i>s>2p resonant inelastic X-ray scattering combined dipole and quadrupole analysis method

    DEFF Research Database (Denmark)

    Bagger, Alexander; Haarman, Ties; Molina, Anna Puig

    2017-01-01

    In this study an analysis strategy towards using the resonant inelastic X-ray scattering (RIXS) technique more effectively compared with X-ray absorption spectroscopy (XAS) is presented. In particular, the question of when RIXS brings extra information compared with XAS is addressed. To answer th...

  10. Transmission X-ray scattering as a probe for complex liquid-surface structures.

    Science.gov (United States)

    Fukuto, Masafumi; Yang, Lin; Nykypanchuk, Dmytro; Kuzmenko, Ivan

    2016-03-01

    The need for functional materials calls for increasing complexity in self-assembly systems. As a result, the ability to probe both local structure and heterogeneities, such as phase-coexistence and domain morphologies, has become increasingly important to controlling self-assembly processes, including those at liquid surfaces. The traditional X-ray scattering methods for liquid surfaces, such as specular reflectivity and grazing-incidence diffraction, are not well suited to spatially resolving lateral heterogeneities due to large illuminated footprint. A possible alternative approach is to use scanning transmission X-ray scattering to simultaneously probe local intermolecular structures and heterogeneous domain morphologies on liquid surfaces. To test the feasibility of this approach, transmission small- and wide-angle X-ray scattering (TSAXS/TWAXS) studies of Langmuir films formed on water meniscus against a vertically immersed hydrophilic Si substrate were recently carried out. First-order diffraction rings were observed in TSAXS patterns from a monolayer of hexagonally packed gold nanoparticles and in TWAXS patterns from a monolayer of fluorinated fatty acids, both as a Langmuir monolayer on water meniscus and as a Langmuir-Blodgett monolayer on the substrate. The patterns taken at multiple spots have been analyzed to extract the shape of the meniscus surface and the ordered-monolayer coverage as a function of spot position. These results, together with continual improvement in the brightness and spot size of X-ray beams available at synchrotron facilities, support the possibility of using scanning-probe TSAXS/TWAXS to characterize heterogeneous structures at liquid surfaces.

  11. Transmission X-ray scattering as a probe for complex liquid-surface structures

    Energy Technology Data Exchange (ETDEWEB)

    Fukuto, Masafumi; Yang, Lin; Nykypanchuk, Dmytro; Kuzmenko, Ivan

    2016-01-28

    The need for functional materials calls for increasing complexity in self-assembly systems. As a result, the ability to probe both local structure and heterogeneities, such as phase-coexistence and domain morphologies, has become increasingly important to controlling self-assembly processes, including those at liquid surfaces. The traditional X-ray scattering methods for liquid surfaces, such as specular reflectivity and grazing-incidence diffraction, are not well suited to spatially resolving lateral heterogeneities due to large illuminated footprint. A possible alternative approach is to use scanning transmission X-ray scattering to simultaneously probe local intermolecular structures and heterogeneous domain morphologies on liquid surfaces. To test the feasibility of this approach, transmission small- and wide-angle X-ray scattering (TSAXS/TWAXS) studies of Langmuir films formed on water meniscus against a vertically immersed hydrophilic Si substrate were recently carried out. First-order diffraction rings were observed in TSAXS patterns from a monolayer of hexagonally packed gold nanoparticles and in TWAXS patterns from a monolayer of fluorinated fatty acids, both as a Langmuir monolayer on water meniscus and as a Langmuir–Blodgett monolayer on the substrate. The patterns taken at multiple spots have been analyzed to extract the shape of the meniscus surface and the ordered-monolayer coverage as a function of spot position. These results, together with continual improvement in the brightness and spot size of X-ray beams available at synchrotron facilities, support the possibility of using scanning-probe TSAXS/TWAXS to characterize heterogeneous structures at liquid surfaces.

  12. Performance of a micro-strip gas chamber in solution X-ray scattering

    CERN Document Server

    Toyokawa, H; Inoko, Y; Nagayoshi, T; Nishi, Y; Nishikawa, Y; Ochi, A; Suzuki, M; Tanimori, T

    2001-01-01

    The performance of a Micro-Strip Gas Chamber in solution X-ray scattering was studied at the RIKEN structural biology beamline I of the SPring-8 facility. The practical dynamic range was confirmed to be approx 1,000,000 : 1 by measuring S sup - sup 4 decay from a polystyrene latex solution. Steep troughs of scattering profile from an apoferritin solution were clearly obtained without smearing. An unfolding process of a pH jump of cytochrome c was measured. A time resolution of 500 mu s was achieved.

  13. LIGHT SOURCE: TW Laser system for Thomson scattering X-ray light source at Tsinghua University

    Science.gov (United States)

    Yan, Li-Xm; Du, Ying-Chao; Du, Qiang; Li, Ren-Kai; Hua, Jian-Fei; Huang, Wen-Hui; Tang, Chuan-Xiang

    2009-06-01

    A TW (Tera Watt) laser system based on Ti:sapphire mainly for the Tsinghua Thomson scattering X-ray light source (TTX) is being built. Both UV (ultraviolet) laser pulse for driving the photocathode radio-frequency (RF) gun and the IR (infrared) laser pulse as the electron-beam-scattered-light are provided by the system. Efforts have also been made in laser pulse shaping and laser beam transport to optimize the high-brightness electron beam production by the photocathode RF gun.

  14. The promise of resonant inelastic X-ray scattering for modern Kondo physics

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, J.N., E-mail: jason.hancock@uconn.edu [Department of Physics and Institute for Materials Science, University of Connecticut, Storrs 06269, CT (United States); Jarrige, I. [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973-5000 (United States)

    2016-02-15

    Developments in synchrotron accelerator and end station capabilities have brought new techniques to bear on complex matter. The recently enabled technique of resonant inelastic X-ray scattering (RIXS) has emerged as a serious contender of inelastic neutron scattering as a probe of magnetic structure in correlated electronic materials, but can also reveal perspectives on electronic structural not attainable by optical conductivity or angle-resolved photoemission. Here we introduce the basics of this powerful technique and discuss the prospects to turn this probe onto the charge excitations in Kondo lattice systems.

  15. Computational time-resolved and resonant x-ray scattering of strongly correlated materials

    Energy Technology Data Exchange (ETDEWEB)

    Bansil, Arun [Northeastern Univ., Boston, MA (United States)

    2016-11-09

    Basic-Energy Sciences of the Department of Energy (BES/DOE) has made large investments in x-ray sources in the U.S. (NSLS-II, LCLS, NGLS, ALS, APS) as powerful enabling tools for opening up unprecedented new opportunities for exploring properties of matter at various length and time scales. The coming online of the pulsed photon source, literally allows us to see and follow the dynamics of processes in materials at their natural timescales. There is an urgent need therefore to develop theoretical methodologies and computational models for understanding how x-rays interact with matter and the related spectroscopies of materials. The present project addressed aspects of this grand challenge of x-ray science. In particular, our Collaborative Research Team (CRT) focused on developing viable computational schemes for modeling x-ray scattering and photoemission spectra of strongly correlated materials in the time-domain. The vast arsenal of formal/numerical techniques and approaches encompassed by the members of our CRT were brought to bear through appropriate generalizations and extensions to model the pumped state and the dynamics of this non-equilibrium state, and how it can be probed via x-ray absorption (XAS), emission (XES), resonant and non-resonant x-ray scattering, and photoemission processes. We explored the conceptual connections between the time-domain problems and other second-order spectroscopies, such as resonant inelastic x-ray scattering (RIXS) because RIXS may be effectively thought of as a pump-probe experiment in which the incoming photon acts as the pump, and the fluorescent decay is the probe. Alternatively, when the core-valence interactions are strong, one can view K-edge RIXS for example, as the dynamic response of the material to the transient presence of a strong core-hole potential. Unlike an actual pump-probe experiment, here there is no mechanism for adjusting the time-delay between the pump and the probe. However, the core hole

  16. Erratum: Creation of X-Ray Transparency of Matter by Stimulated Elastic Forward Scattering [Phys. Rev. Lett. 115 , 107402 (2015)

    Energy Technology Data Exchange (ETDEWEB)

    Stöhr, J.; Scherz, A.

    2016-01-06

    X-ray absorption by matter has long been described by the famous Beer-Lambert law. Here we show how this fundamental law needs to be modified for high-intensity coherent x-ray pulses, now available at x-ray free electron lasers, due to the onset of stimulated elastic forward scattering. We present an analytical expression for the modified polarization-dependent Beer-Lambert law for the case of resonant core-to-valence electronic transitions and incident transform limited x-ray pulses. Upon transmission through a solid, the absorption and dichroic contrasts are found to vanish with increasing x-ray intensity, with the stimulation threshold lowered by orders of magnitude through a super-radiative coherent effect. Our results have broad implications for the study of matter with x-ray lasers.

  17. Precision mechanical structure of an ultra-high-resolution spectrometer for inelastic X-ray scattering instrument

    Science.gov (United States)

    Shu, Deming; Shvydko, Yuri; Stoupin, Stanislav A.; Khachatryan, Ruben; Goetze, Kurt A.; Roberts, Timothy

    2015-04-14

    A method and an ultrahigh-resolution spectrometer including a precision mechanical structure for positioning inelastic X-ray scattering optics are provided. The spectrometer includes an X-ray monochromator and an X-ray analyzer, each including X-ray optics of a collimating (C) crystal, a pair of dispersing (D) element crystals, anomalous transmission filter (F) and a wavelength (W) selector crystal. A respective precision mechanical structure is provided with the X-ray monochromator and the X-ray analyzer. The precision mechanical structure includes a base plate, such as an aluminum base plate; positioning stages for D-crystal alignment; positioning stages with an incline sensor for C/F/W-crystal alignment, and the positioning stages including flexure-based high-stiffness structure.

  18. Polarized soft X-ray scattering reveals differences in chain orientation within block copolymer lamellae

    Science.gov (United States)

    Litofsky, Joshua; Le, Thinh; Aplan, Melissa; Lee, Youngmin; Gomez, Enrique

    Fully conjugated block copolymers can serve as the active layer in organic photovoltaics (OPV) and other organic electronic devices. The use of Resonant Soft X-Ray Scattering (RSoXS) allows for studies into the molecular orientation and domain spacing of the polymers within lamellae by tuning the X-ray energy and polarization to examine various components of block copolymers. Using the conjugated block copolymer system of poly(3-hexylthiophene)-block-poly((9,9-dioctylfluorene)-2,7-diyl-alt-[4,7-bis(thiophen-5-yl)-2,1,3-benzothiadiazole]-2',2''-diyl), P3HT-b-PFTBT, and PFTBT derivatives, we can examine the effects of various polymer blocks on the differences of morphology between the donor and acceptor. Polarized Soft X-Ray Scattering (PSoXS) allows us to quantify the type and the degree of orientation of chains within block copolymer domains in thin films. Our work suggests that within our conjugated block copolymers, the P3HT chains orient parallel to the block copolymer interface. Furthermore, examining the anisotropy in PSoXS data provides a clear signature of the block copolymer microstructure, confirming the domain spacing extracted from PSoXS scales with the end-to-end distance of the blocks.

  19. X-ray scatter correction method for dedicated breast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sechopoulos, Ioannis [Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University School of Medicine, 1701 Upper Gate Drive NE, Suite 5018, Atlanta, Georgia 30322 (United States)

    2012-05-15

    Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to

  20. Magnetic effects on the resonant inelastic soft X-ray scattering in the transition metal oxides

    Energy Technology Data Exchange (ETDEWEB)

    Grebennikov, V.I. E-mail: greben@imp.uran.ru

    2003-03-01

    Applications of resonant inelastic soft X-ray scattering for studying magnetic systems are discussed. The emission spectra show the magnetic circular dichroism when they are excited by the polarized incident X-ray radiation. A theoretical description for L{alpha} and L{beta} emission spectra recorded at different excitation photon energies gives the main spectral lines: a normal emission peak, with the constant energy, and a quasi-elastic peak that moves in energy scale when the incident photon energy changes. The intensity of the quasi-elastic peak is strongly controlled by valence electron excitations due to core-hole effects. The emission experiments contain information on the atomic magnetic moment values in the case of depolarized incident radiation and in disordered magnetic states. The integral intensities ratio for L{beta}/L{alpha} lines in transition metal oxides are analyzed from this point of view.

  1. Ultra-high-resolution inelastic X-ray scattering at high-repetition-rate self-seeded X-ray free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Chubar, Oleg [Brookhaven National Laboratory, Upton, NY 11973 (United States); Geloni, Gianluca [European X-ray Free-Electron Laser, Albert-Einstein-Ring 19, 22761 Hamburg (Germany); Kocharyan, Vitali [Deutsches Elektronen-Synchrotron, 22761 Hamburg (Germany); Madsen, Anders [European X-ray Free-Electron Laser, Albert-Einstein-Ring 19, 22761 Hamburg (Germany); Saldin, Evgeni; Serkez, Svitozar [Deutsches Elektronen-Synchrotron, 22761 Hamburg (Germany); Shvyd’ko, Yuri, E-mail: shvydko@aps.anl.gov [Argonne National Laboratory, Argonne, IL 60439 (United States); Sutter, John [Diamond Light Source Ltd, Didcot OX11 0DE (United Kingdom)

    2016-02-12

    This article explores novel opportunities for ultra-high-resolution inelastic X-ray scattering (IXS) at high-repetition-rate self-seeded XFELs. These next-generation light sources are promising a more than three orders of magnitude increase in average spectral flux compared with what is possible with storage-ring-based radiation sources. In combination with the advanced IXS spectrometer described here, this may become a real game-changer for ultra-high-resolution X-ray spectroscopies, and hence for the studies of dynamics in condensed matter systems. Inelastic X-ray scattering (IXS) is an important tool for studies of equilibrium dynamics in condensed matter. A new spectrometer recently proposed for ultra-high-resolution IXS (UHRIX) has achieved 0.6 meV and 0.25 nm{sup −1} spectral and momentum-transfer resolutions, respectively. However, further improvements down to 0.1 meV and 0.02 nm{sup −1} are required to close the gap in energy–momentum space between high- and low-frequency probes. It is shown that this goal can be achieved by further optimizing the X-ray optics and by increasing the spectral flux of the incident X-ray pulses. UHRIX performs best at energies from 5 to 10 keV, where a combination of self-seeding and undulator tapering at the SASE-2 beamline of the European XFEL promises up to a 100-fold increase in average spectral flux compared with nominal SASE pulses at saturation, or three orders of magnitude more than what is possible with storage-ring-based radiation sources. Wave-optics calculations show that about 7 × 10{sup 12} photons s{sup −1} in a 90 µeV bandwidth can be achieved on the sample. This will provide unique new possibilities for dynamics studies by IXS.

  2. X-ray Intermolecular Structure Factor ( XISF ): separation of intra- and intermolecular interactions from total X-ray scattering data

    Energy Technology Data Exchange (ETDEWEB)

    Mou, Q.; Benmore, C. J.; Yarger, J. L.

    2015-05-09

    XISFis a MATLAB program developed to separate intermolecular structure factors from total X-ray scattering structure factors for molecular liquids and amorphous solids. The program is built on a trust-region-reflective optimization routine with the r.m.s. deviations of atoms physically constrained.XISFhas been optimized for performance and can separate intermolecular structure factors of complex molecules.

  3. Soft X-ray synchrotron radiation investigations of actinidematerials systems utilizing X-ray emission spectroscopy and resonantinelastic X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Shuh, D.K.; Butorin, S.M.; Guo, J.-H.; Nordgren, J.

    2004-01-03

    Synchrotron radiation (SR) methods have been utilized with increasing frequency over the past several years to study topics in actinide science, ranging from those of a fundamental nature to those that address a specifically-targeted technical need. In particular, the emergence of microspectroscopic and fluorescence-based techniques have permitted investigations of actinide materials at sources of soft x-ray SR. Spectroscopic techniques with fluorescence-based detection are useful for actinide investigations since they are sensitive to small amounts of material and the information sampling depth may be varied. These characteristics also serve to simplify both sample preparation and safety considerations. Examples of investigations using these fluorescence techniques will be described along with their results, as well as the prospects for future investigations utilizing these methodologies.

  4. Variegate galaxy cluster gas content: Mean fraction, scatter, selection effects, and covariance with X-ray luminosity

    Science.gov (United States)

    Andreon, S.; Wang, J.; Trinchieri, G.; Moretti, A.; Serra, A. L.

    2017-10-01

    We use a cluster sample selected independently of the intracluster medium content with reliable masses to measure the mean gas mass fraction and its scatter, the biases of the X-ray selection on gas mass fraction, and the covariance between the X-ray luminosity and gas mass. The sample is formed by 34 galaxy clusters in the nearby (0.050 sample allows us to unveil a variegate population of clusters; the gas mass fraction shows a scatter of 0.17 ± 0.04 dex, possibly indicating a quite variable amount of feedback from cluster to cluster, which is larger than is found in previous samples targeting subpopulations of galaxy clusters, such as relaxed or X-ray bright clusters. The similarity of the gas density profiles induces an almost scatterless relation between X-ray luminosity, gas mass, and halo mass, and modulates selection effects in the halo gas mass fraction: gas-rich clusters are preferentially included in X-ray selected samples. The almost scatterless relation also fixes the relative scatters and slopes of the LX-M and Mgas-M relations and makes core-excised X-ray luminosities and gas masses fully covariant. Therefore, cosmological or astrophysical studies involving X-ray or SZ selected samples need to account for both selection effects and covariance of the studied quantities with X-ray luminosity/SZ strength.

  5. Interior tomographic imaging for x-ray coherent scattering (Conference Presentation)

    Science.gov (United States)

    Pang, Sean; Zhu, Zheyuan

    2017-05-01

    Conventional computed tomography reconstructs the attenuation only high-dimensional images. Coherent scatter computed tomography, which reconstructs the angular dependent scattering profiles of 3D objects, can provide molecular signatures that improves the accuracy of material identification and classification. Coherent scatter tomography are traditionally acquired by setups similar to x-ray powder diffraction machine; a collimated source in combination with 2D or 1D detector collimation in order to localize the scattering point. In addition, the coherent scatter cross-section is often 3 orders of magnitude lower than that of the absorption cross-section for the same material. Coded aperture and structured illumination approaches has been shown to greatly improve the collection efficiency. In many applications, especially in security imaging and medical diagnosis, fast and accurate identification of the material composition of a small volume within the whole object would lead to an accelerated imaging procedure and reduced radiation dose. Here, we report an imaging method to reconstruct the material coherent scatter profile within a small volume. The reconstruction along one radial direction can reconstruct a scalar coherent scattering tomographic image. Our methods takes advantage of the finite support of the scattering profile in small angle regime. Our system uses a pencil beam setup without using any detector side collimation. Coherent scatter profile of a 10 mm scattering sample embedded in a 30 mm diameter phantom was reconstructed. The setup has small form factor and is suitable for various portable non-destructive detection applications.

  6. A software-based x-ray scatter correction method for breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jia Feng, Steve Si; Sechopoulos, Ioannis [Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, and Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 (United States); Department of Radiology and Imaging Sciences, Hematology and Medical Oncology and Winship Cancer Institute, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 (United States)

    2011-12-15

    Purpose: To develop a software-based scatter correction method for digital breast tomosynthesis (DBT) imaging and investigate its impact on the image quality of tomosynthesis reconstructions of both phantoms and patients. Methods: A Monte Carlo (MC) simulation of x-ray scatter, with geometry matching that of the cranio-caudal (CC) view of a DBT clinical prototype, was developed using the Geant4 toolkit and used to generate maps of the scatter-to-primary ratio (SPR) of a number of homogeneous standard-shaped breasts of varying sizes. Dimension-matched SPR maps were then deformed and registered to DBT acquisition projections, allowing for the estimation of the primary x-ray signal acquired by the imaging system. Noise filtering of the estimated projections was then performed to reduce the impact of the quantum noise of the x-ray scatter. Three dimensional (3D) reconstruction was then performed using the maximum likelihood-expectation maximization (MLEM) method. This process was tested on acquisitions of a heterogeneous 50/50 adipose/glandular tomosynthesis phantom with embedded masses, fibers, and microcalcifications and on acquisitions of patients. The image quality of the reconstructions of the scatter-corrected and uncorrected projections was analyzed by studying the signal-difference-to-noise ratio (SDNR), the integral of the signal in each mass lesion (integrated mass signal, IMS), and the modulation transfer function (MTF). Results: The reconstructions of the scatter-corrected projections demonstrated superior image quality. The SDNR of masses embedded in a 5 cm thick tomosynthesis phantom improved 60%-66%, while the SDNR of the smallest mass in an 8 cm thick phantom improved by 59% (p < 0.01). The IMS of the masses in the 5 cm thick phantom also improved by 15%-29%, while the IMS of the masses in the 8 cm thick phantom improved by 26%-62% (p < 0.01). Some embedded microcalcifications in the tomosynthesis phantoms were visible only in the scatter

  7. Investigations of Silk Fibers Using X-Ray Scattering and Atomic Force Microscopy

    Science.gov (United States)

    Miller, Lance D.; Putthanarat, Sirina; Eby, Ronald K.; Adams, W. W.; Liu, G. F.

    1998-03-01

    Silk fibers from the cocoon of Bombyx mori and the dragline of Nephila clavipes have been investigated by small angle x-ray scattering (SAXS) and atomic force microscopy (AFM). The large scale morphology of these silks have minimum scattering dimensions, and correlation length on the order of 150-300 nm. Several types of AFM measurements on peeled and abraided silk samples have revealed dimensions in agreement with SAXS results. Further agreemeent has been found through the incorporation of discrete Fourier transform theory on AFM topographic information as compared to SAXS patterns. This incorporation allows the materials scientist a way of visualizing the relationship between a material and its resulting scattering function. All of these studies yield a more complete view of the silk morphology and give a new method of model building from scattering experiments.

  8. Planar small-angle x-ray scattering imaging of phantoms and biological samples

    Science.gov (United States)

    Choi, M.; Badano, A.

    2017-04-01

    Coherent small-angle x-ray scattering (SAXS) provides molecular and nanometer-scale structural information. By capturing SAXS data at multiple locations across a sample, we obtained planar images and observed improved contrast given by the difference in the material scattering cross sections. We use phantoms made with 3D printing techniques, with tissue-mimicking plastic (PMMA), and with a highly scattering reference material (AgBe), which were chosen because of their well characterized scattering cross section to demonstrate and characterize the planar imaging of a laboratory SAXS system. We measure 1.07 and 2.14 nm-1 angular intensity maps for AgBe, 9.5 nm-1 for PMMA, and 12.3 nm-1 for Veroclear. The planar SAXS images show material discrimination based on their cross sectional features. The image signal-to-noise ratio (SNR) of each q image was dependent on exposure time and x-ray flux. We observed a lower SNR (91 ± 48) at q angles where no characteristic peaks for either material exist. To improve the visualization of the acquired data by utilizing all q-binned data, we describe a weighted-sum presentation method with a priori knowledge of relevant cross sections to improve the SNR (10 000 ± 6400) over the SNR from a single q-image at 1.07 nm-1 (1100 ± 620). In addition, we describe planar SAXS imaging of a mouse brain slice showing differentiation of tissue types as compared to a conventional absorption-based x-ray imaging technique.

  9. Accelerated x-ray scatter projection imaging using multiple continuously moving pencil beams

    Science.gov (United States)

    Dydula, Christopher; Belev, George; Johns, Paul C.

    2017-03-01

    Coherent x-ray scatter varies with angle and photon energy in a manner dependent on the chemical composition of the scattering material, even for amorphous materials. Therefore, images generated from scattered photons can have much higher contrast than conventional projection radiographs. We are developing a scatter projection imaging prototype at the BioMedical Imaging and Therapy (BMIT) facility of the Canadian Light Source (CLS) synchrotron in Saskatoon, Canada. The best images are obtained using step-and-shoot scanning with a single pencil beam and area detector to capture sequentially the scatter pattern for each primary beam location on the sample. Primary x-ray transmission is recorded simultaneously using photodiodes. The technological challenge is to acquire the scatter data in a reasonable time. Using multiple pencil beams producing partially-overlapping scatter patterns reduces acquisition time but increases complexity due to the need for a disentangling algorithm to extract the data. Continuous sample motion, rather than step-and-shoot, also reduces acquisition time at the expense of introducing motion blur. With a five-beam (33.2 keV, 3.5 mm2 beam area) continuous sample motion configuration, a rectangular array of 12 x 100 pixels with 1 mm sampling width has been acquired in 0.4 minutes (3000 pixels per minute). The acquisition speed is 38 times the speed for single beam step-and-shoot. A system model has been developed to calculate detected scatter patterns given the material composition of the object to be imaged. Our prototype development, image acquisition of a plastic phantom and modelling are described.

  10. Field control of single x-ray photons in nuclear forward scattering

    CERN Document Server

    Kong, Xiangjin; Pálffy, Adriana

    2013-01-01

    Means to coherently control single x-ray photons in resonant scattering of light off nuclei by electric or magnetic fields are investigated theoretically. In order to derive the time response in nuclear forward scattering, we adapt the Maxwell-Bloch equations known from quantum optics to describe the resonant light pulse propagation through a nuclear medium. Two types of time-dependent perturbations of nuclear forward scattering are considered for coherent control of the resonantly scattered x-ray quanta. First, the simultaneous coherent propagation of two pulses through the nuclear sample is addressed. We find that the signal of a weak pulse can be enhanced or suppressed by a stronger pulse simultaneously propagating through the sample in counter-propagating geometry. Second, the effect of a time-dependent hyperfine splitting is investigated and we put forward a scheme that allows parts of the spectrum to be shifted forward in time. This is the inverse effect of coherent photon storage and may become a valua...

  11. Deterministic simulation of first-order scattering in virtual X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Freud, N. E-mail: nicolas.freud@insa-lyon.fr; Duvauchelle, P.; Pistrui-Maximean, S.A.; Letang, J.-M.; Babot, D

    2004-07-01

    A deterministic algorithm is proposed to compute the contribution of first-order Compton- and Rayleigh-scattered radiation in X-ray imaging. This algorithm has been implemented in a simulation code named virtual X-ray imaging. The physical models chosen to account for photon scattering are the well-known form factor and incoherent scattering function approximations, which are recalled in this paper and whose limits of validity are briefly discussed. The proposed algorithm, based on a voxel discretization of the inspected object, is presented in detail, as well as its results in simple configurations, which are shown to converge when the sampling steps are chosen sufficiently small. Simple criteria for choosing correct sampling steps (voxel and pixel size) are established. The order of magnitude of the computation time necessary to simulate first-order scattering images amounts to hours with a PC architecture and can even be decreased down to minutes, if only a profile is computed (along a linear detector). Finally, the results obtained with the proposed algorithm are compared to the ones given by the Monte Carlo code Geant4 and found to be in excellent accordance, which constitutes a validation of our algorithm. The advantages and drawbacks of the proposed deterministic method versus the Monte Carlo method are briefly discussed.

  12. Compton scattering artifacts in electron excited X-ray spectra measured with a silicon drift detector.

    Science.gov (United States)

    Ritchie, Nicholas W M; Newbury, Dale E; Lindstrom, Abigail P

    2011-12-01

    Artifacts are the nemesis of trace element analysis in electron-excited energy dispersive X-ray spectrometry. Peaks that result from nonideal behavior in the detector or sample can fool even an experienced microanalyst into believing that they have trace amounts of an element that is not present. Many artifacts, such as the Si escape peak, absorption edges, and coincidence peaks, can be traced to the detector. Others, such as secondary fluorescence peaks and scatter peaks, can be traced to the sample. We have identified a new sample-dependent artifact that we attribute to Compton scattering of energetic X-rays generated in a small feature and subsequently scattered from a low atomic number matrix. It seems likely that this artifact has not previously been reported because it only occurs under specific conditions and represents a relatively small signal. However, with the advent of silicon drift detectors and their utility for trace element analysis, we anticipate that more people will observe it and possibly misidentify it. Though small, the artifact is not inconsequential. Under some conditions, it is possible to mistakenly identify the Compton scatter artifact as approximately 1% of an element that is not present.

  13. Small-angle X-ray scattering studies of adsorption in Vycor glass.

    Science.gov (United States)

    Mitropoulos, A Ch

    2009-08-15

    Porous Vycor is examined by measuring CH(2)Br(2) adsorption in situ with small-angle X-ray scattering. When a class of pores fills with condensed vapors of this particular adsorbate it ceases to act as scatterer and only the remaining empty pores produce a measurable intensity. By determining a number of scattering curves at various relative pressure loadings details on the structure of the glass as well as on the adsorption/desorption mechanism are obtained. Pore chord length and specific surface area are estimated from Porod tangent analysis to 78 A and 108 m(2)/g. Comparison of the results with those reported for N(2) and Ar adsorption is also given. The role of network effects on the shape of the hysteresis loop is considered and the pore-blocking hypothesis is verified from the scattering spectra. The pore connectivity is calculated to 5.6. The X-ray data are further treated with the inverse Fourier transformation technique. Pore-size distributions are extracted and weighed against the prediction of the Kelvin equation.

  14. Structural Significance of Lipid Diversity as Studied by Small Angle Neutron and X-ray Scattering.

    Science.gov (United States)

    Kučerka, Norbert; Heberle, Frederick A; Pan, Jianjun; Katsaras, John

    2015-09-21

    We review recent developments in the rapidly growing field of membrane biophysics, with a focus on the structural properties of single lipid bilayers determined by different scattering techniques, namely neutron and X-ray scattering. The need for accurate lipid structural properties is emphasized by the sometimes conflicting results found in the literature, even in the case of the most studied lipid bilayers. Increasingly, accurate and detailed structural models require more experimental data, such as those from contrast varied neutron scattering and X-ray scattering experiments that are jointly refined with molecular dynamics simulations. This experimental and computational approach produces robust bilayer structural parameters that enable insights, for example, into the interplay between collective membrane properties and its components (e.g., hydrocarbon chain length and unsaturation, and lipid headgroup composition). From model studies such as these, one is better able to appreciate how a real biological membrane can be tuned by balancing the contributions from the lipid's different moieties (e.g., acyl chains, headgroups, backbones, etc.).

  15. Structural Significance of Lipid Diversity as Studied by Small Angle Neutron and X-ray Scattering

    Directory of Open Access Journals (Sweden)

    Norbert Kučerka

    2015-09-01

    Full Text Available We review recent developments in the rapidly growing field of membrane biophysics, with a focus on the structural properties of single lipid bilayers determined by different scattering techniques, namely neutron and X-ray scattering. The need for accurate lipid structural properties is emphasized by the sometimes conflicting results found in the literature, even in the case of the most studied lipid bilayers. Increasingly, accurate and detailed structural models require more experimental data, such as those from contrast varied neutron scattering and X-ray scattering experiments that are jointly refined with molecular dynamics simulations. This experimental and computational approach produces robust bilayer structural parameters that enable insights, for example, into the interplay between collective membrane properties and its components (e.g., hydrocarbon chain length and unsaturation, and lipid headgroup composition. From model studies such as these, one is better able to appreciate how a real biological membrane can be tuned by balancing the contributions from the lipid’s different moieties (e.g., acyl chains, headgroups, backbones, etc..

  16. Probing orbital symmetry in solution: polarization-dependent resonant inelastic soft x-ray scattering on liquid micro-jet

    Science.gov (United States)

    Dierker, B.; Suljoti, E.; Atak, K.; Lange, K. M.; Engel, N.; Golnak, R.; Dantz, M.; Hodeck, K.; Khan, M.; Kosugi, N.; Aziz, E. F.

    2013-09-01

    Polarization-dependent resonant inelastic x-ray scattering is demonstrated here for liquid acetonitrile, acetone and dimethyl sulfoxide, using the liquid micro-jet technique. Selective excitation to an unoccupied orbital with a specific symmetry at the K-edge x-ray absorption of liquid samples determines the polarization-dependent emission of the occupied states. Considering the well-defined unoccupied molecular orbital configuration and utilizing the results of ab initio molecular orbital calculations, the polarization-dependent anisotropy in resonant inelastic soft x-ray scattering is discussed in a membrane-free configuration.

  17. Pinhole-type two-dimensional ultra-small-angle X-ray scattering on the micrometer scale

    Energy Technology Data Exchange (ETDEWEB)

    Kishimoto, Hiroyuki, E-mail: h-kishimoto.az@srigroup.co.jp [Sumitomo Rubber Industries Ltd, 2-1-1 Tsutsui, Chuo, Kobe, Hyogo 651-0071 (Japan); The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Shinohara, Yuya, E-mail: h-kishimoto.az@srigroup.co.jp [The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Suzuki, Yoshio; Takeuchi, Akihisa; Yagi, Naoto [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan); Amemiya, Yoshiyuki [The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan)

    2013-11-02

    A pinhole-type ultra-small-angle X-ray scattering set-up that enlarges the accessible q-range to 0.25 µm{sup −1} is described. A pinhole-type two-dimensional ultra-small-angle X-ray scattering set-up at a so-called medium-length beamline at SPring-8 is reported. A long sample-to-detector distance, 160.5 m, can be used at this beamline and a small-angle resolution of 0.25 µm{sup −1} was thereby achieved at an X-ray energy of 8 keV.

  18. The structure and dynamics of thin poly(styrene)-b-(polybutadiene) copolymer films studied by x-ray scattering

    Science.gov (United States)

    Song, Sanghoon; Byun, Youngsuk; Kim, Jeeun; Eom, Daeyong; Cha, Wonsuk; Kim, Hyunjung

    2007-03-01

    We have investigated the structure and dynamics of thin diblock copolymer films of poly(styrene)-b-poly(butadiene) using x-ray reflectivity, diffuse scattering, grazing incidence small angle scattering (GISAXS), and x-ray photon correlation spectroscopy (XPCS), respectively. The measurements were performed at temperatures below and above the order-disorder transition temperature (ODT) of bulk with different film thicknesses. The x-ray reflectivity and GISAXS results show that the structural changes appear at lower temperature than ODT of bulk. These results will be discussed with the findings from the XPCS.

  19. X-ray Raman scattering from the carbon K edge in polymerized C sub 6 sub 0 : experiment and theory

    CERN Document Server

    Rueff, J P; Bartolomé, F; Krisch, M; Hodeau, J L; Marques, L; Mezouar, M; Kaprolat, A; Lorenzen, M; Sette, F

    2002-01-01

    The carbon K near-edge absorption spectra of one- and two-dimensional polymerized C sub 6 sub 0 have been investigated by non-resonant inelastic scattering in the hard-x-ray regime. The observed changes in the spectra are in good agreement with simulations based on an ab initio approach using the finite-difference method, and confirm the [2 + 2] cyclo-addition picture. Our results demonstrate the value of inelastic x-ray scattering as a bulk probe of electronic structure in systems that are difficult to study with conventional x-ray absorption techniques.

  20. Study of human blood and hemocomponents irradiated by low angle x ray scattering (LAXS)

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Nivia G. Villela; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada e Termodinamica], e-mail: nitatag@gmail.com; Mota, Carla L.S.; Almeida, Andre P.; Azeredo, Soraia R.; Braz, Delson [Coordenacao dos Programas de Pos-graduacao em Engenharia (COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear], e-mail: delson@lin.ufrj.br

    2009-07-01

    Irradiation of blood and blood components is currently practiced in developed and in a few developing countries. The main purpose of this process is the prevention of graft versus host disease in immunodeficient patients. The Food and Drug Administration recommends a dose range of 15 Gy to 25 Gy for these blood components. When x-ray photons are scattered from biological samples, their angular distribution shows one or more peaks in the forward direction of scattering. These peaks are characteristic for the investigated samples. Due to its wide range of biological and medical applications, low-angle x-ray scattering has attracted the attention of many authors. Thus in this present work was studied the possible variations in scattering profiles due to the irradiation when the gender of patients was considered. Fresh blood specimens were obtained from volunteers using vacutainer tubes containing EDTA, at the Dr. Eliel Figueiredo Laboratory, Rio de Janeiro. All the samples were lyophilized for 48 hours in a freeze drier in order to remove the water. The scattering measurements were carried out in e-2e reflection geometry using a powder diffractometer Shimadzu XRD- 6000. The measured characterization parameters for LAXS were associated with epidemiological data (gender). The mean values of the different parameters were compared using the Students's t-test for each characterization parameters. The scattering profiles from plasma and formed elements are characterized by the presence of two peaks in the forward direction of scattering. For epidemiological data (gender) analyzed was not found significant changes in the mostly of characterization parameters (p>0.05). (author)

  1. X-Ray Thomson Scattering and Radiography from Spherical Implosions on the OMEGA Laser

    Science.gov (United States)

    Saunders, A. M.; Laziki-Jenei, A.; Doeppner, T.; Landen, O. L.; MacDonald, M.; Nilsen, J.; Swift, D.; Falcone, R. W.

    2017-10-01

    X-ray Thomson scattering (XRTS) is an experimental technique that directly probes the physics of warm dense matter by measuring electron density, electron temperature, and ionization state. XRTS in combination with x-ray radiography offers a unique ability to measure an absolute equation of state (EOS) from material under compression. Recent experiments highlight uncertainties in EOS models and the predicted ionization of compressed matter, suggesting more validation of models is needed. We present XRTS and x-ray radiography measurements taken at the OMEGA Laser Facility from directly-driven solid carbon spheres at densities on the order of 1x1024 g cm-3 and temperatures on the order of 30 eV. The results shed light on the equations of state of matter under compression. This work performed under auspices of the US Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344 and under the Stewardship Science Graduate Fellowship, Grant Number DE- NA0002135.

  2. A short-pulse X-ray beamline for spectroscopy and scattering.

    Science.gov (United States)

    Reininger, R; Dufresne, E M; Borland, M; Beno, M A; Young, L; Evans, P G

    2014-09-01

    Experimental facilities for picosecond X-ray spectroscopy and scattering based on RF deflection of stored electron beams face a series of optical design challenges. Beamlines designed around such a source enable time-resolved diffraction, spectroscopy and imaging studies in chemical, condensed matter and nanoscale materials science using few-picosecond-duration pulses possessing the stability, high repetition rate and spectral range of synchrotron light sources. The RF-deflected chirped electron beam produces a vertical fan of undulator radiation with a correlation between angle and time. The duration of the X-ray pulses delivered to experiments is selected by a vertical aperture. In addition to the radiation at the fundamental photon energy in the central cone, the undulator also emits the same photon energy in concentric rings around the central cone, which can potentially compromise the time resolution of experiments. A detailed analysis of this issue is presented for the proposed SPXSS beamline for the Advanced Photon Source. An optical design that minimizes the effects of off-axis radiation in lengthening the duration of pulses and provides variable X-ray pulse duration between 2.4 and 16 ps is presented.

  3. The accurate assessment of small-angle X-ray scattering data

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Thomas D. [Hauptman–Woodward Medical Research Institute, 700 Ellicott Street, Buffalo, NY 14203 (United States); Luft, Joseph R. [Hauptman–Woodward Medical Research Institute, 700 Ellicott Street, Buffalo, NY 14203 (United States); SUNY Buffalo, 700 Ellicott Street, Buffalo, NY 14203 (United States); Carter, Lester G.; Matsui, Tsutomu; Weiss, Thomas M.; Martel, Anne [Stanford Synchrotron Radiation Lightsource, 2575 Sand Hill Road, MS69, Menlo Park, CA 94025 (United States); Snell, Edward H., E-mail: esnell@hwi.buffalo.edu [Hauptman–Woodward Medical Research Institute, 700 Ellicott Street, Buffalo, NY 14203 (United States); SUNY Buffalo, 700 Ellicott Street, Buffalo, NY 14203 (United States)

    2015-01-01

    A set of quantitative techniques is suggested for assessing SAXS data quality. These are applied in the form of a script, SAXStats, to a test set of 27 proteins, showing that these techniques are more sensitive than manual assessment of data quality. Small-angle X-ray scattering (SAXS) has grown in popularity in recent times with the advent of bright synchrotron X-ray sources, powerful computational resources and algorithms enabling the calculation of increasingly complex models. However, the lack of standardized data-quality metrics presents difficulties for the growing user community in accurately assessing the quality of experimental SAXS data. Here, a series of metrics to quantitatively describe SAXS data in an objective manner using statistical evaluations are defined. These metrics are applied to identify the effects of radiation damage, concentration dependence and interparticle interactions on SAXS data from a set of 27 previously described targets for which high-resolution structures have been determined via X-ray crystallography or nuclear magnetic resonance (NMR) spectroscopy. The studies show that these metrics are sufficient to characterize SAXS data quality on a small sample set with statistical rigor and sensitivity similar to or better than manual analysis. The development of data-quality analysis strategies such as these initial efforts is needed to enable the accurate and unbiased assessment of SAXS data quality.

  4. Protein folding and protein metallocluster studies using synchrotron small angler X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Eliezer, D.

    1994-06-01

    Proteins, biological macromolecules composed of amino-acid building blocks, possess unique three dimensional shapes or conformations which are intimately related to their biological function. All of the information necessary to determine this conformation is stored in a protein`s amino acid sequence. The problem of understanding the process by which nature maps protein amino-acid sequences to three-dimensional conformations is known as the protein folding problem, and is one of the central unsolved problems in biophysics today. The possible applications of a solution are broad, ranging from the elucidation of thousands of protein structures to the rational modification and design of protein-based drugs. The scattering of X-rays by matter has long been useful as a tool for the characterization of physical properties of materials, including biological samples. The high photon flux available at synchrotron X-ray sources allows for the measurement of scattering cross-sections of dilute and/or disordered samples. Such measurements do not yield the detailed geometrical information available from crystalline samples, but do allow for lower resolution studies of dynamical processes not observable in the crystalline state. The main focus of the work described here has been the study of the protein folding process using time-resolved small-angle x-ray scattering measurements. The original intention was to observe the decrease in overall size which must accompany the folding of a protein from an extended conformation to its compact native state. Although this process proved too fast for the current time-resolution of the technique, upper bounds were set on the probable compaction times of several small proteins. In addition, an interesting and unexpected process was detected, in which the folding protein passes through an intermediate state which shows a tendency to associate. This state is proposed to be a kinetic molten globule folding intermediate.

  5. X-ray crystal structure and small-angle X-ray scattering of sheep liver sorbitol dehydrogenase

    DEFF Research Database (Denmark)

    Yennawar, Hemant; Møller, Magda; Gillilan, Richard

    2011-01-01

    The X-ray crystal structure of sheep liver sorbitol dehydrogenase (slSDH) has been determined using the crystal structure of human sorbitol dehydrogenase (hSDH) as a molecular-replacement model. slSDH crystallized in space group I222 with one monomer in the asymmetric unit. A conserved tetramer...... that superposes well with that seen in hSDH (despite belonging to a different space group) and obeying the 222 crystal symmetry is seen in slSDH. An acetate molecule is bound in the active site, coordinating to the active-site zinc through a water molecule. Glycerol, a substrate of slSDH, also occupies...... the substrate-binding pocket together with the acetate designed by nature to fit large polyol substrates. The substrate-binding pocket is seen to be in close proximity to the tetramer interface, which explains the need for the structural integrity of the tetramer for enzyme activity. Small-angle X...

  6. On the possibility of using X-ray Compton scattering to study magnetoelectrical properties of crystals

    Energy Technology Data Exchange (ETDEWEB)

    Collins, S. P., E-mail: steve.collins@diamond.ac.uk; Laundy, D.; Connolley, T.; Laan, G. van der; Fabrizi, F. [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot, OX11 0DE (United Kingdom); Janssen, O. [Department of Physics, New York University, New York, NY 10003 (United States); Cooper, M. J. [Department of Physics, University of Warwick, CV4 7AL (United Kingdom); Ebert, H.; Mankovsky, S. [Universität München, Department Chemie, Haus E2.033, Butenandtstrasse 5-13, D-81377 München (Germany)

    2016-02-16

    The possibility of using X-ray Compton scattering to reveal antisymmetric components of the electron momentum density, as a fingerprint of magnetoelectric sample properties, is investigated experimentally and theoretically by studying the polar ferromagnet GaFeO{sub 3}. This paper discusses the possibility of using Compton scattering – an inelastic X-ray scattering process that yields a projection of the electron momentum density – to probe magnetoelectrical properties. It is shown that an antisymmetric component of the momentum density is a unique fingerprint of such time- and parity-odd physics. It is argued that polar ferromagnets are ideal candidates to demonstrate this phenomenon and the first experimental results are shown, on a single-domain crystal of GaFeO{sub 3}. The measured antisymmetric Compton profile is very small (≃ 10{sup −5} of the symmetric part) and of the same order of magnitude as the statistical errors. Relativistic first-principles simulations of the antisymmetric Compton profile are presented and it is shown that, while the effect is indeed predicted by theory, and scales with the size of the valence spin–orbit interaction, its magnitude is significantly overestimated. The paper outlines some important constraints on the properties of the antisymmetric Compton profile arising from the underlying crystallographic symmetry of the sample.

  7. X-ray scattering evaluation of ultrastructural changes in human dental tissues with thermal treatment.

    Science.gov (United States)

    Sandholzer, Michael A; Sui, Tan; Korsunsky, Alexander M; Walmsley, Anthony Damien; Lumley, Philip J; Landini, Gabriel

    2014-05-01

    Micro- and ultrastructural analysis of burned skeletal remains is crucial for obtaining a reliable estimation of cremation temperature. Earlier studies mainly focused on heat-induced changes in bone tissue, while this study extends this research to human dental tissues using a novel quantitative analytical approach. Twelve tooth sections were burned at 400-900°C (30-min exposure, increments of 100°C). Subsequent combined small- and wide-angle X-ray scattering (SAXS/WAXS) experiments were performed at the Diamond Light Source synchrotron facility, where 28 scattering patterns were collected within each tooth section. In comparison with the control sample, an increase in mean crystal thickness was found in burned dentine (2.8-fold) and enamel (1.4-fold), however at a smaller rate than reported earlier for bone tissue (5-10.7-fold). The results provide a structural reference for traditional X-ray scattering methods and emphasize the need to investigate bone and dental tissues separately to obtain a reliable estimation of cremation temperature. © 2014 American Academy of Forensic Sciences.

  8. Investigation of nanoscale structures by small-angle X-ray scattering in a radiochromic dosimeter

    DEFF Research Database (Denmark)

    Skyt, Peter Sandegaard; Jensen, Grethe Vestergaard; Wahlstedt, Isak Hannes

    2014-01-01

    This study examines the nanoscale structures in a radiochromic dosimeter that was based on leuco-malachite-green dye and the surfactant sodium dodecyl sulfate (SDS) suspended in a gelatin matrix. Small-angle X-ray scattering was used to investigate the structures of a range of compositions...... of the dosimeter. When omitting gelatin, ellipsoidal micelles of SDS were formed with a core radius near 15 Å, an eccentricity of 1.6, and a head-group shell thickness near 7 Å. Gelatin significantly changed the micelles to a cylindrical shape with around three times lower core radius and four times larger shell...

  9. Nano-crystal growth in cordierite glass ceramics studied with X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bras, Wim; Clark, Simon M.; Greaves, G. N.; Kunz, Martin; van Beek, W.; Radmilovic, V.

    2009-01-16

    The development of monodisperse crystalline particles in cordierite glass doped with Cr3+ after a two-step heat treatment is elucidated by a combination of time-resolved small and wide angle x-ray scattering (SAXS/WAXS) experiments with electron microscopy. The effects of bulk and surface crystallization can clearly be distinguished, and the crystallization kinetics of the bulk phase is characterized. The internal pressure due to structural differences between the crystalline and amorphous phase is measured but the physical cause of this pressure can not unambiguously be attributed. The combined measurements comprise a nearly full characterization of the crystallization processes and the resulting sample morphology.

  10. Scattering of X-rays on the surface acoustic wave in the case of grazing geometry

    CERN Document Server

    Mkrtchyan, A R; Petrosian, A

    2000-01-01

    The scattering of X-rays on a crystal is considered in grazing geometry when a surface acoustic wave is excited normal to the diffraction vector. The intensity of wave field at finite distance from crystal to detector is obtained. It is shown that in the presence of surface acoustic wave the magnitude of the main peak of specular reflected diffracted wave intensity decreases and intensity of satellites increases. The main peak of specular reflected diffracted wave intensity is split up as the grazing observation angle increases.

  11. Study of Dislocation Loops in Ion-Irradiated Tungsten Using X-Ray Diffuse Scattering

    Science.gov (United States)

    Sun, Peihao; Heimann, Philip; Wang, Yongqiang; Frost, Mungo; Schonwalder, Christopher; Levitan, Abraham; Mo, Mianzhen; Chen, Zhijiang; Hastings, Jerome; Glenzer, Siegfried

    2017-10-01

    As the material of choice for the divertor wall in tokamak fusion reactors, tungsten is exposed to high levels of radiation. As a result, a large amount of defects form inside the crystal, leading to significant changes in its thermal-mechanical properties. Therefore, it is important to understand the types and sizes of radiation-induces defects. X-ray diffuse scattering around Bragg peaks has been developed as a technique to solve this problem. By applying this technique to ion-irradiated tungsten, we have obtained quantitative data on the size-distribution of dislocation loops under different radiation levels. This work is supported by DOE FES under FWP 100182.

  12. Wide-angle X-ray scattering study of heat-treated PEEK and PEEK composite

    Science.gov (United States)

    Cebe, Peggy; Lowry, Lynn; Chung, Shirley Y.; Yavrouian, Andre; Gupta, Amitava

    1987-01-01

    Samples of poly(etheretherketone) (PEEK) neat resin and APC-2 carbon fiber composite were subjected to various heat treatments, and the effect of quenching and annealing treatments was studied by wide-angle X-ray scattering. It is found that high-temperature treatments may introduce disorder into neat resin and composite PEEK when followed by rapid cooling. The disorder is metastable and can revert to ordered state when the material is heated above its glass transition temperature and then cooled slowly. The disorder may result from residual thermal stresses.

  13. Report on a round-robin study of diffuse X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Ohshima, K.; Harada, J.; Morinaga, M.; Georgopoulos, P.; Cohen, J.B.

    1986-06-01

    The diffuse scattering in a volume in reciprocal space from NbCsub(0.72) was measured on an absolute scale at two synchrotron sources (in the US and in Japan) and with a high-intensity rotating-anode source (in Japan). The shape and actual absolute intensities agreed to a few percent. Special problems associated with such measurements at a synchrotron are noted, especially with an insertion device. The high resolution possible at such sources reduces the need for an evacuated sample chamber. Detailed measurements can be completed in 1-2 d, making such studies much more accessible than is possible with sealed-tube X-ray generation.

  14. Phonon dynamics of liquid Si - inelastic X-ray scattering studies

    CERN Document Server

    Hosokawa, S; Demmel, F; Pilgrim, W C

    2003-01-01

    The dynamic structure factors S(Q,omega) of liquid Si were measured at 1480 deg. C using high-resolution inelastic X-ray scattering. The obtained spectra clearly demonstrate the existence of excitations of longitudinal propagating modes. The Q-omega relation of the inelastic modes shows a 15% positive deviation of the dispersion relation from hydrodynamics, analogous to liquid alkali metals. However, it is in contrast with liquid Ge, which possesses the electrical-, structural- and thermodynamic properties closely similar to those in l-Si.

  15. Switchable resonant x-ray Bragg scattering on a magnetic grating patterned by ion bombardment

    Science.gov (United States)

    Höink, V.; Sacher, M. D.; Schmalhorst, J.; Reiss, G.; Engel, D.; Weis, T.; Ehresmann, A.

    2006-09-01

    A local manipulation of the exchange bias coupling between antiferromagnetic and ferromagnetic layers by ion bombardment induced magnetic patterning enables a patterning of the magnetization direction of the ferromagnetic layer without considerable structural changes. We show that a magnetic line grating with alternating antiparallel orientations of the magnetization of the ferromagnetic layer acts as a magnetically switchable reflective grating for soft x-ray radiation. A common rotational direction of the magnetization at all boundaries between bombarded and not bombarded lines is shown by magnetic force microscopy measurements. Scattering at the edges of the bombarded lines might be responsible for the observed interference pattern.

  16. X-ray scattering combined with coordinate-based analyses for applications in natural and artificial photosynthesis.

    Science.gov (United States)

    Tiede, David M; Mardis, Kristy L; Zuo, Xiaobing

    2009-01-01

    Advances in X-ray light sources and detectors have created opportunities for advancing our understanding of structure and structural dynamics for supramolecular assemblies in solution by combining X-ray scattering measurement with coordinate-based modeling methods. In this review the foundations for X-ray scattering are discussed and illustrated with selected examples demonstrating the ability to correlate solution X-ray scattering measurements to molecular structure, conformation, and dynamics. These approaches are anticipated to have a broad range of applications in natural and artificial photosynthesis by offering possibilities for structure resolution for dynamic supramolecular assemblies in solution that can not be fully addressed with crystallographic techniques, and for resolving fundamental mechanisms for solar energy conversion by mapping out structure in light-excited reaction states. © Springer Science+Business Media B.V. 2009

  17. A model of primary and scattered photon fluence for mammographic x-ray image quantification

    Science.gov (United States)

    Tromans, Christopher E.; Cocker, Mary R.; Brady, Michael, Sir

    2012-10-01

    We present an efficient method to calculate the primary and scattered x-ray photon fluence component of a mammographic image. This can be used for a range of clinically important purposes, including estimation of breast density, personalized image display, and quantitative mammogram analysis. The method is based on models of: the x-ray tube; the digital detector; and a novel ray tracer which models the diverging beam emanating from the focal spot. The tube model includes consideration of the anode heel effect, and empirical corrections for wear and manufacturing tolerances. The detector model is empirical, being based on a family of transfer functions that cover the range of beam qualities and compressed breast thicknesses which are encountered clinically. The scatter estimation utilizes optimal information sampling and interpolation (to yield a clinical usable computation time) of scatter calculated using fundamental physics relations. A scatter kernel arising around each primary ray is calculated, and these are summed by superposition to form the scatter image. Beam quality, spatial position in the field (in particular that arising at the air-boundary due to the depletion of scatter contribution from the surroundings), and the possible presence of a grid, are considered, as is tissue composition using an iterative refinement procedure. We present numerous validation results that use a purpose designed tissue equivalent step wedge phantom. The average differences between actual acquisitions and modelled pixel intensities observed across the adipose to fibroglandular attenuation range vary between 5% and 7%, depending on beam quality and, for a single beam quality are 2.09% and 3.36% respectively with and without a grid.

  18. Recent investigations of silk fibers utilizing x-ray scattering and atomic force microscopy

    Science.gov (United States)

    Miller, Lance D.

    1998-12-01

    Silks from the mulberry silkworm, Bombyx mori, and the golden-orb spider, Nephila clavipes, are materials that possess respectable properties. Even pitted against the high performance fibers of Kevlar, polyethylene, and carbon, the advantages of some of nature's fibers are clear. The tensile strength of the golden-orb spider dragline is of the same order of magnitude as many synthetic fibers, yet the dragline's compressive strength as a percentage of its tensile strength is greater. The spider's ampullate glands, responsible for the manufacture of the dragline, also excel. The spider spins its fiber from a liquid crystalline solution that is water based versus the solutions at high temperatures containing volatile solvents that are required for current synthetic fibers. Understanding the morphology of silks will provide the basis for improved manufacturing and better performing synthetic fibers. The studies presented here have centered on the use of small-angle x-ray scattering, SAXS, to describe the large-scale morphology of silk fibers. We have determined minimum scattering dimensions on the order of 150-300 nm. A detailed analysis of the Porod scattering region has revealed correlation lengths of the same magnitude. Both of these dimensions are similar to with direct atomic force microscopy, AFM, measurements of nanofibers found in samples of abraded or peeled silk. The incorporation of discrete Fourier transform theory and AFM topographic information has yielded results in general agreement with measured SAXS patterns. This incorporation allows the materials scientist a way of visualizing the relationship between a material and its resulting scattering function. We have also found that x-ray scattering gives insight to new periodic distances of the morphology of golden-orb dragline. All of these studies yield a more complete view of the silk morphology and give a new method of model building from scattering experiments.

  19. Derivation of factors for estimating the scatter of diagnostic x-rays from walls and ceiling slabs.

    Science.gov (United States)

    Martin, C J; Sutton, D G; Magee, J; McVey, S; Williams, J R; Peet, D

    2012-12-01

    Computed tomography (CT) scanning rooms and interventional x-ray facilities with heavy workloads may require the installation of shielding to protect against radiation scattered from walls or ceiling slabs. This is particularly important for the protection of those operating x-ray equipment from within control cubicles who may be exposed to radiation scattered from the ceiling over the top of the protective barrier and round the side if a cubicle door is not included. Data available on the magnitude of this tertiary scatter from concrete slabs are limited. Moreover, there is no way in which tertiary scatter levels can be estimated easily for specific facilities. There is a need for a suitable method for quantification of tertiary scatter because of the increases in workloads of complex x-ray facilities. In this study diagnostic x-ray air kerma levels scattered from concrete and brick walls have been measured to verify scatter factors. The results have been used in a simulation of tertiary scatter for x-ray facilities involving summation of scatter contributions from elements across concrete ceiling slabs. The majority of the ceiling scatter air kerma to which staff behind a barrier will be exposed arises from the area between the patient/x-ray tube and the staff. The level depends primarily on the heights of the ceiling and protective barrier. A method has been developed to allow tertiary scatter levels to be calculated using a simple equation based on a standard arrangement for rooms with different ceiling and barrier heights. Coefficients have been derived for a CT facility and an interventional suite to predict tertiary scatter levels from the workload, so that consideration can be given to the protection options available.

  20. Estimating head and neck tissue dose from x-ray scatter to physicians performing x-ray guided cardiovascular procedures: a phantom study.

    Science.gov (United States)

    Fetterly, Kenneth A; Schueler, Beth A; Grams, Michael P; Sturchio, Glenn M

    2017-03-20

    Physicians performing x-ray guided interventional procedures have a keen interest in radiation safety. Radiation dose to tissues and organs of the head and neck are of particular interest because they are not routinely protected by wearable radiation safety devices. This study was conducted to facilitate estimation of radiation dose to tissues of the head and neck of interventional physicians based on the dose recorded by a personal dosimeter worn on the left collar. Scatter beam qualities maximum energy and HVL were measured for 40 scatter beams emitting from an anthropomorphic patient phantom. Variables of the scatter beams included scatter angle (35° and 90°), primary beam peak tube potential (60, 80, 100, and 120 kVp), and 5 Cu spectral filter thicknesses (0-0.9 mm). Four reference scatter beam qualities were selected to represent the range of scatter beams realized in a typical practice. A general radiographic x-ray tube was tuned to produce scatter-equivalent radiographic beams and used to simultaneously expose the head and neck of an anthropomorphic operator phantom and radiochromic film. The geometric relationship between the x-ray source of the scatter-equivalent beams and the operator phantom was set to mimic that between a patient and physician performing an invasive cardiovascular procedure. Dose to the exterior surface of the operator phantom was measured with both 3 × 3 cm2 pieces of film and personal dosimeters positioned at the location of the left collar. All films were scanned with a calibrated flatbed scanner, which converted the film's reflective density to dose. Films from the transverse planes of the operator phantom provided 2D maps of the dose distribution within the phantom. These dose maps were normalized by the dose at the left collar, providing 2D percent of left collar dose (LCD) maps. The percent LCD maps were overlain with bony anatomy CT images of the operator phantom and estimates of percent LCD to the left, right and whole

  1. Characterization of a large glycoprotein proteoglycan by size-exclusion chromatography combined with light and X-ray scattering methods.

    Science.gov (United States)

    Watanabe, Yasushi; Inoko, Yoji

    2013-08-16

    The molecular weight and chain conformation of a proteoglycan derived from shark cartilage in solution were characterized by size-exclusion chromatography combined with low-angle laser light scattering and small-angle X-ray scattering methods. The total molecular weight of the proteoglycan was 3.9±0.2 million and the molecular weight of the main component was about 2.0±0.2 million. The X-ray scattering data revealed that the main components of the proteoglycan are nearly equal to a chain with excluded volume and their persistence lengths range from 13.5 to 16.4nm. These results show that size-exclusion chromatography combined with low-angle laser light scattering and small-angle X-ray scattering measurements are complementarily useful for characterization of large biopolymers in solution. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. An apparatus for in situ x-ray scattering measurements during polymer injection molding.

    Science.gov (United States)

    Rendon, Stanley; Fang, Jun; Burghardt, Wesley R; Bubeck, Robert A

    2009-04-01

    We report a novel instrument for synchrotron-based in situ x-ray scattering measurements during injection molding processing. It allows direct, real-time monitoring of molecular-scale structural evolution in polymer materials undergoing a complex processing operation. The instrument is based on a laboratory-scale injection molding machine, and employs customized mold tools designed to allow x-ray access during mold filling and subsequent solidification, while providing sufficient robustness to withstand high injection pressures. The use of high energy, high flux synchrotron radiation, and a fast detector allows sufficiently rapid data acquisition to resolve time-dependent orientation dynamics in this transient process. Simultaneous monitoring of temperature and pressure signals allows transient scattering data to be referenced to various stages of the injection molding cycle. Representative data on a commercial liquid crystalline polymer, Vectra(R) B950, are presented to demonstrate the features of this apparatus; however, it may find application in a wide range of polymeric materials such as nanocomposites, semicrystalline polymers and fiber-reinforced thermoplastics.

  3. Ground state potential energy surfaces around selected atoms from resonant inelastic x-ray scattering.

    Science.gov (United States)

    Schreck, Simon; Pietzsch, Annette; Kennedy, Brian; Såthe, Conny; Miedema, Piter S; Techert, Simone; Strocov, Vladimir N; Schmitt, Thorsten; Hennies, Franz; Rubensson, Jan-Erik; Föhlisch, Alexander

    2016-01-29

    Thermally driven chemistry as well as materials' functionality are determined by the potential energy surface of a systems electronic ground state. This makes the potential energy surface a central and powerful concept in physics, chemistry and materials science. However, direct experimental access to the potential energy surface locally around atomic centers and to its long-range structure are lacking. Here we demonstrate how sub-natural linewidth resonant inelastic soft x-ray scattering at vibrational resolution is utilized to determine ground state potential energy surfaces locally and detect long-range changes of the potentials that are driven by local modifications. We show how the general concept is applicable not only to small isolated molecules such as O2 but also to strongly interacting systems such as the hydrogen bond network in liquid water. The weak perturbation to the potential energy surface through hydrogen bonding is observed as a trend towards softening of the ground state potential around the coordinating atom. The instrumental developments in high resolution resonant inelastic soft x-ray scattering are currently accelerating and will enable broad application of the presented approach. With this multidimensional potential energy surfaces that characterize collective phenomena such as (bio)molecular function or high-temperature superconductivity will become accessible in near future.

  4. Particle-scale structure in frozen colloidal suspensions from small-angle x-ray scattering

    KAUST Repository

    Spannuth, Melissa

    2011-02-01

    During directional solidification of the solvent in a colloidal suspension, the colloidal particles segregate from the growing solid, forming high-particle-density regions with structure on a hierarchy of length scales ranging from that of the particle-scale packing to the large-scale spacing between these regions. Previous work has concentrated mostly on the medium- to large-length scale structure, as it is the most accessible and thought to be more technologically relevant. However, the packing of the colloids at the particle scale is an important component not only in theoretical descriptions of the segregation process, but also to the utility of freeze-cast materials for new applications. Here we present the results of experiments in which we investigated this structure across a wide range of length scales using a combination of small-angle x-ray scattering and direct optical imaging. As expected, during freezing the particles were concentrated into regions between ice dendrites forming a microscopic pattern of high- and low-particle-density regions. X-ray scattering indicates that the particles in the high-density regions were so closely packed as to be touching. However, the arrangement of the particles does not conform to that predicted by standard interparticle pair potentials, suggesting that the particle packing induced by freezing differs from that formed during equilibrium densification processes. © 2011 American Physical Society.

  5. Quantitative spectromicroscopy from inelastically scattered photoelectrons in the hard X-ray range

    Energy Technology Data Exchange (ETDEWEB)

    Renault, O., E-mail: olivier.renault@cea.fr; Zborowski, C.; Risterucci, P. [Univ. Grenoble Alpes, F-38000 Grenoble, France and CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Wiemann, C.; Schneider, C. M. [Peter Grünberg Institute (PGI-6) and JARA-FIT, Research Center Jülich, D-52425 Jülich (Germany); Grenet, G. [Institut des Nanotechnologies de Lyon, Ecole Centrale, 69134 Ecully Cedex (France); Tougaard, S. [Department of Physics, Chemistry and Pharmacy, University of Southern Denmark, DK-5230 Odense M (Denmark)

    2016-07-04

    We demonstrate quantitative, highly bulk-sensitive x-ray photoelectron emission microscopy by analysis of inelastically scattered photoelectrons in the hard X-ray range, enabling elemental depth distribution analysis in deeply buried layers. We show results on patterned structures used in electrical testing of high electron mobility power transistor devices with an epitaxial Al{sub 0.25}Ga{sub 0.75}N channel and a Ti/Al metal contact. From the image series taken over an energy range of up to 120 eV in the Ti 1s loss feature region and over a typical 100 μm field of view, one can accurately retrieve, using background analysis together with an optimized scattering cross-section, the Ti depth distribution from 14 nm up to 25 nm below the surface. The method paves the way to multi-elemental, bulk-sensitive 3D imaging and investigation of phenomena at deeply buried interfaces and microscopic scales by photoemission.

  6. Small-angle x-ray scattering study on the structure of microcrystalline and nanofibrillated cellulose

    Science.gov (United States)

    Leppänen, Kirsi; Pirkkalainen, Kari; Penttilä, Paavo; Sievänen, Jenni; Kotelnikova, Nina; Serimaa, Ritva

    2010-10-01

    The effects of different solvents on the structure of microcrystalline and nanofibrillated cellulose (MCC, NFC) were studied using small-angle x-ray scattering (SAXS). MCC was immersed in water, ethanol, and acetone, and NFC was immersed only in water and ethanol, but studied also in the form of foam-like water-NFC-gel in wet, air-dried and re-wet states. The solvent affected the average chord length, which reveals the typical length scale of the structure of the sample: 2.4 ± 0.1 nm was obtained for MCC-water, 2.5 ± 0.1 nm for re-wet NFC-gel, 1.6 ± 0.1 nm for MCC-ethanol, 1.2 ± 0.1 nm for NFC-ethanol, and 1.3 ± 0.1 nm for MCC-acetone. The specific surface of cellulose increased strongly when MCC and NFC were immersed in the solvents compared to dry cellulose. The specific surface of cellulose was determined to be larger for NFC-water than MCC-water, and slightly larger for dry NFC powder than for dry MCC, which can be explained by the fact that the width of cellulose crystallites perpendicular to the cellulose chain direction was slightly larger in MCC than in NFC on the basis of wide-angle x-ray scattering results.

  7. Application of ultra-small-angle X-ray scattering / X-ray photon correlation spectroscopy to relate equilibrium or non-equilibrium dynamics to microstructure

    Science.gov (United States)

    Allen, Andrew; Zhang, Fan; Levine, Lyle; Ilavsky, Jan

    2013-03-01

    Ultra-small-angle X-ray scattering (USAXS) can probe microstructures over the nanometer-to-micrometer scale range. Through use of a small instrument entrance slit, X-ray photon correlation spectroscopy (XPCS) exploits the partial coherence of an X-ray synchrotron undulator beam to provide unprecedented sensitivity to the dynamics of microstructural change. In USAXS/XPCS studies, the dynamics of local structures in a scale range of 100 nm to 1000 nm can be related to an overall hierarchical microstructure extending from 1 nm to more than 1000 nm. Using a point-detection scintillator mode, the equilibrium dynamics at ambient temperature of small particles (which move more slowly than nanoparticles) in aqueous suspension have been quantified directly for the first time. Using a USAXS-XPCS scanning mode for non-equilibrium dynamics incipient processes within dental composites have been elucidated, prior to effects becoming detectable using any other technique. Use of the Advanced Photon Source, an Office of Science User Facility operated for the United States Department of Energy (U.S. DOE) Office of Science by Argonne National Laboratory, was supported by the U.S. DOE under Contract No. DE-AC02-06CH11357.

  8. Novel opportunities for sub-meV inelastic X-ray scattering at high-repetition rate self-seeded X-ray free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Chubar, Oleg [Brookhaven National Laboratory, Upton, NY (United States). National Synchrotron Light Source II; Geloni, Gianluca; Madsen, Anders [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni; Serkez, Svitozar [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Shvyd' ko, Yuri [Argonne National Laboratory, IL (United States). Advanced Photon Source; Sutter, John [Diamond Light Source Ltd., Didcot (United Kingdom)

    2015-08-15

    Inelastic X-ray scattering (IXS) is an important tool for studies of equilibrium dynamics in condensed matter. A new spectrometer recently proposed for ultra-high-resolution IXS (UHRIX) has achieved 0.6 meV and 0.25 nm{sup -1} spectral and momentum transfer resolutions, respectively. However, further improvements down to 0.1 meV and 0.02 nm{sup -1} are required to close the gap in energy-momentum space between high and low frequency probes. We show that this goal can be achieved by further optimizing the X-ray optics and by increasing the spectral flux of the incident X-ray pulses. UHRIX performs best at energies from 5 to 10 keV, where a combination of self-seeding and undulator tapering at the SASE-2 beamline of the European XFEL promises up to a hundred-fold increase in average spectral flux compared with nominal SASE pulses at saturation, or three orders of magnitude more than possible with storage-ring based radiation sources. Wave-optics propagation shows that about 7 x 10{sup 12} ph/s in a 90-μeV bandwidth can be achieved on the sample. This will provide unique new possibilities for dynamics studies by IXS.

  9. Dissipative quantum hydrodynamics model of x-ray Thomson scattering in dense plasmas

    Science.gov (United States)

    Diaw, Abdourahmane; Murillo, Michael

    2017-10-01

    X-ray Thomson scattering (XRTS) provides detailed diagnostic information about dense plasma experiments. The inferences made rely on an accurate model for the form factor, which is typically expressed in terms of a well-known response function. Here, we develop an alternate approach based on quantum hydrodynamics using a viscous form of dynamical density functional theory. This approach is shown to include the equation of state self-consistently, including sum rules, as well as irreversibility arising from collisions. This framework is used to generate a model for the scattering spectrum, and it offers an avenue for measuring hydrodynamic properties, such as transport coefficients, using XRTS. This work was supported by the Air Force Office of Scientific Research (Grant No. FA9550-12-1-0344).

  10. Investigation of X-Ray Harmonics in the Polarized Nonlinear Inverse Compton Scattering Experiment at UCLA

    CERN Document Server

    Doyuran, Adnan; Joshi, Chandrashekhar; Lim, Jae; Rosenzweig, James E; Tochitsky, Sergei Ya; Travish, Gil; Williams, Oliver

    2005-01-01

    An Inverse Compton Scattering (ICS) experiment investigating the polarized harmonic production in the nonlinear regime has begun which will utilize the existing terawatt CO2 laser system and 15 MeV photoinjector in the Neptune Laboratory at UCLA. A major motivation for a source of high brightness polarized x-rays is the production of polarized positrons for use in future linear collider experiments. Analytical calculations have been performed to predict the angular and frequency spectrums for various polarizations and different scattering angles. Currently, the experiment is running and we report the set-up and initial results. The advantages and limitations of using a high laser vector potential, ao, in an ICS-based polarized positron source are expected to be revealed with further measurement of the harmonic spectrum and angular characteristics.

  11. Spin effects probed by Rayleigh X-ray scattering off hydrogenic ions

    CERN Document Server

    Safari, Laleh; Amaro, Pedro; Fratini, Filippo

    2014-01-01

    We study the polarization characteristics of x-ray photons scattered by hydrogenic atoms, based on the Dirac equation and second-order perturbation theory. The relativistic states used in calculations are obtained using the finite basis set method and expressed in terms of B-splines and B-polynomials. We derive general analytical expressions for the polarization-dependent total cross sections, which are applicable to any atom and ion, and evaluate them separately for linear and circular polarization of photons. In particular, detailed calculations are performed for the integrated Stokes parameters of the scattered light for hydrogen as well as hydrogenlike neon and argon. Analyzing such integrated Stokes parameters, special attention is given to the electron-photon spin-spin interaction, which mostly stems from the magnetic-dipole contribution of the electron-photon interaction. Subsequently, we find an energy window for the selected targets in which such spin-spin interactions can be probed.

  12. Investigation of X-Ray Thomson Scattering Using A Statistical Approach

    Science.gov (United States)

    Johnson, Laura

    2014-10-01

    We present a statistical method of computing x-ray Thomson scattering signals. This model uses average atom wave functions for both bound and continuum electrons, which are computed in a spherically symmetric, self-consistent potential. The wave functions are used to obtain electron distributions for a statistical approach to computing the scattering signals. We compare the differences between using distorted-wave continuum electrons and free-wave electrons in both the statistical approach and the impulse approximation. The results are compared to various experiments including experimental data taken at Cornell's Laboratory of Plasma Studies. Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL85000.

  13. Resonant Soft X-ray Scattering Studies of Multiferroic YMn2O5

    Energy Technology Data Exchange (ETDEWEB)

    Partzsch, S.; Wilkins, S.B.; Schierle, E.; Soltwisch, V.; Hill, J.P.; Weschke, E.; Souptel, D.; Buchner, B.; Geck, J.

    2011-06-17

    We performed soft x-ray resonant scattering at the MnL{sub 2,3}- and OK edges of YMn{sub 2}O{sub 5}. While the resonant intensity at the MnL{sub 2,3} edges represent the magnetic order parameter, the resonant scattering at the OK edge is found to be directly related to the macroscopic ferroelectric polarization. The latter observation reveals the important role of the spin-dependent Mn-O hybridization for the multiferroicity of YMn{sub 2}O{sub 5}. We present details about how to obtain correct energy dependent lineshapes and discuss the origin of the resonant intensity at the OK edge.

  14. Direct Observation of Insulin Association Dynamics with Time-Resolved X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Rimmerman, Dolev [Department; Leshchev, Denis [Department; Hsu, Darren J. [Department; Hong, Jiyun [Department; Kosheleva, Irina [Center; Chen, Lin X. [Department; Chemical

    2017-09-05

    Biological functions frequently require protein-protein interactions that involve secondary and tertiary structural perturbation. Here we study protein-protein dissociation and reassociation dynamics in insulin, a model system for protein oligomerization. Insulin dimer dissociation into monomers was induced by a nanosecond temperature-jump (T-jump) of ~8 °C in aqueous solution, and the resulting protein and solvent dynamics were tracked by time-resolved X-ray solution scattering (TRXSS) on time scales of 10 ns to 100 ms. The protein scattering signals revealed the formation of five distinguishable transient species during the association process that deviate from simple two state kinetics. Our results show that the combination of T-jump pump coupled to TRXSS probe allows for direct tracking of structural dynamics in nonphotoactive proteins.

  15. Solution X-ray scattering (S/WAXS) and structure formation in protein dynamics

    CERN Document Server

    Nasedkin, Alexandr; Niemi, Antti J; Peng, Xubiao

    2016-01-01

    We propose to develop mean field theory in combination with Glauber algorithm, to model and interpret protein dynamics and structure formation in small to wide angle x-ray scattering (S/WAXS) experiments. We develop the methodology by analysing the Engrailed homeodomain protein as an example. We demonstrate how to interpret S/WAXS data with a good precision and over an extended temperature range. We explain experimentally observed phenomena in terms of protein phase structure, and we make predictions for future experiments how the scattering data behaves at different ambient temperature values. We conclude that a combination of mean field theory with Glauber algorithm has the potential to develop into a highly accurate, computationally effective and predictive tool for analysing S/WAXS data. Finally, we compare our results with those obtained previously in an all-atom molecular dynamics simulation.

  16. Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements.

    Science.gov (United States)

    Sedlak, Steffen M; Bruetzel, Linda K; Lipfert, Jan

    2017-04-01

    A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ2(q) = [I(q) + const.]/(kq), where I(q) is the scattering intensity as a function of the momentum transfer q; k and const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurement errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.

  17. Structural Characterization of Polymers of Intrinsic Microporosity Using X-ray Scattering Methods

    Science.gov (United States)

    McDermott, Amanda; Chaukura, Nhamo; Mason, Christopher; Budd, Peter; Msayib, Kadum; Carta, Mariolino; Ghanem, Bader; McKeown, Neil; Runt, James

    2010-03-01

    Polymers of intrinsic microporosity (PIMs) are a novel class of materials with a large inner surface area and large free volume, which make them suitable for hydrogen adsorption. In addition, they exhibit a combination of high permeability and high selectivity useful for filtration applications. A series of polymers with high glass transition temperatures based on PIM-1, a polybenzodioxane with a ladder-type structure combining stiff segments with sites of contortion, as well as a series of triptycene-based network PIMs, are characterized via small-angle and wide-angle X-ray scattering. Scattering features, including multiple amorphous halos and a characteristic power-law slope, are related to polymer chemistry, hydrogen adsorption performance, and gas permeation parameters.

  18. Guest–Host Interactions Investigated by Time-Resolved X-ray Spectroscopies and Scattering at MHz Rates

    DEFF Research Database (Denmark)

    Haldrup, Martin Kristoffer; Vanko, G.; Gawelda, W.

    2012-01-01

    We have studied the photoinduced low spin (LS) to high spin (HS) conversion of [Fe(bipy)3]2+ in aqueous solution. In a laser pump/X-ray probe synchrotron setup permitting simultaneous, time-resolved X-ray diffuse scattering (XDS) and X-ray spectroscopic measurements at a 3.26 MHz repetition rate,...... of the caging solvent, in particular, a decrease in the number of water molecules in the first solvation shell is inferred, as predicted by recent theoretical work....

  19. Exact and explicit expression of the atomic pair distribution function as obtained from X-ray total scattering experiments

    OpenAIRE

    Masson, Olivier; Thomas, Philippe

    2013-01-01

    International audience; The atomic pair distribution function (PDF) as obtained from X-ray or neutron total scattering experiments has proved to be powerful in obtaining valuable structural information for many complex functional materials, be they amorphous or crystalline. In the case of measurements made with X-rays and for samples containing more than one kind of atom, the usefulness of the PDF is, however, somewhat hampered because of the lack of an exact and simple expression relating it...

  20. In situ coherent x-ray scattering and STM studies of hexagonally reconstructed Au(001) in Electrolytes

    Science.gov (United States)

    Pierce, Michael S.; Komanicky, Vladimir; Barbour, Andi; Hennessy, Daniel; Su, Jun-Dar; Sandy, Alec; You, Hoydoo

    2011-03-01

    We have studied the dynamics of Au(001) and Au(111) surfaces in situ in 0.1 M HClO4 electrolyte solution using coherent x-ray scattering experiments and STM microscopy. Our coherent x-ray scattering experiments measure a correlation time for the surface as a function of applied potentials. Coherent x-ray scattering differs from the ordinary x-ray diffraction in sensitivity to the structural and temporal details. The correlation times were obtained from measurements conducted while the surface is in equilibrium and the ordinary surface scattering intensity is constant. The correlation time changes from high 103 seconds to low 102 seconds. The correlation times of reconstructed surfaces at low potential are at least an order of magnitude smaller than those measured at the reconstructed surfaces in vacuum. The correlation times also change dramatically in response to the applied potential. These experiments also represent the first successful application of coherent x-ray scattering to the study of electrochemical interfaces in situ. Work at ANL is supported by DOE-BES and work at SU by VEGA.

  1. How many x-ray photons can be scattered from a SPECT/CT room to an adjacent gamma camera?

    Science.gov (United States)

    Cao, Zongjian

    2009-02-01

    The upper limit of the amount of x-rays that are scattered from a SPECT/CT room and are acquired by an adjacent gamma camera is estimated using physical principles and approximations. Methods: We first estimated the amount of xrays scattered from the patient to the ceiling of the SPECT/CT room, then the amount scattered from the ceiling through the gap between the ceiling and the top of lead walls to reach outside of the room, and finally the amount acquired by an adjacent gamma camera into the Tl-201 data. Results: The counts of scattered x-ray photons acquired in the Tl-201 energy window can reach 0.12% of the CT primary counts when the standard 2.13 m high lead walls are used for the SPECT/CT room. Due to the high CT counts, contamination to the Tl-201 data cannot be ignored. It is not effective to reduce the contamination by increase the lead height or change the floor plan because the scattered x-rays reduce moderately with increasing lead height or different floor plans. When the lead height increases from 2.13 m to 2.74 m, for example, the amount of scattered x-rays only decreases by 20%. With the same 2.13 m lead height, there is little difference in the amount of scattered x-rays for three different floor plans. Conclusions: The standard lead walls for a SPECT/CT room cannot prevent scattered x-rays from severe contamination to the Tl-201 data acquired by an adjacent gamma camera. Since dramatic increase of lead height is costly and often prohibitive due to the heavy load, we recommend that Tl-201 studies be stopped when an adjacent CT scanner is in operation.

  2. K-edge resonant x-ray magnetic scattering from a transition-metal oxide: NiO

    DEFF Research Database (Denmark)

    Hill, J.P.; Kao, C.C.; McMorrow, D.F.

    1997-01-01

    We report the observation of resonant x-ray magnetic scattering in the vicinity of the Ni K edge in the antiferromagnet NiO. An approximately twofold increase in the scattering is observed as the incident photon energy is tuned through a pre-edge feature in the absorption spectrum, associated wit...

  3. Non-invasive classification of breast microcalcifications using x-ray coherent scatter computed tomography

    Science.gov (United States)

    Ghammraoui, Bahaa; Popescu, Lucretiu M.

    2017-02-01

    We investigate the use of energy dispersive x-ray coherent scatter computed tomography (ED-CSCT) as a non-invasive diagnostic method to differentiate between type I and type II breast calcifications. This approach is sensitive to the differences of composition and internal crystal structure of different types of microcalcifications. The study is carried out by simulating a CSCT system with a scanning pencil beam, considering a polychromatic x-ray source and an energy-resolving photon counting detector. In a first step, the multidimensional angle and energy distributed CSCT data is reduced to the projection-space distributions of only a few components, corresponding to the expected target composition: adipose, glandular tissue, weddellite (calcium oxalate) for type I calcifications, and hydroxyapatite for type II calcifications. The maximum-likelihood estimation of scatter components algorithm used, operating in the projection space, takes into account the polychromatic source, the detector response function and the energy dependent attenuation. In the second step, component images are reconstructed from the corresponding estimated component projections using filtered backprojection. In a preliminary step the coherent scatter differential cross sections for hydroxyapatite and weddellite minerals were determined experimentally. The classification of type I or II calcifications is done using the relative contrasts of their components as the criterion. Simulation tests were carried out for different doses and energy resolutions for multiple realizations. The results were analyzed using relative/receiver operating characteristic methodology and show good discrimination ability at medium and higher doses. The noninvasive CSCT technique shows potential to further improve the breast diagnostic accuracy and reduce the number of breast biopsies.

  4. Three-dimensional time and frequency-domain theory of femtosecond x-ray pulse generation through Thomson scattering

    Directory of Open Access Journals (Sweden)

    Winthrop J. Brown

    2004-06-01

    Full Text Available The generation of high intensity, ultrashort x-ray pulses enables exciting new experimental capabilities, such as femtosecond pump-probe experiments used to temporally resolve material structural dynamics on atomic time scales. Thomson backscattering of a high intensity laser pulse with a bright relativistic electron bunch is a promising method for producing such high-brightness x-ray pulses in the 10–100 keV range within a compact facility. While a variety of methods for producing subpicosecond x-ray bursts by Thomson scattering exist, including compression of the electron bunch to subpicosecond bunch lengths and/or colliding a subpicosecond laser pulse in a side-on geometry to minimize the interaction time, a promising alternative approach to achieving this goal while maintaining ultrahigh brightness is the production of a time-correlated (or chirped x-ray pulse in conjunction with pulse slicing or compression. We present the results of a complete analysis of this process using a recently developed 3D time and frequency-domain code for analyzing the spatial, temporal, and spectral properties an x-ray beam produced by relativistic Thomson scattering. Based on the relativistic differential cross section, this code has the capability to calculate time and space dependent spectra of the x-ray photons produced from linear Thomson scattering for both bandwidth-limited and chirped incident laser pulses. Spectral broadening of the scattered x-ray pulse resulting from the incident laser bandwidth, laser focus, and the transverse and longitudinal phase space of the electron beam were examined. Simulations of chirped x-ray pulse production using both a chirped electron beam and a chirped laser pulse are presented. Required electron beam and laser parameters are summarized by investigating the effects of beam emittance, energy spread, and laser bandwidth on the scattered x-ray spectrum. It is shown that sufficient temporal correlation in the scattered

  5. High-resolution resonant inelastic X-ray scattering with soft X-rays at the ADRESS beamline of the Swiss light source: Instrumental developments and scientific highlights

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Thorsten, E-mail: thorsten.schmitt@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Strocov, Vladimir N.; Zhou, Ke-Jin; Schlappa, Justine; Monney, Claude; Flechsig, Uwe; Patthey, Luc [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2013-06-15

    Highlights: ► We have optimized the grating optics for VLS type RIXS spectrometers. ► Cu L{sub 3} RIXS can efficiently probe magnetic fluctuations in quasi-one dimensional cuprates. ► RIXS is sensitive to spin–orbital separation in one-dimensional cuprates. ► RIXS is capable to give information on interface states in oxide heterostructures. ► Mapping of electron–hole pair excitations with RIXS probes the unoccupied band structure. -- Abstract: The experimental development of the resonant inelastic X-ray scattering (RIXS) technique in the soft X-ray energy range has been tremendous during the last years. The ADRESS beamline at the Paul Scherrer Institut in Switzerland and its RIXS spectrometer SAXES has boosted the scientific capabilities with soft X-ray RIXS. Increased resolving power above 10,000 and the possibility to rotate the spectrometer to different scattering geometries allows analyzing the collective behavior of charge, orbital and spin excitations by assessing their momentum dependence. Focus of most projects at this facility lies in the investigation of low- and medium-energy excitations in correlated electron materials. In addition ADRESS has also been used for RIXS investigations on molecules in the liquid and gaseous phase. This review reports on the recent extension of the optics of the SAXES RIXS spectrometer with an additional grating optimized for the spectral range from ca. 400 to 700 eV. Furthermore, the scientific opportunities emerging from ADRESS are highlighted in RIXS studies on quasi one-dimensional cuprates, oxide heterostructures and a weakly correlated broad band material.

  6. Modeling and design of radiative hydrodynamic experiments with X-ray Thomson Scattering measurements on NIF

    Science.gov (United States)

    Ma, K. H.; Lefevre, H. J.; Belancourt, P. X.; MacDonald, M. J.; Doeppner, T.; Keiter, P. A.; Kuranz, C. C.; Johnsen, E.

    2017-10-01

    Recent experiments at the National Ignition Facility studied the effect of radiation on shock-driven hydrodynamic instability growth. X-ray radiography images from these experiments indicate that perturbation growth is lower in highly radiative shocks compared to shocks with negligible radiation flux. The reduction in instability growth is attributed to ablation from higher temperatures in the foam for highly radiative shocks. The proposed design implements the X-ray Thomson Scattering (XRTS) technique in the radiative shock tube platform to measure electron temperatures and densities in the shocked foam. We model these experiments with CRASH, an Eulerian radiation hydrodynamics code with block-adaptive mesh refinement, multi-group radiation transport and electron heat conduction. Simulations are presented with SiO2 and carbon foams for both the high temperature, radiative shock and the low-temperature, hydrodynamic shock cases. Calculations from CRASH give estimations for shock speed, electron temperature, effective ionization, and other quantities necessary for designing the XRTS diagnostic measurement. This work is funded by the LLNL under subcontract B614207, and was performed under the auspices of the U.S. DOE by LLNL under Contract No. DE-AC52-07NA27344.

  7. Improving small-angle X-ray scattering data for structural analyses of the RNA world.

    Science.gov (United States)

    Rambo, Robert P; Tainer, John A

    2010-03-01

    Defining the shape, conformation, or assembly state of an RNA in solution often requires multiple investigative tools ranging from nucleotide analog interference mapping to X-ray crystallography. A key addition to this toolbox is small-angle X-ray scattering (SAXS). SAXS provides direct structural information regarding the size, shape, and flexibility of the particle in solution and has proven powerful for analyses of RNA structures with minimal requirements for sample concentration and volumes. In principle, SAXS can provide reliable data on small and large RNA molecules. In practice, SAXS investigations of RNA samples can show inconsistencies that suggest limitations in the SAXS experimental analyses or problems with the samples. Here, we show through investigations on the SAM-I riboswitch, the Group I intron P4-P6 domain, 30S ribosomal subunit from Sulfolobus solfataricus (30S), brome mosaic virus tRNA-like structure (BMV TLS), Thermotoga maritima asd lysine riboswitch, the recombinant tRNA(val), and yeast tRNA(phe) that many problems with SAXS experiments on RNA samples derive from heterogeneity of the folded RNA. Furthermore, we propose and test a general approach to reducing these sample limitations for accurate SAXS analyses of RNA. Together our method and results show that SAXS with synchrotron radiation has great potential to provide accurate RNA shapes, conformations, and assembly states in solution that inform RNA biological functions in fundamental ways.

  8. A Microbeam Small-Angle X-ray Scattering Study on Enamel Crystallites in Subsurface Lesion

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, N; Ohta, N; Matsuo, T [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan); Tanaka, T; Terada, Y; Kamasaka, H; Kometani, T, E-mail: yagi@spring8.or.j [Ezaki Glico Co. Ltd., 4-6-5 Utajima, Nishiyodogawa-ku, Osaka 555-8502 (Japan)

    2010-10-01

    The early caries lesion in bovine tooth enamel was studied by two different X-ray diffraction systems at the SPring-8 third generation synchrotron radiation facility. Both allowed us simultaneous measurement of the small and large angle regions. The beam size was 6{mu}m at BL40XU and 50{mu}m at BL45XU. The small-angle scattering from voids in the hydroxyapatite crystallites and the wide-angle diffraction from the hydroxyapatite crystals were observed simultaneously. At BL40XU an X-ray image intensifier was used for the small-angle and a CMOS flatpanel detector for the large-angle region. At BL45XU, a large-area CCD detector was used to cover both regions. A linear microbeam scan at BL40XU showed a detailed distribution of voids and crystals and made it possible to examine the structural details in the lesion. The two-dimensional scan at BL45XU showed distribution of voids and crystals in a wider region in the enamel. The simultaneous small- and wide-angle measurement with a microbeam is a powerful tool to elucidate the mechanisms of demineralization and remineralization in the early caries lesion.

  9. Synchrotron X-ray Scattering Studies of Poly(lactide) Electrospun Fibers Containing Carbon Nanotubes

    Science.gov (United States)

    Zhu, Yazhe; Cebe, Peggy

    2014-03-01

    Carbon nanotubes(CNTs) often serve as an effective nucleating agent that facilitates the crystallization of semicrystalline polymers. Here we study the influence of CNTs on thermal and structural properties of Poly-lactide (PLA), which is well-known as a biodegradable and biocompatible thermoplastic polymer. The effect of CNTs on the crystallization and melting behavior of electrospun fibers of poly (L-lactide) (PLLA, with 100% L-isomer) and poly (D-lactide) (PDLA, containing 4% D-isomer) was systemically studied by scanning electron microscopy (SEM), differential scanning calorimetry (DSC), Fourier transform spectroscopy(FT-IR) and real time synchrotron wide-angle X-ray scattering (WAXS) . Multi-walled CNTs were co-electrospun with the poly(lactides) in weight ratios ranging from 0.1 to 4.0 wt% MW-CNT. PLA/carbon nanotubes composite electrospun fibers were successfully produced by appropriate choice of processing conditions and solution concentration. The morphologies of neat and CNT-filled electrospun nanofibers were observed by scanning electron microscopy. WAXS and DSC results show that lower content of CNTs contributes to higher speed of crystallization. However the results also showed that at the highest concentration of CNTs the ultimate crystallinity was reduced. FTIR and X-ray results show that PLA fibers have different crystal forms at high and low crystallization temperature. DSC results also show that D-lactide has reduced crystallinity compared to L-lactide.

  10. Morphological and structural characterization of PHBV/organoclay nanocomposites by small angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Carli, Larissa N., E-mail: lncarli@ucs.br [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, Av. Bento Goncalves, 9500, Porto Alegre, 91501-970, RS (Brazil); Centro de Ciencias Exatas e Tecnologia, Universidade de Caxias do Sul, Rua Francisco Getulio Vargas, 1130, Caxias do Sul, 95070-560, RS (Brazil); Bianchi, Otavio, E-mail: obianchi@ucs.br [Centro de Ciencias Exatas e Tecnologia, Universidade de Caxias do Sul, Rua Francisco Getulio Vargas, 1130, Caxias do Sul, 95070-560, RS (Brazil); Machado, Giovanna, E-mail: giovannamachado@uol.com.br [Centro de Tecnologias Estrategicas do Nordeste, Av. Prof. Luiz Freire, 01, Cidade Universitaria, Recife, 50740-540, PE (Brazil); Programa de Pos-Graduacao de Materiais, Universidade Federal de Pernambuco, Av. Prof. Moraes Rego, 1235, Recife, 50670-901, PE (Brazil); Crespo, Janaina S., E-mail: jscrespo@ucs.br [Centro de Ciencias Exatas e Tecnologia, Universidade de Caxias do Sul, Rua Francisco Getulio Vargas, 1130, Caxias do Sul, 95070-560, RS (Brazil); Mauler, Raquel S., E-mail: raquel.mauler@ufrgs.br [Instituto de Quimica, Universidade Federal do Rio Grande do Sul, Av. Bento Goncalves, 9500, Porto Alegre, 91501-970, RS (Brazil)

    2013-03-01

    In this work, the morphological and structural behaviors of poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) nanocomposites were investigated using small angle X-ray scattering (SAXS), wide angle X-ray diffraction (WAXD) and transmission electron microscopy (TEM). The nanocomposites with 1, 3 and 5 wt.% of organically modified montmorillonite Cloisite Registered-Sign 30B (OMMT) were prepared by melt processing in a twin screw extruder using two different processing conditions (low and high shear intensity). The lamellar long period of the polymer was lower for the nanocomposites, with high polydispersity values. However, the crystalline thickness increased with the clay content and was independent of the processing conditions. This behavior resulted in a high linear crystallinity of the nanocomposites with 3 and 5 wt.% OMMT. The disruption factor ({beta}) was in agreement with the WAXD and TEM findings, indicating a good dispersion of the nanoparticles in the PHBV matrix with 3 wt.% of OMMT during the high shear intensity of melt processing. Highlights: Black-Right-Pointing-Pointer SAXS was used for morphological and crystalline studies of PHBV/OMMT nanocomposites. Black-Right-Pointing-Pointer The crystalline structure was influenced by the presence of clay. Black-Right-Pointing-Pointer The degree of clay dispersion in a polymer matrix was quantified. Black-Right-Pointing-Pointer The morphology comprised exfoliated particles, nanoscale and microscale clusters. Black-Right-Pointing-Pointer The results obtained by SAXS agreed well with TEM and WAXD results.

  11. Spatiotemporal Imaging of Chemical Reactions: Making Molecular Movies with Femtosecond X-Ray Scattering

    Science.gov (United States)

    Budarz, J. M.; Minitti, M. P.; Kirrander, A.; Hastings, J. B.; Weber, P. M.

    2015-03-01

    The study of ultrafast reaction dynamics of molecular systems has benefited from the rapid development of spectroscopic and imaging techniques that follow their temporal evolution on a sub-picosecond time scale. More complete understanding of molecular behavior, however, is expected to arise from a full observation of electronic and nuclear motions during reactions. Our recent experiments at the Linac Coherent Light Source (LCLS) have allowed us to develop and implement a method wherein the ultrafast reaction dynamics of molecules in dilute gases (4 Torr) are captured by time-resolved X-ray scattering. Using a pump-probe scheme with 267 nm excitation laser and 8.3 keV X-ray probe pulses, we performed a series of measurements on the interatomic positions at variable delay times to produce a `molecular movie.' In our experiments, 1,3-cyclohexadiene (CHD) is prepared on an excited state surface, causing the molecule to accelerate down several potential energy surfaces coupled by conical intersections, to open into 1,3,5-hexatriene within 80 fs. The resulting `movie' has been supplemented with molecular trajectory calculations to separate the multiple pathways the excited molecule takes toward the open ring. In this talk, the experimental methods and designs that made these experiments possible will be presented together with the first results describing the photochemical reaction dynamics of CHD.

  12. Characterizing morphology in organic systems with resonant soft X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, Joshua H.; Hunt, Adrian; Ade, Harald, E-mail: harald_ade@ncsu.edu

    2015-04-15

    Highlights: • A brief history of the development of R-SoXS for studying soft matter systems. • A theoretical background and an overview of analysis methodology. • Applications to block copolymers, organic electronics, and biological systems. • A discussion of emerging applications and an outlook on the future of R-SoXS. - Abstract: Resonant soft X-ray scattering (R-SoXS) has proven to be a highly useful technique for studying the morphology of soft matter thin films due to the large intrinsic contrast between organic materials and the anisotropic nature of the resonant electronic state transitions from which the contrast originates. This allows R-SoXS users to measure spatial composition correlations from crystalline and amorphous phases in heterogeneous organic samples, infer relative domain purity, and determine average local molecular ordering correlations. R-SoXS has been used to study the morphology of organic photovoltaics, organic thin film transistors, biological systems, and block copolymer engineering applications. The mesoscopic morphological information compliments molecular packing information determined with hard X-rays, so that complex structure–property relationships can be elucidated over a large range of length scales. Extensions of R-SoXS have also emerged that make use of more advanced sample setups or different experimental geometries than normal transmission, such as θ–2θ reflectivity or grazing incidence.

  13. Analysis of low-angle x-ray scattering peaks from lyophilized biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Desouky, Omar S. [Radiation Physics Department, National Center for Radiation Research and Technology, A.E.A., Cairo (Egypt)]. E-mail: omardesouky@yahoo.com; Elshemey, Wael M. [Biophysics Department, Faculty of Science, Cairo University (Egypt); Selim, Nabila S.; Ashour, Ahmed H. [Radiation Physics Department, National Center for Radiation Research and Technology, A.E.A., Cairo (Egypt)

    2001-08-01

    Low-angle x-ray scattering (LAXS) from lyophilized blood and its constituents is characterized by the presence of two peaks in the forward direction of scattering. These peaks are found to be sensitive to the variations in the molecular structure of a given sample. The present work aims to explore the nature of LAXS from a variety of lyophilized biological samples. It also aims to investigate the possibility that a certain biological macromolecule is responsible of the production of LAXS peaks. This is carried out through measurements of LAXS from complex biological samples and their basic constituents. Among the measured samples are haemoglobin (Hb), globin, haem, packed red blood cells, bovine albumin, egg albumin, milk, casein, glutamine, alanine, fat, muscle and DNA. A table containing some characteristic parameters of the LAXS profiles of these samples is also presented. Analysis of measured profiles shows that all lyophilized samples produce at least one relatively broad peak at a scattering angle around 10.35 deg. The full width at half maximum (FWHM) of this peak varies considerably among the measured samples. Except for milk and casein, one additional peak at a scattering angle around 4.65 deg. is observed only in the LAXS profiles of proteins or protein-rich samples. This fact strongly suggests protein to be the biological macromolecule from which this characteristic peak originates. The same idea is further strengthened through discussion of some previous observations. (author)

  14. Characterization of Nanocellulose Using Small-Angle Neutron, X-ray, and Dynamic Light Scattering Techniques.

    Science.gov (United States)

    Mao, Yimin; Liu, Kai; Zhan, Chengbo; Geng, Lihong; Chu, Benjamin; Hsiao, Benjamin S

    2017-02-16

    Nanocellulose extracted from wood pulps using TEMPO (2,2,6,6-tetramethylpiperidine-1-oxyl radical)-mediated oxidation and sulfuric acid hydrolysis methods was characterized by small-angle neutron scattering (SANS), small-angle X-ray scattering (SAXS), and dynamic light scattering (DLS) techniques. The dimensions of this nanocellulose (TEMPO-oxidized cellulose nanofiber (TOCN) and sulfuric acid hydrolyzed cellulose nanocrystal (SACN)) revealed by the different scattering methods were compared with those characterized by transmission electron microscopy (TEM). The SANS and SAXS data were analyzed using a parallelepiped-based form factor. The width and thickness of the nanocellulose cross section were ∼8 and ∼2 nm for TOCN and ∼20 and ∼3 nm for SACN, respectively, where the fitting results from SANS and SAXS profiles were consistent with each other. DLS was carried out under both the VV mode with the polarizer and analyzer parallel to each other and the HV mode having them perpendicular to each other. Using rotational and translational diffusion coefficients obtained under the HV mode yielded a nanocellulose length qualitatively consistent with that observed by TEM, whereas the length derived by the translational diffusion coefficient under the VV mode appeared to be overestimated.

  15. Momentum-resolved resonant inelastic X-ray scattering on a single crystal under high pressure.

    Science.gov (United States)

    Yoshida, Masahiro; Ishii, Kenji; Jarrige, Ignace; Watanuki, Tetsu; Kudo, Kazutaka; Koike, Yoji; Kumagai, Ken'ichi; Hiraoka, Nozomu; Ishii, Hirofumi; Tsuei, Ku-Ding; Mizuki, Jun'ichiro

    2014-01-01

    A single-crystal momentum-resolved resonant inelastic X-ray scattering (RIXS) experiment under high pressure using an originally designed diamond anvil cell (DAC) is reported. The diamond-in/diamond-out geometry was adopted with both the incident and scattered beams passing through a 1 mm-thick diamond. This enabled us to cover wide momentum space keeping the scattering angle condition near 90°. Elastic and inelastic scattering from the diamond was drastically reduced using a pinhole placed after the DAC. Measurement of the momentum-resolved RIXS spectra of Sr2.5Ca11.5Cu24O41 at the Cu K-edge was thus successful. Though the inelastic intensity becomes weaker by two orders than the ambient pressure, RIXS spectra both at the center and the edge of the Brillouin zone were obtained at 3 GPa and low-energy electronic excitations of the cuprate were found to change with pressure.

  16. Temperature dependence of resonant x-ray magnetic scattering in holmium

    Science.gov (United States)

    Helgesen, G.; Hill, J. P.; Thurston, T. R.; Gibbs, Doon; Kwo, J.; Hong, M.

    1994-08-01

    We report the results of resonant x-ray magnetic scattering experiments on bulk and thin-film single crystals of holmium. The scattering at the principal magnetic reflection has been characterized as a function of the temperature in the spiral phases near and below their respective Néel temperatures. The integrated intensity of the principal magnetic peak in both samples shows power-law behavior versus reduced temperature with nearly equal exponents. The exponents for the scattering at the resonant second and third harmonics in the bulk sample are not simple integer multiples of the first, and motivate the consideration of simple scaling corrections to mean-field theory. We also present and compare the results of high-resolution measurements of the temperature dependence of the magnetic wave vectors, c-axis lattice constants, and correlation lengths of the magnetic scattering of the two samples in their spiral phases. Although the qualitative behavior is similar, systematic differences are found, including uniformly larger magnetic wave vectors and the suppression of the 1/6 phase in the film. The spiral magnetic structure of the film forms a domain state at all temperatures in the ordered phase. The magnetic correlation lengths of both samples are greatest near the Néel temperature, where that of the film appears to exceed the translational correlation lengths of the lattice. As the temperature decreases, the magnetic correlation lengths also decrease. These results are discussed in terms of the strain present in the samples.

  17. Joint small-angle X-ray and neutron scattering data analysis of asymmetric lipid vesicles.

    Science.gov (United States)

    Eicher, Barbara; Heberle, Frederick A; Marquardt, Drew; Rechberger, Gerald N; Katsaras, John; Pabst, Georg

    2017-04-01

    Low- and high-resolution models describing the internal transbilayer structure of asymmetric lipid vesicles have been developed. These models can be used for the joint analysis of small-angle neutron and X-ray scattering data. The models describe the underlying scattering length density/electron density profiles either in terms of slabs or through the so-called scattering density profile, previously applied to symmetric lipid vesicles. Both models yield structural details of asymmetric membranes, such as the individual area per lipid, and the hydrocarbon thickness of the inner and outer bilayer leaflets. The scattering density profile model, however, comes at a cost of increased computational effort but results in greater structural resolution, showing a slightly lower packing of lipids in the outer bilayer leaflet of ∼120 nm diameter palmitoyl-oleoyl phosphatidyl-choline (POPC) vesicles, compared to the inner leaflet. Analysis of asymmetric dipalmitoyl phosphatidylcholine/POPC vesicles did not reveal evidence of transbilayer coupling between the inner and outer leaflets at 323 K, i.e. above the melting transition temperature of the two lipids.

  18. Structural Studies of Bleached Melanin by Synchrotron Small-angle X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Littrell, Kenneth C.; Gallas, James M.; Zajac, Gerry W.; Thiyagarajan, Pappannan

    2003-01-01

    Small-angle X-ray scattering was used to measure the effects of chemical bleaching on the size and morphology of tyrosine-derived synthetic melanin dispersed in aqueous media. The average size as measured by the radius of gyration of the melanin particles in solution, at neutral to mildly basic pH, decreases from 16.5 to 12.5 angstroms with increased bleaching. The melanin particles exhibit scattering characteristic of sheet-like structures with a thickness of approximately 11 angstroms at all but the highest levels of bleaching. The scattering data are well described by the form factor for scattering from a pancake-like circular cylinder. These data are consistent with the hypothesis that unbleached melanin, at neutral to mildly basic pH, is a planar aggregate of 6- to 10-nm-sized melanin protomolecules, hydrogen bonded through their quinone and phenolic perimeters. The observed decrease in melanin particle size with increased bleaching is interpreted as evidence for deaggregation, most probably the result of oxidative disruption of hydrogen bonds and an increase in the number of charged, carboxylic acid groups, whereby the melanin aggregates disassociate into units composed of decreasing numbers of protomolecules.

  19. Foreign body detection in food materials using compton scattered x-rays

    Science.gov (United States)

    McFarlane, Nigel James Bruce

    This thesis investigated the application of X-ray Compton scattering to the problem of foreign body detection in food. The methods used were analytical modelling, simulation and experiment. A criterion was defined for detectability, and a model was developed for predicting the minimum time required for detection. The model was used to predict the smallest detectable cubes of air, glass, plastic and steel. Simulations and experiments were performed on voids and glass in polystyrene phantoms, water, coffee and muesli. Backscatter was used to detect bones in chicken meat. The effects of geometry and multiple scatter on contrast, signal-to-noise, and detection time were simulated. Compton scatter was compared with transmission, and the effect of inhomogeneity was modelled. Spectral shape was investigated as a means of foreign body detection. A signal-to-noise ratio of 7.4 was required for foreign body detection in food. A 0.46 cm cube of glass or a 1.19 cm cube of polystyrene were detectable in a 10 cm cube of water in one second. The minimum time to scan a whole sample varied as the 7th power of the foreign body size, and the 5th power of the sample size. Compton scatter inspection produced higher contrasts than transmission, but required longer measurement times because of the low number of photon counts. Compton scatter inspection of whole samples was very slow compared to production line speeds in the food industry. There was potential for Compton scatter in applications which did not require whole-sample scanning, such as surface inspection. There was also potential in the inspection of inhomogeneous samples. The multiple scatter fraction varied from 25% to 55% for 2 to 10 cm cubes of water, but did not have a large effect on the detection time. The spectral shape gave good contrasts and signal-to-noise ratios in the detection of chicken bones.

  20. Low-angle X-ray scattering properties of irradiated spices

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, A.P.G. [Nuclear Instrumentation Laboratory (LIN/COPPE), P. O. Box 68509, 21945-970, Rio de Janeiro RJ (Brazil)], E-mail: delson@lin.ufrj.br; Braz, D. [Nuclear Instrumentation Laboratory (LIN/COPPE), P. O. Box 68509, 21945-970, Rio de Janeiro RJ (Brazil); Barroso, R.C. [Physics Institute (IF/UERJ), University of Rio de Janeiro State, 20550-900 Rio de Janeiro RJ (Brazil); Lopes, R.T. [Nuclear Instrumentation Laboratory (LIN/COPPE), P. O. Box 68509, 21945-970, Rio de Janeiro RJ (Brazil)

    2007-09-21

    The scattering of X-rays at low angles (LAXS) is a technique dominated by the coherent scattering process. One characteristic observation of low-angle coherent scattering is the so-called molecular interference effect, being characterized by the presence of one or more peaks in the forward direction of scattering. In the present study, LAXS profiles from five different spices are carefully measured in order to establish characteristic scattering signatures. Samples of Ceylon cinnamon, cumin, nutmeg, paprika and black pepper were bought in local market in Rio de Janeiro, Brazil. The LAXS patterns were obtained using a Shimadzu DRX 6000 diffractometer in reflection geometry. Coherent scattering patterns are measured for the samples for {theta}=5-35{sup o}. The data were collected in 0.05{sup o} increments every 3 s. In order to evaluate the possible molecular structure changes caused to the irradiation procedure, the signatures obtained for control (non-irradiated) spices were compared with spice samples irradiated with different doses varying from 3 to 40 kGy. The LAXS patterns of all samples were obtained after 30, 60, 90, 120 days to evaluate the effect of storage period. Scattering profiles from spices irradiated with different irradiation doses were obtained and the results compared. For each spice, there is no considerable deviation in shape in function of the irradiation dose. It indicates that the molecular structure of each analyzed spices is preserved considering the dose range chosen. The results show that the molecular structure was found to be stable during storage at the ambient temperature for up to 4 months.

  1. Low-angle X-ray scattering properties of irradiated spices

    Science.gov (United States)

    Almeida, A. P. G.; Braz, D.; Barroso, R. C.; Lopes, R. T.

    2007-09-01

    The scattering of X-rays at low angles (LAXS) is a technique dominated by the coherent scattering process. One characteristic observation of low-angle coherent scattering is the so-called molecular interference effect, being characterized by the presence of one or more peaks in the forward direction of scattering. In the present study, LAXS profiles from five different spices are carefully measured in order to establish characteristic scattering signatures. Samples of Ceylon cinnamon, cumin, nutmeg, paprika and black pepper were bought in local market in Rio de Janeiro, Brazil. The LAXS patterns were obtained using a Shimadzu DRX 6000 diffractometer in reflection geometry. Coherent scattering patterns are measured for the samples for θ=5-35°. The data were collected in 0.05° increments every 3 s. In order to evaluate the possible molecular structure changes caused to the irradiation procedure, the signatures obtained for control (non-irradiated) spices were compared with spice samples irradiated with different doses varying from 3 to 40 kGy. The LAXS patterns of all samples were obtained after 30, 60, 90, 120 days to evaluate the effect of storage period. Scattering profiles from spices irradiated with different irradiation doses were obtained and the results compared. For each spice, there is no considerable deviation in shape in function of the irradiation dose. It indicates that the molecular structure of each analyzed spices is preserved considering the dose range chosen. The results show that the molecular structure was found to be stable during storage at the ambient temperature for up to 4 months.

  2. Introducing a standard method for experimental determination of the solvent response in laser pump, x-ray probe time-resolved wide-angle x-ray scattering experiments on systems in solution

    DEFF Research Database (Denmark)

    Kjær, Kasper Skov; Brandt van Driel, Tim; Kehres, Jan

    2013-01-01

    In time-resolved laser pump, X-ray probe wide-angle X-ray scattering experiments on systems in solution the structural response of the system is accompanied by a solvent response. The solvent response is caused by reorganization of the bulk solvent following the laser pump event, and in order to ...

  3. The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Braicovich, L., E-mail: lucio.braicovich@polimi.it; Minola, M.; Dellea, G.; Ghiringhelli, G. [CNR-SPIN and Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo Da Vinci 32, Milano I-20133 (Italy); Le Tacon, M. [Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart (Germany); Moretti Sala, M.; Morawe, C.; Peffen, J.-Ch.; Yakhou, F.; Brookes, N. B. [European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043 (France); Supruangnet, R. [Synchrotron Light Research Institute, Nakhon Ratchasima (Thailand)

    2014-11-15

    Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B{sub 4}C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L{sub 3} edge on a high-T{sub c} superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

  4. Resonant x-ray scattering in perovskite manganite superlattice. Observation of 'orbital superlattice'

    CERN Document Server

    Kiyama, T; Ohsumi, H; Murakami, Y; Wakabayashi, Y; Izumi, M; Kawasaki, M; Tokura, Y

    2003-01-01

    We report the results of resonant X-ray scattering (RXS) measurement of superlattices which consist of La sub 0 sub . sub 4 sub 5 Sr sub 0 sub . sub 5 sub 5 MnO sub 3 and La sub 0 sub . sub 6 sub 0 Sr sub 0 sub . sub 4 sub 0 MnO sub 3 multilayers. An interference technique made it possible to observe RXS reflections from ferro-type orbital ordering in the superlattices. RXS can reveal the local circumstances around specific atoms in materials regulated atomically. In this experiment, we observed that the superlattice is actually composed of two kinds of layers with different lattice distortion states, presenting 'orbital superlattices', in which layers with different orbital states are stacked alternately in an atomic scale. (author)

  5. Small-angle x-ray scattering study of polymer structure: Carbosilane dendrimers in hexane solution

    Science.gov (United States)

    Shtykova, E. V.; Feigin, L. A.; Volkov, V. V.; Malakhova, Yu. N.; Streltsov, D. R.; Buzin, A. I.; Chvalun, S. N.; Katarzhanova, E. Yu.; Ignatieva, G. M.; Muzafarov, A. M.

    2016-09-01

    The three-dimensional organization of monodisperse hyper-branched macromolecules of regular structure—carbosilane dendrimers of zero, third, and sixth generations—has been studied by small-angle X-ray scattering (SAXS) in solution. The use of modern methods of SAXS data interpretation, including ab initio modeling, has made it possible to determine the internal architecture of the dendrimers in dependence of the generation number and the number of cyclosiloxane end groups (forming the shell of dendritic macromolecules) and show dendrimers to be spherical. The structural results give grounds to consider carbosilane dendrimers promising objects for forming crystals with subsequent structural analysis and determining their structure with high resolution, as well as for designing new materials to be used in various dendrimer-based technological applications.

  6. Robust, high-throughput solution structural analyses by small angle X-ray scattering (SAXS)

    Energy Technology Data Exchange (ETDEWEB)

    Hura, Greg L.; Menon, Angeli L.; Hammel, Michal; Rambo, Robert P.; Poole II, Farris L.; Tsutakawa, Susan E.; Jenney Jr, Francis E.; Classen, Scott; Frankel, Kenneth A.; Hopkins, Robert C.; Yang, Sungjae; Scott, Joseph W.; Dillard, Bret D.; Adams, Michael W. W.; Tainer, John A.

    2009-07-20

    We present an efficient pipeline enabling high-throughput analysis of protein structure in solution with small angle X-ray scattering (SAXS). Our SAXS pipeline combines automated sample handling of microliter volumes, temperature and anaerobic control, rapid data collection and data analysis, and couples structural analysis with automated archiving. We subjected 50 representative proteins, mostly from Pyrococcus furiosus, to this pipeline and found that 30 were multimeric structures in solution. SAXS analysis allowed us to distinguish aggregated and unfolded proteins, define global structural parameters and oligomeric states for most samples, identify shapes and similar structures for 25 unknown structures, and determine envelopes for 41 proteins. We believe that high-throughput SAXS is an enabling technology that may change the way that structural genomics research is done.

  7. In Situ X ray scattering for investing morphology of bottle brush BCP with Solvent annealing

    Science.gov (United States)

    Jeong, Gajin; Russell, Thomas P.; Sveinbjornsson, Benjamin R.; Grubbs, Robert H.; Univ of Mass-Amherst Collaboration; California Institute of Technology Collaboration

    2014-03-01

    We investigated the morphology of bottle-brush block copolymer (BrBCPs) thin films using solvent vapor annealing (SVA) in a specially designed chamber for in situgrazing incidence x-ray scattering. BrBCPs with polystyrene (PS) and poly(lactic acid) (PLA) side chains and a norbornene backbone were studied SVA using THF, a good solvent for PS and PLA, a controlled swelling and deswelling rate were achieved with N2 carrier gas. Film thickness was monitored by optical interferometry. The interference maximum, characteristic of the microdomain morphology, was found to vary linearly with molecular weight. The in situGISAXS measuremens were used to elucidate the evolution of the morphology in the thin films.

  8. Online ion-exchange chromatography for small-angle X-ray scattering.

    Science.gov (United States)

    Hutin, Stephanie; Brennich, Martha; Maillot, Benoit; Round, Adam

    2016-10-01

    Biological small-angle X-ray scattering (BioSAXS) is a powerful technique to determine the solution structure, particle size, shape and surface-to-volume ratio of macromolecules. However, a drawback is that the sample needs to be monodisperse. To ensure this, size-exclusion chromatography (SEC) has been implemented on many BioSAXS beamlines. Here, the integration of ion-exchange chromatography (IEC) using both continuous linear and step gradients on a beamline is described. Background subtraction for continuous gradients by shifting a reference measurement and two different approaches for step gradients, which are based on interpolating between two background measurements, are discussed. The results presented here serve as a proof of principle for online IEC and subsequent data treatment.

  9. Inelastic X-ray scattering on liquid benzene analyzed using a generalized Langevin equation

    Science.gov (United States)

    Yoshida, Koji; Fukuyama, Nami; Yamaguchi, Toshio; Hosokawa, Shinya; Uchiyama, Hiroshi; Tsutsui, Satoshi; Baron, Alfred Q. R.

    2017-07-01

    The dynamic structure factor, S(Q,ω), of liquid benzene was measured by meV-resolved inelastic X-ray scattering (IXS) and analyzed using a generalized Langevin model with a memory function including fast, μ-relaxation and slow, structural, α-relaxation. The model well reproduced the experimental S(Q,ω) of liquid benzene. The dispersion relation of the collective excitation energy yields the high-frequency sound velocity for liquid benzene as related to the α-relaxation. The ratio of the high-frequency to the adiabatic sound velocity is approximately 1.5, larger to that of carbon tetrachloride and smaller than those of methanol and water, reflecting the nature of intermolecular interactions.

  10. Auxiliary fermion approach to the resonant inelastic x-ray scattering response in an underdoped cuprate

    Science.gov (United States)

    Shi, Yifei; James, Andrew J. A.; Demler, Eugene; Klich, Israel

    2017-10-01

    We describe a method for calculating the resonant inelastic x-ray scattering (RIXS) response—including the dynamics of the transient core hole—of many-body systems with nontrivial gap structure encoded in their single particle Green's function. Our approach introduces auxiliary fermions in order to obtain a form amenable to the determinant method of Benjamin et al., [Phys. Rev. Lett. 112, 247002 (2014), 10.1103/PhysRevLett.112.247002], and is applicable to systems where interactions are most strongly felt through a renormalization of the single particle propagator. As a test case we consider the Yang-Rice-Zhang ansatz for cuprate phenomena in the underdoped "pseudogap" regime, which remains a popular tool for interpreting the results of experimental probes. We show that taking the core hole dynamics into account for a system described by this ansatz pushes the RIXS peaks towards higher energy transfer, improving agreement with experiments.

  11. Heterogeneities in CuZr-based bulk metallic glasses studied by x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X D; Lou, H B; Gong, Y; Jiang, J Z [International Center for New-Structured Materials (ICNSM), Zhejiang University (China); Vainio, U, E-mail: wangxd@zju.edu.cn, E-mail: jiangjz@zju.edu.cn [HASYLAB at DESY, Notkestrasse 85, D-22607 Hamburg (Germany)

    2011-02-23

    Inhomogeneities in two CuZr-based bulk metallic glasses (BMGs) were studied by using synchrotron radiation x-ray scattering techniques. (Cu{sub 4.5/5.5}Ag{sub 1/5.5}){sub 46}Zr{sub 46}Al{sub 8} BMG was found to be more inhomogeneous than Cu{sub 46}Zr{sub 46}Al{sub 8} BMG on the small length scale, where Cu and Ag atoms form enriched zones. Such heterogeneities are locally favorable for forming close-packed icosahedron-like clusters in three-dimensional space, greatly promoting the glass forming ability of this alloy. Upon annealing near the T{sub g} temperature, the heterogeneities were reduced initially at low temperature and short time annealing, then regenerated again for temperature increase and time extension. The average environment around Zr atoms almost does not change. However, the heterogeneity increases for Cu, Zr and Ag atoms once nanocrystallization happens.

  12. Some notes on data analysis for nuclear resonant inelastic x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Michael Y., E-mail: myhu@aps.anl.gov [Argonne National Laboratory (United States)

    2016-12-15

    Nuclear Resonant Inelastic X-ray Scattering (NRIXS) is a spectroscopy method to study atomic vibrations and dynamics, currently done with synchrotron radiation at a few high energy third generation facilities. It finds a wide range of applications in condensed matter physics, materials science, chemistry, biophysics, geosciences, and high-pressure researches. Many atomic dynamics and lattice thermodynamics information can be derived from NRIXS measurements. Phonon Density of States (DOS) characterizes lattice dynamics of a material and can be derived under the quasi-harmonic approximation. Combined with modeling and simulations, results from NRIXS can provide unique and clarifying insights into many fields of research. As for a spectroscopic technique, in order to be able to provide reliable information, close attention should be paid to many issues during experiments and data analysis afterwards. Here we discuss several issues relevant to its data analysis, namely, those of multiple sites, background treatments, and error estimates for some derived quantities.

  13. Super-resolution in solution X-ray scattering and its applications to structural systems biology.

    Science.gov (United States)

    Rambo, Robert P; Tainer, John A

    2013-01-01

    Small-angle X-ray scattering (SAXS) is a robust technique for the comprehensive structural characterizations of biological macromolecular complexes in solution. Here, we present a coherent synthesis of SAXS theory and experiment with a focus on analytical tools for accurate, objective, and high-throughput investigations. Perceived SAXS limitations are considered in light of its origins, and we present current methods that extend SAXS data analysis to the super-resolution regime. In particular, we discuss hybrid structural methods, illustrating the role of SAXS in structure refinement with NMR and ensemble refinement with single-molecule FRET. High-throughput genomics and proteomics are far outpacing macromolecular structure determinations, creating information gaps between the plethora of newly identified genes, known structures, and the structure-function relationship in the underlying biological networks. SAXS can bridge these information gaps by providing a reliable, high-throughput structural characterization of macromolecular complexes under physiological conditions.

  14. X-RAY VARIABILITY STUDY OF POLAR SCATTERED SEYFERT1 GALAXIES

    Directory of Open Access Journals (Sweden)

    Tobias Beuchert

    2014-08-01

    Full Text Available We study 12 Seyfert 1 galaxies with a high level of optical polarization. Optical light emerging from the innermost regions is predominantly scattered in a polar region above the central engine directly in our line of sight. These sources show characteristics of Seyfert 2 galaxies, e.g. polarized broad lines. The polarization signatures suggest a viewing angle of 45°, classifying them as intermediate Seyfert 1/2 types. The unified model predicts this line of sight to pass through the outer layer of the torus resulting in significant soft X-ray variability due to a strongly varying column density. The aim is to find evidence for this geometrical assumption in the spectral variability of all available historical observations of these sources by XMM-Newton and Swift.

  15. Asymmetrical bonding in liquid Bi disentangled by inelastic X-ray scattering

    Science.gov (United States)

    Inui, Masanori; Kajihara, Yukio; Munejiri, Shuji; Hosokawa, Shinya; Chiba, Ayano; Ohara, Koji; Tsutsui, Satoshi; Baron, Alfred Q. R.

    2017-08-01

    The structure of liquid Bi has been debated in relationship with the Peierls distortion, as crystalline Bi takes A7 structure. A recent ab initio molec- ular dynamics simulation for liquid Bi predicted a flat-topped profile of the acoustic dispersion curve. To confirm the prediction, we have carried out inelas- tic x-ray scattering (IXS) for liquid Bi. The dynamic structure factor obtained by the IXS exhibits a distinct inelastic excitation of the longitudinal acoustic mode up to 14 nm-1 and the dispersion curve of the excitation energy obtained by the memory function analysis becomes a flat-topped one. We found that a linear chain model including the interatomic interaction with the second near- est neighbors can explain the flat-topped profile. The result suggests that the anomalous dispersion curve in liquid Bi arises from local anisotropy related to the Peierls distortion in the crystalline phase. .

  16. Resonant inelastic soft x-ray scattering studies of U(VI)reduction on iron surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Butorin, S.M.; Shuh, D.K.; Kvashnina, K.; Soroka, I.; Ollila, K.; Guo, J.-H.; Roberts, K.E.; Werme, L.; Nordgren, J.

    2003-11-01

    We report on the spectroscopic analysis of several samples relevant to the processes governing the behavior of oxidized uranium species in groundwater solutions under anoxic conditions. Both Fe samples with different times of exposure to the U(IV) solution and Fe metal solution interfaces in the liquid cell ex-situ and in-situ, respectively. Resonant inelastic soft x-ray scattering is shown to be sensitive to the chemical state of uranium. The measurements were performed at a number of energies of the primary photon beam across the U 5d absorption edge. The results unambiguously indicate the reduction of U(VI) to U(IV) on the Fe surface.

  17. Structural characterization of cellulosic materials using x-ray and neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Penttila, P.

    2013-11-01

    Cellulosic biomass can be used as a feedstock for sustainable production of biofuels and various other products. A complete utilization of the raw material requires understanding on its structural aspects and their role in the various processes. In this thesis, x-ray and neutron scattering methods were applied to study the structure of various cellulosic materials and how they are affected in different processes. The obtained results were reviewed in the context of a model for the cellulose nanostructure. The dimensions of cellulose crystallites and the crystallinity were determined with wide-angle x-ray scattering (WAXS), whereas the nanoscale fibrillar structure of cellulose was characterized with small-angle x-ray and neutron scattering (SAXS and SANS). The properties determined with the small-angle scattering methods included specific surface areas and distances characteristic of the packing of cellulose microfibrils. Also other physical characterization methods, such as x-ray microtomography, infrared spectroscopy, and solid-state NMR were utilized in this work. In the analysis of the results, a comprehensive understanding of the structural changes throughout a range of length scales was aimed at. Pretreatment of birch sawdust by pressurized hot water extraction was observed to increase the crystal width of cellulose, as determined with WAXS, even though the cellulose crystallinity was slightly decreased. A denser packing of microfibrils caused by the removal of hemicelluloses and lignin in the extraction was evidenced by SAXS. This resulted in the opening of new pores between the microfibril bundles and an increase of the specific surface area. Enzymatic hydrolysis of microcrystalline cellulose (MCC) did not lead to differences in the average crystallinity or crystal size of the hydrolysis residues, which was explained to be caused by limitations due to the large size of the enzymes as compared to the pores inside the fibril aggregates. The SAXS intensities

  18. Seeing real-space dynamics of liquid water through inelastic x-ray scattering.

    Science.gov (United States)

    Iwashita, Takuya; Wu, Bin; Chen, Wei-Ren; Tsutsui, Satoshi; Baron, Alfred Q R; Egami, Takeshi

    2017-12-01

    Water is ubiquitous on earth, but we know little about the real-space motion of molecules in liquid water. We demonstrate that high-resolution inelastic x-ray scattering measurement over a wide range of momentum and energy transfer makes it possible to probe real-space, real-time dynamics of water molecules through the so-called Van Hove function. Water molecules are found to be strongly correlated in space and time with coupling between the first and second nearest-neighbor molecules. The local dynamic correlation of molecules observed here is crucial to a fundamental understanding of the origin of the physical properties of water, including viscosity. The results also suggest that the quantum-mechanical nature of hydrogen bonds could influence its dynamics. The approach used here offers a powerful experimental method for investigating real-space dynamics of liquids.

  19. Solution x-ray scattering and structure formation in protein dynamics

    Science.gov (United States)

    Nasedkin, Alexandr; Davidsson, Jan; Niemi, Antti J.; Peng, Xubiao

    2017-12-01

    We propose a computationally effective approach that builds on Landau mean-field theory in combination with modern nonequilibrium statistical mechanics to model and interpret protein dynamics and structure formation in small- to wide-angle x-ray scattering (S/WAXS) experiments. We develop the methodology by analyzing experimental data in the case of Engrailed homeodomain protein as an example. We demonstrate how to interpret S/WAXS data qualitatively with a good precision and over an extended temperature range. We explain experimental observations in terms of protein phase structure, and we make predictions for future experiments and for how to analyze data at different ambient temperature values. We conclude that the approach we propose has the potential to become a highly accurate, computationally effective, and predictive tool for analyzing S/WAXS data. For this, we compare our results with those obtained previously in an all-atom molecular dynamics simulation.

  20. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing.

    Science.gov (United States)

    Ramamurthy, Senthil; D'Orsi, Carl J; Sechopoulos, Ioannis

    2016-02-07

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360° with a perforated tungsten plate in the path of the x-ray beam. To make patient testing feasible, a wirelessly controlled electronic positioner for the tungsten plate was designed and added to a breast CT system. Other improvements to the algorithm were implemented, including automated exclusion of non-valid primary estimate points and the use of a different approximation method to estimate the full scatter signal. To evaluate the effectiveness of the algorithm, evaluation of the resulting image quality was performed with a breast phantom and with nine patient images. The improvements in the algorithm resulted in the avoidance of introduction of artifacts, especially at the object borders, which was an issue in the previous implementation in some cases. Both contrast, in terms of signal difference and signal difference-to-noise ratio were improved with the proposed method, as opposed to with the correction algorithm incorporated in the system, which does not recover contrast. Patient image evaluation also showed enhanced contrast, better cupping correction, and more consistent voxel values for the different tissues. The algorithm also reduces artifacts present in reconstructions of non-regularly shaped breasts. With the implemented hardware and software improvements, the proposed method can be reliably used during patient breast CT imaging, resulting in improvement of image quality, no introduction of artifacts, and in some cases reduction of artifacts already present. The impact of the algorithm on actual clinical performance for detection, diagnosis and other clinical tasks in breast imaging remains to be evaluated.

  1. A triple axis double crystal multiple reflection camera for ultra small angle X-ray scattering

    Science.gov (United States)

    Lambard, Jacques; Lesieur, Pierre; Zemb, Thomas

    1992-06-01

    To extend the domain of small angle X-ray scattering requires multiple reflection crystals to collimate the beam. A double crystal, triple axis X-ray camera using multiple reflection channel cut crystals is described. Procedures for measuring the desmeared scattering cross-section on absolute scale are described as well as the measurement from several typical samples : fibrils of collagen, 0.3 μm diameter silica spheres, 0.16 μm diameter interacting latex spheres, porous lignite coal, liquid crystals in a surfactant-water system, colloidal crystal of 0.32 μm diameter silica spheres. L'extension du domaine de diffusion des rayons-X vers les petits angles demande l'emploi de cristaux à réflexions multiples pour collimater le faisceau. Nous décrivons une caméra à rayons-X à trois axes où les réflexions multiples sont réalisées dans deux cristaux à gorge. Nous donnons ensuite les procédures de déconvolution pour obtenir la section efficace de diffusion en échelle absolue, ainsi que les résultats des mesures effectuées avec plusieurs échantillons typiques : fibres de collagène, sphères de silice de 0,3 μm de diamètre, sphères de latex de 0,16 μm de diamètre en interaction, charbon lignite poreux, cristaux liquides formés dans un système eau-tensioactif, solution colloïdale de sphères de silice de 0,32 μm de diamètre.

  2. Photon activated therapy (PAT using monochromatic Synchrotron x-rays and iron oxide nanoparticles in a mouse tumor model: feasibility study of PAT for the treatment of superficial malignancy

    Directory of Open Access Journals (Sweden)

    Choi Gi-Hwan

    2012-10-01

    Full Text Available Abstract Background X-rays are known to interact with metallic nanoparticles, producing photoelectric species as radiosensitizing effects, and have been exploited in vivo mainly with gold nanoparticles. The purpose of this study was to investigate the potential of sensitizing effect of iron oxide nanoparticles for photon activated therapy. Methods X-rays photon activated therapy (PAT was studied by treating CT26 tumor cells and CT26 tumor-bearing mice loaded with 13-nm diameter FeO NP, and irradiating them at 7.1 keV near the Fe K-edge using synchrotron x-rays radiation. Survival of cells was determined by MTT assay, and tumor regression assay was performed for in vivo model experiment. The results of PAT treated groups were compared with x-rays alone control groups. Results A more significant reduction in viability and damage was observed in the FeO NP-treated irradiated cells, compared to the radiation alone group (p Conclusions An iron oxide nanoparticle enhanced therapeutic effect with relatively low tissue concentration of iron and 10 Gy of monochromatic X-rays. Since 7.1 keV X-rays is attenuated very sharply in the tissue, FeO NP-PAT may have promise as a potent treatment option for superficial malignancies in the skin, like chest wall recurrence of breast cancer.

  3. Observation of Laser Induced Magnetization Dynamics in Co/Pd Multilayers with Coherent X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Benny

    2012-04-05

    We report on time-resolved coherent x-ray scattering experiments of laser induced magnetization dynamics in Co/Pd multilayers with a high repetition rate optical pump x-ray probe setup. Starting from a multi-domain ground state, the magnetization is uniformly reduced after excitation by an intense 50 fs laser pulse. Using the normalized time correlation, we study the magnetization recovery on a picosecond timescale. The dynamic scattering intensity is separated into an elastic portion at length scales above 65 nm which retains memory of the initial domain magnetization, and a fluctuating portion at smaller length scales corresponding to domain boundary motion during recovery.

  4. Extreme UV and X-ray scattering measurements from a rough LiF crystal surface characterized by electron micrography

    DEFF Research Database (Denmark)

    Alehyane; Arbaoui; Barchewitz

    1989-01-01

    XUV and X-ray scattering by a LiF crystal is measured. The angular distribution of the scattered radiation (ADSR) reveals characteristic features, side peaks or asymmetry. The surface of the sample is statistically characterized by a microdensitometer analysis of electron micrographs resolving...... of the ADSR features in terms of the modulation of the surface power spectral density function associated with the microroughness by an optical factor. The possibility of obtaining short scale roughness characterization from XUV or X-ray measurements is discussed...

  5. Six-dimensional real and reciprocal space small-angle X-ray scattering tomography.

    Science.gov (United States)

    Schaff, Florian; Bech, Martin; Zaslansky, Paul; Jud, Christoph; Liebi, Marianne; Guizar-Sicairos, Manuel; Pfeiffer, Franz

    2015-11-19

    When used in combination with raster scanning, small-angle X-ray scattering (SAXS) has proven to be a valuable imaging technique of the nanoscale, for example of bone, teeth and brain matter. Although two-dimensional projection imaging has been used to characterize various materials successfully, its three-dimensional extension, SAXS computed tomography, poses substantial challenges, which have yet to be overcome. Previous work using SAXS computed tomography was unable to preserve oriented SAXS signals during reconstruction. Here we present a solution to this problem and obtain a complete SAXS computed tomography, which preserves oriented scattering information. By introducing virtual tomography axes, we take advantage of the two-dimensional SAXS information recorded on an area detector and use it to reconstruct the full three-dimensional scattering distribution in reciprocal space for each voxel of the three-dimensional object in real space. The presented method could be of interest for a combined six-dimensional real and reciprocal space characterization of mesoscopic materials with hierarchically structured features with length scales ranging from a few nanometres to a few millimetres--for example, biomaterials such as bone or teeth, or functional materials such as fuel-cell or battery components.

  6. Gauge invariance and relativistic effects in X-ray absorption and scattering by solids

    Science.gov (United States)

    Bouldi, Nadejda; Brouder, Christian

    2017-12-01

    There is an incompatibility between gauge invariance and the semi-classical time-dependent perturbation theory commonly used to calculate light absorption and scattering cross-sections. There is an additional incompatibility between perturbation theory and the description of the electron dynamics by a semi-relativistic Hamiltonian. In this paper, the gauge-dependence problem of exact perturbation theory is described, the proposed solutions are reviewed and it is concluded that none of them seems fully satisfactory. The problem is finally solved by using the fully relativistic absorption and scattering cross-sections given by quantum electrodynamics. Then, a new general Foldy-Wouthuysen transformation is presented. It is applied to the many-body case to obtain correct semi-relativistic transition operators. This transformation considerably simplifies the calculation of relativistic corrections. In the process, a new light-matter interaction term emerges, called the spin-position interaction, that contributes significantly to the magnetic X-ray circular dichroism of transition metals. We compare our result with the ones obtained by using several semi-relativistic time-dependent Hamiltonians. In the case of absorption, the final formula agrees with the result obtained from one of them. However, the correct scattering cross-section is not given by any of the semi-relativistic Hamiltonians.

  7. Analysis of the hierarchical structure of biological tissues by scanning X-ray scattering using a micro-beam.

    Science.gov (United States)

    Paris, O; Zizak, I; Lichtenegger, H; Roschger, P; Klaushofer, K; Fratzl, P

    2000-07-01

    The outstanding mechanical properties of biological tissues such as wood or bone are mainly due to their hierarchical structure and to their optimization at all levels of hierarchy. It is therefore essential to characterize the structure at all levels to understand the complex behavior of such tissues. Structures down to the micrometer level are accessible to light or scanning electron microscopic observation. In the case of bone this includes, for example, morphometry of the trabecular architecture or the bone mineral density distribution in cortical and trabecular bone. To characterize the sub-micrometer structure of, e.g., the collagen-mineral composite in the case of bone or the cellulose microfibrils in the case of wood, other methods, such as transmission electron microscopy or X-ray scattering are necessary. The recent availability of extremely brilliant synchrotron X-ray sources has led to the development of the new techniques of scanning small-angle X-ray scattering and scanning X-ray microdiffraction, which are capable of providing structural information on the micrometer and the nanometer level, simultaneously. As a basic principle of the method the specimen is scanned across an X-ray beam which has a diameter of few micrometers. Measuring the X-ray absorption at each position provides an image of the specimen (microradiography) with resolution similar to light microscopy, in the micrometer range. Moreover, the X-ray scattering pattern is analyzed at each specimen position to provide parameters characterizing the structure in the nanometer range. The present paper reviews the principles of the techniques and demonstrates their application to biological materials, such as wood or bone.

  8. Structural studies coupling X-ray diffraction and high-energy X-ray scattering in the UO2(2+)-HBr(aq) system.

    Science.gov (United States)

    Wilson, Richard E; Skanthakumar, S; Cahill, C L; Soderholm, L

    2011-11-07

    The structural chemistry of uranium(VI) in concentrated aqueous hydrobromic acid solutions was investigated using both single crystal X-ray diffraction and synchrotron-based high-energy X-ray scattering (HEXS) to reveal the structure of the uranium(VI) complexes in solution prior to crystallization. The crystal structures of a series of uranyl tetrabromide salts are reported, including Cs(2)UO(2)Br(4), Rb(2)UO(2)Br(4)·2H(2)O, K(2)UO(2)Br(4)·2H(2)O, and (NH(4))(2)UO(2)Br(4)·2H(2)O, as well as a molecular dimer of uranium(VI), (UO(2))(2)(OH)(2)Br(2)(H(2)O)(4). Limited correspondence exists between the structures observed in the solid state and those in solution. Quantitative analysis of the HEXS data show an average U-Br coordination number of 1.9(2) in solution, in contrast to the U-Br coordination number of 4 in the solid salts. © 2011 American Chemical Society

  9. Demonstration of a time-resolved x-ray scattering instrument utilizing the full-repetition rate of x-ray pulses at the Pohang Light Source

    Science.gov (United States)

    Jo, Wonhyuk; Eom, Intae; Landahl, Eric C.; Lee, Sooheyong; Yu, Chung-Jong

    2016-03-01

    We report on the development of a new experimental instrument for time-resolved x-ray scattering (TRXS) at the Pohang Light Source (PLS-II). It operates with a photon energy ranging from 5 to 18 keV. It is equipped with an amplified Ti:sappahire femtosecond laser, optical diagnostics, and laser beam delivery for pump-probe experiments. A high-speed single-element detector and high trigger-rate oscilloscope are used for rapid data acquisition. While this instrument is capable of measuring sub-nanosecond dynamics using standard laser pump/x-ray probe techniques, it also takes advantage of the dense 500 MHz standard fill pattern in the PLS-II storage ring to efficiently record nano-to-micro-second dynamics simultaneously. We demonstrate this capability by measuring both the (fast) impulsive strain and (slower) thermal recovery dynamics of a crystalline InSb sample following intense ultrafast laser excitation. Exploiting the full repetition rate of the storage ring results in a significant improvement in data collection rates compared to conventional bunch-tagging methods.

  10. Ultra-small-angle X-ray scattering-X-ray photon correlation spectroscopy studies of incipient structural changes in amorphous calcium phosphate-based dental composites.

    Science.gov (United States)

    Zhang, Fan; Allen, Andrew J; Levine, Lyle E; Espinal, Laura; Antonucci, Joseph M; Skrtic, Drago; O'Donnell, Justin N R; Ilavsky, Jan

    2012-05-01

    The local structural changes in amorphous calcium phosphate (ACP)-based dental composites were studied under isothermal conditions using both static, bulk measurement techniques and a recently developed methodology based on combined ultra-small angle X-ray scattering-X-ray photon correlation spectroscopy (USAXS-XPCS), which permits a dynamic approach. While results from conventional bulk measurements do not show clear signs of structural change, USAXS-XPCS results reveal unambiguous evidence for local structural variations on a similar time scale to that of water loss in the ACP fillers. A thermal-expansion-based simulation indicates that thermal behavior alone does not account for the observed dynamics. Together, these results suggest that changes in the water content of ACP affect the composite morphology due to changes in ACP structure that occur without an amorphous-to-crystalline conversion. It is also noted that biomedical materials research could benefit greatly from USAXS-XPCS, a dynamic approach. Copyright © 2012 Wiley Periodicals, Inc.

  11. Magnetic hysteresis of an artificial square ice studied by in-plane Bragg x-ray resonant magnetic scattering

    Directory of Open Access Journals (Sweden)

    J. P. Morgan

    2012-06-01

    Full Text Available We report X-ray resonant magnetic scattering studies of a Permalloy artificial square ice nanomagnet array, focussing on the field-driven evolution of the sum Σ and difference Δ signals of left and right handed circularly polarized synchrotron X-rays at different lateral positions in reciprocal space Qx. We used X-rays tuned to the Fe L3 resonance energy, with the scattering plane aligned along a principal symmetry axis of the array. Details of the specular Δ hysteresis curve are discussed, following the system magnetization from an initial demagnetized state. The periodic structure gives rise to distinct peaks at in-plane reciprocal Bragg positions, as shown by fitting Σ(Qx to a model based on a simple unit cell structure. Diffraction order-dependent hysteresis in Δ is observed, indicative of the reordering of magnetization on the system's two interpenetrating sublattices, which markedly deviates from an ideal Ising picture under strong applied fields.

  12. Magnetic hysteresis of an artificial square ice studied by in-plane Bragg x-ray resonant magnetic scattering

    Science.gov (United States)

    Morgan, J. P.; Kinane, C. J.; Charlton, T. R.; Stein, A.; Sánchez-Hanke, C.; Arena, D. A.; Langridge, S.; Marrows, C. H.

    2012-06-01

    We report X-ray resonant magnetic scattering studies of a Permalloy artificial square ice nanomagnet array, focussing on the field-driven evolution of the sum Σ and difference Δ signals of left and right handed circularly polarized synchrotron X-rays at different lateral positions in reciprocal space Qx. We used X-rays tuned to the Fe L3 resonance energy, with the scattering plane aligned along a principal symmetry axis of the array. Details of the specular Δ hysteresis curve are discussed, following the system magnetization from an initial demagnetized state. The periodic structure gives rise to distinct peaks at in-plane reciprocal Bragg positions, as shown by fitting Σ(Qx) to a model based on a simple unit cell structure. Diffraction order-dependent hysteresis in Δ is observed, indicative of the reordering of magnetization on the system's two interpenetrating sublattices, which markedly deviates from an ideal Ising picture under strong applied fields.

  13. Using X-ray Thomson Scattering to Characterize Highly Compressed, Near-Degenerate Plasmas at the NIF

    Science.gov (United States)

    Doeppner, Tilo; Kraus, D.; Neumayer, P.; Bachmann, B.; Divol, L.; Kritcher, A. L.; Landen, O. L.; Fletcher, L.; Glenzer, S. H.; Falcone, R. W.; MacDonald, M. J.; Saunders, A.; Witte, B.; Redmer, R.; Chapman, D.; Baggott, R.; Gericke, D. O.; Yi, S. A.

    2017-10-01

    We are developing x-ray Thomson scattering for implosion experiments at the National Ignition Facility to characterize plasma conditions in plastic and beryllium capsules near stagnation, reaching more than 20x compression and electron densities of 1025 cm-3, corresponding to a Fermi energy of 170 eV. Using a zinc He- α x-ray source at 9 keV, experiments at a large scattering angle of 120° measure non-collective scattering spectra with high sensitivity to K-shell ionization, and find higher charge states than predicted by widely used ionization models. Reducing the scattering angle to 30° probes the collective scattering regime with sensitivity to collisions and conductivity. We will discuss recent results and future plans. This work was performed under the auspices of the US Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  14. PREFACE: REXS 2013 - Workshop on Resonant Elastic X-ray Scattering in Condensed Matter

    Science.gov (United States)

    Beutier, G.; Mazzoli, C.; Yakhou, F.; Brown, S. D.; Bombardi, A.; Collins, S. P.

    2014-05-01

    The aim of this workshop was to bring together experts in experimental and theoretical aspects of resonant elastic x-ray scattering, along with researchers who are new to the field, to discuss important recent results and the fundamentals of the technique. The meeting was a great success, with the first day dedicated to students and new researchers in the field, who received introductory lectures and tutorials. All conference delegates were invited either to make an oral presentation or to present a poster, accompanied by a short talk. The first two papers selected for the REXS13 proceedings (Grenier & Joly and Helliwell) give a basic background to the theory of REXS and applications across a wide range of scientific areas. The remainder of the papers report on some of the latest scientific results obtained by applying the REXS technique to contemporary problems in condensed matter, materials and x-ray physics. It is hoped that these proceedings provide a snapshot of the current status of a vibrant and diverse scientific technique that will be of value not just to those who attended the workshop but also to any other reader with an interest in the subject. Local Scientific Committee REXS13 International Scientific Advisory Committee M Altarelli, European XFEL, Germany F de Bergevin, European Synchrotron Radiation Facility, France J Garcia-Ruiz, Universidad de Zaragoza, Spain A I Goldman, Iowa State University, USA M Goldmann, Institut Nanosciences, France T Schulli, European Synchrotron Radiation Facility, France C R Natoli, Laboratori Nazionali de Frascati, Italy G Materlik, Diamond Light Source, UK L Paolasini, European Synchrotron Radiation Facility, France U Staub, Paul Scherrer Institut, Switzerland K Finkelstein, Cornell University, USA Y Murakami, Photon Factory, Japan REXS13 Local Scientific Committee G Beutier, CNRS Grenoble, France C Mazzoli, Politecnico di Milano, Italy F Yakhou, European Synchrotron Radiation Facility, France S D Brown, XMaS UK CRG

  15. Calculation of accurate small angle X-ray scattering curves from coarse-grained protein models

    Directory of Open Access Journals (Sweden)

    Stovgaard Kasper

    2010-08-01

    Full Text Available Abstract Background Genome sequencing projects have expanded the gap between the amount of known protein sequences and structures. The limitations of current high resolution structure determination methods make it unlikely that this gap will disappear in the near future. Small angle X-ray scattering (SAXS is an established low resolution method for routinely determining the structure of proteins in solution. The purpose of this study is to develop a method for the efficient calculation of accurate SAXS curves from coarse-grained protein models. Such a method can for example be used to construct a likelihood function, which is paramount for structure determination based on statistical inference. Results We present a method for the efficient calculation of accurate SAXS curves based on the Debye formula and a set of scattering form factors for dummy atom representations of amino acids. Such a method avoids the computationally costly iteration over all atoms. We estimated the form factors using generated data from a set of high quality protein structures. No ad hoc scaling or correction factors are applied in the calculation of the curves. Two coarse-grained representations of protein structure were investigated; two scattering bodies per amino acid led to significantly better results than a single scattering body. Conclusion We show that the obtained point estimates allow the calculation of accurate SAXS curves from coarse-grained protein models. The resulting curves are on par with the current state-of-the-art program CRYSOL, which requires full atomic detail. Our method was also comparable to CRYSOL in recognizing native structures among native-like decoys. As a proof-of-concept, we combined the coarse-grained Debye calculation with a previously described probabilistic model of protein structure, TorusDBN. This resulted in a significant improvement in the decoy recognition performance. In conclusion, the presented method shows great promise for

  16. Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sedlak, Steffen M.; Bruetzel, Linda K.; Lipfert, Jan (LMU)

    2017-03-29

    A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ2(q) = [I(q) + const.]/(kq), whereI(q) is the scattering intensity as a function of the momentum transferq;kand const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurement errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.

  17. Structural evaluation of an amyloid fibril model using small-angle x-ray scattering

    Science.gov (United States)

    Dahal, Eshan; Choi, Mina; Alam, Nadia; Bhirde, Ashwinkumar A.; Beaucage, Serge L.; Badano, Aldo

    2017-08-01

    Amyloid fibrils are highly structured protein aggregates associated with a wide range of diseases including Alzheimer’s and Parkinson’s. We report a structural investigation of an amyloid fibril model prepared from a commonly used plasma protein (bovine serum albumin (BSA)) using small-angle x-ray scattering (SAXS) technique. As a reference, the size estimates from SAXS are compared to dynamic light scattering (DLS) data and the presence of amyloid-like fibrils is confirmed using Congo red absorbance assay. Our SAXS results consistently show the structural transformation of BSA from spheroid to rod-like elongated structures during the fibril formation process. We observe the elongation of fibrils over two months with fibril length growing from 35.9  ±  3.0 nm to 51.5  ±  2.1 nm. Structurally metastable fibrils with distinct SAXS profiles have been identified. As proof of concept, we demonstrate the use of such distinct SAXS profiles to detect fibrils in the mixture solutions of two species by estimating their volume fractions. This easily detectable and well-characterized amyloid fibril model from BSA can be readily used as a control or standard reference to further investigate SAXS applications in the detection of structurally diverse amyloid fibrils associated with protein aggregation diseases.

  18. Relaxation transition in glass-forming polybutadiene as revealed by nuclear resonance X-ray scattering.

    Science.gov (United States)

    Kanaya, Toshiji; Inoue, Rintaro; Saito, Makina; Seto, Makoto; Yoda, Yoshitaka

    2014-04-14

    We investigated the arrest mechanism of molecular motions in a glass forming polybutadiene near the glass transition using a new nuclear resonance synchrotron X-ray scattering technique to cover a wide time range (10(-9) to 10(-5) s) and a scattering vector Q range (9.6-40 nm(-1)), which have never been accessed by other methods. Owing to the wide time and Q ranges it was found for the first time that a transition of the α-process to the slow β-process (or the Johari-Goldstein process) was observed in a Q range higher than the first peak in the structure factor S(Q) at the critical temperature T(c) in the mode coupling theory. The results suggest the important roles of hopping motions below T(c), which was predicted by the recent extended mode coupling theory and the cooperative motions due to the strong correlation at the first peak in S(Q) in the arrest mechanism.

  19. Modeling detergent organization around aquaporin-0 using small-angle X-ray scattering.

    Science.gov (United States)

    Berthaud, Alice; Manzi, John; Pérez, Javier; Mangenot, Stéphanie

    2012-06-20

    Solubilization of integral membrane proteins in aqueous solutions requires the presence of amphiphilic molecules like detergents. The transmembrane region of the proteins is then surrounded by a corona formed by these molecules, ensuring a hydrophilic outer surface. The presence of this corona has strongly hampered structural studies of solubilized membrane proteins by small-angle X-ray scattering (SAXS), a technique frequently used to monitor conformational changes of soluble proteins. Through the online combination of size exclusion chromatography, SAXS, and refractometry, we have determined a precise geometrical model of the n-dodecyl β-d-maltopyranoside corona surrounding aquaporin-0, the most abundant membrane protein of the eye lens. The SAXS data were well-fitted by a detergent corona shaped in an elliptical toroid around the crystal structure of the protein, similar to the elliptical shape recently reported for nanodiscs (Skar-Gislinge et al. J. Am. Chem. Soc. 2010, 132, 13713-13722). The torus thickness determined from the curve-fitting protocol is in excellent agreement with the thickness of a lipid bilayer, while the number of detergent molecules deduced from the volume of the torus compares well with those obtained on the same sample from refractometry and mass analysis based on SAXS forward scattering. For the first time, the partial specific volume of the detergent surrounding a protein was measured. The present protocol is a crucial step toward future conformational studies of membrane proteins in solution.

  20. High-resolution x-ray scattering studies of charge ordering in highly correlated electron systems

    CERN Document Server

    Ghazi, M E

    2002-01-01

    addition, another very weak satellites with wavevector (1/2, 1, 1/2) were observed possibly due to spin ordering. two-dimensional in nature both by measurements of their correlation lengths and by measurement of the critical exponents of the charge stripe melting transition with an anomaly at x = 0.25. The results show by decreasing the hole concentration from the x = 0.33 to 0.2, the well-correlated charge stripes change to a glassy state at x = 0.25. The electronic transition into the charge stripe phase is second-order without any corresponding structural transition. Above the second-order transition critical scattering was observed due to fluctuations into the charge stripe phase. In a single-crystal of Nd sub 1 sub / sub 2 Sr sub 1 sub / sub 2 MnO sub 3 a series of phase transitions were observed using high-resolution synchrotron X-ray scattering. Above the charge ordering transition temperature, T sub C sub O , by measuring the peak profiles of Bragg reflections as a function of temperature, it was foun...

  1. Counterion Distribution Around Protein-SNAs probed by Small-angle X-ray scattering

    Science.gov (United States)

    Krishnamoorthy, Kurinji; Bedzyk, Michael; Kewalramani, Sumit; Moreau, Liane; Mirkin, Chad

    Protein-DNA conjugates couple the advanced cell transfection capabilities of spherical DNA architecture and the biocompatible enzymatic activity of a protein core to potentially create therapeutic agents with dual functionality. An understanding of their stabilizing ionic environment is crucial to better understand and predict their properties. Here, we use Small-angle X-ray scattering techniques to decipher the structure of the counterion cloud surrounding these DNA coated nanoparticles. Through the use of anomalous scattering techniques we have mapped the local concentrations of Rb+ ions in the region around the Protein-DNA constructs. These results are further corroborated with simulations using a geometric model for the excess charge density as function of radial distance from the protein core. Further, we investigate the influence of solution ionic strength on the structure of the DNA corona and demonstrate a reduction in the extension of the DNA corona with increasing concentration of NaCl in solution for the case of both single and double stranded DNA shells. Our work reveals the distribution of counterions in the vicinity of Protein-DNA conjugates and decouples the effect of solution ionic strength on the thickness of the DNA layer.

  2. Scanning of Adsorption Hysteresis In Situ with Small Angle X-Ray Scattering

    Science.gov (United States)

    Mitropoulos, Athanasios Ch.; Favvas, Evangelos P.; Stefanopoulos, Konstantinos L.; Vansant, Etienne F.

    2016-01-01

    Everett’s theorem-6 of the domain theory was examined by conducting adsorption in situ with small angle x-ray scattering (SAXS) supplemented by the contrast matching technique. The study focuses on the spectrum differences of a point to which the system arrives from different scanning paths. It is noted that according to this theorem at a common point the system has similar macroscopic properties. Furthermore it was examined the memory string of the system. We concluded that opposite to theorem-6: a) at a common point the system can reach in a finite (not an infinite) number of ways, b) a correction for the thickness of the adsorbed film prior to capillary condensation is necessary, and c) the scattering curves although at high-Q values coincide, at low-Q values are different indicating different microscopic states. That is, at a common point the system holds different metastable states sustained by hysteresis effects. These metastable states are the ones which highlight the way of a system back to a return point memory (RPM). Entering the hysteresis loop from different RPMs different histories are implanted to the paths toward the common point. Although in general the memory points refer to relaxation phenomena, they also constitute a characteristic feature of capillary condensation. Analogies of the no-passing rule and the adiabaticity assumption in the frame of adsorption hysteresis are discussed. PMID:27741263

  3. Studying nanostructure gradients in injection-molded polypropylene/montmorillonite composites by microbeam small-angle x-ray scattering

    DEFF Research Database (Denmark)

    Stribeck, Norbert; Schneider, Konrad; Zeinolebadi, Ahmad

    2014-01-01

    The core–shell structure in oriented cylindrical rods of polypropylene (PP) and nanoclay composites (NCs) from PP and montmorillonite (MMT) is studied by microbeam small-angle x-ray scattering (SAXS). The structure of neat PP is almost homogeneous across the rod showing regular semicrystalline...

  4. Studies of protein structure in solution and protein folding using synchrotron small-angle x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lingling [Stanford Univ., CA (United States)

    1996-04-01

    Synchrotron small angle x-ray scattering (SAXS) has been applied to the structural study of several biological systems, including the nitrogenase complex, the heat shock cognate protein (hsc70), and lysozyme folding. The structural information revealed from the SAXS experiments is complementary to information obtained by other physical and biochemical methods, and adds to our knowledge and understanding of these systems.

  5. Small-angle X-ray scattering: a high-throughput technique for investigating archaeological bone preservation

    NARCIS (Netherlands)

    Hiller, J.C.; Collins, M.J.; Chamberlain, A.T.; Wess, T.J.

    2004-01-01

    Diagenetic alteration to archaeological bone can cause significant disruption to both the biogenic mineral structure and the preservation of biomolecular resources such as protein and DNA over archaeological time. We report here the use of a technique, small-angle X-ray scattering, which makes it

  6. Self-assembly of designed coiled coil peptides studied by small-angle X-ray scattering and analytical ultracentrifugation

    DEFF Research Database (Denmark)

    Malik, Leila; Nygaard, Jesper; Christensen, Niels Johan

    2013-01-01

    , they are promising tools for the construction of nanomaterials. Small-angle X-ray scattering (SAXS) has emerged as a new biophysical technique for elucidation of protein topology. Here, we describe a systematic study of the self-assembly of a small ensemble of coiled coil sequences using SAXS and analytical...

  7. Femtosecond X-Ray Scattering Study of Ultrafast Photoinduced Structural Dynamics in Solvated [Co(terpy)2]2+

    DEFF Research Database (Denmark)

    Biasin, Elisa; Brandt van Driel, Tim; Kjær, Kasper Skov

    2016-01-01

    We study the structural dynamics of photoexcited [Co(terpy)2]2+ in an aqueous solution with ultrafast x-ray diffuse scattering experiments conducted at the Linac Coherent Light Source. Through direct comparisons with density functional theory calculations, our analysis shows...

  8. Structure and dynamics of polyelectrolyte complex coacervates studied by scattering of neutrons, X-rays, and light

    NARCIS (Netherlands)

    Spruijt, E.; Leermakers, F.A.M.; Fokkink, R.G.; Schweins, R.; Well, van A.A.; Cohen Stuart, M.A.; Gucht, van der J.

    2013-01-01

    We investigate the microscopic structure and density fluctuations of complex coacervates of flexible polyelectrolytes using scattering of neutrons, X-rays, and light. Poly(acrylic acid) and poly(N,N-dimethylaminoethyl methacrylate) offer a well-defined model system that allows for selective labeling

  9. X-ray and light scattering study of the structure of large protein aggregates at neutral pH

    NARCIS (Netherlands)

    Pouzot, M.; Nicolai, T.; Visschers, R.W.; Weijers, M.

    2005-01-01

    The structure of large ovalbumin and ß-lactoglobulin aggregates formed after heat-denaturation at neutral pH was studied using a combination of light and small-angle X-ray scattering. The effect of the electrostatic interactions was investigated by varying the ionic strength. The results were

  10. In-situ real-time x-ray scattering for probing the processing-structure-performance relation

    KAUST Repository

    Smilgies, Detlef-M.

    2014-01-01

    © 2014 Materials Research Society. In-situ X-ray scattering methodology is discussed, in order to analyze the microstructure development of soft functional materials during coating, annealing, and drying processes in real-time. The relevance of a fundamental understanding of coating processes for future industrial production is pointed out.

  11. Role of the Template in Model Biomineralization: Synchrotron X-ray Scattering Experiments

    Science.gov (United States)

    Uysal, Ahmet

    Synthesis of functional nanoparticles in cheap and environment friendly ways is one of the big challenges we face today. Interestingly, many biological systems are already expert at this task. Living organisms can grow nanocrystals of inorganic minerals with certain orientations and shapes and use them together with organic material to build structures with properties superior to the sum of their components. This process is called biomineralization. It has been previously shown that floating monolayers of amphiphilic molecules (Langmuir monolayers) can be used to simulate this process. This project covers the study of three different minerals, calcium oxalate, hydroxyapatite and gold, in an attempt to understand the role of the organic template in the model biomineralization experiments. We used in situ synchrotron x-ray scattering techniques to monitor the organic-inorganic interface during nucleation and growth of inorganic crystals. We also used scanning and transmission electron microscopy to study the structure of mature crystals ex situ . Although kidney stones (mostly calcium oxalate) are pathological in humans and animals, their microscopic structures exhibit considerable orientation and order, probably caused by organic molecules. Our x-ray scattering experiments revealed, first time, that in the early stages of the crystallization calcium oxalate crystals adapt a structure different from their known bulk structures. In the later stages, the crystals relax back to the bulk structure while changing the organization of the organic molecules next to them. We developed a model that explains these interactions in terms of the organic-inorganic interface potential energy. Hydroxyapatite is the main inorganic constituent of the vertebrate bone. In spite of the vast literature about bone mineralization, there is little known about the organic-inorganic interactions at the molecular level. In this thesis, we report the first in situ x-ray scattering experiments

  12. A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    De Caro, Liberato; Giannini, Cinzia; Bellotti, Roberto; Tangaro, Sabina [Istituto di Cristallografia-Consiglio Nazionale delle Ricerche (IC-CNR), via Amendola 122/O, I-70125 Bari, Italy and Istituto Nazionale Fisica Nucleare, Sezione di Bari, via Amendola 173, 70126 Bari (Italy); Istituto Nazionale Fisica Nucleare, Sezione di Bari, via Amendola 173, 70126 Bari, Italy and Dipartimento Interateneo di Fisica-M. Merlin, Universita degli Studi di Bari, via Amendola 173, 70126 Bari (Italy); Istituto Nazionale Fisica Nucleare, Sezione di Bari, via Amendola 173, 70126 Bari (Italy)

    2009-10-15

    Purpose: The x-ray transmitted beam from any material/tissue depends on the complex refractive index (n=1-{delta}+i{beta}), where {delta} is responsible for the phase shift and {beta} is for the beam attenuation. Although for human tissues, the {delta} cross section is about 1000 times greater than the {beta} ones in the x-ray energy range from 10 to 150 keV, the gain in breast tumor visualization of phase-contrast mammography (PCM) with respect to absorption contact imaging (AI) is limited by the maximum dose that can be delivered to the patient. Moreover, in-line PC imaging (PCI) is the simplest experimental mode among all available x-ray PCI techniques since no optics are needed. The latter is a fundamental requirement in order to transfer the results of laboratory research into hospitals. Alternative to synchrotron radiation sources, the implementation of relativistic Thomson-scattering (TS) x-ray sources is particularly suitable for hospital use because of their high peak brightness within a relatively compact and affordable system. In this work, the possibility to realize PCM using a TS source in a hospital environment is studied, accounting for the effect of a finite deliverable dose on the PC visibility enhancement with respect to AI. Methods: The contrast-to-noise ratio of tumor-tissue lesions in PCM has been studied on the bases of a recent theoretical model, describing image contrast formation by means of both wave-optical theory and the mutual coherence formalism. The latter is used to describe the evolution, during wave propagation, of the coherence of the wave field emitted by a TS source. The contrast-to-noise ratio for both PCI and AI has been analyzed in terms of tumor size, beam energy, detector, and source distances, studying optimal conditions for performing PCM. Regarding other relevant factors which could influence ''tumor'' visibility, the authors have assumed simplified conditions such as a spherical shape description of

  13. Geant4 simulations of soft proton scattering in X-ray optics. A tentative validation using laboratory measurements

    Science.gov (United States)

    Fioretti, Valentina; Mineo, Teresa; Bulgarelli, Andrea; Dondero, Paolo; Ivanchenko, Vladimir; Lei, Fan; Lotti, Simone; Macculi, Claudio; Mantero, Alfonso

    2017-12-01

    Low energy protons (X-ray telescopes, scatter on their mirror surfaces at small incident angles, and deposit energy on the detector. This phenomenon can cause intense background flares at the focal plane decreasing the mission observing time (e.g. the XMM-Newton mission) or in the most extreme cases, damaging the X-ray detector. A correct modelization of the physics process responsible for the grazing angle scattering processes is mandatory to evaluate the impact of such events on the performance (e.g. observation time, sensitivity) of future X-ray telescopes as the ESA ATHENA mission. The Remizovich model describes particles reflected by solids at glancing angles in terms of the Boltzmann transport equation using the diffuse approximation and the model of continuous slowing down in energy. For the first time this solution, in the approximation of no energy losses, is implemented, verified, and qualitatively validated on top of the Geant4 release 10.2, with the possibility to add a constant energy loss to each interaction. This implementation is verified by comparing the simulated proton distribution to both the theoretical probability distribution and with independent ray-tracing simulations. Both the new scattering physics and the Coulomb scattering already built in the official Geant4 distribution are used to reproduce the latest experimental results on grazing angle proton scattering. At 250 keV multiple scattering delivers large proton angles and it is not consistent with the observation. Among the tested models, the single scattering seems to better reproduce the scattering efficiency at the three energies but energy loss obtained at small scattering angles is significantly lower than the experimental values. In general, the energy losses obtained in the experiment are higher than what obtained by the simulation. The experimental data are not completely representative of the soft proton scattering experienced by current X-ray telescopes because of the lack of

  14. Resonant Inelastic X-ray Scattering of Rare-Earth and CopperSystems

    Energy Technology Data Exchange (ETDEWEB)

    Kvashnina, Kristina [Uppsala Univ. (Sweden)

    2007-07-11

    Rare earths and copper systems were studied using X-ray absorption spectroscopy (XAS) and resonant inelastic X-ray scattering (RIXS). The use of monochromased synchotron radiation and improved energy resolution for RIXS made possible to obtain valuable information on the electronic structure in 4f, 5f and 3d systems. Experimental results for rare-earths (Ho, Gd, Cm, U, Np, Pu) were analyzed by atomic multiplet theory based on the Hartree-Fock calculations. The inelastic scattering structures in RIXS spectra at 5d edge of actinides found to be sensitive to actinide oxidation states in different systems. Comparison of experimental and calculated Cm 5d RIXS spectra gave direct information about valency of the 248-curium isotope in oxide. Scientific understanding of processes that control chemical changes of radioactive species from spent fuel is improved by studying interactions of actinide ions (U, Np, Pu) with corroded iron surfaces. RIXS measurements at the actinide 5d edge found to be sensitive to actinide oxidation states in different systems. Comparison of experimental and calculated Cm 5d RIXS spectra gave direct information about valency of the 248 curium isotope in oxide. Scientific understanding of processes that control chemical changes of radioactive species from spent fuel is improved by studying interactions of actinide ions (U, Np, Pu) with corroded iron surfaces. RIXS measurements at the actinide 5d edge indicate the reduction of U(VI), NP(V) and Pu(VI) to U(IV), Np(IV) and Pu(IV) by presence of iron ions. This thesis is also addressed to the study of changes in the electronic structure of copper films during interaction with synthetic groundwater solutions. The surface modifications induced by chemical reactions of oxidized 100 Angstrom Cu films with CL-, SO42- and HCO3- ions in aqueous solutions with various concentrations were studied in-situ using XAS. It was shown that the pH value, the

  15. Size And Shape of Detergent Micelles Determined By Small-Angle X-Ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Lipfert, Jan; Columbus, Linda; Chu, Vincent B.; Lesley, Scott A.; Doniach, Sebastian; /Stanford U., Phys. Dept. /Stanford U., Appl. Phys. Dept. /SLAC, SSRL /Pasteur Inst., Paris /Scripps Res. Inst. /Novartis Res. Found.

    2009-04-29

    We present a systematic analysis of the aggregation number and shape of micelles formed by nine detergents commonly used in the study of membrane proteins. Small-angle X-ray scattering measurements are reported for glucosides with 8 and 9 alkyl carbons (OG/NG), maltosides and phosphocholines with 10 and 12 alkyl carbons (DM/DDM and FC-10/FC-12), 1,2-dihexanoyl-sn-glycero-phosphocholine (DHPC), 1-palmitoyl-2-hydroxy-sn-glycero-3-[phospho-rac-(1-glycerol)] (LPPG), and 3-[(3-cholamidopropyl)dimethylammonio]-1-propane sulfonate (CHAPS). The SAXS intensities are well described by two-component ellipsoid models, with a dense outer shell corresponding to the detergent head groups and a less electron dense hydrophobic core. These models provide an intermediate resolution view of micelle size and shape. In addition, we show that Guinier analysis of the forward scattering intensity can be used to obtain an independent and model-free measurement of the micelle aggregation number and radius of gyration. This approach has the advantage of being easily generalizable to protein-detergent complexes, where simple geometric models are inapplicable. Furthermore, we have discovered that the position of the second maximum in the scattering intensity provides a direct measurement of the characteristic head group-head group spacing across the micelle core. Our results for the micellar aggregation numbers and dimensions agree favorably with literature values as far as they are available. We de novo determine the shape of FC-10, FC-12, DM, LPPG, and CHAPS micelles and the aggregation numbers of FC-10 and OG to be ca. 50 and 250, respectively. Combined, these data provide a comprehensive view of the determinants of micelle formation and serve as a starting point to correlate detergent properties with detergent-protein interactions.

  16. Refraction and ultra-small-angle scattering of X-rays in a single-crystal diamond compound refractive lens.

    Science.gov (United States)

    Gasilov, S; Mittone, A; Dos Santos Rolo, T; Polyakov, S; Zholudev, S; Terentyev, S; Blank, V; Bravin, A; Baumbach, T

    2017-11-01

    In this work a double-crystal setup is employed to study compound refractive lenses made of single-crystal diamond. The point spread function of the lens is calculated taking into account the lens transmission, the wavefront aberrations, and the ultra-small-angle broadening of the X-ray beam. It is shown that, similarly to the wavefront aberrations, the ultra-small-angle scattering effects can significantly reduce the intensity gain and increase the focal spot size. The suggested approach can be particularly useful for the characterization of refractive X-ray lenses composed of many tens of unit lenses.

  17. Visualizing a protein quake with time-resolved X-ray scattering at a free-electron laser

    DEFF Research Database (Denmark)

    Arnlund, David; Johansson, Linda C.; Wickstrand, Cecilia

    2014-01-01

    We describe a method to measure ultrafast protein structural changes using time-resolved wide-angle X-ray scattering at an X-ray free-electron laser. We demonstrated this approach using multiphoton excitation of the Blastochloris viridis photosynthetic reaction center, observing an ultrafast global...... conformational change that arises within picoseconds and precedes the propagation of heat through the protein. This provides direct structural evidence for a 'protein quake': the hypothesis that proteins rapidly dissipate energy through quake-like structural motions....

  18. Ordering phenomena in FeCo-films and Fe/Cr-multilayers: an X-ray and neutron scattering study

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, B.

    2001-07-01

    The following topics are covered: critical phenomena in thin films, critical adsorption, finite size scaling, FeCo Ising model, kinematical scattering theory for thin films, FeCo thin films, growth and characterisation of single crystal FeCo thin films, X-ray study of ordering in FeCo films, antiferromagnetic coupling in Fe/Cr multilayers, neutron scattering on Fe/Cr multilayers (WL)

  19. X-Ray and Neutron Scattering Study of the Magnetic Structure of Neodymium Metal

    DEFF Research Database (Denmark)

    Lebech, Bente; Als-Nielsen, Jens Aage; McEwen, K. A.

    1979-01-01

    A combined x-ray and neutron diffraction study has shown that the so-called "triple-q⃗" structure is not the correct model of the magnetic structure of neodymium. The x-ray data showed only the Bragg reflections originating from the double-hcp lattice. Hence, all additional reflections observed...

  20. Antiferroelectric surface layers in a liquid crystal as observed by synchrotron x-ray scattering

    DEFF Research Database (Denmark)

    Gramsbergen, E. F.; de Jeu, W. H.; Als-Nielsen, Jens Aage

    1986-01-01

    The X-ray reflectivity form the surface of a liquid crystal with terminally polar (cyano substituted) molecules has been studied using a high-resolution triple-axis X-ray spectrometer in combination with a synchrotron source. It is demonstrated that at the surface of the smectic Al phase a few...

  1. Resonant soft x-ray scattering from stepped surfaces of SrTiO3

    NARCIS (Netherlands)

    Schlappa, J.; Chang, C.F.; Hu, Z.; Schierle, E.; Ott, H.; Weschke, E.; Kaindl, G.; Huijben, Mark; Rijnders, Augustinus J.H.M.; Blank, David H.A.; Tjeng, L.H.; Schüssler-Langeheine, C.

    2012-01-01

    We studied the resonant diffraction signal from stepped surfaces of SrTiO3 at the Ti 2p ¿ 3d (L2,3) resonance in comparison with x-ray absorption (XAS) and specular reflectivity data. The steps on the surface form an artificial superstructure suitable as a model system for resonant soft x-ray

  2. Operando Grazing Incidence Small-Angle X-ray Scattering/X-ray Diffraction of Model Ordered Mesoporous Lithium-Ion Battery Anodes.

    Science.gov (United States)

    Bhaway, Sarang M; Qiang, Zhe; Xia, Yanfeng; Xia, Xuhui; Lee, Byeongdu; Yager, Kevin G; Zhang, Lihua; Kisslinger, Kim; Chen, Yu-Ming; Liu, Kewei; Zhu, Yu; Vogt, Bryan D

    2017-02-28

    Emergent lithium-ion (Li+) batteries commonly rely on nanostructuring of the active electrode materials to decrease the Li+ ion diffusion path length and to accommodate the strains associated with the insertion and de-insertion of Li+, but in many cases these nanostructures evolve during electrochemical charging-discharging. This change in the nanostructure can adversely impact performance, and challenges remain regarding how to control these changes from the perspective of morphological design. In order to address these questions, operando grazing-incidence small-angle X-ray scattering and X-ray diffraction (GISAXS/GIXD) were used to assess the structural evolution of a family of model ordered mesoporous NiCo2O4 anode films during battery operation. The pore dimensions were systematically varied and appear to impact the stability of the ordered nanostructure during the cycling. For the anodes with small mesopores (≈9 nm), the ordered nanostructure collapses during the first two charge-discharge cycles, as determined from GISAXS. This collapse is accompanied by irreversible Li-ion insertion within the oxide framework, determined from GIXD and irreversible capacity loss. Conversely, anodes with larger ordered mesopores (17-28 nm) mostly maintained their nanostructure through the first two cycles with reversible Li-ion insertion. During the second cycle, there was a small additional deformation of the mesostructure. This preservation of the ordered structure lead to significant improvement in capacity retention during these first two cycles; however, a gradual loss in the ordered nanostructure from continuing deformation of the ordered structure during additional charge-discharge cycles leads to capacity decay in battery performance. These multiscale operando measurements provide insight into how changes at the atomic scale (lithium insertion and de-insertion) are translated to the nanostructure during battery operation. Moreover, small changes in the nanostructure

  3. High-resolution soft X-ray beamline ADRESS at the Swiss Light Source for resonant inelastic X-ray scattering and angle-resolved photoelectron spectroscopies

    Science.gov (United States)

    Strocov, V. N.; Schmitt, T.; Flechsig, U.; Schmidt, T.; Imhof, A.; Chen, Q.; Raabe, J.; Betemps, R.; Zimoch, D.; Krempasky, J.; Wang, X.; Grioni, M.; Piazzalunga, A.; Patthey, L.

    2010-01-01

    The concepts and technical realisation of the high-resolution soft X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for resonant inelastic X-ray scattering (RIXS) and angle-resolved photoelectron spectroscopy (ARPES) are described. The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not only the light polarization (including circular and 0–180° rotatable linear polarizations) but also the energy without changing the gap. The beamline optics is based on the well established scheme of plane-grating monochromator operating in collimated light. The ultimate resolving power E/ΔE is above 33000 at 1 keV photon energy. The choice of blazed versus lamellar gratings and optimization of their profile parameters is described. Owing to glancing angles on the mirrors as well as optimized groove densities and profiles of the gratings, the beamline is capable of delivering high photon flux up to 1 × 1013 photons s−1 (0.01% BW)−1 at 1 keV. Ellipsoidal refocusing optics used for the RIXS endstation demagnifies the vertical spot size down to 4 µm, which allows slitless operation and thus maximal transmission of the high-resolution RIXS spectrometer delivering E/ΔE > 11000 at 1 keV photon energy. Apart from the beamline optics, an overview of the control system is given, the diagnostics and software tools are described, and strategies used for the optical alignment are discussed. An introduction to the concepts and instrumental realisation of the ARPES and RIXS endstations is given. PMID:20724785

  4. Time-resolved X-ray scattering by electronic wave packets: analytic solutions to the hydrogen atom

    DEFF Research Database (Denmark)

    Simmermacher, Mats; Henriksen, Niels Engholm; Møller, Klaus Braagaard

    2017-01-01

    description of time-resolved X-ray scattering by non-stationary electronic wave packets in atomic systems. A consistent application of the Waller-Hartree approximation is discussed and different contributions to the total differential scattering signal are identified and interpreted. Moreover......, it is demonstrated how the scattering signal of wave packets in the hydrogen atom can be expressed analytically. This permits simulations without numerical integration and establishes a benchmark for both efficiency and accuracy. Based on that, scattering patterns of an exemplary wave packet in the hydrogen atom...

  5. A Platform for X-Ray Thomson Scattering Measurements of Radiation Hydrodynamics Experiments on the NIF

    Science.gov (United States)

    Lefevre, Heath; Ma, Kevin; Belancourt, Patrick; MacDonald, Michael; Doeppner, Tilo; Keiter, Paul; Kuranz, Carolyn

    2017-10-01

    A recent experiment on the National Ignition Facility (NIF) radiographed the evolution of the Rayleigh-Taylor (RT) instability under high and low drive cases. This experiment showed that under a high drive the growth rate of the RT instability is reduced relative to the low drive case. The high drive launches a radiative shock, increases the temperature of the post-shock region, and ablates the spikes, which reduces the RT growth rate. The plasma parameters must be measured to validate this claim. We present a target design for making X-Ray Thomson Scattering (XRTS) measurements on radiation hydrodynamics experiments on NIF to measure the electron temperature of the shocked region in the above cases. Specifically, we show that a previously fielded NIF radiation hydrodynamics platform can be modified to allow sufficient signal and temperature resolution for XRTS measurements. This work is funded by the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, Grant Number DE-NA0002956 and the National Science Foundation through the Basic Plasma Science and Engineering program.

  6. Topological investigation of electronic silicon nanoparticulate aggregates using ultra-small-angle X-ray scattering

    Science.gov (United States)

    Jonah, E. O.; Britton, D. T.; Beaucage, P.; Rai, D. K.; Beaucage, G.; Magunje, B.; Ilavsky, J.; Scriba, M. R.; Härting, M.

    2012-11-01

    The network topology of two types of silicon nanoparticles, produced by high energy milling and pyrolysis of silane, in layers deposited from inks on permeable and impermeable substrates has been quantitatively characterized using ultra-small-angle X-ray scattering, supported by scanning electron microscopy observations. The milled particles with a highly polydisperse size distribution form agglomerates, which in turn cluster to form larger aggregates with a very high degree of aggregation. Smaller nanoparticles with less polydisperse size distribution synthesized by thermal catalytic pyrolysis of silane form small open clusters. The Sauter mean diameters of the primary particles of the two types of nanoparticles were obtained from USAXS particle volume to surface ratio, with values of 41 and 21 nm obtained for the high energy milled and pyrolysis samples, respectively. Assuming a log-normal distribution of the particles, the geometric standard deviation of the particles was calculated to be 1.48 for all the samples, using parameters derived from the unified fit to the USAXS data. The flow properties of the inks and substrate combination lead to quantitative changes in the mean particle separation, with slowly curing systems with good capillary flow resulting in denser networks with smaller aggregates and better contact between particles.

  7. Nanoconfinement platform for nanostructure quantification via grazing-transmission X-ray scattering

    Science.gov (United States)

    Black, Charles T.; Yager, Kevin G.

    2017-01-31

    A nano-confinement platform that may allow improved quantification of the structural order of nanometer-scale systems. Sample-holder `chips` are designed for the GTSAXS experimental geometry. The platform involves fabricated nanostructured sample holders on and in one or more corners of a substrate support where the sample material of interest is positioned at the corner of the substrate support. In an embodiment, the substrate material making up the substrate support beneath the sample-holding area is removed. A scattering x-ray sample platform includes a substrate support arranged in a parallelepiped form, having a substantially flat base and a substantially flat top surface, the top surface being substantially parallel with the base, the parallelepiped having a plurality of corners. At least one corner of the substrate support has a sample holding area formed in the top surface of the substrate support and within a predetermined distance from the corner. The sample holding area includes a regular array of nano-wells formed in the top surface of the substrate support.

  8. Structure parameters of synaptic vesicles quantified by small-angle x-ray scattering.

    Science.gov (United States)

    Castorph, Simon; Riedel, Dietmar; Arleth, Lise; Sztucki, Michael; Jahn, Reinhard; Holt, Matthew; Salditt, Tim

    2010-04-07

    Synaptic vesicles (SVs) are small, membrane-bound organelles that are found in the synaptic terminal of neurons, and which are crucial in neurotransmission. After a rise in internal [Ca(2+)] during neuronal stimulation, SVs fuse with the plasma membrane releasing their neurotransmitter content, which then signals neighboring neurons. SVs are subsequently recycled and refilled with neurotransmitter for further rounds of release. Recently, tremendous progress has been made in elucidating the molecular composition of SVs, as well as putative protein-protein interactions. However, what is lacking is an empirical description of SV structure at the supramolecular level-which is necessary to enable us to fully understand the processes of membrane fusion, retrieval, and recycling. Using small-angle x-ray scattering, we have directly investigated the size and structure of purified SVs. From this information, we deduced detailed size and density parameters for the protein layers responsible for SV function, as well as information about the lipid bilayer. To achieve a convincing model fit, a laterally anisotropic structure for the protein shell is needed, as a rotationally symmetric density profile does not explain the data. Not only does our model confirm many of the preexisting ideas concerning SV structure, but also for the first time, to our knowledge, it indicates structural refinements, such as the presence of protein microdomains. Copyright (c) 2010 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  9. Automated acquisition and analysis of small angle X-ray scattering data

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Daniel, E-mail: d.franke@embl-hamburg.de [European Molecular Biology Laboratory, Hamburg Outstation Notkestrasse 85, D22603 Hamburg (Germany); Kikhney, Alexey G., E-mail: a.kikhney@embl-hamburg.de [European Molecular Biology Laboratory, Hamburg Outstation Notkestrasse 85, D22603 Hamburg (Germany); Svergun, Dmitri I., E-mail: d.svergun@embl-hamburg.de [European Molecular Biology Laboratory, Hamburg Outstation Notkestrasse 85, D22603 Hamburg (Germany)

    2012-10-11

    Small Angle X-ray Scattering (SAXS) is a powerful tool in the study of biological macromolecules providing information about the shape, conformation, assembly and folding states in solution. Recent advances in robotic fluid handling make it possible to perform automated high throughput experiments including fast screening of solution conditions, measurement of structural responses to ligand binding, changes in temperature or chemical modifications. Here, an approach to full automation of SAXS data acquisition and data analysis is presented, which advances automated experiments to the level of a routine tool suitable for large scale structural studies. The approach links automated sample loading, primary data reduction and further processing, facilitating queuing of multiple samples for subsequent measurement and analysis and providing means of remote experiment control. The system was implemented and comprehensively tested in user operation at the BioSAXS beamlines X33 and P12 of EMBL at the DORIS and PETRA storage rings of DESY, Hamburg, respectively, but is also easily applicable to other SAXS stations due to its modular design.

  10. Structure Parameters of Synaptic Vesicles Quantified by Small-Angle X-Ray Scattering

    Science.gov (United States)

    Castorph, Simon; Riedel, Dietmar; Arleth, Lise; Sztucki, Michael; Jahn, Reinhard; Holt, Matthew; Salditt, Tim

    2010-01-01

    Synaptic vesicles (SVs) are small, membrane-bound organelles that are found in the synaptic terminal of neurons, and which are crucial in neurotransmission. After a rise in internal [Ca2+] during neuronal stimulation, SVs fuse with the plasma membrane releasing their neurotransmitter content, which then signals neighboring neurons. SVs are subsequently recycled and refilled with neurotransmitter for further rounds of release. Recently, tremendous progress has been made in elucidating the molecular composition of SVs, as well as putative protein-protein interactions. However, what is lacking is an empirical description of SV structure at the supramolecular level—which is necessary to enable us to fully understand the processes of membrane fusion, retrieval, and recycling. Using small-angle x-ray scattering, we have directly investigated the size and structure of purified SVs. From this information, we deduced detailed size and density parameters for the protein layers responsible for SV function, as well as information about the lipid bilayer. To achieve a convincing model fit, a laterally anisotropic structure for the protein shell is needed, as a rotationally symmetric density profile does not explain the data. Not only does our model confirm many of the preexisting ideas concerning SV structure, but also for the first time, to our knowledge, it indicates structural refinements, such as the presence of protein microdomains. PMID:20371319

  11. Synchrotron small-angle X-ray scattering studies of hemoglobin nonaggregation confined inside polymer capsules.

    Science.gov (United States)

    Mandal, Soumit S; Bhaduri, Satarupa; Amenitsch, Heinz; Bhattacharyya, Aninda J

    2012-08-16

    The effect of confinement on the structure of hemoglobin (Hb) within polymer capsules was investigated here. Hemoglobin transformed from an aggregated state in solution to a nonaggregated state when confined inside the polymer capsules. This was directly confirmed using synchrotron small-angle X-ray scattering (SAXS) studies. The radius of gyration (R(g)) and polydispersity (p) of the proteins in the confined state were smaller compared to those in solution. In fact, the R(g) value is very similar to theoretical values obtained using protein structures generated from the Protein Databank. In the temperature range (25-85 °C, Tm 59 °C), the R(g) values for the confined Hb remained constant. This observation is in contrary to the increasing R(g) values obtained for the bare Hb in solution. This suggested higher thermal stability of Hb when confined inside the polymer capsule than when in solution. Changes in protein configuration were also reflected in the protein function. Confinement resulted in a beneficial enhancement of the electroactivity of Hb. While Hb in solution showed dominance of the cathodic process (Fe(3+) → Fe(2+)), efficient reversible Fe(3+)/Fe(2+) redox response is observed in the case of the confined Hb. This has important protein functional implications. Confinement allows the electroactive heme to take up positions favorable for various biochemical activities such as sensing of analytes of various sizes from small to macromolecules and controlled delivery of drugs.

  12. Collagen Orientation and Crystallite Size in Human Dentin: A Small Angle X-ray Scattering Study

    Energy Technology Data Exchange (ETDEWEB)

    Pople, John A

    2001-03-29

    The mechanical properties of dentin are largely determined by the intertubular dentin matrix, which is a complex composite of type I collagen fibers and a carbonate-rich apatite mineral phase. The authors perform a small angle x-ray scattering (SAXS) study on fully mineralized human dentin to quantify this fiber/mineral composite architecture from the nanoscopic through continuum length scales. The SAXS results were consistent with nucleation and growth of the apatite phase within periodic gaps in the collagen fibers. These mineralized fibers were perpendicular to the dentinal tubules and parallel with the mineralization growth front. Within the plane of the mineralization front, the mineralized collagen fibers were isotropic near the pulp, but became mildly anisotropic in the mid-dentin. Analysis of the data also indicated that near the pulp the mineral crystallites were approximately needle-like, and progressed to a more plate-like shape near the dentino-enamel junction. The thickness of these crystallites, {approx} 5 nm, did not vary significantly with position in the tooth. These results were considered within the context of dentinogenesis and maturation.

  13. In situ X-ray Scattering and Dynamical Modeling of Pd Catalyst Nanoparticles Formed in Flames

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Juan; Seifert, Sönke; Winans, Randall E.; Tolmachoff, Erik; Xin, Yuxuan; Chen, Dongping; Wang, Hai; Anderson, Scott L.

    2015-08-20

    It has previously been demonstrated that organopalladium precursors can break down under combustion conditions, forming nanoparticles that catalyze ignition. Here, we use in situ small-angle X-ray scattering (SAXS) to probe the formation and growth of palladium nanoparticles in an ethylene fl ame doped with 28 ppm (mol) of Pd(acetate) 2 . The particles appear to nucleate in the fl ame front and are observed by SAXS to grow in size and mass in the high-temperature region of the fl ame ( ~ 2200 K) with median diameters that evolve from 1.5 to 3.0 nm. Transmission electron microscopy of particles collected on a grid located outside the fl ame shows that the particles are metallic palladium with sizes comparable to those determined by SAXS. Molecular dynamics simulation of particles of selected sizes indicates that at the fl ame temperature the particles are molten and the average mass density of the particle material is notably smaller than that of bulk, liquid Pd at the melting point. Both experimental and computational results point to homogeneous nucleation and particle - particle coalescence as mechanisms for particle formation and growth. Aerosol dynamics simulation reproduces the time evolution of the particle size distribution and suggests that a substantial fraction of the particles must be electrically charged during their growth process.

  14. Theoretical approach to direct resonant inelastic X-ray scattering on magnets and superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Marra, Pasquale

    2015-10-26

    The capability to probe the dispersion of elementary spin, charge, orbital, and lattice excitations has positioned resonant inelastic X-ray scattering (RIXS) at the forefront of photon science. In this work, we will investigate how RIXS can contribute to a deeper understanding of the orbital properties and of the pairing mechanism in unconventional high-temperature superconductors. In particular, we show how direct RIXS spectra of magnetic excitations can reveal long-range orbital correlations in transition metal compounds, by discriminating different kind of orbital order in magnetic and antiferromagnetic systems. Moreover, we show how RIXS spectra of quasiparticle excitations in superconductors can measure the superconducting gap magnitude, and reveal the presence of nodal points and phase differences of the superconducting order parameter on the Fermi surface. This can reveal the properties of the underlying pairing mechanism in unconventional superconductors, in particular cuprates and iron pnictides, discriminating between different superconducting order parameter symmetries, such as s,d (singlet pairing) and p wave (triplet pairing).

  15. Analysis and implementation of a space resolving spherical crystal spectrometer for x-ray Thomson scattering experiments.

    Science.gov (United States)

    Harding, E C; Ao, T; Bailey, J E; Loisel, G; Sinars, D B; Geissel, M; Rochau, G A; Smith, I C

    2015-04-01

    The application of a space-resolving spectrometer to X-ray Thomson Scattering (XRTS) experiments has the potential to advance the study of warm dense matter. This has motivated the design of a spherical crystal spectrometer, which is a doubly focusing geometry with an overall high sensitivity and the capability of providing high-resolution, space-resolved spectra. A detailed analysis of the image fluence and crystal throughput in this geometry is carried out and analytical estimates of these quantities are presented. This analysis informed the design of a new spectrometer intended for future XRTS experiments on the Z-machine. The new spectrometer collects 6 keV x-rays with a spherically bent Ge (422) crystal and focuses the collected x-rays onto the Rowland circle. The spectrometer was built and then tested with a foam target. The resulting high-quality spectra prove that a spherical spectrometer is a viable diagnostic for XRTS experiments.

  16. Resonant inelastic X-ray scattering as a probe of molecular structure and electron dynamics in solutions

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Kathrin M. [Joint Ultrafast Dynamics Lab in Solutions and at Interfaces (JULiq), Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany); Freie Universität Berlin, FB Physik, Arnimallee 14, D-14195 Berlin (Germany); Max-Born-Institut, Max Born Straße 2A, 12489 Berlin (Germany); Suljoti, Edlira [Joint Ultrafast Dynamics Lab in Solutions and at Interfaces (JULiq), Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany); Freie Universität Berlin, FB Physik, Arnimallee 14, D-14195 Berlin (Germany); Aziz, Emad F., E-mail: Emad.Aziz@fu-berlin.de [Joint Ultrafast Dynamics Lab in Solutions and at Interfaces (JULiq), Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany); Freie Universität Berlin, FB Physik, Arnimallee 14, D-14195 Berlin (Germany)

    2013-06-15

    Resonant inelastic X-ray scattering (RIXS) technique is applied to gain insight into the local electronic structure in liquid phase. The approach combines a liquid micro-jet and an X-ray emission spectrometer (XES) both installed in the recently developed LiXEdrom experimental station. Here we demonstrate how the combined approach enables investigation of the hydrogen bonding network in water and of chemical bonding in different solvents. In addition, the probe of energy transfer and electron dynamics at the metal–solvent interface is achieved by comparing the integrated RIXS intensities of the different radiative decay channels of the 2p core-hole of 3d transition-metals. The integrated RIXS intensities build the partial and the inverse partial X-ray fluorescence yields that allow for absorption measurements free from background signal of other elements or saturation effects.

  17. Combining THz laser excitation with resonant soft X-ray scattering at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Joshua J., E-mail: joshuat@slac.stanford.edu; Dakovski, Georgi L.; Hoffmann, Matthias C. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Hwang, Harold Y. [Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Zarem, Alex; Schlotter, William F.; Moeller, Stefan; Minitti, Michael P. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Staub, Urs [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland); Johnson, Steven [ETH Zurich, Institute for Quantum Electronics, Wolfgang-Pauli-Strasse 16, 8093 Zurich (Switzerland); Mitra, Ankush; Swiggers, Michele; Noonan, Peter; Curiel, G. Ivan; Holmes, Michael [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-11

    This paper describes new instrumentation developments at the LCLS for materials studies using THz laser excitation and resonant soft X-ray scattering. This paper describes the development of new instrumentation at the Linac Coherent Light Source for conducting THz excitation experiments in an ultra high vacuum environment probed by soft X-ray diffraction. This consists of a cantilevered, fully motorized mirror system which can provide 600 kV cm{sup −1} electric field strengths across the sample and an X-ray detector that can span the full Ewald sphere with in-vacuum motion. The scientific applications motivated by this development, the details of the instrument, and spectra demonstrating the field strengths achieved using this newly developed system are discussed.

  18. Diagnostics for the optimization of an 11 keV inverse Compton scattering x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Chauchat, A.-S.; Brasile, J.-P [Thales Communications and Security, 4 avenue des Louvresses 92230 Gennevilliers (France); Le Flanchec, V.; Negre, J.-P.; Binet, A. [CEA DAM DIF, Bruyeres-le-Chatel 91290 Arpajon (France); Ortega, J.-M. [LCP Universite Paris-Sud, Bat. 201, 91405 Orsay (France)

    2013-04-19

    In a scope of a collaboration between Thales Communications and Security and CEA DAM DIF, 11 keV Xrays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 {mu}m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.

  19. Beyond simple small-angle X-ray scattering: developments in online complementary techniques and sample environments

    Directory of Open Access Journals (Sweden)

    Wim Bras

    2014-11-01

    Full Text Available Small- and wide-angle X-ray scattering (SAXS, WAXS are standard tools in materials research. The simultaneous measurement of SAXS and WAXS data in time-resolved studies has gained popularity due to the complementary information obtained. Furthermore, the combination of these data with non X-ray based techniques, via either simultaneous or independent measurements, has advanced understanding of the driving forces that lead to the structures and morphologies of materials, which in turn give rise to their properties. The simultaneous measurement of different data regimes and types, using either X-rays or neutrons, and the desire to control parameters that initiate and control structural changes have led to greater demands on sample environments. Examples of developments in technique combinations and sample environment design are discussed, together with a brief speculation about promising future developments.

  20. SU-E-I-44: Some Preliminary Analysis of Angular Distribution of X-Ray Scattered On Soft Tissues

    Energy Technology Data Exchange (ETDEWEB)

    Ganezer, K; Krmar, M; Cvejic, Z; Rakic, S; Pajic, B [University of Novi Sad, Novi Sad Serbia (Serbia)

    2015-06-15

    Purpose: The angular distribution of x-radiation scattered at small angles (up to 16 degrees) from several different animal soft tissue (skin, fat, muscle, retina, etc) were measured using standard equipment devoted to study of crystal structure which provides excellent geometry conditions of measurements. showed measurable differences for different tissues. In the simplest possible case when measured samples do not differ in structure (different concentration solutions) it can be seen that intensity of scattered radiation is decreasing function of the concentration and the peak of the maximum of scattering distribution depends on the concentration as well. Methods: An x-ray scattering profile usually consists of sharp diffraction peak; however some properties of the spatial profiles of scattered radiation as intensity, the peak position, height, area, FWHM, the ratio of peak heights, etc. Results: The data contained measurable differences for different tissues. In the simplest possible case when measured samples do not differ in structure (different concentration solutions) it can be seen that intensity of scattered radiation is decreasing function of the concentration and the peak of the maximum of scattering distribution depends on the concentration as well. Measurements of different samples in the very preliminary phase showed that simple biological material used in study showed slightly different scattering pattern, especially at higher angles (around 10degrees). Intensity of radiation scattered from same tissue type is very dependent on water content and several more parameters. Conclusion: This preliminary study using animal soft tissues on the angular distributions of scattered x-rays suggests that angular distributions of X-rays scattered off of soft tissues might be useful in distinguishing healthy tissue from malignant soft tissue.

  1. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic.

    Science.gov (United States)

    Swadling, G F; Ross, J S; Datte, P; Moody, J; Divol, L; Jones, O; Landen, O

    2016-11-01

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause "blanking" (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm -2 . This is significantly above the expected threshold for the onset of "blanking" effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate "blanking." Estimates suggest that an areal density of 10 19 cm -2 Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  2. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Swadling, G. F.; Ross, J. S.; Datte, P.; Moody, J.; Divol, L.; Jones, O.; Landen, O. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-11-15

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause “blanking” (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm{sup −2}. This is significantly above the expected threshold for the onset of “blanking” effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate “blanking.” Estimates suggest that an areal density of 10{sup 19} cm{sup −2} Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  3. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

    Science.gov (United States)

    Swadling, G. F.; Ross, J. S.; Datte, P.; Moody, J.; Divol, L.; Jones, O.; Landen, O.

    2016-11-01

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause "blanking" (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ˜8 J cm-2. This is significantly above the expected threshold for the onset of "blanking" effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate "blanking." Estimates suggest that an areal density of 1019 cm-2 Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  4. Grazing-incidence small-angle X-ray scattering from thin polymer films with lamellar structures - the scattering cross section in the distorted-wave Born approximation

    DEFF Research Database (Denmark)

    Posselt, Dorthe; Busch, Peter; Rauscher, Markus

    2006-01-01

    Grazing-incidence small-angle X-ray or neutron scattering of thin polymer films reveals information about the ordering and preferential orientations of the phase-separated microdomains within the films. The grazing-incidence geometry enhances the surface sensitivity; however, the scattering has t...

  5. Structural characterization of the human cerebral myelin sheath by small angle x-ray scattering

    Science.gov (United States)

    DeFelici, M.; Felici, R.; Ferrero, C.; Tartari, A.; Gambaccini, M.; Finet, S.

    2008-10-01

    Myelin is a multi-lamellar membrane surrounding neuronal axons and increasing their conduction velocity. When investigated by small-angle x-ray scattering (SAXS), the lamellar quasi-periodical arrangement of the myelin sheath gives rise to distinct peaks, which allow the determination of its molecular organization and the dimensions of its substructures. In this study we report on the myelin sheath structural determination carried out on a set of human brain tissue samples coming from surgical biopsies of two patients: a man around 60 and a woman nearly 90 years old. The samples were extracted either from white or grey cerebral matter and did not undergo any manipulation or chemical-physical treatment, which could possibly have altered their structure, except dipping them into a formalin solution for their conservation. Analysis of the scattered intensity from white matter of intact human cerebral tissue allowed the evaluation not only of the myelin sheath periodicity but also of its electronic charge density profile. In particular, the thicknesses of the cytoplasm and extracellular regions were established, as well as those of the hydrophilic polar heads and hydrophobic tails of the lipid bilayer. SAXS patterns were measured at several locations on each sample in order to establish the statistical variations of the structural parameters within a single sample and among different samples. This work demonstrates that a detailed structural analysis of the myelin sheath can also be carried out in randomly oriented samples of intact human white matter, which is of importance for studying the aetiology and evolution of the central nervous system pathologies inducing myelin degeneration.

  6. Structural characterization of the human cerebral myelin sheath by small angle x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    De Felici, M; Felici, R; Ferrero, C [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble Cedex 9 (France); Tartari, A; Gambaccini, M [Physics Department, University of Ferrara, 44100 Ferrara (Italy); Finet, S [Universite Pierre et Marie Curie, BP29, 75252 Paris Cedex 05 (France)

    2008-10-21

    Myelin is a multi-lamellar membrane surrounding neuronal axons and increasing their conduction velocity. When investigated by small-angle x-ray scattering (SAXS), the lamellar quasi-periodical arrangement of the myelin sheath gives rise to distinct peaks, which allow the determination of its molecular organization and the dimensions of its substructures. In this study we report on the myelin sheath structural determination carried out on a set of human brain tissue samples coming from surgical biopsies of two patients: a man around 60 and a woman nearly 90 years old. The samples were extracted either from white or grey cerebral matter and did not undergo any manipulation or chemical-physical treatment, which could possibly have altered their structure, except dipping them into a formalin solution for their conservation. Analysis of the scattered intensity from white matter of intact human cerebral tissue allowed the evaluation not only of the myelin sheath periodicity but also of its electronic charge density profile. In particular, the thicknesses of the cytoplasm and extracellular regions were established, as well as those of the hydrophilic polar heads and hydrophobic tails of the lipid bilayer. SAXS patterns were measured at several locations on each sample in order to establish the statistical variations of the structural parameters within a single sample and among different samples. This work demonstrates that a detailed structural analysis of the myelin sheath can also be carried out in randomly oriented samples of intact human white matter, which is of importance for studying the aetiology and evolution of the central nervous system pathologies inducing myelin degeneration.

  7. X-ray Raman scattering provides evidence for interfacial acetonitrile-water dipole interactions in aqueous solutions

    Science.gov (United States)

    Huang, Ningdong; Nordlund, Dennis; Huang, Congcong; Bergmann, Uwe; Weiss, Thomas M.; Pettersson, Lars G. M.; Nilsson, Anders

    2011-01-01

    Aqueous solutions of acetonitrile (MeCN) have been studied with oxygen K-edge x-ray Raman scattering (XRS) which is found to be sensitive to the interaction between water and MeCN. The changes in the XRS spectra can be attributed to water directly interacting with MeCN and are reproduced by density functional theory calculations on small clusters of water and MeCN. The dominant structural arrangement features dipole interaction instead of H-bonds between the two species as revealed by the XRS spectra combined with spectrum calculations. Small-angle x-ray scattering shows the largest heterogeneity for a MeCN to water ratio of 0.4 in agreement with earlier small-angle neutron scattering data. PMID:22047254

  8. Synchrotron X-ray Scattering from Self-organized Soft Nanostructures in Clays

    Science.gov (United States)

    Fossum, J. O.

    2009-04-01

    In the general context of self-organization of nanoparticles (in our case clay particles), and transitions in such structures, we study interconnected universal complex physical phenomena such as: (i) spontaneous gravitationally induced phase separation and nematic self-organization in systems of anisotropic clay nanoparticles in aqueous suspension, including studies of isotropic to nematic transitions [1,2] (ii) transitions from biaxial to uniaxial nematics by application of external magnetic field to self-organized systems of the same anisotropic (diamagnetic) clay nanoparticle systems [3,4] (iii) guided self-organization into chainlike structures of the same anisotropic clay nanoparticles in oil suspension when subjected to external electrical fields (electrorheological structures of polarized nanoparticles), and the stability of, and transitions of, such structures, when subjected to external mechanical stress [5,6] The experimental techniques used by us include synchrotron X-ray scattering, neutron scattering, rheometry. microscopy and magnetic resonance. We have demonstrated that clays may be used as good model systems for studies of universal physical phenomena and transitions in self-organized nanostructured soft and complex matter. Self-organization and related transitions in clay systems in particular, may have practical relevance for nano-patterning, properties of nanocomposites, and macroscopically anisotropic gels, among many other applications [7]. The synchrotron experiments have been performed at LNLS-Brazil, PLS- Korea, BNL-USA and ESRF-France. Acknowledgments: Collaborators, postdocs and students at NTNU-Norway, UiO-Norway, IFE-Norway, BNL-USA, LNLS-Brazil, UFPE-Brazil, UnB-Brazil, Univ. Amsterdam-Netherlands, Univ.Paris 7-France and other places. This research has been supported by the Research Council of Norway (RCN), through the NANOMAT, SUP and FRINAT Programs. References 1. J.O. Fossum, E. Gudding, D.d.M. Fonseca, Y. Meheust, E. DiMasi, T

  9. Magnitude and effects of X-ray scatter of a cone-beam micro-CT for small animal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Y.C. [Institute of Nuclear Energy Research, Longtan 32546, Taiwan (China); Jan, M.L. [Institute of Nuclear Energy Research, Longtan 32546, Taiwan (China); Chen, K.W. [Institute of Nuclear Energy Research, Longtan 32546, Taiwan (China); Cheng, Y.D. [Department of Nuclear Science, National Tsing-Hua University, Hsinchu 30043, Taiwan (China); Chuang, K.S. [Department of Nuclear Science, National Tsing-Hua University, Hsinchu 30043, Taiwan (China); Fu, Y.K. [Institute of Nuclear Energy Research, Longtan 32546, Taiwan (China)]. E-mail: fufrank@iner.gov.tw

    2006-12-20

    We have developed a micro-CT system to provide high-resolution and anatomic information to combine with a microPET'' (registered) R4 system. This study was to evaluate the magnitude and effects of scatter for low kVp X-ray in this cone-beam micro-CT system. Slit collimators were used to simulate fan-beam micro-CT for comparison. The magnitudes of X-ray scatter were measured using the beam-stop method and were estimated by polynomial-fitting extrapolation to 0 mm size of stoppers. The scatter-to-primary ratio at center of the cone-beam system were 45% and 20% for rat and mouse phantoms, respectively, and were reduced to 5.86% and 4.2% in fan-beam geometric setup. The effects of X-ray scatter on image uniformity and contrast ratio were evaluated also. The uniformity response was examined by the profile of the reconstructed image. The degrees of 'cupping' in the fan-beam and cone-beam conditions were 1.75% and 3.81%, respectively, in rat phantom. A contrast phantom consisting of four inserts with physical densities similar to that of acrylic was used for measuring the effect of X-ray scatter on image contrast. Contrast ratios of the inserts and acrylic in cone-beam setup degraded 36.9% in average compared with fan-beam setup. A tumor-bearing mouse was scanned by the micro-CT system. The tumor-to-background contrast ratios were measured to be 0.331 and 0.249, respectively, with fan-beam and cone-beam setups.

  10. Thorough small-angle X-ray scattering analysis of the instability of liquid micro-jets in air.

    Science.gov (United States)

    Marmiroli, Benedetta; Cacho-Nerin, Fernando; Sartori, Barbara; Pérez, Javier; Amenitsch, Heinz

    2014-01-01

    Liquid jets are of interest, both for their industrial relevance and for scientific applications (more important, in particular for X-rays, after the advent of free-electron lasers that require liquid jets as sample carrier). Instability mechanisms have been described theoretically and by numerical simulation, but confirmed by few experimental techniques. In fact, these are mainly based on cameras, which is limited by the imaging resolution, and on light scattering, which is hindered by absorption, reflection, Mie scattering and multiple scattering due to complex air/liquid interfaces during jet break-up. In this communication it is demonstrated that synchrotron small-angle X-ray scattering (SAXS) can give quantitative information on liquid jet dynamics at the nanoscale, by detecting time-dependent morphology and break-up length. Jets ejected from circular tubes of different diameters (100-450 µm) and speeds (0.7-21 m s(-1)) have been explored to cover the Rayleigh and first wind-induced regimes. Various solvents (water, ethanol, 2-propanol) and their mixtures have been examined. The determination of the liquid jet behaviour becomes essential, as it provides background data in subsequent studies of chemical and biological reactions using SAXS or X-ray diffraction based on synchrotron radiation and free-electron lasers.

  11. Rayleigh scattering of 66Dy-K X-rays in elements with 22 ≤ Z ≤ 90

    Science.gov (United States)

    Singh, Gurjot; Upmanyu, Arun; Singh, Prem; Kainth, H. S.; Shahi, J. S.; Singh, Ranjit; Kumar, Sanjeev

    2017-12-01

    Rayleigh scattering differential cross sections for the 45.2 keV (66Dy Kα2), 46.0 keV (66Dy Kα1) and 52.1 keV (66Dy Kβ1,3) X-rays have been measured at 139° in 44 elements with 22 ≤ Z ≤ 90. The measurements were performed using a radiation source consisting of an annular 66Dy foil excited by the 59.54 keV γ-ray photons from 241Am radioactive source. Intensity of the incident photons along with other geometrical factors were determined by measuring the isotropically emitted K X-ray yields from targets and knowledge of the corresponding K X-ray fluorescence cross sections. The measured Rayleigh scattering cross sections are compared with those based on various form factor formalisms and the state-of-the-art S-matrix calculations to differentiate between their relative efficacies. The scattering cross sections based on the modified form factor (MF) formalism exhibit large deviations for the elements with electron binding energies in vicinity of the incident photon energy, and these deviations smooth out on inclusion of the anomalous scattering factors (ASFs) to the MF values. The cross sections based on the MF after including ASF's are found to be on an average higher by 8% as compared to the measured ones. The S-matrix values exhibit in general good agreement with the measured cross sections for the elements with 22 ≤ Z ≤ 90.

  12. X-ray resonant magnetic scattering study of magnetic stripe domains in a-GdFe thin films

    Science.gov (United States)

    Miguel, J.; Peters, J. F.; Toulemonde, O. M.; Dhesi, S. S.; Brookes, N. B.; Goedkoop, J. B.

    2006-09-01

    X-ray resonant magnetic scattering (XRMS) has been used to investigate the structure of magnetic stripe domain patterns in thin amorphous GdFe films. Under the influence of a perpendicular magnetic field, the scattered intensity displays a smooth transition from a structure factor of correlated stripes to the form factor of isolated domains. We derive a quite general expression that relates the total scattered intensity of XRMS to the absolute value of the magnetization. Furthermore, we compare our results for the domain period with domain theory. We obtain good agreement for prealigned stripes, but disorder tends to lead to an overestimation of the period measured with XRMS.

  13. Ion distributions at charged aqueous surfaces: Synchrotron X-ray scattering studies

    Energy Technology Data Exchange (ETDEWEB)

    Bu, Wei [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    Surface sensitive synchrotron X-ray scattering studies were performed to obtain the distribution of monovalent ions next to a highly charged interface at room temperature. To control surface charge density, lipids, dihexadecyl hydrogen-phosphate (DHDP) and dimysteroyl phosphatidic acid (DMPA), were spread as monolayer materials at the air/water interface, containing CsI at various concentrations. Five decades in bulk concentrations (CsI) are investigated, demonstrating that the interfacial distribution is strongly dependent on bulk concentration. We show that this is due to the strong binding constant of hydronium H3O+ to the phosphate group, leading to proton-transfer back to the phosphate group and to a reduced surface charge. Using anomalous reflectivity off and at the L3 Cs+ resonance, we provide spatial counterion (Cs+) distributions next to the negatively charged interfaces. The experimental ion distributions are in excellent agreement with a renormalized surface charge Poisson-Boltzmann theory for monovalent ions without fitting parameters or additional assumptions. Energy Scans at four fixed momentum transfers under specular reflectivity conditions near the Cs+ L3 resonance were conducted on 10-3 M CsI with DHDP monolayer materials on the surface. The energy scans exhibit a periodic dependence on photon momentum transfer. The ion distributions obtained from the analysis are in excellent agreement with those obtained from anomalous reflectivity measurements, providing further confirmation to the validity of the renormalized surface charge Poisson-Boltzmann theory for monovalent ions. Moreover, the dispersion corrections f0 and f00 for Cs+ around L3 resonance, revealing the local environment of a Cs+ ion in the solution at the interface, were extracted simultaneously with output of ion distributions.

  14. An Assessment of Critical Dimension Small Angle X-ray Scattering Metrology for Advanced Semiconductor Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Settens, Charles M. [State Univ. of New York (SUNY), Albany, NY (United States)

    2015-01-01

    Simultaneous migration of planar transistors to FinFET architectures, the introduction of a plurality of materials to ensure suitable electrical characteristics, and the establishment of reliable multiple patterning lithography schemes to pattern sub-10 nm feature sizes imposes formidable challenges to current in-line dimensional metrologies. Because the shape of a FinFET channel cross-section immediately influences the electrical characteristics, the evaluation of 3D device structures requires measurement of parameters beyond traditional critical dimension (CD), including their sidewall angles, top corner rounding and footing, roughness, recesses and undercuts at single nanometer dimensions; thus, metrologies require sub-nm and approaching atomic level measurement uncertainty. Synchrotron critical dimension small angle X-ray scattering (CD-SAXS) has unique capabilities to non-destructively monitor the cross-section shape of surface structures with single nanometer uncertainty and can perform overlay metrology to sub-nm uncertainty. In this dissertation, we perform a systematic experimental investigation using CD-SAXS metrology on a hierarchy of semiconductor 3D device architectures including, high-aspect-ratio contact holes, H2 annealed Si fins, and a series of grating type samples at multiple points along a FinFET fabrication process increasing in structural intricacy and ending with fully fabricated FinFET. Comparative studies between CD-SAXS metrology and other relevant semiconductor dimensional metrologies, particularly CDSEM, CD-AFM and TEM are used to determine physical limits of CD-SAXS approach for advanced semiconductor samples. CD-SAXS experimental tradeoffs, advice for model-dependent analysis and thoughts on the compatibility with a semiconductor manufacturing environment are discussed.

  15. An Assessment of Critical Dimension Small Angle X-ray Scattering Metrology for Advanced Semiconductor Manufacturing

    Science.gov (United States)

    Settens, Charles M.

    Simultaneous migration of planar transistors to FinFET architectures, the introduction of a plurality of materials to ensure suitable electrical characteristics, and the establishment of reliable multiple patterning lithography schemes to pattern sub-10 nm feature sizes imposes formidable challenges to current in-line dimensional metrologies. Because the shape of a FinFET channel cross-section immediately influences the electrical characteristics, the evaluation of 3D device structures requires measurement of parameters beyond traditional critical dimension (CD), including their sidewall angles, top corner rounding and footing, roughness, recesses and undercuts at single nanometer dimensions; thus, metrologies require sub-nm and approaching atomic level measurement uncertainty. Synchrotron critical dimension small angle X-ray scattering (CD-SAXS) has unique capabilities to non-destructively monitor the cross-section shape of surface structures with single nanometer uncertainty and can perform overlay metrology to sub-nm uncertainty. In this dissertation, we perform a systematic experimental investigation using CD-SAXS metrology on a hierarchy of semiconductor 3D device architectures including, high-aspect-ratio contact holes, H 2 annealed Si fins, and a series of grating type samples at multiple points along a FinFET fabrication process increasing in structural intricacy and ending with fully fabricated FinFET. Comparative studies between CD-SAXS metrology and other relevant semiconductor dimensional metrologies, particularly CD-SEM, CD-AFM and TEM are used to determine physical limits of CD-SAXS approach for advanced semiconductor samples. CD-SAXS experimental tradeoffs, advice for model-dependent analysis and thoughts on the compatibility with a semiconductor manufacturing environment are discussed.

  16. Thomson scattering laser-electron X-ray source for reduction of patient radiation dose in interventional coronary angiography

    Science.gov (United States)

    Artyukov, I. A.; Dyachkov, N. V.; Feshchenko, R. M.; Polunina, A. V.; Popov, N. L.; Shvedunov, V. I.; Vinogradov, A. V.

    2017-05-01

    It was medical applications that stimulated F. Carrol in the early 1990s to start the research of on relativistic Thomson scattering X-ray sources, as a part of the infrastructure of the future society. The possibility to use such a source in interventional cardiology is discussed in this paper. The replacement of X-ray tube by relativistic Thomson scattering Xray source is predicted to lower the patient radiation dose by a factor of 3 while image quality remains the same. The required general characteristics of accelerator and laser units are found. They can be reached by existing technology. A semiempirical method for simulation of medical and technical parameters of interventional coronary angiography systems is suggested.

  17. Interplay between structure and magnetism in HoxPr1-x alloys. 2. Resonant x-ray magnetic scattering

    DEFF Research Database (Denmark)

    Vigliante, A.; Christensen, M.J.; Hill, J.P.

    1998-01-01

    X-ray-scattering techniques have been used to study the crystal and magnetic structures of HoxPr1-x alloys in the form of thin films. Three distinct crystal structures are found as a function of concentration x, each of which has a characteristic magnetic structure. For x greater than or equal to 0.......6 a hexagonal-close-packed phase is found with the magnetic moments ordered in a basal-plane helix, whereas for 0.4 less than or equal to x... hexagonal-close-packed and remain nonmagnetic down to the lowest temperatures studied. Using x-ray magnetic resonance scattering techniques, we demonstrate that a small, static spin-density wave is induced within the alloy 5d band at both the Pr and Ho sites in both of the magnetically ordered phases...

  18. Performance of the micro-PIC gaseous area detector in small-angle X-ray scattering experiments.

    Science.gov (United States)

    Hattori, Kaori; Tsuchiya, Ken'ichi; Ito, Kazuki; Okada, Yoko; Fujii, Kotaro; Kubo, Hidetoshi; Miuchi, Kentaro; Takata, Masaki; Tanimori, Toru; Uekusa, Hidehiro

    2009-03-01

    The application of a two-dimensional photon-counting detector based on a micro-pixel gas chamber (micro-PIC) to high-resolution small-angle X-ray scattering (SAXS), and its performance, are reported. The micro-PIC is a micro-pattern gaseous detector fabricated by printed circuit board technology. This article describes the performance of the micro-PIC in SAXS experiments at SPring-8. A dynamic range of >10(5) was obtained for X-ray scattering from a polystyrene sphere solution. A maximum counting rate of up to 5 MHz was observed with good linearity and without saturation. For a diffraction pattern of collagen, weak peaks were observed in the high-angle region in one accumulation of photons.

  19. Small-angle X-ray scattering: a bridge between RNA secondary structures and three-dimensional topological structures

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Xianyang [National Inst. of Health (NIH), Bethesda, MD (United States). National Cancer Inst., NCI Small Angle X-ray Scattering Core Facility; Stagno, Jason R. [National Inst. of Health (NIH), Bethesda, MD (United States). National Cancer Inst., Protein-Nucleic Acid Interaction Section, Structural Biophysics Lab.; Bhandari, Yuba R. [National Inst. of Health (NIH), Bethesda, MD (United States). National Cancer Inst., Protein-Nucleic Acid Interaction Section, Structural Biophysics Lab.; Zuo, Xiaobing [Argonne National Lab. (ANL), Argonne, IL (United States). Advanced Photon Source (APS); Wang, Yun-Xing [National Inst. of Health (NIH), Bethesda, MD (United States). National Cancer Inst., NCI Small Angle X-ray Scattering Core Facility; National Inst. of Health (NIH), Bethesda, MD (United States). National Cancer Inst., Protein-Nucleic Acid Interaction Section, Structural Biophysics Lab.

    2015-02-01

    Whereas the structures of small to medium-sized well folded RNA molecules often can be determined by either X-ray crystallography or NMR spectroscopy, obtaining structural information for large RNAs using experimental, computational, or combined approaches remains a major interest and challenge. RNA is very sensitive to small-angle X-ray scattering (SAXS) due to high electron density along phosphate-sugar backbones, whose scattering contribution dominates SAXS intensity. For this reason, SAXS is particularly useful in obtaining global RNA structural information that outlines backbone topologies and, therefore, molecular envelopes. Such information is extremely valuable in bridging the gap between the secondary structures and three-dimensional topological structures of RNAmolecules, particularly those that have proven difficult to study using other structuredetermination methods. Here we review published results of RNA topological structures derived from SAXS data or in combination with other experimental data, as well as details on RNA sample preparation for SAXS experiments.

  20. Small angle X-ray scattering and transmission electron microscopy study of the Lactobacillus brevis S-layer protein

    Science.gov (United States)

    Jääskeläinen, Pentti; Engelhardt, Peter; Hynönen, Ulla; Torkkeli, Mika; Palva, Airi; Serimaa, Ritva

    2010-10-01

    The structure of self-assembly domain containing recombinant truncation mutants of Lactobacillus brevis surface layer protein SlpA in aqueous solution was studied using small-angle X-ray scattering and transmission electron microscopy. The proteins were found out to interact with each other forming stable globular oligomers of about 10 monomers. The maximum diameter of the oligomers varied between 75 Å and 435 Å.

  1. Analysis of the aggregation structure from amphiphilic block copolymers in solutions by small-angle x-ray scattering

    CERN Document Server

    Rong Li Xia; Wang Jun; Wei Liu He; Li Fu Mian; Li Zi Chen

    2002-01-01

    The aggregation structure of polystyrene-p vinyl benzoic amphiphilic block copolymers which were prepared in different conditions was investigated by synchrotron radiation small-angle x-ray scattering (SAXS). The micelle was self-assembled in selective solvents of the block copolymers. Authors' results demonstrate that the structure of the micelle depends on the factors, such as the composition of the copolymers, the nature of the solvent and the concentration of the solution

  2. Small angle X-ray scattering and transmission electron microscopy study of the Lactobacillus brevis S-layer protein

    Energy Technology Data Exchange (ETDEWEB)

    Jaeaeskelaeinen, Pentti [Department of Biomedical Engineering and Computational Science, PO Box 2200, FI-02015 Aalto University School of Science and Technology (Finland); Engelhardt, Peter [Haartman Institute, Department of Pathology, PO Box 21, FIN-00014 University of Helsinki (Finland); Hynoenen, Ulla; Palva, Airi [Department of Basic Veterinary Sciences, Division of Microbiology, FIN-00014 University of Helsinki (Finland); Torkkeli, Mika; Serimaa, Ritva, E-mail: ritva.serimaa@helsinki.f [Department of Physics, POB 64, 00014 University of Helsinki (Finland)

    2010-10-01

    The structure of self-assembly domain containing recombinant truncation mutants of Lactobacillus brevis surface layer protein SlpA in aqueous solution was studied using small-angle X-ray scattering and transmission electron microscopy. The proteins were found out to interact with each other forming stable globular oligomers of about 10 monomers. The maximum diameter of the oligomers varied between 75 A and 435 A.

  3. Thermal degradation of M41S-class mesoporous sieves as revealed by small angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, J. E.; Xu, L.; Winans, R. E.; Seifert, S.

    2000-02-16

    The authors have studied the temperature stability of M41S class siliceous mesoporous materials loaded with carbonaceous material by temperature programmed small-angle X-ray scattering (TPSAXS) techniques. Results show the thermal structural instability of large pore pure silica sieve material with carbonaceous material (such as coal extracts) occluded within the pores of mesoporous 31 {angstrom} M41S materials. Unfilled pore M41S materials do not show thermal-related structural instability.

  4. A Grazing-Incidence Small-Angle X-Ray Scattering View of Vertically Aligned ZnO Nanowires

    Directory of Open Access Journals (Sweden)

    M. Lučić Lavčević

    2013-01-01

    Full Text Available We report a grazing-incidence small-angle X-ray scattering study of ZnO films with vertically aligned and randomly distributed nanowires, grown through a hydrothermal growth process on nanostructured ZnO seeding coatings and deposited by electron beam evaporation on silicon and glass, respectively. The comparison of the scattering patterns of seeding coatings and nanowires showed that the scattering of vertically aligned nanowires exhibited a specific feature: the dominant characteristic of their scattering patterns is the appearance of fine structure effects around the specular peak. These effects were clarified by the combined reflection and scattering phenomena, suggested for the aligned nanowires-substrate system. Furthermore, they enabled the calculation of the average gyration radius of nanowires in horizontal direction. The calculated value was in good agreement with the radii of nanowires estimated by surface electron microscopy. Therefore, the observed feature in the scattering pattern can serve as evidence of the aligned growth of nanowires.

  5. Melting and band gap-dynamics of shock-compressed graphite diagnosed by x-ray scattering at the LCLS

    Science.gov (United States)

    Zastrau, Ulf; Lee, Hae Ja

    2015-11-01

    The diversity of the electronic properties of carbon makes it of key interest to the material science community; By contrast, at the high pressures typical of planetary and stellar interiors, the behavior of carbon is poorly understood with large uncertainties in the conductivity and even the material phase. Tremendous efforts have been made to measure properties of warm dense matter (WDM) in extreme conditions, e.g. temperatures in excess of 1000 K of temperature and pressures in the Mbar regime. In laboratory experiments, practical issues with gradients in the temperature and density of shock compressed matter have hindered accurate measurement and further from distinguishing theoretical models. Here, we present measurements of melting of graphite upon coalescence of two counter-propagating shocks using combinations of spatially and spectrally resolved x-ray scattering methods at the LCLS free electron laser. The MEC nanosecond lasers launch counter-propagating shock waves into graphite. At shock coalescence, pressures in excess of 1 Mbar are reached. At given time delay, we measure scattering from the sample using 5070 eV x-ray pulses. We employed curved mosaic and perfect imaging crystals for spatially resolved x-ray scattering. Compared with hydrodynamics simulations, we present data on plasmon dispersion, axial compression gradients and finally carbon melting at shock coalescence. We have indication for a widening of the band gap during compression of the solid, while the band gab fully closes in the melt. UZ was supported by the German Volkswagen Foundation.

  6. X-Ray Polarimetry

    OpenAIRE

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band ...

  7. Global small-angle X-ray scattering data analysis for multilamellar vesicles: the evolution of the scattering density profile model.

    Science.gov (United States)

    Heftberger, Peter; Kollmitzer, Benjamin; Heberle, Frederick A; Pan, Jianjun; Rappolt, Michael; Amenitsch, Heinz; Kučerka, Norbert; Katsaras, John; Pabst, Georg

    2014-02-01

    The highly successful scattering density profile (SDP) model, used to jointly analyze small-angle X-ray and neutron scattering data from unilamellar vesicles, has been adapted for use with data from fully hydrated, liquid crystalline multilamellar vesicles (MLVs). Using a genetic algorithm, this new method is capable of providing high-resolution structural information, as well as determining bilayer elastic bending fluctuations from standalone X-ray data. Structural parameters such as bilayer thickness and area per lipid were determined for a series of saturated and unsaturated lipids, as well as binary mixtures with cholesterol. The results are in good agreement with previously reported SDP data, which used both neutron and X-ray data. The inclusion of deuterated and non-deuterated MLV neutron data in the analysis improved the lipid backbone information but did not improve, within experimental error, the structural data regarding bilayer thickness and area per lipid.

  8. X-ray and neutron scattering on disordered nanosize clusters: a case study of lead-zirconate-titanate solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Frantti, Johannes; Fujioka, Yukari [Finnish Research and Engineering, Helsinki (Finland)

    2015-04-01

    Defects and frequently used defect models of solids are reviewed. Signatures for identifying the disorder from x-ray and neutron scattering data are given. To give illustrative examples how technologically important defects contribute to x-ray and neutron scattering numerical method able to treat non-periodical solids possessing several simultaneous defect types is given for simulating scattering in nanosize disordered clusters. The approach takes particle size, shape, and defects into account and isolates element specific signals. As a case study a statistical approximation model for lead-zirconate titanate [Pb(Zr{sub x}Ti{sub 1-x})O{sub 3}, PZT] is introduced. PZT is a material possessing several defect types, including substitutional, displacement and surface defects. Spatial composition variation is taken into account by introducing a model in which the edge lengths of each cell depend on the distribution of Zr and Ti ions in the cluster. Spatially varying edge lengths and angles is referred to as microstrain. The model is applied to compute the scattering from ellipsoid shaped PZT clusters and to simulate the structural changes as a function of average composition. Two-phase co-existence range, the so called morphotropic phase boundary composition is given correctly. The composition at which the rhombohedral and tetragonal cells are equally abundant was x ∼ 0.51. Selected x-ray and neutron Bragg reflection intensities and line shapes were simulated. Examples of the effect of size and shape of the scattering clusters on diffraction patterns are given and the particle dimensions, computed through Scherrer equation, are compared with the exact cluster dimensions. Scattering from two types of 180 domains in spherical particles, one type assigned to Ti-rich PZT and the second to the MPB and Zr-rich PZT, is computed. We show how the method can be used for modelling polarization reversal. (copyright 2015 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: the microfocus endstation.

    Science.gov (United States)

    Buffet, Adeline; Rothkirch, André; Döhrmann, Ralph; Körstgens, Volker; Abul Kashem, Mottakin M; Perlich, Jan; Herzog, Gerd; Schwartzkopf, Matthias; Gehrke, Rainer; Müller-Buschbaum, Peter; Roth, Stephan V

    2012-07-01

    The P03 beamline, also called the microfocus and nanofocus X-ray scattering (MiNaXS) beamline, exploits the excellent photon beam properties of the low-emittance source PETRA III to provide a microfocused/nanofocused beam with ultra-high intensity for time-resolved X-ray scattering experiments. The beamline has been designed to perform X-ray scattering in both transmission and reflection geometries. The microfocus endstation started user operation in May 2011. An overview of the beamline status and of some representative results highlighting the performance of the microfocus endstation at MiNaXS are given.

  10. Synthesis of Novel Amphiphilic Azobenzenes and X-ray Scattering Studies of Their Langmuir Monolayers

    DEFF Research Database (Denmark)

    Sørensen, Thomas Just; Kjær, Kristian; Breiby, Dag Werner

    2008-01-01

    . At the air-water interface, the amphiphilic azobenzenes form noncrystalline but stable Langmuir films that display an unusual reversible monolayer collapse close to 35 mN/m. The structures and phase transitions were studied by X-ray reflectivity (XR) and grazing-incidence X-ray diffraction, both utilizing...... synchrotron radiation. Compression beyond the collapse point does not change the XR data, showing that the film is unchanged at the molecular level, even at areas less than half of that of the collapse. This leads to the conclusion that few macroscopic collapse sites are responsible for reversibly removing...

  11. Cholesterol-phospholipid interactions: new insights from surface x-ray scattering data.

    Science.gov (United States)

    Ivankin, Andrey; Kuzmenko, Ivan; Gidalevitz, David

    2010-03-12

    We report a structural study of cholesterol-DPPC (1,2-dipalmitoyl-sn-glycero-3-phophocholine) monolayers using x-ray reflectivity and grazing incidence x-ray diffraction. Reflectivity reveals that the vertical position of cholesterol relative to phospholipids strongly depends on its mole fraction (chi(CHOL)). Moreover, we find that at a broad range of chi(CHOL) cholesterol and DPPC form alloylike mixed domains of short-range order and the same stoichiometry as that of the film. Based on the data presented, we propose a new model of cholesterol-phospholipid organization in mixed monolayers.

  12. Anomalous Small-angle X-ray Scattering Study on Aggregation of a Block Copolymer in a Selective Solvent

    Energy Technology Data Exchange (ETDEWEB)

    Sakou, Megumi; Takechi, Atsuro; Sakurai, Kazuo; Akiba, Isamu [Department of Chemistry, University of Kitakyushu (Japan); Handa, Masashi; Shinohara, Yuya; Amemiya, Yoshiyuki [Department of Advanced Materials Science, University of Kyoto (Japan); Masunaga, Hiroyasu; Ogawa, Hiroki; Yagi, Naoto, E-mail: akiba@env.kitakyu-u.ac.jp [Japan Synchrotron Research Institute (Japan)

    2011-01-01

    Anomalous small-angle X-ray Scattering (ASAXS) analysis for poly(4-vinylphenol)-b-poly(4-bromostyrene) (PVPh-b-PBrS) in N,N,N',N'-tetramethyl ethylene diamine (TMEDA) solution was examined. The ASAXS measurements, executed at three different energies, provided the separation of the scattering of the Br atoms from whole system. The energy-dependent term in the SAXS profile, which is corresponding to the form factor of PBrS domain, sufficiently agree with the SAXS profile calculated for hard sphere with 41 nm radius. Therefore, the PBrS chains assemble into spherical core with 41 nm radius in TMEDA solution.

  13. Small-angle Thomson scattering of ultrafast laser pulses for bright, sub-100-fs x-ray radiation

    Directory of Open Access Journals (Sweden)

    Yuelin Li

    2002-04-01

    Full Text Available We propose a scheme for bright sub-100-fs x-ray radiation generation using small-angle Thomson scattering. Coupling high-brightness electron bunches with high-power ultrafast laser pulses, radiation with photon energies between 8 and 40 keV can be generated with pulse duration comparable to that of the incoming laser pulse and with peak spectral brightness close to that of the third-generation synchrotron light sources of ∼10^{20} photons s^{-1} mm^{-2} mrad^{-2} per 10^{-3} bandwidth. A preliminary dynamic calculation is performed to understand the property of this novel scattering scheme with relativistic laser intensities.

  14. Myelin structure is a key difference in the x-ray scattering signature between meningioma, schwannoma and glioblastoma multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Falzon, G [Physics and Electronics, School of Biological, Biomedical and Molecular Sciences, University of New England, Armidale, NSW 2351 (Australia); Pearson, S [Physics and Electronics, School of Biological, Biomedical and Molecular Sciences, University of New England, Armidale, NSW 2351 (Australia); Murison, R [School of Mathematics, Statistics and Computer Science, University of New England, Armidale, NSW 2351 (Australia); Hall, C [School of Physics, Monash University, Victoria 3800 (Australia); Siu, K [School of Physics, Monash University, Victoria 3800 (Australia); Round, A [European Molecular Biology Laboratory, Hamburg Outstation, Notkestrasse 85, 22603 Hamburg (Germany); Schueltke, E [Division of Neurosurgery, University of Sakatchewan, Saskatoon S7N 5E5 (Canada); Kaye, A H [Department of Surgery, University of Melbourne, Parkville, 3050 (Australia); Lewis, R [Monash Centre for Synchrotron Science, Monash University, Victoria 3800 (Australia)

    2007-11-07

    Small angle x-ray scattering (SAXS) patterns of benign and malignant brain tumour tissue were examined. Independent component analysis was used to find a feature set representing the images collected. A set of coefficients was then used to describe each image, which allowed the use of the statistical technique of flexible discriminant analysis to discover a hidden order in the data set. The key difference was found to be in the intensity and spectral content of the second and fourth order myelin scattering peaks. This has clearly demonstrated that significant differences in the structure of myelin exist in the highly malignant glioblastoma multiforme as opposed to the benign: meningioma and schwannoma.

  15. Organic Molecules and Network Polymers of Intrinsic Microporosity: Structural Characterization via X-ray Scattering and Simulations

    Science.gov (United States)

    McDermott, Amanda G.; Abbott, Lauren J.; Del Regno, Annalaura; Msayib, Kadhum J.; Ghanem, Bader S.; Taylor, Rupert; Carta, Mariolino; McKeown, Neil B.; Budd, Peter M.; Siperstein, Flor R.; Colina, Coray M.; Runt, James

    2011-03-01

    Like polymers of intrinsic microporosity (PIMs), organic molecules of intrinsic microporosity (OMIMs) are glassy solids featuring a large concentration of pores smaller than 2 nm and large internal surface area as measured by gas sorption experiments. OMIMs are oligomers designed to fill space inefficiently, consisting of several rigid segments joined at one vertex to produce concave faces. Both X-ray scattering patterns and simulations provide insight into the packing geometry and short-range order of these molecules. We also discuss the interpretation of scattering patterns from two- and three-dimensional network PIMs. Supported by NSF/Materials World Network/EPSRC and the NSF Graduate Research Fellowship Program.

  16. Noninvasive Synchrotron-Based X-ray Raman Scattering Discriminates Carbonaceous Compounds in Ancient and Historical Materials.

    Science.gov (United States)

    Gueriau, Pierre; Rueff, Jean-Pascal; Bernard, Sylvain; Kaddissy, Josiane A; Goler, Sarah; Sahle, Christoph J; Sokaras, Dimosthenis; Wogelius, Roy A; Manning, Phillip L; Bergmann, Uwe; Bertrand, Loïc

    2017-10-17

    Carbon compounds are ubiquitous and occur in a diversity of chemical forms in many systems including ancient and historic materials ranging from cultural heritage to paleontology. Determining their speciation cannot only provide unique information on their origin but may also elucidate degradation processes. Synchrotron-based X-ray absorption near-edge structure (XANES) spectroscopy at the carbon K-edge (280-350 eV) is a very powerful method to probe carbon speciation. However, the short penetration depth of soft X-rays imposes stringent constraints on sample type, preparation, and analytical environment. A hard X-ray probe such as X-ray Raman scattering (XRS) can overcome many of these difficulties. Here we report the use of XRS at ∼6 keV incident energy to collect carbon K-edge XANES data and probe the speciation of organic carbon in several specimens relevant to cultural heritage and natural history. This methodology enables the measurement to be done in a nondestructive way, in air, and provides information that is not compromised by surface contamination by ensuring that the dominant signal contribution is from the bulk of the probed material. Using the backscattering geometry at large photon momentum transfer maximizes the XRS signal at the given X-ray energy and enhances nondipole contributions compared to conventional XANES, thereby augmenting the speciation sensitivity. The capabilities and limitations of the technique are discussed. We show that despite its small cross section, for a range of systems the XRS method can provide satisfactory signals at realistic experimental conditions. XRS constitutes a powerful complement to FT-IR, Raman, and conventional XANES spectroscopy, overcoming some of the limitations of these techniques.

  17. Resonant X-Ray Scattering and the jeff=1/2 Electronic Ground State in Iridate Perovskites

    DEFF Research Database (Denmark)

    Sala, M. Moretti; Boseggia, S.; McMorrow, Desmond Francis

    2014-01-01

    The resonant x-ray scattering (magnetic elastic, RXMS, and inelastic, RIXS) of Ir4+ at the L-2,L-3 edges relevant to spin-orbit Mott insulators A(n+1) Ir(n)O3(n+1) (A = Sr, Ba, etc.) are calculated using a single-ion model which treats the spin-orbit and tetragonal crystal-field terms on an equal......-flip RIXS, relevant to measurements of magnons, behaves reciprocally, being zero at L-2 when mu is perpendicular to the ab plane. Our results have important implications for the assignment of a j(eff) = 1/2 ground state on the basis of resonant x-ray experiments.......The resonant x-ray scattering (magnetic elastic, RXMS, and inelastic, RIXS) of Ir4+ at the L-2,L-3 edges relevant to spin-orbit Mott insulators A(n+1) Ir(n)O3(n+1) (A = Sr, Ba, etc.) are calculated using a single-ion model which treats the spin-orbit and tetragonal crystal-field terms on an equal...

  18. A compact permanent-magnet system for measuring magnetic circular dichroism in resonant inelastic soft X-ray scattering.

    Science.gov (United States)

    Miyawaki, Jun; Suga, Shigemasa; Fujiwara, Hidenori; Niwa, Hideharu; Kiuchi, Hisao; Harada, Yoshihisa

    2017-03-01

    A compact and portable magnet system for measuring magnetic dichroism in resonant inelastic soft X-ray scattering (SX-RIXS) has been developed at the beamline BL07LSU in SPring-8. A magnetic circuit composed of Nd-Fe-B permanent magnets, which realised ∼0.25 T at the center of an 11 mm gap, was rotatable around the axis perpendicular to the X-ray scattering plane. Using the system, a SX-RIXS spectrum was obtained under the application of the magnetic field at an angle parallel, nearly 45° or perpendicular to the incident X-rays. A dedicated sample stage was also designed to be as compact as possible, making it possible to perform SX-RIXS measurements at arbitrary incident angles by rotating the sample stage in the gap between the magnetic poles. This system enables facile studies of magnetic dichroism in SX-RIXS for various experimental geometries of the sample and the magnetic field. A brief demonstration of the application is presented.

  19. Three-dimensional Morphology and X-ray Scattering Structure of ...

    Indian Academy of Sciences (India)

    , in the mixtures of water and tert-butanol (TBA) by using simulated X-ray ... heterogeneity order parameters for the individual components of the mixture reveal enhanced non-uniform distribution of the TBA molecules near XTBA ≈ 0.1 to 0.3.

  20. In situ microfluidic dialysis for biological small-angle X-ray scattering

    DEFF Research Database (Denmark)

    Skou, Magda; Skou, Soren; Jensen, Thomas Glasdam

    2014-01-01

    for simultaneous SAXS and ultraviolet absorption measurements during protein dialysis, integrated directly on a SAXS beamline. Microfluidic dialysis can be used for monitoring structural changes in response to buffer exchange or, as demonstrated, protein concentration. By collecting X-ray data during...

  1. Multiple scattering in grazing-incidence X-ray diffraction: impact on lattice-constant determination in thin films

    Energy Technology Data Exchange (ETDEWEB)

    Resel, Roland, E-mail: roland.resel@tugraz.at; Bainschab, Markus; Pichler, Alexander [Graz University of Technology, Graz (Austria); Dingemans, Theo [Delft University of Technology, Delft (Netherlands); Simbrunner, Clemens [Johannes Kepler University, Linz (Austria); University of Bremen, Bremen (Germany); Stangl, Julian [Johannes Kepler University, Linz (Austria); Salzmann, Ingo [Humboldt University, Berlin (Germany)

    2016-04-20

    The use of grazing-incidence X-ray diffraction to determine the crystal structure from thin films requires accurate positions of Bragg peaks. Refraction effects and multiple scattering events have to be corrected or minimized. Dynamical scattering effects are observed in grazing-incidence X-ray diffraction experiments using an organic thin film of 2,2′:6′,2′′-ternaphthalene grown on oxidized silicon as substrate. Here, a splitting of all Bragg peaks in the out-of-plane direction (z-direction) has been observed, the magnitude of which depends both on the incidence angle of the primary beam and the out-of-plane angle of the scattered beam. The incident angle was varied between 0.09° and 0.25° for synchrotron radiation of 10.5 keV. This study reveals comparable intensities of the split peaks with a maximum for incidence angles close to the critical angle of total external reflection of the substrate. This observation is rationalized by two different scattering pathways resulting in diffraction peaks at different positions at the detector. In order to minimize the splitting, the data suggest either using incident angles well below the critical angle of total reflection or angles well above, which sufficiently attenuates the contributions from the second scattering path. This study highlights that the refraction of X-rays in (organic) thin films has to be corrected accordingly to allow for the determination of peak positions with sufficient accuracy. Based thereon, a reliable determination of the lattice constants becomes feasible, which is required for crystallographic structure solutions from thin films.

  2. Evidence for the Importance of Resonance Scattering in X-Ray Emission Line Profiles of the O Star Zeta Puppis

    Energy Technology Data Exchange (ETDEWEB)

    Leutenegger, M.A.; /Columbia U.; Owocki, S.P.; /Bartol Research Inst.; Kahn, S.M.; /KIPAC, Menlo Park; Paerels, F.B.S.; /Columbia U.

    2006-10-10

    We fit the Doppler profiles of the He-like triplet complexes of O VII and N VI in the X-ray spectrum of the O star {zeta} Pup, using XMM-Newton RGS data collected over {approx} 400 ks of exposure. We find that they cannot be well fit if the resonance and intercombination lines are constrained to have the same profile shape. However, a significantly better fit is achieved with a model incorporating the effects of resonance scattering, which causes the resonance line to become more symmetric than the intercombination line for a given characteristic continuum optical depth {tau}{sub *}. We discuss the plausibility of this hypothesis, as well as its significance for our understanding of Doppler profiles of X-ray emission lines in O stars.

  3. Study on the structure of Fe sub 2 O sub 3 xerogels by small angle X-ray scattering

    CERN Document Server

    Liu Yi; Zhao Xin; Yang Tong Hua; Zhao Hui; Rong Li Xia; Zhang Jing; Wang Jun; Dong Bao Zhong

    2002-01-01

    Small angle X-ray scattering (SAXS) with synchrotron radiation as X-ray source is used to study the pore structure of Fe sub 2 O sub 3 xerogels prepared by sol-gel procedure and then heat-treated at different temperatures. By analysing the distribution of diameters of the pores, specific surfaces and fractal behaviors in samples, the characters and mechanisms of pores growing are discussed. The results show that the pores in Fe sub 2 O sub 3 xerogels are polydisperse and the structure of the pores is mass fractal. With increase in heat-treatment temperature, the average size of diameters of the pores and the dimension of fractal of Fe sub 2 O sub 3 xerogels are increased, whereas the scale range possessing fractal behavior become narrow

  4. Nonperturbative Series Expansion of Green's Functions: The Anatomy of Resonant Inelastic X-Ray Scattering in the Doped Hubbard Model

    Science.gov (United States)

    Lu, Yi; Haverkort, Maurits W.

    2017-12-01

    We present a nonperturbative, divergence-free series expansion of Green's functions using effective operators. The method is especially suited for computing correlators of complex operators as a series of correlation functions of simpler forms. We apply the method to study low-energy excitations in resonant inelastic x-ray scattering (RIXS) in doped one- and two-dimensional single-band Hubbard models. The RIXS operator is expanded into polynomials of spin, density, and current operators weighted by fundamental x-ray spectral functions. These operators couple to different polarization channels resulting in simple selection rules. The incident photon energy dependent coefficients help to pinpoint main RIXS contributions from different degrees of freedom. We show in particular that, with parameters pertaining to cuprate superconductors, local spin excitation dominates the RIXS spectral weight over a wide doping range in the cross-polarization channel.

  5. Interface characterization of B4C-based multilayers by X-ray grazing-incidence reflectivity and diffuse scattering.

    Science.gov (United States)

    Jiang, Hui; Wang, Zhanshan; Zhu, Jingtao

    2013-05-01

    B4C-based multilayers have important applications for soft to hard X-rays. In this paper, X-ray grazing-incidence reflectivity and diffuse scattering, combining various analysis methods, were used to characterize the structure of B4C-based multilayers including layer thickness, density, interfacial roughness, interdiffusion, correlation length, etc. Quantitative results for W/B4C, Mo/B4C and La/B4C multilayers were compared. W/B4C multilayers show the sharpest interfaces and most stable structures. The roughness replications of La/B4C and Mo/B4C multilayers are not strong, and oxidations and structure expansions are found in the aging process. This work provides guidance for future fabrication and characterization of B4C-based multilayers.

  6. Resonant inelastic X-ray scattering at the $L_{3}$ edge of $Eu^{2+} Gd^{3+}$, and $Tb^{4+}$ compounds

    CERN Document Server

    Dallera, C; Rogalev, A; Goulon, J; Sette, F

    2002-01-01

    4d to 2p inelastic X-ray scattering (IXS) spectra of Eu/sup 2+/, Gd /sup 3+/ and Tb/sup 4+/ compounds, resonantly enhanced at the rare- earth L/sub 3/ absorption edge, are presented. Despite their common /sup 8/S/sub 7/2/ (4f/sup 7/) ground state, the RIXS spectra display strong differences, arising from the different energy separation between the dipolar (El) and quadrupolar (E2) excitation channels, and the 5d crystal field splitting. The quantitative determination of these energy separations provides further experimental input for the correct interpretation of X-ray Magnetic Circular Dichroism (XMCD) experiments performed at the L/sub 2,3/ edges of the rare-earth compounds. (10 refs).

  7. Compact x-ray source based on burst-mode inverse Compton scattering at 100 kHz

    Directory of Open Access Journals (Sweden)

    W. S. Graves

    2014-12-01

    Full Text Available A design for a compact x-ray light source (CXLS with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and rf photoinjector powered by a single ultrastable rf transmitter at X-band rf frequency. The high efficiency permits operation at repetition rates up to 1 kHz, which is further boosted to 100 kHz by operating with trains of 100 bunches of 100 pC charge, each separated by 5 ns. The entire accelerator is approximately 1 meter long and produces hard x rays tunable over a wide range of photon energies. The colliding laser is a Yb∶YAG solid-state amplifier producing 1030 nm, 100 mJ pulses at the same 1 kHz repetition rate as the accelerator. The laser pulse is frequency-doubled and stored for many passes in a ringdown cavity to match the linac pulse structure. At a photon energy of 12.4 keV, the predicted x-ray flux is 5×10^{11}  photons/second in a 5% bandwidth and the brilliance is 2×10^{12}  photons/(sec mm^{2} mrad^{2}  0.1% in pulses with rms pulse length of 490 fs. The nominal electron beam parameters are 18 MeV kinetic energy, 10 microamp average current, 0.5 microsecond macropulse length, resulting in average electron beam power of 180 W. Optimization of the x-ray output is presented along with design of the accelerator, laser, and x-ray optic components that are specific to the particular characteristics of the Compton scattered x-ray pulses.

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of ionizing radiation to produce pictures of the inside of the body. X-rays are the oldest ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  11. The new NCPSS BL19U2 beamline at the SSRF for small-angle X-ray scattering from biological macromolecules in solution.

    Science.gov (United States)

    Li, Na; Li, Xiuhong; Wang, Yuzhu; Liu, Guangfeng; Zhou, Ping; Wu, Hongjin; Hong, Chunxia; Bian, Fenggang; Zhang, Rongguang

    2016-10-01

    The beamline BL19U2 is located in the Shanghai Synchrotron Radiation Facility (SSRF) and is its first beamline dedicated to biological material small-angle X-ray scattering (BioSAXS). The electrons come from an undulator which can provide high brilliance for the BL19U2 end stations. A double flat silicon crystal (111) monochromator is used in BL19U2, with a tunable monochromatic photon energy ranging from 7 to 15 keV. To meet the rapidly growing demands of crystallographers, biochemists and structural biologists, the BioSAXS beamline allows manual and automatic sample loading/unloading. A Pilatus 1M detector (Dectris) is employed for data collection, characterized by a high dynamic range and a short readout time. The highly automated data processing pipeline SASFLOW was integrated into BL19U2, with help from the BioSAXS group of the European Molecular Biology Laboratory (EMBL, Hamburg), which provides a user-friendly interface for data processing. The BL19U2 beamline was officially opened to users in March 2015. To date, feedback from users has been positive and the number of experimental proposals at BL19U2 is increasing. A description of the new BioSAXS beamline and the setup characteristics is given, together with examples of data obtained.

  12. The new NCPSS BL19U2 beamline at the SSRF for small-angle X-ray scattering from biological macromolecules in solution1

    Science.gov (United States)

    Li, Na; Li, Xiuhong; Wang, Yuzhu; Liu, Guangfeng; Zhou, Ping; Wu, Hongjin; Hong, Chunxia; Bian, Fenggang; Zhang, Rongguang

    2016-01-01

    The beamline BL19U2 is located in the Shanghai Synchrotron Radiation Facility (SSRF) and is its first beamline dedicated to biological material small-angle X-ray scattering (BioSAXS). The electrons come from an undulator which can provide high brilliance for the BL19U2 end stations. A double flat silicon crystal (111) monochromator is used in BL19U2, with a tunable monochromatic photon energy ranging from 7 to 15 keV. To meet the rapidly growing demands of crystallographers, biochemists and structural biologists, the BioSAXS beamline allows manual and automatic sample loading/unloading. A Pilatus 1M detector (Dectris) is employed for data collection, characterized by a high dynamic range and a short readout time. The highly automated data processing pipeline SASFLOW was integrated into BL19U2, with help from the BioSAXS group of the European Molecular Biology Laboratory (EMBL, Hamburg), which provides a user-friendly interface for data processing. The BL19U2 beamline was officially opened to users in March 2015. To date, feedback from users has been positive and the number of experimental proposals at BL19U2 is increasing. A description of the new BioSAXS beamline and the setup characteristics is given, together with examples of data obtained. PMID:27738413

  13. Collimating Montel mirror as part of a multi-crystal analyzer system for resonant inelastic X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jungho; Shi, Xianbo; Casa, Diego; Qian, Jun; Huang, XianRong; Gog, Thomas

    2016-06-01

    Advances in resonant inelastic X-ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the IrL3-edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid-angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the IrL3-absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X-ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27-ID at the Advanced Photon Source. X-rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X-ray measurements, ray-tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high-resolution RIXS multi-crystal analyzer system.

  14. Pair distribution functions of amorphous organic thin films from synchrotron X-ray scattering in transmission mode

    Directory of Open Access Journals (Sweden)

    Chenyang Shi

    2017-09-01

    Full Text Available Using high-brilliance high-energy synchrotron X-ray radiation, for the first time the total scattering of a thin organic glass film deposited on a strongly scattering inorganic substrate has been measured in transmission mode. The organic thin film was composed of the weakly scattering pharmaceutical substance indomethacin in the amorphous state. The film was 130 µm thick atop a borosilicate glass substrate of equal thickness. The atomic pair distribution function derived from the thin-film measurement is in excellent agreement with that from bulk measurements. This ability to measure the total scattering of amorphous organic thin films in transmission will enable accurate in situ structural studies for a wide range of materials.

  15. Pair distribution functions of amorphous organic thin films from synchrotron X-ray scattering in transmission mode.

    Science.gov (United States)

    Shi, Chenyang; Teerakapibal, Rattavut; Yu, Lian; Zhang, Geoff G Z

    2017-09-01

    Using high-brilliance high-energy synchrotron X-ray radiation, for the first time the total scattering of a thin organic glass film deposited on a strongly scattering inorganic substrate has been measured in transmission mode. The organic thin film was composed of the weakly scattering pharmaceutical substance indomethacin in the amorphous state. The film was 130 µm thick atop a borosilicate glass substrate of equal thickness. The atomic pair distribution function derived from the thin-film measurement is in excellent agreement with that from bulk measurements. This ability to measure the total scattering of amorphous organic thin films in transmission will enable accurate in situ structural studies for a wide range of materials.

  16. Determination of structural changes of dispersed clay platelets in a polymer blend during solid-state rheological property measurement by small-angle X-ray scattering

    CSIR Research Space (South Africa)

    Bandyopadhyay, J

    2011-05-01

    Full Text Available -1 Polymer Volume 52, Issue 12, 26 May 2011, Pages 2628?2642 Determination of structural changes of dispersed clay platelets in a polymer blend during solid-state rheological property measurement by small-angle X-ray scattering ? Jayita Bandyopadhyaya... frequency and temperature sweep tests. Graphical abstract Keywords ? Blend composites; ? Small-angle X-ray scattering; ? Solid-state rheology ...

  17. Crystalline Stratification in Semiconducting Polymer Thin Film Quantified by Grazing Incidence X-ray Scattering

    Science.gov (United States)

    Gann, Eliot; Caironi, Mario; Noh, Yong-Young; Kim, Yun-Hi; McNeill, Christopher R.

    The depth dependence of crystalline structure within thin films is critical for many technological applications, but has been impossible to measure directly using common techniques. In this work, by monitoring diffraction peak intensity and location and utilizing the highly angle-dependent waveguiding effects of X-rays near grazing incidence we quantitatively measure the thickness, roughness and orientation of stratified crystalline layers within thin films of a high-performance semiconducting polymer. In particular, this diffractive X-ray waveguiding reveals a self-organized 5-nm-thick crystalline surface layer with crystalline orientation orthogonal to the underlying 65-nm-thick layer. While demonstrated for an organic semiconductor film, this approach is applicable to any thin film material system where stratified crystalline structure and orientation can influence important interfacial processes such as charge injection and field-effect transport.

  18. Fast X-ray reflectivity measurements using an X-ray pixel area detector at the DiffAbs beamline, Synchrotron SOLEIL.

    Science.gov (United States)

    Mocuta, Cristian; Stanescu, Stefan; Gallard, Manon; Barbier, Antoine; Dawiec, Arkadiusz; Kedjar, Bouzid; Leclercq, Nicolas; Thiaudiere, Dominique

    2018-01-01

    This paper describes a method for rapid measurements of the specular X-ray reflectivity signal using an area detector and a monochromatic, well collimated X-ray beam (divergence below 0.01°), combined with a continuous data acquisition mode during the angular movements of the sample and detector. In addition to the total integrated (and background-corrected) reflectivity signal, this approach yields a three-dimensional mapping of the reciprocal space in the vicinity of its origin. Grazing-incidence small-angle scattering signals are recorded simultaneously. Measurements up to high momentum transfer values (close to 0.1 nm-1, also depending on the X-ray beam energy) can be performed in total time ranges as short as 10 s. The measurement time can be reduced by up to 100 times as compared with the classical method using monochromatic X-ray beams, a point detector and rocking scans (integrated reflectivity signal).

  19. X-ray-scattering determination of the Cu(110)-(2x3)N structure

    DEFF Research Database (Denmark)

    Baddorf, A.P.; Zehner, D.M.; Helgesen, G.

    1993-01-01

    The structure of Cu(110)-(2X3)N has been investigated with x-ray reflectivity measurements of nine independent surface rods. Observed reflectivities ranging over five orders of magnitude were compared with calculations based on structural models. A pseudo-(100) reconstruction consisting of four......, and form a nearly (square-root 2 X square-root 2) R 45-degrees structure with respect to the reconstructed copper. This model is shown to be consistent with most previous experimental observations....

  20. Advancing the molecular movie: Femtosecond X-ray scattering of an electrocyclic chemical reaction

    Science.gov (United States)

    Minitti, Michael

    Since it began operation in 2009, SLAC's Linac Coherent Light Source (LCLS) has allowed scientists to make new types of X-ray measurements that were once thought unattainable by delivering one trillion X-ray photons in incredibly short bursts of less than a few femtoseconds. It was promised that this astonishing quantity of photons, delivered in such a small slice of time, could capture the motions of atoms in chemical reactions. Now we have used this capability to make a ``molecular movie'' of a molecule undergoing a chemical reaction from start to finish, with frames just a few femtoseconds long. We assembled the movie by taking individual X-ray snapshots of the molecules that show the positions of their atoms at each moment in time. Comparing these results to computer simulations of the reaction, we determined the routes the individual molecules followed as it's structure rearranged. This is the first step in developing robust methods for visualizing molecular motions in chemistry, biology, and materials science at the atomic scale. Please enjoy the movie! SLAC National Accelerator Laboratory U.S. DOE, Office of Science, Office of Basic Energy Sciences under Contract No. DE-AC02-76SF00515.

  1. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph., E-mail: philippe.troussel@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Dennetiere, D. [Synchrotron Soleil, L’orme des Merisiers, 91190 Saint-Aubin (France); Maroni, R. [CEA, DAM, DIF, F-91297 Arpajon (France); Høghøj, P.; Hedacq, S. [Xenocs SA, 19, rue François Blumet, F-38360 Sassenage (France); Cibik, L.; Krumrey, M. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany)

    2014-12-11

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  2. In-Situ Coherent Grazing Incidence Small Angle X-ray Scattering (Co-GISAXS) Studies of Surface Fluctuations of Sputter Deposited WSi2 using X-ray Photon Correlation Spectroscopy (XPCS)

    Science.gov (United States)

    Dahal, Som; Ulbrandt, Jeffrey; Headrick, Randall; Demasi, Alexander; Ludwig, Karl

    2014-03-01

    We performed Coherent Grazing Incidence Small Angle X-ray Scattering (Co-GISAXS) studies of surface dynamics during magnetron sputtering deposited WSi2 amorphous thin films. The local dynamics of surface fluctuations was studied by X-ray Photon Correlation Spectroscopy (XPCS) in the late time regime where the static GIXAXS stops evolving. Our studies reveal that the correlation time of the sputtered species varies as a power law with the in-plane momentum transfer. The experimentally obtained results are compared with predictions from continuum models of surface growth.

  3. Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.

    Science.gov (United States)

    Alnewaini, Zaid; Langer, Eric; Schaber, Philipp; David, Matthias; Kretz, Dominik; Steil, Volker; Hesser, Jürgen

    2017-03-01

    Dosimetric control of staff exposure during interventional procedures under fluoroscopy is of high relevance. In this paper, a novel ray casting approximation of radiation transport is presented and the potential and limitation vs. a full Monte Carlo transport and dose measurements are discussed. The x-ray source of a Siemens Axiom Artix C-arm is modeled by a virtual source model using single Gaussian-shaped source. A Geant4-based Monte Carlo simulation determines the radiation transport from the source to compute scatter from the patient, the table, the ceiling and the floor. A phase space around these scatterers stores all photon information. Only those photons are traced that hit a surface of phantom that represents medical staff in the treatment room, no indirect scattering is considered; and a complete dose deposition on the surface is calculated. To evaluate the accuracy of the approximation, both experimental measurements using Thermoluminescent dosimeters (TLDs) and a Geant4-based Monte Carlo simulation of dose depositing for different tube angulations of the C-arm from cranial-caudal angle 0° and from LAO (Left Anterior Oblique) 0°-90° are realized. Since the measurements were performed on both sides of the table, using the symmetry of the setup, RAO (Right Anterior Oblique) measurements were not necessary. The Geant4-Monte Carlo simulation agreed within 3% with the measured data, which is within the accuracy of measurement and simulation. The ray casting approximation has been compared to TLD measurements and the achieved percentage difference was -7% for data from tube angulations 45°-90° and -29% from tube angulations 0°-45° on the side of the x-ray source, whereas on the opposite side of the x-ray source, the difference was -83.8% and -75%, respectively. Ray casting approximation for only LAO 90° was compared to a Monte Carlo simulation, where the percentage differences were between 0.5-3% on the side of the x-ray source where the highest dose

  4. X-Ray Solution Scattering Study of Four Escherichia coli Enzymes Involved in Stationary-Phase Metabolism.

    Directory of Open Access Journals (Sweden)

    Liubov A Dadinova

    Full Text Available The structural analyses of four metabolic enzymes that maintain and regulate the stationary growth phase of Escherichia coli have been performed primarily drawing on the results obtained from solution small angle X-ray scattering (SAXS and other structural techniques. The proteins are (i class I fructose-1,6-bisphosphate aldolase (FbaB; (ii inorganic pyrophosphatase (PPase; (iii 5-keto-4-deoxyuronate isomerase (KduI; and (iv glutamate decarboxylase (GadA. The enzyme FbaB, that until now had an unknown structure, is predicted to fold into a TIM-barrel motif that form globular protomers which SAXS experiments show associate into decameric assemblies. In agreement with previously reported crystal structures, PPase forms hexamers in solution that are similar to the previously reported X-ray crystal structure. Both KduI and GadA that are responsible for carbohydrate (pectin metabolism and acid stress responses, respectively, form polydisperse mixtures consisting of different oligomeric states. Overall the SAXS experiments yield additional insights into shape and organization of these metabolic enzymes and further demonstrate the utility of hybrid methods, i.e., solution SAXS combined with X-ray crystallography, bioinformatics and predictive 3D-structural modeling, as tools to enrich structural studies. The results highlight the structural complexity that the protein components of metabolic networks may adopt which cannot be fully captured using individual structural biology techniques.

  5. Ultrahigh brilliance quasi-monochromatic MeV γ-rays based on self-synchronized all-optical Compton scattering

    Science.gov (United States)

    Yu, Changhai; Qi, Rong; Wang, Wentao; Liu, Jiansheng; Li, Wentao; Wang, Cheng; Zhang, Zhijun; Liu, Jiaqi; Qin, Zhiyong; Fang, Ming; Feng, Ke; Wu, Ying; Tian, Ye; Xu, Yi; Wu, Fenxiang; Leng, Yuxin; Weng, Xiufeng; Wang, Jihu; Wei, Fuli; Yi, Yicheng; Song, Zhaohui; Li, Ruxin; Xu, Zhizhan

    2016-07-01

    Inverse Compton scattering between ultra-relativistic electrons and an intense laser field has been proposed as a major route to generate compact high-brightness and high-energy γ-rays. Attributed to the inherent synchronization mechanism, an all-optical Compton scattering γ-ray source, using one laser to both accelerate electrons and scatter via the reflection of a plasma mirror, has been demonstrated in proof-of-principle experiments to produce a x-ray source near 100 keV. Here, by designing a cascaded laser wakefield accelerator to generate high-quality monoenergetic e-beams, which are bound to head-on collide with the intense driving laser pulse via the reflection of a 20-um-thick Ti foil, we produce tunable quasi-monochromatic MeV γ-rays (33% full-width at half-maximum) with a peak brilliance of ~3 × 1022 photons s-1 mm-2 mrad-2 0.1% BW at 1 MeV. To the best of our knowledge, it is one order of magnitude higher than ever reported value of its kinds in MeV regime. This compact ultrahigh brilliance γ-ray source may provide applications in nuclear resonance fluorescence, x-ray radiology and ultrafast pump-probe nondestructive inspection.

  6. Three-dimensional dispersion of spin waves measured in NiO by resonant inelastic x-ray scattering

    Science.gov (United States)

    Betto, D.; Peng, Y. Y.; Porter, S. B.; Berti, G.; Calloni, A.; Ghiringhelli, G.; Brookes, N. B.

    2017-07-01

    We used resonant inelastic x-ray scattering (RIXS) at the Ni L3 edge to measure the dispersion of spin waves in NiO thin films along the [101], [001], and [111] directions. Samples with tensile and compressive in-plane strain show identical dispersion within the experimental uncertainty. The fitting of the data with a linear spin wave model applied to a three-dimensional Heisenberg antiferromagnetic lattice provides a leading superexchange parameter J'=18 meV . The magnon energy at the Brillouin zone boundary and the value of J' are 5 % smaller than those determined by inelastic neutron scattering on bulk single crystals. This discrepancy is likely induced by the strain or other structural differences between bulk and epitaxially grown samples. These results demonstrate the capabilities of high-resolution RIXS in the study of the magnetic structure of thin films and heterostructures for which neutron scattering is not sensitive enough.

  7. High-pressure X-ray diffraction and Raman scattering of LiTaO sub 3

    CERN Document Server

    Zhang Wei; Pan Yue Wu; Dong Shu Shan; Zou Guang Tian; Liu Jing

    2002-01-01

    The authors study the energy-dispersive x-ray diffraction and Raman scattering of LiTaO sub 3 at high pressure. The result remains stable up to 36 GPa. The average isothermal bulk modulus and its pressure derivative are obtained to be k sub 0 =(225 +- 6) GPa and k sub 0 '=1.3 +- 0.5 at zero pressure by the Birch-Murnaghan equation of state and the 'universal' equation of state. The linear incompressibility of LiTaO sub 3 between the a- and c-directions differs by a factor of four, which shows that the compression is anisotropic

  8. X-ray diffraction and scattering studies of coal constituents. Final technical report, January 1-December 31, 1983

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovic, A. S.; Renton, J. T.

    1984-03-15

    The general objective of this work has been to use x-ray diffraction and scattering to examine whole coals, coal macerals and minerals in order to perform the following studies: (1) to identify and explain differences in vitrinites and framboids from various coals; (2) to correlate differences with basic coal compositions and properties; and (3) to determine the systematic variability in the micro compositional variation of macerals. The accomplishments have been: (a) the development of the Fourier transform technique to do proximate and ultimate analyses in a quick fashion; and (b) the investigation of the structure of pyrite framboids and preliminary studies of coal macerals. 3 figures, 12 tables.

  9. Nonequilibrium lattice-driven dynamics of stripes in nickelates using time-resolved x-ray scattering

    Science.gov (United States)

    Lee, W. S.; Kung, Y. F.; Moritz, B.; Coslovich, G.; Kaindl, R. A.; Chuang, Y. D.; Moore, R. G.; Lu, D. H.; Kirchmann, P. S.; Robinson, J. S.; Minitti, M. P.; Dakovski, G.; Schlotter, W. F.; Turner, J. J.; Gerber, S.; Sasagawa, T.; Hussain, Z.; Shen, Z. X.; Devereaux, T. P.

    2017-03-01

    We investigate the lattice coupling to the spin and charge orders in the striped nickelate, La1.75Sr0.25NiO4 , using time-resolved resonant x-ray scattering. Lattice-driven dynamics of both spin and charge orders are observed when the pump photon energy is tuned to that of an Eu bond- stretching phonon. We present a likely scenario for the behavior of the spin and charge order parameters and its implications using a Ginzburg-Landau theory.

  10. Nonequilibrium lattice-driven dynamics of stripes in nickelates using time-resolved x-ray scattering

    OpenAIRE

    Lee, WS; Kung, YF; Moritz, B.; Coslovich, G.; Kaindl, RA; Chuang, YD; Moore, RG; Lu, DH; Kirchmann, PS; Robinson, JS; Minitti, MP; Dakovski, G.; Schlotter, WF; Turner, JJ; Gerber, S

    2017-01-01

    © 2017 American Physical Society. We investigate the lattice coupling to the spin and charge orders in the striped nickelate, La1.75Sr0.25NiO4, using time-resolved resonant x-ray scattering. Lattice-driven dynamics of both spin and charge orders are observed when the pump photon energy is tuned to that of an Eu bond- stretching phonon. We present a likely scenario for the behavior of the spin and charge order parameters and its implications using a Ginzburg-Landau theory.

  11. Lattice dynamics of Al-based quasicrystals studied by high-resolution inelastic X-ray scattering with synchrotron radiation

    CERN Document Server

    Burkel, E; Ponkratz, U; Sinn, H; Alatas, A; Alp, E E

    2003-01-01

    Quasicrystals are aperiodic long-range ordered solids expected to exhibit peculiar dynamical properties. For these new intermetallic phases, previous theoretical work predicted the existence of phason dynamics and a highly structured vibrational density of states. We used the high-resolution inelastic X-ray scattering method to investigate the lattice dynamics of Al-Cu-Fe and Al-Pd-Mn quasicrystals, near the (18,29) diffraction peak situated on the fivefold axis. Phonon dispersion relations were determined for both quasicrystals. In addition to propagating acoustic modes, dispersionless ('optic') low-energy modes were observed.

  12. Nonequilibrium lattice-driven dynamics of stripes in nickelates using time-resolved x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.S.; Kung, Y.F.; Moritz, B.; Coslovich, G.; Kaindl, R.A.; Chuang, Y.D.; Moore, R.G.; Lu, D.H.; Kirchmann, P.S.; Robinson, J.S.; Minitti, M.P.; Dakovski, G.; Schlotter, W.F.; Turner, J.J.; Gerber, S.; Sasagawa, T.; Hussain, Z.; Shen, Z.X.; Devereaux, T.P.

    2017-03-13

    We investigate the lattice coupling to the spin and charge orders in the striped nickelate, La 1.75 Sr 0.25 NiO 4 , using time-resolved resonant x-ray scattering. Lattice-driven dynamics of both spin and charge orders are observed when the pump photon energy is tuned to that of an E u bond- stretching phonon. We present a likely scenario for the behavior of the spin and charge order parameters and its implications using a Ginzburg-Landau theory.

  13. Antibodies under pressure: A Small-Angle X-ray Scattering study of Immunoglobulin G under high hydrostatic pressure.

    Science.gov (United States)

    König, Nico; Paulus, Michael; Julius, Karin; Schulze, Julian; Voetz, Matthias; Tolan, Metin

    2017-05-26

    In the present work two subclasses of the human antibody Immunoglobulin G (IgG) have been investigated by Small-Angle X-ray Scattering under high hydrostatic pressures up to 5kbar. It is shown that IgG adopts a symmetric T-shape in solution which differs significantly from available crystal structures. Moreover, high-pressure experiments verify the high stability of the IgG molecule. It is not unfolded by hydrostatic pressures of up to 5kbar but a slight increase of the radius of gyration was observed at elevated pressures. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. X-ray Scattering Study of Early Stage Spinodal Decomposition in Al0.62Zn0.38

    Science.gov (United States)

    Mainville, J.; Yang, Y. S.; Elder, K. R.; Sutton, M.; Ludwig, K. F., Jr.; Stephenson, G. B.

    1997-04-01

    In situ small-angle x-ray scattering studies of the spinodal decomposition kinetics in an AlZn alloy at the critical composition have been performed with a time resolution of 10 ms. The kinetics of fluctuation relaxation above the critical point merges smoothly with the early-stage kinetics of fluctuation growth below Tc. Strong nonlinearities are present at the earliest times measured, even above the critical point. The nonlinear theory of Langer, Bar-on, and Miller [Phys. Rev. A 11, 1417 (1975)] quantitatively fits the data with reasonable thermodynamic and transport parameters.

  15. pH-Responsive Structural Change of PEGylated Amine-Bearing Nanogel Explored by Small Angle X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Goshu; Shinohara, Yuya; Amemiya, Yoshiyuki [Department of Advanced Materials Science, Graduate School of Frontier Sciences, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Akiba, Isamu; Sakurai, Kazuo [Department of Chemistry and Biochemistry, University of Kitakyushu (Japan); Tamura, Atsushi; Oishi, Motoi; Nagasaki, Yukio, E-mail: goshu@x-ray.k.u-tokyo.ac.jp [Department of Materials Science, Graduated School of Pure and Applied Science, University of Tsukuba (Japan)

    2011-01-01

    A PEGylated nanogel sphere containing cross-linked amino groups in its core undergoes dramatic volumetric changes upon pH-change. We measured small angle x-ray scattering from the nanogel and analyzed the data with a core-shell sphere model to determine the core size upon pH-change from 8.0 to 5.8. The protonation of the poly-amine core due to the pH-change increased the core volume by over 300%. Combining the obtained core volume and the absolute intensity, we estimated the change of the core electron density.

  16. Lateral structural variations in thin cellulose layers investigated by microbeam grazing incidence small-angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Roth, S.V. [HASYLAB at DESY, Notkestr. 85, D-22603 Hamburg (Germany)]. E-mail: sroth@esrf.fr; Artus, G.R.J. [Phys.-Chem. Inst., Univ. Zurich, Winterthurerstr. 190, CH-8057 Zurich (Switzerland); Rankl, M. [Phys.-Chem. Inst., Univ. Zurich, Winterthurerstr. 190, CH-8057 Zurich (Switzerland); Seeger, S. [Phys.-Chem. Inst., Univ. Zurich, Winterthurerstr. 190, CH-8057 Zurich (Switzerland); Burghammer, M. [ESRF, B.P. 220, F-38043 Grenoble Cedex 9 (France); Riekel, C. [ESRF, B.P. 220, F-38043 Grenoble Cedex 9 (France); Mueller-Buschbaum, P. [TU Muenchen, Phy.-Dept. E13, James-Franck-Str.1, D-85748 Garching (Germany)

    2005-02-28

    The Langmuir-Blodgett technique is a powerful tool to obtain large-scale thin films. We investigate a thin layer of modified cellulose by atomic force microscopy and microbeam grazing-incidence small angle X-ray scattering. We probe the lateral nanostructure of the as-prepared cellulose layer. The results indicate a lateral structural variation in the arrangement of the cellulose molecules parallel to the dipping direction. These variations occur on a length scale on the order of 100{mu}m.

  17. Electropolymerized nanoporous polymeric SPME coatings: preparation and characterization by small angle X-ray scattering and scanning electron microscopy.

    Science.gov (United States)

    Buszewski, Boguslaw; Olszowy, Pawel; Pikus, Stanislaw; Kozak, Maciej

    Polymeric polypyrrole and polythiophene solid phase microextraction (SPME) coatings were prepared using electropolymerization with a linear sweep voltammetry technique. Physicochemical properties were measured using different methods, in particular small angle X-ray scattering and scanning electron microscopy. By using innovative approaches for pore size measurement, we were able to calculate a maximum of the pore size range from 80 to 90 nm. Additionally, film thicknesses measured from 90 to 150 μm. Using scanning electron microscopy, we describe the characteristics of polymer growth on the support surface.

  18. Resonant inelastic scattering in dilute magnetic semiconductors by x-ray fluorescence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lawniczak-Jablonska, K. [Lawrence Berkeley National Lab., CA (United States)]|[Institute of Physics, Warsaw (Poland); Jia, J.J.; Underwood, J.H. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    As modern, technologically important materials have become more complex, element specific techniques have become invaluable in studying the electronic structure of individual components from the system. Soft x-ray fluorescence (SXF) and absorption (SXA) spectroscopies provide a unique means of measuring element and angular momentum density of electron states, respectively, for the valence and conducting bands in complex materials. X-ray absorption and the decay through x-ray emission are generally assumed to be two independent one-photon processes. Recent studies, however have demonstrated that SXF excited near the absorption threshold generate an array of spectral features that depend on nature of materials, particularly on the localization of excited states in s and d-band solids and that these two processes can no be longer treated as independent. Resonant SXF offers thus the new way to study the dynamics of the distribution of electronic valence states in the presence of a hole which is bound to the electron low lying in the conduction band. This process can simulate the interaction between hole-electron pair in wide gap semiconductors. Therefore such studies can help in understanding of transport and optics phenomena in the wide gap semiconductors. The authors report the result of Mn and S L-resonant emission in Zn{sub 1{minus}x}Mn{sub x}S (with x=0.2 and 0.3) and MnS as the energy of exciting radiation is tuned across the Mn and S L{sub 3,2} absorption edge, along with the resonant excited spectra from elemental Mn as a reference.

  19. Characterisation of cellulose- and lignin-based materials using x-ray scattering methods

    OpenAIRE

    Vainio, Ulla

    2007-01-01

    Wood is an important material for the construction and pulping industries. Using x-ray diffraction the microfibril angle of Sitka spruce wood was studied in the first part of this thesis. Sitka spruce (Picea sitchensis [Bong.] Carr.) is native to the west coast of North America, but due to its fast growth rate, it has also been imported to Europe. So far, its nanometre scale properties have not been systematically characterised. In this thesis the microfibril angle of Sitka spruce was shown t...

  20. X-ray Diffraction and Neutron Scattering Analysis of Natural and Synthetic Spider Silk Fibers

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Randolph [Utah State Univ., Logan, UT (United States)

    2013-11-11

    Spider silks have the potential to provide new bio-inspired materials for numerous applications in bioenergetics and products ranging from protective clothing to artificial ligaments and tendons. A number of spider silk genes have been cloned and sequenced by the Lewis laboratory revealing the basis for understanding the key elements of spider silk proteins with respect to their materials performance. In particular, specific amino acid motifs have been identified which have been conserved for over 125 million years in all spiders that use their silk to physically trap prey. The key element in taking the next step toward generating bio-based materials from spider silks will be to move from the current descriptive data to predictive knowledge. Current efforts are focused on mimicking spider silk through synthetic proteins. In developing synthetic silk fibers, we first need to understand the complete secondary and tertiary structure of natural silk so that we can compare synthetic constructs to the natural material. Being able to compare the structure on a single fiber level is critical to the future of molecular directed mimic development because we can vary mechanical properties by different spinning methods. The new generation of synchrotron x-ray diffraction and neutron beamlines will allow, for the first time, determination of the molecular structure of silk fibers and synthetic mimics. We propose an exciting new collaborative research team working jointly between Argonne National Laboratory, Arizona State U. and the University of Wyoming to address the ?characterization of synthetic and natural spider silk fibers using x-ray and neutron diffraction.? Thus these new methodologies will provide understanding of current fibers and determine changes needed to produce fibers with specific properties. The following specific aims are proposed: ? Synthesize spider silk fibers with molecular structures mimicking that of natural silks. Test the mechanic properties of these

  1. Dichroic interference effects in circularly polarized soft-x-ray resonant magnetic scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kao, C. (National Synchrotron Light Source, Brookhaven National Laboratory, Upton, New York 11973 (United States)); Chen, C.T. (AT T Bell Laboratories, Murray Hill, New Jersey 07974 (United States)); Johnson, E.D.; Hastings, J.B. (National Synchrotron Light Source, Brookhaven National Laboratory, Upton, New York 11973 (United States)); Lin, H.J. (AT T Bell Laboratories, Murray Hill, New Jersey 07974 (United States)); Ho, G.H. (Department of Physics, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)); Meigs, G. (AT T Bell Laboratories, Murray Hill, New Jersey 07974 (United States)); Brot, J.; Hulbert, S.L. (National Synchrotron Light Source, Brookhaven National Laboratory, Upton, New York 11973 (United States)); Idzerda, Y.U. (Naval Research Laboratory, Washington, D.C. 20375 (United States)); Vettier, C. (European Synchrotron Radiation Facility, BP220, F-38043 Grenoble CEDEX (France))

    1994-10-01

    Dichroic interference effects were observed in circularly polarized soft-x-ray reflectivity at the Co [ital L][sub 2,3] edges of a magnetic multilayer. The data show a maximum asymmetry ratio of 80%, greater than the degree of circular polarization of the incident light, a changeover in the dichroic characteristics with increasing grazing angle, and an inverted interference pattern in the angular dependence of the asymmetry ratio. These observations are explained successfully by a classical electromagnetic model calculation which includes the complete polarization state of the incident light and spatial interference within the multilayer.

  2. Spherical analyzers and monochromators for resonant inelastic hard X-ray scattering: a compilation of crystals and reflections

    Energy Technology Data Exchange (ETDEWEB)

    Gog, Thomas, E-mail: gog@aps.anl.gov; Casa, Diego M.; Said, Ayman H.; Upton, Mary H.; Kim, Jungho; Kuzmenko, Ivan; Huang, XianRong; Khachatryan, Ruben [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)

    2013-01-01

    Resonant inelastic X-ray scattering (RIXS) experiments require special sets of near-backscattering spherical diced analyzers and high-resolution monochromators for every distinct absorption-edge energy or emission line. For the purpose of aiding the design and planning of efficient RIXS experiments, a compilation of suitable crystal materials and viable reflections for hard X-rays, together with energy resolution and throughput information, is presented. Resonant inelastic X-ray scattering (RIXS) experiments require special sets of near-backscattering spherical diced analyzers and high-resolution monochromators for every distinct absorption-edge energy and emission line. For the purpose of aiding the design and planning of efficient RIXS experiments, comprehensive lists of suitable analyzer reflections for silicon, germanium, α-quartz, sapphire and lithium niobate crystals were compiled for a multitude of absorption edges and emission lines. Analyzers made from lithium niobate, sapphire or α-quartz offer many choices of reflections with intrinsic resolutions currently unattainable from silicon or germanium. In some cases these materials offer higher intensities at comparable resolutions. While lithium niobate, sapphire or α-quartz analyzers are still in an early stage of development, the present compilation can serve as a computational basis for assessing expected and actual performance. With regard to high-resolution monochromators, bandpass and throughput calculations for combinations of double-crystal, high-heat-load and near-backscattering high-resolution channel-cuts were assembled. The compilation of these analyzer and monochromator data is publicly available on a website.

  3. Accurate small and wide angle x-ray scattering profiles from atomic models of proteins and nucleic acids

    Science.gov (United States)

    Nguyen, Hung T.; Pabit, Suzette A.; Meisburger, Steve P.; Pollack, Lois; Case, David A.

    2014-12-01

    A new method is introduced to compute X-ray solution scattering profiles from atomic models of macromolecules. The three-dimensional version of the Reference Interaction Site Model (RISM) from liquid-state statistical mechanics is employed to compute the solvent distribution around the solute, including both water and ions. X-ray scattering profiles are computed from this distribution together with the solute geometry. We describe an efficient procedure for performing this calculation employing a Lebedev grid for the angular averaging. The intensity profiles (which involve no adjustable parameters) match experiment and molecular dynamics simulations up to wide angle for two proteins (lysozyme and myoglobin) in water, as well as the small-angle profiles for a dozen biomolecules taken from the BioIsis.net database. The RISM model is especially well-suited for studies of nucleic acids in salt solution. Use of fiber-diffraction models for the structure of duplex DNA in solution yields close agreement with the observed scattering profiles in both the small and wide angle scattering (SAXS and WAXS) regimes. In addition, computed profiles of anomalous SAXS signals (for Rb+ and Sr2+) emphasize the ionic contribution to scattering and are in reasonable agreement with experiment. In cases where an absolute calibration of the experimental data at q = 0 is available, one can extract a count of the excess number of waters and ions; computed values depend on the closure that is assumed in the solution of the Ornstein-Zernike equations, with results from the Kovalenko-Hirata closure being closest to experiment for the cases studied here.

  4. Accurate small and wide angle x-ray scattering profiles from atomic models of proteins and nucleic acids.

    Science.gov (United States)

    Nguyen, Hung T; Pabit, Suzette A; Meisburger, Steve P; Pollack, Lois; Case, David A

    2014-12-14

    A new method is introduced to compute X-ray solution scattering profiles from atomic models of macromolecules. The three-dimensional version of the Reference Interaction Site Model (RISM) from liquid-state statistical mechanics is employed to compute the solvent distribution around the solute, including both water and ions. X-ray scattering profiles are computed from this distribution together with the solute geometry. We describe an efficient procedure for performing this calculation employing a Lebedev grid for the angular averaging. The intensity profiles (which involve no adjustable parameters) match experiment and molecular dynamics simulations up to wide angle for two proteins (lysozyme and myoglobin) in water, as well as the small-angle profiles for a dozen biomolecules taken from the BioIsis.net database. The RISM model is especially well-suited for studies of nucleic acids in salt solution. Use of fiber-diffraction models for the structure of duplex DNA in solution yields close agreement with the observed scattering profiles in both the small and wide angle scattering (SAXS and WAXS) regimes. In addition, computed profiles of anomalous SAXS signals (for Rb(+) and Sr(2+)) emphasize the ionic contribution to scattering and are in reasonable agreement with experiment. In cases where an absolute calibration of the experimental data at q = 0 is available, one can extract a count of the excess number of waters and ions; computed values depend on the closure that is assumed in the solution of the Ornstein-Zernike equations, with results from the Kovalenko-Hirata closure being closest to experiment for the cases studied here.

  5. Ultrabright x-ray laser scattering for dynamic warm dense matter physics

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, L. B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Univ. of California, Berkeley, CA (United States); Lee, H. J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Doppner, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Galtier, E. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Nagler, B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Heimann, P. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Fortmann, C. [QuantumWise A/S, Koebenhavn (Denmark); LePape, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mao, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Millot, M. [Univ. of California, Berkeley, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pak, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Turnbull, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chapman, D. A. [AWE plc, Reading (United Kingdom); Univ. of Warwick, Coventry (United Kingdom); Gericke, D. O. [AWE plc, Reading (United Kingdom); Vorberger, J. [Max Planck Institute for the Physics of Complex Systems, Dresden (Germany); White, T. [Univ. of Oxford, Oxford (United Kingdom); Gregori, G. [Univ. of Oxford, Oxford (United Kingdom); Wei, M. [General Atomics, San Diego, CA (United States); Barbrel, B. [Univ. of California, Berkeley, CA (United States); Falcone, R. W. [Univ. of California, Berkeley, CA (United States); Kao, C. -C. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Nuhn, H. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Welch, J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Zastrau, U. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Friedrich-Schiller-Univ., Jena (Germany); Neumayer, P. [GSI Helmhltzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Hastings, J. B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Glenzer, S. H. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-03-23

    In megabar shock waves, materials compress and undergo a phase transition to a dense charged-particle system that is dominated by strong correlations and quantum effects. This complex state, known as warm dense matter, exists in planetary interiors and many laboratory experiments (for example, during high-power laser interactions with solids or the compression phase of inertial confinement fusion implosions). Here, we apply record peak brightness X-rays at the Linac Coherent Light Source to resolve ionic interactions at atomic (ångström) scale lengths and to determine their physical properties. Our in situ measurements characterize the compressed lattice and resolve the transition to warm dense matter, demonstrating that short-range repulsion between ions must be accounted for to obtain accurate structure factor and equation of state data. Additionally, the unique properties of the X-ray laser provide plasmon spectra that yield the temperature and density with unprecedented precision at micrometre-scale resolution in dynamic compression experiments.

  6. Determination of uranyl incorporation into biogenic manganese oxides using X-ray absorption spectroscopy and scattering

    Science.gov (United States)

    Webb, S.M.; Fuller, C.C.; Tebo, B.M.; Bargar, J.R.

    2006-01-01

    Biogenic manganese oxides are common and an important source of reactive mineral surfaces in the environment that may be potentially enhanced in bioremediation cases to improve natural attenuation. Experiments were performed in which the uranyl ion, UO22+ (U(VI)), at various concentrations was present during manganese oxide biogenesis. At all concentrations, there was strong uptake of U onto the oxides. Synchrotron-based extended X-ray absorption fine structure (EXAFS) spectroscopy and X-ray diffraction (XRD) studies were carried out to determine the molecular-scale mechanism by which uranyl is incorporated into the oxide and how this incorporation affects the resulting manganese oxide structure and mineralogy. The EXAFS experiments show that at low concentrations (2 mol % U, >4 ??M U(VI) in solution), the presence of U(VI) affects the stability and structure of the Mn oxide to form poorly ordered Mn oxide tunnel structures, similar to todorokite. EXAFS modeling shows that uranyl is present in these oxides predominantly in the tunnels of the Mn oxide structure in a tridentate complex. Observations by XRD corroborate these results. Structural incorporation may lead to more stable U(VI) sequestration that may be suitable for remediation uses. These observations, combined with the very high uptake capacity of the Mn oxides, imply that Mn-oxidizing bacteria may significantly influence dissolved U(VI) concentrations in impacted waters via sorption and incorporation into Mn oxide biominerals. ?? 2006 American Chemical Society.

  7. Ultra-high Resolution Optics for EUV and Soft X-ray Inelastic Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Voronov, Dmitry L.; Cambie, Rossana; Ahn, Minseung; Anderson, Erik H.; Chang, Chih-Hao; Gullikson, Eric M.; Heilmann, Ralf K.; Salmassi, Farhad; Schattenburg, Mark L.; Yashchuk, Valeriy V.; Padmore, Howard A.

    2009-09-16

    We describe a revolutionary new approach to high spectral resolution soft x-ray optics. Conventionally in the soft x-ray energy range, high spectral resolution is obtained by use of a relatively low line density grating operated in 1st order with small slits. This severely limits throughput. This limitation can be removed by use of a grating either in very high order, or with very high line density, if one can maintain high diffraction efficiency. We have developed a new technology for achieving both of these goals which should allow high throughput spectroscopy, at resolving powers of up to 106 at 1 keV. Such optics should provide a revolutionary advance for high resolution lifetime free spectroscopy, such as RIXS, and for pulse compression of chirped beams. We report recent developmental fabrication and characterization of a prototype grating optimized for 14.2 nm EUV light. The prototype grating with a 200 nm period of the blazed grating substrate coated with 20 Mo/Si bilayers with a period of 7.1 nm demonstrates good dispersion in the third order (effective groove density of 15,000 lines per mm) with a diffraction efficiency of more than 33percent.

  8. Imaging ultrafast excited state pathways in transition metal complexes by X-ray transient absorption and scattering using X-ray free electron laser source

    DEFF Research Database (Denmark)

    Chen, Lin X; Shelby, Megan L; Lestrange, Patrick J

    2016-01-01

    This report will describe our recent studies of transition metal complex structural dynamics on the fs and ps time scales using an X-ray free electron laser source, Linac Coherent Light Source (LCLS). Ultrafast XANES spectra at the Ni K-edge of nickel(ii) tetramesitylporphyrin (NiTMP) were measured...... on the low-energy shoulder of the edge, which is aided by the computation of X-ray transitions for postulated excited electronic states. The observed and computed inner shell to valence orbital transition energies demonstrate and quantify the influence of the electronic configuration on specific metal...... orbital energies. A strong influence of the valence orbital occupation on the inner shell orbital energies indicates that one should not use the transition energy from 1s to other orbitals to draw conclusions about the d-orbital energies. For photocatalysis, a transient electronic configuration could...

  9. Mineral crystal alignment in mineralized fracture callus determined by 3D small-angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yifei; Manjubala, Inderchand; Fratzl, Peter [Department of Biomaterials, Max Planck Institute of Colloids and Interfaces, 14424 Potsdam (Germany); Roschger, Paul [4th Medical Department, Ludwig Boltzmann Institute of Osteology at Hanusch Hospital of WGKK and AUVA Trauma Centre Meidling, 1140 Vienna (Austria); Schell, Hanna; Duda, Georg N, E-mail: fratzl@mpikg.mpg.d [Julius Wolff Institut and Center for Musculoskeletal Surgery, Charite- University Medicine Berlin, Augustenburger Platz 1, 13353 Berlin (Germany)

    2010-10-01

    Callus tissue formed during bone fracture healing is a mixture of different tissue types as revealed by histological analysis. But the structural characteristics of mineral crystals within the healing callus are not well known. Since two-dimensional (2D) scanning small-angle X-ray scattering (sSAXS) patterns showed that the size and orientation of callus crystals vary both spatially and temporally [1] and 2D electron microscopic analysis implies an anisotropic property of the callus morphology, the mineral crystals within the callus are also expected to vary in size and orientation in 3D. Three-dimensional small-angle X-ray scattering (3D SAXS), which combines 2D SAXS patterns collected at different angles of sample tilting, has been previously applied to investigate bone minerals in horse radius [2] and oim/oim mouse femur/tibia [3]. We implement a similar 3D SAXS method but with a different way of data analysis to gather information on the mineral alignment in fracture callus. With the proposed accurate yet fast assessment of 3D SAXS information, it was shown that the plate shaped mineral particles in the healing callus were aligned in groups with their predominant orientations occurring as a fiber texture.

  10. Microstructures of a Pt/Ni/C multilayer system: an X-ray reflectivity and ion scattering study.

    Science.gov (United States)

    Roy, Sumalay; Bera, S; Dev, B N

    2007-06-01

    Microstructural characterization of a synthetic periodic and graded Pt/Ni/C multilayer system by X-ray reflectivity and ion scattering techniques is presented. The experimental reflectivity data are fitted with a theoretical multi-trilayer model with graded periodicity which increases from substrate to film surface along the surface normal direction. The increase in periodicity is found to be due to a linear increase in C-layer thickness from the bottom to the top, with a change of slope nearly at the middle of the multilayer stack. The thicknesses of Pt and Ni layers, the variation of C-layer thickness with depth, interface roughness of Pt/Ni, Ni/C, C/Pt interfaces are determined from the analysis of the reflectivity data. Rutherford backscattering spectrometry measurements were also made on the same sample. Simulated Rutherford back scattering spectrometry data using the parameters obtained from the analysis of the X-ray reflectivity data agree well with the measured Rutherford backscattering spectrum.

  11. Characterization of pore structure in metal-organic framework by small-angle X-ray scattering.

    Science.gov (United States)

    Tsao, Cheng-Si; Yu, Ming-Sheng; Chung, Tsui-Yun; Wu, Hsiu-Chu; Wang, Cheng-Yu; Chang, Kuei-Sen; Chen, Hsin-Lung

    2007-12-26

    MOF-5-like crystals were studied by small-angle X-ray scattering (SAXS) to reveal, both quantitatively and qualitatively, their real structural details, including pore surface characteristics, pore shape, size distribution, specific surface area (SSA), spatial distribution, and pore-network structure. A combined SAXS and wide-angle X-ray scattering (WAXS) experiment was conducted to investigate the variation of the pore structure with the MOF-5 crystalline phase produced at different cooling rates. The SSA of the MOF-5 crystals synthesized herein spanned a broad range from approximately 3100 to 800 m2/g. The real pore structures were divided into two regimes. In regime I the material consisted mainly of micropores of radius approximately 8 A as well as mesopores of radius 120 approximately 80 A. The structure in regime II was a fractal network of aggregated mesopores with radius >or=32 A as the monomer, reducing SSA and hydrogen uptake capacity at room temperature. The two regimes can be manipulated by controlling the synthesis parameters. The concurrent evolution of pore structure and crystalline phase during heating for solvent removal was also revealed by the in-situ SAXS/WAXS measurement. The understanding of the impact of the real pore structure on the properties is important to establish a favorable synthetic approach for markedly improving the hydrogen storage capacity of MOF-5.

  12. Investigating the Effect of Adding Drug (Lidocaine) to a Drug Delivery System Using Small-Angle X-Ray Scattering

    Science.gov (United States)

    Balogh, Joakim; Pedersen, Jan Skov

    The effect on a model drug delivery system when adding a drug, lidocaine, has been studied. Temperature and concentration dependence of a nonionic microemulsion with part of the oil, 1 and %[vol.]10, substituted with drug has been investigated. A nonionic oil-in-water microemulsion consisting of CH3(CH2)11(OCH2CH2)5OH, (C12E5), decane, water and the drug (lidocaine) that has been used to substitute part of the oil was studied. The microscopic differences have been derived from small-angle X-ray scattering (SAXS) data and the results are compared with light scattering data. Using these results together with the macroscopic differences, as observed in the phase diagram (lowering of phase boundaries), between the systems with and without lidocaine can be explained.

  13. Time-Resolving Study of Stress-Induced Transformations of Isotactic Polypropylene through Wide Angle X-ray Scattering Measurements

    Directory of Open Access Journals (Sweden)

    Finizia Auriemma

    2018-02-01

    Full Text Available The development of a highly oriented fiber morphology by effect of tensile deformation of stereodefective isotactic polypropylene (iPP samples, starting from the unoriented γ form, is studied by following the transformation in real time during stretching through wide angle X-ray scattering (WAXS measurements. In the stretching process, after yielding, the initial γ form transforms into the mesomorphic form of iPP through mechanical melting and re-crystallization. The analysis of the scattering invariant measured in the WAXS region highlights that the size of the mesomorphic domains included in the well oriented fiber morphology obtained at high deformations increases through a process which involves the coalescence of the small fragments formed by effect of tensile stress during lamellar destruction with the domain of higher dimensions.

  14. Structure and kinetics of chemically cross-linked protein gels from small-angle X-ray scattering

    CERN Document Server

    Kaieda, Shuji; Halle, Bertil

    2014-01-01

    Glutaraldehyde (GA) reacts with amino groups in proteins, forming intermolecular cross-links that, at sufficiently high protein concentration, can transform a protein solution into a gel. Although GA has been used as a cross-linking reagent for decades, neither the cross-linking chemistry nor the microstructure of the resulting protein gel have been clearly established. Here we use small-angle X-ray scattering (SAXS) to characterise the microstructure and structural kinetics of gels formed by cross-linking of pancreatic trypsin inhibitor, myoglobin or intestinal fatty acid-binding protein. By comparing the scattering from gels and dilute solutions, we extract the structure factor and the pair correlation function of the gel. The protein gels are spatially heterogeneous, with dense clusters linked by sparse networks. Within the clusters, adjacent protein molecules are almost in contact, but the protein concentration in the cluster is much lower than in a crystal. At the $\\sim$ 1 nm SAXS resolution, the native ...

  15. Use of a solar panel as a directionally sensitive large-area radiation monitor for direct and scattered x-rays and gamma-rays.

    Science.gov (United States)

    Abdul-Majid, S

    1987-01-01

    The characteristics of a 25.4 X 91 cm solar cell panel used as an x-ray and gamma-ray radiation monitor are presented. Applications for monitoring the primary x-ray beam are described at different values of operating currents and voltages as well as for directional dependence of scattered radiation. Other applications in gamma-ray radiography are also given. The detector showed linear response to both x-ray and gamma-ray exposures. The equipment is rigid, easy to use, relatively inexpensive and requires no power supply or any complex electronic equipment.

  16. X-ray solution scattering of squid heavy meromyosin: strengthening the evidence for an ancient compact off state.

    Science.gov (United States)

    Gillilan, Richard E; Kumar, V S Senthil; O'Neall-Hennessey, Elizabeth; Cohen, Carolyn; Brown, Jerry H

    2013-01-01

    The overall conformations of regulated myosins or heavy meromyosins from chicken/turkey, scallop, tarantula, limulus, and scorpion sources have been studied by a number of techniques, including electron microscopy, sedimentation, and pulsed electron paramagnetic resonance. These studies have indicated that the binding of regulatory ions changes the conformation of the molecule from a compact shape found in the "off" state of the muscle to extended relationships between the tail and independently mobile heads that predominate in the "on" state. Here we strengthen the argument for the generality of this conformational change by using small angle X-ray scattering on heavy meromyosin from squid. Small angle X-ray scattering allows the protein to be visualized in solution under mild and relatively physiological conditions, and squid differs from the other species studied by at least 500 million years of evolution. Analysis of the data indicates that upon addition of Ca(2+) the radius of gyration increases. Differences in the squid "on" and "off" states are clearly distinguishable as bimodal and unimodal pair distance distribution functions respectively. These observations are consistent with a Ca(2+)-free squid heavy meromyosin that is compact, but which becomes extended when Ca(2+) is bound. Further, the scattering profile derived from the current model of tarantula heavy meromyosin in the "off" state is in excellent agreement with the measured "off" state scattering profile for squid heavy meromyosin. The previous and current studies together provide significant evidence that regulated myosin's compact off-state conformation is an ancient trait, inherited from a common ancestor during divergent evolution.

  17. Measuring warm dense matter properties with spectrally resolved x-ray scattering

    Science.gov (United States)

    Glenzer, Siegfried; X-ray Thomson Scattering Collaboration

    2017-10-01

    We have developed powerful ultrafast pump-probe techniques to measure the structural transformations and the physical properties of matter in extreme conditions. We apply megabar pressures to our samples using high-power laser irradiation followed by X-ray laser pulses from the Linac Coherent Light Source to take femtosecond measurements of the states that result. These experiments deliver data of unprecedented accuracy that allow critical experimental tests of theory in the challenging near-Fermi degenerate warm dense matter regime or in the non-ideal plasma state. We find good agreement with density functional theory simulations and provide predictions for new studies at the highest densities in laboratory plasmas that approach conditions of the interiors of brown dwarfs. This work is supported by DOE FES under FWP 100182.

  18. Phases of phosphatidyl ethanolamine monolayers studied by synchrotron x-ray scattering

    DEFF Research Database (Denmark)

    Helm, C.A.; Tippmann-Krayer, P.; Möhwald, H.

    1991-01-01

    For the first time, phospholid monolayers at the air/water interface have been studied by x-ray diffraction and reflection all along the isotherm from the laterally isotropic fluid (the so-called LE phase) to the ordered phases. The model used to analyze the data, and the accuracy of the parameters...... deduced, were tested by comparing the results obtained with two lipids having the same head group but different chain lengths. Compression of the fluid phase leads predominantly to a change of thickness of the hydrophobic moiety, much less of its density, with the head group extension remaining constant....... The main transition involves a considerable increase (approximately 10%) of the electron density in the hydrophobic region, a dehydration of the head group and a positional ordering of the aliphatic tails, albeit with low coherence lengths (approximately 10 spacings). On further compression of the film...

  19. Structure of PEP-PEO block copolymer micelles: Exploiting the complementarity of small-angle X-ray scattering and static light scattering

    DEFF Research Database (Denmark)

    Jensen, Grethe Vestergaard; Shi, Qing; Hernansanz, María J.

    2011-01-01

    . The present work shows that the same information can be obtained by combining static light scattering (SLS) and small-angle X-ray scattering (SAXS), which provide information on, respectively, large and short length scales. Micelles of a series of block copolymers of poly(ethylene propylene...... contrasts of the two components are very different, allowing for resolution of the internal micelle structure. A core-shell model with a PEP core and PEO corona is fitted simultaneously to the SAXS and SLS data using the different contrasts of the two blocks for each technique. With increasing PEO molecular...

  20. A hybrid approach to simulate multiple photon scattering in X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Freud, N. [CNDRI, Laboratory of Nondestructive Testing using Ionizing Radiations, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint-Exupery, 20, avenue Albert Einstein, 69621 Villeurbanne Cedex (France)]. E-mail: nicolas.freud@insa-lyon.fr; Letang, J.-M. [CNDRI, Laboratory of Nondestructive Testing using Ionizing Radiations, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint-Exupery, 20, avenue Albert Einstein, 69621 Villeurbanne Cedex (France); Babot, D. [CNDRI, Laboratory of Nondestructive Testing using Ionizing Radiations, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint-Exupery, 20, avenue Albert Einstein, 69621 Villeurbanne Cedex (France)

    2005-01-01

    A hybrid simulation approach is proposed to compute the contribution of scattered radiation in X- or {gamma}-ray imaging. This approach takes advantage of the complementarity between the deterministic and probabilistic simulation methods. The proposed hybrid method consists of two stages. Firstly, a set of scattering events occurring in the inspected object is determined by means of classical Monte Carlo simulation. Secondly, this set of scattering events is used as a starting point to compute the energy imparted to the detector, with a deterministic algorithm based on a 'forced detection' scheme. For each scattering event, the probability for the scattered photon to reach each pixel of the detector is calculated using well-known physical models (form factor and incoherent scattering function approximations, in the case of Rayleigh and Compton scattering respectively). The results of the proposed hybrid approach are compared to those obtained with the Monte Carlo method alone (Geant4 code) and found to be in excellent agreement. The convergence of the results when the number of scattering events increases is studied. The proposed hybrid approach makes it possible to simulate the contribution of each type (Compton or Rayleigh) and order of scattering, separately or together, with a single PC, within reasonable computation times (from minutes to hours, depending on the number of pixels of the detector). This constitutes a substantial benefit, compared to classical simulation methods (Monte Carlo or deterministic approaches), which usually requires a parallel computing architecture to obtain comparable results.

  1. Physical analysis of the shielding capacity for a lightweight apron designed for shielding low intensity scattering X-rays

    Science.gov (United States)

    Kim, Seon Chil; Choi, Jeong Ryeol; Jeon, Byeong Kyou

    2016-07-01

    The purpose of this paper is to develop a lightweight apron that will be used for shielding low intensity radiation in medical imaging radiography room and to apply it to a custom-made effective shielding. The quality of existing aprons made for protecting our bodies from direct radiation are improved so that they are suitable for scattered X-rays. Textiles that prevent bodies from radiation are made by combining barium sulfate and liquid silicon. These materials have the function of shielding radiation in a manner like lead. Three kinds of textiles are produced. The thicknesses of each textile are 0.15 mm, 0.21 mm, and 0.29 mm and the corresponding lead equivalents are 0.039 mmPb, 0.095 mmPb, 0.22 mmPb for each. The rate of shielding space scattering rays are 80% from the distance of 0.5 m, 86% from 1.0 m, and 97% from 1.5 m. If we intend to approach with the purpose of shielding scattering X-rays and low intensity radiations, it is possible to reduce the weight of the apron to be 1/5 compared to that of the existing lead aprons whose weight is typically more than 4 kg. We confirm, therefore, that it is possible to produce lightweight aprons that are used for the purpose of shielding low dose radiations.

  2. Nucleation and growth of gold nanoparticles studied via in situ small angle X-ray scattering at millisecond time resolution.

    Science.gov (United States)

    Polte, Jörg; Erler, Robert; Thünemann, Andreas F; Sokolov, Sergey; Ahner, T Torsten; Rademann, Klaus; Emmerling, Franziska; Kraehnert, Ralph

    2010-02-23

    Gold nanoparticles (AuNP) were prepared by the homogeneous mixing of continuous flows of an aqueous tetrachloroauric acid solution and a sodium borohydride solution applying a microstructured static mixer. The online characterization and screening of this fast process ( approximately 2 s) was enabled by coupling a micromixer operating in continuous-flow mode with a conventional in-house small angle X-ray scattering (SAXS) setup. This online characterization technique enables the time-resolved investigation of the growth process of the nanoparticles from an average radius of ca. 0.8 nm to about 2 nm. To the best of our knowledge, this is the first demonstration of a continuous-flow SAXS setup for time-resolved studies of nanoparticle formation mechanisms that does not require the use of synchrotron facilities. In combination with X-ray absorption near edge structure microscopy, scanning electron microscopy, and UV-vis spectroscopy the obtained data allow the deduction of a two-step mechanism of gold nanoparticle formation. The first step is a rapid conversion of the ionic gold precursor into metallic gold nuclei, followed by particle growth via coalescence of smaller entities. Consequently it could be shown that the studied synthesis serves as a model system for growth driven only by coalescence processes.

  3. Time-resolved Small Angle X-ray Scattering During the Formation of Detonation Nano-Carbon Condensates

    Science.gov (United States)

    Bagge-Hansen, Michael; Hammons, Josh; Nielsen, Mike; Lauderbach, Lisa; Hodgin, Ralph; Bastea, Sorin; van Buuren, Tony; Pagoria, Phil; May, Chadd; Jensen, Brian; Gustavsen, Rick; Watkins, Erik; Firestone, Millie; Dattelbaum, Dana; Fried, Larry; Cowan, Matt; Willey, Trevor

    2017-06-01

    Carbon nanomaterials are spontaneously generated under high pressure and temperature conditions present during the detonation of many high explosive (HE) materials. Thermochemical modeling suggests that the phase, size, and morphology of carbon condensates are strongly dependent on the type of HE used and associated evolution of temperature and pressure during the very early stages of detonation. Experimental validation of carbon condensation under these extreme conditions has been technically challenging. Here, we present synchrotron-based, time-resolved small-angle x-ray scattering (TR-SAXS) measurements collected during HE detonations, acquired from discrete sub-100 ps x-ray pulses, every 153.4 ns. We select from various HE materials and geometries to explore a range of achievable pressures and temperatures that span detonation conditions and, correspondingly, generate an array of nano-carbon products, including nano-diamonds and nano-onions. The TR-SAXS patterns evolve rapidly over the first few hundred nanoseconds. Comparing the results with modeling offers significant progress towards a general carbon equation of state. Prepared by LLNL under Contract DE-AC52-07NA27344.

  4. Two-temperature equilibration in warm dense hydrogen measured with x-ray scattering from the LCLS

    Science.gov (United States)

    Fletcher, Luke; High Energy Density Sciences Collaboration

    2017-10-01

    Understanding the properties of warm dense hydrogen plasmas is critical for modeling stellar and planetary interiors, as well as for inertial confinement fusion (ICF) experiments. Of central importance are the electron-ion collision and equilibration times that determine the microscopic properties in a high energy density state. Spectrally and angularly resolved x-ray scattering measurements from fs-laser heated hydrogen have resolved the picosecond evolution and energy relaxation from a two-temperature plasma towards thermodynamic equilibrium in the warm dense matter regime. The interaction of rapidly heated cryogenic hydrogen irradiated by a 400 nm, 5x1017 W/cm2 , 70 fs-laser is visualized with ultra-bright 5.5 kev x-ray pulses from the Linac Coherent Light (LCLS) source in 1 Hz repetition rate pump-probe setting. We demonstrate that the energy relaxation is faster than many classical binary collision theories that use ad hoc cutoff parameters used in the Landau-Spitzer determination of the Coulomb logarithm. This work was supported by the DOE Office of Science, Fusion Energy Science under contract No. SF00515 and supported under FWP 100182 and DOE Office of Basic Energy Sciences, Materials Sciences and Engineering Division, contract DE-AC02-76SF00515.

  5. Combined small angle X-ray solution scattering with atomic force microscopy for characterizing radiation damage on biological macromolecules.

    Science.gov (United States)

    Costa, Luca; Andriatis, Alexander; Brennich, Martha; Teulon, Jean-Marie; Chen, Shu-Wen W; Pellequer, Jean-Luc; Round, Adam

    2016-10-27

    Synchrotron radiation facilities are pillars of modern structural biology. Small-Angle X-ray scattering performed at synchrotron sources is often used to characterize the shape of biological macromolecules. A major challenge with high-energy X-ray beam on such macromolecules is the perturbation of sample due to radiation damage. By employing atomic force microscopy, another common technique to determine the shape of biological macromolecules when deposited on flat substrates, we present a protocol to evaluate and characterize consequences of radiation damage. It requires the acquisition of images of irradiated samples at the single molecule level in a timely manner while using minimal amounts of protein. The protocol has been tested on two different molecular systems: a large globular tetremeric enzyme (β-Amylase) and a rod-shape plant virus (tobacco mosaic virus). Radiation damage on the globular enzyme leads to an apparent increase in molecular sizes whereas the effect on the long virus is a breakage into smaller pieces resulting in a decrease of the average long-axis radius. These results show that radiation damage can appear in different forms and strongly support the need to check the effect of radiation damage at synchrotron sources using the presented protocol.

  6. The architecture of amyloid-like peptide fibrils revealed by X-ray scattering, diffraction and electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Langkilde, Annette E., E-mail: annette.langkilde@sund.ku.dk [University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen (Denmark); Morris, Kyle L.; Serpell, Louise C. [University of Sussex, Falmer, Brighton (United Kingdom); Svergun, Dmitri I. [European Molecular Biology Laboratory, Hamburg Outstation, 22607 Hamburg (Germany); Vestergaard, Bente [University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen (Denmark)

    2015-04-01

    The aggregation process and the fibril state of an amyloidogenic peptide suggest monomer addition to be the prevailing mechanism of elongation and a model of the peptide packing in the fibrils has been obtained. Structural analysis of protein fibrillation is inherently challenging. Given the crucial role of fibrils in amyloid diseases, method advancement is urgently needed. A hybrid modelling approach is presented enabling detailed analysis of a highly ordered and hierarchically organized fibril of the GNNQQNY peptide fragment of a yeast prion protein. Data from small-angle X-ray solution scattering, fibre diffraction and electron microscopy are combined with existing high-resolution X-ray crystallographic structures to investigate the fibrillation process and the hierarchical fibril structure of the peptide fragment. The elongation of these fibrils proceeds without the accumulation of any detectable amount of intermediate oligomeric species, as is otherwise reported for, for example, glucagon, insulin and α-synuclein. Ribbons constituted of linearly arranged protofilaments are formed. An additional hierarchical layer is generated via the pairing of ribbons during fibril maturation. Based on the complementary data, a quasi-atomic resolution model of the protofilament peptide arrangement is suggested. The peptide structure appears in a β-sheet arrangement reminiscent of the β-zipper structures evident from high-resolution crystal structures, with specific differences in the relative peptide orientation. The complexity of protein fibrillation and structure emphasizes the need to use multiple complementary methods.

  7. Intrinsic flexibility of West Nile virus protease in solution characterized using small-angle X-ray scattering.

    Science.gov (United States)

    Garces, Andrea P; Watowich, Stanley J

    2013-10-01

    West Nile virus (WNV) is a mosquito-borne flavivirus with a rapidly expanding global distribution. Infection can cause severe neurological disease and fatality in humans. Efforts are ongoing to develop antiviral drugs that inhibit the WNV protease, a viral enzyme required for polyprotein processing. Unfortunately, little is known about the solution structure of recombinant WNV protease (NS2B-NS3pro) used for antiviral drug discovery and development, although X-ray crystal structures and nuclear magnetic resonance (NMR) studies have provided valuable insights into the interactions between NS2B-NS3pro and peptide-based inhibitors. We completed small-angle X-ray scattering and Fourier transform infrared spectroscopy experiments to determine the solution structure and dynamics of WNV NS2B-NS3pro in the absence of a bound substrate or inhibitor. Importantly, these solution studies suggested that all or most of the NS2B cofactor was highly flexible and formed an ensemble of structures, in contrast to the NS2B tertiary structures observed in crystallographic and NMR studies. The secondary structure of NS2B-NS3pro in solution had high β-content, similar to the secondary structure observed in crystallographic studies. This work provided evidence of the intrinsic flexibility and conformational heterogeneity of the NS2B chain of the WNV protease in the absence of substratelike ligands, which should be considered during antiviral drug discovery and development efforts.

  8. Silicon nanocrystals with high boron and phosphorus concentration hydrophilic shell—Raman scattering and X-ray photoelectron spectroscopic studies

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Minoru, E-mail: fujii@eedept.kobe-u.ac.jp; Sugimoto, Hiroshi; Hasegawa, Masataka; Imakita, Kenji [Department of Electrical and Electronic Engineering, Graduate School of Engineering, Kobe University, Rokkodai, Nada, Kobe 657-8501 (Japan)

    2014-02-28

    Boron (B) and phosphorus (P) codoped silicon (Si) nanocrystals, which exhibit very wide range tunable luminescence due to the donor to acceptor transitions and can be dispersed in polar liquids without organic ligands, are studied by Raman scattering and X-ray photoelectron spectroscopies. Codoped Si nanocrystals exhibit a Raman spectrum significantly different from those of intrinsic ones. First, the Raman peak energy is almost insensitive to the size and is very close to that of bulk Si crystal in the diameter range of 2.7 to 14 nm. Second, the peak is much broader than that of intrinsic ones. Furthermore, an additional broad peak, the intensity of which is about 20% of the main peak, appears around 650 cm{sup −1}. The peak can be assigned to local vibrational modes of substitutional B and B-P pairs, B clusters, B-interstitial clusters, etc. in Si crystal. The Raman and X-ray photoelectron spectroscopic studies suggest that a crystalline shell heavily doped with these species is formed at the surface of a codoped Si nanocrystal and it induces the specific properties, i.e., hydrophilicity, high-stability in water, high resistance to hydrofluoric acid, etc.

  9. SU-E-I-64: X-Ray Coherent Scatter Mammography Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, L R; MacDonald, C A [University at Albany, SUNY, Albany, NY (United States)

    2014-06-01

    Purpose: Conventional mammography has poor contrast between healthy and cancerous tissues due to the small difference in attenuation properties. Coherent scatter potentially provides more information because interference of coherently scattered radiation depends on the average intermolecular spacing, and can be used to characterize tissue types. However, typical coherent scatter analysis techniques are not compatible with rapid low dose screening modalities. Coherent scatter slot scan imaging is a novel imaging technique which provides new information with higher contrast. In this work a simulation was performed of coherent scatter slot scan imaging to assess its performance and provide system optimization. Methods: In coherent scatter imaging, the coherent scatter is exploited using a conventional slot scan mammography system with anti-scatter grids tilted at the characteristic angle of cancerous tissues. A Monte Carlo simulation was used to simulate the coherent scatter imaging. System optimization was performed across several parameters, including source voltage and filtration, tilt angle, source and grid distances, grid ratio, and shielding geometry. Results: The contrast was high and increased as the grid tilt angle was increased beyond the characteristic angle for the modeled carcinoma, and as the source voltage increased. Source filtration did not have a significant effect on contrast. Increasing grid ratio improved contrast at the expense of decreasing the signal to noise ratio (SNR). As the tumor size is decreased, additional shields to block the fat signal are necessary in order to detect the cancer signal. Conclusion: Coherent scatter analysis using a wide slot setup is promising as an enhancement for screening mammography. This work was supported by National Institutes of Health, # 7 R01EB009715.

  10. Exploration of Monoenergetic X-Ray Mammography with Syncrotron Radiation

    National Research Council Canada - National Science Library

    Johnston, Richard

    1998-01-01

    .... Specifically developed as part of our x-ray mammography program utilizing monochromatic x-rays from a synchrotron source, this technique has produced images of test objects and tissue whose contrast...

  11. Center for X-Ray Optics, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors.

  12. A new method for x-ray scatter correction: first assessment on a cone-beam CT experimental setup

    Energy Technology Data Exchange (ETDEWEB)

    Rinkel, J [CEA-LETI MINATEC, Division of Micro Technologies for Biology and Healthcare, 38054 Grenoble Cedex 09 (France); Gerfault, L [CEA-LETI MINATEC, Division of Micro Technologies for Biology and Healthcare, 38054 Grenoble Cedex 09 (France); Esteve, F [INSERM U647-RSRM, ESRF, BP200, 38043 Grenoble Cedex 09 (France); Dinten, J-M [CEA-LETI MINATEC, Division of Micro Technologies for Biology and Healthcare, 38054 Grenoble Cedex 09 (France)

    2007-08-07

    Cone-beam computed tomography (CBCT) enables three-dimensional imaging with isotropic resolution and a shorter acquisition time compared to a helical CT scanner. Because a larger object volume is exposed for each projection, scatter levels are much higher than in collimated fan-beam systems, resulting in cupping artifacts, streaks and quantification inaccuracies. In this paper, a general method to correct for scatter in CBCT, without supplementary on-line acquisition, is presented. This method is based on scatter calibration through off-line acquisition combined with on-line analytical transformation based on physical equations, to adapt calibration to the object observed. The method was tested on a PMMA phantom and on an anthropomorphic thorax phantom. The results were validated by comparison to simulation for the PMMA phantom and by comparison to scans obtained on a commercial multi-slice CT scanner for the thorax phantom. Finally, the improvements achieved with the new method were compared to those obtained using a standard beam-stop method. The new method provided results that closely agreed with the simulation and with the conventional CT scanner, eliminating cupping artifacts and significantly improving quantification. Compared to the beam-stop method, lower x-ray doses and shorter acquisition times were needed, both divided by a factor of 9 for the same scatter estimation accuracy.

  13. An energy dispersive x-ray scattering and molecular dynamics study of liquid dimethyl carbonate.

    Science.gov (United States)

    Gontrani, Lorenzo; Russina, Olga; Marincola, Flaminia Cesare; Caminiti, Ruggero

    2009-12-28

    In this work, we report on the first x-ray diffraction study on liquid dimethyl carbonate. Diffraction spectra were collected with an energy-dispersive instrument, whose wide Q-range allows the structure determination of weakly ordered systems (such as liquids). The structural correlation in this liquid ranges up to about 20 A. The observed patterns are interpreted with a structural model derived from classical molecular dynamics simulations. The simulations were run using OPLS force field, only slightly modified to restrain bond distances to the experimental values. The model structure function and radial distribution functions, averaged among the productive trajectory frames, are in very good agreement with the corresponding experimental ones. Molecular dynamics results show that the deviations from C(2v) cis-cis structure, predicted by ab initio calculations and observed by electron diffraction in the gas phase, are small. By analyzing the intra- and intermolecular pair distribution functions, it was possible to assign the peaks of the experimental radial distribution function to specific structural correlations, and to compute the different average intermolecular coordination numbers. The intermolecular methyl-carbonyl oxygen distance is thoroughly discussed to assess the presence of weak C-H...O hydrogen bonds.

  14. X-ray scattering from dislocation arrays in GaSb

    CERN Document Server

    Babkevich, A Y; Mason, N J; Weller, S; Stunault, A

    2002-01-01

    The structure of GaSb layers grown epitaxially on GaAs(001) substrates has been studied by high-resolution x-ray diffraction. The samples with thicknesses between 95 and 2845 A were grown in Oxford by metal-organic vapour phase epitaxy. The large lattice mismatch is largely relaxed by two intersecting regular arrays of 90 deg. dislocations along the [110] and [11-bar 0 ] directions. The density of the dislocations changes with the thickness but the dislocations remain localized at the interface and both the GaSb layers and GaAs substrates are distorted. The spacing between the dislocations in both the [110] and [11-bar 0 ] directions decreases while the relaxation increases as the layer thickness increases. We have found the spacing of the dislocations, relaxation and residual in-plane strain along the [110] and [11-bar 0 ] directions and showed a strong asymmetry in dislocation spacing and relaxation between the two directions. This is because adjacent left brace 110 right brace planes in the zincblende stru...

  15. Direct experimental determination of spiral spin structures via the dichroism extinction effect in resonant elastic soft x-ray scattering

    Science.gov (United States)

    Zhang, S. L.; van der Laan, G.; Hesjedal, T.

    2017-09-01

    Long-wavelength spin spiral structures are ubiquitous in a large variety of magnetic materials. The detailed magnetic structure can take many variations owing to their different physical origins. Therefore, the unambiguous structural determination is crucial for understanding these spin systems, though such a task is experimentally challenging. Here, we show that ordered spin spiral structures can be fully determined in a single measurement by dichroic resonant elastic x-ray scattering using circularly polarized light. It is found that at certain geometrical conditions, the circular dichroism of the diffraction vanishes completely, revealing a one-to-one correspondence with the spin structure. We demonstrate both theoretically and experimentally this experimental principle, which allows for unambiguous structure determination immediately from the measured signal, whereby no modeling-based data refinement is needed. This largely expands the capabilities of conventional magnetic characterization techniques.

  16. Degradation of spatial resolution in thin-foil x-ray microchemical analysis due to plural scattering of electrons

    Energy Technology Data Exchange (ETDEWEB)

    Twigg, Mark Erickson [Univ. of Illinois, Urbana-Champaign, IL (United States)

    1982-01-01

    A computer-based Monte Carlo simulation of incoherent plural scattering of electrons has been developed in order to estimate the broadening of an electron probe as it propagates through a solid. By applying this approach to modeling the spreading of a fine (50 A) probe focused on a thin foil in a scanning transmission electron microscope (STEM), we have estimated the spatial resolution of the compositional analysis obtainable using energy dispersive x-ray spectroscopy (EDS). Specifically, an attempt has been made to determine how the apparent microchemistry of a feature of finer dimensions than the broadened beam differs from the actual composition of the given feature. The apparent Ge concentration profile in the vicinity of a 200 A wide Ge platelet in a 5000 A thick Al foil was measured, using STEM and EDS, and compared with the profile predicted by Monte Carlo calculations. Results are presented and discussed.

  17. Synchrotron X-ray Scattering Analysis of the Interaction Between Corn Starch and an Exogenous Lipid During Hydrothermal Treatment

    Energy Technology Data Exchange (ETDEWEB)

    E Hernandez-Hernandez; C Avila-Orta; B Hsiao; j Castro-Rosas; J Gallegos-Infante; J Morales-Castro; L Ochoa-Martinez; C Gomez-Aldapa

    2011-12-31

    Lipids have an important effect on starch physicochemical properties. There exist few reports about the effect of exogenous lipids on native corn starch structural properties. In this work, a study of the morphological, structural and thermal properties of native corn starch with L-alpha-lysophosphatidylcholine (LPC, the main phospholipid in corn) was performed under an excess of water. Synchrotron radiation, in the form of real-time small and wide-angle X-ray scattering (SAXS/WAXS), was used in order to track structural changes in corn starch, in the presence of LPC during a heating process from 30 to 85 C. When adding LCP, water absorption decreased within starch granule amorphous regions during gelatinization. This is explained by crystallization of the amylose-LPC inclusion complex during gelatinization, which promotes starch granule thermal stability at up to 95 C. Finally, a conceptual model is proposed for explaining the formation mechanism of the starch-LPC complex.

  18. Inelastic X-ray Scattering Investigations of Lattice Dynamics in SmFeAsO1-xFy Superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Hill, J.P.; Le Tacon, M.; Forrest, T.R.; Ruegg, Ch.; Bosak, A.; Noffsinger, J.; Walters, A.C.; Toulemonde, P.; Palenzona, A.; Zhigadlo, N.D.; Karpinski, J.; Krisch, M.; McMorrow, D.F.

    2010-05-23

    We report measurements of the phonon density of states as measured with inelastic x-ray scattering in SmFeAsO{sub 1-x}F{sub y} powders. An unexpected strong renormalization of phonon branches around 23 meV is observed as fluorine is substituted for oxygen. Phonon dispersion measurements on SmFeAsO{sub 1-x}F{sub y} single crystals allow us to identify the 21 meV A{sub 1g} in-phase (Sm,As) and the 26 meV B{sub 1g} (Fe,O) modes to be responsible for this renormalization, and may reaveal unusual electron-phonon coupling through the spin channel in iron-based superconductors.

  19. Tracking the picosecond deactivation dynamics of a photoexcited iron carbene complex by time-resolved X-ray scattering

    DEFF Research Database (Denmark)

    Leshchev, Denis; Harlang, Tobias C. B.; Fredin, Lisa A.

    2018-01-01

    is ascribed to strong ligand field splitting provided by the NHC ligands that raises the energy levels of the metal centered (MC) states and therefore reduces the deactivation efficiency of MLCT states. Among currently known NHC systems, [Fe(btbip)2]2+ (btbip = 2,6-bis(3-tert-butyl-imidazol-1-ylidene......, we use time-resolved wide angle X-ray scattering (TRWAXS) aided by density functional theory (DFT) to investigate the molecular structure, energetics and lifetime of the high-energy MC state in the Fe-NHC complex  [Fe(btbip)2]2+ after excitation to the MLCT manifold. We identify it as a 260 ps metal...

  20. X-ray magnetic circular dichroism and small angle neutron scattering studies of thiol capped gold nanoparticles.

    Energy Technology Data Exchange (ETDEWEB)

    de la Venta, J.; Bouzas, V.; Pucci, A.; Laguna-Marco, M. A.; Haskel, D.; te Velthuis, S. G. E; Hoffmann, A.; Lal, J.; Bleuel, M.; Ruggeri, G.; de Julian Fernandez, C.; Garcia, M. A.; Univ.Complutense de Madrid; Inst. de Magnetismo Aplicado; Univ. of Pisa; Lab. di Magnetismo Molecolare

    2009-01-01

    X-ray magnetic circular dichroism (XMCD) and Small Angle Neutron Scattering (SANS) measurements were performed on thiol capped Au nanoparticles (NPs) embedded into polyethylene. An XMCD signal of 0.8 {center_dot} 10{sup -4} was found at the Au L{sub 3} edge of thiol capped Au NPs embedded in a polyethylene matrix for which Superconducting Quantum Interference Device (SQUID) magnetometry yielded a saturation magnetization, M{sub s}, of 0.06 emu/g{sub Au}. SANS measurements showed that the 3.2 nm average-diameter nanoparticles are 28% polydispersed, but no detectable SANS magnetic signal was found with the resolution and sensitivity accessible with the neutron experiment. A comparison with previous experiments carried out on Au NPs and multilayers, yield to different values between XMCD signals and magnetization measured by SQUID magnetometer. We discuss the origin of those differences.