WorldWideScience

Sample records for scatter radiation breast

  1. Scatter radiation in digital tomosynthesis of the breast

    International Nuclear Information System (INIS)

    Sechopoulos, Ioannis; Suryanarayanan, Sankararaman; Vedantham, Srinivasan; D'Orsi, Carl J.; Karellas, Andrew

    2007-01-01

    Digital tomosynthesis of the breast is being investigated as one possible solution to the problem of tissue superposition present in planar mammography. This imaging technique presents various advantages that would make it a feasible replacement for planar mammography, among them similar, if not lower, radiation glandular dose to the breast; implementation on conventional digital mammography technology via relatively simple modifications; and fast acquisition time. One significant problem that tomosynthesis of the breast must overcome, however, is the reduction of x-ray scatter inclusion in the projection images. In tomosynthesis, due to the projection geometry and radiation dose considerations, the use of an antiscatter grid presents several challenges. Therefore, the use of postacquisition software-based scatter reduction algorithms seems well justified, requiring a comprehensive evaluation of x-ray scatter content in the tomosynthesis projections. This study aims to gain insight into the behavior of x-ray scatter in tomosynthesis by characterizing the scatter point spread functions (PSFs) and the scatter to primary ratio (SPR) maps found in tomosynthesis of the breast. This characterization was performed using Monte Carlo simulations, based on the Geant4 toolkit, that simulate the conditions present in a digital tomosynthesis system, including the simulation of the compressed breast in both the cranio-caudal (CC) and the medio-lateral oblique (MLO) views. The variation of the scatter PSF with varying tomosynthesis projection angle, as well as the effects of varying breast glandular fraction and x-ray spectrum, was analyzed. The behavior of the SPR for different projection angle, breast size, thickness, glandular fraction, and x-ray spectrum was also analyzed, and computer fit equations for the magnitude of the SPR at the center of mass for both the CC and the MLO views were found. Within mammographic energies, the x-ray spectrum was found to have no appreciable

  2. Influence of X-ray scatter radiation on image quality in Digital Breast Tomosynthesis (DBT)

    International Nuclear Information System (INIS)

    Rodrigues, M.J.; Di Maria, S.; Baptista, M.; Belchior, A.; Afonso, J.; Venâncio, J.; Vaz, P.

    2017-01-01

    Digital breast tomosynthesis (DBT) is a quasi-three-dimensional imaging technique that was developed to solve the principal limitation of mammography, namely the overlapping tissue effect. This issue in standard mammography (SM) leads to two main problems: low sensitivity (difficulty to detect lesions) and low specificity (non-negligible percentage of false positives). Although DBT is now being introduced in clinical practice the features of this technique have not yet been fully and accurately assessed. Consequently, optimization studies in terms of choosing the most suitable parameters which maximize image quality according to the known limits of breast dosimetry are currently performing. In DBT, scatter radiation can lead to a loss of contrast and to an increase of image noise by reducing the signal-to-difference-noise ratio (SDNR) of a lesion. Moreover the use of an anti-scatter grid is a concern due to the low exposure of the photon flux available per projection. For this reason the main aim of this study was to analyze the influence of the scatter radiation on image quality and the dose delivered to the breast. In particular a detailed analysis of the scatter radiation on the optimal energy that maximizes the SDNR was performed for different monochromatic energies and voltages. To reach this objective the PenEasy Monte Carlo (MC) simulation tool imbedded in the general-purpose main program PENELOPE, was used. After a successful validation of the MC model with measurements, 2D projection images of primary, coherent and incoherent photons were obtained. For that, a homogeneous breast phantom (2, 4, 6, 8 cm) with 25%, 50% and 75% glandular compositions was used, including a 5 mm thick tumor. The images were generated for each monochromatic X-ray energies in the range from 16 keV to 32 keV. For each angular projection considered (25 angular projections covering an arc of 50°) the scatter-to-primary ratio (SPR), the mean glandular dose (MGD) and the signal

  3. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    Energy Technology Data Exchange (ETDEWEB)

    Klasic, B. [Hospital for pulmonary diseases, Zagreb (Croatia); Knezevic, Z.; Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Brnic, Z.; Novacic, K. [Merkur Univ. Hospital, Zagreb (Croatia)

    2006-07-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  4. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    International Nuclear Information System (INIS)

    Klasic, B.; Knezevic, Z.; Vekic, B.; Brnic, Z.; Novacic, K.

    2006-01-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  5. Influence of X-ray scatter radiation on image quality in Digital Breast Tomosynthesis (DBT)

    Science.gov (United States)

    Rodrigues, M. J.; Di Maria, S.; Baptista, M.; Belchior, A.; Afonso, J.; Venâncio, J.; Vaz, P.

    2017-11-01

    Digital breast tomosynthesis (DBT) is a quasi-three-dimensional imaging technique that was developed to solve the principal limitation of mammography, namely the overlapping tissue effect. This issue in standard mammography (SM) leads to two main problems: low sensitivity (difficulty to detect lesions) and low specificity (non-negligible percentage of false positives). Although DBT is now being introduced in clinical practice the features of this technique have not yet been fully and accurately assessed. Consequently, optimization studies in terms of choosing the most suitable parameters which maximize image quality according to the known limits of breast dosimetry are currently performing. In DBT, scatter radiation can lead to a loss of contrast and to an increase of image noise by reducing the signal-to-difference-noise ratio (SDNR) of a lesion. Moreover the use of an anti-scatter grid is a concern due to the low exposure of the photon flux available per projection. For this reason the main aim of this study was to analyze the influence of the scatter radiation on image quality and the dose delivered to the breast. In particular a detailed analysis of the scatter radiation on the optimal energy that maximizes the SDNR was performed for different monochromatic energies and voltages. To reach this objective the PenEasy Monte Carlo (MC) simulation tool imbedded in the general-purpose main program PENELOPE, was used. After a successful validation of the MC model with measurements, 2D projection images of primary, coherent and incoherent photons were obtained. For that, a homogeneous breast phantom (2, 4, 6, 8 cm) with 25%, 50% and 75% glandular compositions was used, including a 5 mm thick tumor. The images were generated for each monochromatic X-ray energies in the range from 16 keV to 32 keV. For each angular projection considered (25 angular projections covering an arc of 50°) the scatter-to-primary ratio (SPR), the mean glandular dose (MGD) and the signal

  6. Study of a new approach to diagnose breast cancer based on synchrotron radiation scattering properties

    International Nuclear Information System (INIS)

    Conceicao, A.L.C.; Poletti, M.E.

    2012-01-01

    Full text: Breast cancer is the most frequently occurring cancer in women accounting for about 20% of all cancer deaths. This scenario is, among other factors, due to inherent limitations of the current clinical methods of diagnosis based on x-ray absorption. Meanwhile, recent researches have shown that the scattered radiation can provide information about the structures that compose a biological tissue, like breast tissue. Then, the information provided by x-ray scattering techniques can be used to identify breast cancer. In this work, we developed a classification model based on discriminant analysis of scattering profiles of 106 human breast samples histopathologically classified as normal tissue, benign and malignant lesion, at wide (WAXS) and small angle x-ray scattering (SAXS) regions. WAXS and SAXS experiments were carried out at the D12A-XRD1 and D02-SAXS2 beam lines in the National Synchrotron Light Laboratory (LNLS) in Campinas. For WAXS experiment, was used an x-ray beam energy of 11keV allowing to record the momentum transfer interval of 0.7nm -1 ≤(q=4π.sin(θ/2)/λ)≤70.5nm -1 on the NaI(Tl) detector. While for SAXS experiment was used an x-ray wavelength of 1.488 Angstrom, a two-dimensional detector and several sample-detector distances, allowing to get the range of 0.07nm -1 ≤q≤4.20nm -1 . The scattering profiles at both regions, for each sample were used to build the diagnosis model based on discriminant analysis. From WAXS data, differences related to position and intensity of the peaks of the molecular structures were found, when compared normal and pathological breast tissues. While for SAXS these differences were observed in supramolecular structures. The diagnostic model combining the information at WAXS and SAXS yield two linear functions which, allow to correlate changes at molecular scale with those at supramolecular level as well as, to classify correctly all samples analyzed in this study[1]. Finally, the results achieved in this

  7. Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kai, E-mail: kyang11@mgh.harvard.edu; Li, Xinhua; Liu, Bob [Division of Diagnostic Imaging Physics, Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts 02114 (United States)

    2016-03-15

    Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the

  8. Study of electron densities of normal and neoplastic human breast tissues by Compton scattering using synchrotron radiation

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2012-01-01

    Electron densities of 33 samples of normal (adipose and fibroglangular) and neoplastic (benign and malignant) human breast tissues were determined through Compton scattering data using a monochromatic synchrotron radiation source and an energy dispersive detector. The area of Compton peaks was used to determine the electron densities of the samples. Adipose tissue exhibits the lowest values of electron density whereas malignant tissue the highest. The relationship with their histology was discussed. Comparison with previous results showed differences smaller than 4%. - Highlights: ► Electron density of normal and neoplastic breast tissues was measured using Compton scattering. ► Monochromatic synchrotron radiation was used to obtain the Compton scattering data. ► The area of Compton peaks was used to determine the electron densities of samples. ► Adipose tissue shows the lowest electron density values whereas the malignant tissue the highest. ► Comparison with previous results showed differences smaller than 4%.

  9. Study of electron densities of normal and neoplastic human breast tissues by Compton scattering using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Antoniassi, M.; Conceicao, A.L.C. [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo (Brazil); Poletti, M.E., E-mail: poletti@ffclrp.usp.br [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo (Brazil)

    2012-07-15

    Electron densities of 33 samples of normal (adipose and fibroglangular) and neoplastic (benign and malignant) human breast tissues were determined through Compton scattering data using a monochromatic synchrotron radiation source and an energy dispersive detector. The area of Compton peaks was used to determine the electron densities of the samples. Adipose tissue exhibits the lowest values of electron density whereas malignant tissue the highest. The relationship with their histology was discussed. Comparison with previous results showed differences smaller than 4%. - Highlights: Black-Right-Pointing-Pointer Electron density of normal and neoplastic breast tissues was measured using Compton scattering. Black-Right-Pointing-Pointer Monochromatic synchrotron radiation was used to obtain the Compton scattering data. Black-Right-Pointing-Pointer The area of Compton peaks was used to determine the electron densities of samples. Black-Right-Pointing-Pointer Adipose tissue shows the lowest electron density values whereas the malignant tissue the highest. Black-Right-Pointing-Pointer Comparison with previous results showed differences smaller than 4%.

  10. Determination of effective atomic number of breast tissues using scattered radiation; Determinacao do numero atomico efetivo de tecidos mamarios usando a radiacao espalhada

    Energy Technology Data Exchange (ETDEWEB)

    Antoniassi, M.; Conceicao, A.L.C.; Poletti, M.E. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Fac. de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2010-07-01

    The scattered radiation has been used in several industrial and clinical applications since it permits to characterize the scattering material. Several types of information can be extracted from the spectrum of scattered radiation which can be used to characterization of biological tissues such as breast tissues. In this work we have measured Compton and Rayleigh scattering radiation from normal (adipose), benign (fibroadenoma) and malignant (carcinoma) neoplastic breast tissues using a monoenergetic beam of 17.44 keV and a scattering angle of 90 deg C (x = 0.99 angstrom-1). A practical method using the area of elastic and inelastic scattering was used for determining the effective atomic number (Z{sub eff}) of the samples, being validated comparing the experimental obtained values of Z{sub eff} of several standard materials with calculated values using traditional method based on total cross-section of compounds. The obtained results show that exist differences in the distributions of Z{sub eff} of breast tissues, which are related to the content of carbon (Z=6) and oxygen (Z=8) in each tissue type. The results suggest that is possible to use this parameter for characterizing breast tissues, pointing the possibility of its use as a complementary tool for the diagnosis of the breast cancer. (author)

  11. WE-DE-207B-09: Scatter Radiation Measurement From a Digital Breast Tomosynthesis System and Its Impact On Shielding Consideration

    Energy Technology Data Exchange (ETDEWEB)

    Yang, K; Li, X; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To accurately measure the scatter radiation from a Hologic digital breast tomosynthesis (DBT) system and to provide updated scatter distribution to guide radiation shielding calculation for DBT rooms. Methods: A high sensitivity GOS-based linear detector was used to measure the angular distribution of scatter radiation from a Hologic Selenia Dimensions DBT system. The linear detector was calibrated for its energy response of typical DBT spectra. Following the NCRP147 approach, the measured scatter intensity was normalized by the primary beam area and primary air kerma at 1m from the scatter phantom center and presented as the scatter fraction. Direct comparison was made against Simpkin’s initial measurement. Key parameters including the phantom size, primary beam area, and kV/anode/target combination were also studied. Results: The measured scatter-to-primary-ratio and scatter fraction data closely matched with previous data from Simpkin. The measured data demonstrated the unique nonisotropic distribution of the scattered radiation around a Hologic DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous local survey, the scatter air kerma at 1m from the phantom center for wall/door is 0.018mGy/patient, for floor is 0.164mGy/patient, and for ceiling is 0.037mGy/patient. Conclusion: Comparing to Simpkin’s previous data, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload, added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP147 is still sufficient for the Hologic DBT system given the workload from a previous local survey. With the data provided from this study, accurate shielding calculation can be performed for

  12. Radiation scattering techniques

    International Nuclear Information System (INIS)

    Edmonds, E.A.

    1986-01-01

    Radiation backscattering techniques are useful when access to an item to be inspected is restricted to one side. These techniques are very sensitive to geometrical effects. Scattering processes and their application to the determination of voids, thickness measuring, well-logging and the use of x-ray fluorescence techniques are discussed. (U.K.)

  13. Gravitational scattering of electromagnetic radiation

    Science.gov (United States)

    Brooker, J. T.; Janis, A. I.

    1980-01-01

    The scattering of electromagnetic radiation by linearized gravitational fields is studied to second order in a perturbation expansion. The incoming electromagnetic radiation can be of arbitrary multipole structure, and the gravitational fields are also taken to be advanced fields of arbitrary multipole structure. All electromagnetic multipole radiation is found to be scattered by gravitational monopole and time-varying dipole fields. No case has been found, however, in which any electromagnetic multipole radiation is scattered by gravitational fields of quadrupole or higher-order multipole structure. This lack of scattering is established for infinite classes of special cases, and is conjectured to hold in general. The results of the scattering analysis are applied to the case of electromagnetic radiation scattered by a moving mass. It is shown how the mass and velocity may be determined by a knowledge of the incident and scattered radiation.

  14. Light scattering reviews 8 radiative transfer and light scattering

    CERN Document Server

    Kokhanovsky, Alexander A

    2013-01-01

    Light scattering review (vol 8) is aimed at the presentation of recent advances in radiative transfer and light scattering optics. The topics to be covered include: scattering of light by irregularly shaped particles suspended in atmosphere (dust, ice crystals), light scattering by particles much larger as compared the wavelength of incident radiation, atmospheric radiative forcing, astrophysical radiative transfer, radiative transfer and optical imaging in biological media, radiative transfer of polarized light, numerical aspects of radiative transfer.

  15. Dosimetry studies during breast cancer radiation treatment

    International Nuclear Information System (INIS)

    Ahmed, M. O. M.

    2005-06-01

    Previous studies indicated that breast cancer is wildly spread especially in women as compared to men. It is increased after an age of thirty five years in women so it is important to study the effect of exposure to the radiation on the intact breast during the treatment of the breast suffering from cancer. In this work the scattered doses for the intact breast during the treatment of the breast suffering from cancer were measured and also the probability of inducing cancer in it is also discussed. The study was performed for a group of patients composed of twenty five females. Also the backscattered doses to the intact breast were measured for thirteen female patients. During the treatment using gamma rays from Co-60 source the two tangential fields (lateral and medial) were selected for the measurements. The results of exposure to gamma radiation for the lateral and medial fields showed that the mean scattered and backscattered doses to the intact breast were (241.26 cGY,47.49 cGY) and (371.6 cGY,385.4 cGY), respectively. Beside that the somatic risk of induced cancer to the intact breast was found to be (6 .1X10 -3 ,1.2X10 -3 ) and (9.29X10 -3 , 9.63X10 -3 ), respectively. From the results obtained it was concluded that the intact breast received small amounts of radiation doses which may lead to breast cancer for the healthy breast. The recommendations from the present study are to take care of radiation protection to the patient, and also to take care of the patient treatment conditions like temperature, pressure and humidity during the radiation exposure.(Author)

  16. Transition radiation and transition scattering

    International Nuclear Information System (INIS)

    Ginzburg, V.L.

    1982-01-01

    Transition radiation is a process of a rather general character. It occurs when some source, which does not have a proper frequency (for example, a charge) moves at a constant velocity in an inhomogeneous and (or) nonstationary medium or near such a medium. The simplest type of transition radiation takes place when a charge crosses a boundary between two media (the role of one of the media may be played by vacuum). In the case of periodic variation of the medium, transition radiation possesses some specific features (resonance transition radiation or transition scattering). Transition scattering occurs, in particular, when a permittivity wave falls onto an nonmoving (fixed) charge. Transition scattering is closely connected with transition bremsstrahlung radiation. All these transition processes are essential for plasma physics. Transition radiation and transition scattering have analogues outside the framework of electrodynamics (like in the case of Vavilov-Cherenkov radiation). In the present report the corresponding range of phenomena is elucidated, as far as possible, in a generally physical aspect. (Auth.)

  17. Thomson scattering if FIR radiation

    International Nuclear Information System (INIS)

    Evans, D.E.

    1976-12-01

    The frequency spectrum of radiation scattered by collective density fluctuations of electrons in a hot plasma is influenced by ion and electron temperatures, impurity concentration and plasma effective charge, magnetic field, and the level of microturbulence. A pulsed laser suitable for measuring collective scattering in a tokamak will have infrared wavelength, power of the order of MWs and bandwidth of a few 10s of MHz. The extent to which these conditions can be met by optically pumped submillimetre lasers, including narrow band oscillators, amplifiers and superradiance - injection assemblies operated in CH 3 F and D 2 O, under development at the Culham Laboratory, is discussed. (author)

  18. Coherence effects in radiative scattering

    International Nuclear Information System (INIS)

    Knoll, J.; Lenk, R.

    1993-03-01

    The bremsstrahl-production of photons in dense matter is reinvestigated using the example of an exactly solvable quantum mechanical model in one space dimension. Coherence phenomena between successive radiative scatterings among the constituents lead to a modification of the production cross section in the medium relative to the incoherent quasi-free prescription used in kinetic models. Analytic expressions for the correction factor have been derived comparing the quantum rates with the corresponding incoherent quasi-free rates. The result has implications for the kinetic description of all kinds of radiative processes in nucleus-nucleus collisions, both on the level of hadron and parton dynamics. (orig.)

  19. Radiation scatter apparatus and method

    International Nuclear Information System (INIS)

    Molbert, J. L.; Riddle, E. R.

    1985-01-01

    A radiation scatter gauge includes multiple detector locations for developing separate and independent sets of data from which multiple physical characteristics of a thin material and underlying substrate may be determined. In an illustrated embodiment, the apparatus and method of the invention are directed to determining characteristics of resurfaced pavement by nondestructive testing. More particularly, the density and thickness of a thin asphalt overlay and the density of the underlying pavement may be determined

  20. On ionising radiation and breast cancer risk

    Energy Technology Data Exchange (ETDEWEB)

    Mattson, Anders

    1999-05-01

    A cohort of 3,090 women with clinical diagnosis of benign breast disease (BBD) was studied. Of these, 1,216 were treated with radiation therapy during 1925-54 (median age 40 years). The mean dose to the breasts was 5.8 Gy (range 0-50 Gy). Among other organs the lung received the highest scattered dose (0.75 Gy; range 0.004-8.98 Gy) and the rectum the lowest (0.008 Gy; range 0-0.06 Gy). A pooled analysis of eight breast cancer incidence cohorts was done, including: tumour registry data on breast cancer incidence among women in the Life Span Study cohort of atomic bomb survivors; women in Massachusetts who received repeated chest fluoroscopic during lung collapse treatment for tuberculosis; women who received x-ray therapy for acute post-partum mastitis; women who were irradiated in infancy for enlarged thymus glands ; two Swedish cohorts of women who received radiation treatments during infancy for skin hemangioma; and the BBD cohort. Together the cohorts included almost 78,000 women (-35,000 were exposed), around 1.8 million woman-years and 1500 cases. The breast cancer incidence rate as a function of breast dose was analysed using linear-quadratic Poisson regression models. Cell-killing effects and other modifying effects were incorporated through additional log-linear terms. Additive (EAR) and multiplicative (ERR) models were compared in estimating the age-at-exposure patterns and time related excess. The carcinogenic risks associated with radiation in mammographic mass screening is evaluated. Assessment was made in terms of breast cancer mortality and years of life. Effects were related to rates not influenced by a mammographic mass screening program and based on a hypothetical cohort of 100,000 40-year old women with no history of breast cancer being followed to 100 years of age. Two radiation risk assumptions were compared. The dose-response relationship is linear with little support in data for an upward curvature at low to medium doses. The competing effect

  1. On ionising radiation and breast cancer risk

    International Nuclear Information System (INIS)

    Mattson, Anders

    1999-01-01

    A cohort of 3,090 women with clinical diagnosis of benign breast disease (BBD) was studied. Of these, 1,216 were treated with radiation therapy during 1925-54 (median age 40 years). The mean dose to the breasts was 5.8 Gy (range 0-50 Gy). Among other organs the lung received the highest scattered dose (0.75 Gy; range 0.004-8.98 Gy) and the rectum the lowest (0.008 Gy; range 0-0.06 Gy). A pooled analysis of eight breast cancer incidence cohorts was done, including: tumour registry data on breast cancer incidence among women in the Life Span Study cohort of atomic bomb survivors; women in Massachusetts who received repeated chest fluoroscopic during lung collapse treatment for tuberculosis; women who received x-ray therapy for acute post-partum mastitis; women who were irradiated in infancy for enlarged thymus glands ; two Swedish cohorts of women who received radiation treatments during infancy for skin hemangioma; and the BBD) cohort. Together the cohorts included almost 78,000 women (-35,000 were exposed), around 1.8 million woman-years and 1500 cases. The breast cancer incidence rate as a function of breast dose was analysed using linear-quadratic Poisson regression models. Cell-killing effects and other modifying effects were incorporated through additional log-linear terms. Additive (EAR) and multiplicative (ERR) models were compared in estimating the age-at-exposure patterns and time related excess. The carcinogenic risks associated with radiation in mammographic mass screening is evaluated. Assessment was made in terms of breast cancer mortality and years of life. Effects were related to rates not influenced by a mammographic mass screening program and based on a hypothetical cohort of 100,000 40-year old women with no history of breast cancer being followed to 100 years of age. Two radiation risk assumptions were compared. The dose-response relationship is linear with little support in data for an upward curvature at low to medium doses. The competing effect

  2. Light scattering reviews 9 light scattering and radiative transfer

    CERN Document Server

    Kokhanovsky, Alexander A

    2014-01-01

    This book details modern methods of the radiative transfer theory. It presents recent advances in light scattering (measurements and theory) and highlights the newest developments in remote sensing of aerosol and cloud properties.

  3. Scattering of light and other electromagnetic radiation

    CERN Document Server

    Kerker, Milton

    1969-01-01

    The Scattering of Light and Other Electromagnetic Radiation discusses the theory of electromagnetic scattering and describes some practical applications. The book reviews electromagnetic waves, optics, the interrelationships of main physical quantities and the physical concepts of optics, including Maxwell's equations, polarization, geometrical optics, interference, and diffraction. The text explains the Rayleigh2 theory of scattering by small dielectric spheres, the Bessel functions, and the Legendre functions. The author also explains how the scattering functions for a homogenous sphere chan

  4. Breast radiation - discharge

    Science.gov (United States)

    ... underwire. Ask your provider about wearing your breast prosthesis, if you have one. Self-care You need ... swelling ( edema ) in your arm. You have a feeling of tightness in your arm. Rings on your ...

  5. Study of effective atomic number of breast tissues determined using the elastic to inelastic scattering ratio

    Energy Technology Data Exchange (ETDEWEB)

    Antoniassi, M.; Conceicao, A.L.C. [Departamento de Fisica e Matematica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo (Brazil); Poletti, M.E., E-mail: poletti@ffclrp.usp.br [Departamento de Fisica e Matematica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo (Brazil)

    2011-10-01

    In this work we have measured Compton and Rayleigh scattering radiation from normal (adipose and fibroglandular), benign (fibroadenoma) and malignant (ductal carcinoma) breast tissues using a monoenergetic beam of 17.44 keV and a scattering angle of 90{sup o} (x=0.99 A{sup -1}). A practical method using the area of Rayleigh and Compton scattering was used for determining the effective atomic number (Z{sub eff}) of the samples, being validated through measurements of several reference materials. The results show that there are differences in the distributions of Z{sub eff} of breast tissues, which are mainly related to the elemental composition of carbon (Z=6) and oxygen (Z=8) of each tissue type. The results suggest that is possible to use the method to characterize the breast tissues permitting study histological features of the breast tissues related to their elemental composition.

  6. Study of effective atomic number of breast tissues determined using the elastic to inelastic scattering ratio

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceicao, A.L.C.; Poletti, M.E.

    2011-01-01

    In this work we have measured Compton and Rayleigh scattering radiation from normal (adipose and fibroglandular), benign (fibroadenoma) and malignant (ductal carcinoma) breast tissues using a monoenergetic beam of 17.44 keV and a scattering angle of 90 o (x=0.99 A -1 ). A practical method using the area of Rayleigh and Compton scattering was used for determining the effective atomic number (Z eff ) of the samples, being validated through measurements of several reference materials. The results show that there are differences in the distributions of Z eff of breast tissues, which are mainly related to the elemental composition of carbon (Z=6) and oxygen (Z=8) of each tissue type. The results suggest that is possible to use the method to characterize the breast tissues permitting study histological features of the breast tissues related to their elemental composition.

  7. Study of effective atomic number of breast tissues determined using the elastic to inelastic scattering ratio

    Science.gov (United States)

    Antoniassi, M.; Conceição, A. L. C.; Poletti, M. E.

    2011-10-01

    In this work we have measured Compton and Rayleigh scattering radiation from normal (adipose and fibroglandular), benign (fibroadenoma) and malignant (ductal carcinoma) breast tissues using a monoenergetic beam of 17.44 keV and a scattering angle of 90° ( x=0.99 Å -1). A practical method using the area of Rayleigh and Compton scattering was used for determining the effective atomic number ( Zeff) of the samples, being validated through measurements of several reference materials. The results show that there are differences in the distributions of Zeff of breast tissues, which are mainly related to the elemental composition of carbon ( Z=6) and oxygen ( Z=8) of each tissue type. The results suggest that is possible to use the method to characterize the breast tissues permitting study histological features of the breast tissues related to their elemental composition.

  8. Radiation pneumonitis in breast cancer

    International Nuclear Information System (INIS)

    Ferrino, R.; Carvalho, H.A.; Gomes, H.C.; Kuang, L.F.; Aguilar, P.B.; Lederman, M.V.

    1987-01-01

    Forty-nine observations of patients with breast cancer frm 1980 to 1985 were reviewed. All of them received radiotherapy. In 44.9% radiologic findings of radiation pneumonitis were detected and only 9% presented mild or moderate respiratory symptoms. (M.A.C.) [pt

  9. Scattered Radiation Emission Imaging: Principles and Applications

    Directory of Open Access Journals (Sweden)

    M. K. Nguyen

    2011-01-01

    Full Text Available Imaging processes built on the Compton scattering effect have been under continuing investigation since it was first suggested in the 50s. However, despite many innovative contributions, there are still formidable theoretical and technical challenges to overcome. In this paper, we review the state-of-the-art principles of the so-called scattered radiation emission imaging. Basically, it consists of using the cleverly collected scattered radiation from a radiating object to reconstruct its inner structure. Image formation is based on the mathematical concept of compounded conical projection. It entails a Radon transform defined on circular cone surfaces in order to express the scattered radiation flux density on a detecting pixel. We discuss in particular invertible cases of such conical Radon transforms which form a mathematical basis for image reconstruction methods. Numerical simulations performed in two and three space dimensions speak in favor of the viability of this imaging principle and its potential applications in various fields.

  10. Radiation dose to contra lateral breast during treatment of breast malignancy by radiotherapy

    Directory of Open Access Journals (Sweden)

    Chougule Arun

    2007-01-01

    Full Text Available Aims: External beam radiotherapy is being used regularly to treat the breast malignancy postoperatively. The contribution of collimator leakage and scatter radiation dose to contralateral breast is of concern because of high radio sensitivity of breast tissue for carcinogenesis. This becomes more important when the treated cancer breast patient is younger than 45 years and therefore the contralateral breast must be treated as organ at risk. Quantification of contralateral dose during primary breast irradiation is helpful to estimate the risk of radiation induced secondary breast malignancy. Materials and Methods: In present study contralateral breast dose was measured in 30 cancer breast patients undergoing external beam therapy by Co-60 teletherapy machine. Postoperative radiotherapy was delivered by medial and lateral tangential fields on alternate days in addition to supraclavicle field daily with 200 cGy/F to a total dose of 5000 cGy in 25 fractions. CaSO4: Dy themoluminescence dosimeter discs were employed for these measurements. Three TLD discs were put on the surface of skin of contra lateral breast, one at the level of nipple and two at 3 cms away from nipple on both side along the midline for each field. At the end treatment of each filed, TLD discs were removed and measured for dose after 24h on Thelmador - 6000 TLD reader. Results: The dose at the contra lateral breast nipple was to be 152.5 to 254.75 cGy for total primary breast dose of 5000 cGy in 25 equal fractions which amounted to 3.05-6.05% of total dose to diseased breast. Further it was observed that the maximum contribution of contralateral breast dose was due to medical tangential half blocked field. Conclusion: CaSO4; Dy thermoluminescence dosimetry is quite easy, accurate and convenient method to measure the contra lateral breast dose.

  11. Library based x-ray scatter correction for dedicated cone beam breast CT

    International Nuclear Information System (INIS)

    Shi, Linxi; Zhu, Lei; Vedantham, Srinivasan; Karellas, Andrew

    2016-01-01

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  12. Library based x-ray scatter correction for dedicated cone beam breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Linxi; Zhu, Lei, E-mail: leizhu@gatech.edu [Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Vedantham, Srinivasan; Karellas, Andrew [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2016-08-15

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  13. Scattered radiation in fan beam imaging systems

    International Nuclear Information System (INIS)

    Johns, P.C.; Yaffe, M.

    1982-01-01

    Scatter-to-primary energy fluence ratios (S/P) have been studied for fan x-ray beams as used in CT scanners and slit projection radiography systems. The dependence of S/P on phantom diameter, distance from phantom to image receptor, and kilovoltage is presented. An empirical equation is given that predicts S/P over a wide range of fan beam imaging configurations. For CT body scans on a 4th-generation machine, S/P is approximately 5%. Scattered radiation can produce a significant cupping artefact in CT images which is similar to that due to beam hardening. When multiple slices are used in scanned slit radiography, they can be arranged such that the increase in S/P is negligible. Calculations of scatter-to-primary ratios for first order scattering showed that for fan beams the contribution of coherent scatter is comparable to or greater than that of incoherent first scatter

  14. Stationary radiation of objects with scattering media

    International Nuclear Information System (INIS)

    Vasil'eva, Inna A

    2001-01-01

    The radiation observed inside or outside a stationary radiator with a scattering medium is a sum of components, each being determined by, first, the primary radiation from some part of the radiator and, second, the probability of this radiation reaching the region where it is observed. In this review, general and rather simple relations between these components are discussed. These relations, unlike the components themselves, are independent of the specific optical characteristics of the object as well as of its geometry, inhomogeneity, etc. In deriving the relations, the situations in which geometrical optics is either applicable or inapplicable to radiation in a scattering medium are considered. For the case where geometrical optics does apply, stationary relations are derived from the probabilistic stationarity condition for radiation passing through the medium, i.e., from the fact that all radiation emitted in a stationary regime disappears with probability unity. Equilibrium relations are derived from the stationary relations in the particular case of a thermal radiator in an isothermal cavity. To derive the stationary relations in the geometrical optics approximation, we obtain general solutions of the linear equation of transfer using the Green function approach. If geometrical optics cannot be applied to a scattering and radiating medium, only relations for the components of outgoing thermal radiation are obtained, and the generalized Kirchhoff law, obtained by Levin and Rytov using statistical radio-physics methods, is employed. In this case, stationary relations are also derived from a probabilistic stationarity condition; the equilibrium relations follow from the stationary ones as well as from the equilibrium condition for radiation in the isothermal cavity. The quantities involved in all the relations obtained are a subject of experimental and computational spectroscopic studies. Examples of current and potential applications are given. The relations

  15. Multichannel radiography employing scattered radiation

    International Nuclear Information System (INIS)

    Jacobs, A.M.; McInerney, J.J.; Kenney, E.S.

    1985-01-01

    This invention provides a diagnostic imaging system for constructing an image of on area of an interfacial surface within the body of a subject particularly adapted to obtain data for constructing interfaces between a beating heart and the lung. The system comprises a radiation source with means for generating a shaped beam of penetrating radiation; a radiation detector assembly; sensitive volume positioning means attached to both the radiation source and the detectors, which can be used to change the shape of the beam or the orientation of the detectors; a search control circuit; and image construction means

  16. Measurements of computed tomography radiation scatter

    International Nuclear Information System (INIS)

    Van Every, B.; Petty, R.J.

    1992-01-01

    This paper describes the measurement of scattered radiation from a computed tomography (CT) scanner in a clinical situation and compares the results with those obtained from a CT performance phantom and with data obtained from CT manufacturers. The results are presented as iso-dose contours. There are significant differences between the data obtained and that supplied by manufacturers, both in the shape of the iso-dose contours and in the nominal values. The observed scatter in a clinical situation (for an abdominal scan) varied between 3% and 430% of the manufacturers' stated values, with a marked reduction in scatter noted a the head and feet of the patient. These differences appear to be due to the fact that manufacturers use CT phantoms to obtain scatter data and these phantoms do not provide the same scatter absorption geometry as patients. CT scatter was observed to increase as scan field size and slice thickness increased, whilst there was little change in scatter with changes in gantry tilt and table slew. Using the iso-dose contours, the orientation of the CT scanner can be optimised with regard to the location and shielding requirements of doors and windows. Additionally, the positioning of staff who must remain in the room during scanning can be optimised to minimise their exposure. It is estimated that the data presented allows for realistic radiation protection assessments to be made. 13 refs., 5 tabs., 6 figs

  17. Radiation-induced breast cancer

    International Nuclear Information System (INIS)

    Price, J.L.

    1977-01-01

    Concern is expressed over a recent U.K. newspaper report (The Times, 21 January 1977, 5) on the possible hazards of mammography, as women may over-react to the extent of refusing mammography. The problems of radiation risk estimates, particularly at low dose levels, are very briefly reviewed. Recent improvements in mammography techniques have minimised the radiation hazard. Conflicting reports of the mortality rates following mammography screening programmes are discussed. In England and Wales, breast cancer is the commonest cause of death in women aged 35 to 54, and it would be unfortunate if the possible benefits of screening were denied to this age group before the latest mammographic techniques have been fully evaluated. (U.K.)

  18. Radiation-induced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Price, J L [Hammersmith Hospital, London (UK). Postgraduate Medical School

    1977-03-12

    Concern is expressed over a recent U.K. newspaper report (The Times, 21 January 1977, 5) on the possible hazards of mammography, as women may over-react to the extent of refusing mammography. The problems of radiation risk estimates, particularly at low dose levels, are very briefly reviewed. Recent improvements in mammography techniques have minimised the radiation hazard. Conflicting reports of the mortality rates following mammography screening programmes are discussed. In England and Wales, breast cancer is the commonest cause of death in women aged 35 to 54, and it would be unfortunate if the possible benefits of screening were denied to this age group before the latest mammographic techniques have been fully evaluated.

  19. A preliminary study of breast cancer diagnosis using laboratory based small angle x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Round, A R [Daresbury Laboratories, Warrington, WA4 4AD (United Kingdom); Wilkinson, S J [Daresbury Laboratories, Warrington, WA4 4AD (United Kingdom); Hall, C J [Daresbury Laboratories, Warrington, WA4 4AD (United Kingdom); Rogers, K D [Department of Materials and Medical Sciences, Cranfield University, Swindon, SN6 8LA (United Kingdom); Glatter, O [Department of Chemistry, University of Graz (Austria); Wess, T [School of Optometry and Vision Sciences, Cardiff University, Cardiff CF10 3NB, Wales (United Kingdom); Ellis, I O [Nottingham City Hospital, Nottingham (United Kingdom)

    2005-09-07

    Breast tissue collected from tumour samples and normal tissue from bi-lateral mastectomy procedures were examined using small angle x-ray scattering. Previous work has indicated that breast tissue disease diagnosis could be performed using small angle x-ray scattering (SAXS) from a synchrotron radiation source. The technique would be more useful to health services if it could be made to work using a conventional x-ray source. Consistent and reliable differences in x-ray scatter distributions were observed between samples from normal and tumour tissue samples using the laboratory based 'SAXSess' system. Albeit from a small number of samples, a sensitivity of 100% was obtained. This result encourages us to pursue the implementation of SAXS as a laboratory based diagnosis technique.

  20. A preliminary study of breast cancer diagnosis using laboratory based small angle x-ray scattering

    International Nuclear Information System (INIS)

    Round, A R; Wilkinson, S J; Hall, C J; Rogers, K D; Glatter, O; Wess, T; Ellis, I O

    2005-01-01

    Breast tissue collected from tumour samples and normal tissue from bi-lateral mastectomy procedures were examined using small angle x-ray scattering. Previous work has indicated that breast tissue disease diagnosis could be performed using small angle x-ray scattering (SAXS) from a synchrotron radiation source. The technique would be more useful to health services if it could be made to work using a conventional x-ray source. Consistent and reliable differences in x-ray scatter distributions were observed between samples from normal and tumour tissue samples using the laboratory based 'SAXSess' system. Albeit from a small number of samples, a sensitivity of 100% was obtained. This result encourages us to pursue the implementation of SAXS as a laboratory based diagnosis technique

  1. A preliminary study of breast cancer diagnosis using laboratory based small angle x-ray scattering

    Science.gov (United States)

    Round, A. R.; Wilkinson, S. J.; Hall, C. J.; Rogers, K. D.; Glatter, O.; Wess, T.; Ellis, I. O.

    2005-09-01

    Breast tissue collected from tumour samples and normal tissue from bi-lateral mastectomy procedures were examined using small angle x-ray scattering. Previous work has indicated that breast tissue disease diagnosis could be performed using small angle x-ray scattering (SAXS) from a synchrotron radiation source. The technique would be more useful to health services if it could be made to work using a conventional x-ray source. Consistent and reliable differences in x-ray scatter distributions were observed between samples from normal and tumour tissue samples using the laboratory based 'SAXSess' system. Albeit from a small number of samples, a sensitivity of 100% was obtained. This result encourages us to pursue the implementation of SAXS as a laboratory based diagnosis technique.

  2. Effects of Scattering of Radiation on Wormholes

    Directory of Open Access Journals (Sweden)

    Alexander Kirillov

    2018-02-01

    Full Text Available Significant progress in the development of observational techniques gives us the hope to directly observe cosmological wormholes. We have collected basic effects produced by the scattering of radiation on wormholes, which can be used in observations. These are the additional topological damping of cosmic rays, the generation of a diffuse background around any discrete source, the generation of an interference picture, and distortion of the cosmic microwave background (CMB spectrum. It turns out that wormholes in the leading order mimic perfectly analogous effects of the scattering of radiation on the standard matter (dust, hot electron gas, etc.. However, in higher orders, a small difference appears, which allows for disentangling effects of wormholes and ordinary matter.

  3. Scatter radiation exposure during knee arthrography

    International Nuclear Information System (INIS)

    Light, M.C.; Molloi, S.Y.; Yandow, D.R.; Ranallo, F.N.

    1987-01-01

    Knee arthrography, as performed at the authors' institution, was simulated and scattered radiation exposure to a radiologist's gonads, thyroid, and eye lens was measured with a sensitive ionization chamber. Results show that radiologists who regularly conduct knee arthrography examinations can incur doses to the gonads that are less than 6% of the U.S. limits, and to the thyroid and eye that are approximately 10% of the U.S. limits. Since the scatter radiation from overhead imaging of stress views constituted most (greater than or equal to 60%) of the dose to the lens of the eye and the thyroid, spot imaging was evaluated as a substitute for overhead imaging in the assessment of the anterior cruciate ligament. This substitution resulted in no loss of clinical information and has now completely replaced overhead imaging of stress views at this institution

  4. Radiative corrections to deep inelastic muon scattering

    International Nuclear Information System (INIS)

    Akhundov, A.A.; Bardin, D.Yu.; Lohman, W.

    1986-01-01

    A summary is given of the most recent results for the calculaion of radiative corrections to deep inelastic muon-nucleon scattering. Contributions from leptonic electromagnetic processes up to the order a 4 , vacuum polarization by leptons and hadrons, hadronic electromagnetic processes approximately a 3 and γZ interference have been taken into account. The dependence of the individual contributions on kinematical variables is studied. Contributions, not considered in earlier calculations of radiative corrections, reach in certain kinematical regions several per cent at energies above 100 GeV

  5. Scatter Dose in Patients in Radiation Therapy

    International Nuclear Information System (INIS)

    Schmidt, W. F. O.

    2003-01-01

    Patients undergoing radiation therapy are often treated with high energy radiation (bremsstrahlung) which causes scatter doses in the patients from various sources as photon scatter coming from collimator, gantry, patient, patient table or room (walls, floor, air) or particle doses resulting from gamma-particle reactions in the atomic nucleus if the photon energies are above 8 MeV. In the last years new treatment techniques like IMRT (esp the step-and-shoot- or the MIMIC-techniques) have increased interest in these topics again. In the lecture an overview about recent measurements on scatter doses resulting from gantry, table and room shall be given. Scatter doses resulting from the volume treated in the patient to other critical parts of the body like eyes, ovarii etc. have been measured in two diploma works in our institute and are compared with a program (PERIDOSE; van der Giessen, Netherlands) to estimate them. In some cases these scatter doses have led to changes of treatment modalities. Also an overview and estimation of doses resulting from photon-particle interactions is given according to a publication from Gudowska et al.(Gudowska I, Brahme A, Andreo P, Gudowski W, Kierkegaard J. Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beam of end point 50 MeV. Phys Med Biol 1999; 44(9):2099-2125.). Energy dose has been calculated with Monte Carlo-methods and is compared with analytical methods for 50 MV bremsstrahlung. From these data biologically effective doses from particles in different depths of the body can be estimated also for energies used in normal radiotherapy. (author)

  6. Evaluating the scattered radiation intensity in CBCT

    Science.gov (United States)

    Gonçalves, O. D.; Boldt, S.; Nadaes, M.; Devito, K. L.

    2018-03-01

    In this work we calculate the ratio between scattered and transmitted photons (STRR) by a water cylinder reaching a detector matrix element (DME) in a flat array of detectors, similar to the used in cone beam tomography (CBCT), as a function of the field of view (FOV) and the irradiated volume of the scanned object. We perform the calculation by obtaining an equation to determine the scattered and transmitted radiation and building a computer code in order to calculate the contribution of all voxels of the sample. We compare calculated results with the shades of gray in a central slice of a tomography obtained from a cylindrical glass container filled with distilled water. The tomography was performed with an I-CAT tomograph (Imaging Science International), from the Department of Dental Clinic - Oral Radiology, Universidade Federal de Juiz de Fora. The shade of gray (voxel gray value - VGV) was obtained using the software provided with the I-CAT. The experimental results show a general behavior compatible with theoretical previsions attesting the validity of the method used to calculate the scattering contributions from simple scattering theories in cone beam tomography. The results also attest to the impossibility of obtaining Hounsfield values from a CBCT.

  7. Induced Compton scattering effects in radiation transport approximations

    International Nuclear Information System (INIS)

    Gibson, D.R. Jr.

    1982-01-01

    In this thesis the method of characteristics is used to solve radiation transport problems with induced Compton scattering effects included. The methods used to date have only addressed problems in which either induced Compton scattering is ignored, or problems in which linear scattering is ignored. Also, problems which include both induced Compton scattering and spatial effects have not been considered previously. The introduction of induced scattering into the radiation transport equation results in a quadratic nonlinearity. Methods are developed to solve problems in which both linear and nonlinear Compton scattering are important. Solutions to scattering problems are found for a variety of initial photon energy distributions

  8. Induced Compton-scattering effects in radiation-transport approximations

    International Nuclear Information System (INIS)

    Gibson, D.R. Jr.

    1982-02-01

    The method of characteristics is used to solve radiation transport problems with induced Compton scattering effects included. The methods used to date have only addressed problems in which either induced Compton scattering is ignored, or problems in which linear scattering is ignored. Also, problems which include both induced Compton scattering and spatial effects have not been considered previously. The introduction of induced scattering into the radiation transport equation results in a quadratic nonlinearity. Methods are developed to solve problems in which both linear and nonlinear Compton scattering are important. Solutions to scattering problems are found for a variety of initial photon energy distributions

  9. Hypofractionated Whole-Breast Radiation Therapy: Does Breast Size Matter?

    Energy Technology Data Exchange (ETDEWEB)

    Hannan, Raquibul, E-mail: Raquibul.Hannan@gmail.com [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Thompson, Reid F.; Chen Yu; Bernstein, Karen; Kabarriti, Rafi; Skinner, William [Department of Radiation Oncology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York (United States); Chen, Chin C. [Department of Radiation Oncology, Columbia University Medical Center, New York, New York (United States); Landau, Evan; Miller, Ekeni; Spierer, Marnee; Hong, Linda; Kalnicki, Shalom [Department of Radiation Oncology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York (United States)

    2012-11-15

    Purpose: To evaluate the effects of breast size on dose-volume histogram parameters and clinical toxicity in whole-breast hypofractionated radiation therapy using intensity modulated radiation therapy (IMRT). Materials and Methods: In this retrospective study, all patients undergoing breast-conserving therapy between 2005 and 2009 were screened, and qualifying consecutive patients were included in 1 of 2 cohorts: large-breasted patients (chest wall separation >25 cm or planning target volume [PTV] >1500 cm{sub 3}) (n=97) and small-breasted patients (chest wall separation <25 cm and PTV <1500 cm{sub 3}) (n=32). All patients were treated prone or supine with hypofractionated IMRT to the whole breast (42.4 Gy in 16 fractions) followed by a boost dose (9.6 Gy in 4 fractions). Dosimetric and clinical toxicity data were collected and analyzed using the R statistical package (version 2.12). Results: The mean PTV V95 (percentage of volume receiving >= 95% of prescribed dose) was 90.18% and the mean V105 percentage of volume receiving >= 105% of prescribed dose was 3.55% with no dose greater than 107%. PTV dose was independent of breast size, whereas heart dose and maximum point dose to skin correlated with increasing breast size. Lung dose was markedly decreased in prone compared with supine treatments. Radiation Therapy Oncology Group grade 0, 1, and 2 skin toxicities were noted acutely in 6%, 69%, and 25% of patients, respectively, and at later follow-up (>3 months) in 43%, 57%, and 0% of patients, respectively. Large breast size contributed to increased acute grade 2 toxicity (28% vs 12%, P=.008). Conclusions: Adequate PTV coverage with acceptable hot spots and excellent sparing of organs at risk was achieved by use of IMRT regardless of treatment position and breast size. Although increasing breast size leads to increased heart dose and maximum skin dose, heart dose remained within our institutional constraints and the incidence of overall skin toxicity was comparable

  10. Hypofractionated Whole-Breast Radiation Therapy: Does Breast Size Matter?

    International Nuclear Information System (INIS)

    Hannan, Raquibul; Thompson, Reid F.; Chen Yu; Bernstein, Karen; Kabarriti, Rafi; Skinner, William; Chen, Chin C.; Landau, Evan; Miller, Ekeni; Spierer, Marnee; Hong, Linda; Kalnicki, Shalom

    2012-01-01

    Purpose: To evaluate the effects of breast size on dose-volume histogram parameters and clinical toxicity in whole-breast hypofractionated radiation therapy using intensity modulated radiation therapy (IMRT). Materials and Methods: In this retrospective study, all patients undergoing breast-conserving therapy between 2005 and 2009 were screened, and qualifying consecutive patients were included in 1 of 2 cohorts: large-breasted patients (chest wall separation >25 cm or planning target volume [PTV] >1500 cm 3 ) (n=97) and small-breasted patients (chest wall separation 3 ) (n=32). All patients were treated prone or supine with hypofractionated IMRT to the whole breast (42.4 Gy in 16 fractions) followed by a boost dose (9.6 Gy in 4 fractions). Dosimetric and clinical toxicity data were collected and analyzed using the R statistical package (version 2.12). Results: The mean PTV V95 (percentage of volume receiving >= 95% of prescribed dose) was 90.18% and the mean V105 percentage of volume receiving >= 105% of prescribed dose was 3.55% with no dose greater than 107%. PTV dose was independent of breast size, whereas heart dose and maximum point dose to skin correlated with increasing breast size. Lung dose was markedly decreased in prone compared with supine treatments. Radiation Therapy Oncology Group grade 0, 1, and 2 skin toxicities were noted acutely in 6%, 69%, and 25% of patients, respectively, and at later follow-up (>3 months) in 43%, 57%, and 0% of patients, respectively. Large breast size contributed to increased acute grade 2 toxicity (28% vs 12%, P=.008). Conclusions: Adequate PTV coverage with acceptable hot spots and excellent sparing of organs at risk was achieved by use of IMRT regardless of treatment position and breast size. Although increasing breast size leads to increased heart dose and maximum skin dose, heart dose remained within our institutional constraints and the incidence of overall skin toxicity was comparable to that reported in the

  11. Radiation as a cause of breast cancer

    International Nuclear Information System (INIS)

    Simon, N.; Silverstone, S.M.

    1976-01-01

    The possible role of radiation as a factor in the causation of breast cancer was investigated. Some variables said to be associated with a high risk of breast cancer include genetic factors, pre-existing breast disease, artificial menopause, family history of breast cancer, failure to breast feed, older than usual age at time of first pregnancy, high socioeconomic status, specific blood groups, fatty diet, obesity, and hormonal imbalances. To this list we must add ionizing radiation as an additional and serious risk factor in the causation of breast cancer. Among the irradiated groups which have an increase in the incidence of cancer of the breast are: tuberculous women subjected to repeated fluoroscopy; women who received localized x-ray treatments for acute post-partum mastitis; atom-bomb survivors; other x-ray exposures involving the breast, including irradiation in children and in experimental animals; and women who were treated with x rays for acne or hirsuitism. The dose of radiation received by the survivors of the atom bomb who subsequently developed cancer of the breast ranged from 80 to 800 rads, the tuberculous women who were fluoroscoped received an estimated 50 to 6,000 rads, the women who were treated for mastitis probably were exposed to 30 to 700 rads, and the patients with acne received 100 to 6,000 rads. These imprecise estimates are compared with mammographic doses in the range of 10s of rads to the breast at each examination, an imprecise estimate depending on technique and equipment. However imprecise these estimates may be, it is apparent that younger women are more likely than older women to develop cancer from exposure to radiation. It is pointed out that the American Cancer Society advises that women under 35 years should have mammography only for medical indication, not for so-called screening

  12. An experimental study of the scatter correction by using a beam-stop-array algorithm with digital breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ye-Seul; Park, Hye-Suk; Kim, Hee-Joung [Yonsei University, Wonju (Korea, Republic of); Choi, Young-Wook; Choi, Jae-Gu [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2014-12-15

    Digital breast tomosynthesis (DBT) is a technique that was developed to overcome the limitations of conventional digital mammography by reconstructing slices through the breast from projections acquired at different angles. In developing and optimizing DBT, The x-ray scatter reduction technique remains a significant challenge due to projection geometry and radiation dose limitations. The most common approach to scatter reduction is a beam-stop-array (BSA) algorithm; however, this method raises concerns regarding the additional exposure involved in acquiring the scatter distribution. The compressed breast is roughly symmetric, and the scatter profiles from projections acquired at axially opposite angles are similar to mirror images. The purpose of this study was to apply the BSA algorithm with only two scans with a beam stop array, which estimates the scatter distribution with minimum additional exposure. The results of the scatter correction with angular interpolation were comparable to those of the scatter correction with all scatter distributions at each angle. The exposure increase was less than 13%. This study demonstrated the influence of the scatter correction obtained by using the BSA algorithm with minimum exposure, which indicates its potential for practical applications.

  13. Coherent scattering of electromagnetic radiation by a polarized particle system

    International Nuclear Information System (INIS)

    Agre, M.Ya.; Rapoport, L.P.

    1996-01-01

    The paper deals with the development of the theory of coherent scattering of electromagnetic waves by a polarized atom or molecular system. Peculiarities of the angular distribution and polarization peculiarities of scattered radiation are discussed

  14. Effect of breast augmentation after breast-conserving surgery for breast cancer on radiation dose. Silicone prosthesis and changes in radiation dose

    International Nuclear Information System (INIS)

    Tonari, Ayako; Nako, Yasunobu; Ikezaki, Hiromi; Maruyama, Yasushi; Ikeda, Ikuo; Kusuda, Junko; Harii, Kiyonori; Takayama, Makoto

    2008-01-01

    The results of a study simulating postoperative radiation therapy of remaining breast tissue with a silicone bag prosthesis implanted to examine the effects of the prosthesis on radiation dosage and surrounding tissue are reported. The evaluation was conducted in two stages: a water phantom was used to evaluate scattering effects of a prosthesis installed inside the phantom using glass rod detector (GRD) set around the prosthesis. Measurements were conducted on both entrance and rear sides of the prosthesis. A Rand phantom was used to measure radiation doses around the prosthesis. The first evaluation resulted in a less than 5.4% reduction in dose at the rear side of the prosthesis whereas the second evaluation, for opposing portal irradiation used with breast-conserving surgical treatment, showed the effects of the prosthesis on radiation dosage being within ±2%, the permitted treatment range. In conclusion, for treating breast cancer, combining surgical treatment of the cancer with implanting of prosthesis for breast reconstruction followed by radiation treatment appears feasible as no effects on dosage were observed on treatment effectiveness. (author)

  15. Scattering of Non-Relativistic Charged Particles by Electromagnetic Radiation

    Science.gov (United States)

    Apostol, M.

    2017-11-01

    The cross-section is computed for non-relativistic charged particles (like electrons and ions) scattered by electromagnetic radiation confined to a finite region (like the focal region of optical laser beams). The cross-section exhibits maxima at scattering angles given by the energy and momentum conservation in multi-photon absorption or emission processes. For convenience, a potential scattering is included and a comparison is made with the well-known Kroll-Watson scattering formula. The scattering process addressed in this paper is distinct from the process dealt with in previous studies, where the scattering is immersed in the radiation field.

  16. Breast tissue classification using x-ray scattering measurements and multivariate data analysis

    Science.gov (United States)

    Ryan, Elaine A.; Farquharson, Michael J.

    2007-11-01

    This study utilized two radiation scatter interactions in order to differentiate malignant from non-malignant breast tissue. These two interactions were Compton scatter, used to measure the electron density of the tissues, and coherent scatter to obtain a measure of structure. Measurements of these parameters were made using a laboratory experimental set-up comprising an x-ray tube and HPGe detector. The breast tissue samples investigated comprise five different tissue classifications: adipose, malignancy, fibroadenoma, normal fibrous tissue and tissue that had undergone fibrocystic change. The coherent scatter spectra were analysed using a peak fitting routine, and a technique involving multivariate analysis was used to combine the peak fitted scatter profile spectra and the electron density values into a tissue classification model. The number of variables used in the model was refined by finding the sensitivity and specificity of each model and concentrating on differentiating between two tissues at a time. The best model that was formulated had a sensitivity of 54% and a specificity of 100%.

  17. Breast tissue classification using x-ray scattering measurements and multivariate data analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, Elaine A; Farquharson, Michael J [School of Allied Health Sciences, City University, Charterhouse Square, London EC1M 6PA (United Kingdom)

    2007-11-21

    This study utilized two radiation scatter interactions in order to differentiate malignant from non-malignant breast tissue. These two interactions were Compton scatter, used to measure the electron density of the tissues, and coherent scatter to obtain a measure of structure. Measurements of these parameters were made using a laboratory experimental set-up comprising an x-ray tube and HPGe detector. The breast tissue samples investigated comprise five different tissue classifications: adipose, malignancy, fibroadenoma, normal fibrous tissue and tissue that had undergone fibrocystic change. The coherent scatter spectra were analysed using a peak fitting routine, and a technique involving multivariate analysis was used to combine the peak fitted scatter profile spectra and the electron density values into a tissue classification model. The number of variables used in the model was refined by finding the sensitivity and specificity of each model and concentrating on differentiating between two tissues at a time. The best model that was formulated had a sensitivity of 54% and a specificity of 100%.

  18. Breast cancer biology for the radiation oncologist

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Jonathan [Northwestern Univ., Chicago, IL (United States). Dept. of Radiation Oncology; Small, William [Loyola Univ. Chicago, Maywood, IL (United States). Stritch School of Medicine, Cardianl Bernardin Cancer Center; Woloschak, Gayle E. (ed.) [Northwestern Univ. Feinberg, Chicago, IL (United States). School of Medicine

    2015-10-01

    This is the first textbook of its kind devoted to describing the biological complexities of breast cancer in a way that is relevant to the radiation oncologist. Radiation Oncology has long treated breast cancer as a single biological entity, with all treatment decisions being based on clinical and pathologic risk factors. We are now beginning to understand that biological subtypes of breast cancer may have different risks of recurrence as well as different intrinsic sensitivity to radiotherapy. Multi-gene arrays that have for years been used to predict the risk of distant recurrence and the value of systemic chemotherapy may also have utility in predicting the risk of local recurrence. Additionally, the targeted agents used to treat breast cancer may interact with radiotherapy in ways that can be beneficial or undesirable. All of these emerging issues are extensively discussed in this book, and practical evidence-based treatment recommendations are presented whenever possible.

  19. Breast cancer biology for the radiation oncologist

    International Nuclear Information System (INIS)

    Strauss, Jonathan; Small, William; Woloschak, Gayle E.

    2015-01-01

    This is the first textbook of its kind devoted to describing the biological complexities of breast cancer in a way that is relevant to the radiation oncologist. Radiation Oncology has long treated breast cancer as a single biological entity, with all treatment decisions being based on clinical and pathologic risk factors. We are now beginning to understand that biological subtypes of breast cancer may have different risks of recurrence as well as different intrinsic sensitivity to radiotherapy. Multi-gene arrays that have for years been used to predict the risk of distant recurrence and the value of systemic chemotherapy may also have utility in predicting the risk of local recurrence. Additionally, the targeted agents used to treat breast cancer may interact with radiotherapy in ways that can be beneficial or undesirable. All of these emerging issues are extensively discussed in this book, and practical evidence-based treatment recommendations are presented whenever possible.

  20. Radiation-induced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Patey, D

    1977-02-12

    Following on the suggestion (Simon, N., and Silverstone, S.M., Bulletin of the New York Academy of Medicine, 52: 741 (1976)) that repeated mammography should be avoided in fit women with a life expectancy greater than 20 years, it is suggested that it should also be avoided in breasts in which the malignant potentiality of the epithelium is known to be relatively high. The best example is the opposite breast following the development of carcinoma in one breast, a situation in which regular follow-up mammography was once regarded as particularly indicated. The same theoretical considerations are an argument against the treatment of carcinoma of the breast by excision of the lump and radiotherapy to the remaining breast tissue.

  1. Radiation-induced breast cancer

    International Nuclear Information System (INIS)

    Finnerty, N.A.; Buzdar, A.U.; Blumenschein, G.R.

    1984-01-01

    Between 1975 and 1983, sixteen patients with a history of irradiation at an early age to the head, neck, or chest areas for a variety of conditions in whom breast cancer subsequently developed were seen at out institute. The median latent period between the irradiation and the development of breast cancer was 420 months. The distribution of patients by stage of the disease and the median age at diagnosis of this subgroup was similar to the breast cancer observed in the general population. The subsequent course of this disease was also similar to the breast cancer observed in the general population. A substantial number of women have been exposed to irradiation at a young age, and these women are at a higher risk of having breast cancer develop. These women should be closely observed to discover the disease in an early curable stage

  2. Acquiring molecular interference functions of X-ray coherent scattering for breast tissues by combination of simulation and experimental methods

    International Nuclear Information System (INIS)

    Chaparian, A.; Oghabian, M. A.; Changizi, V.

    2009-01-01

    Recently, it has been indicated that X-ray coherent scatter from biological tissues can be used to access signature of tissue. Some scientists are interested in studying this effect to get early detection of breast cancer. Since experimental methods for optimization are time consuming and expensive, some scientists suggest using simulation. Monte Carlo codes are the best option for radiation simulation: however, one permanent defect with Monte Carlo codes has been the lack of a sufficient physical model for coherent (Rayleigh) scattering, including molecular interference effects. Materials and Methods: It was decided to obtain molecular interference functions of coherent X-ray scattering for normal breast tissues by combination of modeling and experimental methods. A Monte Carlo simulation program was written to simulate the angular distribution of scattered photons for the normal breast tissue samples. Moreover, experimental diffraction patterns of these tissues were measured by means of energy dispersive X-ray diffraction method. The simulation and experimental data were used to obtain a tabulation of molecular interference functions for breast tissues. Results: With this study a tabulation of molecular interference functions for normal breast tissues Was prepared to facilitate the simulation diffraction patterns of the tissues without any experimental. Conclusion: The method may lead to design new systems for early detection of breast cancer.

  3. Protection of the contralateral breast during radiation therapy for breast cancer

    International Nuclear Information System (INIS)

    Garrigo, E.; Zunino, S.; Germanier, A.

    2008-01-01

    Conformal Radiation Therapy (3DCRT) and Intensity Modulated Radiotherapy (IMRT) improve the relationship between tumor control and complications in normal tissue. However, these techniques may cause an increase of the normal tissue volume irradiated with low doses or an increase of the doses outside the beam. The aim of this work was to measure and compare the scatter dose to the contralateral breast using both the conventional two-field technique and the 3DCRT technique with blocks. The contralateral breast dose was measured with thermoluminescent dosimeters. The present work is divided in three parts: 1)Characterization of the radiation field outside the treatment beam; 2) Determination of the dose to the contralateral breast; 3) Design and construction of a shield to reduce the scatter dose to the contralateral breast. Treatment using 3DCRT technique was delivered to a phantom. From one to ten 2 mm thick lead sheets were placed on the dosimeters to attenuate radiation to the contralateral breast from the head, without blocking the treatment beam. Using the conventional technique the average dose to the contralateral breast was 2.09 Gy,4.18%(2.9%-19%) of the 50 Gy prescribed dose. The contribution of the medial field was 3.36% (2.3%-21.1%) and of the lateral field 0.86%(0.4%-3.7%). When using 3DCRT technique the average dose to the opposite breast was 5,9 Gy,11.8% (7.9%-24%) of the prescribed dose. The contribution of the medial field was 10.3% (6.7%-20%) and of the lateral field 1.6% (1.1%-3.8%). A 2 mm thick lead shield with a 0.2 g/cm2 thick wax coat was constructed which reduced the dose from 11.8% to less than 2%. The blocks increase the dose to the contralateral breast, the highest dose being attributed to the medial field. Our shield reduced the dose, which allowed the regular use of 3DCRT with blocks. In addition, we found that this shield was comfortable for the patients and easy to position for the therapists. (author)

  4. Validation of MCNP4A for repository scattered radiation analysis

    International Nuclear Information System (INIS)

    Haas, M.N.; Su, S.

    1998-02-01

    Comparison is made between experimentally determined albedo (scattered) radiation and MCNP4A predictions in order to provide independent validation for repository shielding analysis. Both neutron and gamma scattered radiation fields from concrete ducts are compared in this paper. Satisfactory agreement is found between actual and calculated results with conservative values calculated by the MCNP4A code for all conditions

  5. Application of the Radiative Transfer Equation (RTE) to Scattering by ...

    African Journals Online (AJOL)

    Application of the Radiative Transfer Equation (RTE) to Scattering by a Dust Aerosol Layer. ... Incident radiation in its journey through the atmosphere before reaching the earth surface encounters particles of different sizes and composition such as dust aerosols resulting in interactions that lead to absorption and scattering.

  6. Bolus effect to reduce skin dose of the caontralateral breast during breast cancer radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Won, Young Jin [Dept. of Radiation Oncology, InJe University Ilsan Paik Hospital, Goyang (Korea, Republic of); Kim, Jong Won; Kim, Jung Hoon [Dept. of Radiology, Radiation Oncology, KonYang University Hospital, Daejeon (Korea, Republic of)

    2017-06-15

    The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge 15 degrees were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

  7. Preoperative breast radiation therapy: Indications and perspectives

    DEFF Research Database (Denmark)

    Lightowlers, S V; Boersma, L J; Fourquet, A

    2017-01-01

    Preoperative breast radiation therapy (RT) is not a new concept, but older studies failed to change practice. More recently, there has been interest in revisiting preoperative RT using modern techniques. This current perspective discusses the indications, summarises the published literature and t...

  8. Breast cancer study in rats by using Raman scattering

    International Nuclear Information System (INIS)

    Martinez E, J. C.; Cordova F, T.; Roca Ch, J. M.; Hernandez R, A.

    2015-10-01

    Full text: The use of Raman scattering to differentiate the biochemistry and hence distinguish between normal and abnormal samples of breast cancer with induced stress was investigated. Twelve different rat serum samples (5 control samples and 7 breast cancer samples) were measured. 25 spectra per sample were acquired in a region of 50 X 50 microns. Three hundred spectra were recorded and the spectral diagnostic models were constructed by using multivariate statistical analysis on the spectral matrix to carry out the discrimination between the control samples and cancers samples with induced stress. The spectral recording was performed with Raman microscopy system Thermo Scientific XRD in the range from 200 to 2000 cm -1 with a laser source of 780 nm, 24 m W of power and 50 s and exposure time were used for each spectrum. It is shown that the serum samples from rats with breast cancer and the control group can be discriminate when the multivariate analysis methods are applied to their Raman data set. The ratios were significant and correspond to proteins and phospholipids. The preliminary results suggest that the Raman spectroscopy could be an alternative technique to study the breast cancer in humans in a near future. (Author)

  9. Breast cancer study in rats by using Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    Martinez E, J. C. [IPN, Unidad Profesional Interdisciplinaria de Ingenieria, Campus Guanajuato, Av. Mineral de Valenciana 200, Col. Fracc. Industrial Puerto Interior, 36275 Silao, Guanajuato (Mexico); Cordova F, T.; Roca Ch, J. M.; Hernandez R, A., E-mail: jcmartineze@ipn.mx [Universidad de Guanajuato, Division de Ciencias e Ingenierias, Departamento de Ingenieria Fisica, Loma del Bosque 103, Col. Lomas del Campestre, 37150 Leon, Guanajuato (Mexico)

    2015-10-15

    Full text: The use of Raman scattering to differentiate the biochemistry and hence distinguish between normal and abnormal samples of breast cancer with induced stress was investigated. Twelve different rat serum samples (5 control samples and 7 breast cancer samples) were measured. 25 spectra per sample were acquired in a region of 50 X 50 microns. Three hundred spectra were recorded and the spectral diagnostic models were constructed by using multivariate statistical analysis on the spectral matrix to carry out the discrimination between the control samples and cancers samples with induced stress. The spectral recording was performed with Raman microscopy system Thermo Scientific XRD in the range from 200 to 2000 cm{sup -1} with a laser source of 780 nm, 24 m W of power and 50 s and exposure time were used for each spectrum. It is shown that the serum samples from rats with breast cancer and the control group can be discriminate when the multivariate analysis methods are applied to their Raman data set. The ratios were significant and correspond to proteins and phospholipids. The preliminary results suggest that the Raman spectroscopy could be an alternative technique to study the breast cancer in humans in a near future. (Author)

  10. Preliminary study of human breast tissue using synchrotron radiation combining WAXS and SAXS techniques

    International Nuclear Information System (INIS)

    Conceicao, A.L.C.; Antoniassi, M.; Poletti, M.E.; Caldas, L.V.E.

    2010-01-01

    Using synchrotron radiation, we combined simultaneously wide angle X-ray scattering (WAXS) and small angle X-ray scattering (SAXS) techniques to obtain the scattering profiles of normal and neoplastic breast tissues samples at the momentum transfer range 6.28 nm -1 ≤Q(=4π.sin(θ/2)/λ)≤50.26 nm -1 and 0.15 nm -1 ≤Q≤1.90 nm -1 , respectively. The results obtained show considerable differences between the scattering profiles of these tissues. We verified that the combination of some parameters (ratio between glandular and adipose peak intensity and third-order axial peak intensity) extracted from scattering profiles can be used for identifying breast cancer.

  11. Breast cancer induced by protracted radiation exposures

    International Nuclear Information System (INIS)

    Elkind, M.M.

    1997-01-01

    The experience at Hiroshima/Nagasaki demonstrated that breast cancer can be induced by single doses of ionizing radiation following latencies of 10-40 years. Several epidemiological studies, usually involving ancillary low-LET radiation to the breast, have demonstrated that breast cancer can be induced by protracted exposures, with similar latencies, and with similar dependencies on dose. Radiobiologically these results suggest that the target cells involved were deficient in repair of low-LET damage even when the protraction was over months to years. Since three-quarters of breast tumors originate in the ducts where their proliferation is controlled by menstrual-cycle timed estrogen/progesterone secretions, these cells periodically were in cycle. Thus, the two main elements of a conceptual model for radon-induced lung cancer -- kinetics and deficient repair -- are satisfied. The model indicates that breast cancer could be the cumulative effect of protracted small exposures, the risk from any one of which ordinarily would be quite small. (author)

  12. Generalized Morphea after Breast Cancer Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Jonathan Kushi

    2011-01-01

    Full Text Available We present a case of a 69-year-old woman who received external beam radiation for the treatment of breast cancer. Seven months later, she developed generalized morphea involving the area of irradiated skin of the breast as well as distant sites of the groin and distal lower extremity. Postirradiation morphea is an uncommon yet well-documented phenomenon, usually confined to the radiated site and the immediate surrounding tissue. To our knowledge, this is only the fourth reported case of morphea occurring distant from the radiation field. While most cases of postirradiation morphea have been shown to either resolve spontaneously or respond to topical corticosteroids, our patient required systemic therapy with methotrexate, which resulted in clinical improvement. With this paper, we hope to bring further awareness to this phenomenon and demonstrate a successful treatment response with the use of methotrexate in postirradiation generalized morphea.

  13. Breast tomography with synchrotron radiation: preliminary results

    International Nuclear Information System (INIS)

    Pani, Silvia; Longo, Renata; Dreossi, Diego; Montanari, Francesco; Olivo, Alessandro; Arfelli, Fulvia; Bergamaschi, Anna; Poropat, Paolo; Rigon, Luigi; Zanconati, Fabrizio; Palma, Ludovico Dalla; Castelli, Edoardo

    2004-01-01

    A system for in vivo breast imaging with monochromatic x-rays has been designed and built at the synchrotron radiation facility Elettra in Trieste (Italy) and will be operational in 2004. The system design involves the possibility of performing both planar mammography and breast tomography. In the present work, the first results obtained with a test set-up for breast tomography are shown and discussed. Tomographic images of in vitro breasts were acquired using monochromatic x-ray beams in the energy range 20-28 keV and a linear array silicon pixel detector. Tomograms were reconstructed using standard filtered backprojection algorithms; the effect of different filters was evaluated. The attenuation coefficients of fibroglandular and adipose tissue were measured, and a quantitative comparison of images acquired at different energies was performed by calculating the differential signal-to-noise ratio of fibroglandular details in adipose tissue. All images required a dose comparable to the dose delivered in clinical, conventional mammography and showed a high resolution of the breast structures without the overlapping effects that limit the visibility of the structures in 2D mammography. A quantitative evaluation of the images proves that the image quality at a given dose increases in the considered energy range and for the considered breast sizes

  14. Castration in breast cancer. Surgery or radiation

    International Nuclear Information System (INIS)

    Hernandez Munoz, G.

    1977-01-01

    A summary is done on the indication of oophorectomy - by surgery or radiation - in the treatment of breast cancer. Prophylactic - and therapeutic oophorectomy are analysed. It is concluded that the treatment of advanced cancer is a fight against time, once the survival of patients ought to be prolonged with the minor number of therapeutic agents, avoiding the usage of them all at once not to exaust them. Castration performed with therapeutic purposes in pre-or post-menopause patients with hyperestrogenism is the first link in the chain of paliative treatment of advanced breast cancer. (M.A.) [pt

  15. Scaling, scattering, and blackbody radiation in classical physics

    International Nuclear Information System (INIS)

    Boyer, Timothy H

    2017-01-01

    Here we discuss blackbody radiation within the context of classical theory. We note that nonrelativistic classical mechanics and relativistic classical electrodynamics have contrasting scaling symmetries which influence the scattering of radiation. Also, nonrelativistic mechanical systems can be accurately combined with relativistic electromagnetic radiation only provided the nonrelativistic mechanical systems are the low-velocity limits of fully relativistic systems. Application of the no-interaction theorem for relativistic systems limits the scattering mechanical systems for thermal radiation to relativistic classical electrodynamic systems, which involve the Coulomb potential. Whereas the naive use of nonrelativistic scatterers or nonrelativistic classical statistical mechanics leads to the Rayleigh–Jeans spectrum, the use of fully relativistic scatterers leads to the Planck spectrum for blackbody radiation within classical physics. (paper)

  16. Radiation efficacy and biological risk from whole-breast irradiation via intensity modulated radiation therapy (IMRT)

    Science.gov (United States)

    Desantis, David M.

    Radiotherapy is an established modality for women with breast cancer. During the delivery of external beam radiation to the breast, leakage, scattered x-rays from the patient and the linear accelerator also expose healthy tissues and organs outside of the breast, thereby increasing the patient's whole-body dose, which then increases the chance of developing a secondary, radiation-induced cancer. Generally, there are three IntensityModulated Radiotherapy (IMRT) delivery techniques from a conventional linear accelerator; forward planned (FMLC), inverse planned 'sliding window' (DMLC), and inverse planned 'step-and-shoot' (SMLC). The goal of this study was to determine which of these three techniques delivers an optimal dose to the breast with the least chance of causing a fatal, secondary, radiation-induced cancer. A conventional, non-IMRT, 'Wedge' plan also was compared. Computerized Tomography (CT) data sets for both a large and small sized patient were used in this study. With Varian's Eclipse AAA algorithm, the organ doses specified in the revised ICRP 60 publication were used to calculate the whole-body dose. Also, an anthropomorphic phantom was irradiated with thermoluminescent dosimeters (TLD) at each organ site for measured doses. The risk coefficient from the Biological Effects of Ionizing Radiation (BEIR) VII report of 4.69 x 10-2 deaths per Gy was used to convert whole-body dose to risk of a fatal, secondary, radiation-induced cancer. The FMLC IMRT delivered superior tumor coverage over the 3D conventional plan and the inverse DMLC or SMLC treatment plans delivered clinically equivalent tumor coverage. However, the FMLC plan had the least likelihood of inadvertently causing a fatal, secondary, radiation-induced cancer compared to the inverse DMLC, SMLC, and Wedge plans.

  17. Magnetic X-Ray Scattering with Synchrotron Radiation

    DEFF Research Database (Denmark)

    Moncton, D. E.; Gibbs, D.; Bohr, Jakob

    1986-01-01

    With the availability of high-brilliance synchrotron radiation from multiple wigglers, magnetic X-ray scattering has become a powerful new probe of magnetic structure and phase transitions. Similar to the well-established magnetic neutron scattering technique, magnetic X-ray scattering methods have...... many complementary advantages. A brief review is presented of the history of magnetic X-ray scattering as well as recent results obtained in studies of the rare-earth magnet holmium with emphasis on instrumentational aspects. In particular, the development of a simple polarization analyzer...... to distinguish charge and magnetic scattering is described....

  18. Some aspects of transition radiation and scattering theory

    International Nuclear Information System (INIS)

    Ginzburg, V.L.; Tsytovich, V.N.

    1978-01-01

    Some aspects of transition radiation and transition scattering theory are considered. The transition radiation in vacuum is analysed in the presence of a strong magnetic field. It is shown, that the constant electro-magnetic field makes vacuum similar to the uniaxial ferrodielectric. The appearance of the transition radiation in the nonstationary medium is discussed when its properties in the medium change abruptly in time. It is obtained, that both types of the transition radiation for nonrelativistic particles (on an abrupt boundary of the two media interface and under an abrupt change in time of the medium properties) differ quantitatively (on the order of the value). The role of the radiation transition and scattering in plasma physics has been elucidated from different points. Four most important features of these processes are pointed out. Particularly, essential is shown to be the type of the transition scattering when one plasma wave, being the dielectric constant wave transforms into another one also a plasma wave. In the processes of the transition scattering an essential part is played by the effects of the space dispersion, particularly when the scattering takes place on the small velocity particles. Finally besides transition scattering there exists in plasma or in some cases prevails a Thomson scattering. In this case an important role in plasma is played by the interference between the Thomson and the transition scattering

  19. Scattered radiation from applicators in clinical electron beams

    International Nuclear Information System (INIS)

    Battum, L J van; Zee, W van der; Huizenga, H

    2003-01-01

    In radiotherapy with high-energy (4-25 MeV) electron beams, scattered radiation from the electron applicator influences the dose distribution in the patient. In most currently available treatment planning systems for radiotherapy this component is not explicitly included and handled only by a slight change of the intensity of the primary beam. The scattered radiation from an applicator changes with the field size and distance from the applicator. The amount of scattered radiation is dependent on the applicator design and on the formation of the electron beam in the treatment head. Electron applicators currently applied in most treatment machines are essentially a set of diaphragms, but still do produce scattered radiation. This paper investigates the present level of scattered dose from electron applicators, and as such provides an extensive set of measured data. The data provided could for instance serve as example input data or benchmark data for advanced treatment planning algorithms which employ a parametrized initial phase space to characterize the clinical electron beam. Central axis depth dose curves of the electron beams have been measured with and without applicators in place, for various applicator sizes and energies, for a Siemens Primus, a Varian 2300 C/D and an Elekta SLi accelerator. Scattered radiation generated by the applicator has been found by subtraction of the central axis depth dose curves, obtained with and without applicator. Scattered radiation from Siemens, Varian and Elekta electron applicators is still significant and cannot be neglected in advanced treatment planning. Scattered radiation at the surface of a water phantom can be as high as 12%. Scattered radiation decreases almost linearly with depth. Scattered radiation from Varian applicators shows clear dependence on beam energy. The Elekta applicators produce less scattered radiation than those of Varian and Siemens, but feature a higher effective angular variance. The scattered

  20. Multiple Aperture Radiation Therapy (MART) for Breast Cancer

    National Research Council Canada - National Science Library

    Li, Tianfang

    2006-01-01

    Conventional breast radiotherapy utilizes two opposed tangential fields (OTF) can result in high radiation dose to lung and heart and inhomogeneous dose distribution in the target for large-size breast...

  1. Analysis of radiation pneumonitis outside the radiation field in breast conserving therapy for early breast cancer

    International Nuclear Information System (INIS)

    Ogo, Etsuyo; Fujimoto, Kiminori; Hayabuchi, Naofumi

    2002-01-01

    In a retrospective study of radiation-induced pulmonary changes for patients with breast conserving therapy for early breast cancer, we sent questionnaires to the main hospitals in Japan. In this study, we analyzed pulmonary changes after tangential whole-breast irradiation. The purpose of this study was to determine the incidence and risk factors for radiation pneumonitis outside the radiation field. The questionnaires included patients data, therapy data, and lung injury information between August 1999 and May 2000. On the first questionnaires, answer letters were received from 107 institutions out of 158 (67.7%). On the second questionnaires, response rate (hospitals which had radiation pneumonitis outside the radiation field) was 21.7% (23/106). We could find no risk factors of this type of pneumonitis. We suggested that lung irradiation might trigger this type of pneumonitis which is clinically similar to BOOP (bronchiolitis obliterans organizing pneumonia). It developed in 1.5-2.1% among the patients with breast conserving surgery and tangential whole-breast irradiation. And it is likely appeared within 6 months after radiotherapy. (author)

  2. Analysis by absorption and scattering of radiation. A current bibliography

    International Nuclear Information System (INIS)

    Bujdoso, E.

    2002-01-01

    A current bibliography with 100 references based on INIS Atomindex has been compiled on Analysis by absorption and scattering of radiation for years 1998-1999. References are arranged by first author's names. (N.T.)

  3. Distance factor on reducing scattered radiation risk during interventional fluoroscopy

    International Nuclear Information System (INIS)

    Husaini Salleh; Mohd Khalid Matori; Muhammad Jamal Mat Isa; Zainal Jamaluddin; Mohd Firdaus Abdul Rahman; Mohd Khairusalih Mohd Zin

    2012-01-01

    Interventional Radiology (IR) is subspecialty of diagnostic radiology where minimally invasive procedures are performed using an x-ray as a guidance. This procedure can deliver high radiation doses to patient and medical staff compared with other radiological method due to long screening time. The use of proper shielding, shorten the exposure time and keep the distance are the practices to reduce scattered radiation risks to staff involve in this procedure. This project is to study the distance factor on reducing the scattered radiation effect to the medical staff. It also may provide the useful information which can be use to establish the scattered radiation profile during the IR for the sake of radiation protection and safety to the medical staff involved. (author)

  4. Roles of scattered radiation in SRIXE

    International Nuclear Information System (INIS)

    Hanson, A.L.

    1988-01-01

    The scattering of x-rays is the major source of background and hence is a limiting factor in the minimum detectable limits available with SRIXE measurements. The scattering can be utilized for normalizing the net peak areas to fluctuations in sample thickness or mass on a relative basis or on a comparative basis. Even then measurement of the scattered x-rays should be made at backward angles. Measurement at forward angles should be avoided because of diffraction problems. The uncertainties in the measurement of an absolute intensity of the x-rays can be extremely large

  5. Clinical significance of radiation therapy in breast recurrence and prognosis in breast-conserving surgery

    International Nuclear Information System (INIS)

    Nishimura, Reiki; Nagao, Kazuharu; Miyayama, Haruhiko

    1999-01-01

    Significant risk factors for recurrence of breast cancer after breast-conserving therapy, which has become a standard treatment for breast cancer, are positive surgical margins and the failure to perform radiation therapy. In this study, we evaluated the clinical significance of radiation therapy after primary surgery or breast recurrence. In 344 cases of breast-conserving surgery, disease recurred in 43 cases (12.5%), which were classified as follows: 17 cases of breast recurrence, 13 cases of breast and distant metastasis, and 13 cases of distant metastasis. Sixty-two patients (16.7%) received radiation therapy. A positive surgical margin and younger age were significant risk factors for breast recurrence in patients not receiving postoperative radiation therapy but not in patients receiving radiation therapy. Radiation therapy may be beneficial for younger patients with positive surgical margins. Furthermore, radiation therapy after recurrence was effective in the cases not treated with postoperative radiation but not in cases with inflammatory recurrence. Patients with breast recurrence alone had significantly higher survival rates than did patients with distant metastases regardless of breast recurrence. These findings suggest that the adaptation criteria of radiation therapy for local control must be clarified. (author)

  6. Clinical significance of radiation therapy in breast recurrence and prognosis in breast-conserving surgery

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Reiki; Nagao, Kazuharu; Miyayama, Haruhiko [Kumamoto City Hospital (Japan)] [and others

    1999-03-01

    Significant risk factors for recurrence of breast cancer after breast-conserving therapy, which has become a standard treatment for breast cancer, are positive surgical margins and the failure to perform radiation therapy. In this study, we evaluated the clinical significance of radiation therapy after primary surgery or breast recurrence. In 344 cases of breast-conserving surgery, disease recurred in 43 cases (12.5%), which were classified as follows: 17 cases of breast recurrence, 13 cases of breast and distant metastasis, and 13 cases of distant metastasis. Sixty-two patients (16.7%) received radiation therapy. A positive surgical margin and younger age were significant risk factors for breast recurrence in patients not receiving postoperative radiation therapy but not in patients receiving radiation therapy. Radiation therapy may be beneficial for younger patients with positive surgical margins. Furthermore, radiation therapy after recurrence was effective in the cases not treated with postoperative radiation but not in cases with inflammatory recurrence. Patients with breast recurrence alone had significantly higher survival rates than did patients with distant metastases regardless of breast recurrence. These findings suggest that the adaptation criteria of radiation therapy for local control must be clarified. (author)

  7. X-ray scatter signatures for enhanced breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kidane, Ghirmay; Speller, Robert; Royle, Gary [Medical Physics and Bioengineering Department, University College Landon, 11-20 Capper Street, London WC1E 6JA (United Kingdom)

    1999-12-31

    Conventional mammographic imaging suffers from a low specificity. The main cause is the small difference in the x-ray attenuation properties of healthy and diseased tissue leading to poor contrast in the image. It has been observed that additional information on breast tissue type can be obtained from x-ray diffraction effects. A study of excised normal and neoplastic breast tissue samples using x-ray diffraction apparatus has been observed that significant differences exist in the measured spectra between carcinoma and healthy tissue adjacent to the carcinoma. Such a difference allows tissue type to be characterised according to is diseased state. Furthermore the information can be applied to improve diagnosis. It is proposed that collection and analysis of the scattered x-rays present during a mammographic procedure can supply the additional information and be used to improve the image contrast. The ultimate aim of the project is to improve the specificity of x-ray mammography. (authors) 10 refs., 3 figs.

  8. Elastic scattering of gamma radiation in solids

    International Nuclear Information System (INIS)

    Goncalves, O.D.

    1987-01-01

    The elastic scattering of gamma rays in solids is studied: Rayleigh scattering as well as Bragg scattering in Laue geometries. We measured Rayleigh cross sections for U, Pb, Pt, W, Sn, Ag, Mo, Cd, Zn, and Cu with gamma energies ranging from 60 to 660 KeV and angles between 5 0 and 140 0 . The experimental data are compared with form factor theories and second order perturbation theories and the limits of validity of both are established. In the 60 KeV experiment, a competition between Rayleigh and Bragg effects is found in the region of low momentum transfer. The Bragg experiments were performed using the gamma ray diffractometer from the Hahn-Meitner Institut (Berlin) with gammas of 317 KeV and angles up to 2 0 . In particular, we studied the effect of annealing in nearly perfect Czochralski Silicon crystals with high perfection in the crystallographic structure. The results are compared with Kinematical and Dynamical theories. (author)

  9. Research of synchrotron radiation by virtual photon and compton scattering

    International Nuclear Information System (INIS)

    Meng Xianzhu

    2005-01-01

    This paper presents a new theory to explain the synchrotron radiation. When charged particle does circular motion in the accelerator, the magnetic field of the accelerator can be taken as periodic, and equivalent to virtual photon. By Compton scattering of virtual photon and charged particle, the virtual photon can be transformed into photon to radiate out. According to this theory, the formula of photon wavelength in synchrotron radiation is found out, and the calculation results of wavelength is consonant with experimental data. (author)

  10. Photophoresis and the scattering of electromagnetic radiation

    International Nuclear Information System (INIS)

    Ipser, J.R.

    1985-09-01

    Electron-microscope photographs of soot lend support to the picture in which a soot particle is modeled as a collection of chains of small carbon spheres. The soot particle itself is typically considerably larger than the small carbon spheres making up the chains. Thus the soot particles might have a size approx.0.1 - 1 μm while the small carbon spheres might have a size approx.0.03 μm in typical situations. Further, measurements of the density of soot yield values much less than that of normal carbon, indicating that an individual soot particle has a rather small filling factor, i.e., the fraction of the volume of the particle tht is occupied by chains. If a soot particle is taken to be a sphere partially filled with carbon chains, what are its scattering and absorption properties. Several workers have adopted the view that the net scattering and absorption properties can be determined simply by summing the cross-sections for the individual small carbon spheres. We feel that such a procedure cannot be valid in general because it neglects coherence effects among the various randomly located scatterers within the soot particle. It appears that in a first rough approximation the scattering and absorption properties of soot can be determined by estimating the effective dielectric constant of a soot sphere

  11. Breast conservation therapy for breast cancer. Radiation oncologist's point of view

    International Nuclear Information System (INIS)

    Hiraoka, Masahiro; Mitsumori, Michihide; Kokubo, Masaki; Fujishiro, Satsuki

    1998-01-01

    The roles and problems of radiation therapy in breast conserving therapy for breast cancer were presented. The roles of radiation therapy include decrease in breast recurrence, an alternative to axillary dissection for N0 cases, and neo-adjuvant radiation therapy. On the other hand, problems associated with radiation therapy are question of using radiation therapy for all cases, complications and worsening of cosmetics, and relatively high breast recurrence rates for margin-positive cases. The concept of breast conserving therapy is to improve QOL without decreasing treatment outcomes. It is considered that we should be more concentrated on the aspects of QOL because treatment outcomes of breast conserving therapy in Japan demonstrated sofar appear excellent. (author)

  12. Measuring scatter radiation in diagnostic x rays for radiation protection purposes

    International Nuclear Information System (INIS)

    Panayiotakis, George; Vlachos, Ioannis; Delis, Harry; Tsantilas, Xenophon; Kalyvas, Nektarios; Kandarakis, Ioannis

    2015-01-01

    During the last decades, radiation protection and dosimetry in medical X-ray imaging practice has been extensively studied. The purpose of this study was to measure secondary radiation in a conventional radiographic room, in terms of ambient dose rate equivalent H*(10) and its dependence on the radiographic exposure parameters such as X-ray tube voltage, tube current and distance. With some exceptions, the results indicated that the scattered radiation was uniform in the space around the water cylindrical phantom. The results also showed that the tube voltage and filtration affect the dose rate due to the scatter radiation. Finally, the scattered X-ray energy distribution was experimentally calculated. (authors)

  13. A software-based x-ray scatter correction method for breast tomosynthesis

    OpenAIRE

    Jia Feng, Steve Si; Sechopoulos, Ioannis

    2011-01-01

    Purpose: To develop a software-based scatter correction method for digital breast tomosynthesis (DBT) imaging and investigate its impact on the image quality of tomosynthesis reconstructions of both phantoms and patients.

  14. Astrophysical applications of Delbrück scattering: Dust scattered gamma radiation from gamma ray bursts

    International Nuclear Information System (INIS)

    Kunwar, B.; Bhadra, A.; Gupta, S.K. Sen

    2014-01-01

    A preliminary, and perhaps the first, study of astrophysical applications of Delbrück scattering in a gamma-ray emitting celestial object like a gamma-ray burst (GRB) has been made. At energies≥100 MeV the elastic scattering of gamma-ray photons off the molecular dust surrounding the GRB site is dominated by Delbrück scattering. Expressions for Delbrück-scattered gamma-ray flux as a function of time has been obtained for a few selected energies by assuming a simple model of GRB. These are compared with Compton-scattered flux. At certain situations, interestingly, the former is found to exceed the latter for the first few milliseconds of the burst. The issue of detectability of Delbrück-scattered gamma-ray echo from the cloud of a GRB is discussed. Although it is observed that the detection of such an echo is not within the capability of the presently operating gamma-ray missions such as Fermi LAT, a rough estimate shows that one can be optimistic that future generation gamma-ray telescopes might be able to see such photons' contribution to the total flux. - Highlights: ► Astrophysical application of Delbrück scattering in a GRB has been made. ► Initially, the Delbrück scattering may dominate the scattering of GeV γ-rays. ► The issue of detectability of such radiations is discussed

  15. Transient radiative transfer in a scattering slab considering polarization.

    Science.gov (United States)

    Yi, Hongliang; Ben, Xun; Tan, Heping

    2013-11-04

    The characteristics of the transient and polarization must be considered for a complete and correct description of short-pulse laser transfer in a scattering medium. A Monte Carlo (MC) method combined with a time shift and superposition principle is developed to simulate transient vector (polarized) radiative transfer in a scattering medium. The transient vector radiative transfer matrix (TVRTM) is defined to describe the transient polarization behavior of short-pulse laser propagating in the scattering medium. According to the definition of reflectivity, a new criterion of reflection at Fresnel surface is presented. In order to improve the computational efficiency and accuracy, a time shift and superposition principle is applied to the MC model for transient vector radiative transfer. The results for transient scalar radiative transfer and steady-state vector radiative transfer are compared with those in published literatures, respectively, and an excellent agreement between them is observed, which validates the correctness of the present model. Finally, transient radiative transfer is simulated considering the polarization effect of short-pulse laser in a scattering medium, and the distributions of Stokes vector in angular and temporal space are presented.

  16. Multiple scattering theory of radiative transfer in inhomogeneous atmospheres.

    Science.gov (United States)

    Kanal, M.

    1973-01-01

    In this paper we treat the multiple scattering theory of radiative transfer in plane-parallel inhomogeneous atmospheres. The treatment presented here may be adopted to model atmospheres characterized by an optical depth dependent coherent scattering phase function. For the purpose of illustration we consider the semi-infinite medium in which the absorption property of the atmosphere is characterized by an exponential function. The methodology employed here is the extension of the case treated previously by the author for homogeneous atmospheres.

  17. Interstellar scattering of pulsar radiation. Pt. 1

    International Nuclear Information System (INIS)

    Backer, D.C.

    1975-01-01

    An investigation of the intensity fluctuations of 28 pulsars near 0.4 GHz indicates that spectra of interstellar scintillation are consistent with a gaussian shape, that scintillation indices are near unity, and that scintillation bandwidth depends linearly on dispersion measure. Observations at cm wavelengths show that the observer is in the near field of the scattering medium for objects with the lowest dispersion measures, and confirm the step dependence of correlation bandwidth on dispersion measure found by Sutton (1971). The variation of scattering parameters with dispersion measure may indicate that the rms deviation of thermal electron density on the scale of 10 11 cm grows with path length through the galaxy. (orig.) [de

  18. Radiative MRI Coil Design Using Parasitic Scatterers

    DEFF Research Database (Denmark)

    Sanchez-Heredia, Juan D.; Avendal, Johan; Bibic, Adnan

    2018-01-01

    allows for antenna design techniques to be adapted to RF coil designs. This study proposes the use of parasitic scatterers to improve the performance of an existing 7T MRI coil called the single-sided adapted dipole (SSAD) antenna. The results reveal that scatterers arranged in a Yagi fashion can......Conventionally, radiofrequency (RF) coils used for magnetic resonance imaging (MRI) are electrically small and designed for nearfield operation. Therefore, existing antenna design techniques are mostly irrelevant for RF coils. However, the use of higher frequencies in ultrahigh field (UHF) MRI...... be applied to reduce local specific absorption rate (SAR) maxima of a reference SSAD by 40% with only a 6% decrease in the propagated B1 + field at the tissue depth of 15 cm. The higher directivity of the proposed design also decreasing the coupling with additional elements, making this antenna...

  19. Radiation osteitis following irradiation for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Langlands, A O; Souter, W A; Samuel, E; Redpath, A T [Royal Infirmary, Edinburgh (UK)

    1977-01-01

    Radiographs of the shoulder girdle were examined in 180 women who attended the breast follow-up clinic at the Department of Radiotherapy, Edinburgh. These comprised 52 controls who had been treated by radical mastectomy alone and 128 patients who had received post-operative X-ray therapy. The significance of osteoporosis as a sequel to irradiation is doubtful as it occurred in a substantial proportion of the control cases. Osteitis of severe degree occurred in 13.3% of patients who had been irradiated and was present in a mild form in a further 8.6%. The development of severe osteitis requires an NSD of 1650 rets or more. Estimates of the frequency of radiation osteitis are of no value unless detailed information is also provided about the techniques and quality of radiation.

  20. Effects of scattering anisotropy approximation in multigroup radiation shielding calculations

    International Nuclear Information System (INIS)

    Altiparmakov, D.

    1983-01-01

    Expansion of the scattering cross sections into Legendre series is the usual way of solving neutron transport problems. Because of the large space gradients of the neutron flux, the effects of that approximation become especially remarkable in the radiation shielding calculations. In this paper, a method taking into account the scattering anisotropy is presented. From the point od view of the accuracy and computing rate, the optimal approximation of the scattering anisotropy is established for the basic protective materials on the basis of simple problem calculations. (author)

  1. Hypofractionated Breast Radiation: Shorter Scheme, Lower Toxicity.

    Science.gov (United States)

    Linares, Isabel; Tovar, María Isabel; Zurita, Mercedes; Guerrero, Rosario; Expósito, Manuela; Del Moral, Rosario

    2016-08-01

    We analyzed the toxicity and cosmetic outcomes for patients who had undergone 3-dimensional conformal radiotherapy with a hypofractionated schedule and identified the risk factors associated with such a schedule. A total of 143 patients were treated for breast cancer (stage 0-III) with a hypofractionated radiation schedule after breast-conserving surgery from 2006 to 2011. Most patients received 42.4 Gy in 16 daily fractions, 2.65 Gy per fraction to the whole breast plus an additional simultaneous integrated or sequential boost to the tumor bed. The median follow-up period was 36 months. Mild acute skin toxicity was observed in 62%; 7% of the patients developed moderate skin toxicity, but no grade 4 toxicity was observed. The prevalence of fibrosis within the boost area was 5%, but no grade ≥ 2 was observed. The prevalence of fibrosis of any grade was greater in the nonboost (23%) than in the boost area. Of all the patients, 91% had good or excellent cosmetic outcomes. From the multivariate analysis, the incidence of epithelitis correlated with the patient's treated volume (P = .044). The incidence of acute toxicity correlated with the boost type to the tumor bed and the total treatment dose (P = .012 and P = .002, respectively). Also, a poor to fair cosmetic outcome was significantly associated statistically with the surgery type (P = .05), boost type (P = .004), and total dose (P = .001). Delivering whole-breast irradiation with a hypofractionated schedule of 42.4 Gy plus a simultaneous integrated boost to the tumor bed appears to be a safe and effective technique, with good cosmetic results and lower toxicity. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Interaction between radiation and other breast cancer risk factors

    International Nuclear Information System (INIS)

    Boice, J.D. Jr.; Stone, B.J.

    1978-01-01

    A follow-up study was conducted of 1764 women institutionalized for pulmonary tuberculosis between 1930 and 1954. Among 1047 women exposed to fluoroscopic chest X-rays during air collapse therapy of the lung, an excess of breast cancer was observed and previously reported (41 cases observed versus 23.3 expected). Among 717 comparison patients who received other treatments, no excess breast cancer risk was apparent (15 cases observed versus 14.1 expected). To determine whether breast cancer risk factors modify the carcinogenic effect of radiation, analyses were performed evaluating the interaction of radiation with indicators of breast cancer risk. The greatest radiation risk was found when radiation exposure occurred just before and during menarche. Similarly, exposures during first pregnancy appeared substantially more hazardous than exposures occurring before or after first pregnancy, suggesting that the condition of the breast at the time of pregnancy modifies the effect of radiation in such a way as to enhance the risk. Age at menopause did not appear to influence the risk of radiation exposure. Other than radiation, benign breast disease was the most significant breast cancer risk indicator. Benign breast disease was not seen to modify the effect of radiation exposure; however, excessive radiation exposure might have increased the incidence of benign breast disease, complicating the interaction analysis. Because of the uncertainty due to small-number sampling variation, these study results will require confirmation by a larger series. They do, however, suggest that stages when breast tissue undergoes high mitotic activity, e.g. menarche and pregnancy, are times of special vulnerability to the harmful effects of ionizing radiation

  3. Power spectrum analysis of the x-ray scatter signal in mammography and breast tomosynthesis projections.

    Science.gov (United States)

    Sechopoulos, Ioannis; Bliznakova, Kristina; Fei, Baowei

    2013-10-01

    To analyze the frequency domain characteristics of the signal in mammography images and breast tomosynthesis projections with patient tissue texture due to detected scattered x-rays. Acquisitions of x-ray projection images of 19 different patient breasts were simulated using previously acquired volumetric patient images. Acquisition of these images was performed with a dedicated breast CT prototype system, and the images were classified into voxels representing skin, adipose, and glandular tissue with a previously validated automated algorithm. The classified three dimensional images then underwent simulated mechanical compression representing that which is performed during acquisition of mammography and breast tomosynthesis images. The acquisition of projection images of each patient breast was simulated using Monte Carlo methods with each simulation resulting in two images: one of the primary (non-scattered) signal and one of the scatter signal. To analyze the scatter signal for both mammography and breast tomosynthesis, two projections images of each patient breast were simulated, one with the x-ray source positioned at 0° (mammography and central tomosynthesis projection) and at 30° (wide tomosynthesis projection). The noise power spectra (NPS) for both the scatter signal alone and the total signal (primary + scatter) for all images were obtained and the combined results of all patients analyzed. The total NPS was fit to the expected power-law relationship NPS(f) = k/f β and the results were compared with those previously published on the power spectrum characteristics of mammographic texture. The scatter signal alone was analyzed qualitatively and a power-law fit was also performed. The mammography and tomosynthesis projections of three patient breasts were too small to analyze, so a total of 16 patient breasts were analyzed. The values of β for the total signal of the 0° projections agreed well with previously published results. As expected, the scatter

  4. Nonlinear Scattering of VLF Waves in the Radiation Belts

    Science.gov (United States)

    Crabtree, Chris; Rudakov, Leonid; Ganguli, Guru; Mithaiwala, Manish

    2014-10-01

    Electromagnetic VLF waves, such as whistler mode waves, control the lifetime of trapped electrons in the radiation belts by pitch-angle scattering. Since the pitch-angle scattering rate is a strong function of the wave properties, a solid understanding of VLF wave sources and propagation in the magnetosphere is critical to accurately calculate electron lifetimes. Nonlinear scattering (Nonlinear Landau Damping) is a mechanism that can strongly alter VLF wave propagation [Ganguli et al. 2010], primarily by altering the direction of propagation, and has not been accounted for in previous models of radiation belt dynamics. Laboratory results have confirmed the dramatic change in propagation direction when the pump wave has sufficient amplitude to exceed the nonlinear threshold [Tejero et al. 2014]. Recent results show that the threshold for nonlinear scattering can often be met by naturally occurring VLF waves in the magnetosphere, with wave magnetic fields of the order of 50-100 pT inside the plasmapause. Nonlinear scattering can then dramatically alter the macroscopic dynamics of waves in the radiation belts leading to the formation of a long-lasting wave-cavity [Crabtree et al. 2012] and, when amplification is present, a multi-pass amplifier [Ganguli et al. 2012]. By considering these effects, the lifetimes of electrons can be dramatically reduced. This work is supported by the Naval Research Laboratory base program.

  5. Scattered radiation from applicators in clinical electron beams.

    NARCIS (Netherlands)

    Battum, L.J. van; Zee, W. van der; Huizenga, H.

    2003-01-01

    In radiotherapy with high-energy (4-25 MeV) electron beams, scattered radiation from the electron applicator influences the dose distribution in the patient. In most currently available treatment planning systems for radiotherapy this component is not explicitly included and handled only by a slight

  6. Analysis and characterization. Nuclear resonant scattering with the synchrotron radiation

    International Nuclear Information System (INIS)

    Ruffer, R.; Teillet, J.

    2003-01-01

    The nuclear resonant scattering using the synchrotron radiation combines the uncommon properties of the Moessbauer spectroscopy and those of the synchrotron radiation. Since its first observation in 1984, this technique and its applications have been developed rapidly. The nuclear resonant scattering is now a standard technique for all the synchrotron radiation sources of the third generation. As the Moessbauer spectroscopy, it is a method of analysis at the atomic scale and a non destructive method. It presents the advantage not to require the use of radioactive sources of incident photons which can be difficult to make, of a lifetime which can be short and of an obviously limited intensity. The current applications are the hyperfine spectroscopy and the structural dynamics. In hyperfine spectroscopy, the nuclear resonant scattering can measure the same size than the Moessbauer spectroscopy. Nevertheless, it is superior in the ranges which exploit the specific properties of the synchrotron radiation, such as the very small samples, the monocrystals, the measures under high pressures, the geometry of small angle incidence for surfaces and multilayers. The structural dynamics, in a time scale of the nanosecond to the microsecond can be measured in the temporal scale. Moreover, the nuclear inelastic scattering gives for the first time a tool which allows to have directly the density of states of phonons and then allow to deduce the dynamical and thermodynamical properties of the lattice. The nuclear resonant scattering technique presented here, which corresponds to the Moessbauer spectroscopy technique (SM), is called 'nuclear forward scattering' (NFS). Current applications in physics and chemistry are develop. The NFS is compared to the usual SM technique in order to reveal its advantages and disadvantages. (O.M.)

  7. Altitude Registration of Limb-Scattered Radiation

    Science.gov (United States)

    Moy, Leslie; Bhartia, Pawan K.; Jaross, Glen; Loughman, Robert; Kramarova, Natalya; Chen, Zhong; Taha, Ghassan; Chen, Grace; Xu, Philippe

    2017-01-01

    One of the largest constraints to the retrieval of accurate ozone profiles from UV backscatter limb sounding sensors is altitude registration. Two methods, the Rayleigh scattering attitude sensing (RSAS) and absolute radiance residual method (ARRM), are able to determine altitude registration to the accuracy necessary for long-term ozone monitoring. The methods compare model calculations of radiances to measured radiances and are independent of onboard tracking devices. RSAS determines absolute altitude errors, but, because the method is susceptible to aerosol interference, it is limited to latitudes and time periods with minimal aerosol contamination. ARRM, a new technique introduced in this paper, can be applied across all seasons and altitudes. However, it is only appropriate for relative altitude error estimates. The application of RSAS to Limb Profiler (LP) measurements from the Ozone Mapping and Profiler Suite (OMPS) on board the Suomi NPP (SNPP) satellite indicates tangent height (TH) errors greater than 1 km with an absolute accuracy of +/-200 m. Results using ARRM indicate a approx. 300 to 400m intra-orbital TH change varying seasonally +/-100 m, likely due to either errors in the spacecraft pointing or in the geopotential height (GPH) data that we use in our analysis. ARRM shows a change of approx. 200m over 5 years with a relative accuracy (a long-term accuracy) of 100m outside the polar regions.

  8. Four cases of radiation pneumonia after breast conservative therapy for breast cancer

    International Nuclear Information System (INIS)

    Horii, Rie; Fukuuchi, Atushi; Nishi, Tsunehiro

    1997-01-01

    Between 1983 and 1996, a series of 240 patients with early stage breast cancer were treated with breast conservative treatment, and 201 patients of them all received irradiation at a dose of 46-60 Gy to the affected breast. Among the 201 patients who received breast irradiation, four (2.0%) patients experienced radiation pneumonia. These four patients with radiation pneumonia presented with coughing from 7 to 20 weeks after irradiation. Chest X-ray film revealed interstitial pneumonia in a lung field where coincided with the irradiated field in them. Three out of four patients demanded steroids, but all patients got well within 4 months. Radiation pneumonia following conservative surgery and radiotherapy for breast cancer is an infrequent complication, but attention should be paid to radiation pneumonia if the patient suffers from persistent coughing after radiotherapy. (author)

  9. Breast reconstruction and post-mastectomy radiation practice

    International Nuclear Information System (INIS)

    Chen, Susie A; Hiley, Crispin; Nickleach, Dana; Petsuksiri, Janjira; Andic, Fundagul; Riesterer, Oliver; Switchenko, Jeffrey M; Torres, Mylin A

    2013-01-01

    The goal of this study was to explore the perspectives and practice of radiation oncologists who treat breast cancer patients who have had breast reconstruction. In 2010, an original electronic survey was sent to all physician members of the American Society of Radiation Oncology, National Cancer Research Institute-Breast Cancer Studies Group in the United Kingdom, Thai Society of Therapeutic Radiology and Oncology, Swiss Society of Radiation Oncology, and Turkish Radiation Oncology Society. We identified factors associated with radiation oncologists who treat breast cancer patients with reconstruction performed prior to radiation and obtained information regarding radiation management of the breast reconstruction. 358 radiation oncologists responded, and 60% of the physicians were from the United States. While 64% of participants agree or strongly agree that breast image affects a woman’s quality of life during radiation, 57% feel that reconstruction challenges their ability to deliver effective breast radiation. Compared with other countries, treatment within the United States was associated with a high reconstruction rate (>/= 50% of mastectomy patients) prior to radiation (p < 0.05). Delayed-immediate reconstruction with a temporary tissue expander was more common in the United States than in other countries (52% vs. 23%, p = 0.01). Among physicians who treat patients with tissue expanders, the majority (60%) prefer a moderately inflated implant with 150-250 cc of fluid rather than a completely deflated (13%) or inflated expander (28%) during radiation. Among radiation oncologists who treat reconstructions, 49% never use bolus and 40% never boost a breast reconstruction. United States physicians were more likely than physicians from other countries to boost or bolus the reconstruction irrespective of the type of reconstruction seen in their clinic patients (p < 0.01). Great variation in practice is evident from our study of radiation treatment for breast

  10. Radiation-induced morphea of the breast: a case report

    Directory of Open Access Journals (Sweden)

    Cheah Nellie LC

    2008-04-01

    Full Text Available Abstract Radiation-induced morphea (RIM of the breast is a rare complication of radiotherapy. It is disfiguring, painful and defeats the purpose of achieving a good cosmesis in breast-conservation surgery. This report describes a severe case of RIM in a breast cancer patient together with photographic illustrations of the serial changes over time and histopathology slides. A review of the literature is provided.

  11. UV Irradiance Enhancements by Scattering of Solar Radiation from Clouds

    Directory of Open Access Journals (Sweden)

    Uwe Feister

    2015-08-01

    Full Text Available Scattering of solar radiation by clouds can reduce or enhance solar global irradiance compared to cloudless-sky irradiance at the Earth’s surface. Cloud effects to global irradiance can be described by Cloud Modification Factors (CMF. Depending on strength and duration, irradiance enhancements affect the energy balance of the surface and gain of solar power for electric energy generation. In the ultraviolet region, they increase the risk for damage to living organisms. Wavelength-dependent CMFs have been shown to reach 1.5 even in the UV-B region at low altitudes. Ground-based solar radiation measurements in the high Andes region at altitudes up to 5917 m a.s.l showed cloud-induced irradiance enhancements. While UV-A enhancements were explained by cloud scattering, both radiation scattering from clouds and Negative Ozone Anomalies (NOA have been discussed to have caused short-time enhancement of UV-B irradiance. Based on scenarios using published CMF and additional spectroradiometric measurements at a low-altitude site, the contribution of cloud scattering to the UV-B irradiance enhancement in the Andes region has been estimated. The range of UV index estimates converted from measured UV-B and UV-A irradiance and modeled cloudless-sky ratios UV-B/erythemal UV is compatible with an earlier estimate of an extreme UV index value of 43 derived for the high Andes.

  12. Radiation of ultrarelativistic charge taking into account for multiple scattering

    International Nuclear Information System (INIS)

    Yang, C.

    1977-01-01

    A brief theoretical review of characteristics of X-rays and more hard radiation formed by an ultrarelativistic charged particle passing through a plate or a stack of plates with regard for multiple scattering and the plate material absorptivity is made. Formulas for frequency- angular and frequency distributions of total radiation in the cases of a plate and of a stack of plates with large spacings as well as a stack of sufficiently thick plates are given. A calculation method for the radiation distributions in a general case of an arbitrary stack is pointed out. The frequency distribution of the total radiation consisting of bremsstrahlung and boundary effects is analyzed in detail. A problem of experimental separation of the boundary effect from the total radiation is discussed

  13. Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties

    Energy Technology Data Exchange (ETDEWEB)

    Tadayyon, Hadi [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, Faculty of Medicine, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Sadeghi-Naini, Ali; Czarnota, Gregory, E-mail: Gregory.Czarnota@sunnybrook.ca [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, Faculty of Medicine, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Radiation Oncology, Faculty of Medicine, University of Toronto, Toronto, Ontario M5T 1P5 (Canada); Wirtzfeld, Lauren [Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Wright, Frances C. [Division of Surgical Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada)

    2014-01-15

    Purpose: Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. Methods: Ultrasound images and radiofrequency data from 42 locally advanced breast cancer patients were acquired and analyzed. Parameters related to the linear regression of the power spectrum—midband fit, slope, and 0-MHz-intercept—were determined from breast tumors and normal breast tissues. Mean scatterer spacing was estimated from the spectral autocorrelation, and the effective scatterer diameter and effective acoustic concentration were estimated from the Gaussian form factor. Parametric maps of each quantitative ultrasound parameter were constructed from the gated radiofrequency segments in tumor and normal tissue regions of interest. In addition to the mean values of the parametric maps, higher order statistical features, computed from gray-level co-occurrence matrices were also determined and used for characterization. Finally, linear and quadratic discriminant analyses were performed using combinations of quantitative ultrasound parameters to classify breast tissues. Results: Quantitative ultrasound parameters were found to be statistically different between tumor and normal tissue (p < 0.05). The combination of effective acoustic concentration and mean scatterer spacing could separate tumor from normal tissue with 82% accuracy, while the addition of effective scatterer diameter to the combination did not provide significant improvement (83% accuracy). Furthermore, the two advanced parameters, including effective scatterer diameter and mean scatterer spacing, were found to be statistically differentiating among grade I, II, and III tumors (p = 0.014 for scatterer spacing, p = 0.035 for effective scatterer diameter). The separation of the tumor

  14. Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties

    International Nuclear Information System (INIS)

    Tadayyon, Hadi; Sadeghi-Naini, Ali; Czarnota, Gregory; Wirtzfeld, Lauren; Wright, Frances C.

    2014-01-01

    Purpose: Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. Methods: Ultrasound images and radiofrequency data from 42 locally advanced breast cancer patients were acquired and analyzed. Parameters related to the linear regression of the power spectrum—midband fit, slope, and 0-MHz-intercept—were determined from breast tumors and normal breast tissues. Mean scatterer spacing was estimated from the spectral autocorrelation, and the effective scatterer diameter and effective acoustic concentration were estimated from the Gaussian form factor. Parametric maps of each quantitative ultrasound parameter were constructed from the gated radiofrequency segments in tumor and normal tissue regions of interest. In addition to the mean values of the parametric maps, higher order statistical features, computed from gray-level co-occurrence matrices were also determined and used for characterization. Finally, linear and quadratic discriminant analyses were performed using combinations of quantitative ultrasound parameters to classify breast tissues. Results: Quantitative ultrasound parameters were found to be statistically different between tumor and normal tissue (p < 0.05). The combination of effective acoustic concentration and mean scatterer spacing could separate tumor from normal tissue with 82% accuracy, while the addition of effective scatterer diameter to the combination did not provide significant improvement (83% accuracy). Furthermore, the two advanced parameters, including effective scatterer diameter and mean scatterer spacing, were found to be statistically differentiating among grade I, II, and III tumors (p = 0.014 for scatterer spacing, p = 0.035 for effective scatterer diameter). The separation of the tumor

  15. Breast Cancer After Chest Radiation Therapy for Childhood Cancer

    Science.gov (United States)

    Moskowitz, Chaya S.; Chou, Joanne F.; Wolden, Suzanne L.; Bernstein, Jonine L.; Malhotra, Jyoti; Friedman, Danielle Novetsky; Mubdi, Nidha Z.; Leisenring, Wendy M.; Stovall, Marilyn; Hammond, Sue; Smith, Susan A.; Henderson, Tara O.; Boice, John D.; Hudson, Melissa M.; Diller, Lisa R.; Bhatia, Smita; Kenney, Lisa B.; Neglia, Joseph P.; Begg, Colin B.; Robison, Leslie L.; Oeffinger, Kevin C.

    2014-01-01

    Purpose The risk of breast cancer is high in women treated for a childhood cancer with chest irradiation. We sought to examine variations in risk resulting from irradiation field and radiation dose. Patients and Methods We evaluated cumulative breast cancer risk in 1,230 female childhood cancer survivors treated with chest irradiation who were participants in the CCSS (Childhood Cancer Survivor Study). Results Childhood cancer survivors treated with lower delivered doses of radiation (median, 14 Gy; range, 2 to 20 Gy) to a large volume (whole-lung field) had a high risk of breast cancer (standardized incidence ratio [SIR], 43.6; 95% CI, 27.2 to 70.3), as did survivors treated with high doses of delivered radiation (median, 40 Gy) to the mantle field (SIR, 24.2; 95% CI, 20.7 to 28.3). The cumulative incidence of breast cancer by age 50 years was 30% (95% CI, 25 to 34), with a 35% incidence among Hodgkin lymphoma survivors (95% CI, 29 to 40). Breast cancer–specific mortality at 5 and 10 years was 12% (95% CI, 8 to 18) and 19% (95% CI, 13 to 25), respectively. Conclusion Among women treated for childhood cancer with chest radiation therapy, those treated with whole-lung irradiation have a greater risk of breast cancer than previously recognized, demonstrating the importance of radiation volume. Importantly, mortality associated with breast cancer after childhood cancer is substantial. PMID:24752044

  16. Influences of scattering radiation in a TLD irradiation room, 2

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Suwa, Shigeo

    1985-01-01

    The influence of scattering radiation (SR) on radiation dose rate (DR) in a TLD irradiation room was assessed. A single SD from a standard TLD apparatus, i.e., an acrylic or aluminum table, was examined. The maximum DR was attained at approximately 80 cm from the radiation source. Energy spectra of SR ranged up to the energy of direct radiation beam. Circular SD at one m from the radiation source, which contributed to DR to the direct radiation beam, was almost homogeneous. SD was large near the irradiation table, and the influence of SD on DR became smaller with SD being vertically farther from the apparatus. The influence of SD on RD to the direct radiation beam became less with an increase in gamma ray energy. At one m from the radiation source, 6 - 7 % of SD contributed to DR to the direct radiation beam for 0.662 MeV of gamma ray. This figure was one half of that with NaI (Tl) scintillation detector. (Namekawa, K.)

  17. Breast Intensity-Modulated Radiation Therapy Reduces Time Spent With Acute Dermatitis for Women of All Breast Sizes During Radiation

    International Nuclear Information System (INIS)

    Freedman, Gary M.; Li Tianyu; Nicolaou, Nicos; Chen Yan; Ma, Charlie C.-M.; Anderson, Penny R.

    2009-01-01

    Purpose: To study the time spent with radiation-induced dermatitis during a course of radiation therapy for breast cancer in women treated with conventional or intensity-modulated radiation therapy (IMRT). Methods and Materials: The study population consisted of 804 consecutive women with early-stage breast cancer treated with breast-conserving surgery and radiation from 2001 to 2006. All patients were treated with whole-breast radiation followed by a boost to the tumor bed. Whole-breast radiation consisted of conventional wedged photon tangents (n = 405) earlier in the study period and mostly of photon IMRT (n = 399) in later years. All patients had acute dermatitis graded each week of treatment. Results: The breakdown of the cases of maximum acute dermatitis by grade was as follows: 3%, Grade 0; 34%, Grade 1; 61%, Grade 2; and 2%, Grade 3. The breakdown of cases of maximum toxicity by technique was as follows: 48%, Grade 0/1, and 52%, Grade 2/3, for IMRT; and 25%, Grade 0/1, and 75%, Grade 2/3, for conventional radiation therapy (p < 0.0001). The IMRT patients spent 82% of weeks during treatment with Grade 0/1 dermatitis and 18% with Grade 2/3 dermatitis, compared with 29% and 71% of patients, respectively, treated with conventional radiation (p < 0.0001). Furthermore, the time spent with Grade 2/3 toxicity was decreased in IMRT patients with small (p = 0.0015), medium (p < 0.0001), and large (p < 0.0001) breasts. Conclusions: Breast IMRT is associated with a significant decrease both in the time spent during treatment with Grade 2/3 dermatitis and in the maximum severity of dermatitis compared with that associated with conventional radiation, regardless of breast size.

  18. Radiative corrections to neutrino deep inelastic scattering revisited

    International Nuclear Information System (INIS)

    Arbuzov, Andrej B.; Bardin, Dmitry Yu.; Kalinovskaya, Lidia V.

    2005-01-01

    Radiative corrections to neutrino deep inelastic scattering are revisited. One-loop electroweak corrections are re-calculated within the automatic SANC system. Terms with mass singularities are treated including higher order leading logarithmic corrections. Scheme dependence of corrections due to weak interactions is investigated. The results are implemented into the data analysis of the NOMAD experiment. The present theoretical accuracy in description of the process is discussed

  19. On the radiative corrections to the neutrino deep inelastic scattering

    International Nuclear Information System (INIS)

    Bardin, D.Yu.; Dokuchaeva, V.A.

    1986-01-01

    A unique set of formulae is presented for the radiative corrections to the double differential cross section of deep inelastic neutrino scattering in channels of charged and neutral currents within a simple quark parton model in a renormalization scheme on mass-shell. It is shown that these cross sections when being integrated up to the one-dimensional distribution or up to the total cross section reproduce many results existing in the literature

  20. Scattering in an intense radiation field: Time-independent methods

    International Nuclear Information System (INIS)

    Rosenberg, L.

    1977-01-01

    The standard time-independent formulation of nonrelativistic scattering theory is here extended to take into account the presence of an intense external radiation field. In the case of scattering by a static potential the extension is accomplished by the introduction of asymptotic states and intermediate-state propagators which account for the absorption and induced emission of photons by the projectile as it propagates through the field. Self-energy contributions to the propagator are included by a systematic summation of forward-scattering terms. The self-energy analysis is summarized in the form of a modified perturbation expansion of the type introduced by Watson some time ago in the context of nuclear-scattering theory. This expansion, which has a simple continued-fraction structure in the case of a single-mode field, provides a generally applicable successive approximation procedure for the propagator and the asymptotic states. The problem of scattering by a composite target is formulated using the effective-potential method. The modified perturbation expansion which accounts for self-energy effects is applicable here as well. A discussion of a coupled two-state model is included to summarize and clarify the calculational procedures

  1. Inelastic scattering in condensed matter with high intensity moessbauer radiation

    International Nuclear Information System (INIS)

    Yelon, W.B.; Schupp, G.

    1991-05-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is not fully operational at the University of Missouri Research Reactor (MURR) as well as a facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using Bragg scattering filters to suppress unwanted radiation. These have led to a Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to make a novel independent determination of interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na metal and the charge density wave satellite reflection Debye-Waller factor in TaS 2 , which indicate phason rather than phonon behavior. Using a specially constructed sample cell which enables us to vary temperatures from -10 C to 110 C, we have begun quasielastic diffusion studies in viscous liquids and current results are summarized. Included are the temperature and Q dependence of the scattering in pentadecane and diffusion in glycerol

  2. Radiation detection and diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Dodd, G.D.

    1981-01-01

    The value of mammography in the symptomatic patient has been adequately documented, but its use as a detection procedure remains a question. Risk-benefit ratios, based primarily upon the study carried out by the Health Insurance Plan of Greater New York, have suggested that the technique has little value in individuals under age 50. Emphasis has been placed upon the possible carcinogenic effects of radiation as compared with the efficacy of mammography and the questionable influence of early diagnosis upon end results. Although technical advances have substantially reduced the exposure of the patient to radiation, the possibility of significant information loss as the result of these developments has been considered a potential drawback to their routine use. All of these factors have served to diminish both public and professional acceptance of the examination. Although current data do not allow complete resolution of these problems, certain conclusions may be drawn and trends established. The sum of these may indicate that minimal dose mammography is an accurate, low-risk procedure, capable of significantly altering the natural history of breast cancer. Whether or not the examination should be routinely used in women under age 50 remains open to question since the lack of experimental controls prohibits validation of the technique in terms of reduced mortality rates. Documentation of increased survival rates may partially assist in the established of a reliable risk-benefit ratio, but will not satisfy the statistical requirements of eliminating lead-bias, and self-selection. These questions may be resolved by studies now underway

  3. Primary radiation therapy for early breast cancer: the experience at the joint center for radiation therapy

    International Nuclear Information System (INIS)

    Harris, J.R.; Botnick, L.; Bloomer, W.D.; Chaffey, J.T.; Hellman, S.

    1981-01-01

    The results of primary radiation therapy in 176 consecutive patients with clinical State I and II carcinoma of the breast were reviewed. Median follow-up time was 47 months. The overall breast relapse rate was 7%. Patients undergoing interstitial implantation had a significantly lower breast relapse rate (1%) than patients not undergoing implantation (11%). Breast relapse was more common in patients undergoing incisional or needle biopsy (17%), compared to patients treated after excisional biopsy (5%). In patients undergoing excisional biopsy, but not interstitial implantation, breast relapse was related to external beam dose. Twelve percent of the patients who received less than 1600 ret dose relapsed in the breast, compared to none of the 19 patients who received more than 1700 ret dose. These results imply that supplemental irradiation to the primary tumor area is required following excisional biopsy of a primary breast cancer when 4500-5000 rad is delivered to the entire breast

  4. Polarized scattered light from self-luminous exoplanets. Three-dimensional scattering radiative transfer with ARTES

    Science.gov (United States)

    Stolker, T.; Min, M.; Stam, D. M.; Mollière, P.; Dominik, C.; Waters, L. B. F. M.

    2017-11-01

    Context. Direct imaging has paved the way for atmospheric characterization of young and self-luminous gas giants. Scattering in a horizontally-inhomogeneous atmosphere causes the disk-integrated polarization of the thermal radiation to be linearly polarized, possibly detectable with the newest generation of high-contrast imaging instruments. Aims: We aim to investigate the effect of latitudinal and longitudinal cloud variations, circumplanetary disks, atmospheric oblateness, and cloud particle properties on the integrated degree and direction of polarization in the near-infrared. We want to understand how 3D atmospheric asymmetries affect the polarization signal in order to assess the potential of infrared polarimetry for direct imaging observations of planetary-mass companions. Methods: We have developed a three-dimensional Monte Carlo radiative transfer code (ARTES) for scattered light simulations in (exo)planetary atmospheres. The code is applicable to calculations of reflected light and thermal radiation in a spherical grid with a parameterized distribution of gas, clouds, hazes, and circumplanetary material. A gray atmosphere approximation is used for the thermal structure. Results: The disk-integrated degree of polarization of a horizontally-inhomogeneous atmosphere is maximal when the planet is flattened, the optical thickness of the equatorial clouds is large compared to the polar clouds, and the clouds are located at high altitude. For a flattened planet, the integrated polarization can both increase or decrease with respect to a spherical planet which depends on the horizontal distribution and optical thickness of the clouds. The direction of polarization can be either parallel or perpendicular to the projected direction of the rotation axis when clouds are zonally distributed. Rayleigh scattering by submicron-sized cloud particles will maximize the polarimetric signal whereas the integrated degree of polarization is significantly reduced with micron

  5. SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R [Durham, NC (United States); Lakshmanan, M; Fong, G; Kapadia, A [Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States); Greenberg, J [Duke University, Durham, NC (United States)

    2016-06-15

    Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to

  6. Coronary artery calcium in breast cancer survivors after radiation therapy

    NARCIS (Netherlands)

    Takx, Richard A P; Vliegenthart, Rozemarijn; Schoepf, U Joseph; Pilz, Lothar R; Schoenberg, Stefan O; Morris, Pamela B; Henzler, Thomas; Apfaltrer, Paul

    The purpose of the current study is to investigate whether breast cancer survivors after radiation therapy have a higher burden of coronary artery calcium as a potential surrogate of radiation-induced accelerated coronary artery disease. 333 patients were included. 54 patients underwent chest CT ae

  7. Inelastic scattering in condensed matter with high intensity Moessbauer radiation

    International Nuclear Information System (INIS)

    Yelon, W.B.; Schupp, G.

    1990-10-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS 2 , which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support

  8. Gamma scattering in condensed matter with high intensity Moessbauer radiation

    International Nuclear Information System (INIS)

    1990-01-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as a facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS 2 , which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support

  9. Radiation induced cancer risk estimation for contralateral breast in 3D conformal treatments of post mastectomy cancer patients: based on OED

    International Nuclear Information System (INIS)

    Hemalatha, A.; Athiyaman, M.; Kumar, H.S.; Chougule, Arun

    2016-01-01

    A global comparison of breast cancer in India with other countries like US/China in 2012 gave a data that collectively the above countries including India account for almost one third of global breast cancer burden. According to this report for every two women newly diagnosed with breast cancer in India, one lady is dying of it. The curative radiotherapy for breast cancer treatment associated with scattered and leakage radiation exposure to critical organs like contralateral breast, lung etc. Radiation is one of the well known carcinogen of breast due its high radiosensititvity. The study done by Stovall et al concluded that the contralateral breast cancer risk is elevated for breast cancer patients of age less than 40 years if dose to health breast is greater than 1 Gy. So its necessary to evaluate dose to Contralateral Breast (ClB) for breast cancer patients for more than 1 Gy. The aim of this study is to compare the risks of secondary breast cancer from conventional wedge field and forward IMRT technique using the concept of OED-Organ Equivalent Dose/for chest wall irradiation of post mastectomy breast cancer patients

  10. Radiation and breast cancer: a review of current evidence

    International Nuclear Information System (INIS)

    Ronckers, Cécile M; Erdmann, Christine A; Land, Charles E

    2005-01-01

    This paper summarizes current knowledge on ionizing radiation-associated breast cancer in the context of established breast cancer risk factors, the radiation dose–response relationship, and modifiers of dose response, taking into account epidemiological studies and animal experiments. Available epidemiological data support a linear dose–response relationship down to doses as low as about 100 mSv. However, the magnitude of risk per unit dose depends strongly on when radiation exposure occurs: exposure before the age of 20 years carries the greatest risk. Other characteristics that may influence the magnitude of dose-specific risk include attained age (that is, age at observation for risk), age at first full-term birth, parity, and possibly a history of benign breast disease, exposure to radiation while pregnant, and genetic factors

  11. Calculation and Measurement of Low-Energy Radiative Moller Scattering

    Science.gov (United States)

    Epstein, Charles; DarkLight Collaboration

    2017-09-01

    A number of current nuclear physics experiments have come to rely on precise knowledge of electron-electron (Moller) and positron-electron (Bhabha) scattering. Some of these experiments, having lepton beams on targets containing atomic electrons, use these purely-QED processes as normalization. In other scenarios, with electron beams at low energy and very high intensity, Moller scattering and radiative Moller scattering have such enormous cross-sections that the backgrounds they produce must be understood. In this low-energy regime, the electron mass is also not negligible in the calculation of the cross section. This is important, for example, in the DarkLight experiment (100 MeV). As a result, we have developed a new event generator for the radiative Moller and Bhabha processes, with new calculations that keep all terms of the electron mass. The MIT High Voltage Research Laboratory provides us a unique opportunity to study this process experimentally and compare it with our work, at a low beam energy of 2.5 MeV where the effects of the electron mass are significant. We are preparing a dedicated apparatus consisting of a magnetic spectrometer in order to directly measure this process. An overview of the calculation and the status of the experiment will be presented.

  12. Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study

    International Nuclear Information System (INIS)

    Juneja, Prabhjot; Harris, Emma J.; Kirby, Anna M.; Evans, Philip M.

    2012-01-01

    Purpose: To validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (CT) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. Methods and Materials: Twenty-four patients receiving postlumpectomy radiation therapy for breast cancer underwent CT imaging in prone and supine positions. The whole-breast clinical target volume was outlined. Clinical target volumes were segmented into fibroglandular and fatty tissue using the following algorithms: physical density thresholding; interactive thresholding; fuzzy c-means with 3 classes (FCM3) and 4 classes (FCM4); and k-means. The segmentation algorithms were evaluated in 2 stages: first, an approach based on the assumption that the breast composition should be the same in both prone and supine position; and second, comparison of segmentation with tissue outlines from 3 experts using the Dice similarity coefficient (DSC). Breast datasets were grouped into nonsparse and sparse fibroglandular tissue distributions according to expert assessment and used to assess the accuracy of the segmentation methods and the agreement between experts. Results: Prone and supine breast composition analysis showed differences between the methods. Validation against expert outlines found significant differences (P<.001) between FCM3 and FCM4. Fuzzy c-means with 3 classes generated segmentation results (mean DSC = 0.70) closest to the experts' outlines. There was good agreement (mean DSC = 0.85) among experts for breast tissue outlining. Segmentation accuracy and expert agreement was significantly higher (P<.005) in the nonsparse group than in the sparse group. Conclusions: The FCM3 gave the most accurate segmentation of breast tissues on CT data and could therefore be used in adaptive radiation therapy-based on tissue modeling. Breast tissue segmentation

  13. Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study

    Energy Technology Data Exchange (ETDEWEB)

    Juneja, Prabhjot, E-mail: Prabhjot.Juneja@icr.ac.uk [Joint Department of Physics, Institute of Cancer Research, Sutton (United Kingdom); Harris, Emma J. [Joint Department of Physics, Institute of Cancer Research, Sutton (United Kingdom); Kirby, Anna M. [Department of Academic Radiotherapy, Royal Marsden National Health Service Foundation Trust, Sutton (United Kingdom); Evans, Philip M. [Joint Department of Physics, Institute of Cancer Research, Sutton (United Kingdom)

    2012-11-01

    Purpose: To validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (CT) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. Methods and Materials: Twenty-four patients receiving postlumpectomy radiation therapy for breast cancer underwent CT imaging in prone and supine positions. The whole-breast clinical target volume was outlined. Clinical target volumes were segmented into fibroglandular and fatty tissue using the following algorithms: physical density thresholding; interactive thresholding; fuzzy c-means with 3 classes (FCM3) and 4 classes (FCM4); and k-means. The segmentation algorithms were evaluated in 2 stages: first, an approach based on the assumption that the breast composition should be the same in both prone and supine position; and second, comparison of segmentation with tissue outlines from 3 experts using the Dice similarity coefficient (DSC). Breast datasets were grouped into nonsparse and sparse fibroglandular tissue distributions according to expert assessment and used to assess the accuracy of the segmentation methods and the agreement between experts. Results: Prone and supine breast composition analysis showed differences between the methods. Validation against expert outlines found significant differences (P<.001) between FCM3 and FCM4. Fuzzy c-means with 3 classes generated segmentation results (mean DSC = 0.70) closest to the experts' outlines. There was good agreement (mean DSC = 0.85) among experts for breast tissue outlining. Segmentation accuracy and expert agreement was significantly higher (P<.005) in the nonsparse group than in the sparse group. Conclusions: The FCM3 gave the most accurate segmentation of breast tissues on CT data and could therefore be used in adaptive radiation therapy-based on tissue modeling. Breast tissue

  14. Coronary calcium scoring with MDCT: The radiation dose to the breast and the effectiveness of bismuth breast shield

    International Nuclear Information System (INIS)

    Yilmaz, Mehmet Halit; Yasar, Dogan; Albayram, Sait; Adaletli, Ibrahim; Ozer, Harun; Ozbayrak, Mustafa; Mihmanli, Ismail; Akman, Canan

    2007-01-01

    Objective: The purpose of our study was to determine the breast radiation dose during coronary calcium scoring with multidetector computerized tomography (MDCT). We also evaluated the degree of dose reduction by using a bismuth breast shield when performing coronary calcium scoring with MDCT. Materials and methods: The dose reduction achievable by shielding the adult (35 years or older) female breasts was studied in 25 women who underwent coronary calcium scoring with MDCT. All examinations were performed with a 16-MDCT scanner. To compare the shielded versus unshielded breast dose, the examinations were performed with (right breast) and without (left breast) breast shielding in all patients. With this technique the superficial breast doses were calculated. To determine the average glandular breast radiation dose, we imaged an anthropomorphic dosimetric phantom into which calibrated dosimeters were placed to measure the dose to the breast. The phantom was imaged using the same protocol. Radiation doses to the breasts with and without the breast shielding were measured and compared using the Student's t-test. Results: The mean radiation doses with and without the breast shield were 5.71 ± 1.1 mGy versus 9.08 ± 1.5 mGy, respectively. The breast shield provided a 37.12% decrease in radiation dose to the breast with shielding. The difference between the dose received by the breasts with and without bismuth shielding was significant, with a p-value of less than 0.001. Conclusion: The high radiation during MDCT greatly exceeds the recommended doses and should not be underestimated. Bismuth in plane shielding for coronary calcium scoring with MDCT decreased the radiation dose to the breast. We recommend routine use of breast shields in female patients undergoing calcium scoring with MDCT

  15. Dynamics of globular molecules: moisture effect on the Rayleigh scattering spectrum of the Moessbauer radiation

    International Nuclear Information System (INIS)

    Chesskaya, T.Yu.

    1998-01-01

    The Rayleigh scattering spectrum of the Moessbauer radiation is plotted on the model simulating globular macromolecules. The modeling results are compared with experimental data on the spectra of the Rayleigh scattering of the Moessbauer radiation for various moisture content and hydratation dependence of the elastic scattering portion

  16. Radiation therapy for breast cancer: Literature review

    International Nuclear Information System (INIS)

    Balaji, Karunakaran; Subramanian, Balaji; Yadav, Poonam; Anu Radha, Chandrasekaran; Ramasubramanian, Velayudham

    2016-01-01

    Concave shape with variable size target volume makes treatment planning for the breast/chest wall a challenge. Conventional techniques used for the breast/chest wall cancer treatment provided better sparing of organs at risk (OARs), with poor conformity and uniformity to the target volume. Advanced technologies such as intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) improve the target coverage at the cost of higher low dose volumes to OARs. Novel hybrid techniques present promising results in breast/chest wall irradiation in terms of target coverage as well as OARs sparing. Several published data compared these technologies for the benefit of the breast/chest wall with or without nodal volumes. The aim of this article is to review relevant data and identify the scope for further research in developing optimal treatment plan for breast/chest wall cancer treatment.

  17. Radiation therapy for breast cancer: Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, Karunakaran, E-mail: karthik.balaji85@gmail.com [Department of Radiation Oncology, Global Hospitals, Chennai (India); School of Advanced Sciences, VIT University, Vellore (India); Subramanian, Balaji [Department of Radiation Oncology, Global Hospitals, Chennai (India); Yadav, Poonam [Department of Medical Physics and Human Oncology, University of Wisconsin-Madison, WI and Aspirus UW Cancer Center, Wisconsin Rapids, WI (United States); Anu Radha, Chandrasekaran; Ramasubramanian, Velayudham [School of Advanced Sciences, VIT University, Vellore (India)

    2016-10-01

    Concave shape with variable size target volume makes treatment planning for the breast/chest wall a challenge. Conventional techniques used for the breast/chest wall cancer treatment provided better sparing of organs at risk (OARs), with poor conformity and uniformity to the target volume. Advanced technologies such as intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) improve the target coverage at the cost of higher low dose volumes to OARs. Novel hybrid techniques present promising results in breast/chest wall irradiation in terms of target coverage as well as OARs sparing. Several published data compared these technologies for the benefit of the breast/chest wall with or without nodal volumes. The aim of this article is to review relevant data and identify the scope for further research in developing optimal treatment plan for breast/chest wall cancer treatment.

  18. Coherent scattering X-ray imaging at the Brazilian National Synchrotron Laboratory: Preliminary breast images

    Energy Technology Data Exchange (ETDEWEB)

    Castro, C.R.F. [Nuclear Instrumentation Laboratory-COPPE/UFRJ, P.O. Box 68509, Rio de Janeiro 21945-970 (Brazil); Barroso, R.C. [Physics Institute-University of Rio de Janeiro State, Rio de Janeiro 20559-900 (Brazil)]. E-mail: cely@uerij.br; Oliveira, L.F. de [Physics Institute-University of Rio de Janeiro State, Rio de Janeiro 20559-900 (Brazil); Lopes, R.T. [Nuclear Instrumentation Laboratory-COPPE/UFRJ, P.O. Box 68509, Rio de Janeiro 21945-970 (Brazil)

    2005-08-11

    The angular distribution of coherent scatter (low-momentum transfer) carries information about atomic structures, resulting in a pattern, which can be used to reconstruct a series of images. Coherent-scatter computed tomography is a novel imaging method developed to produce cross-sectional images based on the X-ray diffraction properties of an object. A different approach to coherent X-ray imaging is possible by fixing the detector at a given scatter angle {theta}, which produces an interference peak and then, carried out a tomography in the standard way. The cross-sectional images obtained allow determining the spatial dependence of coherent scatter cross-section of selected volume elements of inhomogeneous, extend objects for a single predetermined value of {theta} of interest, leading to a simplification of the data processing and the complexity of the apparatus. This work presents preliminary coherent scattering images carried out at the X-ray Diffraction beamline of the National Synchrotron Light Laboratory in Campinas, Brazil. The specimens were excised human breast tissues fixed in formaline. No frozen procedure was used in order to minimize preferred orientation during sample preparation. About 1mm thick slices cut from each of the fresh samples were mounted in frames without windows and placed on a translator to allow acquisition of scattering spectra. Cylinders containing healthy and cancerous (infiltrating ductal carcinoma) breast tissues were imagined at the characteristic angle for adipose tissue. Transmission and coherent scatter images are compared.

  19. Nursing interventions for radiation dermatitis during breast radiotherapy

    International Nuclear Information System (INIS)

    Goto, Shiho; Nagai, Yuko

    2015-01-01

    Radiation dermatitis occurs in 95% of the women undergoing radiation therapy (RT) for breast cancer. Radiation dermatitis is one of the common acute side effects of RT and includes erythema, dry desquamation, and moist desquamation. Radiation dermatitis may cause physical distress, such as pain and itchiness, and influence individual's quality of life as well. Nurses are to reduce the distress and improve quality of life by managing the symptoms and enhancing patient's self-care ability. This article describes the supportive care for radiation dermatitis from nurse's point of view. (author)

  20. Simulating Space Radiation-Induced Breast Tumor Incidence Using Automata.

    Science.gov (United States)

    Heuskin, A C; Osseiran, A I; Tang, J; Costes, S V

    2016-07-01

    Estimating cancer risk from space radiation has been an ongoing challenge for decades primarily because most of the reported epidemiological data on radiation-induced risks are derived from studies of atomic bomb survivors who were exposed to an acute dose of gamma rays instead of chronic high-LET cosmic radiation. In this study, we introduce a formalism using cellular automata to model the long-term effects of ionizing radiation in human breast for different radiation qualities. We first validated and tuned parameters for an automata-based two-stage clonal expansion model simulating the age dependence of spontaneous breast cancer incidence in an unexposed U.S. We then tested the impact of radiation perturbation in the model by modifying parameters to reflect both targeted and nontargeted radiation effects. Targeted effects (TE) reflect the immediate impact of radiation on a cell's DNA with classic end points being gene mutations and cell death. They are well known and are directly derived from experimental data. In contrast, nontargeted effects (NTE) are persistent and affect both damaged and undamaged cells, are nonlinear with dose and are not well characterized in the literature. In this study, we introduced TE in our model and compared predictions against epidemiologic data of the atomic bomb survivor cohort. TE alone are not sufficient for inducing enough cancer. NTE independent of dose and lasting ∼100 days postirradiation need to be added to accurately predict dose dependence of breast cancer induced by gamma rays. Finally, by integrating experimental relative biological effectiveness (RBE) for TE and keeping NTE (i.e., radiation-induced genomic instability) constant with dose and LET, the model predicts that RBE for breast cancer induced by cosmic radiation would be maximum at 220 keV/μm. This approach lays the groundwork for further investigation into the impact of chronic low-dose exposure, inter-individual variation and more complex space radiation

  1. Inverse scattering and refraction corrected reflection for breast cancer imaging

    Science.gov (United States)

    Wiskin, J.; Borup, D.; Johnson, S.; Berggren, M.; Robinson, D.; Smith, J.; Chen, J.; Parisky, Y.; Klock, John

    2010-03-01

    Reflection ultrasound (US) has been utilized as an adjunct imaging modality for over 30 years. TechniScan, Inc. has developed unique, transmission and concomitant reflection algorithms which are used to reconstruct images from data gathered during a tomographic breast scanning process called Warm Bath Ultrasound (WBU™). The transmission algorithm yields high resolution, 3D, attenuation and speed of sound (SOS) images. The reflection algorithm is based on canonical ray tracing utilizing refraction correction via the SOS and attenuation reconstructions. The refraction correction reflection algorithm allows 360 degree compounding resulting in the reflection image. The requisite data are collected when scanning the entire breast in a 33° C water bath, on average in 8 minutes. This presentation explains how the data are collected and processed by the 3D transmission and reflection imaging mode algorithms. The processing is carried out using two NVIDIA® Tesla™ GPU processors, accessing data on a 4-TeraByte RAID. The WBU™ images are displayed in a DICOM viewer that allows registration of all three modalities. Several representative cases are presented to demonstrate potential diagnostic capability including: a cyst, fibroadenoma, and a carcinoma. WBU™ images (SOS, attenuation, and reflection modalities) are shown along with their respective mammograms and standard ultrasound images. In addition, anatomical studies are shown comparing WBU™ images and MRI images of a cadaver breast. This innovative technology is designed to provide additional tools in the armamentarium for diagnosis of breast disease.

  2. Application of small-angle X-ray scattering for differentiation among breast tumors

    International Nuclear Information System (INIS)

    Changizi, V.; Kheradmand, A. Arab; Oghabian, M.A.

    2008-01-01

    Small-angle X-ray scattering (SAXS) is an X-ray diffraction-based technique where a narrow collimated beam of X-rays is focused onto a sample and the scattered X-rays recorded by a detector. The pattern of the scattered X-rays carries information on the molecular structure of the material. As breast cancer is the most widespread cancer in women and differentiation among its tumors is important, this project compared the results of coherent X-ray scattering measurements obtained from benign and malignant breast tissues. The energy-dispersive method with a setup including X-ray tube, primary collimator, sample holder, secondary collimator and high-purity germanium (HpGe) detector was used. One hundred thirty-one breast-tissue samples, including normal, fibrocystic changes and carcinoma, were studied at the 6 deg scattering angle. Diffraction profiles (corrected scattered intensity versus momentum transfer) of normal, fibrocystic changes and carcinoma were obtained. These profiles showed a few peak positions for adipose (1.15 ± 0.06 nm -1 ), mixed normal (1.15 ± 0.06 nm -1 and 1.4 ± 0.04 nm -1 ), fibrocystic changes (1.46 ± 0.05 nm -1 and 1.74 ± 0.04 nm -1 ) and carcinoma (1.55 ± 0.04 nm -1 , 1.73 ± 0.06 nm -1 , 1.85 ± 0.05 nm -1 ). We were able to differentiate between normal, fibrocystic changes (benign) and carcinoma (malignant) breast tissues by SAXS. However, we were unable to differentiate between different types of carcinoma. (author)

  3. Application of small-angle X-ray scattering for differentiation among breast tumors

    Directory of Open Access Journals (Sweden)

    Changizi V

    2008-01-01

    Full Text Available Small-angle X-ray scattering (SAXS is an X-ray diffraction-based technique where a narrow collimated beam of X-rays is focused onto a sample and the scattered X-rays recorded by a detector. The pattern of the scattered X-rays carries information on the molecular structure of the material. As breast cancer is the most widespread cancer in women and differentiation among its tumors is important, this project compared the results of coherent X-ray scattering measurements obtained from benign and malignant breast tissues. The energy-dispersive method with a setup including X-ray tube, primary collimator, sample holder, secondary collimator and high-purity germanium (HpGe detector was used. One hundred thirty-one breast-tissue samples, including normal, fibrocystic changes and carcinoma, were studied at the 6° scattering angle. Diffraction profiles (corrected scattered intensity versus momentum transfer of normal, fibrocystic changes and carcinoma were obtained. These profiles showed a few peak positions for adipose (1.15 ± 0.06 nm -1 , mixed normal (1.15 ± 0.06 nm -1 and 1.4 ± 0.04 nm -1 , fibrocystic changes (1.46 ± 0.05 nm -1 and 1.74 ± 0.04 nm -1 and carcinoma (1.55 ± 0.04 nm -1 , 1.73 ± 0.06 nm -1 , 1.85 ± 0.05 nm -1 . We were able to differentiate between normal, fibrocystic changes (benign and carcinoma (malignant breast tissues by SAXS. However, we were unable to differentiate between different types of carcinoma.

  4. Scattering influence in mammographic image

    International Nuclear Information System (INIS)

    Poletti, Martin Eduardo; Almeida, Adelaide de

    1996-01-01

    The quantification of mammographic images affected by scattered radiation is studied. The average glandular dose as a function of kVp and breast thickness for breast composition 50/50% is also evaluated. The results show that the contrast decreases with increasing of kVp and breast thickness, and the average glandular dose increase with increasing breast thickness and decreases with increasing kVp

  5. X-ray scattering for the characterization of lyophilized breast tissue samples

    International Nuclear Information System (INIS)

    Elshemey, Wael M.; Mohamed, Fayrouz S.; Khater, Ibrahim M.

    2013-01-01

    This work investigates the possibility of characterizing breast cancer by measuring the X-ray scattering profiles of lyophilized excised breast tissue samples. Since X-ray scattering from water-rich tissue is dominated by scattering from water, the removal of water by lyophilization would enhance the characterization process. In the present study, X-ray scattering profiles of 22 normal, 22 malignant and 10 benign breast tissue samples are measured. The cut-offs of scatter diagrams, sensitivity, specificity and diagnostic accuracy of three characterization parameters (full width at half maximum (FWHM) for the peak at 1.1 nm −1 , area under curve (AUC), and ratio of 1st to 2nd scattering peak intensities (I 1 /I 2 %)) are calculated and compared to the data from non-lyophilized samples. Results show increased sensitivity (up to 100%) of the present data on lyophilized breast tissue samples compared to previously reported data for non-lyophilized samples while the specificity (up to 95.4%), diagnostic accuracy (up to 95.4%) and receiver operating characteristic (ROC) curve values (up to 0.9979) for both sets of data are comparable. The present study shows significant differences between normal samples and each of malignant and benign samples. Only subtle differences exist between malignant and benign lyophilized breast tissue samples where FWHM=0.7±0.1 and 0.8±0.3, AUC=1.3±0.2 and 1.4±0.2 and I 1 /I 2 %=44.9±11.0 and 52.4±7.6 for malignant and benign samples respectively. - Highlights: • X-ray scattering profiles of breast tissue samples are acquired. • Three X-ray profile characterization parameters are calculated. • The cut-offs, sensitivity, specificity and diagnostic accuracy are calculated. • They are compared to the data from non-lyophilized samples. • Results show increased sensitivity in case of lyophilized samples

  6. Interpolation methods for creating a scatter radiation exposure map

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Elicardo A. de S., E-mail: elicardo.goncalves@ifrj.edu.br [Instituto Federal do Rio de Janeiro (IFRJ), Paracambi, RJ (Brazil); Gomes, Celio S.; Lopes, Ricardo T. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Oliveira, Luis F. de; Anjos, Marcelino J. dos; Oliveira, Davi F. [Universidade do Estado do Rio de Janeiro (UFRJ), RJ (Brazil). Instituto de Física

    2017-07-01

    A well know way for best comprehension of radiation scattering during a radiography is to map exposure over the space around the source and sample. This map is done measuring exposure in points regularly spaced, it means, measurement will be placed in localization chosen by increasing a regular steps from a starting point, along the x, y and z axes or even radial and angular coordinates. However, it is not always possible to maintain the accuracy of the steps throughout the entire space, or there will be regions of difficult access where the regularity of the steps will be impaired. This work intended to use some interpolation techniques that work with irregular steps, and to compare their results and their limits. It was firstly done angular coordinates, and tested in lack of some points. Later, in the same data was performed the Delaunay tessellation interpolation ir order to compare. Computational and graphic treatments was done with the GNU OCTAVE software and its image-processing package. Real data was acquired from a bunker where a 6 MeV betatron can be used to produce radiation scattering. (author)

  7. Interpolation methods for creating a scatter radiation exposure map

    International Nuclear Information System (INIS)

    Gonçalves, Elicardo A. de S.; Gomes, Celio S.; Lopes, Ricardo T.; Oliveira, Luis F. de; Anjos, Marcelino J. dos; Oliveira, Davi F.

    2017-01-01

    A well know way for best comprehension of radiation scattering during a radiography is to map exposure over the space around the source and sample. This map is done measuring exposure in points regularly spaced, it means, measurement will be placed in localization chosen by increasing a regular steps from a starting point, along the x, y and z axes or even radial and angular coordinates. However, it is not always possible to maintain the accuracy of the steps throughout the entire space, or there will be regions of difficult access where the regularity of the steps will be impaired. This work intended to use some interpolation techniques that work with irregular steps, and to compare their results and their limits. It was firstly done angular coordinates, and tested in lack of some points. Later, in the same data was performed the Delaunay tessellation interpolation ir order to compare. Computational and graphic treatments was done with the GNU OCTAVE software and its image-processing package. Real data was acquired from a bunker where a 6 MeV betatron can be used to produce radiation scattering. (author)

  8. New method for imaging epicardial motion with scattered radiation

    International Nuclear Information System (INIS)

    Tilley, D.G.

    1976-01-01

    A new method for monitoring cardiac motion is described which employs the secondary radiation emerging from the thorax during fluoroscopic x-ray examination of the heart. The motion of selected points on the heart's epicardial surface can be investigated by detecting the intensity variations of radiation scattered in the local vicinity of the heart-lung border. Also discussed are the radiation detectors and signal processing electronics used to produce a voltage analog depicting the periodic displacements of the heart surface. Digital data processing methods are described which are used to accomplish a transformation from a time scale for representing surface motion, to a frequency scale that is better suited for the quantitative analysis of the heart's myocardial dynamics. The dynamic radiographic technique is compared to other methods such as electrocardiography, phonocardiography, radarkymography, and echocardiography; which are also used to sense the dynamic state of the heart. A three-dimensional Monte Carlo computer code is used to investigate the transport of x-radiation in the canine thorax. The Monte Carlo computer studies are used to explore the capabilities and limitations of the dynamic radiograph as it is used to sense motions of the canine heart. Animal studies were conducted with the dynamic radiograph to determine the reproducibility of the examination procedure. Canine case studies are reported showing the effects of increased myocardial contractility resulting from intervention with these inotropic agents

  9. Modern Radiation Therapy and Cardiac Outcomes in Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Boero, Isabel J.; Paravati, Anthony J.; Triplett, Daniel P.; Hwang, Lindsay; Matsuno, Rayna K.; Gillespie, Erin F.; Yashar, Catheryn M.; Moiseenko, Vitali; Einck, John P.; Mell, Loren K. [Department of Radiation Medicine and Applied Sciences, Moores Cancer Center, University of California, San Diego, La Jolla, California (United States); Parikh, Sahil A. [University Hospitals Case Medical Center, Harrington Heart and Vascular Institute, and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Murphy, James D., E-mail: j2murphy@ucsd.edu [Department of Radiation Medicine and Applied Sciences, Moores Cancer Center, University of California, San Diego, La Jolla, California (United States)

    2016-03-15

    Purpose: Adjuvant radiation therapy, which has proven benefit against breast cancer, has historically been associated with an increased incidence of ischemic heart disease. Modern techniques have reduced this risk, but a detailed evaluation has not recently been conducted. The present study evaluated the effect of current radiation practices on ischemia-related cardiac events and procedures in a population-based study of older women with nonmetastatic breast cancer. Methods and Materials: A total of 29,102 patients diagnosed from 2000 to 2009 were identified from the Surveillance, Epidemiology, and End Results–Medicare database. Medicare claims were used to identify the radiation therapy and cardiac outcomes. Competing risk models were used to assess the effect of radiation on these outcomes. Results: Patients with left-sided breast cancer had a small increase in their risk of percutaneous coronary intervention (PCI) after radiation therapy—the 10-year cumulative incidence for these patients was 5.5% (95% confidence interval [CI] 4.9%-6.2%) and 4.5% (95% CI 4.0%-5.0%) for right-sided patients. This risk was limited to women with previous cardiac disease. For patients who underwent PCI, those with left-sided breast cancer had a significantly increased risk of cardiac mortality with a subdistribution hazard ratio of 2.02 (95% CI 1.23-3.34). No other outcome, including cardiac mortality for the entire cohort, showed a significant relationship with tumor laterality. Conclusions: For women with a history of cardiac disease, those with left-sided breast cancer who underwent radiation therapy had increased rates of PCI and a survival decrement if treated with PCI. The results of the present study could help cardiologists and radiation oncologists better stratify patients who need more aggressive cardioprotective techniques.

  10. Modern Radiation Therapy and Cardiac Outcomes in Breast Cancer

    International Nuclear Information System (INIS)

    Boero, Isabel J.; Paravati, Anthony J.; Triplett, Daniel P.; Hwang, Lindsay; Matsuno, Rayna K.; Gillespie, Erin F.; Yashar, Catheryn M.; Moiseenko, Vitali; Einck, John P.; Mell, Loren K.; Parikh, Sahil A.; Murphy, James D.

    2016-01-01

    Purpose: Adjuvant radiation therapy, which has proven benefit against breast cancer, has historically been associated with an increased incidence of ischemic heart disease. Modern techniques have reduced this risk, but a detailed evaluation has not recently been conducted. The present study evaluated the effect of current radiation practices on ischemia-related cardiac events and procedures in a population-based study of older women with nonmetastatic breast cancer. Methods and Materials: A total of 29,102 patients diagnosed from 2000 to 2009 were identified from the Surveillance, Epidemiology, and End Results–Medicare database. Medicare claims were used to identify the radiation therapy and cardiac outcomes. Competing risk models were used to assess the effect of radiation on these outcomes. Results: Patients with left-sided breast cancer had a small increase in their risk of percutaneous coronary intervention (PCI) after radiation therapy—the 10-year cumulative incidence for these patients was 5.5% (95% confidence interval [CI] 4.9%-6.2%) and 4.5% (95% CI 4.0%-5.0%) for right-sided patients. This risk was limited to women with previous cardiac disease. For patients who underwent PCI, those with left-sided breast cancer had a significantly increased risk of cardiac mortality with a subdistribution hazard ratio of 2.02 (95% CI 1.23-3.34). No other outcome, including cardiac mortality for the entire cohort, showed a significant relationship with tumor laterality. Conclusions: For women with a history of cardiac disease, those with left-sided breast cancer who underwent radiation therapy had increased rates of PCI and a survival decrement if treated with PCI. The results of the present study could help cardiologists and radiation oncologists better stratify patients who need more aggressive cardioprotective techniques.

  11. Rayleigh to Compton ratio scatter tomography applied to breast cancer diagnosis: A preliminary computational study

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2014-01-01

    In the present work, a tomographic technique based on Rayleigh to Compton scattering ratio (R/C) was studied using computational simulation in order to assess its application to breast cancer diagnosis. In this preliminary study, some parameters that affect the image quality were evaluated, such as: (i) energy beam, (ii) size and glandularity of the breast, and (iii) statistical count noise. The results showed that the R/C contrast increases with increasing photon energy and decreases with increasing glandularity of the sample. The statistical noise showed to be a significant parameter, although the quality of the obtained images was acceptable for a considerable range of noise level. The preliminary results suggest that the R/C tomographic technique has a potential of being applied as a complementary tool in the breast cancer diagnostic. - Highlights: ► A tomographic technique based on Rayleigh to Compton scattering ratio is proposed in order to study breast tissues. ► The Rayleigh to Compton scattering ratio technique is compared with conventional transmission technique. ► The influence of experimental parameters (energy, sample, detection system) is studied

  12. The role of a prone setup in breast radiation therapy.

    Science.gov (United States)

    Huppert, Nelly; Jozsef, Gabor; Dewyngaert, Keith; Formenti, Silvia Chiara

    2011-01-01

    Most patients undergoing breast conservation therapy receive radiotherapy in the supine position. Historically, prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. With the advent of CT planning, the prone technique has become both feasible and reproducible. It was shown to be advantageous not only for women with larger breasts but in most patients since it consistently reduces, if not eliminates, the inclusion of heart and lung within the field. The prone setup has been accepted as the best localizing position for both MRI and stereotactic biopsy, but its adoption has been delayed in radiotherapy. New technological advances including image-modulated radiation therapy and image-guided radiation therapy have made possible the exploration of accelerated fractionation schemes with a concomitant boost to the tumor bed in the prone position, along with better imaging and verification of reproducibility of patient setup. This review describes some of the available techniques for prone breast radiotherapy and the available experience in their application. The NYU prone breast radiotherapy approach is discussed, including a summary of the results from several prospective trials.

  13. The role of a prone setup in breast radiation therapy

    Directory of Open Access Journals (Sweden)

    Nelly eHuppert

    2011-10-01

    Full Text Available Most patients undergoing breast conservation therapy (BCT receive radiotherapy in the supine position. Historically, prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. With the advent of CT planning, the prone technique has become both feasible and reproducible. It was shown to be advantageous not only for women with larger breasts but in most patients since it consistently reduces, if not eliminates, the inclusion of heart and lung within the field. The prone setup has been accepted as the best localizing position for both MRI and stereotactic biopsy, but its adoption has been delayed in radiotherapy. New technological advances including image-modulated radiation therapy (IMRT and image-guided radiation therapy (IGRT have made possible the exploration of accelerated fractionation schemes with a concomitant boost to the tumor bed in the prone position, along with better imaging and verification of reproducibility of patient setup. This review describes some of the available techniques for prone breast radiotherapy and the available experience in their application. The NYU prone breast radiotherapy approach is discussed, including a summary of the results from several prospective trials.

  14. The Role of a Prone Setup in Breast Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Huppert, Nelly; Jozsef, Gabor; DeWyngaert, Keith; Formenti, Silvia Chiara, E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York University Langone Medical Center, New York, NY (United States)

    2011-10-11

    Most patients undergoing breast conservation therapy receive radiotherapy in the supine position. Historically, prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. With the advent of CT planning, the prone technique has become both feasible and reproducible. It was shown to be advantageous not only for women with larger breasts but in most patients since it consistently reduces, if not eliminates, the inclusion of heart and lung within the field. The prone setup has been accepted as the best localizing position for both MRI and stereotactic biopsy, but its adoption has been delayed in radiotherapy. New technological advances including image-modulated radiation therapy and image-guided radiation therapy have made possible the exploration of accelerated fractionation schemes with a concomitant boost to the tumor bed in the prone position, along with better imaging and verification of reproducibility of patient setup. This review describes some of the available techniques for prone breast radiotherapy and the available experience in their application. The NYU prone breast radiotherapy approach is discussed, including a summary of the results from several prospective trials.

  15. Changes in skin microcirculation during radiation therapy for breast cancer.

    Science.gov (United States)

    Tesselaar, Erik; Flejmer, Anna M; Farnebo, Simon; Dasu, Alexandru

    2017-08-01

    The majority of breast cancer patients who receive radiation treatment are affected by acute radiation-induced skin changes. The assessment of these changes is usually done by subjective methods, which complicates the comparison between different treatments or patient groups. This study investigates the feasibility of new robust methods for monitoring skin microcirculation to objectively assess and quantify acute skin reactions during radiation treatment. Laser Doppler flowmetry, laser speckle contrast imaging, and polarized light spectroscopy imaging were used to measure radiation-induced changes in microvascular perfusion and red blood cell concentration (RBC) in the skin of 15 patients undergoing adjuvant radiation therapy for breast cancer. Measurements were made before treatment, once a week during treatment, and directly after the last fraction. In the treated breast, perfusion and RBC concentration were increased after 1-5 fractions (2.66-13.3 Gy) compared to baseline. The largest effects were seen in the areola and the medial area. No changes in perfusion and RBC concentration were seen in the untreated breast. In contrast, Radiation Therapy Oncology Group (RTOG) scores were increased only after 2 weeks of treatment, which demonstrates the potential of the proposed methods for early assessment of skin changes. Also, there was a moderate to good correlation between the perfusion (r = 0.52) and RBC concentration (r = 0.59) and the RTOG score given a week later. We conclude that radiation-induced microvascular changes in the skin can be objectively measured using novel camera-based techniques before visual changes in the skin are apparent. Objective measurement of microvascular changes in the skin may be valuable in the comparison of skin reactions between different radiation treatments and possibly in predicting acute skin effects at an earlier stage.

  16. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing

    International Nuclear Information System (INIS)

    Ramamurthy, Senthil; D’Orsi, Carl J; Sechopoulos, Ioannis

    2016-01-01

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360° with a perforated tungsten plate in the path of the x-ray beam. To make patient testing feasible, a wirelessly controlled electronic positioner for the tungsten plate was designed and added to a breast CT system. Other improvements to the algorithm were implemented, including automated exclusion of non-valid primary estimate points and the use of a different approximation method to estimate the full scatter signal. To evaluate the effectiveness of the algorithm, evaluation of the resulting image quality was performed with a breast phantom and with nine patient images. The improvements in the algorithm resulted in the avoidance of introduction of artifacts, especially at the object borders, which was an issue in the previous implementation in some cases. Both contrast, in terms of signal difference and signal difference-to-noise ratio were improved with the proposed method, as opposed to with the correction algorithm incorporated in the system, which does not recover contrast. Patient image evaluation also showed enhanced contrast, better cupping correction, and more consistent voxel values for the different tissues. The algorithm also reduces artifacts present in reconstructions of non-regularly shaped breasts. With the implemented hardware and software improvements, the proposed method can be reliably used during patient breast CT imaging, resulting in improvement of image quality, no introduction of artifacts, and in some cases reduction of artifacts already present. The impact of the algorithm on actual clinical performance for detection, diagnosis and other clinical tasks in breast imaging remains to be evaluated. (paper)

  17. Optimization of Adjuvant Radiation in Breast Conservation Therapy: Can We Minimize without Compromise?

    International Nuclear Information System (INIS)

    Edwards-Bennett, S.M.; Correa, C.R.; Harris, E.E.

    2011-01-01

    Adjuvant breast radiation therapy after breast conservation surgery is recommended as it yields significant reduction in the risk of local recurrence, and confers a potential overall survival benefit. Although the standard breast radiation regimen has historically been delivered over 57 weeks; more novel, shorter courses of breast radiation are currently being employed, offering the advantage of more convenience and less time-commitment. Herein, we review the recent literature substantiating these abbreviated radiation treatment approaches and the methods of delivery thereof. In addition, we discuss imaged guided techniques currently being utilized to further refine the delivery of adjuvant breast radiation therapy

  18. Light scattering reviews 7 radiative transfer and optical properties of atmosphere and underlying surface

    CERN Document Server

    Kokhanovsky, Alexander A

    2014-01-01

    This book describes modern advances in radiative transfer and light scattering. Coverage includes fast radiative transfer techniques, use of polarization in remote sensing and recent developments in remote sensing of snow properties from space observations.

  19. Scattering of point particles by black holes: Gravitational radiation

    Science.gov (United States)

    Hopper, Seth; Cardoso, Vitor

    2018-02-01

    Gravitational waves can teach us not only about sources and the environment where they were generated, but also about the gravitational interaction itself. Here we study the features of gravitational radiation produced during the scattering of a pointlike mass by a black hole. Our results are exact (to numerical error) at any order in a velocity expansion, and are compared against various approximations. At large impact parameter and relatively small velocities our results agree to within percent level with various post-Newtonian and weak-field results. Further, we find good agreement with scaling predictions in the weak-field/high-energy regime. Lastly, we achieve striking agreement with zero-frequency estimates.

  20. The implications of breast cancer molecular phenotype for radiation oncology

    Directory of Open Access Journals (Sweden)

    Shirin eSioshansi

    2011-06-01

    Full Text Available The identification of distinct molecular subtypes of breast cancer has advanced the understanding and treatment of breast cancer by providing insight into prognosis, patterns of recurrence and effectiveness of therapy. The prognostic significance of molecular phenotype with regard to distant recurrences and overall survival are well established in the literature and has been readily incorporated into systemic therapy management decisions. However, despite the accumulating data suggesting similar prognostic significance for locoregional recurrence, integration of molecular phenotype into local management decision making has lagged. Although there are some conflicting reports, collectively the literature supports a low risk of local recurrence in the hormone receptor positive luminal subtypes compared to hormone receptor negative subtypes (triple negative and HER2-enriched. The development of targeted therapies, such as trastuzumab for the treatment of HER2-enriched subtype, has been shown to mitigate the increased risk of local recurrence. Unfortunately, no such remedy exists to address the increased risk of local recurrence for patients with triple negative tumors, making it a clinical challenge for radiation oncologists. In this review we discuss the correlation between molecular subtype and local recurrence following either breast conservation therapy or mastectomy. We also explore the possible mechanisms for increased local recurrence in triple negative breast cancer and radiotherapeutic implications for this population, such as the safety of breast conservation, consideration of dose escalation and the appropriateness of accelerated partial breast irradiation.

  1. The Implications of Breast Cancer Molecular Phenotype for Radiation Oncology

    Energy Technology Data Exchange (ETDEWEB)

    Sioshansi, Shirin [Department of Radiation Oncology, Tufts Medical Center, Tufts University School of Medicine, Boston, MA (United States); Department of Radiation Oncology, Rhode Island Hospital, Warren Alpert School of Medicine at Brown University, Providence, RI (United States); Huber, Kathryn E. [Department of Radiation Oncology, Tufts Medical Center, Tufts University School of Medicine, Boston, MA (United States); Wazer, David E., E-mail: dwazer@tuftsmedicalcenter.org [Department of Radiation Oncology, Tufts Medical Center, Tufts University School of Medicine, Boston, MA (United States); Department of Radiation Oncology, Rhode Island Hospital, Warren Alpert School of Medicine at Brown University, Providence, RI (United States)

    2011-06-28

    The identification of distinct molecular subtypes of breast cancer has advanced the understanding and treatment of breast cancer by providing insight into prognosis, patterns of recurrence, and effectiveness of therapy. The prognostic significance of molecular phenotype with regard to distant recurrences and overall survival are well established in the literature and has been readily incorporated into systemic therapy management decisions. However, despite the accumulating data suggesting similar prognostic significance for locoregional recurrence, integration of molecular phenotype into local management decision making has lagged. Although there are some conflicting reports, collectively the literature supports a low risk of local recurrence (LR) in the hormone receptor (HR) positive luminal subtypes compared to HR negative subtypes [triple negative (TN) and HER2-enriched]. The development of targeted therapies, such as trastuzumab for the treatment of HER2-enriched subtype, has been shown to mitigate the increased risk of LR. Unfortunately, no such remedy exists to address the increased risk of LR for patients with TN tumors, making it a clinical challenge for radiation oncologists. In this review we discuss the correlation between molecular subtype and LR following either breast conservation therapy or mastectomy. We also explore the possible mechanisms for increased LR in TN breast cancer and radiotherapeutic implications for this population, such as the safety of breast conservation, consideration of dose escalation, and the appropriateness of accelerated partial breast irradiation.

  2. The Implications of Breast Cancer Molecular Phenotype for Radiation Oncology

    International Nuclear Information System (INIS)

    Sioshansi, Shirin; Huber, Kathryn E.; Wazer, David E.

    2011-01-01

    The identification of distinct molecular subtypes of breast cancer has advanced the understanding and treatment of breast cancer by providing insight into prognosis, patterns of recurrence, and effectiveness of therapy. The prognostic significance of molecular phenotype with regard to distant recurrences and overall survival are well established in the literature and has been readily incorporated into systemic therapy management decisions. However, despite the accumulating data suggesting similar prognostic significance for locoregional recurrence, integration of molecular phenotype into local management decision making has lagged. Although there are some conflicting reports, collectively the literature supports a low risk of local recurrence (LR) in the hormone receptor (HR) positive luminal subtypes compared to HR negative subtypes [triple negative (TN) and HER2-enriched]. The development of targeted therapies, such as trastuzumab for the treatment of HER2-enriched subtype, has been shown to mitigate the increased risk of LR. Unfortunately, no such remedy exists to address the increased risk of LR for patients with TN tumors, making it a clinical challenge for radiation oncologists. In this review we discuss the correlation between molecular subtype and LR following either breast conservation therapy or mastectomy. We also explore the possible mechanisms for increased LR in TN breast cancer and radiotherapeutic implications for this population, such as the safety of breast conservation, consideration of dose escalation, and the appropriateness of accelerated partial breast irradiation.

  3. ATM, radiation, and the risk of second primary breast cancer.

    Science.gov (United States)

    Bernstein, Jonine L; Concannon, Patrick

    2017-10-01

    It was first suggested more than 40 years ago that heterozygous carriers for the human autosomal recessive disorder Ataxia-Telangiectasia (A-T) might also be at increased risk for cancer. Subsequent studies have identified the responsible gene, Ataxia-Telangiectasia Mutated (ATM), characterized genetic variation at this locus in A-T and a variety of different cancers, and described the functions of the ATM protein with regard to cellular DNA damage responses. However, an overall model of how ATM contributes to cancer risk, and in particular, the role of DNA damage in this process, remains lacking. This review considers these questions in the context of contralateral breast cancer (CBC). Heterozygous carriers of loss of function mutations in ATM that are A-T causing, are at increased risk of breast cancer. However, examination of a range of genetic variants, both rare and common, across multiple cancers, suggests that ATM may have additional effects on cancer risk that are allele-dependent. In the case of CBC, selected common alleles at ATM are associated with a reduced incidence of CBC, while other rare and predicted deleterious variants may act jointly with radiation exposure to increase risk. Further studies that characterize germline and somatic ATM mutations in breast cancer and relate the detected genetic changes to functional outcomes, particularly with regard to radiation responses, are needed to gain a complete picture of the complex relationship between ATM, radiation and breast cancer.

  4. [Gamma scattering in condensed matter with high intensity Moessbauer radiation

    International Nuclear Information System (INIS)

    1992-01-01

    This report discusses: quasielastic scattering studies on glycerol; gamma-ray scattering from alkali halides; lattice dynamics in metals; Moessbauer neutron scattering, x-ray diffraction, and macroscopic studies of high T c superconductors containing tungsten; NiAl scattering studies; and atomic interference factors and nuclear Casimir effect

  5. Measuring main-ion temperatures in ASDEX upgrade using scattering of ECRH radiation

    DEFF Research Database (Denmark)

    Pedersen, Morten Stejner; Nielsen, Stefan Kragh; Jacobsen, Asger Schou

    2016-01-01

    We demonstrate that collective Thomson scattering of millimeter wave electron cyclotron resonance heating radiation can be used for measurements of the main-ion temperature in the ASDEX Upgrade tokamak.......We demonstrate that collective Thomson scattering of millimeter wave electron cyclotron resonance heating radiation can be used for measurements of the main-ion temperature in the ASDEX Upgrade tokamak....

  6. Exclusive radical radiation therapy in breast carcinoma

    International Nuclear Information System (INIS)

    Dubois, J.B.; Salomon, A.; Gary-Bobo, J.; Pourquier, H.; Pujol, H.

    1991-01-01

    The results are presented of 186 breast cancer patients treated initially for locoregional disease by radiotherapy alone, combining cobalt therapy with external electron beam or interstitial iridium implants. According to the TNM classification, the patients were distributed as follows: 3 T 1 N 0 , 2 T 1 N 1 , 33 T 2 N 0 , 36 T 2 N 1 , 16 T 3 N 0 , 26 T 3 N 1 , 6 T 3 N 2 , 14 T 4 N 0 , 29 T 4 N 1 , 9 T 4 N 2 and 12 T 4 N 3 . The 5- and 10-year survival rates (52.7 and 36.5 per cent respectively, for all patients) were directly correlated with the size and location of the breast tumor, and the extent of lymph node involvement. Locoregional recurrence was observed in 39.8 per cent of the cases, metastases alone in 26.8 per cent, and a combination of local recurrence and distant metastasis in 14.5 per cent of the cases. The local recurrences and metastases were directly correlated with the extent of locoregional involvement. Late complications and sequelae were mostly minor and occurred in less than 25 per cent of the cases; severe sequelae in no more than 2 per cent. They depended on the initial tumor volume and the tumor dose. The results, along with those in the literature, indicate that radiotherapy administered alone is a valid therapeutic option in breast cancer. (author). 23 refs.; 5 tabs

  7. Radiation therapy as definitive treatment of breast cancer

    International Nuclear Information System (INIS)

    Findlay, P.A.

    1988-01-01

    Like surgery, radiation therapy is a local treatment modality, and also like surgery, the objective of therapy is to eradicate all cancer in the treated area, ensuring no recurrence. In addition, this objective should be achieved with maintenance of a cosmetically intact breast. If these two goals can be attained simultaneously, the ultimate result should be a substantial reduction in the physical and psychologic morbidity of treatment and an improvement in the patients's quality of life. It is to be hoped that by reducing women's fear of potentially disfiguring surgery, they will be encouraged to seek medical attention for breast cancer at an earlier, and hence potentially more curable, stage of the disease

  8. Multiple scattering of polarized light: comparison of Maxwell theory and radiative transfer theory.

    Science.gov (United States)

    Voit, Florian; Hohmann, Ansgar; Schäfer, Jan; Kienle, Alwin

    2012-04-01

    For many research areas in biomedical optics, information about scattering of polarized light in turbid media is of increasing importance. Scattering simulations within this field are mainly performed on the basis of radiative transfer theory. In this study a polarization sensitive Monte Carlo solution of radiative transfer theory is compared to exact Maxwell solutions for all elements of the scattering Müller matrix. Different scatterer volume concentrations are modeled as a multitude of monodisperse nonabsorbing spheres randomly positioned in a cubic simulation volume which is irradiated with monochromatic incident light. For all Müller matrix elements effects due to dependent scattering and multiple scattering are analysed. The results are in overall good agreement between the two methods with deviations related to dependent scattering being prominent for high volume concentrations and high scattering angles.

  9. TH-AB-209-10: Breast Cancer Identification Through X-Ray Coherent Scatter Spectral Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kapadia, A; Morris, R; Albanese, K; Spencer, J; McCall, S; Greenberg, J [Duke University, Durham, NC (United States)

    2016-06-15

    Purpose: We have previously described the development and testing of a coherent-scatter spectral imaging system for identification of cancer. Our prior evaluations were performed using either tissue surrogate phantoms or formalin-fixed tissue obtained from pathology. Here we present the first results from a scatter imaging study using fresh breast tumor tissues obtained through surgical excision. Methods: A coherent-scatter imaging system was built using a clinical X-ray tube, photon counting detectors, and custom-designed coded-apertures. System performance was characterized using calibration phantoms of biological materials. Fresh breast tumors were obtained from patients undergoing mastectomy and lumpectomy surgeries for breast cancer. Each specimen was vacuum-sealed, scanned using the scatter imaging system, and then sent to pathology for histological workup. Scatter images were generated separately for each tissue specimen and analyzed to identify voxels containing malignant tissue. The images were compared against histological analysis (H&E + pathologist identification of tumors) to assess the match between scatter-based and histological diagnosis. Results: In all specimens scanned, the scatter images showed the location of cancerous regions within the specimen. The detection and classification was performed through automated spectral matching without the need for manual intervention. The scatter spectra corresponding to cancer tissue were found to be in agreement with those reported in literature. Inter-patient variability was found to be within limits reported in literature. The scatter images showed agreement with pathologist-identified regions of cancer. Spatial resolution for this configuration of the scanner was determined to be 2–3 mm, and the total scan time for each specimen was under 15 minutes. Conclusion: This work demonstrates the utility of coherent scatter imaging in identifying cancer based on the scatter properties of the tissue. It

  10. Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

    International Nuclear Information System (INIS)

    Osa, Etin-Osa O.; DeWyngaert, Keith; Roses, Daniel; Speyer, James; Guth, Amber; Axelrod, Deborah; Fenton Kerimian, Maria; Goldberg, Judith D.; Formenti, Silvia C.

    2014-01-01

    Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm 3 , mean 19.65 cm 3 . In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm 3 , mean 1.59 cm 3 . There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and fractionation

  11. Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

    Energy Technology Data Exchange (ETDEWEB)

    Osa, Etin-Osa O.; DeWyngaert, Keith [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Roses, Daniel [Department of Surgery, New York University School of Medicine, New York, New York (United States); Speyer, James [Department of Medical Oncology, New York University School of Medicine, New York, New York (United States); Guth, Amber; Axelrod, Deborah [Department of Surgery, New York University School of Medicine, New York, New York (United States); Fenton Kerimian, Maria [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Goldberg, Judith D. [Department of Population Health, New York University School of Medicine, New York, New York (United States); Formenti, Silvia C., E-mail: Silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States)

    2014-07-15

    Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm{sup 3}, mean 19.65 cm{sup 3}. In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm{sup 3}, mean 1.59 cm{sup 3}. There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and

  12. Near-infrared spectral tomography integrated with digital breast tomosynthesis: Effects of tissue scattering on optical data acquisition design

    Energy Technology Data Exchange (ETDEWEB)

    Michaelsen, Kelly; Krishnaswamy, Venkat; Pogue, Brian W.; Poplack, Steven P.; Paulsen, Keith D. [Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755 (United States); Department of Diagnostic Radiology, Dartmouth Medical School, Lebanon, New Hampshire 03756 (United States); Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755 and Department of Diagnostic Radiology, Dartmouth Medical School, Lebanon, New Hampshire 03756 (United States)

    2012-07-15

    Purpose: Design optimization and phantom validation of an integrated digital breast tomosynthesis (DBT) and near-infrared spectral tomography (NIRST) system targeting improvement in sensitivity and specificity of breast cancer detection is presented. Factors affecting instrumentation design include minimization of cost, complexity, and examination time while maintaining high fidelity NIRST measurements with sufficient information to recover accurate optical property maps. Methods: Reconstructed DBT slices from eight patients with abnormal mammograms provided anatomical information for the NIRST simulations. A limited frequency domain (FD) and extensive continuous wave (CW) NIRST system was modeled. The FD components provided tissue scattering estimations used in the reconstruction of the CW data. Scattering estimates were perturbed to study the effects on hemoglobin recovery. Breast mimicking agar phantoms with inclusions were imaged using the combined DBT/NIRST system for comparison with simulation results. Results: Patient simulations derived from DBT images show successful reconstruction of both normal and malignant lesions in the breast. They also demonstrate the importance of accurately quantifying tissue scattering. Specifically, 20% errors in optical scattering resulted in 22.6% or 35.1% error in quantification of total hemoglobin concentrations, depending on whether scattering was over- or underestimated, respectively. Limited frequency-domain optical signal sampling provided two regions scattering estimates (for fat and fibroglandular tissues) that led to hemoglobin concentrations that reduced the error in the tumor region by 31% relative to when a single estimate of optical scattering was used throughout the breast volume of interest. Acquiring frequency-domain data with six wavelengths instead of three did not significantly improve the hemoglobin concentration estimates. Simulation results were confirmed through experiments in two-region breast mimicking

  13. Near-infrared spectral tomography integrated with digital breast tomosynthesis: Effects of tissue scattering on optical data acquisition design

    International Nuclear Information System (INIS)

    Michaelsen, Kelly; Krishnaswamy, Venkat; Pogue, Brian W.; Poplack, Steven P.; Paulsen, Keith D.

    2012-01-01

    Purpose: Design optimization and phantom validation of an integrated digital breast tomosynthesis (DBT) and near-infrared spectral tomography (NIRST) system targeting improvement in sensitivity and specificity of breast cancer detection is presented. Factors affecting instrumentation design include minimization of cost, complexity, and examination time while maintaining high fidelity NIRST measurements with sufficient information to recover accurate optical property maps. Methods: Reconstructed DBT slices from eight patients with abnormal mammograms provided anatomical information for the NIRST simulations. A limited frequency domain (FD) and extensive continuous wave (CW) NIRST system was modeled. The FD components provided tissue scattering estimations used in the reconstruction of the CW data. Scattering estimates were perturbed to study the effects on hemoglobin recovery. Breast mimicking agar phantoms with inclusions were imaged using the combined DBT/NIRST system for comparison with simulation results. Results: Patient simulations derived from DBT images show successful reconstruction of both normal and malignant lesions in the breast. They also demonstrate the importance of accurately quantifying tissue scattering. Specifically, 20% errors in optical scattering resulted in 22.6% or 35.1% error in quantification of total hemoglobin concentrations, depending on whether scattering was over- or underestimated, respectively. Limited frequency-domain optical signal sampling provided two regions scattering estimates (for fat and fibroglandular tissues) that led to hemoglobin concentrations that reduced the error in the tumor region by 31% relative to when a single estimate of optical scattering was used throughout the breast volume of interest. Acquiring frequency-domain data with six wavelengths instead of three did not significantly improve the hemoglobin concentration estimates. Simulation results were confirmed through experiments in two-region breast mimicking

  14. Occupational radiation exposure to low doses of ionizing radiation and female breast cancer

    International Nuclear Information System (INIS)

    Adelina, P.; Bliznakov, V.; Bairacova, A.

    2003-01-01

    The aim of this study is to examine the relationship between past occupational radiation exposure to low doses of ionizing radiation and cases of diagnosed and registered breast cancer [probability of causation - PC] among Bulgarian women who have used different ionizing radiation sources during their working experience. The National Institute of Health (NIH) in US has developed a method for estimating the probability of causation (PC) between past occupational radiation exposure to low doses of ionizing radiation and cases of diagnosed cancer. We have used this method. A group of 27 women with diagnosed breast cancer has been studied. 11 of them are former workers in NPP - 'Kozloduy', and 16 are from other sites using different sources of ionizing radiation. Analysis was performed for 14 women, for whom full personal data were available. The individual radiation dose for each of them is below 1/10 of the annual dose limit, and the highest cumulative dose for a period of 14 years of occupational exposure is 50,21 mSv. The probability of causation (PC) values in all analyzed cases are below 1%, which confirms the extremely low probability of causation (PC) between past occupational radiation exposure to low doses of ionizing radiation and occurring cases of breast cancer. (orig.)

  15. A software-based x-ray scatter correction method for breast tomosynthesis

    International Nuclear Information System (INIS)

    Jia Feng, Steve Si; Sechopoulos, Ioannis

    2011-01-01

    Purpose: To develop a software-based scatter correction method for digital breast tomosynthesis (DBT) imaging and investigate its impact on the image quality of tomosynthesis reconstructions of both phantoms and patients. Methods: A Monte Carlo (MC) simulation of x-ray scatter, with geometry matching that of the cranio-caudal (CC) view of a DBT clinical prototype, was developed using the Geant4 toolkit and used to generate maps of the scatter-to-primary ratio (SPR) of a number of homogeneous standard-shaped breasts of varying sizes. Dimension-matched SPR maps were then deformed and registered to DBT acquisition projections, allowing for the estimation of the primary x-ray signal acquired by the imaging system. Noise filtering of the estimated projections was then performed to reduce the impact of the quantum noise of the x-ray scatter. Three dimensional (3D) reconstruction was then performed using the maximum likelihood-expectation maximization (MLEM) method. This process was tested on acquisitions of a heterogeneous 50/50 adipose/glandular tomosynthesis phantom with embedded masses, fibers, and microcalcifications and on acquisitions of patients. The image quality of the reconstructions of the scatter-corrected and uncorrected projections was analyzed by studying the signal-difference-to-noise ratio (SDNR), the integral of the signal in each mass lesion (integrated mass signal, IMS), and the modulation transfer function (MTF). Results: The reconstructions of the scatter-corrected projections demonstrated superior image quality. The SDNR of masses embedded in a 5 cm thick tomosynthesis phantom improved 60%-66%, while the SDNR of the smallest mass in an 8 cm thick phantom improved by 59% (p < 0.01). The IMS of the masses in the 5 cm thick phantom also improved by 15%-29%, while the IMS of the masses in the 8 cm thick phantom improved by 26%-62% (p < 0.01). Some embedded microcalcifications in the tomosynthesis phantoms were visible only in the scatter

  16. Use of implicit Monte Carlo radiation transport with hydrodynamics and compton scattering

    International Nuclear Information System (INIS)

    Fleck, J.A. Jr.

    1971-03-01

    It is shown that the combination of implicit radiation transport and hydrodynamics, Compton scattering, and any other energy transport can be simply carried out by a ''splitting'' procedure. Contributions to material energy exchange can be reckoned separately for hydrodynamics, radiation transport without scattering, Compton scattering, plus any other possible energy exchange mechanism. The radiation transport phase of the calculation would be implicit, but the hydrodynamics and Compton portions would not, leading to possible time step controls. The time step restrictions which occur on radiation transfer due to large Planck mean absorption cross-sections would not occur

  17. Scatter radiation from chest radiographs: is there a risk to infants in a typical NICU?

    International Nuclear Information System (INIS)

    Trinh, Angela M.; Schoenfeld, Alan H.; Levin, Terry L.

    2010-01-01

    To evaluate the dose of scatter radiation to infants in a NICU in order to determine the minimal safe distance between isolettes. Dose secondary to scattered radiation from an acrylic phantom exposed to vertical and horizontal beam exposures at 56 kVp was measured at 93 cm and 125 cm from the center of the phantom. This corresponds to 2 and 3 ft between standard isolettes, respectively. For horizontal exposures, the dosimeter was placed directly behind a CR plate and scatter dose at 90-degrees and 135-degrees from the incident beam was also measured. Exposures were obtained at 160 mAs and the results were extrapolated to correspond to 2.5 mAs. Four measurements were taken at each point and averaged. At 125 cm and 93 cm there was minimal scatter compared to daily natural background radiation dose (8.493 μGy). Greatest scatter dose obtained from a horizontal beam exposure at 135 from the incident beam was still far below background radiation. Scatter radiation dose from a single exposure as well as cumulative scatter dose from numerous exposures is significantly below natural background radiation. Infants in neighboring isolettes are not at added risk from radiation scatter as long as the isolettes are separated by at least 2 ft. (orig.)

  18. Application of the equivalent radiator method for radiative corrections to the spectra of elastic electron scattering by nuclei

    Directory of Open Access Journals (Sweden)

    I. S. Timchenko

    2015-07-01

    Full Text Available For calculating the radiative tails in the spectra of inelastic electron scattering by nuclei, the approximation, namely, the equivalent radiator method (ERM, is used. However, the applicability of this method for evaluating the radiative tail from the elastic scattering peak has been little investigated, and therefore, it has become the subject of the present study for the case of light nuclei. As a result, spectral regions were found, where a significant discrepancy between the ERM calculation and the exact-formula calculation was observed. A link was established between this phenomenon and the diffraction minimum of the squared form-factor of the nuclear ground state. Varieties of calculations were carried out for different kinematics of electron scattering by nuclei. The analysis of the calculation results has shown the conditions, at which the equivalent radiator method can be applied for adequately evaluating the radiative tail of the elastic scattering peak.

  19. Radiation dermatitis and pneumonitis following breast conserving therapy

    International Nuclear Information System (INIS)

    Yoden, Eisaku; Hiratsuka, Junichi; Imajo, Yoshinari

    2000-01-01

    We investigated the frequency, degree and risk factors of radiation-induced dermatitis and pneumonitis in 255 patients receiving breast conserving therapy between April 1987 and April 1998. The majority of the patients underwent a wide excision or quadrantectomy with a level I, II axillary dissection, followed by radiotherapy consisting of 50 Gy/25 Fr/5 weeks to the preserved breast with a 4 MV beam by tangentially opposed portals using the half-field technique. Eleven patients received an additional 10 Gy/5 Fr of electron therapy to the tumor bed. Most of the patients developed radiation dermatitis which was limited to reddening or dry desquamation, with the exception of 14 patients with a localized moist reaction. The skin reaction was transient in all patients and improved with conservative treatments. Radiation pneumonitis appeared on chest X-rays in 30 patients, with a slight appearance in 21 and patchy appearance in 9. Three patients presented with persistent symptoms requiring medication. They were treated with steroids, resulting in complete resolution of the symptoms. A large volume of the chest wall within the irradiation field and a large area of irradiated skin were the risk factors of radiation dermatitis. The volume of irradiated lung significantly correlated with the frequency and degree of radiation pneumonitis. It was preferable that the maximum thickness of the involved lung should not exceed 3 cm. Complicated disease, adjuvant therapy and boost irradiation had no impact on the radiation dermatitis or pneumonitis. (author)

  20. Reduction of the scattered radiation during X-ray examination with screen-film systems

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, V N; Stavitsky, R V [Moscow Research Inst. for Roentgenology and Radiology, Moscow (Russian Federation); Oshomkov, Yu V [Mosroentgen, Moscow Region (Russian Federation)

    1993-01-01

    In diagnostic radiography, during X-ray examination, photons scattered in the patient's body are detected by the intensifying screen and decrease the image contrast. A conventional way to avoid this image degradation is to attenuate the scattered radiation by an antiscatter grid placed between the patient's body and the screen. A grid selectivity effect originates from the greater attenuation of scattered as opposed to primary radiation. Previous authors calculated the primary and scattered radiation transmission factor of photons with initial energy 30-120 keV for a number of typical grids. The primary radiation transmission factor varied from 0.34 to 0.67 and the secondary radiation factor was equal from 0.03 to 0.13. This effect results in a contrast improvement from 2 to 6, but the patient exposure increases up to a factor of 10. In this work we studied the possibility of improving the image contrast by attenuating the scattered radiation by a secondary filter placed between the patient's body and the screen and made of an appropriate material. A selectivity effect due to the secondary filter arises from two circumstances. First, tilting incidence of the scattered radiation results in the path inside the filter being greater than the primary one. Second, the average energy of the scattered radiation is less than the primary and, hence, the attenuation coefficient is greater. (author).

  1. Change in Seroma Volume During Whole-Breast Radiation Therapy

    International Nuclear Information System (INIS)

    Sharma, Rajiv; Spierer, Marnee; Mutyala, Subhakar; Thawani, Nitika; Cohen, Hillel W.; Hong, Linda; Garg, Madhur K.; Kalnicki, Shalom

    2009-01-01

    Purpose: After breast-conserving surgery, a seroma often forms in the surgical cavity. If not drained, it may affect the volume of tumor bed requiring a boost after whole-breast radiation therapy (WBRT). Our objective was to evaluate the change in seroma volume that occurs during WBRT, before boost planning. Methods and Materials: A retrospective review was performed of women receiving breast-conserving therapy with evidence of seroma at the time of WBRT planning. Computed tomography (CT) simulation was performed before WBRT and before the tumor bed boost. All patients received either a hypofractionated (42.4 Gy/16 fraction + 9.6 Gy/4 fraction boost) or standard fractionated (50.4 Gy/28 fraction + 10 Gy/5 fraction boost) regimen. Seroma volumes were contoured and compared on CT at the time of WBRT simulation and tumor bed boost planning. Results: Twenty-four patients with evidence of seroma were identified and all patients received WBRT without drainage of the seroma. Mean seroma volume before WBRT and at boost planning were significantly different at 65.7 cm 3 (SD, 50.5 cm 3 ) and 35.6 cm 3 (SD, 24.8 cm 3 ), respectively (p < 0.001). Mean and median reduction in seroma volume during radiation were 39.6% (SD, 23.8%) and 46.2% (range, 10.7-76.7%), respectively. Fractionation schedule was not correlated with change in seroma volume. Length of time from surgery to start of radiation therapy showed an inverse correlation with change in seroma volume (Pearson correlation r = -0.53, p < 0.01). Conclusions: The volume of seroma changes significantly during WBRT. Consequently, the accuracy of breast boost planning is likely affected, as is the volume of normal breast tissue irradiated. CT-based boost planning before boost irradiation is suggested to ensure appropriate coverage.

  2. The simple analytical method for scattered radiation calculation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In realization of radiation protection measures for medical staff present during diagnostic procedures, the necessary condition is knowledge of the space - energy distributions of the scattered radiation from the patient. In this paper, the simple calculation procedure for the scattered radiation field of the actual diagnostic energies is presented. Starting from the single Compton scattering model and using the justified transformations the final equations in elementary form are derived. For numerical calculations the computer code ANGIO was created. The calculated results were confirmed by detailed dosimetric measurements of the scattered field around patient (the water phantom) in SSDL in the Institute of nuclear sciences `Vinca`, Belgrade. These results are good base for assessment of irradiation. The main irradiation source for the physician and the other members of the medical team is the back scattered radiation from patient - albedo. (author). 3 figs., 3 refs.

  3. Radiation exposure and breast cancer: lessons from Chernobyl.

    Science.gov (United States)

    Ogrodnik, Aleksandra; Hudon, Tyler W; Nadkarni, Prakash M; Chandawarkar, Rajiv Y

    2013-04-01

    The lessons learned from the Chernobyl disaster have become increasingly important after the second anniversary of the Fukushima, Japan nuclear accident. Historically, data from the Chernobyl reactor accident 27 years ago demonstrated a strong correlation with thyroid cancer, but data on the radiation effects of Chernobyl on breast cancer incidence have remained inconclusive. We reviewed the published literature on the effects of the Chernobyl disaster on breast cancer incidence, using Medline and Scopus from the time of the accident to December of 2010. Our findings indicate limited data and statistical flaws. Other confounding factors, such as discrepancies in data collection, make interpretation of the results from the published literature difficult. Re-analyzing the data reveals that the incidence of breast cancer in Chernobyl-disaster-exposed women could be higher than previously thought. We have learned little of the consequences of radiation exposure at Chernobyl except for its effects on thyroid cancer incidence. Marking the 27th year after the Chernobyl event, this report sheds light on a specific, crucial and understudied aspect of the results of radiation from a gruesome nuclear power plant disaster.

  4. Analysis of radiation-induced angiosarcoma of the breast.

    Science.gov (United States)

    Zemanova, M; Rauova, K; Boljesikova, E; Machalekova, K; Krajcovicova, I; Lehotska, V; Mikulova, M; Svec, J

    2014-01-01

    Breast angiosarcoma may occur de novo, or as a complication of radiation therapy, or chronic lymphedema secondary to axillary lymph node dissection for mammary carcinoma. Both primary and secondary angiosarcomas may present with bruise like skin discoloration, which may delay the diagnosis. Imaging findings are nonspecific. In case of high-grade tumours, MRI may be used effectively to determine lesion extent by showing rapid enhancement, nevertheless earliest possible diagnostics is crucial therefore any symptoms of angiosarcoma have to be carefully analysed. The case analysed here reports on results of 44-year old premenopausal woman who was treated for a T1N1M0 invasive ductal carcinoma. After a biopsy diagnosis of carcinoma, the patient underwent quadrantectomy with axillary lymph node dissection. She received partial 4 cycles of chemotherapy with adriamycin and cyclophosphamide, followed by radiation treatment. Thereafter, a standard postoperative radiotherapy was applied at our institution four months after chemotherapy (TD 46 Gy in 23 fractions followed by a 10 Gy electron boost to the tumour bed). Adjuvant chemotherapy was finished six months after operation, followed by tamoxifen. Follow up: no further complications were detected during regular check-ups. However, 12-years later, patient reported significant changes at breast region which was exposed to radiation during treatment of original tumour. In this article, we describe the clinical presentation, imaging and pathological findings of secondary angiosarcoma of the breast after radiotherapy (Fig. 2, Ref. 26).

  5. Thyroid and hypophysial function in radiation therapy of breast cancer

    International Nuclear Information System (INIS)

    Yakimova, T.P.; Lozinskaya, I.N.

    1984-01-01

    In breast cancer a decrease in triiodothyronine concentration was revealed with the normal level of thyroxine that may be associated with the disturbed peripharal metabolism into triiodothyronine. The lowering of thyroid functional activity is noted during radiation therapy of patients at menopause. Administration of thyroidin during radiation therapy to elderly patients with the 3 stage of the disease compensated for hormone deficiency producing a sparing effect on the thyroid, and influenced the therapeutic results favorably. A high level of the somatotropic hormone was observed in patients, of the reproductive age and at menopause, the level of insulin was increased in all the patients

  6. A study of low Q2 radiative Bhabha scattering

    International Nuclear Information System (INIS)

    Karlen, D.A.

    1988-03-01

    This thesis presents a study of electron-positron scattering, via nearly real photon exchange, where in the process one or more high energy photons are produced. The motivations behind the work are twofold. Firstly, the study is a sensitive test of the theory of electron-photon interactions, quantum electrodynamics. A deviation from the theory could indicate that the electron is a composite particle. Secondly, a thorough understanding of this process is necessary for experiments to be done in the near future at the Stanford Linear Collider and the LEP facility at CERN. Calculations for the process to third and fourth order in pertubation theory are described. Methods for simulating the process by a Monte Carlo event generator are given. Results from the calculations are compared to data from the Mark II experiment at the PEP storage ring. The ratio of measured to calculated cross sections are 0.993 /+-/ 0.017 /+-/ 0.015 and 0.99 /+-/ 0.16 /+-/ 0.08 for final states with one and two observed photons respectively, where the first errors are statistical and the second systematic. The excellent agreement verifies the calculations of the fourth order radiative correction. No evidence for electron substructure is observed

  7. Reversible brachial plexopathy following primary radiation therapy for breast cancer

    International Nuclear Information System (INIS)

    Salner, A.L.; Botnick, L.E.; Herzog, A.G.; Goldstein, M.A.; Harris, J.R.; Levene, M.B.; Hellman, S.

    1981-01-01

    Reversible brachial plexopathy has occurred in very low incidence in patients with breast carcinoma treated definitively with radiation therapy. Of 565 patients treated between January 1968 and December 1979 with moderate doses of supervoltage radiation therapy (average axillary dose of 5000 rad in 5 weeks), eight patients (1.4%) developed the characteristic symptoms at a median time of 4.5 months after radiation therapy. This syndrome consists of paresthesias in all patients, with weakness and pain less commonly seen. The symptom complex differs from other previously described brachial plexus syndromes, including paralytic brachial neuritis, radiation-induced injury, and carcinoma. A possible relationship to adjuvant chemotherapy exists, though the etiology is not well-understood. The cases described demonstrate temporal clustering. Resolution is always seen

  8. Determination of the scattered radiation at the Neutron Calibration Laboratory of IPEN, SP, Brazil

    International Nuclear Information System (INIS)

    Alvarenga, Tallyson; Valeriano, Caio C.S.; Caldas, Linda V.E.; Federico, Claudio A.

    2016-01-01

    With the increased use of techniques using neutron radiation, there has been a considerable growth in the number of detectors for this kind of radiation. A neutron calibration laboratory with neutron radiation ("2"4"1AmBe) was designed. In practical situations of this type of laboratory, one of the main problems is related to the knowledge of scattered radiation. In order to evaluate this scattered radiation, simulations were carried out without the presence of structural elements and with the complete room. Fourteen measuring points were evaluated in different directions at various distances. (author)

  9. Efficacy of breast shielding during CT of the head

    International Nuclear Information System (INIS)

    Brnic, Z.; Hebrang, A.; Anic, P.

    2002-01-01

    The aims of this study were to investigate in vivo the levels of breast exposure to scatter radiation in head CT examination and the dependence of breast exposure upon body constitution. We tried to estimate the efficacy of external lead shielding as a mean of breast dose reduction. We wanted to estimate how much radiation reaches the organ from outside, in comparison to radiation load due to internal scatter

  10. Compton scattering and electron-atom scattering in an elliptically polarized laser field of relativistic radiation power

    International Nuclear Information System (INIS)

    Panek, P.; Kaminski, J.Z.; Ehlotzky, F.

    2003-01-01

    Presently available laser sources can yield powers for which the ponderomotive energy of an electron U p can be equal to or even larger than the rest energy mc 2 of an electron. Therefore it has become of interest to consider fundamental radiation-induced or assisted processes in such powerful laser fields. In the present work we consider laser-induced Compton scattering and laser-assisted electron atom scattering in such fields, assuming that the laser beam has arbitrary elliptic polarization. We investigate in detail the angular and polarisation dependence of the differential cross-sections of the two laser-induced or laser-assisted nonlinear processes as a function of the order N of absorbed or emitted laser photons ω. The present work is a generalization of our previous analysis of Compton scattering and electron-atom scattering in a linearly polarized laser field. (authors)

  11. Diagnosis of breast cancer using elastic-scattering spectroscopy: preliminary clinical results

    Science.gov (United States)

    Bigio, Irving J.; Brown, Stephen G.; Briggs, Gavin M.; Kelley, Christine; Lakhani, Sunil; Pickard, David; Ripley, Paul M.; Rose, Ian; Saunders, Christobel

    2000-04-01

    We report on the first stages of a clinical study designed to test elastic-scattering spectroscopy, medicated by fiberoptic probes, for three specific clinical applications in breast-tissue diagnosis: (1) a transdermal-needle (interstitial) measurement for instant diagnosis with minimal invasiveness similar to fine-needle aspiration but with sensitivity to a larger tissue volume, (2) a hand-held diagnostic probe for use in assessing tumor/resection margins during open surgery, and (3) use of the same probe for real-time assessment of the `sentinel' node during surgery to determine the presence or absence of tumor (metastatic). Preliminary results from in vivo measurements on 31 women are encouraging. Optical spectra were measured on 72 histology sites in breast tissue, and 54 histology sites in sentinel nodes. Two different artificial intelligence methods of spectral classification were studied. Artificial neural networks yielded sensitivities of 69% and 58%, and specificities of 85% and 93%, for breast tissue and sentinel nodes, respectively. Hierarchical cluster analysis yielded sensitivities of 67% and 91%, and specificities of 79% and 77%, for breast tissue and sentinel nodes, respectively. These values are expected to improve as the data sets continue to grow and more sophisticated data preprocessing is employed. The study will enroll up to 400 patients over the next two years.

  12. Determination of the gamma radiation scattering with geometry changes in the system

    International Nuclear Information System (INIS)

    Albuquerque, M. da P.P.; Xavier, M.; Caldas, L.V.E.

    1988-07-01

    Three different experimental systems were used for the determination of the radiation scattering due to the walls, ceiling and floor of the Calibration Laboratory. The radiation detection was made with a portable ionization chamber Victoreen model Panoramic 470. The measurements were taken with and without the use of a lead shield block between the detector and the radioactive source. The results showed that the scattering contribution increased about 80%, as the distance between detector and source was varied from 1,0 to 2,0 m. Therefore the scattering contribution determination is very important for the establishment of the standard radiation fields for instruments calibration. (author) [pt

  13. Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

    Directory of Open Access Journals (Sweden)

    Afshin Akbarzadeh

    2009-06-01

    Full Text Available Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter correction techniques. Empirical methods based on blocking the primary photons in a small region are not able to extract scatter in all elements of the detector array while the scatter profile is required for a scatter correction procedure. In this study, we measured scatter profiles in 64 slice CT scanners using a new experimental measurement. Material and Methods: To measure the scatter profile, a lead block array was inserted under the collimator and the phantom was exposed at the isocenter. The raw data file, which contained detector array readouts, was transferred to a PC and was read using a dedicated GUI running under MatLab 7.5. The scatter profile was extracted by interpolating the shadowed area. Results: The scatter and SPR profiles were measured. Increasing the tube voltage from 80 to 140 kVp resulted in an 80% fall off in SPR for a water phantom (d=210 mm and 86% for a polypropylene phantom (d = 350 mm. Increasing the air gap to 20.9 cm caused a 30% decrease in SPR. Conclusion: In this study, we presented a novel approach for measurement of scattered radiation distribution and SPR in a CT scanner with 64-slice capability using a lead block array. The method can also be used on other multi-slice CT scanners. The proposed technique can accurately estimate scatter profiles. It is relatively straightforward, easy to use, and can be used for any related measurement.

  14. Radiation pneumonitis: a complication resulting from combined radiation and chemotherapy for early breast cancer

    International Nuclear Information System (INIS)

    Gez, E.; Sulkes, A.; Isacson, R.; Catane, R.; Weshler, Z.

    1985-01-01

    Described is a patient with early breast carcinoma who developed clinical radiation pneumonitis during primary radiation therapy and concomitant chemotherapy that included prednisone. This syndrome developed three days following abrupt steroid withdrawal. Retrieval of steroids brought complete resolution of the clinical and radiological findings. Although this syndrome is rare, it is recommended that steroid therapy in a patient previously irradiated to the chest be avoided

  15. Patterns of dose variability in radiation prescription of breast cancer

    International Nuclear Information System (INIS)

    Das, Indra J.; Chee-Wai, Cheng; Fein, Douglas A.; Fowble, Barbara

    1995-01-01

    Objective: Radiation dose distribution varies with breast size, beam energy, beam modifiers (wedge, bolus), and beam weights. A dose variation as low as ± 5% has been observed to change outcome of the radiation treatment. Various reports suggest that radiation dose >50 Gy and dose inhomogeneity >10% have unfavorable cosmesis. It is difficult to estimate treatment outcome and compare data in various protocols due to the variability of dose prescriptions. A retrospective analysis of the pattern of dose prescription and intercomparison of various protocols is presented for the treatment of breast cancer. Materials and Methods: In this study, five prescription points were chosen to represent the commonly used protocols for breast irradiation. All these points lie on a line of height, h, of the breast apex from the posterior non-divergent beam edge at half the chest-wall separation,s . The points are located at a distance 1.5 cm, chest wall-lung interface (2-3 cm), (h(3)), (h(2)), and at isocenter. One hundred consecutive patients treated with intact breast irradiation following excisional biopsy were selected. For analysis, treatment planning was carried out without lung correction with a 6 MV beam for all patients, even though some of the patients were treated with high energy beams. Dose distributions were optimized with proper wedges and beam weights to provide a symmetrical dose distribution on the central axis plane. A multivariate analysis of the different parameters, s,h , dose at the hot spot, and doses at various prescription points were carried out. The patients were divided into three groups based on the chest-wall separations: small ( 22.0 cm). The dose distributions related to various prescription points used in different protocols were analyzed for three groups of the patients. Results: The magnitudes of the hot spots varied from +5% to +27% among the patient population, were directly related to s, and appeared to be independent of h. The hot spots

  16. Once-Daily Radiation Therapy for Inflammatory Breast Cancer

    International Nuclear Information System (INIS)

    Brown, Lindsay; Harmsen, William; Blanchard, Miran; Goetz, Matthew; Jakub, James; Mutter, Robert; Petersen, Ivy; Rooney, Jessica; Stauder, Michael; Yan, Elizabeth; Laack, Nadia

    2014-01-01

    Purpose: Inflammatory breast cancer (IBC) is a rare and aggressive breast cancer variant treated with multimodality therapy. A variety of approaches intended to escalate the intensity and efficacy of radiation therapy have been reported, including twice-daily radiation therapy, dose escalation, and aggressive use of bolus. Herein, we examine our outcomes for patients treated with once-daily radiation therapy with aggressive bolus utilization, focusing on treatment technique. Methods and Materials: A retrospective review of patients with nonmetastatic IBC treated from January 1, 2000, through December 31, 2010, was performed. Locoregional control (LRC), disease-free survival (DFS), overall survival (OS) and predictors thereof were assessed. Results: Fifty-two women with IBC were identified, 49 (94%) of whom were treated with neoadjuvant chemotherapy. All underwent mastectomy followed by adjuvant radiation therapy. Radiation was delivered in once-daily fractions of 1.8 to 2.25 Gy (median, 2 Gy). Patients were typically treated with daily 1-cm bolus throughout treatment, and 33 (63%) received a subsequent boost to the mastectomy scar. Five-year Kaplan Meier survival estimates for LRC, DFS, and OS were 81%, 56%, and 64%, respectively. Locoregional recurrence was associated with poorer OS (P<.001; hazard ratio [HR], 4.1). Extracapsular extension was associated with worse LRC (P=.02), DFS (P=.007), and OS (P=.002). Age greater than 50 years was associated with better DFS (P=.03). Pathologic complete response was associated with a trend toward improved LRC (P=.06). Conclusions: Once-daily radiation therapy with aggressive use of bolus for IBC results in outcomes consistent with previous reports using various intensified radiation therapy regimens. LRC remains a challenge despite modern systemic therapy. Extracapsular extension, age ≤50 years, and lack of complete response to chemotherapy appear to be associated with worse outcomes. Novel strategies are needed in IBC

  17. Radiation-associated breast tumors display a distinct gene expression profile

    DEFF Research Database (Denmark)

    Broeks, Annegien; Braaf, Linde M; Wessels, Lodewyk F A

    2010-01-01

    PURPOSE: Women who received irradiation for Hodgkin's lymphoma have a strong increased risk for developing breast cancer. Approximately 90% of the breast cancers in these patients can be attributed to their radiation treatment, rendering such series extremely useful to determine whether a common...... radiation-associated cause underlies the carcinogenic process. METHODS AND MATERIALS: In this study we used gene expression profiling technology to assess gene expression changes in radiation-associated breast tumors compared with a set of control breast tumors of women unexposed to radiation, diagnosed...... at the same age. RNA was obtained from fresh frozen tissue samples from 22 patients who developed breast cancer after Hodgkin's lymphoma (BfHL) and from 20 control breast tumors. RESULTS: Unsupervised hierarchical clustering of the profile data resulted in a clustering of the radiation-associated tumors...

  18. Radiation-Induced Breast Cancer Incidence and Mortality From Digital Mammography Screening: A Modeling Study.

    Science.gov (United States)

    Miglioretti, Diana L; Lange, Jane; van den Broek, Jeroen J; Lee, Christoph I; van Ravesteyn, Nicolien T; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J; Melnikow, Joy; de Koning, Harry J; Hubbard, Rebecca A

    2016-02-16

    Estimates of risk for radiation-induced breast cancer from mammography screening have not considered variation in dose exposure or diagnostic work-up after abnormal screening results. To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening while considering exposure from screening and diagnostic mammography and dose variation among women. 2 simulation-modeling approaches. U.S. population. Women aged 40 to 74 years. Annual or biennial digital mammography screening from age 40, 45, or 50 years until age 74 years. Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality (harms) per 100,000 women screened. Annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancer cases (95% CI, 88 to 178) leading to 16 deaths (CI, 11 to 23), relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 cases of radiation-induced breast cancer leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete examination (8% of population) were projected to have greater radiation-induced breast cancer risk (266 cancer cases and 35 deaths per 100,000 women) than other women (113 cancer cases and 15 deaths per 100,000 women). Biennial screening starting at age 50 years reduced risk for radiation-induced cancer 5-fold. Life-years lost from radiation-induced breast cancer could not be estimated. Radiation-induced breast cancer incidence and mortality from digital mammography screening are affected by dose variability from screening, resultant diagnostic work-up, initiation age, and screening frequency. Women with large breasts may have a greater risk for radiation-induced breast cancer. Agency for Healthcare Research and Quality, U.S. Preventive Services Task Force, National Cancer Institute.

  19. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    International Nuclear Information System (INIS)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee

    2009-01-01

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis

  20. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee [Keimyung University, School of Medicine, Daegu (Korea, Republic of)

    2009-08-15

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis.

  1. Delineation of Supraclavicular Target Volumes in Breast Cancer Radiation Therapy

    International Nuclear Information System (INIS)

    Brown, Lindsay C.; Diehn, Felix E.; Boughey, Judy C.; Childs, Stephanie K.; Park, Sean S.; Yan, Elizabeth S.; Petersen, Ivy A.; Mutter, Robert W.

    2015-01-01

    Purpose: To map the location of gross supraclavicular metastases in patients with breast cancer, in order to determine areas at highest risk of harboring subclinical disease. Methods and Materials: Patients with axial imaging of gross supraclavicular disease were identified from an institutional breast cancer registry. Locations of the metastatic lymph nodes were transferred onto representative axial computed tomography images of the supraclavicular region and compared with the Radiation Therapy Oncology Group (RTOG) breast cancer atlas for radiation therapy planning. Results: Sixty-two patients with 161 supraclavicular nodal metastases were eligible for study inclusion. At the time of diagnosis, 117 nodal metastases were present in 44 patients. Forty-four nodal metastases in 18 patients were detected at disease recurrence, 4 of whom had received prior radiation to the supraclavicular fossa. Of the 161 nodal metastases, 95 (59%) were within the RTOG consensus volume, 4 nodal metastases (2%) in 3 patients were marginally within the volume, and 62 nodal metastases (39%) in 30 patients were outside the volume. Supraclavicular disease outside the RTOG consensus volume was located in 3 regions: at the level of the cricoid and thyroid cartilage (superior to the RTOG volume), in the posterolateral supraclavicular fossa (posterolateral to the RTOG volume), and in the lateral low supraclavicular fossa (lateral to the RTOG volume). Only women with multiple supraclavicular metastases had nodal disease that extended superiorly to the level of the thyroid cartilage. Conclusions: For women with risk of harboring subclinical supraclavicular disease warranting the addition of supraclavicular radiation, coverage of the posterior triangle and the lateral low supraclavicular region should be considered. For women with known supraclavicular disease, extension of neck coverage superior to the cricoid cartilage may be warranted

  2. Delineation of Supraclavicular Target Volumes in Breast Cancer Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Lindsay C. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Diehn, Felix E. [Department of Radiology, Mayo Clinic, Rochester, Minnesota (United States); Boughey, Judy C. [Department of Surgery, Mayo Clinic, Rochester, Minnesota (United States); Childs, Stephanie K.; Park, Sean S.; Yan, Elizabeth S.; Petersen, Ivy A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Mutter, Robert W., E-mail: mutter.robert@mayo.edu [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States)

    2015-07-01

    Purpose: To map the location of gross supraclavicular metastases in patients with breast cancer, in order to determine areas at highest risk of harboring subclinical disease. Methods and Materials: Patients with axial imaging of gross supraclavicular disease were identified from an institutional breast cancer registry. Locations of the metastatic lymph nodes were transferred onto representative axial computed tomography images of the supraclavicular region and compared with the Radiation Therapy Oncology Group (RTOG) breast cancer atlas for radiation therapy planning. Results: Sixty-two patients with 161 supraclavicular nodal metastases were eligible for study inclusion. At the time of diagnosis, 117 nodal metastases were present in 44 patients. Forty-four nodal metastases in 18 patients were detected at disease recurrence, 4 of whom had received prior radiation to the supraclavicular fossa. Of the 161 nodal metastases, 95 (59%) were within the RTOG consensus volume, 4 nodal metastases (2%) in 3 patients were marginally within the volume, and 62 nodal metastases (39%) in 30 patients were outside the volume. Supraclavicular disease outside the RTOG consensus volume was located in 3 regions: at the level of the cricoid and thyroid cartilage (superior to the RTOG volume), in the posterolateral supraclavicular fossa (posterolateral to the RTOG volume), and in the lateral low supraclavicular fossa (lateral to the RTOG volume). Only women with multiple supraclavicular metastases had nodal disease that extended superiorly to the level of the thyroid cartilage. Conclusions: For women with risk of harboring subclinical supraclavicular disease warranting the addition of supraclavicular radiation, coverage of the posterior triangle and the lateral low supraclavicular region should be considered. For women with known supraclavicular disease, extension of neck coverage superior to the cricoid cartilage may be warranted.

  3. Anisotropic scattering in three dimensional differential approximation of radiation heat transfer

    International Nuclear Information System (INIS)

    Condiff, D.W.

    1987-01-01

    The differential approximation is extended to account for anisotropic scattering in invariant three dimensional form. A moment method using polyadic Legendre functions establishes that pressure cross sections should take precedence over extinction cross sections for treating radiation heat transfer in an absorbing, emitting, and scattering medium, and that use of these cross sections accounts for the extent of preferred forward or backwards scattering. The procedure and principle is extended to polyadic P-N approximations

  4. Hard synchrotron radiation scattering from a nonideal surface grating from multilayer X-ray mirrors

    International Nuclear Information System (INIS)

    Punegov, V.I.; Nesterets, Ya.I.; Mytnichenko, S.V.; Kovalenko, N.V.; Chernov, V.A.

    2003-01-01

    The hard synchrotron radiation scattering from a multilayer surface grating is theoretically and experimentally investigated. The numerical calculations of angular distribution of scattering intensity from X-ray mirror Ni/C are executed with use of recurrence formulae and statistical dynamical theory of diffraction. It is shown, that the essential role in formation of a diffraction pattern plays a diffuse scattering caused by structure imperfection of a multilayer grating [ru

  5. A new radiative transfer scattering phase function discretisation approach with inherent energy conservation

    CSIR Research Space (South Africa)

    Roos, TH

    2014-06-01

    Full Text Available large sphere scattering phase function distributions of interest for packed bed radiative heat transfer: the analytic distribution for a diffusely reflecting sphere (a backscattering test case) and the distribution for a transparent sphere (n = 1...

  6. Scattered radiation field in X-ray diagnostics; Polje rasejanog zracenja u rendgen dijagnostici

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, S; Boreli, F [Institute of Nuclear Sciences VINCA, Belgrade (Yugoslavia)

    1995-07-01

    In order to obtain simple analytical relation for spatial distribution of scattered X radiation around patient, the analytical procedure of simplification of starting equations is presented in this paper. (author)

  7. Velocity-space tomography of fusion plasmas by collective Thomson scattering of gyrotron radiation

    DEFF Research Database (Denmark)

    Salewski, Mirko; Jacobsen, A.S.; Jensen, Thomas

    2016-01-01

    -tonoise ratio becomes fairly low for MeV-range ions. Ions at any energy can be detected well by collective Thomson scattering of mm-wave radiation from a high-power gyrotron. We demonstrate how collective Thomson scattering can be used to measure 푓2퐷푣 in the MeV-range in reactor relevant plasmas...

  8. Characterizing the behavior of scattered radiation in multi-energy x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sossin, Artur, E-mail: artur.sossin@gmail.com [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Rebuffel, V.; Tabary, J. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Létang, J.M.; Freud, N. [Univ Lyon, INSA-Lyon, Université Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Centre Léon Bérard, CREATIS UMR 5220 U1206, F-69373 Lyon (France); Verger, L. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France)

    2017-04-01

    Scattered radiation results in various undesirable effects in medical diagnostics, non-destructive testing (NDT) and security x-ray imaging. Despite numerous studies characterizing this phenomenon and its effects, the knowledge of its behavior in the energy domain remains limited. The present study aims at summarizing some key insights on scattered radiation originating from the inspected object. In addition, various simulations and experiments with limited collimation on both simplified and realistic phantoms were conducted in order to study scatter behavior in multi-energy x-ray imaging. Results showed that the spectrum shape of the scatter component can be considered preserved in the first approximation across the image plane for various acquisition geometries and phantoms. The variations exhibited by the scatter spectrum were below 10% for most examined cases. Furthermore, the corresponding spectrum shape proved to be also relatively invariant for different experimental angular projections of one of the examined phantoms. The observed property of scattered radiation can potentially lead to the decoupling of spatial and energy scatter components, which can in turn enable speed ups in scatter simulations and reduce the complexity of scatter correction.

  9. Forward-scattered radiation from the compression paddle should be considered in glandular dose estimations

    International Nuclear Information System (INIS)

    Hemdal, B.

    2011-01-01

    From major protocols on dosimetry in mammography, there is no doubt that the incident air kerma should be evaluated without backscattered radiation to the dosemeter. However, forward-scattered radiation from the compression paddle is neglected. The aim of this work was to analyse the contribution of forward-scattered radiation for typical air kerma measurements. Measurements of forward-scatter were performed with a plane-parallel ionisation chamber on four mammography units. The forward-scatter contribution to the air kerma was 2-10 % and increased with the compression paddle thickness, but also with the half-value layer value. For incident air kerma in mammography, it can be as important to consider forward scattered as backscattered radiation. If an ionisation chamber is used, the compression paddle should be in contact with the chamber; otherwise the air kerma and absorbed dose will be underestimated. If a dosemeter based on semiconductors with much less sensitivity to scattered radiation is used, it is suggested that a forward-scatter factor (FSF) is applied. Based on the results of this work, FSF=1.06 will lead to a maximum error of ∼4 %. (authors)

  10. Results of conservative surgery and radiation therapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Osteen, R.T.; Smith, B.L. (Harvard Medical School, Boston, MA (USA))

    1990-10-01

    For stage I or II breast cancer, conservative surgery and radiation therapy are as effective as modified radical or radical mastectomy. In most cases, cosmetic considerations and the availability of therapy are the primary concerns. The extent of a surgical resection less than a mastectomy has not been a subject of a randomized trial and is controversial. It appears that removal of a quadrant of the breast for small lesions is safe but excessive. It may be possible to limit the breast resection to gross tumor removal for most patients while using wider resections for patients with an extensive intraductal component or for invasive lobular carcinoma. It also appears that excluding patients from breast conservation on the basis of positive margins on the first attempt at tumor excision may be unnecessarily restrictive. Although patients with an extensive intraductal component or invasive lobular carcinoma should have negative margins, it appears that a patient with predominantly invasive ductal carcinoma can be treated without re-excision if all gross tumor has been resected and there is no reason to suspect extensive microscopic disease. Patients with indeterminate margins should have a re-excision. Axillary dissection provides prognostic information and prevents progression of the disease within the axilla. Axillary dissections limited to level I will accurately identify a substantial number of patients who have pathologically positive but clinically negative nodes. When combined with radiation therapy to the axilla, a level I dissection results in a limited number of patients with progressive axillary disease. Patients with pathologically positive axillas and patients at particularly high risk for systemic disease because of the extent of axillary node involvement can be identified by dissections of levels I and II. 60 references.

  11. Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

    Science.gov (United States)

    Brunner, Stephen; Nett, Brian E; Tolakanahalli, Ranjini; Chen, Guang-Hong

    2011-02-21

    X-ray scatter is a significant problem in cone-beam computed tomography when thicker objects and larger cone angles are used, as scattered radiation can lead to reduced contrast and CT number inaccuracy. Advances have been made in x-ray computed tomography (CT) by incorporating a high quality prior image into the image reconstruction process. In this paper, we extend this idea to correct scatter-induced shading artifacts in cone-beam CT image-guided radiation therapy. Specifically, this paper presents a new scatter correction algorithm which uses a prior image with low scatter artifacts to reduce shading artifacts in cone-beam CT images acquired under conditions of high scatter. The proposed correction algorithm begins with an empirical hypothesis that the target image can be written as a weighted summation of a series of basis images that are generated by raising the raw cone-beam projection data to different powers, and then, reconstructing using the standard filtered backprojection algorithm. The weight for each basis image is calculated by minimizing the difference between the target image and the prior image. The performance of the scatter correction algorithm is qualitatively and quantitatively evaluated through phantom studies using a Varian 2100 EX System with an on-board imager. Results show that the proposed scatter correction algorithm using a prior image with low scatter artifacts can substantially mitigate scatter-induced shading artifacts in both full-fan and half-fan modes.

  12. Monte Carlo calculation of scattered radiation from applicators in low energy clinical electron beams

    International Nuclear Information System (INIS)

    Jabbari, N.; Hashemi-Malayeri, B.; Farajollahi, A. R.; Kazemnejad, A.

    2007-01-01

    In radiotherapy with electron beams, scattered radiation from an electron applicator influences the dose distribution in the patient. The contribution of this radiation to the patient dose is significant, even in modern accelerators. In most of radiotherapy treatment planning systems, this component is not explicitly included. In addition, the scattered radiation produced by applicators varies based on the applicator design as well as the field size and distance from the applicators. The aim of this study was to calculate the amount of scattered dose contribution from applicators. We also tried to provide an extensive set of calculated data that could be used as input or benchmark data for advanced treatment planning systems that use Monte Carlo algorithms for dose distribution calculations. Electron beams produced by a NEPTUN 10PC medical linac were modeled using the BEAMnrc system. Central axis depth dose curves of the electron beams were measured and calculated, with and without the applicators in place, for different field sizes and energies. The scattered radiation from the applicators was determined by subtracting the central axis depth dose curves obtained without the applicators from that with the applicator. The results of this study indicated that the scattered radiation from the electron applicators of the NEPTUN 10PC is significant and cannot be neglected in advanced treatment planning systems. Furthermore, our results showed that the scattered radiation depends on the field size and decreases almost linearly with depth. (author)

  13. Contralateral breast cancer risk

    International Nuclear Information System (INIS)

    Unnithan, Jaya; Macklis, Roger M.

    2001-01-01

    The use of breast-conserving treatment approaches for breast cancer has now become a standard option for early stage disease. Numerous randomized studies have shown medical equivalence when mastectomy is compared to lumpectomy followed by radiotherapy for the local management of this common problem. With an increased emphasis on patient involvement in the therapeutic decision making process, it is important to identify and quantify any unforeseen risks of the conservation approach. One concern that has been raised is the question of radiation- related contralateral breast cancer after breast radiotherapy. Although most studies do not show statistically significant evidence that patients treated with breast radiotherapy are at increased risk of developing contralateral breast cancer when compared to control groups treated with mastectomy alone, there are clear data showing the amount of scattered radiation absorbed by the contralateral breast during a routine course of breast radiotherapy is considerable (several Gy) and is therefore within the range where one might be concerned about radiogenic contralateral tumors. While radiation related risks of contralateral breast cancer appear to be small enough to be statistically insignificant for the majority of patients, there may exist a smaller subset which, for genetic or environmental reasons, is at special risk for scatter related second tumors. If such a group could be predicted, it would seem appropriate to offer either special counselling or special prevention procedures aimed at mitigating this second tumor risk. The use of genetic testing, detailed analysis of breast cancer family history, and the identification of patients who acquired their first breast cancer at a very early age may all be candidate screening procedures useful in identifying such at- risk groups. Since some risk mitigation strategies are convenient and easy to utilize, it makes sense to follow the classic 'ALARA' (as low as reasonably

  14. A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Oliver, Mike; Chen, Jeff; Wong, Eugene; Van Dyk, Jake; Perera, Francisco

    2007-01-01

    Purpose and background: Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast irradiation for their radiation conformity index, dose homogeneity index, and dose to organs at risk. Methods and materials: Small-field tangents, three-dimensional conformal radiation therapy, intensity-modulated radiation therapy and helical tomotherapy were compared for each of 15 patients (7 right, 8 left). One radiation conformity and two dose homogeneity indices were used to evaluate the dose to the target. The mean dose to organs at risk was also evaluated. Results: All proposed APBI techniques improved the conformity index significantly over whole breast tangents while maintaining dose homogeneity and without a significant increase in dose to organs at risk. Conclusion: The four-field IMRT plan produced the best dosimetric results; however this technique would require appropriate respiratory motion management. An alternative would be to use a four-field conformal technique that is less sensitive to the effects of respiratory motion

  15. Adjuvant radiation therapy versus surgery alone in operable breast cancer

    International Nuclear Information System (INIS)

    Rutqvist, L.E.; Pettersson, D.; Johansson, H.

    1993-01-01

    This paper presents long-term results from a randomized trial of pre- or postoperative megavoltage radiation therapy versus surgery alone in pre- and postmenopausal women with operable breast cancer. Treatment outcome after relapse among patients who developed loco-regional recurrences was also analyzed. A total of 960 patients were included in the trial. The mean follow-up was 16 years (range: 13-19 years). The radiation therapy was individually planned. It included the chest wall (and the breast in the preoperative cases) and the regional lymph nodes. The tumor dose was 45 Gy/5 weeks. No adjuvant systemic therapy was used. The results showed a significant benefit with radiation therapy in terms of recurrence-free survival during the entire follow-up period. There was also an overall survival difference - corresponding to 16% reduction of deaths - in favour of the irradiated patients which, however, was not statistically significant (p=0.09). Among those 169 patients who developed loco-regional recurrences long-term control was only achieved in about one-third of the cases. This figure was similar among those who had received adjuvant radiation therapy (34%) compared to those initially treated with surgery alone (32%). This implied that the overall proportion of patients who eventually developed uncontrolled local disease was significantly higher among those initially allocated to surgery alone (16%) compared to those allocated to pre- or postoperative radiation therapy (6%, p<0.01). These results suggest that local undertreatment may be deleterious in subgroups of patients. (author) 5 tabs

  16. Scattering by a slab containing randomly located cylinders: comparison between radiative transfer and electromagnetic simulation.

    Science.gov (United States)

    Roux, L; Mareschal, P; Vukadinovic, N; Thibaud, J B; Greffet, J J

    2001-02-01

    This study is devoted to the examination of scattering of waves by a slab containing randomly located cylinders. For the first time to our knowledge, the complete transmission problem has been solved numerically. We have compared the radiative transfer theory with a numerical solution of the wave equation. We discuss the coherent effects, such as forward-scattering dip and backscattering enhancement. It is seen that the radiative transfer equation can be used with great accuracy even for optically thin systems whose geometric thickness is comparable with the wavelength. We have also shown the presence of dependent scattering.

  17. Scattering and radiative properties of semi-external versus external mixtures of different aerosol types

    International Nuclear Information System (INIS)

    Mishchenko, Michael I.; Liu Li; Travis, Larry D.; Lacis, Andrew A.

    2004-01-01

    The superposition T-matrix method is used to compute the scattering of unpolarized light by semi-external aerosol mixtures in the form of polydisperse, randomly oriented two-particle clusters with touching components. The results are compared with those for composition-equivalent external aerosol mixtures, in which the components are widely separated and scatter light in isolation from each other. It is concluded that aggregation is likely to have a relatively weak effect on scattering and radiative properties of two-component tropospheric aerosols and can be replaced by the much simpler external-mixture model in remote sensing studies and atmospheric radiation balance computations

  18. Radiation therapy for metastatic lesions from breast cancer. Breast cancer metastasis to bone

    International Nuclear Information System (INIS)

    Hayashi, Shinya; Hoshi, Hiroaki

    2000-01-01

    This paper summarizes radiation therapy in the treatment of bone metastases from breast cancer. Bone metastasis occurs in approximately 70% of breast cancer patients, and the goals of radiation therapy for bone metastasis are: palliation of pain, prevention and treatment of neuropathic symptoms, and prevention of pathologic fractures. The prognosis of bone metastasis from breast cancer is known to be better than that of bone metastasis from other solid tumors. Local-field radiation, hemibody (or wide-field) radiation, and systemic radionuclide treatment are the major methods of radiation therapy for pain palliation. Although many studies have shown that breast cancer is more responsive to radiation therapy for pain palliation than other solid tumors, some studies found no significant difference. Local-field radiation therapy, which includes multi-fraction irradiation and single-fraction irradiation, is currently the most generally used method of radiotherapy for pain palliation. Pain palliation has been reported to be achieved in approximately 80% to 90% of patients treated with local-field external beam irradiation. Three types of multi-fraction irradiation therapy are administered depending on the prognosis: high-dose fraction irradiation (36-50 Gy/12-25 Fr/2.4-5 wk), short-course irradiation (20-30 Gy/10-15 Fr/2-3 wk), and ultra-short-course irradiation (15-25 Gy/2-5 Fr/1 wk). The most common irradiation schedule is 30 Gy/10 Fr/2 wk. Although many reports indicate no significant difference in pain palliation according to the dose, the percentage of patients who show a complete cure is significantly higher in those treated with doses of 30 Gy or more, and thus the total irradiation dose should be at least 30 Gy. High-dose fraction irradiation is indicated for patients with an expected survival time of 6 months or more while short-course or single-fraction irradiation is indicated for those with an expected survival time of 3 months or more. Single

  19. Absorption and scattering of laser radiation by the diffusion flame of aviation kerosene

    International Nuclear Information System (INIS)

    Gvozdev, S V; Glova, A F; Dubrovskii, V Yu; Durmanov, S T; Krasyukov, A G; Lysikov, A Yu; Smirnov, G V; Solomakhin, V B

    2012-01-01

    The absorption coefficient of the radiation of a repetitively pulsed Nd : YAG laser with an average output power up to 6 W and of a cw ytterbium optical fibre laser with an output power up to 3 kW was measured in the diffusion flame of aviation kerosene burning on a free surface in the atmospheric air. The absorption coefficient as a function of flame length, radiation power, and radiation intensity, which was varied in the ∼10 3 - 5×10 4 W cm -2 range, was obtained for two distances (1 and 2 cm) between the laser beam axis and the surface. The coefficient of radiation absorption by kerosene flame was compared with that in ethanol and kerosene - ethanol mixture flames. The radiation power scattered by a small segment of the kerosene flame irradiated by Nd : YAG laser radiation was measured as a function of longitudinal and azimuthal coordinates. An estimate was made of the total scattered radiation power.

  20. Absorption and scattering of laser radiation by the diffusion flame of aviation kerosene

    Science.gov (United States)

    Gvozdev, S. V.; Glova, A. F.; Dubrovskii, V. Yu; Durmanov, S. T.; Krasyukov, A. G.; Lysikov, A. Yu; Smirnov, G. V.; Solomakhin, V. B.

    2012-04-01

    The absorption coefficient of the radiation of a repetitively pulsed Nd : YAG laser with an average output power up to 6 W and of a cw ytterbium optical fibre laser with an output power up to 3 kW was measured in the diffusion flame of aviation kerosene burning on a free surface in the atmospheric air. The absorption coefficient as a function of flame length, radiation power, and radiation intensity, which was varied in the ~103 — 5×104 W cm-2 range, was obtained for two distances (1 and 2 cm) between the laser beam axis and the surface. The coefficient of radiation absorption by kerosene flame was compared with that in ethanol and kerosene — ethanol mixture flames. The radiation power scattered by a small segment of the kerosene flame irradiated by Nd : YAG laser radiation was measured as a function of longitudinal and azimuthal coordinates. An estimate was made of the total scattered radiation power.

  1. Experiment on direct nn scattering - The radiation-induced outgassing complication

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, S.L., E-mail: sstephen@gettysburg.edu [Gettysburg College, Gettysburg, PA 17325 (United States); Crawford, B.E. [Gettysburg College, Gettysburg, PA 17325 (United States); Furman, W.I.; Lychagin, E.V.; Muzichka, A.Yu.; Nekhaev, G.V.; Sharapov, E.I.; Shvetsov, V.N.; Strelkov, A.V. [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Levakov, B.G.; Lyzhin, A.E.; Chernukhin, Yu.I. [Russian Federal Nuclear Center - All Russian Research Institute of Technical Physics, P.O. Box 245, 456770 Snezhinsk (Russian Federation); Howell, C.R. [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Mitchell, G.E. [North Carolina State University, Raleigh, NC 27695-8202 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W. [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Showalter-Bucher, R.A. [Northeastern University, Boston, MA 02115 (United States)

    2012-12-01

    The first direct neutron-neutron scattering experiment using the YAGUAR pulsed reactor has yielded initial results. They show a unforeseen significant thermal neutron background as a result of radiation-induced desorption within the scattering chamber. Thermal neutrons are mostly scattering not from other neutrons but instead from the desorbed gas molecules. Analysis of the obtained neutron time-of-flight spectra suggests neutron scattering from H{sub 2} molecules. The presented desorption model agrees with our experimental value of the desorption yield {eta}{sub {gamma}}=0.02 molecules/gamma. Possible techniques to reduce the effect of the desorption background are presented.

  2. A Note on the Radiative and Collisional Branching Ratios in Polarized Radiation Transport with Coherent Scattering

    Science.gov (United States)

    Casini, R.; del Pino Alemán, T.; Manso Sainz, R.

    2017-02-01

    We discuss the implementation of physically meaningful branching ratios between the CRD and partial redistribution contributions to the emissivity of a polarized multi-term atom in the presence of both inelastic and elastic collisions. Our derivation is based on a recent theoretical formulation of partially coherent scattering, and it relies on a heuristic diagrammatic analysis of the various radiative and collisional processes to determine the proper form of the branching ratios. The expression we obtain for the emissivity is {\\boldsymbol{\\varepsilon }}=[{{\\boldsymbol{\\varepsilon }}}(1)-{{\\boldsymbol{\\varepsilon }}}{{f}.{{s}}.}(2)]+{{\\boldsymbol{\\varepsilon }}}(2), where {{\\boldsymbol{\\varepsilon }}}(1) and {{\\boldsymbol{\\varepsilon }}}(2) are the emissivity terms for the redistributed and partially coherent radiation, respectively, and where “f.s.” implies that the corresponding term must be evaluated assuming a flat-spectrum average of the incident radiation. This result is shown to be in agreement with prior literature on the subject in the limit of the unpolarized multi-level atom.

  3. Breast cancer induced by radiation. Relation to mammography and treatment of acne

    International Nuclear Information System (INIS)

    Simon, N.

    1977-01-01

    A report is given of cases of 16 women in whom cancer of the breast developed after radiation therapy for acne or hirsutism, suggesting another group at higher risk than is generally expected for cancer of the breast. It is prudent to regard the carcinogenic effect of radiation on the breast as proportional to dose without a threshold. Mammography in young women should be ordered only selectively, not for screening

  4. Electromagnetic radiation and scattering from small canonical structures of double-negative metamaterials

    DEFF Research Database (Denmark)

    Arslanagic, Samel

    2007-01-01

    aspects associated with DNG materials, and was subsequently extended to investigations of the radiation and scattering from two- and three-dimensional (2D and 3D) MTM-based canonical problems in electromagnetic theory. As to the theoretical aspects of DNG materials, the sign, or more generally the branch......, cylindrical and spherical configurations to design electrically small, resonant structures such as cavities, waveguides, scatterers and radiators. These ideas are extended here to canonical antenna and scattering configurations which consist of electrically small resonant cylindrical and spherical MTM......-based structures excited by an arbitrarily located electric line source and an arbitrarily located and oriented electric Hertzian dipole, respectively. Exact analytical solutions, based on eigenfunction series, are derived and then numerically evaluated to study the radiation and scattering from these structures...

  5. Application of the 2-D discrete-ordinates method to multiple scattering of laser radiation

    International Nuclear Information System (INIS)

    Zardecki, A.; Gerstl, S.A.W.; Embury, J.F.

    1983-01-01

    The discrete-ordinates finite-element radiation transport code twotran is applied to describe the multiple scattering of a laser beam from a reflecting target. For a model scenario involving a 99% relative humidity rural aerosol we compute the average intensity of the scattered radiation and correction factors to the Beer-Lambert law arising from multiple scattering. As our results indicate, 2-D x-y and r-z geometry modeling can reliably describe a realistic 3-D scenario. Specific results are presented for the two visual ranges of 1.52 and 0.76 km which show that, for sufficiently high aerosol concentrations (e.g., equivalent to V = 0.76 km), the target signature in a distant detector becomes dominated by multiply scattered radiation from interactions of the laser light with the aerosol environment. The merits of the scaling group and the delta-M approximation for the transfer equation are also explored

  6. Optical characterization of thin female breast biopsies based on the reduced scattering coefficient

    International Nuclear Information System (INIS)

    Garofalakis, A; Zacharakis, G; Filippidis, G; Sanidas, E; Tsiftsis, D D; Stathopoulos, E; Kafousi, M; Ripoll, J; Papazoglou, T G

    2005-01-01

    One of the main goals in optical characterization of biopsies is to discern between tissue types. Usually, the theory used for deriving the optical properties of such highly scattering media is based on the diffusion approximation. However, biopsies are usually small in size compared to the transport mean free path and thus cannot be treated with standard diffusion theory. To account for this, an improved theory was developed, by the authors, that can correctly describe light propagation in small geometries (Garofalakis et al 2004 J. Opt. A: Pure Appl. Opt. 6 725-35). The theory's limit was validated by both Monte Carlo simulations and experiments performed on tissue-like phantoms, and was found to be two transport mean free paths. With the aid of this theory, we have characterized 59 samples of breast tissue including cancerous samples by retrieving their reduced scattering coefficients from time-resolved transmission data. The mean values for the reduced scattering coefficients of the normal and the tumour tissue were measured to be 9.7 ± 2.2 cm -1 and 10.8 ± 1.8 cm -1 , respectively. The correlation with age was also investigated

  7. Multiple and dependent scattering by densely packed discrete spheres: Comparison of radiative transfer and Maxwell theory

    International Nuclear Information System (INIS)

    Ma, L.X.; Tan, J.Y.; Zhao, J.M.; Wang, F.Q.; Wang, C.A.

    2017-01-01

    The radiative transfer equation (RTE) has been widely used to deal with multiple scattering of light by sparsely and randomly distributed discrete particles. However, for densely packed particles, the RTE becomes questionable due to strong dependent scattering effects. This paper examines the accuracy of RTE by comparing with the exact electromagnetic theory. For an imaginary spherical volume filled with randomly distributed, densely packed spheres, the RTE is solved by the Monte Carlo method combined with the Percus–Yevick hard model to consider the dependent scattering effect, while the electromagnetic calculation is based on the multi-sphere superposition T-matrix method. The Mueller matrix elements of the system with different size parameters and volume fractions of spheres are obtained using both methods. The results verify that the RTE fails to deal with the systems with a high-volume fraction due to the dependent scattering effects. Apart from the effects of forward interference scattering and coherent backscattering, the Percus–Yevick hard sphere model shows good accuracy in accounting for the far-field interference effects for medium or smaller size parameters (up to 6.964 in this study). For densely packed discrete spheres with large size parameters (equals 13.928 in this study), the improvement of dependent scattering correction tends to deteriorate. The observations indicate that caution must be taken when using RTE in dealing with the radiative transfer in dense discrete random media even though the dependent scattering correction is applied. - Highlights: • The Muller matrix of randomly distributed, densely packed spheres are investigated. • The effects of multiple scattering and dependent scattering are analyzed. • The accuracy of radiative transfer theory for densely packed spheres is discussed. • Dependent scattering correction takes effect at medium size parameter or smaller. • Performance of dependent scattering correction

  8. A small-angle scattering study of bacteriophage T7 using synchrotron radiation

    International Nuclear Information System (INIS)

    Feigin, L.A.; Svergun, D.I.; Dembo, A.T.; Ronto, G.; Toth, K.

    1989-01-01

    Structure transitions in the bacterial virus T7, due to an environment of varying ionic strength, are investigated by means of synchrotron radiation small-angle scattering. Effects of radiation damages and kinetics of the structure transition are separated. Time dependencies of the structural parameters and distribution functions are obtained and characteristic features of the structure rearrangements are described. (orig.)

  9. Electron scattering in large water clusters from photoelectron imaging with high harmonic radiation.

    Science.gov (United States)

    Gartmann, Thomas E; Hartweg, Sebastian; Ban, Loren; Chasovskikh, Egor; Yoder, Bruce L; Signorell, Ruth

    2018-06-06

    Low-energy electron scattering in water clusters (H2O)n with average cluster sizes of n < 700 is investigated by angle-resolved photoelectron spectroscopy using high harmonic radiation at photon energies of 14.0, 20.3, and 26.5 eV for ionization from the three outermost valence orbitals. The measurements probe the evolution of the photoelectron anisotropy parameter β as a function of cluster size. A remarkably steep decrease of β with increasing cluster size is observed, which for the largest clusters reaches liquid bulk values. Detailed electron scattering calculations reveal that neither gas nor condensed phase scattering can explain the cluster data. Qualitative agreement between experiment and simulations is obtained with scattering calculations that treat cluster scattering as an intermediate case between gas and condensed phase scattering.

  10. Light scattering by multiple spheres: comparison between Maxwell theory and radiative-transfer-theory calculations.

    Science.gov (United States)

    Voit, Florian; Schäfer, Jan; Kienle, Alwin

    2009-09-01

    We present a methodology to compare results of classical radiative transfer theory against exact solutions of Maxwell theory for a high number of spheres. We calculated light propagation in a cubic scattering region (20 x 20 x 20 microm(3)) consisting of different concentrations of polystyrene spheres in water (diameter 2 microm) by an analytical solution of Maxwell theory and by a numerical solution of radiative transfer theory. The relative deviation of differential as well as total scattering cross sections obtained by both approaches was evaluated for each sphere concentration. For the considered case, we found that deviations due to radiative transfer theory remain small, even for concentrations up to ca. 20 vol. %.

  11. Radiation therapy for metastatic lesions from breast cancer. Breast cancer metastasis to bone

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Shinya; Hoshi, Hiroaki [Gifu Univ. (Japan). School of Medicine

    2000-10-01

    This paper summarizes radiation therapy in the treatment of bone metastases from breast cancer. Bone metastasis occurs in approximately 70% of breast cancer patients, and the goals of radiation therapy for bone metastasis are: palliation of pain, prevention and treatment of neuropathic symptoms, and prevention of pathologic fractures. The prognosis of bone metastasis from breast cancer is known to be better than that of bone metastasis from other solid tumors. Local-field radiation, hemibody (or wide-field) radiation, and systemic radionuclide treatment are the major methods of radiation therapy for pain palliation. Although many studies have shown that breast cancer is more responsive to radiation therapy for pain palliation than other solid tumors, some studies found no significant difference. Local-field radiation therapy, which includes multi-fraction irradiation and single-fraction irradiation, is currently the most generally used method of radiotherapy for pain palliation. Pain palliation has been reported to be achieved in approximately 80% to 90% of patients treated with local-field external beam irradiation. Three types of multi-fraction irradiation therapy are administered depending on the prognosis: high-dose fraction irradiation (36-50 Gy/12-25 Fr/2.4-5 wk), short-course irradiation (20-30 Gy/10-15 Fr/2-3 wk), and ultra-short-course irradiation (15-25 Gy/2-5 Fr/1 wk). The most common irradiation schedule is 30 Gy/10 Fr/2 wk. Although many reports indicate no significant difference in pain palliation according to the dose, the percentage of patients who show a complete cure is significantly higher in those treated with doses of 30 Gy or more, and thus the total irradiation dose should be at least 30 Gy. High-dose fraction irradiation is indicated for patients with an expected survival time of 6 months or more while short-course or single-fraction irradiation is indicated for those with an expected survival time of 3 months or more. Single

  12. Systemic scleroderma diagnosed after undergoing radiation therapy for breast cancer

    International Nuclear Information System (INIS)

    Sasaki, Tetsuo; Kakei, Masae

    1994-01-01

    A case of systemic scleroderma in which the symptoms became prominent after undergoing radiation therapy for breast cancer is reported. A 68-year-old woman, who had undergone a radical mastectomy for breast carcinoma at the age of 63 and thereafter received radiotherapy at 65, 66 and 67 years of age, visited our clinic complaining of skin sclerosis and Raynaud's phenomenon which she had noticed since the age of 65. The physical examination revealed not only postirradiation fibrosis and pigmentation, but also edematous sclerosis and the pigmentation of her extremities, as well as short frenulum of the tongue and digital pitting scars. She demonstrated serum anti-topoisomerase I antibodies, esophageal dysfunction and lung fibrosis. The histopathology of the forearm skin showed edema of the upper dermis as well as increased and homogenized collagen bundles in the middle and lower dermis. Since similar cases have been reported, it is considerable that radiation therapy may have thus worsened the lesions of scleroderma in this patient as well. (author)

  13. Systemic scleroderma diagnosed after undergoing radiation therapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Tetsuo; Kakei, Masae (Yokohama City Univ. (Japan). Faculty of Medicine)

    1994-10-01

    A case of systemic scleroderma in which the symptoms became prominent after undergoing radiation therapy for breast cancer is reported. A 68-year-old woman, who had undergone a radical mastectomy for breast carcinoma at the age of 63 and thereafter received radiotherapy at 65, 66 and 67 years of age, visited our clinic complaining of skin sclerosis and Raynaud's phenomenon which she had noticed since the age of 65. The physical examination revealed not only postirradiation fibrosis and pigmentation, but also edematous sclerosis and the pigmentation of her extremities, as well as short frenulum of the tongue and digital pitting scars. She demonstrated serum anti-topoisomerase I antibodies, esophageal dysfunction and lung fibrosis. The histopathology of the forearm skin showed edema of the upper dermis as well as increased and homogenized collagen bundles in the middle and lower dermis. Since similar cases have been reported, it is considerable that radiation therapy may have thus worsened the lesions of scleroderma in this patient as well. (author).

  14. Nongray radiative heat transfer analysis in the anisotropic scattering fog layer subjected to solar irradiation

    International Nuclear Information System (INIS)

    Maruyama, Shigenao; Mori, Yusuke; Sakai, Seigo

    2004-01-01

    Radiative heat transfer in the fog layer is analyzed. Direct and diffuse solar irradiation, and infrared sky flux are considered as incident radiation. Anisotropic scattering of radiation by water droplets is taken into account. Absorption and emission of radiation by water droplets and radiative gases are also considered. Furthermore, spectral dependences of radiative properties of irradiation, reflectivity, gas absorption and scattering and absorption of mist are considered. The radiation element method by ray emission model (REM 2 ) is used for the nongray radiation analysis. Net downward radiative heat flux at the sea surface and radiative equilibrium temperature distribution in the fog layer are calculated for several conditions. Transmitted solar flux decreases as liquid water content (LWC) in the fog increases. However, the value does not become zero but has the value about 60 W/m 2 . The effect of humidity and mist on radiative cooling at night is investigated. Due to high temperature and humidity condition, the radiation cooling at night is not so large even in the clear sky. Furthermore, the radiative equilibrium temperature distribution in the fog layer in the daytime is higher as LWC increases, and the inversion layer of temperature occurs

  15. Modeling of high‐frequency seismic‐wave scattering and propagation using radiative transfer theory

    Science.gov (United States)

    Zeng, Yuehua

    2017-01-01

    This is a study of the nonisotropic scattering process based on radiative transfer theory and its application to the observation of the M 4.3 aftershock recording of the 2008 Wells earthquake sequence in Nevada. Given a wide range of recording distances from 29 to 320 km, the data provide a unique opportunity to discriminate scattering models based on their distance‐dependent behaviors. First, we develop a stable numerical procedure to simulate nonisotropic scattering waves based on the 3D nonisotropic scattering theory proposed by Sato (1995). By applying the simulation method to the inversion of M 4.3 Wells aftershock recordings, we find that a nonisotropic scattering model, dominated by forward scattering, provides the best fit to the observed high‐frequency direct S waves and S‐wave coda velocity envelopes. The scattering process is governed by a Gaussian autocorrelation function, suggesting a Gaussian random heterogeneous structure for the Nevada crust. The model successfully explains the common decay of seismic coda independent of source–station locations as a result of energy leaking from multiple strong forward scattering, instead of backscattering governed by the diffusion solution at large lapse times. The model also explains the pulse‐broadening effect in the high‐frequency direct and early arriving S waves, as other studies have found, and could be very important to applications of high‐frequency wave simulation in which scattering has a strong effect. We also find that regardless of its physical implications, the isotropic scattering model provides the same effective scattering coefficient and intrinsic attenuation estimates as the forward scattering model, suggesting that the isotropic scattering model is still a viable tool for the study of seismic scattering and intrinsic attenuation coefficients in the Earth.

  16. Compton scatter imaging: A promising modality for image guidance in lung stereotactic body radiation therapy.

    Science.gov (United States)

    Redler, Gage; Jones, Kevin C; Templeton, Alistair; Bernard, Damian; Turian, Julius; Chu, James C H

    2018-03-01

    Lung stereotactic body radiation therapy (SBRT) requires delivering large radiation doses with millimeter accuracy, making image guidance essential. An approach to forming images of patient anatomy from Compton-scattered photons during lung SBRT is presented. To investigate the potential of scatter imaging, a pinhole collimator and flat-panel detector are used for spatial localization and detection of photons scattered during external beam therapy using lung SBRT treatment conditions (6 MV FFF beam). MCNP Monte Carlo software is used to develop a model to simulate scatter images. This model is validated by comparing experimental and simulated phantom images. Patient scatter images are then simulated from 4DCT data. Experimental lung tumor phantom images have sufficient contrast-to-noise to visualize the tumor with as few as 10 MU (0.5 s temporal resolution). The relative signal intensity from objects of different composition as well as lung tumor contrast for simulated phantom images agree quantitatively with experimental images, thus validating the Monte Carlo model. Scatter images are shown to display high contrast between different materials (lung, water, bone). Simulated patient images show superior (~double) tumor contrast compared to MV transmission images. Compton scatter imaging is a promising modality for directly imaging patient anatomy during treatment without additional radiation, and it has the potential to complement existing technologies and aid tumor tracking and lung SBRT image guidance. © 2018 American Association of Physicists in Medicine.

  17. Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy.

    Science.gov (United States)

    Eftekhari, Mohammad; Anbiaei, Robabeh; Zamani, Hanie; Fallahi, Babak; Beiki, Davood; Ameri, Ahmad; Emami-Ardekani, Alireza; Fard-Esfahani, Armaghan; Gholamrezanezhad, Ali; Seid Ratki, Kazem Razavi; Roknabadi, Alireza Momen

    2015-01-01

    Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right-sided cancer. To minimize potential confounding factors, only those patients with low 10-year risk of coronary artery disease (based on Framingham risk scoring) were included. All patients were initially treated by modified radical mastectomy and then were managed by postoperative 3D Conformal Radiation Therapy (CRT) to the surgical bed with an additional 1-cm margin, delivered by 46-50 Gy (in 2 Gy daily fractions) over a 5-week course. The same dose-adjusted chemotherapy regimen (including anthracyclines, cyclophosphamide and taxol) was given to all patients. Six months after radiation therapy, all patients underwent cardiac SPECT for the evaluation of myocardial perfusion. A total of 71 patients with a mean age of 45.3±7.2 years [35 patients with leftsided breast cancer (exposed) and 36 patients with right-sided cancer (controls)] were enrolled. Dose-volume histogram (DVH) [showing the percentage of the heart exposed to >50% of radiation] was significantly higher in patients with left-sided breast cancer. Visual interpretation detected perfusion abnormalities in 42.9% of cases and 16.7% of controls (P=0.02, Odds ratio=1.46). In semiquantitative segmental analysis, only apical (28.6% versus 8.3%, P=0.03) and anterolateral (17.1% versus 2.8%, P=0.049) walls showed significantly reduced myocardial perfusion in the exposed group. Summed Stress Score (SSS) of>3 was observed in twelve cases (34.3%), while in five of the controls (13.9%),(Odds ratio=1.3). There was no significant difference between the groups regarding left ventricular ejection fraction. The risk of radiation induced myocardial perfusion abnormality in patients treated with CRT on the

  18. Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy

    Directory of Open Access Journals (Sweden)

    Mohammad Eftekhari

    2015-01-01

    Full Text Available Objective(s: Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding factors, only those patients with low 10-year risk of coronary artery disease (based on Framingham risk scoring were included. All patients were initially treated by modified radical mastectomy and then were managed by postoperative 3D Conformal Radiation Therapy (CRT to the surgical bed with an additional 1-cm margin, delivered by 46-50 Gy (in 2 Gy daily fractions over a 5-week course. The same dose-adjusted chemotherapy regimen (including anthracyclines, cyclophosphamide and taxol was given to all patients. Six months after radiation therapy, all patients underwent cardiac SPECT for the evaluation of myocardial perfusion. Results: A total of 71 patients with a mean age of 45.3±7.2 years [35 patients with leftsided breast cancer (exposed and 36 patients with right-sided cancer (controls] were enrolled. Dose-volume histogram (DVH [showing the percentage of the heart exposed to >50% of radiation] was significantly higher in patients with left-sided breast cancer. Visual interpretation detected perfusion abnormalities in 42.9% of cases and 16.7% of controls (P=0.02, Odds ratio=1.46. In semiquantitative segmental analysis, only apical (28.6% versus 8.3%, P=0.03 and anterolateral (17.1% versus 2.8%, P=0.049 walls showed significantly reduced myocardial perfusion in the exposed group. Summed Stress Score (SSS of>3 was observed in twelve cases (34.3%, while in five of the controls (13.9%,(Odds ratio=1.3. There was no significant difference between the groups regarding left ventricular ejection fraction. Conclusion: The risk of radiation induced myocardial

  19. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    International Nuclear Information System (INIS)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Mueller, P.; Ulm, G.

    2009-01-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  20. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Science.gov (United States)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Müller, P.; Ulm, G.

    2009-09-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  1. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Krumrey, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)], E-mail: Michael.Krumrey@ptb.de; Cibik, L.; Mueller, P.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

    2009-09-11

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  2. Radiation Gene-expression Signatures in Primary Breast Cancer Cells.

    Science.gov (United States)

    Minafra, Luigi; Bravatà, Valentina; Cammarata, Francesco P; Russo, Giorgio; Gilardi, Maria C; Forte, Giusi I

    2018-05-01

    In breast cancer (BC) care, radiation therapy (RT) is an efficient treatment to control localized tumor. Radiobiological research is needed to understand molecular differences that affect radiosensitivity of different tumor subtypes and the response variability. The aim of this study was to analyze gene expression profiling (GEP) in primary BC cells following irradiation with doses of 9 Gy and 23 Gy delivered by intraoperative electron radiation therapy (IOERT) in order to define gene signatures of response to high doses of ionizing radiation. We performed GEP by cDNA microarrays and evaluated cell survival after IOERT treatment in primary BC cell cultures. Real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR) was performed to validate candidate genes. We showed, for the first time, a 4-gene and a 6-gene signature, as new molecular biomarkers, in two primary BC cell cultures after exposure at 9 Gy and 23 Gy respectively, for which we observed a significantly high survival rate. Gene signatures activated by different doses of ionizing radiation may predict response to RT and contribute to defining a personalized biological-driven treatment plan. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  3. An analysis of the incidence and related factors for radiation dermatitis in breast cancer patients who receive radiation therapy

    International Nuclear Information System (INIS)

    Lee, Sun Young; Kwon, Hyoung Cheol; Kim, Jung Soo; Lee, Heui Kwan

    2010-01-01

    We analyzed the incidence and related factors of radiation dermatitis; at first, to recognize whether a decrease in radiation dermatitis is possible or not in breast cancer patients who received radiation therapy. Of 338 patients, 284 with invasive breast cancer who received breast conservation surgery with radiotherapy at Chonbuk National University Hospital from January 2007 to June 2009 were evaluated. Patients who also underwent bolus, previous contralateral breast irradiation and irradiation on both breasts were excluded. For patients who appeared to have greater than moderate radiation dermatitis, the incidence and relating factors for radiation dermatitis were analyzed retrospectively. A total of 207 and 77 patients appeared to have RTOG grade 0/1 or above RTOG grade 2 radiation dermatitis, respectively. The factors found to be statistically significant for the 77 patients who appeared to have greater than moderate radiation dermatitis include the presence of lymphocele due to the stasis of lymph and lymph edema which affect the healing disturbance of radiation dermatitis (p=0.003, p=0.001). Moreover, an allergic reaction to plaster due to the immune cells of skin and the activation of cytokine and concomitant hormonal therapy were also statistically significant factors (p=0.001, p=0.025). Most of the breast cancer patients who received radiation therapy appeared to have a greater than mild case of radiation dermatitis. Lymphocele, lymphedema, an allergy to plaster and concomitant hormonal therapy which affect radiation dermatitis were found to be significant factors. Consequently, we should eliminate lymphocele prior to radiation treatment for patients who appear to have an allergic reaction to plaster. We should also instruct patients of methods to maintain skin moisture if they appear to have a greater than moderate case of radiation dermatitis.

  4. Inelastic scattering in condensed matter with high intensity Moessbauer radiation

    International Nuclear Information System (INIS)

    Yelon, W.B.; Schupp, G.

    1993-02-01

    The QUEGS facility at MURR has produced a number of new results and demonstrated the range of potential applications of high resolution, high intensity Moessbauer scattering. This work has been carried out by both MU and Purdue researchers and includes published results on Na, W, pentadecane, polydimethylsiloxane and other systems, manuscripts submitted on alkali halides (Phys. Rev. B) and accurate Moessbauer lineshape measurements (Phys. Rev. C), and manuscripts in preparation on glycerol, NiAl and Moessbauer spectra obtained by modulating a scattering crystal. Recently, new collaborations have been initiated which will substantially enhance our efforts. These are with W. Steiner (Vienna), G. Coddens (Saclay), and R. D. Taylor (Los Alamos). Steiner is experienced with Fe-57 Moessbauer scattering, while Coddens specializes in quasielastic neutron scattering; both of these areas naturally complement our work. R. D. Taylor has pioneered Moessbauer spectroscopy from the time of its discovery and has already made important contributions to our study of lattice dynamics and superconductivity for lead alloyed with small quantities of tin. At the same time, a significant instrument upgrade is underway, funded in part by the DOE-URIP program

  5. Analysis of Scattered Radiation Influence on Detectability in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Gurvich, V [ALVIM R and D Ltd., P.O.B. 801 Jerusalem 91007 (Israel); Manevich, I [Jerusalem College of Technology, 21 Havaad Haleumi St. P.O.B. 16031, Jerusalem 91160 (Israel)

    1994-12-31

    The calculation of holes detectability in tissue equivalent materials on a X-ray image is implemented. In the calculation various values of scatter accumulation factor are used. The obtained results confirmed by experimental data may be useful for choice of physics-technical conditions of X-ray examination. (authors). 7 refs, 1 fig, 1 tab.

  6. Dosimetric evaluation of whole-breast radiation therapy: Clinical experience

    International Nuclear Information System (INIS)

    Osei, Ernest; Darko, Johnson; Fleck, Andre; White, Jana; Kiciak, Alexander; Redekop, Rachel; Gopaul, Darin

    2015-01-01

    Radiation therapy of the intact breast is the standard therapy for preventing local recurrence of early-stage breast cancer following breast conservation surgery. To improve patient standard of care, there is a need to define a consistent and transparent treatment path for all patients that reduces significance variations in the acceptability of treatment plans. There is lack of consistency among institutions or individuals about what is considered an acceptable treatment plan: target coverage vis-à-vis dose to organs at risk (OAR). Clinical trials usually resolve these issues, as the criteria for an acceptable plan within the trial (target coverage and doses to OAR) are well defined. We developed an institutional criterion for accepting breast treatment plans in 2006 after analyzing treatment data of approximately 200 patients. The purpose of this article is to report on the dosimetric review of 623 patients treated in the last 18 months to evaluate the effectiveness of the previously developed plan acceptability criteria and any possible changes necessary to further improve patient care. The mean patient age is 61.6 years (range: 25.2 to 93.0 years). The mean breast separation for all the patients is 21.0 cm (range: 12.4 to 34.9 cm), and the mean planning target volume (PTV-eval) (breast volume for evaluation) is 884.0 cm"3 (range: 73.6 to 3684.6 cm"3). Overall, 314 (50.4%) patients had the disease in the left breast and 309 (49.6%) had it in the right breast. A total of 147 (23.6%) patients were treated using the deep inspiration breath-hold (DIBH) technique. The mean normalized PTV-eval receiving at least 92% (V_9_2_% _P_D) and 95% (V_9_5_% _P_D) of the prescribed dose (PD) are more than 99% and 97%, respectively, for all patients. The mean normalized PTV-eval receiving at least 105% (V_1_0_5_% _P_D) of the PD is less than 1% for all groups. The mean homogeneity index (HI), uniformity index (UI), and conformity index (CI) for the PTV-eval are 0.09 (range: 0

  7. The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Braicovich, L., E-mail: lucio.braicovich@polimi.it; Minola, M.; Dellea, G.; Ghiringhelli, G. [CNR-SPIN and Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo Da Vinci 32, Milano I-20133 (Italy); Le Tacon, M. [Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart (Germany); Moretti Sala, M.; Morawe, C.; Peffen, J.-Ch.; Yakhou, F.; Brookes, N. B. [European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043 (France); Supruangnet, R. [Synchrotron Light Research Institute, Nakhon Ratchasima (Thailand)

    2014-11-15

    Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B{sub 4}C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L{sub 3} edge on a high-T{sub c} superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

  8. Post-radiation malignant fibrous histiocytoma following treatment of breast cancer: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jun Won; Lee, Won Ae; Kim, You Me [Dankook University College of Medicine, Seoul (Korea, Republic of)

    2013-10-15

    Post-radiation malignant fibrous histiocytoma (MFH) of the breast is extremely rare. We report a case of post-radiation MFH that presented a rapidly growing mass in a 52-year-old woman who underwent breast-conserving therapy and adjuvant whole breast irradiation 6 years ago. To the best of our knowledge, only one case of primary MFH of the female breast have been reported with sonographic findings. We analyzed the sonographic and MRI findings with correlative histopathologic features, and then confirmed with surgical excision.

  9. Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

    International Nuclear Information System (INIS)

    Huo, Jinhai; Giordano, Sharon H.; Smith, Benjamin D.; Shaitelman, Simona F.; Smith, Grace L.

    2016-01-01

    Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased

  10. Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Huo, Jinhai [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Giordano, Sharon H. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Shaitelman, Simona F. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Grace L., E-mail: glsmith@mdanderson.org [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-03-15

    Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased

  11. Radiative heat transfer in strongly forward scattering media using the discrete ordinates method

    Science.gov (United States)

    Granate, Pedro; Coelho, Pedro J.; Roger, Maxime

    2016-03-01

    The discrete ordinates method (DOM) is widely used to solve the radiative transfer equation, often yielding satisfactory results. However, in the presence of strongly forward scattering media, this method does not generally conserve the scattering energy and the phase function asymmetry factor. Because of this, the normalization of the phase function has been proposed to guarantee that the scattering energy and the asymmetry factor are conserved. Various authors have used different normalization techniques. Three of these are compared in the present work, along with two other methods, one based on the finite volume method (FVM) and another one based on the spherical harmonics discrete ordinates method (SHDOM). In addition, the approximation of the Henyey-Greenstein phase function by a different one is investigated as an alternative to the phase function normalization. The approximate phase function is given by the sum of a Dirac delta function, which accounts for the forward scattering peak, and a smoother scaled phase function. In this study, these techniques are applied to three scalar radiative transfer test cases, namely a three-dimensional cubic domain with a purely scattering medium, an axisymmetric cylindrical enclosure containing an emitting-absorbing-scattering medium, and a three-dimensional transient problem with collimated irradiation. The present results show that accurate predictions are achieved for strongly forward scattering media when the phase function is normalized in such a way that both the scattered energy and the phase function asymmetry factor are conserved. The normalization of the phase function may be avoided using the FVM or the SHDOM to evaluate the in-scattering term of the radiative transfer equation. Both methods yield results whose accuracy is similar to that obtained using the DOM along with normalization of the phase function. Very satisfactory predictions were also achieved using the delta-M phase function, while the delta

  12. The use of Compton scattering to differentiate between classifications of normal and diseased breast tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, Elaine A; Farquharson, Michael J; Flinton, David M [School of Allied Health Sciences, City University, Charterhouse Square, London EC1M 6PA (United Kingdom)

    2005-07-21

    This study describes a technique for measuring the electron density of breast tissue utilizing Compton scattered photons. The K{sub {alpha}}{sub 2} line from a tungsten target industrial x-ray tube (57.97 keV) was used and the scattered x-rays collected at an angle of 30{sup 0}. At this angle the Compton and coherent photon peaks can be resolved using an energy dispersive detector and a peak fitting algorithm. The system was calibrated using solutions of known electron density. The results obtained from a pilot study of 22 tissues are presented. The tissue samples investigated comprise four different tissue classifications: adipose, malignancy, fibroadenoma and fibrocystic change (FCC). It is shown that there is a difference between adipose and malignant tissue, to a value of 9.0%, and between adipose and FCC, to a value of 12.7%. These figures are found to be significant by statistical analysis. The differences between adipose and fibroadenoma tissues (2.2%) and between malignancy and FCC (3.4%) are not significant. It is hypothesized that the alteration in glucose uptake within malignant cells may cause these tissues to have an elevated electron density. The fibrotic nature of tissue that has undergone FCC gives the highest measure of all tissue types.

  13. The use of Compton scattering to differentiate between classifications of normal and diseased breast tissue

    Science.gov (United States)

    Ryan, Elaine A.; Farquharson, Michael J.; Flinton, David M.

    2005-07-01

    This study describes a technique for measuring the electron density of breast tissue utilizing Compton scattered photons. The Kα2 line from a tungsten target industrial x-ray tube (57.97 keV) was used and the scattered x-rays collected at an angle of 30°. At this angle the Compton and coherent photon peaks can be resolved using an energy dispersive detector and a peak fitting algorithm. The system was calibrated using solutions of known electron density. The results obtained from a pilot study of 22 tissues are presented. The tissue samples investigated comprise four different tissue classifications: adipose, malignancy, fibroadenoma and fibrocystic change (FCC). It is shown that there is a difference between adipose and malignant tissue, to a value of 9.0%, and between adipose and FCC, to a value of 12.7%. These figures are found to be significant by statistical analysis. The differences between adipose and fibroadenoma tissues (2.2%) and between malignancy and FCC (3.4%) are not significant. It is hypothesized that the alteration in glucose uptake within malignant cells may cause these tissues to have an elevated electron density. The fibrotic nature of tissue that has undergone FCC gives the highest measure of all tissue types.

  14. The use of Compton scattering to differentiate between classifications of normal and diseased breast tissue

    International Nuclear Information System (INIS)

    Ryan, Elaine A; Farquharson, Michael J; Flinton, David M

    2005-01-01

    This study describes a technique for measuring the electron density of breast tissue utilizing Compton scattered photons. The K α2 line from a tungsten target industrial x-ray tube (57.97 keV) was used and the scattered x-rays collected at an angle of 30 0 . At this angle the Compton and coherent photon peaks can be resolved using an energy dispersive detector and a peak fitting algorithm. The system was calibrated using solutions of known electron density. The results obtained from a pilot study of 22 tissues are presented. The tissue samples investigated comprise four different tissue classifications: adipose, malignancy, fibroadenoma and fibrocystic change (FCC). It is shown that there is a difference between adipose and malignant tissue, to a value of 9.0%, and between adipose and FCC, to a value of 12.7%. These figures are found to be significant by statistical analysis. The differences between adipose and fibroadenoma tissues (2.2%) and between malignancy and FCC (3.4%) are not significant. It is hypothesized that the alteration in glucose uptake within malignant cells may cause these tissues to have an elevated electron density. The fibrotic nature of tissue that has undergone FCC gives the highest measure of all tissue types

  15. Understanding the scatter radiation distribution during C-arm CT examination. A body phantom study

    International Nuclear Information System (INIS)

    Norimasa, Toshiyo; Kakimi, Akihiko; Takao, Yoshinori; Sasaki, Shohei; Katayama, Yutaka; Himoto, Daisuke; Izuta, Shinichiro; Ichida, Takao

    2016-01-01

    The purpose of this study was to understand the scatter radiation distribution during C-arm CT examination in the interventional radiography (IVR) room to show the escaped area and the radiation protective method. The C-arm rotates 200deg in 5 s. The tube voltage was 90 kV, and the entrance dose to the detector was 0.36 μGy/frame during C-arm CT examination. The scattered doses were measured each 50 cm from the isocenter like a grid pattern. The heights of the measurement were 50, 100, and 150 cm from the floor. The maximum scattered doses were 38.23 ± 0.60 μGy at 50 cm, 43.86 ± 20 μGy at 100 cm, and 25.78 ± 0.37 μGy at 150 cm. The scatter radiation distribution at 100 cm was the highest scattered dose. The operator should protect their reproductive gland, thyroid, and lens. The scattered dose was low behind the C-arm body and the bed, so they will be able to become the escaped area for staff. (author)

  16. Microstructural effect on radiative scattering coefficient and asymmetry factor of anisotropic thermal barrier coatings

    Science.gov (United States)

    Chen, X. W.; Zhao, C. Y.; Wang, B. X.

    2018-05-01

    Thermal barrier coatings are common porous materials coated on the surface of devices operating under high temperatures and designed for heat insulation. This study presents a comprehensive investigation on the microstructural effect on radiative scattering coefficient and asymmetry factor of anisotropic thermal barrier coatings. Based on the quartet structure generation set algorithm, the finite-difference-time-domain method is applied to calculate angular scattering intensity distribution of complicated random microstructure, which takes wave nature into account. Combining Monte Carlo method with Particle Swarm Optimization, asymmetry factor, scattering coefficient and absorption coefficient are retrieved simultaneously. The retrieved radiative properties are identified with the angular scattering intensity distribution under different pore shapes, which takes dependent scattering and anisotropic pore shape into account implicitly. It has been found that microstructure significantly affects the radiative properties in thermal barrier coatings. Compared with spherical shape, irregular anisotropic pore shape reduces the forward scattering peak. The method used in this paper can also be applied to other porous media, which designs a frame work for further quantitative study on porous media.

  17. Electromagnetic radiation of ultrarelativistic particles at scattering in excited medium

    International Nuclear Information System (INIS)

    Malyshevskij, V.S.

    1990-01-01

    The interaction between relativistic particles and a gaseous or condensed medium with a high density of nondegenerate excited quantum states involves the coherent conversion of atomic or molecular excitations into electromagnetic radiation

  18. Effects of the scattering anisotropy approximation in multigroup radiation shielding calculations

    International Nuclear Information System (INIS)

    Altiparmarkov, D.

    1983-01-01

    Expansion of the scattering cross-sections into Legendre series is the usual way of solving the neutron transport problem. Because of the large space gradients of the neutron flux, the effects of that approximations become especially remarkable in the radiation shielding calculations. In this paper, a method taking into account scattering anisotropy is presented. From the point of view of the accuracy and computing speed, the optimal approximation of the scattering anisotropy is established for the basic protective materials on the basis of simple problem calculations (author) [sr

  19. Small angle scattering of X radiation and slow neutrons in structural analyses of amorphous solids

    International Nuclear Information System (INIS)

    Kostorz, G.

    1980-01-01

    Small angle scattering of x radiation and slow neutrons allows to detect inhomogeneities of the dimension of ten to some thousands of Angstroem by the difference in the scattering length density. The progress made during recent years in the development of apparatusses has created the possibility of solving very complicated problems. A first outline shows that in separation processes as well as in investigating extended defects the method of small angle scattering may provide valuable contributions to the analysis of the non-crystalline state

  20. Breast-Conserving Surgery Followed by Radiation Therapy With MRI-Detected Stage I or Stage II Breast Cancer

    Science.gov (United States)

    2011-12-07

    Ductal Breast Carcinoma in Situ; Estrogen Receptor-negative Breast Cancer; Estrogen Receptor-positive Breast Cancer; HER2-negative Breast Cancer; HER2-positive Breast Cancer; Invasive Ductal Breast Carcinoma; Invasive Lobular Breast Carcinoma; Male Breast Cancer; Medullary Ductal Breast Carcinoma With Lymphocytic Infiltrate; Mucinous Ductal Breast Carcinoma; Papillary Ductal Breast Carcinoma; Progesterone Receptor-negative Breast Cancer; Progesterone Receptor-positive Breast Cancer; Stage I Breast Cancer; Stage II Breast Cancer; Tubular Ductal Breast Carcinoma

  1. Compton scattering spectrum as a source of information of normal and neoplastic breast tissues' composition

    Energy Technology Data Exchange (ETDEWEB)

    Antoniassi, M.; Conceicao, A.L.C. [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, 14040-901 Sao Paulo (Brazil); Poletti, M.E., E-mail: poletti@ffclrp.usp.br [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, 14040-901 Sao Paulo (Brazil)

    2012-07-15

    In this work we measured X-ray scatter spectra from normal and neoplastic breast tissues using photon energy of 17.44 keV and a scattering angle of 90 Degree-Sign , in order to study the shape (FWHM) of the Compton peaks. The obtained results for FWHM were discussed in terms of composition and histological characteristics of each tissue type. The statistical analysis shows that the distribution of FWHM of normal adipose breast tissue clearly differs from all other investigated tissues. Comparison between experimental values of FWHM and effective atomic number revealed a strong correlation between them, showing that the FWHM values can be used to provide information about elemental composition of the tissues. - Highlights: Black-Right-Pointing-Pointer X-ray scatter spectra from normal and neoplastic breast tissues were measured. Black-Right-Pointing-Pointer Shape (FWHM) of Compton peak was related with elemental composition and characteristics of each tissue type. Black-Right-Pointing-Pointer A statistical hypothesis test showed clear differences between normal and neoplastic breast tissues. Black-Right-Pointing-Pointer There is a strong correlation between experimental values of FWHM and effective atomic number. Black-Right-Pointing-Pointer Shape (FWHM) of Compton peak can be used to provide information about elemental composition of the tissues.

  2. Location of alien bodies in a media according to the data of scattering gamma radiation

    International Nuclear Information System (INIS)

    Vasil'ev, M.B.; Chuvashov, N.F.; Skuchaev, Yu.K.; Markov, V.I.

    1995-01-01

    Locations of alien bodies in a medium are studied by the method of model experiment using scattering γ-radiation. 60 Co and 137 Cs were used as radiation sources. The scattering bodies were made in the form of aluminium, iron and lead cylinders of different diameters inserted inside hollow cylindrical water, aluminium and iron media. The cases are reviewed when the alien bodies are in the center of cylindrical media. The obtained data are presented in the graphical form and in the form of tables. 4 refs., 4 figs. 1 tab

  3. Alcohol intake and cigarette smoking and risk of a contralateral breast cancer: The Women's Environmental Cancer and Radiation Epidemiology Study

    DEFF Research Database (Denmark)

    Knight, J.A.; Bernstein, L.; Largent, J.

    2009-01-01

    Women with primary breast cancer are at increased risk of developing second primary breast cancer. Few studies have evaluated risk factors for the development of asynchronous contralateral breast cancer in women with breast cancer. In the Women's Environmental Cancer and Radiation Epidemiology St...

  4. Search for the lowest irradiation dose from literatures on radiation-induced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Y; Kusama, T [Tokyo Univ. (Japan). Faculty of Medicine

    1975-12-01

    A survey of past case reports concerning radiation-induced breast cancer was carried out in order to find the lowest irradiation dose. The search of literature published since 1951 revealed 10 cases of radiation-induced breast cancer. Only 5 cases had precise descriptions of the irradiation dose. The lowest irradiation dose was estimated at 1470 rads in the case of external X-ray irradiation for tuberous angioma. All of cases of radiation-induced breast cancer had received radiation for the treatment of nonmalignant tumors, such as pulmonary tuberculosis, mastitis, and tuberous angioma. There also were three statistical studies. The first concerned atomic bomb survivors, the second, pulmoanry tuberculous patients subjected to frequent fluoroscopies, and the third, patients of acute post partum mastitis. These statistical studies had revealed a significant increase in the incidence of breast cancer in the irradiated group, but there was little information about the lowest irradiation dose. It was noticed that radiation-induced breast cancer was more numerous in the upper inner quadrant of the breast. Most histopathological findings of radiation-induced breast cancer involved duct cell carcinoma. The latent period was about 15 years.

  5. Structural-electrical coupling optimisation for radiating and scattering performances of active phased array antenna

    Science.gov (United States)

    Wang, Congsi; Wang, Yan; Wang, Zhihai; Wang, Meng; Yuan, Shuai; Wang, Weifeng

    2018-04-01

    It is well known that calculating and reducing of radar cross section (RCS) of the active phased array antenna (APAA) are both difficult and complicated. It remains unresolved to balance the performance of the radiating and scattering when the RCS is reduced. Therefore, this paper develops a structure and scattering array factor coupling model of APAA based on the phase errors of radiated elements generated by structural distortion and installation error of the array. To obtain the optimal radiating and scattering performance, an integrated optimisation model is built to optimise the installation height of all the radiated elements in normal direction of the array, in which the particle swarm optimisation method is adopted and the gain loss and scattering array factor are selected as the fitness function. The simulation indicates that the proposed coupling model and integrated optimisation method can effectively decrease the RCS and that the necessary radiating performance can be simultaneously guaranteed, which demonstrate an important application value in engineering design and structural evaluation of APAA.

  6. Several problems of the theory of transition radiation and transition scattering

    International Nuclear Information System (INIS)

    Ginzburg, V.L.; Tsytovich, V.N.

    1979-01-01

    The process of transition radiation is a very general one. It appears if some source, which does not have a proper frequency (for example a point charge, multipole etc), is moving with a constant velocity in an inhomogeneous and/or nonstationary medium. In the case of a periodic medium the transition radiation has some special peculiarities and is called the resonance transition radiation or transition scattering. Transition scattering occurs particularly in the case when some wave of dielectric permittivity acts on a nonmoving (fixed) charge. The processes of transition radiation and transition scattering have analogies outside electrodynamics similarly to the Vavilov-Cherenkov emission. The latter occurs also for a source moving with a constant velocity but in a homogeneous medium (and only if the velocity of the source exceeds the wave phase velocity in the medium). The present review is dealing with several problems of the theory of transition radiation and transition scattering. Attention is paid mainly to the formulation of the problems and to revealing characterisic features and peculiarities of the phenomena described. (Auth.)

  7. Investigations on image improvement in radiodiagnosis under special consideration of reducing scattered radiation

    International Nuclear Information System (INIS)

    Becker, R.

    1976-10-01

    In the study, image improvement is proposed for scintiscanning, X-ray and neutron diagnosis as well as computer axial tomography. In order to reduce the scattered radiation, mainly two-dimensional radiation transport calculations are carried out, and the imaging properties are studied by simulation on a large computer. It was found, among other things, that in contrast to X-ray techniques, in diagnosis with fast neutrons the image quality can hardly be improved by screens for scattered radiation. Here the problem of scattered radiation can only be solved by using scanners with narrow beams. The new method of neutron diagnosis resulting from this is especially suited for representing structures behind bones or for the localization of bone tumors invisible to X-rays, but not for representing fatty tissue. For large depths of irradiation, the scattered radiation with neutron sources below 1 MeV gets so intensive that diagnosis becomes impossible. When fast neutrons are used are used, the method is applicable for computer axial tomography because of the narrow beams. (ORU) [de

  8. Direct time-domain techniques for transient radiation and scattering

    International Nuclear Information System (INIS)

    Miller, E.K.; Landt, J.A.

    1976-01-01

    A tutorial introduction to transient electromagnetics, focusing on direct time-domain techniques, is presented. Physical, mathematical, numerical, and experimental aspects of time-domain methods, with emphasis on wire objects excited as antennas or scatters are examined. Numerous computed examples illustrate the characteristics of direct time-domain procedures, especially where they may offer advantages over procedures in the more familiar frequency domain. These advantages include greater solution efficiency for many types of problems, the ability to handle nonlinearities, improved physical insight and interpretability, availability of wide-band information from a single calculation, and the possibility of isolating interactions among various parts of an object using time-range gating

  9. SCATTER

    International Nuclear Information System (INIS)

    Broome, J.

    1965-11-01

    The programme SCATTER is a KDF9 programme in the Egtran dialect of Fortran to generate normalized angular distributions for elastically scattered neutrons from data input as the coefficients of a Legendre polynomial series, or from differential cross-section data. Also, differential cross-section data may be analysed to produce Legendre polynomial coefficients. Output on cards punched in the format of the U.K. A. E. A. Nuclear Data Library is optional. (author)

  10. Impact of the Radiation Boost on Outcomes After Breast-Conserving Surgery and Radiation

    International Nuclear Information System (INIS)

    Murphy, Colin; Anderson, Penny R.; Li Tianyu; Bleicher, Richard J.; Sigurdson, Elin R.; Goldstein, Lori J.; Swaby, Ramona; Denlinger, Crystal; Dushkin, Holly; Nicolaou, Nicos; Freedman, Gary M.

    2011-01-01

    Purpose: We examined the impact of radiation tumor bed boost parameters in early-stage breast cancer on local control and cosmetic outcomes. Methods and Materials: A total of 3,186 women underwent postlumpectomy whole-breast radiation with a tumor bed boost for Tis to T2 breast cancer from 1970 to 2008. Boost parameters analyzed included size, energy, dose, and technique. Endpoints were local control, cosmesis, and fibrosis. The Kaplan-Meier method was used to estimate actuarial incidence, and a Cox proportional hazard model was used to determine independent predictors of outcomes on multivariate analysis (MVA). The median follow-up was 78 months (range, 1-305 months). Results: The crude cosmetic results were excellent in 54%, good in 41%, and fair/poor in 5% of patients. The 10-year estimate of an excellent cosmesis was 66%. On MVA, independent predictors for excellent cosmesis were use of electron boost, lower electron energy, adjuvant systemic therapy, and whole-breast IMRT. Fibrosis was reported in 8.4% of patients. The actuarial incidence of fibrosis was 11% at 5 years and 17% at 10 years. On MVA, independent predictors of fibrosis were larger cup size and higher boost energy. The 10-year actuarial local failure was 6.3%. There was no significant difference in local control by boost method, cut-out size, dose, or energy. Conclusions: Likelihood of excellent cosmesis or fibrosis are associated with boost technique, electron energy, and cup size. However, because of high local control and rare incidence of fair/poor cosmesis with a boost, the anatomy of the patient and tumor cavity should ultimately determine the necessary boost parameters.

  11. Beam size effects in the radiative Bhabha scattering

    International Nuclear Information System (INIS)

    Szczekowski, M.

    1990-01-01

    In some electromagnetic processes the measured cross section can be substantially smaller than calculated in standard Quantum Electrodynamics. The process of single bremsstrahlung, e + e - → e + e - γ is an example of such effect. If the size of the effect for large angle γ radiation is similar to its magnitude at low angles, then standard calculations of the radiative Bahbha background to e.g. the reaction used in counting the number of neutrino generations, e + e - → νν-barγ, at LEP energies can be overestimated by 10-20%. 5 refs., 5 figs. (author)

  12. A prospective study of quality of life in breast cancer patients undergoing radiation therapy

    Directory of Open Access Journals (Sweden)

    Canhua Xiao, PhD, RN

    2016-01-01

    Conclusions: Radiation therapy did not worsen QOL in breast cancer patients. However, pre-radiation therapy patient characteristics including BMI and perceived stress may be used to identify women who may experience decreased physical and mental function during and up to 1 year after radiation therapy.

  13. Scattered radiation from dental metallic crowns in head and neck radiotherapy.

    Science.gov (United States)

    Shimozato, T; Igarashi, Y; Itoh, Y; Yamamoto, N; Okudaira, K; Tabushi, K; Obata, Y; Komori, M; Naganawa, S; Ueda, M

    2011-09-07

    We aimed to estimate the scattered radiation from dental metallic crowns during head and neck radiotherapy by irradiating a jaw phantom with external photon beams. The phantom was composed of a dental metallic plate and hydroxyapatite embedded in polymethyl methacrylate. We used radiochromic film measurement and Monte Carlo simulation to calculate the radiation dose and dose distribution inside the phantom. To estimate dose variations in scattered radiation under different clinical situations, we altered the incident energy, field size, plate thickness, plate depth and plate material. The simulation results indicated that the dose at the incident side of the metallic dental plate was approximately 140% of that without the plate. The differences between dose distributions calculated with the radiation treatment-planning system (TPS) algorithms and the data simulation, except around the dental metallic plate, were 3% for a 4 MV photon beam. Therefore, we should carefully consider the dose distribution around dental metallic crowns determined by a TPS.

  14. Radiative corrections to high-energy neutrino scattering

    International Nuclear Information System (INIS)

    Rujula, A. de; Petronzio, R.; Savoy-Navarro, A.

    1979-01-01

    Motivated by precise neutrino experiments, the electromagnetic radiative corrections to the data are reconsidered. The usefulness is investigated and the simplicity demonstrated of the 'leading log' approximation: the calculation to order α ln (Q/μ), α ln (Q/msub(q)). Here Q is an energy scale of the overall process, μ is the lepton mass and msub(q) is a hadronic mass, the effective quark mass in a parton model. The leading log radiative corrections to dsigma/dy distributions and to suitably interpreted dsigma/dx distributions are quark-mass independent. The authors improve upon the conventional leading log approximation and compute explicitly the largest terms that lie beyond the leading log level. In practice this means that the model-independent formulae, though approximate, are likely to be excellent estimates everywhere except at low energy or very large y. It is pointed out that radiative corrections to measurements of deviations from the Callan-Gross relation and to measurements of the 'sea' constituency of nucleons are gigantic. The QCD inspired study of deviations from scaling is of particular interest. The authors compute, beyond the leading log level, the radiative corrections of the QCD predictions. (Auth.)

  15. COMPARISON OF HYPOFRACTIONATED RADIATION THERAPY VERSUS CONVENTIONAL RADIATION THERAPY IN POST MASTECTOMY BREAST CANCER

    Directory of Open Access Journals (Sweden)

    Abhilash

    2016-03-01

    Full Text Available INTRODUCTION Breast cancer is the most common cancer in women worldwide and a leading cause of cancer death in females and accounts for 1.8 million new cases and approximately 0.5 million deaths annually. Patients who present with locally advanced breast cancer (LABC require multidisciplinary team approach that incorporates diagnostic imaging, surgery, chemotherapy and histopathological assessment, including molecular-based studies, radiation, and, if indicated, biologic and hormonal therapies. Hypofractionated radiation therapy following mastectomy has been used in many institutions for several decades and have demonstrated equivalent local control, cosmetic and normal tissues between 50 Gy in 25 fractions and various hypofractionated radiotherapy prescriptions employing 13-16 fractions. Evidence suggests that hypofractionated radiotherapy may also be safe and effective for regional nodal disease. AIMS AND OBJECTIVES To compare the local control and side effects of hypofractionated radiation therapy with conventional radiation therapy in post mastectomy carcinoma breast with stage II and III and to compare the tolerability and compliance of both schedules. MATERIALS AND METHODS The study was conducted on 60 histopathologically proven patients of carcinoma of breast, treated surgically with modified radical mastectomy. Group I patients were given external radiation to chest flap and drainage areas, a dose of 39 Gy/13 fractions/3.1 weeks, a daily dose 3 Gy for 13 fractions in 4 days a week schedule and Group II patients were given external radiation to chest flap and drainage areas, a dose of 50 Gy/25 fractions/5 weeks, to receive a daily dose 2 Gy for 25 fractions in a 5 days a week schedule. RESULTS The median age at presentation in Group I and II was 48 and 50 years respectively. Locoregional control after completion of radiotherapy in Group I vs. Group II was 26/30 (86.7% vs. 27/30 (90% respectively. Acute reactions and their grades in Group

  16. Violation of the factorization theorem in large-angle radiative Bhabha scattering

    International Nuclear Information System (INIS)

    Arbuzov, A.B.; Kuraev, Eh.A.; Shajkhatdenov, B.G.

    1998-01-01

    The lowest order QED radiative corrections to the radiative large-angle Bhabha scattering process in the region where all the kinematical invariants are large compared to the electron mass are considered. We show that the leading logarithmic corrections do not factor before the Born cross section, contrary to the picture assumed in the renormalization group approach. Estimation of the leading and nonleading contributions for typical kinematics of the hard process for energy of Φ factory is done

  17. Radiation-associated breast tumors display a distinct gene expression profile

    NARCIS (Netherlands)

    Broeks, Annegien; Braaf, Linde M.; Wessels, Lodewyk F. A.; van de Vijver, Marc; de Bruin, Marie L.; Stovall, Marilyn; Russell, Nicola S.; van Leeuwen, Flora E.; van 't Veer, Laura J.

    2010-01-01

    PURPOSE: Women who received irradiation for Hodgkin's lymphoma have a strong increased risk for developing breast cancer. Approximately 90% of the breast cancers in these patients can be attributed to their radiation treatment, rendering such series extremely useful to determine whether a common

  18. Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyungsang; Ye, Jong Chul, E-mail: jong.ye@kaist.ac.kr [Bio Imaging and Signal Processing Laboratory, Department of Bio and Brain Engineering, KAIST 291, Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of); Lee, Taewon; Cho, Seungryong [Medical Imaging and Radiotherapeutics Laboratory, Department of Nuclear and Quantum Engineering, KAIST 291, Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of); Seong, Younghun; Lee, Jongha; Jang, Kwang Eun [Samsung Advanced Institute of Technology, Samsung Electronics, 130, Samsung-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 443-803 (Korea, Republic of); Choi, Jaegu; Choi, Young Wook [Korea Electrotechnology Research Institute (KERI), 111, Hanggaul-ro, Sangnok-gu, Ansan-si, Gyeonggi-do, 426-170 (Korea, Republic of); Kim, Hak Hee; Shin, Hee Jung; Cha, Joo Hee [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 138-736 (Korea, Republic of)

    2015-09-15

    Purpose: In digital breast tomosynthesis (DBT), scatter correction is highly desirable, as it improves image quality at low doses. Because the DBT detector panel is typically stationary during the source rotation, antiscatter grids are not generally compatible with DBT; thus, a software-based scatter correction is required. This work proposes a fully iterative scatter correction method that uses a novel fast Monte Carlo simulation (MCS) with a tissue-composition ratio estimation technique for DBT imaging. Methods: To apply MCS to scatter estimation, the material composition in each voxel should be known. To overcome the lack of prior accurate knowledge of tissue composition for DBT, a tissue-composition ratio is estimated based on the observation that the breast tissues are principally composed of adipose and glandular tissues. Using this approximation, the composition ratio can be estimated from the reconstructed attenuation coefficients, and the scatter distribution can then be estimated by MCS using the composition ratio. The scatter estimation and image reconstruction procedures can be performed iteratively until an acceptable accuracy is achieved. For practical use, (i) the authors have implemented a fast MCS using a graphics processing unit (GPU), (ii) the MCS is simplified to transport only x-rays in the energy range of 10–50 keV, modeling Rayleigh and Compton scattering and the photoelectric effect using the tissue-composition ratio of adipose and glandular tissues, and (iii) downsampling is used because the scatter distribution varies rather smoothly. Results: The authors have demonstrated that the proposed method can accurately estimate the scatter distribution, and that the contrast-to-noise ratio of the final reconstructed image is significantly improved. The authors validated the performance of the MCS by changing the tissue thickness, composition ratio, and x-ray energy. The authors confirmed that the tissue-composition ratio estimation was quite

  19. Evaluation of Breast Sentinel Lymph Node Coverage by Standard Radiation Therapy Fields

    International Nuclear Information System (INIS)

    Rabinovitch, Rachel; Ballonoff, Ari; Newman, Francis M.S.; Finlayson, Christina

    2008-01-01

    Background: Biopsy of the breast sentinel lymph node (SLN) is now a standard staging procedure for early-stage invasive breast cancer. The anatomic location of the breast SLN and its relationship to standard radiation fields has not been described. Methods and Materials: A retrospective review of radiotherapy treatment planning data sets was performed in patients with breast cancer who had undergone SLN biopsy, and those with a surgical clip at the SLN biopsy site were identified. The location of the clip was evaluated relative to vertebral body level on an anterior-posterior digitally reconstructed radiograph, treated whole-breast tangential radiation fields, and standard axillary fields in 106 data sets meeting these criteria. Results: The breast SLN varied in vertebral body level position, ranging from T2 to T7 but most commonly opposite T4. The SLN clip was located below the base of the clavicle in 90%, and hence would be excluded from standard axillary radiotherapy fields where the inferior border is placed at this level. The clip was within the irradiated whole-breast tangent fields in 78%, beneath the superior-posterior corner multileaf collimators in 12%, and outside the tangent field borders in 10%. Conclusions: Standard axillary fields do not encompass the lymph nodes at highest risk of containing tumor in breast cancer patients. Elimination of the superior-posterior corner MLCs from the tangent field design would result in inclusion of the breast SLN in 90% of patients treated with standard whole-breast irradiation

  20. High dose and low dose radiation exposure in the induction of breast cancer

    International Nuclear Information System (INIS)

    Fernandez-Vicioso, E.; Ruiz-Cruces, R.; Pastor Vega, Jose M.

    2001-01-01

    In today's modern practice of Radiation Oncology it is becoming increasingly common to follow many patients with breast cancer. There is a proven association between prior radiation and the development of breast cancer, although in many instances the available sources of data are confusing. Characteristic features of radiation induced breast cancer are the importance of age at first exposure to radiation and the long latency period. The risk of breast cancer is highest in women exposed in the first decade of life and lessens progressively with increased age at exposure. The latency period is typically 10 years or more; a time in which other age dependent factors may influence the expression of the malignant phenotype. Genetic factors may also (in theory) increase a particular patient's susceptibility. (author)

  1. Radiation recall secondary to adjuvant docetaxel after balloon-catheter based accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Wong, Nathan W.; Wong, William W.; Karlin, Nina J.; Gray, Richard J.

    2010-01-01

    For early stage breast cancer, wide local excision and post-operative whole breast irradiation is a standard treatment. If adjuvant chemotherapy is recommended, radiation is usually given after completion of chemotherapy. In recent years, accelerated partial breast irradiation (APBI) with balloon-cathetered based brachytherapy has become an option for selected patients. For these patients, adjuvant chemotherapy would have to be administered after radiation. The sequence of treatment with radiation followed by chemotherapy results in increased risk of radiation recall reaction (RRD) in these patients. Docetaxel is becoming a more commonly used drug as adjuvant treatment for breast cancer. Here we report a case of docetaxel induced RRD after APBI with balloon-cathetered based brachytherapy. Such reaction would have an adverse impact on the cosmetic outcome and quality of life of the patient. For patients who develop an intense skin reaction after the administration of docetaxel following APBI, RRD should be considered in the differential diagnosis.

  2. [Gamma scattering in condensed matter with high intensity Moessbauer radiation

    International Nuclear Information System (INIS)

    1989-01-01

    There are four areas where major progress has occurred this year. We have applied the Fourier-transform method of describing and analyzing Moessbauer effect (ME) line shapes to make measurements of the temperature dependence of the recoilless fraction in tungsten. We have carried out quasi-elastic measurements of the gamma scattering from viscous liquids, learning about diffusive motion in polydimethylsiloxane, pentadecane, and glycerol. We have made major progress in fundamental physics, having shown for the first time how to determine precise quantum interference parameters, obtaining experimental results on the 46.5 keV line of 183 W and the 129 keV line of 191 Ir. Finally, we have continued our development of MICE detectors, with a theoretical analysis of the MICE lineshape and its relation to the lineshape of conventional transmission ME spectroscopy. 12 refs

  3. The application of correlation techniques to the angular spectrum of scattered radiation from tokamak plasmas

    International Nuclear Information System (INIS)

    Nazikian, R.

    1990-07-01

    In the limit of the first Born approximation for a partially coherent secondary source, consisting of a spatially random plasma illuminated by a coherent plane wave, it is shown that the spectral coherence of the scattered radiation as measured on an arbitrary plane beyond the scatterer conveys information on the three dimensional intensity distribution of the random source. By defining a new two point statistical measure of the random field, closely related to the cross spectral density, we show that the fluctuation amplitude of the random source along the direction of the incident plane wave may by recovered from the measurement of the scattered radiation. The application of cross spectral techniques to fluctuation studies on tokamaks is considered. 7 refs

  4. Solution of the radiative transfer equation for Rayleigh scattering using the infinite medium Green's function

    Science.gov (United States)

    Biçer, M.; Kaşkaş, A.

    2018-03-01

    The infinite medium Green's function is used to solve the half-space albedo, slab albedo and Milne problems for the unpolarized Rayleigh scattering case; these problems are the most classical problems of radiative transfer theory. The numerical results are obtained and are compared with previous ones.

  5. Nuclear resonant scattering of synchrotron radiation from nuclei in the Brownian motion

    International Nuclear Information System (INIS)

    Razdan, Ashok

    2003-01-01

    The time evolution of the coherent forward scattering of the synchrotron radiation for resonant nuclei in Brownian motion is studied. Apart from target thickness, the appearance of the dynamical beats also depends on 'α' which is the ratio of the harmonic force constant to the damping force constant of harmonic oscillator undergoing Brownian motion

  6. Investigation of vacuum polarization in t-channel radiative Bhabha scattering

    CERN Document Server

    Karlen, D A

    2001-01-01

    We discuss the possibility of a precision measurement of vacuum polarization in t-channel radiative Bhabha scattering at a high luminosity collider. For illustration, the achievable precision is estimated for the BaBar experiment at PEP-II and for the OPAL experiment at LEP.

  7. Study of radiative corrections with application to the electron-neutrino scattering

    International Nuclear Information System (INIS)

    Oliveira, L.C.S. de.

    1977-01-01

    The radiative correction method is studied which appears in Quantum Field Theory, for some weak interaction processes. e.g., Beta decay and muon decay. Such a method is then applied to calculate transition probability for the electron-neutrino scattering using the U-A theory as a base. The calculations of infrared and ultraviolet divergences are also discussed. (L.C.) [pt

  8. Examination of the component of the scattered radiation by external monitor chamber using the EGS4

    International Nuclear Information System (INIS)

    Shiota, Y.; Tabushi, K.; Kito, S.

    2005-01-01

    The output beams of the liner accelerator are radiated by an accelerated electron and a dose rate usually fluctuates. The variation affects the shape of a dose distribution in dosimetry. The external monitor chamber is often used for monitoring the variation. Generally the external monitor chamber is set above the water phantom. Therefore, if the irradiation field is small, the scattered radiation due to the external monitor chamber may affect a measurement dose. This work is to examine the component of the scattered radiation generated by external monitor chamber, and to investigate the effect on measurement dose using the EGS4 code and the Klein-Nishina formula. The shapes and the peak energies were corresponding to the spectra of EGS4 and the Klein-Nishina formula. Therefore the main interaction at the external monitor chamber is Compton scatter. The effect of the scattered radiation and the change of the dose distribution were few. However the dose decreased to about 1% under the position of the external monitor chamber. Therefore we should pay the attention to the distance between the external monitor chamber and the measurement chamber. (author)

  9. Application of correlation techniques to the angular spectrum of scattered radiation from tokamak plasmas

    International Nuclear Information System (INIS)

    Nazikian, R.

    1990-01-01

    In the limit of the first Born approximation for a partially coherent secondary source consisting of a spatially random plasma illuminated by a coherent plane wave, it is shown that the spectral coherence of the scattered radiation conveys information on the three-dimensional intensity distribution of the secondary source

  10. Evaluation of a method for correction of scatter radiation in thorax cone beam CT

    International Nuclear Information System (INIS)

    Rinkel, J.; Dinten, J.M.; Esteve, F.

    2004-01-01

    Purpose: Cone beam CT (CBCT) enables three-dimensional imaging with isotropic resolution. X-ray scatter estimation is a big challenge for quantitative CBCT imaging of thorax: scatter level is significantly higher on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation are cupping artefacts, streaks, and quantification inaccuracies. The beam stops conventional scatter estimation approach can be used for CBCT but leads to a significant increase in terms of dose and acquisition time. At CEA-LETI has been developed an original scatter management process without supplementary acquisition. Methods and Materials: This Analytical Plus Indexing-based method (API) of scatter correction in CBCT is based on scatter calibration through offline acquisitions with beam stops on lucite plates, combined to an analytical transformation issued from physical equations. This approach has been applied with success in bone densitometry and mammography. To evaluate this method in CBCT, acquisitions from a thorax phantom with and without beam stops have been performed. To compare different scatter correction approaches, Feldkamp algorithm has been applied on rough data corrected from scatter by API and by beam stops approaches. Results: The API method provides results in good agreement with the beam stops array approach, suppressing cupping artefact. Otherwise influence of the scatter correction method on the noise in the reconstructed images has been evaluated. Conclusion: The results indicate that the API method is effective for quantitative CBCT imaging of thorax. Compared to a beam stops array method it needs a lower x-ray dose and shortens acquisition time. (authors)

  11. Accelerated Radiation Therapy After Surgery in Treating Patients With Breast Cancer

    Science.gov (United States)

    2017-11-15

    Inflammatory Breast Cancer; Invasive Ductal Breast Carcinoma; Invasive Lobular Breast Carcinoma; Mucinous Ductal Breast Carcinoma; Papillary Ductal Breast Carcinoma; Stage II Breast Cancer; Stage IIIA Breast Cancer; Stage IIIB Breast Cancer; Stage IIIC Breast Cancer; Tubular Ductal Breast Carcinoma

  12. Assessment of ionizing radiation as a risk factor for breast cancer incidence in Goiania

    International Nuclear Information System (INIS)

    Lage, Leonardo Bastos

    2016-01-01

    study area was 102,91 cases per 100.000 and, outside the area, 46,86 ca ses per 100.000. These value s are within the range of average values presented by other Brazilian capitals, which is 130,99 cases per 100.000 in Porto Alegre-RS, and 20,04 cases in Macapa/AP, and the national average in the capital of 79,37 cases per 100.000 women. The cluster analysis showed a slight spatial correlation of crude rates of breast cancer incidence in three small sets of census tracts, far from the accident sources of contamination with Cesium-137. The scatter plot points and the R 2 value did not indicate any association between the crude rates of incidence and radiometric measurements. This study supports the hypothesis that ionizing radiation levels to which women living in Goiania are exposed, are not associated with the emergence of new cases of breast cancer. (author)

  13. Compression force and radiation dose in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Waade, Gunvor G.; Sanderud, Audun [Department of Life Sciences and Health, Faculty of Health Sciences, Oslo and Akershus University College of Applied Sciences, P.O. 4 St. Olavs Plass, 0130 Oslo (Norway); Hofvind, Solveig, E-mail: solveig.hofvind@kreftregisteret.no [Department of Life Sciences and Health, Faculty of Health Sciences, Oslo and Akershus University College of Applied Sciences, P.O. 4 St. Olavs Plass, 0130 Oslo (Norway); The Cancer Registry of Norway, P.O. 5313 Majorstuen, 0304 Oslo (Norway)

    2017-03-15

    Highlights: • Compression force and radiation dose for 17 951 screening mammograms were analyzed. • Large variations in mean applied compression force between the breast centers. • Limited associations between compression force and radiation dose. - Abstract: Purpose: Compression force is used in mammography to reduce breast thickness and by that decrease radiation dose and improve image quality. There are no evidence-based recommendations regarding the optimal compression force. We analyzed compression force and radiation dose between screening centers in the Norwegian Breast Cancer Screening Program (NBCSP), as a first step towards establishing evidence-based recommendations for compression force. Materials and methods: The study included information from 17 951 randomly selected screening examinations among women screened with equipment from four different venors at fourteen breast centers in the NBCSP, January-March 2014. We analyzed the applied compression force and radiation dose used on craniocaudal (CC) and mediolateral-oblique (MLO) view on left breast, by breast centers and vendors. Results: Mean compression force used in the screening program was 116N (CC: 108N, MLO: 125N). The maximum difference in mean compression force between the centers was 63N for CC and 57N for MLO. Mean radiation dose for each image was 1.09 mGy (CC: 1.04mGy, MLO: 1.14mGy), varying from 0.55 mGy to 1.31 mGy between the centers. Compression force alone had a negligible impact on radiation dose (r{sup 2} = 0.8%, p = < 0.001). Conclusion: We observed substantial variations in mean compression forces between the breast centers. Breast characteristics and differences in automated exposure control between vendors might explain the low association between compression force and radiation dose. Further knowledge about different automated exposure controls and the impact of compression force on dose and image quality is needed to establish individualised and evidence

  14. Radiation induced depigmentation disorder in two patients with breast cancer: Exploring a rare accompaniment

    International Nuclear Information System (INIS)

    Biswas, A.; Chaudhari, P.B.; Julka, P.K.; Rath, G.K.

    2015-01-01

    Abstract Radiation induced depigmentation disorder is a rare accompaniment. We herein report two patients of bilateral breast cancer developing depigmentation disorder, initially confined to the radiation portal with subsequent generalization within few months of completion of whole breast radiotherapy. Both these patients had no prior history of vitiligo or other autoimmune disorder. This brief report highlights the importance of awareness of this association in appropriate decision making in susceptible patients thereby preventing this morbidity and its psychological ramifications

  15. Estimates of the Spectral Aerosol Single Sea Scattering Albedo and Aerosol Radiative Effects during SAFARI 2000

    Science.gov (United States)

    Bergstrom, Robert W.; Pilewskie, Peter; Schmid, Beat; Russell, Philip B.

    2003-01-01

    Using measurements of the spectral solar radiative flux and optical depth for 2 days (24 August and 6 September 2000) during the SAFARI 2000 intensive field experiment and a detailed radiative transfer model, we estimate the spectral single scattering albedo of the aerosol layer. The single scattering albedo is similar on the 2 days even though the optical depth for the aerosol layer was quite different. The aerosol single scattering albedo was between 0.85 and 0.90 at 350 nm, decreasing to 0.6 in the near infrared. The magnitude and decrease with wavelength of the single scattering albedo are consistent with the absorption properties of small black carbon particles. We estimate the uncertainty in the single scattering albedo due to the uncertainty in the measured fractional absorption and optical depths. The uncertainty in the single scattering albedo is significantly less on the high-optical-depth day (6 September) than on the low-optical-depth day (24 August). On the high-optical-depth day, the uncertainty in the single scattering albedo is 0.02 in the midvisible whereas on the low-optical-depth day the uncertainty is 0.08 in the midvisible. On both days, the uncertainty becomes larger in the near infrared. We compute the radiative effect of the aerosol by comparing calculations with and without the aerosol. The effect at the top of the atmosphere (TOA) is to cool the atmosphere by 13 W/sq m on 24 August and 17 W/sq m on 6 September. The effect on the downward flux at the surface is a reduction of 57 W/sq m on 24 August and 200 W/sq m on 6 September. The aerosol effect on the downward flux at the surface is in good agreement with the results reported from the Indian Ocean Experiment (INDOEX).

  16. Calculation of radiation dose to infants from radioactive breast milk and suspensions necessary to constrain dose

    International Nuclear Information System (INIS)

    Cormack, J.; Shearer, J.

    2000-01-01

    Full text: For nuclear medicine patients who are breast feeding an infant, special radiation safety precautions may need to be taken. An estimate of the potential radiation dose to the child from ingested milk must be made, and breast-feeding may need to be suspended until levels of radioactivity in the breast-milk have fallen to acceptable levels. The risk of radiation to the child must be weighed against the benefits of breast-feeding and the possible trauma to both mother and child arising from interruption or cessation of the milk supply. In the United States, the Nuclear Regulatory Commission (NRC) has already published regulations which will necessitate an estimate of the infant's dose from breast milk to be made, in principle, for every breast-feeding patient. There is obviously, therefore, a need to provide a rapid and reliable means of estimating such doses. A spreadsheet template which automatically calculates the cumulative dose to breast feeding infants based on any multi-exponential clearance of activity from the breast milk, and any pattern of feeding, has been developed by the authors. The time (post administration) for which breast-feeding should be interrupted in order to constrain the radiation dose to a selected limit is also calculated along with the concentration of activity in breast milk at which feeding can resume. The effect of changing dose limits, feeding patterns and using individually derived breast milk clearance rates may be readily modelled using this spreadsheet template. Data has been included for many of the most commonly used radiopharmaceuticals and new data can readily be incorporated as it becomes available. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Determination of Atmospheric Aerosol Characteristics from the Polarization of Scattered Radiation

    Science.gov (United States)

    Harris, F. S., Jr.; McCormick, M. P.

    1973-01-01

    Aerosols affect the polarization of radiation in scattering, hence measured polarization can be used to infer the nature of the particles. Size distribution, particle shape, real and absorption parts of the complex refractive index affect the scattering. From Lorenz-Mie calculations of the 4-Stokes parameters as a function of scattering angle for various wavelengths the following polarization parameters were plotted: total intensity, intensity of polarization in plane of observation, intensity perpendicular to the plane of observation, polarization ratio, polarization (using all 4-Stokes parameters), plane of the polarization ellipse and its ellipticity. A six-component log-Gaussian size distribution model was used to study the effects of the nature of the polarization due to variations in the size distribution and complex refractive index. Though a rigorous inversion from measurements of scattering to detailed specification of aerosol characteristics is not possible, considerable information about the nature of the aerosols can be obtained. Only single scattering from aerosols was used in this paper. Also, the background due to Rayleigh gas scattering, the reduction of effects as a result of multiple scattering and polarization effects of possible ground background (airborne platforms) were not included.

  18. Intrafractional baseline drift during free breathing breast cancer radiation therapy.

    Science.gov (United States)

    Jensen, Christer Andre; Acosta Roa, Ana María; Lund, Jo-Åsmund; Frengen, Jomar

    2017-06-01

    Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.

  19. Radiation-induced cancer of the esophagus after postoperative irradiation for breast cancer

    International Nuclear Information System (INIS)

    Ito, Ichiro; Miyaishi, Kazuo; Mitsuhashi, Norio; Ito, Jun; Inoue, Tomio

    1978-01-01

    Two cases of radiation-induced cancer of the esophagus after postoperative irradiation for breast cancer were reported. Latent period of case 1 (cervical esophagus) was 12 years, and case 2 (middle thoracic esophagus) was 16 years. Radiographically the lesions were both serrated, and histologically, case 1 was ''poorly differentiated'' and case 2 was ''moderately differentiated'' squamous cell carcinoma. Histological types of basic breast cancer were both papillotubular carcinomas. Previous irradiation doses were 4180 rads for case 1 and 1860 rads for case 2. The esophageal cancers were remarkably improved by radiation therapy. It should be emphasized that radiation therapy is useful for the radiation-induced cancer of the esophagus. (author)

  20. Probing droplets on superhydrophobic surfaces by synchrotron radiation scattering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Accardo, Angelo [Istituto Italiano di Tecnologia, Via Morego 30, Genova 16163 (Italy); Di Fabrizio, Enzo [KAUST (King Abdullah University of Science and Technology), Jeddah (Saudi Arabia); BIONEM Lab at University Magna Graecia, Campus Salvatore Venuta, Viale Europa 88100, Germaneto-Catanzaro (Italy); Limongi, Tania [KAUST (King Abdullah University of Science and Technology), Jeddah (Saudi Arabia); Marinaro, Giovanni [Istituto Italiano di Tecnologia, Via Morego 30, Genova 16163 (Italy); European Synchrotron Radiation Facility, BP 220, 38043 Grenoble Cedex (France); Riekel, Christian, E-mail: riekel@esrf.fr [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble Cedex (France)

    2014-06-10

    A comprehensive review about the use of micro- and nanostructured superhydrophobic surfaces as a tool for in situ X-ray scattering investigations of soft matter and biological materials. Droplets on artificially structured superhydrophobic surfaces represent quasi contact-free sample environments which can be probed by X-ray microbeams and nanobeams in the absence of obstructing walls. This review will discuss basic surface wettability concepts and introduce the technology of structuring surfaces. Quasi contact-free droplets are compared with contact-free droplets; processes related to deposition and evaporation on solid surfaces are discussed. Droplet coalescence based on the electrowetting effect allows the probing of short-time mixing and reaction processes. The review will show for several materials of biological interest that structural processes related to conformational changes, nucleation and assembly during droplet evaporation can be spatially and temporally resolved by raster-scan diffraction techniques. Orientational ordering of anisotropic materials deposited during solidification at pinning sites facilitates the interpretation of structural data.

  1. A case of sarcoma of the chest wall after radiation therapy for breast cancer

    International Nuclear Information System (INIS)

    Izumi, Junko; Nishi, Tsunehiro; Fukuuchi, Atsushi; Takanashi, Riichiro

    1998-01-01

    A case of radiation-induced sarcoma of the chest wall after radiation therapy for breast cancer is reported. A 69-year-old woman underwent mastectomy with axillary lymph node dissection followed by linac therapy of 50 Gy delivered to the left axilla, left supraclavicular area, and parasternal area. During therapy for bone and liver metastases, a tumor was noted in the left chest wall 15 years after radiation therapy. Incisional biopsy was performed. Histological diagnosis was spindle cell sarcoma. Radiation-induced sarcoma was suspected because the tumor developed 15 years after radiation therapy within the same area. Radiation-induced sarcoma is a rare tumor, but radiation therapy following breast-conserving therapy is widely employed. It is important to be aware of the possibility of radiation-induced sarcoma. (author)

  2. The sensitivity of the human breast to cancer induction by ionizing radiation

    International Nuclear Information System (INIS)

    Mole, R.H.

    1978-01-01

    Available evidence for the induction of cancer in the human breast by small doses of radiation is reviewed. A comparison is made of risk estimates for the frequency of breast cancer in excess of controls, per rad of ionizing radiation, resulting from multiple fluoroscopy, radiotherapy of non-malignant diseases of the breast, or the exposure of Japanese bomb survivors. The significance of the age at exposure is discussed, and consideration is given to the application of the evidence to practical problems in radiography, radiotherapy, screening by mammography, and radiological protection for occupational exposure. (U.K.)

  3. Sensitivity of the human breast to cancer induction by ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mole, R H [Medical Research Council, Harwell (UK). Radiobiological Research Unit

    1978-06-01

    Available evidence for the induction of cancer in the human breast by small doses of radiation is reviewed. A comparison is made of risk estimates for the frequency of breast cancer in excess of controls, per rad of ionizing radiation, resulting from multiple fluoroscopy, radiotherapy of non-malignant diseases of the breast, or the exposure of Japanese bomb survivors. The significance of the age at exposure is discussed, and consideration is given to the application of the evidence to practical problems in radiography, radiotherapy, screening by mammography, and radiological protection for occupational exposure.

  4. The results of local radiation application at organ-reserving treatment of breast cancer

    International Nuclear Information System (INIS)

    Yakimova, T.P.; Ponomar'ov, Yi.M.

    2006-01-01

    The purpose of the given study is the clinical morphological investigation of the breast cancer pre-operation radiotherapy effectiveness by the proposed method, and its influence to the apoptosis. The clinical morphological investigation has been carried out in 28 breast cancer patients, the treatment of which has been began with the pre-operation radiation therapy course by the dose large fractionating method on the breast gland with the local tumor radiation, inguinal lymph glands with the next execution of the organ-preserving operation. We can draw a conclusion, that this very method is effective, as it devitalizes the tumors, and gives the enough high indicator of survival

  5. Invited Review Terahertz Transmission, Scattering, Reflection, and Absorption—the Interaction of THz Radiation with Soils

    Science.gov (United States)

    Lewis, R. A.

    2017-07-01

    Terahertz radiation has been proposed as a useful tool in the study of soils and related materials from such diverse perspectives as detection of non-metallic landmines to improving soil fertility by agricultural charcoals produced by pyrolysis of organic material. The main barrier to such applications is that soils are rather opaque at terahertz frequencies. In this article, the main findings to date on the interaction of terahertz radiation with soils are reviewed, organized around the four phenomena of terahertz: transmission, scattering, reflection, and absorption. Terahertz transmission through soils is generally low and decreases with frequency. Terahertz scattering is evident in many THz-soil interactions, as the wavelength of the radiation is of the order of the particle size. Terahertz reflection is important to communications as these develop from the GHz into the THz band. Terahertz absorption on diluted soil samples has been demonstrated to be effective in identifying soil constituents, such as aromatic compounds, and soil contaminants, such as pesticides.

  6. Dermatologic radiotherapy and breast cancer

    International Nuclear Information System (INIS)

    Goldschmidt, H.; Gorson, R.O.; Lassen, M.

    1982-01-01

    This study was set up to provide quantitative data to evaluate unsubstantiated claims that improper dermatologic radiation techniques may cause breast cancer. A thin mylar window ionization rate meter placed at the location of the right breast of an Alderson-RANDO anthropomorphic phantom was used to measure direct and scatter radiation reaching the female breast during radiotherapy of the facial region (as given for acne). The results indicate that scatter doses are very small; they are influenced by radiation quality and the use or nonuse of a treatment cone. Quantitative risk estimates show that the very small risk of breast cancer induction can be reduced even further by the use of proper radiation protection measures. (orig.)

  7. Dermatologic radiotherapy and breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmidt, H.; Gorson, R.O.; Lassen, M.

    1982-03-01

    This study was set up to provide quantitative data to evaluate unsubstantiated claims that improper dermatologic radiation techniques may cause breast cancer. A thin mylar window ionization rate meter placed at the location of the right breast of an Alderson-RANDO anthropomorphic phantom was used to measure direct and scatter radiation reaching the female breast during radiotherapy of the facial region (as given for acne). The results indicate that scatter doses are very small; they are influenced by radiation quality and the use or nonuse of a treatment cone. Quantitative risk estimates show that the very small risk of breast cancer induction can be reduced even further by the use of proper radiation protection measures.

  8. Impact of prognostic factors for postmastectomy radiation therapy of breast cancer patients

    Science.gov (United States)

    Simonov, K. A.; Startseva, Zh. A.; Slonimskaya, E. M.; Velikaya, V. V.

    2017-09-01

    The study included 196 breast cancer patients with stages T1-3N0-3M0. The comprehensive therapy for breast cancer included surgical operation, chemotherapy, and radiotherapy. Multivariate analysis showed that multifocality growth of tumor (p = 0.004), high grade III (p = 0.008), two metastatic lymph nodes (p = 0.02) were associated with an increased risk of regional node failure in the patients with one to three positive lymph nodes. The prognostic models describing the probability of local recurrences of breast cancer were developed for individualization of the radiation therapy tactics. Postmastectomy radiation therapy in the patients with high-risk breast cancer treated with modified radical mastectomy improves locoregional control, breast cancer-specific survival, does not increase late toxicity.

  9. Estimated risk for secondary cancer in the contra-lateral breast following radiation therapy of breast cancer

    International Nuclear Information System (INIS)

    Johansen, Safora; Danielsen, Turi; Olsen, Dag Rune

    2008-01-01

    Purpose. To facilitate a discussion about the impact of dose heterogeneity on the risk for secondary contralateral breast (CB) cancer predicted with linear and non linear models associated with primary breast irradiation. Methods and materials. Dose volume statistics of the CB calculated for eight patients using a collapsed cone algorithm were used to predict the excess relative risk (ERR) for cancer induction in CB. Both linear and non-linear models were employed. A sensitivity analysis demonstrating the impact of different parameter values on calculated ERR for the eight patients was also included in this study. Results. A proportionality assumption was established to make the calculations with a linear and non-linear model comparable. ERR of secondary cancer predicted by the linear model varied considerably between the patients, while the predicted ERR for the same patients using the non-linear model showed very small variation. The predicted ERRs by the two models were indistinguishable for small doses, i.e. below ∼3 Gy. The sensitivity analysis showed that the quadratic component of the radiation-induction pre-malignant cell term is negligible for lower dose level. The ERR is highly sensitive to the value of agr1 and agr2. Conclusions. Optimization of breast cancer radiation therapy, where also the risk for radiation induced secondary malignancies in the contralateral breast is taken into account, requires robust and valid risk assessment. The linear dose-risk model does not account for the complexity in the mechanisms underlying the development of secondary malignancies following exposure to radiation; this is particularly important when estimating risk associated with highly heterogeneous dose distributions as is the case in the contralateral breast of women receiving breast cancer irradiation

  10. Absorption and scattering of laser radiation by the diffusion flame of aviation kerosene

    Energy Technology Data Exchange (ETDEWEB)

    Gvozdev, S V; Glova, A F; Dubrovskii, V Yu; Durmanov, S T; Krasyukov, A G; Lysikov, A Yu; Smirnov, G V; Solomakhin, V B

    2012-04-30

    The absorption coefficient of the radiation of a repetitively pulsed Nd : YAG laser with an average output power up to 6 W and of a cw ytterbium optical fibre laser with an output power up to 3 kW was measured in the diffusion flame of aviation kerosene burning on a free surface in the atmospheric air. The absorption coefficient as a function of flame length, radiation power, and radiation intensity, which was varied in the {approx}10{sup 3} - 5 Multiplication-Sign 10{sup 4} W cm{sup -2} range, was obtained for two distances (1 and 2 cm) between the laser beam axis and the surface. The coefficient of radiation absorption by kerosene flame was compared with that in ethanol and kerosene - ethanol mixture flames. The radiation power scattered by a small segment of the kerosene flame irradiated by Nd : YAG laser radiation was measured as a function of longitudinal and azimuthal coordinates. An estimate was made of the total scattered radiation power.

  11. Scattering and Diffraction of Electromagnetic Radiation: An Effective Probe to Material Structure

    Science.gov (United States)

    Xu, Yu-Lin

    2016-01-01

    Scattered electromagnetic waves from material bodies of different forms contain, in an intricate way, precise information on the intrinsic, geometrical and physical properties of the objects. Scattering theories, ever deepening, aim to provide dependable interpretation and prediction to the complicated interaction of electromagnetic radiation with matter. There are well-established multiple-scattering formulations based on classical electromagnetic theories. An example is the Generalized Multi-particle Mie-solution (GMM), which has recently been extended to a special version ? the GMM-PA approach, applicable to finite periodic arrays consisting of a huge number (e.g., >>106) of identical scattering centers [1]. The framework of the GMM-PA is nearly complete. When the size of the constituent unit scatterers becomes considerably small in comparison with incident wavelength, an appropriate array of such small element volumes may well be a satisfactory representation of a material entity having an arbitrary structure. X-ray diffraction is a powerful characterization tool used in a variety of scientific and technical fields, including material science. A diffraction pattern is nothing more than the spatial distribution of scattered intensity, determined by the distribution of scattering matter by way of its Fourier transform [1]. Since all linear dimensions entered into Maxwell's equations are normalized by wavelength, an analogy exists between optical and X-ray diffraction patterns. A large set of optical diffraction patterns experimentally obtained can be found in the literature [e.g., 2,3]. Theoretical results from the GMM-PA have been scrutinized using a large collection of publically accessible, experimentally obtained Fraunhofer diffraction patterns. As far as characteristic structures of the patterns are concerned, theoretical and experimental results are in uniform agreement; no exception has been found so far. Closely connected with the spatial distribution of

  12. Anomalous resonance-radiation energy-transfer rate in a scattering dispersive medium

    International Nuclear Information System (INIS)

    Shekhtman, V.L.

    1992-01-01

    This paper describes a generalization of the concept of group velocity as an energy-transfer rate in a dispersive medium with complex refractive index when the polaritons, which are energy carriers, undergo scattering, in contrast to the classical concept of the group velocity of free polaritons (i.e., without scattering in the medium). The concept of delay time from quantum multichannel-scattering, theory is used as the fundamental concept. Based on Maxwell's equations and the new mathematical Φ-function method, a consistent conceptual definition of group velocity in terms of the ratio of the coherent-energy flux density to the coherent-energy density is obtained for the first time, and a critical analysis of the earlier (Brillouin) understanding of energy-transfer rate is given in the light of radiation-trapping theory and the quantum theory of resonance scattering. The role of generalized group velocity is examined for the interpretation of the phenomenon of multiple resonance scattering, or radiation diffusion. The question of causality for the given problem is touched upon; a new relationship is obtained, called the microcausality condition, which limits the anomalous values of group velocity by way of the indeterminacy principle and the relativistic causality principle for macroscopic time intervals directly measurable in experiment, whereby attention is focused on the connection of the given microcausality condition and the well-known Wigner inequality for the time delay of spherical waves. 22 refs

  13. Increased risk of breast cancer in splenectomized patients undergoing radiation therapy for Hodgkin's disease

    International Nuclear Information System (INIS)

    Chung, Chung T.; Bogart, Jeffrey A.; Adams, James F.; Sagerman, Robert H.; Numann, Patricia J.; Tassiopoulos, Apostolos; Duggan, David B.

    1997-01-01

    Purpose: Second malignancies have been reported among patients who were treated by radiation therapy or chemotherapy alone or in combination. Studies have implied an increased risk of breast cancer in women who received radiotherapy as part of their treatment for Hodgkin's disease. This review was performed to determine if there is an association between splenectomy and subsequent breast cancer. Methods and Materials: One hundred and thirty-six female patients with histologically proven Hodgkin's disease were seen in the Division of Radiation Oncology between 1962 and 1985. All patients received mantle or mediastinal irradiation as part of their therapy. The risk of breast cancer was assessed and multiple linear regression analysis was performed on the following variables: patient age, stage, dose and extent of radiation field, time after completing radiation therapy, splenectomy, and chemotheraphy. Results: Breast cancer was observed in 11 of 74 splenectomized patients and in none of 62 patients not splenectomized. The mean follow-up was 13 years in splenectomized patients and 16 years, 7 months in nonsplenectomized patients. Nine patients developed invasive breast cancer and two developed ductal carcinoma in situ. Splenectomy was the only variable independently associated with an increased risk of breast cancer (p < 0.005) in multiple linear regression analysis; age, latency, and splenectomy considered together were also associated with an increased risk of breast cancer (p < 0.01). Conclusion: Our data show an increased risk of breast cancer in splenectomized patients who had treatment for Hodgkin's disease. A multiinstitutional survey may better define the influence of splenectomy relative to developing breast cancer in patients treated for Hodgkin's disease. The risk of breast cancer should be considered when recommending staging laparotomy, and we recommend close follow-up examination including routine mammograms for female patients successfully treated for

  14. Influence of Ceiling Suspended Screen Positioning to the Scatter Radiation Levels in Interventional Cardiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Bozovic, P.; Ciraj-Bjelac, O.; Antic, V.

    2013-01-01

    The objective of this paper is to identify the effects of the ceiling suspended screen position to the scatter radiation levels in the interventional cardiology. The scatter radiation in terms of ambient dose equivalent H * (10) was measured for various positions of protective screen in the positions of the first operator, nurse and radiographer, at elevations 100-190 cm and in four different angulations of the x-ray tube. To assess the effectiveness of the protective screen, the scattered dose was also measured in the absence of any protection in all four angulations and elevations. To simulate real clinical situation the measurements were performed in the presence of 30 cm PMMA phantom using standard clinical protocol. The utility of protective screen varied for different positions and angulations. Scatter radiation levels varied in the range 70 - 3400 μSv/h for the first operator, 140 - 3200 μSv/h for the nurse and 50 - 560 μSv/h for radiographer. Ceiling suspended screens can provide a substantial level of protection (up to factor 18) in interventional cardiology, but they have to be properly managed and positioned to achieve sufficient level of protection. The guidance for optimal protection is provided in the paper.(author)

  15. Risk of secondary malignancies after radiation therapy for breast cancer: Comprehensive results.

    Science.gov (United States)

    Burt, Lindsay M; Ying, Jian; Poppe, Matthew M; Suneja, Gita; Gaffney, David K

    2017-10-01

    To assess risks of secondary malignancies in breast cancer patients who received radiation therapy compared to patients who did not. The SEER database was used to identify females with a primary diagnosis of breast cancer as their first malignancy, during 1973-2008. We excluded patients with metastatic disease, age breast cancer recurrence, or who developed a secondary malignancy within 1 year of diagnosis. Standardized incidence ratios and absolute excess risk were calculated using SEER*Stat, version 8.2.1 and SAS, version 9.4. There were 374,993 patients meeting the inclusion criteria, with 154,697 who received radiation therapy. With a median follow-up of 8.9 years, 13% of patients (49,867) developed a secondary malignancy. The rate of secondary malignancies was significantly greater than the endemic rate in breast cancer patients treated without radiation therapy, (O/E 1.2, 95% CI 1.19-1.22) and with radiation therapy (O/E 1.33, 95% CI 1.31-1.35). Approximately 3.4% of secondary malignancies were attributable to radiation therapy. The increased risk of secondary malignancies in breast cancer patients treated with radiation therapy compared to those without was significant regardless of age at breast cancer diagnosis (p breast cancer patients both with and without radiation therapy compared to the general population. There was an increased risk in specific sites for patients treated with radiation therapy. This risk was most evident in young patients and who had longer latency periods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Gamma radiation compton scattering effect from the Ukrytie Object on the radiation situation at the Chernobyl' NPP territory

    International Nuclear Information System (INIS)

    Alekseeva, E.A.; Volkovich, A.G.; Koba, G.I.; Liksonov, V.I.; Stepanov, V.E.; Tyurin, A.S.; Urutskoev, L.I.; Chesnokov, A.V.

    1989-01-01

    With the aim of determination of the angular distribution of the gamma-radiation (GR) exposure dose rate (EDR) around the Ukrytie Object (UO) are described the measurement results of GR EDR in July 1988 at the territory, adjoining to UO. The conclusion is made that the main contribution into EDR ensures GR, scattered as a result of the Compton effect on air molecules and that the contribution of the NPP territory is small. 10 figs.; 3 tabs

  17. Effects of radiation scatter exposure on electrometer dose assessment in orthovoltage radiotherapy

    International Nuclear Information System (INIS)

    Butson, Martin J.; Yu, Peter K.N.; Cheung, Tsang; Oborn, B.M.

    2011-01-01

    During orthovoltage x-ray radiotherapy dosimetry, normal practice requires the use of a standard ionisation chamber and dedicated electrometer for dosimetry. In ideal conditions, the electrometer is positioned outside the treatment room to eliminate any effects from scatter radiation on dose measurement. However in some older designed rooms, there is no access portal for the chamber cable to run to an 'outside' position for the electrometer. As such the electrometer is positioned within the treatment room. This work quantifies the effects on measured charge when this occurs. Results have shown that with the electrometer positioned next to a solid water dosimetry stack and using a large 15 x 15 cm field at 250 kVp x-ray beam energy, charge results can deviate by up to ±17.2% depending on the polarity applied to the chamber compared to readings when the electrometer is outside the treatment room. It is assumed to be due to scatter radiation producing electrons in the amplifying circuit of the electrometer. Results are also shown when the electrometer is shielded by a 4 mm thick lead casing whilst inside the room which removes the scattering effect, providing the best case scenario when the electrometer must remain in the treatment room. Whilst it is well known that an electrometer should not be irradiated (even to scattered radiation), often small kilovoltage or orthovoltage rooms do not have a portal access for an electrometer to go outside. As such it would be recommended for a lead shield to be placed around the electrometer during irradiation if this was to occur to minimize dosimetric inaccuracies which may occur due to scattered radiation effects.

  18. Isospin breaking in pion-nucleon scattering at threshold by radiative processes

    CERN Document Server

    Ericson, Torleif Eric Oskar

    2006-01-01

    We investigate the dispersive contribution by radiative processes such as (pi- proton to neutron gamma) and (pi- proton to Delta gamma) to the pion-nucleon scattering lengths of charged pions in the heavy baryon limit. They give a large isospin violating contribution in the corresponding isoscalar scattering length, but only a small violation in the isovector one. These terms contribute 6.3(3)% to the 1s level shift of pionic hydrogen and give a chiral constant F_pi^2f_1=-25.8(8) MeV.

  19. Subdiffraction field localisation in the scattering of femtosecond laser radiation by a dielectric microsphere

    Energy Technology Data Exchange (ETDEWEB)

    Geints, Yu E; Zemlyanov, A A; Panina, E K [V.E. Zuev Institute of Atmospheric Optics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

    2014-01-31

    The time dynamics of the optical field was theoretically considered in the near-field diffraction zone in the scattering of a femtosecond laser pulse by a transparent spherical microparticle. The spatial region of field focusing by the particle (the 'photonic jet' zone) was investigated; the evolution of the jet shape and the peak intensity in this region were analysed. For the first time it was determined that an extremely tight optical field localisation to a subdiffraction size is possible at a certain (resonance) temporal stage of photonic jet development. (radiation scattering)

  20. Three-Year Outcomes of Breast Intensity-Modulated Radiation Therapy With Simultaneous Integrated Boost

    International Nuclear Information System (INIS)

    McDonald, Mark W.; Godette, Karen D.; Whitaker, Daisy J.; Davis, Lawrence W.; Johnstone, Peter A.S.

    2010-01-01

    Purpose: To report our clinical experience using breast intensity-modulated radiation therapy with simultaneous integrated boost (SIB-IMRT). Methods and Materials: Retrospective review identified 354 Stage 0 to III breast cancer patients treated with SIB-IMRT after conservative surgery between 2003 and 2006. The most common fractionation (89%) simultaneously delivered 1.8 Gy to the ipsilateral breast tissue and 2.14 Gy to the resection cavity, yielding a breast dose of 45 Gy (25 fractions) and cavity dose 59.92 Gy (28 fractions), biologically equivalent for tumor control to 45 Gy to the breast with sequential 16-Gy boost (33 fractions). Results: A total of 356 breasts in 354 patients were treated: 282 with invasive breast cancer, and 74 with ductal carcinoma in situ (DCIS). For left breast radiation, median cardiac V 15 was 2.9% and left ventricular V 15 1.7%. Median follow-up was 33 months (range, 4-73 months). Acute toxicity was Grade 1 in 57% of cases, Grade 2 in 43%, and Grade 3 in <1%. For invasive breast cancer, the 3-year overall survival was 97.6% and risk of any locoregional recurrence was 2.8%. For ductal carcinoma in situ, 3-year overall survival was 98% and risk of locoregional recurrence 1.4%. In 142 cases at a minimum of 3 years follow-up, global breast cosmesis was judged by physicians as good or excellent in 96.5% and fair in 3.5%. Conclusions: Breast SIB-IMRT reduced treatment duration by five fractions with a favorable acute toxicity profile and low cardiac dose for left breast treatment. At 3 years, locoregional control was excellent, and initial assessment suggested good or excellent cosmesis in a high percentage of evaluable patients.

  1. WE-DE-207B-12: Scatter Correction for Dedicated Cone Beam Breast CT Based On a Forward Projection Model

    Energy Technology Data Exchange (ETDEWEB)

    Shi, L; Zhu, L [Georgia Institute of Technology, Atlanta, GA (Georgia); Vedantham, S; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: The image quality of dedicated cone-beam breast CT (CBBCT) is fundamentally limited by substantial x-ray scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose to suppress x-ray scatter in CBBCT images using a deterministic forward projection model. Method: We first use the 1st-pass FDK-reconstructed CBBCT images to segment fibroglandular and adipose tissue. Attenuation coefficients are assigned to the two tissues based on the x-ray spectrum used for imaging acquisition, and is forward projected to simulate scatter-free primary projections. We estimate the scatter by subtracting the simulated primary projection from the measured projection, and then the resultant scatter map is further refined by a Fourier-domain fitting algorithm after discarding untrusted scatter information. The final scatter estimate is subtracted from the measured projection for effective scatter correction. In our implementation, the proposed scatter correction takes 0.5 seconds for each projection. The method was evaluated using the overall image spatial non-uniformity (SNU) metric and the contrast-to-noise ratio (CNR) with 5 clinical datasets of BI-RADS 4/5 subjects. Results: For the 5 clinical datasets, our method reduced the SNU from 7.79% to 1.68% in coronal view and from 6.71% to 3.20% in sagittal view. The average CNR is improved by a factor of 1.38 in coronal view and 1.26 in sagittal view. Conclusion: The proposed scatter correction approach requires no additional scans or prior images and uses a deterministic model for efficient calculation. Evaluation with clinical datasets demonstrates the feasibility and stability of the method. These features are attractive for clinical CBBCT and make our method distinct from other approaches. Supported partly by NIH R21EB019597, R21CA134128

  2. Radiation-induced brachial plexus neuropathy in breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, N.K.; Pfeiffer, P.; Mondrup, K.; Rose, C. (Odense Univ. Hospital (Denmark). Dept. of Neurology Odense Univ. Hospital (Denmark). Dept. of Clinical Neurophysiology Odense Univ. Hospital (Denmark). Dept. of Oncology R)

    1990-01-01

    The incidence and latency period of radiation-induced brachial plexopathy (RBP) were assessed in 79 breast cancer patients by a neurological follow-up examination at least 60 months (range 67-130 months) after the primary treatment. All patients were treated primarily with simple mastectomy, axillary nodal sampling and radiotherapy (RT). Postoperatively, pre- and postmenopausal patients were randomly allocated chemotherapy for antiestrogen treatment. All patients were recurrence-free at time of examination. Clinically, 35% (25-47%) of the patients had RBP; 19% (11-29%) had definite RBP, i.e. were physically disabled, and 16% (9-26%) had probable RBP. Fifty percent (31-69%) had affection of the entire plexus, 18% (7-35%) of the upper trunk only, and 4% (1-18%) of the lower trunk. In 28% (14-48%) of cases assessment of a definite level was not possible. RBP was more common after radiotherapy and chemotherapy (42%) than after radiotherapy alone (26%) but the difference was not statistically significant (p = 0.10). The incidence of definite RBP was significantly higher in the younger age group (p = 0.02). This could be due to more extensive axillary surgery but also to the fact that chemotherapy was given to most premenopausal patients. In most patients with RBP the symptoms began during or immediately after radiotherapy, and were thus without significant latency. Chemotherapy might enhance the radiation-induced effect on nerve tissue, thus diminishing the latency period. Lymphedema was present in 22% (14-32%), especially in the older patients, and not associated with the development of RBP. In conclusion, the damaging effect of RT on peripheral nerve tissue was documented. Since no successful treatment is available, restricted use of RT to the brachial plexus is warranted, especially when administered concomitantly with cytotoxic therapy. (orig.).

  3. Coordination of Breast Cancer Care Between Radiation Oncologists and Surgeons: A Survey Study

    International Nuclear Information System (INIS)

    Jagsi, Reshma; Abrahamse, Paul; Morrow, Monica; Hamilton, Ann S.; Graff, John J.; Katz, Steven J.

    2012-01-01

    Purpose: To assess whether radiation oncologists and surgeons differ in their attitudes regarding the local management of breast cancer, and to examine coordination of care between these specialists. Methods and Materials: We surveyed attending surgeons and radiation oncologists who treated a population-based sample of patients diagnosed with breast cancer in metropolitan Detroit and Los Angeles. We identified 419 surgeons, of whom 318 (76%) responded, and 160 radiation oncologists, of whom 117 (73%) responded. We assessed demographic, professional, and practice characteristics; challenges to coordinated care; and attitudes toward management in three scenarios. Results: 92.1% of surgeons and 94.8% of radiation oncologists indicated access to a multidisciplinary tumor board. Nevertheless, the most commonly identified challenge to radiation oncologists, cited by 27.9%, was failure of other providers to include them in the treatment decision process early enough. Nearly half the surgeons (49.7%) stated that few or almost none of the breast cancer patients they saw in the past 12 months had consulted with a radiation oncologist before undergoing definitive surgery. Surgeons and radiation oncologists differed in their recommendations in management scenarios. Radiation oncologists were more likely to favor radiation than were surgeons for a patient with 3/20 lymph nodes undergoing mastectomy (p = 0.03); surgeons were more likely to favor more widely clear margins after breast conservation than were radiation oncologists (p = 0.001). Conclusions: Despite the widespread availability of tumor boards, a substantial minority of radiation oncologists indicated other providers failed to include them in the breast cancer treatment decision-making process early enough. Earlier inclusion of radiation oncologists may influence patient decisions, and interventions to facilitate this should be considered.

  4. Coordination of Breast Cancer Care Between Radiation Oncologists and Surgeons: A Survey Study

    Energy Technology Data Exchange (ETDEWEB)

    Jagsi, Reshma, E-mail: rjagsi@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Abrahamse, Paul [Department of Internal Medicine, University of Michigan, Ann Arbor, MI (United States); Morrow, Monica [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Hamilton, Ann S. [Keck School of Medicine, University of Southern California/Norris Comprehensive Cancer Center, Los Angeles, CA (United States); Graff, John J. [Department of Radiation Oncology, Cancer Institute of New Jersey, Robert Wood Johnson Medical School, New Brunswick, NJ (United States); Katz, Steven J. [Department of Internal Medicine, Division of General Medicine and Department of Health Management and Policy, School of Public Health, University of Michigan Health System, Ann Arbor, MI (United States)

    2012-04-01

    Purpose: To assess whether radiation oncologists and surgeons differ in their attitudes regarding the local management of breast cancer, and to examine coordination of care between these specialists. Methods and Materials: We surveyed attending surgeons and radiation oncologists who treated a population-based sample of patients diagnosed with breast cancer in metropolitan Detroit and Los Angeles. We identified 419 surgeons, of whom 318 (76%) responded, and 160 radiation oncologists, of whom 117 (73%) responded. We assessed demographic, professional, and practice characteristics; challenges to coordinated care; and attitudes toward management in three scenarios. Results: 92.1% of surgeons and 94.8% of radiation oncologists indicated access to a multidisciplinary tumor board. Nevertheless, the most commonly identified challenge to radiation oncologists, cited by 27.9%, was failure of other providers to include them in the treatment decision process early enough. Nearly half the surgeons (49.7%) stated that few or almost none of the breast cancer patients they saw in the past 12 months had consulted with a radiation oncologist before undergoing definitive surgery. Surgeons and radiation oncologists differed in their recommendations in management scenarios. Radiation oncologists were more likely to favor radiation than were surgeons for a patient with 3/20 lymph nodes undergoing mastectomy (p = 0.03); surgeons were more likely to favor more widely clear margins after breast conservation than were radiation oncologists (p = 0.001). Conclusions: Despite the widespread availability of tumor boards, a substantial minority of radiation oncologists indicated other providers failed to include them in the breast cancer treatment decision-making process early enough. Earlier inclusion of radiation oncologists may influence patient decisions, and interventions to facilitate this should be considered.

  5. Cosmetic Outcome and Seroma Formation After Breast-Conserving Surgery With Intraoperative Radiation Therapy Boost for Early Breast Cancer

    International Nuclear Information System (INIS)

    Senthi, Sashendra; Link, Emma; Chua, Boon H.

    2012-01-01

    Purpose: To evaluate cosmetic outcome and its association with breast wound seroma after breast-conserving surgery (BCS) with targeted intraoperative radiation therapy (tIORT) boost for early breast cancer. Methods and Materials: An analysis of a single-arm prospective study of 55 patients with early breast cancer treated with BCS and tIORT boost followed by conventional whole breast radiation therapy (WBRT) between August 2003 and January 2006 was performed. A seroma was defined as a fluid collection at the primary tumor resection site identified clinically or radiologically. Cosmetic assessments using the European Organization for Research and Treatment of Cancer rating system were performed at baseline before BCS and 30 months after WBRT was completed. Results: Twenty-eight patients (51%) developed a seroma, with 18 patients (33%) requiring at least 1 aspiration. Tumor location was significantly associated with seroma formation (P=.001). Ten of 11 patients with an upper inner quadrant tumor developed a seroma. Excellent or good overall cosmetic outcome at 30 months was observed in 34 patients (62%, 95% confidence interval 53%-80%). Seroma formation was not associated with the overall cosmetic result (P=.54). Conclusion: BCS with tIORT boost followed by WBRT was associated with an acceptable cosmetic outcome. Seroma formation was not significantly associated with an adverse cosmetic outcome.

  6. Correlation of breast recurrence (inflammatory type or not) after breast conserving surgery with radiation therapy and clinicopathological factors in breast cancer

    International Nuclear Information System (INIS)

    Nishimura, Reiki; Koyama, Hiroki

    1998-01-01

    To clarify risk factors for breast recurrence of inflammatory type after breast conserving therapy, we examined clinicopathological findings and therapies given after initial surgery. Nine cases of inflammatory breast recurrence out of 133 recurrent cases collected from a collaborative group supported by a grant-in-aid for Cancer Research by Japanese Ministry of Health and Welfare (7-24, Chairman: H. Koyama) were analyzed by a case control study. And forty-three recurrent cases in Kumamoto City Hospital were also analyzed similarly. Inflammatory breast recurrence after breast conserving surgery is characterized as follows: Most cases have negative surgical margin and may be unresponsive to radiation therapy, unlike non-inflammatory breast recurrence. Lymph node metastasis is involved in recurrence, but the difference in patients with only distant metastasis was positive lymphatic invasion. Distant metastasis coexisted at the time of recurrence, and secondary surgery was impossible in most cases. The prognosis after recurrence was unfavorable. These findings suggest that inflammatory recurrence is manifestation of so-called ''occult'' inflammatory breast cancer. (author)

  7. Correlation of breast recurrence (inflammatory type or not) after breast conserving surgery with radiation therapy and clinicopathological factors in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Reiki [Kumamoto City Hospital (Japan); Koyama, Hiroki

    1998-09-01

    To clarify risk factors for breast recurrence of inflammatory type after breast conserving therapy, we examined clinicopathological findings and therapies given after initial surgery. Nine cases of inflammatory breast recurrence out of 133 recurrent cases collected from a collaborative group supported by a grant-in-aid for Cancer Research by Japanese Ministry of Health and Welfare (7-24, Chairman: H. Koyama) were analyzed by a case control study. And forty-three recurrent cases in Kumamoto City Hospital were also analyzed similarly. Inflammatory breast recurrence after breast conserving surgery is characterized as follows: Most cases have negative surgical margin and may be unresponsive to radiation therapy, unlike non-inflammatory breast recurrence. Lymph node metastasis is involved in recurrence, but the difference in patients with only distant metastasis was positive lymphatic invasion. Distant metastasis coexisted at the time of recurrence, and secondary surgery was impossible in most cases. The prognosis after recurrence was unfavorable. These findings suggest that inflammatory recurrence is manifestation of so-called ``occult`` inflammatory breast cancer. (author)

  8. Lack of Prognostic Impact of Adjuvant Radiation on Oncologic Outcomes in Elderly Women with Breast Cancer.

    Science.gov (United States)

    Omidvari, Shapour; Talei, Abdolrasoul; Tahmasebi, Sedigheh; Moaddabshoar, Leila; Dayani, Maliheh; Mosalaei, Ahmad; Ahmadloo, Niloofar; Ansari, Mansour; Mohammadianpanah, Mohammad

    2015-01-01

    Radiotherapy plays an important role as adjuvant treatment in locally advanced breast cancer and in those patients who have undergone breast-conserving surgery. This study aimed to investigate the prognostic impact of adjuvant radiation on oncologic outcomes in elderly women with breast cancer. In this retrospective study, we reviewed and analyzed the characteristics, treatment outcome and survival of elderly women (aged ≥ 60 years) with breast cancer who were treated and followed-up between 1993 and 2014. The median follow up for the surviving patients was 38 (range 3-207) months. One hundred and seventy-eight patients with a median age of 74 (range 60-95) years were enrolled in the study. Of the total, 60 patients received postoperative adjuvant radiation (radiation group) and the remaining 118 did not (control group). Patients in the radiation group were significantly younger than those in the control group (P value=0.004). In addition, patients in radiation group had higher node stage (P value<0.001) and disease stage (P=0.003) and tended to have higher tumor grade (P=0.031) and received more frequent (P value <0.001) adjuvant and neoadjuvant chemotherapy compared to those in the control group. There was no statistically significant difference between two groups regarding the local control, disease-free survival and overall survival rates. In this study, we did not find a prognostic impact for adjuvant radiation on oncologic outcomes in elderly women with breast cancer.

  9. Radiation therapy for unresectable locally advanced breast cancer

    International Nuclear Information System (INIS)

    Horikawa, Noriko; Inoue, Masayoshi; Uehara, Tomoko; Miyasaka, T.; Miyasaka, M.; Tabata, Yoji; Sakamoto, Nobuyuki; Nakagawa, Y.

    2013-01-01

    Thirteen cases of inoperable advanced breast cancer were treated with radiotherapy between 2002 to 2012 at Nara Prefectural Hospital. All cases were treated by radiotherapy and chemo-endocrine therapy. Patients received 60-81 Gy (median 60 Gy) to the primary breast tumor. Response of the breast tumors were complete response in 3 cases (23%), partial response in 8 cases (62%) and stable disease in 2 cases (15%) (response rate: 85%). All breast tumors had been controlled and skin troubles were reduced. Radiotherapy for breast cancer is useful for primary tumor control and improved quality of life (QOL). Radiotherapy should be considered to be useful modality in the treatment of advanced breast cancer. (author)

  10. Surgeons' Knowledge and Practices Regarding the Role of Radiation Therapy in Breast Cancer Management

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jessica [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Hawley, Sarah T.; Zikmund-Fisher, Brian J. [Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Janz, Nancy K. [Department of Health Behavior and Health Education, University of Michigan School of Public Health, Ann Arbor, Michigan (United States); Sabel, Michael S. [Department of Surgery, University of Michigan, Ann Arbor, Michigan (United States); Katz, Steven J. [Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Jagsi, Reshma, E-mail: rjagsi@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-12-01

    Purpose: Population-based studies suggest underuse of radiation therapy, especially after mastectomy. Because radiation oncology is a referral-based specialty, knowledge and attitudes of upstream providers, specifically surgeons, may influence patients' decisions regarding radiation, including whether it is even considered. Therefore, we sought to evaluate surgeons' knowledge of pertinent risk information, their patterns of referral, and the correlates of surgeon knowledge and referral in specific breast cancer scenarios. Methods and Materials: We surveyed a national sample of 750 surgeons, with a 67% response rate. We analyzed responses from those who had seen at least 1 breast cancer patient in the past year (n=403), using logistic regression models to identify correlates of knowledge and appropriate referral. Results: Overall, 87% of respondents were general surgeons, and 64% saw >10 breast cancer patients in the previous year. In a scenario involving a 45-year-old undergoing lumpectomy, only 45% correctly estimated the risk of locoregional recurrence without radiation therapy, but 97% would refer to radiation oncology. In a patient with 2 of 20 nodes involved after mastectomy, 30% would neither refer to radiation oncology nor provide accurate information to make radiation decisions. In a patient with 4 of 20 nodes involved after mastectomy, 9% would not refer to radiation oncology. Fewer than half knew that the Oxford meta-analysis revealed a survival benefit from radiation therapy after lumpectomy (45%) or mastectomy (32%). Only 16% passed a 7-item knowledge test; female and more-experienced surgeons were more likely to pass. Factors significantly associated with appropriate referral to radiation oncology included breast cancer volume, tumor board participation, and knowledge. Conclusions: Many surgeons have inadequate knowledge regarding the role of radiation in breast cancer management, especially after mastectomy. Targeted educational

  11. TU-F-18C-03: X-Ray Scatter Correction in Breast CT: Advances and Patient Testing

    International Nuclear Information System (INIS)

    Ramamurthy, S; Sechopoulos, I

    2014-01-01

    Purpose: To further develop and perform patient testing of an x-ray scatter correction algorithm for dedicated breast computed tomography (BCT). Methods: A previously proposed algorithm for x-ray scatter signal reduction in BCT imaging was modified and tested with a phantom and on patients. A wireless electronic positioner system was designed and added to the BCT system that positions a tungsten plate in and out of the x-ray beam. The interpolation used by the algorithm was replaced with a radial basis function-based algorithm, with automated exclusion of non-valid sampled points due to patient motion or other factors. A 3D adaptive noise reduction filter was also introduced to reduce the impact of scatter quantum noise post-reconstruction. The impact on image quality of the improved algorithm was evaluated using a breast phantom and seven patient breasts, using quantitative metrics such signal difference (SD) and signal difference-to-noise ratios (SDNR) and qualitatively using image profiles. Results: The improvements in the algorithm resulted in a more robust interpolation step, with no introduction of image artifacts, especially at the imaged object boundaries, which was an issue in the previous implementation. Qualitative evaluation of the reconstructed slices and corresponding profiles show excellent homogeneity of both the background and the higher density features throughout the whole imaged object, as well as increased accuracy in the Hounsfield Units (HU) values of the tissues. Profiles also demonstrate substantial increase in both SD and SDNR between glandular and adipose regions compared to both the uncorrected and system-corrected images. Conclusion: The improved scatter correction algorithm can be reliably used during patient BCT acquisitions with no introduction of artifacts, resulting in substantial improvement in image quality. Its impact on actual clinical performance needs to be evaluated in the future. Research Agreement, Koning Corp., Hologic

  12. Acute radiation dermatitis and pneumonitis in Japanese breast cancer patients with whole breast hypofractionated radiotherapy compared to conventional radiotherapy

    International Nuclear Information System (INIS)

    Osako, Tomo; Oguchi, Masahiko; Kumada, Madoka; Nemoto, Keiko; Iwase, Takuji; Yamashita, Takashi

    2008-01-01

    The objective of this study was to evaluate acute morbidity, radiation dermatitis and pneumonitis, of Japanese patients treated with whole breast hypofractionated radiotherapy (RT) after breast-conserving surgery (BCS), compared to conventional RT. Japanese patients who received whole breast RT after BCS between October 2003 and September 2006 were retrospectively reviewed. Patients who had selected the conventional or hypofractionated schedule received whole breast irradiation of 50 Gy in 25 fractions plus boost or 40 Gy in 16 fractions plus boost. Radiation dermatitis and symptomatic pneumonitis were graded according to the Common Terminology Criteria for Adverse Events version 3.0. Of 443 consecutive patients, 377 (85%) received the conventional schedule and 66 (15%) received the hypofractionated schedule. Of patients treated with the conventional schedule, Grade 0, 1, 2 and 3 radiation dermatitis were observed in 16 (4%), 278 (74%), 77 (20%) and 6 (2%), respectively. Of patients treated with the hypofractionated schedule, Grade 0, 1, 2 and 3 dermatitis were observed in 11 (17%), 49 (74%), 5 (8%) and 1 (1%), respectively. Grade 2-3 dermatitis by the hypofractionated schedule (9%) was observed less frequently than that by the conventional schedule (22%) (chi-square test; P=0.016). Moreover, of patients treated with the conventional schedule, 4 (1%) had Grade 2 radiation pneumonitis. No patient treated with the hypofractionated schedule had symptomatic pneumonitis. Radiation dermatitis and pneumonitis in Japanese patients treated with the hypofractionated schedule is acceptable. Especially, radiation dermatitis by the hypofractionated schedule is milder than that by the conventional schedule. (author)

  13. Reduction of the scatter dose to the testicle outside the radiation treatment fields

    International Nuclear Information System (INIS)

    Kubo, H.; Shipley, W.U.

    1982-01-01

    A technique is described to reduce the dose to the contralateral testicle of patients with testis tumors during retroperitoneal therapy with 10 MV X-rays. When a conventional clam-shell shielding device was used, the dose to the testis from the photons scattered by the patient and the collimator jaws was found to be about 1.6% of the prescribed midplane dose. A more substantial gonadal shield made of low melting Ostalloy, that reduced further the dose from internal scattered X rays, was therefore designed. A 10 cm thick lead scrotal block above the scrotum immediately outside the field is shown to reduce the external scattered radiation to negligible levels. Using the shield and the block, it is possible to reduce the dose to the testicle to one-tenth of one percent of the prescribed midplane dose

  14. Reduction of the scatter dose to the testicle outside the radiation treatment fields

    International Nuclear Information System (INIS)

    Kubo, H.; Shipley, W.U.

    1982-01-01

    A technique is described to reduce the dose to the contralateral testicle of patients with testis tumors during retroperitoneal therapy with 10 MV X rays. When a conventional clam-shell shielding device was used, the dose to the testis from the photons scattered by the patient and collimator jaws was found to be about 1.6% of the prescribed midplane dose. A more substantial gonadal shield made of low melting point Ostalloy, that reduced further the dose from internal scattered X rays, was therefore designed. A 10 cm thick lead scrotal block above the scrotum immediately outside the field is shown to reduce the external scattering radiation to negligible levels. Using the shield and the block, it is possible to reduce the dose to the testicle to one-tenth of one percent of the prescribed midplane dose

  15. A successive order of scattering model for solving vector radiative transfer in the atmosphere

    International Nuclear Information System (INIS)

    Min Qilong; Duan Minzheng

    2004-01-01

    A full vector radiative transfer model for vertically inhomogeneous plane-parallel media has been developed by using the successive order of scattering approach. In this model, a fast analytical expansion of Fourier decomposition is implemented and an exponent-linear assumption is used for vertical integration. An analytic angular interpolation method of post-processing source function is also implemented to accurately interpolate the Stokes vector at arbitrary angles for a given solution. It has been tested against the benchmarks for the case of randomly orientated oblate spheroids, illustrating a good agreement for each stokes vector (within 0.01%). Sensitivity tests have been conducted to illustrate the accuracy of vertical integration and angle interpolation approaches. The contribution of each scattering order for different optical depths and single scattering albedos are also analyzed

  16. Evaluation of long-term cosmetic results and complications following breast conserving surgery and radiation therapy for breast cancer

    International Nuclear Information System (INIS)

    Fujishiro, Satsuki; Mitsumori, Michihide; Kokubo, Masaki; Nagata, Yasushi; Sasai, Keisuke; Hiraoka, Masahiro; Kodama, Hiroshi

    1999-01-01

    Long-term cosmetic outcomes and complications were evaluated in 109 patients with breast cancer who had been treated by breast conservation therapy. Patients received radiation therapy at Kyoto University Hospital following quadrantectomy and level II or III axillary node dissection. Factors that might influence long-term cosmetic results were also analyzed. Irradiation to the breast was administered in 2 Gy fractions, 5 times a week for a total of 50 Gy in all patients. Cobalt-60 γ-rays were used in 108 patients with the exception of 1 patient who received 6 Mev X-ray. Some patients with positive or close margins received boost irradiation of 10 Gy using electron beams to the primary tumor bed. Cosmetic outcome was assessed by both a scoring method and breast retraction assessment (BRA). Forty-seven percent of patients were assessed as excellent to good before radiation therapy. The percent of excellent to good decreased shortly after termination of radiation therapy, but gradually improved and stabilized by 3 years. Seventy percent of patients showed a score of excellent to good 5 years after treatment. The average BRA of the 109 patients was 3.0 cm. This did not change between 3 and 5 years after treatment. A significant correlation between cosmetic score and BRA was shown at all follow-up times. Factors such as age over 50 years (p=0.008), tumor location in the outer quadrant (p=0.02) and boost irradiation (p=0.03) significantly affected the cosmetic score. Arm edema and restriction of shoulder movement were observed in 22% and 49% at the start of radiation therapy, these improved within approximately 3 years and 1 year after treatment, respectively. Mild skin change was observed in 60% of patients even 5 years after treatment. The results indicate that cosmetic outcome after breast conservation therapy is clinically acceptable, and the complication rate is low. (author)

  17. A genomic copy number signature predicts radiation exposure in post-Chernobyl breast cancer.

    Science.gov (United States)

    Wilke, Christina M; Braselmann, Herbert; Hess, Julia; Klymenko, Sergiy V; Chumak, Vadim V; Zakhartseva, Liubov M; Bakhanova, Elena V; Walch, Axel K; Selmansberger, Martin; Samaga, Daniel; Weber, Peter; Schneider, Ludmila; Fend, Falko; Bösmüller, Hans C; Zitzelsberger, Horst; Unger, Kristian

    2018-04-16

    Breast cancer is the second leading cause of cancer death among women worldwide and besides life style, age and genetic risk factors, exposure to ionizing radiation is known to increase the risk for breast cancer. Further, DNA copy number alterations (CNAs), which can result from radiation-induced double-strand breaks, are frequently occurring in breast cancer cells. We set out to identify a signature of CNAs discriminating breast cancers from radiation-exposed and non-exposed female patients. We analyzed resected breast cancer tissues from 68 exposed female Chernobyl clean-up workers and evacuees and 68 matched non-exposed control patients for CNAs by array comparative genomic hybridization analysis (aCGH). Using a stepwise forward-backward selection approach a non-complex CNA signature, that is, less than ten features, was identified in the training data set, which could be subsequently validated in the validation data set (p value < 0.05). The signature consisted of nine copy number regions located on chromosomal bands 7q11.22-11.23, 7q21.3, 16q24.3, 17q21.31, 20p11.23-11.21, 1p21.1, 2q35, 2q35, 6p22.2. The signature was independent of any clinical characteristics of the patients. In all, we identified a CNA signature that has the potential to allow identification of radiation-associated breast cancer at the individual level. © 2018 UICC.

  18. Four-Week Course of Radiation for Breast Cancer Using Hypofractionated Intensity Modulated Radiation Therapy With an Incorporated Boost

    International Nuclear Information System (INIS)

    Freedman, Gary M.; Anderson, Penny R.; Goldstein, Lori J.; Ma Changming; Li Jinsheng; Swaby, Ramona F.; Litwin, Samuel; Watkins-Bruner, Deborah; Sigurdson, Elin R.; Morrow, Monica

    2007-01-01

    Purpose: Standard radiation for early breast cancer requires daily treatment for 6 to 7 weeks. This is an inconvenience to many women, and for some a barrier for breast conservation. We present the acute toxicity of a 4-week course of hypofractionated radiation. Methods and Materials: A total of 75 patients completed radiation on a Phase II trial approved by the hospital institutional review board. Eligibility criteria were broad to include any patient normally eligible for standard radiation: age ≥18 years, invasive or in situ cancer, American Joint Committee on Cancer Stage 0 to II, breast-conserving surgery, and any systemic therapy not given concurrently. The median age was 52 years (range, 31-81 years). Of the patients, 15% had ductal carcinoma in situ, 67% T1, and 19% T2; 71% were N0, 17% N1, and 12% NX. Chemotherapy was given before radiation in 44%. Using photon intensity-modulated radiation therapy and incorporated electron beam boost, the whole breast received 45 Gy and the lumpectomy bed 56 Gy in 20 treatments over 4 weeks. Results: The maximum acute skin toxicity by the end of treatment was Grade 0 in 9 patients (12%), Grade 1 in 49 (65%) and Grade 2 in 17 (23%). There was no Grade 3 or higher skin toxicity. After radiation, all Grade 2 toxicity had resolved by 6 weeks. Hematologic toxicity was Grade 0 in most patients except for Grade 1 neutropenia in 2 patients, and Grade 1 anemia in 11 patients. There were no significant differences in baseline vs. 6-week posttreatment patient-reported or physician-reported cosmetic scores. Conclusions: This 4-week course of postoperative radiation using intensity-modulated radiation therapy is feasible and is associated with acceptable acute skin toxicity and quality of life. Long-term follow-up data are needed. This radiation schedule may represent an alternative both to longer 6-week to 7-week standard whole-breast radiation and more radically shortened 1-week, partial-breast treatment schedules

  19. Prediction of mass absorption coefficients from inelastically scattered X-radiation for specimens of less than 'infinite thickness'

    International Nuclear Information System (INIS)

    Kieser, R.; Mulligan, T.J.

    1979-01-01

    An equation is developed which describes the X-ray scatter radiation from specimens of any thickness. This equation suggests that a specimen's mass absorption coefficient can be determined from its inelastically scattered X-radiation not only when the specimen is 'infinitely thick' but also when it is of 'intermediate thickness'. Measurements have been carried out with a standard energy-dispersive X-ray spectrometer on specimens of 'intermediate thickness'. Good agreement is obtained between the mass absorption coefficients that are calculated from the scattered radiation and those obtained on the basis of tabulated mass absorption coefficients for the elements. (author)

  20. Influence of multiple scattering of a relativistic electron in a periodic layered medium on coherent X-ray radiation

    Energy Technology Data Exchange (ETDEWEB)

    Blazhevich, S. V.; Kos’kova, T. V.; Noskov, A. V., E-mail: noskovbupk@mail.ru [Belgorod State National Research University (Russian Federation)

    2016-01-15

    A dynamic theory of coherent X-ray radiation generated in a periodic layered medium by a relativistic electron multiply scattered by target atoms has been developed. The expressions describing the spectral–angular characteristics of parametric X-ray radiation and diffracted transition radiation are derived. Numerical calculations based on the derived expressions have been performed.

  1. Nuclear resonant scattering of synchrotron radiation: Applications in magnetism of layered structures

    International Nuclear Information System (INIS)

    Schlage, Kai; Röhlsberger, Ralf

    2013-01-01

    Highlights: •Depth-resolved determination of magnetic spin structures. •Isotopic probe layers allow for probing selected depths in the sample. •High sensitivity to magnetic domain patterns via diffuse scattering. -- Abstract: Nuclear resonant scattering of synchrotron radiation has become an established tool within condensed-matter research. Synchrotron radiation with its outstanding brilliance, transverse coherence and polarization has opened this field for many unique studies, for fundamental research in the field of light-matter interaction as well as for materials science. This applies in particular for the electronic and magnetic structure of very small sample volumes like micro- and nano-structures and samples under extreme conditions of temperature and pressure. This article is devoted to the application of the technique to nanomagnetic systems such as thin films and multilayers. After a basic introduction into the method, a number of our experiments are presented to illustrate how magnetic spin structures within such layer systems can be revealed

  2. Radiation and scattering by cavity-backed antennas on a circular cylinder

    Science.gov (United States)

    Kempel, Leo C.; Volakis, John L.

    1993-01-01

    Conformal arrays are popular antennas for aircraft and missile platforms due to their inherent low weight and drag properties. However, to date there has been a dearth of rigorous analytical or numerical solutions to aid the designer. In fact, it has been common practice to use limited measurements and planar approximations in designing such non-planar antennas. The finite element-boundary integral method is extended to scattering and radiation by cavity-backed structures in an infinite, metallic cylinder. In particular, the formulation specifics such as weight functions, dyadic Green's function, implementation details, and particular difficulties inherent to cylindrical structures are discussed. Special care is taken to ensure that the resulting computer program has low memory demand and minimal computational requirements. Both scattering and radiation parameters are computed and validated as much as possible.

  3. Quantum theory of laser radiation scattering by electrons in magnetic fields

    International Nuclear Information System (INIS)

    Rochlin, H.; Davidovich, L.

    1982-01-01

    A system consisting of an electron in a static magnetic field, interacting with the quantized electromagnetic field, within the non-relativistic and electric dipole approximations (with a cutoff in momentum space) is considered. The Heisenberg equations of motion are solved exactly and the time evolution of the electric field is determined. The power spectrum of the scattered radiation is calculated, when the electromagnetic field is initially in a coherent state. The results for the line shape of the scattered radiation are shown to be valid for magnetic fields up to 10 12 G. The quantization of the electromagnetic field allows one to consider effects of the natural linewidth and its dependence on the magnetic field. The renormalization of the electron mass is included in these treatment, and the results remain finite when the cutoff goes to infinity. (Author) [pt

  4. Tailored long range forces on polarizable particles by collective scattering of broadband radiation

    International Nuclear Information System (INIS)

    Holzmann, D; Ritsch, H

    2016-01-01

    Collective coherent light scattering by polarizable particles creates surprisingly strong, long range inter-particle forces originating from interference of the light scattered by different particles. While for monochromatic laser beams this interaction decays with the inverse distance, we show here that in general the effective interaction range and geometry can be controlled by the illumination bandwidth and geometry. As generic example we study the modifications inter-particle forces within a 1D chain of atoms trapped in the field of a confined optical nanofiber mode. For two particles we find short range attraction as well as optical binding at multiple distances. The range of stable distances shrinks with increasing light bandwidth and for a very large bandwidth field as e.g. blackbody radiation. We find a strongly attractive potential up to a critical distance beyond which the force gets repulsive. Including multiple scattering can even lead to the appearance of a stable configuration at a large distance. Such broadband scattering forces should be observable contributions in ultra-cold atom interferometers or atomic clocks setups. They could be studied in detail in 1D geometries with ultra-cold atoms trapped along or within an optical nanofiber. Broadband radiation force interactions might also contribute in astrophysical scenarios as illuminated cold dust clouds. (paper)

  5. Magnetic x-ray scattering studies of holmium using synchro- tron radiation

    International Nuclear Information System (INIS)

    Gibbs, D.; Moncton, D.E.; D'Amico, K.L.; Bohr, J.; Grier, B.H.

    1985-01-01

    We present the results of magnetic x-ray scattering experiments on the rare-earth metal holmium using synchrotron radiation. Direct high-resolution measurements of the nominally incommensurate magnetic satellite reflections reveal new lock-in behavior which we explain within a simple spin-discommensuration model. As a result of magnetoelastic coupling, the spin-discommensuration array produces additional x-ray diffraction satellites. Their observation further substantiates the model and demonstrates additional advantages of synchrotron radiation for magnetic-structure studies

  6. Experimental study of TJ-1 plasma using scattering and radiation emission techniques

    International Nuclear Information System (INIS)

    Pardo, C.; Zurro, B.

    1987-01-01

    The Thomson scattering system of TJ-1 is described in detail. The radial profiles of Te and ne obtained in TJ-1 discharges are presented. This data make possible to deduce characteristic parameters of the plasma confinement in this machine, as energy confinement times, Zeff B. Using also radiation measurements (global and in the visible range) we obtained the particle confinement time and Zeff without non experimental assumptions. (Author) 52 refs

  7. Study of TJ-1 Tokamak plasmas with Thomson scattering and radiation diagnostics

    International Nuclear Information System (INIS)

    Pardo, C.; Zurro, B.

    1987-06-01

    The Thomson scattering system of TJ-1 is described in detail. The radial profiles of T e and n e obtained in TJ-1 discharges are presented. This data makes possible to deduce characteristic parameters of the plasma confinement in this machine, as energy confinement times, Z eff B. Using also radiation measurements (global and in the visible range) we obtained the particle confinement time and Z eff without non experimental assumptions. (author) 56 figs., 52 refs

  8. On the radiative corrections of deep inelastic scattering of muon neutrino on nucleon

    International Nuclear Information System (INIS)

    So Sang Guk

    1986-01-01

    The radiative corrections of deep inelastic scattering process VΜP→ ΜN are considered. Matrix element which takes Feynman one photon exchange diagrams into account at high transfer momentum are used. Based on calculation of the matrix element one can obtain matrix element for given process. It is shown that the effective cross section which takes one photon exchange into account is obtained. (author)

  9. Modeling and design of radiative hydrodynamic experiments with X-ray Thomson Scattering measurements on NIF

    Science.gov (United States)

    Ma, K. H.; Lefevre, H. J.; Belancourt, P. X.; MacDonald, M. J.; Doeppner, T.; Keiter, P. A.; Kuranz, C. C.; Johnsen, E.

    2017-10-01

    Recent experiments at the National Ignition Facility studied the effect of radiation on shock-driven hydrodynamic instability growth. X-ray radiography images from these experiments indicate that perturbation growth is lower in highly radiative shocks compared to shocks with negligible radiation flux. The reduction in instability growth is attributed to ablation from higher temperatures in the foam for highly radiative shocks. The proposed design implements the X-ray Thomson Scattering (XRTS) technique in the radiative shock tube platform to measure electron temperatures and densities in the shocked foam. We model these experiments with CRASH, an Eulerian radiation hydrodynamics code with block-adaptive mesh refinement, multi-group radiation transport and electron heat conduction. Simulations are presented with SiO2 and carbon foams for both the high temperature, radiative shock and the low-temperature, hydrodynamic shock cases. Calculations from CRASH give estimations for shock speed, electron temperature, effective ionization, and other quantities necessary for designing the XRTS diagnostic measurement. This work is funded by the LLNL under subcontract B614207, and was performed under the auspices of the U.S. DOE by LLNL under Contract No. DE-AC52-07NA27344.

  10. Prospective Study of Local Control and Late Radiation Toxicity After Intraoperative Radiation Therapy Boost for Early Breast Cancer

    International Nuclear Information System (INIS)

    Chang, David W.; Marvelde, Luc te; Chua, Boon H.

    2014-01-01

    Purpose: To report the local recurrence rate and late toxicity of intraoperative radiation therapy (IORT) boost to the tumor bed using the Intrabeam System followed by external-beam whole-breast irradiation (WBI) in women with early-stage breast cancer in a prospective single-institution study. Methods and Materials: Women with breast cancer ≤3 cm were recruited between February 2003 and May 2005. After breast-conserving surgery, a single dose of 5 Gy IORT boost was delivered using 50-kV x-rays to a depth of 10 mm from the applicator surface. This was followed by WBI to a total dose of 50 Gy in 25 fractions. Patients were reviewed at regular, predefined intervals. Late toxicities were recorded using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring systems. Results: Fifty-five patients completed both IORT boost and external-beam WBI. Median follow-up was 3.3 years (range, 1.4-4.1 years). There was no reported locoregional recurrence or death. One patient developed distant metastases. Grade 2 and 3 subcutaneous fibrosis was detected in 29 (53%) and 8 patients (15%), respectively. Conclusions: The use of IORT as a tumor bed boost using kV x-rays in breast-conserving therapy was associated with good local control but a clinically significant rate of grade 2 and 3 subcutaneous fibrosis

  11. Radiation therapy and patient age in the survival from early-stage breast cancer

    International Nuclear Information System (INIS)

    Joslyn, Sue A.

    1999-01-01

    Purpose: To analyze the use of radiation therapy following local excision of invasive localized breast cancer and subsequent survival by 5-year age category. Methods: Data for 27,399 women diagnosed with localized stage of breast cancer and treated with local excision surgery from 1983 through 1992 were collected and provided by the national Surveillance, Epidemiology, and End Results (SEER) program. Use of radiation therapy was analyzed by race, ethnic background, geographic location, and age at diagnosis. Survival for women treated with local excision plus radiation therapy was compared to that of women treated with local excision alone for each 5-year age category. Results: Subjects in older age groups were significantly less likely (p < 0.001) to receive radiation following local excision compared to younger age groups. Statistically significant survival advantages were conferred on women receiving radiation therapy in each 5-year age category from age 35 to 84 years (ranging from p = 0.02 to p < 0.0001). Conclusion: While the use of radiation therapy following local excision of early-stage breast tumors drops significantly in older age groups, women aged 35-84 years receiving radiation therapy had significant reductions in mortality. These results did not appear to be influenced by the presence of mortal comorbid conditions. These results strongly suggest the need to consider carefully patient characteristics other than age in deciding the course of treatment for early-stage breast cancer

  12. Classification of breast tissue using a laboratory system for small-angle x-ray scattering (SAXS)

    International Nuclear Information System (INIS)

    Sidhu, S; Siu, K K W; Falzon, G; Hart, S A; Fox, J G; Lewis, R A

    2011-01-01

    Structural changes in breast tissue at the nanometre scale have been shown to differentiate between tissue types using synchrotron SAXS techniques. Classification of breast tissues using information acquired from a laboratory SAXS camera source could possibly provide a means of adopting SAXS as a viable diagnostic procedure. Tissue samples were obtained from surgical waste from 66 patients and structural components of the tissues were examined between q = 0.25 and 2.3 nm -1 . Principal component analysis showed that the amplitude of the fifth-order axial Bragg peak, the magnitude of the integrated intensity and the full-width at half-maximum of the fat peak were significantly different between tissue types. A discriminant analysis showed that excellent classification can be achieved; however, only 30% of the tissue samples provided the 16 variables required for classification. This suggests that the presence of disease is represented by a combination of factors, rather than one specific trait. A closer examination of the amorphous scattering intensity showed not only a trend of increased scattering intensity with disease severity, but also a corresponding decrease in the size of the scatterers contributing to this intensity.

  13. Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Adam, L.-E.; Brix, G.

    1999-01-01

    The correction of scattered radiation is one of the most challenging tasks in 3D positron emission tomography (PET) and knowledge about the amount of scatter and its distribution is a prerequisite for performing an accurate correction. One concern in 3D PET in contrast to 2D PET is the scatter contribution from activity outside the field-of-view (FOV) and multiple scatter. Using Monte Carlo simulations, we examined the scatter distribution for various phantoms. The simulations were performed for a whole-body PET system (ECAT EXACT HR + , Siemens/CTI) with an axial FOV of 15.5 cm and a ring diameter of 82.7 cm. With (without) interplane septa, up to one (two) out of three detected events are scattered (for a centred point source in a water-filled cylinder that nearly fills out the patient port), whereby the relative scatter fraction varies significantly with the axial position. Our results show that for an accurate scatter correction, activity as well as scattering media outside the FOV have to be taken into account. Furthermore it could be shown that there is a considerable amount of multiple scatter which has a different spatial distribution from single scatter. This means that multiple scatter cannot be corrected by simply rescaling the single scatter component. (author)

  14. Computational Modeling of Micrometastatic Breast Cancer Radiation Dose Response

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Daniel L.; Debeb, Bisrat G. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Morgan Welch Inflammatory Breast Cancer Research Program and Clinic, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Thames, Howard D. [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Woodward, Wendy A., E-mail: wwoodward@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Morgan Welch Inflammatory Breast Cancer Research Program and Clinic, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-09-01

    Purpose: Prophylactic cranial irradiation (PCI) involves giving radiation to the entire brain with the goals of reducing the incidence of brain metastasis and improving overall survival. Experimentally, we have demonstrated that PCI prevents brain metastases in a breast cancer mouse model. We developed a computational model to expand on and aid in the interpretation of our experimental results. Methods and Materials: MATLAB was used to develop a computational model of brain metastasis and PCI in mice. Model input parameters were optimized such that the model output would match the experimental number of metastases per mouse from the unirradiated group. An independent in vivo–limiting dilution experiment was performed to validate the model. The effect of whole brain irradiation at different measurement points after tumor cells were injected was evaluated in terms of the incidence, number of metastases, and tumor burden and was then compared with the corresponding experimental data. Results: In the optimized model, the correlation between the number of metastases per mouse and the experimental fits was >95. Our attempt to validate the model with a limiting dilution assay produced 99.9% correlation with respect to the incidence of metastases. The model accurately predicted the effect of whole-brain irradiation given 3 weeks after cell injection but substantially underestimated its effect when delivered 5 days after cell injection. The model further demonstrated that delaying whole-brain irradiation until the development of gross disease introduces a dose threshold that must be reached before a reduction in incidence can be realized. Conclusions: Our computational model of mouse brain metastasis and PCI correlated strongly with our experiments with unirradiated mice. The results further suggest that early treatment of subclinical disease is more effective than irradiating established disease.

  15. Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield.

    Science.gov (United States)

    Politi, Luigi; Biondi-Zoccai, Giuseppe; Nocetti, Luca; Costi, Tiziana; Monopoli, Daniel; Rossi, Rosario; Sgura, Fabio; Modena, Maria Grazia; Sangiorgi, Giuseppe M

    2012-01-01

    Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans. Sixty consecutive patients undergoing coronary angiography by radial approach were randomized 1:1 to Radpad use versus no radiation shield protection. The sterile shield was placed around the area of right radial artery sheath insertion and extended medially to the patient trunk. All diagnostic procedures were performed by the same operator to reduce variability in radiation absorption. Radiation exposure was measured blindly using thermoluminescence dosimeters positioned at the operator's chest, left eye, left wrist, and thyroid. Despite similar fluoroscopy time (3.52 ± 2.71 min vs. 3.46 ± 2.77 min, P = 0.898) and total examination dose (50.5 ± 30.7 vs. 45.8 ± 18.0 Gycm(2), P = 0.231), the mean total radiation exposure to the operator was significantly lower when Radpad was utilized (282.8 ± 32.55 μSv vs. 367.8 ± 105.4 μSv, P Radpad utilization at all body locations ranging from 13 to 34% reduction. This first-in-men randomized trial demonstrates that Radpad significantly reduces occupational radiation exposure during coronary angiography performed through right radial artery access. Copyright © 2011 Wiley Periodicals, Inc.

  16. Scattering and absorption characteristics of aerosols at an urban megacity over IGB: Implications to radiative forcing

    Science.gov (United States)

    Srivastava, A. K.; Bisht, D. S.; Singh, Sachchidanand; Kishore, N.; Soni, V. K.; Singh, Siddhartha; Tiwari, S.

    2018-06-01

    Aerosol scattering and absorption characteristics were investigated at an urban megacity Delhi in the western Indo-Gangetic Basin (IGB) during the period from October 2011 to September 2012 using different in-situ measurements. The scattering coefficient (σsp at 550 nm) varied between 71 and 3014 Mm-1 (mean 710 ± 615 Mm-1) during the entire study period, which was about ten times higher than the absorption coefficient (σabs at 550 nm 67 ± 40 Mm-1). Seasonally, σsp and σabs were substantially higher during the winter/post-monsoon periods, which also gave rise to single scattering albedo (SSA) by 5%. The magnitude of SSA (at 550 nm) varied between 0.81 and 0.94 (mean: 0.89 ± 0.05). Further, the magnitude of scattering Ångström exponent (SAE) and back-scattering Ångström exponent (BAE) showed a wide range from -1.20 to 1.57 and -1.13 to 0.87, respectively which suggests large variability in aerosol sizes and emission sources. Relatively higher aerosol backscatter fraction (b at 550 nm) during the monsoon (0.25 ± 0.10) suggests more inhomogeneous scattering, associated with the coarser dust particles. However, lower value of b during winter (0.13 ± 0.02) is associated with more isotropic scattering due to dominance of smaller size particles. This is further confirmed with the estimated asymmetry parameter (AP at 550 nm), which exhibits opposite trend with b. The aerosol optical parameters were used in a radiative transfer model to estimate aerosol radiative forcing. A mean radiative forcing of -61 ± 22 W m-2 (ranging from -111 to -40 W m-2) was observed at the surface and 42 ± 24 W m-2 (ranging from 18 to 87 W m-2) into the atmosphere, which can give rise to the mean atmospheric heating rate of 1.18 K day-1.

  17. Identification of human breast pathologies by X-ray elastic scattering; Identificacao de patologias mamarias atraves do espalhamento elastico de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Conceicao, Andre L.C.; Antoniassi, Marcelo; Poletti, Martin E., E-mail: andre_conceicao@yahoo.com.b [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2011-07-01

    In this paper we determine the scattering profiles of normal, benign and malignant human breast samples in a momentum transfer range of 0.07nm{sup -1} {<=}q{<=}70.55nm{sup -1}, resulted from combining WAXS (wide angle x-ray scattering) and SAXS (small angle x-ray scattering) data. The results showed considerable differences between the scattering profiles of each tissue type. Based on this fact, some parameters, representing structural features, were extracted from these scattering profiles and submitted to a discriminant analysis. From statistical analysis, the ratio between the peak intensities at q=19.8nm{sup -1} and q=13.9nm{sup -1} and the intensity of third order axial collagen peak arose as two potentials breast tissue classifiers and, from combining them it was possible differentiate among normal, benign and malignant lesions. (author)

  18. Radiation dose, reproductive history, and breast cancer risk among Japanese A-bomb survivors

    International Nuclear Information System (INIS)

    Land, C.E.

    1992-01-01

    Excess risk of female breast cancer is among the most comprehensively documented late effects of exposure to substantial doses of ionizing radiation, based on studies of medically irradiated populations and the survivors of the A-bombings of Hiroshima and Nagasaki. This study looks at the interaction of dose with epidemiological factors like age at first full-term pregnancy and family history of breast cancer, most closely associated with risk in epidemiological studies of non-irradiatied populations. 1 fig., 2 tabs

  19. Post-mastectomy radiation in large node-negative breast tumors: Does size really matter?

    International Nuclear Information System (INIS)

    Floyd, Scott R.; Taghian, Alphonse G.

    2009-01-01

    Treatment decisions regarding local control can be particularly challenging for T3N0 breast tumors because of difficulty in estimating rates of local failure after mastectomy. Reports in the literature detailing the rates of local failure vary widely, likely owing to the uncommon incidence of this clinical situation. The literature regarding this clinical scenario is reviewed, including recent reports that specifically address the issue of local failure rates after mastectomy in the absence of radiation for large node-negative breast tumors.

  20. Cancer of the breast: induction by radiation and role of mammography

    Energy Technology Data Exchange (ETDEWEB)

    Simon, N

    1977-10-01

    Conflict in the management of cancer of the breast exists. Diagnosis by x-ray mammography provides early effective treatment, but x-ray exposure to the breast is cancerogenic. Prudence requires the use of low dose x-rays in mammography, and limits the use of x-ray mammography in the young. Guide lines for the indications for mammography are changing, and large scale population exposure to radiation should await results of demonstration projects in the United States.

  1. Rapid and sensitive phenotypic marker detection on breast cancer cells using surface-enhanced Raman scattering (SERS) imaging.

    Science.gov (United States)

    Lee, Sangyeop; Chon, Hyangah; Lee, Jiyoung; Ko, Juhui; Chung, Bong Hyun; Lim, Dong Woo; Choo, Jaebum

    2014-01-15

    We report a surface-enhanced Raman scattering (SERS)-based cellular imaging technique to detect and quantify breast cancer phenotypic markers expressed on cell surfaces. This technique involves the synthesis of SERS nano tags consisting of silica-encapsulated hollow gold nanospheres (SEHGNs) conjugated with specific antibodies. Hollow gold nanospheres (HGNs) enhance SERS signal intensity of individual particles by localizing surface electromagnetic fields through pinholes in the hollow particle structures. This capacity to enhance imaging at the level of single molecules permits the use of HGNs to detect specific biological markers expressed in living cancer cells. In addition, silica encapsulation greatly enhances the stability of nanoparticles. Here we applied a SERS-based imaging technique using SEHGNs in the multiplex imaging of three breast cancer cell phenotypes. Expression of epidermal growth factor (EGF), ErbB2, and insulin-like growth factor-1 (IGF-1) receptors were assessed in the MDA-MB-468, KPL4 and SK-BR-3 human breast cancer cell lines. SERS imaging technology described here can be used to test the phenotype of a cancer cell and quantify proteins expressed on the cell surface simultaneously. Based on results, this technique may enable an earlier diagnosis of breast cancer than is currently possible and offer guidance in treatment. © 2013 Elsevier B.V. All rights reserved.

  2. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  3. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  4. A simple property of the contribution of double scattered radiation to the lidar returnes from homogeneous fogs

    International Nuclear Information System (INIS)

    Bruscaglioni, P.

    1979-01-01

    By using the formulas presented in a previous paper for the calculation of the ratio D/S between the contributions of doubly scattered and singly scattered radiation to lidar returns from homogeneous fogs, it is shown that the ratio D/S is proportional to the lidar range, indipendently from the particular model of fog, i.e. from the assumed phase scattering function

  5. Multidisciplinary approach of early breast cancer: The biology applied to radiation oncology

    International Nuclear Information System (INIS)

    Bourgier, Céline; Ozsahin, Mahmut; Azria, David

    2010-01-01

    Early breast cancer treatment is based on a multimodality approach with the application of clinical and histological prognostic factors to determine locoregional and systemic treatments. The entire scientific community is strongly involved in the management of this disease: radiologists for screening and early diagnosis, gynecologists, surgical oncologists and radiation oncologists for locoregional treatment, pathologists and biologists for personalized characterization, genetic counselors for BRCA mutation history and medical oncologists for systemic therapies. Recently, new biological tools have established various prognostic subsets of breast cancer and developed predictive markers for miscellaneous treatments. The aim of this article is to highlight the contribution of biological tools in the locoregional management of early breast cancer

  6. Radiation therapy planning of a breast cancer patient with in situ pacemaker-challenges and lessons

    Energy Technology Data Exchange (ETDEWEB)

    Munshi, Anusheel; Wadasadawala, Tabassum; Budrukkar, Ashwini; Jalali, Rakesh; Dinshaw, Ketayun A [Dept. of Radiation Oncology, Tata Memorial Hospital, Mumbai (India); Sharma, Pramod Kumar; Sharma, Dayananda [Dept. of Radiation Physics, Tata Memorial Hospital, Mumbai (India)

    2008-02-15

    A postmenopausal lady with an in situ pacemaker developed a lump in the left breast and was diagnosed to have breast cancer. The patient underwent breast conservative surgery and was planned for post operative radiotherapy. The location of the tumor relative to the pacemaker provided a unique challenge in planning radiotherapy and the patient had an uneventful post radiotherapy course. A literature review revealed that modern generation pacemakers are very sensitive to radiation compared to their older counterparts. The present article makes suggestions towards reducing dose in radiotherapy planning in pacemaker patients

  7. Radiation therapy planning of a breast cancer patient with in situ pacemaker-challenges and lessons

    International Nuclear Information System (INIS)

    Munshi, Anusheel; Wadasadawala, Tabassum; Budrukkar, Ashwini; Jalali, Rakesh; Dinshaw, Ketayun A.; Sharma, Pramod Kumar; Sharma, Dayananda

    2008-01-01

    A postmenopausal lady with an in situ pacemaker developed a lump in the left breast and was diagnosed to have breast cancer. The patient underwent breast conservative surgery and was planned for post operative radiotherapy. The location of the tumor relative to the pacemaker provided a unique challenge in planning radiotherapy and the patient had an uneventful post radiotherapy course. A literature review revealed that modern generation pacemakers are very sensitive to radiation compared to their older counterparts. The present article makes suggestions towards reducing dose in radiotherapy planning in pacemaker patients

  8. Investigation of absorbed radiation dose in refraction-enhanced breast tomosynthesis by a Laue case analyser

    International Nuclear Information System (INIS)

    Sato, H.; Ando, M.; Shimao, D.

    2011-01-01

    An early diagnosis system for breast cancer using refraction-enhanced breast tomosynthesis is under development. Tomograms of breast specimens based on refraction-contrast were demonstrated using the simplest shift-and-add tomosynthesis algorithm. Raw projection image data of breast specimens for tomosynthesis were acquired for a total of 51 views over an angle of 50 deg., in increments of 1 deg., by rotating the object. The incident X ray was monochromatic synchrotron radiation with 20 keV. The purpose of this study was to estimate the absorbed dose of a new X-ray imaging method. As breast cancer almost always arises in glandular breast tissue, the average absorbed dose in such glandular tissue should be measured to estimate the radiation risk associated with mammography. The absorbed dose of the mammary gland due to monochromatic X rays was calculated by the Monte Carlo method, and the optimal X ray energy range for refraction-enhanced breast tomosynthesis was investigated through actual measurements. Compared with the conventional method, it was found to be below one-sixth per inspection. (authors)

  9. Quantitative proteomics reveals middle infrared radiation-interfered networks in breast cancer cells.

    Science.gov (United States)

    Chang, Hsin-Yi; Li, Ming-Hua; Huang, Tsui-Chin; Hsu, Chia-Lang; Tsai, Shang-Ru; Lee, Si-Chen; Huang, Hsuan-Cheng; Juan, Hsueh-Fen

    2015-02-06

    Breast cancer is one of the leading cancer-related causes of death worldwide. Treatment of triple-negative breast cancer (TNBC) is complex and challenging, especially when metastasis has developed. In this study, we applied infrared radiation as an alternative approach for the treatment of TNBC. We used middle infrared (MIR) with a wavelength range of 3-5 μm to irradiate breast cancer cells. MIR significantly inhibited cell proliferation in several breast cancer cells but did not affect the growth of normal breast epithelial cells. We performed iTRAQ-coupled LC-MS/MS analysis to investigate the MIR-triggered molecular mechanisms in breast cancer cells. A total of 1749 proteins were identified, quantified, and subjected to functional enrichment analysis. From the constructed functionally enriched network, we confirmed that MIR caused G2/M cell cycle arrest, remodeled the microtubule network to an astral pole arrangement, altered the actin filament formation and focal adhesion molecule localization, and reduced cell migration activity and invasion ability. Our results reveal the coordinative effects of MIR-regulated physiological responses in concentrated networks, demonstrating the potential implementation of infrared radiation in breast cancer therapy.

  10. TH-AB-209-11: Breast Microcalcification Classification Using Spectral X-Ray Coherent Scatter Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ghammraoui, B; M Popescu, L; Badano, A [Food & Drug Administration, Silver Spring, MD (United States)

    2016-06-15

    Purpose: To investigate the ability of Coherent Scatter Computed Tomography (CSCT) to distinguish non-invasively between type I calcifications, consisting of calcium oxalate dihydrate (CO) compounds which are more often associated with benign lesions, and type II calcifications containing hydroxyapatite (HA) which are predominantly associated with malignant tumors. Methods: The coherent scatter cross sections of HA and CO were measured using an energy dispersive x-ray diffractometer. The measured cross sections were introduced into MC-GPU Monte Carlo simulation code for studying the applicability of CSCT to discriminate between the two types of microcalcifications within the whole breast. Simulations were performed on a virtual phantom with inserted HA and CO spots of different sizes and placed in regions of interest having different background compositions. We considered a polychromatic x-ray source and an energy resolving photon counting detector. We applied an algorithm that estimates scatter components in projection space in order to obtain material-specific images of the breast. As material components adipose, glandular, HA and CO were used. The relative contrast of HA and CO components were used for type I and type II microcalcification discrimination. Results: The reconstructed CSCT images showed material-specific component-contrast values, with the highest CO or HA component contrast corresponding generally to the actual CO or HA feature, respectively. The discrimination performance varies with the x-ray intensity, calcification size, and background composition. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to unity. Conclusion: The simulation results obtained for a uniform breast imaging phantom indicate that CSCT has potential to be used as a non-invasive method for discrimination between type

  11. Evaluation of a scattered radiation field in a cluster relevant for multiple-energy X-ray holography

    International Nuclear Information System (INIS)

    Fonda, L.

    1996-09-01

    We analyze theoretically a recent proposal of utilizing synchrotron radiation to generate an electromagnetic scattering field at a specific target atom inside a material sample. The direct wave coming from a wiggler interferes there with the waves scattered by the surrounding atoms. The suggestion is relevant for obtaining atomic holographic images. (author). 23 refs, 2 figs

  12. A model-based approach of scatter dose contributions and efficiency of apron shielding for radiation protection in CT.

    Science.gov (United States)

    Weber, N; Monnin, P; Elandoy, C; Ding, S

    2015-12-01

    Given the contribution of scattered radiations to patient dose in CT, apron shielding is often used for radiation protection. In this study the efficiency of apron was assessed with a model-based approach of the contributions of the four scatter sources in CT, i.e. external scattered radiations from the tube and table, internal scatter from the patient and backscatter from the shielding. For this purpose, CTDI phantoms filled with thermoluminescent dosimeters were scanned without apron, and then with an apron at 0, 2.5 and 5 cm from the primary field. Scatter from the tube was measured separately in air. The scatter contributions were separated and mathematically modelled. The protective efficiency of the apron was low, only 1.5% in scatter dose reduction on average. The apron at 0 cm from the beam lowered the dose by 7.5% at the phantom bottom but increased the dose by 2% at the top (backscatter) and did not affect the centre. When the apron was placed at 2.5 or 5 cm, the results were intermediate to the one obtained with the shielding at 0 cm and without shielding. The apron effectiveness is finally limited to the small fraction of external scattered radiation. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Multiple scattering effects with cyclical terms in active remote sensing of vegetated surface using vector radiative transfer theory

    Science.gov (United States)

    The energy transport in a vegetated (corn) surface layer is examined by solving the vector radiative transfer equation using a numerical iterative approach. This approach allows a higher order that includes the multiple scattering effects. Multiple scattering effects are important when the optical t...

  14. Preoperative Single-Fraction Partial Breast Radiation Therapy: A Novel Phase 1, Dose-Escalation Protocol With Radiation Response Biomarkers

    International Nuclear Information System (INIS)

    Horton, Janet K.; Blitzblau, Rachel C.; Yoo, Sua; Geradts, Joseph; Chang, Zheng; Baker, Jay A.; Georgiade, Gregory S.; Chen, Wei; Siamakpour-Reihani, Sharareh; Wang, Chunhao; Broadwater, Gloria; Groth, Jeff; Palta, Manisha; Dewhirst, Mark; Barry, William T.; Duffy, Eileen A.

    2015-01-01

    Purpose: Women with biologically favorable early-stage breast cancer are increasingly treated with accelerated partial breast radiation (PBI). However, treatment-related morbidities have been linked to the large postoperative treatment volumes required for external beam PBI. Relative to external beam delivery, alternative PBI techniques require equipment that is not universally available. To address these issues, we designed a phase 1 trial utilizing widely available technology to 1) evaluate the safety of a single radiation treatment delivered preoperatively to the small-volume, intact breast tumor and 2) identify imaging and genomic markers of radiation response. Methods and Materials: Women aged ≥55 years with clinically node-negative, estrogen receptor–positive, and/or progesterone receptor–positive HER2−, T1 invasive carcinomas, or low- to intermediate-grade in situ disease ≤2 cm were enrolled (n=32). Intensity modulated radiation therapy was used to deliver 15 Gy (n=8), 18 Gy (n=8), or 21 Gy (n=16) to the tumor with a 1.5-cm margin. Lumpectomy was performed within 10 days. Paired pre- and postradiation magnetic resonance images and patient tumor samples were analyzed. Results: No dose-limiting toxicity was observed. At a median follow-up of 23 months, there have been no recurrences. Physician-rated cosmetic outcomes were good/excellent, and chronic toxicities were grade 1 to 2 (fibrosis, hyperpigmentation) in patients receiving preoperative radiation only. Evidence of dose-dependent changes in vascular permeability, cell density, and expression of genes regulating immunity and cell death were seen in response to radiation. Conclusions: Preoperative single-dose radiation therapy to intact breast tumors is well tolerated. Radiation response is marked by early indicators of cell death in this biologically favorable patient cohort. This study represents a first step toward a novel partial breast radiation approach. Preoperative radiation should

  15. Preoperative Single-Fraction Partial Breast Radiation Therapy: A Novel Phase 1, Dose-Escalation Protocol With Radiation Response Biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Horton, Janet K., E-mail: janet.horton@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Blitzblau, Rachel C.; Yoo, Sua [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Geradts, Joseph [Department of Pathology, Duke University Medical Center, Durham, North Carolina (United States); Chang, Zheng [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Baker, Jay A. [Department of Radiology, Duke University Medical Center, Durham, North Carolina (United States); Georgiade, Gregory S. [Department of Surgery, Duke University Medical Center, Durham, North Carolina (United States); Chen, Wei [Department of Bioinformatics: Duke Cancer Institute, Duke University Medical Center, Durham, North Carolina (United States); Siamakpour-Reihani, Sharareh; Wang, Chunhao [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Broadwater, Gloria [Department of Biostatistics: Duke Cancer Institute, Duke University Medical Center, Durham, North Carolina (United States); Groth, Jeff [Department of Pathology, Duke University Medical Center, Durham, North Carolina (United States); Palta, Manisha; Dewhirst, Mark [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Barry, William T. [Department of Biostatistics and Bioinformatics, Duke University Medical Center, Durham, North Carolina (United States); Biostatistics and Computational Biology, Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Duffy, Eileen A. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); and others

    2015-07-15

    Purpose: Women with biologically favorable early-stage breast cancer are increasingly treated with accelerated partial breast radiation (PBI). However, treatment-related morbidities have been linked to the large postoperative treatment volumes required for external beam PBI. Relative to external beam delivery, alternative PBI techniques require equipment that is not universally available. To address these issues, we designed a phase 1 trial utilizing widely available technology to 1) evaluate the safety of a single radiation treatment delivered preoperatively to the small-volume, intact breast tumor and 2) identify imaging and genomic markers of radiation response. Methods and Materials: Women aged ≥55 years with clinically node-negative, estrogen receptor–positive, and/or progesterone receptor–positive HER2−, T1 invasive carcinomas, or low- to intermediate-grade in situ disease ≤2 cm were enrolled (n=32). Intensity modulated radiation therapy was used to deliver 15 Gy (n=8), 18 Gy (n=8), or 21 Gy (n=16) to the tumor with a 1.5-cm margin. Lumpectomy was performed within 10 days. Paired pre- and postradiation magnetic resonance images and patient tumor samples were analyzed. Results: No dose-limiting toxicity was observed. At a median follow-up of 23 months, there have been no recurrences. Physician-rated cosmetic outcomes were good/excellent, and chronic toxicities were grade 1 to 2 (fibrosis, hyperpigmentation) in patients receiving preoperative radiation only. Evidence of dose-dependent changes in vascular permeability, cell density, and expression of genes regulating immunity and cell death were seen in response to radiation. Conclusions: Preoperative single-dose radiation therapy to intact breast tumors is well tolerated. Radiation response is marked by early indicators of cell death in this biologically favorable patient cohort. This study represents a first step toward a novel partial breast radiation approach. Preoperative radiation should

  16. Baryon scattering at high energies. Wave function, impact factor, and gluon radiation

    International Nuclear Information System (INIS)

    Bartels, J.; Motyka, L.; Jagellonian Univ., Krakow

    2007-11-01

    The scattering of a baryon consisting of three massive quarks is investigated in the high energy limit of perturbative QCD. A model of a relativistic proton-like wave function, dependent on valence quark longitudinal and transverse momenta and on quark helicities, is proposed, and we derive the baryon impact factors for two, three and four t-channel gluons. We find that the baryonic impact factor can be written as a sum of three pieces: in the first one a subsystem consisting of two of the three quarks behaves very much like the quark-antiquark pair in γ * scattering, whereas the third quark acts as a spectator. The second term belongs to the odderon, whereas in the third (C-even) piece all three quarks participate in the scattering. This term is new and has no analogue in γ * scattering. We also study the small x evolution of gluon radiation for each of these three terms. The first term follows the same pattern of gluon radiation as the γ * -initiated quark-antiquark dipole, and, in particular, it contains the BFKL evolution followed by the 2→4 transition vertex (triple Pomeron vertex). The odderon-term is described by the standard BKP evolution, and the baryon couples to both known odderon solutions, the Janik-Wosiek solution and the BLV solution. Finally, the t-channel evolution of the third term starts with a three reggeized gluon state which then, via a new 3→4 transition vertex, couples to the four gluon (two-Pomeron) state. We briefly discuss a few consequences of these findings, in particular the pattern of unitarization of high energy baryon scattering amplitudes. (orig.)

  17. Baryon scattering at high energies. Wave function, impact factor, and gluon radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bartels, J. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Motyka, L. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik]|[Jagellonian Univ., Krakow (Poland). Inst. of Physics

    2007-11-15

    The scattering of a baryon consisting of three massive quarks is investigated in the high energy limit of perturbative QCD. A model of a relativistic proton-like wave function, dependent on valence quark longitudinal and transverse momenta and on quark helicities, is proposed, and we derive the baryon impact factors for two, three and four t-channel gluons. We find that the baryonic impact factor can be written as a sum of three pieces: in the first one a subsystem consisting of two of the three quarks behaves very much like the quark-antiquark pair in {gamma}{sup *} scattering, whereas the third quark acts as a spectator. The second term belongs to the odderon, whereas in the third (C-even) piece all three quarks participate in the scattering. This term is new and has no analogue in {gamma}{sup *} scattering. We also study the small x evolution of gluon radiation for each of these three terms. The first term follows the same pattern of gluon radiation as the {gamma}{sup *}-initiated quark-antiquark dipole, and, in particular, it contains the BFKL evolution followed by the 2{yields}4 transition vertex (triple Pomeron vertex). The odderon-term is described by the standard BKP evolution, and the baryon couples to both known odderon solutions, the Janik-Wosiek solution and the BLV solution. Finally, the t-channel evolution of the third term starts with a three reggeized gluon state which then, via a new 3{yields}4 transition vertex, couples to the four gluon (two-Pomeron) state. We briefly discuss a few consequences of these findings, in particular the pattern of unitarization of high energy baryon scattering amplitudes. (orig.)

  18. Isolated lung events following radiation for early stage breast cancer: incidence and predictors for primary lung vs metastatic breast cancer

    International Nuclear Information System (INIS)

    Van Buren, Teresa A; Harris, Jay R; Sugarbaker, David J; Schneider, Lindsey; Healey, Elizabeth A

    1995-01-01

    Purpose: 1) To define the incidence of isolated lung events in a cohort of women treated with conservative surgery (CS) and radiation therapy (RT) for early stage breast cancer. 2) Among such patients, to define the relative distribution of primary lung cancer, metastatic breast cancer, and indeterminate lesions; and to identify any predictors for a diagnosis of lung vs metastatic breast cancer. 3) To examine the cohort with respect to whether a higher than expected incidence of lung cancer is seen following breast irradiation. Materials and Methods: Between 1968 and 1986, 1865 patients with clinical stage I-II breast cancer were treated with CS and RT; the median follow-up for surviving patients is 129 months. The study population was limited to patients who developed a subsequent isolated lung event as the first site of distant disease. Isolated lung event was defined as disease limited to the thoracic cavity, without evidence of either uncontrolled local breast disease or metastatic disease elsewhere. Diagnosis of the lung event as a primary lung cancer, a metastatic breast lesion, or an indeterminate lesion was documented from the viewpoint of 1) the pathologic analysis and 2) the clinical impression at the time of the lung event. Results: Sixty six of the 1865 patients (3.5%) developed an isolated lung event. The relative distribution of the pathologic and clinical diagnoses is shown below: The 66 lung events were characterized either as a solitary pulmonary nodule (27), multiple nodules (23), pleural effusion alone (10), unknown (2), or miscellaneous other findings (4). Among the 47 patients for whom pathology was available, the diagnosis remained indeterminate for 24 (51%). For patients with a definitive pathologic diagnosis, 69% ((9(13))) of smokers had a new lung cancer compared to 20% ((2(10))) of non-smokers (p=0.036), and 67% ((10(15))) of patients with a solitary pulmonary nodule had lung cancer compared to 14% ((1(7))) for other lung presentations (p

  19. Radiation induced cardiotoxicity in left sided breast cancer - Where do we stand?

    Directory of Open Access Journals (Sweden)

    Pamela Alice Kingsley

    2015-01-01

    Full Text Available Breast cancer is the commonest cancer in women, with around a million new cases diagnosed each year worldwide. Adjuvant radiotherapy (RT is an important component of therapy for many women with early-stage breast cancer. With improving survival rates following breast cancer, patients are increasingly likely to die of other causes. As a result, long-term adverse effects of treatment are of major concern. To determine which treatment is optimal, clinician need to be aware of long-term risks and benefits of adjuvant therapies. An awareness of the potential cardiotoxicity of RT led to the application of improved RT techniques that minimize the irradiation to the heart. Although new techniques, including intensity-modulated RT combined with free breathing gating and helical tomotherapy may further reduce radiation-induced cardiac toxicities, the most important factors in limiting cardiac radiation are associated with the techniques used and the skill of the radiation oncologist.

  20. Radiation dosimetry from breast milk excretion of radioiodine and pertechnetate

    International Nuclear Information System (INIS)

    Hedrick, W.R.; Di Simone, R.N.; Keen, R.L.

    1986-01-01

    Measurements were made of the activity in samples of breast milk obtained from a patient with postpartum thyroiditis following administration of [ 123 I]sodium iodide and subsequently [99mTc]pertechnetate 24 hr later. Both 123 I and 99mTc were found to be excreted exponentially with an effective half-life of 5.8 hr and 2.8 hr, respectively. Less than 10% of the activity was incorporated into breast-milk protein. After administration of [ 123 I]sodium iodide breast feeding should be discontinued for 24-36 hr to reduce the absorbed dose to the child's thyroid

  1. Non perturbative method for radiative corrections applied to lepton-proton scattering

    International Nuclear Information System (INIS)

    Chahine, C.

    1979-01-01

    We present a new, non perturbative method to effect radiative corrections in lepton (electron or muon)-nucleon scattering, useful for existing or planned experiments. This method relies on a spectral function derived in a previous paper, which takes into account both real soft photons and virtual ones and hence is free from infrared divergence. Hard effects are computed perturbatively and then included in the form of 'hard factors' in the non peturbative soft formulas. Practical computations are effected using the Gauss-Jacobi integration method which reduce the relevant integrals to a rapidly converging sequence. For the simple problem of the radiative quasi-elastic peak, we get an exponentiated form conjectured by Schwinger and found by Yennie, Frautschi and Suura. We compare also our results with the peaking approximation, which we derive independantly, and with the exact one-photon emission formula of Mo and Tsai. Applications of our method to the continuous spectrum include the radiative tail of the Δ 33 resonance in e + p scattering and radiative corrections to the Feynman scale invariant F 2 structure function for the kinematics of two recent high energy muon experiments

  2. An exploration in acoustic radiation force experienced by cylindrical shells via resonance scattering theory.

    Science.gov (United States)

    Rajabi, Majid; Behzad, Mehdi

    2014-04-01

    In nonlinear acoustic regime, a body insonified by a sound field is known to experience a steady force that is called the acoustic radiation force (RF). This force is a second-order quantity of the velocity potential function of the ambient medium. Exploiting the sufficiency of linear solution representation of potential function in RF formulation, and following the classical resonance scattering theorem (RST) which suggests the scattered field as a superposition of the resonant field and a background (non-resonant) component, we will show that the radiation force is a composition of three components: background part, resonant part and their interaction. Due to the nonlinearity effects, each part contains the contribution of pure partial waves in addition to their mutual interaction. The numerical results propose the residue component (i.e., subtraction of the background component from the RF) as a good indicator of the contribution of circumferential surface waves in RF. Defining the modal series of radiation force function and its components, it will be shown that within each partial wave, the resonance contribution can be synthesized as the Breit-Wigner form for adequately none-close resonant frequencies. The proposed formulation may be helpful essentially due to its inherent value as a canonical subject in physical acoustics. Furthermore, it may make a tunnel through the circumferential resonance reducing effects on radiation forces. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Evaluation of systematic uncertainties caused by radiative corrections in experiments on deep inelastic νsub(l)N-scattering

    International Nuclear Information System (INIS)

    Bardin, D.Yu.

    1979-01-01

    Basing on the simple quark-parton model of strong interaction and on the Weinberg-Salam theory compact formulae are derived for the radiative correction to the charged current induced deep inelastic scattering of neutrinos on nucleons. The radiative correction is found to be around 20-30%, i.e., the value typical for deep inelastic lN-scattering. The results obtained are rather different from the presently available estimations of the effect under consideration

  4. Current technological clinical practice in breast radiotherapy; results of a survey in EORTC-Radiation Oncology Group affiliated institutions

    NARCIS (Netherlands)

    van der Laan, Hans Paul; Hurkmans, Coen W; Kuten, Abraham; Westenberg, Helen A

    PURPOSE: To evaluate the current technological clinical practice of radiation therapy of the breast in institutions participating in the EORTC-Radiation Oncology Group (EORTC-ROG). MATERIALS AND METHODS: A survey was conducted between August 2008 and January 2009 on behalf of the Breast Working

  5. Ionizing radiation-induced DNA injury and damage detection in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Borrego-Soto, Gissela; Ortiz-Lopez, Rocio; Rojas-Martinez, Augusto, E-mail: arojasmtz@gmail.com, E-mail: augusto.rojasm@uanl.mx [Departamento de Bioquímica y Medicina Molecular, Facultad de Medicina, Universidad Autónoma de Nuevo León, Monterrey, Nuevo León (Mexico)

    2015-10-15

    Breast cancer is the most common malignancy in women. Radiotherapy is frequently used in patients with breast cancer, but some patients may be more susceptible to ionizing radiation, and increased exposure to radiation sources may be associated to radiation adverse events. This susceptibility may be related to deficiencies in DNA repair mechanisms that are activated after cell-radiation, which causes DNA damage, particularly DNA double strand breaks. Some of these genetic susceptibilities in DNA-repair mechanisms are implicated in the etiology of hereditary breast/ovarian cancer (pathologic mutations in the BRCA 1 and 2 genes), but other less penetrant variants in genes involved in sporadic breast cancer have been described. These same genetic susceptibilities may be involved in negative radiotherapeutic outcomes. For these reasons, it is necessary to implement methods for detecting patients who are susceptible to radiotherapy-related adverse events. This review discusses mechanisms of DNA damage and repair, genes related to these functions, and the diagnosis methods designed and under research for detection of breast cancer patients with increased radiosensitivity. (author)

  6. Cost-effectiveness and radiation risk of breast cancer screening

    International Nuclear Information System (INIS)

    Rombach, J.J.

    1987-01-01

    Base cost effectiveness risk associated with radiological screening for tuberculosis and lung tumor the Government of Netherlands advised against mass screening. However, mass screening remains an important method in the case of breast cancer

  7. Non-Directional Radiation Spread Modeling and Non-Invasive Estimating the Radiation Scattering and Absorption Parameters in Biological Tissue

    Directory of Open Access Journals (Sweden)

    S. Yu. Makarov

    2015-01-01

    Full Text Available The article dwells on a development of new non-invasive measurement methods of optical parameters of biological tissues, which are responsible for the scattering and absorption of monochromatic radiation. It is known from the theory of radiation transfer [1] that for strongly scattering media, to which many biological tissues pertain, such parameters are parameters of diffusion approximation, as well as a scattering coefficient and an anisotropy parameter.Based on statistical modeling the paper examines a spread of non-directional radiation from a Lambert light beam with the natural polarization that illuminates a surface of the biological tissue. Statistical modeling is based on the Monte Carlo method [2]. Thus, to have the correct energy coefficient values of Fresnel reflection and transmission in simulation of such radiation by Monte Carlo method the author uses his finding that is a function of the statistical representation for the incidence of model photons [3]. The paper describes in detail a principle of fixing the power transmitted by the non-directional radiation into biological tissue [3], and the equations of a power balance in this case.Further, the paper describes the diffusion approximation of a radiation transfer theory, often used in simulation of radiation propagation in strongly scattering media and shows its application in case of fixing the power transmitted into the tissue. Thus, to represent an uneven power distribution is used an approximating expression in conditions of fixing a total input power. The paper reveals behavior peculiarities of solution on the surface of the biological tissue inside and outside of the incident beam. It is shown that the solution in the region outside of the incident beam (especially far away from it, essentially, depends neither on the particular power distribution across the surface, being a part of the tissue, nor on the refractive index of the biological tissue. It is determined only by

  8. Multiple Scattering of Gamma Radiation in a Spherical Concrete Wall Room

    Energy Technology Data Exchange (ETDEWEB)

    Leimdoerfer, M

    1962-12-15

    The Monte Carlo method has been applied for the calculation of the energy flux of scattered gamma radiation in a spherical room surrounded by an infinitely thick spherical wall and with a point source at the centre. Source energies were I, 2, 4, 6, and 10 MeV. The main investigation was carried out at a room radius of 500 cm but, for the 1 MeV source, the influence of varying the room radius down to 1 cm was analysed. The results contain energy distributions of the first four successive reflection components at the centre of the room and at the wall surface, as well as spatial distributions of the successive energy flux components. The neglect of reflection contributions of order five and higher was estimated to introduce an error of less than 0. 2 % of the total scattered energy flux. An analytical approximation is shown to produce a useful and easily applicable method of predicting the amount of scattered radiation in a spherical room.

  9. First observation of the depolarization of Thomson scattering radiation by a fusion plasma

    Science.gov (United States)

    Giudicotti, L.; Kempenaars, M.; McCormack, O.; Flanagan, J.; Pasqualotto, R.; contributors, JET

    2018-04-01

    We report the first experimental observation of the depolarization of the Thomson scattering (TS) radiation, a relativistic effect expected to occur in very high {{T}e} plasmas and never observed so far in a fusion machine. A set of unused optical fibers in the collection optics of the high resolution Thomson scattering system of JET has been used to detect the depolarized TS radiation during a JET campaign with {{T}e}≤slant 8 keV . A linear polarizer with the axis perpendicular to the direction of the incident E-field was placed in front of a fiber optic pair observing a region close to the plasma core, while another fiber pair with no polariser simultaneously observed an adjacent plasma region. The measured intensity ratio was found to be consistent with the theory, taking into account sensitivity coefficients of the two measurement channels determined with post-experiment calibrations and Raman scattering. This depolarization effect is at the basis of polarimetric TS, a different and complementary method for the analysis of TS spectra that can provide significant advantages for {{T}e} measurements in very hot plasmas such as in ITER ≤ft({{T}e}≤slant 40 keV \\right) .

  10. Multiple Scattering of Gamma Radiation in a Spherical Concrete Wall Room

    International Nuclear Information System (INIS)

    Leimdoerfer, M.

    1962-12-01

    The Monte Carlo method has been applied for the calculation of the energy flux of scattered gamma radiation in a spherical room surrounded by an infinitely thick spherical wall and with a point source at the centre. Source energies were I, 2, 4, 6, and 10 MeV. The main investigation was carried out at a room radius of 500 cm but, for the 1 MeV source, the influence of varying the room radius down to 1 cm was analysed. The results contain energy distributions of the first four successive reflection components at the centre of the room and at the wall surface, as well as spatial distributions of the successive energy flux components. The neglect of reflection contributions of order five and higher was estimated to introduce an error of less than 0. 2 % of the total scattered energy flux. An analytical approximation is shown to produce a useful and easily applicable method of predicting the amount of scattered radiation in a spherical room

  11. Effect of infrared radiation on the threshold behavior of scattering (and decay) processes

    International Nuclear Information System (INIS)

    Mohanty, A.K.; Rosenberg, L.; Spruch, L.

    1988-01-01

    An analysis is given of the effect of radiative corrections on the threshold behavior of the cross section for the inelastic scattering of a light charged particle by a neutral composite system. Explicit results are obtained for a model problem where the target consists of a proton and antiproton bound under their mutual Coulomb interaction and excited to a 2p state from its 1s ground state by electron impact, but the conclusions drawn are applicable, qualitatively, to a wide range of problems. It is found that when the energy resolution Δepsilon-c of the electron detector is small compared with the kinetic energy K' of the electron in the final state, the more careful treatment given here, which properly accounts for the rapid variation of the cross section for scattering energies near threshold, leads to only small modifications in the standard form of the radiative correction factor δ. For sufficiently high resolution in energy of a (high-energy) incident beam, the modification could be significant if Δepsilon-c is comparable with K'. The above considerations are applicable not only to scattering cross sections but to endpoints of the energy spectrum of the charged particle in a decay process in which only one charged particle is emitted

  12. A case of likely radiation-induced synchronous esophageal and skin carcinoma following post-operative radiation for breast cancer

    International Nuclear Information System (INIS)

    Kanogawa, Naoya; Shimada, Hideaki; Kainuma, Osamu; Cho, Akihiro; Yamamoto, Hiroshi; Itami, Makiko; Nagata, Matsuo

    2009-01-01

    A 71-year-old woman was admitted in January 2008 with on upper thoracic esophageal squamous cell carcinoma and a right chest wall skin tumor. When she was 32 years old, she had a radical mastectomy for right breast cancer and received postoperative radiation. Due to the presence of lung adhesions, trans-thoracic esophagectomy could not be done; thus, a blunt dissection was performed. She was discharged on the 19 th postoperative day. On pathology, a pT2N0M0 (pStage II) esophageal tumor was diagnosed. A resection of her skin tumor underwent 79 days after the esophageal surgery; on pathology, the skin tumor was diagnosed as a basal cell carcinoma. Since the esophageal tumor and the skin tumor occurred in the same area that had received radiation therapy, these tumors were diagnosed as being radiation-induced secondary tumors. In the English language medical literature, several reports of radiation-induced esophageal cancer occurring as a second cancer after radiotherapy for breast cancer have been published. Radiation-induced esophageal cancer rates may increase in Japan given the number of women who previously received radiotherapy for breast cancer. (author)

  13. Breast cancer early detection via tracking of skin back-scattered secondary speckle patterns

    Science.gov (United States)

    Bennett, Aviya; Sirkis, Talia; Beiderman, Yevgeny; Agdarov, Sergey; Beiderman, Yafim; Zalevsky, Zeev

    2018-02-01

    Breast cancer has become a major cause of death among women. The lifetime risk of a woman developing this disease has been established as one in eight. The most useful way to reduce breast cancer death is to treat the disease as early as possible. The existing methods of early diagnostics of breast cancer are mainly based on screening mammography or Magnetic Resonance Imaging (MRI) periodically conducted at medical facilities. In this paper the authors proposing a new approach for simple breast cancer detection. It is based on skin stimulation by sound waves, illuminating it by laser beam and tracking the reflected secondary speckle patterns. As first approach, plastic balls of different sizes were placed under the skin of chicken breast and detected by the proposed method.

  14. SASKTRAN: A spherical geometry radiative transfer code for efficient estimation of limb scattered sunlight

    International Nuclear Information System (INIS)

    Bourassa, A.E.; Degenstein, D.A.; Llewellyn, E.J.

    2008-01-01

    The inversion of satellite-based observations of limb scattered sunlight for the retrieval of constituent species requires an efficient and accurate modelling of the measurement. We present the development of the SASKTRAN radiative transfer model for the prediction of limb scatter measurements at optical wavelengths by method of successive orders along rays traced in a spherical atmosphere. The component of the signal due to the first two scattering events of the solar beam is accounted for directly along rays traced in the three-dimensional geometry. Simplifying assumptions in successive scattering orders provide computational optimizations without severely compromising the accuracy of the solution. SASKTRAN is designed for the analysis of measurements from the OSIRIS instrument and the implementation of the algorithm is efficient such that the code is suitable for the inversion of OSIRIS profiles on desktop computers. SASKTRAN total limb radiance profiles generally compare better with Monte-Carlo reference models over a large range of solar conditions than the approximate spherical and plane-parallel models typically used for inversions

  15. WE-EF-207-06: Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio

    International Nuclear Information System (INIS)

    Shi, L; Vedantham, S; Karellas, A

    2015-01-01

    Purpose: To determine the spatial distribution of x-ray scatter and scatter-to-primary ratio (SPR) in projections during cone-beam breast CT (CBBCT) with laterally-shifted detector that results in coronal (fan-angle) truncation. Methods: We hypothesized that CBBCT with coronal truncation would lower SPR due to reduction in irradiated breast volume, and that the location of maximum x-ray scatter fluence (scatter-peak) in the detector plane can be determined from the ratio of irradiated-to-total breast volume, breast dimensions and system geometry. Monte Carlo simulations (GEANT4) reflecting a prototype CBBCT system were used to record the position-dependent primary and scatter x-ray photon fluence incident on the detector without coronal truncation (full fan-angle, 2f=24-degrees) and with coronal truncation (fan-angle, f+ f=12+2.7-degrees). Semi-ellipsoidal breasts (10/14/18-cm diameter, chest-wall to nipple length: 0.75xdiameter, 2%/14%/100% fibroglandular content) aligned with the axis-of-rotation (AOR) were modeled. Mono-energy photons were simulated and weighted for 2 spectra (49kVp, 1.4-mm Al HVL; 60kVp, 3.76-mm Al HVL). In addition to SPR, the scatter maps were analyzed to identify the location of the scatter-peak. Results: For CBBCT without fan-angle truncation, the scatter-peaks were aligned with the projection of the AOR onto the detector for all breasts. With truncated fan-beam, the scatter-peaks were laterally-shifted from the projection of the AOR along the fan-angle direction by 14/38/70-pixels for 10/14/18-cm diameter breasts. The corresponding theoretical shifts were 14.8/39.7/68-pixels (p=0.47, 2-tailed paired-ratio t-test). Along the cone-angle, the shift in scatter-peaks between truncated and full-fan angle CBBCT were 2/2/4 -pixels for 10/14/18-cm diameter breasts. CBBCT with fan-angle truncation reduced SPR by 14/22/28% for 10/14/18-cm diameter breasts. 60kVp reduced SPR by 21–25% compared to 49kVp. Peak SPR for CBBCT with fan-angle truncation

  16. The incidence of breast cancer following mantle field radiation therapy as a function of dose and technique

    International Nuclear Information System (INIS)

    Tinger, Alfred; Wasserman, Todd H.; Klein, Eric E.; Miller, Elizabeth A.; Roberts, Tracy; Piephoff, James V.; Kucik, Nancy A.

    1997-01-01

    Purpose: There is an increased incidence of breast cancer following mantle field radiation therapy for Hodgkin's disease (HD). We reviewed the experience at the Mallinckrodt Institute of Radiology (MIR) for radiation factors related to the development of breast cancer after mantle field radiation therapy for HD. Methods: The radiation therapy records of 152 women treated with mantle field irradiation for HD at MIR between 1966-1985 were reviewed for the development of breast cancer and treatment-related factors. All patients had a minimum of 5 years of follow-up. The treatment era (1966-1974 vs. 1975-1985), stage of HD, mediastinal dose, axillary dose, maximum dose from the anterior field (anterior d max dose), the anterior-posterior:posterior-anterior (AP:PA) ratio, age at the time of treatment, length of follow-up, and history of splenectomy were analyzed as possible contributing factors for the development of breast cancer. The observed number of breast cancers was compared to the expected number based on age-adjusted incidences from the Connecticut Tumor Registry. Results: Ten breast cancers occurred in the population. Eight involved an upper outer quadrant. In a multivariate analysis, the development of breast cancer was significantly associated with axillary dose. Patients in the early treatment era were at an increased risk for the development of breast cancer due to high anterior d max and breast doses from weighting the fields anteriorly on a low energy linear accelerator. The use of current radiation therapy techniques was not related to an increased risk of breast cancer with a median follow-up of 13 years. Conclusions: A high dose to the axilla and the anterior d max point is significantly associated with the development of breast cancer after mantle field irradiation for HD. Efforts to protect the breast from high doses will likely lessen the increased risk of breast cancer in women treated with radiation therapy for HD

  17. Coupled radiative transfer equation and diffusion approximation model for photon migration in turbid medium with low-scattering and non-scattering regions

    International Nuclear Information System (INIS)

    Tarvainen, Tanja; Vauhkonen, Marko; Kolehmainen, Ville; Arridge, Simon R; Kaipio, Jari P

    2005-01-01

    In this paper, a coupled radiative transfer equation and diffusion approximation model is extended for light propagation in turbid medium with low-scattering and non-scattering regions. The light propagation is modelled with the radiative transfer equation in sub-domains in which the assumptions of the diffusion approximation are not valid. The diffusion approximation is used elsewhere in the domain. The two equations are coupled through their boundary conditions and they are solved simultaneously using the finite element method. The streamline diffusion modification is used to avoid the ray-effect problem in the finite element solution of the radiative transfer equation. The proposed method is tested with simulations. The results of the coupled model are compared with the finite element solutions of the radiative transfer equation and the diffusion approximation and with results of Monte Carlo simulation. The results show that the coupled model can be used to describe photon migration in turbid medium with low-scattering and non-scattering regions more accurately than the conventional diffusion model

  18. Scatter radiation dose at height of the lens and image quality in interventional cardiology

    International Nuclear Information System (INIS)

    Leguees, Fernando A. Leyton

    2016-01-01

    Cardiologist and other staff members receive high doses of scattered radiation. Cases of radiation-induced cataract among cardiology professionals have been reported in studies, estimates for the dose to eye lens ranged from 450 to 900 mSv per year (without ceiling suspended screen), over several years. Recent surveys regarding high prevalence of lens changes likely induced by radiation exposure suggest an urgent need for improved radiation safety and training, use of eye protection during catheterization procedures, and improved occupational dosimetry. In view of the evidence of radiation injuries, the ICRP recommends limiting the radiation dose to the lens to 20 mSv per year for occupational exposure. A system for optimizing the radiation exposure is the measurement of entrance surface air kerma (K a,e ) and kerma-area product (P KA ) for patient and scattered dose or dose rate at the position for the staff, under clinical working conditions using phantoms and defined technical factors. Correlating K a,e and P KA with the scatter dose, applying the attenuation factors protective devices can enable estimation of the lens doses for operators. The purpose of this work is: to study the possibility of establishing a procedure which is useful for scientific societies and the regulatory authority in the prevention and control of IOE dose and to control and improve the quality of procedures in interventional cardiology as an initiative to raise awareness and optimization of radiological protection. Measurements were taken in different cardiac laboratories. Clinical working conditions were reproduced during the experiments for the different hemodynamic angiographic projections and operating modes used in fluoroscopy and cine. A first K a,e rate reference proposal for the characterization of angiography for the different acquisition modes were 16; 35; 40 and 220 (mGy/min), respectively. Considering the typical PKA values to patient in interventional cardiology procedures

  19. Doubly-scattered-radiation contribution to Lidar returns from fog, evaluated by means of a simple geometrical approach

    International Nuclear Information System (INIS)

    Bruscaglioni, P.; Ismaelli, A.

    1978-01-01

    The contribution of doubly scattered radiation to the return of a monostatic Lidar, used for measurement of atmospheric visibility, is evaluated by means of a simple geometrical scheme. A very narrow laser beam is considered, to obtain an expression of the ratio D/S of doubly scattered power to singly scattered power. This assumption allows an easy consideration of any angle of scattering and the introduction of time into the calculations. Numerical computations are performed for several models of fog. Our results are similar, though a little lower, than the results of other theoretical treatments of this problem based on different assumptions. (author)

  20. Association between skin phototype and radiation dermatitis in patients with breast cancer treated with breast-conserving therapy. Suntan reaction could be a good predictor for radiation pigmentation

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Nishimura, Takuya; Kobayashi, Kana; Tsubokura, Takuji; Kodani, Naohiro; Aibe, Norihiro; Nishimura, Tsunehiko; Yoshida, Ken

    2011-01-01

    The purpose of this study was to evaluate the significance of skin phototype (suntan or sunburn type) in association with radiation dermatitis in patients with breast cancer who underwent postoperative radiotherapy after breast-conserving surgery because phototype could predict sunlight reaction. We divided patients into two phototypes (58 suntan/darkening and 28 sunburn/reddening types) according to self-reports before radiotherapy. We examined skin color changes in 86 patients who underwent breast-conserving surgery followed by 50 Gy/25 fractions (median) of radiotherapy with or without boost radiation (10 Gy/5 fractions). Color change was assessed according to CIE L*a*b* space, which is defined by the Commission Internationale de l'Eclairage (CIE) in 1976 for quantitative color assessment. The patients were also assessed by individual typology angle (ITA deg; indicator of skin color calculated by L*a*b* space) and Common Terminology Criteria for Adverse Event v3.0 (CTCAE v3). Radiation therapy changed all values except the b* value, and the suntan type showed a greater darkening response associated with radiation dermatitis than did the sunburn type in terms of ITA deg value change (p=0.04), whereas the sunburn type did not show higher a* value (reddening). By CTCAE v3 classifications, a Grade 2 reaction appeared in 14% sunburn patients and in 31% of the suntan group, respectively (p=0.16). Suntan type predicted higher pigmentation associated with radiation dermatitis. Self-reported phototype has the potential to be a good predictor of skin sensitivity to radiation exposure for clinical screening. (author)

  1. Revisiting Bragg's X-ray microscope: scatter based optical transient grating detection of pulsed ionising radiation.

    Science.gov (United States)

    Fullagar, Wilfred K; Paganin, David M; Hall, Chris J

    2011-06-01

    Transient optical gratings for detecting ultrafast signals are routine for temporally resolved photochemical investigations. Many processes can contribute to the formation of such gratings; we indicate use of optically scattering centres that can be formed with highly variable latencies in different materials and devices using ionising radiation. Coherent light scattered by these centres can form the short-wavelength-to-optical-wavelength, incoherent-to-coherent basis of a Bragg X-ray microscope, with inherent scope for optical phasing. Depending on the dynamics of the medium chosen, the way is open to both ultrafast pulsed and integrating measurements. For experiments employing brief pulses, we discuss high-dynamic-range short-wavelength diffraction measurements with real-time optical reconstructions. Applications to optical real-time X-ray phase-retrieval are considered. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Caloric Restriction in Treating Patients With Stage 0-I Breast Cancer Undergoing Surgery and Radiation Therapy

    Science.gov (United States)

    2017-09-25

    Ductal Breast Carcinoma in Situ; Invasive Ductal Breast Carcinoma; Invasive Lobular Breast Carcinoma; Lobular Breast Carcinoma in Situ; Recurrent Breast Cancer; Stage IA Breast Cancer; Stage IB Breast Cancer

  3. Using mortality data to estimate radiation effects on breast cancer incidence

    International Nuclear Information System (INIS)

    Hoel, D.G.; Dinse, G.E.

    1990-01-01

    In this paper we combine Japanese data on radiation exposure and cancer mortality with U.S. data on cancer incidence and lethality to estimate the effects of ionizing radiation on cancer incidence. The analysis is based on the mathematical relationship between the mortality rate and the incidence and lethality rates, as well as on statistical models that relate Japanese incidence rates to U.S. incidence rates and radiation risk factors. Our approach assumes that the risk of death from causes other than the cancer does not depend on whether or not the cancer is present, and among individuals with the cancer, the risk of death attributable to the cancer is the same in Japan and the U.S. and is not affected by radiation exposure. In particular, we focus on the incidence of breast cancer in Japanese women and how this incidence is affected by radiation risk factors. The analysis uses Japanese exposure and mortality data from the Radiation Effects Research Foundation study of atomic bomb survivors and U.S. incidence and lethality data from the Surveillance, Epidemiology, and End Results Registry. Even without Japanese incidence data, we obtain reasonable estimates of the incidence of breast cancer in unexposed Japanese women and identify the radiation risk factors that affect this incidence. Our analysis demonstrates that the age at exposure is an important risk factor, but that the incidence of breast cancer is not affected by the city of residence (Nagasaki versus Hiroshima) or the time since exposure

  4. Mometasone Furoate Cream Reduces Acute Radiation Dermatitis in Patients Receiving Breast Radiation Therapy: Results of a Randomized Trial

    International Nuclear Information System (INIS)

    Hindley, Andrew; Zain, Zakiyah; Wood, Lisa; Whitehead, Anne; Sanneh, Alison; Barber, David; Hornsby, Ruth

    2014-01-01

    Purpose: We wanted to confirm the benefit of mometasone furoate (MF) in preventing acute radiation reactions, as shown in a previous study (Boström et al, Radiother Oncol 2001;59:257-265). Methods and Materials: The study was a double-blind comparison of MF with D (Diprobase), administered daily from the start of radiation therapy for 5 weeks in patients receiving breast radiation therapy, 40 Gy in 2.67-Gy fractions daily over 3 weeks. The primary endpoint was mean modified Radiation Therapy Oncology Group (RTOG) score. Results: Mean RTOG scores were significantly less for MF than for D (P=.046). Maximum RTOG and mean erythema scores were significantly less for MF than for D (P=.018 and P=.012, respectively). The Dermatology Life Quality Index (DLQI) score was significantly less for MF than for D at weeks 4 and 5 when corrected for Hospital Anxiety and Depression (HAD) questionnaire scores. Conclusions: MF cream significantly reduces radiation dermatitis when applied to the breast during and after radiation therapy. For the first time, we have shown a significantly beneficial effect on quality of life using a validated instrument (DLQI), for a topical steroid cream. We believe that application of this cream should be the standard of care where radiation dermatitis is expected

  5. Mometasone Furoate Cream Reduces Acute Radiation Dermatitis in Patients Receiving Breast Radiation Therapy: Results of a Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Hindley, Andrew, E-mail: andrew.hindley@lthtr.nhs.uk [Rosemere Cancer Centre, Royal Preston Hospital, Preston (United Kingdom); Zain, Zakiyah [College of Arts and Sciences, Universiti Utara Malaysia, Kedah (Malaysia); Wood, Lisa [Department of Social Sciences, Lancaster Medical School, Lancaster (United Kingdom); Whitehead, Anne [Medical and Pharmaceutical Statistics Research Unit, Lancaster University, Lancaster (United Kingdom); Sanneh, Alison; Barber, David; Hornsby, Ruth [Rosemere Cancer Centre, Royal Preston Hospital, Preston (United Kingdom)

    2014-11-15

    Purpose: We wanted to confirm the benefit of mometasone furoate (MF) in preventing acute radiation reactions, as shown in a previous study (Boström et al, Radiother Oncol 2001;59:257-265). Methods and Materials: The study was a double-blind comparison of MF with D (Diprobase), administered daily from the start of radiation therapy for 5 weeks in patients receiving breast radiation therapy, 40 Gy in 2.67-Gy fractions daily over 3 weeks. The primary endpoint was mean modified Radiation Therapy Oncology Group (RTOG) score. Results: Mean RTOG scores were significantly less for MF than for D (P=.046). Maximum RTOG and mean erythema scores were significantly less for MF than for D (P=.018 and P=.012, respectively). The Dermatology Life Quality Index (DLQI) score was significantly less for MF than for D at weeks 4 and 5 when corrected for Hospital Anxiety and Depression (HAD) questionnaire scores. Conclusions: MF cream significantly reduces radiation dermatitis when applied to the breast during and after radiation therapy. For the first time, we have shown a significantly beneficial effect on quality of life using a validated instrument (DLQI), for a topical steroid cream. We believe that application of this cream should be the standard of care where radiation dermatitis is expected.

  6. Dosimetric measurement of scattered radiation from dental implants in simulated head and neck radiotherapy.

    Science.gov (United States)

    Wang, R; Pillai, K; Jones, P K

    1998-01-01

    The purpose of this study was to examine the dose enhancement at bone-implant interfaces from scattered radiation during simulated head and neck radiotherapy. Three cylindric implant systems with different compositions (pure titanium, titanium-aluminum-vanadium alloy, titanium coated with hydroxyapatite) and a high gold content transmandibular implant system (gold-copper-silver alloy) were studied. Extruded lithium fluoride single crystal chips were used as thermoluminescent material to measure radiation dose enhancement at 0, 1, and 2 mm from the bone-implant interface. The relative doses in buccal, lingual, mesial, and distal directions were also recorded and compared. The results indicated that the highest dose enhancement occurred at a distance of 0 mm from the bone-implant interface for all the implant systems studied. The transmandibular implants had higher scattered radiation than other groups at 0 mm and at 1 mm from the bone-implant interface. There was no significant difference of dose enhancement between buccal, lingual, mesial, and distal directions. Titanium implants coated with hydroxyapatite demonstrated the best results under the simulated irradiation.

  7. Least-squares collocation meshless approach for radiative heat transfer in absorbing and scattering media

    Science.gov (United States)

    Liu, L. H.; Tan, J. Y.

    2007-02-01

    A least-squares collocation meshless method is employed for solving the radiative heat transfer in absorbing, emitting and scattering media. The least-squares collocation meshless method for radiative transfer is based on the discrete ordinates equation. A moving least-squares approximation is applied to construct the trial functions. Except for the collocation points which are used to construct the trial functions, a number of auxiliary points are also adopted to form the total residuals of the problem. The least-squares technique is used to obtain the solution of the problem by minimizing the summation of residuals of all collocation and auxiliary points. Three numerical examples are studied to illustrate the performance of this new solution method. The numerical results are compared with the other benchmark approximate solutions. By comparison, the results show that the least-squares collocation meshless method is efficient, accurate and stable, and can be used for solving the radiative heat transfer in absorbing, emitting and scattering media.

  8. Evaluation of the spectral distribution of X-ray beams from measurements on the scattered radiation

    International Nuclear Information System (INIS)

    Casnati, E.; Baraldi, C.

    1980-01-01

    Most of the phenomena activated by photons with energies below 100 keV show an apparent or real dependence on the quantum energy. Therefore, knowledge of the beam energy characteristics is of primary importance for interpretation of the irradiation results. The greatest difficulty arises from the high flux density of the beams usually employed which does not allow direct measurements of the beam. A method was developed which permits evaluation of the spectral distribution of the X-ray beam from a spectrometric measurement of the radiation scattered by a thin foil of a suitable metal. This makes possible a new and more rational approach to the measurement of X-rays in the energy range where the interaction parameters show a large photon energy dependence. The corrections required by the presence of some collateral effects, among which the most important is the coexistence of the coherent and incoherent scattering, must be evaluated. The knowledge of the spectral distribution is of immediate usefulness for studies of radiation damage in biological and other materials, for the calibration of radiation measuring instruments and for the improvement of the radiological instrumentation response which contributes to reducing the patient's dose. (H.K.)

  9. H(10) due to radiation scattered in a 6 MV Linac for tomotherapy

    International Nuclear Information System (INIS)

    Vega C, H. R.; Esparza H, A.; Garcia R, M. G.; Reyes R, E.; Hernandez A, L.; Rivera, T.

    2017-10-01

    In order to determine the environmental equivalent dose (H(10)), due to the radiation that is dispersed over the body of a patient, 100 thermoluminescent dosimeters (TLD) around 6 MV TomoLINAC were used. The characteristics of the tomotherapy have the disadvantage that the shielding of the bunker increases considerably and for its design validated parameters are used for the conventional Linacs. In order to determine H(10) due to scattered radiation, measurements were made in the vicinity of the isocenter, while the 6 MeV photon beam was applied on a phantom. Also, TLDs were placed on the walls of the bunker that remained for 7 days, where approximately 50 patients were treated per day. At points close to the isocenter, the H(10) has an angular distribution caused by the phantom shape. In the bunker walls the highest H(10) was observed in the primary barriers. In the labyrinth, the impact of the scattered radiation was observed when measuring a greater value of the environmental equivalent dose in the wall furthest from the isocenter compared to the point located closest to it. (Author)

  10. Least-squares collocation meshless approach for radiative heat transfer in absorbing and scattering media

    International Nuclear Information System (INIS)

    Liu, L.H.; Tan, J.Y.

    2007-01-01

    A least-squares collocation meshless method is employed for solving the radiative heat transfer in absorbing, emitting and scattering media. The least-squares collocation meshless method for radiative transfer is based on the discrete ordinates equation. A moving least-squares approximation is applied to construct the trial functions. Except for the collocation points which are used to construct the trial functions, a number of auxiliary points are also adopted to form the total residuals of the problem. The least-squares technique is used to obtain the solution of the problem by minimizing the summation of residuals of all collocation and auxiliary points. Three numerical examples are studied to illustrate the performance of this new solution method. The numerical results are compared with the other benchmark approximate solutions. By comparison, the results show that the least-squares collocation meshless method is efficient, accurate and stable, and can be used for solving the radiative heat transfer in absorbing, emitting and scattering media

  11. Effective radiation attenuation calibration for breast density: compression thickness influences and correction

    Directory of Open Access Journals (Sweden)

    Thomas Jerry A

    2010-11-01

    Full Text Available Abstract Background Calibrating mammograms to produce a standardized breast density measurement for breast cancer risk analysis requires an accurate spatial measure of the compressed breast thickness. Thickness inaccuracies due to the nominal system readout value and compression paddle orientation induce unacceptable errors in the calibration. Method A thickness correction was developed and evaluated using a fully specified two-component surrogate breast model. A previously developed calibration approach based on effective radiation attenuation coefficient measurements was used in the analysis. Water and oil were used to construct phantoms to replicate the deformable properties of the breast. Phantoms consisting of measured proportions of water and oil were used to estimate calibration errors without correction, evaluate the thickness correction, and investigate the reproducibility of the various calibration representations under compression thickness variations. Results The average thickness uncertainty due to compression paddle warp was characterized to within 0.5 mm. The relative calibration error was reduced to 7% from 48-68% with the correction. The normalized effective radiation attenuation coefficient (planar representation was reproducible under intra-sample compression thickness variations compared with calibrated volume measures. Conclusion Incorporating this thickness correction into the rigid breast tissue equivalent calibration method should improve the calibration accuracy of mammograms for risk assessments using the reproducible planar calibration measure.

  12. WE-DE-207B-10: Library-Based X-Ray Scatter Correction for Dedicated Cone-Beam Breast CT: Clinical Validation

    Energy Technology Data Exchange (ETDEWEB)

    Shi, L; Zhu, L [Georgia Institute of Technology, Atlanta, GA (Georgia); Vedantham, S; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: Scatter contamination is detrimental to image quality in dedicated cone-beam breast CT (CBBCT), resulting in cupping artifacts and loss of contrast in reconstructed images. Such effects impede visualization of breast lesions and the quantitative accuracy. Previously, we proposed a library-based software approach to suppress scatter on CBBCT images. In this work, we quantify the efficacy and stability of this approach using datasets from 15 human subjects. Methods: A pre-computed scatter library is generated using Monte Carlo simulations for semi-ellipsoid breast models and homogeneous fibroglandular/adipose tissue mixture encompassing the range reported in literature. Projection datasets from 15 human subjects that cover 95 percentile of breast dimensions and fibroglandular volume fraction were included in the analysis. Our investigations indicate that it is sufficient to consider the breast dimensions alone and variation in fibroglandular fraction does not significantly affect the scatter-to-primary ratio. The breast diameter is measured from a first-pass reconstruction; the appropriate scatter distribution is selected from the library; and, deformed by considering the discrepancy in total projection intensity between the clinical dataset and the simulated semi-ellipsoidal breast. The deformed scatter-distribution is subtracted from the measured projections for scatter correction. Spatial non-uniformity (SNU) and contrast-to-noise ratio (CNR) were used as quantitative metrics to evaluate the results. Results: On the 15 patient cases, our method reduced the overall image spatial non-uniformity (SNU) from 7.14%±2.94% (mean ± standard deviation) to 2.47%±0.68% in coronal view and from 10.14%±4.1% to 3.02% ±1.26% in sagittal view. The average contrast to noise ratio (CNR) improved by a factor of 1.49±0.40 in coronal view and by 2.12±1.54 in sagittal view. Conclusion: We demonstrate the robustness and effectiveness of a library-based scatter correction

  13. A novel radiation detector for removing scattered radiation in chest radiography: Monte Carlo simulation-based performance evaluation

    Science.gov (United States)

    Roh, Y. H.; Yoon, Y.; Kim, K.; Kim, J.; Kim, J.; Morishita, J.

    2016-10-01

    Scattered radiation is the main reason for the degradation of image quality and the increased patient exposure dose in diagnostic radiology. In an effort to reduce scattered radiation, a novel structure of an indirect flat panel detector has been proposed. In this study, a performance evaluation of the novel system in terms of image contrast as well as an estimation of the number of photons incident on the detector and the grid exposure factor were conducted using Monte Carlo simulations. The image contrast of the proposed system was superior to that of the no-grid system but slightly inferior to that of the parallel-grid system. The number of photons incident on the detector and the grid exposure factor of the novel system were higher than those of the parallel-grid system but lower than those of the no-grid system. The proposed system exhibited the potential for reduced exposure dose without image quality degradation; additionally, can be further improved by a structural optimization considering the manufacturer's specifications of its lead contents.

  14. Radiative transfer equation accounting for rotational Raman scattering and its solution by the discrete-ordinates method

    International Nuclear Information System (INIS)

    Rozanov, Vladimir V.; Vountas, Marco

    2014-01-01

    Rotational Raman scattering of solar light in Earth's atmosphere leads to the filling-in of Fraunhofer and telluric lines observed in the reflected spectrum. The phenomenological derivation of the inelastic radiative transfer equation including rotational Raman scattering is presented. The different forms of the approximate radiative transfer equation with first-order rotational Raman scattering terms are obtained employing the Cabannes, Rayleigh, and Cabannes–Rayleigh scattering models. The solution of these equations is considered in the framework of the discrete-ordinates method using rigorous and approximate approaches to derive particular integrals. An alternative forward-adjoint technique is suggested as well. A detailed description of the model including the exact spectral matching and a binning scheme that significantly speeds up the calculations is given. The considered solution techniques are implemented in the radiative transfer software package SCIATRAN and a specified benchmark setup is presented to enable readers to compare with own results transparently. -- Highlights: • We derived the radiative transfer equation accounting for rotational Raman scattering. • Different approximate radiative transfer approaches with first order scattering were used. • Rigorous and approximate approaches are shown to derive particular integrals. • An alternative forward-adjoint technique is suggested as well. • An additional spectral binning scheme which speeds up the calculations is presented

  15. A case of leukoencephalopathy caused by radiation and chemotherapy for brain metastasis of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Shigeru; Sonoo, Hiroshi; Nomura, Tsunehisa; Ohkubo, Sumiko; Yamamoto, Yutaka; Tanaka, Katsuhiro; Kurebayashi, Junichi; Hiratsuka, Junichi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    2002-08-01

    A case of treatment-related leukoencephalopathy is presented. A patient with breast cancer metastasis to the brain, liver, bone and distant lymph nodes was treated with whole brain radiation and docetaxcel. Eleven months after radiation, magnetic resonance imaging showed diffuse leukoencephalopathy. Twenty-two months after radiation, the patient had gait disturbance, parkinsonism, dementia and urinary incontinence. From this experience, stereotactic radiosurgery such as cyber knife and gamma knife therapy, representing a new modality for delivering intense focal radiation, should be come preferred techniques for treating patients with brain metastases, to avoid the potential cognitive side effects of fractionated whole-brain radiotherapy. (author)

  16. Reducing radiation dose to the female breast during conventional and dedicated breast computed tomography

    Science.gov (United States)

    Rupcich, Franco John

    The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the need to run Monte Carlo simulations. The database was used to estimate breast dose for simulated CT images acquired for a reference protocol and five protocols intended to reduce breast dose. For each protocol, the performance of two tasks (detection of signals with unknown locations) was compared over a range of breast dose levels using a task-based, signal-detectability metric: the estimator of the area under the exponential free-response relative operating characteristic curve, AFE. For large-diameter/medium-contrast signals, when maintaining equivalent AFE, the 80 kV partial, 80 kV, 120 kV partial, and 120 kV tube-current modulated protocols reduced breast dose by 85%, 81%, 18%, and 6%, respectively, while the shielded protocol increased breast dose by 68%. Results for the small-diameter/high-contrast signal followed similar trends, but with smaller magnitude of the percent changes in dose. The 80 kV protocols demonstrated the greatest reduction to breast dose, however, the subsequent increase in noise may be clinically unacceptable. Tube output for these protocols can be adjusted to achieve more desirable noise levels with lesser dose reduction. The improvement in CNR of optimally projection-based and image-based weighted images relative to photon

  17. Radiation dosimetry in digital breast tomosynthesis: Report of AAPM Tomosynthesis Subcommittee Task Group 223

    Energy Technology Data Exchange (ETDEWEB)

    Sechopoulos, Ioannis, E-mail: isechop@emory.edu [Departments of Radiology and Imaging Sciences, Hematology and Medical Oncology and Winship Cancer Institute, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 (United States); Sabol, John M. [GE Healthcare, Global Diagnostic X-Ray, Mailstop W-701, 3000 North Grandview Boulevard, Waukesha, Wisconsin 53188 (United States); Berglund, Johan [Research and Development, Philips Women' s Healthcare, Solna (Sweden); Bolch, Wesley E. [J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611 (United States); Brateman, Libby [University of Florida, Gainesville, Florida 32611 (United States); Christodoulou, Emmanuel; Goodsitt, Mitchell [Department of Radiology, University of Michigan, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Flynn, Michael [Department of Radiology, Henry Ford Health System, Radiology Research 2F, 1 Ford Place, Detroit, Michigan 48202 (United States); Geiser, William [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States); Kyle Jones, A. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Lo, Joseph Y.; Paul Segars, W. [Department of Radiology, Medical Physics Graduate Program, and Department of Biomedical Engineering, Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Maidment, Andrew D. A. [Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania 19104-4206 (United States); Nishino, Kazuyoshi [R and D X-ray Products Group, Shimadzu Corporation, Tokyo (Japan); Nosratieh, Anita [Biomedical Engineering Graduate Group, Department of Radiology, University of California, Davis, California 95817 (United States); and others

    2014-09-15

    The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important that the medical physics community have the required information to be able to understand, estimate, and communicate the radiation dose levels involved in breast tomosynthesis imaging. For this purpose, the American Association of Physicists in Medicine Task Group 223 on Dosimetry in Tomosynthesis Imaging has prepared this report that discusses dosimetry in breast imaging in general, and describes a methodology and provides the data necessary to estimate mean breast glandular dose from a tomosynthesis acquisition. In an effort to maximize familiarity with the procedures and data provided in this Report, the methodology to perform the dose estimation in DBT is based as much as possible on that used in mammography dose estimation.

  18. ESTRO consensus guideline on target volume delineation for elective radiation therapy of early stage breast cancer

    International Nuclear Information System (INIS)

    Offersen, Birgitte V.; Boersma, Liesbeth J.; Kirkove, Carine; Hol, Sandra; Aznar, Marianne C.; Biete Sola, Albert; Kirova, Youlia M.; Pignol, Jean-Philippe; Remouchamps, Vincent; Verhoeven, Karolien; Weltens, Caroline; Arenas, Meritxell; Gabrys, Dorota; Kopek, Neil; Krause, Mechthild; Lundstedt, Dan; Marinko, Tanja

    2015-01-01

    Background and purpose: Delineation of clinical target volumes (CTVs) is a weak link in radiation therapy (RT), and large inter-observer variation is seen in breast cancer patients. Several guidelines have been proposed, but most result in larger CTVs than based on conventional simulator-based RT. The aim was to develop a delineation guideline obtained by consensus between a broad European group of radiation oncologists. Material and methods: During ESTRO teaching courses on breast cancer, teachers sought consensus on delineation of CTV through dialogue based on cases. One teacher delineated CTV on CT scans of 2 patients, followed by discussion and adaptation of the delineation. The consensus established between teachers was sent to other teams working in the same field, both locally and on a national level, for their input. This was followed by developing a broad consensus based on discussions. Results: Borders of the CTV encompassing a 5 mm margin around the large veins, running through the regional lymph node levels were agreed, and for the breast/thoracic wall other vessels were pointed out to guide delineation, with comments on margins for patients with advanced breast cancer. Conclusion: The ESTRO consensus on CTV for elective RT of breast cancer, endorsed by a broad base of the radiation oncology community, is presented to improve consistency

  19. Radiation dosimetry in digital breast tomosynthesis: Report of AAPM Tomosynthesis Subcommittee Task Group 223

    International Nuclear Information System (INIS)

    Sechopoulos, Ioannis; Sabol, John M.; Berglund, Johan; Bolch, Wesley E.; Brateman, Libby; Christodoulou, Emmanuel; Goodsitt, Mitchell; Flynn, Michael; Geiser, William; Kyle Jones, A.; Lo, Joseph Y.; Paul Segars, W.; Maidment, Andrew D. A.; Nishino, Kazuyoshi; Nosratieh, Anita

    2014-01-01

    The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important that the medical physics community have the required information to be able to understand, estimate, and communicate the radiation dose levels involved in breast tomosynthesis imaging. For this purpose, the American Association of Physicists in Medicine Task Group 223 on Dosimetry in Tomosynthesis Imaging has prepared this report that discusses dosimetry in breast imaging in general, and describes a methodology and provides the data necessary to estimate mean breast glandular dose from a tomosynthesis acquisition. In an effort to maximize familiarity with the procedures and data provided in this Report, the methodology to perform the dose estimation in DBT is based as much as possible on that used in mammography dose estimation

  20. Effect of ionizing radiation on in situ Raman scattering and photoluminescence of silica optical fibers

    International Nuclear Information System (INIS)

    Bilodeau, T.G.; Ewing, K.J.; Nau, G.M.; Aggarwal, I.D.

    1995-01-01

    Raman fiber optic chemical sensors provide remote situ characterization capability. One application of Raman fiber optic chemical sensors is the characterization of the contents of nuclear waste tanks. In these tanks it is expected that approximately 20 meters of optical fiber will be exposed to radiation levels between 100 and 1,000 rads/hour. In support of this work two silica optical fiber types (one a communications grade fiber and the other nominally radiation resistant) have been tested at the radiation levels expected in the tanks. Luminescence and Raman scattering measurements have been performed in situ with 488-nm excitation on two types of silica optical fiber exposed to a constant low to moderate dose rate of gamma radiation of 880 rads(Si)/hour from a 60 Co source for a total dose of greater than 45 krads. The nominally radiation-resistant fiber was also excited with 514.5-nm and near-infrared 830-nm laser radiation. The rate of the silica Raman signal decrease is more than three times greater for the visible excitation wavelengths than for the 830-nm excitation for the radiation resistant fiber. The behavior of the 650-nm photoluminescence line upon irradiation was different for the two fibers studied, both in terms of the shift of the 650-nm line and rate of increase of the normalized photoluminescence intensity. In all cases the photoluminescence from the fibers was less than the Raman intensity. No radioluminescence was observed in either fiber. The radiation resistant fiber exhibited photo bleaching effects on the Raman transmission when photoannealed with 488-nm laser light

  1. Effect of ionizing radiation on in situ Raman scattering and photoluminescence of silica optical fibers

    Science.gov (United States)

    Bilodeau, T. G.; Ewing, K. J.; Nau, G. M.; Aggarwai, I. D.

    1995-02-01

    Raman fiber optic chemical sensors provide remote in situ characterization capability. One application of Raman fiber optic chemical sensors is the characterization of the contents of nuclear waste tanks. In these tanks it is expected that approximately 20 meters of optical fiber will be exposed to radiation levels between 100 and 1000 rads/hour. In support of this work two silica optical fiber types (one a communications grade fiber and the other nominally radiation resistant) have been tested at the radiation levels expected in the tanks. Luminescence and Raman scattering measurements have been performed in situ with 488-nm excitation on two types of silica optical fiber exposed to a constant low to moderate dose rate of gamma radiation of 880 rads(Si)/hour from a /sup 60/Co source for a total dose of greater than 45 krads. The nominally radiation-resistant fiber was also excited with 514.5-nm and near-infrared 830-nm laser radiation. The rate of the silica Raman signal decrease is more than three times greater for the visible excitation wavelengths than for the 830-nm excitation for the radiation resistant fiber. The behavior of the 650-nm photoluminescence line upon irradiation was different for the two fibers studied, both in terms of the shift of the 650-nm line and rate of increase of the normalized photoluminescence intensity. In all cases the photoluminescence from the fibers was less than the Raman intensity. No radioluminescence was observed in either fiber. The radiation resistant fiber exhibited photobleaching effects on the Raman transmission when photoannealed with 488-nm laser light.

  2. Correlation factor analysis between radiation pneumonitis and chemo-radiotherapy in breast cancer patients

    International Nuclear Information System (INIS)

    Li Huiping; Wang Junjie; Ma Liwen; Zhang Shulan; Deng Huijing; Jia Tingzhen

    2004-01-01

    Objective: To investigate the relationship between radiotherapy-induced lung injury and chemotherapy agents as well as other factors. Methods: A total of 85 breast cancer patients received radiotherapy with sequential or concurrent chemotherapy after surgery were analysed for radiation dose, chemotherapy schedule, age, and lung disease history. Results: Five patients had clinical symptoms of radiation pneumonitis, one of them was necessary to treat and 16 patients developed radiological changes (18.8%). Close relationship was noted between incidence of radiation pneumonitis and radiation dose, timing and drugs used in chemotherapy and lung disease history. Conclusion: High irradiation dose, concurrent chemotherapy, and lung disease history can increase the rate of radiotherapy-induced pulmonary injury in breast cancer patients. (authors)

  3. Efficacy of Breast Shielding During CT of the Head

    International Nuclear Information System (INIS)

    Brnic, Z.; Vekic, B.; Hebrang, A.; Anic, P.

    2003-01-01

    The use of computerized tomography (CT) is rapidly increasing in last two decades, and this method has become the major non-natural source of radiation exposure to the population. CT examinations delivers to the patients more radiation than all other imaging techniques, and contribute disproportionately to the collective dose; in Britain it has been estimated that 4% of diagnostic radiology procedures are CT examinations, being responsible for approximately 40% of the total annual collective dose. Breast doses are high in CT examinations with breasts in scanning planes, being not insignificant also when breasts are exposed only to scatter radiation. Breast doses received through scatter radiation during head CT may account for up to one-fifth of an average mammographic dose per one view. Whilst the possibilities of reduction of radiation load to organs lying in CT scanning planes are limited, the tissues outside the primary beam should be protected against scatter whenever it does not sacrifice image quality. Lead shielding results in significant reduction of external scatter to radiosensitive superficial organs in many diagnostic procedures. The published studies of breast shielding against scatter radiation in diagnostic radiology are scanty, only the later one dealing particularly with breast shielding during head CT examination. The aims of this study were to investigate in vivo the levels of breast exposure to scatter radiation in head CT examination and the dependence of breast exposure upon body constitution. We tried to estimate the efficacy of external lead shielding as a mean of breast dose reduction, and to determine how much radiation reaches the organ from outside, in comparison to radiation load caused through internal scatter. We conclude that, although the level of breast radiation exposure during head CT examinations is generally low, shielding of the breasts with lead apron will further reduce the doses. However is the effect of shielding limited

  4. Measurement of x-ray scattering cross sections of hydrogen and helium with synchrotron radiation

    International Nuclear Information System (INIS)

    Ice, G.E.

    1977-01-01

    Total x-ray scattering is a two-electron expectation value. The prominence of the electron correlation effect was demonstrated in recent theoretical work. Only one measurement of x-ray scattering from H 2 has been reported heretofore, nearly fifty years ago. New measurements were carried out using the virtually monochromatic, intense flux of synchrotron radiation in the SSRP EXAFS line. The targets, at 1 atm pressure, were UHP He and ultrapure H 2 that had been passed through a hot Pd--Ag alloy diffusion purifier. The scattered-photon spectra were measured with a Xe-filled proportional counter and fast multichannel analyzer. The incident flux was monitored with a parallel-plate ion chamber, calibrated by direct counting of the absorber-attenuated beam. Measurements were performed at 5, 6, and 7 keV photon energy, as a function of scattering angle (60, 90, and 135 deg) and azimuthal angle (i.e., polarization). The relative total differential photon scattering cross sections for H 2 over the range 3.0 less than or equal to x = 4πsin (theta/2)lambda less than or equal to 5.6 A -1 agree to within approx. 1% with the correlated calculations of Bentley and Stewart. The ratios of measured cross sections for H 2 to those for He at x = 3.0 and 5.6 A -1 agree to within 1% with the ratios of the Bentley--Stewart H 2 cross sections to the correlated wave-function calculations of Brown for He

  5. A new shielding calculation method for X-ray computed tomography regarding scattered radiation.

    Science.gov (United States)

    Watanabe, Hiroshi; Noto, Kimiya; Shohji, Tomokazu; Ogawa, Yasuyoshi; Fujibuchi, Toshioh; Yamaguchi, Ichiro; Hiraki, Hitoshi; Kida, Tetsuo; Sasanuma, Kazutoshi; Katsunuma, Yasushi; Nakano, Takurou; Horitsugi, Genki; Hosono, Makoto

    2017-06-01

    The goal of this study is to develop a more appropriate shielding calculation method for computed tomography (CT) in comparison with the Japanese conventional (JC) method and the National Council on Radiation Protection and Measurements (NCRP)-dose length product (DLP) method. Scattered dose distributions were measured in a CT room with 18 scanners (16 scanners in the case of the JC method) for one week during routine clinical use. The radiation doses were calculated for the same period using the JC and NCRP-DLP methods. The mean (NCRP-DLP-calculated dose)/(measured dose) ratios in each direction ranged from 1.7 ± 0.6 to 55 ± 24 (mean ± standard deviation). The NCRP-DLP method underestimated the dose at 3.4% in fewer shielding directions without the gantry and a subject, and the minimum (NCRP-DLP-calculated dose)/(measured dose) ratio was 0.6. The reduction factors were 0.036 ± 0.014 and 0.24 ± 0.061 for the gantry and couch directions, respectively. The (JC-calculated dose)/(measured dose) ratios ranged from 11 ± 8.7 to 404 ± 340. The air kerma scatter factor κ is expected to be twice as high as that calculated with the NCRP-DLP method and the reduction factors are expected to be 0.1 and 0.4 for the gantry and couch directions, respectively. We, therefore, propose a more appropriate method, the Japanese-DLP method, which resolves the issues of possible underestimation of the scattered radiation and overestimation of the reduction factors in the gantry and couch directions.

  6. Geographic access to radiation therapy facilities and disparities of early-stage breast cancer treatment

    Directory of Open Access Journals (Sweden)

    Yan Lin

    2018-05-01

    Full Text Available Few studies of breast cancer treatment have focused on the Northern Plains of the United States, an area with a high mastectomy rate. This study examined the association between geographic access to radiation therapy facilities and receipt of breast cancer treatments among early-stage breast cancer patients in South Dakota. Based on 4,209 early-stage breast cancer patients diagnosed between 2001 and 2012 in South Dakota, the study measured geographic proximity to radiation therapy facilities using the shortest travel time for patients to the closest radiation therapy facility. Two-level logistic regression models were used to estimate for early stage cases i the odds of mastectomy versus breast conserving surgery (BCS; ii the odds of not receiving radiation therapy after BCS versus receiving follow-up radiation therapy. Covariates included race/ethnicity, age at diagnosis, tumour grade, tumour sequence, year of diagnosis, census tract-level poverty rate and urban/rural residence. The spatial scan statistic method was used to identify geographic areas with significantly higher likelihood of experiencing mastectomy. The study found that geographic accessibility to radiation therapy facilities was negatively associated with the likelihood of receiving mastectomy after adjustment for other covariates, but not associated with radiation therapy use among patients receiving BCS. Compared with patients travelling less than 30 minutes to a radiation therapy facility, patients travelling more than 90 minutes were about 1.5 times more likely to receive mastectomy (odds ratio, 1.51; 95% confidence interval, 1.08-2.11 and patients travelling more than 120 minutes were 1.7 times more likely to receive mastectomy (odds ratio, 1.70; 95% confidence interval, 1.19-2.42. The study also identified a statistically significant cluster of patients receiving mastectomy who were located in south-eastern South Dakota, after adjustment for other factors. Because

  7. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chao-Jen, E-mail: cjlai3711@gmail.com; Zhong, Yuncheng; Yi, Ying; Wang, Tianpeng; Shaw, Chris C. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2015-06-15

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical

  8. Study of the radiation effect in breast implants

    Energy Technology Data Exchange (ETDEWEB)

    Moreno T, L. R.; Ramirez R, A., E-mail: lumor2000@yahoo.com.mx [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Departamento de Ciencias Basicas, Av. San Pablo No. 180, Col. Reynosa Tamaulipas, 02200 Mexico D. F. (Mexico)

    2013-10-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  9. Study of the radiation effect in breast implants

    International Nuclear Information System (INIS)

    Moreno T, L. R.; Ramirez R, A.

    2013-01-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  10. Investigation of Doppler spectra of laser radiation scattered inside hand skin during occlusion test

    Science.gov (United States)

    Kozlov, I. O.; Zherebtsov, E. A.; Zherebtsova, A. I.; Dremin, V. V.; Dunaev, A. V.

    2017-11-01

    Laser Doppler flowmetry (LDF) is a method widely used in diagnosis of microcirculation diseases. It is well known that information about frequency distribution of Doppler spectrum of the laser radiation scattered by moving red blood cells (RBC) usually disappears after signal processing procedure. Photocurrent’s spectrum distribution contains valuable diagnostic information about velocity distribution of the RBC. In this research it is proposed to compute the indexes of microcirculation in the sub-ranges of the Doppler spectrum as well as investigate the frequency distribution of the computed indexes.

  11. Source of X-ray radiation based on back compton scattering

    CERN Document Server

    Bulyak, E V; Karnaukhov, I M; Kononenko, S G; Lapshin, V G; Mytsykov, A O; Telegin, Yu P; Shcherbakov, A A; Zelinsky, Andrey Yurij

    2000-01-01

    Applicability was studied and previous estimation was done of power X-ray beams generation by backward Compton scattering of a laser photon beam on a cooled down electron beam. The few MeV electron beam circulating in a compact storage ring can be cooled down by interaction of that beam with powerful laser radiation of micrometer wavelength to achieve normalized emittance of 10 sup - sup 7 m. A tunable X-ray source of photons of energy ranging from few keV up to a hundred keV could result from the interaction of the laser beam with a dense electron beam.

  12. Source of X-ray radiation based on back compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bulyak, E.V.; Gladkikh, P.I.; Karnaukhov, I.M.; Kononenko, S.G.; Lapshin, V.I.; Mytsykov, A.O.; Telegin, Yu.N.; Shcherbakov, A.A. E-mail: shcherbakov@kipt.kharkov.ua; Zelinsky, A.Yu

    2000-06-21

    Applicability was studied and previous estimation was done of power X-ray beams generation by backward Compton scattering of a laser photon beam on a cooled down electron beam. The few MeV electron beam circulating in a compact storage ring can be cooled down by interaction of that beam with powerful laser radiation of micrometer wavelength to achieve normalized emittance of 10{sup -7} m. A tunable X-ray source of photons of energy ranging from few keV up to a hundred keV could result from the interaction of the laser beam with a dense electron beam.

  13. Source of X-ray radiation based on back compton scattering

    International Nuclear Information System (INIS)

    Bulyak, E.V.; Gladkikh, P.I.; Karnaukhov, I.M.; Kononenko, S.G.; Lapshin, V.I.; Mytsykov, A.O.; Telegin, Yu.N.; Shcherbakov, A.A.; Zelinsky, A.Yu.

    2000-01-01

    Applicability was studied and previous estimation was done of power X-ray beams generation by backward Compton scattering of a laser photon beam on a cooled down electron beam. The few MeV electron beam circulating in a compact storage ring can be cooled down by interaction of that beam with powerful laser radiation of micrometer wavelength to achieve normalized emittance of 10 -7 m. A tunable X-ray source of photons of energy ranging from few keV up to a hundred keV could result from the interaction of the laser beam with a dense electron beam

  14. Density measurement by means of once scattered gamma radiation the ETG probe, principles and equipment

    International Nuclear Information System (INIS)

    Joergensen, J.L.; Oelgaard, P.L.; Berg, F.

    1987-01-01

    The Department of Electrophysics, the Technical University of Denmark, and the Danish National Road Laboratory have together developed a new patent claimed device for measurements of the in situ density of materials. This report describes the principles of the system and some experimental results. The system is based on the once scattered gamma radiation. In a totally non-destructive and fast way it is possible to measure the density of up to 25 cm thick layers. Furthermore, an estimate of the density variation through the layer may be obtained. Thus the gauge represents a new generation of equipment for e.g. compaction control of road constructions. (author)

  15. Nuclear inelastic scattering of synchrotron radiation on solutions of 57Fe complexes

    International Nuclear Information System (INIS)

    Vanko, Gy.; Vertes, A.; Bottyan, L.; Nagy, D.L.; Szilagyi, E.

    2000-01-01

    Nuclear inelastic resonant scattering of synchrotron radiation was applied to the study solutions of 57 Fe complexes. In order to reveal different inelastic contributions solutions of two different 57 Fe complexes of different molecular dimensions with solvents of substantially different viscosities were studied. We argue that the only former experiment available in the literature overestimates the role of the diffusivity in affecting the spectrum. The first direct observation of an intramolecular vibrational transition assisting the nuclear resonance absorption in a liquid is reported. (author)

  16. Electron scattering by an atom in the field of resonant laser radiation

    International Nuclear Information System (INIS)

    Agre, M.; Rapoport, L.

    1982-01-01

    The collision of an electron with an atom in the field of intense electromagnetic radiation that is at resonance with two atomic multiplets is investigated theoretically. Expressions are obtained for the amplitudes of the elastic and inelastic scattering with emission (absorption) of photons. The case of a ground state at resonance with a doublet is considered in detail. It is shown that photon absorption takes place predominantly in the case of resonance in inelastic transitions from a state of the lower multiplet, and photon emission takes place in transitions from a state of the upper multiplet

  17. Radiation therapy in the management of locally advanced and disseminated breast cancer

    International Nuclear Information System (INIS)

    Chu, F.C.H.

    1980-01-01

    Radiation theraoy should be fully used in the management of advanced breast cancer. Locally advanced primary or recurrent carcinoma, with limited extent, should be treated aggressively, aimed at permanent control. Palliative treatment of incurable or metastatic lesions relieves symptoms and improves patient's quality of survival. Some metastatic lesions involving vital structures may create emergencies. Prompt institution of radiation therapy may reverse the serious complication and save the patient's life

  18. Radiation induced esophageal adenocarcinoma in a woman previously treated for breast cancer and renal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Raissouni Soundouss

    2012-08-01

    Full Text Available Abstract Background Secondary radiation-induced cancers are rare but well-documented as long-term side effects of radiation in large populations of breast cancer survivors. Multiple neoplasms are rare. We report a case of esophageal adenocarcinoma in a patient treated previously for breast cancer and clear cell carcinoma of the kidney. Case presentation A 56 year-old non smoking woman, with no alcohol intake and no familial history of cancer; followed in the National Institute of Oncology of Rabat Morocco since 1999 for breast carcinoma, presented on consultation on January 2011 with dysphagia. Breast cancer was treated with modified radical mastectomy, 6 courses of chemotherapy based on CMF regimen and radiotherapy to breast, inner mammary chain and to pelvis as castration. Less than a year later, a renal right mass was discovered incidentally. Enlarged nephrectomy realized and showed renal cell carcinoma. A local and metastatic breast cancer recurrence occurred in 2007. Patient had 2 lines of chemotherapy and 2 lines of hormonotherapy with Letrozole and Tamoxifen assuring a stable disease. On January 2011, the patient presented dysphagia. Oesogastric endoscopy showed middle esophagus stenosing mass. Biopsy revealed adenocarcinoma. No evidence of metastasis was noticed on computed tomography and breast disease was controlled. Palliative brachytherapy to esophagus was delivered. Patient presented dysphagia due to progressive disease 4 months later. Jejunostomy was proposed but the patient refused any treatment. She died on July 2011. Conclusion We present here a multiple neoplasm in a patient with no known family history of cancers. Esophageal carcinoma is most likely induced by radiation. However the presence of a third malignancy suggests the presence of genetic disorders.

  19. Radiation induced esophageal adenocarcinoma in a woman previously treated for breast cancer and renal cell carcinoma.

    Science.gov (United States)

    Raissouni, Soundouss; Raissouni, Ferdaous; Rais, Ghizlane; Aitelhaj, Meryem; Lkhoyaali, Siham; Latib, Rachida; Mohtaram, Amina; Rais, Fadoua; Mrabti, Hind; Kabbaj, Nawal; Amrani, Naima; Errihani, Hassan

    2012-08-09

    Secondary radiation-induced cancers are rare but well-documented as long-term side effects of radiation in large populations of breast cancer survivors. Multiple neoplasms are rare. We report a case of esophageal adenocarcinoma in a patient treated previously for breast cancer and clear cell carcinoma of the kidney. A 56 year-old non smoking woman, with no alcohol intake and no familial history of cancer; followed in the National Institute of Oncology of Rabat Morocco since 1999 for breast carcinoma, presented on consultation on January 2011 with dysphagia. Breast cancer was treated with modified radical mastectomy, 6 courses of chemotherapy based on CMF regimen and radiotherapy to breast, inner mammary chain and to pelvis as castration. Less than a year later, a renal right mass was discovered incidentally. Enlarged nephrectomy realized and showed renal cell carcinoma. A local and metastatic breast cancer recurrence occurred in 2007. Patient had 2 lines of chemotherapy and 2 lines of hormonotherapy with Letrozole and Tamoxifen assuring a stable disease. On January 2011, the patient presented dysphagia. Oesogastric endoscopy showed middle esophagus stenosing mass. Biopsy revealed adenocarcinoma. No evidence of metastasis was noticed on computed tomography and breast disease was controlled. Palliative brachytherapy to esophagus was delivered. Patient presented dysphagia due to progressive disease 4 months later. Jejunostomy was proposed but the patient refused any treatment. She died on July 2011. We present here a multiple neoplasm in a patient with no known family history of cancers. Esophageal carcinoma is most likely induced by radiation. However the presence of a third malignancy suggests the presence of genetic disorders.

  20. Computation of the glandular radiation dose in digital tomosynthesis of the breast

    International Nuclear Information System (INIS)

    Sechopoulos, Ioannis; Suryanarayanan, Sankararaman; Vedantham, Srinivasan; D'Orsi, Carl; Karellas, Andrew

    2007-01-01

    Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose (D g N) to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x-ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the D g N to the breast tissue was computed for varying x-ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio-caudal (CC) and medio-lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammographic energies, the RGD was found to have a weak dependence on glandular fraction and x-ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided

  1. Muscular pseudotumor of the breast following doxorubicin and radiation therapy for oat cell carcinoma of the lung

    International Nuclear Information System (INIS)

    Wergowske, G.; Chang, J.C.; Marger, D.

    1982-01-01

    Two male patients developed muscular pseudotumor of the breast following combined treatment of radiation and chemotherapy with cyclophosphamide, doxorubicin, methotrexate and procarbazine for oat cell carcinoma of the lung. The pathologic findings of the biopsy specimens revealed muscle and capillary changes similar to previously reported myocardiotoxicity from doxorubicin and radiation therapy. Discussed is a possible additive or synergistic toxic effect of doxorubicin and radiation therapy in the development of muscular pseudotumor of the breast

  2. Breast Cancer Risk After Radiation Therapy for Hodgkin Lymphoma : Influence of Gonadal Hormone Exposure

    NARCIS (Netherlands)

    Krul, Inge M; Opstal-van Winden, Annemieke W J; Aleman, Berthe M P; Janus, Cécile P M; van Eggermond, Anna M; De Bruin, Marie L; Hauptmann, Michael; Krol, Augustinus D G; Schaapveld, Michael; Broeks, Annegien; Kooijman, Karen R; Fase, Sandra; Lybeert, Marnix L; Zijlstra, Josée M; van der Maazen, Richard W M; Kesminiene, Ausrele; Diallo, Ibrahima; de Vathaire, Florent; Russell, Nicola S; van Leeuwen, Flora E

    2017-01-01

    BACKGROUND: Young women treated with chest radiation therapy (RT) for Hodgkin lymphoma (HL) experience a strongly increased risk of breast cancer (BC). It is unknown whether endogenous and exogenous gonadal hormones affect RT-associated BC risk. METHODS: We conducted a nested case-control study

  3. The breast cancer patient's experience of making radiation therapy treatment decisions

    International Nuclear Information System (INIS)

    Halkett, Georgia; Scutter, Sheila; Arbon, Paul; Borg, Martin

    2005-01-01

    Women who are diagnosed with breast cancer have many decisions to make during the course of their treatment. The aims of this paper are to describe the women's experience of making radiation therapy treatment decisions for early breast cancer and to explore how women feel about receiving radiation therapy. An in-depth understanding of the women's experience was developed using a qualitative research approach underpinned by hermeneutic phenomenology. In-depth interviews were conducted with 18 women who had completed treatment for early breast cancer. The themes that emerged from the data were: being challenged, getting ready, beyond control, regaining a sense of control and getting through it. This study provides health professionals with an initial understanding of the women's perspective of the experience of making radiation therapy treatment decisions for early breast cancer. This study concludes by suggesting that further research needs to be conducted to gain an understanding of how other patients feel about treatment decision making and radiation therapy. Copyright (2005) Australian Institute of Radiography

  4. Experimental researches of nuclear reactor neutron and gamma radiation scattering into the atmosphere

    International Nuclear Information System (INIS)

    Istomin, Yu.L.; Zelensky, D.I.; Cherepnin, Yu.S.; Orlov, Yu.V.; Netecha, M.E.; Avaev, V.N.; Vasel'ev, G.A.; Sakamoto, H.; Nomura, Y.; Naito, Y.

    1998-01-01

    In the report there are results of measuring radiation distribution on the caps of the RA and IWG.1M research reactors. Comparative analysis of the results is also in the report. There are neutron spectra in the interval of energies from 10 -9 to 13 MeV above RA and IWG.1M reactors. The spectra were measured with a set of activation detectors. Measurements were calculated to a nominal rate: for RA reactor - 300 kw, for IWG.1M - 7 MW. Thus, in the course of the experiment, vast experimental information relating to distribution of the RA and IWG.1M reactor gamma and neutron radiation scattered in the air for distances varying from 50 to 1000 m from the reactors has become available. The data obtained are to be used to verify the calculation codes and to validate the group nuclear constants

  5. Radiation pressure in galactic disks: stability, turbulence, and winds in the single-scattering limit

    Science.gov (United States)

    Wibking, Benjamin D.; Thompson, Todd A.; Krumholz, Mark R.

    2018-04-01

    The radiation force on dust grains may be dynamically important in driving turbulence and outflows in rapidly star-forming galaxies. Recent studies focus on the highly optically-thick limit relevant to the densest ultra-luminous galaxies and super star clusters, where reprocessed infrared photons provide the dominant source of electromagnetic momentum. However, even among starburst galaxies, the great majority instead lie in the so-called "single-scattering" limit, where the system is optically-thick to the incident starlight, but optically-thin to the re-radiated infrared. In this paper we present a stability analysis and multidimensional radiation-hydrodynamic simulations exploring the stability and dynamics of isothermal dusty gas columns in this regime. We describe our algorithm for full angle-dependent radiation transport based on the discontinuous Galerkin finite element method. For a range of near-Eddington fluxes, we show that the medium is unstable, producing convective-like motions in a turbulent atmosphere with a scale height significantly inflated compared to the gas pressure scale height and mass-weighted turbulent energy densities of ˜0.01 - 0.1 of the midplane radiation energy density, corresponding to mass-weighted velocity dispersions of Mach number ˜0.5 - 2. Extrapolation of our results to optical depths of 103 implies maximum turbulent Mach numbers of ˜20. Comparing our results to galaxy-averaged observations, and subject to the approximations of our calculations, we find that radiation pressure does not contribute significantly to the effective supersonic pressure support in star-forming disks, which in general are substantially sub-Eddington. We further examine the time-averaged vertical density profiles in dynamical equilibrium and comment on implications for radiation-pressure-driven galactic winds.

  6. Radiation Therapy in Treating Post-Menopausal Women With Early Stage Breast Cancer Undergoing Surgery

    Science.gov (United States)

    2017-06-07

    Ductal Breast Carcinoma In Situ; Estrogen Receptor Negative; Estrogen Receptor Positive; HER2/Neu Negative; Invasive Cribriform Breast Carcinoma; Invasive Ductal Carcinoma, Not Otherwise Specified; Lobular Breast Carcinoma In Situ; Mucinous Breast Carcinoma; Papillary Breast Carcinoma; Progesterone Receptor Positive; Stage I Breast Cancer; Stage II Breast Cancer; Stage IIIA Breast Cancer; Stage IIIC Breast Cancer; Tubular Breast Carcinoma

  7. Bioavailable serum estradiol may alter radiation risk of postmenopausal breast cancer: a nested case-control study.

    Science.gov (United States)

    Grant, Eric J; Cologne, John B; Sharp, Gerald B; Eguchi, Hidetaka; Stevens, Richard G; Izumi, Shizue; Kim, Young-Min; Berrington de González, Amy; Ohishi, Waka; Nakachi, Kei

    2018-02-01

    Ionizing radiation and high levels of circulating estradiol are known breast cancer carcinogens. We investigated the risk of first primary postmenopausal breast cancer in relation to the combined effects of whole-body ionizing radiation exposure and prediagnostic levels of postmenopausal sex hormones, particularly bioavailable estradiol (bE 2 ). A nested case-control study of 57 incident breast cancer cases matched with 110 controls among atomic bomb survivors. Joint effects of breast radiation dose and circulating levels of sex hormones were assessed using binary regression and path analysis. Radiation exposure, higher levels of bE 2 , testosterone and progesterone, and established reproductive risk factors were positively associated with postmenopausal breast cancer risk. A test for mediation of the effect of radiation via bE 2 level suggested a small (14%) but significant mediation (p = 0.004). The estimated interaction between radiation and bE 2 was large but not significant (interaction = 3.86; p = 0.32). There is accumulating evidence that ionizing radiation not only damages DNA but also alters other organ systems. While caution is needed, some portion of the radiation risk of postmenopausal breast cancer appeared to be mediated through bE 2 levels, which may be evidence for cancer risks due to both direct and indirect effects of radiation.

  8. Analysis of light scattering from human breast tissue using a custom dual-optical scanning near-field optical microscope.

    Science.gov (United States)

    Kyle, Jennifer Reiber; Kyle, Michael D; Raghavan, Ravi; Budak, Gurer; Ozkan, Cengiz S; Ozkan, Mihrimah

    2011-03-01

    In this paper we introduce a custom scanning near-field optical microscope (SNOM) that simultaneously collects reflection and transmission near-field images along with topography. This dual-optical SNOM uses a bent probe, which allows for axial reflection imaging, accurate surface scanning, and easy identification of topographic artifacts. Using this novel dual-optical SNOM, we image desiccated and non-desiccated human breast epithelial tissue. By comparing the simultaneous SNOM images, we isolate the effects of tissue morphology and variations in refractive indices on the forward- and back-scattering of light from the tissue. We find that the reduction in back-scattering from tissue, relative to the glass slide, is caused by dense packing of the scattering sites in the cytoplasm (morphology) in the desiccated tissue and a thin-film of water adhering to the glass slide (refractive index) in the non-desiccated tissue sample. Our work demonstrates the potential of our customized dual-optical SNOM system for label-free tissue diagnostics. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. LASER RADIATION CHARACTERISTICS (BRIEF COMMUNICATIONS): Conversion of KrCl and XeCl laser radiation to the visible spectral range by stimulated Raman scattering in lead vapor

    Science.gov (United States)

    Evtushenko, Gennadii S.; Mel'chenko, S. V.; Panchenko, Aleksei N.; Tarasenko, Viktor F.

    1990-04-01

    Conversion of KrCl and XeCl laser radiation by stimulated Raman scattering was achieved in lead vapor. The KrCl laser radiation was converted into three lines in the visible region at λ = 406, 590, and 723 nm by transitions from both the ground and first excited levels of the lead atom. The conversion efficiency of XeCl laser radiation of low spatial coherence was found to be limited by the activation of a competing nonlinear process.

  10. Relationship between the Kubelka-Munk scattering and radiative transfer coefficients.

    Science.gov (United States)

    Thennadil, Suresh N

    2008-07-01

    The relationship between the Kubelka-Munk (K-M) and the transport scattering coefficient is obtained through a semi-empirical approach. This approach gives the same result as that given by Gate [Appl. Opt.13, 236 (1974)] when the incident beam is diffuse. This result and those given by Star et al. [Phys. Med. Biol.33, 437 (1988)] and Brinkworth [Appl. Opt.11, 1434 (1972)] are compared with the exact solution of the radiative transfer equation over a large range of optical properties. It is found that the latter expressions, which include an absorption component, do not give accurate results over the range considered. Using the semi-empirical approach, the relationship between the K-M and the transport scattering coefficient is derived for the case where the incident light is collimated. It is shown that although the K-M equation is derived based on diffuse incident light, it can also represent very well the reflectance from a slab of infinite thickness when the incident light is collimated. However, in this case the relationship between the coefficients has to include a function that is dependent on the anisotropy factor. Analysis indicates that the K-M transform achieves the objective of obtaining a measure that gives the ratio of absorption to scattering effects for both diffuse and collimated incident beams over a large range of optical properties.

  11. A MULTIPLE SCATTERING POLARIZED RADIATIVE TRANSFER MODEL: APPLICATION TO HD 189733b

    Energy Technology Data Exchange (ETDEWEB)

    Kopparla, Pushkar; Yung, Yuk L. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA (United States); Natraj, Vijay; Swain, Mark R. [Jet Propulsion Laboratory (NASA-JPL), Pasadena, CA (United States); Zhang, Xi [Lunar and Planetary Laboratory, University of Arizona, Tucson, AZ (United States); Wiktorowicz, Sloane J., E-mail: pkk@gps.caltech.edu [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA (United States)

    2016-01-20

    We present a multiple scattering vector radiative transfer model that produces disk integrated, full phase polarized light curves for reflected light from an exoplanetary atmosphere. We validate our model against results from published analytical and computational models and discuss a small number of cases relevant to the existing and possible near-future observations of the exoplanet HD 189733b. HD 189733b is arguably the most well observed exoplanet to date and the only exoplanet to be observed in polarized light, yet it is debated if the planet’s atmosphere is cloudy or clear. We model reflected light from clear atmospheres with Rayleigh scattering, and cloudy or hazy atmospheres with Mie and fractal aggregate particles. We show that clear and cloudy atmospheres have large differences in polarized light as compared to simple flux measurements, though existing observations are insufficient to make this distinction. Futhermore, we show that atmospheres that are spatially inhomogeneous, such as being partially covered by clouds or hazes, exhibit larger contrasts in polarized light when compared to clear atmospheres. This effect can potentially be used to identify patchy clouds in exoplanets. Given a set of full phase polarimetric measurements, this model can constrain the geometric albedo, properties of scattering particles in the atmosphere, and the longitude of the ascending node of the orbit. The model is used to interpret new polarimetric observations of HD 189733b in a companion paper.

  12. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography.

    Science.gov (United States)

    Platten, David John

    2014-06-01

    Existing data used to calculate the barrier transmission of scattered radiation from computed tomography (CT) are based on primary beam CT energy spectra. This study uses the EGSnrc Monte Carlo system and Epp user code to determine the energy spectra of CT scatter from four different primary CT beams passing through an ICRP 110 male reference phantom. Each scatter spectrum was used as a broad-beam x-ray source in transmission simulations through seventeen thicknesses of lead (0.00-3.50 mm). A fit of transmission data to lead thickness was performed to obtain α, β and γ parameters for each spectrum. The mean energy of the scatter spectra were up to 12.3 keV lower than that of the primary spectrum. For 120 kVp scatter beams the transmission through lead was at least 50% less than predicted by existing data for thicknesses of 1.5 mm and greater; at least 30% less transmission was seen for 140 kVp scatter beams. This work has shown that the mean energy and half-value layer of CT scatter spectra are lower than those of the corresponding primary beam. The transmission of CT scatter radiation through lead is lower than that calculated with currently available data. Using the data from this work will result in less lead shielding being required for CT scanner installations.

  13. Feasibility and Acute Toxicity of Hypofractionated Radiation in Large-breasted Patients

    Energy Technology Data Exchange (ETDEWEB)

    Dorn, Paige L., E-mail: pdorn@radonc.uchicago.edu [Department of Radiation and Cellular Oncology, University of Chicago Hospitals, Chicago, IL (United States); Corbin, Kimberly S.; Al-Hallaq, Hania; Hasan, Yasmin; Chmura, Steven J. [Department of Radiation and Cellular Oncology, University of Chicago Hospitals, Chicago, IL (United States)

    2012-05-01

    Purpose: To determine the feasibility of and acute toxicity associated with hypofractionated whole breast radiation (HypoRT) after breast-conserving surgery in patients excluded from or underrepresented in randomized trials comparing HypoRT with conventional fractionation schedules. Methods and Materials: A review was conducted of all patients consecutively treated with HypoRT at University of Chicago. All patients were treated to 42.56 Gy in 2.66 Gy daily fractions in either the prone or supine position. Planning was performed in most cases using wedges and large segments or a 'field-in-field' technique. Breast volume was estimated using volumetric measurements of the planning target volume (PTV). Dosimetric parameters of heterogeneity (V105, V107, V110, and maximum dose) were recorded for each treatment plan. Acute toxicity was scored for each treated breast. Results: Between 2006 and 2010, 78 patients were treated to 80 breasts using HypoRT. Most women were overweight or obese (78.7%), with a median body mass index of 29.2 kg/m{sup 2}. Median breast volume was 1,351 mL. Of the 80 treated breasts, the maximum acute skin toxicity was mild erythema or hyperpigmentation in 70.0% (56/80), dry desquamation in 21.25% (17/80), and focal moist desquamation in 8.75% (7/80). Maximum acute toxicity occurred after the completion of radiation in 31.9% of patients. Separation >25 cm was not associated with increased toxicity. Breast volume was the only patient factor significantly associated with moist desquamation on multivariable analysis (p = 0.01). Patients with breast volume >2,500 mL experienced focal moist desquamation in 27.2% of cases compared with 6.34% in patients with breast volume <2,500 mL (p = 0.03). Conclusions: HypoRT is feasible and safe in patients with separation >25 cm and in patients with large breast volume when employing modern planning and positioning techniques. We recommend counseling regarding expected increases in skin toxicity in women

  14. Feasibility and Acute Toxicity of Hypofractionated Radiation in Large-breasted Patients

    International Nuclear Information System (INIS)

    Dorn, Paige L.; Corbin, Kimberly S.; Al-Hallaq, Hania; Hasan, Yasmin; Chmura, Steven J.

    2012-01-01

    Purpose: To determine the feasibility of and acute toxicity associated with hypofractionated whole breast radiation (HypoRT) after breast-conserving surgery in patients excluded from or underrepresented in randomized trials comparing HypoRT with conventional fractionation schedules. Methods and Materials: A review was conducted of all patients consecutively treated with HypoRT at University of Chicago. All patients were treated to 42.56 Gy in 2.66 Gy daily fractions in either the prone or supine position. Planning was performed in most cases using wedges and large segments or a “field-in-field” technique. Breast volume was estimated using volumetric measurements of the planning target volume (PTV). Dosimetric parameters of heterogeneity (V105, V107, V110, and maximum dose) were recorded for each treatment plan. Acute toxicity was scored for each treated breast. Results: Between 2006 and 2010, 78 patients were treated to 80 breasts using HypoRT. Most women were overweight or obese (78.7%), with a median body mass index of 29.2 kg/m 2 . Median breast volume was 1,351 mL. Of the 80 treated breasts, the maximum acute skin toxicity was mild erythema or hyperpigmentation in 70.0% (56/80), dry desquamation in 21.25% (17/80), and focal moist desquamation in 8.75% (7/80). Maximum acute toxicity occurred after the completion of radiation in 31.9% of patients. Separation >25 cm was not associated with increased toxicity. Breast volume was the only patient factor significantly associated with moist desquamation on multivariable analysis (p = 0.01). Patients with breast volume >2,500 mL experienced focal moist desquamation in 27.2% of cases compared with 6.34% in patients with breast volume 25 cm and in patients with large breast volume when employing modern planning and positioning techniques. We recommend counseling regarding expected increases in skin toxicity in women with a PTV volume >2,500 mL.

  15. Unique proteomic signature for radiation sensitive patients; a comparative study between normo-sensitive and radiation sensitive breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Skiöld, Sara [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden); Azimzadeh, Omid [Institute of Radiation Biology, German Research Center for Environmental Health, Helmholtz Zentrum München (Germany); Merl-Pham, Juliane [Research Unit Protein Science, German Research Center for Environmental Health, Helmholtz Zentrum München, Neuherberg (Germany); Naslund, Ingemar; Wersall, Peter; Lidbrink, Elisabet [Division of Radiotherapy, Radiumhemmet, Karolinska University Hospital, Stockholm (Sweden); Tapio, Soile [Institute of Radiation Biology, German Research Center for Environmental Health, Helmholtz Zentrum München (Germany); Harms-Ringdahl, Mats [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden); Haghdoost, Siamak, E-mail: Siamak.Haghdoost@su.se [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden)

    2015-06-15

    Highlights: • The unique protein expression profiles were found that separate radiosensitive from normal sensitive breast cancer patients. • The oxidative stress response, coagulation properties and acute phase response suggested to be the hallmarks of radiation sensitivity. - Abstract: Radiation therapy is a cornerstone of modern cancer treatment. Understanding the mechanisms behind normal tissue sensitivity is essential in order to minimize adverse side effects and yet to prevent local cancer reoccurrence. The aim of this study was to identify biomarkers of radiation sensitivity to enable personalized cancer treatment. To investigate the mechanisms behind radiation sensitivity a pilot study was made where eight radiation-sensitive and nine normo-sensitive patients were selected from a cohort of 2914 breast cancer patients, based on acute tissue reactions after radiation therapy. Whole blood was sampled and irradiated in vitro with 0, 1, or 150 mGy followed by 3 h incubation at 37 °C. The leukocytes of the two groups were isolated, pooled and protein expression profiles were investigated using isotope-coded protein labeling method (ICPL). First, leukocytes from the in vitro irradiated whole blood from normo-sensitive and extremely sensitive patients were compared to the non-irradiated controls. To validate this first study a second ICPL analysis comparing only the non-irradiated samples was conducted. Both approaches showed unique proteomic signatures separating the two groups at the basal level and after doses of 1 and 150 mGy. Pathway analyses of both proteomic approaches suggest that oxidative stress response, coagulation properties and acute phase response are hallmarks of radiation sensitivity supporting our previous study on oxidative stress response. This investigation provides unique characteristics of radiation sensitivity essential for individualized radiation therapy.

  16. Unique proteomic signature for radiation sensitive patients; a comparative study between normo-sensitive and radiation sensitive breast cancer patients

    International Nuclear Information System (INIS)

    Skiöld, Sara; Azimzadeh, Omid; Merl-Pham, Juliane; Naslund, Ingemar; Wersall, Peter; Lidbrink, Elisabet; Tapio, Soile; Harms-Ringdahl, Mats; Haghdoost, Siamak

    2015-01-01

    Highlights: • The unique protein expression profiles were found that separate radiosensitive from normal sensitive breast cancer patients. • The oxidative stress response, coagulation properties and acute phase response suggested to be the hallmarks of radiation sensitivity. - Abstract: Radiation therapy is a cornerstone of modern cancer treatment. Understanding the mechanisms behind normal tissue sensitivity is essential in order to minimize adverse side effects and yet to prevent local cancer reoccurrence. The aim of this study was to identify biomarkers of radiation sensitivity to enable personalized cancer treatment. To investigate the mechanisms behind radiation sensitivity a pilot study was made where eight radiation-sensitive and nine normo-sensitive patients were selected from a cohort of 2914 breast cancer patients, based on acute tissue reactions after radiation therapy. Whole blood was sampled and irradiated in vitro with 0, 1, or 150 mGy followed by 3 h incubation at 37 °C. The leukocytes of the two groups were isolated, pooled and protein expression profiles were investigated using isotope-coded protein labeling method (ICPL). First, leukocytes from the in vitro irradiated whole blood from normo-sensitive and extremely sensitive patients were compared to the non-irradiated controls. To validate this first study a second ICPL analysis comparing only the non-irradiated samples was conducted. Both approaches showed unique proteomic signatures separating the two groups at the basal level and after doses of 1 and 150 mGy. Pathway analyses of both proteomic approaches suggest that oxidative stress response, coagulation properties and acute phase response are hallmarks of radiation sensitivity supporting our previous study on oxidative stress response. This investigation provides unique characteristics of radiation sensitivity essential for individualized radiation therapy

  17. Plasma scattering measurement using a submillimeter wave gyrotron as a radiation source

    International Nuclear Information System (INIS)

    Ogawa, I.; Idehara, T.; Itakura, Y.; Myodo, M.; Hori, T.; Hatae, T.

    2004-01-01

    Plasma scattering measurement is an effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the intensity of a probe beam. A well-collimated, submillimeter wave beam is suitable for improving the spatial and wave number resolutions. Application of high frequency gyrotron is effective in improving the S/N ratio of the measurement because of its capacity to deliver high power. Unlike the molecular vapor lasers, the gyrotrons generate diverging beam of radiation with TE mn mode structure. It is therefore necessary to convert the output radiation into a Gaussian beam. A quasi-optical antenna is a suitable element for the conversion system under consideration since it is applicable to several TE 0n and TE 1n modes. In order to apply the gyrotron to plasma scattering measurement, we have stabilized the output (P = 110 W, f = 354 GHz) of gyrotron up to the level (ΔP/P < 1 %, Δf< 10 kHz). The gyrotron output can be stabilized by decreasing the fluctuation of the cathode potential. (authors)

  18. Electromagnetic scattering and radiation from microstrip patch antennas and spirals residing in a cavity

    Science.gov (United States)

    Volakis, J. L.; Gong, J.; Alexanian, A.; Woo, A.

    1992-01-01

    A new hybrid method is presented for the analysis of the scattering and radiation by conformal antennas and arrays comprised of circular or rectangular elements. In addition, calculations for cavity-backed spiral antennas are given. The method employs a finite element formulation within the cavity and the boundary integral (exact boundary condition) for terminating the mesh. By virtue of the finite element discretization, the method has no restrictions on the geometry and composition of the cavity or its termination. Furthermore, because of the convolutional nature of the boundary integral and the inherent sparseness of the finite element matrix, the storage requirement is kept very low at O(n). These unique features of the method have already been exploited in other scattering applications and have permitted the analysis of large-size structures with remarkable efficiency. In this report, we describe the method's formulation and implementation for circular and rectangular patch antennas in different superstrate and substrate configurations which may also include the presence of lumped loads and resistive sheets/cards. Also, various modelling approaches are investigated and implemented for characterizing a variety of feed structures to permit the computation of the input impedance and radiation pattern. Many computational examples for rectangular and circular patch configurations are presented which demonstrate the method's versatility, modeling capability and accuracy.

  19. X-ray spectral determination by detection of radiation scattered at different angles

    International Nuclear Information System (INIS)

    Barrea, Raul; Mainardi, R.T.

    1987-01-01

    A precise knowledge of the spectral content of an X-ray beam is of fundamental importance in areas such as X-ray fluorescence analysis by absolute methods, radiodiagnosis, radiotherapy, computed tomography, etc. A simple practical method was developed to determine X-ray spectra emitted by X-ray tubes. It is based on the scattering of the beam on a solid target and detection of this radiation at different angles. This methodology can easily be adapted to the successive attenuation of the beam procedure. Numerical parameter values of a proposed analytical function for the energy spectrum are found measuring the radiation intensity with a suitable detector (ionization chamber or plastic scintillation detector) and equating it with the convolution integral of the proposed spectrum with the incoherent scattering function. This procedure of spectra determination is enclosed in the same group of those generically referred as successive modifications of the irradiation set up used in absolute methods of X-ray fluorescence analysis. (Author) [es

  20. Quantum theory of the laser radiation scattering by electrons in magnetic fields

    International Nuclear Information System (INIS)

    Rochlin, H.

    1981-08-01

    A system composed of an electron in a static magnetic field interacting with the quantized electromagnetic field, within the electric-dipole and the nonrelativistic approximations (with a cutoff in momentum space) is considered. The Heisenberg equations are solved exactly and the time evolution of the electric field is determined. This result is then used to obtain the spectrum of the scattered radiation when the initial state of the field is coherent, aplying the theory of photodetection. This theory is thoroughly discussed. Several expressions proposed in the literature for the time-dependent spectrum are compared and conditions for the equivalence of these expressions are analyzed. Moreover, inaccuracies in previous treatments of the theory of photodetection are corrected. The results allow the line shape of the scattered radiation to be analyzed for magnetic fields up to 10 12 G. The quantization of the eletromagnetic field allows one to consider the role of the natural line width, which becomes important near ressonance. In particular, it is analyzed the dependence of the line width with the magnetic field. This treatment includes the renormalization of the electron mass, which keeps the results finite when the cutoff goes to infinity. (Author) [pt

  1. Radiation and scattering from cylindrically conformal printed antennas. Ph.D. Thesis Final Report

    Science.gov (United States)

    Kempel, Leo C.; Volakis, John L.

    1994-01-01

    Microstrip patch antennas offer considerable advantages in terms of weight, aerodynamic drag, cost, flexibility, and observables over more conventional protruding antennas. These flat patch antennas were first proposed over thirty years ago by Deschamps in the United States and Gutton and Baisinot in France. Such antennas have been analyzed and developed for planar as well as curved platforms. However, the methods used in these designs employ gross approximations, suffer from extreme computational burden, or require expensive physical experiments. The goal of this thesis is to develop accurate and efficient numerical modeling techniques which represent actual antenna structures mounted on curved surfaces with a high degree of fidelity. In this thesis, the finite element method is extended to cavity-backed conformal antenna arrays embedded in a circular, metallic, infinite cylinder. Both the boundary integral and absorbing boundary mesh closure conditions will be used for terminating the mesh. These two approaches will be contrasted and used to study the scattering and radiation behavior of several useful antenna configurations. An important feature of this study will be t