WorldWideScience

Sample records for scanning liver ultrasonography

  1. Predictive value of excretory urography, ultrasonography, computerized tomography, and liver and bone scan in the staging of bilharzial bladder cancer in Saudi Arabia

    International Nuclear Information System (INIS)

    Hanash, K.A.; Bissada, N.K.; Abla, A.; Esmail, D.; Dowling, A.

    1984-01-01

    The role of ultrasonography, computed tomography (CT), and radioisotopic scanning in the staging of bilharzial bladder cancer has not been reported previously. Forty patients with invasive bladder cancer seen at the King Faisal Specialist Hospital and Research Centre between January 1978 and June 1981 underwent complete preoperative workup for staging of their tumors prior to radical cystectomy. The preoperative radiologic investigations included excretory urography (IVP), ultrasonography (US), CT of the pelvis, and liver and bone scans. The results of these investigations were compared with the operative and pathologic staging. Ninety-three percent of the patients with bilharzial cancer had evidence of ureteric obstruction on IVP compared with 22% of the nonbilharzial cancer patients. The presence of ureteric obstruction in these patients did not correlate with the stage of the disease with 83% of the patients with superficial tumors (T1 and T2) having hydroureteronephrosis. Ultrasonography and CT had an 83% accuracy in the staging of superficial tumors. Stage T3 tumors were understaged in 14% of the cases. Ultrasonography did not differentiate Stages T3 and T4 tumors while CT scan differentiated these two stages in 57% of the cases. Bone scan failed to reveal evidence of metastatic disease in any of the bilharzial cancer patients. Liver scan was suspicious for liver metastases in two patients with bilharzial cancers in whom open liver biopsy revealed only hepatic bilharziasis. Of all the radiographic studies, US or preferably CT scan seem to be of some value in the staging of bilharzial tumors localized to the bladder. Bone and liver scans are probably of no cost effective benefit

  2. Value of gallbladder B-scan ultrasonography.

    Science.gov (United States)

    Tabrisky, J; Lindstrom, R R; Herman, M W; Castagna, J; Sarti, D

    1975-05-01

    The gallbladder B-scans of 20 patients who had subsequent surgery were separated into three categories based upon certain sonographic criteria. Our data, in this limited series, revealed gallbladder pathology in each patient who had any one or combination of the following scan characteristics: (1) internal echos, (2) irregular wall, or (3) absence of recognizable gallbladder sonolucency. The category which demonstrated a normal sonographic gallbladder, namely a smooth wall and no internal echos, contained a number of false negatives which proved to have either small stone cholelithiasis or extraphepatic ductal obstruction. Within the described limitations, the B-scan can be a valuable test in confirming the significance of a radiographically nonvisualized gallbladder or in detecting a biliary tract lesion in a patient with a disease entity that precludes radiographic visualization by conventional techniques.

  3. Pictorial essay: B-scan ultrasonography in ocular abnormalities

    International Nuclear Information System (INIS)

    Aironi, VD; Gandage, SG

    2009-01-01

    B-scan ultrasonography (USG) is a simple, noninvasive tool for diagnosing lesions of the posterior segment of the eyeball. Common conditions such as cataract, vitreous degeneration, retinal detachment, ocular trauma, choroidal melanoma, and retinoblastoma can be accurately evaluated with this modality. B-scan USG is cost-effective, which is an important consideration in the rural setting. In addition, it is noninvasive and easily available and the results are reproducible

  4. [Abdominal ultrasonography in patients with diabetes mellitus. Part 1: Liver].

    Science.gov (United States)

    Jenssen, C; Pietsch, C; Gottschalk, U; Barreiros, A P; Teufel, A; Cui, X W; Dietrich, C F

    2015-04-01

    In patients with diabetes mellitus, abdominal ultrasonography is the appropriate diagnostic technique to detect and to follow-up secondary and accompanying diseases of the liver, the kidneys, the pancreas, the gastrointestinal tract and of abdominal vessels. Moreover, pancreatic and hepatic diseases may be realized which are of etiological importance for diabetes mellitus. Based on a systematic survey of the published literature, this review in 3 parts will describe the value of abdominal ultrasonography in patients with diabetes mellitus. Part 1 deals with the diagnostic relevance and particular findings of ultrasonographic methods in hepatic manifestations and complications of diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Paediatric ultrasonography of the liver, hepatobiliary tract and pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, R.R. van, E-mail: r.r.vanrijn@amc.uva.nl [Department of Radiology, Emma Children' s Hospital – Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Nievelstein, R.A.J. [Department of Radiology, Wilhelmina Children' s Hospital – University Medical Center, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-09-15

    In the field of paediatric radiology ultrasonography (US) is the most versatile imaging tool available. Children in general, by virtue of their body composition, are excellent candidates for US exams in whom abdominal anatomy and pathology can be visualised in great detail. The fact that during the US study a clinical history can be obtained strongly adds to the value of the US exam. This does require investment in time and expertise and ideally a paediatric radiologist performing the exam. In this review the role of ultrasonography (US) of the liver, biliary tract and pancreas in children is discussed.

  6. Liver scanning in diffuse liver disease

    International Nuclear Information System (INIS)

    Aiginger, P.; Atefie, K.; Scherak, O.; Wolf, A.; Hoefer, R.; Seyfried, H.

    1975-01-01

    The results of liver scans performed with sup(99m)Tc-sulphur colloid in 169 patients suffering from diffuse liver diseases and in 48 normal controls were evaluated. The patients with reactive hepatitis, acute hepatitis, chronic persistent hepatitis, fatty liver and fibrosis of the liver show only minimal deviations from the scintigraphic pattern. On the contrary, highly increased colloid uptake in the spleen is found in cases of chronic aggressive hepatitis, whilst the intrahepatic distribution of the colloid is approximately normal. In cases of liver cirrhosis, increased colloid uptake is found in the left lobe of the liver as well as in the spleen and in the bone marrow. Either normal findings or cirrhosis-like changes of the colloid distribution are observed in patients with alcoholic hepatitis. (orig.) [de

  7. Characterisation of focal liver lesions with contrast enhanced ultrasonography

    International Nuclear Information System (INIS)

    Dietrich, Christoph F.

    2004-01-01

    Ultrasound contrast agents (USCA) have improved the detection rate of liver tumours in recent years. Conventional ultrasound has been reported to be relatively unreliable in the characterisation of liver tumours. SonoVue [reg] (Bracco Imaging Spa) has been shown to be particularly advantageous in the differentiation of benign and malignant liver tumours and, therefore, possibly represents a new cost-effective competitive alternative to other liver imaging modalities (e.g. computed tomography and magnetic resonance imaging), thus allowing these important technologies to be available for other indications (e.g. brain, thorax). More detailed and specific liver tumour characterisation is possible in about 80% of liver tumours due to typical vascularity and perfusion patterns. The role of USCA for better characterisation, which is possible through the analysis of flow characteristics in real time, places a particular emphasis on agent use. Contrast enhanced real-time imaging techniques with SonoVue [reg] allow real-time analysis of tumour perfusion in patients with liver lesions. Liver tumours known to be hyperperfused in the arterial phase (e.g. focal nodular hyperplasia, hepatocellular adenoma and carcinoma, and hyperperfused metastases) can be better detected and characterised. Hypoperfused tumours (e.g. liver metastases of the gastrointestinal tract) can be recognised in the portal venous phase as less perfused 'black spots'. In this article we discuss liver tumour characterisation by contrast enhanced ultrasonography

  8. Observation of Liver Color Scan

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Y K; Ahn, S B [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1969-09-15

    In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permitted a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscesses, 10 hepatitis and other 13 cases of the liver diseases which were clinically and pathologically diagnosed at Severance Hospital, Yonsei Univ. since Feb. 1969 through Sept. 1969. These scintigrams have been analyzed in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1) Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2) Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3) Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4) The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases (74-95% of all diseased livers). 5) The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6) Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape an margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  9. Observation of Liver Color Scan

    International Nuclear Information System (INIS)

    Choe, Y. K.; Ahn, S. B.

    1969-01-01

    In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permitted a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscesses, 10 hepatitis and other 13 cases of the liver diseases which were clinically and pathologically diagnosed at Severance Hospital, Yonsei Univ. since Feb. 1969 through Sept. 1969. These scintigrams have been analyzed in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1) Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2) Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3) Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4) The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases (74-95% of all diseased livers). 5) The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6) Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape an margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  10. Ultrasonography and computed tomography in diffuse liver disease with cholestasis

    International Nuclear Information System (INIS)

    Partanen, K.; Pikkarainen, P.; Pasanen, P.; Alhava, E.; Soimakallio, S.; Kuopio Univ. Central Hospital; Kuopio Univ. Central Hospital

    1990-01-01

    Ultrasonography (US) and computed tomography (CT) were performed on respectively 67 and 42 (altogether 72) patients, for the assessment of intrahepatic cholestasis. The diagnostic ability to differentiate between malignant (17 patients) and benign (55 patients) liver disease was analyzed. Coarse echogenicity of the liver led to inconclusive results in differentiating between cirrhosis (2 out of 29 patients) and malignant infiltration (4 out of 15 patients) by US. Other benign liver diseases in 23 patients, including acute hepatitis, chronic active hepatitis, fatty liver, and liver congestion, were correctly interpreted as benign. CT correctly disclosed malignant liver disease in all cases. A false positive diagnosis of malignancy was encountered in 4 (out of 17) patients with decompensated hepatic cirrhosis because of non-homogeneous expansive areas on CT in 3 cases. The true cause was in 2 patients non-uniform fatty infiltration, and in one patient with acute hepatitis A, small hypodense lesions. Among cholestatic patients, decompensated cirrhosis and malignant liver infiltration could not always be differentiated on US or CT. (orig.)

  11. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    International Nuclear Information System (INIS)

    Oh, Wang Kyun; Kim, Sang Hyun

    2017-01-01

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver

  12. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Wang Kyun [Dept. of Radiology, Cheongju Medical Center, Cheongju (Korea, Republic of); Kim, Sang Hyun [Dept. of Radiological Science, Shinhan University, Uijeongbu (Korea, Republic of)

    2017-06-15

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

  13. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  14. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  15. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  16. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  17. Diagnosis of thromboembolic disease: combined ventilation perfusion lung scan and compression ultrasonography

    International Nuclear Information System (INIS)

    Dadparvar, S.; Woods, K.; Magno, R.M.; Sabatino, J. C.; Patil, S.; Dou, Y.

    2002-01-01

    The clinical management of pulmonary embolism and deep venous thrombosis of the legs are similar and require prolonged anticoagulation therapy. The standard diagnostic approach in patients suspected of pulmonary embolism is ventilation-perfusion (V/Q) lung scan and compression ultrasonography to detect deep venous thrombosis. This retrospective study analyzed the role of V Q lung scan and compression ultrasonography in detection of thromboembolic disease. One hundred-twenty consecutive patients (65 female, 55 male) age range 18-95 (mean age 60.7) suspected for pulmonary embolism underwent concomitant V/Q lung scan and compression ultrasonography of the lower extremities. The clinical and radiographic correlation was performed. Of patients with non-diagnostic (low or intermediate probability ) lung scans, 15.4 % (14/91) received anticoagulation therapy for pulmonary embolism. This patients had either high pre-clinical suspicion for PE or underwent pulmonary arterio gram. However, there was an additional 7 % (7/91) increase in the number of patients who received anticoagulation therapy based on the results of ultrasound with confidence interval (3 %-16 %). We conclude that V/Q lung scan is a more sensitive examination for thromboembolic disease, and has a high negative predictive value. Ultrasonography of lower extremities demonstrated higher specificity and positive value. Among patients with non-diagnostic lung scan, the detection rate of thromboembolic disease is improved with addition of ultrasound

  18. Ultrasonography of the liver anatomy, procedure, normal and abnormal findings in diseased states

    International Nuclear Information System (INIS)

    Fukuda, Morimichi

    1996-01-01

    Although the very first attempt to use ultrasound for diagnostic purpose in medicine may be traced back to the 1940's, the modern ultrasound imaging has only been started in 1963 by G. Kossoff, who developed the idea of grayscale ultrasonography together with the automatic waterbath scanner, Octoson, to examine pelvic and other abdominal organs. The signal processing, logarithmic compression of incoming backscattered echo signals, greatly Improved image quality and thus facilitated the use of ultrasound imaging in clinical diagnostic purposes. The bistable, black and white ultrasound equipment were used in the 60's, and even sophisticated B-mode contact scanners had been completely replaced by the real-time B-mode equipment and then the technique started to be used widely in medical imaging in clinical and radiology departments. These rather drastic changes took place since the introduction of the phased array technique introduced by Somer in 1967 and later the linear array method introduced by Bom in 1970. Other rare metabolic diseases have to be analyzed carefully for the differential diagnosis. In summary, ultrasonography is a useful measure to identify the presence of pathologic changes in the liver. The information obtained is mostly of morphological nature, though some additional findings could be obtained by careful analysis of the sonographic features. Examination is quick, non-invasive and findings are fairly reproducible and even very small lesions could be identified. Combined use of the ultrasound imaging with other modalities such as the radio isotope scanning, X ray, CT or MRI will be very helpful in identifying and characterising the lesions in the liver

  19. Ultrasonographic detection of hepatocellular carcinoma: correlation of preoperative ultrasonography and resected liver pathology

    International Nuclear Information System (INIS)

    Lim, J.H.; Kim, S.H.; Lee, W.J.; Choi, D.; Kim, S.H.; Lim, H.K.

    2006-01-01

    AIM: The aim of this study was to determine the sensitivity of ultrasonography for detecting hepatocellular carcinoma in patients who underwent surgical liver resection. MATERIALS AND METHODS: The preoperative ultrasonography reports of 103 patients who underwent hepatic resection surgery were retrospectively reviewed. The patients had chronic liver disease with good liver function and a relatively normal liver echotexture. The presence of a mass or masses in the resected part of the liver segments on preoperative ultrasonography was regarded as possible hepatocellular carcinoma, and these results were compared with the surgically resected hepatic lobes or segments. Accuracy for detection was assessed on a lesion-by-lesion basis, on a segment-by-segment basis, and on a patient basis. RESULTS: One hundred and fifty-seven hepatocellular carcinomas were found in 244 hepatic segments of 103 patients. One hundred and one of 157 hepatocellular carcinomas were detected using ultrasonography in 97 patients resulting in a sensitivity of 64%. In six patients, a solitary hepatocellular carcinoma was missed in each patient, a patient sensitivity being 94%. Using ultrasonography, 87 of 100 (87%) hepatocellular carcinomas larger than 2 cm in diameter, and 14 of 57 (25%) hepatocellular carcinomas 2 cm or smaller in diameter were revealed. On the basis of segment-by-segment analysis, the sensitivity was 78% (99 of 127 segments), specificity was 97% (114 of 117 segments), accuracy was 87% (213 of 244 segments), positive predictive value was 97% (99 of 102 segments), and negative predictive value was 80% (114 of 142 segments). CONCLUSION: In patients with chronic liver disease and good hepatic function, ultrasonography has a sensitivity of 94% in the identification of affected patients, but for individual lesions, the sensitivity is only 64%

  20. Three phase spiral liver Scanning

    International Nuclear Information System (INIS)

    Kanyanja, T.A.

    2006-01-01

    The ability to perform rapid back-to-back spiral acquisitions is an important recent technical advantage of spiral CT. this allows imaging of the upper abdomen (liver) during peak arterial enhancement (arterial phase) and during peak hepatic parenchymal enhancement (portal venous phase). Breatheld spiral CT has completely replaced dynamic incremental CT for evaluation of the liver. in selected patients with hyper vascular metastasis (hepatoma, neuroendocrine tumors, renal cell carcinoma, etc.) a biphasic examination is performed with one spiral acquisition obtained during the hepatic arterial phase and a second acquisition during the portal venous phase

  1. A prospective comparative assessment of the accuracy of the FibroScan in evaluating liver steatosis

    Science.gov (United States)

    Park, Eui Ju; Jang, Jae Young; Jeong, Soung Won; Lee, Sae Hwan; Kim, Sang Gyune; Cha, Sang-Woo; Kim, Young Seok; Cho, Young Deok; Kim, Hong Soo; Kim, Boo Sung; Jin, So Young; Park, Suyeon

    2017-01-01

    Background/aims Recent studies have demonstrated the utility of the FibroScan® device in diagnosing liver steatosis, but its usefulness has not been thoroughly appraised. We investigated the usefulness of the controlled attenuation parameter (CAP) in detecting and quantifying liver steatosis. Methods A prospective analysis was applied to 79 chronic liver disease patients who underwent a liver biopsy, a FibroScan investigation, ultrasonography, and hepatic steatosis index (HSI). The presence and degree of steatosis as measured by the FibroScan device, ultrasonography and HSI were compared with the results for the liver biopsy tissue. Results There was substantial concordance between the liver biopsy results and the CAP as evaluated by the kappa (κ) index test for detecting liver steatosis (κCAP = 0.77, Phepatic steatosis was 247 dB/m, which produced sensitivity and specificity values of 91.9% and 85.7%, respectively, as well as a positive predictive value of 85.0% and a negative predictive value of 92.3%. Conclusion The CAP produces results that are highly concordant with those of a liver biopsy in detecting steatosis. Therefore, the CAP is a noninvasive and reliable tool for evaluating liver steatosis, even in the early stages. PMID:28813448

  2. Clinical Significance of the Degree of Fatty Liver Diagnosed by Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Yong Kyun

    2008-01-01

    Fatty liver is one of the most commonly found disease by abdominal ultrasonography. The status of fatty liver is classified into mild, moderate and severe degrees. The study was conducted to investigate the clinical significance of fatty liver using ultrasonography. Test set consisted of 2,185 patients who visited D healthcare center in Daejeon to receive an abdominal ultrasonic test from January to December 2007. Out of the 2185 patients, 524 patients was diagnosed as fatty liver (290 male and 234 female patients). They were divided into three groups, group I for mild degree. II for moderate degree, and III for severe degree, depending on the echo of liver parenchyma, the sound attenuation, and the visibility of intrahepatic blood vessels and diaphragm. Then the correlation of obesity indices, liver function tests and metabolic syndrome was analyzed for males and females separately. As for the degree of fatty liver, 350 cases (66.8%) were classified as group I, 153 cases (29.2%) as group II, and 21 cases (4.1%) as group III. In addition, severe degree of fatty liver was more frequently found in males than in females. The mean ages of three groups for males were 46.1, 44.5, and 39.1, and those for females were 48.8, 50.2, 52.4, respectively. Males with lower mean ages have severely of fatty liver for both males and females. The results in this study show that the classification into three degrees of fatty liver in ultrasonography practice is helpful to treat and observe the progress of fatty liver. In addition, careful examination is required to measure the severity of fatty liver as well as detection of it. A standardized method to classify the degree of fatty liver is also needed for more objective measurement.

  3. Study on fatty liver diagnosed by abdominal ultrasonography and clinical laboratory findings

    International Nuclear Information System (INIS)

    Yang, Jeong Hwa

    2006-01-01

    The study obtained the following conclusions by making a comparative study on fatty liver diagnosed by abdominal ultrasonography and clinical laboratory findings. I surveyed the value of abdominal ultrasound in 400 patients without clinical symptoms at C Health Clinic Center, Seoul. Compare with blood pressure was high (systolic/diastolic) in 7.5%/4.5% on persons who were diagnosed fatty liver. At the time of the diagnosis, Total cholesterol level was increased in fatty liver patients, HDL-cholesterol level was high in fatty liver patients. And Trigryceride level was increased in fatty liver persons, LDL-cholesterol was high in fatty liver persons. SGOT level was increased in 5.5% on patients who were diagnosed fatty liver, 0% on persons who were normal and SGPT level was high in 29.5% on people who were diagnosed fatty liver, 0% on patients who were diagnosed normal

  4. Study on fatty liver diagnosed by abdominal ultrasonography and clinical laboratory findings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jeong Hwa [Cheju Halla College, Cheju (Korea, Republic of)

    2006-03-15

    The study obtained the following conclusions by making a comparative study on fatty liver diagnosed by abdominal ultrasonography and clinical laboratory findings. I surveyed the value of abdominal ultrasound in 400 patients without clinical symptoms at C Health Clinic Center, Seoul. Compare with blood pressure was high (systolic/diastolic) in 7.5%/4.5% on persons who were diagnosed fatty liver. At the time of the diagnosis, Total cholesterol level was increased in fatty liver patients, HDL-cholesterol level was high in fatty liver patients. And Trigryceride level was increased in fatty liver persons, LDL-cholesterol was high in fatty liver persons. SGOT level was increased in 5.5% on patients who were diagnosed fatty liver, 0% on persons who were normal and SGPT level was high in 29.5% on people who were diagnosed fatty liver, 0% on patients who were diagnosed normal.

  5. Diagnostic value of liver scintigraphy, computed tomography and ultrasonography of fatal hepatitis

    International Nuclear Information System (INIS)

    Komori, Hideshi; Hirasa, Masahiro; Ibuki, Yasuyoshi

    1983-01-01

    The purpose of this study was investigate the diagnostic value of liver scintigraphy, computed tomography (CT) and ultrasonography in acute hepatic failure, subacute hepatitis and acute hepatitis. By scintigraphy low uptake in the liver and high uptake in the spleen and bone marrow were observed in hepatic failure. However, uneven liver edge and heterogenous RI destribution were not corresponded to massive necrosis. In fulminant hepatitis, liver size and other findings were variable in patient by patient. But in subacute hepatitis, the findings were typical. The finding of left lobe swelling was observed in a half of patients with acute hepatic failure based on chronic hepatitis. Localized low density area by the CT was detected in most of the cases of subacute hepatitis, and acute hepatitis with submassive hepatic necrosis. But in fulminant hepatitis, that was rare. In these cases, irregular and strong lesion was also obsurved by ultrasonography. These findings by the CT and ultrasonography were corresponded to massive necrosis histrogically ultrasonography revealed narrowing of hepatic vein in fatal hepatitis. Localized low density area by the CT in subacute hepatitis was shown surrounding hepatic vein. We conclude that development of massine hepatic necrosis concern to secondary hepatic ischemia. (author)

  6. Evaluation of acute radiation optic neuropathy by B-scan ultrasonography

    International Nuclear Information System (INIS)

    Lovato, A.A.; Char, D.H.; Quivey, J.M.; Castro, J.R.

    1990-01-01

    We studied the accuracy of B-scan ultrasonography to diagnose radiation-induced optic neuropathy in 15 patients with uveal melanoma. Optic neuropathy was diagnosed by an observer masked as to clinical and photographic data. We analyzed planimetry area measurements of the retrobulbar nerve before and after irradiation. The retrobulbar area of the optic nerve shadow on B-scan was quantitated with a sonic digitizer. Increased optic nerve shadow area was confirmed in 13 of 15 patients who had radiation optic neuropathy (P less than .004). The correct diagnosis was confirmed when the results of ultrasound were compared to fundus photography and fluorescein angiography. In 13 patients there was acute radiation optic neuropathy. Two patients did not show an enlarged retrobulbar optic nerve, and the clinical appearance suggested early progression to optic atrophy. Ultrasonography documents the enlargement of the optic nerve caused by acute radiation changes

  7. Double-phase Tc-99m tetrofosmin parathyroid scan in hyperparathyroidism: comparison with ultrasonography

    International Nuclear Information System (INIS)

    Kim, In Soo; Kim, Sang Yoon; Zeon, Seok Kil; Won, Kyoung Sook

    2004-01-01

    This study was performed to evaluate the utility of double-phase Tc-99m Tetrofosmin(TF) parathyroid scan in the detection of pathologic lesions of primary hyperparathyroidism, and comparison with the ultrasonography(US). The double phase TF parathyroid scan of the anterior neck including upper mediastinum with 800 MBq TF were acquired at ten minutes (early phase) and at two hours (delayed phase) after radiopharmaceutical injection, in 24 consecutive patients under the clinical impression of primary hyperparathyroidism and hypercalcaemia. The images were evaluated for abnormal focal areas of increased tracer localization in the anterior neck and superior mediastinum in early phase, and visualization of parathyroid gland radioactivity after wash-out of the thyroid gland radioactivity in delayed phase. US of the anterior neck including upper mediastinum was performed by a diagnostic radiologist in 24 consecutive patients, within one week before or after the scan. The findings of double phase TF parathyroid scan and US were compared with the pathologic results. Ten of 24 patients were surgically explored and pathologic results showed eight adenomas and two hyperplasia. The double phase TF parathyroid scan showed positive findings in seven patients of eight adenomas and one patient of two hyperplasia patients. US image showed positive findings in six patients of eight adenomas and no positive findings of two hyperplasia. The sensitivity of the double phase TF scan for detection of the causes of the primary hyperparathyroidism was 80% and US was 60%. The double phase Tc-99m Tetrofosmin parathyroid scan showed higher sensitivity in detection of the pathologic lesions of primary hyperparathyroidism than ultrasonography

  8. Reappraisal of radionuclide liver scans for preoperative gastric cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Makoto; Yonahara, Yoshio; Yamashita, Shoji; Ando, Yutaka; Mohri, Makoto [National Second Hospital of Tokyo (Japan)

    1983-04-01

    Radionuclide liver scans were obtained in 89 preoperative patients with gastric cancer. Eight showed definite defects on liver scans. At laparotomy, 14 patients were found to have liver involvement secondary to gastric cancer. The sensitivity of liver scans to predict liver involvement is 57% (8/14), and the specificity is 100% (75/75). The patients with definite defects on liver scans had a lower rate of palliative resection of the primary tumors (2/8) than the patients with liver involvement and no scan abnormality (4/6). The patients with advanced lesions but without liver involvement had the highest probability of resecting the primary tumors (57/63 : 47 radical, and 10 palliative). Normal serum levels of liver chemistries did not preclude the presence of defects on liver scans. Additional three patients were found to have cirrhosis of the liver solely based on liver scans, which was confirmed at laparotomy. Radionuclide liver scans can predict liver involvement with very few false positives, and may discriminate patients unsuitable for laparotomy even with palliative intent.

  9. Cost-effectiveness analysis of ultrasonography screening for nonalcoholic fatty liver disease in metabolic syndrome patients

    Science.gov (United States)

    Phisalprapa, Pochamana; Supakankunti, Siripen; Charatcharoenwitthaya, Phunchai; Apisarnthanarak, Piyaporn; Charoensak, Aphinya; Washirasaksiri, Chaiwat; Srivanichakorn, Weerachai; Chaiyakunapruk, Nathorn

    2017-01-01

    Abstract Background: Nonalcoholic fatty liver disease (NAFLD) can be diagnosed early by noninvasive ultrasonography; however, the cost-effectiveness of ultrasonography screening with intensive weight reduction program in metabolic syndrome patients is not clear. This study aims to estimate economic and clinical outcomes of ultrasonography in Thailand. Methods: Cost-effectiveness analysis used decision tree and Markov models to estimate lifetime costs and health benefits from societal perspective, based on a cohort of 509 metabolic syndrome patients in Thailand. Data were obtained from published literatures and Thai database. Results were reported as incremental cost-effectiveness ratios (ICERs) in 2014 US dollars (USD) per quality-adjusted life year (QALY) gained with discount rate of 3%. Sensitivity analyses were performed to assess the influence of parameter uncertainty on the results. Results: The ICER of ultrasonography screening of 50-year-old metabolic syndrome patients with intensive weight reduction program was 958 USD/QALY gained when compared with no screening. The probability of being cost-effective was 67% using willingness-to-pay threshold in Thailand (4848 USD/QALY gained). Screening before 45 years was cost saving while screening at 45 to 64 years was cost-effective. Conclusions: For patients with metabolic syndromes, ultrasonography screening for NAFLD with intensive weight reduction program is a cost-effective program in Thailand. Study can be used as part of evidence-informed decision making. Translational Impacts: Findings could contribute to changes of NAFLD diagnosis practice in settings where economic evidence is used as part of decision-making process. Furthermore, study design, model structure, and input parameters could also be used for future research addressing similar questions. PMID:28445256

  10. GLCM algorithm image analysis of nonalcoholic fatty liver and focal fat sparing zone in the ultrasonography

    International Nuclear Information System (INIS)

    Cho, Jin Young; Ye, Soo Young

    2017-01-01

    There is a need for aggressive diagnosis and treatment in middle-aged and high-risk individuals who are more likely to progress from nonalcoholic fatty liver to hepatitis. In this study, nonalcoholic fatty liver was divided into severe, moderate, and severe, and classified by quantitative method using computer analysis of GLCM algorithm. The purpose of this study was to evaluate the characteristics of ultrasound images in the local fat avoidance region. Normal, mild, moderate, severe fatty liver, and focal fat sparing area, 80 cases, respectively. Among the parameters of the GLCM algorithm, the values of the Autocorrelation, Square of the deviation, Sum of averages and Sum of variances with high recognition rate of the liver ultrasound image were calculated. The average recognition rate of the GLCM algorithm was 97.5%. The result of local fat avoidance image analysis showed the most similar value to the normal parenchyma. Ultrasonography can be easily accessed by primary screening, but there may be differences in the accuracy of the test method or the correspondence of results depending on proficiency. GLCM algorithm was applied to quantitatively classify the degree of fatty liver. Local fat avoidance region was similar to normal parenchyma, so it could be predicted to be homogeneous liver parenchyma without fat deposition. We believe that GLCM computer image analysis will provide important information for differentiating not only fatty liver but also other lesions

  11. GLCM algorithm image analysis of nonalcoholic fatty liver and focal fat sparing zone in the ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jin Young [Dept. of Radiological Science, Graduate School of Catholic University of Pusan, Busan (Korea, Republic of); Ye, Soo Young [Dept. of Radiological Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2017-06-15

    There is a need for aggressive diagnosis and treatment in middle-aged and high-risk individuals who are more likely to progress from nonalcoholic fatty liver to hepatitis. In this study, nonalcoholic fatty liver was divided into severe, moderate, and severe, and classified by quantitative method using computer analysis of GLCM algorithm. The purpose of this study was to evaluate the characteristics of ultrasound images in the local fat avoidance region. Normal, mild, moderate, severe fatty liver, and focal fat sparing area, 80 cases, respectively. Among the parameters of the GLCM algorithm, the values of the Autocorrelation, Square of the deviation, Sum of averages and Sum of variances with high recognition rate of the liver ultrasound image were calculated. The average recognition rate of the GLCM algorithm was 97.5%. The result of local fat avoidance image analysis showed the most similar value to the normal parenchyma. Ultrasonography can be easily accessed by primary screening, but there may be differences in the accuracy of the test method or the correspondence of results depending on proficiency. GLCM algorithm was applied to quantitatively classify the degree of fatty liver. Local fat avoidance region was similar to normal parenchyma, so it could be predicted to be homogeneous liver parenchyma without fat deposition. We believe that GLCM computer image analysis will provide important information for differentiating not only fatty liver but also other lesions.

  12. Enhancing the early differential diagnosis of plateau iris and pupillary block using a-scan ultrasonography.

    Directory of Open Access Journals (Sweden)

    Yu-Yen Chen

    Full Text Available To distinguish the frequently misdiagnosed plateau iris eyes from pupillary block group and normal group, we compared the ocular biometrical parameters of them by A-scan ultrasongraphy.In total, we retrospectively reviewed general characteristics and ocular findings including ocular biometric measurements of 71 normal, 39 plateau iris, and 83 pupillary block eyes.The normal controls, plateau iris group and pupillary block group were significantly different in age, but not in gender. The anterior chamber depth tended to decrease and the lens thickness tended to increase from normal to plateau iris to pupillary block eyes. Compared to those of plateau iris group, the pupillary block group had significantly shallower anterior chamber depth (2.90mm vs. 2.33mm; p<0.001, thicker lens (4.77mm vs. 5.11mm; p<0.001, shorter axial length (23.16mm vs. 22.63mm; p<0.001, smaller relative lens position (2.28 vs. 2.16; p<0.001 and larger lens/axial length factor (2.06 vs. 2.26; p<0.001. However, when comparing plateau iris and normal eyes, only axial length and lens/axial length factor were significantly different (23.16 vs. 23.54; p<0.05 and 2.06 vs. 1.96; p<0.05.Measured by A-scan ultrasonography, the ocular biometrics of plateau iris were significantly different from those of pupillary block eyes. However, our A-scan ultrasongraphy generally found no significant biometric differences between plateau iris and normal eyes. These findings suggest that while A-scan ultrasonography might be used as a practical tool for differentiating plateau iris and papillary block eyes, a more meticulous gonioscopy and other assessments may be necessary to distinguish plateau iris from normal eyes.

  13. A comparison between intrastomal 3D ultrasonography, CT scanning and findings at surgery in patients with stomal complaints.

    Science.gov (United States)

    Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K

    2014-10-01

    Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.

  14. Finding of biliary fascioliasis by endoscopic ultrasonography in a patient with eosinophilic liver abscess.

    Science.gov (United States)

    Behzad, Catherine; Lahmi, Farhad; Iranshahi, Majid; Mohammad Alizadeh, Amir Houshang

    2014-09-01

    Fascioliasis is an endemic zoonotic disease in Iran. It occurs mainly in sheep-rearing areas of temperate climates, but sporadic cases have been reported from many other parts of the world. The usual definitive host is the sheep. Humans are accidental hosts in the life cycle of Fasciola. Typical symptoms may be associated with fascioliasis, but in some cases diagnosis and treatment may be preceded by a long period of abdominal pain and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 6 months, with imaging suggesting liver abscess and normal biliary ducts. The patient had no eosinophilia with negative stool examinations, so she was initially treated with antibiotics for liver abscess. Her clinical condition as well as follow-up imagings showed appropriate response after antibiotic therapy. Finally, endoscopic ultrasonography revealed Fasciola hepatica, which was then extracted with endoscopic retrograde cholangiopancreatography.

  15. Endoscopic ultrasonography and computed tomography scanning for preoperative staging of colonic cancer

    DEFF Research Database (Denmark)

    Malmstrøm, M L; Gögenur, I; Riis, L B

    2017-01-01

    PURPOSE: With an increasing demand for more accurate preoperative staging methods for colon cancer, we aimed to compare preoperative tumour (T)- and nodal (N)-stage in patients with left-sided colon cancer by endoscopic ultrasonography (EUS) and computed tomography (CT) with post......-operative histology as gold standard. METHODS: A total of 44 patients were prospectively recruited at Herlev and Roskilde University Hospitals during November 2014-January 2016. Thirty-five patients were included in the final analysis and underwent EUS, CT and surgery within 2 weeks. Diagnostic values were evaluated...... difficult to evaluate due to small patient numbers. EUS could be considered as a supplement to CT scans in selecting patients for neoadjuvant therapies, or local transmural treatment, in the future. TRIAL REGISTRATION: NCT02324023....

  16. Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography

    Directory of Open Access Journals (Sweden)

    Nikoo Hamzeh

    2015-12-01

    Full Text Available AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT in comparison with A-scan ultrasonography (A-scan US. METHODS: There were 218 adult subjects (218 eyes aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System III (LOCS III. Lens thickness was measured by AS-OCT (Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA. The highest quality image was selected for each eye and lens thickness was calculated using ImageJ software. Lens thickness was also measured by A-scan US. RESULTS: Interclass correlations showed a value of 99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US (4.861±0.404 vs 4.866±0.351 mm, P=0.74. Lens thickness values obtained from the two instruments were highly correlated overall (Pearson correlation coefficient=0.81, P<0.001, and in all LOCS III specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from -0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens (β=-0.29, P<0.001 CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.

  17. Hyperdynamic circulatory changes in liver cirrhosis: Comparative evaluation by doppler ultrasonography with normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Im, Dae Wook; Baik, Soon Koo; Suh, Jung In; Kim, Jae Woo; Park, Yong Soon; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok [Yonsei University, Wonju College of Medicine, Wonju (Korea, Republic of)

    2001-12-15

    To evaluate the cardiovascular and splanchnic hemodynamic changes in patients with liver cirrhosis and to compare with those of the normal controls using doppler ultrasonography. A total of 129 patients including 23 of Child-Pugh class A, 24 of class A, 24 of class B, 30 of class C, and 52 of the control group were included. Cardiac output (CO), systemic vascular resistance index (SVRI), and blood flow and pulsatility index (PI) of the superior mesenteric artery (SMA) were evaluated and compared among each groups. CO and SMA blood flow in the cirrhotic group were significantly higher than those in the control group, and the increase in CO and SMA blood flow showed a statistically significant correlation with the degree of liver dysfunction (p<0.01). SVRI and SMA PI reflecting vascular resistance in the cirrhotic group were significantly lower than those in the control group, and the decrease in SVRI and SMA PI also showed a statistically significant correlation with the degree of liver dysfunction (p<0.01). SMA blood flow showed a statistically significant inverse relationship with SMA PI (R{sup 2}=0.230). Hyperdynamic circulatory changes such as increases in CO and splanchnic blood flow were present in patients with liver cirrhosis. These changes may contribute to the development and maintenance of the portal hypertension due to an increase in portal blood flow an increase in portal blood flow.

  18. Hyperdynamic circulatory changes in liver cirrhosis: Comparative evaluation by doppler ultrasonography with normal subjects

    International Nuclear Information System (INIS)

    Im, Dae Wook; Baik, Soon Koo; Suh, Jung In; Kim, Jae Woo; Park, Yong Soon; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok

    2001-01-01

    To evaluate the cardiovascular and splanchnic hemodynamic changes in patients with liver cirrhosis and to compare with those of the normal controls using doppler ultrasonography. A total of 129 patients including 23 of Child-Pugh class A, 24 of class A, 24 of class B, 30 of class C, and 52 of the control group were included. Cardiac output (CO), systemic vascular resistance index (SVRI), and blood flow and pulsatility index (PI) of the superior mesenteric artery (SMA) were evaluated and compared among each groups. CO and SMA blood flow in the cirrhotic group were significantly higher than those in the control group, and the increase in CO and SMA blood flow showed a statistically significant correlation with the degree of liver dysfunction (p 2 =0.230). Hyperdynamic circulatory changes such as increases in CO and splanchnic blood flow were present in patients with liver cirrhosis. These changes may contribute to the development and maintenance of the portal hypertension due to an increase in portal blood flow an increase in portal blood flow.

  19. Evaluation of lateral margin of left lobe of the liver on CT scan : focus on perisplenic extension

    International Nuclear Information System (INIS)

    Seo, Chang Hye; Cha, Seong Sook; Lee, Byung Jin; Choi, Jae Young; Choi, Seok Jin; Eun, Choong Ki

    1996-01-01

    The perisplenic extension of the left lobe of the liver can be misinterpreted as a splenic or perisplenic lesion on ultrasonography(US) and computed tomography(CT). The purpose of our study is to classify the lateral margin of the left lobe of the liver into three types and to evaluate the incidence and the relationship between each type and abnormal liver on CT scan. A total of 515 abdominal CT scans from patients over 15 years old were retrospectively evaluated. Liver contours were divided into three types on the basis of degree of the left lateral extension of the left lobe of the liver. Type A was defined as the lateral extension of the left lobe of liver to the medial portion of the stomach, type C as the perisplenic portion, and type B as between the two types. Each type was further divided into normal and abnormal liver groups based on clinical, CT, surgical and patholigic findings and evaluated on its ratio of normal and abnormal liver, intrahepatic diseases associated with an abnormal liver and statistical significance between a normal and abnormal liver. The incidence of the three types of liver among the 515 patients was 360(69.9%), 121(23.5%) and 34(6.6%) patients in type A, B and C, respectively. Type C showed normal liver in six patients, which was 2.7% of all normal livers(221/515) and abnormal liver in 28 patients, which was 9.5% of all abnormal livers(294/515). Type A showed normal liver in 49.7%, abnormal liver in 50.3% and there was not statistically significant difference between normal and abnormal liver(p>0.05). Type B showed normal liver in 29.8% and abnormal liver in 70.2%;type C showed normal liver in 17.6%, abnormal liver in 82.4% and there was a statistically significant difference between normal and abnormal liver(P<0.001). The space occupying lesion(SOL) was most common(52.6%) in all the abnormal livers and hepatoma was the most common disease in the SOL(47.2%). In the abnormal type C liver, SOL(58%) and diffuse hepatopathy(32.8%) were

  20. Accuracy of FibroScan for diagnosing liver fibrosis

    Directory of Open Access Journals (Sweden)

    Jian ZHANG

    2011-11-01

    Full Text Available Objective To evaluate the accuracy of transient elastometry(FibroScan for the detection of liver fibrosis.Methods A total of 323 patients diagnosed with chronic liver disease based on pathological examination in the 302 Hospital of the People’s Liberation Army from April to December of 2009 were involved in the current study.Among them,141 patients were subjected to liver biopsy.Their liver function,coagulant index,B-ultrasound and blood cell count were examined clinically.Four examinations related to liver fibrosis were done on some of the patients.Meanwhile,FibroScan was used for liver stiffness measurement(LSM of every patient.The correlation between liver stiffness and the serologic index and liver fibrosis degree was analyzed.The Receive Operating Characteristic(ROC curve was adopted to analyze the accuracy of FibroScan for diagnosing liver fibrosis.Results Each serologic index was significantly correlated with liver stiffness(P < 0.001,and liver stiffness was closely related to the stage of liver fibrosis(r=0.74,P < 0.001.The statistical results of the 141 patients who underwent pathologic examination show that the areas under the ROC curve were 0.97(0.94,1.00 for patients with portal fibrosis(F1,0.96(0.93,0.99 for patients with significant fibrosis(F2,0.99(0.98,1.00 for patients with severe fibrosis(F3,and 0.97(0.94,0.99 for patients with cirrhosis(F4.The cutoff values were 4.4KPa,6.8KPa,9.7KPa,and 10.0KPa,respectively.Conclusion FibroScan is valuable for the diagnosis of liver fibrosis.It can be used as the basis for follow-up and management of patients with chronic liver diseases.

  1. Assessment of liver volume with spiral computerized tomography scanning: predicting liver volume by age and height

    OpenAIRE

    Madhu Sharma; Abhishek Singh; Shewtank Goel; Setu Satani; Kavita Mudgil

    2016-01-01

    Background: Estimation of liver size has critical clinical implication. Precise knowledge of liver dimensions and volume is prerequisite for clinical assessment of liver disorders. Liver span as measured by palpation and USG is prone to inter-observer variability and poor repeatability. The aim was to assess the normal liver volume of healthy adults using spiral computed tomography scans and to observe its relationship with various body indices. Methods: In this prospective study, all the...

  2. ROC Analysis of Diagnostic Performance in Liver Scan

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Moon, Dyuk Hyuk; Koh, Chang Soon; Matumoto, Toru; Tateno, Yukio

    1988-01-01

    To evaluate diagnostic accuracy of liver scintigraphy we analysed liver scans of 143 normal and 258 patients with various liver diseases. Three ROC curves for SOL, liver cirrhosis and diffuse liver disease were fitted using rating methods and areas under the ROC curves and their standard errors were calculated by the trapezoidal rule and the variance of the Wilcoxon statistic suggested by McNeil. We compared these results with that of National Institute of Radiological Science in Japan. 1) The sensitivity of liver scintigraphy was 74.2% in SOL, 71.8% in liver cirrhosis and 34.8% in diffuse liver disease. The specificity was 96.0% in SOL, 94.2% in liver cirrhosis and 87.6% in diffuse liver disease. 2) ROC curves of SOL and liver cirrhosis approached the upper left-hand corner closer than that of diffuse liver disease. Area (± standard error) under the ROC curve was 0.868±0.024 in SOL and 0.867±0.028 in liver cirrhosis. These were significantly higher than 0.658±0.043 in diffuse liver disease. 3) There was no interobserver difference in terms of ROC curves. But low sensitivity and high specificity of authors' SOL diagnosis suggested we used more strict decision threshold.

  3. Ultrasonography as a non-invasive tool for detection of nonalcoholic fatty liver disease in overweight/obese Egyptian children

    International Nuclear Information System (INIS)

    El-Koofy, Nehal; El-Karaksy, Hanaa; El-Akel, Wafaa; Helmy, Heba; Anwar, Ghada; El-Sayed, Rokaya; El-Hennawy, Ahmad

    2012-01-01

    Introduction: Liver biopsy, although a gold standard in diagnosis of nonalcoholic fatty liver disease (NAFLD), is an invasive and expensive tool. Aim: To assess the diagnostic accuracy of abdominal ultrasound in detecting NAFLD among a group of overweight/obese children having one or more liver abnormality (clinical hepatomegaly, raised ALT or echogenic liver parenchyma by ultrasound). Methods: Seventy-eight overweight/obese children were referred to the Pediatric Hepatology Unit, Cairo University Pediatric Hospital, Egypt, for assessment for hepatic abnormalities. Out of the 78 children, 34 had one or more abnormality in the form of clinical hepatomegaly, raised alanine aminotransferase (ALT) and/or echogenic liver parenchyma by ultrasound. All 34 cases underwent liver biopsy for evaluation for NAFLD. Results: Histological NAFLD was detected in 15 cases; 8 simple steatosis and 7 nonalcoholic steatohepatitis (NASH). Sonographic evaluation of hepatic parenchymal echogenicity revealed: 11 with grade 1 echogenicity, 12 with grade 2 and 9 with grade 3 while only 2 had normal liver echopattern. Ultrasonography was 100% sensitive and 100% specific in detecting histological NAFLD, while the positive predictive value (PPV) was 47% and negative predictive value (NPV) was 11%. After consolidating the included children into 2 groups: the first including normal and grade 1 echogenicity and the second including grades 2 and 3, the sensitivity of ultrasonography in detecting histological NAFLD was still 100%, while negative predictive value increased to 100% with an accuracy of 82%. Conclusion: We conclude that ultrasonography is an important non invasive tool in assessment for NAFLD. Normal or grade 1 hepatic echogenicity can soundly exclude histological NAFLD and obviates the need for liver biopsy.

  4. Ultrasonography as a non-invasive tool for detection of nonalcoholic fatty liver disease in overweight/obese Egyptian children

    Energy Technology Data Exchange (ETDEWEB)

    El-Koofy, Nehal [Department of Pediatrics, Cairo University (Egypt); El-Karaksy, Hanaa, E-mail: hanaakaraksy@yahoo.com [Department of Pediatrics, Cairo University (Egypt); El-Akel, Wafaa [Tropical Medicine, Cairo University (Egypt); Helmy, Heba; Anwar, Ghada; El-Sayed, Rokaya [Department of Pediatrics, Cairo University (Egypt); El-Hennawy, Ahmad [Pathology, Faculty of Medicine, Cairo University (Egypt)

    2012-11-15

    Introduction: Liver biopsy, although a gold standard in diagnosis of nonalcoholic fatty liver disease (NAFLD), is an invasive and expensive tool. Aim: To assess the diagnostic accuracy of abdominal ultrasound in detecting NAFLD among a group of overweight/obese children having one or more liver abnormality (clinical hepatomegaly, raised ALT or echogenic liver parenchyma by ultrasound). Methods: Seventy-eight overweight/obese children were referred to the Pediatric Hepatology Unit, Cairo University Pediatric Hospital, Egypt, for assessment for hepatic abnormalities. Out of the 78 children, 34 had one or more abnormality in the form of clinical hepatomegaly, raised alanine aminotransferase (ALT) and/or echogenic liver parenchyma by ultrasound. All 34 cases underwent liver biopsy for evaluation for NAFLD. Results: Histological NAFLD was detected in 15 cases; 8 simple steatosis and 7 nonalcoholic steatohepatitis (NASH). Sonographic evaluation of hepatic parenchymal echogenicity revealed: 11 with grade 1 echogenicity, 12 with grade 2 and 9 with grade 3 while only 2 had normal liver echopattern. Ultrasonography was 100% sensitive and 100% specific in detecting histological NAFLD, while the positive predictive value (PPV) was 47% and negative predictive value (NPV) was 11%. After consolidating the included children into 2 groups: the first including normal and grade 1 echogenicity and the second including grades 2 and 3, the sensitivity of ultrasonography in detecting histological NAFLD was still 100%, while negative predictive value increased to 100% with an accuracy of 82%. Conclusion: We conclude that ultrasonography is an important non invasive tool in assessment for NAFLD. Normal or grade 1 hepatic echogenicity can soundly exclude histological NAFLD and obviates the need for liver biopsy.

  5. Comparison of supine, upright, and prone positions for liver scans

    International Nuclear Information System (INIS)

    Harolds, J.A.; Brill, A.B.; Patton, J.A.; Touya, J.J.

    1983-01-01

    We compared liver scan interpretations based on anterior images obtained in the upright, prone, and supine positions. Receiver-operating-characteristic curves were generated for three well trained observers. Results showed that reading the three different views together was more accurate than the reading of any individual image. Furthermore, interpretations based on either the prone or upright view were superior to those using the supine view alone. The prone and upright views should be used more often in liver scanning

  6. Liver scanning with sup(99m)Tc-phytate

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, A; Isobe, Y; Kobayashi, T; (Keio Univ., Tokyo (Japan). School of Medicine); Kinoshita, Fumio; Shibata, Masayoshi

    1975-03-01

    /sup 198/Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with /sup 198/Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with /sup 198/Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of /sup 198/Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease.

  7. Liver scanning with sup(99m)Tc-phytate

    International Nuclear Information System (INIS)

    Kubo, Atsushi; Isobe, Yoshinori; Kobayashi, Takeshi; Kinoshita, Fumio; Shibata, Masayoshi.

    1975-01-01

    198 Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with 198 Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with 198 Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of 198 Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease. (auth.)

  8. Anatomy of the portal and hepatic veins of the dog: a basis for systematic evaluation of the liver by ultrasonography

    International Nuclear Information System (INIS)

    Carlisle, C.H.; Wu, J.X.; Heath, T.J.

    1995-01-01

    The objective of this study was to define, in detail, the anatomy of the portal and hepatic veins in the dog in order to establish a procedure for the systematic evaluation of the liver by ultrasonography. Anatomical details were obtained from the formalin fixed livers of ten dogs. The hepatic and portal veins were removed intact from these livers so that a detailed pattern of distribution could be established and the numbers of branches could be counted. Silastic casts were also made of the hepatic and portal veins of two livers, one in situ and one in which it had been removed. The former was to enable the relationship of the portal to the hepatic veins to be established as closely as possible within the animal and the other to provide a model of the distribution of each venous system within the liver. Contrast medium was infused into two other livers and radiographs taken to establish the relationship of each branch to each lobe. It was found that there was a consistent pattern of venous branching to each lobe of the liver in the dog with little variation between individual specimens. All liver lobes contained definite venous branches so that the left lateral and medial, quadrate, right medial and lateral, caudate and papillary veins could be distinguished in each venous system. We believe that an appreciation of this venous distribution will aid in the systematic evaluation of the liver during ultrasonography by enabling identification of each liver lobe. It should be of value for differentiating portal from hepatic veins and veins from dilated bile ducts

  9. Difficulties in the interpretation of focal changes on liver scans

    Energy Technology Data Exchange (ETDEWEB)

    Derimanov, S.G. (Oblastnoj Onkologicheskij Dispanser, Veliko-Tyrnovo (Bulgaria))

    1983-01-01

    A series of cases are presented in which erroneous conclusions were arrived at by liver scans. The analysis of these errors has shown that they are determined by the similarity of a scanographic picture of focal changes in various diseases of the liver (cancer, cirrhosis, echinococcus, etc.) and the adjacent organs (bronchogenic cyst, renal tumor, etc.). In this connection all attempts to determine the etiology of a pathological process by liver scans without correlation with the results of multidimensional examination frequently result in errors.

  10. Radiofrequency ablation of liver cancer: early evaluation of therapeutic response with contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Choi, Dong Gil; Lim, Hyo K.; Lee, Won Jae; Kim, Seung Hoon; Kim, Min Ju; Kim, Seung Kwon; Jang, Kyung Mi; Lee, Ji Yeon; Lim, Jae Hoon

    2004-01-01

    The early assessment of the therapeutic response after percutaneous radiofrequency (RF) ablation is important, in order to correctly decide whether further treatment is necessary. The residual unablated tumor is usually depicted on contrast-enhanced multiphase helical computed tomography (CT) as a focal enhancing structure during the arterial and portal venous phases. Contrast-enhanced color Doppler and power Doppler ultrasonography (US) have also been used to detect residual tumors. Contrast-enhanced gray-scale US, using a harmonic technology which has recently been introduced, allows for the detection of residual tumors after ablation, without any of the blooming or motion artifacts usually seen on contrast-enhanced color or power Doppler US. Based on our experience and reports in the literature, we consider that contrast-enhanced gray-scale harmonic US constitutes a reliable alternative to contrast-enhanced multiphase CT for the early evaluation of the therapeutic response to RF ablation for liver cancer. This technique was also useful in targeting any residual unablated tumors encountered during additional ablation

  11. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    International Nuclear Information System (INIS)

    Pescatori, Lorenzo Carlo; Sconfienza, Luca Maria; Mauri, Giovanni

    2016-01-01

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic

  12. Comparison of radiography and ultrasonography in the detection of lung and liver cysts in cattle and buffaloes

    Directory of Open Access Journals (Sweden)

    Ashwani Kumar

    2016-10-01

    Full Text Available Aim: Echinococcosis is the major cause of lung and liver cysts in ruminants. This study compared usefulness of radiography and ultrasonography (USG in the detection of lung and/or liver cysts in sick bovine animals. The study also worked out cooccurrence of lung and liver cysts, and whether these cysts were primary cause of sickness or not. Materials and Methods: This study was conducted on 45 sick bovine (37 buffaloes and 8 cattle suffering from lung and liver cysts. A complete history of illness and clinical examination was carried out. Lateral radiographs of chest and reticular region were taken. In radiographically positive or suspected cases of cysts, USG of the lung and liver region was done. Depending on the location of cyst and clinical manifestations of the animal, the cysts were categorized as primary or secondary causes of sickness. Results: Using either imaging technique, it was observed that 46.7% of the animals had both lung and liver cysts, whereas 33.3% had only lung and 20% had only liver cyst. Cysts were identified as primary cause of sickness in 31.1% animals only. For diagnosing lung cysts, radiography (71.1% and USG (62.2% had similar diagnostic utility. However, for detecting liver cysts, USG was the only imaging tool. Conclusion: The lung and liver cysts, depending on their number and size may be a primary cause of sickness in bovine. Radiography and USG are recommended, in combination, as screening tools to rule out echinococcosis.

  13. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  14. Ultrasonography of the liver, spleen, and urinary tract of the cheetah (Acinonyx jubatus).

    Science.gov (United States)

    Carstens, Ann; Kirberger, Robert M; Spotswood, Tim; Wagner, Wencke M; Grimbeek, Richard J

    2006-01-01

    Diseases of the abdomen of the cheetah (Acinonyx jubatus) include those affecting the liver, spleen, and urinary tract. The most common diseases of captive-bred cheetah are gastritis, gastric ulceration, glomerulosclerosis, and hepatic veno-occlusive disease, and are the most frequent causes of mortality in these animals. The purpose of this study was to describe the ultrasonographic anatomy of the normal liver, spleen, kidney, and urinary bladder of the anesthetized captive-bred cheetah. Twenty-one cheetahs were examined. Eight of the 21 animals had subclinical evidence of either gastritis or chronic renal disease. The ultrasonographic appearances of the liver, gall bladder, common bile duct, and spleen were evaluated and various measurements made. Statistical analyses of the measurements were performed on all the healthy and subclinically ill animals taking sex, age, mass, and anesthetic protocol into account. There were no significant differences in any parameters between the healthy and subclinically ill animals (P > 0.25) and data were combined for statistical analyses. The mean mass was 41.1kg ( +/- 8.8) and the mean age was 5.0 years (+/- 2.2). The mean thickness of the liver medial to the gall bladder was 67.0 mm (+/- 14.8) and the liver was within the left costal arch in 75% of animals, extended caudal to the right costal arch in 50% of animals for an average of 30 mm, and extended caudal to the sternum in 63% of animals for an average of 32.5 mm. The maximum mean hepatic vein diameter at the entrance to the caudal vena cava was 8.6 +/- 2.8 mm; the mean diameters of the portal vein at the hilus and that of the caudal vena cava as it entered the liver were 7.5 +/- 1.6 and 9.9 +/- 4.1 mm, respectively. The mean diameter of the caudal vena cava was significantly affected by the type of anesthetic used (P < 0.10). The mass of the animals was significant in explaining the variance in maximum portal vein diameters (P < 0.10). The mean maximum velocity of the

  15. Liver scanning in short interval autopsy material of cancer patients

    International Nuclear Information System (INIS)

    Appelqvist, P.; Salmo, M.; Kostiainen, S.

    1980-01-01

    The accuracy of liverscanning alkaline phosphatase and 5'-nucleotidase in the detection of the hepatic metastases was studied in short interval autopsy material of 243 cancer patients. The highest percentage of correct diagnosis was by 5'-nucleotidase, alkaline phosphatase was the second, and scanning third. The overall accuracy of liver scan was 68 per cent. It was the better the shorter the time interval between scanning and autopsy. The higher percentage of incorrect diagnoses of the scan was related to a larger number of false positives, the causes of which were to be verified only in half of the cases. (orig.) [de

  16. Doppler ultrasonography combined with transient elastography improves the non-invasive assessment of fibrosis in patients with chronic liver diseases.

    Science.gov (United States)

    Alempijevic, Tamara; Zec, Simon; Nikolic, Vladimir; Veljkovic, Aleksandar; Stojanovic, Zoran; Matovic, Vera; Milosavljevic, Tomica

    2017-01-31

    Accurate clinical assessment of liver fibrosis is essential and the aim of our study was to compare and combine hemodynamic Doppler ultrasonography, liver stiffness by transient elastography, and non-invasive serum biomarkers with the degree of fibrosis confirmed by liver biopsy, and thereby to determine the value of combining non-invasive method in the prediction significant liver fibrosis. We included 102 patients with chronic liver disease of various etiology. Each patient was evaluated using Doppler ultrasonography measurements of the velocity and flow pattern at portal trunk, hepatic and splenic artery, serum fibrosis biomarkers, and transient elastography. These parameters were then input into a multilayer perceptron artificial neural network with two hidden layers, and used to create models for predicting significant fibrosis. According to METAVIR score, clinically significant fibrosis (≥F2) was detected in 57.8% of patients. A model based only on Doppler parameters (hepatic artery diameter, hepatic artery systolic and diastolic velocity, splenic artery systolic velocity and splenic artery Resistance Index), predicted significant liver fibrosis with a sensitivity and specificity of75.0% and 60.0%. The addition of unrelated non-invasive tests improved the diagnostic accuracy of Doppler examination. The best model for prediction of significant fibrosis was obtained by combining Doppler parameters, non-invasive markers (APRI, ASPRI, and FIB-4) and transient elastography, with a sensitivity and specificity of 88.9% and 100%. Doppler parameters alone predict the presence of ≥F2 fibrosis with fair accuracy. Better prediction rates are achieved by combining Doppler variables with non-invasive markers and liver stiffness by transient elastography.

  17. Efficacy for preoperative screening of liver metastasis using computed tomography and ultrasonography in patients with colon cancer

    International Nuclear Information System (INIS)

    Kotanagi, Hitoshi; Sato, Emi; Murakoshi, Satoshi

    2000-01-01

    To establish an effective examination system for preoperative evaluation of liver metastasis by colon cancer, we analyzed the sensitivity, cost, and efficacy of computed tomography (CT) and ultrasonography (US) in 354 patients (including 63 patients with liver metastasis). The presence or absence of liver metastasis was ultimately diagnosed 5 years after the operation. The sensitivity, specificity, and accuracy for detecting liver metastasis were 65%, 94%, and 89%, respectively for CT, 57%, 97%, and 91% for US, and 65%, 93%, and 88% for CT plus US, and there were no significant differences among them. Neither CT nor US could fully detect intrahepatic cancer spread. The cost of detection of one patient with liver metastasis was 6,298 points for plain CT, 20,169 points for enhanced CT, and 5,773 points for US. It was concluded that CT plus US should not be employed for preoperative assessment of liver metastasis, because the detection rate of the two modalities is not significantly different, and these modalities do not compensate for each other's defects. From the standpoint of the cost-benefit relationship, US should be selected for preoperative evaluation of liver metastasis. (author)

  18. Value of hepatobiliary scanning in complex liver trauma

    International Nuclear Information System (INIS)

    Gartman, D.M.; Zeman, R.K.; Cahow, C.E.; Baker, C.C.

    1985-01-01

    To evaluate the use of biliary scintigraphy with /sup 99m/Tc-dimethyl analogs (HIDA) in traumatic liver injuries, a group of 26 patients with penetrating and blunt liver injuries were studied. The results indicate that HIDA scanning is an effective noninvasive method of evaluating the hepatobiliary tree in the post-traumatic setting. The HIDA scan is a sensitive tool for studying the hepatic parenchyma and the presence or absence of bile leaks. Its evaluation of the extrahepatic biliary ductal system is not specific and should be assessed with further studies. Gallbladder nonvisualization by HIDA scans in this setting cannot be presumed to be secondary to acute cholecystitis and should be interpreted with extreme caution

  19. CONSUMER PREFERENCES FOR SCANNING MODALITY TO DIAGNOSE FOCAL LIVER LESIONS.

    Science.gov (United States)

    Whitty, Jennifer; Filby, Alexandra; Smith, Adam B; Carr, Louise M

    2015-01-01

    Differences in the process of using liver imaging technologies might be important to patients. This study aimed to investigate preferences for scanning modalities used in diagnosing focal liver lesions. A discrete choice experiment was administered to 504 adults aged 25 ≥years. Respondents made repeated choices between two hypothetical scans, described according to waiting time for scan and results, procedure type, the chance of minor side-effects, and whether further scanning procedures were likely to be required. Choice data were analyzed using mixed-logit models with respondent characteristics used to explain preference heterogeneity. Respondents preferred shorter waiting times, the procedure to be undertaken with a handheld scanner on a couch instead of within a body scanner, no side-effects, and no follow–up scans (p≤.01). The average respondent was willing to wait an additional 2 weeks for the scan if it resulted in avoiding side-effects, 1.5 weeks to avoid further procedures or to be told the results immediately, and 1 week to have the scan performed on a couch with a handheld scanner. However, substantial heterogeneity was observed in the strength of preference for desirable imaging characteristics. An average individual belonging to a general population sub–group most likely to require imaging to characterize focal liver lesions in the United Kingdom would prefer contrast–enhanced ultrasound over magnetic resonance imaging or computed tomography. Insights into the patient perspective around differential characteristics of imaging modalities have the potential to be used to guide recommendations around the use of these technologie

  20. Liver metastases: Sulphur hexafluoride-enhanced ultrasonography for lesion detection: a systematic review

    NARCIS (Netherlands)

    Cabassa, Paolo; Bipat, Shandra; Longaretti, Laura; Morone, Mario; Maroldi, Roberto

    2010-01-01

    This is a systematic review to evaluate the accuracy of contrast-enhanced ultrasonography (CEUS) performed with "SonoVue" (sulphur hexafluoride) in the detection of hepatic metastases. The MEDLINE, EMBASE and COCHRANE Databases were searched, regardless of language, for relevant articles published

  1. Ultrasonography and indium 111 white blood cell scanning for the detection of intraabdominal abscesses

    International Nuclear Information System (INIS)

    Carroll, B.; Silverman, P.M.; Goodwin, D.A.; McDougall, I.R.

    1981-01-01

    Ultrasound and indium 111 white blood cell scanning were performed on 163 patients with suspected intraabdominal abscesses. In all but one case, intraabdominal abscesses were correctly identified by one or both tests; conversely, no patient was falsely diagnosed by both tests to have an abscess. Sonography was useful in those patients with focal symptoms, and frequently identified nonabscess causes for fever. White cell scanning was valuable when focal signs were absent, and frequently identified extraabdominal sources of sepsis. The two imaging modalities are complementary and provide a highly accurate and sensitive means of intraabdominal abscess detection

  2. Automated SmartPrep tracker positioning in liver MRI scans

    International Nuclear Information System (INIS)

    Goto, Takao; Kabasawa, Hiroyuki

    2013-01-01

    This paper presents a new method for automated SmartPrep tracker positioning in liver MRI scans. SmartPrep is used to monitor the contrast bolus signal in order to detect the arrival time of the bolus. Accurately placing the tracker in the aorta while viewing three planar scout images is a difficult task for the operator and is an important problem from the workflow standpoint. The development of an automated SmartPrep tracker would therefore help to improve workflow in liver MRI scans. In our proposed method, the aorta is detected using AdaBoost (which is a machine learning technique) by searching around the cerebral spinal fluid (CSF) in the spinal cord. Analysis of scout scan images showed that our detection method functioned properly for a variety of axial MR images without intensity correction. A total of 234 images reconstructed from the datasets of 64 volunteers were analyzed, and the results showed that the detection error for the aorta was approximately 3 mm. (author)

  3. Evaluation of Hemodynamics in Focal Steatosis and Focal Spared Lesion of the Liver Using Contrast-Enhanced Ultrasonography with Sonazoid

    International Nuclear Information System (INIS)

    Shiozawa, K.; Watanabe, M.; Ikehara, T.; Kogame, M.; Shinohara, M.; Shinohara, M.; Ishii, K.; Igarashi, Y.; Sumino, Y.; Shiozawa, K.; Makino, H.

    2014-01-01

    We aim to investigate the hemodynamics in focal steatosis and focal spared lesion of the liver using contrast-enhanced ultrasonography (CEUS) with Sonazoid. The subjects were 47 patients with focal steatosis and focal spared lesion. We evaluated enhancement patterns (hyper enhancement, iso enhancement, and hypo enhancement) in the vascular phase and the presence or absence of a hypoechoic area in the post vascular phase for these lesions using CEUS. Of the 24 patients with focal steatosis, the enhancement pattern was iso enhancement in 19 and hypo enhancement in 5. Hypoechoic areas were noted in the post vascular phase in 3 patients. Of the 23 patients with focal spared lesions, the enhancement pattern was iso enhancement in 18 and hyper enhancement in 5. No hypoechoic areas were noted in the post vascular phase in any patient. The hemodynamics in focal steatosis and focal spared lesions in non diffuse fatty liver can be observed using low-invasive procedures in real-time by CEUS. It was suggested that differences in the dynamics of enhancement in the vascular phase of CEUS were influenced by the fat deposits in the target lesion, the surrounding liver parenchyma, and the third inflow.

  4. Role of B-scan ultrasonography in pre-operative cataract patients.

    Science.gov (United States)

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  5. Ultrasonography, angiography, computed tomography and magnetic resonance in nodular regenerative hyperplasia of the liver

    International Nuclear Information System (INIS)

    Patriarche, C.; Pelletier, G.; Attali, P.; Ladouch-Badre, A.; Fabre, M.; Roche, A.; Etienne, J.P.

    1988-01-01

    Ultrasonographic, computed tomographic, and angiographic abnormalities of nodular regenerative hyperplasia have been described in very few cases. We report here the case of a 50-year-old man with round, well-limited hypoechogenic lesions involving the two lobes of the liver, and hypervascular, poorly delineated angiographic lesions. Computed tomography and magnetic resonance of the liver were normal. Histological examination of large liver specimens provided by intraoperative biopsy allowed the diagnosis of nodular regenerative hyperplasia. Such a pseudo-tumoral ultrasonographic and angiographic pattern must be recognized in order to avoid diagnostic and therapeutic mistakes, especially since percutaneous liver biopsy usually fails to diagnose this disease. (author)

  6. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi

    1970-01-01

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ( 198 Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  7. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1970-09-15

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ({sup 198}Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  8. Focal hepatic steatosis: ultrasound and CT scan features may mimick carcinoma of the liver

    International Nuclear Information System (INIS)

    Monnin, J.L.; Blanc, F.; Guiry, P.; Bruel, J.M.; Monnin, E.; Ciurana, A.J.

    1988-01-01

    Ultrasound and CT scan features of focal hepatic steatosis (FHS) may closely resemble those of primary or secondary malignant hepatic tumors. Three cases of FHS in chronic alcoholics are reported. In two cases, the area of steatosis was hyperechogenic upon ultrasonography. In all three patients, CT scan demonstrated a hypodense image, with poor enhancement following opacification and no mass effect. Diagnosis of FHS was ascertained upon hepatic biopsy under CT scan guidance in all three patients [fr

  9. Diagnostic value of ultrasonography, infusion tomography of the gall-bladder and sup(99m)Tc-DIDA hepatobiliary scanning in cases of suspected acute cholecystitis

    Energy Technology Data Exchange (ETDEWEB)

    Holst Pedersen, J.; Hancke, S.; Christensen, B.; Gammelgaard, J.; Haubek, A.; Ingemann Jensen, L.; Munck, O.; Wied, U. (Koebenhavns amts sygehus i Herlev, kirurgisk gastroenterologisk afd., Herlev, Denmark)

    1982-01-01

    Ultrasonography, infusion tomography of the gall-bladder and sup(99m)Tc-diethyl acetanilide iminodiacetic acid (DIDA) hepatobiliary scanning were compared in a prospective investigation of 45 consecutive patients in whom acute cholecystitis was suspected clinically. The definitive diagosis of acute cholecystitis was established or excluded at operation in 35 patients, by oral cholecystography in five and by intravenous cholangiography in five. The predictive values of positive and negative results of investigation were 100% and 83%. respectively, with ultrasonography and 98% and 88%, respectively, in hepatobiliary scanning. The corresponding values for infusion tomography were 87% and 33%, respectively. It is concluded from these results that ultrasonography and sup(99m)Tc-DIDA hepatobiliary scanning are capable of establishing the diagnosis rapidly and with certainty in cases of suspected acute cholecystitis. A preliminary account of the results of routine employment of sup(99m)Tc-DIDA hepatobiliary scanning in 29 consecutive patients revealed no erroneous diagnoses. In the majority of patients with acute cholecystitis, operation proved possible within 48 hours of admission.

  10. Ultrasonography for diagnosis of alcoholic cirrhosis in people with alcoholic liver disease

    DEFF Research Database (Denmark)

    Pavlov, Chavdar S; Casazza, Giovanni; Semenistaia, Marianna

    2016-01-01

    , but people in whom hepatocellular carcinoma has developed are often co-infected with hepatitis B or C virus.Abstinence from alcohol may help people with alcoholic disease in improving their prognosis of survival at any stage of their disease; however, the more advanced the stage, the higher the risk...... with alcoholic liver disease; however, besides the difficulties of finding a suitable liver transplant organ, there are many other factors that may influence a person's survival.Ultrasound is an inexpensive method that has been used for years in clinical practice to diagnose alcoholic cirrhosis. Ultrasound...... Handbook for Systematic Reviews of Diagnostic Test Accuracy. MAIN RESULTS: The review included two studies that provided numerical data regarding alcoholic cirrhosis in 205 men and women with alcoholic liver disease. Although there were no applicability concerns in terms of participant selection, index...

  11. Liver-lung scan in the diagnosis of right subphrenic abscess

    International Nuclear Information System (INIS)

    Middleton, H.M. III; Patton, D.D.; Hoyumpa, A.M. Jr.; Schenker, S.

    1976-01-01

    To assess the value of liver-lung scanning in the diagnosis of right subphrenic abscess, 148 scans were reviewed against corresponding charts. Of 91 scans with adequate clinical data, overall scanning error was 19.3 percent with 14 false positive and 3 false negative scans. Among 49 scans (of the initial group of 91 studies) with presence or absence of actual pathology proved by surgery and/or autopsy, there were 3 true positive, 12 false positive, 29 true negative, and 3 false negative scans. Analysis of data indicated lower accuracy of scan interpretation than generally reported, low specificity for positive scans and high specificity for negative scans, correlation of false interpretations with atypical degrees of liver-lung separation and with scanning defects in liver and lung, and failure of rereading significantly to improve accuracy of interpretation

  12. Change perspective to increase diagnostic accuracy of ultrasonography in calcium pyrophosphate dihydrate deposition disease! A new approach: the axial scan of the meniscus

    Directory of Open Access Journals (Sweden)

    G. Filippou

    2015-03-01

    Full Text Available Ultrasonography (US is a relevant tool in the study of calcium pyrophosphate dihydrate (CPP deposition disease. However, differential diagnosis of hyperechoic deposits within the fibrocartilage can be difficult; moreover, US study is limited by the need of an adequate acoustic window. We describe a US scanning technique that offers a new viewpoint in the study of knee meniscal structure: a longitudinal scan performed according to the long axis of meniscus. This technique proves to be particularly useful for the identification of CPP deposition, but could also improve the US diagnostic utility and accuracy in other meniscal pathologies.

  13. Alcoholic liver injury: defenestration in noncirrhotic livers--a scanning electron microscopic study

    DEFF Research Database (Denmark)

    Horn, T; Christoffersen, P; Henriksen, Jens Henrik Sahl

    1987-01-01

    The fenestration of hepatic sinusoidal endothelial cells in 15 needle biopsies obtained from chronic alcoholics without cirrhosis was studied by scanning electron microscopy. As compared to nonalcoholics, a significant reduction in the number of fenestrae and porosity of the sinusoidal lining wall...... (fractional area of fenestrae) was observed in acinar Zone 3, both in biopsies with and without Zone 3 fibrosis as judged by light microscopy. A significant reduction of porosity as shown in this study may influence the blood hepatocytic exchange and contribute to the alcohol-induced liver injury....

  14. The study on fatty infiltration of the liver with the use of CT scan

    International Nuclear Information System (INIS)

    Yamawaki, Tadaharu; Hirofuji, Hideo; Yatomi, Akira; Kawabe, Masami; Sugie, Hajime

    1981-01-01

    On the basis of experience thus far, it is said that the diagnosis of fatty liver is comparatively difficult. It has been reported that the diagnosis of fatty liver can be done by its decreased attenuation number on CT scan among diffuse liver diseases. We investigated 80 cases of which attenuation number revealed below 35 Hn (Hounsfield units). Analysis of correlations between eight variables (T. Cholesterol, β-lipoprotein, Triglyceride, HDL Cholesterol, Cholinesterase, Obsity index, BSP and the degree of fatty infiltration of the liver specimen) and mean attenuation number of the liver were investigated and highly significant correlation was found only between the degree of fatty infiltration of the liver and the mean attenuation number of the liver (r = -0.746, p < 0.01). Therefore, it is concluded that CT scan is an epochmaking morphological examination of fatty liver. (author)

  15. A Study on Liver Scan using 113mIn Colloid

    International Nuclear Information System (INIS)

    Koh, Chang Soon; Rhee, Chong Hoen; Chang, Kochang; Hong, Chang Gi

    1969-01-01

    There have been reported numberous cases of liver scanning in use of 198 Au colloid by many investigators, however, one in use of 113m In colloid has not been reported as yet in this country. The dose of 113 mIn for high diagnostic value in examination of each organ was determined and the diagnostic interpretability of liver scanning with the use of 113m In was carefully evaluated in comparison with the results of the liver scanning by the conventionally applied radioisotope. The comparative study of both figures of liver scanning with the use of 113m In colloid and 198 Au colloid delivered following results:1) The liver uptake rate and clearance into peripheral blood were accentuated more in case of 113m In colloid than in case of 198 Au colloid. 2) The interpretability of space occupying lesion in liver scanning with 113m In was also superior to one with 198 Au. 3) The figure of liver scanning with 113m In colloid corresponds not always to the figure with 198 Au. This difference can be explained by difference of phagocytic ability of reticuloendothelial system within liver. 4) In the liver scanning with 113m In colloid, the spleen is also visualized even in normal examine. 5) In the cases of disturbed liver function, uptake is more decreased in use of 113m In colloid than in 198 Au, in the spleen, however, the way is contrary. 6) With use of 113m In colloid, the time required for scanning could be shortened in comparison with 198 Au. 7) The filtration of 113m In colloid for scanning prior to human administration gives an expectation for better scanning figure.

  16. Correlation of single image Tc-99m MIBI scan and ultrasonography with fine needle aspiration cytology (FNAC) to assess neoplasia in solitary 'cold' thyroid nodules

    International Nuclear Information System (INIS)

    Sohaib, M.; Saeed, S.; Naseeb, H.K.; Hyder, S.W.

    2007-01-01

    Various investigative approaches for the management of solitary thyroid nodules have been adopted, which involve Tc-99m pertechnetate scan, ultrasonography and fine needle aspiration cytology (FNAC). Incidence of neoplasm in a solitary thyroid nodule showing cold lesion on Tc-99m pertechnetate scan vary from 9 to 26%. In the current study we evaluated the utility of Tc-99m labeled Hexakis2- methoxyisobutyl isonitrile (Tc-99m MIBI) in differentiating neoplastic from non-neoplastic lesions among nodules which are cold on Tc-99m pertechnetate scan and solid or mixed on ultrasonography. Forty-nine patients, all having solitary cold nodules on Tc-99m Pertechnetate scans were included in the study. All underwent ultrasonography, Tc- 99m MIBI scan and FNAC. Ultrasound findings were categorized as solid, mixed and cystic. Anterior images of thyroid were acquired 15 minutes after intravenous injection of Tc-99m MIBI. The thyroid nodules were classified into 5 categories depending on the degree of MIBI uptake. They were; Category-1 showing intense uptake, Category -2 showing slightly higher uptake than the surrounding normal thyroid tissue, Category - 3 with uptake equal to the normal thyroid, Category -4 showing less uptake than the surrounding normal tissue and Category -5 showing no or negligible uptake of Tc-99m MIBI. Receiver Operating Characteristic (ROC) curve was generated using Tc-99m MIBI results. FNAC revealed 10 nodules with neoplastic lesions (8 follicular and two pleomorphic), 29 with colloid goiter and 5 with benign cystic lesions. Tc-99m MIBI images revealed Categories- 1,2,3,4 and 5 scintigraphic patterns in 2,12, 11, 10 and 14 patients respectively. One patient in Category 1 and 9 in Category 2 proved to be neoplastic in nature, while none of the patients in category 3 to 5 had evidence of neoplasm on FNAC. The ROC curve revealed excellent performance of Tc-99m MIBI scan in diagnosing neoplastic lesions in the solitary cold thyroid nodules. Considering

  17. The sinusoidal lining cells in "normal" human liver. A scanning electron microscopic investigation

    DEFF Research Database (Denmark)

    Horn, T; Henriksen, Jens Henrik Sahl; Christoffersen, P

    1986-01-01

    The scanning electron microscopic was used to study the fenestrations of human liver sinusoids. Thirteen biopsies, where light microscopy and transmission electron microscopy revealed normal sinusoidal architecture, were investigated. The number of fenestrae was calculated in acinar zone 3...

  18. Pulmonary uptake of 198Au during liver scanning in two patients with amyloidosis

    International Nuclear Information System (INIS)

    Goebel, R.

    1976-01-01

    Lung uptake of 198 Au-colloid, injected for a liver scan, is demonstrated in two patients with systemic amyloidosis. The incidence, importance and mechanism of this phenomenon is discussed. (orig.) [de

  19. A Study of Technical Approach Methods to Transabdominal Ultrasonography of the Extrahepatic Bile Ducts and of Following Effects from the Scan Training

    International Nuclear Information System (INIS)

    Lee, In Ja; Kang, Dae Hyun; Kim, Bo Young

    2008-01-01

    The purposes of this study are to analyze abnormal dilatation of the extrahepatic bile ducts by using transabdominal ultrasound, to confirm the existence of bile ducts diseases and their interrelationship, and for it to give a new theoretical basis for the technical access to extrahepatic bile ducts, upon which to analyze the ripple effects of the scan training. After teaching technical access process based on the new theory about extrahepatic bile duct to the thirty students who are studying ultrasonography, we allocated three hours per one student (30 mins 6 times) to focus on the training of scanning skill. Training has been performed by one-to-one method. For evaluation, all the students have to perform the scans on (1) confluence of the right and left hepatic ducts (extrahepatic bile ducts and cystic duct), (2) the suprapancreatic bile duct, (3) the intrapancreatic bile duct, (4) intrapapilla Duct, based on the clearly divided concept. The existing training and methods have had low confidency about transabdominal ultrasonography of the extrahepatic bile duct and had limitation with which they could image only the suprapancreatic bile duct. The evaluation after finishing the train based on the new theory, however, all the students (30 students) can access to (1) confluence of the right and left hepatic ducts(extrahepatic bile ducts and cystic duct), (2) the suprapancreatic bile duct objectively. 24 students can access to (3) the intrapancreatic bile duct and only one student can even make an image for (4) the intrapapilla Duct Though the evaluation on extrahepatic bile duct has to be performed with multi-sided method considering intrahepatic cause, bile duct cause and pathophysiological cause, only if we can image the extrahepatic bile duct to ampular of Vater objectively and confidently, we can greatly reduce invasive procedure such as ERCP, which is for the purpose of simple differential diagnosis and painful to the patients. Therefore if we concentrate on

  20. A Study on the Effects of Position Change on the Liver Shape on Radioisotope Scan

    International Nuclear Information System (INIS)

    Hong, Kee Suk; Choi, Du Hyok; Yang, Young Tae; Koh, Chang Soon

    1982-01-01

    For this study, the authors obtained and examined anterior views of the liver and spleen in two different positions, upright and supine, of 39 normal subjects and 20 patients with hepatic pathology by means of 99m Tc-colloid and gamma camera. This examination confirms the following findings. In general, it is shown, left lobe of the liver in upright position becomes longer in height than in supine position, while the distance between lateral margin of the liver and that of spleen becomes father in with in supine position than in upright position. The upper margin of liver moves more downward in upright position than in supine. It is noticeable that as for 5 cases with severe chronic liver disease, there is minimal alteration of the liver shape between in two positions. The comparison of the both positions for the better liver scan shows the following findings. Prominent caudate and/or left lobe are marked in the upright position in 16 cases out of the total 59, while none is found in the supine. The false cold area in lower part of the liver disappears in 7 cases in the upright position, while only one shows the disappearance of the false cold area in the supine. Left liver margin due to close contact of spleen is blurred in 3 cases in the upright position. In total 23 cases out of 59 support that the upright position is better for the liver scan, while only 4 cases support the supine position is better. These findings support two assumptions. One is that upright view can be expected more improved resolution than supine view for liver scan. Second is that minimal change of the liver shape in both views indicate the serious abnormality in the liver.

  1. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    International Nuclear Information System (INIS)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun; Shin, Sang Soo; Ahn, Kyu Youn

    2017-01-01

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities

  2. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Shin, Sang Soo [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Ahn, Kyu Youn [Dept. of Anatomy, Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2017-01-15

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities.

  3. Value of liver scan in the follow-up study of patients with adenocarcinoma of the colon and rectum

    International Nuclear Information System (INIS)

    Cedermark, B.J.; Schultz, S.S.; Bakshi, S.; Parthasarathy, K.L.; Mittelman, A.; Evans, J.T.

    1977-01-01

    Seventy consecutive patients with adenocarcinoma of the colon and rectum had a liver scan followed by surgical exploration of the liver. Preoperatively, blood chemistry studies were done in addition to palpation of the abdomen. Surgical findings were correlated to results of the liver scans, function tests and palpation of the liver. The overall concordance of liver scans with surgical findings was 78 percent. Thirty percent had false-positive results and 15 percent, false-negative results. The correlation of the liver scan with surgical findings was improved with increasing extent of metastases. When less than 25 percent of the liver was replaced by tumor, there was a random correlation of scan to surgical findings. By combining liver scans and liver function tests, metastases could be predicted with increased reliability only in patients who had severe metastatic disease of the liver. It is strongly recommended that patients with liver scans suggestive of metastatic disease and with most liver function tests within normal limits undergo exploration to establish the diagnosis. Exploratory laparotomy seems to be the only way to avoid chemotherapeutic treatment of patients with false-positive scans and still allow detection and treatment of metastases to the liver to occur at earlier stages

  4. Diagnostic values of FibroScan and FibroTouch for liver fibrosis: a comparative analysis

    Directory of Open Access Journals (Sweden)

    WU Na

    2014-07-01

    Full Text Available ObjectiveTo compare the diagnostic values of FibroScan and FibroTouch for liver fibrosis. MethodsA total of 962 patients who visited Department of Hepatology, The First Hospital of Jilin University from September 2013 to March 2014 were enrolled. FibroScan and FibroTouch were performed among these patients. Thirty-three cases underwent liver biopsy, and Aspartate aminotransferase-to-platelet ratio index (APRI was calculated in 66 patients (chronic hepatitis B (CHB: 53 cases; chronic hepatitis C (CHC: 13 cases. Spearman rank correlation test was used to analyze the correlation between the results measured by FibroScan and FibroTouch. The diagnostic values of FibroScan and FibroTouch for liver fibrosis were analyzed and compared by receiver operating characteristic (ROC curve. ResultsThe analysis of liver stiffness measured by FibroScan and FibroTouch among all patients showed that the correlation coefficient between FibroScan and FibroTouch was 0.866 (P<0.05, n=962. FibroScan and FibroTouch were significantly correlated with APRI (r=0.58 and 0.63, P<0.05, n=66 and pathological stage determined by liver biopsy (r=0.67 and 0.74, P<0.05, n=33. Among patients with CHB, for the diagnosis of APRI ≥2 (liver cirrhosis, the areas under the ROC curve (AUCs of FibroScan and FibroTouch were 0.761 vs 0.728 (P=0.61; among patients with CHC, for the diagnosis of APRI ≥1 (liver cirrhosis, the AUCs of FibroScan and FibroTouch were 0.810 vs 0.893 (P=0.38. For pathological stages ≥S1, ≥S2, ≥S3, and ≥S4, the AUCs of FibroScan and FibroTouch were 0.830 vs 0.889 (P=0.15, 0.841 vs 0.835 (P=0.90, 0.888 vs 0.920 (P=0.43, and 0.964 vs 0.979 (P=0.45, respectively. ConclusionFibroScan and FibroTouch have comparable diagnostic values for liver fibrosis. However, the number of cases undergoing liver biopsy in this study was relatively small, and investigation of more cases is needed to make further confirmation.

  5. Liver scanning in the diagnosis of metastases from malignant tumors of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Fleites, G.; Gomez, E.; Bell, L.; Peralta, R.; Suarez, J.C.; Cassola, J.R.; Fraga, A.

    1989-01-01

    The National Institute of Oncology and Radiobiology (INOR) established a line of clinical investigation in January, 1974, which was later added to clinical care. This line consisted of trying to arrive at a preoperative diagnosis - by means of liver scanning - of the potential liver metastases of primitive tumors in the gastrointestinal tract. Metastable 113 Indium was used. A review of the results obtained in the 50 patients included in the investigation program is made. The results of preoperative scanning were compared with operative findings. Twelve liver metastases (24%) were found. In 40 patients there was agreement (80%) between preoperative scanning and operatory findings. At present, ultrasound is a necessary supplement to scans, which supplements it but does not exclude it. The tracer element used now is technetium-99 M coloidal sulphide

  6. Ultrasonography of polycystic kidney

    International Nuclear Information System (INIS)

    Oh, Seung Chul; Cho, Seung Gi; Lee, Kwan Seh; Kim, Kun Sang

    1980-01-01

    Polycystic disease is defined as a heritable disorder with diffuse involvement of both kidneys. The term 'Polycystic disease' comprises at least two separate, genetically different disease-one with an onset typically in childhood (infantile polycystic disease) and the other with an onset typically in adulthood (adult polycystic disease). Adult polycystic kidney disease is the most common form of cystic kidney disease in humans. Ultrasonography is a very useful noninvasive diagnostic modality in the patient with clinically suspected renal diseases as well as screening test. 14 cases of ultrasonography in patient with polycystic kidney were reviewed. All cases show unilateral or bilateral enlarged kidneys. 7 cases reveal kidneys and liver replaced by multiple cysts of varing size. Screening ultrasonography for a familial tree is reported

  7. Inflammatory pseudotumours of the liver--role of dynamic MRI scan and surgical exploration.

    LENUS (Irish Health Repository)

    Hasan, W

    2011-02-01

    Inflammatory pseudotumours of the liver are extremely rare benign lesions. They were first described by Pack and Baker in 1953. They usually present with raised inflammatory markers and nonspecific abdominal symptoms. Most of these lesions are picked up incidentally on ultrasound scans. Diagnosis of these lesions poses a dilemma and a challenge due to their radiological similarities to other liver lesions such as hepatocellular carcinoma HCC. In this article we describe our experience in its diagnosis and management.

  8. Correlation of Major Scan Findings and Esophageal Varices in Liver Cirrhosis

    International Nuclear Information System (INIS)

    Ahn, J. S.; Bahk, Y. W.; Lim, J. L.

    1970-01-01

    In an endeavor to help understand some typical scan findings and portal hemodynamics in liver cirrhosis, several commonly occurring scan changes and esophageal varices as demonstrated by esophagram were correlated one another from quantitative and qualitative stand points. Clinical materials consisted of 34 patients with proven diagnosis of liver cirrhosis and esophageal varices. Liver scan was performed with colloidal 198-Au and the changes in the size and internal architecture of the Liver, splenic uptake and splenomegaly were graded and scored by repeated double-blind readings. The variceal changes on esophagrams were also graded according to the classification of Shanks and Kerley following modification. Of 34 patients, 91% showed definite reducing in liver volume(shrinkage) constituting the most frequent scan change. The splenic uptake and splenomegaly were noted in 73.5 and 79.4%, respectively. The present study revealed no positive correlation between the graded scan findings including shrinkage of the liver, splenic uptake or splenomegaly and severity of variceal changes of the esophagus. Exceptionally, however, apparently paradoxical correlation was noted between the severity of mottling and varices. Thus, in the majority(73.5%) of patients mottling were either absent or mild. This interesting observation is in favor of the view held by Christie et al. who consider the mottlings to be not faithful expression of actual scarring of the cirrhosis liver. This also would indicate that variceal changes are to be the results of intrahepatic arteriovenous shunting of blood with hypervolemic load to the portal system rather than simple hypertension secondary to fibrosis and shrinkage.

  9. Correlation of Major Scan Findings and Esophageal Varices in Liver Cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J S; Bahk, Y W; Lim, J L [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1970-03-15

    In an endeavor to help understand some typical scan findings and portal hemodynamics in liver cirrhosis, several commonly occurring scan changes and esophageal varices as demonstrated by esophagram were correlated one another from quantitative and qualitative stand points. Clinical materials consisted of 34 patients with proven diagnosis of liver cirrhosis and esophageal varices. Liver scan was performed with colloidal 198-Au and the changes in the size and internal architecture of the Liver, splenic uptake and splenomegaly were graded and scored by repeated double-blind readings. The variceal changes on esophagrams were also graded according to the classification of Shanks and Kerley following modification. Of 34 patients, 91% showed definite reducing in liver volume(shrinkage) constituting the most frequent scan change. The splenic uptake and splenomegaly were noted in 73.5 and 79.4%, respectively. The present study revealed no positive correlation between the graded scan findings including shrinkage of the liver, splenic uptake or splenomegaly and severity of variceal changes of the esophagus. Exceptionally, however, apparently paradoxical correlation was noted between the severity of mottling and varices. Thus, in the majority(73.5%) of patients mottling were either absent or mild. This interesting observation is in favor of the view held by Christie et al. who consider the mottlings to be not faithful expression of actual scarring of the cirrhosis liver. This also would indicate that variceal changes are to be the results of intrahepatic arteriovenous shunting of blood with hypervolemic load to the portal system rather than simple hypertension secondary to fibrosis and shrinkage.

  10. Dose to the liver and spleen in pediatric patients undergoing technetium-99m sulfur colloid scans

    International Nuclear Information System (INIS)

    Thomas, S.R.; Purdom, R.C.; Kereiakes, J.G.; Gelfand, M.J.; Maxon, H.R.

    1979-01-01

    Quantitative conjugate view external counting techniques were applied to determine radiation dose to the liver and spleen in pediatric patients undergoing /sup 99m/Tc-sulfur colloid (Tc-SC) liver scans. The effective half-life of /sup99m/Tc-SC was 5.8 +- 0.23 hours and 5.2 +- 0.68 hours in the liver and spleen, respectively. Dose per administered activity ranged from 0.34 to 0.63 rad/mCi (92 to 170 μGy/MBq) for the liver and 0.35 to 1.96 rad/mCi (95.0 to 530.0 μGy/MBq) for the spleen. The spleen to liver dose ratio ranged from 1.0 to 4.9. These values are compared with results extrapolated from published adult data to the pediatric population

  11. Liver scanning using indium-113m at the University Teaching Hospital, Lusaka, Zambia

    Energy Technology Data Exchange (ETDEWEB)

    Mulaisho, C [Nuclear Medicine Unit, Department of Medicine, University of Zambia, Lusaka, Zambia; Mumba, K N [Radio-isotope Research Unit, National Council for Scientific Research, Lusaka, Zambia

    1981-11-21

    Liver scanning using the radio-isotope indium-113m, can now be routinely perfomed at the University Teaching Hospital, Lusaka, Zambia. The dose used is 1 - 4 mCi. Liver scans have been performed on 48 subjects, including 10 healthy individuals 16 patients with histologically proven hepatocellular carcinoma, 11 with clinical and laboratory evidence of portal hypertension and 11 with miscellaneous illnesses. Seven representative scans are illustrated. The procedure is easy, and gives a fairly accurate functional estimate of Kupffer cell mass. In hepatoma the scan may be either larger than or smaller than normal and reflects more accurately the residual function of the Kupffer cells. In cirrhosis of the liver with portal hypertention, residual Kupffer cell mass is small. Consequently, most of the indium-113m is taken up by the splenic reticulo-endothelial system, resulting in a large spleen scan. This technique, although fraught with major limitations, is a useful additional diagnostic tool in the management of chronic liver disease.

  12. The ''liver scan'' appearance in cholescintigraphy. A sign of complete common bile duct obstruction

    International Nuclear Information System (INIS)

    Noel, A.W.; Velchik, M.G.; Alavi, A.

    1985-01-01

    One hundred consecutive Tc-99m IDA hepatobiliary scans were reviewed revealing 14 scans (14%), that showed nonvisualization of the common bile duct (CBD), gallbladder (GB), and small bowel (SB), but good hepatic uptake of Tc-99m IDA derivative, a pattern designated by us as ''the liver scan appearance.'' In 11 of 14 cases (79%), the diagnosis of complete CBD obstruction was confirmed by surgery, percutaneous transhepatic cholangiogram (PTC), endoscopic retrograde cholangiopancreatography (ERCP), and/or percutaneous needle biopsy (PBx). Common bile duct obstruction was suspected but not proven in the other three cases. The cholescintigraphic, ultrasound, PTC, ERCP, intraoperative cholangiogram, clinical, laboratory, and surgical findings are presented and correlated. The ''liver scan-appearance'' by cholescintigraphy should suggest a diagnosis of complete common bile duct obstruction; however, it does not specifically differentiate between stone or tumor as the cause of obstruction

  13. Reducing radiation dose in liver enhanced CT scan by setting mAs according to plain scan noise

    International Nuclear Information System (INIS)

    Yang Shangwen; He Jian; Yang Xianfeng; Zhou Kefeng; Xin Xiaoyan; Hu Anning; Zhu Bin

    2013-01-01

    Objective: To investigate the feasibility of setting mAs in liver enhanced CT scan according to plain scan noise with fixed mA CT scanner, in order to reduce the radiation dose. Methods: One hundred continuous patients underwent liver enhanced CT scan (group A) prospectively. Two hundred and fifty mAs was used in plain and enhanced CT scans. Noises of plain and venous phase CT images were measured, and the image quality was evaluated. The equation between mAs of enhanced scan and noise of plain scan image was derived. Another 100 continuous patients underwent liver enhanced CT scan (group B). Enhanced scan mAs was calculated from noise on plain scan by using the equation above. Noises on venous phase images were measured and the image quality was measured. Based on body mass index (BMI), patients in groups A and B were divided into three subgroups respectively: BMI < 18.5 kg/m 2 , 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 and BMI ≥ 25.0 kg/m 2 . Image quality score was compared with nonparametric rank sum test, CT dose index (CTDI) and effective dose (ED) were measured and compared between each subgroup with 2 independent samples t or t' test. Results: The equation between enhanced scan mAs (mAsX) and plain scan noise (SDp) was as follows: mAsX = mAs1 × [(0.989 × SDp + 1.06) /SDx] 2 , mAs1 = 250 mAs, SDx = 13. In patients with BMI < 18.5 kg/m 2 , ED of group A [(6.86 ± 0.38) mSv, n = 12] was significantly higher than group B [(2.66 ± 0.46) mSv, n = 10)] (t = 18.52, P < 0.01). In patients with 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 , ED of group A [(7.08 ± 0.91) mSv, n = 66] was significantly higher than group B [(4.50 ± 1.41) mSv, n = 73] (t' = 10.57, P < 0.01). In patients with BMI ≥ 25.0 kg/m 2 , there was no significant difference between EDs of group A (7.54 ± 0.62 mSv, n = 22) and group B [(8.19 ± 3.16) mSv, n = 17] (t' = 0.89, P = 0.39). Image quality of 5 patients in group A and none in group B did not meet the diagnostic requirement

  14. Registration accuracy and image quality of time averaged mid-position CT scans for liver SBRT

    NARCIS (Netherlands)

    Kruis, Matthijs F.; van de Kamer, Jeroen B.; Sonke, Jan-Jakob; Jansen, Edwin P. M.; van Herk, Marcel

    2013-01-01

    The purpose was to validate the accuracy of motion models derived from deformable registration from four-dimensional computed tomography (4DCT) and breath-hold contrast enhanced computed tomography (BHCCT) scans for liver SBRT. Additionally, the image quality of the time averaged mid-position (MidP)

  15. Technetium-99m labeled radiodiagnostic agents for liver and bone marrow scanning and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Peacock, F.R.

    1977-01-01

    An improved technetium-99m labeled colloid and method of preparation comprising reducing technetium-99m with stannous oxalate and stabilizing with sodium phytate are described. This radiodiagnostic agent is useful in the scintigraphic examination of the reticuloendothelial system, particularly the liver. In addition, by autoclaving this product with saline, it becomes a superior bone marrow scanning agent

  16. Clinical Applicability of Transient Elastography for Estimating Liver Stiffness in Patients with Type 2 Diabetes Mellitus

    NARCIS (Netherlands)

    Van Dijk, P. R.; Landman, G. W. D.; Hoving, S.; Kleefstra, N.; Bilo, H. J. G.; Groeneveld, P. H. P.

    2016-01-01

    Background: Type 2 diabetes mellitus (T2DM) is a risk factor for the development of non-alcoholic fatty liver disease, which can lead to liver fibrosis and ultimately to cirrhosis. Transient elastography (TE), by using the FibroScan, and is a non-invasive ultrasonography method to measure liver

  17. Vascular anatomy of the liver and porta hepatis with dynamic CT scan

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Wada, Mitsuyoshi; Nakajima, Teiichi; Tonooka, Reiko; Matsumoto, Kunihiko

    1983-01-01

    Vascular anatomy of the liver and porta heaptis demonstrated by dynamic CT scan was studied Identification of the individual vessels was sometimes difficult due to slight differencies in respiratory depths among the scans. Limitation in the number of slices also made the evalution of the vascular anatomy difficult. Angiography was therefore utilized for comparison in identifying the vessels. Dynamic CT scan was proved to be usefull in demonstrating the anteroposterior relationship of the vessels and surrounding structures, which is difficult with convetional angiography without multiple projections. Three dimensional understanding of the vessels was then possible with dynamic CT scan and angiography. When combined with recently advancing digital subtraction angiography, dynamic CT scan might reduce the necessity for conventional angiography with Seldinger's technique. (author)

  18. Controlled attenuation parameter using the FibroScan® XL probe for quantification of hepatic steatosis for non-alcoholic fatty liver disease in an Asian population.

    Science.gov (United States)

    Chan, Wah-Kheong; Nik Mustapha, Nik Raihan; Wong, Grace Lai-Hung; Wong, Vincent Wai-Sun; Mahadeva, Sanjiv

    2017-02-01

    The FibroScan® XL probe reduces failure of liver stiffness measurement (LSM) and unreliable results in obese patients. The objective of this article is to evaluate the accuracy of controlled attenuation parameter (CAP) obtained using the XL probe for the estimation of hepatic steatosis in patients with non-alcoholic fatty liver disease (NAFLD). Adult NAFLD patients with a liver biopsy within six months were included and were examined with the FibroScan® M and XL probes. Histopathological findings were reported according to the Non-Alcoholic Steatohepatitis Clinical Research Network Scoring System. Participants who did not have fatty liver on ultrasonography were recruited as controls. A total of 57 NAFLD patients and 22 controls were included. The mean age of the NAFLD patients and controls was 50.1 ± 10.4 years and 20.2 ± 1.3 years, respectively ( p  = 0.000). The mean body mass index was 30.2 ± 5.0 kg per m 2 and 20.5 ± 2.4 kg per m 2 , respectively ( p  = 0.000). The distribution of steatosis grades were: S0, 29%; S1, 17%; S2, 35%; S3, 19%. The AUROC for estimation of steatosis grade ≥ S1, S2 and S3 was 0.94, 0.80 and 0.69, respectively, using the M probe, and 0.97, 0.81 and 0.67, respectively, using the XL probe. CAP obtained using the XL probe had similar accuracy as the M probe for the estimation of hepatic steatosis in NAFLD patients.

  19. Intermittent clamping of the hepatic pedicle in simultaneous ultrasonography-guided liver resection and colorectal resection with intestinal anastomosis: is it safe?

    Science.gov (United States)

    De Raffele, Emilio; Mirarchi, Mariateresa; Vaccari, Samuele; Cuicchi, Dajana; Lecce, Ferdinando; Dalla Via, Barbara; Cola, Bruno

    2014-12-01

    In patients with colorectal cancer (CRC) and synchronous colorectal liver metastases (CRLM) potentially candidates to combined liver (LR) and colorectal resection (CRR), the extent of LR and the need of hepatic pedicle clamping (HPC) in selected cases are considered risk factors for the outcome of the intestinal anastomosis. This study aimed to determine whether intermittent HPC is predictive of anastomotic leakage (AL) and has an adverse effect on the clinical outcome in patients undergoing combined restorative CRR and LR. One hundred six LR have been performed for CRLM in our unit from July 2005. Patients who received CRR with anastomosis and simultaneous intraoperative ultrasonography (IOUS)-guided LR/ablation for resectable CRLM were included in this study. CRR was performed first. Intermittent HPC was decided at the discretion of the liver surgeon. The perioperative outcome was evaluated according to occurrence of AL and overall postoperative morbidity and mortality. Thirty-eight patients underwent simultaneous IOUS-guided LR/ablation and CRR with intestinal anastomosis; 19 underwent intermittent HPC (group ICHPY) while 19 did not (group ICHPN); the mean ± SD (range) duration of clamping in group ICHPY was 58.6 ± 32.2 (10.0-125.0) min. Postoperative results were similar between groups. One asymptomatic AL occurred in group ICHPY (5.2 %). Major postoperative complications were none in group ICHPY and one (5.2 %) in group ICHPN, respectively. One patient in group ICHPY died postoperatively (5.2 %). This study suggests that intermittent HPC during LR is not predictive of AL and has no adverse effect on the overall clinical outcome in patients undergoing combined restorative colorectal surgery and hepatectomy for advanced CRC.

  20. Combined endeavor of Neutrosophic Set and Chan-Vese model to extract accurate liver image from CT scan.

    Science.gov (United States)

    Siri, Sangeeta K; Latte, Mrityunjaya V

    2017-11-01

    Many different diseases can occur in the liver, including infections such as hepatitis, cirrhosis, cancer and over effect of medication or toxins. The foremost stage for computer-aided diagnosis of liver is the identification of liver region. Liver segmentation algorithms extract liver image from scan images which helps in virtual surgery simulation, speedup the diagnosis, accurate investigation and surgery planning. The existing liver segmentation algorithms try to extort exact liver image from abdominal Computed Tomography (CT) scan images. It is an open problem because of ambiguous boundaries, large variation in intensity distribution, variability of liver geometry from patient to patient and presence of noise. A novel approach is proposed to meet challenges in extracting the exact liver image from abdominal CT scan images. The proposed approach consists of three phases: (1) Pre-processing (2) CT scan image transformation to Neutrosophic Set (NS) and (3) Post-processing. In pre-processing, the noise is removed by median filter. The "new structure" is designed to transform a CT scan image into neutrosophic domain which is expressed using three membership subset: True subset (T), False subset (F) and Indeterminacy subset (I). This transform approximately extracts the liver image structure. In post processing phase, morphological operation is performed on indeterminacy subset (I) and apply Chan-Vese (C-V) model with detection of initial contour within liver without user intervention. This resulted in liver boundary identification with high accuracy. Experiments show that, the proposed method is effective, robust and comparable with existing algorithm for liver segmentation of CT scan images. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Analysis of one thousand liver scans carried out using technetium phytate

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, J; de Laforte, C; Roux, F; Bisset, J P; Paulin, R [Centre Hospitalier Universitaire de la Timone, 13 - Marseille (France)

    1977-10-01

    One thousand liver scans were carried out using technetium phytate. This soluble compound is transformed in the circulating blood into a colloid by chelation of serum calcium, thereby forming a macromolecular phytate of calcium and technetium. The presenting symptoms are compared with the isotopic findings. This microcolloid has the advantages common to all technetium tracers and, in addition, is easy to prepare and has the advantage of a distribution between the liver, spleen, and bone of the same type as that seen with colloidal gold 198 without the dosimetric problems associated with the latter. Although it has a level of hepatic fixation which is less than that of certain sulphide complexes of technetium it appears to provide a better reflection of the colloidopexic function of the liver.

  2. Analysis of one thousand liver scans carried out using technetium phytate

    International Nuclear Information System (INIS)

    Pasquier, J.; Laforte, C. de; Roux, F.; Bisset, J.P.; Paulin, R.

    1977-01-01

    One thousand liver scans were carried out using technetium phytate. This soluble compound is transformed in the circulating blood into a colloid by chelation of serum calcium, thereby forming a macromolecular phytate of calcium and technetium. The presenting symptoms are compared with the isotopic findings. This microcolloid has the advantages common to all technetium tracers and, in addition, is easy to prepare and has the advantage of a distribution between the liver, spleen and bone of the same type as that seen with colloidal gold 198 without the dosimetric problems associated with the latter. Although it has a level of hepatic fixation which is less than that of certain sulphide complexes of technetium it appears to provide a better reflection of the colloidopexic function of the liver [fr

  3. A case report with atypical liver-spleen scan after splenectomy

    International Nuclear Information System (INIS)

    Gokcora, N.; Ilgin, N.; Basaklar, C.

    1992-01-01

    Remodeling of the liver following splenectomy may simulate hypertrophy of an accessory spleen on sulphur colloid scans. There are but a few reports about the persistent splenic activity as a prominent finding during the post-splenectomy period. Splenic simulation may be attributed to the unusual hepatic lobe displacement, as in this case. The clinician should be aware of possible splenic simulation in the post-splenectomy period, if hypersplenism is suspected

  4. Early quantification of the therapeutic efficacy of the vascular disrupting agent, CKD-516, using dynamic contrast-enhanced ultrasonography in rabbit VX2 liver tumors

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Ijin; Kim, Jung Hoon; Lee, Jeong Min; Choi, Jin Woo; Han, Joon Koo; Choi, Byung Ihn [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-03-15

    To evaluate the usefulness of dynamic contrast-enhanced ultrasonography (DCE-US) in the early quantification of hemodynamic change following administration of the vascular disrupting agent (VDA) CKD-516 using a rabbit VX2 liver tumor model. This study was approved by our institutional animal care and use committee. Eight VX2 liver-tumor-bearing rabbits were treated with intravenous CKD-516, and all underwent DCE-US using SonoVue before and again 2, 4, 6, and 24 hours following their treatment. The tumor perfusion parameters were obtained from the time-intensity curve of the DCE-US data. Repeated measures analysis of variance was performed to assess any significant change in tumor perfusion over time. Relative changes in the DCE-US parameters between the baseline and follow-up assessments were correlated with the relative changes in tumor size over the course of seven days using Pearson correlation. CKD-516 treatment resulted in significant changes in the DCE-US parameters, including the peak intensity, total area under the time-intensity curve (AUCtotal), and AUC during wash-out (AUCout) over time (P<0.05). Pairwise comparison tests revealed that the AUCtotal and AUC during wash-in (AUCin) seen on the two-hour follow-up were significantly lower than the baseline values (P<0.05). However, none of early changes in the DCE-US parameters until 24-hour follow-up showed a significant correlation with the relative changes in tumor size during seven days after CKD-516 treatment. Our results suggest that a novel VDA (CKD-516) can cause disruption of tumor perfusion as early as two hours after treatment and that the therapeutic effect of CKD-516 treatment can be effectively quantified using DCE-US.

  5. Ultra-sonografia do fígado, aparelho renal e reprodutivo da jibóia (Boa constrictor Ultrasonography of the liver, renal and reproductive apparatus of Boa constrictor Snake

    Directory of Open Access Journals (Sweden)

    Francisco C. P. Neto

    2009-04-01

    Full Text Available Atualmente os animais silvestres têm despertado o interesse particular na criação domestica. Na medicina de animais selvagens, os exames ultra-sonográficos podem ser considerados como ferramenta para diagnosticar e prevenir doenças. Deste modo, realizou-se um estudo em 20 jibóias (Boa constrictor, a fim de caracterizar a morfologia e aparência ultra-sonográfica das estruturas presentes da cavidade celomática desses animais. Ultra-sonograficamente, o fígado apresentou-se variando de hipoecóica a levemente hiperecogênica, com margens ecogênicas e ecotextura homogênea em toda sua extensão. Os rins mostraram formato elipsóide, com cápsula fina, regular e hiperecóica. Os folículos ovarianos apresentaram formato ovóide, margens finas, regulares e discretamente hiperecóicas. As estruturas do sistema reprodutor do macho não foram evidenciadas com precisão, devido a sua ecogenicidade similar em relação às estruturas adjacentes e pela presença do "corpo gorduroso" localizado nessa região. A ultra-sonografia da cavidade celomática em jibóias demonstrou ser uma técnica rápida e de fácil acesso, permitindo identificar a morfologia, sintopia e aparência ultra-sonográfica de estruturas como o fígado, rins e de folículos vitelogênicos nas fêmeas.Currently, wild animals have been received special attention for domestic breeding. In Wild Animal Medicine, ultrasonographic exams could be considered as a tool to diagnose and prevent disease. Ultrasonographic examination of twenty snakes (Boa constrictor was performed in order to describe the morphological and ultrasonography appearance of their coelomic structures. Examination by ultrasonography revealed the parechymal liver ranging from slightly hypoechogenic to hyperechogenic, with echogenic margins and homogeneous echotexture in total scanning of this organ. The kidney was accessible for examination by sagittal ultrasound, showing an ellipsoid shape, a hyperechogenic capsule

  6. Ultrasonography of Neonatal Cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Jung Eun [Seoul National University Hospital, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography (US) is as an important tool for differentiation of obstructive and non-obstructive causes of jaundice in infants and children. Beyond two weeks of age, extrahepatic biliary atresia and neonatal hepatitis are the two most common causes of persistent neonatal jaundice: differentiation of extrahepatic biliary atresia, which requires early surgical intervention, is very important. Meticulous analysis should focus on size and configuration of the gallbladder and anatomical changes of the portahepatis. In order to narrow the differential diagnosis, combined approaches using hepatic scintigraphy, MR cholangiography, and, at times, percutaneous liver biopsy are necessary. US is useful for demonstrating choledochal cyst, bile plug syndrome, and spontaneous perforation of the extrahepatic bile duct

  7. Clinical characteristics of patients with diabetes mellitus and fatty liver diagnosed by liver/spleen Hounsfield units on CT scan

    OpenAIRE

    Sakitani, Kosuke; Enooku, Kenichiro; Kubo, Hirokazu; Tanaka, Akifumi; Arai, Hisakatsu; Kawazu, Shoji; Koike, Kazuhiko

    2017-01-01

    Objective The leading cause of liver injuries in diabetes mellitus may be associated with fatty liver. We aimed to elucidate the relationship between fatty liver and diabetes characteristics. Methods Retrospectively, 970 patients with diabetes were analysed. Fatty liver was diagnosed when the liver/spleen Hounsfield unit ratio by computed tomography was below 0.9. Clinical diabetes characteristics were compared between patients with and without fatty liver. Results Of 970 patients (717 male a...

  8. Accidental Radiogold ({sup 198}Au) Liver Scan Overdose with Fatal Outcome

    Energy Technology Data Exchange (ETDEWEB)

    Baron, J. M.; Yachnin, S.; Polcyn, R.; Fitch, F. W.; Sturner, W. Q. [Pritzker School of Medicine of the University of Chicago and Argonne Cancer Research Hospital (operated by the University of Chicago for the United States Atomic Energy Commission), Chicago, IL (United States)

    1969-10-15

    The first reported instance of accidental overdosage with intravenously administered radioactive colloidal gold ({sup 198}Au) given for liver scanning is described. A 73-year-old female with erythremic myelosis accompanied by hepatosplenomegaly received 200 millicuries instead of the intended dose of 200 microcuties. She was transferred to the Argonne Cancer Research Hospital at the University of Chicago the following day. External monitoring on the second day showed 35 mR/h at 1 metre. Total body scanning of the patient without administration of additional isotope revealed high activity and an abnormally extensive reticuloendothelial uptake. Blood activity at that time was 0.04 microcuries per millilitre of whole blood. Estimated radiation dosage to be received by the bone marrow was 400-500 Rand by the liver was 7000-8000 R. There were no symptoms of acute radiation exposure. The patient was placed in strict isolation on the fifth day, and surgical scrub precautions were continued until day 63. Supportive care included buffy . coat and platelet packs, prophylactic sterilization of the gastrointestinal tract, and, later, androgen and corticosteroids. The expected decrease in peripheral blood lymphocytes, granulocytes, and platelets occurred in the order mentioned. Liver size decreased, but function tests did not deteriorate. There was no difficulty with clinical infection during the granulocytopenic phase. Lymphocytes and, later, granulocytes showed recovery to subnormal levels, but platelets failed to rise above 8000/mm{sup 3} after the 21st day. The patient developed haematuria and purpura, and suffered a terminal spontaneous intracerebral haemorrhage on the 69th day. At post mortem there was evidence for patchy areas of granulocytic and erythroid marrow regeneration, and some extramedullary sites contained isolated clones of young red cell precursors. There were no specific changes in the liver. The lack of effective methods to mobilize or metabolize colloidal

  9. Improved detection and biopsy of solid liver lesions using pulse-inversion ultrasound scanning and contrast agent infusion

    DEFF Research Database (Denmark)

    Skjoldbye, B.; Pedersen, Morten Høgholm; Struckmann, J.

    2002-01-01

    The purpose of this study was to assess the ability of pulse-inversion ultrasound (US) scanning (PIUS), combined with an IV contrast agent, to detect malignant liver lesions and its impact on patient management (resectability). Additionally, to determine the feasibility of US-guided biopsy of new...... PIUS-findings at the same session. A total of 30 patients with known or clinically suspected cancer underwent conventional B-mode scanning and PIUS with IV-administered contrast agent. The number of liver metastases in the right and the left liver lobe, respectively, was recorded. All patients...... findings were performed in 17 of 18 patients. All biopsies of additional findings confirmed malignancy. PIUS with an IV contrast agent increased the ability to detect liver metastases compared to conventional US scanning. The technique had a high impact on patient management. The results showed that PIUS...

  10. [Pancreatic ultrasonography].

    Science.gov (United States)

    Fernández-Rodríguez, T; Segura-Grau, A; Rodríguez-Lorenzo, A; Segura-Cabral, J M

    2015-04-01

    Despite the recent technological advances in imaging, abdominal ultrasonography continues to be the first diagnostic test indicated in patients with a suspicion of pancreatic disease, due to its safety, accessibility and low cost. It is an essential technique in the study of inflammatory processes, since it not only assesses changes in pancreatic parenchyma, but also gives an indication of the origin (bile or alcoholic). It is also essential in the detection and tracing of possible complications as well as being used as a guide in diagnostic and therapeutic punctures. It is also the first technique used in the study of pancreatic tumors, detecting them with a sensitivity of around 70% and a specificity of 90%. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  11. Clinical characteristics of patients with diabetes mellitus and fatty liver diagnosed by liver/spleen Hounsfield units on CT scan.

    Science.gov (United States)

    Sakitani, Kosuke; Enooku, Kenichiro; Kubo, Hirokazu; Tanaka, Akifumi; Arai, Hisakatsu; Kawazu, Shoji; Koike, Kazuhiko

    2017-06-01

    Objective The leading cause of liver injuries in diabetes mellitus may be associated with fatty liver. We aimed to elucidate the relationship between fatty liver and diabetes characteristics. Methods Retrospectively, 970 patients with diabetes were analysed. Fatty liver was diagnosed when the liver/spleen Hounsfield unit ratio by computed tomography was below 0.9. Clinical diabetes characteristics were compared between patients with and without fatty liver. Results Of 970 patients (717 male and 253 female; mean age 64.4 years), 175 males (24.4%) and 60 females (23.7%) had fatty liver. None of the 28 patients with type 1 diabetes had fatty liver. In male patients with type 2 diabetes, age, visceral adipose tissue (VAT), albumin, alanine amino-transferase (ALT), and triglycerides were independently associated with fatty liver. In females, age and bilirubin were associated with fatty liver. Conclusions Fatty liver is associated with type 2 diabetes characteristics, including younger age and elevated VAT, albumin, ALT, and triglycerides in males and younger age and elevated bilirubin levels in females.

  12. Clinical characteristics of patients with diabetes mellitus and fatty liver diagnosed by liver/spleen Hounsfield units on CT scan

    Science.gov (United States)

    Sakitani, Kosuke; Enooku, Kenichiro; Kubo, Hirokazu; Tanaka, Akifumi; Arai, Hisakatsu; Kawazu, Shoji; Koike, Kazuhiko

    2017-01-01

    Objective The leading cause of liver injuries in diabetes mellitus may be associated with fatty liver. We aimed to elucidate the relationship between fatty liver and diabetes characteristics. Methods Retrospectively, 970 patients with diabetes were analysed. Fatty liver was diagnosed when the liver/spleen Hounsfield unit ratio by computed tomography was below 0.9. Clinical diabetes characteristics were compared between patients with and without fatty liver. Results Of 970 patients (717 male and 253 female; mean age 64.4 years), 175 males (24.4%) and 60 females (23.7%) had fatty liver. None of the 28 patients with type 1 diabetes had fatty liver. In male patients with type 2 diabetes, age, visceral adipose tissue (VAT), albumin, alanine amino-transferase (ALT), and triglycerides were independently associated with fatty liver. In females, age and bilirubin were associated with fatty liver. Conclusions Fatty liver is associated with type 2 diabetes characteristics, including younger age and elevated VAT, albumin, ALT, and triglycerides in males and younger age and elevated bilirubin levels in females. PMID:28553763

  13. Transvaginal ultrasonography of rectal endometriosis

    DEFF Research Database (Denmark)

    Egekvist, Anne Gisselmann; Seyer-Hansen, Mikkel; Forman, Axel

    Objectives: The aim of this present study was to evaluate the interobserver variation of transvaginal ultrasonographic measurements of endometriosis infiltrating the rectosigmoid wall. Methods: Transvaginal ultrasonography was performed independently by two observers. Observer 1 had several years...... of experience in ultrasonography while observer 2 was a medical student with no prior experience in ultrasonography or endometriosis. In 24 patient length, width and depth of endometriosis infiltrating the rectosigmoid bowel was measured. The differences between the observers were analysed by Bland and Altman...... for a relatively short period gives comparable scanning results between the two observers. It seems that transvaginal ultrasound could be used as a diagnostic tool for rectal endometriosis in most departments. However, the irregular morphology of the lesions makes the measurements very complex, and a strict...

  14. Abdominal ultrasonography, 2nd Ed

    International Nuclear Information System (INIS)

    Goldberg, B.B.

    1984-01-01

    This volume is a new and updated edition of an extensively illustrated text and reference on the capabilities and imaging of gray scale ultrasonography for each major abdominal organ. Each major organ system is treated separately, including liver, gallbladder and bile ducts, pancreas, kidney, retroperitoneum, abdominal vasculature, and more. There are over 500 illustrations and ten pages of full color plates for cross sectional anatomy

  15. Comparison between coupled KZK-BHTE numerical simulations and scanned HIFU exposures in excised bovine liver

    Science.gov (United States)

    Andrew, Marilee A.; Brayman, Andrew A.; Kaczkowski, Peter J.; Kargl, Steven G.

    2004-05-01

    The use of moving high intensity focused ultrasound (HIFU) treatment protocols is of interest in achieving efficient formation of large-volume lesions in tissue. However, potentially unwanted thermal effects, such as prefocal heating, should be considered. A KZK acoustic model coupled with the BioHeat Transfer Equation has been extended to simulate multiple, moving scans in tissue. Simulation results are compared with experimental data collected over a range of exposure regimes for linear and concentric circular scans with a 3.5-MHz single-element transducer in ex vivo bovine liver. Of particular interest are investigating prefocal thermal buildup and ablating the central core of a circular pattern through conductive heating, that is without direct HIFU exposure. Qualitative agreement is observed between experimental and simulated data; limits of the predictive capability of the model in cavitation regimes will be discussed. [Support provided by the U.S. Army Medical Research Acquisition Activity through The University of Mississippi under terms of Agreement No. DAMD17-02-2-0014. The opinions expressed herein are those of the author(s) and do not necessarily reflect the views of U.S. Army Medical Research Acquisition Activity or The University of Mississippi.

  16. Improved image quality and radiation dose reduction in liver dynamic CT scan with the protocol change

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yu Jin; Cho, Pyong Kon [Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2015-06-15

    The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5-24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120 kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100 kVp, apply SAFIRE strength 0-5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120 kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100 kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100 kVp than 120 kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality

  17. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  18. A review of the benefits and rationale of viewing liver window settings for abdominal computed tomography scans

    International Nuclear Information System (INIS)

    Dang, Tan; Mandarano, Giovanni

    2006-01-01

    There have been many different opinions over the efficacy of routinely incorporating liver-window settings in abdominal computed tomography (CT) scans. As a result, different clinical centres have varying protocols for incorporating liver-windows for abdominal CT scans. This investigation aims to explore and determine whether various clinical centres throughout Victoria use liver-window settings selectively or routinely and their justification for doing so. An additional purpose is also to assess the benefits and rationale of liver-window settings in supplementing routine soft-tissue-windows for abdominal CT examinations by reviewing evidenced-based studies. Surveys were sent out to CT supervisors at various clinical centres, including private and public institutions. This achieved an overall response rate of 74 per cent. Results indicate that the majority of clinical centres throughout Victoria routinely incorporate liver-window settings for all abdominal CT examinations. Forty four per cent (11/25) of respondents stated that they utilise liver-window settings selectively for abdominal CT examinations. Most of these respondents (7/11 = 63 per cent) believed that soft-tissue-window settings alone are adequate to demonstrate hepatic lesions; particularly if intravenous contrast media is used and the liver is captured in the arterial, venous and/or delayed phases. The benefits and rationale of incorporating liver-window settings for all abdominal computed tomography scans has been questioned by two well noted studies in the United States. These evidence-based studies suggest that such additional settings do not offer further advantages in detecting hepatic disease, when compared to soft-tissue-windows alone. Review of the available literature provides additional evidence suggesting that the routine use of liver-window settings in conjunction with soft-tissue-windows offers no further advantages in the detection of hepatic diseases. This investigation found, however

  19. Hepatobiliary ultrasonography

    Science.gov (United States)

    Sembiring, J.

    2018-03-01

    Ultrasound is one of the most widely used imaging technologies in medicine. It is portable, free of radiation risk, non-invasive and relatively inexpensive when compared with other imaging modalities, such as magnetic resonance and computed tomography. Ultrasound is a useful procedure for evaluating many structures organ in our body. An examination may include the entirety of the abdomen and retroperitoneum from a single organ to several organs. An abdominal ultrasound examination survey would include the liver, gallbladder, biliary tree, pancreas, spleen, kidneys and retroperitoneal structures. It needsperforming when there is a valid medical reason.

  20. Unusual biliary scan appearance in a child with a transplanted liver with hepatic arterial thrombosis: a case report.

    Science.gov (United States)

    Porn, U; Howman-Giles, R; Shun, A; Dorney, S; Uren, R

    2000-02-01

    A 5-year-old girl with biliary atresia and a subsequent Kasai procedure is described. She had clinical symptoms suggestive of rejection after a recent orthotopic liver transplant A hepatobiliary scan showed partial hepatic infarction and a biloma in the infarcted area.

  1. The spleen-liver uptake ratio in liver scan: review of its measurement and correlation between hemodynamical changes of the liver in portal hypertension

    International Nuclear Information System (INIS)

    Lee, S. Y.; Chung, Y. A.; Chung, H. S.; Lee, H. G.; Kim, S. H.; Chung, S. K.

    1999-01-01

    We analyzed correlation between changes of the Spleen-Liver Ratio in liver scintigram and hemodynamical changes of the liver in overall grades of portal hypertension by non-invasive, scintigraphic method. And the methods for measurement of the Spleen-Liver Ratio were also reviewed. Hepatic scintiangiograms for 120 seconds with 250-333 MBq of 99mTc-Sn-phytate followed by liver scintigrams were performed in 62 patients group consisted with clinically proven norma and various diffuse hepatocellular diseases. Hepatic Perfusion indices were calculated from the Time-Activity Curves of hepatic scintiangiograms. Each Spleen-Liver Ratios of maximum, average and total counts within ROIs of the liver and spleen from both anterior and posterior liver scintigrams and their geometrical means were calculated. Linear correlations between each Spleen-Liver Ratios and Hepatic Perfusion indices were evaluated. There was strong correlation (y=0.0002x 2 -0.0049x+0.2746, R=0.8790, p<0.0001) between Hepatic Perfusion Indices and Spleen-Liver Ratios calculated from posterior maxium counts of the liver scintigrams. Weaker correlations with either geometrical means of maximum and average count methods (R=0.8101, 0.7268, p<0.0001) or average counts of both posterior and anterior veiws (R=0.8134, 0.6200, p<0.0001) were noted. We reconfirmed that changes of Spleen-Liver Ratio in liver scintigrams represent hemodynamical changes in portal hypertension of diffuse hepatocellular diseases. Among them, the posterior Spleen-Liver Ratio measured by maximum counts will give the best information. And matching with Hepatic Perfusion index will be another useful index to evaluate characteristics splenic extraction coefficient of a certain radiocolloid for liver scintigram

  2. Diagnostic accuracy and prognostic significance of blood fibrosis tests and liver stiffness measurement by FibroScan in non-alcoholic fatty liver disease.

    Science.gov (United States)

    Boursier, Jérôme; Vergniol, Julien; Guillet, Anne; Hiriart, Jean-Baptiste; Lannes, Adrien; Le Bail, Brigitte; Michalak, Sophie; Chermak, Faiza; Bertrais, Sandrine; Foucher, Juliette; Oberti, Frédéric; Charbonnier, Maude; Fouchard-Hubert, Isabelle; Rousselet, Marie-Christine; Calès, Paul; de Lédinghen, Victor

    2016-09-01

    NAFLD is highly prevalent but only a small subset of patients develop advanced liver fibrosis with impaired liver-related prognosis. We aimed to compare blood fibrosis tests and liver stiffness measurement (LSM) by FibroScan for the diagnosis of liver fibrosis and the evaluation of prognosis in NAFLD. Diagnostic accuracy was evaluated in a cross-sectional study including 452 NAFLD patients with liver biopsy (NASH-CRN fibrosis stage), LSM, and eight blood fibrosis tests (BARD, NAFLD fibrosis score, FibroMeter(NAFLD), aspartate aminotransferase to platelet ratio index (APRI), FIB4, FibroTest, Hepascore, FibroMeter(V2G)). Prognostic accuracy was evaluated in a longitudinal study including 360 NAFLD patients. LSM and FibroMeter(V2G) were the two best-performing tests in the cross-sectional study: AUROCs for advanced fibrosis (F3/4) were, respectively, 0.831±0.019 and 0.817±0.020 (p⩽0.041 vs. other tests); rates of patients with ⩾90% negative/positive predictive values for F3/4 were 56.4% and 46.7% (ptests); Obuchowski indexes were 0.834±0.014 and 0.798±0.016 (p⩽0.036 vs. other tests). Two fibrosis classifications were developed to precisely estimate the histological fibrosis stage from LSM or FibroMeter(V2G) results without liver biopsy (diagnostic accuracy, respectively: 80.8% vs. 77.4%, p=0.190). Kaplan-Meier curves in the longitudinal study showed that both classifications categorised NAFLD patients into subgroups with significantly different prognoses (pfibrosis classification, the worse was the prognosis. LSM and FibroMeter(V2G) were the most accurate of nine evaluated tests for the non-invasive diagnosis of liver fibrosis in NAFLD. LSM and FibroMeter(V2G) fibrosis classifications help physicians estimate both fibrosis stage and patient prognosis in clinical practice. The amount of liver fibrosis is the main determinant of the liver-related prognosis in patients with non-alcoholic fatty liver disease (NAFLD). We evaluated eight blood tests and FibroScan

  3. Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    Science.gov (United States)

    Boas, F Edward; Kamaya, Aya; Do, Bao; Desser, Terry S; Beaulieu, Christopher F; Vasanawala, Shreyas S; Hwang, Gloria L; Sze, Daniel Y

    2015-04-01

    Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver lesions. Triphasic CTs of 46 malignant and 32 benign liver lesions were analyzed. For each phase, regions of interest were drawn in the arterially enhancing portion of each lesion, as well as the background liver, aorta, and portal vein. Hepatic artery and portal vein blood supply coefficients for each lesion were then calculated by expressing the enhancement curve of the lesion as a linear combination of the enhancement curves of the aorta and portal vein. Hepatocellular carcinoma (HCC) and hypervascular metastases, on average, both had increased hepatic artery coefficients compared to the background liver. Compared to HCC, benign lesions, on average, had either a greater hepatic artery coefficient (hemangioma) or a greater portal vein coefficient (focal nodular hyperplasia or transient hepatic attenuation difference). Hypervascularity with washout is a key diagnostic criterion for HCC, but it had a sensitivity of 72 % and specificity of 81 % for diagnosing malignancy in our diverse set of liver lesions. The sensitivity for malignancy was increased to 89 % by including enhancing lesions that were hypodense on all phases. The specificity for malignancy was increased to 97 % (p = 0.039) by also examining hepatic artery and portal vein blood supply coefficients, while maintaining a sensitivity of 76 %.

  4. An analysis of 1018 cases of ultrasonography

    International Nuclear Information System (INIS)

    Kim, Chu Wan; Suh, Jeong Soo; Lee, Kwan Seh; Kim, Ki Hwan; Im, Chung Gie; Chang, Kee Hyun; Yeon, Kyung Mo; Han, Man Chung; Choo, Dong Woon

    1985-01-01

    Ultrasound is an especially helpful diagnostic tool in assessing various diseases in various organs as well as differentiating cystic masses from solid ones, with ease safety, reproducibility, and high accuracy. Authors analyzed total 1018 cases of ultrasonography that were studied in last seven months from March. 15. 1979 to October. 31. 1979, at the Department of Radiology, Seoul National University Hospital. The results were as follows: 1. Among the 1018 cases, 421 cases were male and 597 cases of female. The age distribution was from several months to 83 years, and 88% of all cases were in 20 to 69 years of age. 2. Sites of scanning; Liver, G.B. and biliary systems 376, thyroid 185, kidney 192, pelvis 121, abdomen 70, pancreas 48, eyeball 14, and other 12. 3. Hepatobiliary system 376; Normal 174, hepatomegaly 12, hepatoma 7, metastases 6, abscess 6, cirrhosis 2, hepatic cyst 1, hemangioma 1, agenesis of left lobe 1. 4. G.B. stones 106, cholecystitis 35, biliary tree dilatation 13, enlarged G.B. 7, C.B.D. stone 5, cystic duct stone 4, C.B.D. cancer 6, G.B. cancer 1, choledochal cyst 1, non-visualized G.B. 8. 5. Thyroid, 185; Nodule 147 -- solid 56, cystic 70, complex 21, Diffuse enlargement 29, normal scan 7, unidentified 2. 6. Pancreas, 48; Normal 17, pancreastitis 4, pancreatic cancer 22, pseudocyst 4, unidentified 1. 7. Abdomen 77 (excluding liver, G.B. and pancreas); Normal scan 31, solid tumor 14 - lymphoma group 12, mesenchyma origin 2, multiple lymph node enlargement 13, aortic aneurysm 4, retroperitoneal mass 2, subphrenic abscess 2, abdominal wall abscess 2, unknown solid mass 4, not contributory 4. 8. Kidney, 194, Normal scan 44, size and markings for biopsy 75, hydronephrosis 21, renal cyst 8, polycystic disease 8, solid renal tumor 10, renal stone 7, agenesis or hypoplasia 2, contracted kidney, both 7, enlarge kidney due to lymphoma and compensatory hyperplasia 5, renal tbc 2, perirenal abscess 1, perirenal hematoma 1, movable kidney 1, bladder tumor

  5. WE-E-BRB-02: Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patient

    International Nuclear Information System (INIS)

    Lin, L.

    2016-01-01

    Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and

  6. WE-E-BRB-02: Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patient

    Energy Technology Data Exchange (ETDEWEB)

    Lin, L. [University of Pennsylvania (United States)

    2016-06-15

    Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and

  7. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  8. Automated measurement of uptake in cerebellum, liver, and aortic arch in full-body FDG PET/CT scans.

    Science.gov (United States)

    Bauer, Christian; Sun, Shanhui; Sun, Wenqing; Otis, Justin; Wallace, Audrey; Smith, Brian J; Sunderland, John J; Graham, Michael M; Sonka, Milan; Buatti, John M; Beichel, Reinhard R

    2012-06-01

    The purpose of this work was to develop and validate fully automated methods for uptake measurement of cerebellum, liver, and aortic arch in full-body PET/CT scans. Such measurements are of interest in the context of uptake normalization for quantitative assessment of metabolic activity and/or automated image quality control. Cerebellum, liver, and aortic arch regions were segmented with different automated approaches. Cerebella were segmented in PET volumes by means of a robust active shape model (ASM) based method. For liver segmentation, a largest possible hyperellipsoid was fitted to the liver in PET scans. The aortic arch was first segmented in CT images of a PET/CT scan by a tubular structure analysis approach, and the segmented result was then mapped to the corresponding PET scan. For each of the segmented structures, the average standardized uptake value (SUV) was calculated. To generate an independent reference standard for method validation, expert image analysts were asked to segment several cross sections of each of the three structures in 134 F-18 fluorodeoxyglucose (FDG) PET/CT scans. For each case, the true average SUV was estimated by utilizing statistical models and served as the independent reference standard. For automated aorta and liver SUV measurements, no statistically significant scale or shift differences were observed between automated results and the independent standard. In the case of the cerebellum, the scale and shift were not significantly different, if measured in the same cross sections that were utilized for generating the reference. In contrast, automated results were scaled 5% lower on average although not shifted, if FDG uptake was calculated from the whole segmented cerebellum volume. The estimated reduction in total SUV measurement error ranged between 54.7% and 99.2%, and the reduction was found to be statistically significant for cerebellum and aortic arch. With the proposed methods, the authors have demonstrated that

  9. Acute fatty liver of pregnancy. CT scan imaging in 4 cases

    International Nuclear Information System (INIS)

    Coche, G.; Moran, V.; Schmitt, M.; Boillot, A.; Miguet, J.P.; Hadni-Bresson, S.; Weill, F.S.

    1987-01-01

    Acute fatty liver of pregnancy is a disease of the third trimester, generally considered to be rare and to have a grave prognosis. Histologically the characteristic fine droplet steatosis usually produces distinct vacuolization. Successful treatment depends on accurate diagnosis and early delivery. Computed tomography is of value in the diagnosis of fatty liver through liver and spleen attenuation value measurements. We reviewed 4 cases of acute fatty liver of pregnancy. Computed tomography was performed in two cases and was very helpful in the diagnosis of this condition [fr

  10. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  11. A Case of with Transient splenic Hot Uptake on {sup 99m}Tc-Methylene Diphosphonate (MDP) Bone Scan Following Blunt Abodominal Trauma with Underlying Liver Cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Hyeon; Kim, Jae Myung; Kim, Jung Han; Choo, Gil Yeon; Park, Seok Oh; Sung, Sang Kyu; Choi, Dae Seob; Kim, Chin Seung [Sung Ae General Hospital, Seoul (Korea, Republic of)

    1993-07-15

    We report a case of 33-year-old man with a transient splenic uptake who had traumatic multiple rib fractures and hemoperitoneum combined with underlying liver cirrhosis, liver cirrhosis with liver bed laceration and splenomegaly without any other demonstrable splenic lesion due to traffic accident was found by abdominal ultrasound and surgery. Incidentally, {sup 99m}Tc-MDP Bone scan showed whole prominent splenic uptake, spleen was also visible on {sup 99m}Tc Tin colloid liver scan. We suggest the splenic uptake of the radionuclide temporary splenic infarct to the transient total splenic infarction or unknown traumatic effect.

  12. A Case of with Transient splenic Hot Uptake on 99mTc-Methylene Diphosphonate (MDP) Bone Scan Following Blunt Abodominal Trauma with Underlying Liver Cirrhosis

    International Nuclear Information System (INIS)

    Won, Jong Hyeon; Kim, Jae Myung; Kim, Jung Han; Choo, Gil Yeon; Park, Seok Oh; Sung, Sang Kyu; Choi, Dae Seob; Kim, Chin Seung

    1993-01-01

    We report a case of 33-year-old man with a transient splenic uptake who had traumatic multiple rib fractures and hemoperitoneum combined with underlying liver cirrhosis, liver cirrhosis with liver bed laceration and splenomegaly without any other demonstrable splenic lesion due to traffic accident was found by abdominal ultrasound and surgery. Incidentally, 99m Tc-MDP Bone scan showed whole prominent splenic uptake, spleen was also visible on 99m Tc Tin colloid liver scan. We suggest the splenic uptake of the radionuclide temporary splenic infarct to the transient total splenic infarction or unknown traumatic effect.

  13. Evaluation of liver parenchyma and perfusion using dynamic contrast-enhanced computed tomography and contrast-enhanced ultrasonography in captive green iguanas (Iguana iguana) under general anesthesia.

    Science.gov (United States)

    Nardini, Giordano; Di Girolamo, Nicola; Leopardi, Stefania; Paganelli, Irene; Zaghini, Anna; Origgi, Francesco C; Vignoli, Massimo

    2014-05-13

    Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

  14. Role of Ultrasonography in Acute Abdomen

    International Nuclear Information System (INIS)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee; Jung, Jae Un

    1996-01-01

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients under vent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4),peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1 ) and pelvic inflammatory disease (n = 1 ). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  15. Role of Ultrasonography in Acute Abdomen

    Energy Technology Data Exchange (ETDEWEB)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee [Dankook University College of Medicine, Cheonan (Korea, Republic of); Jung, Jae Un [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1996-12-15

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients underwent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4), peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1) and pelvic inflammatory disease (n = 1). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  16. [Technique of abdominal ultrasonography in newborn foals and normal findings].

    Science.gov (United States)

    Behn, C; Bostedt, H

    2000-09-01

    Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.

  17. Osseous and Nonosseous Bone Scan Findings in Liver Transplant Candidates with end-stage Chronic Liver Disease

    Directory of Open Access Journals (Sweden)

    Seval Erhamamcı

    2013-08-01

    Full Text Available Objective: End-stage chronic liver disease (CLD adversely affects the function of multiple organ systems including the skeletal system. The aim of this study was to assess osseous and nonosseous bone scintigraphy (BS findings in liver transplant (LT candidates with end-stage CLD. Methods: We retrospectively evaluated BS findings in 50 consecutive patients with end-stage CLD who were undergoing preoperative assessment for LT from January 2006 to December 2011. All the patients were analyzed with respect to clinical and laboratory parameters, and BS findings. Scintigrams were visually assessed for the presence of osseous and nonosseous abnormalities. Osseous abnormalities were classified as those indicating bone metabolism changes or metastatic bone disease. Typical scintigraphic findings denoting to changes in bone metabolism were the presence of decreased osseous uptake, increased periarticular uptake, asymmetrical or unusual uptake patterns. Nonosseous findings were classified according to the degree of soft-tissue uptake as mild and severe. Results: The group consisted of 46 adult and 4 adolescent patients. All adolescent patients had normal skeletal accumulation with growth plate uptake and one had mildly increased renal cortical activity. A total of 46 adult patients had one or more of the following osseous findings: generalized decrease in osseous uptake (n=4, 8.7%; bilateral decrease in lower extremity uptake (n=26, 56.5%; symmetrically increased periarticular uptake (n=26, 56.5%; bilateral cortical/periosteal increased uptake in the lower extremity indicating hepatic hypertrophic osteoarthropathy (HOA (n=8, 17.4%; bilateral increased sacroiliac activity (n=16, 34.8%; sacral activity (n=10, 21.7%, coccygeal activity (n=2, 4.3%, focally increased uptake suggestive of metastases (n=5, 10.9%. Three rib metastases appeared to be linear. Nonosseous findings observed in adult patients were mild diffuse liver uptake (n=4, 8.7% and bilateral

  18. Tissue ablation accelerated by peripheral scanning mode with high-intensity focused ultrasound: a study on isolated porcine liver perfusion.

    Science.gov (United States)

    Bu, Rui; Yin, Li; Yang, Han; Wang, Qi; Wu, Feng; Zou, Jian Zhong

    2013-08-01

    The aims of this study were to investigate the feasibility of accelerated tissue ablation using a peripheral scanning mode with high-intensity focused ultrasound (HIFU) and to explore the effect of flow rate on total energy consumption of the target tissues. Using a model of isolated porcine liver perfusion via the portal vein and hepatic artery, we conducted a scanning protocol along the periphery of the target tissues using linear-scanned HIFU to carefully adjust the varying focal depth, generator power, scanning velocity and line-by-line interval over the entire ablation range. Porcine livers were divided into four ablation groups: group 1, n = 12, with dual-vessel perfusion; group 2, n = 11, with portal vein perfusion alone; group 3, n = 10, with hepatic artery perfusion alone; and group 4, n = 11, control group with no-flow perfusion. The samples were cut open consecutively at a thickness of 3 mm, and the actual ablation ranges were calculated along the periphery of the target tissues after triphenyl tetrazolium chloride staining. Total energy consumption was calculated as the sum of the energy requirements at various focal depths in each group. On the basis of the pre-supposed scanning protocol, the peripheral region of the target tissue formed a complete coagulation necrosis barrier in each group with varying dose combinations, and the volume of the peripheral necrotic area did not differ significantly among the four groups (p > 0.05). Furthermore, total energy consumption in each group significantly decreased with the corresponding decrease in flow rate (p Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  20. Radiation absorbed-dose estimates for the liver, spleen, and metaphyseal growth complexes in children undergoing gallium-67 citrate scanning

    International Nuclear Information System (INIS)

    Thomas, S.R.; Gelfand, M.J.; Burns, G.S.; Purdom, R.C.; Kereiakes, J.G.; Maxon, H.R.

    1983-01-01

    Quantitative conjugate-view external counting techniques were applied to estimate the radiation dose to the liver, spleen, and metaphyseal growth complexes (distal femur and proximal tibia) for ten pediatric patients undergoing gallium-67 scanning procedures. The effective half-life of Ga 67 in these organs was approximately 78 hours. The dose per unit of administered activity for the liver and spleen was between 0.3 and 4.0 rad/mCi (0.08 to 1.08 Gy/GBq) and 0.5 and 7.0 rad/mCi (0.13 to 1.89 Gy/GBq), respectively. For the metaphyseal growth plates, the range was 2.3 to 14.3 rad/mCi (0.62 to 3.86 Gy/GBq)

  1. Quantification of Hepatorenal Index for Computer-Aided Fatty Liver Classification with Self-Organizing Map and Fuzzy Stretching from Ultrasonography

    Directory of Open Access Journals (Sweden)

    Kwang Baek Kim

    2015-01-01

    Full Text Available Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future.

  2. Has the liver and other visceral organs migrated to its normal position in children with giant omphalocele? A follow-up study with ultrasonography

    NARCIS (Netherlands)

    F.C. van Eijck (Floortje); W.M. Klein (Willemijn); C. Boetes (Carla); D.C. Aronson (Daniel); R.M.H. Wijnen (René)

    2010-01-01

    textabstractThis study evaluates whether, on the long run, in patients born with a giant omphalocele, the liver and other solid organs reach their normal position, shape, and size. Seventeen former patients with a giant omphalocele, treated between 1970 and 2004, were included. Physical examination

  3. Has the liver and other visceral organs migrated to its normal position in children with giant omphalocele? A follow-up study with ultrasonography

    NARCIS (Netherlands)

    van Eijck, Floortje Clemens; Klein, Willemijn M.; Boetes, Carla; Aronson, Daniel C.; Wijnen, Rene M. H.

    2010-01-01

    This study evaluates whether, on the long run, in patients born with a giant omphalocele, the liver and other solid organs reach their normal position, shape, and size. Seventeen former patients with a giant omphalocele, treated between 1970 and 2004, were included. Physical examination was

  4. Has the liver and other visceral organs migrated to its normal position in children with giant omphalocele? A follow-up study with ultrasonography.

    NARCIS (Netherlands)

    Eijck, F.C. van; Klein, W.M.; Hitge-Boetes, C.; Aronson, D.C.; Wijnen, R.M.H.

    2010-01-01

    This study evaluates whether, on the long run, in patients born with a giant omphalocele, the liver and other solid organs reach their normal position, shape, and size. Seventeen former patients with a giant omphalocele, treated between 1970 and 2004, were included. Physical examination was

  5. Stabilized alcohol solution of reducing salt formulations for use in preparing radioisotope labelled scanning agents: liver scanning technetium-99m colloid and method of preparation

    International Nuclear Information System (INIS)

    1980-01-01

    The preparation of a radiolabelled scanning agent for imaging reticuloendothelial organs, including the liver and spleen, is described. It consists of a sup(99m)Tc labelled colloid of a metal ion salt reductant, such as SnCl 2 , TiCl 3 , CrCl 2 or FeCl 2 , and an anhydrous non-oxidising organic solvent, such as diethyl ether, ethanol or another aliphatic alcohol. Examples are given of the effects of varying the pH, the metal ion salt reductant concentration, the eluate and solvent volumes and the temperature of the radiopharmaceutical on the tagging efficiency and organ distribution in mice and rabbits. (U.K.)

  6. Quantitative muscle ultrasonography in amyotrophic lateral sclerosis.

    NARCIS (Netherlands)

    Arts, I.M.P.; Rooij, F.G. van; Overeem, S.; Pillen, S.; Janssen, H.M.; Schelhaas, H.J.; Zwarts, M.J.

    2008-01-01

    In this study, we examined whether quantitative muscle ultrasonography can detect structural muscle changes in early-stage amyotrophic lateral sclerosis (ALS). Bilateral transverse scans were made of five muscles or muscle groups (sternocleidomastoid, biceps brachii/brachialis, forearm flexor group,

  7. False-positive liver scans due to portal hypertension: correlation with percutaneous transhepatic portograms in 33 patients

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Suzuki, M.; Yamada, T.; Fukutake, T.; Shima, Y.; Kobayashi, C.; Musha, H.; Okuda, K.

    1983-01-01

    Tc-99m-phytate scanning of the liver and percutaneous transhepatic catheterization of the portal vein were performed in 33 patients--26 with cirrhosis, 3 with chronic active hepatitis, 2 with idiopathic portal hypertension, and 2 with unresolved acute hepatitis. A discrete defect in the porta hepatis area was seen in 6 of 28 patients who had portal vein pressure above 200 mm H2O. In 5 of the 6 patients with a false-positive scan, the umbilical portion of the left portal vein branch was dilated (larger than 25 x 20 mm) on the portogram, with or without a patent paraumbilical vein. The anatomical basis of this phenomenon is discussed, and it is suggested that this area be given special attention

  8. CT scans in studies of the dynamics of liposynthesis and lipolysis of the human liver

    International Nuclear Information System (INIS)

    Huebener, K.H.; Schmitt, W.G.H.

    1981-01-01

    Following an analysis of the most important metabolic disturbances and other diseases associated ith fatty degeneration of the liver, it is shown, basing on a previous study, by means of examples, that subtle diagnosis of changes of the fatty content of the liver can be achieved via CT density measurement. Lipolysis in alcoholic fatty liver is quantified during abstention from alcohol, and a lipolysis factor of 1% fatty decomposition per day is determined from the measurements. Observations in pancreatitis with liver lipid storage during the course of the disease, point to an enzymatic weakness in lipid metabolism. Case histories show fatty degeneration associated with an enhanced cortisone serum level (in adrenal adenoma and cortisone therapy) and in poorly stabilized diabetes mellitus. It is concluded from the studies that determination of the relative fatty content by CT densitometry should be conducted as a routine procedure and that pathological lipid content should stimulate subtle diagnosis of the pancreas and the adrenals. In addition, examinations repeated during the course of the disease with assessment of changes in fatty content, will be useful for assessing the value of the therapy employed. (orig.) [de

  9. Liver metastases of breast carcinoma detected on /sup 99m/Tc-methylene diphosphonate bone scan

    International Nuclear Information System (INIS)

    Baumert, J.E.; Lantieri, R.L.; Horning, S.; McDougall, I.R.

    1980-01-01

    The accumulation of bone-seeking radiopharmaceuticals has been reported in liver metastases from colon carcinoma and oat cell carcinoma of the lung. Two patients with breast carcinoma in whom hepatic metastases were visualized on /sup 99m/Tc-methylene diphosphonate bone images are described. This has not been previously reported

  10. CT scans in studies of the dynamics of liposynthesis and lipolysis of the human liver

    Energy Technology Data Exchange (ETDEWEB)

    Huebener, K H; Schmitt, W G.H.

    1981-06-01

    Following an analysis of the most important metabolic disturbances and other diseases associated with fatty degeneration of the liver, it is shown, basing on a previous study, by means of examples, that subtle diagnosis of changes of the fatty content of the liver can be achieved via CT density measurement. Lipolysis in alcoholic fatty liver is quantified during abstention from alcohol, and a lipolysis factor of 1% fatty decomposition per day is determined from the measurements. Observations in pancreatitis with liver lipid storage during the course of the disease, point to an enzymatic weakness in lipid metabolism. Case histories show fatty degeneration associated with an enhanced cortisone serum level (in adrenal adenoma and cortisone therapy) and in poorly stabilized diabetes mellitus. It is concluded from the studies that determination of the relative fatty content by CT densitometry should be conducted as a routine procedure and that pathological lipid content should stimulate subtle diagnosis of the pancreas and the adrenals. In addition, examinations repeated during the course of the disease with assessment of changes in fatty content, will be useful for assessing the value of the therapy employed.

  11. A fully automatic end-to-end method for content-based image retrieval of CT scans with similar liver lesion annotations.

    Science.gov (United States)

    Spanier, A B; Caplan, N; Sosna, J; Acar, B; Joskowicz, L

    2018-01-01

    The goal of medical content-based image retrieval (M-CBIR) is to assist radiologists in the decision-making process by retrieving medical cases similar to a given image. One of the key interests of radiologists is lesions and their annotations, since the patient treatment depends on the lesion diagnosis. Therefore, a key feature of M-CBIR systems is the retrieval of scans with the most similar lesion annotations. To be of value, M-CBIR systems should be fully automatic to handle large case databases. We present a fully automatic end-to-end method for the retrieval of CT scans with similar liver lesion annotations. The input is a database of abdominal CT scans labeled with liver lesions, a query CT scan, and optionally one radiologist-specified lesion annotation of interest. The output is an ordered list of the database CT scans with the most similar liver lesion annotations. The method starts by automatically segmenting the liver in the scan. It then extracts a histogram-based features vector from the segmented region, learns the features' relative importance, and ranks the database scans according to the relative importance measure. The main advantages of our method are that it fully automates the end-to-end querying process, that it uses simple and efficient techniques that are scalable to large datasets, and that it produces quality retrieval results using an unannotated CT scan. Our experimental results on 9 CT queries on a dataset of 41 volumetric CT scans from the 2014 Image CLEF Liver Annotation Task yield an average retrieval accuracy (Normalized Discounted Cumulative Gain index) of 0.77 and 0.84 without/with annotation, respectively. Fully automatic end-to-end retrieval of similar cases based on image information alone, rather that on disease diagnosis, may help radiologists to better diagnose liver lesions.

  12. Ultrasonography and surgery of canine biliary diseases.

    Science.gov (United States)

    Vörös, K; Németh, T; Vrabély, T; Manczur, F; Tóth, J; Magdus, M; Perge, E

    2001-01-01

    Findings of hepatic and gallbladder ultrasonography were analyzed in 12 dogs with gallbladder and/or extrahepatic biliary tract obstruction and compared with the results of exploratory laparotomy. Hepatic ultrasonography demonstrated normal liver in 2 dogs and hepatic abnormalities in 10 animals. The following ultrasonographic diagnoses were established compared to surgical findings: gallbladder obstruction caused by bile sludge (correct/incorrect: 1/2, surgical diagnosis: choleliths in one case), gallbladder obstruction caused by neoplasm (0/1, surgical diagnosis: mucocele), gallbladder and extrahepatic biliary tract obstruction due to choleliths (3/3), extrahepatic biliary tract obstruction caused by pancreatic mass (1/1) and small intestinal volvulus (1/1). Bile peritonitis caused by gallbladder rupture (4/4) was correctly diagnosed by ultrasound, aided with ultrasonographically-guided abdominocentesis and peritoneal fluid analysis. Rupture of the gallbladder should be suspected in the presence of a small, echogenic gallbladder or in the absence of the organ together with free abdominal fluid during ultrasonography. Laparotomy was correctly indicated by ultrasonography in all cases. However, the direct cause of obstruction could not be determined in 2 of the 12 dogs by ultrasonography alone.

  13. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  14. [Comparison of the M and XL FibroScan(®) probes to estimate liver stiffness by transient elastography].

    Science.gov (United States)

    Herrero, José Ignacio; Iñarrairaegui, Mercedes; D'Avola, Delia; Sangro, Bruno; Prieto, Jesús; Quiroga, Jorge

    2014-04-01

    The FibroScan(®) XL probe has been specifically designed for obese patients to measure liver stiffness by transient elastography, but it has not been well tested in non-obese patients. The aim of this study was to compare the M and XL FibroScan(®) probes in a series of unselected obese (body mass index above 30 kg/m(2)) and non-obese patients with chronic liver disease. Two hundred and fifty-four patients underwent a transient elastography examination with both the M and XL probes. The results obtained with the two probes were compared in the whole series and in obese (n=82) and non-obese (n=167) patients separately. The reliability of the examinations was assessed using the criteria defined by Castéra et al. The proportion of reliable exams was significantly higher when the XL probe was used (83% versus 73%; P=.001). This significance was maintained in the group of obese patients (82% versus 55%; P<.001), but not in the non-obese patients (84% versus 83%). Despite a high correlation between the stiffness values obtained with the two probes (R=.897; P<.001), and a high concordance in the estimation of fibrosis obtained with the two probes (Cronbach's alpha value: 0.932), the liver stiffness values obtained with the XL probe were significantly lower than those obtained with the M probe, both in the whole series (9.5 ± 9.1 kPa versus 11.3 ± 12.6 kPa; P<0.001) and in the obese and non-obese groups. In conclusion, transient elastography with the XL probe allows a higher proportion of reliable examinations in obese patients but not in non-obese patients. Stiffness values were lower with the XL probe than with the M probe. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  15. CT Scanning in Identification of Sheep Cystic Echinococcosis.

    Science.gov (United States)

    Mao, Rui; Qi, Hongzhi; Pei, Lei; Hao, Jie; Dong, Jian; Jiang, Tao; Ainiwaer, Abudula; Shang, Ge; Xu, Lin; Shou, Xi; Zhang, Songan; Wu, Ge; Lu, Pengfei; Bao, Yongxing; Li, Haitao

    2017-01-01

    We aim to determine the efficiency of CT in identification of cystic echinococcosis in sheep. Fifty-three sheep with liver cysts confirmed by ultrasonography were subject to CT scan to evaluate the number, size, and type of the cysts in liver and lung, confirmed using necropsy. The correlation of numbers between liver cysts and lung cysts was calculated using Pearson analysis. Necropsy indicated a 98% consensus on size, location, number, and activity compared with CT scan. The viable cysts were 53.1% and 50.6% in the liver and lung, respectively. Among the cysts in liver, 35.5%, 9.5%, 5.7%, 10.2%, and 39.1% were Types CE1, CE2, CE3, CE4, and CE5, respectively. The cysts in the lungs, 17.4%, 26.9%, 12.1%, 11.6%, and 32.1%, were Types CE1, CE2, CE3, CE4, and CE5, respectively. A significant correlation was noticed between the number of cysts in liver and those in lung ( R = 0.770, P < 0.001). CT scan is a suitable tool in determining the size and type of cystic hydatid cysts in both liver and lung of sheep. A significant correlation was noticed between the numbers in liver and lung, indicating that lung infection was likely due to the expansion of liver cyst burden pressure.

  16. Correlation of liver stiffness measured by FibroScan with sex and age in healthy adults undergoing physical examination

    Directory of Open Access Journals (Sweden)

    ZHAO Chongshan

    2016-04-01

    Full Text Available ObjectiveTo determine the reference range of liver stiffness in healthy population, and to investigate the influence of age and sex on liver stiffness. MethodsA total of 1794 healthy subjects who underwent physical examination in China National Petroleum Corporation Central Hospital from October 1, 2012 to October 31, 2014 were enrolled, and FibroScan was used to perform liver stiffness measurement (LSM. Since LSM value was not normally distributed, the Wilcoxon rank sum test was used to compare LSM value between male and female patients, the Kruskal-Wallis test was used to compare LSM value between different age groups, and the Spearman's rank correlation analysis was used to analyze the correlation between LSM value and age. The one-sided percentile method was used to determine the range of normal reference values in male and female subjects or in different age groups. ResultsLSM was successfully performed in 1590 patients, and the rate of successful measurement was 88.63%. A total of 107 patients were excluded due to abnormal liver enzymes. The analysis showed that LSM value showed a significant difference between male and female subjects (Z=-4.980, P<0.001, as well as between different age groups (χ2=16.983, P=0.001. Age was positively correlated with LSM value (r=0.087, P=0.001. The reference range was estimated to be ≤7.1 kPa in adults, ≤7.0 kPa in females, and ≤7.2 kPa in males. From the perspective of age, the reference range was estimated to be ≤6.8 kPa in persons aged 20-29 years, ≤6.7 kPa in persons aged 30-44 years, ≤7.8 kPa in persons aged 45-59 years, and ≤8.8 kPa in persons aged 60-74 years. ConclusionLiver stiffness value is influenced by sex and age. Sex and age should be taken into account while performing liver stiffness measurement in healthy subjects.

  17. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  18. Is Contrast Enhanced Ultrasonography a useful tool in a beginner's hand? How much can a Computer Assisted Diagnosis prototype help in characterizing the malignancy of focal liver lesions?

    Science.gov (United States)

    Moga, Tudor Voicu; Popescu, Alina; Sporea, Ioan; Danila, Mirela; David, Ciprian; Gui, Vasile; Iacob, Nicoleta; Miclaus, Gratian; Sirli, Roxana

    2017-08-23

    Contrast enhanced ultrasound (CEUS) improved the characterization of focal liver lesions (FLLs), but is an operatordependent method. The goal of this paper was to test a computer assisted diagnosis (CAD) prototype and to see its benefit in assisting a beginner in the evaluation of FLLs. Our cohort included 97 good quality CEUS videos[34% hepatocellular carcinomas (HCC), 12.3% hypervascular metastases (HiperM), 11.3% hypovascular metastases (HipoM), 24.7% hemangiomas (HMG), 17.5% focal nodular hyperplasia (FNH)] that were used to develop a CAD prototype based on an algorithm that tested a binary decision based classifier. Two young medical doctors (1 year CEUS experience), two experts and the CAD prototype, reevaluated 50 FLLs CEUS videos (diagnosis of benign vs. malignant) first blinded to clinical data, in order to evaluate the diagnostic gap beginner vs. expert. The CAD classifier managed a 75.2% overall (benign vs. malignant) correct classification rate. The overall classification rates for the evaluators, before and after clinical data were: first beginner-78%; 94%; second beginner-82%; 96%; first expert-94%; 100%; second expert-96%; 98%. For both beginners, the malignant vs. benign diagnosis significantly improved after knowing the clinical data (p=0.005; p=0,008). The expert was better than the beginner (p=0.04) and better than the CAD (p=0.001). CAD in addition to the beginner can reach the expert diagnosis. The most frequent lesions misdiagnosed at CEUS were FNH and HCC. The CAD prototype is a good comparing tool for a beginner operator that can be developed to assist the diagnosis. In order to increase the classification rate, the CAD system for FLL in CEUS must integrate the clinical data.

  19. Diagnostic imaging of focal nodular hyperplasis of the liver developing during nitrofurantoin therapy

    Energy Technology Data Exchange (ETDEWEB)

    Anttinen, H.; Ahonen, A.; Leinonen, A.; Kallioinen, M.; Heikkinen, E.S. (University of Oulu (Finland))

    1982-01-01

    An asymptomatic palpable liver tumor developed in a six-year-old girl seven months after commencement of prophylactic nitrofurantoin therapy for recurrent urinary tract infections. The tumor was examined by /sup 99/ sup (m) Tc colloid radionuclide scan, compound ultrasonography and angiography. Ultrasonography demonstrated a large, solid tumor (5x5x8 cm) in the right lobe of the liver which had an echogenic central core surrounded by an area giving low-amplitude echoes. Angiography disclosed that the tumor was well demarcated and hypervascular, containing large tortuous arteries. The uptake of radionuclide in the tumor was normal. The tumor was resected and the pathological findings were typical for focal nodular hyperplasia (FNH) of the liver. The combination of the findings of these three diagnostic imaging methods is probably specific for uncomplicated (FNH), a benign and innocuous tumor of the liver.

  20. Ultrasonography in trauma

    DEFF Research Database (Denmark)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C

    2017-01-01

    BACKGROUND: The Focused Assessment with Sonography in Trauma (FAST) protocol is considered beneficial in emergent evaluation of trauma patients with blunt or penetrating injury and has become integrated into the Advanced Trauma Life Support (ATLS) protocol. No guidelines exist as to the use...... of ultrasonography in trauma in Denmark. We aimed to determine the current use of ultrasonography for assessing trauma patients in Denmark. METHODS: We conducted a nation-wide cross-sectional investigation of ultrasonography usage in trauma care. The first phase consisted of an Internet-based investigation....... Twenty-one (95.5%) of the guidelines included and recommended FAST as part of trauma assessment. The recommended person to perform the examination was the radiologist in n = 11 (50.0%), the surgeon in n = 6 (27.3%), the anesthesiologist in n = 1 (4.5%), and unspecified in n = 3 (13.6%) facilities. FAST...

  1. Liver

    International Nuclear Information System (INIS)

    Bernardino, M.E.; Sones, P.J. Jr.; Barton Price, R.; Berkman, W.A.

    1984-01-01

    Evaluation of the liver for focal lesions is extremely important because the liver is one of the most common sites for metastatic disease. Most patients with metastatic deposits to the liver have a survival rate of about 6 months. Thus, metastatic disease to the liver has an extremely grave prognosis. In the past patients with hepatic lesions had no therapeutic recourse. However, with recent aggressive surgical advances (such as partial hepatectomies) and hepatic artery embolization, survival of patients with hepatic metastases has increased. Thus it is important for noninvasive imaging not only to detect lesions early in their course, but also to give their true hepatic involvement and the extent of the neoplastic process elsewhere in the body. Recent advances in imaging have been rapidly changing over the past 5 years. These changes have been more rapid in computed tomography (CT) and ultrasound than in radionuclide imaging. Thus, the question addressed in this chapter is: What is the relationship of hepatic ultrasound to the other current diagnostic modalities in detecting metastatic liver disease and other focal liver lesions? Also, what is its possible future relationship to nuclear magnetic resonance?

  2. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    International Nuclear Information System (INIS)

    Richter, Daniel; Saito, Nami; Chaudhri, Naved; Härtig, Martin; Ellerbrock, Malte; Jäkel, Oliver; Combs, Stephanie E.; Habermehl, Daniel; Herfarth, Klaus; Durante, Marco; Bert, Christoph

    2014-01-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V 95 ) and 107% (V 107 ) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V 95 and V 107 values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V 95 > 87%, SD < 3%) and overdose (mean V 107 < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment

  3. Ultrasonography of jaundice

    International Nuclear Information System (INIS)

    Cho, Byung Jae; Bae, Sang Hoon; Lee, Seung Ro; Kim, Chu Wan

    1980-01-01

    The importance of ultrasonography in the evaluation of jaundice is stressed with an analysis of 47 cases of jaundice. 31 cases proved to be obstructive and 16 non-obstructive jaundice. Obstructive jaundice could be differentiated from non-obstructive jaundice in all but 2 cases, (96%). The site of obstruction in 31 cases of obstructive jaundice could be predicted correctly in 23 cases of 31, (90%), and cause of obstruction with an accuracy of 35% as well. One can certainly recommend ultrasonography as an initial procedure of choice in jaundice patients

  4. Ultrasonography in abdominal emergencies

    International Nuclear Information System (INIS)

    Risi, D.; Alessi, G.; Meli, C.; Marzano, M.; Fiori, E.; Caterino, S.

    1989-01-01

    From February 1986 to March 1988 113 abdominal US exams were performed in emergency situation to evaluate the accuracy of this methodology: 13 were blunt traumas, 18 post-operative complications. A real-time scanner with a linear probe of 5 MHz was employed. The results were confirmed by surgical and/or clinical and instrumental evaluation. In 81% of the examinations, ultrasonography allowed a diagnosis to be made. Gallbladder and biliary pathologies were the most common findings. The results (sensibility 96%, specificity 88%, accuracy 95%) confirm the affidability of ultrasonography in abdominal emergencies, as shown in literature

  5. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties.

    Science.gov (United States)

    Cournane, S; Cannon, L; Browne, J E; Fagan, A J

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 µm Al(2)O(3) and 3 µm Al(2)O(3), were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s(-1), respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  6. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Cournane, S; Fagan, A J [Department of Medical Physics and Bioengineering, St James' s Hospital, Dublin 8 (Ireland); Cannon, L; Browne, J E [Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Kevin' s Street, Dublin 8 (Ireland)

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 {mu}m Al{sub 2}O{sub 3} and 3 {mu}m Al{sub 2}O{sub 3}, were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s{sup -1}, respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  7. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  8. Surgeon-performed ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias

    2017-01-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment...

  9. Ultrasonography of the Kidney

    DEFF Research Database (Denmark)

    Lindskov Hansen, Kristoffer; Nielsen, Michael Bachmann; Ewertsen, Caroline

    2016-01-01

    Ultrasonography of the kidneys is essential in the diagnosis and management of kidney-related diseases. The kidneys are easily examined, and most pathological changes in the kidneys are distinguishable with ultrasound. In this pictorial review, the most common findings in renal ultrasound...

  10. Emergency surgeon-performed hepatobiliary ultrasonography.

    LENUS (Irish Health Repository)

    Kell, M R

    2012-02-03

    BACKGROUND: Acute hepatobiliary pathology is a common general surgical emergency referral. Diagnosis requires imaging of the biliary tree by ultrasonography. The accuracy and impact of surgeon-performed ultrasonography (SUS) on the diagnosis of emergent hepatobiliary pathology was examined. METHODS: A prospective study, over a 6-month period, enrolled all patients with symptoms or signs of acute hepatobiliary pathology. Patients provided informed consent and underwent both SUS and standard radiology-performed ultrasonography (RUS). SUS was performed using a 2-5-MHz broadband portable ultrasound probe by two surgeons trained in ultrasonography, and RUS using a 2-5-MHz fixed unit. SUS results were correlated with those of RUS and pathological diagnoses. RESULTS: Fifty-three consecutive patients underwent 106 ultrasonographic investigations. SUS agreed with RUS in 50 (94.3 per cent) of 53 patients. SUS accurately detected cholelithiasis in all but two cases and no patient was inaccurately diagnosed as having cholelithiasis at SUS (95.2 per cent sensitivity and 100 per cent specificity). As an overall complementary diagnostic tool SUS provided the correct diagnosis in 96.2 per cent of patients. Time to scan was significantly shorter following SUS (3.1 versus 12.0 h, P < 0.05). CONCLUSION: SUS provides a rapid and accurate diagnosis of emergency hepatobiliary pathology and may contribute to the emergency management of hepatobiliary disease.

  11. Ultrasonic features and radionuclide correlation in liver cell adenoma and focal nodular hyperlasia.

    Science.gov (United States)

    Sandler, M A; Petrocelli, R D; Marks, D S; Lopez, R

    1980-05-01

    Ultrasonic features of three cases of liver cell adenoma (LCA) and two cases of focal nodular hyperplasia (FNH) are presented. These tumors have similar sonographic appearances presenting either as solid masses or containing sonolucent areas due to hemorrhage or necrosis. Although these ultrasonic features in patients with an area of decreased activity on 99mTc-sulfur colloid (Tc-SC) liver scans are not specific for LCA or FNH, such findings in the appropriate clinical setting are suggestive of these lesions. The combination of a solid mass on ultrasonography and a normal Tc-SC radioisotope liver study may be relatively specific for uncomplicated FNH.

  12. Ultrasonic features and radionuclide correlation in liver cell adenoma and focal nodular hyperplasia

    International Nuclear Information System (INIS)

    Sandler, M.A.; Petrocelli, R.D.; Marks, D.S.; Lopez, R.

    1980-01-01

    Ultrasonic features of three cases of liver cell adenoma (LCA) and two cases of focal nodular hyperplasia (FNH) are presented. These tumors have similar sonographic appearances presenting either as solid masses or containing sonolucent areas due to hemorrhage or necrosis. Although these ultrasonic features in patients wth an area of decreased activity on /sup 99m/Tc-sulfur colloid (Tc-SC) liver scans are not specific for LCA or FNH, such findings in the appropriate clinical setting are suggestive of these lesions. The combination of a solid mass on ultrasonography and a normal Tc-SC radioisotope liver study may be relatively specific for uncomplicated FNH

  13. Hepatobiliary scan in neonatal Jaundice

    International Nuclear Information System (INIS)

    Nahar, Nurun; Hasan, Mizanul; Karim, M.A.

    2002-01-01

    Jaundice is more or less common in newborn babies. Through physiological jaundice is most common cause of neonatal jaundice, possibility of obstructive jaundice especially biliary atresia should be kept in mind. Early diagnosis of biliary atresia followed by surgical treatment can save baby's life. Otherwise death is inevitable due to liver failure. Hepatobiliary scan is the imaging study of choice in neonatal jaundice especially when there is persistent conjugated hyperbilirubinaemia. Total 27 newborn babies of suspected biliary atresia, aged 14 days to 4 months were referred to Institute of Nuclear Medicine for Hepatobiliary scan. All of them had high serum bilirubin ranged from 6.0 mg/dl with an average of 9.35 ng/dl serum bilirubin level. Ultrasonography of hepatobiliary system was performed in 14 cases showing normal sized liver in 4 cases and hepatomegaly in 10 cases. Hepatobiliary scan was done with 99m Tc-Mebrofenin (Br IDA) after preparing the baby with phenobarbitone for 3-5 days. 20 (67%) cases were scan positive suggesting biliary atresia (BA) and 7(27%) cases were scan negative. In BA there will be increased hepatic uptake of the radionuclide without any significant excretion even in 24 hours delayed images. Presence of radiotracer in the bowel exclude the diagnosis of BA. Early diagnosis of biliary atresia is very important because in this condition surgery should be performed early (within 60 days of life). Studies suggest that hepatobiliary scan after hepatic stimulation with phenobarbitone for a period of 3-5 days is highly accurate for differentiating biliary atresia from other causes of neonatal jaundice. It is very important to perform hepatobiliary scan in a case of neonatal jaundice to exclude biliary atresia for the sake of baby's life.(author)

  14. Ultrasonography in Obstertrics

    International Nuclear Information System (INIS)

    Lee, Hyon U.

    1982-01-01

    The usefulness of pulse-echo ultrasonography of the practices of obstetrics has been great. It is more reliable than many biochemical and biophysical technics that have been developed in recent years to try to improve pregnancy outcome. When carefully performed and accurately interpreted, it can supply most vital information about the status of the fetus without any known risks to both mother and the fetus itself. The main obstertricalindications of ultrasonography coule be summarized as follows. 1. Diagnosis of early pregnancy. 2. Fetal growth and its maturity. 3. Complications of pregnancy and abnormal pregnancy. a) Vaginal bleeding in early intrauterinepregnancy. b) Multiple pregnancy. c) Ectopic pregnancy d) Hydatidiform mole e) Pelvic mass complicated with pregnancy f) Fetal anomaly 4. Fetal presenation and attitude 5. Placentography

  15. Evaluation of abdominal trauma by computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  16. Evaluation of abdominal trauma by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1986-01-01

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  17. Ultrasonography of ovarian hyperandrogenemia

    Science.gov (United States)

    Kuzmina, Svetlana A.; Zharkin, Nikolay A.

    2001-05-01

    The method of ultrasonography is high informative and widely used in diagnostics of ovarian hyperandrogenaemia. The majority of authors consider that a hyperplasia of a stroma is the main pathognomonic marker of polycystic ovaries (PCO). Still recently swell of a stroma was valued visually, that had subjective nature. We offer for the first time a way of diagnostics of stromal hyperplasia grounded on measurement of a volume of a stroma and ovary with ultrasound method, calculation of the ratio of a volume of the ovary to a volume of a stroma for every patient.

  18. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  19. Comparison of scanning scintigraphy and laparoscopy-biopsy data in the diagnosis of liver diseases. First results based on 35 cases

    International Nuclear Information System (INIS)

    Guillet, Robert.

    1976-01-01

    The liver is implicated in many functions, particularly the bile function, metabolic phenomena concerning glucids, lipids, proteids and coagulation, certain enzyme functions and cleansing processes involving a liver uptake stage followed by a biliary or urinary excretion stage. In view of the complexity of this metabolism it is obviously difficult to investigate the liver functions as a whole by a single set test. Furthermore the analysis of information supplied by scintigraphy implies rather complex technology, especially as these data are not always expressed in a universal form which clinicians can interpret directly. This can raise a barrier between the records and the doctor causing errors to appear not only in the interpretation but also in the indication of what method and products should be used. One of the aims of our future research is to demonstrate the inadequacy of a standard method using a single procedure and only one radioactive substance in hepatobiliary diseases of different mechanisms. To begin with therefore we should like to establish the advantages and limits of 99m technetium in the scanning scintigraphy morphological exploration of the liver, taking laparoscopy as a basis by comparison. We shall then attempt to define the criteria which in our opinion would allow a more rational use of liver scintigraphy in our medical care unit [fr

  20. Tc-99m-BrIDA hepatobiliary (HIDA) scan has a low sensitivity for detecting biliary complications after orthotopic liver transplantation in patients with hyperbilirubinemia

    International Nuclear Information System (INIS)

    Hopkins, L.O.; Feyssa, E.; Parsikia, A.; Khanmoradi, K.; Zaki, R.; Campos, S.; Araya, V.; Tran, H.; Ortiz, J.

    2011-01-01

    Tc-99m-BrIDA hepatobiliary scans are noninvasive tests for detecting biliary leaks and obstructions. However, there is low sensitivity and specificity in patients with hyperbilirubinemia. Biliary complications (BC) are the Achilles heel of orthotopic liver transplantation (OLT). We questioned whether hyperbilirubinemia in liver transplant recipients rendered HIDA scanning less dependable. HIDA findings were compared to endoscopic retrograde cholangiopancreatography, laparotomy, and clinical course. Results were categorized as follows: true positive (TP), true negative (TN), false positive (FP), false negative (FN), or nondiagnostic/inconclusive. We searched for variables associated with erroneous or nondiagnostic tests which we defined as all examinations determined to be FP, FN and/or nondiagnostic/inconclusive. Thirty-four patients underwent a HIDA scan. The sensitivity and specificity were 70 and 100%. The sensitivity of HIDA improved to 100% in patients with a total bilirubin (TB) 5 mg/dl. One FN had a TB <5 mg/dl, but was determined inconclusive due to the roux-en-Y. HIDA scans performed when the total bilirubin was <5 mg/dl had a high sensitivity and specificity for detecting biliary complications after OLT. However, when the total bilirubin exceeded 5 mg/dl, the specificity was still 100% but the numbers of nondiagnostic/inconclusive and FN exams were increased. (author)

  1. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou, Yong-Kang, E-mail: zhouyk2009@163.com; Chen, Yi-Xing, E-mail: chen.yixing@zs-hospital.sh.cn; Shi, Shi-Ming, E-mail: shiming32@126.com; Zeng, Zhao-Chong, E-mail: zeng.zhaochong@zs-hospital.sh.cn [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180 Feng Lin Road, Shanghai 200032 (China)

    2016-07-15

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area between the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z

  2. Gallium-67-citrate scanning in primary cancer of the liver: diagnostic value in the presence of cirrhosis and relation to alpha-fetoprotein

    International Nuclear Information System (INIS)

    Levin, J.; Kew, M.C.

    1975-01-01

    Gallium-67-citrate and /sup 99m/Tc-sulfur colloid scans were performed in 38 South African blacks with primary hepatocellular cancer. Selective uptake of the radionuclide by the tumor occurred in 27 patients (70 percent). In 12 out of 18 patients with associated cirrhosis, 67 Ga was concentrated in the defect or defects visible on the /sup 99m/Tc-sulfur colloid scan, but in the remaining 6 cases (33 percent), the 2 scans were identical and the defects may have been attributed wrongly to cirrhosis. Alpha-fetoprotein (AFP) was detected by immunodiffusion in the serum of 26 patients. Twenty-one of these showed selective uptake of 67 Ga by the tumor as compared with 6 out of 12 patients in whom this protein could not be detected. We were therefore unable to confirm a previous finding of a greater uptake of the radionuclide in AFP-negative primary liver cancer. (auth)

  3. Comparison of findings of spontaneous splenorenal shunt in color Doppler sonography with multislice CT scan (64 slices) in liver transplant candidates

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Mohammadhadi, E-mail: Bagherimh@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hajati, Azadeh, E-mail: azadeh.hajati@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hosseini, Mohammadkazem, E-mail: hosseiniaslm@sums.ac.ir [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Ostad, Seyed Pouria, E-mail: Pouria.Ostad@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of)

    2012-09-15

    Background: Liver transplantation is the only definite treatment for end stage liver disease and it has high costs for the medical system so decreasing its complication and increasing its effectiveness is crucial. One of the factors that affect liver transplantation is the presence of spontaneous splenorenal shunt. Its diagnosis is mainly overlooked in pre-liver transplant patients. Main modality for its diagnosis is multislice CT scan however this is more expensive than sonography. Also, it exposes the patients to ionizing radiation. Considering the advantages of color Doppler ultrasound, studies to determine the sensitivity and specificity for detection of spontaneous splenorenal shunt is essential. Materials and methods: In our study 70 cirrhotic patients who were referred by liver transplant surgeons for evaluation of abdomen by CT and sonograhy were assessed for presence of spontaneous splenorenal shunt, left adrenal varix and left renal vein diameter and velocity and sensitivity and specificity of both modalities were checked. Patients in whom left renal vein could not evaluated by sonography and patients with splenectomy and nutcracker syndrome were excluded. Results: In the point of 10 mm diameter of left renal vein in CT scan there was 78.6% sensitivity and 67.9% specificity for the presence of spontaneous splenorenal shunt. Left adrenal varix in CT had sensitivity of 71.4%, specificity of 100%, and positive predictive value of 100% and negative predictive value of 70% and varix below spleen in CT had sensitivity of 54.8%, specificity of 96.4%, and positive predictive value of 95.8% and negative predictive value of 58.7% for the presence of spontaneous splenorenal shunt. In the point of 8 mm diameter of left renal vein in sonography there was 66.7% sensitivity and 85.7% specificity for the presence of spontaneous splenorenal shunt. For the velocity of more than 35 cm/s of left renal vein in sonography there was 61.9% sensitivity and 82.1% specificity for

  4. Ultrasonography in gastroenterology.

    Science.gov (United States)

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  5. Musculoskeletal ultrasonography in children

    International Nuclear Information System (INIS)

    Teo, E.-L.H.; Strouse, P.J.; Chhem, R.K.

    2002-01-01

    With the development of high-resolution ultrasound transducers, the role of ultrasonography (US) in evaluating the musculoskeletal system has increased. It is now possible to obtain detailed images of bones and soft-tissue structures that were previously unattainable. The advantages of US, when compared with other imaging modalities, are many. It is less expensive than magnetic resonance imaging (MRI) and computed tomography (CT). It does not expose the patient to ionizing radiation, so US examinations can be repeated without harm to the patient. Furthermore, US is performed in real-time, making it possible to assess the musculoskeletal system dynamically, in multiple planes and with contralateral comparison. In experienced hands, US is a quick, noninvasive and cost-effective way to assess the musculoskeletal system in children. It is used to evaluate soft-tissue masses, joint swelling, infections, lesions involving the chest and abdominal walls, bones, muscles and clubfoot deformity and to locate any foreign bodies. (author)

  6. Ultrasonography to quantify hepatic fat content : Validation by H-1 Magnetic Resonance Spectroscopy

    NARCIS (Netherlands)

    Edens, M.A.; van Ooijen, P.M.A.; Post, W.J.; Haagmans, M.J.F.; Kristanto, W.; Sijens, P.E.; van der Jagt, E.J.; Stolk, R.P.

    2009-01-01

    An abundance of fat stored within the liver, or steatosis, is the beginning of a broad hepatological spectrum, usually referred to as fatty liver disease (FLD). For studies on FLD, quantitative hepatic fat ultrasonography would be an appealing study modality. Objective of this study was to develop a

  7. Liver and gastrointestinal tract

    International Nuclear Information System (INIS)

    Shahid, M.A.

    1992-01-01

    Liver is often a site of a variety of diseases. A palpable liver during a routine clinical examination is an important finding and requires further investigations. The availability of non-invasive liver imaging procedures using nuclear, ultrasound, CT (and now MRI) techniques have immensely enhanced diagnostic accuracy in liver diseases. In this Chapter, a detailed description of routinely practised nuclear medicine procedures related to liver is given. Brief reference is also made to other imaging techniques, particularly ultrasonography, only for the purposes of comparison. Most of the information is based on our own clinical experience of past 30 years

  8. Liver and gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Shahid, M A

    1993-12-31

    Liver is often a site of a variety of diseases. A palpable liver during a routine clinical examination is an important finding and requires further investigations. The availability of non-invasive liver imaging procedures using nuclear, ultrasound, CT (and now MRI) techniques have immensely enhanced diagnostic accuracy in liver diseases. In this Chapter, a detailed description of routinely practised nuclear medicine procedures related to liver is given. Brief reference is also made to other imaging techniques, particularly ultrasonography, only for the purposes of comparison. Most of the information is based on our own clinical experience of past 30 years 12 figs, 4 tabs

  9. Surgeon-performed ultrasonography.

    Science.gov (United States)

    Todsen, Tobias

    2017-11-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment of competence in abdominal and head & neck ultrasonography using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. With the use of Messick's unitary framework of validity, five sources of validity evidence were explored: test content, response processes, inter-nal structure, relations to other variables, and consequences. Research paper I examined validity evidence for the use of the OSAUS scale to assess physicians' abdominal point-of-care US competence in an experimental setting using patient cases with and without pathological conditions. The RESULTS provided validity evidence of the internal structure of the OSAUS scale and a deci-sion study predicted that four cases and two raters or five cases and one rater could ensure sufficient reliability in future test setups. The relation to other variables was supported by a signifi-cant difference in scores between US experience levels, and by a strong correlation between the OSAUS score and diagnostic accuracy. Research paper II explored the transfer of learning from formal point-of-care US training to performance on patients in a randomized controlled study. The RESULTS supported validity evi-dence regarding OSAUS scores' relation to other variables by demonstrating a significant discrimination in the progress of training-a more refined validity evidence than the relation to difference experience levels. The RESULTS showed that physicians could transfer the skills learned on an ultrasonography course to improved US performance and diagnostic accuracy on patients. However, the RESULTS also indicated that following an initial course, additional training is needed for physicians to achieve competence in US

  10. Anicteric dilatation of the biliary tree demonstrated by ultrasound 131I rose bengal liver scan and PTC

    International Nuclear Information System (INIS)

    Kapoor, R.; Saha, M.M.; Gupta, A.K.

    1991-01-01

    An uncommon case of gross dilatation of biliary tract, without clinical or biochemical evidence of jaundice, is presented. Dilatation of bile ducts was initially demonstrated on ultrasound and it was subsequently confirmed by 131 I rose bengal liver can, PTC and at surgery. (author). 6 refs., 3 figs

  11. Novel route synthesis of porous and solid gold nanoparticles for investigating their comparative performance as contrast agent in computed tomography scan and effect on liver and kidney function

    Directory of Open Access Journals (Sweden)

    Aziz F

    2017-02-01

    Full Text Available Farooq Aziz,1,2 Ayesha Ihsan,1 Aalia Nazir,2 Ishaq Ahmad,3 Sadia Zafar Bajwa,1 Asma Rehman,1 Abdoulaye Diallo,4 Waheed S Khan1 1Nanobiotechnology Group, National Institute for Biotechnology and Genetic Engineering (NIBGE, Faisalabad, 2Department of Physics, Islamia University of Bahawalpur, Bahawalpur, 3National Center for Physics, Quaid-I-Azam University, Islamabad, Pakistan; 4Laboratory of Photonics and Nano-Fabrication, Faculty of Science and Technology, Cheikh Anta Diop University of Dakar (UCAD, Dakar-Fann Dakar, Senegal Abstract: Gold nanoparticles (GNPs with dimension in the range of 1–100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs and solid gold nanoparticles (SGNPs. PGNPs of size 35 nm were fabricated by reduction of gold (III solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λmax 560 nm and SGNPs (λmax 548 nm were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU than SGNPs (26 HU. To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV injection including liver function profile, renal (kidney function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as

  12. Novel route synthesis of porous and solid gold nanoparticles for investigating their comparative performance as contrast agent in computed tomography scan and effect on liver and kidney function.

    Science.gov (United States)

    Aziz, Farooq; Ihsan, Ayesha; Nazir, Aalia; Ahmad, Ishaq; Bajwa, Sadia Zafar; Rehman, Asma; Diallo, Abdoulaye; Khan, Waheed S

    2017-01-01

    Gold nanoparticles (GNPs) with dimension in the range of 1-100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs) and solid gold nanoparticles (SGNPs). PGNPs of size 35 nm were fabricated by reduction of gold (III) solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λ max 560 nm) and SGNPs (λ max 548 nm) were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU) than SGNPs (26 HU). To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV) injection including liver function profile, renal (kidney) function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as compared to SGNPs 6 hours after injection. Our findings suggested that the novel PGNPs enhance CT scan image with higher efficacy as compared to SGNPs. The results showed that IV administration of synthesized PGNPs increases the levels of aspartate aminotransferase (AST), alkaline phosphate (ALP), serum creatinine, and blood glucose, whereas that of SGNPs increases the levels of AST, ALP, and blood glucose.

  13. Transthoracic Ultrasonography for Clinicians

    Directory of Open Access Journals (Sweden)

    Morné Johan Vorster

    2015-04-01

    Full Text Available Transthoracic ultrasonography (US has become an essential tool for respiratory, emergency, and critical care physicians. It can be performed with basic equipment and by personnel with minimum training as a modality for the evaluation of a wide range of thoracic pathologies. Its advantages include immediate application at the point of care, low cost, and lack of radiation. The main indications for transthoracic US are the qualitative and quantitative assessment of pleural effusions, pleural thickening, diaphragmatic pathology, as well as chest wall and pleural tumors. Transthoracic US is also useful in visualizing pulmonary pathologies that abut the pleura, such as pneumonic consolidation and interstitial syndromes, including pulmonary edema. Transthoracic US is more sensitive than the traditional chest radiograph in the detection of pneumothoraces, and it is useful in diagnosing skeletal abnormalities such as rib fractures. It is the ideal tool to guide transthoracic procedures, including thoracocentesis and pleural biopsy. Moreover, transthoracic US-guided procedures can be performed by a single clinician with no sedation and minimal monitoring. Transthoracic US-guided fine needle aspiration and/or cutting needle biopsy of extrathoracic lymph nodes and lesions arising from the chest wall, pleura, peripheral lung, and mediastinum are safe to perform and have a high yield in the of hands of experienced clinicians. Transthoracic US can also potentially guide the aspiration and biopsy of diffuse pulmonary infiltrates, consolidations, and lung abscesses. Moreover, transthoracic US may be used in the detection of pulmonary embolism

  14. Advances in diagnostic ultrasonography.

    Science.gov (United States)

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  15. Cutaneous features seen in primary liver cell (Hepatocellular ...

    African Journals Online (AJOL)

    kemrilib

    features associated with the entity as a possible aid to diagnosis cutaneous features being considered a cheap tool that can help ... liver cell cancer (PLCC) and cancer of the breast and ... laboratory based -abdominal ultrasonography, liver.

  16. The Impact of Transient Hepatic Attenuation Differences in the Diagnosis of Pseudoaneurysm and Arteriovenous Fistula on Follow-Up CT Scans after Blunt Liver Trauma

    Directory of Open Access Journals (Sweden)

    Andreas Hjelm Brandt

    2014-09-01

    Full Text Available A feared complication to liver trauma is delayed vascular complication, such as pseudoaneurysm and arteriovenous fistula (PS/AF seen as focal enhancement on contrast-enhanced computed tomography (CT in the arterial phase. A hyperdense area termed transient hepatic attenuation difference (THAD representing altered hepatic blood flow can be seen in the arterial phase near the liver lesion. The objective of this study was to describe THAD and PS/AF on follow-up CT after blunt liver trauma, and to evaluate if THAD influenced the evaluation of PS/AF. Three radiology residents retrospectively evaluated scans of 78 patients. The gold standard for PS/AF was an evaluation by an experienced senior radiologist, while THAD was a consensus between the residents. PS/AF was present in 14% and THAD in 54%. THAD was located in the periphery of the lesion with hazy borders and mean HU levels of 100, while PS/AF was located within the lesion with focal enhancement and mean HU levels of 170 (p < 0.05. In evaluation of PS/AF, the likelihood of agreement between the observers and the gold standard was 89% when THAD was present, and 98% when THAD was absent (p = 0.04. THAD is common and can hamper the evaluation of PS/AF.

  17. Solitary fibrous tumor of the liver: a case report

    Directory of Open Access Journals (Sweden)

    Ying Li-Xiong

    2011-03-01

    Full Text Available Abstract Hepatic solitary fibrous tumor (SFT is a rare tumor originating from the mesenchyme. Here we report a new case of SFT in the liver and review the clinical presentation, radiological and operative findings, diagnosis, treatment, and outcome. The patient was a 59-year-old man who presented with progressive fatigue for 3 months and an abdominal mass for 3 days. On laboratory tests, no abnormality was detected except that abdominal ultrasonography revealed a 9.0 × 6.2 cm hypoechogenic mass in the left lobe of the liver. A computed tomographic scan confirmed a hypodense lesion in the left lobe of the liver. The patient underwent left hepatectomy. SFT was diagnosed on the basis of histopathological findings. The patient was free from all symptoms and had no signs of local recurrence after 24 months' follow up.

  18. SU-F-T-189: Dosimetric Comparison of Spot-Scanning Proton Therapy Techniques for Liver Tumors Close to the Skin Surface

    International Nuclear Information System (INIS)

    Takao, S; Matsuzaki, Y; Matsuura, T; Umegaki, K; Fujii, Y; Fujii, T; Katoh, N; Shimizu, S; Shirato, H

    2016-01-01

    Purpose: Spot-scanning technique has been utilized to achieve conformal dose distribution to large and complicated tumors. This technique generally does not require patient-specific devices such as aperture and compensator. The commercially available spot-scanning proton therapy (SSPT) systems, however, cannot deliver proton beams to the region shallower than 4 g/cm2. Therefore some range compensation device is required to treat superficial tumors with SSPT. This study shows dosimetric comparison of the following treatment techniques: (i) with a tabletop bolus, (ii) with a nozzle-mounted applicator, and (iii) without any devices and using intensity-modulated proton therapy (IMPT) technique. Methods: The applicator composed of a combination of a mini-ridge filter and a range shifter has been manufactured by Hitachi, Ltd., and the tabletop bolus was made by .decimal, Inc. Both devices have been clinically implemented in our facility. Three patients with liver tumors close to the skin surface were examined in this study. Each treatment plan was optimized so that the prescription dose of 76 Gy(RBE) or 66 Gy(RBE) would be delivered to 99% of the clinical target volume in 20 fractions. Three beams were used for tabletop bolus plan and IMPT plan, whereas two beams were used in the applicator plan because the gantry angle available was limited due to potential collision to patient and couch. The normal liver, colon, and skin were considered as organs at risk (OARs). Results: The target heterogeneity index (HI = D_5/D_9_5) was 1.03 on average in each planning technique. The mean dose to the normal liver was considerably less than 20 Gy(RBE) in all cases. The dose to the skin could be reduced by 20 Gy(RBE) on average in the IMPT plan compared to the applicator plan. Conclusion: It has been confirmed that all treatment techniques met the dosimetric criteria for the OARs and could be implemented clinically.

  19. SU-F-T-189: Dosimetric Comparison of Spot-Scanning Proton Therapy Techniques for Liver Tumors Close to the Skin Surface

    Energy Technology Data Exchange (ETDEWEB)

    Takao, S; Matsuzaki, Y [Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Hokkaido (Japan); Matsuura, T; Umegaki, K [Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido (Japan); Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Hokkaido (Japan); Fujii, Y; Fujii, T [Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido (Japan); Katoh, N [Department of Radiation Oncology, Hokkaido University Hospital, Sapporo, Hokkaido (Japan); Shimizu, S; Shirato, H [Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Hokkaido (Japan); Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido (Japan)

    2016-06-15

    Purpose: Spot-scanning technique has been utilized to achieve conformal dose distribution to large and complicated tumors. This technique generally does not require patient-specific devices such as aperture and compensator. The commercially available spot-scanning proton therapy (SSPT) systems, however, cannot deliver proton beams to the region shallower than 4 g/cm2. Therefore some range compensation device is required to treat superficial tumors with SSPT. This study shows dosimetric comparison of the following treatment techniques: (i) with a tabletop bolus, (ii) with a nozzle-mounted applicator, and (iii) without any devices and using intensity-modulated proton therapy (IMPT) technique. Methods: The applicator composed of a combination of a mini-ridge filter and a range shifter has been manufactured by Hitachi, Ltd., and the tabletop bolus was made by .decimal, Inc. Both devices have been clinically implemented in our facility. Three patients with liver tumors close to the skin surface were examined in this study. Each treatment plan was optimized so that the prescription dose of 76 Gy(RBE) or 66 Gy(RBE) would be delivered to 99% of the clinical target volume in 20 fractions. Three beams were used for tabletop bolus plan and IMPT plan, whereas two beams were used in the applicator plan because the gantry angle available was limited due to potential collision to patient and couch. The normal liver, colon, and skin were considered as organs at risk (OARs). Results: The target heterogeneity index (HI = D{sub 5}/D{sub 95}) was 1.03 on average in each planning technique. The mean dose to the normal liver was considerably less than 20 Gy(RBE) in all cases. The dose to the skin could be reduced by 20 Gy(RBE) on average in the IMPT plan compared to the applicator plan. Conclusion: It has been confirmed that all treatment techniques met the dosimetric criteria for the OARs and could be implemented clinically.

  20. Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients

    NARCIS (Netherlands)

    Bernatowicz, K; Lomax, Antony J.; Knopf, A

    2013-01-01

    In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the

  1. Ultrasonography in the evaluation of tongue and mouth pathology

    International Nuclear Information System (INIS)

    Lee, Chan Wha; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Tae; Hong, Won Pyo; Park, Hyung Sik

    1991-01-01

    The evaluation of the tongue and mouth floor using the CT scan can be limited due to dental artifacts. Because the therapeutic plan depends on the nature and the cancer staging of lesions, it is essential to obtain accurate evaluation of lesions. In this study are explored the of Ultrasonography for the evaluation of tongue and mouth floor pathology. We have obtained ultrasonograms in 20 patients who had benign and malignant lesions in the tongue and mouth floor. Comparative analysis was made on 15 patients who underwent both CT and ultrasonography. We used the bimanual compression technique and the phonation technique during real-time scanning. Out of 15 cases, six had tongue cancer, and seven of them had cancer of the mouth floor. The other cases included a ranula, a dermoid cyst, a Ludwig's angina, and abscess of salivary gland, and one care with stones of the submandibular gland. All the benign and malignant masses appeared hypoechoic. Even though the lesions of tongue and mouth floor could not be evaluated by CT scan due to dental artifacts and extremely small size in 5 cases, ultrasonogram using the bimanual compression technique demonstrated good localization of the lesion, and also was greatly helpful in visualizing the invasion of the surrounding structures. Ultrasonography of the tongue and mouth floor proved to be superior to the CT scan not only in delineating the size and extent of the primary lesion, but also in visualizing invasion of surrounding structures

  2. Ultrasonic features and radionuclide correlation in liver cell adenoma and focal nodular hyperplasia. [/sub 99m/Tc-sulfur colloid; /sup 131/I-rose bengal; /sup 67/Ga-citrate

    Energy Technology Data Exchange (ETDEWEB)

    Sandler, M.A.; Petrocelli, R.D.; Marks, D.S.; Lopez, R.

    1980-05-01

    Ultrasonic features of three cases of liver cell adenoma (LCA) and two cases of focal nodular hyperplasia (FNH) are presented. These tumors have similar sonographic appearances presenting either as solid masses or containing sonolucent areas due to hemorrhage or necrosis. Although these ultrasonic features in patients wth an area of decreased activity on /sup 99m/Tc-sulfur colloid (Tc-SC) liver scans are not specific for LCA or FNH, such findings in the appropriate clinical setting are suggestive of these lesions. The combination of a solid mass on ultrasonography and a normal Tc-SC radioisotope liver study may be relatively specific for uncomplicated FNH.

  3. Accuracy of ultrasonography in the detection of severe hepatic lipidosis in cats.

    Science.gov (United States)

    Yeager, A E; Mohammed, H

    1992-04-01

    The accuracy of ultrasonography in detection of feline hepatic lipidosis was studied retrospectively. The following ultrasonographic criteria were associated positively with severe hepatic lipidosis: the liver hyperechoic, compared with falciform fat; the liver isoechoic or hyperechoic, compared with omental fat; poor visualization of intrahepatic vessel borders; and increased attenuation of sound by the liver. In a group of 36 cats with clinically apparent hepatobiliary disease and in which liver biopsy was done, liver hyperechoic, compared with falciform fat, was the best criterion for diagnosis of severe hepatic lipidosis with 91% sensitivity, 100% specificity, and 100% positive predictive value.

  4. Ultrasonography of the equine shoulder

    International Nuclear Information System (INIS)

    Dik, K.J.

    1996-01-01

    Six horses with shoulder injuries were presented in this report with emphasis on the use of ultrasonography vs. radiography in diagnosis. The two imaging modalities represented valuable and complementary diagnostic procedures. Two horses had fracture fragments of the lateral humeral tuberosity, the accurate ultrasonographic findings encouraging clearer radiographic identification by oblique projections. In one horseultrasonography enabled more accurate localization of calcification within the supraspinatus muscle. In the remaining three cases ultrasonography visualized distension of the bicipital bursa due to aseptic bursitis, bursal hemorrhage, or associated with injury of the biceps brachii muscle and the underlying intermediate humeral tubercle, the bony involvement more clearly demonstrated radiographically

  5. Randomized clinical trial of laparoscopic ultrasonography before laparoscopic colorectal cancer resection

    DEFF Research Database (Denmark)

    Ellebaek, S B; Fristrup, C W; Hovendal, C

    2017-01-01

    BACKGROUND: Intraoperative ultrasonography during open surgery for colorectal cancer may be useful for the detection of unrecognized liver metastases. Laparoscopic ultrasonography (LUS) for the detection of unrecognized liver metastasis has not been studied in a randomized trial. This RCT tested...... in the LUS than in the control group (7·8 (95 per cent c.i. 3·8 to 13·8) and 0·8 (0 to 4·2) per cent respectively; P = 0·010), but the suspected M1 disease was benign in half of the patients. CONCLUSION: Routine LUS during resection of colorectal cancer is not recommended. Registration number: NCT02079389...

  6. Ultrasonography of the pediatric hip and spine

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeo Ryang; Koo, Joon Bun [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies.

  7. Ultrasonography of the pediatric hip and spine

    International Nuclear Information System (INIS)

    Kang, Yeo Ryang; Koo, Joon Bun

    2017-01-01

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies

  8. Prenatal diagnosis of hypophosphatasia congenita using ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Guguloth, Ashwitha [Dept. of Radiology, Bangalore Medical College and Research Institute, Bangalore (India); Aswani, Yashant; Anandpara, Karan Manoj [Dept. of Radiology, Seth G S Medical College and KEM Hospital, Mumbai (India)

    2016-01-15

    Congenital hypophosphatasia is a rare fatal skeletal dysplasia. Antenatal determinants of Epub ahead of print lethality include small thoracic circumference with pulmonary hypoplasia and severe micromelia. These features were present in the fetus of a 25-year-old female who came for an anomaly scan in her second trimester of pregnancy. Additional findings of generalized demineralization and osteochondral spurs led to the diagnosis of hypophosphatasia congenita. The pregnancy was terminated, and the findings were confirmed on autopsy. Common differential diagnoses with clues to diagnose the above mentioned condition have been discussed here. Early and accurate detection of this medical condition is important as no treatment has been established for this condition. Therefore, antenatal ultrasonography helps in diagnosing and decision making with respect to the current pregnancy and lays the foundation for the genetic counseling of the couple.

  9. Computed tomography of liver tumors, 2. Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor by dynamic CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Akira; Fukuoka, Haruhito; Kashiwado, Kouzou; Ichiki, Toshio; Makidono, Yoko [Hiroshima Red Cross Hospital (Japan)

    1984-02-01

    Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor was attempted using dynamic CT scanning. Homogeneous and patchy types were peculiar to hepatocellular carcinoma, and ring-like type to metastatic hepatic tumor. However, with no enhancement, hepatocellular carcinoma could not be denied. Hepatocellular carcinoma was characterized by the enhancement shown on the early stage of dynamic CT. Ring enhancement was not visualized on dynamic CT but visualized on conventional contrast enhanced CT in hepatocellular carcinomas; it was visualized on conventional contrast enhanced CT and on dynamic CT in metastatic hepatic tumors.

  10. The value of fetal ultrasonography and magnetic resonance imaging in the assessment of diaphragmatic hernias

    International Nuclear Information System (INIS)

    Amim, Bruno; Guerra, Fernando; Marchiori, Edson; Gasparetto, Emerson Leandro

    2008-01-01

    To demonstrate the relevance of ultrasonography and magnetic resonance imaging findings in the prenatal characterization and prognostic evaluation in cases of congenital diaphragmatic hernia. Materials And Methods: Fourteen pregnant women (mean gestational age = 28.7 weeks) who had undergone ultrasonography for suspicion of fetuses with congenital diaphragmatic hernia were assessed by means of magnetic resonance imaging on a 1.5 tesla equipment, following the standard protocol. Two radiologists evaluated the images and the findings were defined by consensus. Results: Twelve fetuses had left diaphragmatic hernia and two, right diaphragmatic hernia. Ultrasonography showed the fetal liver inside the thorax of five fetuses (three with left diaphragmatic hernia, and two with right diaphragmatic hernia) and magnetic resonance imaging in eight fetuses (six with left diaphragmatic hernia, and two with right diaphragmatic hernia). Stomach and small bowel loop herniation was observed in all of the fetuses with left diaphragmatic hernia (n = 12) at both magnetic resonance imaging and ultrasonography. Eight fetuses (seven with left diaphragmatic hernia and one with right diaphragmatic hernia) survived after surgical treatment. Conclusion: Ultrasonography and magnetic resonance imaging are complementary imaging methods in the evaluation of congenital diaphragmatic hernia. Magnetic resonance imaging is a helpful diagnostic method complementary to ultrasonography for evaluation of the fetal liver positioning, considering its relevance as a prognostic factor in cases of congenital diaphragmatic hernia. (author)

  11. Ultrasonography of the Rotator Cuff

    International Nuclear Information System (INIS)

    Yoon, Yong Cheol

    2006-01-01

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  12. Ultrasonography of the Rotator Cuff

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yong Cheol [Samsung Medica Center, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  13. SU-F-T-121: Abdominal Compression Effectively Reduces the Interplay Effect and Enables Pencil Beam Scanning Proton Therapy of Liver Tumors

    International Nuclear Information System (INIS)

    Souris, K; Glick, A; Kang, M; Lin, H; McDonough, J; Simone, C; Solberg, T; Ben-Josef, E; Lin, L; Janssens, G; Sterpin, E; Lee, J

    2016-01-01

    Purpose: To study if abdominal compression can reduce breathing motion and mitigate interplay effect in pencil beam scanning proton therapy (PBSPT) treatment of liver tumors in order to better spare healthy liver volumes compared with photon therapy. Methods: Ten patients, six having large tumors initially treated with IMRT and four having small tumors treated with SBRT, were replanned for PBSPT. ITV and beam-specific PTVs based on 4D-CT were used to ensure target coverage in PBSPT. The use of an abdominal compression belt and volumetric repainting was investigated to mitigate the interplay effect between breathing motion and PBSPT dynamic delivery. An in-house Matlab script has been developed to simulate this interplay effect. The dose is computed on each phase individually by sorting all spots according to their simulated delivery timing. The final dose distribution is then obtained by accumulating all dose maps to a reference phase. Results: For equivalent target coverage PBSPT reduced average healthy liver dose by 9.5% of the prescription dose compared with IMRT/SBRT. Abdominal compression of 113.2±42.2 mmHg was effective for all 10 patients and reduced average motion by 2.25 mm. As a result, the average ITV volume decreased from 128.2% to 123.1% of CTV volume. Similarly, the average beam-specific PTV volume decreased from 193.2% to 183.3%. For 8 of the 10 patients, the average motion was reduced below 5 mm, and up to 3 repainting were sufficient to mitigate interplay. For the other two patients with larger residual motion, 4–5 repainting were needed. Conclusion: We recommend evaluation of the 4DCT motion histogram following simulation and the interplay effect following treatment planning in order to personalize the use of compression and volumetric repainting for each patient. Abdominal compression enables safe and more effective PBS treatment of liver tumors by reduction of motion and interplay effect. Kevin Souris is supported by IBA and Televie Grant

  14. SU-F-T-121: Abdominal Compression Effectively Reduces the Interplay Effect and Enables Pencil Beam Scanning Proton Therapy of Liver Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Souris, K [Universite catholique de Louvain, Brussels (Belgium); University of Pennsylvania, Philadelphia, PA (United States); Glick, A; Kang, M; Lin, H; McDonough, J; Simone, C; Solberg, T; Ben-Josef, E; Lin, L [University of Pennsylvania, Philadelphia, PA (United States); Janssens, G [IBA, Louvain-la-neuve (Belgium); Sterpin, E [Universite catholique de Louvain, Brussels (Belgium); KU Leuven, Leuven (Belgium); Lee, J [Universite catholique de Louvain, Brussels (Belgium)

    2016-06-15

    Purpose: To study if abdominal compression can reduce breathing motion and mitigate interplay effect in pencil beam scanning proton therapy (PBSPT) treatment of liver tumors in order to better spare healthy liver volumes compared with photon therapy. Methods: Ten patients, six having large tumors initially treated with IMRT and four having small tumors treated with SBRT, were replanned for PBSPT. ITV and beam-specific PTVs based on 4D-CT were used to ensure target coverage in PBSPT. The use of an abdominal compression belt and volumetric repainting was investigated to mitigate the interplay effect between breathing motion and PBSPT dynamic delivery. An in-house Matlab script has been developed to simulate this interplay effect. The dose is computed on each phase individually by sorting all spots according to their simulated delivery timing. The final dose distribution is then obtained by accumulating all dose maps to a reference phase. Results: For equivalent target coverage PBSPT reduced average healthy liver dose by 9.5% of the prescription dose compared with IMRT/SBRT. Abdominal compression of 113.2±42.2 mmHg was effective for all 10 patients and reduced average motion by 2.25 mm. As a result, the average ITV volume decreased from 128.2% to 123.1% of CTV volume. Similarly, the average beam-specific PTV volume decreased from 193.2% to 183.3%. For 8 of the 10 patients, the average motion was reduced below 5 mm, and up to 3 repainting were sufficient to mitigate interplay. For the other two patients with larger residual motion, 4–5 repainting were needed. Conclusion: We recommend evaluation of the 4DCT motion histogram following simulation and the interplay effect following treatment planning in order to personalize the use of compression and volumetric repainting for each patient. Abdominal compression enables safe and more effective PBS treatment of liver tumors by reduction of motion and interplay effect. Kevin Souris is supported by IBA and Televie Grant

  15. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  16. Positron Scanning of Liver and Pancreas; Exploration de Foie et du Pancreas par les Positrons; Pozitronoskopiya pecheni i podzheludochnoj zhelezy; Exploracion del higado y del pancreas mediante positrones

    Energy Technology Data Exchange (ETDEWEB)

    Aronow, S; Thors, R; Brownell, G L [Physics Research Laboratory and Department of Surgery, Massachusetts General Hospital, Boston, MA (United States)

    1959-07-01

    The success of the positron scanning technique in the localization of brain tumors has suggested its application to other organs. Zinc-62 is used in an attempt to delineate the pancreas and copper-64 in various forms is used to delineate the liver. The problem of visualizing the pancreas is particularly difficult because of its small size and the presence of large organs in the vicinity which concentrate zinc. Several approaches to this problem are discussed. Copper-64 in simple ionic form and in the form of copper versenate concentrate to a marked degree in the liver. Positron scans of the liver would seem to offer considerable promise for successful 'diagnosis of various liver disorders. Data is presented on the distribution of several isotopes and compounds in animals. (author) [French] Devant le succes avec lequel la technique de detection par les positrons a ete utilisee pour la localisation des tumeurs du cerveau, on a ete amene a l'appliquer a d'autres organes. On s'est servi de zinc-62 pour tenter de determiner le contour du pancreas, et de cuivre-64, sous diverses formes, pour le contour du foie. Il est particulieremen t difficile de rendre visible le pancreas en raison de sa petite taille et de la presence d'organes voisins de grandes dimensions, qui concentrent le zinc. Les auteurs etudient plusieurs procedes par lesquels on s'est efforce de resoudre ce probleme. Le cuivre-64 sous forme ionique simple et sous forme de sel de l'acide ethylene-diamino-tetra-acetique se ooncentre fortement dans le foie. L'exploration du foie a l'aide des positrons parait devoir faciliter considerablemen t le diagnostic de differents troubles hepatiques. Les auteurs donnent des indications sur la repartition de plusieurs isotopes et composes chez des animaux. (author) [Spanish] El exito de la tecnica de exploracion mediante positrones en la localization de tumores cerebrales aconseja su aplicacion a otros organos. El zinc-62 y el cobre-64 en diferentes formas se utilizan

  17. Ultrasonography of the canine pancreas

    Directory of Open Access Journals (Sweden)

    Michelle L Avante

    2018-01-01

    Full Text Available This study describes the ultrasonographic techniques currently used in the evaluation of the canine pancreas. Ultrasonography was the first method to enable direct visualization of the pancreas in humans and it has been subsequently applied to animals. Currently, it is the method of choice for pancreatic evaluation and is essential as a diagnostic tool in the detection of abnormalities, especially tumors. Innovative equipment technology has led to the emergence of techniques complementary to B-mode ultrasound; such as Doppler, elastography, and contrast-enhanced ultrasonography, which have enabled more accurate diagnosis. Doppler provides information on vascular architecture and the hemodynamic aspect of blood vessels in multiple organs. ARFI elastography provides detailed images of the alterations detected by conventional examination (qualitative method and assists in differentiating between benign and malignant processes (quantitative method. Microbubble contrast agents determine parameters related to homogeneous and heterogeneous filling of organs with microbubbles, mainly nodular areas, thus defining high and low intensity patterns.

  18. Ultrasonography findings of gastric carcinoma

    International Nuclear Information System (INIS)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young

    1985-01-01

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen

  19. Ultrasonography findings of gastric carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1985-12-15

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen.

  20. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  1. Thyroid ultrasonography: Pitfalls and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seon hyeong; Kim, Eun Kyung; Kim, Soo Jin; Kwak, Jin Young [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    Thyroid ultrasonography (US) plays a key role in the diagnosis and management of thyroid-related diseases. The aim of this article was to illustrate various pitfalls that can occur in utilizing thyroid US and techniques to prevent them. In this article, we present cases demonstrating the common pitfalls associated with US equipment, performance, normal thyroid structures, misinterpretations, and surrounding structures. Knowledge of these areas is essential to avoid misdiagnosis or improper disease management.

  2. Comparison of helical computed tomography and ultrasonography in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Nafees, M.; Abbas, G.; Sarwar, S.

    2010-01-01

    The objective of study is to compare the diagnostic accuracy of helical computed tomography and ultrasonography in acute appendicitis using histopathology as gold standard. Thirty cases of clinically suspected acute appendicitis were included in the study selected on non probability convenience sampling technique. Computed tomography and graded compression ultrasonography of right lower quadrant of abdomen were conducted and results compared with histopathological findings. Amongst 30 patients who underwent computed tomography and graded compression ultrasonography examinations of right lower quadrant for diagnosis of acute appendicitis, on computed tomography 19 were diagnosed with acute appendicitis, 10 were diagnosed as not having the disease and 01 patient diagnosed as not having appendicitis on computed tomography did not improve clinically, was operated upon and histopathology proved it as acute appendicitis. While on graded compression ultrasonography 15 were diagnosed with acute appendicitis, 11 were diagnosed as not having the disease and 04 patients diagnosed as not having appendicitis on ultrasonography, did not improve clinically, were operated upon and histopathology proved it as acute appendicitis. This showed that CT scan has sensitivity of 95%, specificity 100%, positive predictive value 100%, negative predictive value 90.91% and overall accuracy of 96.67% while ultrasonography has sensitivity of 78.9%, specificity 100%, positive predictive value 100%, negative predictive value 73.33% and overall accuracy of 86.67%. We concluded that Helical computed tomography is highly accurate in diagnosing acute appendicitis as compared to ultrasonography and it helps to reduce negative appendectomy rate. (author)

  3. Fatty Liver

    International Nuclear Information System (INIS)

    Filippone, A.; Digiovandomenico, V.; Digiovandomenico, E.; Genovesi, N.; Bonomo, L.

    1991-01-01

    The authors report their experience with the combined use of US and CT in the study of diffuse and subtotal fatty infiltration of the liver. An apparent disagreement was initially found between the two examinations in the study of fatty infiltration. Fifty-five patients were studied with US and CT of the upper abdomen, as suggested by clinics. US showed normal liver echogenicity in 30 patients and diffuse increased echogenicity (bright liver) in 25 cases. In 5 patients with bright liver, US demonstrated a solitary hypoechoic area, appearing as a 'skip area', in the quadrate lobe. In 2 patients with bright liver, the hypoechoic area was seen in the right lobe and exhibited no typical US features of 'Skip area'. Bright liver was quantified by measuring CT density of both liver and spleen. The relative attenuation values of spleen and liver were compared on plain and enhanced CT scans. In 5 cases with a hypoechoic area in the right lobe, CT findings were suggestive of hemangioma. A good correlation was found between broght liver and CT attenuation values, which decrease with increasing fat content of the liver. Moreover, CT attenuation values confirmed US findings in the study of typical 'skip area', by demonstrating normal density - which suggests that CT can characterize normal tissue in atypical 'skip area'

  4. Angiosarcoma of the liver : a case report

    International Nuclear Information System (INIS)

    Park, Byung Ran; Park, Weon Gyoo; Kim, Byong Geun; Kim, Se Jong; Ko, Kang Seok; Kim, Jae Hong

    1997-01-01

    We report a case of histopathologically confirmed hepatic angiosarcoma. A 29-year old patient was admitted with fever and palpable tender mass in the right upper abdomen. On ultrasonography, a large, well circumscribed mixed echoic mass was seen in the right lobe of the liver. On CT scan, irregular enhancement was seen mainly in the peripheral portion of the mass ; the central portion was not enhanced. The mass showed low signal intensity on TIWI, and high signal intensity on T2WI. Peripheral nodular enhancement was noted on Gd-enhanced MR images; in the peripheral portion of the mass, 99mTc-RBC scintigraphy revealed persistently increased uptake, and in this same portion, celiac angiography showed displacement of hepatic arteries and irregular vessels

  5. Is CEUS (contrast enhanced ultrasonography a useful tool in a beginner’s hands? How much can CAD (computer assisted diagnosis prototype help us in the characterization of malignancy in focal lesions of the liver?

    Directory of Open Access Journals (Sweden)

    Tudor Voicu Moga1,

    2016-12-01

    Full Text Available OBJECTIVES CEUS improved the characterization of focal lesions of the liver (FLLs, but it remains an operator-dependent method. The goal of this scientific paper was to test a computer assisted diagnosis (CAD prototype. MATERIALS AND METHODS 97 CEUS videos [34% hepatocellular carcinomas (HCC, 12.3% hypervascular metastases (HiperM, 11.3% hypovascular metastases (HipoM, 24.7% hemangiomas (HMG, 17.5% focal nodular hyperplasia (FNH] were used to develop a CAD prototype based on an algorithm that tested a binary decision classifier. Two young MDs, two experts and the CAD prototype, reevaluated 50 CEUS videos (diagnosis of benign vs. malignant lesions, in order to evaluate the beginner vs. expert diagnostic gap, the first being blinded by clinical data. RESULTS I-Beginner misdiagnosed 4/10-FNH, 3/10-HCC, 2/10-HMG, 1/10-HiperM, 1/10-HipoM. After being informed about the clinical data 2/10-FNH, 1/10-HCC. II-beginner misdiagnosed: 3/10-FNH; 3/10-HCC, 2/10- HMG, 1/10-HiperM. Unblinded: 1/10-HCC, 1/10- HMG. I-Expert: only 1/10-FNH, 1/10-HCC, 1/10- HMG misdiagnosed. Unblinded: all lesions were correctly diagnosed. II-Expert: 1/10-FNH, 1/10-HCC misdiagnosed. Unblinded: only 1/10-FNH was misdiagnosed. The CAD classifier managed a 75.2% overall correct classification rate. The overall classification before and after the uncovering of clinical data was: I beginner 78 %; 94%, II 82%; 96%. I expert 94%; 100%. II 96%; 98%. CONCLUSIONS The CAD prototype can assist a beginner for a better CEUS diagnostic accuracy. The integration of clinical data in the CAD algorithm is essential. Graphical abstract: Average Intensity variation in Arterial and Late Phase with supra unitary (meaning wash in and sub unitary pattern (meaning washout. REFERENCES 1.Sugimoto K, Shiraishi J, Moriyasu F, Doi K. Computer-aided diagnosis for contrast-enhanced ultrasound in the liver. World J Gastroenterol. 2010;2:215-223. 2. Gatos I, Tsantis S, Spiliopoulos S, Skouroliakou A, Theotokas I

  6. Ultrasonography and cholescintigraphy in the diagnostics of biliary tree

    International Nuclear Information System (INIS)

    Iskrenova, Zh.; Minchev, D.

    1997-01-01

    The purpose is to determine whether a reversed sequence of bile flow (i.e. small bowel followed by gallbladder) could serve as an indicator of chronic cholecystitis. 43 hepatobiliary scans were reviewed retrospectively with attention to the relative order of gallbladder and small bowel appearance during the first hour. Usually radioactive bile flows initially into the gallbladder followed by passage into the small bowel. The scintigraphic findings were correlated with results from gallbladder histopathology and gallbladder ultrasonography in 11 patients. The specificity of a reversed sequence for chronic cholecystitis was 82% using ultrasonography and 100% for histopathology. The visualization of gallbladder after the small bowel appears in patients referred for possible biliary tract disease predicts chronic cholecystitis (author)

  7. Interobserver Variation of the Renal Length Measurement on Ultrasonography

    International Nuclear Information System (INIS)

    Jeong, Yoong Ki; Chung, Hye Weon; Kim, Tae Sung; Ryoo, Jae Wook; Kim, Tae Kyoung; Kim, Seung Hyup

    1995-01-01

    We assessed interobserver variation in the measurement of the renal length on ultrasonography. Ultrasonographic examinations were performed in randomly selected 50 patients. The maximallenhths of both kidneys were measured with calipers during the scanning from frozen images by three observers in a blinded fashion. There was a relatively constant tendency of an observer to measure a renal length either longer or shorter than the other observer(Kendall coefficient>0.05). Average interobserver variations were 0.51 cm (±0.42 cm) in right kidney and 0.53 cm (±0.41 cm) in left kidney and were within 1 cm in 91% right and 89% of left kidney. Interobserver variation about 1cm should be considered in the measurement of the renal length on ultrasonography

  8. On use of ultrasonography in obstetrics and gynecology

    International Nuclear Information System (INIS)

    Woo, Kwang Suk; Lee, Yong Woo

    1984-01-01

    Ultrasonography is playing an very important in diagnosis of normal pregnancy and the other diseases in the fields of obstetrics and gynecology. It is mainly used B-mode and Real time linear scan for pregnancy such as fetal movement during its early stage, fetal position, placenta location and biparietal diameter during its middle stage, and amniotic fluid and placenta previa during its late stage, as well as tumor accompanying pregnancy. Ultrasonography has been extensively used in the fields of obstetrics and gynecology for obtaining detailed images of soft tissues without hazard to the fetus and pregnant woman. In view of the need for its professionalism of high degree of skill, this treatise will introduce clinical instances and images obtained in the sonography room of the Seoul National University Hospital

  9. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  10. Ultrasonography of hydronephrosis and renal masses

    International Nuclear Information System (INIS)

    Lee, Kyung Weon; Kim, Chong Gun; Kim, Yeon Jin; Rhee, Byung Chull

    1984-01-01

    We have analyzed ultrasonographic findings of 55 cases of hydronephrosis and 34 cases of renal masses. The results are as follows: 1. 55 cases of hydronephrosis revealed renal enlargement in 55 cases, separation of central echo complex in 27 cases, multiple anechoic areas radiating from the center in 25 cases and dilated renal pelvis in 24 cases. 2. Among the masses in 34 cases, simple renal cyst were 15 cases, polycystic kidney in 8 cases, hypernephroma in 8 cases, Wilm's tumor in 2 cases and agiomyolipoma in 1 case. 3. Simple renal cyst revealed single in 14 cases (93%) and well defined anechoic mass with posterior enhancement in all cases. 4. Polycystic kidney revealed bilateral irregular shaped renal enlargement and multiple anechoic cysts throughout the kidney. 2 cases (25%) involved liver. 5. 6 cases (75%) of hypernephroma revealed ill defined moderately echogenic mass without posterior enhancement. 6. All cases of Wilm's tumor revealed well defined large mixed echogenic mass in right kidney. 7. Angiomyolipoma revealed bilateral dense echogenic mass with large hemorrhage cyst in right kidney. 8. The ultrasonography is useful noninvasive diagnostic modality of evaluation of renal masses and hydronephrosis.

  11. A case of alcoholic hepatitis demonstrating focal fatty infiltration of the liver on computed tomography

    International Nuclear Information System (INIS)

    Uesaka, Toshihiro; Kato, Masayoshi; Nagai, Tadayuki; Kametani, Tomio; Horigami, Tateyuki; Takimoto, Hiroaki; Tanino, Mikio

    1985-01-01

    Focal fatty infiltration of the liver is a newly recognized entity that may be confused with primary neoplasm or tumor metastasis on computed tomography. We report a 31-year-old woman with a history of chronic alcoholism. Physical examination revealed jaundice, marked hepatomegaly and ascites. Laboratory studies revealed mild elevation of bilirubin, AlP, GOT, γ-GTP and marked leukocytosis. Abdominal CT showed a large area of decreased density in the right lobe. The radionuclide scan demonstrated the area of diminished activity located in the central portion of the right lobe. Ultrasonography demonstrated high echoic mass shadows in the right lobe. The rapid disappearance of the low density area on CT was recognized. The liver biopsy specimen revealed fatty metamorphosis, alcoholic hyaline bodies, pericellular fibrosis and mild lobular disorganization. Focal fatty infiltration can mimic focal hepatic lesions and repeat CT scans are useful in diagnosis. (author)

  12. Preoperative nuclear scans in patients with melanoma

    International Nuclear Information System (INIS)

    Au, F.C.; Maier, W.P.; Malmud, L.S.; Goldman, L.I.; Clark, W.H. Jr.

    1984-01-01

    One hundred forty-one liver scans, 137 brain scans, and 112 bone scans were performed in 192 patients with clinical Stage 1 melanoma. One liver scan was interpreted as abnormal; liver biopsy of that patient showed no metastasis. There were 11 suggestive liver scans; three of the patients with suggestive liver scans had negative liver biopsies. The remaining eight patients were followed from 4 to 6 years and none of those patients developed clinical evidence of hepatic metastases. All of the brain scans were normal. Five patients had suggestive bone scans and none of those patients had manifested symptoms of osseous metastases with a follow-up of 2 to 4.5 years. This study demonstrates that the use of preoperative liver, brain and bone scan in the evaluation of patients with clinical Stage 1 melanoma is virtually unproductive

  13. Ultrasonography of the omasum in 30 Saanen goats

    Directory of Open Access Journals (Sweden)

    Jacquat Désirée

    2011-02-01

    Full Text Available Abstract Background Primary diseases of the omasum are uncommon in goats, although the omasum may be involved in various gastrointestinal disorders. Examination of the caprine omasum via ultrasonography requires a good understanding of the normal appearance of the organ. However, in contrast to cattle, there is a lack of reference information on this topic in goats. Thus, the goal of the present study was to describe the results of ultrasonography of the omasum in 30 healthy Saanen goats. Results Ultrasonography was carried out in standing, non-sedated goats using a 5.0 MHz linear transducer. The location and size of the omasum, thickness of the omasal wall and visualisation of the abomasal laminae, contents and contractions were assessed. The omasum was visible from the 9th intercostal space (ICS in all the goats, and from the 8th and 10th ICSs in 29 and 24 goats, respectively. The omasum was seen medial to the liver, but only the omasal wall closest to the transducer was visible. The dorsal omasal limit formed a dorsally convex curve running from cranioventral to caudodorsal and was furthest from the dorsal midline in the 6th ICS. The ventral omasal limit formed a ventrally convex curve. The size of the omasum was largest (10.2 ± 3.1 cm in the 9th ICS and decreased cranially and caudally from this position. Active omasal motility was recorded in 20 goats with 0.3 to 2.0 contractions per minute. Conclusions The findings of this study provide reference ranges for the interpretation of the location and size of the omasum in goats with suspected omasal abnormalities. Ultrasonography is an ideal diagnostic tool for evaluation of the omasum, which is not accessible to conventional examination techniques, such as inspection, palpation, percussion and auscultation.

  14. Transvaginal ultrasonography in first trimester of pregnancy and its comparison with transabdominal ultrasonography

    Directory of Open Access Journals (Sweden)

    Aneet Kaur

    2011-01-01

    Full Text Available Objectives : Examination of pregnant women in the first trimester with transvaginal ultrasonography with the aim to study various fetal development markers, e.g., gestation sac, yolk sac, fetal heart motion, CRL length, and fetal anatomy in both normal and abnormal pregnancies. Comparative evaluation of transvaginal ultrasonography vis-ΰ-vis transabdominal scanning in the study of first trimester of pregnancy and its complications. To assess the relative merits and demerits of transvaginal ultrasonography in comparison with the transabdominal technique. Materials and Methods : The study will be conducted on 50 females patients during the first trimester of pregnancy. The study population will consist of both normal and abnormal pregnancies. These patients will be included on the basis of suspicion of or proven pregnancy of duration up to 12 weeks from LMP. The evaluation of the patients will include the following: Record of patients obstetrical history and clinical examination, record of pregnancy test and relevant investigations, ultrasonic examination of pregnancy. (a Transabdominal ultrasound scanning will be done with moderately distended bladder by using real time scanners with low frequency probe (3/3.5 MHz; (b transvaginal sonography will be done with the real-time sector scanner using high-frequency endovaginal probe (5/7.5 MHz, after the patient voids urine. Relevant images will be taken by using the multiformat automatic camera. Results and Conclusions : In the study of 46 normal intrauterine pregnancies, TVS showed additional information in 36 patients (78.3% as compared to TAS, in detection of gestation sac, yolk sac, double bleb sign, or better visualization of embryonic anatomy. In the abnormal pregnancy (n=17, TVS provided more information in 11 cases (64.9%, which included detection of embryonic demise, yolk sac, double bleb sign, or subchorionic hemorrhage. Regarding ectopic gestations (n=7, TVS gave additional information in 5

  15. Availability of ultrasonography in health examination of atomic bomb survivors

    International Nuclear Information System (INIS)

    Kato, Masafumi; Mito, Kazuyo; Ishibashi, Shinzo; Takayama, Sadamatsu; Ito, Chikako

    1989-01-01

    A total of 1424 A-bomb survivors, consisting of 596 men and 827 women, participated in the health screening during the period from August 1985 through March 1988. Abnormal findings of ultrasonography were observed in 64% for men and 53% for women. According to age groups, the incidence of abnormal findings tended to increase with aging in men. In women, it was independent of aging. The most common abnormal finding was billiary calculus (13%), followed by renal cyst, splenomegaly, hepatomegaly, and liver disturbance. Suspected hepatic tumor, hepatomegaly, liver disturbance, fatty liver, and liver cirrhosis were more frequent in men than women. The incidence of billiary or gallbladder calculus was significantly higher in women than men. Among 56 survivors (13%) with suspected malignancy, it was confirmed in 25 survivors (19 with primary or metastatic liver carcinoma, 3 with renal cell carcinoma, 2 with cholangiocarcinoma, and one with pancreatic carcinoma). Of 9 hepatoma patients, 8 had an increased alpha-fetoprotein. Hematologic findings were normal in all of the patients with renal cell carcinoma. (N.K.)

  16. The utility of the macro-aggregated albumin lung perfusion scan in the diagnosis and prognosis of hepatopulmonary syndrome in cirrhotic patients candidates for liver transplantation

    Directory of Open Access Journals (Sweden)

    Israel Grilo

    Full Text Available Background: The macro-aggregated albumin lung perfusion scan (99mTc-MAA is a diagnostic method for hepatopulmonary syndrome (HPS. Aim: To determine the sensitivity of 99mTc-MAA in diagnosing HPS, to establish the utility of 99mTc-MAA in determining the influence of HPS on hypoxemia in patients with concomitant pulmonary disease and to determine the correlation between 99mTc-MAA values and other respiratory parameters. Methods: Data from 115 cirrhotic patients who were eligible for liver transplantation (LT were prospectively analyzed. A transthoracic contrast echocardiography and 99mTc-MAA were performed in 85 patients, and 74 patients were diagnosed with HPS. Results: The overall sensitivity of 99mTc-MAA for the diagnosis of HPS was 18.9% (14/74 in all of the HPS cases and 66.7% (4/6 in the severe to very severe cases. In HPS patients who did not have lung disease, the degree of brain uptake of 99mTc-MAA was correlated with the alveolar-arterial oxygen gradient (A-a PO2 (r = 0.32, p < 0.05 and estimated oxygen shunt (r = 0.41, p < 0.05 and inversely correlated with partial pressure of arterial oxygen (PaO2 while breathing 100% O2 (r = -0.43, p < 0.05. The 99mTc-MAA was positive in 20.6% (7/36 of the patients with HPS and lung disease. The brain uptake of 99mTc-MAA was not associated with mortality and normalized in all cases six months after LT. Conclusions: The 99mTc-MAA is a low sensitivity test for the diagnosis of HPS that can be useful in patients who have concomitant lung disease and in severe to very severe cases of HPS. It was not related to mortality, and brain uptake normalized after LT.

  17. International guidelines for contrast-enhanced ultrasonography

    DEFF Research Database (Denmark)

    Nolsøe, Christian Pállson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramati...

  18. Discrimination of individuals in a general population at high-risk for alcoholic and non-alcoholic fatty liver disease based on liver stiffness: a cross section study

    Directory of Open Access Journals (Sweden)

    Kasai Kenji

    2011-06-01

    Full Text Available Abstract Background Factors associated with liver stiffness (LS are unknown and normal reference values for LS have not been established. Individuals at high risk for alcoholic (ALD and non-alcoholic fatty (NAFLD liver disease need to be non-invasively discriminated during routine health checks. Factors related to LS measured using a FibroScan and normal reference values for LS are presented in this report. Methods We measured LS using a FibroScan in 416 consecutive individuals who presented for routine medical checks. We also investigated the relationship between LS and age, body mass index (BMI, liver function (LF, alcohol consumption, and fatty liver determined by ultrasonography. We identified individuals at high-risk for ALD and NAFLD as having a higher LS value than the normal upper limit detected in 171 healthy controls. Results The LS value for all individuals was 4.7 +/- 1.5 kPa (mean +/- SD and LS significantly and positively correlated with BMI and LF test results. The LS was significantly higher among individuals with, than without fatty liver. Liver stiffness in the 171 healthy controls was 4.3 +/- 0.81 kPa and the upper limit of LS in the normal controls was 5.9 kPa. We found that 60 (14.3% of 416 study participants had abnormal LS. The proportion of individuals whose LS values exceeded the normal upper limit was over five-fold higher among those with, than without fatty liver accompanied by abnormal LF test results. Conclusions Liver stiffness could be used to non-invasively monitor the progression of chronic liver diseases and to discriminate individuals at high risk for ALD and NAFLD during routine health assessments.

  19. Diagnosis and treatment of cysts of the liver

    International Nuclear Information System (INIS)

    Al'perovich, B.I.; Mitasov, V.Ya.

    1989-01-01

    Is is shown that ultrasonography, computer tomography, laparoscopy provide for liver cyst detection. Parasitic cyst of Echinococcus and opisthhordeiasis nature are subject to surgical treatment. Selective procedures under echinococcosis include echinococcotomy and liver resection, and under opisthorchiasis - liver resection. Under nonparasitic liver cysts of minor size dynamic observation is advisable, under medium, hard and multiple complication cysts - sergical treatment is advisable. Selective procedures under non-complicated cysts include cyst resection with tamponage using omentum, and under complicated multiple cysts - liver resection

  20. Is ultrasonography essential before surgery in eyes with advanced cataracts?

    Directory of Open Access Journals (Sweden)

    Salman Amjad

    2006-01-01

    Full Text Available Background: Ultrasonography is an important tool for evaluating the posterior segment in eyes with opaque media. Aim: To study the incidence of posterior segment pathology in eyes with advanced cataract and to see whether certain features could be used as predictors for an abnormal posterior segment on ultrasound. Setting: Tertiary care hospital in South India. Methods and Materials: In this prospective study conducted over a 6-month period, all eyes with dense cataracts precluding visualization of fundus underwent assessment with ultrasound. Presence of certain patient and ocular "risk" factors believed to be associated with a higher incidence of abnormal posterior segment on ultrasound were looked for and the odds ratio (OR for posterior segment pathology in these eyes was calculated. Results: Of the 418 eyes assessed, 36 eyes (8.6% had evidence of posterior segment pathology on ultrasound. Retinal detachment (17 eyes; 4.1% was the most frequent abnormality detected. Among patient features, diabetes mellitus (OR= 4.9, P=0.003 and age below 50 years (OR= 15.4, P=0.001 were associated with a high incidence of abnormal ultrasound scans. In ocular features, posterior synechiae (OR= 20.2, P=0.000, iris coloboma (OR= 34.6, P=0.000, inaccurate projection of rays (OR= 15.1, P=0.002, elevated intraocular pressure (OR= 15.1, P=0.004, and keratic precipitates (OR= 22.4, P=0.004 were associated with high incidence of posterior segment pathology. Only four eyes (1.5% without these features had abnormal posterior segment on ultrasonography. Conclusions: Certain patient and ocular features are indicative of a high risk for posterior segment pathology and such patients should be evaluated by ultrasonography prior to cataract surgery. In the absence of these risk factors, the likelihood of detecting abnormalities on preoperative ultrasonography in eyes with advanced cataracts is miniscule.

  1. Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bruyn, George A W; Möller, Ingrid; Garrido, Jesus

    2012-01-01

    To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods.......To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods....

  2. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  3. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    International Nuclear Information System (INIS)

    Arimizu, Noboru

    1980-01-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for vesectable small cancers was investigated by the project team and coworkers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared. (Tsunoda, M.)

  4. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    Energy Technology Data Exchange (ETDEWEB)

    Arimizu, N [Chiba Univ. (Japan). School of Medicine

    1980-06-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for resectable small cancers was investigated by the project team and co-workers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared.

  5. Liver transplant

    Science.gov (United States)

    Hepatic transplant; Transplant - liver; Orthotopic liver transplant; Liver failure - liver transplant; Cirrhosis - liver transplant ... The donated liver may be from: A donor who has recently died and has not had liver injury. This type of ...

  6. Ultrasonography for neuraxial blocks: a review of the evidence.

    Science.gov (United States)

    Elgueta, Maria F; Duong, Silvia; Finlayson, Roderick J; Tran, De Q

    2017-05-01

    This narrative review summarizes the evidence derived from randomized controlled trials (RCTs) pertaining to the use of adjunctive ultrasonography (US) for neuraxial blocks. The literature search was conducted using the MEDLINE, EMBASE and PUBMED databases. For the MEDLINE and EMBASE searches, the MESH terms "ultrasonography" and key word "ultrasound" were queried; using the operator "and", they were combined with the MESH terms "neuraxial block," "epidural anesthesia," "epidural analgesia," "spinal anesthesia," "spinal analgesia," "intrathecal anesthesia," "intrathecal analgesia," "caudal anesthesia," and "caudal analgesia." For the PUBMED search, the search terms "ultrasound neuraxial," "ultrasound intrathecal," "ultrasound epidural" (limited to clinical trials), "ultrasound spinal" (limited to clinical trials), and "ultrasound caudal" (limited to clinical trials) were queried. Seventeen RCTs were retained for analysis. Compared to conventional palpation of landmarks, US assistance (i.e., preprocedural scanning) results in fewer needle passes/insertions and skin punctures for neuraxial blocks in obstetrical and surgical patients. These benefits seem most pronounced when expert operators carry out the sonographic exams and for patients displaying difficult spinal anatomy. Preliminary findings also suggest that US provides similar pain relief and functional improvement to fluoroscopy for epidural/caudal steroid injection in patients afflicted with chronic spinal pain. Although one trial demonstrated shorter needling time with US guidance (i.e., real-time scanning of needle advancement) compared to US assistance, these findings require further validation. Published reports of RCTs provide evidence to formulate limited recommendations regarding the use of adjunctive US for neuraxial blocks. Further well-designed RCTs are warranted.

  7. Preoperative radiological characterization of hepatic angiomyolipoma using magnetic resonance imaging and contrast-enhanced ultrasonography: a case report

    Directory of Open Access Journals (Sweden)

    Schmid Roland M

    2011-09-01

    Full Text Available Abstract Introduction A hepatic angiomyolipoma is a rare benign tumor of the liver composed of a mixture of smooth muscle cells, blood vessels and a variable amount of adipose tissue. Differentiating them from malignant liver tumors can often be very difficult. Case presentation We report the case of a 43-year-old Caucasian man presenting with a large liver mass in the right lobe. The results of magnetic resonance imaging and contrast-enhanced ultrasonography were consistent with a well-demarcated adipose tissue- containing tumor, showing prolonged hyperperfusion in comparison with the surrounding liver tissue. Surgery was performed and the diagnosis of hepatic angiomyolipoma was made with histopathology. Conclusion Preoperative radiological characterization using magnetic resonance imaging and contrast-enhanced ultrasonography may improve diagnostic accuracy of hepatic angiomyolipoma. Identification of smooth muscle cells, blood vessels and adipose tissue with a positive immunohistochemical reaction for HMB-45 is the final evidence for an angiomyolipoma.

  8. [Low grade renal trauma (Part II): diagnostic validity of ultrasonography].

    Science.gov (United States)

    Grill, R; Báca, V; Otcenásek, M; Zátura, F

    2010-04-01

    The aim of the study was to verify whether ultrasonography can be considered a reliable method for the diagnosis of low-grade renal trauma. The group investigated included patients with grade I or grade II blunt renal trauma, as classified by the AAST grading system, in whom ultrasonography alone or in conjunction with computed tomography was used as a primary diagnostic method. B-mode ultrasound with a transabdominal probe working at frequencies of 2.5 to 5.0 MHz was used. Every finding of post-traumatic changes in the renal tissues, i.e., post-contusion hypotonic infiltration of the renal parenchyma or subcapsular haematoma, was included. The results were statistically evaluated by the Chi-square test with the level of significance set at 5%, using Epi Info Version 6 CZ software. The group comprised 112 patients (43 women, 69 men) aged between 17 and 82 years (average, 38 years). It was possible to diagnose grade I or grade II renal injury by ultrasonography in only 60 (54%) of them. The statistical significance of ultrasonography as the only imaging method for the diagnosis of low-grade renal injury was not confirmed (p=0.543) Low-grade renal trauma is a problem from the diagnostic point of view. It usually does not require revision surgery and, if found during repeat surgery for more serious injury of another organ, it usually does not receive attention. Therefore, the macroscopic presentation of grade I and grade II renal injury is poorly understood, nor are their microscopic findings known, because during revision surgery these the traumatised kidneys are not usually removed and their injuries at autopsy on the patients who died of multiple trauma are not recorded either. The results of this study demonstrated that the validity of ultrasonography for the diagnosis of low-grade renal injury is not significant, because this examination can reveal only some of the renal injuries such as perirenal haematoma. An injury to the renal parenchyma is also indicated by

  9. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-02-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt.

  10. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-01-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt. (author)

  11. Direct comparison of the FibroScan XL and M probes for assessment of liver fibrosis in obese and nonobese patients

    Directory of Open Access Journals (Sweden)

    Durango E

    2013-07-01

    Full Text Available Esteban Durango,1,* Christian Dietrich,1,* Helmut Karl Seitz,1 Cornelia Ursula Kunz,2 Gilles T Pomier-Layrargues,3 Andres Duarte-Rojo,4 Melanie Beaton,5 Magdy Elkhashab,6 Robert P Myers,7 Sebastian Mueller1,3 1Department of Medicine and Center for Alcohol Research, Liver Disease and Nutrition, Salem Medical Center, 2Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany; 3Liver Unit, Centre Hospitalier de l'Université de Montréal, Hôpital Saint-Luc, Montréal, Quebec, 4Toronto Western Hospital Liver Centre, Toronto, Ontario; 5Multi-Organ Transplant Unit, University of Western Ontario, London, Ontario; 6The Toronto Liver Centre, Toronto, Ontario; 7Liver Unit, Division of Gastroenterology and Hepatology, Department of Medicine, University of Calgary, Calgary, Alberta, Canada *These authors contributed equally to this researchBackground: A novel Fibroscan XL probe has recently been introduced and validated for obese patients, and has a diagnostic accuracy comparable with that of the standard M probe. The aim of this study was to analyze and understand the differences between these two probes in nonobese patients, to identify underlying causes for these differences, and to develop a practical algorithm to translate results for the XL probe to those for the M probe.Methods and results: Both probes were directly compared first in copolymer phantoms of varying stiffness (4.8, 11, and 40 kPa and then in 371 obese and nonobese patients (body mass index, range 17.2–72.4 from German (n = 129 and Canadian (n = 242 centers. Liver stiffness values for both probes correlated better in phantoms than in patients (r = 0.98 versus 0.82, P 10 kPa for F0, F1–2, F3, and F4 fibrosis, respectively significantly improved agreement between the two probes from r = 0.655 to 0.679.Conclusion: Liver stiffness can be measured in significantly more obese and nonobese patients using the XL probe than the M probe. However, the XL

  12. Acoustic radiation force impulse elastography, FibroScan®, Forns’ index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods

    Science.gov (United States)

    DONG, DAO-RAN; HAO, MEI-NA; LI, CHENG; PENG, ZE; LIU, XIA; WANG, GUI-PING; MA, AN-LIN

    2015-01-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns’ index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty-one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal-Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal-Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=−0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of these

  13. Clinical characteristics associated with hepatic steatosis on ultrasonography in patients with elevated alanine aminotransferase

    Directory of Open Access Journals (Sweden)

    Janaína Luz Narciso-Schiavon

    Full Text Available CONTEXT AND OBJECTIVE: The main causes of hepatic steatosis (HS are alcoholic liver disease and nonalcoholic fatty liver disease (NAFLD. Although liver biopsy is the gold standard for NAFLD diagnosis, the finding of abnormal aminotransferases in abstinent individuals, without known liver disease, suggests the diagnosis of NAFLD in 80-90% of the cases. Identification of clinical factors associated with HS on abdominal ultrasound may enable diagnoses of fatty liver non-invasively and cost-effectively. The aim here was to identify clinical variables associated with HS in individuals with elevated alanine aminotransferase (ALT levels. DESIGN AND SETTING: Cross-sectional study in a single tertiary care center. METHODS: Individuals with elevated ALT, serologically negative for hepatitis B and C, were evaluated by reviewing medical files. Patients who did not undergo abdominal ultrasonography were excluded. RESULTS: Among 94 individuals included, 40% presented HS on ultrasonography. Compared with individuals without HS, those with fatty liver were older (P = 0.043, with higher body mass index (BMI (P = 0.003, diabetes prevalence (P = 0.024, fasting glucose levels (P = 0.001 and triglycerides (P = 0.003. Multivariate analysis showed that BMI (odds ratio, OR = 1.186; 95% confidence interval, CI: 1.049-1.341; P = 0.006 and diabetes mellitus (OR = 12.721; 95% CI: 1.380-117.247; P = 0.025 were independently associated with HS. CONCLUSIONS: Simple clinical findings such as history of diabetes and high BMI may predict the presence of HS on ultrasonography in individuals with elevated ALT and negative serological tests for hepatitis.

  14. Cholangiocarcinoma in Magnetic Resonance Cholangiopancreatography and Fascioliasis in Endoscopic Ultrasonography

    Directory of Open Access Journals (Sweden)

    Amir Houshang Mohammad Alizadeh

    2011-10-01

    Full Text Available Fascioliasis is a worldwide zoonotic infection with Fasciola hepatica and Fasciola gigantica. The zoonoses are particularly endemic in sheep-raising countries and are also endemic in Iran. Typical symptoms that may be associated with fascioliasis can be divided by phases of the disease, including the acute or liver phase, the chronic or biliary phase, and ectopic or pharyngeal fascioliasis. Cholestatic symptoms may be absent, and in some cases diagnosis and treatment may be preceded by a long period of abdominal pain, eosinophilia and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 4 years, with imaging suggesting cholangiocarcinoma. Considering a new concept of endoscopic ultrasonography, at last F. hepatica was extracted with endoscopic retrograde cholangiography.

  15. An audit of ultrasonography performed and reported by trainee radiologists.

    Science.gov (United States)

    Eze, K C; Marchie, T T; Eze, C U

    2009-01-01

    Proforma information, instructions and procedures of training in radiology are lacking in Nigeria. To describe the errors in ultrasonography performed by unsupervised trainee radiologists. The radiology records of all ultrasound scans (USS) carried out and all reports that came back to the unit of the authors on account of misdiagnosis, doubtful diagnosis, misinformation or error in the reports were studied. The patients with the returned reports were rescanned where available by consultants and the collected data analysed. A total of 4680 patients had ultrasound studies without supervision resulting in 605 (12.93%) queried reports. The USS scans of 235 (5.02%) patients were repeated with consultants in attendance resulting in significant change in reports of 95 (2.03%) patients. Analysis of the request cards of 605 queried reports showed omission of relevant clinical information 463 (76.53%), outright wrong information 65 (10.73%),and unconventional abbreviations 139 (22.98%), while 493 (81.49%) were completed by a nurse, medical student or junior resident. Typographical errors comprised 174 (28.76%) of the 605 queried reports. False negative error was the highest type of error seen in 55 (57.89%) of the 95 patients with significant change in their report after repeat scan as lesions not detected were not documented. Trainee radiologists make significant errors in carrying out and reporting ultrasonography without adequate direct supervision of the study by their training consultants. Majority of the errors originate from lack of accurate filling of the patients request cards by the requesting physicians, lack of adequate preparation for the intended study, and typographical errors in writing reports. False negative reports are by far the greatest cause of errors recorded as lesions not detected were not documented.

  16. Ultrasonography of the scrotum in adults

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Anna L.; Scotegagna, Eduardo; Nowitaki, Kristina M.; Kim, Young M. [Dept. of UMass Memorial Medical Center, University of Massachusetts Medical Center, Worcester (United States)

    2016-07-15

    Ultrasonography is the ideal noninvasive imaging modality for evaluation of scrotal abnormalities. It is capable of differentiating the most important etiologies of acute scrotal pain and swelling, including epididymitis and testicular torsion, and is the imaging modality of choice in acute scrotal trauma. In patients presenting with palpable abnormality or scrotal swelling, ultrasonography can detect, locate, and characterize both intratesticular and extratesticular masses and other abnormalities. A 12-17 MHz high frequency linear array transducer provides excellent anatomic detail of the testicles and surrounding structures. In addition, vascular perfusion can be easily assessed using color and spectral Doppler analysis. In most cases of scrotal disease, the combination of clinical history, physical examination, and information obtained with ultrasonography is sufficient for diagnostic decision-making. This review covers the normal scrotal anatomy as well as various testicular and scrotal lesions.

  17. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  18. Scintigraphy and ultrasonography of various thyroid diseases

    International Nuclear Information System (INIS)

    Ban, Yoshio; Nagakura, Hozumi; Kawauchi, Akihiro; Fukunari, Nobuhiro; Itoh, Kunihiko; Higashi, Tomomitsu.

    1987-01-01

    We reported the usefulness of scintigraphy and ultrasonography of various thyroid diseases. The scintigraphy were useful information in the determination of functioning adenoma, location of ectopic thyroid glands and appearance of lang and bone metastasis of thyroid carcinoma. As ultrasonography were able to be observation of internal structure of thyroid gland, that maight be used to determined associated nodular lesions in diffuse goiter and differentiation between benign and malignant tumor in nodular goiter. In observation of calcifications of goiter, soft X rays apparatus were usefull tool. US, as initial diagnostic test before scintiscanning, provided useful information and minimized radiation exposure. (author)

  19. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  20. Transabdominal Ultrasonography of the Small Bowel

    Directory of Open Access Journals (Sweden)

    Rudolf Kralik

    2013-01-01

    Full Text Available In the era of double balloon enteroscopy, capsule endoscopy, CT, and MRI enterography is transabdominal ultrasonography (TUS underestimated method for evaluation of small bowel pathology. As often initial imagine method in abdominal complaints, nowadays has TUS much better diagnostic potential than two decades ago. High-resolution ultrasound probes with harmonic imaging significantly improve resolution of bowel wall in real time, with possibility to asses bowel peristalsis. Color flow doppler enables evaluation of intramural bowel vascularisation, pulse wave doppler helps to quantificate flow in coeliac and superior mesenteric arteries. Small intestine contrast ultrasonography with oral contrast fluid, as well as contrast enhanced ultrasonography with intravenous microbubble contrast also improves small bowel imaging. We present a review of small intestine pathology that should be detected during ultrasound examinations, discuss technical requirements, advantages and limitations of TUS, typical ultrasound signs of Crohn's disease, ileus, celiac disease, intussusception, infectious enteritis, tumours, ischemic and haemorrhagic conditions of small bowel. In the hands of experienced investigator, despite some significant limitations(obesity, meteorism, is transabdominal ultrasonography reliable, noninvasive and inexpensive alternative method to computerised tomography (CT and magnetic resonance imaging (MRI in small bowel examination.

  1. Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography

    OpenAIRE

    Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide

    2016-01-01

    Backgraound An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the useful...

  2. Liver Transplant

    Science.gov (United States)

    ... Liver Function Tests Clinical Trials Liver Transplant FAQs Medical Terminology Diseases of the Liver Alagille Syndrome Alcohol-Related ... the Liver The Progression of Liver Disease FAQs Medical Terminology HOW YOU CAN HELP Sponsorship Ways to Give ...

  3. Pattern of abnormal ultrasonographic findings in patients with clinical suspicion of chronic liver disease in Sokoto and its environs

    Directory of Open Access Journals (Sweden)

    Sadisu Mohammrd Ma`aji

    2013-06-01

    Full Text Available Objective: To analyse the various abnormal transabdominal ultrasound findings in patients with clinical suspicion of chronic liver disease in our environment with a view of comparing our findings with other existing literatures. Methods: A total of 61 consecutive patients with clinical signs and symptoms of chronic liver disease attending medical outpatient clinic at the Department of Medicine, Usmanu Danfodiyo University, Teaching Hospital Sokoto and Federal Medical Centre Birnin Kebbi were scanned at Radiology Departments for any abnormal intraabdominal findings from May 2011 to April 2012. All the patients were scanned with Apogee 800 plus (Japan 2002 and Concept D (Dynamic Imaging Scotland Ultrasound scanners with a variable frequency probes at 5-12 MHz. Results: A total of 61 abdominal ultrasounds were performed during this study period. All the cases met the inclusion criteria. The mean age was (46.0依12.6 years (ranged 50 years. The mean liver size was (13.25依1.48 cm (ranged 11 cm and (14.00依0.77 cm (ranged 0.77 cm for right and left lobe respectively. The mean spleen size was (15.90依1.22 cm (ranged 6 cm. The sex distribution was males 43 (70.49% and females 18 (29.5%. Of the 61 cases included, the indication for the abdominal ultrasonography were hepatitis 1 (1.6%, liver cirrhosis 20 (50.82%, obstructive jaundice 2 (3.28%, chronic liver disease 25 (40.98% and chronic abdominal swelling 2 (3.2%. Conclusions: In conclusion, our study has demonstrated various abnormal transabdominal ultrasound findings in patients suspected with chronic liver disease in our locality. Ultrasound is useful in the diagnosis of chronic liver disease in daily clinical practice. However, the sensitivity can be improved if a high frequency probe is used and done by experienced and dedicated operators. Liver biopsy remains the gold standard especially when patients are clinically asymptomatic.

  4. Prevalence and sonographic changes compatible with fatty liver disease in patients referred for abdominal ultrasound examination in Aracaju, SE

    Directory of Open Access Journals (Sweden)

    Josilda Ferreira Cruz

    2016-02-01

    Full Text Available Abstract Objective: To estimate the prevalence and evaluate sonographic findings compatible with changes consistent with hepatic steatosis in patients referred for abdominal ultrasonography at four reference centers in Aracaju, SE, Brazil. Materials and Methods: Prospective, descriptive survey, with analytical and quantitative approach, comprising abdominal ultrasonography scans performed with a convex, dynamic 3.75 MHz transducer. Liver dimensions and parenchymal echotexture were evaluated, classifying hepatic steatosis into grades (1, 2 or 3. The SPSS® 22.0 software was used for statistical analysis, adopting p < 0.05 as significance level. Results: A total of 800 individuals (561 women and 239 men were evaluated. The prevalence of steatosis was 29.1%, and the male patients were most affected, presenting with more advanced grades of disease (p = 0.021, as follows: 119 grade 1 (51.0%; 94 grade 2 (40.4%; and 20 grade 3 (8.6%. The median age patients' was 46 years. Conclusion: In the present study sample, the prevalence of hepatic steatosis was high, particularly in the male patients. Ultrasonography is suggested as a first choice for the diagnosis of this condition, considering its wide availability, low cost and absence of side effects or risks to the patient.

  5. Preoperation diagnosis of stomach neoplasm metases in the liver

    International Nuclear Information System (INIS)

    Fisher, M.E.; Zholnerovich, E.M.; Zelenkevich, A.S.

    1988-01-01

    It is shown that application of ultrasonography and computerized tomography in examining the upper part of abdomen in patients with stomach neoplasm permits to judge on metastases into the liver. Application of invasive methods of examination is indicated only in case of indefinite data of ultrasonography and computerized tomography. It is shown that application of invasive methods isn't advisable in patients with stomach neoplasm to which palliative operations are indicated. 4 refs

  6. Adaptive sound speed correction for abdominal ultrasonography: preliminary results

    Science.gov (United States)

    Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo

    2013-03-01

    Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.

  7. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    Science.gov (United States)

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  8. Evaluation of real time ultrasonography of the normal pancreas

    International Nuclear Information System (INIS)

    Kim, H. K.; Ko, Y. T.; Kim, S. Y.; Ahn, C. Y.

    1981-01-01

    91 cases who were free of pancreatic disease and the related conditions, were studied by high resolution and wide field real time ultrasonographic scanner with 3.5 MHz linear array electronically focusing transducers. The pancreatic examination method and the anatomic structures in and around the pancreas were investigated, and the normal pancreatic findings by real time ultrasonography were as follows: 1. Among all 91 cases, 44 cases were male and 47 cases female, and the frequent age groups were the 4th to the sixth decade. 2. The pancreatic images were obtained in 86% and the good images in 65%. 3. The shapes of pancreas were sausage (40%), dumb-bell (34%), tadpole (9%), and club (17%). 4. Pancreatic size was 1.56 ± 0.37, 2.4, 0.8 cm (Mean ± SD, Max., Min.) in head, 1.32 ± 0.29, 2.0, 0.8 cm in isthmus, and 1.62 ± 0.31, 2.4, 1.0 cm in tail. 5. The successful rate of pancreatic duct visualization was 46%. The shapes of pancreatic duct were linear (22%), tramline (16%), and tubular (8%). 6. The pancreatic echogenecity is greater than that of the liver in 68%, and equivalent to that of the liver in 32%, and no normal pancreas displayed less echogenecity than the liver. 7. Pancreatic echogenecity is lesser than that of adjacent soft tissue in 79% and equivalent to that of adjacent soft tissue in 21%. 8. The pancreatic echogenecity is homogenous in 79%. 9. The pancreatic margin is smooth in 62%, undulated in 11%, and ill defined in 27%

  9. Liver Scanning with Colloidal Radiogold; Exploration du foie a l'aide de l'or radioactif colloidal; Issledovanie pecheni pri pomoshchi radioaktivnogo kolloidal'nogo zolota; Exploracion del higado con oro coloidal radiactivo

    Energy Technology Data Exchange (ETDEWEB)

    Donato, L; Becchini, M F; Panichi, S [Centro di Medicina Nucleate, University of Pisa (Italy)

    1959-07-01

    The authors report their experience in the use of colloidal Au{sup 198} for liver scanning. To obtain a good differentiation of liver from surrounding organs and tissues, a tracer dose of 2.5 {mu}C/kg is usually required. The whole scanning procedure, starting 30 minutes after intravenous injection, takes about 90 minutes, when carried out with fully automatic equipment. Upper and lateral liver contours are usually better defined than the lower one; the use of focusing collimators (honeycomb type) increases the resolution remarkably. In normal conditions the liver is the only organ clearly evident on the scan; the spleen may also become evident in some cases of splenomegaly and liver cirrhosis, probably on account of the reduction of reticuloendothelial system of the liver. In the experience of the authors, the efficiency of the technique is very poor for the detection of liver metastases of small size, not inducing changes of the volume and shape of the liver. In fact, uncertain results have been obtained even in cases of micronodular metastatic diffusion, confirmed at operation. The Au{sup 198} scanning may be of help in cases with diffuse or zonal enlargement, whatever the origin, in order to establish whether the changes are due to enlargement of normally functioning tissue, or to the presence of intrahepatic pathologic entities. It has been found very helpful to combine liver scanning with x-ray examination of liver contours after carrying out a pneumoperitoneum, in order to compare anatomical and functional patterns. Scintigraphs and x-ray contours are normally superimposable, and the finding of significant discrepancies may be helpful in evaluating the possibility of surgical or radiation treatment in patients with tumours, especially of the gastrointestinal tract. Of course, a negative result will not rule out the possibility of liver metastases. Original scintigraphs and corresponding x-ray films are presented, and the results of major interest are

  10. Role of autoimmunity in nonviral chronic liver disease.

    Science.gov (United States)

    Amarapurkar, D N; Amarapurkar, A D

    2000-11-01

    To evaluate the prevalence and clinical profile of autoimmune hepatitis (AIH) in patients with chronic liver disease. Four hundred and thirty five consecutive patient with chronic liver disease seen in our department from January 1997 to December 1998 were studied with detailed history and clinical examination. All the patients underwent liver function tests, ultrasonography, isotope liver scanning, viral markers, autoimmune markers ANA, ASMA, LKM1 and AMA (by immunofluorescence technique) and liver histology whenever permissible. Appropriate work up for Wilson's disease was done whenever suspected clinically. Diagnosis of autoimmune hepatitis was made by the composite scoring system by international autoimmune hepatitis group. Twenty out of the 435 patients met the criteria of definite autoimmune hepatitis and seven patient had probable autoimmune hepatitis. Forty out of 408 patients showed markers of autoimmunity positive but did not qualify diagnosis of AIH on composite scores. Demographic profile of 27 patients with autoimmune hepatitis was as follows; male:female ratio 1:8, mean age 39.8 +/- 13 years (Range 4-65 years); mode of presentation as cirrhosis 11/27 (40.7%), chronic hepatitis 12/27 (44.4%) and acute hepatitis 4/27 (14.8%). Elevated serum bilirubin levels were seen in 12 (44.4%) patients while mean serum aminotransferases levels were 249 +/- 343 and 262 +/- 418 respectively. Other disease associations seen were as follows: diabetes in 4 (14.8%), rheumatoid arthritis in 3 (11%), hypothyroidism in 2 (7.4%) and ulcerative colitis in 1 (3.7%). The pattern of autoimmune markers was ANA +ve 23/27 (85%) (+ve titres of ANA > 1:80 in adults and 1:20 in children), ASMA +ve in 16/27 (59.2%) (+ve titres of ASMA > 1:40) and LKM1 in 3 patients. AMA in tires less than 1:80 was found in 3 patients. Liver histology changes seen were lymphoplasmacytic infiltrates (100%), bridging necrosis (93%), liver cell rossetting (80%) and fibrosis with or without cirrhosis (50

  11. Non-real-time computed tomography-guided percutaneous ethanol injection therapy for heapocellular carcinoma undetectable by ultrasonography

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    1998-01-01

    The purpose of this study was to evaluate the feasibility of non-real-time CT-guided percutaneous ethanol injection therapy (PEIT) for hepatocellular carcinoma (HCC, 37 lesions) untreatable by ultrasonography-guided (US)-PEIT. The HCC lesion was localized on the lipiodol CT image with a graduated grid system. We advanced a 21 G or 22 G needle in a stepwise fashion with intermittent localization scans using a tandem method to position the tip of the needle in the lesion. Ethanol containing contrast medium was injected with monitoring scans obtained after incremental volumes of injection, until perfusion of the lesion was judged to be complete. A total of 44 CT-PEIT procedures were performed. The average number of needle passes from the skin to the liver in each CT-PEIT procedure was 2.3, the average amount of ethanol injected was 14.4 ml, and the average time required was 49.3 minutes. Complete perfusion of the lesion by ethanol on monitoring CT images was achieved in all lesions with only a single or double CT-PEIT procedure without severe complication. Local recurrence was detected only in 5 lesions. At present, it is more time-consuming to perform CT-PEIT than US-PEIT because conventional CT guidance is not real-time imaging. However, it is expected that this limitation of CT-PEIT will be overcome in the near future with the introduction of CT fluoroscopy. In conclusion, CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC undetectable by US. (author)

  12. Duplex Ultrasonography Has Limited Utility in Detection of Postoperative DVT After Primary Total Joint Arthroplasty.

    Science.gov (United States)

    Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick

    2016-07-01

    Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a

  13. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  14. Ultrasonography in Early Diagnosis of Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Shan-Hui Lin

    2014-12-01

    Full Text Available We report here the case of a 32-year-old man with a history of traumatic brain injury who presented with swelling of his right thigh. Soft tissue ultrasonography performed 3 days after the onset of symptoms showed a heterogeneous hyperechoic lesion with the formation of cysts and hypervascularity in the right iliopsoas abutting the surface of the femoral bone. This became a diffuse echogenic plaque with a posterior acoustic shadowing 12 days later. A diagnosis of heterotopic ossification was made on the basis of the presence of typical ultrasonographic findings and was confirmed by pathology. We emphasize that an early diagnosis of heterotopic ossification can be made with ultrasonography and can lead to early treatment.

  15. Acoustic radiation force impulse elastography of the liver. Can fat deposition in the liver affect the measurement of liver stiffness?

    International Nuclear Information System (INIS)

    Motosugi, Utaroh; Ichikawa, Tomoaki; Araki, Tsutomu; Niitsuma, Yoshibumi

    2011-01-01

    The aim of this study was to compare acoustic radiation force impulse (ARFI) results between livers with and without fat deposition. We studied 200 consecutive healthy individuals who underwent health checkups at our institution. The subjects were divided into three groups according to the echogenicity of the liver on ultrasonography (US) and the liver-spleen attenuation ratio index (LSR) on computed tomography: normal liver group (n=121, no evidence of bright liver on US and LSR >1); fatty liver group (n=46, bright liver on US and LSR 5 days a week (n=18) were excluded from the analysis. The velocities measured by ARFI in the normal and fatty liver groups were compared using the two one-sided test. The mean (SD) velocity measured in the normal and fatty liver groups were 1.03 (0.12) m/s and 1.02 (0.12) m/s, respectively. The ARFI results of the fatty liver group were similar to those of the normal liver group (P<0.0001). This study suggested that fat deposition in the liver does not affect the liver stiffness measurement determined by ARFI. (author)

  16. Vascular access: the impact of ultrasonography

    Science.gov (United States)

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  17. Differential diagnosis of calf pain by ultrasonography

    Directory of Open Access Journals (Sweden)

    Luciano Augusto Botter

    2008-03-01

    Full Text Available This paper aims to evaluate the recent and numerous applications of ultrasonography in the differential diagnosis of conditions that affect the popliteal fossa and lower limbs, resulting in calf pain. Popliteal cysts and their ruptures, aneurysms, hematomas, cellulitis, abscesses, soft tissue tumors and other fluid collections are easily identified by this technique. Moreover, post-trauma and inflammatory conditions affecting muscles and tendons, muscle necrosis, deep venous thrombosis and superficial thrombophlebitis are very well demonstrated by the ultrasonographic screening.

  18. The utility of repeat sestamibi scans in patients with primary hyperparathyroidism after an initial negative scan.

    Science.gov (United States)

    Krishnamurthy, Vikram D; Sound, Sara; Okoh, Alexis K; Yazici, Pinar; Yigitbas, Hakan; Neumann, Donald; Doshi, Krupa; Berber, Eren

    2017-06-01

    We analyzed the utility of repeated sestambi scans in patients with primary hyperparathyroidism and its effects on operative referral. We carried out a retrospective review of patients with primary hyperparathyroidism who underwent repeated sestambi scans exclusively within our health system between 1996-2015. Patient demographic, presentation, laboratory, imaging, operative, and pathologic data were reviewed. Univariate analysis with JMP Pro v12 was used to identify factors associated with conversion from an initial negative to a subsequent positive scan. After exclusion criteria (including reoperations), we identified 49 patients in whom 59% (n = 29) of subsequent scans remained negative and 41% (n = 20) converted to positive. Factors associated with an initial negative to a subsequent positive scan included classic presentation and second scans with iodine subtraction (P = .04). Nonsurgeons were less likely to order an iodine-subtraction scan (P < .05). Fewer patients with negative imaging were referred to surgery (33% vs 100%, P = .005), and median time to operation after the first negative scan was 25 months (range 1.4-119). Surgeon-performed ultrasonography had greater sensitivity and positive predictive value than repeated sestamibi scans. Negative sestambi scans decreased and delayed operative referral. Consequently, we identified several process improvement initiatives, including education regarding superior institutional imaging. Combining all findings, we created an algorithm for evaluating patients with primary hyperparathyroidism after initially negative sestamibi scans, which incorporates surgeon-performed ultrasonography. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Real time ultrasonography in obstructive jaundice

    International Nuclear Information System (INIS)

    Cho, Kyung Sik; Kim, Ho Kyun; Sung, Nak Kwan; Kim, Soon Yong

    1982-01-01

    Ultrasonography is a predominantly accurate, relatively simple unique diagnostic method of obstructive jaundice. The ultrasonographic findings of obstructive jaundice are dilated intra- and extrahepatic duct with intraluminal hyper reflective echo or mass in and/ or around the bile duct. The superiority of high resolution real time ultrasonography for the diagnosis of obstructive jaundice is bases on the easy detectability of extra- and intrahepatic bile ducts by its multiple sectional images in a short time, the flexibility of probe and small crystal size. Author evaluated real time sonographic findings 46 obstructive jaundice patients confirmed by surgery or radiographical examinations. The results were: 1. Diameter of extrahepatic duct in obstructive jaundice were varied from normal to 4.0 Cm, mostly 8 to 10 mm in diameter (26%). Degree of dilatation of biliary duct appeared more prominent in cancer patients than other causes of obstruction. 2. The site of obstruction was detected in 85% (39/46) and its common site was common bile duct in 63% (29/46). 3. The diagnostic accuracy of choledocholithiasis and cancer was 82% (22/27) and 44% (4/9), respectively. Diagnostic accuracy of the real time ultrasonography in obstructive jaundice was over all 75% (34/46)

  20. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  1. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    International Nuclear Information System (INIS)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju

    2014-01-01

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  2. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju [Dept. of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  3. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  4. Ultrasonography of pleural effusion. The quantification of minimal detectable volume

    International Nuclear Information System (INIS)

    Sustic, A.; Medved, I.; Ekl, D.; Simic, O.; Kovac, D.; Ivanis, N.

    2001-01-01

    Background. The aim of this study was to establish a minimal volume of free thoracic fluid in the pleural space of the supine cadaver detectable by ultrasonography. Material and methods. A prospective study with an experimental model on 20 cadavers (10 male, 10 female; age 66 ±11 yr.; height 172 ±9 cm; weight 75 ±12.6 kg; body surface area (BSA) 1.87 ±0.2 m 2 ) was used. Each cadaver was punctured bilaterally in 5 th or 6 th intercostal space at the medioclavicular line with venous cannula infusing in NaCl 0,9% solution at randomised speed in the chest. During the procedure the laterodorsal part of the thoracic wall next to the pulmonal base and phrenicocostal sinus was ultrasonographically scanned. At the moment of the visualisation of anechogenic line pertaining to the free fluid between dorsal thoracic wall and lungs, the installation was stopped and the amount of injected fluid verified. Results. Minimal, by ultrasonography detectable amount of free fluid in the right pleural space was 223±52 ml with the significant positive correlation to height (r = 0.69; p < 0.001), weight (r 0.68; p < 0.01) and the BSA (r = 0.71; p < 0.001) of cadaver. Detectable volume in the left pleural space was notably smaller than contra lateral, namely 172±53 ml also with a significant correlation to the cadaver's height (r = 0.55; p < 0.05), weight (r = 0.59; p < 0.01) and BSA (r = 0.60; p < 0.01). Conclusions. The authors affirm that ultrasonographically detectable quantity of free fluid in the chest positively correlates with height, weight and BSA of cadavers, and that the measured amount in the supine position is approximately 223 ml for the right space versus 172 ml for the left pleural space. (author)

  5. Utility of Ultrasonography for Urinary Tract Infections of Infants

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chul Ho; Kim, Yun Jeong [Dongnam Health Univ., Seoul (Korea, Republic of)

    2009-06-15

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), {sup 99m}TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and {sup 99m}TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  6. Utility of Ultrasonography for Urinary Tract Infections of Infants

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Kim, Yun Jeong

    2009-01-01

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), 99m TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and 99m TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  7. Congenital abdominal dumbbell fashion neuroblastoma with invasion of spinal canal detected by ultrasonography - case report

    International Nuclear Information System (INIS)

    Kosiak, W.; Czarniak, P.; Swieton, D.; Piskunowicz, M.; Drozynska, E.; Szolkiewicz, A.

    2007-01-01

    A case of congenital abdominal dumbbell fashion neuroblastoma with invasion of the spinal canal detected by ultrasonography (US) is presented. A 3-week-old male neonate was admitted to the hospital with a palpable mass in the left lumbar region. Ultrasound examination was performed on the same day. It disclosed a pathologic mass filling the left side of the retroperitoneal space - displacing laterally and inferiorly the left kidney. The second part of the tumor was located above the Gerot's fascia in the muscles and infiltrated the tomography scanning confirmed the presence of solid masses in these locations. Urinary excretion of vanillin-mandelic acid (VMA) was within normal range, ferritin level was elevated (447 μg/ml). Bone scintigraphy showed metastases to the left clavicle. There were no changes in bone marrow. Diagnosis of an undifferentiated malignant neuroblastoma was established in histopathological examination. Spinal ultrasonography is highly recommended in neonates and infants with retroperitoneal tumors. (author)

  8. Spiral CT findings of inflammatory pseudotumor of the liver

    International Nuclear Information System (INIS)

    Lee, Ha Jong; Nam, Kyung Jin; Lee, Ki Nam; Park, Byeong Ho; Choi, Jong Cheol; Koo, Bong Sik; Nam, Ki Dong; Kim, Chan Seong

    1998-01-01

    To assess the spiral CT findings of inflammatory pseudotumor of the liver(IPTL), in order to distinguish this tumor from hepatocellular carcinoma, hepatic abscess or other space occupying liver lesions. The spiral CT findings of IPTL were retrospectively evaluated in six patients. All cases were confirmed by ultrasonography-guided gun biopsy. Four patients were men and two were women, and they were aged between 37 and 74 (mean, 49) years. The site, size, and number of IPTL were assessed, and their enhancement patterns were evaluated during the arterial, portal and delayed phases of spiral CT. Five cases involved a solitary mass and in one there were multiple masses with surrounding small nodules. Four cases occurred in the right lobe and two in the left lobe. Four of five surrounding nodules were in the left lobe. During the arterial phase of spiral CT scanning, three layers were separated from four of five cases of solitary mass;they were composed of central and peripheral portions of low attenuation, and an intermediate portion of isoattenuation. Delayed enhancement of the peripheral portion was prominent during the delayed phase. In the case involving multiple masses three layers were not seen during the arterial phase, but during the delayed phase enhancement was noted. The features of three layers, as seen on spiral CT, is considered to be very specific for distinguishing IPTL from other hepatic focal lesions.=20

  9. The Place of Ultrasonography in the Evaluation of Rib Fractures

    OpenAIRE

    Fulya Bakılan; Gökhan Yüce; Ahmet Çağdaş Biçen; Tanju Keten

    2015-01-01

    Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was...

  10. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  11. APPLICATION OF LAPAROSCOPIC ULTRASONOGRAPHY IN ADNEXAL OPERATIONS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective:To explore the clinical value on application of laparoscopic ultrasonography (Lap US) in the adnexal operation. Methods:Eleven patients including 7 cases of tubal pregnancy, 3 cases of teratoma of ovary and 1 case of endometrial cyst of ovary were examined by LapUS, then operated with laparoscopy.Results:The results showed that the modality presented is a big progress over the traditional operative management for adnexal diseas. Conclusions:It is a good approach for micro-surgery in the adnexal operation by laparoscopy.

  12. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients.

    Science.gov (United States)

    Vafaei, Ali; Hatamabadi, Hamid Reza; Heidary, Kamran; Alimohammadi, Hosein; Tarbiyat, Mohammad

    2016-01-01

    Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT) scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67), were enrolled (77.6% male). Chest CT scan showed pulmonary contusion in 48 (31.6%) patients, hemothorax in 29 (19.1%), and pneumothorax in 55 (36.2%) cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96), 0.86 (95% CI: 0.78‒0.94), and 0.80 (95% CI: 0.736‒0.88), respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87) for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86) for hemothorax, and 0.58 (95% CI: 0.5‒0.67) for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02) and pulmonary contusion (p < 0.001). However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08). The results of the present study showed that ultrasonography is preferable to radiography in the initial evaluation of patients with traumatic injuries to the

  13. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients

    Directory of Open Access Journals (Sweden)

    Ali Vafaei

    2016-01-01

    Full Text Available Introduction: Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. Methods: In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. Results: 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67, were enrolled (77.6% male. Chest CT scan showed pulmonary contusion in 48 (31.6% patients, hemothorax in 29 (19.1%, and pneumothorax in 55 (36.2% cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96, 0.86 (95% CI: 0.78‒0.94, and 0.80 (95% CI: 0.736‒0.88, respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87 for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86 for hemothorax, and 0.58 (95% CI: 0.5‒0.67 for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02 and pulmonary contusion (p < 0.001. However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08. Conclusion: The results of the present study showed that ultrasonography is preferable to radiography in the initial

  14. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    International Nuclear Information System (INIS)

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guang Qing; Cui, Xiao Jing; Liang, Xian

    2016-01-01

    The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501) and 94.2% (389/413), respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177) vs. liver without fat infiltration (389/413) (P=0.277); mild fatty liver (162/177) vs. moderate fatty liver (190/212) (P=0.604); mild fatty liver (162/177) vs. severe fatty liver (83/112) (P<0.001); moderate fatty liver (190/212) vs. liver without fat infiltration (389/413) (P=0.051); moderate fatty liver (190/212) vs. severe fatty liver (83/112) (P<0.001); severe fatty liver (83/112) vs. liver without fat infiltration (389/413) (P<0.001); and fatty liver (435/501) vs. liver without fat infiltration (389/413) (P<0.001). Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis

  15. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guang Qing; Cui, Xiao Jing; Liang, Xian [Affiliated Hospital of Hainan Medical College, Haikou (China)

    2016-01-15

    The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501) and 94.2% (389/413), respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177) vs. liver without fat infiltration (389/413) (P=0.277); mild fatty liver (162/177) vs. moderate fatty liver (190/212) (P=0.604); mild fatty liver (162/177) vs. severe fatty liver (83/112) (P<0.001); moderate fatty liver (190/212) vs. liver without fat infiltration (389/413) (P=0.051); moderate fatty liver (190/212) vs. severe fatty liver (83/112) (P<0.001); severe fatty liver (83/112) vs. liver without fat infiltration (389/413) (P<0.001); and fatty liver (435/501) vs. liver without fat infiltration (389/413) (P<0.001). Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis.

  16. Renal scan

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  17. Atlas of liver imaging

    International Nuclear Information System (INIS)

    1989-05-01

    This atlas is an outcome of an IAEA co-ordinated research programme. In addition to Japan, nine other Asian countries participated in the project and 293 liver scintigrams (116 from Japanese institutions and 177 from seven Asian countries) were evaluated by physicians from the participating Asian countries. The computer analysis of the scan findings of the individual physicians was carried out and individual scores have been separately tabulated for: (a) scan abnormality; (b) space occupying lesions; (c) cirrhosis and (d) diffuse liver diseases like hepatitis. Refs, figs and tabs

  18. Liver Hemangioma

    Science.gov (United States)

    Liver hemangioma Overview A liver hemangioma (he-man-jee-O-muh) is a noncancerous (benign) mass in the liver. A liver hemangioma is made up of a tangle of blood vessels. Other terms for a liver hemangioma are hepatic hemangioma and cavernous hemangioma. Most ...

  19. Intraoperative ultrasonography in nine dogs with intra-abdominal neoplasm suspect

    Directory of Open Access Journals (Sweden)

    Daniella Matos da Silva

    Full Text Available ABSTRACT: Intraoperative ultrasonography (IOUS is used in medicine for diagnosis and guidance during oncologic surgery. The aims of this study were to assess the performance, feasibility, advantages and difficulties of the IOUS technique in dogs with suspected intra-abdominal tumors. The study included nine client-owed dogs that had suspected intra-abdominal tumors (spleen, liver or bowel based on transabdominal ultrasound examination and that were subsequently referred for exploratory laparotomy surgery. During surgery, IOUS was performed; results of preoperative transabdominal ultrasonography, inspection by the surgeon and IOUS were compared on a case-by-case basis. IOUS was helpful in determining lesion resection in all cases. Lesions detected solely by the use of IOUS were observed in seven out of nine cases. Analysis of these cases demonstrated that IOUS can be a tool to assist during oncology surgery on the liver, spleen or bowel. Dogs with hepatic tumors can have small non-palpable intraparenchymal nodules, which may be visible by IOUS.

  20. Radionuclide scan findings in delayed splenic rupture

    International Nuclear Information System (INIS)

    Flickinger, F.W.; Jackson, G.L.

    1978-01-01

    An initial liver/spleen scan performed on a patient with blunt abdominal trauma was negative 3 days following the accident. A follow-up scan 7 days later showed definite evidence of splenic rupture, proved surgically. The authors conclude that, in such cases, spleen scans may be negative initially because of delayed splenic ruptures

  1. Diagnostic value of ultrasonography in evaluation and management ...

    African Journals Online (AJOL)

    Results: Common causes of acute abdominal emergencies in pediatric patients as noted on ultrasonography included nonspecifi c pain (28%), abdominal abscess (21%), acute appendicitis (7%) and intussusception (7%). Ultrasonography was diagnostic in 45.2% cases and supportive in 12.3% of the cases. As for as the fi ...

  2. Nuclear medicine and ultrasonography in the acute cholecystitis diagnosis

    International Nuclear Information System (INIS)

    Schmillevitch, J.; Serson, D.; Camera, A.J.; Oliveira Nunes, J.E. de; Bazzo, J.M.B.

    1980-01-01

    Newer modalities for the evaluation of gallbladder include cholescintigraphy and ultrasonography. The IDA-Tc 99m presents functional informations with regard to cystic duct patency. The ultrasonography demonstrates the topographic anatomy of gallbladder, and morfologic alterations. Both analysis are preconized in acute cholecystitis. (Author) [pt

  3. Transabdominal color doppler ultrasonography: A relevant approach for assessment of effects of uterine torsion in buffaloes

    Directory of Open Access Journals (Sweden)

    Devender

    2016-08-01

    Full Text Available Aim: The present study was conducted on advanced pregnant buffaloes suffering from uterine torsion to assess the status of fetus and uterus by transabdominal ultrasonography, and the findings were compared with normal advanced pregnant buffaloes. Materials and Methods: The study was conducted on 20 clinical cases of uterine torsion and 20 normal advanced pregnant buffaloes (control group. The lower ventral area just lateral to linea alba (on both sides of the udder in standing animals was scanned transabdominally by the two-dimensional convex transducer for various ultrasonographic findings. The data collected were statistically analyzed by “one-way ANOVA” and “independent sample t-test” using computerized SPSS 16.0 software program. Results: Transabdominal ultrasonography revealed dead fetus in 95% uterine torsion cases and proved useful in imaging internal structures of fetuses while no dead fetus was reported in the control group. Size of umbilicus was found significantly decreased (p0.05 in uterine torsion group. Average thickness of the uterine wall and mean pixel values of fetal fluids (echogenicity were found significantly increased (p<0.05 in uterine torsion affected buffaloes in comparison to control group. Conclusion: Status of fetus (whether live or dead, internal status of uterus, and its contents could be determined by transabdominal ultrasonography in uterine torsion cases and thus determining the prognosis of the uterine torsion cases before going for further manipulations. This will also help in taking all the precautions to avoid death of the fetus.

  4. Applications of Ultrasonography in Female Lower Urinary Tract Symptoms: Diagnosis and Intervention

    Directory of Open Access Journals (Sweden)

    Wen-Chen Huang

    2004-09-01

    Full Text Available Lower urinary tract symptoms (LUTS are a common health problem causing considerable inconvenience to many women. Moreover, they are non-specific and can be caused by a large number of disorders. A thorough evaluation, including physical examination, imaging studies, and urodynamic investigation of the lower urinary tract, is crucial for appropriate management of bothersome symptoms. Ultrasonography has the advantages of non-invasiveness, reproducibility, no radiation exposure, and low cost. With the use of a high-resolution transducer, pelvic organs can be demonstrated clearly on ultrasonography. In addition, three-dimensional sonography provides a clear demonstration of the spatial orientation of the female lower urinary tract. Both color and power Doppler scanning can not only reveal the vascular flow in pelvic organs, but also demonstrate urinary flow. Ultrasonography has dual functions in the management of female LUTS: diagnosis and intervention. It may help physicians to recognize the anatomic characteristics of specific pelvic floor disorders, to explore the pathophysiologic mechanism responsible for pelvic floor dysfunction, and to assist in the surgical management of LUTS with minimal invasion. Since female LUTS may originate from gynecologic or nongynecologic conditions, it is more convenient and helpful to obtain transvaginal and introital sonograms at the same time by using an endovaginal probe.

  5. ULTRASONOGRAPHIC EVALUATION OF AMOEBIC LIVER ABSCESS

    Directory of Open Access Journals (Sweden)

    Nagesh

    2016-04-01

    Full Text Available AIMS To study the role of ultrasonography in the diagnosis, followup, resolution and percutaneous interventions of amoebic liver abscesses. METHODOLOGY 25 patients with 38 amoebic liver abscesses were included in this study. The diagnostic criteria being compatible history, tender and enlarged liver, radiological and ultrasound findings and response to metronidazole therapy. Confirmed cases of amoebic liver abscesses were followed up by ultrasonography till complete resolution. RESULTS The highest incidence of age was seen between 3 rd and 5 th decades (84% with a male sex incidence of 92%, disease preponderance in people belonging to low socioeconomic group and a high incidence among alcoholics. The radiological findings were: Elevation of right dome of diaphragm (56%, restricted diaphragmatic movements (88%, right basal lung changes (48%, right pleural effusion (12%, and indistinct hazy diaphragmatic contour (40%. The ultrasonographic findings were: 87% of the abscesses were located in right lobe, 11% in left lobe and 2% in both lobes. Among the 25 patients, 76% showed solitary and 24% showed multiple abscesses. Of the 38 amoebic abscesses, 79% were hypoechoic, 13% were hyperechoic and 8% were anechoic. 11 patients were subjected for ultrasound-guided aspiration. CONCLUSION Ultrasound is a safe, reliable and non-invasive imaging modality for the diagnosis, followup and percutaneous interventions of amoebic liver abscesses. The sonographic resolution time of amoebic liver abscesses varies from 28 to 286 days.

  6. The Place of Ultrasonography in the Evaluation of Rib Fractures

    Directory of Open Access Journals (Sweden)

    Fulya Bakılan

    2015-12-01

    Full Text Available Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was proposed as the diagnostic criteria for detecting the rib fracture. Results: Rib fracture was detected in 20 patients (62.5% according to ultrasonography results. A mildly displaced fracture was detected in 7 patients (35%, hematoma was detected in 3 patients (15% and multiple fractures (in 5th, 6th, 7th, and 8th ribs were detected in 1 patient (5%. Conclusion: The results of our study showed that ultrasonography is superior to chest x-ray, in detecting rib fractures.

  7. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  8. Bladder volume variations of cervical cancer patient in radiation therapy using ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Jong Ho [Dept. of Radiation Oncology, Pusan National University Hospital, Pusan (Korea, Republic of)

    2016-12-15

    The bladder volume change was measured using ultrasonography for helping decrease the side effects and other organ variations in the location of radiation therapy for cervical cancer patients. An experiment was performed targeting patients who were treated with radiation therapy at PNUH within the period from September to December 2015. To maintain the bladder volume, each patient was instructed to drink 500 cc water before and after CT simulation, 60 minutes before the dry run. Also, the bladder volume was measured in each patient CT scan, and a 3D conformal therapy plan was designed. The bladder volumes measured before and after the CT simulation, dry run, and radiation treatment planning were compared and analyzed. The average volume and average error of the bladder that were obtained from the measurement based on the CT scan images had the lowest standard deviation in the CT simulation. This means that the values that were obtained before and after the CT simulation were statistically relevant and correlative. Moreover, the bladder volume measured via ultrasonography was larger size, the average volume in the CT scan. But the values that were obtained Dry run and after the CT simulation were not statistically relevant. Drinking a certain amount of water helps a patient maintain his/her bladder volume for a dry run. Even then, it is difficult to maintain the bladder volume for the dry run. Also, whether or not the patients followed the directions for the dry run correctly is important.

  9. Are oblique views necessary for detecting space occupying lesions in liver scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Seki, Hiroyasu; Taki, Junichi; Yokoyama, Kunihiko; Tada, Akira

    1983-01-01

    In colloid scanning of the liver to determine the presence or absence of SOL(s), it has been suggested that oblique views are desirable. However, it is not popular in Japan to obtain oblique views in routine liver imgaing. The present study was conducted to determine whether such additional views are necessary or not. Liver images of 20 patients with SOL(s) and 84 patients without SOL, all of which were confirmed by ultrasonography, transmission computed tomography and/or clinical course, were evaluated initially using 4 standard views and then adding oblique views by 6 physicians (3 experts and 3 freshmen in nuclear medicine). The numbers of cases showing different interpretation between 4 views and 6 views were 15, 10 and 13 each when interpreted by 3 experts. However, those were 21, 33 and 18 each when interpreted by 3 freshmen. Sensitivity for detecting SOL was improved in 3 physicians by adding oblique views, but was the same in other 3. Specificity was improved in only one physicinan. Overall accuracy was consequently improved in 4 physicians and was deteriorated in 2 physicians. ROC analysis revealed that in the freshman group more accurate interpretation was attained by using 6 views, but in the expert group false-positive cases were increased by using 6 views. Some cases showing usefulness for detecting SOL were presented. In conclusion, oblique views gave more accurate interpretation in inexpertienced observers, and useful information in some cases. (author)

  10. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of)

    2016-05-15

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method.

  11. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    International Nuclear Information System (INIS)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok; Park, Mi Hyun

    2016-01-01

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method

  12. Introital ultrasonography in female urinary incontinence

    Energy Technology Data Exchange (ETDEWEB)

    Weon, Young Cheol; Cho, Kyoung Sik; Lee, Jin Seong; Choi, Sang Hee; Kim, Keon Seok; Choo, Myung Soo [Ulsan Univ. Asan Medical Center, Seoul (Korea, Republic of)

    1996-06-01

    To evaluate the usefulness of introital ultrasonography in the assessment of female urinary incontinence. Introital ultrasonography was performed in fifteen with stress urinary incontinence(mean age 50) and six patients without symptoms of incontinence(mean age 37). Using a sagittal section of the anterior pelvis in the plane of the symphysis pubis the posterior urethrovesical angle, the pubourethral distance and the pubo-yregrak abgle were measured at rest and during stress(Valsalva's maneuver state). The student T-test and the ANOVA test were used in statistical analysis. The posterior urethrovesical angles of the controls were 125.3 deg ({+-}10.9) at rest and 125.7 deg ({+-}7.6) during stress. In the patients, the corresponding angles were 135.3 deg ({+-}11.3) and 139.6 deg({+-}10.8). The posterior urethrovesical angles increased 0.3 deg ({+-}4.7) in the controls and 5.6 deg ({+-}4.0) in the patients(p=0.018). In the controls, the pubo-urethral distances were 21.8 mm({+-}5.8) at rest and 18.2 mm({+-}7.1) during stress, while in the patients these distances were 18.4 mm({+-}3.9) and 12.6 mm({+-}4.4). The pubo-urethral distance decreased 3.5 mm ({+-}1.5) in the controls and 5.8 mm ({+-}2.3) in the patients(p=0.039). In the patients with mild incontinence(Grade I), the posterior urethrovesical angles increased 3.4 deg ({+-}2.8) : 132.3 deg ({+-}12.5) at rest and 135.6 deg (12.8) during stress. In the patients with moderate incontinence(Grade II), the angles increased 8.1 deg({+-}3.8) : 136.0 deg({+-}6.5) at rest and 144.1 deg({+-}5.9) during stress. The change of the posterior urethrovesical angle was related to the grade of urinary incontinence in the patients(p<0.05). There was no statistical significancy in the pubo-urethral angle (p=0.315). Introital ultrasonography may be useful for assessment of stress urinary incontinence.

  13. Portal venous perfusion steal causing graft dysfunction after orthotopic liver transplantation: serial imaging findings in a successfully treated patient

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Su; Chung, Yong Eun; Choi, Jin Young; Park, Mi Suk; Lim, Joon Seok; Kim, Myeong Jin; Kim, Hon Soul [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Sang Kyun [Dept. of Pathology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-01-15

    A 53-year-old male with hepatocellular carcinoma underwent orthotopic liver transplantation. Preoperative computed tomography revealed main portal vein luminal narrowing by flat thrombi and the development of cavernous transformation. On post-transplantation day 1, thrombotic portal venous occlusion occurred, and emergency thrombectomy was performed. Subsequent Doppler ultrasonography and contrast-enhanced ultrasonography confirmed the restoration of normal portal venous flow. The next day, however, decreased portal venous velocity was observed via Doppler ultrasonography, and serum liver enzymes and bilirubin levels remained persistently elevated. Direct portography identified massive perfusion steal through prominent splenorenal collateral veins. Stent insertion and balloon angioplasty of the portal vein were performed, and subsequent Doppler ultrasonography demonstrated normalized portal flow parameters. Afterwards, the serum liver enzymes and bilirubin levels rapidly normalized.

  14. Serum parameters predict the severity of ultrasonographicifndingsinnon-alcoholic fatty liver disease

    Institute of Scientific and Technical Information of China (English)

    Mohsen Razavizade; Raika Jamali; Abbas Arj; Hamidreza Talari

    2012-01-01

    BACKGROUND: Controversy exists about the correlation between liver ultrasonography and serum parameters for evaluating the severity of liver involvement in non-alcoholic fatty liver disease (NAFLD). This study was designed to determine the association between liver ultrasonography staging in NAFLD and serum parameters correlated with disease severity in previous studies; and set optimal cut-off points for those serum parameters correlated with NAFLD staging at ultrasonography, in order to differentiate ultrasonographic groups (USGs). METHODS: This cross-sectional study evaluated outpatients with evidence of NAFLD in ultrasonography referred to a general hospital. Those with positive viral markers, abnormal serum ceruloplasmin or gamma-globulin concentrations were excluded. A radiologist performed the ultrasonography staging and stratiifed the patients into mild, moderate, and severe groups. Fasting serum alanine aminotransferase (ALT), aspartate aminotransferase, alkaline phosphatase, triglyceride (TG), high and low density lipoprotein (HDL, LDL), and cholesterol were checked. RESULTS:Two hundred and forty-ifve patients with a mean age (±standard deviation) of 41.63(±11.46) years were included. There were no signiifcant differences when mean laboratory concentrations were compared between moderate and severe USGs. Therefore, these groups were combined to create revised USGs ("mild"versus"moderate or severe"). There were associations between the revised USGs, and ALT, TG, HDL levels, and diabetes mellitus [odds ratios=2.81 (95%conifdence interval (CI):1.37-5.76), 2.48 (95%CI:1.29-4.78), 0.36 (95%CI:0.18-0.74), and 5.65 (95%CI:2.86-11.16) respectively;all P values CONCLUSIONS: Serum ALT, TG, and HDL concentrations seem to be associated with the staging by liver ultrasonography in NAFLD. They might be used to predict the staging of liver ultrasonography in these patients.

  15. A case report with Weber-Christian disease which recognized interesting abdominal lesions by abdominal ultrasonography and computerized tomography

    International Nuclear Information System (INIS)

    Ishizuka, Jin; Chiba, Junko; Ota, Kei; Mori, Kazuo; Toyota, Takayoshi; Goto, Yoshio

    1984-01-01

    A 59-year-old woman who had Weber-Christian disease associated with typical histological findings such as panniculitis was reported. The patient had painful subcutaneous nodules as the first symptom. She had diabetes mellitus and rheumatoid arthritis, which are reported to be rare complications of this disease. Abdominal ultrasonography and CT scanning revealed various sized cystic lesions and masses in the tail of pancreas. These findings have not yet been reported and seems to be rare in this disease. (Namekawa, K.)

  16. Emphysematous liver abscess in diabetic patient: two cases report

    International Nuclear Information System (INIS)

    Rhim, Hyun Chul; Koo, Ja Hong; Kim, Sung Tae; Kim, Yong Soo; Koh, Byung Hee; Cho, On Koo

    1995-01-01

    There has not been any report on massive air-containing liver abscess in diabetic patients, although emphysematous cholecystitis or pyelonephritis is a well-known complication in them. Authors report two cases of emphysematous liver abscess in diabetic patient, which showed typical findings of massive air-containing hepatic abscess on ultrasonography and computed tomography, but very poor prognosis in spite of immediate and successful percutaneous drainage procedure

  17. Comprehensive ultrasound assessment of complications post-liver transplantation.

    LENUS (Irish Health Repository)

    O'Brien, J

    2010-04-01

    Human liver transplantation for end-stage liver disease was first performed in 1963. Refinements in surgical technique and new immunosuppressive regimens have improved outcomes. Today, transplant patients have a 5-year survival rate of approximately 75%. Nevertheless, significant complications still occur. Ultrasonography (US), is the initial imaging modality of choice allowing bedside assessment for detection and follow-up of early and delayed graft complications, and facilitating interventional procedures. This review outlines the role of ultrasound in post-transplantation assessment.

  18. Current status of ultrasonography of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seun Ah; Kim, Baek Hyun [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Kim, Seon Jeong [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Ji Na [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Park, Sun Young [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of); Choi, Kyung Hee [Incheon Baek Hospital, Incheon (Korea, Republic of)

    2016-03-15

    The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect); flexor tendon tears, trigger finger, and volar plate injuries (volar aspect); gamekeeper’s thumb (Stener lesions) and other collateral ligament tears (lateral aspect); and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  19. Shoulder Ultrasonography: Performance and Common Findings

    Directory of Open Access Journals (Sweden)

    Diana Gaitini

    2012-01-01

    Full Text Available Ultrasound (US of the shoulder is the most commonly requested examination in musculoskeletal US diagnosis. Sports injuries and degenerative and inflammatory processes are the main sources of shoulder pain and functional limitations. Because of its availability, low cost, dynamic examination process, absence of radiation exposure, and ease of patient compliance, US is the preferred mode for shoulder imaging over other, more sophisticated, and expensive methods. Operator dependence is the main disadvantage of US examinations. Use of high range equipment with high resolution transducers, adhering to a strict examination protocol, good knowledge of normal anatomy and pathological processes and an awareness of common pitfalls are essential for the optimal performance and interpretation of shoulder US. This article addresses examination techniques, the normal sonographic appearance of tendons, bursae and joints, and the main pathological conditions found in shoulder ultrasonography.

  20. Current status of automated breast ultrasonography

    Directory of Open Access Journals (Sweden)

    Hee Jung Shin

    2015-07-01

    Full Text Available Breast ultrasonography (US is currently considered the first-line examination in the detection Epub ahead of print and characterization of breast lesions. However, conventional handheld US (HHUS has several limitations such as operator dependence and the requirement of a considerable amount of radiologist time for whole-breast US. Automated breast US (ABUS, recently approved by the United States Food and Drug Administration for screening purposes, has several advantages over HHUS, such as higher reproducibility, less operator dependence, and less required physician time for image acquisition. In addition, ABUS provides both a coronal view and a relatively large field of view. Recent studies have reported that ABUS is promising in US screening for women with dense breasts and can potentially replace handheld second-look US in a preoperative setting.

  1. Current status of ultrasonography of the finger

    Directory of Open Access Journals (Sweden)

    Seun Ah Lee

    2016-04-01

    Full Text Available The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect; flexor tendon tears, trigger finger, and volar plate injuries (volar aspect; gamekeeper’s thumb (Stener lesions and other collateral ligament tears (lateral aspect; and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  2. Scanning with Au198 in experimental hepatic trauma

    International Nuclear Information System (INIS)

    Faifer, J.G.; Macedo, A.R. de; Vicentini, M.L.M.; Hossne, W.S.

    1977-01-01

    Scintiscanning of the liver with Au 198 was performed in 30 mongrel dogs, with the purpose of evaluating the importance of this method in the diagnostic of liver traumatisms. In 18 animals the scanning was performed after 3 differents types of hepatic trauma: intraparenchymal hematoma, stab wound and lasceration of liver. In 12 dogs without hepatic trauma the scanning was performed with the purpose of establishing the pattern of the normal liver scan in the dog. Results indicate that scintiscanning of the liver is a good propaedeutic method in the evaluation of the presence and localization of traumatic hepatic lesion [pt

  3. Focal changes of the spleen in one case of Gaucher disease - assessed by ultrasonography, CT, MRI and angiography

    International Nuclear Information System (INIS)

    Aspestrand, F.; Charania, B.; Scheel, B.; Kolmannskog, F.; Jacobsen, M.

    1989-01-01

    Focal lesions of the spleen in one case of Gaucher disease are demonstrated by ultrasonography, CT, MRI and angiography. The sonographic and angiographic features differ from the findings presented in previous reports. The Gaucher manifestations in the spleen as demonstrated by CT, do not seem to have been reported previously. An earlier report on the MR findings in the liver and spleen in this disease did not disclose any focal abnormalities. In this case, ultrasonography and MRI revealed a targetlike configuration of the focal lesions. An attempt is made to analyze the more complex patterns disclosed by MRI against the background of the manifestations by the other imaging modalities and previous reports. (orig.) [de

  4. Quantitative Assessment of Hepatic Fibrosis by Contrast-enhanced Ultrasonography

    Institute of Scientific and Technical Information of China (English)

    Ming-bo Zhang; En-ze Qu; Ji-Bin Liu; Jin-rui Wang

    2011-01-01

    Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis.Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009.The patients were classified into 5 groups (S0-S4) according to fibrosis stage evaluated with ultrasound guided liver biopsy.New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venons phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group.Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β) were also analyzed.Results Qp/Qa and Ip/Ia decreased from So to S4,while Tp and β increased These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001).Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S1,75% and 86% for groups ≥ S2,71% and 84% for groups ≥ S3,and 76% and 80% for group S4,respectively.Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S1,80% and 76% for groups ≥ S2,74% and 70% for groups ≥ S3,and 81% and 95% for group S4,respectively.Conclusion Ip/Ia and Qp/Qa could be adopted as reliable,non-invasive features for quantitative assessment of hepatic fibrosis.

  5. Cooperative scans

    NARCIS (Netherlands)

    M. Zukowski (Marcin); P.A. Boncz (Peter); M.L. Kersten (Martin)

    2004-01-01

    textabstractData mining, information retrieval and other application areas exhibit a query load with multiple concurrent queries touching a large fraction of a relation. This leads to individual query plans based on a table scan or large index scan. The implementation of this access path in most

  6. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    Science.gov (United States)

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression

  7. Two cases of schistosomiasis japonica diagnosed on computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Seki, Tatsuo; Midorikawa, Shigeo; Hagiri, Masumi; Itoh, Haruhisa; Haku, Eijitsu (Teikyo Univ., Tokyo (Japan). Faculty of Medicine)

    1982-12-01

    We reported two cases of schistosomiasis japonica which showed pathognomonic pattern on liver C.T. and ultrasonography. Schistosomiasis japonica is an endemic disease in areas of Japan, but only chronic case of the disease is found now since Schistosoma Japonicum is thought to be died out in Japan. The adult worms are most commonly in branches of portal system, such as superior mesenteric vein, and many eggs are carried to the liver, where they cause inflammatory pseudotubercle formation, periportal fibrosis, and calcifications in interlobular connective tissue. According to Nakayama et al, pathognomonic pattern of schistosomiasis japonica on U.S. for the liver consists of the amounts of the eggs' calcifications, that is, the more eggs' calcifications, the more pathognomonic U.S. finding. Typical sonographic finding in the liver is network or fishscale pattern, which consists of streaky high level echo and internal low level echo. C.T. similarly demonstrates mosaic high density streak resulting from eggs' calcifications in peripheral portal branches. In addition, if patient's past history shows the life in the endemic area such as these two cases, we can easily make a diagnosis of ''schistosomiasis japonica''.

  8. Two cases of schistosomiasis japonica diagnosed on computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Seki, Tatsuo; Midorikawa, Shigeo; Hagiri, Masumi; Itoh, Haruhisa; Haku, Eijitsu

    1982-01-01

    We reported two cases of schistosomiasis japonica which showed pathognomonic pattern on liver C.T. and ultrasonography. Schistosomiasis japonica is an endemic disease in areas of Japan, but only chronic case of the disease is found now since Schistosoma Japonicum is thought to be died out in Japan. The adult worms are most commonly in branches of portal system, such as superior mesenteric vein, and many eggs are carried to the liver, where they cause inflammatory pseudotubercle formation, periportal fibrosis, and calcifications in interlobular connective tissue. According to Nakayama et al, pathognomonic pattern of schistosomiasis japonica on U.S. for the liver consists of the amounts of the eggs' calcifications, that is, the more eggs' calcifications, the more pathognomonic U.S. finding. Typical sonographic finding in the liver is network or fishscale pattern, which consists of streaky high level echo and internal low level echo. C.T. similarly demonstrates mosaic high density streak resulting from eggs' calcifications in peripheral portal branches. In addition, if patient's past history shows the life in the endemic area such as ours two cases, we can easily make a diagnosis of ''schistosomiasis japonica''

  9. Effects of elastase on fatty liver

    International Nuclear Information System (INIS)

    Ogura, Kazuo; Shimizu, Yoshikazu; Hihara, Masafumi; Ando, Hideki; Nishiyama, Masateru; Tano, Hironobu

    1984-01-01

    Elastase (Elaszym 6T) was administered, in addition to the dietary instruction, to three patients with fatty liver. CT scanning revealed marked improvement in fatty liver. Transaminase levels returned to normal, total cholesterol levels tended to decrease, and HDL-cholesterol levels tended to increase. These results suggest that elastase is effective in the treatment of fatty liver. (Namekawa, K.)

  10. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  11. Candida (Torulopsis glabrata) liver abscesses eight years after orthotopic liver transplantation.

    Science.gov (United States)

    Annunziata, G M; Blackstone, M; Hart, J; Piper, J; Baker, A L

    1997-04-01

    The authors report the case of a 48-year-old man in whom candida (Torulopsis glabrata) liver abscesses developed 8 years after liver transplantation. After a week of fever, computed tomography and Doppler ultrasonography showed several fluid-filled loculations in the left lobe of the liver and hepatic arterial stenosis. Aspirates from the abscesses contained T. glabrata organisms. This complication probably developed because hepatic arterial stenosis resulted in bile infarcts (bilomas), which were contaminated via the biliary tract with candida from the biliary-enteric anastomosis. Catheter drainage and administration of amphotericin B for 10 weeks permitted successful retransplantation. T. glabrata liver abscesses, a life threatening complication that can occur long after liver transplantation, can be successfully managed by aggressive medical treatment followed by retransplantation.

  12. Transrectal contrast-enhanced ultrasonography, transrectal ultrasonography and retrograde cystography for the detection of vesicourethral anastomosis leakage after radical retropubic prostatectomy: a prospective comparative evaluation.

    Science.gov (United States)

    Cantiello, Francesco; Cicione, Antonio; Autorino, Riccardo; De Nunzio, Cosimo; Tubaro, Andrea; Damiano, Rocco

    2013-01-01

    To evaluate the diagnostic accuracy of cystography (CG), transrectal ultrasonography (TRUS) and transrectal contrast-enhanced ultrasonography (CEUS) for the detection of vesicourethral extravasation (VE) after radical retropubic prostatectomy (RRP). In 80 consecutive patients who underwent RRP, the strength of the vesicourethral anastomosis (VUA) was assessed by CG, TRUS and transrectal CEUS. The investigation started with a conventional CG evaluated by an experienced uroradiologist. Following this, patients underwent TRUS which was performed by an experienced urologist who was blinded to the CG findings. The examination started with a conventional B-scan and, subsequently, a CEUS was performed by emptying and refilling the bladder with 90 ml of NaCl 0.9% + 10 ml suspension of 1:10 SonoVue and NaCl 0.9%. 26 patients (32.5%) presented urinary VE and 54 (67.5%) a watertight VUA. In 16 patients (61%) we observed a small leakage, 9 patients (35%) presented a moderate VE, and a large VE was detected in 1 patient (4%). No statistically significant difference in detection of VE was found among the three tests (p = 0.472). TRUS and CEUS are able to provide information about the integrity of the VUA that is comparable with that of CG. Copyright © 2013 S. Karger AG, Basel.

  13. Guide book mammary glands ultrasonography. A textbook according to the DEGUM and KBV guidelines. 3. upd. ed.

    International Nuclear Information System (INIS)

    Madjar, Helmut

    2012-01-01

    The text book on the ultrasonography of mammary glands is based on the concept of a three-step course system. The large amount of pathological indications is supposed to communicate knowledge that is required to find an adequate diagnosis based on ultrasonsographic imaging. The book includes the following chapters: Basics of ultrasonic mammography; diagnostic techniques; sono-anatomy of breast and axilla; standardized diagnosis; mastopathy; cysts and intracystic tumors; prostheses; abscesses; benign solid tumors; scars; carcinomas; lymph nodes; interventional sonography; preoperative staging; preventive diagnostics; aftercare, relapses; 3D-sonography, panorama-scan, real-time compound-scan; CARI technique; Doppler sonography; elastography; examination questions on ultrasonic mammography.

  14. Comparative study of Graves' ophthalmopathy by ultrasonography, computed tomography, and fish bioassay

    International Nuclear Information System (INIS)

    Mann, K.; Schoener, W.; Juengst, D.; Karl, H.J.; Maier-Hauff, K.; Rothe, R.

    1979-01-01

    In 35 patients with Graves' ophthalmopathy (GO) thyroid function was tested by T 3 -RIA, T 4 -RIA, TBI, TRH-test, thyroid scanning, and determination of thyroid autoantibodies. Additional ultrasonography (A-scan), computed tomography (CT) of the orbit, and the determination of an exophthalmogenic serum activity in fish bioassay was performed. Typical alterations for GO were observed in 26 cases with ultrasonography. CT showed an enlargement of medial and/or lateral rectus muscles in 24 of 33 patients, and in 17 cases a region of high density in the apex of the muscle cone. The density of retrobulbar fat after i.v. injection of contrast medium did not differ significantly from that observed in normal men. Characteristic signs of GO were not detected in only 2 cases using both methods together. Exophthalmogenic serum activity was found in the IgG fraction of serum protein. The incidence rate was high (69%), but for diagnostic purpose the fish bioassay cannot be recommended. (orig.) 891 AJ/orig. 892 BRE [de

  15. Endoscopic Ultrasonography in the Diagnosis of Gastric Subepithelial Lesions

    Directory of Open Access Journals (Sweden)

    Eun Jeong Gong

    2016-09-01

    Full Text Available Subepithelial lesions occasionally found in the stomach of patients undergoing endoscopy may be either benign lesions or tumors with malignant potential. They may also appear due to extrinsic compression. Discrimination of gastric subepithelial lesions begins with meticulous endoscopic examination for size, shape, color, mobility, consistency, and appearance of the overlying mucosa. Accurate diagnosis can be achieved with endoscopic ultrasonography, which provides useful information on the exact size, layer-of-origin, and characteristic morphologic features to support a definitive diagnosis. Endoscopic ultrasonography also aids in the prediction of malignant potential, especially in gastrointestinal stromal tumors. Features of subepithelial lesions identified on endoscopic ultrasonography can be used to determine whether further diagnostic procedures such as endoscopic resection, fine needle aspiration, or core biopsy are required. Endoscopic ultrasonography is a valuable tool for diagnosis and clinical decision making during follow-up of gastric subepithelial lesions.

  16. Normal values for quantitative muscle ultrasonography in adults.

    NARCIS (Netherlands)

    Arts, I.M.P.; Pillen, S.; Schelhaas, H.J.; Overeem, S.; Zwarts, M.J.

    2010-01-01

    Ultrasonography can detect structural muscle changes caused by neuromuscular disease. Quantitative analysis is the preferred method to determine if ultrasound findings are within normal limits, but normative data are incomplete. The purpose of this study was to provide normative muscle

  17. Ultrasonography as a diagnostic method in addition to mammography

    Energy Technology Data Exchange (ETDEWEB)

    Otto, H.; Roer, E.

    1988-05-01

    By using ultrasonography in addition to mammography, experienced diagnosticians essentially enhance the safety of their diagnosis of mammary gland diseases. The same applies to gynecomastia, the condition after plastic surgery, and mastitis.

  18. The effect of TACE with endostatin on hemodynamics in hepatic implantation tumor using Doppler ultrasonography

    International Nuclear Information System (INIS)

    Zhou Guangli; Wu Yuanyuan; Wang Bin; Liu Yan; Zheng Chuanli; Sang Li; Liu Feng

    2009-01-01

    Objective: To investigate the hemodynamic changes in the rabbit liver and VX2 hepatic implantation tumor after treatment by transcatheter arterial chemoembolization (TACE)/endostatin using Doppler ultrasonography. Methods: Twenty rabbits with VX2 hepatic tumor were randomly distributed into the control group (n=10) and the anti- angiogenesis group (n=10). The rabbits were administered with endostatin and adriamycin-lipiodol in the anti-angiogenesis group and with 37℃ saline in the control group via hepatic artery. The hemodynamic changes of the tumors, hepatic artery, and portal vein were recorded with Doppler ultrasonography 1 week after the treatment. The results before and after the treatment were compared. Results: In the control group, the maximal hepatic artery blood flow velocity was significantly higher than that before the treatment (P<0.05). However, the resistance index and the portal vein blood flow velocities had no significantly change compared with those before the treatment (P>0.05). In the anti-angiogenesis group, the hepatic artery blood flow velocity was significantly lower than that before the treatment (P<0.05), and the resistance index was increased (P<0.05). However, the portal vein blood flow velocity had no significantly change (P>0.05). The blood flow signal in all tumors was rich before embolization. After TACE, the blood flow signal was significantly decreased, even partly disappeared in the anti-angiogenesis group. Conclusion: TACE with endostatin can effectively block the blood supplement of VX2 hepatic implantation tumor. Doppler ultrasonography can detected the blood flow changes and can be used in evaluating the therapeutic effect in hepatic implantation tumor. (authors)

  19. Ultrasonography as a better diagnostic efficiency in rib fracture

    OpenAIRE

    UZUN, Metin; BEKSAÇ, Burak; KARATAŞ, Adnan; KÜÇÜKDURMAZ, Fatih; KIRCALI, Bahar ANAYURDU; TETİK, Cihangir

    2013-01-01

    In this study, our aim was to demonstrate the need of use of ultrasonography in rib fractures in order not to face medicolegal problems. One hundred patients admitted to our emergency service with mild to moderate blunt thorax trauma were included in our study prospectively. The inclusion criteria were pain upon palpation of ribs, deep inspiration, coughing but no any other pathologies like a pneumothorax, hemothorax. All patients are evaluated with ultrasonography (USG) and direct X-rays. X-...

  20. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography.

  1. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    International Nuclear Information System (INIS)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum

    2017-01-01

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography

  2. Acute diverticulitis of the terminal ileum: ultrasonography and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jewon; Hong, Seong Sook; Hwang, Ji Young; Kim, Hyun Joo; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    We describe a rare case of terminal ileal diverticulitis in a 68-year-old female with a day of history Epub ahead of print of right lower quadrant pain and tenderness, mimicking acute appendicitis. Ultrasonography revealed small sac-like out-pouching lesions with increased echogenicity of surrounding fat in thickened terminal ileum, suggesting inflamed diverticula. We diagnosed terminal ileal diverticulitis primarily by ultrasonography. The diagnosis was confirmed by subsequent computed tomography.

  3. Ultrasonography of the shoulder: pitfalls and variants

    International Nuclear Information System (INIS)

    Friedman, L.; Finlay, K.; Popowich, T.; Jurriaans, E.

    2002-01-01

    Ultrasonography (US) of the shoulder, particularly the evaluation of the rotator cuff, is the most common examination of the musculoskeletal system performed in most practices. Despite this, it remains one of the most difficult examinations to learn. There are many pitfalls and errors that can occur initially, but once mastered, US of the rotator cuff is one of the best methods available for diagnosing rotator cuff disease. The literature reports a 91%-95% sensitivity and close to 90% specificity and accuracy in the assessment of both partial and full thickness tears. This compares favourably with magnetic resonance imaging (MRI), where a more recent study reported an 84% sensitivity, 97% specificity and an accuracy of 93% for combined partial and full thickness tears of the rotator cuff. Advantages of US include low cost, easy access, high degree of accuracy in expert hands, ease of comparison with the opposite side, dynamic real-time examination, ability to focus on the exact site of the patient's pain and graded compression availability. It is for these reasons that we hope to outline the various pitfalls and common errors that can occur during the examination in a systematic fashion. It must also be pointed out that computed tomographic arthrography and magnetic resonance arthrography remain the investigations of choice for assessing labral disorders. (author)

  4. New endoscopic ultrasonography techniques for pancreticobiliary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kamata, Ken; Kitano, Masayuki; Omoto, Shunsuke; Kadosaka, Kumpei; Miyata, Takeshi; Minaga, Kosuke; Yamao, Kentaro; Imai, Hajime; Kudo, Masatoshii [Dept. of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka (Japan)

    2016-07-15

    Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.

  5. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  6. En bloc kidney transplantation: ultrasonography assessment

    International Nuclear Information System (INIS)

    Arenal, F.; Ganado, T.; Merino, M.S.; Contreras, E.; Hernandez, J.; Prats, D.

    1997-01-01

    The objective of our study is to assess the utility of ultrasonography in the study of the complications associated with en bloc kidney transplantation. Twenty-three recipients of double transplants from donors under the age of 3 years were studied. Ultrasound (mode B: pulsed Doppler and color Doppler) was performed within the first three postoperative days and was repeated at 6 and 12 months. The morphology of the graft and renal blood flow were assessed, and the indices of pulsatility, resistance and acceleration were measured. Four patients required graft explanation: three due to massive hemorrhagic infarction and one due to venous thrombosis. Vascular complications were detected in five transplants (21.7%), urological complications in four (17.4%) and medical complications in two (8.7%). The most common vascular complication was unilateral renal artery stenosis. Color Doppler ultrasound diagnosed all the medical and urological complications and three of the five cases of vascular pathology (60%). Renal size was seen to be increased during the first postoperative year. The ultrasonographic study is more difficult to perform in en bloc kidney transplantation than in single kidney grafting: however, given its marked sensitivity in the detection of postransplantation complications. Doppler ultrasound is the imaging technique of choice in the determination of the cause of deteriorated kidney function. (Author) 15 refs

  7. Changes in Renal Resistive lndex in Patients with Liver Cirrhosis

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, Sung Woo; Yang, Geun Seok; Kim, Tae Hun; Lee, Yang Il

    1995-01-01

    The purpose of this study was to determine wheter duplex ultrasonography can allow early detection of renal functional impairment identity the patients under high risk for renal failure among thore with liver cirrhosis. We measured the intrarenal resistive index by using duplex ultrasonography in 26 patients of liver cirrhosis with normal renal function test. For statistical comparison, we measured the intrarenal resistive index of 10 adults with normal liver and kidneys. We evaluated the relationships between theseverity of liver cirrhosis and intrarenal resistive index. We also calculated the difference in intrarenalresistive index between the patients with ascites and those without ascites. The intrarenal resistive index in cirrhotic patients group(0.67±0.065) was significantly higher than that in control group(0.56±0.007).The intrarenal resistive index of patients with ascites (0.70±0.052) was also higher than that of those without ascites (0.60±0.033). The intrarenal resistive index of the patients with Child class C disease (0.73±0.036) was higher than the resistive index of those with Child class A disease (0.60±0.043) and those with Child class B(0.64±0.037). Renal resistive index measurement by non-invasive duplex ultrasonography can detect subtle derangement of renal hemodynamics in liver cirrhosis and may be useful for identification of patients with higher risk of renal failure and to guide the therapeutic approach

  8. Liver Immunology

    Science.gov (United States)

    Bogdanos, Dimitrios P.; Gao, Bin; Gershwin, M. Eric

    2014-01-01

    The liver is the largest organ in the body and is generally regarded by non-immunologists as not having lymphoid function. However, such is far from accurate. This review highlights the importance of the liver as a lymphoid organ. Firstly, we discuss experimental data surrounding the role of liver as a lymphoid organ. The liver facilitates a tolerance rather than immunoreactivity, which protects the host from antigenic overload of dietary components and drugs derived from the gut and is also instrumental to fetal immune tolerance. Loss of liver tolerance leads to autoaggressive phenomena which if are not controlled by regulatory lymphoid populations may lead to the induction of autoimmune liver diseases. Liver-related lymphoid subpopulations also act as critical antigen-presenting cells. The study of the immunological properties of liver and delineation of the microenvironment of the intrahepatic milieu in normal and diseased livers provides a platform to understand the hierarchy of a series of detrimental events which lead to immune-mediated destruction of the liver and the rejection of liver allografts. The majority of emphasis within this review will be on the normal mononuclear cell composition of the liver. However, within this context, we will discus select, but not all, immune mediated liver disease and attempt to place these data in the context of human autoimmunity. PMID:23720323

  9. Ultrasonographic features of the liver with cystic echinococcosis in sheep

    Science.gov (United States)

    Hussein, Hussein Awad; Elrashidy, Mohammed

    2014-01-01

    Objectives The present study was designed to gain information about the ultrasonographic features of livers with cystic echinococcosis, as well as to evaluate the use of ultrasonography for diagnosis of such disease in sheep. Design This was a retrospective study during the period April 2011 to March 2013. Participants A total of 22 Baladi sheep (aged three to six years) were included in this study. Based on clear hepatic ultrasonographic findings, all animals were classified into two groups: those with hepatic cysts (n=9) and without liver cysts (healthy liver, n=13). Results Biochemically, serum concentrations of γ-glutamyl transferase, aspartate aminotransferase, total bilirubin and globulins were significantly increased (P<0.01), while albumin was lowered (P<0.01) in sheep with cystic livers. Ultrasonographic findings of diseased sheep livers revealed the presence of rounded, anechoic and unilocular hydatid cysts with ellipse circumference ranged from 6–10 cm. The borders of cysts were mostly well defined. The interior of cysts contained echogenic particulate materials, septations, or fine echoes. At the 10th intercostal space, the ventral margin, size, thickness and angle of livers were higher (P<0.01), while the diameter of portal vein was lower (P<0.01) in sheep with liver cysts than control ones. Furthermore, at the 9th intercostal space, the circumference of the gall bladder was decreased in sheep with hepatic cysts (P<0.01). The sensitivity, specificity, and positive and negative predictive values of ultrasonography for diagnosis of hepatic hydatid cysts were 80 per cent and 100 per cent, and 100 per cent and 83 per cent, respectively. Conclusions Cystic echinococcosis is associated with a number of anatomical alterations in the liver tissues that can be easily recognised by ultrasound. Furthermore, ultrasonography alone or in combination with analysis of biochemical parameters reflecting liver function could be helpful for diagnosis of hepatic

  10. The Correlation of Sonographic Finding of Fatty Liver with Hematologic Examination and Body Fat Percentage

    International Nuclear Information System (INIS)

    Cheon, Hae Kyung; Lee, Tae Yong; Kim, Young Ran

    2009-01-01

    Ultrasonography has been used as a basic examination of a medical check up for prevention and diagnostics of diseases. Even the person who has no particular subjective symptoms can have a variety of diseases. Especially fatty liver is found in many cases. In this study, we tested 3582 persons who are in between the ages of 15 to 81 and observed that 1390 persons had fatty liver while 2192 persons are normal. We classified the grade of fatty liver and compared their life styles with the results of liver function test and BMI. The results are as follows. Ratio of the subjects who had a fatty liver is 38.8%. Male and female ratio was 46.2% and 24.2%. On the correlation among the fatty liver, the body mass index and the body fat, the average value of body mass index and body fat were significantly higher in the group of the fatty liver than in those of the normal liver. The influence of the related factor and the correlation on the fatty liver was shown that it was more related with the order of age, body mass index, triglyceride, ALT, body fat, sex, HDL-Cholesterol, LDL-Cholesterol, and GGT. The result of the ultrasonography carried out for the purpose of regular health check up indicates that even the 38.8% of those who was diagnosed as normal condition could have the fatty liver and have possibility of other diseases. Therefore, if there are any troubles related to liver function and lipid through hematologic examination or when practicing follow-up study with ultrasonography concerning the correlation relation between the body fat and dietary preference, alcohol consumption and exercise, the ultrasonography is definitely useful for prevention and treatment of diseases.

  11. The Correlation of Sonographic Finding of Fatty Liver with Hematologic Examination and Body Fat Percentage

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Hae Kyung [Dept. of Radiology, Sun General Hospital, Daejeon (Korea, Republic of); Lee, Tae Yong; Kim, Young Ran [Dept. of Preventive Medicine and Public Health College of Midicin, Chungnam National University, Daejeon (Korea, Republic of)

    2009-12-15

    Ultrasonography has been used as a basic examination of a medical check up for prevention and diagnostics of diseases. Even the person who has no particular subjective symptoms can have a variety of diseases. Especially fatty liver is found in many cases. In this study, we tested 3582 persons who are in between the ages of 15 to 81 and observed that 1390 persons had fatty liver while 2192 persons are normal. We classified the grade of fatty liver and compared their life styles with the results of liver function test and BMI. The results are as follows. Ratio of the subjects who had a fatty liver is 38.8%. Male and female ratio was 46.2% and 24.2%. On the correlation among the fatty liver, the body mass index and the body fat, the average value of body mass index and body fat were significantly higher in the group of the fatty liver than in those of the normal liver. The influence of the related factor and the correlation on the fatty liver was shown that it was more related with the order of age, body mass index, triglyceride, ALT, body fat, sex, HDL-Cholesterol, LDL-Cholesterol, and GGT. The result of the ultrasonography carried out for the purpose of regular health check up indicates that even the 38.8% of those who was diagnosed as normal condition could have the fatty liver and have possibility of other diseases. Therefore, if there are any troubles related to liver function and lipid through hematologic examination or when practicing follow-up study with ultrasonography concerning the correlation relation between the body fat and dietary preference, alcohol consumption and exercise, the ultrasonography is definitely useful for prevention and treatment of diseases.

  12. Liver spots

    Science.gov (United States)

    ... skin changes - liver spots; Senile or solar lentigines; Skin spots - aging; Age spots ... Liver spots are changes in skin color that occur in older skin. The coloring may be due to aging, exposure to the sun ...

  13. Liver Diseases

    Science.gov (United States)

    Your liver is the largest organ inside your body. It helps your body digest food, store energy, and remove poisons. There are many kinds of liver diseases: Diseases caused by viruses, such as hepatitis ...

  14. Liver disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000205.htm Liver disease To use the sharing features on this page, please enable JavaScript. The term "liver disease" applies to many conditions that stop the ...

  15. Serial 2-point ultrasonography plus D-Dimer vs whole-leg color-coded doppler ultrasonography for diagnosing suspected symptomatic deep vein thrombosis - A randomized controlled trial

    NARCIS (Netherlands)

    Bernardi, Enrico; Camporese, Giuseppe; Buller, Harry R.; Siragusa, Sergio; Imberti, Davide; Berchio, Arrigo; Ghirarduzzi, Angelo; Verlato, Fabio; Anastasio, Raffaela; Prati, Carolina; Piccioli, Andrea; Pesavento, Raffaele; Bova, Carlo; Maltempi, Patrizia; Zanatta, Nello; Cogo, Alberto; Cappelli, Roberto; Bucherini, Eugenio; Cuppini, Stefano; Noventa, Franco; Prandoni, Paolo

    2008-01-01

    Context Patients with suspected deep vein thrombosis ( DVT) of the lower extremities are usually investigated with ultrasonography either by the proximal veins ( 2-point ultrasonography) or the entire deep vein system ( whole- leg ultrasonography). The latter approach is thought to be better based

  16. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  17. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  18. Clinical evaluation of synthetic aperture sequential beamforming ultrasound in patients with liver tumors

    DEFF Research Database (Denmark)

    Hansen, Peter Møller; Hemmsen, Martin Christian; Brandt, Andreas Hjelm

    2014-01-01

    Medical ultrasound imaging using synthetic aperture sequential beamforming (SASB) has for the first time been used for clinical patient scanning. Nineteen patients with cancer of the liver (hepatocellular carcinoma or colorectal liver metastases) were scanned simultaneously with conventional...

  19. Role of endoscopic ultrasonography in treatment and prognostic evaluation of esophageal and gastric varices

    Directory of Open Access Journals (Sweden)

    LI Shuang

    2016-12-01

    Full Text Available Through a comprehensive evaluation of collateral circulation establishment in portal hypertension, endoscopic ultrasonography (EUS not only helps to predict and evaluate the risks of first bleeding from esophageal and gastric varices and recurrence and rebleeding after treatment, but also guides and participates in the treatment of varices. This article introduces the unique advantages of EUS in the treatment and prognostic evaluation of esophageal and gastric varices and provides an important reference for individualized treatment of patients with liver cirrhosis complicated by esophageal and gastric varices. EUS also helps to improve treatment safety and response rate. EUS for the systematic treatment of portal hypertension has become a hot research topic in recent years.

  20. Ultrasonography findings of thyroid metastasis in a patient with hepatocellular carcinoma: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Ho; Park, Noh Hyuck; Lim, Jae Hoon; Park, Chan Sub; Seong, Su Ok; Kwon, Tae Jung [Myongji Hospital, Goyang (Korea, Republic of)

    2015-03-15

    Although the thyroid gland is one of the most vascular organs of the body, metastatic disease in the thyroid is encountered infrequently. However, at autopsy, the incidence rate of thyroid metastasis ranges from 1.25% to 24%. The primary sites are the kidney, lung, breast, and gastrointestinal tract. We report a rare case of a hepatocellular carcinoma metastatic to the thyroid gland. The patient had multiple palpable masses in the anterior and left lateral neck along the internal jugular chain on physical examination 9 months after the initial diagnosis of liver tumor. These masses were confirmed as metastasis from hepatocellular carcinoma by ultrasonography-guided 16-G core needle biopsy. We discuss the sonographic findings of thyroid metastasis and their use as an additional aid for differentiating between unknown primary tumor and thyroid metastasis.

  1. Nanoparticles as image enhancing agents for ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Liu Jun [Biomedical Engineering Department, Ohio State University, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH 43210 (United States); Levine, Andrea L [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Mattoon, John S [Department of Veterinary Clinical Sciences, Ohio State University, 1151 Veterinary Hospital, 601 Vernon Tharp St., Columbus, OH 43210 (United States); Yamaguchi, Mamoru [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Lee, Robert J [Division of Pharmaceutics, College of Pharmacy, NCI Comprehensive Cancer Center, and NSF Nanoscale Science and Engineering Center, Ohio State University, 500 West 12th Avenue, Columbus, OH 43210 (United States); Pan Xueliang [Department of Statistics, Ohio State University, 1958 Neil Avenue, Columbus, OH 43210 (United States); Rosol, Thomas J [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States)

    2006-05-07

    Nanoparticles have drawn great attention as targeted imaging and/or therapeutic agents. The small size of the nanoparticles allows them to target cells that are beyond capillary vasculature, such as cancer cells. We investigated the effect of solid nanoparticles for enhancing ultrasonic grey scale images in tissue phantoms and mouse livers in vivo. Silica nanospheres (100 nm) were dispersed in agarose at 1-2.5% mass concentration and imaged by a high-resolution ultrasound imaging system (transducer centre frequency: 30 MHz). Polystyrene particles of different sizes (500-3000 nm) and concentrations (0.13-0.75% mass) were similarly dispersed in agarose and imaged. Mice were injected intravenously with nanoparticle suspensions in saline. B-mode images of the livers were acquired at different time points after particle injection. An automated computer program was used to quantify the grey scale changes. Ultrasonic reflections were observed from nanoparticle suspensions in agarose gels. The image brightness, i.e., mean grey scale level, increased with particle size and concentration. The mean grey scale of mouse livers also increased following particle administration. These results indicated that it is feasible to use solid nanoparticles as contrast enhancing agents for ultrasonic imagin000.

  2. Measurement of Gallbladder Volume with Ultrasonography in Pregnant Women

    Directory of Open Access Journals (Sweden)

    Sait Kapicioglu

    2000-01-01

    Full Text Available Fasting and postprandial gallbladder volumes were investigated using ultrasonography in three groups (10 subjects in each of healthy women: third trimester pregnant women, postpartum women up to 10 days after giving birth and nonpregnant controls. The scans were performed at 09:00 after a 12 h fast. After the basal measurement was taken, gallbladder volumes were rescanned in 15 min intervals for 60 mins. At the end of this period, all volunteers received a standard liquid test meal, and scans were performed again for 1 h. The mean basal gallbladder volume was 22.2±4.2 mL in the nonpregnant (control group. In the third trimester group, the basal volume was 37.8±10.5 mL – 70.5% higher than in the nonpregnant group (P<0.001. In the postpartum group, the mean basal volume was 37.9% lower (27.4±6.5 mL than that of the third trimester group (P<0.02. This basal volume was 23.6% greater than that of the control group (P<0.05. After administration of a test meal, the postprandial gallbladder volumes decreased during the first few minutes compared with baseline values. The volumes decreased by 10.2% to 39.8% (23.5±7.3 to 34.0±10.2; P<0.01 in the third trimester group, by 14.9% to 43.2% (16.6±4.3 to 23.3±5.5; P<0.01, 0.001 in the postpartum group and by 19.2% to 51.6% (11.9±3.5 to 17.9±3.6; P<0.02, 0.05, 0.01, 0.001 in the control group. Postprandial mean gallbladder volumes of the third trimester (P<0.02 and postpartum groups (P<0.02 to 0.01 were significantly different from those of the control group. In conclusion, incomplete emptying of the gallbladder after eating during the third trimester of pregnancy may contribute to cholesterol-gallstone formation, and pregnancy may thus increase the risk of gallstones.

  3. Endoscopic ultrasonography-guided rendezvous technique.

    Science.gov (United States)

    Tsuchiya, Takayoshi; Itoi, Takao; Sofuni, Atsushi; Tonozuka, Ryosuke; Mukai, Shuntaro

    2016-04-01

    Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS-RV) is a useful salvage method. From the previous 15 articles that included 382 EUS-RV cases, the overall success rate of EUS-RV is 81 % with a complication rate of 10 %. In EUS-RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS-RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS-RV is critical, a hydrophilic GW is useful for this procedure. Although EUS-RV is now performed relatively routinely in a few high-volume centers, procedure standardization and the development of exclusive devices for EUS-RV are still underway. The development of exclusive devices for EUS-RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.

  4. Evaluation of Snake Bites with Bedside Ultrasonography

    Directory of Open Access Journals (Sweden)

    Josef E Jolissaint

    2018-04-01

    Full Text Available History of present illness: While watering his lawn, a 36-year-old man felt two sharp bites to his bilateral ankles. He reports that he then saw a light brown, 2-foot snake slither away from him. He came to the emergency department because of pain and swelling in his ankles and inability to bear weight. Physical examination revealed bilateral ankle swelling and puncture marks on his left lateral heel and medial right ankle. Palpation, passive flexion and extension elicited severe pain bilaterally. Blood work including prothrombin time (PT, partial thromboplastin time (PTT, international normalized ratio (INR, and fibrinogen were within normal limits. Consultation with Poison Control indicated the snake was likely a copperhead, which is a venomous snake whose bites rarely require antivenin. Significant findings: In this case, ultrasonography of the lateral surface of the left foot revealed soft tissue edema (red arrow and fluid collection (white asterisk adjacent to the extensor tendon (white arrow. The edematous area resembles cobblestones, with hypoechoic areas of fluid spanning relatively hyperechoic fat lobules. The tendon is surrounded by anechoic fluid, expanding the potential space in the sheath. No hyperechoic foreign objects were noted. Discussion: The patient was diagnosed with soft tissue injury and extensor tenosynovitis after a snake envenomation. Snake venom contains metalloproteinases and other enzymatic proteins that cause local tissue edema and necrosis.1 After a snake bite, ultrasound can be used to assess for retained fangs, soft tissue edema, tendon sheath fluid, muscle fasciculation, and injury to deeper musculature that may not be readily apparent on physical exam.2,3 Most patients with tenosynovitis will recover with immobilization of the joint and non-steroidal anti-inflammatory medications.4 Rarely, the tendon may become infected requiring antibiotics and surgical intervention.4 Topics: Ultrasound, snake envenomation

  5. II Brazilian consensus statement on endoscopic ultrasonography.

    Science.gov (United States)

    Maluf-Filho, Fauze; de Oliveira, Joel Fernandez; Mendonça, Ernesto Quaresma; Carbonari, Augusto; Maciente, Bruno Antônio; Salomão, Bruno Chaves; Medrado, Bruno Frederico; Dotti, Carlos Marcelo; Lopes, César Vivian; Braga, Cláudia Utsch; M Dutra, Daniel Alencar; Retes, Felipe; Nakao, Frank; de Sousa, Giovana Biasia; de Paulo, Gustavo Andrade; Ardengh, Jose Celso; Dos Santos, Juliana Bonfim; Sampaio, Luciana Moura; Okawa, Luciano; Rossini, Lucio; de Brito Cardoso, Manoel Carlos; Ribeiro Camunha, Marco Antonio; Clarêncio, Marcos; Lera Dos Santos, Marcos Eduardo; Franco, Matheus; Schneider, Nutianne Camargo; Mascarenhas, Ramiro; Roda, Rodrigo; Matuguma, Sérgio; Guaraldi, Simone; Figueiredo, Viviane

    2017-01-01

    At the time of its introduction in the early 80s, endoscopic ultrasonography (EUS) was indicated for diagnostic purposes. Recently, EUS has been employed to assist or to be the main platform of complex therapeutic interventions. From a series of relevant new topics in the literature and based on the need to complement the I Brazilian consensus on EUS, twenty experienced endosonographers identified and reviewed the pertinent literature in databases. The quality of evidence, strength of recommendations, and level of consensus were graded and voted on. Consensus was reached for eight relevant topics: treatment of gastric varices, staging of nonsmall cell lung cancer, biliary drainage, tissue sampling of subepithelial lesions (SELs), treatment of pancreatic fluid collections, tissue sampling of pancreatic solid lesions, celiac neurolysis, and evaluation of the incidental pancreatic cysts. There is a high level of evidence for staging of nonsmall cell lung cancer; biopsy of SELs as the safest method; unilateral and bilateral injection techniques are equivalent for EUS-guided celiac neurolysis, and in patients with visible ganglia, celiac ganglia neurolysis appears to lead to better results. There is a moderate level of evidence for: yield of tissue sampling of pancreatic solid lesions is not influenced by the needle shape, gauge, or employed aspiration technique; EUS-guided and percutaneous biliary drainage present similar clinical success and adverse event rates; plastic and metallic stents are equivalent in the EUS-guided treatment of pancreatic pseudocyst. There is a low level of evidence in the routine use of EUS-guided treatment of gastric varices.

  6. Ultrasonography in Gastroenterology: The Need for Training

    Directory of Open Access Journals (Sweden)

    João Pinto

    2018-02-01

    Full Text Available The use of ultrasonography (US as an imaging modality in medicine has spread across almost every clinical specialty. This diffusion is based on the simplicity, accessibility, portability and affordability of the technique producing real-time high-resolution images using non-ionising radiation. On the other hand, this trend also extended the technique to settings other than healthcare, such as public facilities, private houses or remote sites. This tendency can be observed worldwide, from developing countries to prestigious medical schools and tertiary referral hospitals. Furthermore, point-of-care US (POCUS, i.e., US executed at the patient’s bedside to obtain real-time objective information with diagnostic and clinical monitoring purposes or to guide invasive procedures, has been incorporated in many specialties. In gastroenterology, despite the essential role of endoscopy, clinical practice is highly dependent on non-endoscopic imaging techniques. However, as in other specialties, the indications of US in gastroenterology have been increasing steadily, covering a broad range of conditions. In response to the generalised employment of US by non-radiologists, institutions such as the European Federation of Societies for Ultrasound in Medicine and Biology and the Royal College of Radiologists issued recommendations to ensure high-quality practice. These theoretical and practical requisites include performing a certain number of examinations and mandatory skills in order to achieve certification to execute unsupervised US. Therefore, there is a need for modern gastroenterology to include US as a basic skill in its clinical practice. To ensure the provision of high-quality US, adequate instruction of future specialists should be guaranteed by the gastroenterology departments and required in the residency training programme.

  7. Evaluation of normal masseter muscles on ultrasonography

    International Nuclear Information System (INIS)

    Hwang, Hyoung Zoo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2008-01-01

    To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and x2-test. 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  8. Scanning table

    CERN Multimedia

    1960-01-01

    Before the invention of wire chambers, particles tracks were analysed on scanning tables like this one. Today, the process is electronic and much faster. Bubble chamber film - currently available - (links can be found below) was used for this analysis of the particle tracks.

  9. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  10. Radiologic evaluation of nonalcoholic fatty liver disease

    Science.gov (United States)

    Lee, Seung Soo; Park, Seong Ho

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a frequent cause of chronic liver diseases, ranging from simple steatosis to nonalcoholic steatohepatitis (NASH)-related liver cirrhosis. Although liver biopsy is still the gold standard for the diagnosis of NAFLD, especially for the diagnosis of NASH, imaging methods have been increasingly accepted as noninvasive alternatives to liver biopsy. Ultrasonography is a well-established and cost-effective imaging technique for the diagnosis of hepatic steatosis, especially for screening a large population at risk of NAFLD. Ultrasonography has a reasonable accuracy in detecting moderate-to-severe hepatic steatosis although it is less accurate for detecting mild hepatic steatosis, operator-dependent, and rather qualitative. Computed tomography is not appropriate for general population assessment of hepatic steatosis given its inaccuracy in detecting mild hepatic steatosis and potential radiation hazard. However, computed tomography may be effective in specific clinical situations, such as evaluation of donor candidates for hepatic transplantation. Magnetic resonance spectroscopy and magnetic resonance imaging are now regarded as the most accurate practical methods of measuring liver fat in clinical practice, especially for longitudinal follow-up of patients with NAFLD. Ultrasound elastography and magnetic resonance elastography are increasingly used to evaluate the degree of liver fibrosis in patients with NAFLD and to differentiate NASH from simple steatosis. This article will review current imaging methods used to evaluate hepatic steatosis, including the diagnostic accuracy, limitations, and practical applicability of each method. It will also briefly describe the potential role of elastography techniques in the evaluation of patients with NAFLD. PMID:24966609

  11. Profile of liver enzymes in non-alcoholic fatty liver disease in patients with impaired glucose tolerance and newly detected untreated type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Debmalya Sanyal

    2015-01-01

    Full Text Available Context: The perception of non-alcoholic fatty liver disease (NAFLD as an uncommon and benign condition is rapidly changing. Approximately, 70% type 2 diabetes mellitus (T2DM patients have a fatty liver, which may follow an aggressive course with necroinflammation and fibrosis. Aims: To assess the profile of liver enzymes in subjects with impaired glucose tolerance (IGT, new onset treatment naive T2DM and normal glucose tolerance (NGT with and without NAFLD. Settings and Design: Cross-sectional clinic-based study. Subjects and Methods: 152 IGT and 158 recently detected T2DM subjects aged between 30 and 69 years, along with 160 age and gender matched controls with NGT. An ultrasonography scan of the upper abdomen was done in all patients in order to examine presence of fatty liver. Anthropometry, lipid profile, liver enzymes were also analyzed in all patients. Statistical Analysis Used: Unpaired t-test, Chi-square/Fisher Exact test (for categorical variables, Pearson/Spearmen correlation test to find significant difference, association and correlation between two or more groups respectively. Results: NAFLD was significantly associated with higher alanine aminotransferase (ALT and gamma-glutamyl transferase (GGT but not ALP levels in IGT and T2DM patients. ALT, GGT significant correlated with waist circumference, body mass index, fasting insulin, homeostatic model assessment- insulin resistance, fasting blood glucose, high density lipoprotein cholesterol, triglyceride. 57% of NAFLD patients had normal ALT between 25 and 40 U/L, 53% of NAFLD subjects had normal GGT between 15 and 30 U/L. ALT 40 U/L and GGT > 30 U/L had highest positive predictivity for presence of NAFLD in our study sample. Conclusions: Mild elevations of liver enzymes in the upper normal range are associated with features of metabolic syndrome and NAFLD even in IGT and recently detected T2DM patients. Novel cut-offs for liver enzymes are warranted in order to prevent unnecessary

  12. A study on abdomen ultrasonography classified by particular disease practiced in health promotion center of a university hospital

    International Nuclear Information System (INIS)

    Kim, Nam Hee; Choi, Jong Hak

    2001-01-01

    This study is to get preliminary data for an effectiveness evaluation of abdominal examination and improvement of it. Abnormal cases of abdominal ultrasonography are classified by sex, frequency, diagnosis and age, 4.924 examinees were included at a university hospital of health promotion center from January to December in 1999. The results are as follow. According to the distribution of sex, there are more male patients(55.0%) than females patients (48.0%). for men, 40's showed the highest percentage among examinees. For women, 50's were the highest. The reason that 'they visited the health promotion center was that they wanted to check their health status'. This answers were reported the highest (59.3%). Patients that had abnormal cases of abdominal ultrasonography were 48.3%. Liver, kidney, gallbladder showed the highest percentage of abnormal cases in order of organs. Additionally, abnormal cases were discovered in liver cases. According to the frequency of abnormal cases among examinees, the slight fatty liver were the highest regardless of sex. Men had the slight fatty liver, kidney simple cyst, liver calcification and liver simple cyst in order of abnormal cases. Women showed the slight fatty liver kidney simple cyst, kidney calcification, liver simple cyst, and blood vessel tumor in order of abnormal cases. For the abnormal cases of live by sex and age, the 50's reported the highest number of abnormal cases in men (299 patients). In addition, 60's had the highest of disease rata 47.8%. For women, 50's reported the highest number of abnormal cases (361 patients).. Over 70's patients had the highest of disease rata 52.6%. For kidney, men and women showed the highest number of abnormal cases -62 vs 44 respectively. Over 70's patients had the highest percentage of disease rata -23.2% vs 14.0% respectively. For gallbladder, the number of abnormal cases were the most in men's 60's (31 patients) and in women's in the same age group (32 patients). According to

  13. Role of perineal ultrasonography in postoperative evaluation of patients with stress incontinence

    International Nuclear Information System (INIS)

    Ko, Seog Wan; Jeong, Yong Yeon; Kang, Heoung Keun; Chung, Tae Woong; Seo, Jeong Jin; Park, Jin Gyoon; Kwon, Dong Deuk

    2001-01-01

    To evaluate the effectiveness of perineal ultrasonography in the evaluation of female stress incontinence after surgical management. Perineal ultrasonography was performed in 19 patients who were surgically treated for stress incontinence and this was performed in erect position. Nineteen patients were divided into two groups, group A for 11 patients with resolved incontinent after surgery and group B for 8 patients with persistent incontinence even after surgery. Using a sagittal scan of the anterior pelvis at the level of the symphysis pubis, the posterior urethrovesical angel (PUVA) and descent of the bladder neck were measured at rest and during stress (Valsalva maneuver), and these measured values obtained before and after surgery were compared between two groups, group A and B. Postoperative PUVA and descent of the bladder neck were decreased when compared with preoperative values measured at rest and during stress in both groups. There was a statistically significant difference in the postoperative PUVA between two groups (p< 0.05). The mean increment of PUVA during stress after surgery was 6.3 ± 3.8. deg in group A and 14.6 ± 6.4. deg in group B, respectively, showing statistically significant difference (p< 0.05). There was also a statistically difference in the mean descent of the bladder neck during stress after surgery between the two groups (p<0.05). The measurement and comparison of PUVA and descent of the bladder neck by perineal ultrasonography before and after surgery in patients with stress incontinence offered useful and objective information in evaluating the effectiveness of surgical management in females stress incontinence, the stress effectiveness in the stress incontinence.

  14. Effect of provider experience on clinician-performed ultrasonography for hydronephrosis in patients with suspected renal colic.

    Science.gov (United States)

    Herbst, Meghan K; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P; Singh, Dinesh; Molinaro, Annette M; Luty, Seth; Moore, Christopher L

    2014-09-01

    Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non-attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non-attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95% confidence interval [CI] 65.4% to 78

  15. Evaluation of the use of laparoscopic-guided cholecystocholangiography and liver biopsy in definitive diagnosis of neonatal cholestatic jaundice

    Directory of Open Access Journals (Sweden)

    Khalid Shreef

    2016-01-01

    Full Text Available Background: Once it is established that a jaundiced infant has direct hyperbilirubinemia, the principal diagnostic concern is to differentiate hepatocellular from obstructive cholestasis. Traditional tests such as ultrasonography, percutaneous liver biopsy and technetium 99 m hepatobiliary iminodiacetic acid (HIDA scan are often not sufficiently discriminating. Definitive exclusion of biliary atresia (BA in the infant with cholestatic jaundice usually requires mini-laparotomy and intra-operative cholangiography. This approach has many drawbacks because those sick infants are subjected to a time-consuming procedure with the probability of negative surgical exploration. Aim of the Study: The aim of this study was to determine the feasibility of laparoscopic-guided cholecystocholangiography (LGCC and its accuracy and safety in the diagnosis of BA and thus preventing unnecessary laparotomy in infants whose cholestasis is caused by diseases other than BA. Patients and Methods: Twelve cholestatic infants with direct hyperbilirubinemia subjected to LGCC (age, 7–98 days; mean, 56 days after ultrasound scan and (99 mTc HIDA scan and percutaneous liver biopsy failed to provide the definitive diagnosis. Results: One patient had completely absent gall bladder (GB so the laparoscopic procedure was terminated and laparotomy was done (Kasai operation. Four patients had small size GB; they underwent LGCC that showed patent common bile duct with atresia of common hepatic duct, so laparotomy and Kasai operation was performed. Seven patients had well-developed GB, LGCC revealed patent biliary tree, so laparoscopic liver biopsies were taken for histopathology. Five of those patients had neonatal hepatitis, and two had cholestasis as a complication of prolonged TPN. No perioperative complications or mortalities were recorded. Conclusion: When the diagnosis neonatal cholestasis remains elusive after traditional investigations, LGCC is an accurate and simple method

  16. Evaluation of breast symptoms with mammography and ultrasonography

    Directory of Open Access Journals (Sweden)

    Emine Devolli Disha

    2011-12-01

    Full Text Available Introduction: Aim of the study was to discern which are more frequent symptoms presented in malign and benign masses diagnosed by mammography and ultrasonography.Methods: Our study group consisted of 546 female patients, with breast symptoms such as palpable lumps (40.8%, pain in the breast (26%, localized lumpiness or nodularity (13.7%, nipple retraction (11.2%, nipplebloody discharge (5.1% and redness and swelling of the breast (3.1%. All 546 patients were examined by ultrasonography and mammography. Biopsy was performed according to the findings of mammography and ultrasonography.Results: In breast cancer detection ultrasonography showed an efficiency of 79.4% compared to 55.0% for mammography in detecting breast lump, in the case of nipple retraction mammography showed an efficiency of 89.1% compared to 80.4% for ultrasound, while the lowest efficiency for mammography was in the cases with localized lumpiness or nodularity 17.1% compared to 45.7% for ultrasound. In detecting fibrocystic changes where the most common symptoms was pain, ultrasonography showed an efficiency of 99.3 % compared to 84.2 % for mammography.Conclusions: Our study confirmed that breast lumps are detectable in the majority of patients with breast cancer. The most frequent symptoms in patient with benign lesions were pain or localized discomfort. The diagnostic accuracy for carcinomas of the breast and for benign lesions according to symptoms was higher for ultrasound than for mammography.

  17. Scanning holograms

    International Nuclear Information System (INIS)

    Natali, S.

    1984-01-01

    This chapter reports on the scanning of 1000 holograms taken in HOBC at CERN. Each hologram is triggered by an interaction in the chamber, the primary particles being pions at 340 GeV/c. The aim of the experiment is the study of charm production. The holograms, recorded on 50 mm film with the ''in line'' technique, can be analyzed by shining a parallel expanded laser beam through the film, obtaining immediately above it the real image of the chamber which can then be scanned and measured with a technique half way between emulsions and bubble chambers. The results indicate that holograms can be analyzed as quickly and reliably as in other visual techniques and that to them is open the same order of magnitude of large scale experiments

  18. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  19. Magnetic Resonance Imaging of Liver Metastasis.

    Science.gov (United States)

    Karaosmanoglu, Ali Devrim; Onur, Mehmet Ruhi; Ozmen, Mustafa Nasuh; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Cholescintigraphy and ultrasonography in patients suspected of having acute cholecystitis

    DEFF Research Database (Denmark)

    Lauritsen, K B; Sommer, W; Hahn, L

    1988-01-01

    The diagnostic power of combined cholescintigraphy and ultrasonography was tested in 67 patients suspected of having acute cholecystitis; of these, 42 (63%) had acute cholecystitis. The predictive value of a positive scintigraphy (PVpos) was 95% and that of a negative (PVneg) was 91% (n = 67......). The PVpos and PVneg of ultrasonography were 89% and 75%, respectively (n = 54), and these values did not achieve statistical significance when compared with those for scintigraphy. Inconclusive tests were 10% and 11%, respectively, but in no patient were both scintigraphy and ultrasonography inconclusive...... that in patients suspected of having acute cholecystitis cholescintigraphy should be the first diagnostic procedure performed. If the scintigraphy is positive, additional ultrasonographic detection of gallstones makes the diagnosis almost certain. If one diagnostic modality is inconclusive, the other makes a fair...

  1. Ultrasonography and radiography of the canine postpartum uterus

    International Nuclear Information System (INIS)

    Pharr, J.W.; Post, K.

    1992-01-01

    A vulvovaginal discharge following parturition in a bitch is often a cause of concern to owners and clinicians, especially if whelping was complicated in any way. Ultrasonography could potentially distinguish between normal and abnormal postpartum uterine states because the uterine wall and luminal contents can be imaged in detail. Five normal bitches were examined to determine the normal ultrasonographic appearance of the postpartum uterus and the sensitivity of ultrasonography in detecting the involuting uterus, comparing this sensitivity with that of radiography. Ultrasonography was done at 1, 4, 8, 12, 18 and 24 days postpartum, radiography at 1, 4, 8, 12 and 18 days postpartum. By 12 days postpartum, the uterus could not be seen on radiographs, while at 24 days postpartum the uterus was still sonographically identifiable. The ultrasonographic characteristics of the involuting uterus are described

  2. The diagnostic value of ultrasonography in the gyneocological emergency

    International Nuclear Information System (INIS)

    Su Hui; Chen Fanghua; Peng Xiulan

    2006-01-01

    Objective: To evaluate the ultrasonography in the diagnosis and differential diagnosis of gynecologic emergency. Methods: 138 patients suffered from gynecologic emergency were examined with ultrasonography. The images were retrospectively reviewed and compared with pathologic or clinical results. Results: The total correct diagnostic rate was 89.1%. Among 138 cases of gynecologic emergency, there were 45 cases of ectopic pregnancy, 27 cases of ruptured corpus luteum, 24 cases of torsion of ovarian cyst, and 42 cases of acute pelvic inflammation. The correct diagnostic rates were 91.1%, 81.5%, 87.5%, 92.2%, respectively. Conclusion: The ultrasonography plays an important role in the diagnosis of gynecological emergency. When the US findings were not typical, the clinical history, symptoms and HCG level should be considered in order to avoid misdiagnosis. (authors)

  3. Acoustic radiation force impulse elastography, FibroScan®, Forns' index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods.

    Science.gov (United States)

    Dong, Dao-Ran; Hao, Mei-Na; Li, Cheng; Peng, Ze; Liu, Xia; Wang, Gui-Ping; Ma, An-Lin

    2015-06-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns' index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty‑one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal‑Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal‑Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=‑0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of

  4. Comparison of gray-scale contrast-enhanced ultrasonography with contrast-enhanced computed tomography in different grading of blunt hepatic and splenic trauma: an animal experiment.

    Science.gov (United States)

    Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li

    2009-04-01

    To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.

  5. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang

    2009-01-01

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  6. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang [Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2009-12-15

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  7. Ultrasonography of hydronephrosis in the newborn: A practical review

    International Nuclear Information System (INIS)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn

  8. Ultrasonography of hydronephrosis in the newborn: a practical review

    Science.gov (United States)

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  9. Ultrasonography of hydronephrosis in the newborn: A practical review

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Children' s Hospital, Seoul (Korea, Republic of)

    2016-07-15

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn.

  10. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  11. Killian-Jamieson Diverticulum Mimicking a Thyroid Nodule on Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Kim, Eun Soo; Lee, Kwan Seop; Yoon, Hoi Soo; Jeon, Eui Yong; Hwang, Hee Sung; Koh, Sung Hye; Kim, Min Jeong; Jang, Kyung Mi; Lee, Myung Jun; Lee, Yul

    2007-01-01

    Thyroid ultrasonography is widely used for diagnosis and cytologic evaluation of thyroid nodules. We encountered a case of Killian-Jamieson diverticulum, which was differentiated from a thyroid nodule using ultrasonography

  12. Serum Fetuin-A levels in obese children with biopsy proven nonalcoholic fatty liver disease.

    Science.gov (United States)

    Pampanini, V; Inzaghi, E; Germani, D; Alterio, A; Puglianiello, A; Alisi, A; Nobili, V; Cianfarani, S

    2018-01-01

    Fetuin-A has been proposed as a marker of liver damage in adults with obesity-related NAFLD. The aim of this study was to test serum fetuin-A concentrations in obese children with NAFLD diagnosed either by ultrasonography or by liver biopsy and to determine its applicability as predictive tool in pediatric NAFLD. Metabolic parameters and fetuin-A levels were investigated in 81 obese children with NAFLD diagnosed by biopsy, 79 obese children with NAFLD defined by liver ultrasonography and 23 lean subjects. Serum fetuin-A correlated significantly with age, waist circumference, systolic blood pressure, fasting insulin and 2-h postload insulin during OGTT, HOMA-IR, ISI, CRP, and apo B levels. Obese children with NAFLD detected by ultrasonography had significantly higher fetuin-A levels compared to those with normal liver. In obese children who underwent liver biopsy, no significant differences were detected in fetuin-A levels between subject with nonalcoholic steatohepatitis and those with simple steatosis. Fetuin-A was not different between obese and lean children. Fetuin-A is not related with the degree of liver damage in obese children with NAFLD and its routine measurement as marker of liver disease severity is therefore not recommended. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  13. To intercompare and to test all the Nuclear Medicine procedures used in the Department of Nuclear Medicine for diagnostic and research purposes starting with and giving particular importance to the procedures for liver disease. Final report for the period 1985 - 1988

    International Nuclear Information System (INIS)

    Asghar, S.

    1988-01-01

    The study had the purpose to evaluate solitary liver defects with Tc-99m sulfur colloid and to assess the additional benefits by combining routine liver scan with liver blood pool image and Ga-67 liver imaging. 103 patients with various liver diseases having solitary liver defects on radionuclide liver scan were studied. Tabs

  14. Current role of bone scan with phosphonates in the follow-up of breast cancer

    International Nuclear Information System (INIS)

    Maffioli, Lorenzo; Florimonte, Luigia; Pagani, Luca; Butti, Ivana; Roca, Isabel

    2004-01-01

    A number of studies have demonstrated that bone scintigraphy has high sensitivity and efficacy in the early detection of bone metastases from several tumours, including breast cancer. Bone scintigraphy is the most definitive tool for diagnosing and monitoring metastatic spread of breast cancer. However, in the past decade there has been a wide debate on its impact on survival time, morbidity and quality of life. Worldwide economic restrictions and these studies have led to the adoption of an almost minimalist policy for breast cancer follow-up using evidence-based guidelines. The recommended breast cancer surveillance testing includes only a few procedures (history, physical and breast self-examination, patient education on symptoms, pelvic examination). The routine use of additional tests, such as blood cell count, tumour markers, liver ultrasonography, bone scan and chest X-rays, is not recommended. Accordingly, scintigraphy should be reserved for a limited number of patients. On the other hand, early diagnosis of bone involvement may reduce the risk of skeletal related events, thus leading to a significant improvement in quality of life. Furthermore, new drugs (e.g. bisphosphonates) can now delay the onset of bone metastasis and reduce the number of patients who experience skeletal complications. In conclusion, the evidence of the clinical usefulness of bone scintigraphy (to allow early planning of new treatments in advanced disease) has to be re-evaluated, possibly by large randomised prospective trials. (orig.)

  15. Liver Disease

    Science.gov (United States)

    ... and ridding your body of toxic substances. Liver disease can be inherited (genetic) or caused by a variety of factors that damage the ... that you can't stay still. Causes Liver disease has many ... or semen, contaminated food or water, or close contact with a person who is ...

  16. Liver scintigraphy

    International Nuclear Information System (INIS)

    Tateno, Yukio

    1996-01-01

    Liver scintigraphy can be classified into 3 major categories according to the properties of the radiopharmaceuticals used, i.e., methods using radiopharmaceuticals which are (1) incorporated by hepatocytes, (2) taken up by reticulo endothelial cells, and (3) distributed in the blood pool of the liver. Of these three categories, the liver scintigraphy of the present research falls into category 2. Radiopharmaceuticals which are taken up by endothelial cells include 198 Au colloids and 99m Tc-labelled colloids. Liver scintigraphy takes advantage of the property by which colloidal microparticles are phagocytosed by Kupffer cells, and reflect the distribution of endothelial cells and the intensity of their phagocytic capacity. This examination is indicated in the following situations: (i) when you suspect a localized intrahepatic lesion (tumour, abscess, cyst, etc.), (ii) when you want to follow the course of therapy of a localized lesion, (iii) when you suspect liver cirrhosis, (iv) when you want to know the severity of liver cirrhosis or hepatitis, (v) when there is hepatomegaly and you want to determine the morphology of the liver, (vi) differential diagnosis of upper abdominal masses, and (vii) when there are abnormalities of the right diaphragm and you want to know their relation to the liver

  17. Liver regeneration

    NARCIS (Netherlands)

    Chamuleau, R. A.; Bosman, D. K.

    1988-01-01

    Despite great advances in analysing hemodynamic, morphological and biochemical changes during the process of liver regeneration, the exact (patho)physiological mechanism is still unknown. A short survey of literature is given of the kinetics of liver regeneration and the significance of different

  18. Atlas-based knee osteophyte assessment with ultrasonography and radiography

    DEFF Research Database (Denmark)

    Koski, J M; Kamel, Ayadi; Waris, P

    2016-01-01

    OBJECTIVES: To investigate intra- and inter-reader agreement of ultrasonography (US) and conventional radiography (CR) for the evaluation of osteophyte presence and size within the tibiofemoral joint. In addition, to correlate these findings with arthroscopic degeneration of the articular cartila...

  19. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  20. An unanticipated diagnosis with bedside ultrasonography in patients ...

    African Journals Online (AJOL)

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and ...

  1. The accuracy rate of Alvarado score, ultrasonography, and ...

    African Journals Online (AJOL)

    Objective: In this study, we aim to compare the relationship between the Alvarado score, ultrasonography, and multislice computerized tomography (CT) findings used for the diagnosis of the patients who presented to our emergency unit with clinical features suggestive of acute appendicitis. Materials and Methods: ...

  2. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  3. Impact of magnetic resonance urography and ultrasonography on ...

    African Journals Online (AJOL)

    Background: (1) To evaluate the diagnostic value of magnetic resonance urography (MRU) in comparison with ultrasonography (US) to determine the extent of upper urinary tract dilation and (2) to evaluate the impact of MRU on therapy management. Materials and Methods: From January 2005 to December 2010, ...

  4. In-utero diagnosis of Norrie disease by ultrasonography.

    Science.gov (United States)

    Redmond, R M; Vaughan, J I; Jay, M; Jay, B

    1993-03-01

    Obstetric ultrasonography of an obligate Norrie disease carrier revealed bilateral retinal detachments in a third trimester male fetus. Postnatal examination confirmed the diagnosis of Norrie disease. DNA linkage analysis with the markers L1.28 and MAO had been uninformative for this family. This report suggests that retinal detachment occurs late in the gestation of the affected fetus.

  5. Primary muscular hydatid: preoperative diagnosis Throught computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Macho Fernandez, J.M.; Marin Cardenas, M.A.; Mazas Artasona, L.; Lample Lacasa, C.; Otero Sierra, C.; Hernandez Navarrete, M.J.; Gomez-Pereda, R.

    1995-01-01

    Primary muscular hydatid disease, is extremely rare,- but not exceptional-, comparatively with other atypical localization. In this article the authors revised 474 patients with hydatid disease over a ten years period. Three cases of primary muscular localization were found. The ultrasonography and computed tomography facilitates the preoperative diagnosis. (Author) 40 refs

  6. Evaluation of the hip joint by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Anda, S.

    1991-04-01

    In patients with dysplastic hips the acetabular angles and femoral anteversion were determined in a CT investigation. Comparative investigations of femoral anteversion were made by ultrasonography and biomedical radiography. The investigations are described and the general conclusions discussed. 205 refs., 15 figs., 10 tabs

  7. Severe portal hypertension in cirrhosis: evaluation of perfusion parameters with contrast-enhanced ultrasonography.

    Directory of Open Access Journals (Sweden)

    Woo Kyoung Jeong

    Full Text Available To investigate the role of contrast-enhanced ultrasonography (CEUS and Doppler ultrasonography (DUS in the diagnosis of severe portal hypertension (PH in patients with liver cirrhosis (LC.Patients with PH scheduled to receive hepatic venous pressure gradient (HVPG measurement were recruited for this study. Hepatic DUS and CEUS were performed successively. Several Doppler and CEUS parameters were explored for correlation with HVPG values and their association with severe PH (≥ 12 mmHg of HVPG. Comparison of the parameters between the severe and non-severe PH groups and their correlation with HVPG values was evaluated. A receiver operating characteristic (ROC curve analysis was also performed to investigate the performance in order to diagnose severe PH.Fifty-three consecutive patients were enrolled in this study. Among them, 43 patients did not have significant ascites. Compared with the non-severe PH group, portal venous velocity and intrahepatic transit time (ITT were significantly reduced in the severe PH group (all p<0.05. Difference between inspiratory and expiratory hepatic venous damping indices (ΔHVDI, hepatic venous arrival time (HVAT and ITT moderately correlated with HVPG (r = -0.358, -0.338, and -0.613, respectively. Areas under the curves for severe PH were 0.94 of ITT and 0.72 of HVAT, respectively (all p<0.05. ITT under 6 seconds indicated severe PH with a sensitivity of 92% and a specificity of 89%.Hepatic CEUS may be more useful in estimating the HVPG value and determining the presence of severe PH compared to DUS, and ITT was the most accurate parameter to diagnose severe PH.

  8. [Liver transplantation].

    Science.gov (United States)

    Pompili, Maurizio; Mirante, Vincenzo Giorgio; Rapaccini, Gian Ludovico; Gasbarrini, Giovanni

    2004-01-01

    Liver transplantation represents the first choice treatment for patients with fulminant acute hepatitis and for patients with chronic liver disease and advanced functional failure. Patients in the waiting list for liver transplantation are classified according to the severity of their clinical conditions (evaluated using staging systems mostly based on hematochemical parameters related to liver function). This classification, together with the blood group and the body size compatibility, remains the main criterion for organ allocation. The main indications for liver transplantation are cirrhosis (mainly HCV-, HBV- and alcohol-related) and hepatocellular carcinoma emerging in cirrhosis in adult patients, biliary atresia and some inborn errors of metabolism in pediatric patients. In adults the overall 5-year survival ranges between 60 and 70%, in both American and European series. Even better results have been reported for pediatric patients: in fact, the 5-year survival rate for children ranges between 70 and 80% in the main published series. In this study we evaluated the main medical problems correlated with liver transplantation such as immunosuppressive treatment, acute and chronic rejection, infectious complications, the recurrence of the liver disease leading to transplantation, and cardiovascular and metabolic complications.

  9. Quantitative PET of liver functions.

    Science.gov (United States)

    Keiding, Susanne; Sørensen, Michael; Frisch, Kim; Gormsen, Lars C; Munk, Ole Lajord

    2018-01-01

    Improved understanding of liver physiology and pathophysiology is urgently needed to assist the choice of new and upcoming therapeutic modalities for patients with liver diseases. In this review, we focus on functional PET of the liver: 1) Dynamic PET with 2-deoxy-2-[ 18 F]fluoro- D -galactose ( 18 F-FDGal) provides quantitative images of the hepatic metabolic clearance K met (mL blood/min/mL liver tissue) of regional and whole-liver hepatic metabolic function. Standard-uptake-value ( SUV ) from a static liver 18 F-FDGal PET/CT scan can replace K met and is currently used clinically. 2) Dynamic liver PET/CT in humans with 11 C-palmitate and with the conjugated bile acid tracer [ N -methyl- 11 C]cholylsarcosine ( 11 C-CSar) can distinguish between individual intrahepatic transport steps in hepatic lipid metabolism and in hepatic transport of bile acid from blood to bile, respectively, showing diagnostic potential for individual patients. 3) Standard compartment analysis of dynamic PET data can lead to physiological inconsistencies, such as a unidirectional hepatic clearance of tracer from blood ( K 1 ; mL blood/min/mL liver tissue) greater than the hepatic blood perfusion. We developed a new microvascular compartment model with more physiology, by including tracer uptake into the hepatocytes from the blood flowing through the sinusoids, backflux from hepatocytes into the sinusoidal blood, and re-uptake along the sinusoidal path. Dynamic PET data include information on liver physiology which cannot be extracted using a standard compartment model. In conclusion , SUV of non-invasive static PET with 18 F-FDGal provides a clinically useful measurement of regional and whole-liver hepatic metabolic function. Secondly, assessment of individual intrahepatic transport steps is a notable feature of dynamic liver PET.

  10. Quantitative PET of liver functions

    Science.gov (United States)

    Keiding, Susanne; Sørensen, Michael; Frisch, Kim; Gormsen, Lars C; Munk, Ole Lajord

    2018-01-01

    Improved understanding of liver physiology and pathophysiology is urgently needed to assist the choice of new and upcoming therapeutic modalities for patients with liver diseases. In this review, we focus on functional PET of the liver: 1) Dynamic PET with 2-deoxy-2-[18F]fluoro-D-galactose (18F-FDGal) provides quantitative images of the hepatic metabolic clearance K met (mL blood/min/mL liver tissue) of regional and whole-liver hepatic metabolic function. Standard-uptake-value (SUV) from a static liver 18F-FDGal PET/CT scan can replace K met and is currently used clinically. 2) Dynamic liver PET/CT in humans with 11C-palmitate and with the conjugated bile acid tracer [N-methyl-11C]cholylsarcosine (11C-CSar) can distinguish between individual intrahepatic transport steps in hepatic lipid metabolism and in hepatic transport of bile acid from blood to bile, respectively, showing diagnostic potential for individual patients. 3) Standard compartment analysis of dynamic PET data can lead to physiological inconsistencies, such as a unidirectional hepatic clearance of tracer from blood (K 1; mL blood/min/mL liver tissue) greater than the hepatic blood perfusion. We developed a new microvascular compartment model with more physiology, by including tracer uptake into the hepatocytes from the blood flowing through the sinusoids, backflux from hepatocytes into the sinusoidal blood, and re-uptake along the sinusoidal path. Dynamic PET data include information on liver physiology which cannot be extracted using a standard compartment model. In conclusion, SUV of non-invasive static PET with 18F-FDGal provides a clinically useful measurement of regional and whole-liver hepatic metabolic function. Secondly, assessment of individual intrahepatic transport steps is a notable feature of dynamic liver PET. PMID:29755841

  11. Sonographic pattern of focal nodular hyperplasia of the liver

    International Nuclear Information System (INIS)

    Majewski, A.; Gratz, K.F.; Broelsch, C.; Gebel, M.

    1984-01-01

    Focal nodular hyperplasia of the liver (FNH) is a histologically defined benign hepatic tumour, possibly associated with the use of oral contraceptives. The present study deals with the question whether FNH can be distinguished from other lesions of the liver by ultrasonography alone or by a combination of realtime sonography and radiologic procedures. Therefore 18 cases of FNH, 16 females and 2 males, are presented. We retrospectively reviewed the diagnostic results of real-time sonography, hepatic scintigraphy, computed tomography with dynamic CT-densitometry, and angiography on these 18 patients. Ultrasonography enables the identification of the lesion in all of the 18 cases. FNH appears to show varying degrees of echogenicity (slight hypoechoic in 6 cases, isoechoic in 6 cases, and slight hyperechoic in 4 cases). In most of the patients the tumour had similar acoustic characteristics at the surrounding normal liver. By ultrasonography alone there is no possible differentation of FNH from other hepatic tumours. Both the echo pattern of FNH and the results of the ultrasonically guided cytopuncture are unspecific. (orig.)

  12. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    Science.gov (United States)

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  13. Chronic Liver Disease : Value of Sonographic Study of the Liver Surface

    International Nuclear Information System (INIS)

    Chung, Jae Joon; Kim, Myeong Jin; Han, Kwang Hyub; Chon, Chae Yoon; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang

    1995-01-01

    To evaluate the diagnostic value of sonographic irregularities of liver surface in the differentiation of chronic liver disease. Fifty-eight patients with either chronic hepatitis or early stage of liver cirrhosis were examined with 5 MHz linear array transducer by observing the liver surface.We compared the sonographic findings with peritoneoscopic and pathologic findings. Thirty-five patients with smooth surface showed variable pathological results, including chronic active and persistent hepatitis, inactive hepatitis and alcoholic hepatitis without any evidence of cirrhosis. Nineteen patients with micronodules mostly revealed chronic active hepatitis and cirrhosis. All 4 patients with macronodules were proved pathologically ascirrhosis. High resolution ultrasonography(HRUS) showed smooth liver surface in 35 patients(60.3%),micronodular surface in l9(32.8%), and macronodular surface in 4 (6.9%). Twenty-one cases(60.0%) among 35 patients with smooth surface were peritoneoscopically normal and 12 cases(34.3%) showed dimpling surface. However among l9 patients with micronodular surface, only 5 cases(26.3%) showed micronodular surface on peritoneoscopy. while 8 cases(42.l%) showed nracronodular surface and 6 cases(3l.6%) dimpling surface. All 4 patients with macronodulesrevealed peritoneoscopically nracronodular surface. Observation of liver surface by HRUS was useful in predicting the progression of chronic hepatitis to cirrhosis. However, it was not helpful in the differentiation between normal liver and chronic hepatrtrs

  14. Is pneumoperitoneum the terra ignota in ultrasonography?

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2015-06-01

    Full Text Available In most cases, pneumoperitoneum is caused by gastrointestinal perforation, which usually requires surgical treatment. Many authors believe that ultrasound imaging of pneumoperitoneum is at least as effective as conventional radiography, or even that its efficacy is superior. In such a situation, it is imperative to make this modality one of the main tools in the diagnostic arsenal of emergency medicine. This is the main aim of this paper. First, ultrasound anatomy of so-called thoracic-abdominal border is discussed. The equipment requirements emphasize that the diagnostic process can be conducted with the simplest portable US scanner, even without the Doppler mode. The technique of a US examination, the aim of which is to detect, free air in the peritoneal cavity is also simple and conducted with the patients lying down, either in the supine or lateral position. A convex transducer with the frequency of 3.5–5 MHz is applied above the lower intercostal spaces on the right and left side, to the epigastric region below the xiphoid process and in various sites of the abdominal wall. The most effective examination, however, is conducted in the left lateral position via the right intercostal spaces. The differential diagnosis on the right side under the diaphragm should include the presence of a subdiaphragmatic abscess with gas and a hepatic abscess with a similar content as well as transposition of the colon in between the diaphragm and the liver (Chilaiditi syndrome. It seems that the inclusion of a US examination to the E-FAST method in order to detect free gas in the peritoneal cavity is justified since it is a sign of gastrointestinal perforation in numerous cases, and is clinically as relevant as the presence of free fluid.

  15. Nanoparticles for the treatment of liver fibrosis

    Directory of Open Access Journals (Sweden)

    Poilil Surendran S

    2017-09-01

    Full Text Available Suchithra Poilil Surendran, Reju George Thomas, Myeong Ju Moon, Yong Yeon Jeong Department of Radiology, BioMolecular Theranostics (BiT Lab, Chonnam National University Medical School, Chonnam National University Hwasun Hospital (CNUHH, South Korea Abstract: Chronic liver diseases represent a global health problem due to their high prevalence worldwide and the limited available curative treatment options. They can result from various causes, both infectious and noninfectious diseases. The application of nanoparticle (NP systems has emerged as a rapidly evolving area of interest for the safe delivery of various drugs and nucleic acids for chronic liver diseases. This review presents the pathogenesis, diagnosis and the emerging nanoparticulate systems used in the treatment of chronic liver diseases caused by liver fibrosis. Activated hepatic stellate cell (HSC is considered to be the main mechanism for liver fibrosis. Ultrasonography and magnetic resonance imaging techniques are widely used noninvasive diagnostic methods for hepatic fibrosis. A variety of nanoparticulate systems are mainly focused on targeting HSC in the treatment of hepatic fibrosis. As early liver fibrosis is reversible by current NP therapy, it is being studied in preclinical as well as clinical trials. Among various nanoparticulate systems, inorganic NPs, liposomes and nanomicelles have been widely studied due to their distinct properties to deliver drugs as well as other therapeutic moieties. Liposomal NPs in clinical trials is considered to be a milestone in the treatment of hepatic fibrosis. Currently, NP therapy for liver fibrosis is updating fast, and hopefully, it can be the future remedy for liver fibrosis. Keywords: liver fibrosis, inorganic nanoparticles, liposomes, micelles

  16. Experimental study on ablating goat liver tissue with ultrasound imaging guided percutaneous irreversible electroporation

    Directory of Open Access Journals (Sweden)

    Ying LIU

    2011-03-01

    Full Text Available Objective To investigate the proper method of percutaneous irreversible electroporation(IRE to ablate goat liver tissue under ultrasonic guidance,and observe the features of ultrasound imaging and histological changes.Methods The pulse electric fields(PEFs with permanent duration(100 μs,frequency(1Hz,voltage(2000V and pulses(120 pieces were applied to the electrodes,and the electrodes were placed into goats’ liver under ultrasound guidance through the animal skin to the target area.The treated area was observed by real-time ultrasound scanning,and the histopathological changes were assessed by hematoxylin and eosin(HE staining under light microscope at the time of 0h and 24h after IRE ablation.The circumscribed ablated area was compared with that of finite element modeling(FEM calculation method.Results Ultrasound imaging guidance was accurate in focusing on the target area.Imaging captured by the ultrasound after IRE procedure was quite different from that of the normal liver imaging.Complete hepatic cell death with a sharp demarcation between the ablated zone and the non-ablated zone was well visualized 24 hours after the procedure.Necrospy-based measurement demonstrated a high consistence with FEM-anticipated ablation zones.Conclusion With real-time monitoring by ultrasonography and well-controlled ablation of the target tissue,percutaneous IRE can provide a novel and unique ablative method for cancer treatment.The present paper provides a fundamental experimental work for future studies on clinical application of IRE.

  17. Acute Liver Failure Due to Regorafenib May Be Caused by Impaired Liver Blood Flow: A Case Report.

    Science.gov (United States)

    Akamine, Takaki; Ando, Koji; Oki, Eiji; Saeki, Hiroshi; Nakashima, Yuichiro; Imamura, Y U; Ohgaki, Kippei; Maehara, Yoshihiko

    2015-07-01

    Regorafenib has been approved for treatment of patients with unresectable or recurrent gastrointestinal stromal tumors resistant to imatinib or sunitinib. However, regorafenib has severe side-effects, including acute liver failure. We describe the case of a patient with multiple liver metastases of a small intestinal stromal tumor who experienced acute liver failure while being treated with regorafenib. A 50-year-old patient with an unresectable small intestinal stromal tumor resistant to prior treatment with imatinib and sunitinib was started on regorafenib, but experienced acute liver failure 10 days later. Plasma exchange and steroid pulse treatment improved her liver function. During liver failure, abdominal ultrasonography showed to-and-fro flow in the portal vein. Lactate dehydrogenase concentration was markedly elevated to 1633 U/l. These findings indicate that liver failure in this patient was due to impaired liver blood flow. Regorafenib may impair liver blood flow, inducing acute liver failure. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  18. Benign Liver Tumors

    Science.gov (United States)

    ... Liver Function Tests Clinical Trials Liver Transplant FAQs Medical Terminology Diseases of the Liver Alagille Syndrome Alcohol-Related ... the Liver The Progression of Liver Disease FAQs Medical Terminology HOW YOU CAN HELP Sponsorship Ways to Give ...

  19. Liver Function Tests

    Science.gov (United States)

    ... Liver Function Tests Clinical Trials Liver Transplant FAQs Medical Terminology Diseases of the Liver Alagille Syndrome Alcohol-Related ... the Liver The Progression of Liver Disease FAQs Medical Terminology HOW YOU CAN HELP Sponsorship Ways to Give ...

  20. Progression of Liver Disease

    Science.gov (United States)

    ... Liver Function Tests Clinical Trials Liver Transplant FAQs Medical Terminology Diseases of the Liver Alagille Syndrome Alcohol-Related ... the Liver The Progression of Liver Disease FAQs Medical Terminology HOW YOU CAN HELP Sponsorship Ways to Give ...

  1. Liver (Hepatocellular) Cancer Screening

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Liver (Hepatocellular) Cancer Screening (PDQ®)–Patient Version What is ... These are called diagnostic tests . General Information About Liver (Hepatocellular) Cancer Key Points Liver cancer is a ...

  2. Aspectos morfológicos da ultra-sonografia hepática de ovinos Morphologic aspects of hepatic ultrasonography in sheep

    Directory of Open Access Journals (Sweden)

    Pedro B. Néspoli

    2009-04-01

    normal liver limits in ultrasonographic examination. In this study 58 Santa Inês sheep breed were used and divided in 3 groups: n1=8 males, n2=10 not pregnant females and n3=40 pregnant females. The animals were scanned from the 12º to 8º intercostal spaces (EI to observe the localization of the vena cava caudal (VC, gallbladder (VB and to measure the liver thickness above the VC and vena portae VP under the 11º and 10º EI. The liver was examined on satisfactory way from the 12º till the 8º EI. Both the VC and the VP where observed from the 12º to 9º EI, however the VC could not be observed in 11 animals, 10 of them were over 50 kg. Between the two female groups the VC and VP where observed most frequently from the 11º to 10º EI and in all males examined from the 12º to 10º EI. The location of the gallbladder varies between the 10º to the 8º EI, with bigger incidence between the 9º and the 8º EI in pregnant and no pregnant females groups and underneath the 9º EI on the male group. Comparatively, the ecogenicity of the liver parenchyma was more intense than kidney cortex. There was a significant correlation between liver's weight and hepatic thikness above the vena portae on the 11º and 10º EI on the pregnant females group. The US supplied to important information about the topography and echogenicity of the liver and showed to be a useful tool to esteem the liver's weight.

  3. Abdominal Subcutaneous Fat Thickness Measured by Ultrasonography Correlates with Hyperlipidemia and Steatohepatitis in Obese Children.

    Science.gov (United States)

    Lee, Sung Hyun; Kim, Dongwan; Baek, Min Young; Tchah, Hann; Kim, Yeon Sun; Ryoo, Eell; Kim, Yun Mi

    2015-06-01

    The aim of this study is to evaluate the relationship between abdominal subcutaneous fat thickness measured by ultrasonography (US) and serum lipid profile and liver transaminases in obese children. One hundred and sixty-six children diagnosed with obesity from May 2001 to December 2013 were included in this study. Data on serum lipid profile and liver transaminases were collected from clinical records. Abdominal subcutaneous fat thickness and grade of hepatic steatosis were evaluated by US. Of the 166 children, 107 were diagnosed with hepatic steatosis by US, 46 with grade I, 56 with grade II, and five children with grade III. According to the grade of hepatic steasosis, the average values of midline abdominal subcutaneous fat thickness and right flank abdominal subcutaneous fat thickness measured 2.9±0.8 cm and 1.9±0.7 cm in the normal group, 3.3±0.8 cm and 2.0±0.7 cm in grade I, 3.8±0.8 cm and 2.3±0.8 cm in grade II, and 4.1±0.8 cm and 2.8±1.4 cm in grade III, respectively. Abdominal subcutaneous fat thickness correlated with grade of hepatic steatosis (pabdominal subcutaneous fat thickness correlated with concentration of serum lipids and liver transaminases in the age group of 12-14 years (pAbdominal subcutaneous fat thickness measured by US can be used as a reliable predictor of possible hyperlipidemia and steatohepatitis in children, especially during the adolescent stage.

  4. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    Directory of Open Access Journals (Sweden)

    Size Wu

    2016-01-01

    Full Text Available Purpose: The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. Methods: A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. Results: The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501 and 94.2% (389/413, respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177 vs. liver without fat infiltration (389/413 (P=0.277; mild fatty liver (162/177 vs. moderate fatty liver (190/212 (P=0.604; mild fatty liver (162/177 vs. severe fatty liver (83/112 (P<0.001; moderate fatty liver (190/212 vs. liver without fat infiltration (389/413 (P=0.051; moderate fatty liver (190/212 vs. severe fatty liver (83/112 (P<0.001; severe fatty liver (83/112 vs. liver without fat infiltration (389/413 (P<0.001; and fatty liver (435/501 vs. liver without fat infiltration (389/413 (P<0.001. Conclusion: Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis.

  5. Clinical significance of segmental parenchymal excretion delay on Tc-99m DISIDA hepatobiliary scan

    International Nuclear Information System (INIS)

    Kang, D. Y.; Ryu, J. S.; Moon, D. H.; Lee, S. K.; Kim, M. H.; Lee, H. K.

    1998-01-01

    Segmental parenchymal excretion delay on Tc-99m DISIDA scan in caused by intrahepatic bile duct obstruction. However, the diagnostic value for intrahepatic bile duct obstruction is unknown. We conducted this study to assess the positive predictive value of segmental excretion delay for the diagnosis of intrahepatic bile duct obstruction, and additional benefit over other noninvasive radiologic studies. The study population consisted of 43 patients (48 scans) who showed segmental parenchymal excretion delay on Tc-99m DISIDA scan. The results of abdominal CT or ultrasonography, which was done within 1 month of Tc-99m DISIDA scan, were compared with scintigraphic findings. The etiology of segmental parenchymal excretion delay was determined by ERC or PTC in 31 scans, and follow-up studies in 13 scans. No causes were identified in 4 scans. The positive predictive value of segmental parenchymal excretion delay for intrahepatic bile duct obstruction was 92% (44/48). On the other hand, 13% (5/38) of CT and 28% (5/18) of ultrasonography were normal. In 18% *7/38) of CT and 17% (3/18) of ultrasonography, only intrahepatic bile duct dilatation was noted without any diagnostic findings of intrahepatic bile duct obstruction. Segmental parenchymal excretion delay on Tc-99m DISIDA scan had a high positive predictive value for the diagnosis of intrahepatic bile duct obstruction. Tc-99m DISIDA scan may be useful for the diagnosis of intrahepatic bile duct obstruction, especially in patients with nondiagnostic CT or ultrasonography. The diagnostic usefulness need to be confirmed by further prospective studies

  6. Role of cervical ultrasonography in primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Shaheen, Feroze; Chowdry, Nisar; Gojwari, Tariq; Wani, Arshad Iqbal; Khan, Showkat

    2008-01-01

    To evaluate the role of USG in the preoperative localization of parathyroid adenomas in patients with symptomatic hyperparathyroidism and to compare its usefulness with that of scintigraphy scan and postoperative findings. Twenty-five patients with symptomatic primary hyperparathyroidism were subjected to USG of the neck and nuclear scintigraphy, followed by surgery. The results were independently analyzed and compared with per-operative findings. The 25 patients had a total of 28 abnormal glands: 22 solitary adenomas, and 6 multiple adenomas (two each in three patients). USG detected 20 out of 22 solitary adenomas and three out of six multiple adenomas. USG missed five abnormal glands, two of which were in the neck and three in the mediastinum. Scintigraphy was positive in 26 abnormal glands, out of which 22 were single and four were multiple. Two abnormal glands were missed: one in the neck and one in the mediastinum. As limited neck dissection for primary hyperparathyroidism becomes increasingly popular, USG has been found to be a sensitive, specific, and easily available noninvasive investigation for parathyroid localization. It can be easily offered to patients as a method for preoperative localization prior to limited parathyroid surgery outside tertiary care settings

  7. Ultrasonography in the diagnosis of traumatic hemothorax

    International Nuclear Information System (INIS)

    Hilendarov, A.; Nedeva-Petkova, M.; Simova, E.; Semova, R.; Georgieva, M.; Alexieva, D.

    2006-01-01

    Full text: The possibilities and advantages of US tomography in the diagnosis and follow-up of traumatic hemothorax in major trauma patients were presented. US examinations of the chest in conditions of emergency with purpose to identify hemothorax were performed in 56 (41 male and 15 female patients for a period of two years.US machine 'Siemens-Adara' supplied with 3.5 and 7 MHz linear and convex transducers was used. The right and left intercostal oblique view was used for US examination to identify free pleural fluid. Tube thoracotomy and/or a CT scan of the chest were used as the criterion standard for positive findings of hemothorax among the studied patients. In 49 (87.5%) of all 56 major trauma patients was achieved true-positive diagnostic result of hemothorax confirmed in 39 cases post operatively and in 10 after investigation by CT. In 6 (10.71%) patients - true-negative and in 1 (1.7%) false negative results were obtained. Our experience demonstrated that US is a sensitive, specific, and accurate diagnostic method in detecting traumatic hemothorax. The advantages of US tomography in the diagnosis of traumatic hemothorax are: First - the examination is not influenced by the position of the patient: Second - the rapidity of examination is 2-4 min and simultaneously differentiation of dense regions. Third - the possibility to present small amount of liquid collections 20-30 cc

  8. Enlarged Liver

    Science.gov (United States)

    ... of liver damage. Medicinal herbs. Certain herbs, including comfrey, ma huang and mistletoe, can increase your risk ... herbs to avoid include germander, chaparral, senna, mistletoe, comfrey, ma huang, valerian root, kava, celandine and green ...

  9. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  10. Screening for fetal growth restriction with universal third trimester ultrasonography in nulliparous women in the Pregnancy Outcome Prediction (POP) study: a prospective cohort study.

    Science.gov (United States)

    Sovio, Ulla; White, Ian R; Dacey, Alison; Pasupathy, Dharmintra; Smith, Gordon C S

    2015-11-21

    Fetal growth restriction is a major determinant of adverse perinatal outcome. Screening procedures for fetal growth restriction need to identify small babies and then differentiate between those that are healthy and those that are pathologically small. We sought to determine the diagnostic effectiveness of universal ultrasonic fetal biometry in the third trimester as a screening test for small-for-gestational-age (SGA) infants, and whether the risk of morbidity associated with being small differed in the presence or absence of ultrasonic markers of fetal growth restriction. The Pregnancy Outcome Prediction (POP) study was a prospective cohort study of nulliparous women with a viable singleton pregnancy at the time of the dating ultrasound scan. Women participating had clinically indicated ultrasonography in the third trimester as per routine clinical care and these results were reported as usual (selective ultrasonography). Additionally, all participants had research ultrasonography, including fetal biometry at 28 and 36 weeks' gestational age. These results were not made available to participants or treating clinicians (universal ultrasonography). We regarded SGA as a birthweight of less than the 10th percentile for gestational age and screen positive for SGA an ultrasonographic estimated fetal weight of less than the 10th percentile for gestational age. Markers of fetal growth restriction included biometric ratios, utero-placental Doppler, and fetal growth velocity. We assessed outcomes for consenting participants who attended research scans and had a livebirth at the Rosie Hospital (Cambridge, UK) after the 28 weeks' research scan. Between Jan 14, 2008, and July 31, 2012, 4512 women provided written informed consent of whom 3977 (88%) were eligible for analysis. Sensitivity for detection of SGA infants was 20% (95% CI 15-24; 69 of 352 fetuses) for selective ultrasonography and 57% (51-62; 199 of 352 fetuses) for universal ultrasonography (relative sensitivity 2

  11. Interesting bone scans - unusual findings

    International Nuclear Information System (INIS)

    Dobson, M.; Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.

    1997-01-01

    A 59-year-old female with carcinoma of the colon and known liver metastatic disease was referred for bone scan to evaluate for bone metastases. Although no bone metastases were found, there was abnormal uptake noted in the liver corresponding to a metastatic calcified lesion. The only other findings were of degenerative disease in the cervical spine, right shoulder and small joints of the hands. A 69-year-old male with carcinoma of the prostate and right side low back pain was referred for bone scan. No focal abnormalities to suggest metastatic disease were identified; findings within the cervical spine, lumber spine and knees were presumed secondary to degenerative disease. Intermittent pain persisted and the patient was referred for a repeat bone scan six months later. Previous scan findings of degenerative disease and no metastatic disease were confirmed; however, closer inspection revealed an enlarged right kidney with significant retention of tracer in the pelvicalyceal system suggesting possible obstruction. A Retrograde pyelogram was performed, and no obvious obstruction demonstrated. As bone scan findings were very suggestive of obstruction, a DTPA scan with lasix was performed showing a dilated right collecting system with no functional obstruction. Given the degree of dilation, it is possible that the patient experiences intermittent PUJ obstruction causing his symptoms. A 33-year-old male with insulin dependent diabetes mellitus and viral arthritis was referred for a bone scan. A three phase revealed increased uptake in the region of the knee and leR proximal tibia. Delayed whole body images revealed multiple focal areas of osteoblastic activity in the leR tibia. Abnormal uptake was also seen in the upper third of the leR femur. The remainder of the skeletal survey was normal. X-ray correlation of the leR tibia and femoral findings was undertaken. Combinating unilateral changes on bone scan and X-ray although very suggestive of sclerotic polyostotic

  12. Radiation-induced liver damage

    International Nuclear Information System (INIS)

    Marcial, V.A.; Santiago-Delpin, E.A.; Lanaro, A.E.; Castro-Vita, H.; Arroyo, G.; Moscol, J.A.; Gomez, C.; Velazquez, J.; Prado, K.

    1977-01-01

    Due to the recent increase in the use of radiation therapy in the treatment of cancer with or without chemotherapy, the risk of liver radiation damage has become a significant concern for the radiotherapist when the treated tumour is located in the upper abdomen or lower thorax. Clinically evident radiation liver damage may result in significant mortality, but at times patients recover without sequelae. The dose of 3000 rads in 3 weeks to the entire liver with 5 fractions per week of 200 rads each, seems to be tolerated well clinically by adult humans. Lower doses may lead to damage when used in children, when chemotherapy is added, as in recent hepatectomy cases, and in the presence of pre-existent liver damage. Reduced fractionation may lead to increased damage. Increased fractionation, limitation of the dose delivered to the entire liver, and restriction of the high dose irradiation volume may afford protection. With the aim of studying the problems of hepatic radiation injury in humans, a project of liver irradiation in the dog is being conducted. Mongrel dogs are being conditioned, submitted to pre-irradiation studies (haemogram, blood chemistry, liver scan and biopsy), irradiated under conditions resembling human cancer therapy, and submitted to post-irradiation evaluation of the liver. Twenty-two dogs have been entered in the study but only four qualify for the evaluation of all the study parameters. It has been found that dogs are susceptible to liver irradiation damage similar to humans. The initial mortality has been high mainly due to non-radiation factors which are being kept under control at the present phase of the study. After the initial experiences, the study will involve variations in total dose and fractionation, and the addition of anticoagulant therapy for possible prevention of radiation liver injury. (author)

  13. Evidence and recommendations for imaging liver fat in children, based on systematic review.

    Science.gov (United States)

    Awai, Hannah I; Newton, Kimberly P; Sirlin, Claude B; Behling, Cynthia; Schwimmer, Jeffrey B

    2014-05-01

    Fatty liver is a common problem in children and increases their risk for cirrhosis, diabetes, and cardiovascular disease. Liver biopsy is the clinical standard for diagnosing and grading fatty liver. However, noninvasive imaging modalities are needed to assess liver fat in children. We performed a systematic review of studies that evaluated imaging liver fat in children. We searched PubMed for original research articles in peer-reviewed journals from January 1, 1982, through December 31, 2012, using the key words "imaging liver fat." Studies included those in English, and those performed in children from birth to 18 years of age. To be eligible for inclusion, studies were required to measure hepatic steatosis via an imaging modality and a quantitative comparator as the reference standard. We analyzed 9 studies comprising 610 children; 4 studies assessed ultrasonography and 5 studies assessed magnetic resonance imaging (MRI). Ultrasonography was used in the diagnosis of fatty liver with positive predictive values of 47% to 62%. There was not a consistent relationship between ultrasound steatosis score and the reference measurement of hepatic steatosis. Liver fat as measurements by MRI or by spectroscopy varied with the methodologies used. Liver fat measurements by MRI correlated with results from histologic analyses, but sample size did not allow for an assessment of diagnostic accuracy. Available evidence does not support the use of ultrasonography for the diagnosis or grading of fatty liver in children. Although MRI is a promising approach, the data are insufficient to make evidence-based recommendations regarding its use in children for the assessment of hepatic steatosis. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.

  14. Role of ultrasonography in the ocular and the orbital diseases

    International Nuclear Information System (INIS)

    Kim, S. R.; Kim, K. S.; Lee, Y. C.; Park, S. S.

    1984-01-01

    With conventional methods including orbital arteriography, orbital venography, penumoobitography and positive contrast orbitography, imaging of eyeball and orbit is not only difficult, invasive or expensive but also nonspecific in result. Ultrasonography provides safe, specific and reliable way to obtain image of eyeball and orbit. Fifty six ultrasonograms of 50 patients which were referred under the impression of various ophthalmic diseases were analyzed. 1. Sixteen cases were normal. 2. Ocular diseases were 26 cases and extraocular orbital diseases were 8 cases. 3. Among the ocular diseases, 9 foreign body cases, 6 retinal detachment cases, 5 vitreous hemorrhage 4. Among the extraocular orbital diseases, 6 pseudotumor cases, 1 pseudolymphoma, 1 eyelid cyst case were diagnosed. 5. Ultrasonic findings were specific enough to differentiated from diseases and well corresponded with clinical and pathological diagnosis. 6. It can be concluded that ultrasonography is one of the most reliable imaging method in ocular and extraocular orbital diseases

  15. Potentialities of computed tomography and ultrasonography in colonic cancer

    International Nuclear Information System (INIS)

    Gorshkov, A.N.

    2001-01-01

    Data of examination of 59 patients with colonic cancer were used to consider the potentialities of transabdominal, transrectal ultrasonography and X-ay compound tomography and to assess their value in diagnosing colonic cancer, including its minor forms. Ultrasound and computed tomographic semiotics of colonic cancer and determines a place of the above techniques in the algorithm of radiation and instrumental studies are described. Inclusion of these techniques into the diagnostic algorithm may solve a range of differentially diagnostic problems and allows a preliminary analysis to be made in a tumor lesion according to the International TNM classification. Ultrasonography and X-ray computed tomography should be included into a range of basic methods for diagnosis of colonic cancer [ru

  16. Ultrasonography of Midline Scalp Masses : A Preliminary Report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyo Kyeong; Lee, Ho Kyu; Choi, Choong Gon; Kim, Kyeong Sook; Jung, Seung Mun; Suh, Dae Chul [Asan Medical Center University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    We report our ultrasonographic experiences in the evaluation of small midline scalp masses. Ultrasonography was performed in four patients with midline scalp mass less than 3cm and its connecting tract into the cranialcavity. Ultrasonographic findings were correlated with pathologic results. There were three cephaloceles and one cystic lymph angioma. Two encephalomenin-goceles, located in occipital region, were mixed cystic and solid lesions and one atretic meningocele in parietal region was a solid lesion. Ultrasonogram of all three cases showed calvarial defect and connecting tract into the cranial cavity. On the contrary, a cystic lymph angioma in occipital region was a purely cystic mass without an associated calvarial defect. We suppose that ultrasonography could be a useful screening tool in the evaluation of midline scalp masses

  17. Transrectal ultrasonography of anorectal disease: advantages and disadvantages

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Ju [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    Transrectal ultrasonography (TRUS) has been widely accepted as a popular imaging modality for Epub ahead of print evaluating the lower rectum, anal sphincters, and pelvic floor in patients with various anorectal diseases. It provides excellent visualization of the layers of the rectal wall and of the anatomy of the anal canal. TRUS is an accurate tool for the staging of primary rectal cancer, especially for early stages. Although magnetic resonance imaging is a modality complementary to TRUS with advantages for evaluating the mesorectum, external sphincter, and deep pelvic inflammation, three-dimensional ultrasonography improves the detection and characterization of perianal fistulas and therefore plays a crucial role in optimal treatment planning. The operator should be familiar with the anatomy of the rectum and pelvic structures relevant to the preoperative evaluation of rectal cancer and other anal canal diseases, and should have technical proficiency in the use of TRUS combined with an awareness of its limitations compared to magnetic resonance imaging.

  18. Henoch-Schonlein purpura: ultrasonography of scrotal and penile involvement

    Directory of Open Access Journals (Sweden)

    Youngsik Lim

    2015-04-01

    Full Text Available Testicular or scrotal involvement has been reported in children with Henoch-Schonlein purpura (HSP, but there are very few reports on penile involvement. We report the initial and follow-up ultrasonographic findings of scrotal and penile involvement of HSP in a 5-year-old boy. On ultrasonography, scrotal soft tissue thickening and epididymal swelling with increased vascularity were noted, and on the penis, a focal mass-like lesion appeared on the dorsal surface of the distal penis, having a hypoechoic mass-like appearance without visible vascular flow on a Doppler study. After 2 days of treatment, follow-up ultrasonography showed normal scrotum and penis with a resolved soft tissue mass-like lesion. Therefore, we think that HSP ultrasonographic findings involving the scrotum and penis might help to diagnose scrotal and penile involvement in a case of HSP and to avoid unnecessary medication and/or surgical procedures.

  19. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    Science.gov (United States)

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  20. Interfraction Liver Shape Variability and Impact on GTV Position During Liver Stereotactic Radiotherapy Using Abdominal Compression

    International Nuclear Information System (INIS)

    Eccles, Cynthia L.; Dawson, Laura A.; Moseley, Joanne L.; Brock, Kristy K.

    2011-01-01

    Purpose: For patients receiving liver stereotactic body radiotherapy (SBRT), abdominal compression can reduce organ motion, and daily image guidance can reduce setup error. The reproducibility of liver shape under compression may impact treatment delivery accuracy. The purpose of this study was to measure the interfractional variability in liver shape under compression, after best-fit rigid liver-to-liver registration from kilovoltage (kV) cone beam computed tomography (CBCT) scans to planning computed tomography (CT) scans and its impact on gross tumor volume (GTV) position. Methods and Materials: Evaluable patients were treated in a Research Ethics Board-approved SBRT six-fraction study with abdominal compression. Kilovoltage CBCT scans were acquired before treatment and reconstructed as respiratory sorted CBCT scans offline. Manual rigid liver-to-liver registrations were performed from exhale-phase CBCT scans to exhale planning CT scans. Each CBCT liver was contoured, exported, and compared with the planning CT scan for spatial differences, by use of in house-developed finite-element model-based deformable registration (MORFEUS). Results: We evaluated 83 CBCT scans from 16 patients with 30 GTVs. The mean volume of liver that deformed by greater than 3 mm was 21.7%. Excluding 1 outlier, the maximum volume that deformed by greater than 3 mm was 36.3% in a single patient. Over all patients, the absolute maximum deformations in the left-right (LR), anterior-posterior (AP), and superior-inferior directions were 10.5 mm (SD, 2.2), 12.9 mm (SD, 3.6), and 5.6 mm (SD, 2.7), respectively. The absolute mean predicted impact of liver volume displacements on GTV by use of center of mass displacements was 0.09 mm (SD, 0.13), 0.13 mm (SD, 0.18), and 0.08 mm (SD, 0.07) in the left-right, anterior-posterior, and superior-inferior directions, respectively. Conclusions: Interfraction liver deformations in patients undergoing SBRT under abdominal compression after rigid liver-to-liver

  1. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  2. Comparison of ultrasonography and radiography in diagnosis of rib fractures

    OpenAIRE

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-01-01

    Purpose: Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. Methods: In this cross-s...

  3. Comparison of immersion ultrasonography, ultrasound biomicroscopy and anterior segment optical coherence tomography in the evaluation of traumatic phacoceles

    Directory of Open Access Journals (Sweden)

    Harikrishna Vodapalli

    2012-01-01

    Full Text Available Blunt ocular trauma in the elderly can result in anterior dislocation of the crystalline lens into the subconjunctival space (phacocele. Although rare, this presentation can be missed, especially if the patient presents several days after the injury and if the lid is not everted on examination. While a careful clinical examination is adequate in the diagnosis, imaging techniques can be put to use for the accurate location of the associated sclera rupture. We report three cases of post-traumatic phacocele wherein ultrasound biomicroscopy (UBM was compared to the anterior segment optical coherence tomography (AS-OCT and B-scan ultrasonography (B-scan, in order to establish the best imaging tool for this condition. We concluded, based on image quality, that UBM could be the imaging modality of choice to aid in the diagnosis of phacocele.

  4. Role of ultrasonography in the evaluation of children with acute abdomen in the emergency set-up

    Directory of Open Access Journals (Sweden)

    Aviral

    2005-01-01

    Full Text Available Background: Acute abdomen in children has been aptly described as Pandora′s box. Unlike computerized tomography (CT scan, ultrasonography (USG has no radiation hazard and the present study analyses the diagnostic yield of the USG in acute abdomen in children. Materials and Methods: Between September 2001 to October 2003, 75 patients with acute abdomen underwent clinical examination, routine biochemical tests, erect X-ray abdomen, USG and CT scan. Laparotomy and histological examination established final diagnosis. Results: The accuracy of correct diagnosis was 60%, 66.6%, 64%, 98.7% with clinical examination alone, USG alone, clinical examination combined with conventional radiography, and clinical evaluation combined with conventional radiography and USG respectively. USG helped to prevent unnecessary laparotomy in 16.3% of patients. Conclusions: USG is good investigative modality in the management of acute abdomen in children.

  5. Urinary tract infection in children: Role of ultrasonography

    International Nuclear Information System (INIS)

    Lee, Hye Won; Lee, Sun Wha; Ko, Young Tae; Lim, Joo Won

    1994-01-01

    To evaluate diagnostic usefulness of ultrasonography(US) in pediatric patient with urinary tract infection. Fifty-five children with urinary tract infection underwent renal ultrasonography and voiding cystourethrography(VCUG). The imaging findings were analyzed retrospectively. Renal sonograms were normal in 34 of 55 children(62%). Five of 34 patients with normal sonogram had vesicoureteral reflux of grade I and III on VCUG. Renal sonograms were abnormal in 21 of 55 children(38%). Sonographic findings included hydronephrosis, hyperechoic kidney, nephromegaly, altrophic kidney, renal abscess, and duplex ureter. Eleven of 21 patient with abnormal sonogram had vesicoureteral reflux of grade I to IV on VCUG. Ultrasonography is an useful and reliable initial screening examination in the investigation of children with UTI. Unfortunately US is neither sufficiently sensitive nor specific for detecting VUR. VCUG provides confirmative and valuable information about vesicoureteral reflux, and VCUG should be considered as a next modality for UTI. The combined use of sonography and VCUG provides more valuable information in urinary tract infection

  6. Ultrasonography of the equine shoulder: technique and normal appearance.

    Science.gov (United States)

    Tnibar, M A; Auer, J A; Bakkali, S

    1999-01-01

    This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted spin-echo sequence. Ultrasonography images were compared to frozen specimens and MRI images to correlate the ultrasonographic findings to the gross anatomy of the shoulder. Ultrasonography allowed easy evaluation of the biceps brachii and the infraspinatus tendon and their bursae, the supraspinatus muscle and tendons, the superficial muscles of the shoulder, and the underlying humerus and scapula. Only the lateral and, partially, the caudal aspects of the humeral head could be visualized with ultrasound. Ultrasonographic appearance, orientation, and anatomic relationships of these structures are described. Ultrasonographic findings correlated well with MRI images and with gross anatomy in the cadavers' limbs.

  7. Evaluation of arterial embolization in treating hyperthyroidism by colour ultrasonography

    International Nuclear Information System (INIS)

    Sun Xiuying; Yang Jijin; Chen Ningning; Gu Limin; Wang Ying; Chen Jianquan

    2003-01-01

    Objective: To assess the effect of arterial embolization in treating hyperthyroidism by colour ultrasonography. Methods: Forty two cases of hyperthyroidism were treated with thyroid-arteries embolization. A few days before and 1, 3, 6 months after embolization, the echograms of thyroids were observed including the volumes of thyroids and the internal diameters of thyroid-arteries were measured with colour ultrasonography respectively. The Vs, Vd, Vm, PI, RI were measured with the Doppler and the quantities of blood flow were calculated. The relationships of changes for all these parameters and T 3 , T 4 and TSH were analysed. Results: Before artery embolization all thyroids were enlarged with diffusely homogenous or heterogenous low-echoes and nodules in some patients accompanied by widening of the thyroid arteries and their branches full of blood supply. The volume of thyroids decreased after artery embolization. 1-3 months later the echo of thyroids enhanced and got coarse with decrease of the thyroid vasculature and narrowing of vessel calibers except a few star- or stop-like blood streams were sometimes seen within the thyroids and no blood flow signals found in some cases. 3-6 months after embolization, the echo of thyroids decreased gradually or unevenly distributed. All the parameters of blood flow before and after the treatment showed statistically significant differences (P < 0.05). Conclusions: Embolization of thyroid arteries is a relatively new and effective technique in treating hyperthyroidism. Colour Doppler ultrasonography plays an important role for correct diagnosis and prognostication

  8. Peritoneal inclusion cysts: Changes on follow-up ultrasonography

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Lee, Jin Hee; Lee, Hee Jung; Lee, Sung Moon; Woo, Seong Ku

    2003-01-01

    To evaluate the volume change of peritoneal inclusion cysts on the follow-up ultrasonography (US). From March 1995 to May 1999, thirty seven women with ultrasonographically diagnosed peritoneal inclusion cysts were included in this study. Six patients underwent surgery for several reasons. Follow-up ultrasonography was performed 70-456 days (mean=191 days) after initial US examination in 12 of the remaining 31 patient with no further treatment. US was performed with a 3.5 or 4 MHz transabdominal probe in all 18 patients who underwent either surgery or follow-up US, and additional tranvaginal US examination using a 5-7 MHz probe in 15 of 18 patients. The volume change of the cysts was recorded for each US examination. Three cysts (25%) (volume=170 cm 3 , 61 cm 3 , and 38 cm 3 , respectively) were completely resolved on the follow-up US while the other nine cysts showed a decreased volume in seven patients (58%) and increased volume in two patients (17%). Spontaneous regression of peritoneal inclusion cysts is more common than it is believed to be, and ultrasonography may be a useful follow-up examination for peritoneal inclusion cysts.

  9. Defining normal liver stiffness range in a normal healthy Chinese population without liver disease.

    Directory of Open Access Journals (Sweden)

    James Fung

    Full Text Available BACKGROUND: For patients with chronic liver disease, different optimal liver stiffness cut-off values correspond to different stages of fibrosis, which are specific for the underlying liver disease and population. AIMS: To establish the normal ranges of liver stiffness in the healthy Chinese population without underlying liver disease. METHODS: This is a prospective cross sectional study of 2,528 healthy volunteers recruited from the general population and the Red Cross Transfusion Center in Hong Kong. All participants underwent a comprehensive questionnaire survey, measurement of weight, height, and blood pressure. Fasting liver function tests, glucose and cholesterol was performed. Abdominal ultrasound and transient elastography were performed on all participants. RESULTS: Of the 2,528 subjects, 1,998 were excluded with either abnormal liver parenchyma on ultrasound, chronic medical condition, abnormal blood tests including liver enzymes, fasting glucose, fasting cholesterol, high body mass index, high blood pressure, or invalid liver stiffness scan. The reference range for the 530 subjects without known liver disease was 2.3 to 5.9 kPa (mean 4.1, SD 0.89. The median liver stiffness was higher in males compared with females (4.3 vs 4.0 kPa respectively, p55 years (p=0.001. CONCLUSIONS: The healthy reference range for liver stiffness in the Chinese population is 2.3 to 5.9 kPa. Female gender and older age group was associated with a lower median liver stiffness.

  10. Unilateral Hemithorax Opacification on Chest Radiograph : Comparison of Diagnostic Accuracy of Chest Ultrasonography with CT

    Energy Technology Data Exchange (ETDEWEB)

    Namkung, Sook; Lee, Kyung Soo; Kwon, O Jung [Samsung Medical Center, Seoul (Korea, Republic of); Chung, Seung Eun [Sangkye Paek Hospital, Seoul (Korea, Republic of)

    1996-12-15

    To compare the diagnostic accuracy of chest ultrasonography (US) with computed tomography (CT) inpatients with opacification more than one third of unilateral hemithorax on chest radiograph (CXR). Chest US and CT scans from 41 consecutive patients with opacification more than one third of unilateral hemithorax on CXR were prospectively evaluated by two independent radiologists. Each radiologist recorded 1) the nature of pleural effusion (transudate vs. exudate), 2) presence or absence of pulmonary lesion, 3) the characteristic of pulmonary lesion (consolidation or atelectasis and tumor), and 4) presence of solid pleural tumor. The diagnostic accuracy of chest US was compared with CT scan in patients with pleural, pulmonary or other disease. In 32 patients with pleural effusion, differentiation between transudate and exudate was feasible in 27 (84%) patients with US and 26 (81%) patients with CT. In 32 patients with pulmonary and other pleural diseases, sensitivity, specificity and accuracy of US in lesion detection were 86%, 75% and 83% respectively when CT was regarded as a diagnostic gold standard. The diagnostic accuracy of chest US is comparable to CT in patients with hemithorax opacification on CXR

  11. Unilateral Hemithorax Opacification on Chest Radiograph : Comparison of Diagnostic Accuracy of Chest Ultrasonography with CT

    International Nuclear Information System (INIS)

    Namkung, Sook; Lee, Kyung Soo; Kwon, O Jung; Chung, Seung Eun

    1996-01-01

    To compare the diagnostic accuracy of chest ultrasonography (US) with computed tomography (CT) inpatients with opacification more than one third of unilateral hemithorax on chest radiograph (CXR). Chest US and CT scans from 41 consecutive patients with opacification more than one third of unilateral hemithorax on CXR were prospectively evaluated by two independent radiologists. Each radiologist recorded 1) the nature of pleural effusion (transudate vs. exudate), 2) presence or absence of pulmonary lesion, 3) the characteristic of pulmonary lesion (consolidation or atelectasis and tumor), and 4) presence of solid pleural tumor. The diagnostic accuracy of chest US was compared with CT scan in patients with pleural, pulmonary or other disease. In 32 patients with pleural effusion, differentiation between transudate and exudate was feasible in 27 (84%) patients with US and 26 (81%) patients with CT. In 32 patients with pulmonary and other pleural diseases, sensitivity, specificity and accuracy of US in lesion detection were 86%, 75% and 83% respectively when CT was regarded as a diagnostic gold standard. The diagnostic accuracy of chest US is comparable to CT in patients with hemithorax opacification on CXR

  12. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    Science.gov (United States)

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of

  13. Development and clinical application of transient elastography(FibroScan

    Directory of Open Access Journals (Sweden)

    Guo-feng CHEN

    2011-11-01

    Full Text Available Chronic liver fibrosis,an important step in the development of liver diseases,is an anaplerotic reaction of an organism to chronic liver damage caused by various kinds of pathogens.It is a common pathologic change in chronic liver diseases and the intermediate link in the development of liver cirrhosis.Liver fibrosis can be reversed in the early stage,as well as in the later stage.Cases of liver cirrhosis that are confirmed during the earlier stage can be treated and prognosticated more efficiently.Currently,liver biopsy is still the gold standard for diagnosing liver fibrosis.However,its invasiveness causes patients to refuse the examination.Noninvasive diagnostic technology for liver fibrosis has made considerable development in recent years.One of these technologies is transient elastography(FibroScan of liver stiffness using elastic shear wave,which has good accuracy and specificity for the determination of liver fibrosis.It is noninvasive,fast,repeatable,and it can evaluate liver fibrosis objectively and quantitatively.It will have a broad range of clinical applications in the future.

  14. Liver enlargement demonstrated by scintigraphy in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Tiger, L.H.; Gordon, M.H.; Ehrlich, G.E.; Shapiro, B.

    1976-03-01

    Scintigraphic scanning employing technetium-99m sulfur colloid was used to assess the size of the liver and spleen in 32 consecutive patients with rheumatoid arthritis. The data were correlated with clinical and laboratory assessment. Seven patients had enlarged livers, three enlarged spleens. An expected correlation of liver enlargement with Sjogren's syndrome did not materialize. Splenic enlargement and liver enlargement were discordant. Liver enlargement correlation best with elevations of rheumatoid factor as measured by latex fixation. As liver enlargement is not an appreciated feature of rheumatoid arthritis, these findings suggest that hepatomegaly need not necessarily imply adverse treatment results or the development of lymphoproliferative disorders.

  15. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    Science.gov (United States)

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  16. Evaluation of abdominal fat index by ultrasonography and its relationship with psoriasis and metabolic syndrome.

    Science.gov (United States)

    Gönül, Müzeyyen; Tatar, İdil; Canpolat, Filiz; Işıl Kurmus, Gökçe; Ergin, Can; Hekimoğlu, Baki

    2017-10-01

    Accumulating evidence indicates that psoriasis is associated with obesity and metabolic syndrome. Psoriasis and obesity share similar inflammatory mediators, and obesity may potentiate some inflammatory cytokines seen in psoriasis. Body fat distribution, particularly visceral adipose tissue (VAT), is an important factor in metabolic syndrome and atherosclerotic diseases. An association has been demonstrated between psoriasis and abdominal VAT measured by computed tomography (CT). To measure abdominal VAT noninvasively by ultrasonography (USG) in patients with psoriasis and investigated its relation to psoriasis and metabolic syndrome. The study population consisted of 41 psoriasis patients and 41 control subjects matched for age, sex, and body mass index. The maximal preperitoneal fat thickness (Pmax) at the anterior surface of the liver and the minimal subcutaneous fat thickness (Smin) of the abdomen were measured by USG. The abdominal fat index (AFI = Pmax/Smin ratio) was calculated and the results were compared between groups. The rate of metabolic syndrome was significantly higher in psoriasis patients ( p = 0.0018). The mean AFI was similar in both groups. AFI was not associated with psoriasis in subjects with metabolic syndrome ( p = 0.495) or with Psoriasis Area and Severity Index ( r = 0.123, p = 0.443). This is the first study to evaluate abdominal VAT by USG. Computed tomography may be more reliable than USG, but its high cost and radiation exposure are major disadvantages. Further studies are required to determine the relationships between psoriasis and VAT.

  17. Unenhanced and Contrast-Enhanced Ultrasonography During Hepatic Transarterial Embolization and Chemoembolization With Drug-Eluting Beads

    International Nuclear Information System (INIS)

    Moschouris, Hippocrates; Malagari, Katerina; Kornezos, Ioannis; Papadaki, Marina Georgiou; Gkoutzios, Panagiotis; Matsaidonis, Dimitrios

    2010-01-01

    The purpose of this study was to describe and evaluate the findings of unenhanced ultrasonography (US) and contrast-enhanced ultrasonography (CEUS) when these modalities are applied during transarterial embolization (TAE) or transarterial chemoembolization (TACE) of liver tumors. Sixteen tumors (9 hepatocellular carcinomas, 5 metastases from colorectal cancer, and 2 hemangiomas) were treated with TAE with microspheres and/or TACE with drug-eluting beads. All of these lesions were studied with intraprocedural unenhanced US and 12 were studied with intraprocedural CEUS. For the latter, a second-generation echo-enhancer (SonoVue; Bracco, Milan, Italy) and a low mechanical index technique were used. Intraprocedural findings were classified according to an arbitrary scale and were compared with pretreatment imaging (CEUS and computed tomography or CEUS and magnetic resonance imaging), with postembolization angiography, and with follow-up results. On unenhanced intraprocedural US, 13 of 16 tumors demonstrated intralesional high-level echoes of varying extent. These feature correlated poorly (r = 0.33, p = 0.097) with and generally underestimated the actual extent of necrosis. Exceptionally, high-level echoes that occupied the largest part of the treated lesions were associated with >50% tumor necrosis. Intraprocedural CEUS clearly depicted immediate partial or complete disappearance of tumor enhancement as a result of TAE/TACE. Three of 6 tumors with complete devascularization on postembolization angiogram showed residual enhancement on intraprocedural CEUS. Intraprocedural CEUS findings correlated closely (r = 0.91, p = 0.002) with follow-up findings. Intraprocedural sonography, particularly with echo-enhancers, could be used for intraprocedural monitoring in selected cases of liver tumors that undergo TAE or TACE.

  18. Prenatal diagnosis of Beckwith-Wiedemann syndrome by two- and three-dimensional ultrasonography

    Directory of Open Access Journals (Sweden)

    Edward Araujo Junior

    2013-12-01

    Full Text Available Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.

  19. Evaluation of abdominal palpation, radiography and ultrasonography for pregenancy diagnosis in bitches

    International Nuclear Information System (INIS)

    Arunmozhi, N.; Naidu, K.V.; Sreenu, M.; Rao, A.S.

    2005-01-01

    Abdominal palpation, radiography and ultrasonography were compared for pregnancy diagnosis in bitches. The earliest correct diagnosis of pregnancy was made by 22 and 21 days with abdominal palpation and ultrasonography respectively, while radiography led to more accurate diagnosis in last trimester of pregnancy. All the methods revealed 100 per cent accuracy in last trimester where as ultrasonography gave constant results from day 21 up to termination of pregnancy followed by abdominal palpation

  20. Amoebic liver

    African Journals Online (AJOL)

    lymphadenopathy were noted. The right-sided pleural effusion with relaxation atelectasis was also con- firmed (Fig. 4). The diagnosis of pos- sible amoebic liver abscess complicat- ed by rupture to the gallbladder was made at that stage. Ultrasound-guided abscess drainage was done and approximately 300 ml of pus was.

  1. Hepatic (Liver) Function Panel

    Science.gov (United States)

    ... Educators Search English Español Blood Test: Hepatic (Liver) Function Panel KidsHealth / For Parents / Blood Test: Hepatic (Liver) ... kidneys ) is working. What Is a Hepatic (Liver) Function Panel? A liver function panel is a blood ...

  2. American Liver Foundation

    Science.gov (United States)

    ... Cirrhosis Clinical Trials Galactosemia Gilbert Syndrome Hemochromatosis Hepatic Encephalopathy Hepatitis A Hepatitis B Hepatitis C Hepatocellular Carcinoma Lysosomal Acid Lipase Deficiency(LALD) Intrahepatic Cholestasis of Pregnancy (ICP) Liver Biopsy Liver Cancer Liver Cysts Liver Function Tests ...

  3. Elevated Liver Enzymes

    Science.gov (United States)

    Symptoms Elevated liver enzymes By Mayo Clinic Staff Elevated liver enzymes may indicate inflammation or damage to cells in the liver. Inflamed or ... than normal amounts of certain chemicals, including liver enzymes, into the bloodstream, which can result in elevated ...

  4. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Lee, Myoung Seok; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup; Park, Joong Shin; Jun, Jong Kwan

    2017-01-01

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP

  5. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok [Dept. of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Joong Shin; Jun, Jong Kwan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP.

  6. Intraoperative Ultrasonography during Drainage for Chronic Subdural Hematomas: A Technique to Release Isolated Deep-seated Hematomas—Technical Note

    Science.gov (United States)

    SHIMIZU, Satoru; MOCHIZUKI, Takahiro; OSAWA, Shigeyuki; KUMABE, Toshihiro

    2015-01-01

    After the drainage of chronic subdural hematomas (CSDHs), residual isolated deep-seated hematomas (IDHs) may recur. We introduce intraoperative ultrasonography to detect and remove such IDHs. Intra-operative ultrasonography is performed with fine transducers introduced via burr holes. Images obtained before dural opening show the CSDHs, hyper- and/or hypoechoic content, and mono- or multilayers. Images are also acquired after irrigation of the hematoma under the dura. Floating hyperechoic spots (cavitations) on the brain cortex created by irrigation confirm the release of all hematoma layers; areas without spots represent IDHs. Their overlying thin membranes are fenestrated with a dural hook for irrigation. Ultrasonographs were evaluated in 43 CSDHs (37 patients); 9 (21%) required IDH fenestration. On computed tomography scans, 17 were homogeneous-, 6 were laminar-, 16 were separated-, and 4 were trabecular type lesions. Of these, 2 (11.8%), 3 (50%), 4 (25%), and 0, respectively, manifested IDHs requiring fenestration. There were no technique-related complications. Patients subjected to IDH fenestration had lower recurrence rates (11.1% vs. 50%, p = 0.095) and required significantly less time for brain re-expansion (mean 3.78 ± 1.62 vs. 18 ± 5.54 weeks, p = 0.0009) than did 6 patients whose IDHs remained after 48 conventional irrigation and drainage procedures. Intraoperative ultrasonography in patients with CSDHs facilitates the safe release of hidden IDHs. It can be expected to reduce the risk of postoperative hematoma recurrence and to shorten the brain re-expansion time. PMID:26345671

  7. Comparison of the results of abdominal ultrasonography and exploratory laparotomy in the dog and cat.

    Science.gov (United States)

    Pastore, Gina E; Lamb, Christopher R; Lipscomb, Victoria

    2007-01-01

    Results of preoperative ultrasonography and exploratory laparotomy were reviewed retrospectively in a series of 100 small animals to assess the agreement between ultrasonographic and surgical findings and to identify abdominal lesions likely to be missed by ultrasonography. Good agreement occurred between ultrasound reports and surgical reports in 64% of the animals, which supported the use of ultrasonography in potential surgical candidates. A major discrepancy was observed between the ultrasound report and surgical findings in 25% of the animals. Of the various types of pathology encountered in the study, gastrointestinal ulceration or perforation was the most likely lesion to be missed by ultrasonography.

  8. Low density in liver of idiopathic portal hypertension

    International Nuclear Information System (INIS)

    Ishito, Hiroyuki

    1988-01-01

    In order to evaluate the diagnostic value of low density in liver on computed tomography (CT), CT scans of 11 patients with idiopathic portal hypertension (IPH) were compared with those from 22 cirrhotic patients, two patients with scarred liver and 16 normal subjects. Low densities on plain CT scans in patients with IPH were distinctly different from those observed in normal liver. Some of the low densities had irregular shape with unclear margin and were scattered near the liver surface, and others had vessel-like structures with unclear margin and extended as far as near the liver surface. Ten of the 11 patients with IPH had low densities mentioned above, while none of the 22 cirrhotic patients had such low densities. The present results suggest that the presence of low densities in liver on plain CT scan is clinically beneficial in diagnosis of IPH. (author)

  9. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  10. CT appearance of focal fatty infiltration of the liver

    International Nuclear Information System (INIS)

    Halvorsen, R.A.; Korobkin, M.; Ram, P.C.; Thompson, W.M.

    1982-01-01

    Focal fatty infiltration of the liver is an entity that may be confused with liver metastasis on computed tomography (CT). The imaging results and medical records of 16 patients with CT appearance suggestive of focal fatty liver were reviewed, three of whom had the simultaneous presence of metastitic liver disease. Focal fatty liver often has a distinctive appearance with CT, usually with a nonspherical shape, absence of mass effect, and density close to water. Liver metastases are usually round or oval, and unless cystic or necrotic, they have CT attenuation values closer to normal liver parenchyma than water. A radionuclide liver scan almost always resolves any confusion about the differential diagnosis of focal fatty liver: a well defined focus of photon deficiency is due to neoplasm rather than focal fatty infiltration. Sonography sometimes helps to confirm the CT impression, but may be misleading if the diagnosis of focal or diffuse fatty infiltration is not suspected before the examination

  11. Preoperative Duplex Scanning is a Helpful Diagnostic Tool in Neurogenic Thoracic Outlet Syndrome.

    Science.gov (United States)

    Orlando, Megan S; Likes, Kendall C; Mirza, Serene; Cao, Yue; Cohen, Anne; Lum, Ying Wei; Freischlag, Julie A

    2016-01-01

    To evaluate the diagnostic role of venous and arterial duplex scanning in neurogenic thoracic outlet syndrome (NTOS). Retrospective review of patients who underwent duplex ultrasonography prior to first rib resection and scalenectomy (FRRS) for NTOS from 2005 to 2013. Abnormal scans included ipsilateral compression (IC) with abduction of the symptomatic extremity (>50% change in subclavian vessel flow), contralateral (asymptomatic side) compression (CC) or bilateral compression (BC). A total of 143 patients (76% female, average age 34, range 13-59) underwent bilateral preoperative duplex scanning. Ipsilateral compression was seen in 44 (31%), CC in 12 (8%), and BC in 14 (10%). Seventy-three (51%) patients demonstrated no compression. Patients with IC more often experienced intraoperative pneumothoraces (49% vs. 25%, P duplex ultrasonography can assist in NTOS diagnosis. Ipsilateral compression on abduction often correlates with Adson testing. © The Author(s) 2016.

  12. Ultrasonography survey and thyroid cancer in the Fukushima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Peter; Kaiser, Jan Christian; Ulanovsky, Alexander [Helmholtz Zentrum Muenchen-German Research Center for Environmental Health, Department of Radiation Sciences, Institute of Radiation Protection, Neuherberg (Germany)

    2014-05-15

    Thyroid cancer is one of the major health concerns after the accident in the Fukushima Dai-ichi nuclear power station (NPS). Currently, ultrasonography surveys are being performed for persons residing in the Fukushima Prefecture at the time of the accident with an age of up to 18 years. Here, the expected thyroid cancer prevalence in the Fukushima Prefecture is assessed based on an ultrasonography survey of Ukrainians, who were exposed at an age of up to 18 years to {sup 131}I released during the Chernobyl NPS accident, and on differences in equipment and study protocol in the two surveys. Radiation risk of thyroid cancer incidence among survivors of the atomic bombings of Hiroshima and Nagasaki and preliminary estimates of thyroid dose due to the Fukushima accident were used for the prediction of baseline and radiation-related thyroid cancer risks. We estimate a prevalence of thyroid cancer of 0.027 % (95 % CI 0.010 %; 0.050 %) for the first screening campaign in the Fukushima Prefecture. Compared with the incidence rate in Japan in 2007, the ultrasonography survey is predicted to increase baseline thyroid cancer incidence by a factor of 7.4 (95 % CI 0.95; 17.3). Under the condition of continued screening, thyroid cancer during the first fifty years after the accident is predicted to be detected for about 2 % of the screened population. The prediction of radiation-related thyroid cancer in the most exposed fraction (a few ten thousand persons) of the screened population of the Fukushima Prefecture has a large uncertainty with the best estimates of the average risk of 0.1-0.3 %, depending on average dose. (orig.)

  13. Stomach: ultrasonography evaluation and post mortem inspection in adult horses

    Directory of Open Access Journals (Sweden)

    Cristiano Chaves Pessoa da Veiga

    2014-06-01

    Full Text Available ABSTRACT. Veiga C.C.P., Cascon C.M., Souza B.G., Braga L.S.M., Souza V.C., Ferreira A.M.R. & Leite J.S. [Stomach: ultrasonography evaluation and post mortem inspection in adult horses.] Avaliação ultrassonográfica e anatomopatológica macroscópica do estômago de equinos destinados ao abate comercial. Revista Brasileira de Medicina Veterinária, 36(2:125-130, 2014. Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR 465, km 7, Seropédica, 23890-000, RJ, Brasil. E-mail: radiovet@ufrrj.br The equine gastric ulcer syndrome (EGUS includes all symptomatic or asymptomatic cases of erosions, ulcers, gastritis, gastric emptying disorders, duodenitis, duodenal ulcers and complications of these disorders. Occupies a prominent place in the equine clinic where you can go for the death of the animal. Ultrasonography of the stomach is indicated when the animals showed clinical signs of gastric disease. The aim of this study was to describe the sonographic evaluation and macroscopic pathological findings of the stomach of adult horses intended for commercial slaughter. To this 39 intended for commercial slaughter horses were evaluated. Sonographic evaluation before slaughter transabdominal via the left side of abdomen for evaluation of the stomach was performed. After the slaughter of these animals their stomachs were collected, evaluated and photographed. The study concluded that ultrasonography identified the stomach in all animals evaluated, but did not allow a careful evaluation of the entire length of the viscera, especially the aglandular region and pleated border. All animals evaluated had injury to the gastric mucosa in different degrees. In animals evaluated, the stomach region was most affected by injuries glandular region, although the most severe lesions have been found in the ruffled border adjacent to aglandular region.

  14. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  15. Carcinoembryonic Antigen Level in Liver Disease

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kyoo Ok; Kim, Ki Whang; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1978-09-15

    Carcinoembryonic antigen was initially known as tumor specific antigen and had a potential diagnostic value in the detection of digestive tract malignancies. However, subsequent studies showed CEA and CEA-like antigen present in benign disease, particularly in liver. We had collected sera from 58 patients who had liver scan and later were diagnosed clinically and histologically as liver disease. We estimated CEA values and correlations were made with liver function tests in liver cirrhosis cases. The results: 1) The raised plasma carcinoembryonic antigen level were found in 13 (68.4%) of 19 patients cirrhosis, 5 (27.8%) of 18 patients in hepatoma, 5 (71%) of 7 patients in chronic active hepatitis, all 3 patients in liver abscesses, 2 (66.7%) of 3 patients in liver abscesses, 2 (66.7%) of 3 patients in obstructive biliary disease and none in each one patient of traumatic liver hematoma, subphrenic abscess and clonorchiasis. 2) There is no linear correlation between carcinoembryonic antigen level and liver function tests including serum bilirubin, alkaline phosphatase, SGOT and prothrombin time in liver patients.

  16. Carcinoembryonic Antigen Level in Liver Disease

    International Nuclear Information System (INIS)

    Choi, Kyoo Ok; Kim, Ki Whang; Park, Chang Yun

    1978-01-01

    Carcinoembryonic antigen was initially known as tumor specific antigen and had a potential diagnostic value in the detection of digestive tract malignancies. However, subsequent studies showed CEA and CEA-like antigen present in benign disease, particularly in liver. We had collected sera from 58 patients who had liver scan and later were diagnosed clinically and histologically as liver disease. We estimated CEA values and correlations were made with liver function tests in liver cirrhosis cases. The results: 1) The raised plasma carcinoembryonic antigen level were found in 13 (68.4%) of 19 patients cirrhosis, 5 (27.8%) of 18 patients in hepatoma, 5 (71%) of 7 patients in chronic active hepatitis, all 3 patients in liver abscesses, 2 (66.7%) of 3 patients in liver abscesses, 2 (66.7%) of 3 patients in obstructive biliary disease and none in each one patient of traumatic liver hematoma, subphrenic abscess and clonorchiasis. 2) There is no linear correlation between carcinoembryonic antigen level and liver function tests including serum bilirubin, alkaline phosphatase, SGOT and prothrombin time in liver patients.

  17. Diagnostic accuracy of the ultrasonography in complicated pregnancy

    International Nuclear Information System (INIS)

    Cha, Kyung Soo; Kim, Kun Sang; Park, Soo Soung

    1983-01-01

    Ultrasonography is an invaluable diagnostic method in Obstetrics. It provides safe, speedy and repeatable way to obtain image of normal and abnormal pregnancy. The ultrasonograms of 167 patients with suspicion of complicated pregnancy were analyzed. The results were as follows. 1. 86 patients showed normal ultrasonogram(50.9%). 100% in intrauterine fetal death and gross fetal anomaly, 100% in abnormal fetal position and number, 95% in pregnancy with pelvic mass, 83% in ectopic pregnancy, 81% in abortion, 78% in molar pregnancy, 74% in plancenta previa. 3. Ultrasonic diagnosis of abrupto placenta was difficult. 4. Diagnostic accuracy was 80% in bicornuate uterus and double vagina

  18. Clinical application of endoscopic ultrasonography for esophageal achalasia.

    Science.gov (United States)

    Minami, Hitomi; Inoue, Haruhiro; Isomoto, Hajime; Urabe, Shigetoshi; Nakao, Kazuhiko

    2015-04-01

    Endoscopic ultrasonography (EUS) has been widely used for evaluating the nature of diseases of various organs. The possibility of applying EUS for esophageal motility diseases has not been well discussed despite its versatility. At present, peroral endoscopic myotomy (POEM) for esophageal achalasia and related diseases has brought new attention to esophageal diseases because POEM provides a more direct approach to the inner structures of the esophageal wall. In the present study, we discuss the clinical utility of EUS in evaluating and treating esophageal motility diseases such as esophageal achalasia and related diseases. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  19. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  20. A pilot trial of body weight reduction for nonalcoholic fatty liver disease with a home-based lifestyle modification intervention delivered in collaboration with interdisciplinary medical staff

    International Nuclear Information System (INIS)

    Oza, Noriko; Eguchi, Yuichiro; Mizuta, Toshihiko

    2009-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a hepatic manifestation of the metabolic syndrome. The aim of this study was to evaluate a 6-month home-based lifestyle modification intervention delivered in collaboration with physicians, hygienists, registered dietitians, and nurses. Outpatients with NAFLD diagnosed by abdominal ultrasonography were eligible for this study. Abdominal computed tomography (CT) scan evaluated liver fat deposition by the liver-spleen ratio (L/S ratio) and visceral fat accumulation as the visceral fat area (VFA; cm 2 ). During the 6-month home-based lifestyle modification intervention, each patient was examined by physicians, nurses, hygienists, and registered dietitians, who provided individualized advice to the patients. Patients recorded their daily weight for self-control of weight with recommended diet and exercise regimens. Sixty-seven NAFLD patients were enrolled in this study and 22 patients (32.8%) completed the 6-month intervention. Nineteen of the 22 patients achieved significant improvements in body weight, body mass index (BMI), waist circumference, VFA, L/S ratio, and systolic blood pressure, with improved laboratory data. Overall, 39 patients withdrew from the intervention. The mean age of the patients who withdrew was 50.0±11.0 years, which was significantly younger than that of the patients who were followed up (60.1±10.1 years; P<0.01). The reduction in body weight achieved by NAFLD patients during the 6-month intervention was associated with improved fat deposition and liver function. This intervention offers a practical approach for treating a large number of NAFLD patients with lifestyle modification therapy. (author)

  1. NGA/Insulin receptor scanning

    International Nuclear Information System (INIS)

    Kurtaran, A.; Virgolini, I.

    1994-01-01

    Tc-99m-galactosyl-neoglycoalbumin (NGA) is one of the first receptor-based radiopharmaceuticals which specifically recognizes the hepatic binding protein (HBP) located on the surface of the hepatocytes. The exclusive interactin of NGA with HBP provided the basis for a kinetic model for the evaluation hepatocellular function. During the last years we have used NGA in more than 300 patients with various liver diseases including liver cirrhosis (Stages Child A to Child C), viral hepatitis, and carcinomas. In these studies, the calculated HBP densities, after i.v.-injection of Tc-99m-NGA, significantly correlated with the clinical course of the diseases. Furthermore, similar to conventional Tc-colloid, NGA provided excellent demonstration of 'cold spots' for hepatic masses. In a further approach we used another hepatocyte receptor-seeking radioligand, I-123-Tyr-A14- insulin, and found, that its in vitro-binding to hepatocellular carcinomas is greatly enhanced over normal hepatic tissue. On this basis, we developed a double-tracer method using NGA and insulin in a single study. Thus, areas of 'cold spots' identifying hepatic masses on NGA scans, take up I-123-Tyr-A14-insulin immediately after i.v.-injection. This was true for hepatocellular hepatomas, but not for adenocarcinomas. In conclusion, NGA/insulin receptor scanning could be a novel and save method for the demonstration of hepatocellular hepatomas. (author)

  2. NGA/Insulin receptor scanning

    Energy Technology Data Exchange (ETDEWEB)

    Kurtaran, A; Virgolini, I [Vienna Univ. (Austria). Abt. fuer Nuklearmedizin; Angelberger, P [Ludwig Boltzmann-Institut fuer Nuklearmedizin, Vienna (Austria)

    1994-10-01

    Tc-99m-galactosyl-neoglycoalbumin (NGA) is one of the first receptor-based radiopharmaceuticals which specifically recognizes the hepatic binding protein (HBP) located on the surface of the hepatocytes. The exclusive interactin of NGA with HBP provided the basis for a kinetic model for the evaluation hepatocellular function. During the last years we have used NGA in more than 300 patients with various liver diseases including liver cirrhosis (Stages Child A to Child C), viral hepatitis, and carcinomas. In these studies, the calculated HBP densities, after i.v.-injection of Tc-99m-NGA, significantly correlated with the clinical course of the diseases. Furthermore, similar to conventional Tc-colloid, NGA provided excellent demonstration of `cold spots` for hepatic masses. In a further approach we used another hepatocyte receptor-seeking radioligand, I-123-Tyr-A14- insulin, and found, that its in vitro-binding to hepatocellular carcinomas is greatly enhanced over normal hepatic tissue. On this basis, we developed a double-tracer method using NGA and insulin in a single study. Thus, areas of `cold spots` identifying hepatic masses on NGA scans, take up I-123-Tyr-A14-insulin immediately after i.v.-injection. This was true for hepatocellular hepatomas, but not for adenocarcinomas. In conclusion, NGA/insulin receptor scanning could be a novel and save method for the demonstration of hepatocellular hepatomas. (author).

  3. The diagnostic application of radiocolloid liver scintigraphy in breast carcinoma

    International Nuclear Information System (INIS)

    Galli, G.; Maini, C.L.; Salvatori, M.; Cefaro, G.A.

    1982-01-01

    The authors have reviewed their experiences in determining the presence of liver metastases in 103 patients by radiocolloid scanning. The sensitivity of liver scanning proved to be quite low if the presence of focal defects in the distribution of the tracer was chosen as the diagnostic criterion. The inclusion of less restrictive criteria such as liver enlargement or irregular distribution of the tracer, resulted in a higher sensitivity without lowering the predictive value of a negative scan. Using the latter diagnostic criterion, sensitivity, specificity and accuracy were in the range of 90%. Abnormal liver scans are common in patients classified as T3-T4 or N+ and their chances of being 'true positive' are high. Conversely, abnormal scans are seldom found in patients classified as T1-T2 or N 0 and probabilities of 'false positive' results are high. (orig.) [de

  4. A novel two-dimensional dynamic anal ultrasonography technique to assess anismus comparing with three-dimensional echodefecography.

    Science.gov (United States)

    Murad-Regadas, S M; Regadas, F S P; Barreto, R G L; Rodrigues, L V; de Souza, M H L P

    2009-10-01

    The aim of this prospective study was to test two-dimensional dynamic anorectal ultrasonography (2D-DAUS) in the assessment of anismus and compare it with echodefecography (ECD). Fifty consecutive female patients with outlet delay were submitted to 2D and 3D-DAUS, measuring the relaxing or contracting puborectalis muscle angle during straining. The patients were assigned to one of two groups based on ECD findings. Group I consisted of 29 patients without anismus and group II included 21 patients diagnosed with anismus. Subsequently 2D-DAUS images were checked for anismus and compared with ECD findings. Upon straining, the angle produced by the movement of the puborectalis muscle decreased in 26 out of the 29 (89.6%) patients of group I and increased 19 out of the 21 (90.4%) patients of group II. The mean angle during straining differed significantly between group I and group II. The index of agreement between the two scanning modes was 89.6% (26/29) for group I (Kappa: 0.796; CI: 95%; range: 0.51-1.0) and 90.4% (19/21) for group II (Kappa: 0.796; CI: 95%; range: 0.51-1.0). Two-dimensional dynamic anal ultrasonography can be used as an alternative method to assess patients with anismus, although the 3-D modality is more precise to evaluate the PR angle as the sphincters integrity as the whole muscle length is clearly visualized.

  5. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  6. Quadriceps Function and Knee Joint Ultrasonography after ACL Reconstruction.

    Science.gov (United States)

    Pamukoff, Derek N; Montgomery, Melissa M; Moffit, Tyler J; Vakula, Michael N

    2018-02-01

    Individuals with anterior cruciate ligament reconstruction (ACLR) are at greater risk for knee osteoarthritis, partially because of chronic quadriceps dysfunction. Articular cartilage is commonly assessed using magnetic resonance imaging and radiography, but these methods are expensive and lack portability. Ultrasound imaging may provide a cost-effective and portable alternative for imaging the femoral cartilage. The purpose of this study was to compare ultrasonography of the femoral cartilage between the injured and uninjured limbs of individuals with unilateral ACLR, and to examine the association between quadriceps function and ultrasonographic measures of femoral cartilage. Bilateral femoral cartilage thickness and quadriceps function were assessed in 44 individuals with unilateral ACLR. Quadriceps function was assessed using peak isometric strength, and early (RTD100) and late (RTD200) rate of torque development. Cartilage thickness at the medial femoral condyle (P accounting for time since ACLR, quadriceps peak isometric strength was associated with cartilage thickness at the medial femoral condyle (r = 0.35, P = 0.02) and femoral cartilage cross-sectional area (r = 0.28, P = 0.04). RTD100 and RTD200 were not associated with femoral cartilage thickness or cross-sectional area. Individuals with ACLR have thinner cartilage in their injured limb compared with uninjured limb, and cartilage thickness is associated with quadriceps function. These results indicate that ultrasonography may be useful for monitoring cartilage health and osteoarthritis progression after ACLR.

  7. Three-dimensional ultrasonography in the diagnosis of deep endometriosis.

    Science.gov (United States)

    Guerriero, Stefano; Saba, Luca; Ajossa, Silvia; Peddes, Cristina; Angiolucci, Marco; Perniciano, Maura; Melis, Gian Benedetto; Alcázar, Juan Luis

    2014-06-01

    In the use of 'tenderness-guided' transvaginal ultrasound, is the diagnostic accuracy of three-dimensional (3D) ultrasonography better than two-dimensional (2D) ultrasonography in the identification of deep endometriosis? Three-dimensional ultrasonography has a significantly higher diagnostic accuracy in the diagnosis of posterior locations of deep endometriosis without intestinal involvement, such as the uterosacral ligaments, vaginal and rectovaginal endometriosis. The only previous study of the diagnosis of posterior compartment endometriosis reported an poor sensitivity of 3D ultrasonography for uterosacral and sigmoid colon involvement. This diagnostic test study included 202 patients scheduled for surgery because of clinical suspicion of deep pelvic endometriosis and was carried out between January 2009 and September 2012. Modified transvaginal ultrasonography was performed on all of the women by a single examiner. Two locations of deep endometriosis were considered: intestinal involvement and other posterior lesions (including vaginal location, rectovaginal septum and uterosacral ligaments). Once the 2D ultrasonography had been performed, the 3D acquisition was performed and the obtained volume was stored. To avoid the risk of recall bias, the same operator evaluated the 3D volumes 6 months after the last examination using virtual navigation to provide a presumptive diagnosis of the presence and localization of deep endometriosis. In addition, to evaluate the reproducibility of 3D, two operators with different levels of expertise performed a retrospective review of 3D volumes from a random sample of 35 patients, twice, 1 week apart to also assess intraobserver agreement. The diagnostic performance of both tests was expressed as area under the receiver-operating characteristics curve (AUC), sensitivity, specificity, positive and negative predictive values, positive (LR+) and negative (LR-) likelihood ratios, with their respective 95% confidence interval (CI

  8. Validation of equations for pleural effusion volume estimation by ultrasonography.

    Science.gov (United States)

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  9. Usefulness of screening ultrasonography for hepatocellular carcinoma detection: chronic hepatitis versus hepatic cirrhosis caused by hepatitis B virus

    International Nuclear Information System (INIS)

    Chang, Sam Uel; Choi, Don Gil; Lim, Jae Hoon

    2004-01-01

    To evaluate the usefulness of screening liver ultrasonography (US) for hepatocellular carcinoma (HCC) detection in patients with chronic hepatitis or hepatic cirrhosis caused by hepatitis B virus (HBV). A retrospective study was performed with 1,189 patients with clinical hepatopathy caused by HBV who underwent screening liver US for HCC detection at least twice. All patients were followed up with liver US examinations (mean, 8.3 times), CT, or MR for at least 3 months (range, 3-102 months; mean, 47 months) for the detection of HCC. The study population was divided into two groups: chronic hepatitis (n=492) and hepatic cirrhosis (n=697), which was further divided into two groups with (n=156) or without (n=541) evident shrinkage. The radiologic examinations that had detected HCC for the first time were analyzed and compared between the groups. Among 20 (4.1%) patients with chronic hepatitis and 132 (18.9%) patients with hepatic cirrhosis diagnosed as HCC, screening US was the modality of detection in 17 (85.0%) of 20 patients with chronic hepatitis and 76 (57.6%) of 132 patients with hepatic cirrhosis (p=0.038, Chi-square test). The detection rate of HCC on screening US between the chronic hepatitis and hepatic cirrhosis with evident shrinkage (51.4%, 19/37) showed a significant difference (p=0.027, Chi-square test). For chronic liver disease caused by HBV, screening US for HCC detection is more useful in patients with chronic hepatitis than with hepatic cirrhosis with evident shrinkage

  10. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    Science.gov (United States)

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  11. Ultrasonography and computed tomography in the study of orbital tumors and pseudo-tumoral lesions

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Pereira, R.M.; Prando, A.; Selos Moreira, A.R. de

    1987-01-01

    The computerized tomography and the ultrasonography in the ocular and orbital patologies were considered as complementary each other. the ultrasonography method as choice for the detection of the eye lesions in the adult, particularly of vascular origin and in the follow-up of inflammatory and pseudo-tumoral lesions was chosen. (L.M.J.) [pt

  12. The detection of prostatic carcinoma. 4- or 7-MHz transrectal ultrasonography?

    NARCIS (Netherlands)

    Vleeming, R.; Noordzij, J. W.; de Reijke, T. M.; Kurth, K. H.

    1993-01-01

    In this prospective study a comparison of 4-versus 7-MHz transrectal ultrasonography for the detection of prostatic carcinoma is reported. A total of 150 prostates were biopsied due to suspicion of malignancy arising at either digital rectal examination, 4- and/or 7-MHz transrectal ultrasonography,

  13. [A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].

    Science.gov (United States)

    Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando

    2017-11-01

    Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.

  14. 肝癌双源CT双能量虚拟平扫与常规平扫的影像比较研究%Dual-source CT double energy virtual non-contrast scan in comparison with conventional non-contrast scan in diagnosis of liver cancer

    Institute of Scientific and Technical Information of China (English)

    莫家强; 刘彪; 黎军强

    2016-01-01

    目的:探讨双源CT双能量虚拟平扫(VNC)在肝癌CT诊断中的应用价值。方法对30例临床拟诊肝癌的患者,先行常规平扫(CNC)后,再行双源双能量动脉期、常规门脉期、实质期扫描。应用后处理软件 Liver VNC 得出 VNC图像,将CNC图像作为对照,分析两组在辐射剂量、图像CT值、图像信噪比等方面差异有无统计学意义。结果 VNC图像的颗粒感相对较粗,但能满足诊断要求,其图像质量评分无2分和1分图像,与CNC组比较,差异无统计学意义(P=1.000);VNC组图像的平均信噪比为(3.23±0.751),CNC组为(3.58±1.02),组间差异无统计学意义(P >0.05);而在辐射剂量方面CNC组的容积CT剂量指数(CTDIvol)为(8.62±1.95)mGy,VNC组为(4.64±1.51)mGy,组间比较差异有统计学意义(P0.05);in respect of radiation does,CT dose index volume (CTDIvol)of CNC group was (8.62±1.95)mGy and VNC group was (4.64±1.51)mGy,com-parison between the two groups showed statistically significant differences (P <0.001). Conclusion Dual source CT dual energy VNC can replace CNC in the CT diagnosis of liver cancer,which can significantly reduce the radiation does of patient receiving and has highly clinical application value.

  15. A prospective comparison of transvaginal ultrasonography and diagnostic hysteroscopy in the evaluation of patients with abnormal uterine bleeding: clinical implications

    NARCIS (Netherlands)

    Emanuel, M. H.; Verdel, M. J.; Wamsteker, K.; Lammes, F. B.

    1995-01-01

    We determined the diagnostic value of transvaginal ultrasonography for endometrial and intrauterine abnormalities in patients with abnormal uterine bleeding. Between June 1, 1992, and June 1, 1993, 279 consecutive patients underwent transvaginal ultrasonography. Findings were compared with the final

  16. Radionuclide evaluation of the liver in diabetes

    International Nuclear Information System (INIS)

    Abdel-Razzak, M.; El-Ashmawy, A.

    1982-01-01

    Hepatic involvement in diabetes has been previously demonstrated in experimental animals and in patients by clinical examination as well as by autopsy. The aim of the present work is to investigate the extent and type of hepatic involvement in diabetics by radionuclide scanning which is objective and not liable to the errors and difficulties inherent in the method of physical examination. The present study was performed on 40 diabetics, comprising 24 females and 16 males, aged between 17 and 80 years. Scanning was performed with 99m - Tc sulphur colloid using a rectilinear scanner and the gamma camera. The liver size was assessed from the scan pictures by the application of certain measurements and by surface area determination. The obtained results demonstrated marked discrepancy between the liver size as determined clinically and that evaluated by radionuclide scanning. By scintiscanning, the incidence of hepatic enlargement varied according to the parameter used. It amounted to 48% on the basis of the maximum vertical dimension and 37% with hepatic surface area measurement. Using the vertical dimension at halfway between the xiphoid and right lateral hepatic margin, the incidence of liver enlargement was 35%. Uneven distribution of radioactivity was seen in the right and/or left lobe in 20/40 patients. Furthermore, in 10 patients the ratio of hepatic to splenic radioactivity was below one. These changes could be explained by fatty infiltration and/or cirrhosis. Accordingly, hepatic scanning could be used to select diabetes having abnormal scan picture whether regarding liver dimensions or distribution of radioactivity and subjecting them to liver biopsy in order to define the nature of liver involvement. (Author)

  17. Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use.

    Science.gov (United States)

    Rella, Rossella; Belli, Paolo; Giuliani, Michela; Bufi, Enida; Carlino, Giorgio; Rinaldi, Pierluigi; Manfredi, Riccardo

    2018-03-16

    Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. The Development of a Flexible Measuring System for Muscle Volume Using Ultrasonography

    Science.gov (United States)

    Fukumoto, Kiyotaka; Fukuda, Osamu; Tsubai, Masayoshi; Muraki, Satoshi

    Quantification of muscle volume can be used as a means for the estimation of muscle strength. Its measuring process does not need the subject's muscular contractions so it is completely safe and particularly suited for elderly people. Therefore, we have developed a flexible measuring system for muscle volume using ultrasonography. In this system, an ultrasound probe is installed on a link mechanism which continuously scans fragmental images along the human body surface. These images are then measured and composed into a wide area cross-sectional image based on the spatial compounding method. The flexibility of the link mechanism enables the operator to measure the images under any body postures and body site. The spatial compounding method significantly reduces speckle and artifact noises from the composed cross-sectional image so that the operator can observe the individual muscles, such as Rectus femoris, Vastus intermedius, and so on, in detail. We conducted the experiments in order to examine the advantages of this system we have developed. The experimental results showed a high accuracy of the measuring position which was calculated using the link mechanism and presented the noise reduction effect based on the spatial compounding method. Finally, we confirmed high correlations between the MRI images and the ones of the developed system to verify the validity of the system.