  1. Cam-driven monochromator for QEXAFS

    Energy Technology Data Exchange (ETDEWEB)

    Caliebe, W.A. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); So, I. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); Lenhard, A. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); Siddons, D.P. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2006-11-15

    We have developed a cam-drive for quickly tuning the energy of an X-ray monochromator through an X-ray absorption edge for quick extended X-ray absorption spectroscopy (QEXAFS). The data are collected using a 4-channel, 12-bit multiplexed VME analog to digital converter and a VME angle encoder. The VME crate controller runs a real-time operating system. This system is capable of collecting 2 EXAFS-scans in 1 s with an energy stability of better than 1 eV. Additional improvements to increase the speed and the energy stability are under way.

  2. Cam-driven monochromator for QEXAFS

    Science.gov (United States)

    Caliebe, W. A.; So, I.; Lenhard, A.; Siddons, D. P.

    2006-11-01

    We have developed a cam-drive for quickly tuning the energy of an X-ray monochromator through an X-ray absorption edge for quick extended X-ray absorption spectroscopy (QEXAFS). The data are collected using a 4-channel, 12-bit multiplexed VME analog to digital converter and a VME angle encoder. The VME crate controller runs a real-time operating system. This system is capable of collecting 2 EXAFS-scans in 1 s with an energy stability of better than 1 eV. Additional improvements to increase the speed and the energy stability are under way.

  3. Cam-driven monochromator for QEXAFS

    International Nuclear Information System (INIS)

    Caliebe, W.A.; So, I.; Lenhard, A.; Siddons, D.P.

    2006-01-01

    We have developed a cam-drive for quickly tuning the energy of an X-ray monochromator through an X-ray absorption edge for quick extended X-ray absorption spectroscopy (QEXAFS). The data are collected using a 4-channel, 12-bit multiplexed VME analog to digital converter and a VME angle encoder. The VME crate controller runs a real-time operating system. This system is capable of collecting 2 EXAFS-scans in 1 s with an energy stability of better than 1 eV. Additional improvements to increase the speed and the energy stability are under way

  4. Reduction and re-oxidation of Cu/Al{sub 2}O{sub 3} catalysts investigated with quick-scanning XANES and EXAFS

    Energy Technology Data Exchange (ETDEWEB)

    Stoetzel, J; Luetzenkirchen-Hecht, D; Frahm, R [Department of Physics, University of Wuppertal, Gaussstr. 20, D-42097 Wuppertal (Germany); Kimmerle, B; Baiker, A [Department of Chemistry and Applied Biosciences, ETH Zuerich, CH-8093 Zuerich (Switzerland); Nachtegaal, M [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Beier, M J; Grunwaldt, J-D, E-mail: j.stoetzel@uni-wuppertal.d, E-mail: jdg@kt.dtu.d [Department of Chemical and Biochemical Engineering, Technical University of Denmark, Building 229, DK-2800 Kgs. Lyngby (Denmark)

    2009-11-15

    In the present study the structure of copper catalysts on alumina support were investigated in situ and time resolved during reduction and re-oxidation at different temperatures with the quick-scanning EXAFS (QEXAFS) technique. Different impregnation times (2 min and 90 min) were chosen for the preparation which resulted in different copper species that show a strong variation in the reduction/re-oxidation behaviour. These dynamic changes as well as possible intermediate phases during the gas atmospheres changes were followed with up to 20 EXAFS spectra per second at the copper K-edge covering an energy range of 450 eV. The high time resolution provided new insights into the dynamics of the catalysts e.g. revealing Cu(I) as intermediate state during re-oxidation. Latest advances in the data acquisition hardware are leading to an improved data quality of spectra collected at the SuperXAS beamline. Thus, not only accurate analysis of the catalysts via XANES but also by EXAFS was possible. This is also due to the recent upgrade to monitor the Bragg angle directly with an encoder during the experiments.

  5. Augmentation of Quick-EXAFS measurement facility at the energy scanning EXAFS beamline at INDUS-2 SRS

    Energy Technology Data Exchange (ETDEWEB)

    Poswal, A. K., E-mail: poswalashwini@gmail.com; Agrawal, Ankur; Bhattachryya, D.; Jha, S. N.; Sahoo, N. K. [Atomic and Molecular Physics Division, Bhabha Atomic Research Centre, Mumbai -400085 (India)

    2015-06-24

    In this paper implementation of Quick-EXAFS data acquisition facility at the Energy Scanning EXAFS beamline(BL-09) at INDUS-2 synchrotron source, Indore is presented. By adopting a continuous-scan mode in the Double Crystal monochromator (DCM), a high signal-to-noise ratio is maintained and the acquisition time is reduced to few seconds. The quality of spectra and repeatability is checked by measuring standards. The present mode of data acquisition would enable EXAFS measurement for in-situ studies even in fluorescence mode.

  6. Commissioning and first results of scanning type EXAFS beamline (BL-09) at INDUS-2 synchrotron source

    Energy Technology Data Exchange (ETDEWEB)

    Poswal, A. K., E-mail: poswalashwini@gmail.com; Agrawal, A., E-mail: poswalashwini@gmail.com; Yadav, A. K., E-mail: poswalashwini@gmail.com; Nayak, C., E-mail: poswalashwini@gmail.com; Basu, S., E-mail: poswalashwini@gmail.com; Bhattachryya, D.; Jha, S. N.; Sahoo, N. K. [Atomic and Molecular Physics Division, Bhabha Atomic Research Centre, Mumbai -400085 (India); Kane, S. R.; Garg, C. K. [Indus Synchrotrons Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore- 452013 (India)

    2014-04-24

    An Energy Scanning X-ray Absorption Fine Structure spectroscopy beamline has recently been installed and commissioned at BL-09 bending magnet port of INDUS-2 synchrotron source, Indore. The beamline uses an UHV compatible fixed exit double crystal monochromator (DCM) with two Si (111) crystals. Two grazing incidence cylindrical mirrors are also used in this beamline; the pre-mirror is used as a collimating mirror while the post mirror is used for vertical focusing and higher harmonic rejection. In this beamline it is possible to carry out EXAFS measurements both in transmission and fluorescence mode on various types of samples, using Ionization chamber detectors and solid state drift detector respectively. In this paper, results from first experiments of the Energy Scanning EXAFS beamline are presented.

  7. Quick EXAFS experiments using a now GDA eclipse RCP GUI with EPICS hardware control

    International Nuclear Information System (INIS)

    Woolliscroft, R.J.; Coles, C.; Gerring, M.; Pearson, M.

    2012-01-01

    The Generic Data Acquisition (GDA) framework is an open source, Java and Eclipse RCP based, data acquisition software framework for synchrotron and neutron facilities. A new implementation of the GDA on the B18 X-ray beamline at the Diamond synchrotron will be discussed. This beamline performs energy scanning Xray Absorption Spectroscopy (XAS) experiments. It includes a continuous-scan mode of the monochromator synchronized with various detectors for Quick EXAFS (QEXAFS) experiments. XAS energy scans may now be performed in 30 s, where the equivalent step scans take approximately 40 minutes. A new generic perspective for the GDA client has been developed in which graphical editors are used to write XML files which hold experimental parameters. The XML files are marshalled by the GDA server to create Java beans used by Jython scripts which run on the GDA server. Underlying this, a new generic continuous scanning mechanism for the GDA has been developed. The new Eclipse RCP UI, the new continuous scanning mechanism, new hardware development and integration between the two systems shall be covered. (authors)

  8. Laser EXAFS

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Schwenzel, R.E.; Campbell, B.E.

    1983-01-01

    Apparatus for obtaining EXAFS data of a material, comprising means for directing radiant energy from a laser onto a target in such manner as to produce X-rays at the target of a selected spectrum and intensity, suitable for obtaining the EXAFS spectrum of the material, means for directing X-rays from the target onto spectral dispersive means so located as to direct the spectrally resolved X-rays therefrom onto recording means, and means for positioning a sample of material in the optical path of the X-rays, the recording means providing a reference spectrum of X-rays not affected by the sample and absorption spectrum of X-rays modified by transmission through the sample

  9. Hard real-time quick EXAFS data acquisition with all open source software on a commodity personal computer

    International Nuclear Information System (INIS)

    So, I.; Siddons, D.P.; Caliebe, W.A.; Khalid, S.

    2007-01-01

    We describe here the data acquisition subsystem of the Quick EXAFS (QEXAFS) experiment at the National Synchrotron Light Source of Brookhaven National Laboratory. For ease of future growth and flexibility, almost all software components are open source with very active maintainers. Among them, Linux running on x86 desktop computer, RTAI for real-time response, COMEDI driver for the data acquisition hardware, Qt and PyQt for graphical user interface, PyQwt for plotting, and Python for scripting. The signal (A/D) and energy-reading (IK220 encoder) devices in the PCI computer are also EPICS enabled. The control system scans the monochromator energy through a networked EPICS motor. With the real-time kernel, the system is capable of deterministic data-sampling period of tens of micro-seconds with typical timing-jitter of several micro-seconds. At the same time, Linux is running in other non-real-time processes handling the user-interface. A modern Qt-based controls-frontend enhances productivity. The fast plotting and zooming of data in time or energy coordinates let the experimenters verify the quality of the data before detailed analysis. Python scripting is built-in for automation. The typical data-rate for continuous runs are around 10 M bytes/min

  10. Laboratory EXAFS using photographic method

    International Nuclear Information System (INIS)

    Joshi, S K; Gaur, A; Johari, A; Shrivastava, B D

    2009-01-01

    Laboratory EXAFS facilities have been used since long. However, EXAFS data analysis has not been reported as yet for the spectra recorded photographically. Though from our laboratory we have been reporting various studies employing X-ray spectrographs using the photographic method of registration of EXAFS spectra, but the data has never been analyzed using the Fourier transformation method and fitting with standards. This paper reports the study of copper metal EXAFS spectra at the K-edge recorded photographically employing a 400 mm curved mica crystal Cauchois type spectrograph with 0.5 kW tungsten target X-ray tube. The data obtained in digital form with the help of a microphotometer has been processed using EXAFS data analysis programs Athena and Artemis. The experimental data for copper metal foil have been fitted with the theoretical standards. The results have been compared with those obtained from another laboratory EXAFS set up employing 12 kW Rigaku rotating anode, Johansson-type spectrometer with Si(311) monochromator crystal and scintillation counter. The results have also been compared with those obtained from SSRL. The parameters obtained for the first two shells from the photographic method are comparable with those obtained from the other two methods. The present work shows that the photographic method of registering EXAFS spectra in laboratory set up using fixed target X-ray tubes can also be used for getting structural information at least for the first two coordination shells.

  11. Laboratory EXAFS using photographic method

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, S K [Government College, Badnawar (Dhar)-454660 (India); Gaur, A; Johari, A; Shrivastava, B D, E-mail: joshisantoshk@yahoo.co [School of Studies in Physics, Vikram University, Ujjain-456010 (India)

    2009-11-15

    Laboratory EXAFS facilities have been used since long. However, EXAFS data analysis has not been reported as yet for the spectra recorded photographically. Though from our laboratory we have been reporting various studies employing X-ray spectrographs using the photographic method of registration of EXAFS spectra, but the data has never been analyzed using the Fourier transformation method and fitting with standards. This paper reports the study of copper metal EXAFS spectra at the K-edge recorded photographically employing a 400 mm curved mica crystal Cauchois type spectrograph with 0.5 kW tungsten target X-ray tube. The data obtained in digital form with the help of a microphotometer has been processed using EXAFS data analysis programs Athena and Artemis. The experimental data for copper metal foil have been fitted with the theoretical standards. The results have been compared with those obtained from another laboratory EXAFS set up employing 12 kW Rigaku rotating anode, Johansson-type spectrometer with Si(311) monochromator crystal and scintillation counter. The results have also been compared with those obtained from SSRL. The parameters obtained for the first two shells from the photographic method are comparable with those obtained from the other two methods. The present work shows that the photographic method of registering EXAFS spectra in laboratory set up using fixed target X-ray tubes can also be used for getting structural information at least for the first two coordination shells.

  12. EXAFS spectroscopy of quasicrystals

    International Nuclear Information System (INIS)

    Menushenkov, A. P.; Rakshun, Ya. V.

    2007-01-01

    The results of the investigation of the features of the local structure of quasicrystalline materials by extended X-ray absorption fine structure (EXAFS) spectroscopy with the use of synchrotron radiation are analyzed. The advantages of this method from the point of view of deriving information about the local shifts of the atoms forming an icosahedral structure are demonstrated. The rearrangement of the local environment of copper and iron in Al-Fe-Cu ternary alloys at a transition from the crystalline to the quasicrystalline phase has been investigated. It is established that the nearest copper coordination retains the symmetry characteristic of the crystal; however, rotation and small displacements of copper matrix atoms lead to significant rearrangement of aluminum atoms around iron atoms. As a result, icosahedral clusters with pentagonal symmetry are formed around iron atoms and violation of the translational symmetry is accompanied by the transition of Al-Fe-Cu to the quasicrystalline state

  13. EXAFS studies on the reaction of gold (III) chloride complex ions with sodium hydroxide and glucose.

    Science.gov (United States)

    Pacławski, K; Zajac, D A; Borowiec, M; Kapusta, Cz; Fitzner, K

    2010-11-11

    EXAFS and QEXAFS experiments were carried out at Hasylab laboratory in DESY center (X1 beamline, Hamburg, Germany) to monitor the course of the hydrolysis reactions of [AuCl(4)](-) complex ions as well as their reduction using glucose. As a result, changes in the spectra of [AuCl(4)](-) ions and disappearance of absorption Au-L(3) edge were registered. From the results of the experiments we have carried out, the changes in bond lengths between Au(3+) central ion and Cl(-) ligands as well as the reduction of Au(3+) to metallic form (colloidal gold was formed in the system) are evident. Good quality spectra obtained before and after the reactions gave a chance to determine the bond length characteristic of Au-Cl, Au-OH and Au-Au pairs. Additionally, the obtained results were compared with the simulated spectra of different gold (III) complex ions, possibly present in the solution. Finally, the mechanism of these reactions was suggested. Unfortunately, it was not possible to detect the changes in the structure of gold (III) complex ions within the time of reaction, because of too high rates of both processes (hydrolysis and reduction) as compared with the detection time.

  14. Surface EXAFS - A mathematical model

    International Nuclear Information System (INIS)

    Bateman, J.E.

    2002-01-01

    Extended X-ray absorption fine structure (EXAFS) studies are a powerful technique for studying the chemical environment of specific atoms in a molecular or solid matrix. The study of the surface layers of 'thick' materials introduces special problems due to the different escape depths of the various primary and secondary emission products which follow X-ray absorption. The processes are governed by the properties of the emitted fluorescent photons or electrons and of the material. Their interactions can easily destroy the linear relation between the detected signal and the absorption cross-section. Also affected are the probe depth within the surface and the background superimposed on the detected emission signal. A general mathematical model of the escape processes is developed which permits the optimisation of the detection modality (X-rays or electrons) and the experimental variables to suit the composition of any given surface under study

  15. EXAFS studies of metamict materials

    International Nuclear Information System (INIS)

    Greegor, R.B.; Lytle, F.W.; Ewing, R.C.; Haaker, R.F.

    1984-01-01

    An important approach in the evaluation of crystalline wasteforms for nuclear waste storage is to study the long term stabilities of closely related radioactive mineral species which have become metamict (radiation damaged) and have been exposed to weathering processes for geologic periods of time. The metamictization and alteration effects can then be used for comparison with the results of short term laboratory leaching and irradiation experiments which have been designed to simulate long term effects. Phosphates, the Ti-Nb-Ta complex oxide minerals and various selected silicates are natural analogues for phases in proposed radioactive wasteforms. Because of the geochemical similarities with wasteforms, a study of the metamict state and annealing in complex mineral phosphates, silicates and oxides will yield data that is important in evaluating the long term stability of radioactive wasteforms. The investigation reported here is an application of EXAFS and XANES spectroscopy to the study of the structure of the metamict state. The nearest neighbor environment of Ti and Ca in metamict AB 2 O 6 -type complex oxides has been examined using SSRL Beam Line VII-3 in order to evaluate the effect of alpha-recoil damage on these structures. Comparison of the EXAFS/XANES data for metamict samples with data for annealed and crystalline samples suggests minor changes in the first coordination sphere, Ca-O or Ti-O, (a slight decrease in coordination number and bond lengths, and increased distortion of the coordination polyhedron), but major disruption of the second coordination sphere, for the material in the metamict state. These data suggest a mechanism for the transition from the crystalline to the metamict state in which tilting of cation coordiantion polyhedra is a possible effect of damage caused by alpha-recoil events

  16. (EXAFS) X-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Craievich, A.F.

    1983-01-01

    The technique EXAFS (Extended X-Ray Absorption Fine Structure) is presented and its applications using the synchrotron radiation as an incidente beam in Science of Materials and Biophysics are shown. (L.C.) [pt

  17. EXAFS-spectroscopy on synchrotron radiation beam

    CERN Document Server

    Aksenov, V L; Kuzmin, A Y; Purans, Y

    2001-01-01

    In the review the basis theoretical principles of EXAFS spectroscopy are given, as one of principal directions of an absorption spectroscopy permitting with a high accuracy to gain parameters of the short-range order in multicomponent amorphous and quasi-crystal mediums. The methods of the analysis of EXAFS spectra with allowance of effects of multiply scattering are featured. The exposition of the experimental set-ups, which realize the method of EXAFS spectroscopy on beams of SR, requirement of the monochromatization of radiation beams are given. For investigation of phase transition and external effects the energy-dispersive EXAFS spectrometer is creating at the National center of SR Kurchatov Institute which can measure the EXAFS spectrum with a time resolution 3-5 ms. The experimental results on investigation (by the EXAFS spectroscopy method) of oxides of tungsten and molybdenum are given, which have unique property: the variable valence of an ion of metal is depending on external action. The most inter...

  18. EXAFS cumulants of CdSe

    International Nuclear Information System (INIS)

    Diop, D.

    1997-04-01

    EXAFS functions had been extracted from measurements on the K edge of Se at different temperatures between 20 and 300 K. The analysis of the EXAFS of the filtered first two shells has been done in the wavevector range laying between 2 and 15.5 A -1 in terms of the cumulants of the effective distribution of distances. The cumulants C 3 and C 4 obtained from the phase difference and the amplitude ratio methods have shown the anharmonicity in the vibrations of atoms around their equilibrium position. (author). 13 refs, 3 figs

  19. X-ray absorption spectroscopy (EXAFS)

    International Nuclear Information System (INIS)

    Craievich, A.F.

    1983-01-01

    The experimental technics of Extended X-ray Absorption Fine Structure (EXAFS) is presented and several uses of it in atomic, molecular and bio physics are shown. The recent progresses of this technics, both theoretical and experimental, are discussed and the future perspectives on this subject are commented. (L.C.) [pt

  20. The time-resolved and extreme conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the general-purpose EXAFS bending-magnet beamline BM23

    Energy Technology Data Exchange (ETDEWEB)

    Mathon, O., E-mail: mathon@esrf.fr; Beteva, A.; Borrel, J.; Bugnazet, D.; Gatla, S.; Hino, R.; Kantor, I.; Mairs, T. [European Synchrotron Radiation Facility, CS 40220, 38043 Grenoble Cedex 9 (France); Munoz, M. [European Synchrotron Radiation Facility, CS 40220, 38043 Grenoble Cedex 9 (France); Université Joseph Fourier, 1381 rue de la Piscine, BP 53, 38041 Grenoble Cedex 9 (France); Pasternak, S.; Perrin, F.; Pascarelli, S. [European Synchrotron Radiation Facility, CS 40220, 38043 Grenoble Cedex 9 (France)

    2015-10-17

    BM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high-signal-to-noise ratio EXAFS in a large energy range (5–75 keV), continuous energy scanning for quick-EXAFS on the second timescale and a micro-XAS station delivering a spot size of 4 µm × 4 µm FWHM. BM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high signal-to-noise ratio EXAFS in a large energy range (5–75 keV), continuous energy scanning for quick-EXAFS on the second timescale and a micro-XAS station delivering a spot size of 4 µm × 4 µm FWHM. It is a user-friendly facility featuring a high degree of automation, online EXAFS data reduction and a flexible sample environment.

  1. EXAFS and principal component analysis : a new shell game

    International Nuclear Information System (INIS)

    Wasserman, S.

    1998-01-01

    The use of principal component (factor) analysis in the analysis EXAFS spectra is described. The components derived from EXAFS spectra share mathematical properties with the original spectra. As a result, the abstract components can be analyzed using standard EXAFS methodology to yield the bond distances and other coordination parameters. The number of components that must be analyzed is usually less than the number of original spectra. The method is demonstrated using a series of spectra from aqueous solutions of uranyl ions

  2. The time-resolved and extreme conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the general-purpose EXAFS bending-magnet beamline BM23.

    Science.gov (United States)

    Mathon, O; Beteva, A; Borrel, J; Bugnazet, D; Gatla, S; Hino, R; Kantor, I; Mairs, T; Munoz, M; Pasternak, S; Perrin, F; Pascarelli, S

    2015-11-01

    BM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high signal-to-noise ratio EXAFS in a large energy range (5-75 keV), continuous energy scanning for quick-EXAFS on the second timescale and a micro-XAS station delivering a spot size of 4 µm × 4 µm FWHM. It is a user-friendly facility featuring a high degree of automation, online EXAFS data reduction and a flexible sample environment.

  3. EXAFS of dilute systems: fluorescence detection

    International Nuclear Information System (INIS)

    Hastings, J.B.

    1979-01-01

    Since the first observations of the variation of the absorption coefficient for x-rays above the energy thresholds in the thirties until the early seventies, measurements and analysis of these variations were merely intended for the understanding of the underlying physics. Recently, with the understanding of the information available about the local atomic structure in the neighborhood of the absorbing species and the availability of high intensity synchrotron radiation sources, EXAFS has become a powerful structural tool. In these discussions, the details of the measurements for very dilute species are presented. It is shown that for the more dilute systems the measurement of the emission rather than the direct absorption is a more favorable technique

  4. EXAFS study of plutonium sorption onto kaolinite

    International Nuclear Information System (INIS)

    Reich, T.Y.; Banik, L.; Buda, R.A.; Amayri, S.; Drebert, J.; Kratz, J.V.; Trautmann, N.; Reich, T.; Ageev, A.L.; Korshunov, M.E.

    2007-01-01

    The uptake mechanism of plutonium by kaolinite was investigated by applying X-ray absorption spectroscopy to batch sorption samples (total Pu concentrations 1 and 10 μM; 4 g kaolinite/L in 0.1 M NaClO 4 ; 1 ≤ pH ≤ 9; presence and absence of ambient CO 2 ). For XAFS measurements, one sample was prepared from a Pu(III) solution at pH 6 under argon atmosphere. Three samples were obtained by sorption of Pu(IV) at pH I, 4, and 9 in an air-equilibrated system. The Pu L III -edge XANES spectra indicated that in all samples, including the Pu(III) sample, plutonium is sorbed at the kaolinite surface as Pu(IV). The Pu L III -edge k 3 -weighted EXAFS spectra showed eight oxygen atoms at an average Pu-O distance of 2.3 angstrom. Two Pu atoms were detected at ∼ 3.7 angstrom in all spectra, indicating the formation of polynuclear Pu(IV) species at the kaolinite surface. For the sample prepared from Pu(III) solution, an additional Pu-O shell at 3.2 angstrom was observed. The spectra of samples prepared from Pu(IV) included a Pu-Al/Si co-ordination shell at approximately 3.6 angstrom, indicating formation of inner-sphere sorption complexes. The structural models used in the least-squares fits were confirmed by an alternative EXAFS data analysis approach based on a modified Tikhonov regularization method. (authors)

  5. Comparison of EXAFS Foil Spectra from Around the World

    International Nuclear Information System (INIS)

    Kelly, S.D.; Bare, S.R.; Greenlay, N.; Azevedo, G.; Balasubramanian, M.; Barton, D.; Chattopadhyay, S.; Fakra, S.; Johannessen, B.; Newville, M.; Pena, J.; Pokrovski, G.S; Proux, O.; Priolkar, K.; Ravel, B.; Webb, S.M.

    2010-01-01

    The EXAFS spectra of Cu and Pd foil from many different beamlines and synchrotrons are compared to address the dependence of the amplitude reduction factor (S 0 2 ) on beamline specific parameters. Even though S 0 2 is the same parameter as the EXAFS coordination number, the value for S 0 2 is given little attention, and is often unreported. The S 0 2 often differs for the same material due to beamline and sample attributes, such that no importance is given to S 0 2 -values within a general range of 0.7 to 1.1. EXAFS beamlines have evolved such that it should now be feasible to use standard S 0 2 values for all EXAFS measurements of a specific elemental environment. This would allow for the determination of the imaginary energy (Ei) to account for broadening of the EXAFS signal rather than folding these errors into an effective S 0 2 -value. To test this concept, we model 11 Cu-foil and 6 Pd-foil EXAFS spectra from around the world to compare the difference in S 0 2 - and Ei-values.

  6. The Difficult Chore of Measuring Coordination by EXAFS

    International Nuclear Information System (INIS)

    Ravel, B.; Kelly, S. D.

    2007-01-01

    Neither the theory nor the interpretation of Extended X-Ray-Absorption Fine-Structure (EXAFS) spectroscopy requires assumptions of crystalline symmetry or periodicity. As a result, EXAFS is a tool applied to a wide range of scientific disciplines and to a wide variety of experimental systems. A simple enumeration of the atoms in the coordination environment of the absorber is often the primary goal of an EXAFS experiment. There are, however, a number of pitfalls in the way of an accurate determination of coordination number (CN). These include statistical limitations of the EXAFS fitting problem, empirical effects due to sample preparation, and the assumptions made about the physical structure surrounding the absorber in the course of data analysis. In this paper we examine several of these pitfalls and their effects upon the determination of CN. Where possible, we offer suggestions for avoiding or mitigating the pitfalls. We hope this paper will help guide the general EXAFS practitioner through the difficult chore of accurately determining CN

  7. Composing complex EXAFS problems with severe information constraints

    International Nuclear Information System (INIS)

    Ravel, B

    2009-01-01

    In recent work, a model for the structural environment of Hg bound to a catalytic DNA sensor was proposed on the basis of EXAFS data analysis. Although severely constrained by limited data quality and scant supporting structural data, a compelling structural model was found which agreed with a similar but less detailed model proposed on the basis on NMR data. I discuss in detail the successes and limitations of the analytical strategy that were implemented in the earlier work. I then speculate on future software requirements needed to make this and similarly complex analytical strategies more available to the wider audience of EXAFS practitioners.

  8. Automating an EXAFS facility: hardware and software considerations

    International Nuclear Information System (INIS)

    Georgopoulos, P.; Sayers, D.E.; Bunker, B.; Elam, T.; Grote, W.A.

    1981-01-01

    The basic design considerations for computer hardware and software, applicable not only to laboratory EXAFS facilities, but also to synchrotron installations, are reviewed. Uniformity and standardization of both hardware configurations and program packages for data collection and analysis are heavily emphasized. Specific recommendations are made with respect to choice of computers, peripherals, and interfaces, and guidelines for the development of software packages are set forth. A description of two working computer-interfaced EXAFS facilities is presented which can serve as prototypes for future developments. 3 figures

  9. EXAFS determination of cation local order in layered perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Montero C, M. E.; Fuentes M, L.; Duarte M, J. A.; Fuentes C, L. [Centro de Investigacion en Materiales Avanzados S. C., Miguel de Cervantes Saavedra 120, Complejo Industrial Chihuahua, 31109 Chihuahua (Mexico); Garcia G, M. [Instituto de Fisica, UNAM, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Mehta, A.; Webb, S. [Stanford Synchrotron Radiation Laboratory, CA (United States)

    2008-02-15

    EXAFS analysis of Bi{sub 6}Ti{sub 3}Fe{sub 2}O{sub 18} Aurivillius ceramic was performed to elucidate the local environment of Fe cations. Experiments were performed at Stanford Synchrotron Radiation Laboratory, at T = 10, 30, 50, 75, 100 and 298 K, in fluorescence regime. EXAFS spectra were processed using the ab initio multiple scattering program FEFF6. Distances among representative atomic pairs were refined. As a basic result, the previous hypothesis suggested by X-ray diffraction experiments, regarding a preference of iron atoms for the centered perovskite layer of the unit cell, was confirmed. (Author)

  10. EXAFS as a tool for catalyst characterization: a review of the data analysis methods

    Directory of Open Access Journals (Sweden)

    NORONHA F. B.

    1999-01-01

    Full Text Available A review of the EXAFS data analysis methods is presented. A detailed description of the EXAFS signal extraction and the Fourier transform of the data are discussed. The procedure for determining interatomic distances, coordination numbers and disorder effects from EXAFS data is described. This paper also discusses the data analysis statistics. Finally, one example of catalyst characterization by the EXAFS technique is reported.

  11. Multifunctional synchrotron spectrometer of NRC Kurchatov Institute. Part 1. EXAFS in dispersive mode

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Tyutyunnikov, S.I.; Shalyapin, V.N.; Belyaev, A.D.; Artem'ev, A.N.; Kirillov, B.F.; Demkiv, A.A.; Knyazev, G.A.; Koval'chuk, M.V.; Artem'ev, N.A.

    2017-01-01

    The improved X-ray optical scheme, the system of registration and measurement procedure of multifunctional synchrotron radiation spectrometer in dispersive EXAFS mode are described. The results of the energy permission measurements of spectrometer are given. The advantages and disadvantages in the traditional and dispersion schematics of spectrometers EXAFS are analyzed. Examples of the EXAFS spectra measured in the dispersion mode are given.

  12. Pressure effects in Debye-Waller factors and in EXAFS

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen Van Hung, E-mail: hungnv@vnu.edu.v [University of Science, VNU Hanoi, 334 Nguyen Trai, Thanh Xuan, Hanoi (Viet Nam); Vu Van Hung [Hanoi National University of Education, 136 Xuan Thuy, Cau Giay, Hanoi (Viet Nam); Ho Khac Hieu [University of Science, VNU Hanoi, 334 Nguyen Trai, Thanh Xuan, Hanoi (Viet Nam); National University of Civil Engineering, 55 Giai Phong, Hai Ba Trung, Hanoi (Viet Nam); Frahm, Ronald R. [Bergische Universitaet-Gesamthochschule Wuppertal, FB: 8-Physik, Gauss Strasse 20, 42097 Wuppertal (Germany)

    2011-02-01

    Anharmonic correlated Einstein model (ACEM) and statistical moment method (SMM) have been developed to derive analytical expressions for pressure dependence of the lattice bond length, effective spring constant, correlated Einstein frequency and temperature, Debye-Waller factors (DWF) or second cumulant, first and third cumulants in Extended X-ray Absorption Fine Structure (EXAFS) at a given temperature. Numerical results for pressure-dependent DWF of Kr and Cu agree well with experiment and other theoretical values. Simulated EXAFS of Cu and its Fourier transform magnitude using our calculated pressure-induced change in the 1st shell are found to be in a reasonable agreement with those using X-ray diffraction (XRD) experimental results. -- Research Highlights: {yields} We have developed anharmonic correlated Einstein model and statistical moment method. {yields} The pressure effects in cumulants including DWF and in EXAFS has been investigated. {yields} Calculated pressure-dependent DWF for Kr, Cu agree with experiment and other results. {yields} Simulated EXAFS and Fourier transform magnitude of Cu agree with those using XRD data.

  13. Pressure effects in Debye-Waller factors and in EXAFS

    International Nuclear Information System (INIS)

    Nguyen Van Hung; Vu Van Hung; Ho Khac Hieu; Frahm, Ronald R.

    2011-01-01

    Anharmonic correlated Einstein model (ACEM) and statistical moment method (SMM) have been developed to derive analytical expressions for pressure dependence of the lattice bond length, effective spring constant, correlated Einstein frequency and temperature, Debye-Waller factors (DWF) or second cumulant, first and third cumulants in Extended X-ray Absorption Fine Structure (EXAFS) at a given temperature. Numerical results for pressure-dependent DWF of Kr and Cu agree well with experiment and other theoretical values. Simulated EXAFS of Cu and its Fourier transform magnitude using our calculated pressure-induced change in the 1st shell are found to be in a reasonable agreement with those using X-ray diffraction (XRD) experimental results. -- Research Highlights: → We have developed anharmonic correlated Einstein model and statistical moment method. → The pressure effects in cumulants including DWF and in EXAFS has been investigated. → Calculated pressure-dependent DWF for Kr, Cu agree with experiment and other results. → Simulated EXAFS and Fourier transform magnitude of Cu agree with those using XRD data.

  14. Investigation of radiation defects in solids using the EXAFS method

    International Nuclear Information System (INIS)

    Eritsyan, G.N.

    1983-01-01

    The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons

  15. Study of the Chemical Mechanism Involved in the Formation of Tungstite in Benzyl Alcohol by the Advanced QEXAFS Technique

    DEFF Research Database (Denmark)

    Olliges‐Stadler, Inga; Stötzel, Jan; Koziej, Dorota

    2012-01-01

    Insight into the complex chemical mechanism for the formation of tungstite nanoparticles obtained by the reaction of tungsten hexachloride with benzyl alcohol is presented herein. The organic and inorganic species involved in the formation of the nanoparticles were studied by time‐dependent gas......‐scanning extended X‐ray absorption fine structure spectroscopy enabled the time‐dependent evolution of the starting compound, the intermediates and the product to be monitored over the full reaction period. The reaction starts with fast chlorine substitution and partial reduction during the dissolution...

  16. Silicon Detector System for High Rate EXAFS Applications.

    Science.gov (United States)

    Pullia, A; Kraner, H W; Siddons, D P; Furenlid, L R; Bertuccio, G

    1995-08-01

    A multichannel silicon pad detector for EXAFS (Extended X-ray Absorption Fine Structure) applications has been designed and built. The X-ray spectroscopic measurements demonstrate that an adequate energy resolution of 230 eV FWHM (corresponding to 27 rms electrons in silicon) can be achieved reliably at -35 °C. A resolution of 190 eV FWHM (corresponding to 22 rms electrons) has been obtained from individual pads at -35 °C. At room temperature (25 °C) an average energy resolution of 380 eV FWHM is achieved and a resolution of 350 eV FWHM (41 rms electrons) is the best performance. A simple cooling system constituted of Peltier cells is sufficient to reduce the reverse currents of the pads and their related shot noise contribution, in order to achieve resolutions better than 300 eV FWHM which is adequate for the EXAFS applications.

  17. EXAFS investigation on microstructure of La-based alloy deuteride

    CERN Document Server

    Chen Bo Fei; Xie Chao Mei; Chen Xi Ping; Liu Li Juan; Xie Ya Ning; Hu Tian Dou; Zhang Jing

    2002-01-01

    Extended X-ray absorption fine structure (EXAFS) spectra were measured to investigate the microstructure of La-based alloy deuteride. The radial structural functions of LaNi sub 4 sub . sub 2 sub 5 Al sub 0 sub . sub 7 sub 5 D sub x samples were obtained and the comparisons among different samples were performed. The results show that removal of deuterium is fast in La-Ni-Al hydrogen storage alloys under non-airtight condition

  18. EXAFS investigations of Cu-Mg-O compound

    CERN Document Server

    Sidorenko, A F; Babanov, Y A; Naumov, S V; Samokhvalov, A A

    2001-01-01

    The interest to systems containing copper oxide is connected with the problem of high-temperature superconductivity because of the closeness of its basic physical properties and properties of superconductor mother Cu-compounds. In this work, EXAFS study of the Cu sub 0 sub . sub 2 Mg sub 0 sub . sub 8 O compound is presented. A new iterative algorithm of the solution of ill-posed problem on determining three partial pair correlation functions from one EXAFS-data set near the Cu K-edge is described. The results of X-ray scattering study of a given sample show a presence of a single phase with the MgO structure and a lattice parameter of 4.219 A instead of 4.208 A for pure MgO. From the EXAFS investigations, we find the local distortion of the lattice. We revealed that the short range order differs both from a hypothetical alloy with the MgO structure and from copper oxide.

  19. Temperature-dependent magnetic EXAFS investigation of Gd

    CERN Document Server

    Wende, H; Poulopoulos, P N; Rogalev, A; Goulon, J; Schlagel, D L; Lograsso, T A; Baberschke, K

    2001-01-01

    Magnetic EXAFS (MEXAFS) is the helicity-dependent counterpart of the well-established EXAFS technique. By means of MEXAFS it is possible not only to analyze the local magnetic structure but also to learn about magnetic fluctuations. Here we present the MEXAFS of a Gd single crystal at the L sub 3 sub , sub 2 -edges in the temperature range of 10-250 K. For the first time MEXAFS was probed over a large range in reduced temperature of 0.04<=T/T sub C<=0.85 with T sub C =293 K. We show that the vibrational damping described by means of a Debye temperature of theta sub D =160 K must be taken into account for the spin-dependent MEXAFS before analyzing magnetic fluctuations. For a detailed analysis of the MEXAFS and the EXAFS, the experimental data are compared to ab initio calculations. This enables us to separate the individual single- from the multiple-scattering contributions. The MEXAFS data have been recorded at the ID 12A beamline of the European Synchrotron Radiation Facility (ESRF). To ensure that th...

  20. Spatial structure of transition metal complexes in solution determined by EXAFS spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Erenburg, S.B. E-mail: simon@che.nsk.su; Bausk, N.V.; Zemskova, S.M.; Mazalov, L.N

    2000-06-21

    CdK EXAFS, ZnK and CuK EXAFS and XANES spectra were measured for solutions of cadmium, zinc and copper dialkyldithiocarbamates in organic solvents with varying donating abilities: tributylphosphine, methylene chloride, benzene, dibutylsulfide, pyridine, dimethylsulfoxide and for some model compounds. The parameters of the local surroundings of the Cd, Zn and Cu atoms for complex forms in solutions were determined using EXAFS spectroscopy. Spatial structure models of the complex forms in a metal chelate - nonaqueous solvent system are suggested.

  1. Spatial structure of transition metal complexes in solution determined by EXAFS spectroscopy

    International Nuclear Information System (INIS)

    Erenburg, S.B.; Bausk, N.V.; Zemskova, S.M.; Mazalov, L.N.

    2000-01-01

    CdK EXAFS, ZnK and CuK EXAFS and XANES spectra were measured for solutions of cadmium, zinc and copper dialkyldithiocarbamates in organic solvents with varying donating abilities: tributylphosphine, methylene chloride, benzene, dibutylsulfide, pyridine, dimethylsulfoxide and for some model compounds. The parameters of the local surroundings of the Cd, Zn and Cu atoms for complex forms in solutions were determined using EXAFS spectroscopy. Spatial structure models of the complex forms in a metal chelate - nonaqueous solvent system are suggested

  2. EXAFS analysis of uranium speciation in plants using the difference technique

    International Nuclear Information System (INIS)

    Rossberg, A.; Reich, T.; Guenther, A.; Bernhard, G.

    2002-01-01

    An EXAFS spectrum is the sum of the signals of scattering contributions from single atoms and multiple scattering (MS) between atoms. The scattering contributions with high intensity are the major and such with low intensity are the minor components in an EXAFS spectrum. A chi-squared fit algorithm is not sensitive enough to the minor components. A difference technique has been developed /1/ to isolate the minor components from the whole EXAFS spectrum to increase the accuracy in determinating of their EXAFS structural parameters. (orig.)

  3. Structural changes of noble metal catalysts during ignition and extinction of the partial oxidation of methane studied by advanced QEXAFS techniques

    DEFF Research Database (Denmark)

    Grunwaldt, Jan-Dierk; Beier, M.; Kimmerle, B.

    2009-01-01

    The dynamics of the ignition and extinction of the catalytic partial oxidation (CPO) of methane to hydrogen and carbon monoxide over Pt-Rh/Al2O3 and Pt/Al2O3 were studied in the subsecond timescale using quick-EXAFS with a novel cam-driven X-ray monochromator employing Si(111) and Si(311) crystals...... to discuss the potential and limitation of this technique in catalysis and related areas. With respect to the noble metal catalysed partial oxidation of methane, several interesting observations were made: structural changes during ignition were-independent of the chosen reaction conditions......-significantly faster than during the extinction of the reaction. The dynamic behavior of the catalysts was dependent on the flow conditions and the respective noble metal component(s). Higher reaction gas flow led to a faster ignition process. While the ignition over Pt-Rh/Al2O3 occurred at lower temperature than over...

  4. Silicon Detector System for High Rate EXAFS Applications

    OpenAIRE

    Pullia, A.; Kraner, H. W.; Siddons, D. P.; Furenlid, L. R.; Bertuccio, G.

    1995-01-01

    A multichannel silicon pad detector for EXAFS (Extended X-ray Absorption Fine Structure) applications has been designed and built. The X-ray spectroscopic measurements demonstrate that an adequate energy resolution of 230 eV FWHM (corresponding to 27 rms electrons in silicon) can be achieved reliably at −35 °C. A resolution of 190 eV FWHM (corresponding to 22 rms electrons) has been obtained from individual pads at −35 °C. At room temperature (25 °C) an average energy resolution of 380 eV FWH...

  5. Moessbauer and EXAFS spectroscopy investigation of iron and arsenic adsorption to lettuce leaves

    International Nuclear Information System (INIS)

    Vasconcelos, Igor F.; Silva, Gabriela C.; Carvalho, Regina P.; Dantas, Maria Sylvia S.; Ciminelli, Virginia S. T.

    2010-01-01

    The accumulation of iron and arsenic from aqueous solution by lettuce leaves biomass was investigated using Moessbauer and EXAFS spectroscopic techniques. Moessbauer spectroscopy results show that iron is oxidized during sorption while EXAFS results indicate that iron is coordinated by approximately 6 oxygen and 2 carbon atoms while arsenic is coordinated by approximately 4 oxygen atoms with iron as a second neighbor.

  6. Moessbauer and EXAFS spectroscopy investigation of iron and arsenic adsorption to lettuce leaves

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Igor F., E-mail: ifvasco@ufc.br [Universidade Federal do Ceara, Dep. Eng. Metalurgica e de Materiais (Brazil); Silva, Gabriela C.; Carvalho, Regina P.; Dantas, Maria Sylvia S.; Ciminelli, Virginia S. T. [Universidade Federal de Minas Gerais, Dep. Eng. Metalurgica e de Materiais (Brazil)

    2010-01-15

    The accumulation of iron and arsenic from aqueous solution by lettuce leaves biomass was investigated using Moessbauer and EXAFS spectroscopic techniques. Moessbauer spectroscopy results show that iron is oxidized during sorption while EXAFS results indicate that iron is coordinated by approximately 6 oxygen and 2 carbon atoms while arsenic is coordinated by approximately 4 oxygen atoms with iron as a second neighbor.

  7. EXAFS investigations on PbMoO4 single crystals grown under ...

    Indian Academy of Sciences (India)

    Abstract. Extended X-ray absorption fine structure (EXAFS) measurements on PbMoO4 (LMO) crystals have been performed at the recently-commissioned dispersive EXAFS beamline (BL-8) of INDUS-2 Synchrotron facility at Indore, India. The LMO samples were prepared under three different conditions viz. (i) grown from ...

  8. Zn-K edge EXAFS study of human nails

    Energy Technology Data Exchange (ETDEWEB)

    Katsikini, M; Mavromati, E; Pinakidou, F; Paloura, E C [School of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Gioulekas, D, E-mail: katsiki@auth.g [Medical School, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2009-11-15

    Extended X-ray absorption fine structure (EXAFS) spectroscopy at the Zn - K edge is applied for the study of the bonding geometry of Zn in human nails. The studied nail clippings belong to healthy donors and donors who suffer from lung diseases. Fitting of the first nearest neighboring shell of Zn reveals that it is bonded with N and S, at distances that take values in the ranges 2.00-2.04 A and 2.23-2.28A, respectively. Zn is four - fold coordinated and the ratio of the number of sulfur and nitrogen atoms (N{sub S}/N{sub N}) in the first coordination shell ranges from 0.52 to 1. The sample that belongs to the donor who suffers from lung fibrosis, a condition that is related to keratinization of the lung tissue, is characterized by the highest number of N{sub S}/N{sub N}. Simulation, using the FEFF8 code, of the Zn - K edge EXAFS spectra with models of tetrahedrally coordinated Zn with 1 (or 2) cysteine and 3 (or 2) histidines is satisfactory.

  9. Manganese in photosynthetic oxygen evolution: An edge and EXAFS study

    International Nuclear Information System (INIS)

    Yachandra, V.K.; Guiles, R.D.; McDermott, A.; Britt, R.D.; Dexheimer, S.L.; Saver, K.; Klein, M.P.

    1985-01-01

    The authors edge studies have previously shown that the Mn edges in photosynthetic samples in the S 1 and S 2 states fall into the range for Mn III and Mn IV complexes, and that the K-edge energy increases appreciably on advancing S 1 to S 2 . This was the first evidence that manganese is directly involved in the storage of oxidizing equivalents. More recently, they have extended this result with better quality data from both spinach and a thermophilic cyanobacterium. The newer results show an interesting structure to the edges, including a 1s to 3d transition. The EXAFS results for spinach membranes show that the salient features of the Mn structure are the same in the S 1 and S 2 states. These features are a Mn neighbor at approx. =2.7 A and O or N neighbors at approx. =1.75 A and approx. =2.0 A. The EXAFS spectrum of the S 1 state of the thermophilic blue green algae are strikingly similar to that of spinach

  10. SAXS and EXAFS studies of ion beam synthesized Au nanocrystals

    International Nuclear Information System (INIS)

    Kluth, P.; Johannessen, B.; Cookson, D.J.; Foran, G.J.; Ridgway, M.C.

    2006-01-01

    We have used small-angle X-ray scattering (SAXS) and extended X-ray absorption fine structure (EXAFS) spectroscopy to investigate Au nanocrystals (NCs) fabricated by high dose ion implantation into thin SiO 2 and subsequent annealing at different temperatures. Size distributions were determined from SAXS and structural parameters were extracted from EXAFS measurements, the latter analyzed as a function of NC size. Increasing implantation dose leads to an increasing average NC size and broadening of the size distribution. A significant size-dependent bond length contraction with respect to bulk material was observed. For samples annealed at 1100 deg. C our analysis suggests that an increased structural disorder is predominantly located at the NC surface. Post-implantation annealing at temperatures of 500 deg. C and 800 deg. C for 1 h in forming gas had no detectable influence on the NC size distribution, however, a significant influence on the structural parameters, in particular increased disorder was observed. This is potentially the result of stress induced disorder due to the different thermal expansion of the NC and matrix materials

  11. MULTI ELEMENT SI SENSOR WITH READOUT ASIC FOR EXAFS SPECTROSCOPY.

    Energy Technology Data Exchange (ETDEWEB)

    DE GERONIMO,G.; O CONNOR,P.; BEUTTENMULLER,R.H.; LI,Z.; KUCZEWSKI,A.J.; SIDDONS,D.P.

    2002-09-09

    Extended X-ray Absorption Fine Structure (EXAFS) experiments impose stringent requirements on a detection system, due to the need for processing ionizing events at a high rate, typically above of 10Mcps/cm{sup 2}, and with a high resolution, typically better than 300eV. The detection system here presented is being developed targeting these stringent requirements. It is the result of a cooperation between the Instrumentation Division and the National Synchrotron Light Source (NSLS) of the Brookhaven National Laboratory (BNL). The system is composed of a multi-element Si sensor with dedicated per pixel electronics. The combination of high rate, high resolution and moderate complexity makes this system attractive when compared to other multi-element solutions. In sections 2, 3 and 4 the sensor, the interconnect and the electronics are briefly described. Section 5 reports on the first experimental results.

  12. Radiation damage in A-15 materials: EXAFS studies

    International Nuclear Information System (INIS)

    Knapp, G.S.; Kampwirth, R.T.; Georgopoulos, P.; Brown, B.S.

    1980-01-01

    EXAFS measurements are useful in determining the local atomic environment of a particular element in a solid. Since there has been some controversy about the nature of the defects produced in A-15 materials by radiation damage, such studies were carried out on some A-15 compounds, V 3 Ga which was damaged by neutrons, as well as Nb 3 Ge damaged by 2.5 MeV a particles. In the V 3 Ga sample, site exchange disorder seems to be the most important result of the neutron damage with less than 20% of the vanadium atoms on wrong sites. However, in the Nb 3 Ge samples in addition to site exchange disorder, an unusual splitting of the first near-neighbor distance between the Ge and Nb is found. This splitting, approximately 0.2 A, may explain the large Debye Waller factors observed by Burbank et al

  13. Application of a high intensity laboratory X-ray source to EXAFS spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, G G; Deslattes, R D [National Bureau of Standards, Washington, DC (USA)

    1982-02-15

    A practically oriented summary for the design and operation of a high-performance laboratory EXAFS system is presented. Emphasis is on an evaluation of total system performance, including both geometrical and crystal diffraction effects.

  14. Predetermining acceptable noise limits of EXAFS spectra in the limit of stochastic noise

    International Nuclear Information System (INIS)

    Hu, Yung-Jin; Booth, Corwin H

    2009-01-01

    The effect of stochastic noise on Extended X-ray Absorption Fine Structure (EXAFS) data measurement, analysis, and fitting is discussed. Stochastic noise reduces the ability to uniquely fit a calculated model to measured EXAFS data. Such noise can be reduced by common methods that increase the signal-to-noise ratio; however, these methods are not always practical. Therefore, predetermined, quantitative knowledge of the level of acceptable stochastic noise when fitting for a particular model system is essential in maximizing the chances of a successful EXAFS experiment and minimizing wasted beamtime. This paper outlines a method to estimate, through simulation, the acceptable level of stochastic noise in EXAFS spectra that still allows a successful test of a proposed model compound.

  15. Exafs studies of coprecipitation and adsorption reactions of Tc

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, D.J.; Jones, M.J.; Livens, F.R.; Collison, D. [Manchester Univ. (United Kingdom). Dept. of Chemistry; Pattrick, R.A.D. [Manchester Univ., Dept. of Earth Sciences (United Kingdom); Charnock, J.M. [CLRC Daresbury Laboratoire, Warrington Cheshire (United Kingdom)

    2000-07-01

    Adsorption and coprecipitation reactions may be a simple way of removing [TcO{sub 4}]{sup -} from aqueous solution. The effectiveness of a range of potential adsorbents and precipitants has been evaluated and some are capable of near quantitative (>98%) removal of [TcO{sub 4}){sup -} from solution. X-ray absorption near edge structure (XANES) has been used to determine Tc oxidation states and extended X-ray absorption fine structure spectroscopy (EXAFS) has been used to identify the local environment of Tc. The absorption edge position has been determined, using [PPh{sub 4}][TcO{sub 4}], TcS{sub 2} and Tc{sub 2}S{sub 7} as model compounds, and is diagnostic of Tc oxidation state. In a series of experiments investigating FeS coprecipitation, Tc was reduced to oxidation state (IV) and its local environment resembled that in TcO{sub 2} (6 O atoms at approximately 2.0 Angstrom). (authors)

  16. EXAFS and XANES analysis of oxides at the nanoscale

    Directory of Open Access Journals (Sweden)

    Alexei Kuzmin

    2014-11-01

    Full Text Available Worldwide research activity at the nanoscale is triggering the appearance of new, and frequently surprising, materials properties in which the increasing importance of surface and interface effects plays a fundamental role. This opens further possibilities in the development of new multifunctional materials with tuned physical properties that do not arise together at the bulk scale. Unfortunately, the standard methods currently available for solving the atomic structure of bulk crystals fail for nanomaterials due to nanoscale effects (very small crystallite sizes, large surface-to-volume ratio, near-surface relaxation, local lattice distortions etc.. As a consequence, a critical reexamination of the available local-structure characterization methods is needed. This work discusses the real possibilities and limits of X-ray absorption spectroscopy (XAS analysis at the nanoscale. To this end, the present state of the art for the interpretation of extended X-ray absorption fine structure (EXAFS is described, including an advanced approach based on the use of classical molecular dynamics and its application to nickel oxide nanoparticles. The limits and possibilities of X-ray absorption near-edge spectroscopy (XANES to determine several effects associated with the nanocrystalline nature of materials are discussed in connection with the development of ZnO-based dilute magnetic semiconductors (DMSs and iron oxide nanoparticles.

  17. The thermal behaviour of cuprite: An XRD-EXAFS combined approach

    International Nuclear Information System (INIS)

    Dapiaggi, M.; Tiano, W.; Artioli, G.; Sanson, A.; Fornasini, P.

    2003-01-01

    Cuprite (Cu 2 O) is a low thermal expansion material with a negative thermal expansion coefficient below room temperature. Its peculiar thermal behaviour encompasses the increase of the shear modulus with increasing temperature, and the presence of rather intense symmetry-forbidden eeo reflections below room temperature. The thermal expansion of cuprite was studied at low temperature (between 5 and 298 K) by means of high-resolution (10 -5 A) X-ray powder diffraction at European Synchrotron Radiation Facility (Grenoble, BM16) and extended X-ray absorption fine structure (EXAFS) (BM29). Negative thermal expansion is confirmed up to 200 K, by EXAFS as well as by XRD measurements, and no sign of transition was found in XRD data. The comparison between EXAFS and XRD results provides a valuable insight into vibrational behaviour of cuprite at low temperature

  18. EXAFS study on dynamic structural property of porous morph-genetic SiC

    International Nuclear Information System (INIS)

    Ding, J.; Sun, B.H.; Fan, T.X.; Zhang, D.; Kamada, M.; Ogawa, H.; Guo, Q.X.

    2005-01-01

    Novel porous morph-genetic silicon carbide has been fabricated through sintering treatment, after infiltrating the methyl organic silicone resin to the bio-template. Its dynamic transition of structure during sintering process is investigated by extended X-ray absorption fine structure (EXAFS) for the first time. By analyzing Si K-edge EXAFS, it is found that the coordination number of the nearest C shell remains almost unchanged while that of the nearest Si shell dramatically changes when the structure is transformed from amorphous into crystalline state

  19. Characterisation of zinc in slags originated from a contaminated sediment by coupling /μ-PIXE, /μ-RBS, /μ-EXAFS and powder EXAFS spectroscopy

    Science.gov (United States)

    Isaure, M. P.; Laboudigue, A.; Manceau, A.; Sarret, G.; Tiffreau, C.; Trocellier, P.

    2001-07-01

    Depositing dredged sediments on soils is usual but it is a hazardous practice for the local environment when these sediments are polluted by heavy metals. This chemical hazard can be assessed by determining the speciation of metals. In this study, slags highly polluted with Zn and originated from a contaminated dredged sediment were investigated. Zn speciation was studied by laterally resolved techniques such as μ-particle induced X-ray emission (μ-PIXE), μ-Rutherford backscattering spectrometry (μ-RBS), μ-extended X-ray absorption fine structure (μ-EXAFS), and bulk analyses such as powder EXAFS spectroscopy. μ-PIXE and μ-RBS results showed that high concentrations of Zn were associated with S in localised areas at the surface of the slags while moderate amounts of Zn were mainly associated with Fe in the matrix. EXAFS results allowed to identify ZnS and Zn sorbed on ferrihydrite (5Fe 2O 3·9H 2O), proxy for iron oxy-hydroxides, as the main Zn-bearing phases. The occurrence of this Zn-iron oxy-hydroxide is interpreted as a mobilisation of Zn released from ZnS oxidation.

  20. Characterisation of zinc in slags originated from a contaminated sediment by coupling μ-PIXE, μ-RBS, μ-EXAFS and powder EXAFS spectroscopy

    International Nuclear Information System (INIS)

    Isaure, M.P.; Laboudigue, A.; Manceau, A.; Sarret, G.; Tiffreau, C.; Trocellier, P.

    2001-01-01

    Depositing dredged sediments on soils is usual but it is a hazardous practice for the local environment when these sediments are polluted by heavy metals. This chemical hazard can be assessed by determining the speciation of metals. In this study, slags highly polluted with Zn and originated from a contaminated dredged sediment were investigated. Zn speciation was studied by laterally resolved techniques such as μ-particle induced X-ray emission (μ-PIXE), μ-Rutherford backscattering spectrometry (μ-RBS), μ-extended X-ray absorption fine structure (μ-EXAFS), and bulk analyses such as powder EXAFS spectroscopy. μ-PIXE and μ-RBS results showed that high concentrations of Zn were associated with S in localised areas at the surface of the slags while moderate amounts of Zn were mainly associated with Fe in the matrix. EXAFS results allowed to identify ZnS and Zn sorbed on ferrihydrite (5Fe 2 O 3 ·9H 2 O), proxy for iron oxy-hydroxides, as the main Zn-bearing phases. The occurrence of this Zn-iron oxy-hydroxide is interpreted as a mobilisation of Zn released from ZnS oxidation

  1. In situ EXAFS study of Ru-containing electrocatalysts of oxygen reduction

    International Nuclear Information System (INIS)

    Malakhov, I.V.; Nikitenko, S.G.; Savinova, E.R.; Kochubey, D.I.; Alonso-Vante, N.

    2000-01-01

    The series of Ru chalcogenide compounds is obtained by varying the nature of the chalcogen with the transition metal (Ru) matrix. The EXAFS technique reveals that the electrocatalytic centre is Ru in a cluster matrix. Furthermore, a reversible change in the structure of the active centre as a function of the applied electrode potential appears

  2. Structural characterization of Am(III) formate complexes. Combining EXAFS spectroscopy with DFT and thermodynamical calculations

    Energy Technology Data Exchange (ETDEWEB)

    Rossberg, Andre [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Molecular Structures; Froehlich, D.R. [Heidelberg Univ. (Germany). Physikalisch-Chemisches Inst.

    2017-06-01

    We used iterative transformation factor analysis (ITFA) in order to isolate the EXAFS spectral contributions of the complexing ligand from a Am(III)/formate pH-series. Thermodynamic calculations were used as constraint for ITFA and for density functional theory (DFT) calculations to identify the coordination mode within the formed complexes.

  3. EXAFS: New tool for study of battery and fuel cell materials

    Science.gov (United States)

    Mcbreen, James; Ogrady, William E.; Pandya, Kaumudi I.

    1987-01-01

    Extended X ray absorption fine structure (EXAFS) is a powerful technique for probing the local atomic structure of battery and fuel cell materials. The major advantages of EXAFS are that both the probe and the signal are X rays and the technique is element selective and applicable to all states of matter. This permits in situ studies of electrodes and determination of the structure of single components in composite electrodes, or even complete cells. EXAFS specifically probes short range order and yields coordination numbers, bond distances, and chemical identity of nearest neighbors. Thus, it is ideal for structural studies of ions in solution and the poorly crystallized materials that are often the active materials or catalysts in batteries and fuel cells. Studies on typical battery and fuel cell components are used to describe the technique and the capability of EXAFS as a structural tool in these applications. Typical experimental and data analysis procedures are outlined. The advantages and limitations of the technique are also briefly discussed.

  4. EXAFS study of Mo2N and Mo nitrides supported on zeolites

    International Nuclear Information System (INIS)

    Liu Zhenlin; Meng Ming; Fu Yilu; Jiang Ming; Hu Tiandou; Xie Yaning; Liu Tao

    2002-01-01

    In the present study, the reaction is applied to prepare molybdenum nitrides with high surface area, and zeolites are used as supports. The EXAFS of the Mo K-absorption edge is measured and the change of coordination environment of Mo atoms before and after the nitridation is revealed

  5. EXAFS, Determination of Short Range Order and Local Structures in Materials

    NARCIS (Netherlands)

    Koningsberger, D.C.; Prins, R.

    1981-01-01

    Extended X-ray Absorption Fine Structure (EXAFS) is a powerful method of determining short range order and local structures in materials using X-ray photons produced by a synchrotron light source, or in-house by a high intensity rotating anode X-ray generator. The technique has provided valuable

  6. EXAFS Studies of Ga Doped Pb1-xMnxTe

    International Nuclear Information System (INIS)

    Radisavljevic, I.; Ivanovic, N.; Novakovic, N.; Romcevic, N.; Mahnke, H.-E.

    2007-01-01

    We have employed the X-Rays Absorption Fine Structure (EXAFS) technique to resolve the local structure of Pb1-xMnxTe (Ga) in order to provide answers on questions concerning the exact positions and charge states of constitutive and impurity atoms, possibilities and features of their ordering and (or) clustering, as well as configurational and thermal disorder in the system

  7. The structural analysis of zinc borate glass by laboratory EXAFS and X-ray diffraction measurements

    International Nuclear Information System (INIS)

    Kajinami, Akihiko; Harada, Yasushi; Inoue, Shinsuke; Deki, Shigehito; Umesaki, Norimasa

    1999-01-01

    The structure of zinc borate glass has been investigated by laboratory EXAFS and X-ray diffraction measurement as preliminary investigations for the detailed study in SPring-8. The zinc borate glass was prepared in the range from 40 to 65 mol% of zinc oxide content. The X-ray diffraction was measured by horizontal θ-θ goniometer with 60 kV and 300 mA output of Mo target. The EXAFS of zinc borate glass was measured by laboratory EXAFS system with 20 kV, 100 mA output of Mo target for the K absorption edge of zinc atom. From the X-ray diffraction and the EXAFS measurements, it is found that the zinc ion is surrounded by four oxygen atoms and formed a tetrahedral structure whose (Zn-O) distance is about 2 A and that the structure is unchanged with the zinc oxide content. The diffraction data show that the neighboring structure of boron atom transforms from BO 4 tetrahedra to BO 3 tetragonal planar structure with increasing of the zinc oxide content. (author)

  8. PySpline: A Modern, Cross-Platform Program for the Processing of Raw Averaged XAS Edge and EXAFS Data

    International Nuclear Information System (INIS)

    Tenderholt, Adam; Hedman, Britt; Hodgson, Keith O.

    2007-01-01

    PySpline is a modern computer program for processing raw averaged XAS and EXAFS data using an intuitive approach which allows the user to see the immediate effect of various processing parameters on the resulting k- and R-space data. The Python scripting language and Qt and Qwt widget libraries were chosen to meet the design requirement that it be cross-platform (i.e. versions for Windows, Mac OS X, and Linux). PySpline supports polynomial pre- and post-edge background subtraction, splining of the EXAFS region with a multi-segment polynomial spline, and Fast Fourier Transform (FFT) of the resulting k3-weighted EXAFS data

  9. Electron microscopy and EXAFS studies on oxide-supported gold-silver nanoparticles prepared by flame spray pyrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Hannemann, Stefan [Institute of Chemical and Bioengineering, Swiss Federal Institute of Technology, ETH Hoenggerberg, CH-8093 Zurich (Switzerland); Grunwaldt, Jan-Dierk [Institute of Chemical and Bioengineering, Swiss Federal Institute of Technology, ETH Hoenggerberg, CH-8093 Zurich (Switzerland)]. E-mail: grunwaldt@chem.ethz.ch; Krumeich, Frank [Laboratory of Inorganic Chemistry, Swiss Federal Institute of Technology, ETH Hoenggerberg, CH-8093 Zurich (Switzerland); Kappen, Peter [Department of Physics, La Trobe University, Victoria 3086 (Australia); Baiker, Alfons [Institute of Chemical and Bioengineering, Swiss Federal Institute of Technology, ETH Hoenggerberg, CH-8093 Zurich (Switzerland)

    2006-09-15

    Gold and gold-silver nanoparticles prepared by flame spray pyrolysis (FSP) were characterized by electron microscopy, in situ X-ray absorption spectroscopy (XANES and EXAFS), X-ray diffraction (XRD) and their catalytic activity in CO oxidation. Within this one-step flame-synthesis procedure, precursor solutions of dimethyl gold(III) acetylacetonate and silver(I) benzoate together with the corresponding precursor of the silica, iron oxide or titania support, were sprayed and combusted. In order to prepare small metal particles, a low noble metal loading was required. A loading of 0.1-1 wt.% of Au and Ag resulted in 1-6 nm particles. The size of the noble metal particles increased with higher loadings of gold and particularly silver. Both scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDXS) and X-ray absorption spectroscopy (XAS) studies proved the formation of mixed Au-Ag particles. In case of 1% Au-1% Ag/SiO{sub 2}, TEM combined with electron spectroscopic imaging (ESI) using an imaging filter could be used in addition to prove the presence of silver and gold in the same noble metal particle. CO oxidation in the presence of hydrogen was chosen as a test reaction sensitive to small gold particles. Both the influence of the particle size and the alloying of gold and silver were reflected in the CO oxidation activity.

  10. Electron microscopy and EXAFS studies on oxide-supported gold-silver nanoparticles prepared by flame spray pyrolysis

    International Nuclear Information System (INIS)

    Hannemann, Stefan; Grunwaldt, Jan-Dierk; Krumeich, Frank; Kappen, Peter; Baiker, Alfons

    2006-01-01

    Gold and gold-silver nanoparticles prepared by flame spray pyrolysis (FSP) were characterized by electron microscopy, in situ X-ray absorption spectroscopy (XANES and EXAFS), X-ray diffraction (XRD) and their catalytic activity in CO oxidation. Within this one-step flame-synthesis procedure, precursor solutions of dimethyl gold(III) acetylacetonate and silver(I) benzoate together with the corresponding precursor of the silica, iron oxide or titania support, were sprayed and combusted. In order to prepare small metal particles, a low noble metal loading was required. A loading of 0.1-1 wt.% of Au and Ag resulted in 1-6 nm particles. The size of the noble metal particles increased with higher loadings of gold and particularly silver. Both scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDXS) and X-ray absorption spectroscopy (XAS) studies proved the formation of mixed Au-Ag particles. In case of 1% Au-1% Ag/SiO 2 , TEM combined with electron spectroscopic imaging (ESI) using an imaging filter could be used in addition to prove the presence of silver and gold in the same noble metal particle. CO oxidation in the presence of hydrogen was chosen as a test reaction sensitive to small gold particles. Both the influence of the particle size and the alloying of gold and silver were reflected in the CO oxidation activity

  11. Universal energy-dispersive EXAFS spectrometer based on SR beam of `Kurchatovskij Institute` and scientific program of investigations; Universal`nyj ehnergodispersionnyj EXAFS-spektrometr v Natsional`nom tsentre sinkhrotronnogo izlucheniya (`Kurchatovskij institut`) i nauchnaya programma issledovanij

    Energy Technology Data Exchange (ETDEWEB)

    Aksenov, V L; Ivanov, I N [Laboratory of Particle Physics, Joint Institute for Nuclear Research, Dubna (Russian Federation); Koval` chuk, M V [Institut Kristallografii, RAN, Moscow (Russian Federation); and others

    1997-12-31

    The scheme of the energy-dispersive EXAFS spectrometer is discussed. The spectrometer will be used for the solid state investigations on the Kurchatov Synchrotron Radiation Source KSRS. The main elements of the universal station are described, including the results of the positive-sensitive X-ray detector testing. The experimental investigations are presented which are supposed to be carried out with this EXAFS spectrometer. (author). 4 refs., 14 figs., 1 tab. Submitted to Poverkhnost`. Rentgenovskie, Sinkhrotronnye i Nejtronnye Issledovaniya.

  12. Iodine K-edge EXAFS analysis of iodide ion-cyclodextrin inclusion complexes in aqueous solution

    International Nuclear Information System (INIS)

    Kaneko, T; Ueda, M; Nagamatsu, S; Konishi, T; Fujikawa, T; Mizumaki, M

    2009-01-01

    We study the structure of inclusion complexes of α-, β-, γ-cyclodextrin with mono-iodide ion in aqueous solution by means of iodine K-edge EXAFS spectroscopy. The analysis is based on the assumption that two kinds of iodide ions exist in KI-cyclodextrin aqueous solution i.e. hydrated mono-iodide ions and one-one mono-iodide-cyclodextrin inclusion complexes. In KI-α-cyclodextrin system, iodine K-edge EXAFS analyse show that the average coordination number of the oxygen atoms in water molecules in the first hydration shell decreases as the fraction of included ions increases. This result suggests that dehydration process accompanies the formation of the inclusion complex. This is not found in the case of β-cyclodextrin, indicating that in this case the iodide ions are included together with the whole first hydration shell.

  13. EXAFS study influence of pH on microscopic structure of zinc

    International Nuclear Information System (INIS)

    Li Xianliang; Chongqing Entry-Exit Inspection and Quarantine Bureau, Chongqing; Pan Gang; Zhu Mengqiang; Chen Hao; Hu Tiandou; Wu Ziyu; Xie Yaning; Du Yonghua

    2004-01-01

    Microscopic local structures of Zn(II) were studied using extended X-ray absorption fine structure (EXAFS) spectroscopy under different pH conditions. When pH 2+ (aq) was coordinated with six water molecules and the average Zn-O distance was measured to be 2.08 Angstrom, which indicated that hydrated Zn 2+ (aq) ions were in octahedral geometry under acid conditions. Under alkaline conditions, Zn 2+ (aq) was coordinated with four water molecules and the average Zn-O distance was measured to be 1.96 Angstrom, which indicated that hydrated Zn 2+ (aq) ions were in tetrahedral geometry. EXAFS results provided detailed information on the form and microscopic structure of hydrated Zn(II) ions under different pH conditions, which were fundamental for understanding the reactivity of Zn(II) in solutions and at particle-water interfaces. (authors)

  14. Removal of Cu from aqueous solutions by synthetic hydroxyapatite: EXAFS investigation

    International Nuclear Information System (INIS)

    Corami, Alessia; D'Acapito, Francesco; Mignardi, Silvano; Ferrini, Vincenzo

    2008-01-01

    The sorption of aqueous Cu on synthetic hydroxyapatite has been investigated by means of the results of a combined structural simulation and extended X-ray absorption fine structure (EXAFS) analysis. The removal of Cu was studied in batch experiments at 25 ± 2 deg. C. The sorption of Cu follows Langmuir behaviour and was attributed to a two-step mechanism involving surface complexation and ion exchange with Ca resulting in the formation of a copper-containing hydroxyapatite. EXAFS results suggest that the heavy metal is present in the Cu 2+ form. The structural experimental and theoretical analysis shows that Cu is bond to about four O atoms at a distance of about 1.95 A. In all the studied cases the immobilization site of Cu is the same. The fixation of Cu occurs in the surface sites of hydroxyapatite whereas the sorption in the Ca sites in the inner part of the structure is unlikely

  15. A gas microstrip X-ray detector for soft energy fluorescence EXAFS

    CERN Document Server

    Smith, A D; Derbyshire, G E; Duxbury, D M; Lipp, J; Spill, E J; Stephenson, R

    2001-01-01

    Gas microstrip detectors have been previously developed by the particle physics community, where their robustness, compactness and high counting speed have been recognised. These features are particularly attractive to synchrotron radiation use. In this paper, we describe a gas microstrip detector employing multi-element readout and specifically developed for high count rate fluorescence EXAFS at soft X-ray energies below 4 keV.

  16. EXAFS and RDF studies of Ge27S53I20 glass

    International Nuclear Information System (INIS)

    Nasu, H.; Myoren, H.; Makida, S.; Imura, T.; Osaka, Y.

    1988-01-01

    Detailed X-ray diffraction measurements and extended X-ray absorption fine structure (EXAFS) have been applied to Ge 23 S 57 I 20 glass as a typical chalcohalide glass and to GeS 2 glass for comparison, in order to investigate the structure of Ge-S-I glass system. From the derived curves against atomic distance, the formation of Ge-I bonds is evidenced in the glass structure. (author) 4 refs., 2 figs., 1 tab

  17. Interaction between crystal lattice and mobile ions in copper selenides studied by EXAFS spectroscopy

    International Nuclear Information System (INIS)

    Asylgushina, G.N.; Bikkulova, N.N.; Titova, S.G.; Kochubey, D.I.

    2005-01-01

    Interaction between crystal lattice and mobile Cu ions has been studied in Cu 2- x Se in superionic and in normal state using EXAFS-spectroscopy. It has been found that the transition from normal to superionic state and change of mobile Cu ion concentration practically do not have an influence on local state of Cu atoms, but change of both these parameters is accompanied by a change of Se-sublattice state

  18. EXAFS study of the stability of amorphous TbFe thin films

    International Nuclear Information System (INIS)

    Samant, M.G.; Marinero, E.E.; Robinson, C.; Cargill, G.S.

    1989-01-01

    This paper discusses the measurement of the local atomic structure of Fe in Au doped Tb-Fe thin film alloys by the use of EXAFS. The as deposited sample shows structural features which are essentially identical to those of the undoped films. Au additions stabilizes the amorphous structure against recrystallization, however, the loss of magnetic anisotropy under thermal annealing is not reduced. This demonstrates that magnetic relaxation in these alloys does not involve crystallization of the amorphous structure

  19. Self-consistent EXAFS PDF Projection Method by Matched Correction of Fourier Filter Signal Distortion

    International Nuclear Information System (INIS)

    Lee, Jay Min; Yang, Dong-Seok

    2007-01-01

    Inverse problem solving computation was performed for solving PDF (pair distribution function) from simulated data EXAFS based on data FEFF. For a realistic comparison with experimental data, we chose a model of the first sub-shell Mn-0 pair showing the Jahn Teller distortion in crystalline LaMnO3. To restore the Fourier filtering signal distortion, involved in the first sub-shell information isolated from higher shell contents, relevant distortion matching function was computed initially from the proximity model, and iteratively from the prior-guess during consecutive regularization computation. Adaptive computation of EXAFS background correction is an issue of algorithm development, but our preliminary test was performed under the simulated background correction perfectly excluding the higher shell interference. In our numerical result, efficient convergence of iterative solution indicates a self-consistent tendency that a true PDF solution is convinced as a counterpart of genuine chi-data, provided that a background correction function is iteratively solved using an extended algorithm of MEPP (Matched EXAFS PDF Projection) under development

  20. EXAFS Study on LiFePO4 Powders Produced From Two Sol-Gel Routes

    Science.gov (United States)

    Negara, V. S. I.; Latif, C.; Wongtepa, W.; Pratapa, S.

    2018-04-01

    The local structure of LiFePO4 powders has been investigated using Fe K-edge Extended X-Ray Absorption Fine Structure (EXAFS) Spectroscopy data. The synthesis of LFP powders was carried out using two different sol-gel methods. The raw materials for Fe source were ironstone and commercial precursor of FeCl2·4H2O. Synthesis using natural materials produced two phases, namely LiFePO4 olivine and Li3Fe2(PO4)3 nasicon, whereas that using a commercial product produced a single phase of LiFePO4 olivine. The EXAFS data for both samples were collected at Synchrotron Light Research Institute (SLRI), Thailand. Fitting of the model on the experimental curve provided parameters that can be interpreted as the distance between Fe as the absorber and the nearest atoms on the LFP materials. The EXAFS data analysis has shown that synthesis of LFPs using different Fe sources gives slightly different nearest-neighbor distances, namely Fe-O of 0.21% -0.23%, Fe-P of 0.14% - 0.16%, Fe-Fe of 0.12% for both samples, respectively.

  1. The local structure of U(VI)-ferri-hydrite sorption complexes revisited: EXAFS spectroscopy and Monte-Carlo simulations

    International Nuclear Information System (INIS)

    Rossberg, A.; Ulrich, K.U.; Scheinost, A.C.

    2005-01-01

    Full text of publication follows: EXAFS analysis of actinyl sorption complexes is a complicated task due to the presence of overlapping shells, structural disorder and the presence of multiple scattering paths due to the specific actinyl structure. Hence often controversial interpretations arise from conventional shell fitting. A typical example is the proposed formation of ternary uranyl carbonato surface complexes on ferri-hydrite, where a peak at ∼2.4 Angstrom in the Fourier transform is explained by backscattering carbon atoms at 2.86-2.94 Angstrom. While such ternary carbonate complexes have been confirmed by complementary techniques like FTIR and electrophoretic mobility measurements, the EXAFS peak shows even up in those uranyl ferri-hydrite systems, where great care has been taken to keep the system carbonate-free, rendering an EXAFS fit with carbon meaningless. To overcome this common problem of EXAFS shell fitting, we developed a new analysis approach based on Monte-Carlo simulations coupled to theoretical EXAFS modeling using FEFF. Here, the position of the uranyl atom is first refined in relation to a given ferri-hydrite surface structure. In a second step, the whole complex structure is refined to allow for e.g. surface relaxation effects. Using this approach, a match to the experimental EXAFS spectra of U(VI) ferri-hydrite complexes without carbonate could be achieved. The local structure indicates a mononuclear bidentate (edge-sharing) surface complex, which was identified for the first time by EXAFS spectroscopy. Further fits were performed to elucidate the influence of carbonate and other anions on the structure of the surface complex. The results demonstrate the potential of the Monte-Carlo approach for determining the structure of actinyl surface complexes. (authors)

  2. Polarized XANES and EXAFS spectroscopic investigation into copper(II) complexes on vermiculite

    Science.gov (United States)

    Furnare, Luca J.; Vailionis, Arturas; Strawn, Daniel G.

    2005-11-01

    Interaction of heavy metals with clay minerals can dominate solid-solution reactions in soil, controlling the fate of the metals in the environment. In this study we used powdered and polarized extended X-ray absorption fine structure (EXAFS) spectroscopy and X-ray absorption near edge spectroscopy (XANES) to investigate Cu sorbed on Llano vermiculite and compare the results to reported Cu sorption mechanism on Wyoming (WY) smectite and reduced South African (SA) vermiculite. Analysis of the Cu K-edge spectra revealed that Cu sorbed on Llano vermiculite at high ionic strength ( I) has the greatest degree of covalent bond character, followed by Cu sorbed on montmorillonite at high I, and Cu sorbed on reduced SA vermiculite at high I. Cu sorbed on clay minerals at low I has the least covalent character. EXAFS data from Cu sorbed Ca- and K-equilibrated Llano vermiculites showed the presence of a second-shell Al, Si, or Mg backscatterer at 3.02 Å. This distance is consistent with Cu sorbing via a corner-sharing monodentate or bidentate bond. Polarized XANES and EXAFS results revealed that the angle between the Cu atom and the mineral sorption sites is 68° with respect to the [001] direction. From the bond angle and the persistence of the second-shell backscatterer when the interlayer is collapsed (K-equilibration), we conclude that Cu adsorption on the Llano vermiculite is not occurring in the interlayer but rather Cu is adsorbing onto the edges of the vermiculite. Results from this research provide evidence that Cu forms inner-sphere and outer-sphere complexes on clay minerals, and does not form the vast multinuclear surface precipitates that have been observed for Co, Zn, and Ni.

  3. EXAFS investigation of uranium(6) complexes formed at Acidithiobacillus ferro oxidans types

    International Nuclear Information System (INIS)

    Merroun, M.; Reich, T.; Hennig, Ch.; Selenska-Pobell, S.

    2002-01-01

    Mining activities have brought excessive amounts of uranium into the environment. In uranium deposits a number of acidophilic chemo-litho-autotrophic bacteria have been identified which are able to oxidize sulphide minerals, elemental sulphur, ferrous iron and also (in the presence of uranium mineral) U(IV). In particular, the interaction of one representative of the group Acidithiobacillus ferro oxidans (new designation of Thiobacillus ferro oxidans) with uranium has been investigated. Uranium(VI) complex formations at the surfaces of Acidithiobacillus ferro oxidans were studied using uranium L III -edge extended X-ray absorption fine structure (EXAFS) spectroscopy. In all samples uranium is co-ordinated by two axial oxygen atoms (O ax ) at a distance of 1.77-1.78 angstrom. The average distance between uranium and the equatorial oxygen atoms (O eq ) is 2.35 angstrom. The co-ordination number for O eq is 5-6. In comparison to the uranium crystal structure data, the U-O eq distance indicates a co-ordination number of the equatorial oxygen of 5. Within the experimental error, there are no differences in the U-O bond distances between samples from the three types of A. ferro oxidans investigated. The fit to the EXAFS data of samples measured as wet pastes gave the same results as for dried samples. No significant structural differences were observed for the uranium complexes formed by the eco-types of A. ferro oxidans. However, the EXAFS spectra do indicate a formation of uranium complexes which are different from those formed by Bacilli where the bond length of 2.28 angstrom indicates a co-ordination number of 4 for the equatorial oxygen atoms. (authors)

  4. A new cell for high temperature EXAFS measurements in molten rare earth fluorides

    International Nuclear Information System (INIS)

    Rollet, Anne-Laure; Bessada, Catherine; Auger, Yannick; Melin, Philippe; Gailhanou, Marc; Thiaudiere, Dominique

    2004-01-01

    A new cell with simple design has been developed for high temperature X-rays absorption measurements in both solid and molten lanthanide fluorides. Two plates of pyrolitic boron nitride are fixed hermetically together around the samples in order to avoid any evaporation and atmosphere interaction. EXAFS spectra of molten mixtures of LiF-LaF 3 measured at the La L III absorption edge are reported up to 900 deg C, and show the ability of this cell to keep the salt and to perform long time acquisition improving the signal to noise ratio

  5. Local structure and speciation of uranium in strontium orthosilicate: TRFS and EXAFS studies

    International Nuclear Information System (INIS)

    Gupta, Santosh K.; Thulasidas, S.K.; Natarajan, V.; Yadav, A.K.; Bhattacharya, D.

    2015-01-01

    TRFS is used to investigate the valence state and coordination behavior of uranium in strontium orthosilicate. From TRFS measurement it was observed that uranium exists as U(VI) in the form of UO 2 2+ in Sr 2 SiO 4 . Based on life time measurement and EXAFS studies it was inferred that uranyl is stabilized on both 9- and 10- coordinated strontium polyhedra. Majority of uranyl ion occupy relatively asymmetric site in strontium silicate most probably 9-coordinated Sr sites. (author)

  6. Extended X-ray absorption fine structure (EXAFS) studies of supported catalysts

    International Nuclear Information System (INIS)

    Joyner, R.W.

    1979-01-01

    Since the rebirth of interest in extended X-ray absorption fine structure there have been several studies of systems of catalytic interest. This note is a preliminary account of an investigation of supported platinum catalysts and NiO/Al 2 O 3 catalysts. Experiments were performed on pressed disc samples at the DESY synchrotron, Hamburg, using the EXAFS spectrometer. The synchrotron operated at 7 GeV energy with a circulating current of approximately 4 mA; spectrum accumulation time was typically 45 minutes. (author)

  7. An EXAFS spectrometer on beam line 10B at the Photon Factory

    International Nuclear Information System (INIS)

    Oyanagi, Hiroyuki; Matsushita, Tadashi; Ito, Masahisa; Kuroda, Haruo.

    1984-03-01

    An EXAFS spectrometer installed on the beam line 10B at the Photon Factory is designed to cover the photon energy between 4 and 30 keV. Utilizing either a channel-cut or two flat silicon crystals as a monochromator, a beam intensity between 10 8 and 10 9 photons/sec is obtained at 9 keV with a resolution of 1 eV. The performance of the spectrometer, such as a signal-to-noise ratio or an energy resolution is demonstrated with examples of K edge absorption spectra of bromine, germanium, gallium arsenide, and zinc selenide. (author)

  8. EXAFS Study of Disorder in SrTiO3 Perovskite

    International Nuclear Information System (INIS)

    Kodre, Alojz; Arcon, Iztok; Gomilsek, Jana Padeznik; Zalar, Bostjan

    2007-01-01

    Ti K-edge EXAFS spectra of SrTiO3 at room temperature and at N2 boiling point are measured to detect the Ti ion displacement above and below the antiferrodistortive phase transition occurring at Tc = 105 K. The data yield a definite value of the displacement, only slightly dependent on the temperature. The sensitive dependence of the amplitude of Ti-O-Ti focusing paths on the scattering angle is used to infer the correlation of Ti displacements. A preference to alternating displacements is indicated

  9. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  10. STRUCTURAL STUDY OF BIS(2,6-BIS(PYRAZOL-3-YLPYRIDINENICKEL(II BY CALORIMETRY AND EXAFS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Kristian H Sugiyarto

    2010-06-01

    Full Text Available The main aim of this work is to reveal the complex formation of 2,6-bis(pyrazol-3-ylpyridine, bpp, with nickel(II perchlorate in DMF by calorimetric stepwise complex formation and then followed by EXAFS spectrometry. It was found that the complex formation follows two stepwise pathways namely the formation of mono pyrazolyl-pyridine, [Ni(DMF3 bpp]2+, and bis pyrazolyl-pyridine, [Ni(bpp2]2+;  the formation constants being  log β1 = 6.57, and log β2 = 5.02, and the total value of log β  = 11.58. The final formation of six-coordinated compound was confirmed by EXAFS analysis with the mean Ni-Nbpp bond length of 2.0646(0.0014 Å.   Keywords: nickel(II, bpp, EXAFS

  11. Characterization of isolated Ag cations in homoionic Ag-Y zeolites: A combined anomalous XRPD and EXAFS study

    International Nuclear Information System (INIS)

    Lamberti, C.; Prestipino, C.; Bordiga, S.; Fitch, A.N.; Marra, G.L.

    2003-01-01

    In this contribution we report a structural characterization of a homoionic Ag-Y zeolite (Si/Al=2.63) on both short (EXAFS) and long range (XRD) scales. Our study shows that the zeolite is a near-100% exchanged silver faujasite, showing almost isolated Ag + counterions (EXAFS estimates that clustered species represent less than 2% of the whole silver). Synchrotron radiation XRPD measurements (ESRF, BM16), performed at the Ag-K edge (λ=0.486103(2) A), just before (λ=0.486093(2) A) and far away (λ=0.491153(2) A), allowed us to locate the near totality of the expected Ag + counterions: 51.9(4) out of 52.9 per unit cell, located in five different sites. The output of the Rietveld refinement has been used successfully to simulate the Ag-K edge EXAFS spectra (ESRF, BM29)

  12. Calcium EXAFS establishes the Mn-Ca cluster in the oxygen-evolving complex of Photosystem II

    Energy Technology Data Exchange (ETDEWEB)

    Cinco, Roehl M.; McFarlane Holman, Karen L.; Robblee, John H.; Yano, Junko; Pizarro, Shelly A.; Bellacchio, Emanuele; Sauer, Kenneth; Yachandra, Vittal K.

    2002-08-02

    The proximity of Ca to the Mn cluster of the photosynthetic water-oxidation complex is demonstrated by X-ray absorption spectroscopy. We have collected EXAFS data at the Ca K-edge using active PS II membrane samples that contain approximately 2 Ca per 4 Mn. These samples are much less perturbed than previously investigated Sr-substituted samples, which were prepared subsequent to Ca depletion. The new Ca EXAFS clearly shows backscattering from Mn at 3.4 angstroms, a distance that agrees with that surmised from previously recorded Mn EXAFS. This result is also consistent with earlier related experiments at the Sr K-edge, using samples that contained functional Sr, that show Mn is {approx}; 3.5 angstroms distant from Sr. The totality of the evidence clearly advances the notion that the catalytic center of oxygen evolution is a Mn-Ca heteronuclear cluster.

  13. Extended x-ray absorption fine structure (EXAFS): a novel probe for local structure of glassy solids

    International Nuclear Information System (INIS)

    Wong, J.

    1979-01-01

    The extended x-ray absorption fine structure (EXAFS) is the oscillation in the absorption coefficient extending a few hundred eVs on the high energy side of an x-ray absorption edge. This mode of spectroscopy has recently been realized to be a powerful tool in probing the local atomic structure of all states of matter, particularly with the advent of intense synchrotron radiation. More importantly is the unique ability of EXAFS to probe the structure and dynamics around individual atomic species in a multi-atomic system. In this paper, the physical processes associated with the EXAFS phenomenon will be discussed. Experimental results obtained at the Stanford Synchrotron Radiation Laboratory on some oxide and metallic glasses will be presented. The local structure in these materials are elucidated using a Fourier transform technique

  14. Controlled Oxygen Chemisorption on an Alumina Supported Rhodium Catalyst. The Formation of a New Metal-Metal Oxide Interface Determined with EXAFS.

    NARCIS (Netherlands)

    Koningsberger, D.C.; Martens, J.H.A.; Prins, R.

    1989-01-01

    An alumina-supported rhodium catalyst has been studied with EXAFS. After reduction and evacuation, oxygen was admitted at 100 and 300 K. EXAFS spectra of the catalyst after oxygen admission at 100 K indicated the beginning of oxidation. At 300 K only a small part of the rhodium particles remained

  15. Multiple Scattering Analysis of Cu - K EXAFS in Bi2Sr1.5 Cu2O8+δ

    International Nuclear Information System (INIS)

    Roehler, J.; Cruesemann, R.

    1995-01-01

    We have analyzed the Cu K-EXAFS of Bi 2 Sr 1.5 Ca 1.5 Cu 2 O 8+δ using a full multiple scattering analysis in a cluster with diameter d∼ 7.6 A. The layered structure has numerous quasi one-dimensional structural elements which give rise to significant multiple scattering contributions in the EXAFS. We confirm the Sr/Ca ratio of the sample is 1:1, and one Ca atom is located close to a nominal Sr-site. At 40 K the dimpling angle in the CuO 2 -plane is found to be ≤ 3.5 . (author)

  16. EXAFS measurements under high pressure conditions using a combination of a diamond anvil cell and synchrotron radiation

    International Nuclear Information System (INIS)

    Sueno, Shigeho; Nakai, Izumi; Imafuku, Masayuki; Morikawa, Hideki; Kimata, Mitsuyoshi; Ohsumi, Kazumasa; Nomura, Masaharu; Shimomura, Osamu.

    1986-01-01

    EXAFS spectra for Fe, Co, Ni K-edges were successfully measured under high pressure conditions using a combination of a set of normal 1/8 carat diamond anvils, synchrotron radiation and a scintillation counter. A newly developed motor controlled goniometer stage was used for adjusting the position of a miniature diamond anvil cell. On the measurement of Cr and Mn spectra, specially designed thinner diamond anvil was necessary. EXAFS analysis of bis(dimethylglyoximato)nickel(II) at pressures from 1 atm to 5.6 GPa was made. (author)

  17. EXAFS and XANES analysis of plutonium and cerium edges from titanate ceramics for fissile materials disposal

    International Nuclear Information System (INIS)

    Fortner, J. A.; Kropf, A. J.; Bakel, A. J.; Hash, M. C.; Aase, S. B.; Buck, E. C.; Chamerlain, D. B.

    1999-01-01

    We report x-ray absorption near edge structure (XANES) and extended x-ray absorption fine structure (EXAFS) spectra from the plutonium L III edge and XANES from the cerium L II edge in prototype titanate ceramic hosts. The titanate ceramics studied are based upon the hafnium-pyrochlore and zirconolite mineral structures and will serve as an immobilization host for surplus fissile materials, containing as much as 10 weight % fissile plutonium and 20 weight % (natural or depleted) uranium. Three ceramic formulations were studied: one employed cerium as a ''surrogate'' element, replacing both plutonium and uranium in the ceramic matrix, another formulation contained plutonium in a ''baseline'' ceramic formulation, and a third contained plutonium in a formulation representing a high-impurity plutonium stream. The cerium XANES from the surrogate ceramic clearly indicates a mixed III-IV oxidation state for the cerium. In contrast, XANES analysis of the two plutonium-bearing ceramics shows that the plutonium is present almost entirely as Pu(IV) and occupies the calcium site in the zirconolite and pyrochlore phases. The plutonium EXAFS real-space structure shows a strong second-shell peak, clearly distinct from that of PuO 2 , with remarkably little difference in the plutonium crystal chemistry indicated between the baseline and high-impurity formulations

  18. In-situ EXAFS study on the thermal decomposition of TiH2

    International Nuclear Information System (INIS)

    Zhou Yingli; Wu Min; An Pengfei; Zheng Lirong; Chu Shengqi; Zhang Jing; Hu Tiandou

    2014-01-01

    Thermal decomposition behaviors of TiH 2 powder under a flowing helium atmosphere and in a low vacuum condition have been studied using an in situ EXAFS technique. By an EXAFS analysis containing the multiple scattering paths including H atoms, the changes of the hydrogen stoichiometric ratio and the phase transformation sequence are obtained. The results demonstrate that the initial decomposition temperature is dependent on experimental conditions, which occurs, respectively, at about 300 and 400 °C in a low vacuum condition and under a flowing helium atmosphere. During the decomposition process of TiH 2 in a low vacuum condition, the sample experiences a phase change process: δ(TiH 2 ) → δ (TiH x ) → δ(TiH x )+ β(TiH x ) → δ(TiH x )+ β(TiH x ) + α(Ti) → β(TiH x ) + α(Ti) → α(Ti) + β(Ti). This study offers a way to detect the structural information of hydrogen. A detailed discussion about the decomposition process of TiH 2 is given in this paper. (authors)

  19. Characterization of U(VI)-carbonato ternary complexes on hematite: EXAFS and electrophoretic mobility measurements

    Science.gov (United States)

    Bargar, John R.; Reitmeyer, Rebecca; Lenhart, John J.; Davis, James A.

    2000-01-01

    We have measured U(VI) adsorption on hematite using EXAFS spectroscopy and electrophoresis under conditions relevant to surface waters and aquifers (0.01 to 10 μM dissolved uranium concentrations, in equilibrium with air, pH 4.5 to 8.5). Both techniques suggest the existence of anionic U(VI)-carbonato ternary complexes. Fits to EXAFS spectra indicate that U(VI) is simultaneously coordinated to surface FeO6 octahedra and carbonate (or bicarbonate) ligands in bidentate fashions, leading to the conclusion that the ternary complexes have an inner-sphere metal bridging (hematite-U(VI)-carbonato) structure. Greater than or equal to 50% of adsorbed U(VI) was comprised of monomeric hematite-U(VI)-carbonato ternary complexes, even at pH 4.5. Multimeric U(VI) species were observed at pH ≥ 6.5 and aqueous U(VI) concentrations approximately an order of magnitude more dilute than the solubility of crystalline β-UO2(OH)2. Based on structural constraints, these complexes were interpreted as dimeric hematite-U(VI)-carbonato ternary complexes. These results suggest that Fe-oxide-U(VI)-carbonato complexes are likely to be important transport-limiting species in oxic aquifers throughout a wide range of pH values.

  20. An EXAFS study of the structure of Co-Mo hydrodesulfurization catalysts

    International Nuclear Information System (INIS)

    Clausen, B.S.; Topsoe, H.; Candia, R.; Villadsen, J.; Lengeler, B.

    1981-05-01

    By analysing the extended X-ray absorption fine structure (EXAFS) of the Mo absorption edge, structural information about both calcined and sulfided Mo/Al 2 O 3 and Co-Mo/Al 2 O 3 catalysts has been obtained. The calcined catalysts show only one strong backscatterer peak in the radial distribution function, which indicates that molybdenum is present in a highly disordered structure. For the Co-Mo/Al 2 O 3 catalyst the presence of cobalt seems to have some effect on the immediate surroundings of molybdenum. Upon sulfiding the catalysts, an ordering of the molybdenum-containing phase takes place as evidenced by the observation of a contribution from the second coordination shell. From a comparison with EXAFS data obtained on well-crystallized MoS 2 it is concluded that the molybdenum atoms in the catalysts are present in MoS 2 -like structures. Furthermore, from a comparison of the amplitude of the Mo-backscatterer peak it is found that these MoS 2 -like structures are ordered in very small domains. (orig.)

  1. EXAFS: Possibilities, advantages and limitations for the investigation of local order in metallic glasses

    International Nuclear Information System (INIS)

    Haensel, R.; Rabe, P.; Tolkiehn, G.; Werner, A.

    1980-06-01

    Throughout this book many examples for the close relationship between the macroscopic properties and the local structure of liquid and amorphous metals and alloys are given. Complementing the conventional X-ray, electron and neutron scattering techniques the analysis of the Extended X-ray Absorption Fine Structure (EXAFS) has been developed to a reliable method for structural analysis. Although the phenomenon is known since the thirties of the century, its application for the determination of local geometrical parameters has only been introduced about ten years ago. The development of the method has been greatly stimulated by extensive theoretical work, e.g. more refined calculations of complex scattering amplitudes and by the availability of synchrotron radiation as an intense X-ray continuum source. Two aspects are discussed in this paper: i) the basic principles of EXAFS and the usual data evaluation techniques demonstrated for crystalline Fe; ii) Applications on amorphous systems, the modifications of the data evaluation due to nonsymmetric pair distributions and the comparison with other methods for structure determination. (orig.)

  2. Silver and copper nanoclusters in the lustre decoration of Italian Renaissance pottery: an EXAFS study

    Science.gov (United States)

    Padovani, S.; Borgia, I.; Brunetti, B.; Sgamellotti, A.; Giulivi, A.; D'Acapito, F.; Mazzoldi, P.; Sada, C.; Battaglin, G.

    Lustre is one of the most important decorative techniques of the Medieval and Renaissance pottery of the Mediterranean basin, capable of producing brilliant metallic reflections and iridescence. Following the recent finding that the colour of lustre decorations is mainly determined by copper and silver nanoclusters dispersed in the glaze layer, the local environment of copper and silver atoms has been studied by extended X-ray absorption fine structure (EXAFS) spectroscopy on original samples of gold and red lustre. It has been found that, in gold lustre, whose colour is attributed mainly to the silver nanocluster dispersion, silver is only partially present in the metallic form and copper is almost completely oxidised. In the red lustre, whose colour is attributed mainly to the copper nanocluster dispersion, only a fraction of copper is present in the metallic form. EXAFS measurements on red lustre, carried out in the total electron yield mode to probe only the first 150 nm of the glaze layer, indicated that in some cases lustre nanoclusters may be confined in a very thin layer close to the surface.

  3. Sorption Speciation of Lanthanides/Actinides on Minerals by TRLFS, EXAFS and DFT Studies: A Review

    Directory of Open Access Journals (Sweden)

    Xiaoli Tan

    2010-11-01

    Full Text Available Lanthanides/actinides sorption speciation on minerals and oxides by means of time resolved laser fluorescence spectroscopy (TRLFS, extended X-ray absorption fine structure spectroscopy (EXAFS and density functional theory (DFT is reviewed in the field of nuclear disposal safety research. The theoretical aspects of the methods are concisely presented. Examples of recent research results of lanthanide/actinide speciation and local atomic structures using TRLFS, EXAFS and DFT are discussed. The interaction of lanthanides/actinides with oxides and minerals as well as their uptake are also of common interest in radionuclide chemistry. Especially the sorption and inclusion of radionuclides into several minerals lead to an improvement in knowledge of minor components in solids. In the solid-liquid interface, the speciation and local atomic structures of Eu(III, Cm(III, U(VI, and Np(IV/VI in several natural and synthetic minerals and oxides are also reviewed and discussed. The review is important to understand the physicochemical behavior of lanthanides/actinides at a molecular level in the natural environment.

  4. EXAFS and XPS Study of Rutile-Type Difluorides of First-Row Transition Metals

    International Nuclear Information System (INIS)

    Murai, Kei-ichiro; Suzuki, Yohei; Moriga, Toshihiro; Yoshiasa, Akira

    2007-01-01

    Although most rutile-type difluorides (MnF2, CoF2 and NiF2) have a positive thermal expansion coefficient, FeF2 has a negative thermal expansion (NTE) along the c-axis in the high temperature region. In this study, we give an explanation of that behavior with Extended X-ray Absorption Fine Structure (EXAFS) and X-ray Photoelectron Spectroscopy (XPS) techniques. From EXAFS results, it has become apparent that the length of the share-edge (Fe-Fe) of FeF6 octahedra increased with the rise of temperature in the high temperature region. We have revealed that the force constant between nearest neighbor atoms (Fe-F) was much larger than that between second-nearest neighbor atoms (Fe-Fe) in FeF2. In XPS measurements, it was discovered that the peak of F 1s of FeF2 was located at the lowest binding energy position as compared to that of other difluorides. This means that the charge density around the F atom in FeF2 was higher than that in other difluorides. It follows from this that the share-edge repulsive force in FeF2 is larger than that in other difluorides. On account of the large repulsive force and the large force constant between nearest neighbor atoms, Fe atoms are attracted to share-edge with the rise of temperature

  5. DFT and EXAFS, mutually enhancing tools for structure elucidation of Tc complexes

    International Nuclear Information System (INIS)

    Breynaert, E.; Bruggeman, C.; Maes, A.

    2005-01-01

    Full text of publication follows: The redox-sensitive fission product technetium-99 (Tc) is of great interest in nuclear waste disposal studies because of its potential for contaminating the geosphere due to its very long half-life (2.13 x 10 5 year) and high mobility under oxidising conditions, where technetium forms pertechnetate (TcO 4 - ). Under suitable reducing conditions, e.g. in the presence of an iron(II) containing solid phase which can act as an electron donor, the solubility can be limited by the reduction of pertechnetate followed by the formation of a surface precipitate [1]. However, by association with mobile humic substances (HS) or other associating/complexing species, the solubility of reduced Tc species may be drastically enhanced [2]. The elucidation of the identity and geometrical structure of the species causing this enhanced solubility often remains a difficult issue. Extended X-Ray Absorption Fluorescence Spectroscopy/ X-Ray Absorption Near Edge Spectroscopy (EXAFS/XANES) analysis can be very helpful to determine the molecular surroundings of reduced Tc organic complexes of Tc(IV) colloid-HS-associations. The interpretation of the EXAFS spectra is however not a straightforward process due to the possibly strong influence of multiple scattering paths on the spectra. Contrary to single scattering analysis which can be easily performed on the experimental EXAFS spectra, multiple scattering analysis can only be done, based on good approximations of the possible geometrical structures of the species under consideration. It has been shown that the Density Functional Theory (DFT) can be used to perform geometry optimizations of technetium species and therefore can be utilized to predict the structure of technetium complexes [3]. The success and computational effort needed for such structure predictions are however highly dependant on the quality of the initial structure from which the geometry optimization is started. Single scattering analysis of

  6. REDOX state analysis of platinoid elements in simulated high-level radioactive waste glass by synchrotron radiation based EXAFS

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Yoshihiro, E-mail: okamoto.yoshihiro@jaea.go.jp [Condensed Matter Chemistry Group, Quantum Beam Science Center, Japan Atomic Energy Agency, Shirakata 2-4, Tokai-mura, Ibaraki 319-1195 (Japan); Shiwaku, Hideaki [Quantum Beam Science Center, Japan Atomic Energy Agency, Kouto 1-1-1, Sayo-cho, Hyogo 679-5143 (Japan); Nakada, Masami [Nuclear Engineering Science Center, Japan Atomic Energy Agency, Shirakata 2-4, Tokai-mura, Ibaraki 319-1195 (Japan); Komamine, Satoshi; Ochi, Eiji [Japan Nuclear Fuel Limited, 4-108 Aza Okitsuke, Oaza Obuchi, Rokkasho-mura, Aomori 030-3212 (Japan); Akabori, Mitsuo [Nuclear Engineering Science Center, Japan Atomic Energy Agency, Shirakata 2-4, Tokai-mura, Ibaraki 319-1195 (Japan)

    2016-04-01

    Extended X-ray Absorption Fine Structure (EXAFS) analyses were performed to evaluate REDOX (REDuction and OXidation) state of platinoid elements in simulated high-level nuclear waste glass samples prepared under different conditions of temperature and atmosphere. At first, EXAFS functions were compared with those of standard materials such as RuO{sub 2}. Then structural parameters were obtained from a curve fitting analysis. In addition, a fitting analysis used a linear combination of the two standard EXAFS functions of a given elements metal and oxide was applied to determine ratio of metal/oxide in the simulated glass. The redox state of Ru was successfully evaluated from the linear combination fitting results of EXAFS functions. The ratio of metal increased at more reducing atmosphere and at higher temperatures. Chemical form of rhodium oxide in the simulated glass samples was RhO{sub 2} unlike expected Rh{sub 2}O{sub 3}. It can be estimated rhodium behaves according with ruthenium when the chemical form is oxide.

  7. Structure of Rhodium in an Ultradispersed Rhodium/Alumina Catalyst as Studied by EXAFS and Other Technique

    NARCIS (Netherlands)

    Koningsberger, D.C.; Blik, H.F.J. van 't; Zon, J.B.A.D. van; Huizinga, T.; Vis, J.C.; Prins, R.

    1985-01-01

    The structure of rhodium in an ultradispersed 0.57 wt % Rh/y-Al,O, catalyst before and after CO adsorption was studied with extended X-ray absorption fine structure (EXAFS), X-ray photoelectron spectroscopy (XPS), electron spin resonance (ESR), temperature programmed reduction (TPR), CO infrared

  8. Renal scan

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  9. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  10. Comparative EXAFS study of uranium(VI) and neptunium(V) sorption onto kaolinite

    International Nuclear Information System (INIS)

    Reich, T.; Amayri, S.; Reich, Ta.; Jermolajev, J.

    2005-01-01

    Full text of publication follows: We investigated the surface sorption process of U(VI) and Np(V) on kaolinite by extended X-ray absorption fine structure (EXAFS) spectroscopy in the 10 μM concentration range. Batch experiments with kaolinite in CO 2 -equilibrated systems showed that the adsorption edge of U(VI) occurs at pH 5.5, i.e., near the pH PZC of kaolinite. The adsorption edge of Np(V) occurs well above the pH PZC value at pH 8.5. This may indicate that the bonds between Np(V) and the surface functional groups of kaolinite are not as strong as in the case of U(VI). U(VI) and Np(V) have in common that the amount which is adsorbed decreases when the pH is increased beyond the absorption maximum. This behavior can be attributed to the formation of U(VI) and Np(V) carbonato complexes in the aqueous solutions. The aim of this comparative EXAFS study was to investigate the reason for the different affinities of U(VI) and Np(V) for kaolinite by measuring their local environments at the clay surface. Samples were prepared from 4 g/L kaolinite, 0.1 M NaClO 4 , pH 3.0 - 10.5, presence and absence of ambient CO 2 . The U L 3 - and Np L 2 -edge EXAFS spectra of the wet paste samples were measured at room temperature in fluorescence mode at the Rossendorf Beamline (ROBL) at the European Synchrotron Radiation Facility. The measured U-O and U-Al/Si distances indicate inner-sphere sorption of U(VI) on kaolinite. There was no evidence of uranium neighbors in the EXAFS spectra, suggesting that the adsorbed U(VI) complexes were predominantly monomeric. The average distance between uranium and its equatorial oxygen atoms, O eq , increased from 2.32 to 2.38 Angstrom in the presence of atmospheric CO 2 when the pH was increased from 5.0 to 8.5. In the CO 2 -free system, the U-O eq distance was independent from pH and equal to 2.32 Angstrom. The lengthening of the average U-O eq distance in the presence of carbonate (or bicarbonate) suggests the formation of ternary U

  11. The Mn site in Mn-doped GaAs nanowires: an EXAFS study

    International Nuclear Information System (INIS)

    D’Acapito, F; Rovezzi, M; Boscherini, F; Jabeen, F; Bais, G; Piccin, M; Rubini, S; Martelli, F

    2012-01-01

    We present an EXAFS study of the Mn atomic environment in Mn-doped GaAs nanowires. Mn doping has been obtained either via the diffusion of the Mn used as seed for the nanowire growth or by providing Mn during the growth of Au-induced wires. As a general finding, we observe that Mn forms chemical bonds with As but is not incorporated in a substitutional site. In Mn-induced GaAs wires, Mn is mostly found bonded to As in a rather disordered environment and with a stretched bond length, reminiscent of that exhibited by MnAs phases. In Au-seeded nanowires, along with stretched MnAs coordination, we have found the presence of Mn in a MnAu intermetallic compound. (paper)

  12. A study on the structures of hemoglobin of diabetic patients by EXAFS technique

    International Nuclear Information System (INIS)

    Wang Yinsong; Tan Mingguang; Zhang Guilin

    2001-01-01

    Hemoglobin was the carrier of oxygen in blood circulation. For the patients with diabetes mellitus the enhancement of glycidate hemoglobin in blood causes the decrease of oxygen transmission function. The local atomic structures of iron in hemoglobin were determined by EXAFS techniques. The relationship between diabetes mellitus and hemoglobin structures was observed. The blood samples were taken from normal people, slight and serious diabetic patients. The results show that the coordination number of iron atoms and Fe-O bond length were almost the same for the three samples. However, for the samples of serious diabetic patients the Fe-N bond length increases by about 0.002 nm, the possible reasons were the increase of deoxyhemoglobin contents in their blood

  13. EXAFS Phase Retrieval Solution Tracking for Complex Multi-Component System: Synthesized Topological Inverse Computation

    International Nuclear Information System (INIS)

    Lee, Jay Min; Yang, Dong-Seok; Bunker, Grant B

    2013-01-01

    Using the FEFF kernel A(k,r), we describe the inverse computation from χ(k)-data to g(r)-solution in terms of a singularity regularization method based on complete Bayesian statistics process. In this work, we topologically decompose the system-matched invariant projection operators into two distinct types, (A + AA + A) and (AA + AA + ), and achieved Synthesized Topological Inversion Computation (STIC), by employing a 12-operator-closed-loop emulator of the symplectic transformation. This leads to a numerically self-consistent solution as the optimal near-singular regularization parameters are sought, dramatically suppressing instability problems connected with finite precision arithmetic in ill-posed systems. By statistically correlating a pair of measured data, it was feasible to compute an optimal EXAFS phase retrieval solution expressed in terms of the complex-valued χ(k), and this approach was successfully used to determine the optimal g(r) for a complex multi-component system.

  14. Characterization of mercury based Indian herbomineral drug by radioisotope induced EDXRF and synchrotron based EXAFS

    International Nuclear Information System (INIS)

    Joseph, Daisy; Saxena, A.; Joseph, Rajeeta; Rajput, P.; Nayak, C.; Bhattacharya, D.; Jha, S.N.; Natrajan, V.

    2014-01-01

    An Indian herbomineral drug was characterized for its trace elements by radioisotope induced EDXRF. The drug contains minerals like mercury, sulfur and arsenic disulfide, along with herbs such as dhaturra, bhrami, vacha etc. All the above ingredients were processed together in a step wise manner (6 steps). Hence the motive was to expect some change in the drug molecule at every step of processing it. The 6 samples are the samples collected at every step of drug preparation. These 6 samples which are collected as intermediatary samples would be then evaluated for its role in various neuropsychological (psychosis, depression etc) disorders in experimental animals such as rats/mice. Hence it was required to find the elements/trace elements composition, details of chemical components present in the drug samples. It was seen that using EDXRF it was possible to determine As and Hg. The EXAFS results also showed the presence of As in their sulphide form. (author)

  15. High pressure and high temperature EXAFS and diffraction study of AgI

    International Nuclear Information System (INIS)

    Yoshiasa, Akira; Arima, Hiroshi; Fukui, Hiroshi; Okube, Maki; Katayama, Yoshinori; Ohtaka, Osamu

    2009-01-01

    We have determined the precise P-T phase diagram of AgI by in-situ high-pressure high-temperature synchrotron experiments. X-ray diffraction and XAFS measurements were performed up to 6.0 GPa and 1100 K using a multi-anvil high-pressure device and synchrotron radiation from SPring-8. In the disordered rock-salt phase, Ag ions occupy both octahedral and tetrahedral sites and twenty percent of Ag ions occupy the tetrahedral site as a maximum value at 2 GPa. From the viewpoint of the local structure analyses, some sudden changes are recognized near broad phase transition point. Analysis of EXAFS Debye-Waller factor is useful because the force constant can be decided directly even at high pressure and high temperature. Pressure influences greatly the effective potential and anharmonicity decreases with increasing pressure. (author)

  16. Combined mineralogical and EXAFS characterization of polluted sediments for the definition of technological variables and constraints

    Science.gov (United States)

    Brigatti, M. F.; Elmi, C.; Laurora, A.; Malferrari, D.; Medici, L.

    2009-04-01

    An extremely severe aspect, both from environmental and economic viewpoint, is the management of polluted sediments removed from drainage and irrigation canals. Canals, in order to retain their functionality over the time, need to have their beds, periodically cleaned from sediments there accumulating. The management of removed sediments is extremely demanding, also from an economical perspective, if these latter needs to be treated as dangerous waste materials, as stated in numerous international standards. Furthermore the disposal of such a large amount of material may introduce a significant environmental impact as well. An appealing alternative is the recovery or reuse of these materials, for example in brick and tile industry, after obviously the application of appropriate techniques and protocols that could render these latter no longer a threat for human health. The assessment of the effective potential danger for human health and ecosystem of sediments before and after treatment obviously requires both a careful chemical and mineralogical characterization and, even if not always considered in the international standards, the definition of the coordination shell of heavy metals dangerous for human health, as a function of their oxidation state and coordination (e.g. Cr and Pb), and introducing technological constraints or affecting the features of the end products. Fe is a good representative for this second category, as the features of the end product, such as color, strongly depend not only from Fe concentration but also from its oxidation state, speciation and coordination. This work will first of all provide mineralogical characterization of sediments from various sampling points of irrigation and drainage canals of Po river region in the north-eastern of Italy. Samples were investigated with various approaches including X-ray powder diffraction under non-ambient conditions, thermal analysis and EXAFS spectroscopy. Obtained results, and in particular

  17. Colloidal diatomite, radionickel, and humic substance interaction: a combined batch, XPS, and EXAFS investigation.

    Science.gov (United States)

    Sheng, Guodong; Shen, Runpu; Dong, Huaping; Li, Yimin

    2013-06-01

    This work determined the influence of humic acid (HA) and fulvic acid (FA) on the interaction mechanism and microstructure of Ni(II) onto diatomite by using batch experiments, X-ray photoelectron spectroscopy (XPS), and extended X-ray absorption fine structure (EXAFS) methods. Macroscopic and spectroscopic experiments have been combined to see the evolution of the interaction mechanism and microstructure of Ni(II) in the presence of HA/FA as compared with that in the absence of HA/FA. The results indicated that the interaction of Ni(II) with diatomite presents the expected solution pH edge at 7.0, which is modified by addition of HA/FA. In the presence of HA/FA, the interaction of Ni(II) with diatomite increased below solution pH 7.0, while Ni(II) interaction decreased above solution pH 7.0. XPS analysis suggested that the enrichment of Ni(II) onto diatomite may be due to the formation of (≡SO)2Ni. EXAFS results showed that binary surface complexes and ternary surface complexes of Ni(II) can be simultaneously formed in the presence of HA/FA, whereas only binary surface complexes of Ni(II) are formed in the absence of HA/FA, which contribute to the enhanced Ni(II) uptake at low pH values. The results observed in this work are important for the evaluation of Ni(II) and related radionuclide physicochemical behavior in the natural soil and water environment.

  18. Cooperative scans

    NARCIS (Netherlands)

    M. Zukowski (Marcin); P.A. Boncz (Peter); M.L. Kersten (Martin)

    2004-01-01

    textabstractData mining, information retrieval and other application areas exhibit a query load with multiple concurrent queries touching a large fraction of a relation. This leads to individual query plans based on a table scan or large index scan. The implementation of this access path in most

  19. Limitations on the extent of off-center displacements in TbMnO3 from EXAFS measurements

    International Nuclear Information System (INIS)

    Bridges, F.; Downs, C.; O'Brien, T.; Jeong, Il-K; Kimura, T.

    2007-01-01

    We present extended x-ray-absorption fine structure (EXAFS) data at the Mn K and Tb L 3 edges that provide upper limits on the possible displacements of any atoms in TbMnO 3 . The displacements must be less than 0.005-0.01 A for all atoms, which eliminates the possibility of moderate distortions (0.02 A) with a small c-axis component, but for which the displacements in the ab plane average to zero. Assuming the polarization arises from a displacement of the O2 atoms along the c axis, the measured polarization then leads to an O2 displacement that is at least 6x10 -4 A, well below our experimental limit. Thus, a combination of the EXAFS and the measured electrical polarization indicate that the atomic displacements likely lie in the range 6x10 -4 -5x10 -3 A

  20. Local atomic structure of Zr-Cu and Zr-Cu-Al amorphous alloys investigated by EXAFS method

    International Nuclear Information System (INIS)

    Antonowicz, J.; Pietnoczka, A.; Zalewski, W.; Bacewicz, R.; Stoica, M.; Georgarakis, K.; Yavari, A.R.

    2011-01-01

    Research highlights: → Coordination number, interatomic distances and mean square atomic displacement in Zr-Cu and Zr-Cu-Al glasses. → Icosahedral symmetry in local atomic structure. → Deviation from random mixing behavior resulting from Al addition. - Abstract: We report on extended X-ray absorption fine structure (EXAFS) study of rapidly quenched Zr-Cu and Zr-Cu-Al glassy alloys. The local atomic order around Zr and Cu atoms was investigated. From the EXAFS data fitting the values of coordination number, interatomic distances and mean square atomic displacement were obtained for wide range of compositions. It was found that icosahedral symmetry rather than that of corresponding crystalline analogs dominates in the local atomic structure of Zr-Cu and Zr-Cu-Al amorphous alloys. Judging from bonding preferences we conclude that addition of Al as an alloying element results in considerable deviation from random mixing behavior observed in binary Zr-Cu alloys.

  1. Relationship between the adsorption species of cesium and radiocesium interception potential in soils and minerals: an EXAFS study

    International Nuclear Information System (INIS)

    Fan, Qiaohui; Yamaguchi, Noriko; Tanaka, Masato; Tsukada, Hirofumi; Takahashi, Yoshio

    2014-01-01

    This study examined the radiocesium (RCs) interception potential (RIP), cation exchange capacity (CEC), total organic carbon (TOC) content, and adsorption species in soils and minerals by using extended X-ray absorption fine structure (EXAFS) spectroscopy. The RIP related to Cs + adsorption by frayed-edge site (FES) has often been used to measure the mobility and bioavailability of RCs in the environment. This study found that the presence of organic matter (OM) can reduce RIP to a certain extent. The adsorption amount (=Q T ) in soil was obviously correlated to RIP at a small [Cs + ] region, whereas a linear relationship between Q T and CEC was observed at a large [Cs + ] region. Both the inner-sphere (IS) and outer-sphere (OS) complexes of Cs + were observed through EXAFS at a molecular scale. The linear correlation between log (RIP/CEC) and the ratio of the coordination number (CN) of IS (=CN IS ) and OS (=CN OS ) complexes noted as CN IS /(CN IS + CN OS ) suggested that the ratio of CN is very sensitive to Cs + adsorption species with variable RIP and CEC. The adsorption species of Cs + in soil was mainly dependent on the clay mineral content of soil. RIP was affected not only by FES but also by other strong adsorption sites, such as the interlayers and cavities identified as the IS complex in EXAFS analysis. Findings indicated that the EXAFS approach is a powerful and efficient tool to explore the behavior of Cs + in a given environment. - Highlights: • The relationship of Cs + species on soils and minerals and RIP was firstly clarified in this study. • Coordination number of Cs + was very sensitive to Cs + adsorption species with variable RIP and CEC. • This finding can be used as a basis for understanding of Cs + behavior in nature

  2. X-ray photoemission spectroscopy (XPS) and extended x-ray absorption fine structure (EXAFS) studies of silicate based glasses

    International Nuclear Information System (INIS)

    Karim, D.; Lam, D.J.

    1979-01-01

    The application of the x-ray photoemission spectroscopy (XPS) technique to study the electronic structure and bonding of heavy metal oxides in alkali- and alkali-earth-silicate glasses had been demonstrated. The bonding characteristics of the iron oxide and uranium oxide in sodium silicate glasses were deduced from the changes in the oxygen 1s levels and the heavy metal core levels. It is reasonable to expect that the effect of leaching on the heavy metal ions can be monitored using the appropriate core levels of these ions. To study the effect of leaching on the glass forming network, the valence band structure of the bridging and nonbridging oxygens in sodium silicate glasses were investigated. The measurement of extended x-ray absorption fine-structure (EXAFS) is a relatively new analytical technique for obtaining short range (<5 A) structural information around atoms of a selected species in both solid and fluid systems. Experiments have recently begun to establish the feasibility of using EXAFS to study the bonding of actinides in silicate glasses. Because of the ability of EXAFS to yield specific structural data even in complex multicomponent systems, it could prove to be an invaluable tool in understanding glass structure

  3. Structure of bimetallic clusters. Extended x-ray absorption fine structure (EXAFS) studies of Rh--Cu clusters

    International Nuclear Information System (INIS)

    Meitzner, G.; Via, G.H.; Lytle, F.W.; Sinfelt, J.H.

    1983-01-01

    An investigation of the structure of the bimetallic clusters present in rhodium--copper catalysts was conducted with the use of extended x-ray absorption fine structure (EXAFS) measurements. Two catalysts were studied, both employing silica as a support for the clusters and both containing 1 wt. % rhodium. In one catalyst the Cu:Rh atomic ratio was 1:2 and in the other 1:1. Studies were made of the EXAFS associated with the K absorption edges of the rhodium and copper. The results of the EXAFS studies indicate that copper concentrates at the surface of the rhodium--copper clusters. In this regard the results are similar to our earlier reported results on ruthenium--copper clusters. However, the extent of surface segregation of the copper appears to be less pronounced for rhodium--copper clusters. This result is reasonable on the basis that rhodium and copper, unlike ruthenium and copper, exhibit at least some miscibility in the bulk

  4. EXAFS as a tool for investigation of the local environment of Ge atoms in buried low-dimensional structures

    International Nuclear Information System (INIS)

    Demchenko, I.N.; Lawniczak-Jablonska, K.; Liliental-Weber, Z.; Zakharov, D.N.; Zhuravlev, K.S.

    2005-01-01

    In spite of large number of articles dedicated to the investigation of GeSi islands, a lot of problems concerning growth mechanism and island composition, as well as elastic strains inside the QDs, are still unsolved. To solve such problems, the GeSi low dimensional structures were studied by Extended X-Ray Absorption Fine Structure (EXAFS). The aim of this investigation was to get knowledge about the local structure around Ge atoms inside formed quantum dots. The paper presents a series of measurements performed for a single Ge layer buried in the silicon matrix at A1 station at the HASYLAB/DESY (Germany) with the angle of 45 o between the incident beam and sample surface. The fluorescence, total electron yield and the transmission modes of detection were used. To confirm the EXAFS analysis conclusion more measurements were performed using transmission electron microscopy (TEM). The low temperature samples with 8-20 ML of Ge were investigated by cross-section and plan-view TEM. The reported results of TEM studies of the local structure of germanium quantum dots (QDs) in Si/Ge/Si '' sandwich '' structures are in good correlation with EXAFS conclusion

  5. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  6. EXAFS and XRD studies of nanocrystalline cerium oxide: the effect of preparation method on the microstructure

    International Nuclear Information System (INIS)

    Savin, S.L.P.; Chadwick, A.V.; Smith, M.E.; O'Dell, L.A.

    2007-01-01

    There is considerable interest in nanocrystalline materials due to their unusual properties, such as enhanced ionic conductivity in the case of nanocrystalline ionic solids. This has potential commercial applications, particularly for oxide ion conductors. However, a detailed knowledge of the microstructure is important in fully understanding the novel properties exhibited by nanocrystalline materials. The final microstructure of a material is dependent on the preparation method used, for example, sol-gel and ball-milling methods are commonly used in the preparation of nanocrystalline oxides. Additionally, there is a problem in maintaining the materials in nanocrystalline form when they are subjected to elevated temperatures. We have been exploring strategies to restrict the growth of nanocrystalline oxides and have found that adding a small amount of an inert material, e.g. SiO 2 or Al 2 O 3 , is particularly effective. We will report XRD and EXAFS studies of nanocrystalline ceria prepared by sol-gel, sol-gel pinned and ball-milling methods and the effect of preparation method on the final microstructure. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Zinc adsorption on clays inferred from atomistic simulations and EXAFS spectroscopy

    International Nuclear Information System (INIS)

    Churakov, S.V.; Daehn, R.

    2012-01-01

    Document available in extended abstract form only. Clay minerals such as illite and montmorillonite are ubiquitous in the environment. Because of their large specific area and high structural charge, they control the migration of heavy metals in the geosphere via different uptake mechanisms. The main processes for the sequestration of trace concentrations of heavy metals are sorption to clay edge sites and incorporation into clay structures. Whereas, sorption is a fast process occurring nearly instantaneously, the incorporation of metal ions into clay minerals occurs over geological time scales. Zn is a divalent transition metal, which shows similar chemical behavior to Ni and Co and can thus also be considered as a natural analogue for radioactive Ni and Co arising from nuclear fuel and radioactive waste from the decommissioning of nuclear power plants. The release of radionuclides from a repository can be considerably retarded due to interactions with clay minerals. For example, bentonite containing >70 wt% di-octahedral alumino-silicate clays is foreseen as a backfill material in the Swiss concept for a high level radioactive waste repository (NAGRA, 2002). Knowing the uptake mechanism of these elements on clays can help to protect the natural environment. In this study ab initio molecular dynamics (MD) calculations were applied to simulate the molecular mechanism of Zn uptake on the edge surfaces of montmorillonite, a di-octahedral clay, and to explain the measured K-edge extended X-ray absorption fine structure (EXAFS) spectra of Zn adsorbed on montmorillonite at different loadings. Two different montmorillonites were chosen for the experimental part of this study: Milos (Island of Milos, Greece) and STx-1 (Gonzales County, Texas, USA) (VANTELON et al., 2003). As a reference for Zn substituted for Al in the clay octahedral sheet a MILOS sample was prepared without adding any Zn. Milos was chosen because it contains 1.8 [mmol/kg] Zn incorporated into the

  8. DEVELOPMENT OF A HIGH RATE HIGH RESOLUTION DETECTOR FOR EXAFS EXPERIMENTS.

    Energy Technology Data Exchange (ETDEWEB)

    DE GERONIMO,G.; O CONNOR,P.; BEUTTENMULLER,R.H.; LI,Z.; KUCZEWSKI,A.J.; SIDDONS,D.P.

    2002-11-10

    A new detector for EXAFS experiments is being developed. It is based on a multi-element Si sensor and dedicated readout ASICs. The sensor is composed of 384 pixels, each having 1 mm{sup 2} area, arranged in four quadrants of 12 x 8 elements, and wire-bonded to 32-channel front-end ASICs. Each channel implements low noise preamplification with self-adaptive continuous reset, high order shaper, band-gap referenced baseline stabilizer, one threshold comparator and two DAC adjustable window comparators, each followed by a 24-bit counter. Fabricated in 0.35{micro}m CMOS dissipates about 8mW per channel. First measurements show at room temperature a resolution of 14 rms electrons without the detector and of 40 rms electrons (340eV) with the detector connected and biased. Cooling at -35C a FWHM of 205eV (167eV from electronics) was measured at the Mn-K{alpha} line. A resolution of about 300eV was measured for rates approaching 100kcps/cm{sup 2} per channel, corresponding to an overall rate in excess of 10MHz/cm{sup 2}. A channel-to-channel threshold dispersion after DACs adjustment of 2.5 rms electrons was also measured.

  9. XANES, EXAFS and Kbeta spectroscopic studies of the oxygen-evolving complex in Photosystem II

    Energy Technology Data Exchange (ETDEWEB)

    Robblee, John Henry [Univ. of California, Berkeley, CA (United States)

    2000-12-01

    A key question for the understanding of photosynthetic water oxidation is whether the four oxidizing equivalents necessary to oxidize water to dioxygen are accumulated on the four Mn ions of the oxygen evolving complex (OEC), or whether some ligand-centered oxidations take place before the formation and release of dioxygen during the S3 → [S4] → S0 transition. Progress in instrumentation and flash sample preparation allowed us to apply Mn Kβ X-ray emission spectroscopy (Kb XES) to this problem for the first time. The Kβ XES results, in combination with Mn X-ray absorption near-edge structure (XANES) and electron paramagnetic resonance (EPR) data obtained from the same set of samples, show that the S2 → S3 transition, in contrast to the S0 → S1 and S1 → S2 transitions, does not involve a Mn-centered oxidation. This is rationalized by manganese μ-oxo bridge radical formation during the S2 → S3 transition. Using extended X-ray absorption fine structure (EXAFS) spectroscopy, the local environment of the Mn atoms in the S0 state has been structurally characterized. These results show that the Mn-Mn distance in one of the di-μ-oxo-bridged Mn-Mn moieties increases from 2.7 Å in the S1} state to 2.85 Å in the S0 state. Furthermore, evidence is presented that shows three di-μ-oxo binuclear Mn2 clusters may be present in the OEC, which is contrary to the widely held theory that two such clusters are present in the OEC. The EPR properties of the S0 state have been investigated and a characteristic ''multiline'' signal in the S0 state has been discovered in the presence of methanol. This provides the first direct confirmation that the native S0 state is paramagnetic. In addition, this signal was simulated using parameters derived from three

  10. EXAFS analysis of full color glasses and glass ceramics: local order and color

    International Nuclear Information System (INIS)

    Santa Cruz, Petrus A.; Sa, Gilberto F. de; Malta, Oscar L.; Silva, Jose expedito Cavalcante

    1996-01-01

    The generation and control of the relative intensities of the primary additive colors in solid state light emitters is very important to the development of higher resolution media, used in color monitors, solid state sensors, large area and flat displays and other optoelectronic devices. We have developed a multi-doped glassy material named FCG (full color glass, to generate and to control the primary light colors, allowing the simulation of any color of light by additive synthesis. Tm(III), Tb(III) and Eu(III) ions were used (0.01 to 5.0 mol%) as blue, green and red narrow emitters. A wide color gamut was obtained under ultraviolet excitation by varying the material composition. The chromaticity diagram is covered, including the white simulation. We proposed a mechanism to control the chromaticity of a fixed composition of the material, using the Er (III) as a selective quencher that may be deactivated by infrared excitation. Although this new material presents at this time a high efficiency, it may be improved because the energy transfer between the rare earth triad may be still reduced. Optical spectroscopy measurements confirms that it is still possible to improve the efficiency of the FCC material. EXAFS analysis will be used to probe the local environment around the triad of rare earth that generates the primary colors. For this purpose we have prepared single doped glasses with each component of the triad with the same concentration than FCG. The devitrification of these glasses will be analyzed in order to produce glassceramics with ion segregation. (author)

  11. Geological and anthropogenic factors influencing mercury speciation in mine wastes: An EXAFS spectroscopy study

    Science.gov (United States)

    Kim, C.S.; Rytuba, J.J.; Brown, Gordon E.

    2004-01-01

    The speciation of Hg is a critical determinant of its mobility, reactivity, and potential bioavailability in mine-impacted regions. Furthermore, Hg speciation in these complex natural systems is influenced by a number of physical, geological, and anthropogenic variables. In order to investigate the degree to which several of these variables may affect Hg speciation, extended X-ray absorption fine structure (EXAFS) spectroscopy was used to determine the Hg phases and relative proportions of these phases present in Hg-bearing wastes from selected mine-impacted regions in California and Nevada. The geological origin of Hg ore has a significant effect on Hg speciation in mine wastes. Specifically, samples collected from hot-spring Hg deposits were found to contain soluble Hg-chloride phases, while such phases were largely absent in samples from silica-carbonate Hg deposits; in both deposit types, however, Hg-sulfides in the form of cinnabar (HgS, hex.) and metacinnabar (HgS, cub.) dominate. Calcined wastes in which Hg ore was crushed and roasted in excess of 600??C, contain high proportions of metacinnabar while the main Hg-containing phase in unroasted waste rock samples from the same mines is cinnabar. The calcining process is thought to promote the reconstructive phase transformation of cinnabar to metacinnabar, which typically occurs at 345??C. The total Hg concentration in calcines is strongly correlated with particle size, with increases of nearly an order of magnitude in total Hg concentration between the 500-2000 ??m and process, identified the presence of Hg-sulfides and schuetteite (Hg3O2SO4), which may have formed as a result of long-term Hg(0) burial in reducing high-sulfide sediments. ?? 2003 Elsevier Ltd. All rights reserved.

  12. The geochemical behaviour of selenium in the Boom Clay system - a XANES and EXAFS study

    International Nuclear Information System (INIS)

    2S, KULeuven, B-3001Leuven (Belgium))" data-affiliation=" (Center for surface Chemistry and Catalysis - M2S, KULeuven, B-3001Leuven (Belgium))" >Breynaert, Eric; 2S, KULeuven, B-3001Leuven (Belgium))" data-affiliation=" (Center for surface Chemistry and Catalysis - M2S, KULeuven, B-3001Leuven (Belgium))" >Dom, Dirk; 2S, KULeuven, B-3001Leuven (Belgium))" data-affiliation=" (Center for surface Chemistry and Catalysis - M2S, KULeuven, B-3001Leuven (Belgium))" >Vancluysen, Jacqueline; 2S, KULeuven, B-3001Leuven (Belgium))" data-affiliation=" (Center for surface Chemistry and Catalysis - M2S, KULeuven, B-3001Leuven (Belgium))" >Kirschhock, Christine E.A.; 2S, KULeuven, B-3001Leuven (Belgium))" data-affiliation=" (Center for surface Chemistry and Catalysis - M2S, KULeuven, B-3001Leuven (Belgium))" >Maes, Andre; Scheinost, Andreas C.

    2010-01-01

    Document available in extended abstract form only. In Belgium, the Boom Clay formation is studied as a reference host formation for the geological disposal of high-level and long-lived radioactive waste for more than 30 years. This formation mainly consists of mixed clay minerals (illite, inter-stratified illite-smectite), pyrite and immobile and dissolved natural organic matter. Since it provides good sorption capacities, very low permeability, and chemically reducing conditions due to the presence of pyrite (FeS 2 ), the Boom clay formation itself is considered to be the main barrier preventing radionuclide migration from the geological repository. Within this concept for geological storage Se 79 has been identified as one of the critical elements contributing to the final dose to man. Although the sorption and migration behaviour of Se in the Boom Clay system has been thoroughly studied, the speciation of Se in the Boom Clay system has never been identified spectroscopically. In all previous studies, the interpretation of the behaviour of Se in Boom Clay conditions has always been based on circumstantial evidence such as solubility measurements or comparison with the spectroscopically identified speciation of Se in model systems. Based on the XANES analysis, selenite is transformed into Se 0 confirming the previously proposed reduction of selenite in the Boom Clay system. Combination of the mass-balance for Se with the results from linear combination analysis of the XANES spectra provided new evidence for the sorption-reduction mechanism proposed to explain the interaction between Se(IV) and the BC solid phase. In addition, evidence was found that that the fate of Se(IV) in the BC system is completely dominated by its interaction with pyrite present in the Boom Clay. The combined EXAFS analysis of Se in Se 0 reference phases (hexagonal, monoclinic, Se-loaded pyrite) allowed to elucidate further details on the short-range structure of the reaction products formed

  13. EXAFS Characterization of Dendrimer-Derived Pt/γ-Al2O3

    International Nuclear Information System (INIS)

    Siani, A.; Alexeev, O. S.; Williams, C. T.; Ploehn, H. J.; Amiridis, M. D.

    2007-01-01

    The various steps involved in the preparation of a Pt/γ-Al2O3 material using hydroxyl-terminated generation four (G4OH) PAMAM dendrimers as templates were monitored by EXAFS. The results indicate that Cl ligands in the Pt precursors (H2PtCl6 and K2PtCl4) were partially replaced by aquo ligands upon hydrolysis to form [PtCl3(H2O)3]+ and [PtCl2(H2O)2] species. After interaction of such species with G4OH, Cl ligands from the first coordination shell of Pt were further replaced by nitrogen atoms from the dendrimer interior, indicating the complexation of Pt with the dendrimer. This process was accompanied by a transfer of the electron density from the dendrimer to Pt, indicating that the former plays the role of a ligand. Following treatment of the H2PtCl6/G4OH and K2PtCl4/G4OH composites with NaBH4, no substantial changes were detecteded in the electronic or coordination environment of Pt, and no formation of metal nanoparticles was observed. However, when the reduction treatment was performed with H2, the formation of extremely small Pt clusters incorporating no more than 4 Pt atoms was observed. These Pt species remained strongly bonded to the dendrimer and their nuclearity depends on the length of the H2 treatment. Formation of Pt nanoparticles with an average diameter of approximately 10 A was finally observed after the deposition of H2PtCl6/G4OH on γ-Al2O3 and drying, suggesting that their formation may be related to the collapse of the dendrimer structure. The Pt nanoparticles formed appear to have high mobility, since subsequent thermal treatment in O2/H2 led to further sintering

  14. Scanning table

    CERN Multimedia

    1960-01-01

    Before the invention of wire chambers, particles tracks were analysed on scanning tables like this one. Today, the process is electronic and much faster. Bubble chamber film - currently available - (links can be found below) was used for this analysis of the particle tracks.

  15. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  16. Macroscopic and microscopic investigation of Ni(II) sequestration on diatomite by batch, XPS, and EXAFS techniques.

    Science.gov (United States)

    Sheng, Guodong; Yang, Shitong; Sheng, Jiang; Hu, Jun; Tan, Xiaoli; Wang, Xiangke

    2011-09-15

    Sequestration of Ni(II) on diatomite as a function of time, pH, and temperature was investigated by batch, XPS, and EXAFS techniques. The ionic strength-dependent sorption at pH < 7.0 was consistent with outer-sphere surface complexation, while the ionic strength-independent sorption at pH = 7.0-8.6 was indicative of inner-sphere surface complexation. EXAFS results indicated that the adsorbed Ni(II) consisted of ∼6 O at R(Ni-O) ≈ 2.05 Å. EXAFS analysis from the second shell suggested that three phenomena occurred at the diatomite/water interface: (1) outer-sphere and/or inner-sphere complexation; (2) dissolution of Si which is the rate limiting step during Ni uptake; and (3) extensive growth of surface (co)precipitates. Under acidic conditions, outer-sphere complexation is the main mechanism controlling Ni uptake, which is in good agreement with the macroscopic results. At contact time of 1 h or 1 day or pH = 7.0-8.0, surface coprecipitates occur concurrently with inner-sphere complexes on diatomite surface, whereas at contact time of 1 month or pH = 10.0, surface (co)precipitates dominate Ni uptake. Furthermore, surface loading increases with temperature increasing, and surface coprecipitates become the dominant mechanism at elevated temperature. The results are important to understand Ni interaction with minerals at the solid-water interface, which is helpful to evaluate the mobility of Ni(II) in the natural environment.

  17. Interpretation of the U L3-edge EXAFS in uranium dioxide using molecular dynamics and density functional theory simulations

    International Nuclear Information System (INIS)

    Bocharov, Dmitry; Chollet, Melanie; Krack, Matthias; Bertsch, Johannes; Grolimund, Daniel; Martin, Matthias; Kuzmin, Alexei; Purans, Juris; Kotomin, Eugene

    2016-01-01

    X-ray absorption spectroscopy is employed to study the local structure of pure and Cr-doped UO 2 at 300 K. The U L 3 -edge EXAFS spectrum is interpreted within the multiplescattering (MS) theory using the results of the classical and ab initio molecular dynamics simulations, allowing us to validate the accuracy of theoretical models. The Cr K-edge XANES is simulated within the full-multiple-scattering formalism considering a substitutional model (Cr at U site). It is shown that both unrelaxed and relaxed structures, produced by ab initio density functional theory (DFT) calculations, fail to describe the experiment. (paper)

  18. In situ Ru K-edge EXAFS of CO adsorption on a Ru modified Pt/C fuel cell catalyst

    International Nuclear Information System (INIS)

    Rose, Abigail; Bilsborrow, Robert; King, Colin R.; Ravikumar, M.K.; Qian Yangdong; Wiltshire, Richard J.K.; Crabb, Eleanor M.; Russell, Andrea E.

    2009-01-01

    The Ru-CO bond of CO adsorbed on a Ru modified Pt/C fuel cell catalyst has been directly probed by in situ EXAFS at the Ru K-edge, providing evidence of a CO:metal surface atom ratio greater than 1:1 and that CO is adsorbed at bridging sites associated with Ru atoms at the surface of the catalyst nanoparticles. This result illustrates the limitations of single crystal models as representations of the bonding of adsorbed species at nanoparticle surfaces.

  19. Scanning holograms

    International Nuclear Information System (INIS)

    Natali, S.

    1984-01-01

    This chapter reports on the scanning of 1000 holograms taken in HOBC at CERN. Each hologram is triggered by an interaction in the chamber, the primary particles being pions at 340 GeV/c. The aim of the experiment is the study of charm production. The holograms, recorded on 50 mm film with the ''in line'' technique, can be analyzed by shining a parallel expanded laser beam through the film, obtaining immediately above it the real image of the chamber which can then be scanned and measured with a technique half way between emulsions and bubble chambers. The results indicate that holograms can be analyzed as quickly and reliably as in other visual techniques and that to them is open the same order of magnitude of large scale experiments

  20. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  1. New insight on the local structure of Cu2+ ion in the solution of CuBr2 by EXAFS studies

    International Nuclear Information System (INIS)

    Yu Meijuan; Chu Wangsheng; Chen Xing; Wu Ziyu

    2009-01-01

    CuBr 2 solutions at different concentrations were studied by extended X-ray absorption fine structure (EXAFS) at the Cu K edge. In the saturated solution Cu 2+ ions have chemical bonds with 3.0 oxygen atoms and 0.9 Br ion at about 1.96 A and 2.42 A, respectively. It indicates that the CuBr 4 -2 configuration exists with a ratio of 25% under this condition. In the dilute solutions no evidence of Br ions contributions in the first shell around Cu 2+ ions occurs. The almost identical X-ray absorption near edge structure (XANES) and EXAFS characters address similar local environments around Cu 2+ in agreement with results of the EXAFS fit taking into account only the contributions of Cu-O bonds.

  2. New insight on the local structure of Cu{sup 2+} ion in the solution of CuBr{sub 2} by EXAFS studies

    Energy Technology Data Exchange (ETDEWEB)

    Yu Meijuan; Chu Wangsheng; Chen Xing; Wu Ziyu, E-mail: wuzy@ustc.edu.c [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049 (China)

    2009-11-15

    CuBr{sub 2} solutions at different concentrations were studied by extended X-ray absorption fine structure (EXAFS) at the Cu K edge. In the saturated solution Cu{sup 2+} ions have chemical bonds with 3.0 oxygen atoms and 0.9 Br ion at about 1.96 A and 2.42 A, respectively. It indicates that the CuBr{sub 4}{sup -2} configuration exists with a ratio of 25% under this condition. In the dilute solutions no evidence of Br ions contributions in the first shell around Cu{sup 2+} ions occurs. The almost identical X-ray absorption near edge structure (XANES) and EXAFS characters address similar local environments around Cu{sup 2+} in agreement with results of the EXAFS fit taking into account only the contributions of Cu-O bonds.

  3. Selenium Sequestration in a Cationic Layered Rare Earth Hydroxide: A Combined Batch Experiments and EXAFS Investigation.

    Science.gov (United States)

    Zhu, Lin; Zhang, Linjuan; Li, Jie; Zhang, Duo; Chen, Lanhua; Sheng, Daopeng; Yang, Shitong; Xiao, Chengliang; Wang, Jianqiang; Chai, Zhifang; Albrecht-Schmitt, Thomas E; Wang, Shuao

    2017-08-01

    Selenium is of great concern owing to its acutely toxic characteristic at elevated dosage and the long-term radiotoxicity of 79 Se. The contents of selenium in industrial wastewater, agricultural runoff, and drinking water have to be constrained to a value of 50 μg/L as the maximum concentration limit. We reported here the selenium uptake using a structurally well-defined cationic layered rare earth hydroxide, Y 2 (OH) 5 Cl·1.5H 2 O. The sorption kinetics, isotherms, selectivity, and desorption of selenite and selenate on Y 2 (OH) 5 Cl·1.5H 2 O at pH 7 and 8.5 were systematically investigated using a batch method. The maximum sorption capacities of selenite and selenate are 207 and 124 mg/g, respectively, both representing the new records among those of inorganic sorbents. In the low concentration region, Y 2 (OH) 5 Cl·1.5H 2 O is able to almost completely remove selenium from aqueous solution even in the presence of competitive anions such as NO 3 - , Cl - , CO 3 2- , SO 4 2- , and HPO 4 2- . The resulting concentration of selenium is below 10 μg/L, well meeting the strictest criterion for the drinking water. The selenate on loaded samples could be desorbed by rinsing with concentrated noncomplexing NaCl solutions whereas complexing ligands have to be employed to elute selenite for the material regeneration. After desorption, Y 2 (OH) 5 Cl·1.5H 2 O could be reused to remove selenate and selenite. In addition, the sorption mechanism was unraveled by the combination of EDS, FT-IR, Raman, PXRD, and EXAFS techniques. Specifically, the selenate ions were exchanged with chloride ions in the interlayer space, forming outer-sphere complexes. In comparison, besides anion exchange mechanism, the selenite ions were directly bound to the Y 3+ center in the positively charged layer of [Y 2 (OH) 5 (H 2 O)] + through strong bidentate binuclear inner-sphere complexation, consistent with the observation of the higher uptake of selenite over selenate. The results presented in

  4. Spin Equilibria in Monomeric Manganocenes: Solid State Magnetic and EXAFS Studies

    Energy Technology Data Exchange (ETDEWEB)

    Walter, M. D.; Sofield, C. D.; Booth, C. H.; Andersen, R. A.

    2009-02-09

    Magnetic susceptibility measurements and X-ray data confirm that tert-butyl-substituted manganocenes [(Me{sub 3}C){sub n}C{sub 5}H{sub 5?n}]{sub 2}Mn (n = 1, 2) follow the trend previously observed with the methylated manganocenes; that is, electron-donating groups attached to the Cp ring stabilize the low-spin (LS) electronic ground state relative to Cp{sub 2}Mn and exhibit higher spin-crossover (SCO) temperatures. However, introducing three CMe{sub 3} groups on each ring gives a temperature-invariant high-spin (HS) state manganocene. The origin of the high-spin state in [1,2,4-(Me{sub 3}C){sub 3}C{sub 5}H{sub 2}]{sub 2}Mn is due to the significant bulk of the [1,2,4-(Me{sub 3}C){sub 3}C{sub 5}H{sub 2}]{sup -} ligand, which is sufficient to generate severe inter-ring steric strain that prevents the realization of the low-spin state. Interestingly, the spin transition in [1,3-(Me{sub 3}C){sub 2}C{sub 5}H{sub 3}]{sub 2}Mn is accompanied by a phase transition resulting in a significant irreversible hysteresis ({Delta}T{sub c} = 16 K). This structural transition was also observed by extended X-ray absorption fine-structure (EXAFS) measurements. Magnetic susceptibility studies and X-ray diffraction data on SiMe{sub 3}-substituted manganocenes [(Me{sub 3}Si){sub n}C{sub 5}H{sub 5-n}]{sub 2}Mn (n = 1, 2, 3) show high-spin configurations in these cases. Although tetra- and hexasubstituted manganocenes are high-spin at all accessible temperatures, the disubstituted manganocenes exhibit a small low-spin admixture at low temperature. In this respect it behaves similarly to [(Me{sub 3}C)(Me{sub 3}Si)C{sub 5}H{sub 3}]{sub 2}Mn, which has a constant low-spin admixture up to 90 K and then gradually converts to high-spin. Thermal spin-trapping can be observed for [(Me{sub 3}C)(Me{sub 3}Si)C{sub 5}H{sub 3}]{sub 2}Mn on rapid cooling.

  5. X-ray absorption spectroscopy: EXAFS and XANES - A versatile tool to study the atomic and electronic structure of materials

    International Nuclear Information System (INIS)

    Alp, E.E.; Mini, S.M.; Ramanathan, M.

    1990-01-01

    X-ray absorption spectroscopy (XAS) had been an essential tool to gather spectroscopic information about atomic energy level structure in the early decades of this century. The correct interpretation of the oscillatory structure in the x-ray absorption cross-section above the absorption edge has transformed XAS from a spectroscopic tool to a structural technique. EXAFS (Extended X-ray Absorption Fine Structure) yields information about the interatomic distances, near neighbor coordination numbers, and lattice dynamics. XANES (X-ray Absorption Near Edge Structure), on the other hand, gives information about the valence state, energy bandwidth and bond angles. Today, there are about 50 experimental stations in various synchrotrons around the world dedicated to collecting x-ray absorption data from the bulk and surfaces of solids and liquids. In this chapter, they will give the basic principles of XAS, explain the information content of essentially two different aspects of the absorption process leading to EXAFS and XANES, and discuss the source and sample limitations

  6. Shape resonances and EXAFS scattering in the $Pt L_{2,3}$ XANES from a Pt electrode

    CERN Document Server

    O'Grady, W E

    1999-01-01

    Atomic hydrogen and oxygen adsorption on a platinum electrode in H /sub 2/SO/sub 4/ and HClO/sub 4/ electrolytes were studied by Pt L /sub 23/ XANES. The Pt electrode was formed of highly dispersed 1.5-3.0 nm particles supported on $9 carbon. A difference procedure utilizing the L/sub 2/ and L/sub 3/ spectra at various applied voltages was used to isolate the electronic and geometric effects in the XANES spectra. At 0.54 V (relative to RHE) the Pt electrode in $9 HClO/sub 4/ is assumed to be "clean". By taking the difference between the spectra at 0.0 and 0.54 V, the Pt-H antibonding state (electronic effect) is isolated and found to have a Fano-resonance line shape. In addition, a $9 significant Pt-H EXAFS scattering (geometric effect) was found for photon energies 0 to 20 eV above the edge. The difference between the spectra at 1.14 and 0.54 V allows isolation of the Pt-O antibonding state and the Pt-O EXAFS $9 scattering. (7 refs).

  7. The application of iterative transformation factor analysis to resolve multi-component EXAFS spectra of uranium(6) complexes with acetic acid as a function of pH

    International Nuclear Information System (INIS)

    Robberg, A.; Reich, T.

    2002-01-01

    Synchrotron-based EXAFS spectroscopy is a powerful technique to obtain structural information on radionuclide complexes in solution. Depending on the chemical conditions of the samples several radionuclide species can coexist in the solution as is often the case for environmentally related samples. All radionuclide species, which may have different near-neighbour environments, contribute to the measured EXAFS signal. In order to isolate the EXAFS spectra of the individual species (pure spectral components), it is necessary, in a first step, to measure a series of samples where their composition is changed by variation of one physico-chemical parameter (e.g. pH, concentration, etc.). For the spectral decomposition it is necessary that the EXAFS signal change as a function of the chosen physico-chemical parameter. In a second step, the series of EXAFS spectra is analysed with Eigen analysis and Iterative Transformation Factor Analysis (ITFA). As a result of the ITFA one obtains: a) for each sample the relative concentration of the structural distinguishable species and b) their corresponding pure spectral components. From the information obtained in a), one can construct a speciation diagram. The pure spectral components contain the structural information of the individual species, which can be extracted by conventional EXAFS analysis. To evaluate our ITFA algorithm for EXAFS analysis of mixtures, we prepared a series of eight solution samples of 0.05 M uranium(VI) and 1 M acetate (Ac) in the pH range of 0.1 to 4.5. From thermodynamic constants it is known that under these conditions up to four species can occur: uranyl hydrate, and the 1:1, 1:2 and 1:3 complexes of uranyl acetate. The uranium L III -edge EXAFS spectra were measured at room temperature in transmission mode at the Rossendorf Beamline (ROBL) at the ESRF. The average bond length between uranium and the equatorial oxygen atoms (O eq ) increases from 2.40 to 2.46 angstrom with increasing pH. This increase

  8. Hydration effects on the molecular structure of silica-supported vanadium oxide catalysts: A combined IR, Raman, UV–vis and EXAFS study

    NARCIS (Netherlands)

    Keller, D.E.; Visser, T.; Soulimani, F.; Koningsberger, D.C.; Weckhuysen, B.M.

    2007-01-01

    The effect of hydration on the molecular structure of silica-supported vanadium oxide catalysts with loadings of 1–16 wt.% V has been systematically investigated by infrared, Raman, UV–vis and EXAFS spectroscopy. IR and Raman spectra recorded during hydration revealed the formation of V–OH groups,

  9. Uranium speciation in 30-year old Freital mine tailings: an EXAFS, {mu}-XRD, and {mu}-XRF study

    Energy Technology Data Exchange (ETDEWEB)

    Scheinost, A.C.; Hennig, C. [Institute of Radiochemistry, FZR, D-01314 Dresden (Germany); Somogyi, A. [Synchrotron Soleil, F-91192 Gif-sur-Yvette (France); Martinez-Criado, G. [ESRF, ID-22, F-38043 Grenoble (France); Knappik, R. [VKTA Rossendorf, D-01314 Dresden (Germany)

    2005-07-01

    Full text of publication follows: Risk assessments of actinide-contaminated soils and sediments require detailed knowledge of actinide speciation and its long-term kinetics. Former Saxonian mine tailings, which have been covered but else left undisturbed, are ideally suited to study changes in uranium speciation over timescales of decades. We investigated the major uranium species in two samples from buried mine tailings using a combination of Synchrotron-based microfocus-techniques ({mu}-XRF, {mu}-XRD with micrometer resolution), bulk EXAFS spectroscopy, and chemical extractions. In sample F1 (5 m depth, oxic, pH 8, U = 440 mg/kg, high Ca, S, Pb, Cu, Zn concentrations), uranium is diffusely distributed among aggregates of layer silicates (muscovite, illite and kaolinite). The chemical extractions and EXAFS results confirm that uranium is sorbed to these minerals, but is not incorporated into their crystal structure. Sorption is also in line with the high pH and low carbonate concentrations in pore water. In sample F3 (12 m depth, oxic, pH 4, U = 430 mg/kg), the combination of {mu}-XRF and {mu}-XRD enabled us to identify several U(IV) and U(VI) containing minerals like coffinite, uraninite, uranyl hydroxide, and vanuralite. Only a minor part of U is sorbed to layer silicates as confirmed by chemical extractions and EXAFS spectroscopy. At smaller depth (F1, 5 m), sulfuric acid from the ore extraction procedure was completely neutralized by the construction waste used as cover material, resulting in precipitation of jarosite and gypsum. Even 30 years after the ore extraction, uranium remains highly soluble. At greater depth (F3, 12 m), the low pH from ore extraction was conserved. The presence of U(IV) minerals suggest either precipitation of secondary (IV) minerals due to microbial redox activity, or incomplete dissolution of primary (IV) minerals due to ore processing inefficiency of these older sediments. The U(IV) minerals were recalcitrant during chemical

  10. Uranium speciation in 30-year old Freital mine tailings: an EXAFS, μ-XRD, and μ-XRF study

    International Nuclear Information System (INIS)

    Scheinost, A.C.; Hennig, C.; Somogyi, A.; Martinez-Criado, G.; Knappik, R.

    2005-01-01

    Full text of publication follows: Risk assessments of actinide-contaminated soils and sediments require detailed knowledge of actinide speciation and its long-term kinetics. Former Saxonian mine tailings, which have been covered but else left undisturbed, are ideally suited to study changes in uranium speciation over timescales of decades. We investigated the major uranium species in two samples from buried mine tailings using a combination of Synchrotron-based microfocus-techniques (μ-XRF, μ-XRD with micrometer resolution), bulk EXAFS spectroscopy, and chemical extractions. In sample F1 (5 m depth, oxic, pH 8, U = 440 mg/kg, high Ca, S, Pb, Cu, Zn concentrations), uranium is diffusely distributed among aggregates of layer silicates (muscovite, illite and kaolinite). The chemical extractions and EXAFS results confirm that uranium is sorbed to these minerals, but is not incorporated into their crystal structure. Sorption is also in line with the high pH and low carbonate concentrations in pore water. In sample F3 (12 m depth, oxic, pH 4, U = 430 mg/kg), the combination of μ-XRF and μ-XRD enabled us to identify several U(IV) and U(VI) containing minerals like coffinite, uraninite, uranyl hydroxide, and vanuralite. Only a minor part of U is sorbed to layer silicates as confirmed by chemical extractions and EXAFS spectroscopy. At smaller depth (F1, 5 m), sulfuric acid from the ore extraction procedure was completely neutralized by the construction waste used as cover material, resulting in precipitation of jarosite and gypsum. Even 30 years after the ore extraction, uranium remains highly soluble. At greater depth (F3, 12 m), the low pH from ore extraction was conserved. The presence of U(IV) minerals suggest either precipitation of secondary (IV) minerals due to microbial redox activity, or incomplete dissolution of primary (IV) minerals due to ore processing inefficiency of these older sediments. The U(IV) minerals were recalcitrant during chemical extractions

  11. Determination of sorption mechanisms of radionuclides onto clay minerals using extended x-ray absorption fine structure (EXAFS) spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Daehn, R.; Scheidegger, A.; Baeyens, B.; Bradbury, M.H

    2001-03-01

    Much of the experimental work in the Waste Management Laboratory at PSI concentrates on trying to understand the processes and mechanisms which govern the release of safety-relevant radionuclides from waste matrices, and their transport through engineered barrier systems and the surrounding geosphere. For this reason, detailed sorption studies of radionuclides (Cs, Sr, Ni, Zn, Eu, Am, Th and Se) in clay and cement systems are being conducted. The sorption and modelling studies are combined with kinetic investigations and advanced spectroscopic and microscopic methods in order to understand the sorption mechanism on an atomic level. This approach is part of a new multidisciplinary research field called Molecular Environmental Science (MES). In this paper, a case study of Ni sorption on montmorillonite is presented to illustrate how EXAFS can be used successfully to better understand sorption processes. (author)

  12. Determination of sorption mechanisms of radionuclides onto clay minerals using extended x-ray absorption fine structure (EXAFS) spectroscopy

    International Nuclear Information System (INIS)

    Daehn, R.; Scheidegger, A.; Baeyens, B.; Bradbury, M.H.

    2001-01-01

    Much of the experimental work in the Waste Management Laboratory at PSI concentrates on trying to understand the processes and mechanisms which govern the release of safety-relevant radionuclides from waste matrices, and their transport through engineered barrier systems and the surrounding geosphere. For this reason, detailed sorption studies of radionuclides (Cs, Sr, Ni, Zn, Eu, Am, Th and Se) in clay and cement systems are being conducted. The sorption and modelling studies are combined with kinetic investigations and advanced spectroscopic and microscopic methods in order to understand the sorption mechanism on an atomic level. This approach is part of a new multidisciplinary research field called Molecular Environmental Science (MES). In this paper, a case study of Ni sorption on montmorillonite is presented to illustrate how EXAFS can be used successfully to better understand sorption processes. (author)

  13. EXAFS analysis of a human Cu,Zn SOD isoform focused using non-denaturing gel electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Chevreux, Sylviane; Roudeau, Stephane; Deves, Guillaume; Ortega, Richard [Laboratoire de Chimie Nucleaire Analytique et Bioenvironnementale, CNRS UMR5084, Universite Bordeaux 1, Chemin du Solarium, F-33175 Gradignan cedex (France); Solari, Pier Lorenzo [Synchrotron SOLEIL, L' Orme des Merisiers, BP 48, F-91192 Gif-sur-Yvette cedex, Saint-Aubin (France); Alliot, Isabelle; Testemale, Denis; Hazemann, Jean Louis, E-mail: ortega@cenbg.in2p3.f [FAME, ESRF, 6 rue Jules Horowitz, BP220, F-38043 Grenoble cedex (France)

    2009-11-15

    Isoelectric point isoforms of a metalloprotein, copper-zinc superoxide dismutase (CuZnSOD), separated on electrophoresis gels were analyzed using X-ray Absorption Spectroscopy. Mutations of this protein are involved in familial cases of amyotrophic lateral sclerosis. The toxicity of mutants could be relied to defects in the metallation state. Our purpose is to establish analytical protocols to study metallation state of protein isoforms such as those from CuZnSOD. We previously highlighted differences in the copper oxidation state between CuZnSOD isoforms using XANES. Here, we present the first results for EXAFS analyses performed at Cu and Zn K-edge on the majoritary expressed isoform of human CuZnSOD separated on electrophoresis gels.

  14. Determination of two- and three-body correlation functions in ionic solutions by means of MD and EXAFS investigations

    International Nuclear Information System (INIS)

    D'Angelo, P.; Pavel, N.V.

    1999-01-01

    The solvation structure of Sr 2+ ions in acetonitrile has been studied by x-ray absorption spectroscopy (XAS) and molecular dynamics (MD) simulations. The extended x-ray absorption fine structure (EXAFS) above the Sr K-edge has been interpreted in the framework of the multiple scattering (MS) formalism and, for the first time, clear evidence of MS contributions has been found for non-complexing ions in solution. Molecular dynamics has been used to generate the partial pair g(r) and the three-body g(r 1 , r 2 , θ) distribution functions from which a model χ(k) has been constructed. An excellent agreement has been found between the theoretical and experimental data. This result demonstrates the ability of the XAS technique in probing three-body correlation functions in solutions. (au)

  15. EXAFS analysis of a human Cu,Zn SOD isoform focused using non-denaturing gel electrophoresis

    Science.gov (United States)

    Chevreux, Sylviane; Solari, Pier Lorenzo; Roudeau, Stéphane; Deves, Guillaume; Alliot, Isabelle; Testemale, Denis; Hazemann, Jean Louis; Ortega, Richard

    2009-11-01

    Isoelectric point isoforms of a metalloprotein, copper-zinc superoxide dismutase (CuZnSOD), separated on electrophoresis gels were analyzed using X-ray Absorption Spectroscopy. Mutations of this protein are involved in familial cases of amyotrophic lateral sclerosis. The toxicity of mutants could be relied to defects in the metallation state. Our purpose is to establish analytical protocols to study metallation state of protein isoforms such as those from CuZnSOD. We previously highlighted differences in the copper oxidation state between CuZnSOD isoforms using XANES. Here, we present the first results for EXAFS analyses performed at Cu and Zn K-edge on the majoritary expressed isoform of human CuZnSOD separated on electrophoresis gels.

  16. EXAFS analysis of a human Cu,Zn SOD isoform focused using non-denaturing gel electrophoresis

    International Nuclear Information System (INIS)

    Chevreux, Sylviane; Roudeau, Stephane; Deves, Guillaume; Ortega, Richard; Solari, Pier Lorenzo; Alliot, Isabelle; Testemale, Denis; Hazemann, Jean Louis

    2009-01-01

    Isoelectric point isoforms of a metalloprotein, copper-zinc superoxide dismutase (CuZnSOD), separated on electrophoresis gels were analyzed using X-ray Absorption Spectroscopy. Mutations of this protein are involved in familial cases of amyotrophic lateral sclerosis. The toxicity of mutants could be relied to defects in the metallation state. Our purpose is to establish analytical protocols to study metallation state of protein isoforms such as those from CuZnSOD. We previously highlighted differences in the copper oxidation state between CuZnSOD isoforms using XANES. Here, we present the first results for EXAFS analyses performed at Cu and Zn K-edge on the majoritary expressed isoform of human CuZnSOD separated on electrophoresis gels.

  17. EXAFS study on the neptunium(V) complexation by various humic acids under neutral pH conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, S.; Schmeide, K.; Brendler, V.; Heise, K.H.; Bernhard, G. [Forschungszentrum Rossendorf e.V., Inst. of Radiochemistry, Dresden (Germany); Reich, T. [Forschungszentrum Rossendorf e.V., Inst. of Radiochemistry, Dresden (Germany); Univ. Mainz, Inst. of Nuclear Chemistry (Germany)

    2005-07-01

    The structure of Np(V) humic acid (HA) complexes at pH 7 was studied by extended X-ray absorption fine structure analysis (EXAFS). For the first time, the influence of phenolic OH groups on the complexation of HA and Np(V) in the neutral pH range was investigated using modified HAs with blocked phenolic OH groups and Bio-Rex70, a cation exchange resin having only carboxyl groups as proton exchanging sites. The formation of Np(V) humate complexes was verified by near-infrared (NIR) spectroscopy. Axial Np-O bond distances of 1.84-1.85 Aa were determined for the studied Np(V) humate complexes and the Np(V)-Bio-Rex70 sorbate. In the equatorial plane Np(V) is surrounded by about 3 oxygen atoms with bond lengths of 2.48-2.49 Aa. The comparison of the structural parameters of the Np(V) humates with those of Np(V)-Bio-Rex70 points to the fact that the interaction between HA and Np(V) in the neutral pH range is dominated by carboxylate groups. However, up to now a contribution of phenolic OH groups to the interaction process cannot be excluded completely. The comparison of the obtained structural data for the Np(V) humates to those of Np(V) carboxylates and Np(V) aquo ions reported in the literature indicates that humic acid carboxylate groups predominantly act as monodentate ligands. A differentiation between equatorial coordinated carboxylate groups and water molecules using EXAFS spectroscopy is impossible. (orig.)

  18. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  19. Solution Structures of Highly Active Molecular Ir Water-Oxidation Catalysts from Density Functional Theory Combined with High-Energy X-ray Scattering and EXAFS Spectroscopy.

    Science.gov (United States)

    Yang, Ke R; Matula, Adam J; Kwon, Gihan; Hong, Jiyun; Sheehan, Stafford W; Thomsen, Julianne M; Brudvig, Gary W; Crabtree, Robert H; Tiede, David M; Chen, Lin X; Batista, Victor S

    2016-05-04

    The solution structures of highly active Ir water-oxidation catalysts are elucidated by combining density functional theory, high-energy X-ray scattering (HEXS), and extended X-ray absorption fine structure (EXAFS) spectroscopy. We find that the catalysts are Ir dimers with mono-μ-O cores and terminal anionic ligands, generated in situ through partial oxidation of a common catalyst precursor. The proposed structures are supported by (1)H and (17)O NMR, EPR, resonance Raman and UV-vis spectra, electrophoresis, etc. Our findings are particularly valuable to understand the mechanism of water oxidation by highly reactive Ir catalysts. Importantly, our DFT-EXAFS-HEXS methodology provides a new in situ technique for characterization of active species in catalytic systems.

  20. The structure of well defined SiO2 supported MoO3 clusters during sulfidation : an in situ EXAFS-study

    NARCIS (Netherlands)

    Boer, de M.; Dillen, van A.J.; Koningsberger, D.C.; Geus, J.W.; Kuroda, H.; Ohta, T.

    1993-01-01

    The sulfidation of a well defined MoO3/SiO2 catalyst has been examd. by means of TPS, EXAFS, and TEM. The oxidic clusters in a 5.6 wt% MoO3/SiO2 catalyst are transformed into almost completely sulfided particles (MoOxSy) by O-S exchange at RT. A molybdenum-sulfido particle that resembles the MoS3

  1. In-Plane Structure of Underpotentially Deposited Copper on Gold (111) Determined by Surface EXAFS (Extended X-Ray Absorption Fine Structure).

    Science.gov (United States)

    1988-01-28

    EXAFS is the inverse transform of the two peaks in the RSF using a filtering a12 function to isolate the range between I and 4A. Both the frequency...backscattering of different neighbors. This inverse transform contains only one frequency and its envelope of intensity is the backscattering amplitude function...and the inverse transform of the RSF using a fourier filter between 1 and 4A (Solid line). Insert: Radial Structure Function (RSF) analyzed between

  2. Lanthanide complexes of macrocyclic polyoxovanadates by VO4 units: synthesis, characterization, and structure elucidation by X-ray crystallography and EXAFS spectroscopy.

    Science.gov (United States)

    Nishio, Masaki; Inami, Shinnosuke; Katayama, Misaki; Ozutsumi, Kazuhiko; Hayashi, Yoshihito

    2012-01-16

    Reactions of a tetravanadate anion, [V(4)O(12)](4-), with a series of lanthanide(III) salts yield three types of lanthanide complexes of macrocyclic polyoxovanadates: (Et(4)N)(6)[Ln(III)V(9)O(27)] [Ln = Nd (1), Sm (2), Eu (3), Gd (4), Tb (5), Dy (6)], (Et(4)N)(5)[(H(2)O)Ho(III)(V(4)O(12))(2)] (7), and (Et(4)N)(7)[Ln(III)V(10)O(30)] [Ln = Er (8), Tm (9), Yb (10), Lu (11)]. Lanthanide complexes 1-11 are isolated and characterized by IR, elemental analysis, single-crystal X-ray diffraction, and extended X-ray absorption fine structure spectroscopy (EXAFS). Lanthanide complexes 1-6 are composed of a square-antiprism eight-coordinated Ln(III) center with a macrocyclic polyoxovanadate that is constructed from nine VO(4) tetrahedra through vertex sharing. The structure of 7 is composed of a seven-coordinated Ho(III) center, which exhibits a capped trigonal-prism coordination environment by the sandwiching of two cyclic tetravanadates with a capping H(2)O ligand. Lanthanide complexes 8-11 have a six-coordinated Ln(III) center with a 10-membered vanadate ligand. The structural trend to adopt a larger coordination number for a larger lanthanide ion among the three types of structures is accompanied by a change in the vanadate ring sizes. These lanthanide complexes are examined by EXAFS spectroscopies on lanthanide L(III) absorption edges, and the EXAFS oscillations of each of the samples in the solid state and in acetonitrile are identical. The Ln-O and Ln···V bond lengths obtained from fits of the EXAFS data are consistent with the data from the single-crystal X-ray studies, reflecting retention of the structures in acetonitrile.

  3. EXAFS analysis of intermediate phases in the synthesis of the YBa2Cu3O7-x high-Tc superconductor from xerogel

    International Nuclear Information System (INIS)

    Arcon, I.; Bele, M.; Hribar, M.; Kodre, A.; Pejovnik, S.; Stuhec, M.; Drube, W.

    1994-01-01

    In the synthesis of superconducting cuprate ceramics starting from gels, the advantage of stoichiometric homogeneity of the constituent atoms on the molecular level is exploited. However, x-ray diffraction analysis of samples taken in consecutive temperature points in the process of calcination shows formation of a number of well-crystalized intermediary products. EXAFS spectrometry gives additional insight into the process, providing the information on the neighborhood of constituent atoms in the crystalline as well as amorphous phase. (orig.)

  4. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  5. Behavior and mechanism of Ni(II) uptake on MnO2 by a combination of macroscopic and EXAFS investigation

    International Nuclear Information System (INIS)

    Guodong Sheng; Jiang Sheng; Shitong Yang; Ju Hu; Xiangke Wang

    2011-01-01

    The effects of pH, ionic strength, competing ions and initial metal concentrations on the uptake behavior and mechanism of radioactive Ni(II) onto MnO 2 was investigated using a combination of classical macroscopic methods and the extended X-ray absorption fine structure (EXAFS) spectroscopy technique. The results indicated that the uptake of Ni(II) on MnO 2 is obviously dependent on pH but independent of ionic strength, which suggested that the uptake of Ni(II) onto MnO 2 is attributed to an inner-sphere surface complex rather than an outer-sphere surface complex. EXAFS analysis shows that the hydrated Ni(II) is adsorbed through six-fold coordination with an average Ni-O interatomic distance of 2.04 ± 0.01 A. It can be inferred from the EXAFS analysis that the inner-sphere surface complex of Ni(II) onto MnO 2 is involved in both edge-sharing and corner-sharing linkages. Both the macroscopic uptake data and the molecular level evidence of Ni(II) surface speciation at the MnO 2 -water interfaces should be factored into better prediction of the bioavailability and mobility of Ni(II) in soil and water environment. (author)

  6. EXAFS analysis of the L3 edge of Ce in CeO2: effects of multielectron excitations and final-state mixed valence

    International Nuclear Information System (INIS)

    Fonda, E.; Andreatta, D.; Colavita, P.E.; Vlaic, G.

    1999-01-01

    Cerium oxide (IV) (CeO 2 ) is extensively employed in heterogeneous catalysis, particularly as a promoter of noble metal action in three-way catalysts. For this reason there is a great scientific and economical interest in the development of any possible chemical or structural analysis technique that could provide information on these systems. EXAFS spectroscopy has revealed itself as a powerful technique for structural characterization of such catalysts. Unfortunately, good quality K-edge spectra of cerium are not yet easily obtainable because of the high photon energy required (>40 keV). On the other hand, at lower energies it is easy to collect very good spectra of the L 3 edge (5.5 keV), but L 3 -edge spectra of cerium (IV) are characterized by the presence of two undesired additional phenomena that interfere with EXAFS analysis: final-state mixed-valence behaviour and intense multi-electron excitations. Here, a comparative analysis of the K, L 3 , L 2 and L 1 edges of Ce in CeO 2 has been made and a procedure for obtaining structural parameters from L 3 -edge EXAFS, even in the presence of these features, has been developed. This procedure could allow further studies of catalytic compounds containing tetravalent cerium surrounded by oxygen ligands. (au)

  7. Shining X-rays on catalysts at work

    Energy Technology Data Exchange (ETDEWEB)

    Grunwaldt, J-D, E-mail: jdg@kt.dtu.d [Technical University of Denmark, Department of Chemical and Biochemical Engineering, Building 229, DK-2800 Kgs. Lyngby (Denmark)

    2009-11-15

    Structure-performance relationships gained by studying catalysts at work are considered the key to further development of catalysts underlined here by a brief overview on our research in this area. The partial oxidation of methane to hydrogen and carbon monoxide over Pt- and Rh-based catalysts and the total combustion of hydrocarbons demonstrate the importance of structural identification of catalysts in its working state and the measurement of the catalytic performance at the same time. Moreover, proper cell design is a key both here and in liquid phase reactions including preparation or high pressure reactions. In several cases structural changes during preparation, activation and reaction occur on a subminute scale or the catalyst structure varies inside a reactor as a result of temperature or concentration gradients. This, additionally, requires time and spatial resolution. Examples from time-resolved QEXAFS studies during the partial oxidation of methane over Pt- and Rh-based catalysts demonstrate some of the recent developments of the technique (use not only of Si(111) but also Si(311) crystals, angular encoder, full EXAFS spectra at subsecond recording time, and modulation excitation spectroscopy). In order to obtain spectroscopic information on the oxidation state inside a microreactor, scanning and full field X-ray microscopy with X-ray absorption spectroscopic contrast were achieved under reaction conditions. If a microbeam is applied, fast scanning techniques like QEXAFS are required. In this way, even X-ray absorption spectroscopic tomographic images of a slice of a microreactor were obtained. The studies were recently extended to spatiotemporal studies that give important insight into the dynamics of the catalyst structure in a spatial manner with subsecond time-resolution.

  8. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  9. Evidence from EXAFS for Different Ta/Ti Site Occupancy in High Critical Current Density Nb3Sn Superconductor Wires.

    Science.gov (United States)

    Heald, Steve M; Tarantini, Chiara; Lee, Peter J; Brown, Michael D; Sung, ZuHawn; Ghosh, Arup K; Larbalestier, David C

    2018-03-19

    To meet critical current density, J c , targets for the Future Circular Collider (FCC), the planned replacement for the Large Hadron Collider (LHC), the high field performance of Nb 3 Sn must be improved, but champion J c values have remained static for the last 10 years. Making the A15 phase stoichiometric and enhancing the upper critical field H c2 by Ti or Ta dopants are the standard strategies for enhancing high field performance but detailed recent studies show that even the best modern wires have broad composition ranges. To assess whether further improvement might be possible, we employed Extended X-ray Absorption Fine Structure (EXAFS) to determine the lattice site location of dopants in modern high-performance Nb 3 Sn strands with J c values amongst the best so far achieved. Although Ti and Ta primarily occupy the Nb sites in the A15 structure, we also find significant Ta occupancy on the Sn site. These findings indicate that the best performing Ti-doped stand is strongly sub-stoichiometric in Sn and that antisite disorder likely explains its high average H c2 behavior. These new results suggest an important role for dopant and antisite disorder in minimizing superconducting property distributions and maximizing high field J c properties.

  10. Towards advanced structural analysis of iron oxide clusters on the surface of γ-Al{sub 2}O{sub 3} using EXAFS

    Energy Technology Data Exchange (ETDEWEB)

    Boubnov, Alexey [Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology, Kaiserstr. 12, D-76131 Karlsruhe (Germany); Institute of Catalysis Research and Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Roppertz, Andreas [Institute of Energy Process Engineering and Chemical Engineering, Chair of Reaction Engineering, Technical University of Freiberg, Fuchsmuehlenweg 9, D-09599 Freiberg (Germany); Kundrat, Matthew D. [Center for Functional Nanostructures and Institute of Physical Chemistry, Karlsruhe Institute of Technology, Kaiserstr. 12, D-76131 Karlsruhe (Germany); Mangold, Stefan [Institut für Beschleunigerphysik und Technologie (IBPT), Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Reznik, Boris [Institute of Applied Geosciences, Karlsruhe Institute of Technology, Kaiserstr. 12, D-76131 Karlsruhe (Germany); Jacob, Christoph R. [Center for Functional Nanostructures and Institute of Physical Chemistry, Karlsruhe Institute of Technology, Kaiserstr. 12, D-76131 Karlsruhe (Germany); Institute of Physical and Theoretical Chemistry, TU Braunschweig, Hans-Sommer-Str. 10, D-38106 Braunschweig (Germany); Kureti, Sven [Institute of Energy Process Engineering and Chemical Engineering, Chair of Reaction Engineering, Technical University of Freiberg, Fuchsmuehlenweg 9, D-09599 Freiberg (Germany); Grunwaldt, Jan-Dierk, E-mail: grunwaldt@kit.edu [Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology, Kaiserstr. 12, D-76131 Karlsruhe (Germany); Institute of Catalysis Research and Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany)

    2016-11-15

    Highlights: • Analysis of isolated and oligomeric FeOx (x = 4, 5) on Al{sub 2}O{sub 3} by XANES and EXAFS. • Iron is trivalent and is mainly located at octahedral lattice sites of Al{sub 2}O{sub 3}. • Low Fe loading (0.1%) guarantees high dispersion of catalytically active iron sites. • Surface Fe-cluster on Al{sub 2}O{sub 3} and DFT-optimised Fe-doped Al{sub 2}O{sub 3} as input models for EXAFS. • Interactions of iron with support are well-accounted for using realistic models. - Abstract: Iron oxide centres are structurally investigated in 0.1% Fe/γ-Al{sub 2}O{sub 3}, which is known as highly active catalyst, for instance in the oxidation of CO. The sample was characterised by using X-ray absorption spectroscopy (XAS) in terms of X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), Mössbauer spectroscopy, X-ray diffraction (XRD) and transmission electron microscopy (TEM). These analyses evidenced high dispersion of the iron oxide entities without significant presence of bulk-like aggregates associated with the low Fe content of the catalyst. A library of structural models of Al{sub 2}O{sub 3}-supported surface Fe was created as input for EXAFS fitting. Additionally, several model structures of Fe substituting Al ions in bulk γ-Al{sub 2}O{sub 3} were created with optimised geometry based on density-functional theory (DFT) calculations. From EXAFS refinement of the best 8 out of 24 models, it was found that the trivalent Fe ions are coordinated by 4–5 oxygen atoms and are located on octahedral lattice sites of the exposed surfaces of γ-Al{sub 2}O{sub 3}. These iron oxide species exist mainly as a mixture of monomeric and binuclear species and due to the low concentration represent suitable model systems as alternative to single crystal systems for structure-function relationships.

  11. Location of rare-earth dopants on LiCAF and LiSAF laser hosts via XRD, EXAFS and computer modeling technique

    International Nuclear Information System (INIS)

    Valerio, Mario Ernesto Giroldo; Amaral, Jomar Batista de; Baldochi, Sonia Licia Vera; Mazzocchi, L.; Sasaki, Jose Marcos; Jackson, Robert A.

    2004-01-01

    Full text: Cr-doped LiCaAlF 6 (LiCAF) and LiSrAlF 6 (LiSAF) were used as laser operating in the near infrared region. Ce-doped LiCAF and LiSAF have been reported as leading candidates for tunable all-solid-state lasers in the UV region. Spectroscopic properties of LiCaAlF 6 : Nd suggest that this crystal can be used as selective optical filter and refractive element for 157 nm photolithography. The question of whether the RE dopant will prefer the Li + , the M 2+ site or the Al 3+ site is not yet known. Nevertheless most of the optical properties of these hosts including their laser action depend on the local symmetry, charge compensation mechanism and possible deformation of the lattice. In the present work, Powder X-ray Diffraction (XRD), X-ray Absorption Spectroscopy (XAS), Spectro fluorimetry, combined with computer modeling, were used to study the local structure around the dopant and determine the site occupied by them and also the distance and nature of the co-ordinating atoms. The compounds were prepared from commercially available CaF2 and SrF2 powders of high purity; LiF previously purified by the zone melting method, and AlF3 and RE dopants obtained from the hydro fluorination of commercial Al 2 O 3 . The synthesis of 2 mol % RE doped LiCAF and LiSAF samples were performed in a platinum reactor. The compositions were 2 mol % LiF and AlF3 enriched to compensate for their high vaporization. Powder XRD measurements were performed at room temperature in a Rigaku DMAX diffractometer in step scan mode using Cu K radiation. The Rietveld method (DBWS-9807a software) was employed in the analysis of the patterns. It was found that in the doped samples the concentration of the LiCAF or LiSAF phases are 84-95% and a small amount of AlF 3 and α - Li 3 AlF 6 were formed. The XAS experiments were performed on and above the L III absorption edge of the Er, Ho and Nd ions in fluorescence and transmission mode at room temperature in the XAS station at the LNLS, Campinas

  12. An EXAFS Study on the Local Structure Around Iron in Atmospheric Aerosols Collected in the Qingdao Area

    Directory of Open Access Journals (Sweden)

    Tiandou Hu

    2003-01-01

    Full Text Available The existing forms of Fe are of great interest since they have a profound effect on the biological availability of Fe. In this work, aerosol samples collected in different seasons and at different locations in the Qingdao region were examined by means of extended X-ray absorption fine structure (EXAFS K-edge analysis of Fe, X-ray diffraction (XRD and Fe content analysis. The results showed that an iron ion in aerosol particles is surrounded on average by 5.8 (coordinated O ions. For the six samples examined, the coordination number of the first Fe-O coordination subshell is always 3 with a coordination distance (with O in the range of 1.952~1.966±0.002 Å, while the coordination number of the second subshell varies from 2.2 to 3.0 with a coordination distance of 2.108±0.002 Å. The coordination is approximately consistent with that of a-Fe2O3, suggesting that iron in aerosol samples is mainly present in the form of a-Fe2O3. The fact that the coordination number in the second subshell is smaller than that of a-Fe2O3 might be an indication that there is a small amount of FeO mixed with a-Fe2O3 in aerosol particles. Existence of FeO is confirmed by a later XRD experiment.

  13. THE STATE OF MANGANESE IN THE PHOTOSYNTHETIC APPARATUS. I. EXAFS STUDIES ON CHLOROPLASTS AND di-u-oxo BRIDGED di-MANGANESE MODEL COMPOUNDS

    Energy Technology Data Exchange (ETDEWEB)

    Kirby, J. A.; Robertson, A. S.; Smith, J. P.; Thompson, A. C.; Thompson, A. C.; Klein, M. P.

    1980-11-01

    Extended X-ray Absorption Fine Structure (EXAFS) studies on the manganese contained in spinach chloroplasts and on certain di-u-oxo bridged manganese dimers of the form (X{sub 2}Mn)O{sub 2}(MnX{sub 2} (X=2,2'-bypyridine and 1,10-phenanthroline) are reported. From these studies, the manganese associated with photosynthetic oxygen evolution is suggested to occur as a bridged transition metal dimer with most likely another manganese. Extensive details on the analysis are included.

  14. Radiopharmaceutical scanning agents

    International Nuclear Information System (INIS)

    1976-01-01

    This invention is directed to dispersions useful in preparing radiopharmaceutical scanning agents, to technetium labelled dispersions, to methods for preparing such dispersions and to their use as scanning agents

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Scan and Uptake Thyroid scan and uptake uses small amounts of radioactive materials called radiotracers, a special ... is a branch of medical imaging that uses small amounts of radioactive material to diagnose and determine ...

  16. Nuclear Heart Scan

    Science.gov (United States)

    ... Home / Nuclear Heart Scan Nuclear Heart Scan Also known as Nuclear Stress Test , ... Learn More Connect With Us Contact Us Directly Policies Privacy Policy Freedom of Information Act (FOIA) Accessibility ...

  17. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Most thyroid scan and thyroid uptake ... you otherwise, you may resume your normal activities after your nuclear medicine scan. If any special instructions ...

  18. RBC nuclear scan

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  19. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  20. Characterization of electron beam deposited thin films of HfO2 and binary thin films of (HfO2:SiO2) by XRD and EXAFS measurements

    International Nuclear Information System (INIS)

    Das, N.C.; Sahoo, N.K.; Bhattacharyya, D.; Thakur, S.; Kamble, N.M.; Nanda, D.; Hazra, S.; Bal, J.K.; Lee, J.F.; Tai, Y.L.; Hsieh, C.A.

    2009-10-01

    In this report, we have discussed the microstructure and the local structure of composite thin films having varying hafnia and silica compositions and prepared by reactive electron beam evaporation. XRD and EXAFS studies have confirmed that the pure hafnium oxide thin film has crystalline microstructure whereas the films with finite hafnia and silica composition are amorphous. The result of EXAFS analysis has shown that the bond lengths as well as coordination numbers around hafnium atom change with the variation of hafnia and silica compositions in the thin film. Finally, change of bond lengths has been correlated with change of refractive index and band gap of the composite thin films. (author)

  1. EX6AFS: A data acquisition system for high-speed dispersive EXAFS measurements implemented using object-oriented programming techniques

    International Nuclear Information System (INIS)

    Jennings, G.; Lee, P.L.

    1995-01-01

    In this paper we describe the design and implementation of a computerized data-acquisition system for high-speed energy-dispersive EXAFS experiments on the X6A beamline at the National Synchrotron Light Source. The acquisition system drives the stepper motors used to move the components of the experimental setup and controls the readout of the EXAFS spectra. The system runs on a Macintosh IIfx computer and is written entirely in the object-oriented language C++. Large segments of the system are implemented by means of commercial class libraries, specifically the MacApp application framework from Apple, the Rogue Wave class library, and the Hierarchical Data Format datafile format library from the National Center for Supercomputing Applications. This reduces the amount of code that must be written and enhances reliability. The system makes use of several advanced features of C++: Multiple inheritance allows the code to be decomposed into independent software components and the use of exception handling allows the system to be much more reliable in the event of unexpected errors. Object-oriented techniques allow the program to be extended easily as new requirements develop. All sections of the program related to a particular concept are located in a small set of source files. The program will also be used as a prototype for future software development plans for the Basic Energy Science Synchrotron Radiation Center Collaborative Access Team beamlines being designed and built at the Advanced Photon Source

  2. Structural and thermal investigations of an amorphous GaSe9 alloy using EXAFS, cumulant expansion, and reverse Monte Carlo simulations

    International Nuclear Information System (INIS)

    Siqueira, M. C.; Maia, R. N. A.; Araujo, R. M. T.; Machado, K. D.; Stolf, S. F.

    2015-01-01

    In this article, we investigated structural and thermal properties of an amorphous alloy of the Ga–Se system. The amorphous GaSe 9 alloy was produced by mechanical alloying and it was studied using EXAFS spectroscopy and cumulant expansion method. We also made reverse Monte Carlo simulations using the total structure factor S(K) obtained from x-ray diffraction and the EXAFS χ(k) oscillations on Se and Ga K edges as input data. Several parameters, such as average coordination numbers and interatomic distances, structural and thermal disorders, asymmetry of the partial distribution functions g ij (r), and Einstein and Debye temperatures, were determined. The g ij E (r) functions were reconstructed from the cumulants C 1 , C 2 , and C 3 obtained from the Einstein model, and they were compared to the g ij RMC (r) functions obtained from the simulations. The simulations also furnished the partial bond angle distribution functions Θ ijℓ (cosθ), which describe the angular distribution of bonds between first neighbors, and give information about the kind of structural units present in the alloy

  3. Structure of a Rh/TiO2 catalyst in the strong metal-support interaction state as determined by EXAFS

    International Nuclear Information System (INIS)

    Koningsberger, D.C.; Martens, J.H.A.; Prins, R.; Short, D.R.; Sayers, D.E.

    1986-01-01

    Reduction of a highly dispersed 2.85 wt% Rh/TiO 2 catalyst at 473 K after previous calcination at 623 K resulted in EXAFS whose primary contributions are due to nearest rhodium (average coordination number of 3.1 and distance of 2.67 A) and oxygen neighbors (coordination 2.5 and distance 2.71 A). These oxygen neighbors originated at the metal-support interface. The average rhodium-rhodium coordination number did not change in the SMSI state produced by reducing the catalyst at 673 K. However, the average coordination distance contracted by 0.04 A with an accompanying decrease of the Debye-Waller factor of the Rh-Rh bond of 0.0012 A 2 . This is due to the fact that in the SMSI state the surface of the metal particles is not covered with chemisorbed hydrogen. The SMSI state leads to a structural reorganization of the support in the vicinity of the rhodium metal particles. This can be concluded from the appearance of a Rh-Ti bond at 3.42 A in the SMSI state coupled with the fact that the average coordination number of the rhodium-support oxygen bonds does not increase. Other types of rhodium-oxygen bonds could not be detected with EXAFS in this state. Thus, these results provide no evidence for coverage of the metal particle by a suboxide of TiO 2 in the SMSI state

  4. Alternative difference analysis scheme combining R-space EXAFS fit with global optimization XANES fit for X-ray transient absorption spectroscopy.

    Science.gov (United States)

    Zhan, Fei; Tao, Ye; Zhao, Haifeng

    2017-07-01

    Time-resolved X-ray absorption spectroscopy (TR-XAS), based on the laser-pump/X-ray-probe method, is powerful in capturing the change of the geometrical and electronic structure of the absorbing atom upon excitation. TR-XAS data analysis is generally performed on the laser-on minus laser-off difference spectrum. Here, a new analysis scheme is presented for the TR-XAS difference fitting in both the extended X-ray absorption fine-structure (EXAFS) and the X-ray absorption near-edge structure (XANES) regions. R-space EXAFS difference fitting could quickly provide the main quantitative structure change of the first shell. The XANES fitting part introduces a global non-derivative optimization algorithm and optimizes the local structure change in a flexible way where both the core XAS calculation package and the search method in the fitting shell are changeable. The scheme was applied to the TR-XAS difference analysis of Fe(phen) 3 spin crossover complex and yielded reliable distance change and excitation population.

  5. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  6. Scanning of bone metastases

    International Nuclear Information System (INIS)

    Robillard, J.

    1977-01-01

    The Centers against cancer of Caen, Angers, Montpellier, Strasbourg and 'the Curie Foundation' have confronted their experience in detection of bone metastases by total body scanning. From the investigation by this procedure, of 1,467 patients with cancer, it results: the confrontation between radio and scanning shows a rate of false positive and false negative identical to the literature ones; the countage scanning allows to reduce the number of false positive; scanning allows to direct bone biopsy and to improve efficiency of histological examination [fr

  7. Evidence of a splitting of the Mn-O distance and of a large lattice disorder in the charge-ordered phase of LiMn2O4 obtained by EXAFS

    International Nuclear Information System (INIS)

    Paolone, A.; Castellano, C.; Cantelli, R.; Rousse, G.; Masquelier, C.

    2003-01-01

    We measured the extended x-ray-absorption fine-structure (EXAFS) spectrum of LiMn 2 O 4 below room temperature in the charge-ordered phase and for comparison at room temperature in the cubic phase. By means of a standard fit procedure we verified that, as reported by neutron-scattering experiments, also at the local level there are two different Mn-O distances below room temperature, which correspond to the surroundings of well-defined Mn 3+ and Mn 4+ ions. This result is different from the ones obtained from previous EXAFS measurements and confirms the physical picture of the phase transition caused by the ordering of charges in contrast to a cooperative Jahn-Teller phenomenon. Moreover a large lattice disorder in the charge-ordered state, which determines a significant static contribution to the EXAFS Debye-Waller factor, has been found. This last result can be considered as the EXAFS spectral mark of charge-order transitions, even in those materials in which there is no clear evidence of the splitting of bond lengths

  8. Interaction of Zn(II) with hematite nanoparticles and microparticles: Part 2. ATR-FTIR and EXAFS study of the aqueous Zn(II)/oxalate/hematite ternary system.

    Science.gov (United States)

    Ha, Juyoung; Trainor, Thomas P; Farges, François; Brown, Gordon E

    2009-05-19

    Sorption of Zn(II) to hematite nanoparticles (HN) (av diam=10.5 nm) and microparticles (HM) (av diam=550 nm) was studied in the presence of oxalate anions (Ox2-(aq)) in aqueous solutions as a function of total Zn(II)(aq) to total Ox2-(aq) concentration ratio (R=[Zn(II)(aq)]tot/[Ox2-(aq)]tot) at pH 5.5. Zn(II) uptake is similar in extent for both the Zn(II)/Ox/HN and Zn(II)/Ox/HM ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)](tot)system than for the Zn(II)/Ox/HM ternary and the Zn(II)/HN and Zn(II)/HM binary systems at [Zn(II)(aq)]tot>4 mM. In contrast, Zn(II) uptake for the Zn(II)/HM binary system is a factor of 2 greater than that for the Zn(II)/Ox/HM and Zn(II)/Ox/HN ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)]totternary system at both R values examined (0.16 and 0.68), attenuated total reflectance Fourier transform infrared (ATR-FTIR) results are consistent with the presence of inner-sphere oxalate complexes and outer-sphere ZnOx(aq) complexes, and/or type A ternary complexes. In addition, extended X-ray absorption fine structure (EXAFS) spectroscopic results suggest that type A ternary surface complexes (i.e., >O2-Zn-Ox) are present. In the Zn(II)/Ox/HN ternary system at R=0.15, ATR-FTIR results indicate the presence of inner-sphere oxalate and outer-sphere ZnOx(aq) complexes; the EXAFS results provide no evidence for inner-sphere Zn(II) complexes or type A ternary complexes. In contrast, ATR-FTIR results for the Zn/Ox/HN sample with R = 0.68 are consistent with a ZnOx(s)-like surface precipitate and possibly type B ternary surface complexes (i.e., >O2-Ox-Zn). EXAFS results are also consistent with the presence of ZnOx(s)-like precipitates. We ascribe the observed increase of Zn(II)(aq) uptake in the Zn(II)/Ox/HN ternary system at [Zn(II)(aq)]tot>or=4 mM relative to the Zn(II)/Ox/HM ternary system to formation of a ZnOx(s)-like precipitate at the hematite nanoparticle/water interface.

  9. Model PET Scan Activity

    Science.gov (United States)

    Strunk, Amber; Gazdovich, Jennifer; Redouté, Oriane; Reverte, Juan Manuel; Shelley, Samantha; Todorova, Vesela

    2018-05-01

    This paper provides a brief introduction to antimatter and how it, along with other modern physics topics, is utilized in positron emission tomography (PET) scans. It further describes a hands-on activity for students to help them gain an understanding of how PET scans assist in detecting cancer. Modern physics topics provide an exciting way to introduce students to current applications of physics.

  10. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  11. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ...

  12. Transverse section scanning mechanism

    International Nuclear Information System (INIS)

    Doherty, E.J.

    1978-01-01

    Apparatus is described for scanning a transverse, radionuclide scan-field using an array of focussed collimators. The collimators are movable tangentially on rails, driven by a single motor via a coupled screw. The collimators are also movable in a radial direction on rails driven by a step motor via coupled screws and bevel gears. Adjacent bevel gears rotate in opposite directions so adjacent collimators move in radially opposite directions. In use, the focal point of each collimator scans at least half of the scan-field, e.g. a human head located in the central aperture, and the electrical outputs of detectors associated with each collimator are used to determine the distribution of radioactive emission intensity at a number of points in the scan-field. (author)

  13. LIDAR COMBINED SCANNING UNIT

    Directory of Open Access Journals (Sweden)

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  14. X-ray diffraction, XAFS and scanning electron microscopy study of otolith of a crevalle jack fish (caranx hippos)

    Energy Technology Data Exchange (ETDEWEB)

    Pattanaik, Sidhartha [Bailey Hall 703, Illinois Institute of Technology, 3101 S. Wabash Avenue, Chicago, IL 60616 (United States)]. E-mail: sidpattanaik@yahoo.com

    2005-04-01

    The otolith of a crevalle jack fish (caranx hippos) has been investigated by means of X-ray diffraction, X-ray absorption fine structure spectroscopy and scanning electron microscopy techniques. The results suggest that the biomineralization of otolith occurs predominantly in the aragonite phase. A detailed X-ray Rietveld analysis showed that the first shell Ca-O distances in otolith lay in the range 2.371-2.652 A, with each calcium atom coordinated to 9 oxygen atoms. While the average Ca-O distance remains same in both otolith and aragonite, certain Ca-O distances in otolith differ markedly from those in aragonite. Such difference reflects the remarkable degree of control that the protein matrix exercised over packing of calcium and carbonate ions to promote growth of rarer aragonite otolith. In view of the complex coordination chemistry of calcium in otoliths, the EXAFS analysis was limited to obtaining local atomic environment about calcium up to the first Ca-O shell. EXAFS data showed an asymmetric distribution of Ca-O bond distances with the centroid of distribution at 2.48 A, which is closer to the average Ca-O distance in aragonite than in calcite. The asymmetry in the Ca-O peak is consistent with an apparent departure of Ca-O distances from a near regular distribution, as expected of an aragonite otolith.

  15. X-ray diffraction, XAFS and scanning electron microscopy study of otolith of a crevalle jack fish (caranx hippos)

    International Nuclear Information System (INIS)

    Pattanaik, Sidhartha

    2005-01-01

    The otolith of a crevalle jack fish (caranx hippos) has been investigated by means of X-ray diffraction, X-ray absorption fine structure spectroscopy and scanning electron microscopy techniques. The results suggest that the biomineralization of otolith occurs predominantly in the aragonite phase. A detailed X-ray Rietveld analysis showed that the first shell Ca-O distances in otolith lay in the range 2.371-2.652 A, with each calcium atom coordinated to 9 oxygen atoms. While the average Ca-O distance remains same in both otolith and aragonite, certain Ca-O distances in otolith differ markedly from those in aragonite. Such difference reflects the remarkable degree of control that the protein matrix exercised over packing of calcium and carbonate ions to promote growth of rarer aragonite otolith. In view of the complex coordination chemistry of calcium in otoliths, the EXAFS analysis was limited to obtaining local atomic environment about calcium up to the first Ca-O shell. EXAFS data showed an asymmetric distribution of Ca-O bond distances with the centroid of distribution at 2.48 A, which is closer to the average Ca-O distance in aragonite than in calcite. The asymmetry in the Ca-O peak is consistent with an apparent departure of Ca-O distances from a near regular distribution, as expected of an aragonite otolith

  16. Angle and Polarization Dependent Fluorescence EXAFS Measurements on Al-doped Single Crystal V_2O3 Above and Below the Transition Temperature

    Science.gov (United States)

    Müller, O.; Pfalzer, P.; Schramme, M.; Urbach, J.-P.; Klemm, M.; Horn, S.; Frenkel, A. I.; Denboer, M. L.

    1998-03-01

    We present angle and polarisation dependent flourescence EXAFS measured on Al-doped single crystal V_2O3 below and above the structural phase transition from monoclinic to trigonal. Strong self-absorption distorted the spectra; this was corrected by using the procedure described by Tröger et al. (L. Tröger, D. Arvantis, K. Baberschke, H. Michaelis, U. Grimm, and E. Zschech, Phys. Rev. B,.46), 3238 (1992), generalized to the Lytle detector employed in our work. The spectra show pronounced dependence on the angle between the threefold symmetry axes and the polarization of the incident photons, making it possible to measure the local atomic distances in different directions. We compare our results with the measurements of Frenkel et al. (A. I. Frenkel, E. A. Stern, and F. A. Chudnovsky, Sol. State Comm.102), 637 (1997) on pure V_2O3 They found that locally the monoclinic distortion persists in the trigonal metallic phase.

  17. Magnetic properties and EXAFS study of nanocrystalline Fe2Mn0.5Cu0.5Al synthesized using mechanical alloying technique

    International Nuclear Information System (INIS)

    Nanto, Dwi; Yang, Dong-Seok; Yu, Seong-Cho

    2014-01-01

    Nanocrystalline Fe 2 Mn 0.5 Cu 0.5 Al has been synthesized by the mechanical alloying technique and studied as a function of milling time. Alloy nature of Fe 2 Mn 0.5 Cu 0.5 Al was observed in a sample milled for 96 h. The magnetic saturation is 4.0 μ B /f.u., which coincidently follows Slater–Pauling rule at 5 K. Nanocrystalline Fe 2 Mn 0.5 Cu 0.5 Al has enhanced saturate magnetization compared to any other fabrication of Fe 2 MnAl reported. Cu element plays an important role in site competes with other elements and may result in the enhancement of saturate magnetization. In accordance to the magnetic results and EXAFS pattern, it was revealed that the dynamics of magnetic properties were confirmed as structural changes of nanocrystalline Fe 2 Mn 0.5 Cu 0.5 Al

  18. Laser Scanning in Forests

    Directory of Open Access Journals (Sweden)

    Håkan Olsson

    2012-09-01

    Full Text Available The introduction of Airborne Laser Scanning (ALS to forests has been revolutionary during the last decade. This development was facilitated by combining earlier ranging lidar discoveries [1–5], with experience obtained from full-waveform ranging radar [6,7] to new airborne laser scanning systems which had components such as a GNSS receiver (Global Navigation Satellite System, IMU (Inertial Measurement Unit and a scanning mechanism. Since the first commercial ALS in 1994, new ALS-based forest inventory approaches have been reported feasible for operational activities [8–12]. ALS is currently operationally applied for stand level forest inventories, for example, in Nordic countries. In Finland alone, the adoption of ALS for forest data collection has led to an annual savings of around 20 M€/year, and the work is mainly done by companies instead of governmental organizations. In spite of the long implementation times and there being a limited tradition of making changes in the forest sector, laser scanning was commercially and operationally applied after about only one decade of research. When analyzing high-ranked journal papers from ISI Web of Science, the topic of laser scanning of forests has been the driving force for the whole laser scanning research society over the last decade. Thus, the topic “laser scanning in forests” has provided a significant industrial, societal and scientific impact. [...

  19. Bone scan in pediatrics

    International Nuclear Information System (INIS)

    Gordon, I.; Peters, A.M.

    1987-01-01

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99m Tc diphosphonate (MDP); other isotopes used include 99m Tc colloid for bone marrow scans and 67 Ga citrate and 111 In white blood cells ( 111 In WBC) for investigation of inflammatory/infective lesions

  20. Bimetallic Catalysts and Platinum Surfaces Studied by X-ray Absorption Spectroscopy and Scanning Tunnelling Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Roenning, Magnus

    2000-07-01

    Bimetallic catalyst systems used in Fischer-Tropsch synthesis (Co-Re/Al{sub 2}O{sub 3}) and in the naphtha reforming process (Pt-Re/Al{sub 2}O{sub 3}) have been studied in situ using X-ray absorption spectroscopy (EXAFS). Additionally, the adsorption of ethene on platinum single crystal surfaces has been investigated using scanning tunnelling microscopy. In situ EXAFS at the cobalt K absorption edge have been carried out at 450{sup o}C on the hydrogen reduction of a rhenium-promoted Co{sub 3}O{sub 4}/Al{sub 2}O{sub 3} catalyst. Reductions carried out using 100% hydrogen and 5% hydrogen in helium gave different results. Whereas the reduction using dilute hydrogen leads to bulk-like metallic cobalt particles (hcp or fcc), reaction with pure hydrogen yields a more dispersed system with smaller cobalt metal particles (< 40 A). The results are rationalised in terms of different degrees of reoxidation of cobalt by the higher and lower concentrations of water generated during the reduction of cobalt oxide by 100% and 5% hydrogen, respectively. Additionally, in both reduction protocols a small fraction (3 -4 wt%) of the cobalt content is randomly dispersed over the tetrahedral vacancies of the alumina support. This dispersion occurs during reduction and not calcination. The cobalt in these sites cannot be reduced at 450 {sup o}C. The local environments about the rhenium atoms in Co-Re/{gamma}-A1{sub 2}O{sub 3} catalyst after different reduction periods have been studied by X-ray absorption spectroscopy. A bimetallic catalyst containing 4.6 wt% cobalt and 2 wt% rhenium has been compared with a corresponding monometallic sample with 2 wt% rhenium on the same support. The rhenium L{sub III} EXAFS analysis shows that bimetallic particles are formed after reduction at 450{sup o}C with the average particle size being 10-15 A. Rhenium is shown to be reduced at a later stage than cobalt. The fraction of cobalt atoms entering the support obstructs the access to the support for the

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine ( ... for each thyroid uptake is five minutes or less. top of page What will I experience during ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... evaluate changes in the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should ... such as an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the ...

  3. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... abnormal was found, and should not be a cause of concern for you. If you had an ... abnormal was found, and should not be a cause of concern for you. Actual scanning time for ...

  4. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  5. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  6. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  7. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  8. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... which are encased in metal and plastic and most often shaped like a box, attached to a ... will I experience during and after the procedure? Most thyroid scan and thyroid uptake procedures are painless. ...

  9. Heart CT scan

    Science.gov (United States)

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... eat for several hours before your exam because eating can affect the accuracy of the uptake measurement. ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information ...

  11. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) is ... thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that uses ...

  12. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... that help physicians diagnose and evaluate medical conditions. These imaging scans use radioactive materials called radiopharmaceuticals or ... or had thyroid cancer. A physician may perform these imaging tests to: determine if the gland is ...

  13. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Because nuclear medicine procedures are able to pinpoint molecular activity within the body, they offer the potential ... or imaging device that produces pictures and provides molecular information. The thyroid scan and thyroid uptake provide ...

  14. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Actual scanning time for each thyroid uptake is five minutes or less. top of page What will ... diagnostic procedures have been used for more than five decades, and there are no known long-term ...

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Scan and Uptake Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  16. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information needed to make a diagnosis or to determine appropriate treatment, if any. Nuclear medicine is less expensive and ...

  17. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gamma camera and single-photon emission-computed tomography (SPECT). The gamma camera, also called a scintillation ... high as with other imaging techniques, such as CT or MRI. However, nuclear medicine scans are more ...

  18. Scanning Auger Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — A JEOL model 7830F field emission source, scanning Auger microscope.Specifications / Capabilities:Ultra-high vacuum (UHV), electron gun range from 0.1 kV to 25 kV,...

  19. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... as an overactive thyroid gland, a condition called hyperthyroidism , cancer or other growths assess the nature of ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two ...

  20. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... painless. However, during the thyroid scan, you may feel uncomfortable when lying completely still with your head ... When the radiotracer is given intravenously, you will feel a slight pin prick when the needle is ...

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... energy. top of page What are some common uses of the procedure? The thyroid scan is used ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is ... computer, create pictures offering details on both the structure and function of organs and tissues in your ...

  3. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... found, and should not be a cause of concern for you. If you had an intravenous line ... found, and should not be a cause of concern for you. Actual scanning time for each thyroid ...

  4. Body CT (CAT Scan)

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... You will receive specific instructions based on the type of scan you are undergoing. top of page ...

  6. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Uptake? A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) ... of thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that ...

  7. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  8. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... exam of any medications you are taking, including vitamins and herbal supplements. You should also inform them ... of scan you are undergoing. top of page What does the equipment look like? The special camera ...

  9. The Scanning Optical Microscope.

    Science.gov (United States)

    Sheppard, C. J. R.

    1978-01-01

    Describes the principle of the scanning optical microscope and explains its advantages over the conventional microscope in the improvement of resolution and contrast, as well as the possibility of producing a picture from optical harmonies generated within the specimen.

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... but is often performed on hospitalized patients as well. Thyroid Scan You will be positioned on an ...

  11. P-EXAFS investigations of Zn uptake by montmorillonite. The strong and weak sites concept in the 2SPNE SC/CE sorption model

    International Nuclear Information System (INIS)

    Daehn, R.; Baeyens, B.; Bradbury, M.H.

    2012-01-01

    Document available in extended abstract form only. The sorption of radioactive elements on the immobile components in the near- and far-fields of a deep geological radioactive waste repository is a significant process in retarding their aqueous phase transport and an important component in safety assessment studies. The development of robust and well-founded mechanistic sorption models to predict the uptake of radionuclides under different geochemical conditions would enhance the justification and defensibility of the sorption values used in safety studies and thereby represent a considerable contribution to the scientific basis for radioactive waste disposal. The 2 site proto-lysis non electrostatic surface complexation and cation exchange (2SPNE SC/CE) sorption model has been used over the past decade or so to quantitatively describe the uptake of metals with oxidation states from II to VI on 2:1 clay minerals; montmorillonite and illite (Bradbury and Baeyens, 1997). One of the main features in this model is that there are two broad categories of amphoteric edge sorption sites; the so called strong (≡SSOH) and weak (≡SW1OH) sites. Because of their different sorption characteristics, it was expected that the coordination environments of the surface complexes on the two site types would be different. Although the 2SPNE SC/CE model uses different mechanistic uptake processes to describe sorption, it can only be described as a 'quasi mechanistic' model because the exact nature of the surface binding sites and surface complexes is not known. In order to check the 'strong site / weak site' sorption sites hypothesis in the 2SPNE SC/CE sorption model, it was essential to perform polarised extended X-ray absorption fine structure (P-EXAFS) measurements on an uptake system, in which it was possible to obtain good spectra particularly at the low metal loadings (∼2 mmol kg-1 or less) corresponding to occupancies dominated by strong sites. The Zn-montmorillonite system

  12. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  13. Frequency scanning microstrip antennas

    DEFF Research Database (Denmark)

    Danielsen, Magnus; Jørgensen, Rolf

    1979-01-01

    The principles of using radiating microstrip resonators as elements in a frequency scanning antenna array are described. The resonators are cascade-coupled. This gives a scan of the main lobe due to the phase-shift in the resonator in addition to that created by the transmission line phase......-shift. Experimental results inX-band, in good agreement with the theory, show that it is possible to scan the main lobe an angle ofpm30degby a variation of the frequencypm300MHz, and where the 3 dB beamwidth is less than10deg. The directivity was 14.7 dB, while the gain was 8.1 dB. The efficiency might be improved...

  14. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  15. Scanning the phenomenological MSSM

    CERN Document Server

    Wuerzinger, Jonas

    2017-01-01

    A framework to perform scans in the 19-dimensional phenomenological MSSM is developed and used to re-evaluate the ATLAS experiments' sensitivity to R-parity-conserving supersymmetry with LHC Run 2 data ($\\sqrt{s}=13$ TeV), using results from 14 separate ATLAS searches. We perform a $\\tilde{t}_1$ dedicated scan, only considering models with $m_{\\tilde{t}_1}<1$ TeV, while allowing both a neutralino ($\\tilde{\\chi}_1^0$) and a sneutrino ($\\tilde{\

  16. Calibration of scanning Lidar

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Courtney, Michael

    This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast. Additio......This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast...

  17. Adaptive Optical Scanning Holography

    Science.gov (United States)

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-01-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably. PMID:26916866

  18. Binuclear Pt-Tl bonded complex with square pyramidal coordination around Pt: a combined multinuclear NMR, EXAFS, UV-Vis, and DFT/TDDFT study in dimethylsulfoxide solution.

    Science.gov (United States)

    Purgel, Mihály; Maliarik, Mikhail; Glaser, Julius; Platas-Iglesias, Carlos; Persson, Ingmar; Tóth, Imre

    2011-07-04

    The structure and bonding of a new Pt-Tl bonded complex formed in dimethylsulfoxide (dmso), (CN)(4)Pt-Tl(dmso)(5)(+), have been studied by multinuclear NMR and UV-vis spectroscopies, and EXAFS measurements in combination with density functional theory (DFT) and time dependent density functional theory (TDDFT) calculations. This complex is formed following the equilibrium reaction Pt(CN)(4)(2-) + Tl(dmso)(6)(3+) ⇆ (CN)(4)Pt-Tl(dmso)(5)(+) + dmso. The stability constant of the Pt-Tl bonded species, as determined using (13)C NMR spectroscopy, amounts to log K = 2.9 ± 0.2. The (NC)(4)Pt-Tl(dmso)(5)(+) species constitutes the first example of a Pt-Tl bonded cyanide complex in which the sixth coordination position around Pt (in trans with respect to the Tl atom) is not occupied. The spectral parameters confirm the formation of the metal-metal bond, but differ substantially from those measured earlier in aqueous solution for complexes (CN)(5)Pt-Tl(CN)(n)(H(2)O)(x)(n-) (n = 0-3). The (205) Tl NMR chemical shift, δ = 75 ppm, is at extraordinary high field, while spin-spin coupling constant, (1)J(Pt-Tl) = 93 kHz, is the largest measured to date for a Pt-Tl bond in the absence of supporting bridging ligands. The absorption spectrum is dominated by two strong absorption bands in the UV region that are assigned to MMCT (Pt → Tl) and LMCT (dmso → Tl) bands, respectively, on the basis of MO and TDDFT calculations. The solution of the complex has a bright yellow color as a result of a shoulder present on the low energy side of the band at 355 nm. The geometry of the (CN)(4)Pt-Tl core can be elucidated from NMR data, but the particular stoichiometry and structure involving the dmso ligands are established by using Tl and Pt L(III)-edge EXAFS measurements. The Pt-Tl bond distance is 2.67(1) Å, the Tl-O bond distance is 2.282(6) Å, and the Pt-C-N entity is linear with Pt-C and Pt···N distances amounting to 1.969(6) and 3.096(6) Å, respectively. Geometry optimizations on

  19. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... process that regulates the rate at which the body converts food to energy. top of page What are some common uses of the procedure? The thyroid scan is used to determine the size, shape and position of the thyroid gland. The ...

  20. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake ...

  1. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  2. Scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cox, B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1970-05-15

    The JSM-11 scanning electron microscope at CRNL has been used extensively for topographical studies of oxidized metals, fracture surfaces, entomological and biological specimens. A non-dispersive X-ray attachment permits the microanalysis of the surface features. Techniques for the production of electron channeling patterns have been developed. (author)

  3. Scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Binnig, G.; Rohrer, H.

    1983-01-01

    Based on vacuum tunneling, a novel type of microscope, the scanning tunneling microscope (STM) was developed. It has an unprecedented resolution in real space on an atomic scale. The authors review the important technical features, illustrate the power of the STM for surface topographies and discuss its potential in other areas of science and technology. (Auth.)

  4. Bone scan in rheumatology

    International Nuclear Information System (INIS)

    Morales G, R.; Cano P, R.; Mendoza P, R.

    1993-01-01

    In this chapter a revision is made concerning different uses of bone scan in rheumatic diseases. These include reflex sympathetic dystrophy, osteomyelitis, spondyloarthropaties, metabolic bone diseases, avascular bone necrosis and bone injuries due to sports. There is as well some comments concerning pediatric pathology and orthopedics. (authors). 19 refs., 9 figs

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... information. The thyroid scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is a gland in the neck that controls metabolism , a chemical process that regulates the rate at which the body ...

  6. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  7. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  8. Scanning electron microscope

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The principle underlying the design of the scanning electron microscope (SEM), the design and functioning of SEM are described. Its applications in the areas of microcircuitry and materials science are outlined. The development of SEM in India is reviewed. (M.G.B.)

  9. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... you: have had any tests, such as an x-ray or CT scan, surgeries or treatments using iodinated ... page How does the procedure work? With ordinary x-ray examinations, an image is made by passing x- ...

  11. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine (I-123 or I-131) in liquid or capsule form to swallow. The thyroid uptake will begin several hours to 24 hours later. Often, two separate uptake ...

  12. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two months. are taking medications or ingesting other substances that contain iodine , including kelp, seaweed, cough syrups, multivitamins or heart medications. have any ...

  13. Scanning probe microscopy

    International Nuclear Information System (INIS)

    Mainsbridge, B.

    1994-01-01

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, 'because we are too big'. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs

  14. Scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Mainsbridge, B [Murdoch Univ., WA (Australia). School of Mathematical and Physical Sciences

    1994-12-31

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, `because we are too big`. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs.

  15. 67Ga lung scan

    International Nuclear Information System (INIS)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-01-01

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate 67 Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the 67 Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of 67 Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of 67 Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography

  16. Horizon Scanning for Pharmaceuticals

    DEFF Research Database (Denmark)

    Lepage-Nefkens, Isabelle; Douw, Karla; Mantjes, GertJan

    for a joint horizon scanning system (HSS).  We propose to create a central “horizon scanning unit” to perform the joint HS activities (a newly established unit, an existing HS unit, or a third party commissioned and financed by the collaborating countries). The unit will be responsible for the identification...... and filtration of new and emerging pharmaceutical products. It will maintain and update the HS database, organise company pipeline meetings, and disseminate the HSS’s outputs.  The HS unit works closely together with the designated national HS experts in each collaborating country. The national HS experts...... will collect country-specific information, liaise between the central HS unit and country-specific clinical and other experts, coordinate the national prioritization process (to select products for early assessment), and communicate the output of the HSS to national decision makers.  The outputs of the joint...

  17. Multichannel scanning spectrophotometer

    International Nuclear Information System (INIS)

    Lagutin, A.F.

    1979-01-01

    A spectrophotometer designed in the Crimea astrophysical observatory is described. The spectrophotometer is intended for the installation at the telescope to measure energy distribution in the star spectra in the 3100-8550 A range. The device is made according to the scheme with a fixed diffraction lattice. The choice of the optical kinematic scheme is explained. The main design elements are shown. Some singularities of the scanning drive kinematics are considered. The device performance is given

  18. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John

    2017-05-09

    Electrochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  19. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John M.; Shinde, Aniketa A.; Guevarra, Dan W.; Jones, Ryan J.; Marcin, Martin R.; Mitrovic, Slobodan

    2017-05-09

    Electrochemical or electrochemical and photochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  20. IMEF gamma scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

  1. IMEF gamma scanning system

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum.

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs

  2. Scanning unit for collectrons

    International Nuclear Information System (INIS)

    Plaige, Yves.

    1976-01-01

    This invention concerns a measurement scanning assembly for collectron type detectors. It is used in measuring the neutron flux in nuclear reactors. As the number of these detectors in a reactor can be very great, they are not usually all connected permanently to the measuring facility but rather in turn by means of a scanning device which carries out, as it were, multiplexing between all the collectrons and the input of a single measuring system. The object of the invention is a scanning assembly which is of relative simplicity through an original organisation. Specifically, according to this organisation, the collectrons outputs are grouped together in bunches, each of these bunches being processed by a multiplexing sub-assembly belonging to a first stage, the different outputs of these multiplexing subassemblies of this first stage being grouped together yet again in bunches processed by multiplexors forming a new stage and so forth. Further, this structure is specially adapted for use with collectrons by utilising a current amplifier at each multiplexing level so that from one end to the other of the multiplexing system, the commutations are carried out on currents and not on voltages [fr

  3. Forensic Scanning Electron Microscope

    Science.gov (United States)

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  4. Iron environment in ferritin with large amounts of phosphate, from Azotobacter vinelandii and horse spleen, analyzed using Extended X-ray Absorption fine Structure (EXAFS)

    International Nuclear Information System (INIS)

    Rohrer, J.S.; Islam, Q.T.; Sayes, D.E.; Theil, E.C.; Watt, G.D.

    1990-01-01

    The iron core of proteins in the ferritin family displays structural variations that includes phosphate content was well as the number and the degree of ordering of the iron atoms. Earlier studies had shown that ferritin iron cores naturally high in phosphate, e.g., Azotobacter vinelandii (AV) ferritin had decreased long-range order. Here, the influence of phosphate on the local structure around iron in ferritin cores is reported, comparing the EXAFS of AV ferritin, reconstituted ferritin and native horse spleen ferritin. In contrast, when the phosphate content was high in AV ferritin and horse spleen ferritin reconstituted with phosphate, the average iron atom had five to six phosphorus neighbors at 3.17 angstrom. Moreover, the number of detectable iron neighbors was lower when phosphate was high or present during reconstitution and the interatomic distance was longer indicating that some phosphate bridges neighboring iron atoms. However, the decrease in the number of detectable iron-iron neighbors compared to HSF and the higher number of Fe-P interactions relative to Fe-Fe interactions suggest that some phosphate ligands were chain termini, or blocked crystal growth, and/or introduced defects which contributed both to the long-range disorder and to altered redox properties previously observed in AV ferritin

  5. The double-well oscillating potential of oxygen atoms in perovskite system Ba(K)BiO sub 3 : EXAFS - analysis results

    CERN Document Server

    Menushenkov, A P; Konarev, P V; Meshkov, A A; Benazeth, S; Purans, J

    2000-01-01

    Temperature-dependent X-ray absorption investigations were made on the Bi L sub 3 -edge in Ba sub 1 sub - sub x K sub x BiO sub 3 with x=0.0, 0.4 and 0.5. For the superconducting samples (x=0.4 and 0.5) it has been found that the local structure differs from the ideal cubic in contrast to the neutron and X-ray diffraction data. The provided analysis of the EXAFS spectra indicates that the oxygen atoms move in double-well potential produced by the existence of two non-equivalent octahedral types of the oxygen environment of bismuth. The vibrations in such a potential lead to modulations of the Bi-O lengths with low frequency which is determined by the soft oxygen octahedron rotation mode frequency. This induces strong electron-phonon interaction and may be the reason for relatively high-temperature transition (T sub c approx 30 K) to the superconducting state.

  6. EXAFS analysis of cations distribution in structure of Co1-xNixFe2O4 nanoparticles obtained by hydrothermal method in aloe vera extract solution

    Science.gov (United States)

    Wongpratat, Unchista; Maensiri, Santi; Swatsitang, Ekaphan

    2016-09-01

    Effect of cations distribution upon EXAFS analysis on magnetic properties of Co1-xNixFe2O4 (x = 0, 0.25, 0.50, 0.75 and 1.0) nanoparticles prepared by the hydrothermal method in aloe vera extract solution were studied. XRD analysis confirmed a pure phase of cubic spinel ferrite of all samples. Changes in lattice parameter and particle size depended on the Ni content with partial substitution and site distributions of Co2+, Ni2+ ions of different ionic radii at both tetrahedral and octahedral sites in the crystal structure. Particle sizes of samples estimated by TEM images were found to be in the range of 10.87-62.50 nm. The VSM results at room temperature indicated the ferrimagnetic behavior of all samples. Superparamagnetic behavior was observed in NiFe2O4 sample. The coercivity (Hc) and remanance (Mr) values were related to the particle sizes of samples. The saturation magnetization (Ms) was increased by a factor of 1.4 to a value of 57.57 emu/g, whereas the coercivity (Hc) was decreased by a factor of 20 to a value of 63.15 Oe for a sample with x = 0.75. In addition to the cations distribution, the increase of aspect ratio (surface to volume ratio) due to the decrease of particle size could significantly affect the magnetic properties of the materials.

  7. Structure of the Hydrated Platinum(II) Ion And the Cis-Diammine-Platinum(II) Complex in Acidic Aqueous Solution: An EXAFS Study

    Energy Technology Data Exchange (ETDEWEB)

    Jalilehvand, F.; Laffin, L.J.

    2009-05-18

    Careful analysis of Pt L{sub 3}-edge extended X-ray absorption fine structure (EXAFS) spectra shows that the hydrated platinum(II) ion in acidic (HClO{sub 4}) aqueous solution binds four water molecules with the Pt-O bond distance 2.01(2) {angstrom} and one (or two) in the axial position at 2.39(2) {angstrom}. The weak axial water coordination is in accordance with the unexpectedly small activation volume previously reported for water exchange in an interchange mechanism with associative character. The hydrated cis-diammineplatinum(II) complex has a similar coordination environment with two ammine and two aqua ligands strongly bound with Pt-O/N bond distances of 2.01(2) {angstrom} and, in addition, one (or two) axial water molecule at 2.37(2) {angstrom}. This result provides a new basis for theoretical computational studies aiming to connect the function of the anticancer drug cis-platin to its ligand exchange reactions, where usually four-coordinated square planar platinum(II) species are considered as the reactant and product. {sup 195}Pt NMR spectroscopy has been used to characterize the Pt(II) complexes.

  8. Optical and mechanical design of the extended x-ray absorption fine structure (EXAFS) beam-line at Indus-II synchrotron source

    International Nuclear Information System (INIS)

    Das, N.C.; Jha, S.N.; Bhattacharyya, D.; Sinha, A.K.; Mishra, V.K.; Verma, Vishnu; Ghosh, A.K.

    2002-11-01

    An extended x-ray absorption fine structure (EXAFS) beam line for x-ray absorption studies using energy dispersive geometry and position sensitive detector is being designed for the INDUS-II Synchrotron source. The beam line would be used for doing x-ray absorption experiments involving measurements of fme structures above the absorption edge of different species of atoms in a material The results of the above experiments would lead to the determination of different important structural parameters of materials viz.. inter-atomic distance. co-ordination number, degree of disorder and radial distribution function etc. The optical design of the beam line has been completed based on the working principle that a single crystal bent in the shape of an ellipse by a crystal bender would act as a dispersing as well as focusing element. The mechanical design of the beam line including the crystal bender has also been completed and discussed here. Calculations have been done to detennine the temperature profile on the different components of the beam line under exposure to synchrotron radiation and proper cooling channels have been designed to bring down the heat load on the components. (author)

  9. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  10. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  11. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  12. Scanning Color Laser Microscope

    Science.gov (United States)

    Awamura, D.; Ode, T.; Yonezawa, M.

    1988-01-01

    A confocal color laser microscope which utilizes a three color laser light source (Red: He-Ne, Green: Ar, Blue: Ar) has been developed and is finding useful applications in the semiconductor field. The color laser microscope, when compared to a conventional microscope, offers superior color separation, higher resolution, and sharper contrast. Recently some new functions including a Focus Scan Memory, a Surface Profile Measurement System, a Critical Dimension Measurement system (CD) and an Optical Beam Induced Current Function (OBIC) have been developed for the color laser microscope. This paper will discuss these new features.

  13. Scanning apparatus and method

    International Nuclear Information System (INIS)

    Brunnett, C.J.

    1980-01-01

    A novel method is described for processing the analogue signals from the photomultiplier tubes in a tomographic X-ray scanner. The system produces a series of pulses whose instantaneous frequency depends on the detected intensity of the X-radiation. A timer unit is used to determine the segment scan intervals and also to deduce the average radiation intensity detected during this interval. The overall system is claimed to possess the advantageous properties of low time delay, wide bandwidth and relative low cost. (U.K.)

  14. NEW SCANNING DEVICE FOR SCANNING TUNNELING MICROSCOPE APPLICATIONS

    NARCIS (Netherlands)

    SAWATZKY, GA; Koops, Karl Richard

    A small, single piezo XYZ translator has been developed. The device has been used as a scanner for a scanning tunneling microscope and has been tested successfully in air and in UHV. Its simple design results in a rigid and compact scanning unit which permits high scanning rates.

  15. Ultrafast scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Botkin, D.A. [California Univ., Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley Lab., CA (United States)

    1995-09-01

    I have developed an ultrafast scanning tunneling microscope (USTM) based on uniting stroboscopic methods of ultrafast optics and scanned probe microscopy to obtain nanometer spatial resolution and sub-picosecond temporal resolution. USTM increases the achievable time resolution of a STM by more than 6 orders of magnitude; this should enable exploration of mesoscopic and nanometer size systems on time scales corresponding to the period or decay of fundamental excitations. USTM consists of a photoconductive switch with subpicosecond response time in series with the tip of a STM. An optical pulse from a modelocked laser activates the switch to create a gate for the tunneling current, while a second laser pulse on the sample initiates a dynamic process which affects the tunneling current. By sending a large sequence of identical pulse pairs and measuring the average tunnel current as a function of the relative time delay between the pulses in each pair, one can map the time evolution of the surface process. USTM was used to measure the broadband response of the STM`s atomic size tunnel barrier in frequencies from tens to hundreds of GHz. The USTM signal amplitude decays linearly with the tunnel junction conductance, so the spatial resolution of the time-resolved signal is comparable to that of a conventional STM. Geometrical capacitance of the junction does not appear to play an important role in the measurement, but a capacitive effect intimately related to tunneling contributes to the measured signals and may limit the ultimate resolution of the USTM.

  16. Scanning device for a spectrometer

    International Nuclear Information System (INIS)

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  17. Factors influencing bone scan quality

    International Nuclear Information System (INIS)

    Adams, F.G.; Shirley, A.W.

    1983-01-01

    A reliable subjective method of assessing bone scan quality is described. A large number of variables which theoretically could influence scan quality were submitted to regression and factor analysis. Obesity, age, sex and abnormality of scan were found to be significant but weak variables. (orig.)

  18. Effect of Fe(II)/Ce(III) dosage ratio on the structure and anion adsorptive removal of hydrothermally precipitated composites: Insights from EXAFS/XANES, XRD and FTIR

    KAUST Repository

    Chubar, Natalia

    2016-10-24

    In this work, we present material chemistry in the hydrothermal synthesis of new complex structure materials based on various dosage ratios of Fe and Ce (1:0, 2:1, 1:1, 1:2, 0:1), characterize them by the relevant methods that allow characterization of both crystalline and amorphous phases and correlate their structure/surface properties with the adsorptive performance of the five toxic anions. The applied synthesis conditions resulted in the formation of different compounds of Fe and Ce components. The Fe-component was dominated by various phases of Fe hydrous oxides, whereas the Ce-component was composed of various phases of Ce carbonates. The presence of two metal salts in raw materials resulted in the formation of a mesoporous structure and averaged the surface area compared to one metal-based material. The surface of all Fe-Ce composites was abundant in Fe component phases. Two-metal systems showed stronger anion removal performance than one-metal materials. The best adsorption was demonstrated by Fe-Ce based materials that had low crystallinity, that were rich in phases and that exhibited surfaces were abundant in greater number of surface functional groups. Notably, Fe extended fine structures simulated by EXAFS in these better adsorbents were rich from oscillations from both heavy and light atoms. This work provides new insights on the structure of composite inorganic materials useful to develop their applications in adsorption and catalysis. It also presents new inorganic anion exchangers with very high removal potential to fluoride and arsenate.

  19. Effect of Fe(II)/Ce(III) dosage ratio on the structure and anion adsorptive removal of hydrothermally precipitated composites: Insights from EXAFS/XANES, XRD and FTIR

    KAUST Repository

    Chubar, Natalia; Gerda, Vasyl; Banerjee, Dipanjan; Yablokova, Ganna

    2016-01-01

    In this work, we present material chemistry in the hydrothermal synthesis of new complex structure materials based on various dosage ratios of Fe and Ce (1:0, 2:1, 1:1, 1:2, 0:1), characterize them by the relevant methods that allow characterization of both crystalline and amorphous phases and correlate their structure/surface properties with the adsorptive performance of the five toxic anions. The applied synthesis conditions resulted in the formation of different compounds of Fe and Ce components. The Fe-component was dominated by various phases of Fe hydrous oxides, whereas the Ce-component was composed of various phases of Ce carbonates. The presence of two metal salts in raw materials resulted in the formation of a mesoporous structure and averaged the surface area compared to one metal-based material. The surface of all Fe-Ce composites was abundant in Fe component phases. Two-metal systems showed stronger anion removal performance than one-metal materials. The best adsorption was demonstrated by Fe-Ce based materials that had low crystallinity, that were rich in phases and that exhibited surfaces were abundant in greater number of surface functional groups. Notably, Fe extended fine structures simulated by EXAFS in these better adsorbents were rich from oscillations from both heavy and light atoms. This work provides new insights on the structure of composite inorganic materials useful to develop their applications in adsorption and catalysis. It also presents new inorganic anion exchangers with very high removal potential to fluoride and arsenate.

  20. Hydrous ferric oxide: evaluation of Cd-HFO surface complexation models combining Cd(K) EXAFS data, potentiometric titration results, and surface site structures identified from mineralogical knowledge.

    Science.gov (United States)

    Spadini, Lorenzo; Schindler, Paul W; Charlet, Laurent; Manceau, Alain; Vala Ragnarsdottir, K

    2003-10-01

    The surface properties of ferrihydrite were studied by combining wet chemical data, Cd(K) EXAFS data, and a surface structure and protonation model of the ferrihydrite surface. Acid-base titration experiments and Cd(II)-ferrihydrite sorption experiments were performed within 3titration data could be adequately modeled by triple bond Fe- OH(2)(+1/2)-H(+)triple bond Fe-OH(-1/2),logk((int))=-8.29, assuming the existence of a unique intrinsic microscopic constant, logk((int)), and consequently the existence of a single significant type of acid-base reactive functional groups. The surface structure model indicates that these groups are terminal water groups. The Cd(II) data were modeled assuming the existence of a single reactive site. The model fits the data set at low Cd(II) concentration and up to 50% surface coverage. At high coverage more Cd(II) ions than predicted are adsorbed, which is indicative of the existence of a second type of site of lower affinity. This agrees with the surface structure and protonation model developed, which indicates comparable concentrations of high- and low-affinity sites. The model further shows that for each class of low- and high-affinity sites there exists a variety of corresponding Cd surface complex structure, depending on the model crystal faces on which the complexes develop. Generally, high-affinity surface structures have surface coordinations of 3 and 4, as compared to 1 and 2 for low-affinity surface structures.

  1. Solvent phase characterisation of lanthanide(3) and americium(3) complexes with malonamide (tema) and ter-pyridine ligands by EXAFS: comparison with single crystals

    International Nuclear Information System (INIS)

    Den Auwer, C.; Presson, M.T.; Grigoriev, M.; Madic, C.; Nierlich, M.; Thuery, P.; David, F.; Hubert, S.; Drew, M.G.B.; Hudson, M.J.; Iveson, P.B.; Russell, M.L.

    2002-01-01

    In order to develop molecules that will be good candidates for the extractive separation of the various elements contained within nuclear fuels, 4f and 5f molecular chemistry has been the subject of numerous studies. Thus, to better understand the ligand to cation interaction and to fine tune the theoretical models, precise knowledge about the cation co-ordination sphere must be obtained. More precisely, both structural and electronic data must be acquired in order to define the role of the cation frontier orbitals within the complex. To do so, various structural probes must be used, from vibrational and nuclear techniques to X-ray spectroscopies. In the field of actinide solvent extraction, the species of interest are in the solvent phase and both solid state diffraction methods and solvent phase X-ray absorption spectroscopy have become of primary importance lately. A number of Ln(III) and Am(III) complexes of the type M(NO 3 ) 3 L 1,2 (where M is either Ln 3+ or Am 3+ and L is either the 2,2',6',2 - ter-pyridine (Tpy) or the N,N,N',N' tetraethyl-malonamide (TEMA) ligand) have been crystallographically characterised in the solid state. In order to obtain structural information in the solvent phase, EXAFS L III edge measurements have been performed on the cation (DCI ring at the LURE facility). The overall contraction (-0.05 Angstrom) of the cation co-ordination sphere from Nd 3+ to Lu 3+ reflects the decrease in the lanthanide ionic radii. With the TEMA ligand, this steric constraint generates the elongation of one nitrate bond, leading to one formally monodendate nitrate for the late Ln ions. Comparison is made with the Tpy ligand. In the case of Am 3+ cation, comparison with isostructural Nd 3+ shows that similar co-ordination spheres are obtained, either with the TEMA or the Tpy ligands. (authors)

  2. CT scans in encephalitis

    International Nuclear Information System (INIS)

    Imanishi, Masami; Morimoto, Tetsuya; Iida, Noriyuki; Hisanaga, Manabu; Kinugawa, Kazuhiko

    1980-01-01

    Generally, CT scans reveal a decrease in the volume of the ventricular system, sylvian fissures and cortical sulci in the acute stage of encephalitis, and softening of the cerebral lobes with dilatation of the lateral ventricles and subarachnoidian dilated spaces in the chronic stage. We encountered three cases of encephalitis: mumps (case 1), herpes simplex (case 2), and syphilis (case 3). In case 1, brain edema was seen in the acute stage and brain atrophy in the chronic stage. In case 2, necrosis of the temporal pole, which is pathognomonic in herpes simplex encephalitis, was recognized. And in case 3, multiple lesions whose CT appearance was enhanced by contrast materials were found scattered over the whole brain. These lesions were diagnosed as inflammatory granuloma by histological examination. (author)

  3. Scanning device for scintigraphy

    International Nuclear Information System (INIS)

    Casale, R.

    1975-01-01

    A device is described for the scintigraphic scanning according to a horizontal plane, comprising: (a) A support provided with two guides horizontally and longitudinally located, one of which is located in the upper part of the support, while the second guide is located in the lower part of the support; (b) A carriage, movable with respect to the support along the two guides, provided in its upper part, projecting above the support, with rolling means suitable to support and to cause to slide along its axis a support rod for the first detector, horizontally and transversely located, said carriage being further provided in its lower part with a recess with possible rolling means suitable to support and to cause to slide along its axis a second support rod for the second detector, said second rod being located parallel to the first rod and below it; (c) One or two support rods for the detectors, the first of said rods being supported above the support in a sliding way along its axis, by the rolling means located in the upper part of the carriage, and the second rod if present is supported slidingly along its axis by the possible rolling means contained in the suitable recess which is provided in the lower part of the carriage, and (d) A vertical shaft supported by said carriage on which is mounted a toothed wheel for each rod, each toothed wheel engaging a positive drive belt or the like, which is connected to each said rod so that rotation of the shaft determines the simultaneous displacement of the two rods along their axes; and single motor means for driving said shaft during a scanning operation. (U.S.)

  4. Scanning the periphery.

    Science.gov (United States)

    Day, George S; Schoemaker, Paul J H

    2005-11-01

    Companies often face new rivals, technologies, regulations, and other environmental changes that seem to come out of left field. How can they see these changes sooner and capitalize on them? Such changes often begin as weak signals on what the authors call the periphery, or the blurry zone at the edge of an organization's vision. As with human peripheral vision, these signals are difficult to see and interpret but can be vital to success or survival. Unfortunately, most companies lack a systematic method for determining where on the periphery they should be looking, how to interpret the weak signals they see, and how to allocate limited scanning resources. This article provides such a method-a question-based framework for helping companies scan the periphery more efficiently and effectively. The framework divides questions into three categories: learning from the past (What have been our past blind spots? What instructive analogies do other industries offer? Who in the industry is skilled at picking up weak signals and acting on them?); evaluating the present (What important signals are we rationalizing away? What are our mavericks, outliers, complainers, and defectors telling us? What are our peripheral customers and competitors really thinking?); and envisioning the future (What future surprises could really hurt or help us? What emerging technologies could change the game? Is there an unthinkable scenario that might disrupt our business?). Answering these questions is a good first step toward anticipating problems or opportunities that may appear on the business horizon. The article concludes with a self-test that companies can use to assess their need and capability for peripheral vision.

  5. GPR scan assessment

    Directory of Open Access Journals (Sweden)

    Abbas M. Abbas

    2015-06-01

    Full Text Available Mekaad Radwan monument is situated in the neighborhood of Bab Zuweila in the historical Cairo, Egypt. It was constructed at the middle XVII century (1635 AD. The building has a rectangle shape plan (13 × 6 m with the longitudinal sides approximately WNW-ESE. It comprises three storages namely; the ground floor; the opened floor (RADWAN Bench and the living floor with a total elevation of 15 m above the street level. The building suffers from severe deterioration phenomena with patterns of damage which have occurred over time. These deterioration and damages could be attributed to foundation problems, subsoil water and also to the earthquake that affected the entire Greater Cairo area in October 1992. Ground Penetrating Radar (GPR scan was accomplished against the walls of the opened floor (RADWAN Bench to evaluate the hazard impact on the walls textures and integrity. The results showed an anomalous feature through the southern wall of RADWAN Bench. A mathematical model has been simulated to confirm the obtained anomaly and the model response exhibited a good matching with the outlined anomaly.

  6. Radionuclide brain scanning

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.

    1992-01-01

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  7. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  8. Gastrointestinal scanning agent

    International Nuclear Information System (INIS)

    Francis, M.D.

    1980-01-01

    An easily prepared radiolabeled gastrointestinal scanning agent is described. Technetium-99m has ideal characteristics for imaging the upper and lower GI tract and determining stomach emptying and intestinal transit time when used with an insoluble particulate material. For example, crystalline and amorphous calcium phosphate particles can be effectively labeled in a one-step process using sup(99m)TcO 4 and SnCl 2 . These labeled particles have insignificant mass and when administered orally pass through the GI tract unchanged, without affecting the handling and density of the intestinal contents. Visualization of the esophageal entry into the stomach, the greater and lesser curvatures of the stomach, ejection into the duodenum, and rates of passage through the upper and lower GI tract are obtained. The slurry of sup(99m)TC particulate can be given rectally by enema. Good images of the cecum and the ascending, transverse, and descending colon are obtained. Mucosal folds and the splenic and hepatic flexures are visualized. The resilience of the large intestine is also readily visualized by pneumocolonographic techniques. (author)

  9. Radionuclide brain scanning

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Dayem, H

    1993-12-31

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ``allied advances`` with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  10. Hyperchromatic laser scanning cytometry

    Science.gov (United States)

    Tárnok, Attila; Mittag, Anja

    2007-02-01

    In the emerging fields of high-content and high-throughput single cell analysis for Systems Biology and Cytomics multi- and polychromatic analysis of biological specimens has become increasingly important. Combining different technologies and staining methods polychromatic analysis (i.e. using 8 or more fluorescent colors at a time) can be pushed forward to measure anything stainable in a cell, an approach termed hyperchromatic cytometry. For cytometric cell analysis microscope based Slide Based Cytometry (SBC) technologies are ideal as, unlike flow cytometry, they are non-consumptive, i.e. the analyzed sample is fixed on the slide. Based on the feature of relocation identical cells can be subsequently reanalyzed. In this manner data on the single cell level after manipulation steps can be collected. In this overview various components for hyperchromatic cytometry are demonstrated for a SBC instrument, the Laser Scanning Cytometer (Compucyte Corp., Cambridge, MA): 1) polychromatic cytometry, 2) iterative restaining (using the same fluorochrome for restaining and subsequent reanalysis), 3) differential photobleaching (differentiating fluorochromes by their different photostability), 4) photoactivation (activating fluorescent nanoparticles or photocaged dyes), and 5) photodestruction (destruction of FRET dyes). With the intelligent combination of several of these techniques hyperchromatic cytometry allows to quantify and analyze virtually all components of relevance on the identical cell. The combination of high-throughput and high-content SBC analysis with high-resolution confocal imaging allows clear verification of phenotypically distinct subpopulations of cells with structural information. The information gained per specimen is only limited by the number of available antibodies and by sterical hindrance.

  11. Study of non stoichiometric pure and Zr-Doped yttria surfaces by X-Ray photoelectron spectroscopy and scanning electron microscopy

    International Nuclear Information System (INIS)

    Gautier, M.; Duraud, J.P.; Jollet, F.; Thromat, N.; Maire, P.; Le Gressus, C.

    1988-01-01

    Surfaces of oxygen-deficient yttrium oxide, pure or Zr-doped, have been studied by means of X-ray photoelectron spectroscopy and scanning electron microscopy. The bulk local geometric structure of these non-stoichiometric compounds was previously determined around the Y atom by an EXAFS (Extended X-ray absorption fine structure) study. The local electronic structure around both Y and O, at the surface, was investigated by X-ray photoelectron spectroscopy. The partial transfer of the electronic distribution between the anion and the cation was probed using the Auger parameter. Coupling of these experiments with microscopic observations show that: - In the pure oxygen-deficient sample, the concentration of oxygen vacancies appears to be increased at the grain boundaries. - The Auger parameter shows upon reduction an evolution of the Y-O bond towards a more covalent one, this evolution being modulated with the presence of Zr0 2

  12. Gallium scans in myasthenia gravis

    International Nuclear Information System (INIS)

    Swick, H.M.; Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether 67 Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on 67 Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis

  13. Gallium scans in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Swick, H.M. (Univ. of Kentucky, Lexington); Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether /sup 67/Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on /sup 67/Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis. (HLW)

  14. The hydrolysis and precipitation of Pd(II) in 0.6 mol kg-1 NaCl: A potentiometric, spectrophotometric, and EXAFS study

    International Nuclear Information System (INIS)

    Boily, Jean-Francois F.; Seward, Terry M.; Charnock, John M.

    2007-01-01

    The hydrolysis of palladium was investigated in 0.6 mol kg -1 NaCl at 298.2 K. Potentiometric titrations of solutions at various total concentrations of palladium(II) revealed that dilute (millimolar) conditions can be used to monitor the proton release due to hydrolysis reactions up to 2 protons per palladium(II) as long as the equilibration time is kept small. Spectrophotometric titrations were used to corroborate the homogeneous changes in speciation for the PdCl 3 OH 2- species and to extract its correlative molar absorption coefficients in the 210-320 nm range. The molar absorption coefficients are similar to those of PdCl42- but exhibit a broader distribution of excitation energies resulting from the blue shift of the dominant charge transfer bands due to the presence of OH-. The longer-term potentiometric titrations systematically yielded, on the other hand, precipitates which matured over a period of 6 weeks and resulted in a more extensive release of protons to the solution. Precipitation experiments at six different total palladium(II) concentrations in the 3-11 pH range showed the dominant precipitating phase as Pd(OH)1.72Cl0.28. The coordination environment of Pd in this solid was investigated by extended X-ray absorption fine structure spectroscopy (EXAFS) and yielded an average 1.75 O and 0.25 Cl per Pd atoms with a Pd-O distance of 2.0 (angstrom) and Pd-Cl of 2.1 (angstrom). Finally, the precipitation experiments showed the final products to be of larger solubility than a literature Pd(OH)2 solubility study in which the KCl media induced a solid phase transformation to Pd(OH)1.72Cl0.28. Polynuclear complexes Pdq(OH)r2q-r with q=r=[3,9] explain the combined precipitation and hydrolysis data and may represent subsets of [Pd(OH)2]n and/or [Pd(OH)1.72Cl0.28]n chains coiled into nanometer-sized spheroids previously described in the literature

  15. Large Scale Scanning Probe Microscope "Making Shear Force Scanning visible."

    NARCIS (Netherlands)

    Bosma, E.; Offerhaus, Herman L.; van der Veen, Jan T.; van der Veen, J.T.; Segerink, Franciscus B.; Wessel, I.M.

    2010-01-01

    We describe a demonstration of a scanning probe microscope with shear-force tuning fork feedback. The tuning fork is several centimeters long, and the rigid fiber is replaced by a toothpick. By scaling this demonstration to visible dimensions the accessibility of shear-force scanning and tuning fork

  16. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1995-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in STM I, these studies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described in chapters on scanning force microscopy, magnetic force microscopy, and scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Together, the two volumes give a comprehensive account of experimental aspects of STM. They provide essential reading and reference material for all students and researchers involved in this field. In this second edition the text has been updated and new methods are discussed.

  17. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1992-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in Vol. I, these sudies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described inchapters on scanning force microscopy, magnetic force microscopy, scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Togehter, the two volumes give a comprehensive account of experimental aspcets of STM. They provide essentialreading and reference material for all students and researchers involvedin this field.

  18. EXAFS and EPR study of La0.6Sr0.2Ca0.2MnO3 and La0.6Sr0.2Ba0.2MnO3

    International Nuclear Information System (INIS)

    Yang, D.-K.Dong-Seok; Ulyanov, A.N.; Phan, Manh-Huong; Kim, Ikgyun; Ahn, Byong-Keun; Rhee, Jang Roh; Kim, Jung Sun; Nguyen, Chau; Yu, Seong-Cho

    2003-01-01

    Extended X-ray absorption fine structure (EXAFS) analysis and electron-paramagnetic resonance (EPR) have been used to examine the local structure and the internal dynamics of La 0.6 Sr 0.2 Ca 0.2 MnO 3 and La 0.6 Sr 0.2 Ba 0.2 MnO 3 lanthanum manganites. The Mn-O bond distance (∼1.94 Angst for both samples) and the Debye-Waller factors (0.36x10 -2 and 0.41x10 -2 Angst 2 for La 0.6 Sr 0.2 Ca 0.2 MnO 3 and for La 0.6 Sr 0.2 Ba 0.2 MnO 3 , respectively) were obtained from the EXAFS analysis. The dependence of the EPR line width on dopant kind (Ca or Ba) showed a decrease of the spin-lattice interaction with an increase of the Curie temperature. For both compositions, the EPR line intensity followed the exponential law I(T)=I 0 exp(E a /k B T), deduced on the basis of the adiabatic polaron hopping model

  19. An interchangeable scanning Hall probe/scanning SQUID microscope

    International Nuclear Information System (INIS)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-01-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10 −7 T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La 2/3 Ca 1/3 MnO 3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K

  20. An interchangeable scanning Hall probe/scanning SQUID microscope

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Chen, Tse-Jun; Wang, M. J. [Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 10617, Taiwan (China); Ling, D. C. [Department of Physics, Tamkang University, Tamsui Dist., New Taipei City 25137, Taiwan (China); Chi, C. C.; Chen, Jeng-Chung [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2014-08-15

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  1. Rapid-scan EPR imaging.

    Science.gov (United States)

    Eaton, Sandra S; Shi, Yilin; Woodcock, Lukas; Buchanan, Laura A; McPeak, Joseph; Quine, Richard W; Rinard, George A; Epel, Boris; Halpern, Howard J; Eaton, Gareth R

    2017-07-01

    In rapid-scan EPR the magnetic field or frequency is repeatedly scanned through the spectrum at rates that are much faster than in conventional continuous wave EPR. The signal is directly-detected with a mixer at the source frequency. Rapid-scan EPR is particularly advantageous when the scan rate through resonance is fast relative to electron spin relaxation rates. In such scans, there may be oscillations on the trailing edge of the spectrum. These oscillations can be removed by mathematical deconvolution to recover the slow-scan absorption spectrum. In cases of inhomogeneous broadening, the oscillations may interfere destructively to the extent that they are not visible. The deconvolution can be used even when it is not required, so spectra can be obtained in which some portions of the spectrum are in the rapid-scan regime and some are not. The technology developed for rapid-scan EPR can be applied generally so long as spectra are obtained in the linear response region. The detection of the full spectrum in each scan, the ability to use higher microwave power without saturation, and the noise filtering inherent in coherent averaging results in substantial improvement in signal-to-noise relative to conventional continuous wave spectroscopy, which is particularly advantageous for low-frequency EPR imaging. This overview describes the principles of rapid-scan EPR and the hardware used to generate the spectra. Examples are provided of its application to imaging of nitroxide radicals, diradicals, and spin-trapped radicals at a Larmor frequency of ca. 250MHz. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Are environmental scanning units effective?

    Science.gov (United States)

    Stubbart, C

    1982-06-01

    Many authorities have urged companies to set up environmental scanning to assist corporate planning. Some advocates have recommended a unit at corporate level. This would give breadth of view and penetration into the future. It would arm decision makers with accurate forecasts. The information would be broad in scope and future directed. It could provide also assumptions for long-range planning. The Fahey and King study produced a model of corporate scanning types. The data showed that environmental information was built into the plan. Though the political environment was important, scanning was inadequate. The best location for scanning was not at corporate level and most firms used irregular methods. The Thomas study concluded that effective environmental scanning was permanent and multi level and that 'best practice' was continuous scanning. In 1978 the sample organizations were revisited. Five of the twelve have not changed their practice. The factors which encouraged a continuous model were the attitudes of academics and business media, demonstrated success of the units, the right kind of personnel. Contrary influences were changes in top management, decentralization moves, resource cuts, defining the environment and its significance, the availability of scanning competent personnel, surprise itself, and the availability of alternatives e.g. external forecasts.

  3. Re-scan confocal microscopy: scanning twice for better resolution.

    Science.gov (United States)

    De Luca, Giulia M R; Breedijk, Ronald M P; Brandt, Rick A J; Zeelenberg, Christiaan H C; de Jong, Babette E; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A; Stallinga, Sjoerd; Manders, Erik M M

    2013-01-01

    We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required.

  4. Scanning by use of TV

    International Nuclear Information System (INIS)

    Drevermann, H.

    1981-01-01

    The use of TV read out for scanning and measuring holographic pictures seems to give less problems than the use of optical projection as is usual for conventional bubble chamber photos. Whereas the measuring of conventional bubble chamber pictures seems to give no problems, it is not clear whether scanning by use of TV is possible. Therefore scanning pictures from experiment NA16 (taken in LEBC) with TV only was tried using the TV system of ERASME, where the CRT system is used as a camera. It should be mentioned that this system, being a flying spot device, cannot be adapted for holography. (author)

  5. Tomography system having axial scanning

    International Nuclear Information System (INIS)

    1976-01-01

    An improved method and apparatus has been invented for the transaxial tomographic scanning of a patient to determine mass distribution internal to the patient. A scanning system is provided having a rotatably mounted X-ray radiation source/detector assembly which orbits and scans the patient in plane of orbit. The source provides a plurality of beams of radiation in the orbital plane. Beams pass through the patient to an array of detectors which are spaced in the plane of orbit and respectively aligned with one of the beams. Radiation intensity data is collected at predetermined orientations of each beam-detector pair as the assembly orbits about the patient

  6. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  7. Security scanning at 35 GHz

    Science.gov (United States)

    Anderton, Rupert N.; Appleby, Roger; Coward, Peter R.; Kent, P. J.; Price, Sean; Sinclair, Gordon N.; Wasley, Matthew R. M.

    2001-08-01

    It has been known for some time that millimeter waves can pas through clothing. In short range applications such as in the scanning of people for security purposes, operating at Ka band can be an advantage. The penetration through clothing is increased and the cost of the equipment when compared to operation at W band. In this paper a Ka band mechanically scanned imager designed for security scanning is discussed. This imager is based on the folded conical scan technology previously reported. It is constructed from low cost materials such as polystyrene and printed circuit board. The trade off between image spatial resolution and the number of receivers will be described and solutions, which minimize this number discussed.

  8. Scanning Tunneling Microscopy - image interpretation

    International Nuclear Information System (INIS)

    Maca, F.

    1998-01-01

    The basic ideas of image interpretation in Scanning Tunneling Microscopy are presented using simple quantum-mechanical models and supplied with examples of successful application. The importance is stressed of a correct interpretation of this brilliant experimental surface technique

  9. Transverse section radionuclide scanning system

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Edwards, R.Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program. 5 claims, 11 figures

  10. Dynamic Flaps Electronic Scan Antenna

    National Research Council Canada - National Science Library

    Gonzalez, Daniel

    2000-01-01

    A dynamic FLAPS(TM) electronic scan antenna was the focus of this research. The novelty S of this SBIR resides in the use of plasma as the main component of this dynamic X-Band phased S array antenna...

  11. Scan analysis in myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ell, P J [Landesunfallkrankenhaus, Feldkirch (Austria). Inst. fuer Strahlenmedizin

    1976-08-01

    Myocardial scans with sup(99m)Tc-labelled phosphates are reported to be useful in the diagnosis of acute myocardial infarction. A retrospective survey of 205 patients referred for sup(99m)Tc-phophate bone scanning and with no evidence of recent heart disease revealed an occurrence of 10% of false positive images, that is to say, uptake of phosphate in non-infarcted mayocardium. These striking findings stress the need for critical assessment of the usefulness of this diagnostic technique.

  12. Hepatobiliary scan in neonatal Jaundice

    International Nuclear Information System (INIS)

    Nahar, Nurun; Hasan, Mizanul; Karim, M.A.

    2002-01-01

    Jaundice is more or less common in newborn babies. Through physiological jaundice is most common cause of neonatal jaundice, possibility of obstructive jaundice especially biliary atresia should be kept in mind. Early diagnosis of biliary atresia followed by surgical treatment can save baby's life. Otherwise death is inevitable due to liver failure. Hepatobiliary scan is the imaging study of choice in neonatal jaundice especially when there is persistent conjugated hyperbilirubinaemia. Total 27 newborn babies of suspected biliary atresia, aged 14 days to 4 months were referred to Institute of Nuclear Medicine for Hepatobiliary scan. All of them had high serum bilirubin ranged from 6.0 mg/dl with an average of 9.35 ng/dl serum bilirubin level. Ultrasonography of hepatobiliary system was performed in 14 cases showing normal sized liver in 4 cases and hepatomegaly in 10 cases. Hepatobiliary scan was done with 99m Tc-Mebrofenin (Br IDA) after preparing the baby with phenobarbitone for 3-5 days. 20 (67%) cases were scan positive suggesting biliary atresia (BA) and 7(27%) cases were scan negative. In BA there will be increased hepatic uptake of the radionuclide without any significant excretion even in 24 hours delayed images. Presence of radiotracer in the bowel exclude the diagnosis of BA. Early diagnosis of biliary atresia is very important because in this condition surgery should be performed early (within 60 days of life). Studies suggest that hepatobiliary scan after hepatic stimulation with phenobarbitone for a period of 3-5 days is highly accurate for differentiating biliary atresia from other causes of neonatal jaundice. It is very important to perform hepatobiliary scan in a case of neonatal jaundice to exclude biliary atresia for the sake of baby's life.(author)

  13. Obstacles to Industrial Implementation of Scanning Systems

    Science.gov (United States)

    Anders Astrom; Olog Broman; John Graffman; Anders Gronlund; Armas Jappinene; Jari Luostarinen; Jan Nystrom; Daniel L. Schmoldt

    1998-01-01

    Initially the group discussed what is meant by scanning systems. An operational definition was adopted to consider scanning system in the current context to be nontraditional scanning. Where, traditional scanning is defined as scanning that has been industrially operational and relatively common for several years-a mature technology. For example,...

  14. Effect of Cu insertion on structural, local electronic/atomic structure and photocatalyst properties of TiO{sub 2}, ZnO and Ni(OH){sub 2} nanostructures: XANES-EXAFS study

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Aditya; Varshney, Mayora [Advanced Analysis Centre, Korea Institute of Science and Technology, Seoul, 02792 (Korea, Republic of); Shin, Hyun Joon, E-mail: shj001@postech.ac.kr [Pohang Accelerator Laboratory (POSTECH), Pohang, 37673 (Korea, Republic of); Lee, Byeong-Hyeon [Advanced Analysis Centre, Korea Institute of Science and Technology, Seoul, 02792 (Korea, Republic of); Chae, Keun Hwa, E-mail: khchae@kist.re.kr [Advanced Analysis Centre, Korea Institute of Science and Technology, Seoul, 02792 (Korea, Republic of); Won, Sung Ok, E-mail: sowon@kist.re.kr [Advanced Analysis Centre, Korea Institute of Science and Technology, Seoul, 02792 (Korea, Republic of)

    2017-04-15

    We report detailed investigations on the synthesis, structural, morphology, electronic/atomic structure and photocatalyst properties of Cu doped TiO{sub 2}, ZnO and Ni(OH){sub 2} nanostructures. All of the samples were synthesized by using the chemical precipitation method. Samples were characterized by X-ray diffraction (XRD), transmission electron microscope (TEM), X-ray absorption near edge structure (XANES), extended X-ray absorption fine structure (EXAFS) and photocatalyst measurements. XRD studies revealed single phase nature of the samples and omitted the presence of trivial metallic or binary oxide phases. TiO{sub 2} set of samples have shown nanorod kind of morphology, however TEM images of ZnO and Ni(OH){sub 2} set of samples depicted the spherical morphology of particles. XANES spectra at the Cu K-edge and Cu L-edge, along with the atomic multiplet calculations, revealed the predominance of Cu{sup 2+} ions in all of the samples, within the entire doping range. Ti L-edge and Ti K-edge XANES confirmed the existence of Ti{sup 4+} ions in the pure and Cu doped TiO{sub 2} samples with anatase local structure. Zn L-edge XANES results confirmed the divalent character of Zn ions in the pure and Cu doped ZnO, which is further validated by the Zn K-edge XANES. Ni L-edge and Ni K-edge XANES conveyed the +2 valence state of Ni ions in the pure and Cu doped Ni (OH){sub 2} samples. EXAFS analysis at the Cu K-edge nullifies the formation of Cu metallic clusters and other trivial phases, suggesting random distribution of Cu atoms in the oxide materials. Though, local atomic arrangement of Cu ions is disparate in the different oxide compounds. As an application of the pure and Cu doped TiO{sub 2}, ZnO and Ni(OH){sub 2} nanostructures, towards the degradation of water pollutant dyes, we demonstrate that all of the samples can serve as effective photocatalyst materials towards the degradation of methyl orange aqueous pollutant dye under the UV-light irradiation

  15. Interesting bone scans - unusual findings

    International Nuclear Information System (INIS)

    Dobson, M.; Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.

    1997-01-01

    A 59-year-old female with carcinoma of the colon and known liver metastatic disease was referred for bone scan to evaluate for bone metastases. Although no bone metastases were found, there was abnormal uptake noted in the liver corresponding to a metastatic calcified lesion. The only other findings were of degenerative disease in the cervical spine, right shoulder and small joints of the hands. A 69-year-old male with carcinoma of the prostate and right side low back pain was referred for bone scan. No focal abnormalities to suggest metastatic disease were identified; findings within the cervical spine, lumber spine and knees were presumed secondary to degenerative disease. Intermittent pain persisted and the patient was referred for a repeat bone scan six months later. Previous scan findings of degenerative disease and no metastatic disease were confirmed; however, closer inspection revealed an enlarged right kidney with significant retention of tracer in the pelvicalyceal system suggesting possible obstruction. A Retrograde pyelogram was performed, and no obvious obstruction demonstrated. As bone scan findings were very suggestive of obstruction, a DTPA scan with lasix was performed showing a dilated right collecting system with no functional obstruction. Given the degree of dilation, it is possible that the patient experiences intermittent PUJ obstruction causing his symptoms. A 33-year-old male with insulin dependent diabetes mellitus and viral arthritis was referred for a bone scan. A three phase revealed increased uptake in the region of the knee and leR proximal tibia. Delayed whole body images revealed multiple focal areas of osteoblastic activity in the leR tibia. Abnormal uptake was also seen in the upper third of the leR femur. The remainder of the skeletal survey was normal. X-ray correlation of the leR tibia and femoral findings was undertaken. Combinating unilateral changes on bone scan and X-ray although very suggestive of sclerotic polyostotic

  16. The boundary-scan handbook

    CERN Document Server

    Parker, Kenneth P

    2016-01-01

    Aimed at electronics industry professionals, this 4th edition of the Boundary Scan Handbook describes recent changes to the IEEE1149.1 Standard Test Access Port and Boundary-Scan Architecture. This updated edition features new chapters on the possible effects of the changes on the work of the practicing test engineers and the new 1149.8.1 standard. Anyone needing to understand the basics of boundary scan and its practical industrial implementation will need this book. Provides an overview of the recent changes to the 1149.1 standard and the effect of the changes on the work of test engineers;   Explains the new IEEE 1149.8.1 subsidiary standard and applications;   Describes the latest updates on the supplementary IEEE testing standards. In particular, addresses: IEEE Std 1149.1                      Digital Boundary-Scan IEEE Std 1149.4                      Analog Boundary-Scan IEEE Std 1149.6                      Advanced I/O Testing IEEE Std 1149.8.1           �...

  17. CAMAC gamma ray scanning system

    International Nuclear Information System (INIS)

    Moss, C.E.; Pratt, J.C.; Shunk, E.R.

    1981-01-01

    A flexible gamma-ray scanning system, based on a LeCroy 3500 multichannel analyzer and CAMAC modules, is described. The system is designed for making simultaneous passive and active scans of objects of interest to nuclear safeguards. The scanner is a stepping-motor-driven carriage; the detectors, a bismuth-germanate scintillator and a high-purity germanium detector. A total of sixteen peaks in the two detector-produced spectra can be integrated simultaneously, and any scan can be viewed during data acquisition. For active scanning, the 2615-keV gamma-ray line from a 232 U source and the 4439-keV gamma-ray line from 9 Be(α,n) 12 C were selected. The system can be easily reconfigured to accommodate up to seven detectors because it is based on CAMAC modules and FORTRAN. The system is designed for field use and is easily transported. Examples of passive and active scans are presented

  18. Influence of 300°C thermal conversion of Fe-Ce hydrous oxides prepared by hydrothermal precipitation on the adsorptive performance of five anions: Insights from EXAFS/XANES, XRD and FTIR (companion paper)

    KAUST Repository

    Chubar, Natalia; Gerda, Vasyl; Banerjee, Dipanjan

    2016-01-01

    In this work, we report atomic-scale reconstruction processes in Fe-Ce oxide-based composites (hydrothermally precipitated at Fe-to-Ce dosage ratios of 1:0, 2:1, 1:1, 1:2, and 0:1), upon treatment at 300 °C. The structural changes are correlated with the adsorptive removal of arsenate, phosphate, fluoride, bromide, and bromate. The presence of the carbonate-based Ce-component and surface sulfate in precursor samples creates favorable conditions for phase transformation, resulting in the formation of novel (unknown) layered compounds of Fe and Ce. These compounds are of the layered double hydroxide type, with sulfate in the interlayer space. In spite of general awareness of the importance of surface area in adsorptive removal, the increase in surface area upon thermal treatment did not increase adsorption of the studied anions. However, EXAFS simulations and the adsorption tests provided evidence of regularities between local structures of Fe in composites obtained at 80 and 300 °C and adsorption performance of most studied anions. The best adsorption of tetrahedral anions was demonstrated by samples whose simulated outer Fe shells resulted from oscillations from both O and Fe atoms. In contrast, the loss of extended x-ray absorption fine structure was correlated with the decrease of adsorptive removal. Both Fe K-edge and Ce L3 -edge EXAFS suggested the formation of solid solutions. For the first time, the utilization of extended x-ray absorption fine structure is suggested as a methodological approach (first expressed in the companion paper) to estimate the surface reactivity of inorganic materials intended for use as anion exchange adsorbents.

  19. Influence of 300°C thermal conversion of Fe-Ce hydrous oxides prepared by hydrothermal precipitation on the adsorptive performance of five anions: Insights from EXAFS/XANES, XRD and FTIR (companion paper)

    KAUST Repository

    Chubar, Natalia

    2016-12-07

    In this work, we report atomic-scale reconstruction processes in Fe-Ce oxide-based composites (hydrothermally precipitated at Fe-to-Ce dosage ratios of 1:0, 2:1, 1:1, 1:2, and 0:1), upon treatment at 300 °C. The structural changes are correlated with the adsorptive removal of arsenate, phosphate, fluoride, bromide, and bromate. The presence of the carbonate-based Ce-component and surface sulfate in precursor samples creates favorable conditions for phase transformation, resulting in the formation of novel (unknown) layered compounds of Fe and Ce. These compounds are of the layered double hydroxide type, with sulfate in the interlayer space. In spite of general awareness of the importance of surface area in adsorptive removal, the increase in surface area upon thermal treatment did not increase adsorption of the studied anions. However, EXAFS simulations and the adsorption tests provided evidence of regularities between local structures of Fe in composites obtained at 80 and 300 °C and adsorption performance of most studied anions. The best adsorption of tetrahedral anions was demonstrated by samples whose simulated outer Fe shells resulted from oscillations from both O and Fe atoms. In contrast, the loss of extended x-ray absorption fine structure was correlated with the decrease of adsorptive removal. Both Fe K-edge and Ce L3 -edge EXAFS suggested the formation of solid solutions. For the first time, the utilization of extended x-ray absorption fine structure is suggested as a methodological approach (first expressed in the companion paper) to estimate the surface reactivity of inorganic materials intended for use as anion exchange adsorbents.

  20. On the molecular basis of the activity of the antimalarial drug chloroquine: EXAFS-assisted DFT evidence of a direct Fe–N bond with free heme in solution

    International Nuclear Information System (INIS)

    Macetti, Giovanni; Rizzato, Silvia; Beghi, Fabio; Presti, Leonardo Lo; Silvestrini, Lucia

    2016-01-01

    4-aminoquinoline antiplasmodials interfere with the biocrystallization of the malaria pigment, a key step of the malaria parasite metabolism. It is commonly believed that these drugs set stacking π···π interactions with the Fe-protoporphyrin scaffold of the free heme, even though the details of the heme:drug recognition process remain elusive. In this work, the local coordination of Fe(III) ions in acidic solutions of hematin at room temperature was investigated by extended x-ray absorption fine structure (EXAFS) spectroscopy in the 4.0–5.5 pH range, both in the presence and in the absence of the antimalarial drug chloroquine. EXAFS results were complemented by DFT simulations in polarizable continuum media to model solvent effects. We found evidence that a complex where the drug quinoline nitrogen is coordinated with the iron center might coexist with formerly proposed adduct geometries, based on stacking interactions. Charge-assisted hydrogen bonds among lateral chains of the two molecules play a crucial role in stabilizing this complex, whose formation is favored by the presence of lipid micelles. The direct Fe–N bond could reversibly block the axial position in the Fe 1st coordination shell in free heme, acting as an inhibitor for the crystallization of the malaria pigment without permanently hampering the catalytic activity of the redox center. These findings are discussed in the light of possible implications on the engineering of drugs able to thwart the adaptability of the malaria parasite against classical aminoquinoline-based therapies. (invited comment)

  1. On the molecular basis of the activity of the antimalarial drug chloroquine: EXAFS-assisted DFT evidence of a direct Fe-N bond with free heme in solution

    Science.gov (United States)

    Macetti, Giovanni; Rizzato, Silvia; Beghi, Fabio; Silvestrini, Lucia; Lo Presti, Leonardo

    2016-02-01

    4-aminoquinoline antiplasmodials interfere with the biocrystallization of the malaria pigment, a key step of the malaria parasite metabolism. It is commonly believed that these drugs set stacking π···π interactions with the Fe-protoporphyrin scaffold of the free heme, even though the details of the heme:drug recognition process remain elusive. In this work, the local coordination of Fe(III) ions in acidic solutions of hematin at room temperature was investigated by extended x-ray absorption fine structure (EXAFS) spectroscopy in the 4.0-5.5 pH range, both in the presence and in the absence of the antimalarial drug chloroquine. EXAFS results were complemented by DFT simulations in polarizable continuum media to model solvent effects. We found evidence that a complex where the drug quinoline nitrogen is coordinated with the iron center might coexist with formerly proposed adduct geometries, based on stacking interactions. Charge-assisted hydrogen bonds among lateral chains of the two molecules play a crucial role in stabilizing this complex, whose formation is favored by the presence of lipid micelles. The direct Fe-N bond could reversibly block the axial position in the Fe 1st coordination shell in free heme, acting as an inhibitor for the crystallization of the malaria pigment without permanently hampering the catalytic activity of the redox center. These findings are discussed in the light of possible implications on the engineering of drugs able to thwart the adaptability of the malaria parasite against classical aminoquinoline-based therapies.

  2. Fischer-Tropsch synthesis: study of the promotion of Pt on the reduction property of Co/Al2O3 catalysts by in situ EXAFS of Co K and Pt LIII edges and XPS

    International Nuclear Information System (INIS)

    Jacobs, G.; Chaney, J.A.; Patterson, P.M.; Das, T.K.; Maillot, J.C.; Davis, B.H.

    2004-01-01

    The addition of platinum metal to cobalt/alumina-based Fischer-Tropsch synthesis (FTS) catalysts increases both the reduction rate and, consequently, the density of active cobalt sites. Platinum also lowers the temperature of the two-step conversion of cobalt oxide to cobalt metal observed in temperature programmed reduction (TPR) as Co 3 O 4 to CoO and CoO to Co 0 . The interaction of the alumina support with cobalt oxide ultimately determines the active site density of the catalyst surface. This interaction can be controlled by varying the cobalt loading and dispersion, selecting supports with differing surface areas or pore sizes, or changing the noble metal promoter. However, the active site density is observed to depend primarily on the cluster size and extent of reduction, and there is a direct relationship between site density and FTS rate. In this work, in situ extended X-ray absorption fine structure (EXAFS) at the L III edge of Pt was used to show that isolated Pt atoms interact with supported cobalt clusters without forming observable Pt-Pt bonds. K-edge EXAFS was also used to verify that the cobalt cluster size increases slightly for those systems with Pt promotion. X-ray absorption near-edge spectroscopy (XANES) was used to examine the remaining cobalt clusters after the first stage of TPR, and it revealed that the species were almost entirely cobalt (II) oxide. After the second stage of TPR to form cobalt metal, a residual oxide persists in the sample, and this oxide has been identified as cobalt (II) aluminate using X-ray photoelectron spectroscopy (XPS). Sequential in situ reduction of promoted and unpromoted systems was also monitored through XPS, and Pt was seen to increase the extent of cobalt reduction by a factor of two. (orig.)

  3. Security scanning at 94GHz

    Science.gov (United States)

    Anderton, Rupert N.; Appleby, Roger; Beale, John E.; Coward, Peter R.; Price, Sean

    2006-05-01

    It is well known that millimetre waves can pass through clothing. In short range applications such as in the scanning of people for security purposes, operating at W band can be an advantage. The size of the equipment is decreased when compared to operation at Ka band and the equipments have similar performance. In this paper a W band mechanically scanned imager designed for imaging weapons and contraband hidden under clothing is discussed. This imager is based on a modified folded conical scan technology previously reported. In this design an additional optical element is added to give a Cassegrain configuration in image space. This increases the effective focal length and enables improved sampling of the image and provides more space for the receivers. This imager is constructed from low cost materials such as polystyrene, polythene and printed circuit board materials. The trade off between image spatial resolution and thermal sensitivity is discussed.

  4. Scanning Terahertz Heterodyne Imaging Systems

    Science.gov (United States)

    Siegel, Peter; Dengler, Robert

    2007-01-01

    Scanning terahertz heterodyne imaging systems are now at an early stage of development. In a basic scanning terahertz heterodyne imaging system, (see Figure 1) two far-infrared lasers generate beams denoted the local-oscillator (LO) and signal that differ in frequency by an amount, denoted the intermediate frequency (IF), chosen to suit the application. The LO beam is sent directly to a mixer as one of two inputs. The signal beam is focused to a spot on or in the specimen. After transmission through or reflection from the specimen, the beams are focused to a spot on a terahertz mixer, which extracts the IF outputs. The specimen is mounted on a translation stage, by means of which the focal spot is scanned across the specimen to build up an image.

  5. Scanning vector Hall probe microscopy

    International Nuclear Information System (INIS)

    Cambel, V.; Gregusova, D.; Fedor, J.; Kudela, R.; Bending, S.J.

    2004-01-01

    We have developed a scanning vector Hall probe microscope for mapping magnetic field vector over magnetic samples. The microscope is based on a micromachined Hall sensor and the cryostat with scanning system. The vector Hall sensor active area is ∼5x5 μm 2 . It is realized by patterning three Hall probes on the tilted faces of GaAs pyramids. Data from these 'tilted' Hall probes are used to reconstruct the full magnetic field vector. The scanning area of the microscope is 5x5 mm 2 , space resolution 2.5 μm, field resolution ∼1 μT Hz -1/2 at temperatures 10-300 K

  6. Footwear scanning systems and methods

    Science.gov (United States)

    Fernandes, Justin L.; McMakin, Douglas L.; Sheen, David M.; Tedeschi, Jonathan R.

    2017-07-25

    Methods and apparatus for scanning articles, such as footwear, to provide information regarding the contents of the articles are described. According to one aspect, a footwear scanning system includes a platform configured to contact footwear to be scanned, an antenna array configured to transmit electromagnetic waves through the platform into the footwear and to receive electromagnetic waves from the footwear and the platform, a transceiver coupled with antennas of the antenna array and configured to apply electrical signals to at least one of the antennas to generate the transmitted electromagnetic waves and to receive electrical signals from at least another of the antennas corresponding to the electromagnetic waves received by the others of the antennas, and processing circuitry configured to process the received electrical signals from the transceiver to provide information regarding contents within the footwear.

  7. Double-polarizating scanning radiometer

    International Nuclear Information System (INIS)

    Mishev, D.N.; Nazyrski, T.G.

    1986-01-01

    The double-polarizating single-channel scanning radiometer comprises the following serial connected parts: a scanning double-polarizating aerial, a block for polarization separation, a radiometer receiver, an analog-to-digit converter and an information flow forming block. The low frequency input of the radiometer receiver is connected with a control block, which is also connected with a first bus of a microprocessor, the second bus of which is connected with the A-D converter. The control input of the scanning double-polarizating aerial is connected with the first microprocessor bus. The control inputs of the block for polarization separation are linked by an electronic switch with the output of the forming block, the input of which is connected to the first input of the control block. The control inputs of the block for polarization separation are connected with the second and the third input of the information flow forming block. 2 cls

  8. Scanning probe microscopy competency development

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, M.E.; Reagor, D.W.; Jia, Quan Xi [and others

    1998-12-31

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The project collaborators developed an ultra-high vacuum scanning tunneling microscope (UHV-STM) capability, integrated it with existing scanning probe microscopes, and developed new, advanced air-based scanning force techniques (SPMs). Programmatic, basic, and industrially related laboratory research requires the existence of SPMs, as well as expertise capable of providing local nano-scale information. The UHV-STM capability, equipped with load-lock system and several surface science techniques, will allow introduction, examination, and reaction of surfaces prepared under well-controlled vacuum conditions, including the examination of morphology and local bonding associated with the initial stages of film growth under controlled growth conditions. The resulting capabilities will enable the authors to respond to a variety of problems requiring local characterization of conducting and nonconducting surfaces in liquids, air, and UHV.

  9. Producing colour pictures from SCAN

    International Nuclear Information System (INIS)

    Robichaud, K.

    1982-01-01

    The computer code SCAN.TSK has been written for use on the Interdata 7/32 minicomputer which will convert the pictures produced by the SCAN program into colour pictures on a colour graphics VDU. These colour pictures are a more powerful aid to detecting errors in the MONK input data than the normal lineprinter pictures. This report is intended as a user manual for using the program on the Interdata 7/32, and describes the method used to produce the pictures and gives examples of JCL, input data and of the pictures that can be produced. (U.K.)

  10. Linking world scan and image

    International Nuclear Information System (INIS)

    Timmer, H.; Alcamo, J.; Bollen, J.; Gielen, A.; Gerlach, R.; Den Ouden, A.; Zuidema, G.

    1995-01-01

    In march 1994 the Central Planning Bureau (CPB) in the Hague, the National Institute of Public Health and Environmental Protection (RIVM) in Bilthoven and the Institute of Environmental Studies (IES) in Amsterdam started the first phase of a joint research program aimed at creating integrated scenarios of the global economy, GHG emissions, and climate impacts. The goal of the first phase of this project was to design and test a linked version of the economic model WORLD SCAN of the former, and the climate model IMAGE 2 of the latter institute. This first phase has resulted in the planned test runs with an operational version of the linked models by May 1995. The experiences in the first year were encouraging, both in the scientific and the organizational sense. In a sense, a link was made between scientific disciplines: a coupling of disciplines concerning with global economic development and the global physical climate system is difficult and novel. The goal of the project was to integrate long-term economic developments and effects of climate change. Both the WORLD SCAN model and IMAGE 2 provide a consistent analysis of the global system, but from different perspectives. IMAGE 2 simulates climate change and its effects in a global context but treats the economic system as exogenous. WORLD SCAN covers the world economic system in a consistent manner but does not take into account the global environment. The links are constructed in the area of agriculture and energy. The basic idea is that WORLD SCAN determines demand and supply on economic principles, while IMAGE 2 provides information on changes of land area and average quality of productive land, and other damage costs based on its three sub-systems. The demand for energy is fed into IMAGE 2's Energy Industry subsystem (EIS), which in turn determines emissions of greenhouse gases. Furthermore, some additional output from WORLD SCAN on activity levels, prices and capital structure can be used to determine

  11. Advanced HEDL gamma scan system

    International Nuclear Information System (INIS)

    Smith, F.C.; Olson, R.N.

    1983-01-01

    The design of an advanced state-of-the-art gamma scan system built for the purpose of measuring the point-by-point gamma activity of irradiated fuel rods is described. The emphasis of the system design was to achieve the highest rate of throughput with the minimum per rod cost while maintaining system accuracy and reliability. Preliminary tests demonstrate that all system requirements were met or exceeded. The system provides improved throughput, precision, automation, flexibility, and data processing capability over previous gamma scan systems

  12. Electronically-Scanned Pressure Sensors

    Science.gov (United States)

    Coe, C. F.; Parra, G. T.; Kauffman, R. C.

    1984-01-01

    Sensors not pneumatically switched. Electronic pressure-transducer scanning system constructed in modular form. Pressure transducer modules and analog to digital converter module small enough to fit within cavities of average-sized wind-tunnel models. All switching done electronically. Temperature controlled environment maintained within sensor modules so accuracy maintained while ambient temperature varies.

  13. High Resolution Scanning Ion Microscopy

    NARCIS (Netherlands)

    Castaldo, V.

    2011-01-01

    The structure of the thesis is the following. The first chapter is an introduction to scanning microscopy, where the path that led to the Focused Ion Beam (FIB) is described and the main differences between electrons and ion beams are highlighted. Chapter 2 is what is normally referred to (which I

  14. Bone Densitometry (Bone Density Scan)

    Science.gov (United States)

    ... made of metal. Objects such as keys or wallets that would be in the area being scanned should be removed. You will ... and are often available in drugstores and on mobile health vans in the community. The pDEXA device is much smaller than ...

  15. Nanobits: customizable scanning probe tips

    DEFF Research Database (Denmark)

    Kumar, Rajendra; Shaik, Hassan Uddin; Sardan Sukas, Özlem

    2009-01-01

    We present here a proof-of-principle study of scanning probe tips defined by planar nanolithography and integrated with AFM probes using nanomanipulation. The so-called 'nanobits' are 2-4 mu m long and 120-150 nm thin flakes of Si3N4 or SiO2, fabricated by electron beam lithography and standard s...

  16. Scanning tunneling microscope nanoetching method

    Science.gov (United States)

    Li, Yun-Zhong; Reifenberger, Ronald G.; Andres, Ronald P.

    1990-01-01

    A method is described for forming uniform nanometer sized depressions on the surface of a conducting substrate. A tunneling tip is used to apply tunneling current density sufficient to vaporize a localized area of the substrate surface. The resulting depressions or craters in the substrate surface can be formed in information encoding patterns readable with a scanning tunneling microscope.

  17. Introduction to scanning tunneling microscopy

    CERN Document Server

    Chen, C Julian

    2008-01-01

    The scanning tunneling and the atomic force microscope, both capable of imaging individual atoms, were crowned with the Physics Nobel Prize in 1986, and are the cornerstones of nanotechnology today. This is a thoroughly updated version of this 'bible' in the field.

  18. CT scan of Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, T; Noguchi, S; Nishitani, H [National Sanatorium of Utano, Kyoto (Japan); Kitano, H; Ikegami, Y

    1981-04-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs.

  19. Bone scan indications in oncology

    International Nuclear Information System (INIS)

    Rocha, A.F.G. da; Marquiotti, M.

    1986-01-01

    The scintigraphic method is described and a critical analysis of its value in the research of bone metastases is presented. The method validity, the positivity of bone scan for metastases at the first examination and the preferencial distribution metastases in skeleton are related.Bone pain and the results of bone scintigram are correlated. (M.A.C.) [pt

  20. CT scan of Parkinson's disease

    International Nuclear Information System (INIS)

    Konishi, Tetsuro; Noguchi, Sadako; Nishitani, Hiroshi; Kitano, Haruo; Ikegami, Yoshinori.

    1981-01-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs. (author)

  1. Pulmonary ventilation/perfusion scan

    Science.gov (United States)

    ... to stop eating (fast), be on a special diet, or take any medicines before the test. A chest x-ray is usually done before or after a ventilation and perfusion scan. You wear a hospital gown or comfortable clothing that does not have ...

  2. Scanning Quantum Cryogenic Atom Microscope

    Science.gov (United States)

    Yang, Fan; Kollár, Alicia J.; Taylor, Stephen F.; Turner, Richard W.; Lev, Benjamin L.

    2017-03-01

    Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials. However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers. We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution. The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating. The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μ m ) or 6 nT /√{Hz } per point at its duty cycle. Compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT /√{Hz } for each point during the same time as a point-by-point scanner measures these points sequentially. Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10-6 Φ0/√{Hz } ) over previous atomic probe magnetometers capable of scanning near samples. These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged. We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.

  3. Seismic scanning tunneling macroscope - Theory

    KAUST Repository

    Schuster, Gerard T.

    2012-09-01

    We propose a seismic scanning tunneling macroscope (SSTM) that can detect the presence of sub-wavelength scatterers in the near-field of either the source or the receivers. Analytic formulas for the time reverse mirror (TRM) profile associated with a single scatterer model show that the spatial resolution limit to be, unlike the Abbe limit of λ/2, independent of wavelength and linearly proportional to the source-scatterer separation as long as the point scatterer is in the near-field region; if the sub-wavelength scatterer is a spherical impedance discontinuity then the resolution will also be limited by the radius of the sphere. Therefore, superresolution imaging can be achieved as the scatterer approaches the source. This is analogous to an optical scanning tunneling microscope that has sub-wavelength resolution. Scaled to seismic frequencies, it is theoretically possible to extract 100 Hz information from 20 Hz data by imaging of near-field seismic energy.

  4. /sup 67/Ga lung scan

    Energy Technology Data Exchange (ETDEWEB)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-03-21

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate /sup 67/Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the /sup 67/Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of /sup 67/Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of /sup 67/Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography.

  5. Automation of BESSY scanning tables

    International Nuclear Information System (INIS)

    Hanton, J.; Kesteman, J.

    1981-01-01

    A micro processor M6800 is used for the automation of scanning and premeasuring BESSY tables. The tasks achieved by the micro processor are: 1. control of spooling of the four asynchronous film winding devices and switching on and off the 4 projections lamps, 2. pre-processing of the data coming from a bi-polar coordinates measuring device, 3. bi-directional interchange of informations between the operator, the BESSY table and the DEC PDP 11/34 mini computer controling the scanning operations, 4. control of the magnification on the table by swapping the projection lenses of appropriate focal lengths and the associated light boxes (under development). In connection with point 4, study is being made for the use of BESSY tables for accurate measurements (+/-5 microns), by encoding the displacements of the projections lenses. (orig.)

  6. Seismic scanning tunneling macroscope - Theory

    KAUST Repository

    Schuster, Gerard T.; Hanafy, Sherif M.; Huang, Yunsong

    2012-01-01

    We propose a seismic scanning tunneling macroscope (SSTM) that can detect the presence of sub-wavelength scatterers in the near-field of either the source or the receivers. Analytic formulas for the time reverse mirror (TRM) profile associated with a single scatterer model show that the spatial resolution limit to be, unlike the Abbe limit of λ/2, independent of wavelength and linearly proportional to the source-scatterer separation as long as the point scatterer is in the near-field region; if the sub-wavelength scatterer is a spherical impedance discontinuity then the resolution will also be limited by the radius of the sphere. Therefore, superresolution imaging can be achieved as the scatterer approaches the source. This is analogous to an optical scanning tunneling microscope that has sub-wavelength resolution. Scaled to seismic frequencies, it is theoretically possible to extract 100 Hz information from 20 Hz data by imaging of near-field seismic energy.

  7. Fast-scan NMR imaging

    International Nuclear Information System (INIS)

    Iwaoka, Hideto; Matsuura, Hiroyuki; Sugiyama, Tadashi; Hirata, Takaaki

    1987-01-01

    This paper describes the Fast Recovery (FR) method for fast-scan Nuclear Magnetic Resonance imaging. The FR method uses a sequence of four radio frequency pulses - alternating selective 90 deg nutation pulses and nonselective 180 deg pulses. One free induction decay (FID) signal and one echo signal are detected and averaged to compute a 2-D image. In the modified FR method, extra 180 deg pulses are applied between 90 deg pulses to cause refocusing and the resultant spin echo signals are averaged to improve the signal to noise ratio. For the FR and modified FR sequences, the macroscopic magnetization is restored to equilibrium quickly and exactly; scan time can consequently be less than that for conventional pulse sequences, such as used in the saturation recovery method, without any penalty in signal to noise ratio. This paper derives expressions for the signal to noise ratio, scan time ratio and contrast noise ratio, compares the FR and modified FR methods with the saturation recovery method and presents experimental results for human body images. In theory and practice, the signal to noise ratio for the FR method is larger than that for the modified FR method. For a given signal to noise ratio the scan time is between one half and one fourth that for the saturation recovery method. The optimum repetition period, T r , is 0.07 ∼ 0.25 s for the FR method, and 0.1 ∼ 0.5 s for the modified FR method. Contrast noise ratio is low for high speed imaging, T r = 0.07 ∼ 0.25 s, but, high contrast noise ratio image is obtained for T r > 0.5 s. (author)

  8. First PET scans in Estonia

    International Nuclear Information System (INIS)

    Nazarenko, Sergei

    2003-01-01

    First PET scans in Estonia were performed on 25th November 2002 in North Estonia Regional Hospital, Tallinn. Six patients with melanoma underwent scanning with FDG. This event was a result of thorough extensive preparations first started in 2000 during the European Association of Nuclear Medicine congress in Paris. During the congress first contacts were made with providers of mobile PET units. At the same time negotiations were begun with potential FDG suppliers. For the introduction of PET in Estonia mobile truckmounted scanning technology was chosen due to low level of initial investments. Of particular importance was also availability of maintenance personnel from the device providers. A significant prerequisite was potential availability of FDG from the neighbourhood - Finland and Sweden. The latter avoided the necessity for investments into local cyclotrons and local FDG production. For the first scanning experience the dedicated truckmounted PET-camera Accel, Siemens was brought by the International Hospital Group (IHG, Amersfoort, Netherlands). The device arrived by ferry from Stockholm to Tallinn harbour at 10 o'clock in the morning and left by ferry for Helsinki at 23 o'clock. The team-on-truck consisted of one technician for device operation, two drivers and two company representatives. North Estonia Regional Hospital provided three additional technicians for patient preparation and FDG injection, one nuclear medicine doctor and one specialist of biomedical engineering and medical physics. The FDG was provided by MAP Medical Technologies, Schering, Helsinki, Finland. The shipments were made by air. This was possible due to small distance between Tallinn and Helsinki of approximately 80 km due to the regular flight connections between the two cities. The FDG was shipped in two lots with a time interval of 4 hours. The patient selection was based on clinical and histopathology data. In all six patients the exam was justified for detailied staging and

  9. A new ultrasensitive scanning calorimeter.

    Science.gov (United States)

    Plotnikov, V V; Brandts, J M; Lin, L N; Brandts, J F

    1997-08-01

    A new ultrasensitive differential scanning calorimeter is described, having a number of novel features arising from integration between hardware and software. It is capable of high performance in either a scanning or isothermal mode of operation. Upscanning is carried out adiabatically while downscanning is nonadiabatic. By using software-controlled signals sent continuously to appropriate hardware devices, it is possible to improve adiabaticity and constancy of scan rate through use of empirical prerun information stored in memory rather than by using feedback systems which respond in real time and generate thermal noise. Also, instrument response time is software-selectable, maximizing performance for both slow- and fast-transient systems. While these and other sophisticated functionalities have been introduced into the instrument to improve performance and data analysis, they are virtually invisible and add no additional complexities into operation of the instrument. Noise and baseline repeatability are an order of magnitude better than published raw data from other instruments so that high-quality results can be obtained on protein solutions, for example, using as little as 50 microg of protein in the sample cell.

  10. New Snail Mail Scanning Service

    CERN Multimedia

    2012-01-01

    Modernisation does not stop at the CERN postal service (GS/PS). “With more and more digitisation and the prevalence of e-mail throughout the site, we were hoping to provide more timely delivery of letters and make further saving in resources”, said Tueri Datta, head of GS/PS.   Instead of the standard delivery to your P.O. box, the CERN postal service will digitally scan all letters and books up to 100 pages on reception. These scans will subsequently be sent via e-mail to the corresponding recipient as PDF (Portable Data Format - you will need to install “Acrobat Reader” on your PC). Express mail will be handled with priority. Users without a valid CERN mailbox can register at mail.scan.service@cern.ch in order to have their letters read to them via the phone line (we are currently investigating whether we can use the voices of the last five DGs).   This service will start on 1st April 2012 on the Meyrin site and will gradually replace th...

  11. Multiple myeloma: radiology or bone scanning

    International Nuclear Information System (INIS)

    Leonard, R.C.F.; Owen, J.P.; Proctor, S.J.; Hamilton, P.J.

    1981-01-01

    A comparative study of radionuclide bone scanning and skeletal radiology in patients with multiple myeloma revealed four principal findings: (i) There were no cases of negative bone scans with positive skeletal radiographs. (ii) Lytic bone lesions were seriously underestimated by bone scans. (iii) Bone scans tended to pick up lesions in ribs missed on the skeletal surveys. (iv) Patients with bone pain were more likely to have positive bone scans and skeletal radiographs than asymptomatic patients. (author)

  12. Vertical Scan-Conversion for Filling Purposes

    OpenAIRE

    Hersch, R. D.

    1988-01-01

    Conventional scan-conversion algorithms were developed independently of filling algorithms. They cause many problems, when used for filling purposes. However, today's raster printers and plotters require extended use of filling, especially for the generation of typographic characters and graphic line art. A new scan-conversion algorithm, called vertical scan-conversion has been specifically designed to meet the requirements of parity scan line fill algorithms. Vertical scan-conversion ensures...

  13. The O2-Evolving Complex of Photosystem II: Recent Insights from Quantum Mechanics/Molecular Mechanics (QM/MM), Extended X-ray Absorption Fine Structure (EXAFS), and Femtosecond X-ray Crystallography Data.

    Science.gov (United States)

    Askerka, Mikhail; Brudvig, Gary W; Batista, Victor S

    2017-01-17

    Efficient photoelectrochemical water oxidation may open a way to produce energy from renewable solar power. In biology, generation of fuel due to water oxidation happens efficiently on an immense scale during the light reactions of photosynthesis. To oxidize water, photosynthetic organisms have evolved a highly conserved protein complex, Photosystem II. Within that complex, water oxidation happens at the CaMn 4 O 5 inorganic catalytic cluster, the so-called oxygen-evolving complex (OEC), which cycles through storage "S" states as it accumulates oxidizing equivalents and produces molecular oxygen. In recent years, there has been significant progress in understanding the OEC as it evolves through the catalytic cycle. Studies have combined conventional and femtosecond X-ray crystallography with extended X-ray absorption fine structure (EXAFS) and quantum mechanics/molecular mechanics (QM/MM) methods and have addressed changes in protonation states of μ-oxo bridges and the coordination of substrate water through the analysis of ammonia binding as a chemical analog of water. These advances are thought to be critical to understanding the catalytic cycle since protonation states regulate the relative stability of different redox states and the geometry of the OEC. Therefore, establishing the mechanism for substrate water binding and the nature of protonation/redox state transitions in the OEC is essential for understanding the catalytic cycle of O 2 evolution. The structure of the dark-stable S 1 state has been a target for X-ray crystallography for the past 15 years. However, traditional X-ray crystallography has been hampered by radiation-induced reduction of the OEC. Very recently, a revolutionary X-ray free electron laser (XFEL) technique was applied to PSII to reveal atomic positions at 1.95 Å without radiation damage, which brought us closer than ever to establishing the ultimate structure of the OEC in the S 1 state. However, the atom positions in this crystal

  14. The role of the A ion in the Fe local structure of the AFe{sub 2}As{sub 2} systems (A=Sr, Eu, Ba): an EXAFS study

    Energy Technology Data Exchange (ETDEWEB)

    Tobia, Dina; Radaelli, Matheus; Piva, Mario Moda; Lesseux, Guilherme Gorgen; Jesus, Camilo Bruno Ramos; Urbano, Ricardo Rodrigues; Granado, Eduardo; Pagliuso, Pascoal G., E-mail: ifitobia@ifi.unicamp.br [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Instituto de Fisica Gleb Wataghin; Saleta, Martin Eduardo [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil)

    2016-07-01

    Full text: The recent discovery of high-T{sub C} superconductivity on Fe-based intermetallic materials has motivated an extensive research in this area due to the rich phase diagrams that they present. The non-doped AFe{sub 2}As{sub 2} compounds (named A122) are oxygen free iron arsenides (with A= Ba, Sr, Ca, Eu). At room temperature they are paramagnetic and crystallize in a tetragonal structure. At low temperature they exhibit a spin-density-wave (SDW) ordering transition (typically 100 K < T{sub SDW} < 200 K), connected with a structural phase transition to an orthorhombic structure. These transitions are reflected as anomalies in the electric resistivity, magnetic susceptibility and specific heat data. Although the pure A122 compounds are not superconductors, in these systems, it was observed that the SDW phase can be destabilized through chemical substitution or external applied pressure, leading to the emergence of superconductivity. In particular, the atomic substitution of the alkali atoms with different ionic radii in the A site results in a change of the cell parameters and, consequently, these systems experience effects of chemical pressure. In this context, it is of great interest to investigate the role of the local distortion on the Fe-As bonds for temperatures above and below T{sub SDW}, as the Fe-As bond distance controls directly the chemical pressure on Fe and ultimately the orbital differentiation of the Fe 3d bands on the Fermi Surface of these compounds. Extended X-ray absorption fine structure (EXAFS) measurements are ideal to obtain information about the relationship between local structural distortions and the system spin dynamics. In this work we present a study of the As local environment in AFe{sub 2}As{sub 2} (for A=Eu, Sr, Ba) as a function of temperature through EXAFS measurements in the As K absorption edge. We have investigated the effects of each particular A-site ion on the Fe-As bond from a local point of view. In all cases, high

  15. Preoperative nuclear scans in patients with melanoma

    International Nuclear Information System (INIS)

    Au, F.C.; Maier, W.P.; Malmud, L.S.; Goldman, L.I.; Clark, W.H. Jr.

    1984-01-01

    One hundred forty-one liver scans, 137 brain scans, and 112 bone scans were performed in 192 patients with clinical Stage 1 melanoma. One liver scan was interpreted as abnormal; liver biopsy of that patient showed no metastasis. There were 11 suggestive liver scans; three of the patients with suggestive liver scans had negative liver biopsies. The remaining eight patients were followed from 4 to 6 years and none of those patients developed clinical evidence of hepatic metastases. All of the brain scans were normal. Five patients had suggestive bone scans and none of those patients had manifested symptoms of osseous metastases with a follow-up of 2 to 4.5 years. This study demonstrates that the use of preoperative liver, brain and bone scan in the evaluation of patients with clinical Stage 1 melanoma is virtually unproductive

  16. ABS: Sequence alignment by scanning

    KAUST Repository

    Bonny, Mohamed Talal

    2011-08-01

    Sequence alignment is an essential tool in almost any computational biology research. It processes large database sequences and considered to be high consumers of computation time. Heuristic algorithms are used to get approximate but fast results. We introduce fast alignment algorithm, called Alignment By Scanning (ABS), to provide an approximate alignment of two DNA sequences. We compare our algorithm with the well-known alignment algorithms, the FASTA (which is heuristic) and the \\'Needleman-Wunsch\\' (which is optimal). The proposed algorithm achieves up to 76% enhancement in alignment score when it is compared with the FASTA Algorithm. The evaluations are conducted using different lengths of DNA sequences. © 2011 IEEE.

  17. ABS: Sequence alignment by scanning

    KAUST Repository

    Bonny, Mohamed Talal; Salama, Khaled N.

    2011-01-01

    Sequence alignment is an essential tool in almost any computational biology research. It processes large database sequences and considered to be high consumers of computation time. Heuristic algorithms are used to get approximate but fast results. We introduce fast alignment algorithm, called Alignment By Scanning (ABS), to provide an approximate alignment of two DNA sequences. We compare our algorithm with the well-known alignment algorithms, the FASTA (which is heuristic) and the 'Needleman-Wunsch' (which is optimal). The proposed algorithm achieves up to 76% enhancement in alignment score when it is compared with the FASTA Algorithm. The evaluations are conducted using different lengths of DNA sequences. © 2011 IEEE.

  18. NGA/Insulin receptor scanning

    International Nuclear Information System (INIS)

    Kurtaran, A.; Virgolini, I.

    1994-01-01

    Tc-99m-galactosyl-neoglycoalbumin (NGA) is one of the first receptor-based radiopharmaceuticals which specifically recognizes the hepatic binding protein (HBP) located on the surface of the hepatocytes. The exclusive interactin of NGA with HBP provided the basis for a kinetic model for the evaluation hepatocellular function. During the last years we have used NGA in more than 300 patients with various liver diseases including liver cirrhosis (Stages Child A to Child C), viral hepatitis, and carcinomas. In these studies, the calculated HBP densities, after i.v.-injection of Tc-99m-NGA, significantly correlated with the clinical course of the diseases. Furthermore, similar to conventional Tc-colloid, NGA provided excellent demonstration of 'cold spots' for hepatic masses. In a further approach we used another hepatocyte receptor-seeking radioligand, I-123-Tyr-A14- insulin, and found, that its in vitro-binding to hepatocellular carcinomas is greatly enhanced over normal hepatic tissue. On this basis, we developed a double-tracer method using NGA and insulin in a single study. Thus, areas of 'cold spots' identifying hepatic masses on NGA scans, take up I-123-Tyr-A14-insulin immediately after i.v.-injection. This was true for hepatocellular hepatomas, but not for adenocarcinomas. In conclusion, NGA/insulin receptor scanning could be a novel and save method for the demonstration of hepatocellular hepatomas. (author)

  19. Multifunctional scanning ion conductance microscopy

    Science.gov (United States)

    Page, Ashley; Unwin, Patrick R.

    2017-01-01

    Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential–time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science. PMID:28484332

  20. NGA/Insulin receptor scanning

    Energy Technology Data Exchange (ETDEWEB)

    Kurtaran, A; Virgolini, I [Vienna Univ. (Austria). Abt. fuer Nuklearmedizin; Angelberger, P [Ludwig Boltzmann-Institut fuer Nuklearmedizin, Vienna (Austria)

    1994-10-01

    Tc-99m-galactosyl-neoglycoalbumin (NGA) is one of the first receptor-based radiopharmaceuticals which specifically recognizes the hepatic binding protein (HBP) located on the surface of the hepatocytes. The exclusive interactin of NGA with HBP provided the basis for a kinetic model for the evaluation hepatocellular function. During the last years we have used NGA in more than 300 patients with various liver diseases including liver cirrhosis (Stages Child A to Child C), viral hepatitis, and carcinomas. In these studies, the calculated HBP densities, after i.v.-injection of Tc-99m-NGA, significantly correlated with the clinical course of the diseases. Furthermore, similar to conventional Tc-colloid, NGA provided excellent demonstration of `cold spots` for hepatic masses. In a further approach we used another hepatocyte receptor-seeking radioligand, I-123-Tyr-A14- insulin, and found, that its in vitro-binding to hepatocellular carcinomas is greatly enhanced over normal hepatic tissue. On this basis, we developed a double-tracer method using NGA and insulin in a single study. Thus, areas of `cold spots` identifying hepatic masses on NGA scans, take up I-123-Tyr-A14-insulin immediately after i.v.-injection. This was true for hepatocellular hepatomas, but not for adenocarcinomas. In conclusion, NGA/insulin receptor scanning could be a novel and save method for the demonstration of hepatocellular hepatomas. (author).

  1. Isotope scanning for tumor localization

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-09-15

    At the request of the Government of the United Arab Republic, the Agency provided the services of an expert for the establishment in the UAR of a tumor localization program using photoscanning techniques and appropriate radioactive tracers. Photoscanning is a recently developed technique whereby the differences in isotope concentrations are enhanced on the record, and this facilitates the interpretation of the record. A variety of brain tumors were located, using a suitable radioactive tracer (Hg-203 - labelled Neohydrin) obtained from the USA. In some other investigations, processes in the kidney were scanned. Further, radioactive gold was used to demonstrate the normal and pathological spleen and liver and these tests showed various types of space occupying lesions resulting from malignancy and the parasitic infections endemic to the area. While the localization of brain tumors by scanning techniques is extremely useful, it does not always establish the precise extent of the tumor which should be known at the time of surgery. Dr. Bender, therefore, thought it advisable to instruct personnel in the use of what is known as an in-vivo needle scintillation probe - a technique for the investigation of the isotope concentration in a particular tissue during operation. The necessary instrument was obtained for this purpose and demonstrations were given; one patient was examined in this way at the time of surgery at the University of Alexandria Hospital.

  2. Differential scanning calorimetry of bacteria.

    Science.gov (United States)

    Miles, C A; Mackey, B M; Parsons, S E

    1986-04-01

    Thermograms obtained by differential scanning calorimetry of a range of bacteria of different heat resistances were compared. Equations were derived to calculate the rate at which the numbers of viable organisms in a calorimeter decline as the temperature is raised at a constant rate. Vegetative bacteria scanned at 10 degrees C min-1 showed multi-peaked thermograms with four major peaks (denoted m, n, p and q) occurring in the regions 68-73, 77-84, 89-99 and 105-110 degrees C respectively. Exceptions were that peak m (the largest peak) occurred at 79-82 degrees C in Bacillus stearothermophilus and an additional peak, r, was detected in Escherichia coli at 119 degrees C. At temperatures below the main peak m there were major differences in thermograms between species. There was a direct relationship between the onset of thermal denaturation and the thermoresistance of different organisms. Heat-sensitive organisms displayed thermogram features which were absent in the more heat-resistant types. When samples were cooled to 5 degrees C and re-heated, a small endothermic peak, pr, was observed at the same temperature as p. Peaks p and pr were identified as the melting endotherms of DNA. In all vegetative organisms examined, maximum death rates, computed from published D and z values, occurred at temperatures above the onset of thermal denaturation, i.e. cell death and irreversible denaturation of cell components occurred within the same temperature range.

  3. X-ray absorption edges and E.X.A.F.S.: application to the study of electronic and atomic structures of titanium and vanadium carbides TiC(1-x) and VC(1-x)

    International Nuclear Information System (INIS)

    Moisy-Maurice, Virginie.

    1980-09-01

    This text presents a systematic study of the X-ray absorption fine structures evolution, at the K edge of titanium, with vacancy concentration in TiC(1-x). The absorption edges are situated in the 50 eV following the coefficient discontinuity: from the evaluation of their general aspect, it is deduced that the positive charge of titanium atoms decreases when vacancy concentration increases in TiC(1-x). This allowed us to determine the best band structure calculation model. The interpretation of EXAFS spectra (modulation of the absorption coefficient until 1500 eV above the edge) gives indications about the local atomic structure. Here, the contraction of the average titanium-carbon interatomic distances compared to the distances between crystallographic sites is of the order of the experimental resolution 0.02 A for Ti C(0.8). The study of the damping of the spectra in terms of Debye-Waller factors gave an evaluation of the relative static atomic mean square displacements between first neighbours. Last, it has been established that the disordering of vacancies in the order-disorder transition of V 8 C 7 is an atomic scale phenomenon [fr

  4. Phase diagram and EXAFS study of La sub 0 sub . sub 7 Ca sub 0 sub . sub 3 sub - sub x Ba sub x MnO sub 3 manganites

    CERN Document Server

    Ulyanov, A N; Yang, D S

    2003-01-01

    The phase diagram and local structure of La sub 0 sub . sub 7 Ca sub 0 sub . sub 3 sub - sub x Ba sub x MnO sub 3 (x=0; 0.03; 0.06; ... 0.3) lanthanum manganites were studies. The Curie temperature, T sub c , of the compositions showed a sharp change near the concentrational structural orthorhombic-rhombohedral phase transition. Maximums of dispersion, sigma sub M sub n sub - sub O sup 2 , and asymmetry, sigma M sub n sub - sub O sup 3 , of pair distribution function for the Mn-O bond distances of MnO sub 6 octahedron on x-dependence were observed by extended X-ray absorption fine structure (EXAFS) analysis. The maximum of sigma sub M sub n sub - sub O sup 2 is caused by increase of dynamic rms displacements of Mn-O bond distances near the T sub c. The observed x dependence of sigma sub M sub n sub - sub O sup 3 reflects the reduction of charge carriers mobility at approaching to T sub c. (author)

  5. Local structural changes in paramagnetic and charge-ordered phases of Sm0.2Pr0.3Sr0.5MnO3: an EXAFS study

    International Nuclear Information System (INIS)

    Priolkar, K R; Kulkarni, Vishwajeet; Sarode, P R; Emura, S

    2008-01-01

    Sm 0.5-x Pr x Sr 0.5 MnO 3 exhibits a variety of ground states as x is varied from 0 to 0.5. At an intermediate doping of x = 0.3 a charge-ordered CE-type antiferromagnetic insulating (AFI) ground state is seen. The transition to this ground state is from a paramagnetic-insulating (PMI) phase through a ferromagnetic-metallic phase (FMM). Local structures in PMI and AFI phases of the x = 0.3 sample have been investigated using Pr K-edge and Sm K-edge extended x-ray absorption fine structure (EXAFS). It can be seen that the tilting and rotation of the MnO 6 octahedra about the b-axis are responsible for the charge-ordered CE-type antiferromagnetic ground state at low temperatures. In addition a shift in the position of the rare-earth ion along the c-axis has to be considered to account for observed distribution of bond distances around the rare-earth ion

  6. Mouse manipulation through single-switch scanning.

    Science.gov (United States)

    Blackstien-Adler, Susie; Shein, Fraser; Quintal, Janet; Birch, Shae; Weiss, Patrice L Tamar

    2004-01-01

    Given the current extensive reliance on the graphical user interface, independent access to computer software requires that users be able to manipulate a pointing device of some type (e.g., mouse, trackball) or be able to emulate a mouse by some other means (e.g., scanning). The purpose of the present study was to identify one or more optimal single-switch scanning mouse emulation strategies. Four alternative scanning strategies (continuous Cartesian, discrete Cartesian, rotational, and hybrid quadrant/continuous Cartesian) were selected for testing based on current market availability as well as on theoretical considerations of their potential speed and accuracy. Each strategy was evaluated using a repeated measures study design by means of a test program that permitted mouse emulation via any one of four scanning strategies in a motivating environment; response speed and accuracy could be automatically recorded and considered in view of the motor, cognitive, and perceptual demands of each scanning strategy. Ten individuals whose disabilities required them to operate a computer via single-switch scanning participated in the study. Results indicated that Cartesian scanning was the preferred and most effective scanning strategy. There were no significant differences between results from the Continuous Cartesian and Discrete Cartesian scanning strategies. Rotational scanning was quite slow with respect to the other strategies, although it was equally accurate. Hybrid Quadrant scanning improved access time but at the cost of fewer correct selections. These results demonstrated the importance of testing and comparing alternate single-switch scanning strategies.

  7. Radionuclide scan findings in delayed splenic rupture

    International Nuclear Information System (INIS)

    Flickinger, F.W.; Jackson, G.L.

    1978-01-01

    An initial liver/spleen scan performed on a patient with blunt abdominal trauma was negative 3 days following the accident. A follow-up scan 7 days later showed definite evidence of splenic rupture, proved surgically. The authors conclude that, in such cases, spleen scans may be negative initially because of delayed splenic ruptures

  8. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data ...

  9. Scanning laser polarimetry in glaucoma.

    Science.gov (United States)

    Dada, Tanuj; Sharma, Reetika; Angmo, Dewang; Sinha, Gautam; Bhartiya, Shibal; Mishra, Sanjay K; Panda, Anita; Sihota, Ramanjit

    2014-11-01

    Glaucoma is an acquired progressive optic neuropathy which is characterized by changes in the optic nerve head and retinal nerve fiber layer (RNFL). White-on-white perimetry is the gold standard for the diagnosis of glaucoma. However, it can detect defects in the visual field only after the loss of as many as 40% of the ganglion cells. Hence, the measurement of RNFL thickness has come up. Optical coherence tomography and scanning laser polarimetry (SLP) are the techniques that utilize the evaluation of RNFL for the evaluation of glaucoma. SLP provides RNFL thickness measurements based upon the birefringence of the retinal ganglion cell axons. We have reviewed the published literature on the use of SLP in glaucoma. This review elucidates the technological principles, recent developments and the role of SLP in the diagnosis and monitoring of glaucomatous optic neuropathy, in the light of scientific evidence so far.

  10. QUANTITATIVE CONFOCAL LASER SCANNING MICROSCOPY

    Directory of Open Access Journals (Sweden)

    Merete Krog Raarup

    2011-05-01

    Full Text Available This paper discusses recent advances in confocal laser scanning microscopy (CLSM for imaging of 3D structure as well as quantitative characterization of biomolecular interactions and diffusion behaviour by means of one- and two-photon excitation. The use of CLSM for improved stereological length estimation in thick (up to 0.5 mm tissue is proposed. The techniques of FRET (Fluorescence Resonance Energy Transfer, FLIM (Fluorescence Lifetime Imaging Microscopy, FCS (Fluorescence Correlation Spectroscopy and FRAP (Fluorescence Recovery After Photobleaching are introduced and their applicability for quantitative imaging of biomolecular (co-localization and trafficking in live cells described. The advantage of two-photon versus one-photon excitation in relation to these techniques is discussed.

  11. Radiopharmaceutical agents for skeletal scanning

    International Nuclear Information System (INIS)

    Jansen, S.E.; Van Aswegen, A.; Loetter, M.G.; Minnaar, P.C.; Otto, A.C.; Goedhals, L.; Dedekind, P.S.

    1987-01-01

    The quality of bone scan images obtained with a locally produced and with an imported radiopharmaceutical bone agent, methylene diphosphonate (MDP), was compared visually. Standard skeletal imaging was carried out on 10 patients using both agents, with a period of 2 to 7 days between studies with alternate agents. Equal amounts of activity were administered for both agents. All images were acquired on Polaroid film for subsequent evaluation. The acquisition time for standard amount of counts per study was recorded. Three physicians with applicable experience evaluated image quality (on a 4 point scale) and detectability of metastasis (on a 3 point scale). There was no statistically significant difference (p 0,05) between the two agents by paired t-test of Hotelling's T 2 analysis. It is concluded that the imaging properties of the locally produced and the imported MDP are similar

  12. A fluorescence scanning electron microscope

    International Nuclear Information System (INIS)

    Kanemaru, Takaaki; Hirata, Kazuho; Takasu, Shin-ichi; Isobe, Shin-ichiro; Mizuki, Keiji; Mataka, Shuntaro; Nakamura, Kei-ichiro

    2009-01-01

    Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM) and an electron microscope (EM). In the current study, a scanning electron microscope (SEM) (JEOL JXA8600 M) was combined with a fluorescence digital camera microscope unit and this hybrid instrument was named a fluorescence SEM (FL-SEM). In the labeling of FL-SEM samples, both Fluolid, which is an organic EL dye, and Alexa Fluor, were employed. We successfully demonstrated that the FL-SEM is a simple and practical tool for correlative fluorescence and electron microscopy.

  13. CT scan of pituitary adenomas

    International Nuclear Information System (INIS)

    Sakoda, K.; Mukada, K.; Yonezawa, M.; Matsumura, S.; Yoshimoto, H.; Mori, S.; Uozumi, T.

    1981-01-01

    CT scan is an extremely useful, almost harmless means of diagnosing pituitary adenomas. Growth hormone (GH)-secreting adenomas tend to have higher absorption coefficent in plain CT than the nonfunctioning and prolactin (PRL)-secreting adenomas. The absorption coefficent on contrast-enhanced CT does not identify the specific type of adenoma. Ring-like enhancement was observed in five nonfunctioning and four PRL-secreting adenomas with suprasellar extension, while cystic components were observed in four nonfunctioning and four PRL-secreting adenomas. In three of ten cases of PRL-secreting microadenomas, the site corresponding to the adenoma was not enhanced, whereas the normal pituitary was. A correlation exists between the size of PRL-secreting adenoma and the serum PRL level, but not between the size of GH-secreting adenomas and the serum GH level. (orig.)

  14. The utility of bone scans in rheumatology

    International Nuclear Information System (INIS)

    Duncan, I.; Dorai-Raj, A.; Khoo, K.; Tymans, K.; Brook, A.

    1997-01-01

    Full text: Introduction: Bone scans are the commonest diagnostic imaging services requested by Australian rheumatologists. Medicare figures suggest that an average rheumatologist orders about $50 000 (AUS) of bone scans annually. Aims: To ascertain the reasons why rheumatologists request bone scans and how it affects their patient management. Methods: A two-part prospective survey was administered before and after every bone scan ordered by four rheumatologists over a six-month period in 1996. Results: A total of 136 bone scans were requested (66.2% whole body; 33.8% regional; 6% SPECT). The primary indications for scanning were (1) to confirm a clinical diagnosis (38%); (2) to exclude a diagnosis (34%); (3) to localize site of pain (17%); and (4) to assist in management (6%). The common diseases that rheumatologists were attempting to confirm/exclude with bone scanning were inflammatory arthritis, malignancy, and fracture. However, the commonest provisional and final diagnosis was soft tissue rheumatism (18%) followed by inflammatory arthritis (15%) and osteoarthritis (11%). In 24% of patients with a provisional diagnosis of soft tissue rheumatism the diagnosis was changed by the bone scan. The scan was successful in excluding a diagnosis in 88 per cent where this was the primary indication for the test. It was successful in confirming a diagnosis in 79 per cent where this was the primary indication. In 32 per cent the bone scan altered the clinical diagnosis and in 43 per cent it altered management. The bone scan result prevented further investigations in 60 per cent. Conclusions: The commonest pre-scan and post-scan diagnosis is soft tissue rheumatism. Rheumatologists predominantly request bone scanning to confirm or exclude their clinical suspicion of inflammatory arthritis, malignancy, and fracture. Bone scans were successful in achieving these objectives in at least 79 per cent of cases

  15. Handbook of optical and laser scanning

    CERN Document Server

    Marshall, Gerald F

    2011-01-01

    From its initial publication titled Laser Beam Scanning in 1985 to Handbook of Optical and Laser Scanning, now in its second edition, this reference has kept professionals and students at the forefront of optical scanning technology. Carefully and meticulously updated in each iteration, the book continues to be the most comprehensive scanning resource on the market. It examines the breadth and depth of subtopics in the field from a variety of perspectives. The Second Edition covers: Technologies such as piezoelectric devices Applications of laser scanning such as Ladar (laser radar) Underwater

  16. Bone scanning in severe external otitis

    International Nuclear Information System (INIS)

    Levin, W.J.; Shary, J.H. III; Nichols, L.T.; Lucente, F.E.

    1986-01-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis

  17. Scanning Tunneling Optical Resonance Microscopy

    Science.gov (United States)

    Bailey, Sheila; Wilt, Dave; Raffaelle, Ryne; Gennett, Tom; Tin, Padetha; Lau, Janice; Castro, Stephanie; Jenkins, Philip; Scheiman, Dave

    2003-01-01

    Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically tunneling current

  18. Vacuum scanning capillary photoemission microscopy.

    Science.gov (United States)

    Aseyev, S A; Cherkun, A P; Mironov, B N; Petrunin, V V; Chekalin, S V

    2017-08-01

    We demonstrate the use of a conical capillary in a scanning probe microscopy for surface analysis. The probe can measure photoemission from a substrate by transmitting photoelectrons along the capillary as a function of probe position. The technique is demonstrated on a model substrate consisting of a gold reflecting layer on a compact disc which has been illuminated by an unfocused laser beam with a wavelength 400nm, from a femtosecond laser with a beam size of 4mm. A quartz capillary with a 2-µm aperture has been used in the experiments. The period of gold microstructure, shown to be 1.6µ, was measured by the conical probe operating in shear force mode. In shear force regime, the dielectric capillary has been used as a "classical" SPM tip, which provided images reflecting the surface topology. In a photoelectron regime photoelectrons passed through hollow tip and entered a detector. The spatial distribution of the recorded photoelectrons consisted of periodic mountain-valley strips, resembling the surface profile of the sample. Submicron spatial resolution has been achieved. This approach paves the way to study pulsed photodesorption of large organic molecular ions with high spatial and element resolution using the combination of a hollow-tip scanner with time-of-flight technique. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Monochromated scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Rechberger, W.; Kothleitner, G.; Hofer, F.

    2006-01-01

    Full text: Electron energy-loss spectroscopy (EELS) has developed into an established technique for chemical and structural analysis of thin specimens in the (scanning) transmission electron microscope (S)TEM. The energy resolution in EELS is largely limited by the stability of the high voltage supply, by the resolution of the spectrometer and by the energy spread of the source. To overcome this limitation a Wien filter monochromator was recently introduced with commercially available STEMs, offering the advantage to better resolve EELS fine structures, which contain valuable bonding information. The method of atomic resolution Z-contrast imaging within an STEM, utilizing a high-angle annular dark-field (HAADF) detector can perfectly complement the excellent energy resolution, since EELS spectra can be collected simultaneously. In combination with a monochromator microscope not only high spatial resolution images can be recorded but also high energy resolution EELS spectra are attainable. In this work we investigated the STEM performance of a 200 kV monochromated Tecnai F20 with a high resolution Gatan Imaging Filter (HR-GIF). (author)

  20. Clinical role of skeletal scanning

    Energy Technology Data Exchange (ETDEWEB)

    Ell, P J

    1975-12-01

    Malignant disease very often spreads to the skeleton. This is particularly true for carcinomas of the breast, the lungs, the prostate, and the thyroid. Knowledge of the state of the skeleton in these disorders is therefore desirable since patient management will largely depend on the early detection of bony deposits. Primary bone disease often spreads to soft tissue (lungs), and the early detection of this may alter significantly the therapeutic approach to the primary lesion. Traditionally, x-ray skeletal surveys and serum enzyme measurements provide indices which can be used in the staging of these disorders. Complementary techniques such as mammography, xeroradiography, thermography, and radionuclide imaging have been used to provide further relevant information. A number of benign bone diseases need early assessment in order to institute the best form of treatment. It is of importance to assess the circulation in localized areas of bone and to predict the appearance of avascular necrosis, to understand the healing mechanisms involved in fractures, and to predict the outcome of bone grafting. In this paper the clinical role of bone scanning is reviewed, particular attention being given to the recent advances brought about by the introduction of the /sup 99m/Tc compounds. It is important that the non-specialist should be aware of the great improvement in the results obtained and in the help they can give him in deciding on the best management of each patient as an individual.

  1. Scanning electron microscopy of bone.

    Science.gov (United States)

    Boyde, Alan

    2012-01-01

    This chapter described methods for Scanning Electron Microscopical imaging of bone and bone cells. Backscattered electron (BSE) imaging is by far the most useful in the bone field, followed by secondary electrons (SE) and the energy dispersive X-ray (EDX) analytical modes. This chapter considers preparing and imaging samples of unembedded bone having 3D detail in a 3D surface, topography-free, polished or micromilled, resin-embedded block surfaces, and resin casts of space in bone matrix. The chapter considers methods for fixation, drying, looking at undersides of bone cells, and coating. Maceration with alkaline bacterial pronase, hypochlorite, hydrogen peroxide, and sodium or potassium hydroxide to remove cells and unmineralised matrix is described in detail. Attention is given especially to methods for 3D BSE SEM imaging of bone samples and recommendations for the types of resin embedding of bone for BSE imaging are given. Correlated confocal and SEM imaging of PMMA-embedded bone requires the use of glycerol to coverslip. Cathodoluminescence (CL) mode SEM imaging is an alternative for visualising fluorescent mineralising front labels such as calcein and tetracyclines. Making spatial casts from PMMA or other resin embedded samples is an important use of this material. Correlation with other imaging means, including microradiography and microtomography is important. Shipping wet bone samples between labs is best done in glycerol. Environmental SEM (ESEM, controlled vacuum mode) is valuable in eliminating -"charging" problems which are common with complex, cancellous bone samples.

  2. Observation of Liver Color Scan

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Y K; Ahn, S B [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1969-09-15

    In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permitted a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscesses, 10 hepatitis and other 13 cases of the liver diseases which were clinically and pathologically diagnosed at Severance Hospital, Yonsei Univ. since Feb. 1969 through Sept. 1969. These scintigrams have been analyzed in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1) Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2) Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3) Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4) The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases (74-95% of all diseased livers). 5) The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6) Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape an margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  3. Observation of Liver Color Scan

    International Nuclear Information System (INIS)

    Choe, Y. K.; Ahn, S. B.

    1969-01-01

    In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permitted a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscesses, 10 hepatitis and other 13 cases of the liver diseases which were clinically and pathologically diagnosed at Severance Hospital, Yonsei Univ. since Feb. 1969 through Sept. 1969. These scintigrams have been analyzed in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1) Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2) Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3) Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4) The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases (74-95% of all diseased livers). 5) The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6) Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape an margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  4. EXAFS and FTIR studies of selenite and selenate sorption by alkoxide-free sol–gel generated Mg–Al–CO 3 layered double hydroxide with very labile interlayer anions

    KAUST Repository

    Chubar, Natalia

    2014-01-01

    © the Partner Organisations 2014. Current research on Layered Double Hydroxides (LDHs, also known as hydrotalcites, HTs) is predominantly focused on their intercalations, but the industrial application of LDHs for anion exchange adsorption has not yet been achieved. It was recently recognized that, to develop LDH applications, these materials should be produced using methods other than direct co-precipitation. Mg-Al-CO3LDH produced using an alkoxide-free sol-gel synthesis showed exceptional removal properties for aqueous selenium species. Se K-edge EXAFS/XANES and FTIR studies (supporting the data by XRD patterns) were performed to explain the unusual adsorptive performance of Mg-Al LDH by revealing the molecular-level mechanism of HSeO3 -, SeO4 2-and {HSeO3 -+ SeO4 2-} uptake at pH 5, 7 and 8.5. The role of inner-sphere complexation (exhibited by inorganic adsorbents with good performance) in adsorption of both selenium aqueous species was not confirmed. However, Mg-Al LDH fully met the other expectations regarding the involvement of the interlayer anions. The interlayer carbonate (due to its favorable speciation and generous HT hydration) gave a "second breath" to selenite sorption and was the only mechanism that controlled the removal of Se(vi). Because inner sphere complexation was the leading mechanism for selenite removal, ion exchange via surface OH-and interlayer CO3 2-species was the only mechanism for selenate removal; both of these species were easily bound to Mg-Al LDH (on its surface and gently parked into the interlayer forming a multilayer without violation of the structure of Mg-Al-CO3LDH). This work provides the first theoretical explanation of why it is more difficult to sorb selenate than selenite and which material should be used for this purpose. This journal is

  5. EXAFS and FTIR studies of selenite and selenate sorption by alkoxide-free sol–gel generated Mg–Al–CO 3 layered double hydroxide with very labile interlayer anions

    KAUST Repository

    Chubar, Natalia

    2014-08-08

    © the Partner Organisations 2014. Current research on Layered Double Hydroxides (LDHs, also known as hydrotalcites, HTs) is predominantly focused on their intercalations, but the industrial application of LDHs for anion exchange adsorption has not yet been achieved. It was recently recognized that, to develop LDH applications, these materials should be produced using methods other than direct co-precipitation. Mg-Al-CO3LDH produced using an alkoxide-free sol-gel synthesis showed exceptional removal properties for aqueous selenium species. Se K-edge EXAFS/XANES and FTIR studies (supporting the data by XRD patterns) were performed to explain the unusual adsorptive performance of Mg-Al LDH by revealing the molecular-level mechanism of HSeO3 -, SeO4 2-and {HSeO3 -+ SeO4 2-} uptake at pH 5, 7 and 8.5. The role of inner-sphere complexation (exhibited by inorganic adsorbents with good performance) in adsorption of both selenium aqueous species was not confirmed. However, Mg-Al LDH fully met the other expectations regarding the involvement of the interlayer anions. The interlayer carbonate (due to its favorable speciation and generous HT hydration) gave a "second breath" to selenite sorption and was the only mechanism that controlled the removal of Se(vi). Because inner sphere complexation was the leading mechanism for selenite removal, ion exchange via surface OH-and interlayer CO3 2-species was the only mechanism for selenate removal; both of these species were easily bound to Mg-Al LDH (on its surface and gently parked into the interlayer forming a multilayer without violation of the structure of Mg-Al-CO3LDH). This work provides the first theoretical explanation of why it is more difficult to sorb selenate than selenite and which material should be used for this purpose. This journal is

  6. Data acquisition and control for gamma scanning

    International Nuclear Information System (INIS)

    Barnes, B.K.; Murray, A.S.; Quintana, J.N.

    1980-01-01

    A new computer-based data acquisition and control unit has been installed in the Los Alamos Scientific Laboratory (LASL) system for scanning irradiated reactor fuel pins. The scanning mechanism is controlled by a commercial multichannel analyzer via a CAMAC link with an intelligent crate controller. The scanning and control unit consists of three linked LSI-11 computers. The multitasking capability of the commercial operation system allows control decisions to be based upon currently acquiring data

  7. The use of radionuclides in brain scan

    International Nuclear Information System (INIS)

    Boasquevisque, E.M.

    1979-01-01

    Brain scanning is easy to perform, safe and well tolerated by the patient. It has a high sensitivity, and accuracy (85-90%) in detecting focal lesions with a minimal size of 1.5-2cm, located superior to the brain stem; however, it lacks specificity. It does not compete with other procedures such as CT scan and angiography bit they rather complement one another. The brain scan is useful as a screening exam. (Author) [pt

  8. Towards vortex imaging with scanning tunneling microscope

    International Nuclear Information System (INIS)

    Fuchs, Dan T.

    1994-02-01

    A low temperature, Besocke beetle type scanning tunneling microscope, with a scan range of 10 by 10 microns was built. The scanning tunneling microscope was calibrates for various temperatures and tested on several samples. Gold monolayers evaporated at 400 deg C were resolved and their dynamic behavior observed. Atomic resolution images of graphite were obtained. The scanning tunneling microscope was designed for future applications of vortex imaging in superconductors. The special design considerations for this application are discussed and the physics underlying it reviewed. (author)

  9. Scanning Tunneling Microscope For Use In Vacuum

    Science.gov (United States)

    Abel, Phillip B.

    1993-01-01

    Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

  10. Human Digital Modeling & Hand Scanning Lab

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory incorporates specialized scanning equipment, computer workstations and software applications for the acquisition and analysis of digitized models of...

  11. Status of automated nuclear scanning systems

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; McNeece, J.P.; Ruddy, F.H.

    1983-07-01

    Present day minicomputers and microprocessors enable a range of automation, from partial to total, of tasks once thought beyond approach. The status of three computer controlled systems for quantitative track measurements is reviewed. Two systems, the Hanford optical track scanner (HOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third systems, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Current limitations of these systems for quantitative track scanning are presented. Experimental uncertainties attained with these computer controlled systems are described using results obtained from reactor neutron dosimetry

  12. Getting a CAT Scan (For Kids)

    Medline Plus

    Full Text Available ... A) Staying Safe Videos for Educators Search English Español Getting a CAT Scan (Video) KidsHealth / For Kids / Getting a CAT Scan (Video) Print en español Obtención de una tomografía computada (video) CAT stands ...

  13. A Student-Built Scanning Tunneling Microscope

    Science.gov (United States)

    Ekkens, Tom

    2015-01-01

    Many introductory and nanotechnology textbooks discuss the operation of various microscopes including atomic force (AFM), scanning tunneling (STM), and scanning electron microscopes (SEM). In a nanotechnology laboratory class, students frequently utilize microscopes to obtain data without a thought about the detailed operation of the tool itself.…

  14. Automation of scanning technique by gamma radiation

    International Nuclear Information System (INIS)

    Aamira, Yahya

    2011-01-01

    The gamma scan technique is a nuclear test allowing the analysis of the internal mechanical properties of distillation columns used in petrochemical industries. Such technique is performed manually. So we propose in this work to automate the gamma scan procedure test by using a PLC. In addition, supervision and data acquisition interfaces are proposed.

  15. Spatial scan statistics using elliptic windows

    DEFF Research Database (Denmark)

    Christiansen, Lasse Engbo; Andersen, Jens Strodl; Wegener, Henrik Caspar

    The spatial scan statistic is widely used to search for clusters in epidemiologic data. This paper shows that the usually applied elimination of secondary clusters as implemented in SatScan is sensitive to smooth changes in the shape of the clusters. We present an algorithm for generation of set...

  16. Spatial scan statistics using elliptic windows

    DEFF Research Database (Denmark)

    Christiansen, Lasse Engbo; Andersen, Jens Strodl; Wegener, Henrik Caspar

    2006-01-01

    The spatial scan statistic is widely used to search for clusters. This article shows that the usually applied elimination of secondary clusters as implemented in SatScan is sensitive to smooth changes in the shape of the clusters. We present an algorithm for generation of a set of confocal elliptic...

  17. Security scanning of Web sites at CERN

    CERN Multimedia

    IT Department

    2010-01-01

    As of early 2010, the CERN Computer Security Team will start regular scanning of all Web sites and Web applications at CERN, visible on the Internet, or on the General Purpose Network (office network). The goal of this scanning is to improve the quality of CERN Web sites. All deficits found will be reported by e-mail to the relevant Web site owners, and must be fixed in a timely manner. Web site owners may also request one-off scans of their Web site or Web application, by sending an e-mail to Computer.Security@cern.ch. These Web scans are designed to limit the impact on the scanned Web sites. Nevertheless, in very rare cases scans may cause undesired side-effects, e.g. generate a large number of log entries, or cause particularly badly designed or less robust Web applications to crash. If a Web site is affected by these security scans, it will also be susceptible to any more aggressive scan that can be performed any time by a malicious attacker. Such Web applications should be fixed, and also additionally...

  18. A Scanning Microwave Radar and Radiometer

    DEFF Research Database (Denmark)

    Skou, Niels

    1995-01-01

    The Scanning Microwave Radar and Radiometer (SMRR) is a line scanner featuring a combined radar and radiometer system operating around 35 and 94 GHz. The layout of the SMRR is shown. The 2 offset antenna parabolas scan in synchronism, the receiver antenna has the highest gain in order to ensure...

  19. From Cooperative Scans to Predictive Buffer Management

    NARCIS (Netherlands)

    M. Switakowski; P.A. Boncz (Peter); M. Zukowski (Marcin)

    2012-01-01

    textabstractIn analytical applications, database systems often need to sustain workloads with multiple concurrent scans hitting the same table. The Cooperative Scans (CScans) framework, which introduces an Active Buer Manager (ABM) component into the database architecture, has been the most

  20. Scanning Capacitance Microscopy | Materials Science | NREL

    Science.gov (United States)

    obtained using scanning capacitance microscopy. Top Right: Image of p-type and n-type material, obtained 'fingers' of light-colored n-type material on a yellow and blue background representing p-type material material, obtained using scanning capacitance microscopy, in a sample semiconductor device; the image shows

  1. Getting a CAT Scan (For Kids)

    Medline Plus

    Full Text Available ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Español Getting a CAT Scan (Video) KidsHealth / For Kids / Getting a CAT Scan (Video) Print en español ...

  2. Time-resolved scanning tunnelling microscopy

    NARCIS (Netherlands)

    van Houselt, Arie; Zandvliet, Henricus J.W.

    2010-01-01

    Scanning tunneling microscopy has revolutionized our ability to image, study, and manipulate solid surfaces on the size scale of atoms. One important limitation of the scanning tunneling microscope (STM) is, however, its poor time resolution. Recording a standard image with a STM typically takes

  3. Full cycle rapid scan EPR deconvolution algorithm.

    Science.gov (United States)

    Tseytlin, Mark

    2017-08-01

    Rapid scan electron paramagnetic resonance (RS EPR) is a continuous-wave (CW) method that combines narrowband excitation and broadband detection. Sinusoidal magnetic field scans that span the entire EPR spectrum cause electron spin excitations twice during the scan period. Periodic transient RS signals are digitized and time-averaged. Deconvolution of absorption spectrum from the measured full-cycle signal is an ill-posed problem that does not have a stable solution because the magnetic field passes the same EPR line twice per sinusoidal scan during up- and down-field passages. As a result, RS signals consist of two contributions that need to be separated and postprocessed individually. Deconvolution of either of the contributions is a well-posed problem that has a stable solution. The current version of the RS EPR algorithm solves the separation problem by cutting the full-scan signal into two half-period pieces. This imposes a constraint on the experiment; the EPR signal must completely decay by the end of each half-scan in order to not be truncated. The constraint limits the maximum scan frequency and, therefore, the RS signal-to-noise gain. Faster scans permit the use of higher excitation powers without saturating the spin system, translating into a higher EPR sensitivity. A stable, full-scan algorithm is described in this paper that does not require truncation of the periodic response. This algorithm utilizes the additive property of linear systems: the response to a sum of two inputs is equal the sum of responses to each of the inputs separately. Based on this property, the mathematical model for CW RS EPR can be replaced by that of a sum of two independent full-cycle pulsed field-modulated experiments. In each of these experiments, the excitation power equals to zero during either up- or down-field scan. The full-cycle algorithm permits approaching the upper theoretical scan frequency limit; the transient spin system response must decay within the scan

  4. Scanning tunneling microscope assembly, reactor, and system

    Science.gov (United States)

    Tao, Feng; Salmeron, Miquel; Somorjai, Gabor A

    2014-11-18

    An embodiment of a scanning tunneling microscope (STM) reactor includes a pressure vessel, an STM assembly, and three spring coupling objects. The pressure vessel includes a sealable port, an interior, and an exterior. An embodiment of an STM system includes a vacuum chamber, an STM reactor, and three springs. The three springs couple the STM reactor to the vacuum chamber and are operable to suspend the scanning tunneling microscope reactor within the interior of the vacuum chamber during operation of the STM reactor. An embodiment of an STM assembly includes a coarse displacement arrangement, a piezoelectric fine displacement scanning tube coupled to the coarse displacement arrangement, and a receiver. The piezoelectric fine displacement scanning tube is coupled to the coarse displacement arrangement. The receiver is coupled to the piezoelectric scanning tube and is operable to receive a tip holder, and the tip holder is operable to receive a tip.

  5. Diagnosis of Stomach Carcinoma by Radioisotope Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Czerniak, P.; Meytes, E.; Sinkover, A.; Bank, H. [Tel-Hashomer Government Hospital, University of Tel Aviv School of Medicine (Israel)

    1969-05-15

    Scanning of the stomach after administration of {sup 131}I and {sup 99m}Tc is presented. Experiments on 20 dogs were performed and 105 patients were examined. The studies with {sup 131}I are only mentioned briefly as they have been summarized in a previous publication and we have concentrated on our experience with {sup 99m}Tc and on stomach carcinoma. The turnover of the nuclide in blood, urine, gastric juice and gastric mucosa was tested: in-vivo and post-operative scannings were performed. The scans are classified in four groups. Carcinoma of the stomach results in space-occupying lesions or foggy scans. A correlation of 85 - 90% between scan results and clinical findings is noted. A special group of 10 volunteers was examined to establish the possibility of a screening examination for the detection of stomach cancer using the technique presented. (author)

  6. Significance of leukocyte scanning in infected endoprostheses

    Energy Technology Data Exchange (ETDEWEB)

    Becker, W.; Pasurka, B.; Boerner, W.

    1989-03-01

    31 patients with suspected septic loosening of an endoprosthesis (hip endoprosthesis n=30; knee endoprosthesis n=1) were examined with leukocyte scans (10 MBq /sup 111/In-oxine: n=22; 300 MBq /sup 99m/Tc-HMPAO: n=9). The results were compared with results of the bacterial growth (n=22), the histology (n=12) and of the bone scans (/sup 99m/Tc-MDP: n=20) which were performed within 4 days. The sensitivity of the bone scan was 100%, the specificity 30% and the diagnostic accuracy regarding a septic loosening of the arthroplasty was 55%. For the leukocyte scans a comparable sensitivity of 100%, but a higher specificity (86%) and accuracy (91%) could be calculated. A false positive leukocyte scan could be observed in a periprosthetic granuloma, an ossifying periarthritis and in a patient with negative bacterial growth with the histological proof of an inflammation.

  7. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  8. RubiShort: Reducing scan time in 82Rb heart scans to minimize movements artifacts

    DEFF Research Database (Denmark)

    Madsen, Jeppe; Vraa, Kaspar J.; Harms, Hans

    .013x, R2=0.98; %Reversible: y=1.008x, R2=0.95; TPD: y=1.000x, R2=0.99). Conclusion:, Scan time of myocardial perfusion scans using 82Rb can be reduced from 7 min. to 5 min. without loss of quantitative accuracy. Since patient motion is frequent in the last minutes of the scans, scan time reduction...

  9. Oscillatory Behavior during the Catalytic Partial Oxidation of Methane: Following Dynamic Structural Changes of Palladium Using the QEXAFS Technique

    DEFF Research Database (Denmark)

    Stoetzel, Jan; Frahm, Ronald; Kimmerle, Bertram

    2012-01-01

    oxidation of methane, the catalyst reduced from the end to the beginning of the catalyst bed and oxidized again toward the end as soon as the entire catalyst bed was reduced. On an entirely oxidized catalyst bed, only total oxidation of methane was observed and consumed the oxygen until the conditions...... of the Pd particles at increasing age of the catalyst was observed, which leads to a lower oscillation frequency. Effects of particle size, oven temperature, and oxygen/methane ratio on the oscillation behavior were studied in detail. The deactivation period (reoxidation of Pd) was much less influenced...... by the oven temperature than the ignition behavior of the catalytic partial oxidation of methane. This indicates that deactivation is caused by an autoreduction of the palladium at the beginning of the catalyst bed due to the high temperature achieved by total oxidation of methane....

  10. Gallium-67 citrate scan in extrapulmonary tuberculosis

    International Nuclear Information System (INIS)

    Lin Wanyu

    1999-01-01

    Aim: Whole-body gallium scan was performed to evaluate the usefulness of gallium scan for detecting extrapulmonary tuberculosis (TB) lesions. Methods: Thirty-seven patients with extrapulmonary TB were included in this study. Four patients were found to have two lesions. Totally, 41 lesions were identified, including 19 TB arthritis, 8 spinal TB, 5 TB meningitis, 3 TB lymphadenopathy, 2 TB pericarditis, 1 TB peritonitis, 1 intestinal TB, 1 skin TB and 1 renal TB. Results: Of the 41 extrapulmonary TB lesions, gallium scan detected 32 lesions with a sensitivity of 78%. All the patients with TB meningitis showed negative gallium scan. When the five cases of TB meningitis were excluded, the detection sensitivity of gallium scan increased to 88.9% (32/36). Conclusion: Our data revealed that gallium scan is a convenient and useful method for evaluating extrapulmonary TB lesions other than TB-meningitis. We suggest that gallium scan be included in the clinical routine for patients with suspected extrapulmonary TB. (orig.) [de

  11. Precursor and Neutral Loss Scans in an RF Scanning Linear Quadrupole Ion Trap

    Science.gov (United States)

    Snyder, Dalton T.; Szalwinski, Lucas J.; Schrader, Robert L.; Pirro, Valentina; Hilger, Ryan; Cooks, R. Graham

    2018-03-01

    Methodology for performing precursor and neutral loss scans in an RF scanning linear quadrupole ion trap is described and compared to the unconventional ac frequency scan technique. In the RF scanning variant, precursor ions are mass selectively excited by a fixed frequency resonance excitation signal at low Mathieu q while the RF amplitude is ramped linearly to pass ions through the point of excitation such that the excited ion's m/z varies linearly with time. Ironically, a nonlinear ac frequency scan is still required for ejection of the product ions since their frequencies vary nonlinearly with the linearly varying RF amplitude. In the case of the precursor scan, the ejection frequency must be scanned so that it is fixed on a product ion m/z throughout the RF scan, whereas in the neutral loss scan, it must be scanned to maintain a constant mass offset from the excited precursor ions. Both simultaneous and sequential permutation scans are possible; only the former are demonstrated here. The scans described are performed on a variety of samples using different ionization sources: protonated amphetamine ions generated by nanoelectrospray ionization (nESI), explosives ionized by low-temperature plasma (LTP), and chemical warfare agent simulants sampled from a surface and analyzed with swab touch spray (TS). We lastly conclude that the ac frequency scan variant of these MS/MS scans is preferred due to electronic simplicity. In an accompanying manuscript, we thus describe the implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 using constant RF voltage. [Figure not available: see fulltext.

  12. Bone scanning in patients with breast carcinoma

    International Nuclear Information System (INIS)

    Inoue, Y.; Nishi, T.; Hirose, T.; Schichijo, Y.; Ibukuro, K.

    1985-01-01

    Skeletal imaging using radionuclides has proved to be a sensitive method for the detection of early bony metastases from breast carcinoma. Recent studies have found a relatively low rate of abnormal scans in patients with stage I and II breast cancers, and therefore it is open to question whether bone scanning should be part of the preoperative evaluation of any patient prior to breast surgery. We reviewed our experience with bone scans in 329 patients out of 406 histologically proven breast cancer patients to determine if any or all patients should have this procedure done routinely prior to breast surgery. (orig.) [de

  13. Diagnostic value of the coronary CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1982-01-01

    Using high-resolution computed tomography, coronary scanning has been made to investigate the radiographical details of the middle and inner ear organs. Twenty patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, facial spasm, and suspected meningitis, were evaluated. In 26 of 40 ears in this series, the coronary scans sharply outlined almost all of the bony structures, and showed also the eardrum as a clearly defined soft tissue, but no abnormal radiographical findings were recognized. In the remaining ears with chronic otitis media, the scans were valuable in demonstration of mucosal thickening, granulation tissue, and destruction of the auditory ossicles. (author)

  14. Bone scan in diagnosis of infectious osteoarthritis

    International Nuclear Information System (INIS)

    Marandian, M.H.; Mortazavi, H.; Behvad, A.; Haghigat, H.; Lessani, M.; Youssefian, B.

    1979-01-01

    Bone scan with Technetium 99m is harmless method of evaluation of skeletal lesions. It is safe in pediatrics age group and it can be used in early diagnosis of infectious osteoarthritis. Bone scan differentiate osteomyelitis from cellulitis, and also it may help in diagnosis of subclinical involvement of rheumatoid arthritis, benign and malignant bone tumors, stress fractures and periostitis. We report results of bone scan in 30 pediatrics patients as follow: osteomyelitis 9 cases, cellulitis 4 cases, infectious arthritis 7 cases, tuberculous osteoarthritis 2 cases, rheumatoid arthritis 2 cases, and other different diseases 9 cases [fr

  15. PET scanning in plastic and reconstructive surgery.

    Science.gov (United States)

    Liodaki, Eirini; Eirini, Liodaki; Liodakis, Emmanouil; Emmanouil, Liodakis; Papadopoulos, Othonas; Othonas, Papadopoulos; Machens, Hans-Günther; Hans-Günther, Machens; Papadopulos, Nikolaos A; Nikolaos, Papadopulos A

    2012-02-01

    In this report we highlight the use of PET scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge.

  16. Gamma scanning of the irradiated HANARO fuels

    International Nuclear Information System (INIS)

    Hong, Kwon Pyo; Lee, K. S.; Park, D. G.; Baik, S. Y.; Song, W. S.; Kim, T. Y.; Seo, C. K.

    1997-02-01

    To conform the burnup state of the fuels, we have transported the irradiated HANARO fuels from the reactor to IMEF (Irradiated Material Examination Facility), and executed gamma scanning for the fuels. By measuring the gamma-rays from the irradiated fuels we could see the features of the relative burnup distributions in the fuel bundles. All of 17 fuel bundles were taken in and out between HANARO and IMEF from March till August in 1996, and we carried out the related regulations. Longitudinal gamma scanning and angular gamma scanning are done for each fuel bundle without dismantlement of the bundles. (author). 5 tabs., 25 figs

  17. Confocal scanning microscope for nuclear photoemulsion

    International Nuclear Information System (INIS)

    Batusov, Yu.A.; Kovalev, Yu.S.; Soroko, L.M.

    2005-01-01

    The application of the confocal scanning microscope to the objects in the nuclear photoemulsion is described. An array of 27 microtomograms of single silver grain is shown. The cross sections of the same particle track of diameter 1 μm, detected by means of the confocal scanning microscope with open and annular apertures, are presented. It was shown that the confocal scanning microscope opens indeed new opportunities for the nuclear photoemulsion technique to get previously inaccessible information for physics of the short-living particles

  18. Can we trust mass spectrometry for determination of arsenic peptides in plants: comparison of LC-ICP-MS and LC-ES-MS/ICP-MS with XANES/EXAFS in analysis of Thunbergia alata.

    Science.gov (United States)

    Bluemlein, Katharina; Raab, Andrea; Meharg, Andrew A; Charnock, John M; Feldmann, Jörg

    2008-04-01

    The weakest step in the analytical procedure for speciation analysis is extraction from a biological material into an aqueous solution which undergoes HPLC separation and then simultaneous online detection by elemental and molecular mass spectrometry (ICP-MS/ES-MS). This paper describes a study to determine the speciation of arsenic and, in particular, the arsenite phytochelatin complexes in the root from an ornamental garden plant Thunbergia alata exposed to 1 mg As L(-1) as arsenate. The approach of formic acid extraction followed by HPLC-ES-MS/ICP-MS identified different As(III)-PC complexes in the extract of this plant and made their quantification via sulfur (m/z 32) and arsenic (m/z 75) possible. Although sulfur sensitivity could be significantly increased when xenon was used as collision gas in ICP-qMS, or when HR-ICP-MS was used in medium resolution, the As:S ratio gave misleading results in the identification of As(III)-PC complexes due to the relatively low resolution of the chromatography system in relation to the variety of As-peptides in plants. Hence only the parallel use of ES-MS/ICP-MS was able to prove the occurrence of such arsenite phytochelatin complexes. Between 55 and 64% of the arsenic was bound to the sulfur of peptides mainly as As(III)(PC(2))(2), As(III)(PC(3)) and As(III)(PC(4)). XANES (X-ray absorption near-edge spectroscopy) measurement, using the freshly exposed plant root directly, confirmed that most of the arsenic is trivalent and binds to S of peptides (53% As-S) while 38% occurred as arsenite and only 9% unchanged as arsenate. EXAFS data confirmed that As-S and As-O bonds occur in the plants. This study confirms, for the first time, that As-peptides can be extracted by formic acid and chromatographically separated on a reversed-phase column without significant decomposition or de-novo synthesis during the extraction step.

  19. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans.

    Science.gov (United States)

    Chen, Xu; Guo, Tengfei; Hou, Yubin; Zhang, Jing; Meng, Wenjie; Lu, Qingyou

    2017-01-01

    A new scan-head structure for the scanning tunneling microscope (STM) is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans) coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan). They are fixed at one end (called common end). A hollow tantalum shaft is coaxially housed in the XY -scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  20. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans

    Directory of Open Access Journals (Sweden)

    Xu Chen

    2017-01-01

    Full Text Available A new scan-head structure for the scanning tunneling microscope (STM is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan. They are fixed at one end (called common end. A hollow tantalum shaft is coaxially housed in the XY-scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  1. Bone scan and joint scan of hands and feet in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Carpentier, N.; Verbeke, S.; Perdrisot, R.; Grilo, R.M.; Quenesson, E.; Bonnet, C.; Vergne, P.; Treves, R.; Bertin, P.; Boutros-Toni, F.

    2000-01-01

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate 99m Tc intravenous injection. Patients were scanned 5 minutes (tissual time, T t ) and 3 hours 1/4 (bone time, T 0 ) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of 99m Tc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T 0 . The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)

  2. The utility of repeat sestamibi scans in patients with primary hyperparathyroidism after an initial negative scan.

    Science.gov (United States)

    Krishnamurthy, Vikram D; Sound, Sara; Okoh, Alexis K; Yazici, Pinar; Yigitbas, Hakan; Neumann, Donald; Doshi, Krupa; Berber, Eren

    2017-06-01

    We analyzed the utility of repeated sestambi scans in patients with primary hyperparathyroidism and its effects on operative referral. We carried out a retrospective review of patients with primary hyperparathyroidism who underwent repeated sestambi scans exclusively within our health system between 1996-2015. Patient demographic, presentation, laboratory, imaging, operative, and pathologic data were reviewed. Univariate analysis with JMP Pro v12 was used to identify factors associated with conversion from an initial negative to a subsequent positive scan. After exclusion criteria (including reoperations), we identified 49 patients in whom 59% (n = 29) of subsequent scans remained negative and 41% (n = 20) converted to positive. Factors associated with an initial negative to a subsequent positive scan included classic presentation and second scans with iodine subtraction (P = .04). Nonsurgeons were less likely to order an iodine-subtraction scan (P < .05). Fewer patients with negative imaging were referred to surgery (33% vs 100%, P = .005), and median time to operation after the first negative scan was 25 months (range 1.4-119). Surgeon-performed ultrasonography had greater sensitivity and positive predictive value than repeated sestamibi scans. Negative sestambi scans decreased and delayed operative referral. Consequently, we identified several process improvement initiatives, including education regarding superior institutional imaging. Combining all findings, we created an algorithm for evaluating patients with primary hyperparathyroidism after initially negative sestamibi scans, which incorporates surgeon-performed ultrasonography. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Transverse scan-field imaging apparatus

    International Nuclear Information System (INIS)

    Lyons, F.T.

    1978-01-01

    A description is given of an array of opposed pairs of radiation detectors which could be used in tomography or scintiscanning. The opposed detectors scan in opposite tangential directions in a pre-programmed fashion. The associated control system receives the detector outputs into a buffer store and also provides an address for each element of information detected. The addresses are such that information from one buffer store is read into the RAM of a central processing unit in the opposite direction to that from the store associated with the opposite detector, thus effectively reversing the scan direction of one detector of each pair. Also described are the detectors themselves with focussed collimators, the scan drive mechanism, and the method of calculating radioactive emission intensity at discrete points throughout the scan-field. (author)

  4. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  5. Technical errors in planar bone scanning.

    Science.gov (United States)

    Naddaf, Sleiman Y; Collier, B David; Elgazzar, Abdelhamid H; Khalil, Magdy M

    2004-09-01

    Optimal technique for planar bone scanning improves image quality, which in turn improves diagnostic efficacy. Because planar bone scanning is one of the most frequently performed nuclear medicine examinations, maintaining high standards for this examination is a daily concern for most nuclear medicine departments. Although some problems such as patient motion are frequently encountered, the degraded images produced by many other deviations from optimal technique are rarely seen in clinical practice and therefore may be difficult to recognize. The objectives of this article are to list optimal techniques for 3-phase and whole-body bone scanning, to describe and illustrate a selection of deviations from these optimal techniques for planar bone scanning, and to explain how to minimize or avoid such technical errors.

  6. Getting a CAT Scan (For Kids)

    Medline Plus

    Full Text Available ... site Sitio para adolescentes Body Mind Sexual Health Food & ... stands for "computerized axial tomography." Translated, that means a scanner takes computer pictures of what's going on inside your body. The scan itself ...

  7. Performance of the SRRC scanning photoelectron microscope

    Science.gov (United States)

    Hong, I.-H.; Lee, T.-H.; Yin, G.-C.; Wei, D.-H.; Juang, J.-M.; Dann, T.-E.; Klauser, R.; Chuang, T. J.; Chen, C. T.; Tsang, K.-L.

    2001-07-01

    A scanning photoelectron microscope has been constructed at SRRC. This SPEM system consists primarily of a Fresnel zone plate (ZP) with an order-selection aperture, a flexure scanning stage, a hemispherical electron analyzer, and sample/ZP insertion system. The flexure stage is used to scan the sample. A hemispherical analyzer with Omni V lens and a 16-channel multichannel detector (MCD) is used to collect photoelectrons. A set of 16 photoelectron images at different kinetic energies can be simultaneously acquired in one single scan. The data acquisition system is designed to collect up to 32 images concurrently, including 16 MCD signals, total electron yield and transmitted photon flux. The design and some initial test results of this SPEM station are presented and discussed.

  8. Performance of the SRRC scanning photoelectron microscope

    International Nuclear Information System (INIS)

    Hong, I.-H.; Lee, T.-H.; Yin, G.-C.; Wei, D.-H.; Juang, J.-M.; Dann, T.-E.; Klauser, R.; Chuang, T.J.; Chen, C.T.; Tsang, K.-L.

    2001-01-01

    A scanning photoelectron microscope has been constructed at SRRC. This SPEM system consists primarily of a Fresnel zone plate (ZP) with an order-selection aperture, a flexure scanning stage, a hemispherical electron analyzer, and sample/ZP insertion system. The flexure stage is used to scan the sample. A hemispherical analyzer with Omni V lens and a 16-channel multichannel detector (MCD) is used to collect photoelectrons. A set of 16 photoelectron images at different kinetic energies can be simultaneously acquired in one single scan. The data acquisition system is designed to collect up to 32 images concurrently, including 16 MCD signals, total electron yield and transmitted photon flux. The design and some initial test results of this SPEM station are presented and discussed

  9. Minimising medically unwarranted computed tomography scans

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    As computed tomography (CT) is such a superb diagnostic tool and individual CT risks are small, whenever a CT scan is clinically warranted, the CT benefit/risk balance is by far in the patient’s favour. However, if a CT scan is not clinically warranted, this balance shifts dramatically. It is likely that at least 25% of CT scans fall into this latter category, in that they could either be replaced with alternative imaging modalities or could be avoided entirely. Use of clinical decision rules for CT usage represents a powerful approach for slowing down the increase in CT usage, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they may not be clinically helpful.

  10. Laser scanning of experimental solar cells

    Science.gov (United States)

    Plunkett, B. C.; Lasswell, P. G.

    1980-01-01

    A description is presented of a laser scanning instrument which makes it possible to display and measure the spatial response of a solar cell. Examples are presented to illustrate the use of generated micrographs in the isolation of flaws and features of the cell. The laser scanner system uses a 4 mW, CW helium-neon laser, operating a wavelength of 0.633 micrometers. The beam is deflected by two mirror galvanometers arranged to scan in orthogonal directions. After being focused on the solar cell by the beam focusing lens, the moving light spot raster scans the specimen. The current output of the photovoltaic device under test, as a function of the scan dot position, can be displayed in several modes. The laser scanner has proved to be a very useful diagnostic tool in optimizing the process design of transparent metal film photovoltaic devices on Zn3P2, a relatively new photovoltaic material.

  11. Electron Beam Scanning in Industrial Applications

    Science.gov (United States)

    Jongen, Yves; Herer, Arnold

    1996-05-01

    Scanned electron beams are used within many industries for applications such as sterilization of medical disposables, crosslinking of wire and cables insulating jackets, polymerization and degradation of resins and biomaterials, modification of semiconductors, coloration of gemstones and glasses, removal of oxides from coal plant flue gasses, and the curing of advanced composites and other molded forms. X-rays generated from scanned electron beams make yet other applications, such as food irradiation, viable. Typical accelerators for these applications range in beam energy from 0.5MeV to 10 MeV, with beam powers between 5 to 500kW and scanning widths between 20 and 300 cm. Since precise control of dose delivery is required in many of these applications, the integration of beam characteristics, product conveyance, and beam scanning mechanisms must be well understood and optimized. Fundamental issues and some case examples are presented.

  12. Multicolor Scanning Laser Imaging in Diabetic Retinopathy.

    Science.gov (United States)

    Ahmad, Mohammad S Z; Carrim, Zia Iqbal

    2017-11-01

    Diabetic retinopathy is a common cause of blindness in individuals younger than 60 years. Screening for retinopathy is undertaken using conventional color fundus photography and relies on the identification of hemorrhages, vascular abnormalities, exudates, and cotton-wool spots. These can sometimes be difficult to identify. Multicolor scanning laser imaging, a new imaging modality, may have a role in improving screening outcomes, as well as facilitating treatment decisions. Observational case series comprising two patients with known diabetes who were referred for further examination after color fundus photography revealed abnormal findings. Multicolor scanning laser imaging was undertaken. Features of retinal disease from each modality were compared. Multicolor scanning laser imaging provides superior visualization of retinal anatomy and pathology, thereby facilitating risk stratification and treatment decisions. Multicolor scanning laser imaging is a novel imaging technique offering the potential for improving the reliability of screening for diabetic retinopathy. Validation studies are warranted.

  13. Performance of the SRRC scanning photoelectron microscope

    CERN Document Server

    Hong, I H; Yin, G C; Wei, D H; Juang, J M; Dann, T E; Klauser, R; Chuang, T J; Chen, C T; Tsang, K L

    2001-01-01

    A scanning photoelectron microscope has been constructed at SRRC. This SPEM system consists primarily of a Fresnel zone plate (ZP) with an order-selection aperture, a flexure scanning stage, a hemispherical electron analyzer, and sample/ZP insertion system. The flexure stage is used to scan the sample. A hemispherical analyzer with Omni V lens and a 16-channel multichannel detector (MCD) is used to collect photoelectrons. A set of 16 photoelectron images at different kinetic energies can be simultaneously acquired in one single scan. The data acquisition system is designed to collect up to 32 images concurrently, including 16 MCD signals, total electron yield and transmitted photon flux. The design and some initial test results of this SPEM station are presented and discussed.

  14. Scanning probe lithography for nanoimprinting mould fabrication

    International Nuclear Information System (INIS)

    Luo Gang; Xie Guoyong; Zhang Yongyi; Zhang Guoming; Zhang Yingying; Carlberg, Patrick; Zhu Tao; Liu Zhongfan

    2006-01-01

    We propose a rational fabrication method for nanoimprinting moulds by scanning probe lithography. By wet chemical etching, different kinds of moulds are realized on Si(110) and Si(100) surfaces according to the Si crystalline orientation. The structures have line widths of about 200 nm with a high aspect ratio. By reactive ion etching, moulds with patterns free from the limitation of Si crystalline orientation are also obtained. With closed-loop scan control of a scanning probe microscope, the length of patterned lines is more than 100 μm by integrating several steps of patterning. The fabrication process is optimized in order to produce a mould pattern with a line width about 10 nm. The structures on the mould are further duplicated into PMMA resists through the nanoimprinting process. The method of combining scanning probe lithography with wet chemical etching or reactive ion etching (RIE) provides a resistless route for the fabrication of nanoimprinting moulds

  15. Study of 67Ga scan in sarcoidosis

    International Nuclear Information System (INIS)

    Han Lijun; Qu Wanyin; Liu Xiuqin

    1997-01-01

    Gallium scan and serum angiotensin-converting enzyme assay (SACE) were compared in patients with sarcoidosis. The examination of 67 Ga scan, SACE determination, pulmonary function test, chest CT and chest X-ray in 24 cases with sarcoidosis were studied. The results revealed that 4 of 24 cases had obviously high uptake of 67 Ga exceeding hepatic activity (3+) in clinical active stage, 3 patients had resembling the Greek letter lambda, symmetrically located in bilateral hilar lymph nodes, and among them two had an uptake of 67 Ga in the bilateral lacrimal and parotid gland simulating 'Panda Face'. 8 of 20 cases with inactive sarcoidosis had an abnormal 67 Ga scan (1+). In those patients with normal SACE level but increased uptake of 67 Ga, active stage of disease was demonstrated and steroid therapy was indicated. Gallium scan is a valuable method for the staging of its activity and evaluation of the therapeutic effect in the follow-up patients with sarcoidosis

  16. Magnetic scanning of LWR fuel assemblies

    International Nuclear Information System (INIS)

    Fiarman, S.; Moodenbaugh, A.

    1980-01-01

    Nondestructive assay (NDA) techniques are available both for fresh and spent fuel, but generally are too time consuming and do not uniquely identify an assembly. A new method is reported to obtain a signature from a magnetic scan of each assembly. This scan is an NDA technique that detects magnetic inclusions. It is potentially fast (5 min/assembly), and may provide a unique signature from the magnetic properties of each fuel assembly

  17. Admittance Scanning for Whole Column Detection.

    Science.gov (United States)

    Stamos, Brian N; Dasgupta, Purnendu K; Ohira, Shin-Ichi

    2017-07-05

    Whole column detection (WCD) is as old as chromatography itself. WCD requires an ability to interrogate column contents from the outside. Other than the obvious case of optical detection through a transparent column, admittance (often termed contactless conductance) measurements can also sense changes in the column contents (especially ionic content) from the outside without galvanic contact with the solution. We propose here electromechanically scanned admittance imaging and apply this to open tubular (OT) chromatography. The detector scans across the column; the length resolution depends on the scanning velocity and the data acquisition frequency, ultimately limited by the physical step resolution (40 μm in the present setup). Precision equal to this step resolution was observed for locating an interface between two immiscible liquids inside a 21 μm capillary. Mechanically, the maximum scanning speed was 100 mm/s, but at 1 kHz sampling rate and a time constant of 25 ms, the highest practical scan speed (no peak distortion) was 28 mm/s. At scanning speeds of 0, 4, and 28 mm/s, the S/N for 180 pL (zone length of 1.9 mm in a 11 μm i.d. column) of 500 μM KCl injected into water was 6450, 3850, and 1500, respectively. To facilitate constant and reproducible contact with the column regardless of minor variations in outer diameter, a double quadrupole electrode system was developed. Columns of significant length (>1 m) can be readily scanned. We demonstrate its applicability with both OT and commercial packed columns and explore uniformity of retention along a column, increasing S/N by stopped-flow repeat scans, etc. as unique applications.

  18. An image scanning device using radiating energy

    International Nuclear Information System (INIS)

    Jacob, Daniel.

    1976-01-01

    Said invention relates to an image scanning device using radiating energy. More particularly, it relates to a device for generating a scanning beam of rectangular cross section from a γ or X-ray source. Said invention can be applied to radiographic units of the 'microdose' type used by airline staffs and others for the fast efficient inspection of luggage and parcels in view of detecting hidden things [fr

  19. Thalassemia paravertebral tumors and bone marrow scan

    International Nuclear Information System (INIS)

    Huglo, D.; Rose, C.; Deveaux, M.; Bauters, F.; Marchandise, X.

    1995-01-01

    Two first cousins with thalassemia and with a paravertebral mass had had an indium 111 chloride bone marrow scan. Result of scan influenced therapy: medical treatment in one case where an extramedullary erythropoiesis was confirmed, surgical treatment in the other case. The use of dual-isotope SPECT (indium 111 chloride, HDP -99 Tc) constitutes a contribution to the establishment of diagnosis of extramedullary erythropoiesis, giving to bone marrow scintigraphy a merited importance, avoiding the biopsy. (authors). 15 refs., 5 figs

  20. Linking IMAGE 2 and WORLD SCAN

    International Nuclear Information System (INIS)

    Gelauff, G.; Geurts, B.; Gielen, A.; Den Ouden, A.; Alcamo, J.; Gerlagh, R.

    1995-01-01

    The links between the climate model IMAGE 2 and the economic model WORLD SCAN, which are set up to obtain an integrated scenario instrument for comprehensive and consistent climate-economy scenarios, are presented and discussed. The links are made with respect to energy (in WORLD SCAN) and agriculture (in IMAGE 2), thus providing a consistent linkage with feedbacks running both ways. 2 figs., 1 tab

  1. Computer graphic display of cardiac CT scans

    International Nuclear Information System (INIS)

    Palmer, R.; Carlsson, E.

    1982-01-01

    In order to improve spatial conception and quantitative assessment of the cardiac structures based on cardiac computed tomography, methods for computer graphic display were developed. Excised hearts and living dogs with myocardial infarctions were subjected to CT scanning. The data on the scanner tapes were processed to provide isodensity plots, linear section plots, time-weighted integrated isodensity plots as well as topographical density displays and three-dimensional spatial reconstructions of single and multi-layer scans. (orig.)

  2. Radionuclide bone scanning of medullary chondrosarcoma

    International Nuclear Information System (INIS)

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-01-01

    Technetium-99m methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan intake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the ''extended pattern of uptake'' beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogenous uptake on the scan

  3. Radionuclide bone scanning of medullary chondrosarcoma

    International Nuclear Information System (INIS)

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-01-01

    /sup 99m/Tc methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan uptake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the extended pattern of uptake beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogeneous uptake on the scan

  4. Role of bone scan in rheumatic disease

    International Nuclear Information System (INIS)

    Choi, Yun Young

    2003-01-01

    Rheumatic diseases can be categorized by pathology into several specific types of musculoskeletal problems, including synovitis (e.g. rheumatoid arthritis), enthesopathy (e.g. ankylosing spondylitis) and cartilage degeneration (e.g. osteoarthritis). Skeletal radiographs have contributed to the diagnosis of these articular diseases, and some disease entities need typical radiographic changes as a factor of the diagnostic criteria. However, they sometimes show normal radiographic findings in the early stage of disease, when there is demineralization of less than 30-50%. Bone scans have also been used in arthritis, but not widely because the findings are nonspecific and it is thought that bone scans do not add significant information to routine radiography. Bone scans do however play a different role than simple radiography, and it is a complementary imaging method in the course of management of arthritis. The image quality of bone scans can be improved by obtaining regional views and images under al pin-hole collimator, and through a variety of scintigraphic techniques including the three phase bone scan and bone SPECT. Therefore, bone scans could improve the diagnostic value, and answer multiple clinical questions, based on the pathophysiology of various forms of arthritis

  5. Precision controlled atomic resolution scanning transmission electron microscopy using spiral scan pathways

    Science.gov (United States)

    Sang, Xiahan; Lupini, Andrew R.; Ding, Jilai; Kalinin, Sergei V.; Jesse, Stephen; Unocic, Raymond R.

    2017-03-01

    Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviations, i.e. image distortions, we use spiral scanning paths, allowing precise control of a sub-Å sized electron probe within an aberration-corrected STEM. Although spiral scanning avoids the sudden changes in the beam location (fly-back distortion) present in conventional raster scans, it is not distortion-free. “Archimedean” spirals, with a constant angular frequency within each scan, are used to determine the characteristic response at different frequencies. We then show that such characteristic functions can be used to correct image distortions present in more complicated constant linear velocity spirals, where the frequency varies within each scan. Through the combined application of constant linear velocity scanning and beam path corrections, spiral scan images are shown to exhibit less scan distortion than conventional raster scan images. The methodology presented here will be useful for in situ STEM imaging at higher temporal resolution and for imaging beam sensitive materials.

  6. Detection of Arthritis by Joint Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Maxfield, W. S. [Dept, of Radiology, Louisiana State University School of Medicine, New Orleans, LA (United States); Weiss, T. E.; Tutton, R. H.; Hidalgo, J. U. [Ochsner Clinic and Ochsner Foundation Hospital, New Orleans, LA (United States)

    1969-05-15

    Detection and identification of early arthritis is frequently difficult with routine methods. Several tracers, {sup 131}I human serum albumin (25 {mu}Ci/10 lb), {sup 99m}Tc human serum albumin (1-3 mCi), {sup 131}I iodipamide (40 {mu}Ci/10 lb), and {sup 99m}Tc pertechnetate (10 mCi), have been employed for joint scanning to detect synovitis produced by arthritis in joints of the extremities. When administered intravenously, the 25% increase in localization of these tracers in the synovial membrane, if there is active synovitis, can be demonstrated by scintillation scanning. This ability to detect synovitis at an early stage enables the joint scan to show areas of active synovitis not demonstrated on roentgenograms. The scan may objectively confirm or disprove questionable physical findings. From this standpoint the technique has been useful in determining whether joint pain is functional or due to arthritis as a negative localization tends to rule out active synovitis as the cause of the pain. The scan demonstration of a positive localization of the tracer in several joints when only one area is symptomatic is evidence that joint pain is due to systemic disease. The short half-life tracera permit serial studies to follow the course of an arthritis process. Use of {sup 99m}Tc pertechnetate and an Anger camera have made joint scanning a practical technique for clinical use. A review of the accuracy of joint scanning in 130 cases as compared to roentgenograms is presented. (author)

  7. Special raster scanning for reduction of charging effects in scanning electron microscopy.

    Science.gov (United States)

    Suzuki, Kazuhiko; Oho, Eisaku

    2014-01-01

    A special raster scanning (SRS) method for reduction of charging effects is developed for the field of SEM. Both a conventional fast scan (horizontal direction) and an unusual scan (vertical direction) are adopted for acquiring raw data consisting of many sub-images. These data are converted to a proper SEM image using digital image processing techniques. About sharpness of the image and reduction of charging effects, the SRS is compared with the conventional fast scan (with frame-averaging) and the conventional slow scan. Experimental results show the effectiveness of SRS images. By a successful combination of the proposed scanning method and low accelerating voltage (LV)-SEMs, it is expected that higher-quality SEM images can be more easily acquired by the considerable reduction of charging effects, while maintaining the resolution. © 2013 Wiley Periodicals, Inc.

  8. Scan path entropy and Arrow plots: Capturing scanning behavior of multiple observers

    Directory of Open Access Journals (Sweden)

    Ignace T C Hooge

    2013-12-01

    Full Text Available Designers of visual communication material want their material to attract and retain attention. In marketing research, heat maps, dwell time, and time to AOI first hit are often used as evaluation parameters. Here we present two additional measures 1 scan path entropy to quantify gaze guidance and 2 the arrow plot to visualize the average scan path. Both are based on string representations of scan paths. The latter also incorporates transition matrices and time required for 50% of the observers to first hit AOIs (T50. The new measures were tested in an eye tracking study (48 observers, 39 advertisements. Scan path entropy is a sensible measure for gaze guidance and the new visualization method reveals aspects of the average scan path and gives a better indication in what order global scanning takes place.

  9. Bone scans in nasopharyngeal carcinoma: local experience

    International Nuclear Information System (INIS)

    Tiong, S.

    2004-01-01

    Introduction: Nasopharyngeal carcinoma (NPC) tops the list of malignancy in Malaysia and ranks first in male malignancy in the state of Sarawak. The majority of the NPC patients presented in the advanced stages and often with distal metastasis usually to the bones. In our local hospital is the new practice of bone scan using Tc99 started last year. Over a period of 9 months from July 2003 to March 2004, 41 NPC patients had the bone scans and our experience in these are reviewed and presented. Method: The NPC patients are selected consecutively including both new and treated patients. The scanner used is Siemen E.cam plus and Technecium (Tc99) the radio-active isotope used. The scan images are read and reported by qualified and trained Radiologists. The bone scans are requested from the ENT Specialist of the ENT department of the Hospital. The bone scan reports are checked by the ENT Specialists and the decisions made as to clinical correlation and further definitive imaging studies. Results: 41 NPC patients were included in the studies, 29 newly diagnosed and bone-canned before treatment started and 12 treated of which 3 being diagnosed having recurrent NPC. Of the 29 newly diagnosed patients, one was found true positive bone scan having increased radio-tracer uptake and confirmed Xray imagings. 3 of the treated patients had true positive bone scan with increased radio-tracer uptake and confirmed Xray imagings. Hence a total of 4 out of the 41 patients (9.8%) had bone metastasis on positive bone scans. Of the 29 newly diagnosed patients, 14 were found false positive bone scan having increased radio-tracer uptake but no confirmed X ray imagings. 4 of the treated patients had false positive bone scan with increased radio-tracer uptake but no confirmed X ray imagings. Hence a total of 18 out of the 41 patients (44%) had no bone metastasis on positive bone scans. There were 6 patients with symptoms referable to the bones' distal to the head and 2 had true positive bone

  10. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates.

    Science.gov (United States)

    Zhang, Hao; Li, Xianqi; Chen, Yunmei; Park, Jewook; Li, An-Ping; Zhang, X-G

    2017-01-01

    We present an image postprocessing framework for Scanning Tunneling Microscope (STM) to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a "rubber band" model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA). The numerical results on measurement from copper(111) surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  11. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates

    Directory of Open Access Journals (Sweden)

    Hao Zhang

    2017-01-01

    Full Text Available We present an image postprocessing framework for Scanning Tunneling Microscope (STM to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a “rubber band” model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA. The numerical results on measurement from copper(111 surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  12. Bone scan and red blood cell scan in a patient with epidermal naevus syndrome

    International Nuclear Information System (INIS)

    Becker, W.; Wolf, F.; Stosiek, N.; Peters, K.P.

    1990-01-01

    A bone scan and red blood cell scan in the rare epidermal naevus syndrome, associated with multiple haemangiomes of the bone and hypophosphataemic osteomalacia in a 20-year-old man are reported. The typical pattern of osteomalacia on the bone scan was associated with lesions of increased bone metabolism in the peripheral bones. The haemangiomas did not pool labelled red blood cells. Thus, the bone scan seems to be suited for diagnosing the complete extent of haemangiomas in bone, but they could not be specifically proven by red blood cell pooling. (orig.)

  13. Scanning-time evaluation of Digimarc Barcode

    Science.gov (United States)

    Gerlach, Rebecca; Pinard, Dan; Weaver, Matt; Alattar, Adnan

    2015-03-01

    This paper presents a speed comparison between the use of Digimarc® Barcodes and the Universal Product Code (UPC) for customer checkout at point of sale (POS). The recently introduced Digimarc Barcode promises to increase the speed of scanning packaged goods at POS. When this increase is exploited by workforce optimization systems, the retail industry could potentially save billions of dollars. The Digimarc Barcode is based on Digimarc's watermarking technology, and it is imperceptible, very robust, and does not require any special ink, material, or printing processes. Using an image-based scanner, a checker can quickly scan consumer packaged goods (CPG) embedded with the Digimarc Barcode without the need to reorient the packages with respect to the scanner. Faster scanning of packages saves money and enhances customer satisfaction. It reduces the length of the queues at checkout, reduces the cost of cashier labor, and makes self-checkout more convenient. This paper quantifies the increase in POS scanning rates resulting from the use of the Digimarc Barcode versus the traditional UPC. It explains the testing methodology, describes the experimental setup, and analyzes the obtained results. It concludes that the Digimarc Barcode increases number of items per minute (IPM) scanned at least 50% over traditional UPC.

  14. Human performance in radiological survey scanning

    International Nuclear Information System (INIS)

    Brown, W.S.; Abelquist, E.W.

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments

  15. Scanning laser microscope for imaging nanostructured superconductors

    International Nuclear Information System (INIS)

    Ishida, Takekazu; Arai, Kohei; Akita, Yukio; Miyanari, Mitsunori; Minami, Yusuke; Yotsuya, Tsutomu; Kato, Masaru; Satoh, Kazuo; Uno, Mayumi; Shimakage, Hisashi; Miki, Shigehito; Wang, Zhen

    2010-01-01

    The nanofabrication of superconductors yields various interesting features in superconducting properties. A variety of different imaging techniques have been developed for probing the local superconducting profiles. A scanning pulsed laser microscope has been developed by the combination of the XYZ piezo-driven stages and an optical fiber with an aspheric focusing lens. The scanning laser microscope is used to understand the position-dependent properties of a superconducting MgB 2 stripline of length 100 μm and width of 3 μm under constant bias current. Our results show that the superconducting stripline can clearly be seen in the contour image of the scanning laser microscope on the signal voltage. It is suggested from the observed image that the inhomogeneity is relevant in specifying the operating conditions such as detection efficiency of the sensor.

  16. PET scanning in plastic and reconstructive surgery

    International Nuclear Information System (INIS)

    Eirini, L.; Emmanouil, L.; Othonas, P.; Hans-Guenther, M.; Nikolaos, P.A.

    2012-01-01

    In this report we highlight the use of position emission tomography (PET) scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge. (author)

  17. Scanning probe microscopy experiments in microgravity

    International Nuclear Information System (INIS)

    Drobek, Tanja; Reiter, Michael; Heckl, Wolfgang M.

    2004-01-01

    The scanning probe microscopy setups are small, lightweight and do not require vacuum or high voltage supply. In addition, samples can be investigated directly without further preparation. Therefore, these techniques are well-suited for applications in space, in particular, for operation on the International Space Station (ISS) or for high resolution microscopy on planetary missions. A feasibility study for a scanning tunneling microscopy setup was carried out on a parabolic flight campaign in November 2001 in order to test the technical setup for microgravity applications. With a pocket-size design microscope, a graphite surface was imaged under ambient conditions. Atomic resolution was achieved although the quality of the images was inferior in comparison to laboratory conditions. Improvements for future scanning probe microscopy experiments in microgravity are suggested

  18. The new scanning nuclear microprobe in Uppsala

    International Nuclear Information System (INIS)

    Sunde, T.; Nystroem, J.; Lindh, U.

    1991-01-01

    During 1989/90 a scanning microprobe, developed for 2-4 MeV protons and submicron resolution, is being installed at the EN-tandem accelerator at the The Svedberg Laboratory, Uppsala University, Sweden. The probe-forming units (object diaphragm, aperture diaphragm and triplet of spark-eroded quadrupoles), the scanning unit of current-controlled ferrite cores and a current digitizer are of Oxford design. The other parts are commercial products or are constructed by ourselves. The latter includes the equipment for optical alignment by interference, a feedback-controlled magnetic beam steerer and stabiliser, a fast beam deflector, specially designed mechanical vibration reducers and dedicated AT expansion cards for scanning control and data acquisition. (orig.)

  19. Scanning laser microscope for imaging nanostructured superconductors

    Science.gov (United States)

    Ishida, Takekazu; Arai, Kohei; Akita, Yukio; Miyanari, Mitsunori; Minami, Yusuke; Yotsuya, Tsutomu; Kato, Masaru; Satoh, Kazuo; Uno, Mayumi; Shimakage, Hisashi; Miki, Shigehito; Wang, Zhen

    2010-10-01

    The nanofabrication of superconductors yields various interesting features in superconducting properties. A variety of different imaging techniques have been developed for probing the local superconducting profiles. A scanning pulsed laser microscope has been developed by the combination of the XYZ piezo-driven stages and an optical fiber with an aspheric focusing lens. The scanning laser microscope is used to understand the position-dependent properties of a superconducting MgB 2 stripline of length 100 μm and width of 3 μm under constant bias current. Our results show that the superconducting stripline can clearly be seen in the contour image of the scanning laser microscope on the signal voltage. It is suggested from the observed image that the inhomogeneity is relevant in specifying the operating conditions such as detection efficiency of the sensor.

  20. Cooling system for baby EBM scanning device

    International Nuclear Information System (INIS)

    Abd Halim Baijan; Muhammad Zahidee Taat; Abu Bakar Ghazali; Mohd Rizal Md Chulan; Rokiah Mohd Sabri; Leo Kwee Wah; Mohd Rizal Ibrahim; Lojius Lombigit; Azaman Ahmad

    2009-01-01

    Heat exchange of the scanning window of baby EBM is a critical factor for maintaining the integrity of the window material structure. As the titanium foil which was used as the scanning window, the maximum temperature accepted for the foil should be 200 degree C. This paper will discuss a simple method of Bernoulli principle to obtain the correct air blower capacity in order to reduce the heat of the scanning window of Baby EBM. It was found that the required air pressure and air speed of the blower are 2613.6 Pascal and 237.6 m3/h respectively for the electron accelerator of 0.14 MeV energy and 10 mA beam current. (Author)

  1. Optical vortex scanning inside the Gaussian beam

    International Nuclear Information System (INIS)

    Masajada, J; Leniec, M; Augustyniak, I

    2011-01-01

    We discussed a new scanning method for optical vortex-based scanning microscopy. The optical vortex is introduced into the incident Gaussian beam by a vortex lens. Then the beam with the optical vortex is focused by an objective and illuminates the sample. By changing the position of the vortex lens we can shift the optical vortex position at the sample plane. By adjusting system parameters we can get 30 times smaller shift at the sample plane compared to the vortex lens shift. Moreover, if the range of vortex shifts is smaller than 3% of the beam radius in the sample plane the amplitude and phase distribution around the phase dislocation remains practically unchanged. Thus we can scan the sample topography precisely with an optical vortex

  2. Value of gallbladder B-scan ultrasonography.

    Science.gov (United States)

    Tabrisky, J; Lindstrom, R R; Herman, M W; Castagna, J; Sarti, D

    1975-05-01

    The gallbladder B-scans of 20 patients who had subsequent surgery were separated into three categories based upon certain sonographic criteria. Our data, in this limited series, revealed gallbladder pathology in each patient who had any one or combination of the following scan characteristics: (1) internal echos, (2) irregular wall, or (3) absence of recognizable gallbladder sonolucency. The category which demonstrated a normal sonographic gallbladder, namely a smooth wall and no internal echos, contained a number of false negatives which proved to have either small stone cholelithiasis or extraphepatic ductal obstruction. Within the described limitations, the B-scan can be a valuable test in confirming the significance of a radiographically nonvisualized gallbladder or in detecting a biliary tract lesion in a patient with a disease entity that precludes radiographic visualization by conventional techniques.

  3. Polarized differential-phase laser scanning microscope

    International Nuclear Information System (INIS)

    Chou Chien; Lyu, C.-W.; Peng, L.-C.

    2001-01-01

    A polarized differential-phase laser scanning microscope, which combines a polarized optical heterodyne Mach-Zehnder interferometer and a differential amplifier to scan the topographic image of a surface, is proposed. In the experiment the differential amplifier, which acts as a PM-AM converter, in the experiment, converting phase modulation (PM) into amplitude modulation (AM). Then a novel, to our knowledge, phase demodulator was proposed and implemented for the differential-phase laser scanning microscope. An optical grating (1800 lp/mm) was imaged. The lateral and the depth resolutions of the imaging system were 0.5 μm and 1 nm, respectively. The detection accuracy, which was limited by the reflectivity variation of the test surface, is discussed

  4. Molecular excited states from the SCAN functional

    Science.gov (United States)

    Tozer, David J.; Peach, Michael J. G.

    2018-06-01

    The performance of the strongly constrained and appropriately normed (SCAN) meta-generalised gradient approximation exchange-correlation functional is investigated for the calculation of time-dependent density-functional theory molecular excitation energies of local, charge-transfer and Rydberg character, together with the excited ? potential energy curve in H2. The SCAN results frequently resemble those obtained using a global hybrid functional, with either a standard or increased fraction of exact orbital exchange. For local excitations, SCAN can exhibit significant triplet instability problems, resulting in imaginary triplet excitation energies for a number of cases. The Tamm-Dancoff approximation offers a simple approach to improve the situation, but the excitation energies are still significantly underestimated. Understanding the origin of these (near)-triplet instabilities may provide useful insight into future functional development.

  5. Human performance in radiological survey scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.

  6. MutScan: fast detection and visualization of target mutations by scanning FASTQ data.

    Science.gov (United States)

    Chen, Shifu; Huang, Tanxiao; Wen, Tiexiang; Li, Hong; Xu, Mingyan; Gu, Jia

    2018-01-22

    Some types of clinical genetic tests, such as cancer testing using circulating tumor DNA (ctDNA), require sensitive detection of known target mutations. However, conventional next-generation sequencing (NGS) data analysis pipelines typically involve different steps of filtering, which may cause miss-detection of key mutations with low frequencies. Variant validation is also indicated for key mutations detected by bioinformatics pipelines. Typically, this process can be executed using alignment visualization tools such as IGV or GenomeBrowse. However, these tools are too heavy and therefore unsuitable for validating mutations in ultra-deep sequencing data. We developed MutScan to address problems of sensitive detection and efficient validation for target mutations. MutScan involves highly optimized string-searching algorithms, which can scan input FASTQ files to grab all reads that support target mutations. The collected supporting reads for each target mutation will be piled up and visualized using web technologies such as HTML and JavaScript. Algorithms such as rolling hash and bloom filter are applied to accelerate scanning and make MutScan applicable to detect or visualize target mutations in a very fast way. MutScan is a tool for the detection and visualization of target mutations by only scanning FASTQ raw data directly. Compared to conventional pipelines, this offers a very high performance, executing about 20 times faster, and offering maximal sensitivity since it can grab mutations with even one single supporting read. MutScan visualizes detected mutations by generating interactive pile-ups using web technologies. These can serve to validate target mutations, thus avoiding false positives. Furthermore, MutScan can visualize all mutation records in a VCF file to HTML pages for cloud-friendly VCF validation. MutScan is an open source tool available at GitHub: https://github.com/OpenGene/MutScan.

  7. EXAFS analysis of cations distribution in structure of Co{sub 1−x}Ni{sub x}Fe{sub 2}O{sub 4} nanoparticles obtained by hydrothermal method in aloe vera extract solution

    Energy Technology Data Exchange (ETDEWEB)

    Wongpratat, Unchista [Materials Science and Nanotechnology Program, Faculty of Science, Khon Kaen University, Khon Kaen 40002 (Thailand); Maensiri, Santi [School of Physics, Institute of Science, Suranaree University, Nakhonratchasima 30000 (Thailand); Swatsitang, Ekaphan, E-mail: ekaphan@kku.ac.th [Materials Science and Nanotechnology Program, Faculty of Science, Khon Kaen University, Khon Kaen 40002 (Thailand); Integrated Nanotechnology Research Center, Department of Physics, Faculty of Science, Khon Kaen University, Khon Kaen 40002 Thailand (Thailand)

    2016-09-01

    Graphical abstract: It is obvious from the M–H curves at room temperature of Co{sub 1−x}Ni{sub x}Fe{sub 2}O{sub 4} (x = 0, 0.25, 0.50, 0.75 and 1.0) nanoparticles that partially substitution of the lower Bohr magneton (2 μ{sub B}) and smaller atomic radii (0.55 Å at A site, 0.69 Å at B site) of Ni{sup 2+} ions on the higher Bohr magneton (3 μ{sub B}) and larger atomic radii (0.58 Å at A site, 0.74 Å at B site) of Co{sup 2+} ions can increase the saturation magnetization (M{sub s}) of sample with x = 0.75 to approximately 1.4 times of sample with x = 0, due to the increase of the aspect ratio (surface to volume) of nanoparticles, as a result of particle size decreasing from 37.03 to 12.63 nm. In addition to this, the ferrimagnetic behavior of CoFe{sub 2}O{sub 4} has been changed to superparamagnetic behavior with the dramatic decrease of the coercivity from 1365.60 to 63.15 Oe. - Highlights: • Magnetic behavior of Co{sub 1−x}Ni{sub x}Fe{sub 2}O{sub 4} NPs depends on Ni content and size of NPs. • Distribution of Co{sup 2+} and Ni{sup 2+} ions in the structure results in the increase of M{sub s}. • Superparamagnetic behavior is observed with increasing of the aspect ratio. • M{sub s} is increased by a factor 1.4 to a value of 57.57 emu/g in Co{sub 0.25}Ni{sub 0.75}Fe{sub 2}O{sub 4}. • H{sub c} is decreased by a factor 20 to a value of 63.15 Oe in Co{sub 0.25}Ni{sub 0.75}Fe{sub 2}O{sub 4}. - Abstract: Effect of cations distribution upon EXAFS analysis on magnetic properties of Co{sub 1−x}Ni{sub x}Fe{sub 2}O{sub 4} (x = 0, 0.25, 0.50, 0.75 and 1.0) nanoparticles prepared by the hydrothermal method in aloe vera extract solution were studied. XRD analysis confirmed a pure phase of cubic spinel ferrite of all samples. Changes in lattice parameter and particle size depended on the Ni content with partial substitution and site distributions of Co{sup 2+}, Ni{sup 2+} ions of different ionic radii at both tetrahedral and octahedral sites in the

  8. EXAFS analysis of cations distribution in structure of Co_1_−_xNi_xFe_2O_4 nanoparticles obtained by hydrothermal method in aloe vera extract solution

    International Nuclear Information System (INIS)

    Wongpratat, Unchista; Maensiri, Santi; Swatsitang, Ekaphan

    2016-01-01

    Graphical abstract: It is obvious from the M–H curves at room temperature of Co_1_−_xNi_xFe_2O_4 (x = 0, 0.25, 0.50, 0.75 and 1.0) nanoparticles that partially substitution of the lower Bohr magneton (2 μ_B) and smaller atomic radii (0.55 Å at A site, 0.69 Å at B site) of Ni"2"+ ions on the higher Bohr magneton (3 μ_B) and larger atomic radii (0.58 Å at A site, 0.74 Å at B site) of Co"2"+ ions can increase the saturation magnetization (M_s) of sample with x = 0.75 to approximately 1.4 times of sample with x = 0, due to the increase of the aspect ratio (surface to volume) of nanoparticles, as a result of particle size decreasing from 37.03 to 12.63 nm. In addition to this, the ferrimagnetic behavior of CoFe_2O_4 has been changed to superparamagnetic behavior with the dramatic decrease of the coercivity from 1365.60 to 63.15 Oe. - Highlights: • Magnetic behavior of Co_1_−_xNi_xFe_2O_4 NPs depends on Ni content and size of NPs. • Distribution of Co"2"+ and Ni"2"+ ions in the structure results in the increase of M_s. • Superparamagnetic behavior is observed with increasing of the aspect ratio. • M_s is increased by a factor 1.4 to a value of 57.57 emu/g in Co_0_._2_5Ni_0_._7_5Fe_2O_4. • H_c is decreased by a factor 20 to a value of 63.15 Oe in Co_0_._2_5Ni_0_._7_5Fe_2O_4. - Abstract: Effect of cations distribution upon EXAFS analysis on magnetic properties of Co_1_−_xNi_xFe_2O_4 (x = 0, 0.25, 0.50, 0.75 and 1.0) nanoparticles prepared by the hydrothermal method in aloe vera extract solution were studied. XRD analysis confirmed a pure phase of cubic spinel ferrite of all samples. Changes in lattice parameter and particle size depended on the Ni content with partial substitution and site distributions of Co"2"+, Ni"2"+ ions of different ionic radii at both tetrahedral and octahedral sites in the crystal structure. Particle sizes of samples estimated by TEM images were found to be in the range of 10.87–62.50 nm. The VSM results at room

  9. Incidental apical disease at CT scanning

    International Nuclear Information System (INIS)

    McLoud, T.C.; Satoh, K.; Shepard, J.O.; Moore, E.H.; Kosiuk, J.P.

    1990-01-01

    Apical caps are commonly noted on standard radiographs. This paper determines how often abnormalities in the extreme apex of the lung could be identified on CT scans obtained for other reasons. A total of 158 consecutive CT scans were reviewed prospectively. Excluded were patients with obvious upper lobe pleural or parenchymal disease. Apical abnormalities were identified in 74 (46.8%) of the 158 cases. The prevalence increased with age (19% in the 8-39-year age group and 82% in patients older than 80 years). Opacities were unilateral in 44.5% and bilateral in 55.5%. The most common abnormality was linear opacities (95%)

  10. Indigenous development of scanning electron microscope

    International Nuclear Information System (INIS)

    Ambastha, K.P.; Chaudhari, Y.V.; Pal, Suvadip; Tikaria, Amit; Pious, Lizy; Dubey, B.P.; Chadda, V.K.

    2009-01-01

    Scanning electron microscope (SEM) is a precision instrument and plays very important role in scientific studies. Bhabha Atomic Research Centre has taken up the job of development of SEM indigenously. Standard and commercially available components like computer, high voltage power supply, detectors etc. shall be procured from market. Focusing and scanning coils, vacuum chamber, specimen stage, control hardware and software etc. shall be developed at BARC with the help of Indian industry. Procurement, design and fabrication of various parts of SEM are in progress. (author)

  11. Scanning laser ophthalmoscope design with adaptive optics

    OpenAIRE

    Laut, SP; Jones, SM; Olivier, SS; Werner, JS

    2005-01-01

    A design for a high-resolution scanning instrument is presented for in vivo imaging of the human eye at the cellular scale. This system combines adaptive optics technology with a scanning laser ophthalmoscope (SLO) to image structures with high lateral (∼2 μm) resolution. In this system, the ocular wavefront aberrations that reduce the resolution of conventional SLOs are detected by a Hartmann-Shack wavefront sensor, and compensated with two deformable mirrors in a closed-loop for dynamic cor...

  12. Developments in Scanning Hall Probe Microscopy

    Science.gov (United States)

    Chouinard, Taras; Chu, Ricky; David, Nigel; Broun, David

    2009-05-01

    Low temperature scanning Hall probe microscopy is a sensitive means of imaging magnetic structures with high spatial resolution and magnetic flux sensitivity approaching that of a Superconducting Quantum Interference Device. We have developed a scanning Hall probe microscope with novel features, including highly reliable coarse positioning, in situ optimization of sensor-sample alignment and capacitive transducers for linear, long range positioning measurement. This has been motivated by the need to reposition accurately above fabricated nanostructures such as small superconducting rings. Details of the design and performance will be presented as well as recent progress towards time-resolved measurements with sub nanosecond resolution.

  13. Bone scan features in spontaneous knee pain.

    Science.gov (United States)

    Vattimo, A; Merlo, F; Bertelli, P; Burroni, L

    1992-01-01

    In 21 patients with "spontaneous" knee pain, 99mTc-MDP bone scan was found to be more sensitive than clinical and radiographic examination in detecting alterations of the joint components. These alterations were shown by increased radionuclide uptake in the compartments where pain was present, which was most commonly the medial femorotibial compartment, although the femoropatellar compartment was also frequently affected. The authors conclude that bone scan should be the first imaging study performed on the knee in order to establish if further tests are necessary.

  14. What expects orthopedic surgeon from bone scan?

    International Nuclear Information System (INIS)

    Sutter, B.; Cazenave, A.

    2003-01-01

    The isotope bone scan continues to be one of the 'lost widely performed nuclear medicine investigations. Beyond the common clinical indication like detection of skeletal metastases, bone scan use is increasing in benign orthopedic conditions, and after orthopedic surgery, despite development of new investigations modalities (US, MRI). Three (or two) phase bone scintigraphy, Single Photon Emission Computer Tomography have increased its value and provided new clinical roles. This review emphasizes through some practical clinical examples how to increase diagnostic value of the method and to offer an adapted response to the orthopedic surgeon's attempts. (author)

  15. Radiochemicals used to scan the heart

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Techniques for heart scanning using 201 Tl and /sup 99m/Tc pyrophosphate are discussed. Thallium-201, produced artificially in a cyclotron, concentrates in normal heart muscle but not in abnormal tissue. Technetium-99m is deposited in mitochondria of heart cells that are irreversibly damaged. The combined use of 201 Tl and /sup 99m/Tc makes it possible to identify regions of recent heart damage as well as older heart damage. Advantages of using 129 Cs for heart scanning are also discussed

  16. Gallium-67 citrate scan in extrapulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lin Wanyu [Taichung Veterans General Hospital (Taiwan). Dept. of Nuclear Medicine; Hsieh Jihfang [Chi-Mei Foundation Hospital, Tainan (Taiwan)

    1999-07-01

    Aim: Whole-body gallium scan was performed to evaluate the usefulness of gallium scan for detecting extrapulmonary tuberculosis (TB) lesions. Methods: Thirty-seven patients with extrapulmonary TB were included in this study. Four patients were found to have two lesions. Totally, 41 lesions were identified, including 19 TB arthritis, 8 spinal TB, 5 TB meningitis, 3 TB lymphadenopathy, 2 TB pericarditis, 1 TB peritonitis, 1 intestinal TB, 1 skin TB and 1 renal TB. Results: Of the 41 extrapulmonary TB lesions, gallium scan detected 32 lesions with a sensitivity of 78%. All the patients with TB meningitis showed negative gallium scan. When the five cases of TB meningitis were excluded, the detection sensitivity of gallium scan increased to 88.9% (32/36). Conclusion: Our data revealed that gallium scan is a convenient and useful method for evaluating extrapulmonary TB lesions other than TB-meningitis. We suggest that gallium scan be included in the clinical routine for patients with suspected extrapulmonary TB. (orig.) [German] Ziel: Es wurden Ganzkoerper-Gallium-Szintigramme angefertigt, um den Nutzen der Gallium-Szintigraphie zur Erfassung von extrapulmonalen Tuberkuloseherden (TB) zu erfassen. Methoden: 37 Patienten mit extrapulmonaler TB wurden eingeschlossen. 4 Patienten hatten 2 Laesionen. Insgesamt wurden 41 Laesionen identifiziert, hierunter 19 TB-Arthritis, 8 spinale TB, 5 TB-Meningitis, 3 TB-Lymphadenopathie, 2 TB-Perikarditis, 1 TB-Peritonitis, 1 intestinale TB, 1 Haut-TB und eine Nieren-TB. Ergebnisse: Von den 41 extrapulmonalen TB-Herden erfasste die Gallium-Szintigraphie 32 Herde mit einer Sensitivitaet von 78%. Alle Patienten mit TB-Meningitis zeigten einen negativen Gallium-Scan. Wenn die 5 Faelle mit TB-Meningitis ausgeschlossen wurden, stieg die Sensitivititaet der Gallium-Szintigraphie auf 88,9% (32/36). Schlussfolgerung: Die Daten zeigen, dass die Gallium-Szintigraphie eine einfache und nuetzliche Methode zur Erfassung extrapulmonaler TB-Herde ist

  17. Thyroiditis: Radioisotope Scan Findings and Clinical Significance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Chae; Han, Duck Sup; Park, Jung Suck; Kim, Se Jong; Park, Byung Lan; Kim, Byoung Geun [Kwangju Christian Hospital, Kwangju (Korea, Republic of)

    1991-07-15

    We analyzed Radioisotope scan findings of 46 patients of thyroiditis which were proven pathologically at K.C.H. The results were as follows 1) 45 patients were female, one was male and average age of patients was 37 years old. 2) The lesion site was predominant in both lobe (67%) Hashimoto's thyroiditis showed enlarged thyroid (85%) with cold nodule (20%), diffuse decreased activity (10%), while subacute thyroiditis was presented absent activity (53%), poor visualization (20%) or cold nodule (7%). 4) Radioisotope scan was valuable in evaluating function of thyroid gland and detection of lesion but there was a limit of pathological nature.

  18. Bone scanning in Shin Splint evaluation

    International Nuclear Information System (INIS)

    Dumont, M.; Lamoureux, F.; Lamoureux, J.; Danais, S.; Lacoste, P.; Duranceau, J.

    1983-01-01

    Jogging is increasingly popular; in U.S.A., in 1979 more than 25 millions people were considered joggers. Lesions of the locomotive system of the lower limbs are very frequent in athletes and the Shin Splint syndrome, for one, is very frequent. However this precise clinical entity, usually X-Ray negative, is ill-known. A bone scan study in a series of 30 athletes suffering from Shin Splints is presented. The bone scans being positive and typical were highly useful in confirming the clinical diagnosis. Moreover, follow-up studies were done in a number of these patients and results correlated well with the clinical evolution [fr

  19. Dexter: Data Extractor for scanned graphs

    Science.gov (United States)

    Demleitner, Markus

    2011-12-01

    The NASA Astrophysics Data System (ADS) now holds 1.3 million scanned pages, containing numerous plots and figures for which the original data sets are lost or inaccessible. The availability of scans of the figures can significantly ease the regeneration of the data sets. For this purpose, the ADS has developed Dexter, a Java applet that supports the user in this process. Dexter's basic functionality is to let the user manually digitize a plot by marking points and defining the coordinate transformation from the logical to the physical coordinate system. Advanced features include automatic identification of axes, tracing lines and finding points matching a template.

  20. Role of bone scanning in osteomalacia

    International Nuclear Information System (INIS)

    Fogelman, I.; McKillop, J.H.; Bessent, R.G.; Boyle, I.T.; Turner, J.G.; Greig, W.R.

    1978-01-01

    The presence of eight ''metabolic features'' was assessed on the bone scintigrams of ten patients with osteomalacia. In all of these bone images, sufficient features were present to strongly suggest a metabolic disorder. These scintiphotos were included in a controlled blind study using 30 normal bone scans and 20 scans of metastatic disease. Nine of the ten metabolic bone images were correctly identified by two independent observers. Skeletal uptake of radiotracer, expressed as bone-to-soft-tissue ratio, was significantly higher in the osteomalacic patients than in a group of 80 controls

  1. Scan posture definition and hip girth measurement: the impact on clothing design and body scanning.

    Science.gov (United States)

    Gill, Simeon; Parker, Christopher J

    2017-08-01

    Ergonomic measurement is central to product design and development; especially for body worn products and clothing. However, there is a large variation in measurement definitions, complicated by new body scanning technology that captures measurements in a posture different to traditional manual methods. Investigations of hip measurement definitions in current clothing measurement practices supports analysis of the effect of scan posture and hip measurement definition on the circumferences of the hip. Here, the hip girth is a key clothing measurement that is not defined in current body scanning measurement standards. Sixty-four participants were scanned in the standard scan posture of a [TC] 2 body scanner, and also in a natural posture similar to that of traditional manual measurement collection. Results indicate that scan posture affects hip girth circumferences, and that some current clothing measurement practices may not define the largest lower body circumference. Recommendations are made concerning how the hip is defined in measurement practice and within body scanning for clothing product development. Practitioner Summary: The hip girth is an important measurement in garment design, yet its measurement protocol is not currently defined. We demonstrate that body posture during body scanning affects hip circumferences, and that current clothing measurement practices may not define the largest lower body circumference. This paper also provides future measurement practice recommendations.

  2. The Scanning Theremin Microscope: A Model Scanning Probe Instrument for Hands-On Activities

    Science.gov (United States)

    Quardokus, Rebecca C.; Wasio, Natalie A.; Kandel, S. Alex

    2014-01-01

    A model scanning probe microscope, designed using similar principles of operation to research instruments, is described. Proximity sensing is done using a capacitance probe, and a mechanical linkage is used to scan this probe across surfaces. The signal is transduced as an audio tone using a heterodyne detection circuit analogous to that used in…

  3. DepositScan, a Scanning Program to Measure Spray Deposition Distributions

    Science.gov (United States)

    DepositScan, a scanning program was developed to quickly measure spray deposit distributions on water sensitive papers or Kromekote cards which are widely used for determinations of pesticide spray deposition quality on target areas. The program is installed in a portable computer and works with a ...

  4. Scanning reference electrode techniques in localized corrosion

    International Nuclear Information System (INIS)

    Isaacs, H.S.; Vyas, B.

    1979-04-01

    The principles, advantages, and implementations of scanning reference electrode techniques are reviewed. Data related to pitting, intergranular corrosion, welds and stress corrosion cracking are presented. The technique locates the position of localized corrosion and can be used to monitor the development of corrosion and changes in the corrosion rate under a wide range of conditions

  5. Exabyte helical scan devices at Fermilab

    International Nuclear Information System (INIS)

    Constanta-Fanourakis, P.; Kaczar, K.; Oleynik, G.; Petravick, D.; Votava, M.; White, V.; Hockney, G.; Bracker, S.; de Miranda, J.M.

    1989-05-01

    Exabyte 8mm helical scan storage devices are in use at Fermilab in a number of applications. These devices have the functionality of magnetic tape, but use media which is much more economical and much more dense than conventional 9 track tape. 6 refs., 3 figs

  6. High resolution RGB color line scan camera

    Science.gov (United States)

    Lynch, Theodore E.; Huettig, Fred

    1998-04-01

    A color line scan camera family which is available with either 6000, 8000 or 10000 pixels/color channel, utilizes off-the-shelf lenses, interfaces with currently available frame grabbers, includes on-board pixel by pixel offset correction, and is configurable and controllable via RS232 serial port for computer controlled or stand alone operation is described in this paper. This line scan camera is based on an available 8000 element monochrome line scan camera designed by AOA for OEM use. The new color version includes improvements such as better packaging and additional user features which make the camera easier to use. The heart of the camera is a tri-linear CCD sensor with on-chip color balancing for maximum accuracy and pinned photodiodes for low lag response. Each color channel is digitized to 12 bits and all three channels are multiplexed together so that the resulting camera output video is either a 12 or 8 bit data stream at a rate of up to 24Megpixels/sec. Conversion from 12 to 8 bit, or user-defined gamma, is accomplished by on board user-defined video look up tables. The camera has two user-selectable operating modes; lows speed, high sensitivity mode or high speed, reduced sensitivity mode. The intended uses of the camera include industrial inspection, digital archiving, document scanning, and graphic arts applications.

  7. Electrochemical gating in scanning electrochemical microscopy

    NARCIS (Netherlands)

    Ahonen, P.; Ruiz, V.; Kontturi, K.; Liljeroth, P.; Quinn, B.M.

    2008-01-01

    We demonstrate that scanning electrochemical microscopy (SECM) can be used to determine the conductivity of nanoparticle assemblies as a function of assembly potential. In contrast to conventional electron transport measurements, this method is unique in that electrical connection to the film is not

  8. Role of bone scanning in neonatal rickets

    Energy Technology Data Exchange (ETDEWEB)

    Saul, P.D.; Lloyd, D.J.; Smith, F.W.

    1983-03-01

    Preterm infants are at increased risk from rickets. Radionuclide bone scanning is a useful aid in suspected cases. It offers advantages over conventional radiology in terms of sensitivity, radiation dose and extent of examination. Unsuspected fractures of clinical or medicolegal significance may be detected. Two cases are described in which the technique confirmed the diagnosis and assisted management.

  9. Fast rendering of scanned room geometries

    DEFF Research Database (Denmark)

    Olesen, Søren Krarup; Markovic, Milos; Hammershøi, Dorte

    2014-01-01

    Room acoustics are rendered in Virtual Realities based on models of the real world. These are typically rather coarse representations of the true geometry resulting in room impulse responses with a lack of natural detail. This problem can be overcome by using data scanned by sensors, such as e...

  10. Algorithms for coding scanned halftone pictures

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Forchhammer, Morten

    1988-01-01

    A method for coding scanned documents containing halftone pictures, e.g. newspapers and magazines, for transmission purposes is proposed. The halftone screen is estimated and the grey value of each dot is found, thus giving a compact description. At the receiver the picture is rescreened. A novel...

  11. Plague and the gallium scan: case report

    International Nuclear Information System (INIS)

    Stahly, T.L.; Shoop, J.D.

    1975-01-01

    Inflammation in the right axillary lymph nodes and the meninges was detected by 67 Ga-citrate scans in an 11-year-old boy with Yersinia pestis infection. This case provides another example of 67 Ga localizing to areas of infection, indicating potential utility in future cases of bubonic plague

  12. Study of Scanning Tunneling Microscope control electronics

    International Nuclear Information System (INIS)

    Oliva, A.J.; Pancarobo, M.; Denisenko, N.; Aguilar, M.; Rejon, V.; Pena, J.L.

    1994-01-01

    A theoretical study of Scanning Tunneling Microscope control electronics is made. The knowledge of its behaviour allows us to determine accurately the region where the unstable operation could effect the measurements, and also to set the optimal working parameters. Each feedback circuitry compound is discussed as well as their mutual interaction. Different working conditions analysis and results are presented. (Author) 12 refs

  13. Investigation into scanning tunnelling luminescence microscopy

    International Nuclear Information System (INIS)

    Manson-Smith, S.K.

    2001-01-01

    This work reports on the development of a scanning tunnelling luminescence (STL) microscope and its application to the study of Ill-nitride semiconductor materials used in the production of light emitting devices. STL microscopy is a technique which uses the high resolution topographic imaging capabilities of the scanning tunnelling microscope (STM) to generate high resolution luminescence images. The STM tunnelling current acts as a highly localised source of electrons (or holes) which generates luminescence in certain materials. Light generated at the STM tunnelling junction is collected concurrently with the height variation of the tunnelling probe as it is scanned across a sample surface, producing simultaneous topographic and luminescence images. Due to the very localised excitation source, high resolution luminescence images can be obtained. Spectroscopic resolution can be obtained by using filters. Additionally, the variation of luminescence intensity with tunnel current and with bias voltage can provide information on recombination processes and material properties. The design and construction of a scanning tunnelling luminescence microscope is described in detail. Operating under ambient conditions, the microscope has several novel features, including a new type of miniature inertial slider-based approach motor, large solid-angle light collection optical arrangement and a tip-height regulation system which requires the minimum of operator input. (author)

  14. Eye scanning activity influenced by temperament traits

    Czech Academy of Sciences Publication Activity Database

    Lukavský, Jiří

    2005-01-01

    Roč. 34, - (2005), s. 121 ISSN 0301-0066. [European Conference on Visual Perception 2005. 22.08.2005-26.08.2005] Institutional research plan: CEZ:AV0Z70250504 Keywords : Eye movements * scanning * temperament * TCI-R * Rorschach test Subject RIV: AN - Psychology

  15. High-pressure differential scanning microcalorimeter.

    Science.gov (United States)

    Senin, A A; Dzhavadov, L N; Potekhin, S A

    2016-03-01

    A differential scanning microcalorimeter for studying thermotropic conformational transitions of biopolymers at high pressure has been designed. The calorimeter allows taking measurements of partial heat capacity of biopolymer solutions vs. temperature at pressures up to 3000 atm. The principles of operation of the device, methods of its calibration, as well as possible applications are discussed.

  16. Multiplatform Mobile Laser Scanning: Usability and Performance

    Directory of Open Access Journals (Sweden)

    Yuwei Chen

    2012-08-01

    Full Text Available Mobile laser scanning is an emerging technology capable of capturing three-dimensional data from surrounding objects. With state-of-the-art sensors, the achieved point clouds capture object details with good accuracy and precision. Many of the applications involve civil engineering in urban areas, as well as traffic and other urban planning, all of which serve to make 3D city modeling probably the fastest growing market segment in this field. This article outlines multiplatform mobile laser scanning solutions such as vehicle- and trolley-operated urban area data acquisition, and boat-mounted equipment for fluvial environments. Moreover, we introduce a novel backpack version of mobile laser scanning equipment for surveying applications in the field of natural sciences where the requirements include precision and mobility in variable terrain conditions. In addition to presenting a technical description of the systems, we discuss the performance of the solutions in the light of various applications in the fields of urban mapping and modeling, fluvial geomorphology, snow-cover characterization, precision agriculture, and in monitoring the effects of climate change on permafrost landforms. The data performance of the mobile laser scanning approach is described by the results of an evaluation of the ROAMER on a permanent MLS test field. Furthermore, an in situ accuracy assessment using a field of spherical 3D targets for the newly-introduced Akhka backpack system is conducted and reported on.

  17. Laser scanning camera inspects hazardous area

    International Nuclear Information System (INIS)

    Fryatt, A.; Miprode, C.

    1985-01-01

    Main operational characteristics of a new laser scanning camera are presented. The camera is intended primarily for low level high resolution viewing inside nuclear reactors. It uses a He-Ne laser beam raster; by detecting the reflected light by means of a phomultiplier, the subject under observation can be reconstructed in an electronic video store and reviewed on a conventional monitor screen

  18. Efficient scanning of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Meenakshisundaram, V.

    1978-01-01

    Lead containers fabricated for transport of radioactive materials need to be evaluated for their shielding integrity. The common method of locating a strong gamma source inside the vessel and scanning the external surface by conventional detectors suffers from high radiation dose and low sensitivity. A new method has been proposed and tried. It is found to be more efficient. In the new method, 60 Co source is loaded at the centre of the lead vessel and the outer surface is scanned by NaI(Tl) detector. The transmitted virgin flux is scanned under the 60 Co channel in a single channel analyser. An area of 25 cm 2 is scanned for 10 to 20 seconds each time. The source strength required is considerably reduced by a factor of 10 or more as compared to the common method and external dose rates do not exceed 50 mR/h (130 nC. kg -1 h -1 ) on the vessel surface. The advantages are improved sensitivity, no interference from scattered radiation and assurance in repeatability of measurements. (M.G.B.)

  19. Atypical Saccadic Scanning in Autistic Spectrum Disorder

    Science.gov (United States)

    Benson, Valerie; Piper, Jenna; Fletcher-Watson, Sue

    2009-01-01

    Saccadic scanning was examined for typically developing (TD) adults and those with autistic spectrum disorder (ASD) during inspection of the "Repin" picture (Yarbus, A. (1967). "Eye movements and vision". New York: Plenum) under two different viewing instructions: (A) material instructions ("Estimate the material circumstances of the family"); and…

  20. Interval scanning photomicrography of microbial cell populations.

    Science.gov (United States)

    Casida, L. E., Jr.

    1972-01-01

    A single reproducible area of the preparation in a fixed focal plane is photographically scanned at intervals during incubation. The procedure can be used for evaluating the aerobic or anaerobic growth of many microbial cells simultaneously within a population. In addition, the microscope is not restricted to the viewing of any one microculture preparation, since the slide cultures are incubated separately from the microscope.