WorldWideScience

Sample records for sc glucose measurements

  1. Magnet measuring equipment of SC2

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    Checking the positioning of the magnet measuring equipment installed between the poles of SC2. The steel structure in front of the magnet is designed to house the rotary condenser and to shield it from the stray magnetic field of the accelerator.

  2. Magnet measuring equipment of SC2

    CERN Multimedia

    1974-01-01

    Checking the positioning of the magnet measuring equipment installed between the poles of SC2. The steel structure in front of the magnet is designed to house the rotary condenser and to shield it from the stray magnetic field of the accelerator. On the left, Marinus van Gulik. (See Photo Archive 7402005 and Annual Report 1974, p. 44.)

  3. Methods for production of UNK SC-dipoles magnetic measurements

    International Nuclear Information System (INIS)

    Smirnov, N.L.

    1991-01-01

    Many SC-dipoles for UNK will require from the chosen magnetic measurement methods high accuracy and efficiency. The brief of using methods, their possibilities and analysis of their errors are given. The measurements results for a full-scale model of SC-dipole SPDM1 are presented. 5 refs.; 4 figs.; 4 tabs

  4. Measuring brain glucose phosphorylation with labeled glucose

    International Nuclear Information System (INIS)

    Brondsted, H.E.; Gjedde, A.

    1988-01-01

    This study tested whether glucose labeled at the C-6 position generates metabolites that leave brain so rapidly that C-6-labeled glucose cannot be used to measure brain glucose phosphorylation (CMRGlc). In pentobarbital-anesthetized rats, the parietal cortex uptake of [ 14 C]glucose labeled in the C-6 position was followed for times ranging from 10 s to 60 min. We subtracted the observed radioactivity from the radioactivity expected with no loss of labeled metabolites from brain by extrapolation of glucose uptake in an initial period when loss was negligible. The observed radioactivity was a monoexponentially declining function of the total radioactivity expected in the absence of metabolite loss. The constant of decline was 0.0077.min-1 for parietal cortex. Metabolites were lost from the beginning of the experiment. However, with correction for the loss of labeled metabolites, it was possible to determine an average CMRGlc between 4 and 60 min of circulation of 64 +/- 4 (SE; n = 49) mumol.hg-1.min-1

  5. Energy Levels, wavelengths and hyperfine structure measurements of Sc II

    Science.gov (United States)

    Hala, Fnu; Nave, Gillian

    2018-01-01

    Lines of singly ionized Scandium (Sc II) along with other Iron group elements have been observed [1] in the region surrounding the massive star Eta Carinae [2,3] called the strontium filament (SrF). The last extensive analysis of Sc II was the four-decade old work of Johansson & Litzen [4], using low-resolution grating spectroscopy. To update and extend the Sc II spectra, we have made observation of Sc/Ar, Sc/Ne and Sc/Ge/Ar hollow cathode emission spectrum on the NIST high resolution FT700 UV/Vis and 2 m UV/Vis/IR Fourier transform spectrometers (FTS). More than 850 Sc II lines have been measured in the wavelength range of 187 nm to 3.2 μm. connecting a total of 152 energy levels. The present work also focuses to resolve hyperfine structure (HFS) in Sc II lines. We aim to obtain accurate transition wavelengths, improved energy levels and HFS constants of Sc II. The latest results from work in progress will be presented.Reference[1] Hartman H, Gull T, Johansson S and Smith N 2004 Astron. Astrophys. 419 215[2] Smith N, Morse J A and Gull T R 2004 Astrophys. J. 605 405[3] Davidson K and Humphreys R M 1997 Annu. Rev. Astron. Astrophys. 35[4] Johansson S and Litzén U 1980 Phys. Scr. 22 49

  6. Measurement for commercial exposives with SC-DSC test. Sangyoyo bakuhayaku no SC-DSC sokutei

    Energy Technology Data Exchange (ETDEWEB)

    Yabashi, H.; Wada, Y.; Hwang, D.; Akutsu, Y.; Tamura, M.; Yoshida, T. (The University of Tokyo, Tokyo (Japan). Faculty of Engineering); Matsuzawa, T. (Nippon Kayaku Co. Ltd., Tokyo (Japan))

    1991-08-30

    The sealed cell differential scanning calorimetry (SC-DSC) was sintroduced of commercial blasting explosives. As a series of testing the commercial blasting explosives in performance, an SC-DSC test was made to compare the critical detonability line with that resulting therefrom. From the result of SC-DSC measurement, the critical dilution rate was estimated of commercial blasting explosives to become without detonating propagation. As a result, all the explosives with exception of ANFO one were assumed to have a possibility of detonating propagation so that the ANFO explosive was known to be material, unable to exactly evaluate the detonability by the SC-DSC test. The explosion heat, then calculated by the REITP2 in order to assume how the reaction proceeded in the DSC cell, was compared with the reaction heat measured by the SC-DSC test. As a result, the calculated value was known to be almost equal to or slightly larger than the measured one. 15 refs., 4 figs., 2 tabs.

  7. Lifetime and g-factor measurements in 44Sc

    International Nuclear Information System (INIS)

    Chevallier, A.; Chavallier, J.; Gross, J.L.; Haas, B.; Schulz, N.; Styczen, J.; Toulemonde, M.

    1975-01-01

    The lifetimes of the 235 keV, 2 - state and 350 keV, 4 + state in 44 Sc have been measured via the 44 Ca(p, n) 44 Sc reaction with a pulsed proton beam. The time integral perturbed angular distribution technique with an external field was used to measure the precession angles of the 2 - and 4 + states populated by the 30 Si( 16 O, pnγ) 44 Sc reaction. The following values for the mean-lives and g-factors were obtained: π(2 - ) = 8.83(33) ns, g(2 - ) = 0.30(13) and π(4 + ) = 4.52(27)ns, g(4 + ) = 0.90(12). The results for the 2 - state support a rotational description of the negative parity states in 44 Sc. The magnetic moment of the 4 + state is compared to shell model predictions. (orig.) [de

  8. A review of metabolism of labeled glucoses for use in measuring glucose recycling

    International Nuclear Information System (INIS)

    Russell, R.W.; Young, J.W.

    1990-01-01

    The fate of tritium from each carbon of D-glucose and the metabolism of L-glucose and 2-deoxy-D-glucose are known. Differences in metabolism of labeled glucoses can be used to quantify physical and chemical recycling of glucose. Only physical recycling is measured by [1- 3 H]-L-glucose, whereas [U- 14 C]-D-glucose measures total recycling. The difference between [1- 3 H]-L-glucose and [U- 14 C]-D-glucose, therefore, is chemical recycling. Recycling from extracellular binding sites and hepatic glucose 6-phosphate can be measured by difference between [1,2- 3 H]-2-deoxy-D-glucose and [1- 3 H]-L-glucose, and the difference in irreversible loss of the two will measure extrahepatic uptake of D-glucose. Recycling via Cori-alanine cycle plus CO 2 is the difference in irreversible loss measured by using [6- 3 H]-glucose and [U- 14 C]-D-glucose. Recycling via the hexose monophosphate pathway can be determined by difference in irreversible loss between [1- 3 H]-D-glucose and [6- 3 H]-D-glucose. Recycling via CO 2 and glycerol must be measured directly with [U- 14 C]glucose, bicarbonate, and glycerol. Recycling via hepatic glycogen can be estimated by subtracting all other measured chemical recycling from total chemical recycling. This review describes means to quantify glucose recycling in vivo, enabling studies of mechanisms for conservation and utilization of glucose. 54 references

  9. On measuring the UNK SC-dipole bending strength with rotating pick-up coil

    International Nuclear Information System (INIS)

    Smirnov, N.L.; Tikhov, A.V.

    1993-01-01

    The experience in measuring the SC-dipole bending strength with the spotting method shown this measurement to be the most complicated and expensive. A convenient and simple method of rotating pick-up coil, which can not provide the required accuracy, may be used for this measurement combined with NMR measurements in the dipole central part. The physical ground and description of the method are given in the paper. The analysis of the errors and measurement results of the SPDMI SC-dipoles are presented. 9 refs..; 7 figs

  10. Measurement of the elastic tensor of SmScO3 and NdScO3 using resonant ultrasound spectroscopy with ab initio calculations

    Directory of Open Access Journals (Sweden)

    K. A. Pestka II

    2011-09-01

    Full Text Available The complete elastic tensors of SmScO3 and NdScO3 were measured using resonant ultrasound spectroscopy (RUS in combination with ab-initio calculations. Measurement of the elastic tensor of these recently synthesized single crystal RE scandates is essential for understanding dynamic lattice applications including phonon confinement, strain induced thin film growth and superlattice construction. On average, the experimental elastic constants differed by less than 5% of the theoretical values, further validating the accuracy of modern ab-initio calculations as a means of estimating the initial elastic constants used in RUS measurements.

  11. RPL-SC dosimetric system for measuring gamma and neutron irradiation in case of emergency

    International Nuclear Information System (INIS)

    Khristova, M. G.

    1993-01-01

    A RPL-SC dosimetric system is designed based on radiophotoluminescence (RPL) and on the effect of fast neutron bombardment of silicon semiconductor (SC) diodes. The experimental prototype consists of a computerized automatic measurement system and an individual dosimetric cassette accommodating RPL and SC detectors. The equipment includes: a device for measurement of the direct voltage of Si diodes and the RPL light emitted by RPL detectors; a compartment with dosimetric cassettes to be measured; a manipulator with three positions executing automatic measurement of cassettes; a computer and a printer. The system operates in both manual and automatic modes. In the manual mode each step of the manipulator is set up by the operator who changes the ranges after they have been filled to capacity and registers the results. In the automatic mode the whole process of maintaining the supply and control voltage, of manipulator's operation, measuring, data recording and data processing are controlled by a specially designed computer programme. Main technical parameters: 1) Measurement range of absorbed dose: gamma rays - 10 -3 to 10 2 Gy; thermal neutrons - 10 -3 to 10 2 Gy; fast neutrons - 10 to 30 Gy. 2) Energy range: gamma rays - 0.04 to 1.25 MeV; thermal neutrons - 0.024 eV; fast neutrons - 0.3 to 14 MeV. 3) Relative measurement error - ±15% 4) Recurrent measurement of one and the same dose. 5) Measurement time of 1 detector - 15 sec. (author)

  12. Measurement of small bowel transit time by 99Tcm-SC imaging: preliminary clinical study

    International Nuclear Information System (INIS)

    Zhang Shaohua; Xu Jingying; Bei Lian; Zhu Chaohui; Ba Jiantao

    1999-01-01

    Objective: To develop a method of measuring small bowel transit time (SBTT) by 99 Tc m -sulfur collide (SC) imaging and to compare with the method of added lactose in the test meal. Methods: 20 healthy volunteers and 26 patients with gastrointestinal disorders were studied. In fasting state, the subjects were asked to ingest the 99 Tc m -SC labelled solid meal within 5 minutes, then the image acquisition was immediately started with SPECT. The images were acquired every 15 min during the first hour, at 30 min intervals during 2∼4 hours and hourly thereafter until 80% radioactivity had entered the colon. One week later, the same procedure of imaging with 15 g lactulose added in the test meal was performed. The regions of interest (ROIs) were taken at stomach and colon, and the SBTT was calculated by deconvolution or by subtraction of the 50% time of gastric emptying from the 50% time of colon filling. Results: 1) The mean SBTT of 20 healthy volunteers was (4.2 +- 0.5) h, oral-caecum transit time (OCTT) was (4.3 +- 0.6) h; lactulose shortened the SBTT by (1.8 +- 0.6) h; 2) 26 patients showed different results of SBTT due to their different gastrointestinal disorders bases. Conclusions: 99 Tc m -SC imaging was a noninvasive and useful method to measure SBTT. The added lactulose can shorten the examination time and help to identify the time of food to the ileocecal region

  13. High precision measurements of hyperfine structure in Tm II, N2+ and Sc II

    International Nuclear Information System (INIS)

    Mansour, N.B.; Dinneen, T.P.; Young, L.

    1988-01-01

    We have applied the technique of collinear fast-ion-beam laser spectroscopy to measure the hyperfine structure (hfs) in Sc II, Tm II and N 2 + . Laser induced fluorescence was observed from a 50 keV ion beam which was superimposed with the output of an actively stabilized ring dye laser (rms bandwidth 2 and the excited 3d4p configuration of Sc II and in the 4f 13 6s and 4f 13 5d configurations of the Tm II. The fine and hyperfine structure of N 2 + has been observed in the (0,1) and (1,2) band of B 2 Σ/sub u/ + /minus/X 2 Σ/sub g/ + system. Higher resolution measurements of the metastable 3d 2 configuration in Sc II were also made by laser-rf double resonance. The experimental results will be compared with those obtained by multiconfiguration Hartree-Fock ab-initio calculations. 15 refs., 4 figs., 5 tabs

  14. Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock.

    Science.gov (United States)

    Ballesteros, D; Martínez, Ó; Blancas Gómez-Casero, R; Martín Parra, C; López Matamala, B; Estébanez, B; Chana, M

    2015-10-01

    Intermittent glycemic measurements in patients admitted to the intensive care unit (ICU) can result in episodes of severe hypoglycemia or in a poor control of glycemia range. We designed a study to assess accuracy and reliability of continuous monitoring of tissue glucose for patients with distributive shock. Consecutive patients admitted to the ICU with a diagnosis of distributive shock and the need of insulin infusion for glycemic control were included in the study. These patients were implanted a Continuous Glucose Control Monitoring System (CGMS) with the sensor inserted subcutaneously into the abdominal wall. CGMS values were recorded every 5min. Capillary glucose (CG) was monitored for adjusting insulin perfusion according to the ICU protocol. Correlation between both methods was assessed. A total of 11,673 CGMS and 348 CG values were recorded. In five patients, CGMS failed to detect tissue glucose. A glucose value <3.33mmol/l (<60mg/dl) was observed in 3.6% of CGMS and in 0.29% CG values. 295 pairs of measurements were included in the statistical analysis for correlation assessment. The intraclass correlation coefficient was 0.706. The Pearson correlation coefficient was 0.71 (p<0.0001, 95% CI 0.65-0.76). The mean of differences between both measurement methods was 0.22mmol/l (3.98mg/dl) (95% CI 0.66-7.31). When the Continuous Glucose Control Monitoring System (CGMS) is able to obtain data (75% of the patients), there is correlation between the values obtained by this method and capillary blood glucose in patients with distributive shock. CGMS can detect more episodes of glycemic excursions outside the normal range than intermittent capillary glucose monitoring. Variables that may impair glucose metabolism and peripheral soft tissues perfusion could impair CGMS measurements. Copyright © 2014 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  15. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  16. Measuring social capital through multivariate analyses for the IQ-SC.

    Science.gov (United States)

    Campos, Ana Cristina Viana; Borges, Carolina Marques; Vargas, Andréa Maria Duarte; Gomes, Viviane Elisangela; Lucas, Simone Dutra; Ferreira e Ferreira, Efigênia

    2015-01-20

    Social capital can be viewed as a societal process that works toward the common good as well as toward the good of the collective based on trust, reciprocity, and solidarity. Our study aimed to present two multivariate statistical analyses to examine the formation of latent classes of social capital using the IQ-SC and to identify the most important factors in building an indicator of individual social capital. A cross-sectional study was conducted in 2009 among working adolescents supported by a Brazilian NGO. The sample consisted of 363 individuals, and data were collected using the World Bank Questionnaire for measuring social capital. First, the participants were grouped by a segmentation analysis using the Two Step Cluster method based on the Euclidian distance and the centroid criteria as the criteria for aggregate answers. Using specific weights for each item, discriminant analysis was used to validate the cluster analysis in an attempt to maximize the variance among the groups with respect to the variance within the clusters. "Community participation" and "trust in one's neighbors" contributed significantly to the development of the model with two distinct discriminant functions (p < 0.001). The majority of cases (95.0%) and non-cases (93.1%) were correctly classified by discriminant analysis. The two multivariate analyses (segmentation analysis and canonical discriminant analysis), used together, can be considered good choices for measuring social capital. Our results indicate that it is possible to form three social capital groups (low, medium and high) using the IQ-SC.

  17. Clinical assessment of the accuracy of blood glucose measurement devices.

    Science.gov (United States)

    Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas

    2012-04-01

    Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values 400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2

  18. The relationships between common measures of glucose meter performance.

    Science.gov (United States)

    Wilmoth, Daniel R

    2012-09-01

    Glucose meter performance is commonly measured in several different ways, including the relative bias and coefficient of variation (CV), the total error, the mean absolute relative deviation (MARD), and the size of the interval around the reference value that would be necessary to contain a meter measurement at a specified probability. This fourth measure is commonly expressed as a proportion of the reference value and will be referred to as the necessary relative deviation. A deeper understanding of the relationships between these measures may aid health care providers, patients, and regulators in comparing meter performances when different measures are used. The relationships between common measures of glucose meter performance were derived mathematically. Equations are presented for calculating the total error, MARD, and necessary relative deviation using the reference value, relative bias, and CV when glucose meter measurements are normally distributed. When measurements are also unbiased, the CV, total error, MARD, and necessary relative deviation are linearly related and are therefore equivalent measures of meter performance. The relative bias and CV provide more information about meter performance than the other measures considered but may be difficult for some audiences to interpret. Reporting meter performance in multiple ways may facilitate the informed selection of blood glucose meters. © 2012 Diabetes Technology Society.

  19. A portable measuring system for a competitive binding glucose biosensor

    Science.gov (United States)

    Colvin, Lydia E.; Means, A. Kristen; Grunlan, Melissa A.; Coté, Gerard L.

    2018-02-01

    Central to minimizing the long- and short-term complications associated with diabetes is careful monitoring and maintenance of blood glucose at normal levels. Towards replacing conventionally used finger-prick glucose testing, indwelling continuous glucose monitors (CGMs) based on amperometric electrodes have been introduced to the market. Envisioned to lead to a CGM with an increased lifetime, we report herein a fluorescently-labeled competitive binding assay contained within a hydrogel membrane whose glucose response is measured via a novel portable system. The optical system design included a laser source, bifurcated fiber, laser filter and simple fiber coupled spectrometer to obtain the change in FRET pair ratio of the assay. Glucose response of the assay in free solution was measured using this system across the physiologic range (0-200 mg/dL). The FRET pair ratio signal was seen to increase with glucose and the standard error of calibration was 22.42 mg/dL with a MARD value of 14.85%. When the assay was contained within the hydrogel membrane's central cavity and similarly analyzed, the standard error increased but the assay maintained its reversibility.

  20. A Computer-Based Glucose Management System Reduces the Incidence of Forgotten Glucose Measurements: A Retrospective Observational Study.

    Science.gov (United States)

    Okura, Tsuyoshi; Teramoto, Kei; Koshitani, Rie; Fujioka, Yohei; Endo, Yusuke; Ueki, Masaru; Kato, Masahiko; Taniguchi, Shin-Ichi; Kondo, Hiroshi; Yamamoto, Kazuhiro

    2018-04-17

    Frequent glucose measurements are needed for good blood glucose control in hospitals; however, this requirement means that measurements can be forgotten. We developed a novel glucose management system using an iPod ® and electronic health records. A time schedule system for glucose measurement was developed using point-of-care testing, an iPod ® , and electronic health records. The system contains the glucose measurement schedule and an alarm sounds if a measurement is forgotten. The number of times measurements were forgotten was analyzed. Approximately 7000 glucose measurements were recorded per month. Before implementation of the system, the average number of times measurements were forgotten was 4.8 times per month. This significantly decreased to 2.6 times per month after the system started. We also analyzed the incidence of forgotten glucose measurements as a proportion of the total number of measurements for each period and found a significant difference between the two 9-month periods (43/64,049-24/65,870, P = 0.014, chi-squared test). This computer-based blood glucose monitoring system is useful for the management of glucose monitoring in hospitals. Johnson & Johnson Japan.

  1. Energy-differential cross section measurement for the 51V(n,α)48Sc reaction

    International Nuclear Information System (INIS)

    Kanno, I.; Meadows, J.W.; Smith, D.L.

    1984-07-01

    The activation method was used to measure cross sections for the 51 V(n,α) 48 Sc reaction in the threshold region, from 5.515 MeV up to 9.567 MeV. Twenty approximately-monoenergetic cross section values were obtained in this experiment. These data points span the energy region at roughly equal intervals. The experimental resolutions were in the range 0.153 to 0.233 MeV (FWHM). The present differential data cover approx. 50% of the total integral response of this reaction for the standard 235 U thermal-neutron-induced-fission neutron spectrum, and approx. 44% of the corresponding response for the standard 252 Cf spontaneous-fission neutron spectrum. Over the range 7.6 to 9.5 MeV the present experimental cross sections are noticeably larger (e.g., by approx. 50% at approx. 8.6 MeV) than the corresponding values from the ENDF/B-V evaluation. From approx. 6.7 to 7.5 MeV, the present values are somewhat below those of ENDF/B-V. At still lower energies the agreement is reasonably good considering the uncertainties introduced by energy scale definition very near the effective threshold where the cross section varies rapidly with neutron energy. Calculated integral cross sections based in part on the present work agree reasonably well within errors with reported integral results, provided that the reported data are renormalized to conform with recently-accepted values for appropriate standard reactions. 70 references

  2. Simultaneous measurement of glucose transport and utilization in the human brain

    OpenAIRE

    Shestov, Alexander A.; Emir, Uzay E.; Kumar, Anjali; Henry, Pierre-Gilles; Seaquist, Elizabeth R.; Öz, Gülin

    2011-01-01

    Glucose is the primary fuel for brain function, and determining the kinetics of cerebral glucose transport and utilization is critical for quantifying cerebral energy metabolism. The kinetic parameters of cerebral glucose transport, KMt and Vmaxt, in humans have so far been obtained by measuring steady-state brain glucose levels by proton (1H) NMR as a function of plasma glucose levels and fitting steady-state models to these data. Extraction of the kinetic parameters for cerebral glucose tra...

  3. Precise determination of 40Ti mass by measuring the 40Sc isospin analogue state

    International Nuclear Information System (INIS)

    Liu Weiping; Hellstroem, M.; Collatz, R.; Benlliure, J.; Cortina, G.D.; Farget, F.; Grawe, H.; Hu, Z.; Iwasa, N.; Pfuetzner, M.; Roeckl, E.; Chulkov, L.; Piechaczek, A.; Raabe, R.; Reusen, I.; Vancraeynest, G.; Woehr, A.

    2001-01-01

    The mass of 40 Ti has been determined by using the isobaric multiplet mass equation method. The experimental data of the 40 Ti β-decay were used to determine the level of the isospin analogue state of 40 Sc. The ground-state mass excess and the Q EC value for 40 Ti were determined to be -9060 +- 12 keV and 11466 +- 13 keV, respectively

  4. Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers

    Science.gov (United States)

    Yoshioka, Kiriko; Kino, Saiko; Matsuura, Yuji

    2017-04-01

    For non-invasive measurement of blood glucose level, attenuated total reflection (ATR) absorption spectroscopy system using a QCL as a light source was developed. The results of measurement of glucose solutions showed that the system had a sensitivity that was enough for blood glucose measurement. In-vivo measurement using the proposed system based on QCL showed that there was a correlation between absorptions measured with human lips and blood glucose level.

  5. Hepatic glucose output in humans measured with labeled glucose to reduce negative errors

    International Nuclear Information System (INIS)

    Levy, J.C.; Brown, G.; Matthews, D.R.; Turner, R.C.

    1989-01-01

    Steele and others have suggested that minimizing changes in glucose specific activity when estimating hepatic glucose output (HGO) during glucose infusions could reduce non-steady-state errors. This approach was assessed in nondiabetic and type II diabetic subjects during constant low dose [27 mumol.kg ideal body wt (IBW)-1.min-1] glucose infusion followed by a 12 mmol/l hyperglycemic clamp. Eight subjects had paired tests with and without labeled infusions. Labeled infusion was used to compare HGO in 11 nondiabetic and 15 diabetic subjects. Whereas unlabeled infusions produced negative values for endogenous glucose output, labeled infusions largely eliminated this error and reduced the dependence of the Steele model on the pool fraction in the paired tests. By use of labeled infusions, 11 nondiabetic subjects suppressed HGO from 10.2 +/- 0.6 (SE) fasting to 0.8 +/- 0.9 mumol.kg IBW-1.min-1 after 90 min of glucose infusion and to -1.9 +/- 0.5 mumol.kg IBW-1.min-1 after 90 min of a 12 mmol/l glucose clamp, but 15 diabetic subjects suppressed only partially from 13.0 +/- 0.9 fasting to 5.7 +/- 1.2 at the end of the glucose infusion and 5.6 +/- 1.0 mumol.kg IBW-1.min-1 in the clamp (P = 0.02, 0.002, and less than 0.001, respectively)

  6. Relationship between fluctuations in glucose levels measured by continuous glucose monitoring and vascular endothelial dysfunction in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Torimoto Keiichi

    2013-01-01

    Full Text Available Abstract Background Fluctuations in blood glucose level cause endothelial dysfunction and play a critical role in onset and/or progression of atherosclerosis. We hypothesized that fluctuation in blood glucose levels correlate with vascular endothelial dysfunction and that this relationship can be assessed using common bedside medical devices. Methods Fluctuations in blood glucose levels were measured over 24 hours by continuous glucose monitoring (CGM on admission day 2 in 57 patients with type 2 diabetes mellitus. The reactive hyperemia index (RHI, an index of vascular endothelial function, was measured using peripheral arterial tonometry (EndoPAT on admission day 3. Results The natural logarithmic-scaled RHI (L_RHI correlated with SD (r=−0.504; PPP=0.001 and percentage of time ≥200 mg/dl (r=−0.292; P=0.028. In 12 patients with hypoglycemia, L_RHI also correlated with the percentage of time at hypoglycemia (r=−0.589; P=0.044. L_RHI did not correlate with HbA1c or fasting plasma glucose levels. Furthermore, L_RHI did not correlate with LDL cholesterol, HDL cholesterol, and triglyceride levels or with systolic and diastolic blood pressures. Finally, multivariate analysis identified MAGE as the only significant determinant of L_RHI. Conclusions Fluctuations in blood glucose levels play a significant role in vascular endothelial dysfunction in type 2 diabetes. Trial registration UMIN000007581

  7. Development of standardized radioactive 46Sc solution

    International Nuclear Information System (INIS)

    Du Hongshan; Jia Zhang; Yu Yiguang; Sun Naiyao

    1988-01-01

    A method of preparation of standardized radioactive 46 Sc solution is developed. The separation of 46 Sc, the composition of 46 Sc solution and its stability, and radioactivity measurement of 46 Sc are systematically studied. The results obtained in the study and in the applications in many laboratories have shown that our method is effective and reliable

  8. A Model of Self-Monitoring Blood Glucose Measurement Error.

    Science.gov (United States)

    Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni; Cobelli, Claudio

    2017-07-01

    A reliable model of the probability density function (PDF) of self-monitoring of blood glucose (SMBG) measurement error would be important for several applications in diabetes, like testing in silico insulin therapies. In the literature, the PDF of SMBG error is usually described by a Gaussian function, whose symmetry and simplicity are unable to properly describe the variability of experimental data. Here, we propose a new methodology to derive more realistic models of SMBG error PDF. The blood glucose range is divided into zones where error (absolute or relative) presents a constant standard deviation (SD). In each zone, a suitable PDF model is fitted by maximum-likelihood to experimental data. Model validation is performed by goodness-of-fit tests. The method is tested on two databases collected by the One Touch Ultra 2 (OTU2; Lifescan Inc, Milpitas, CA) and the Bayer Contour Next USB (BCN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ). In both cases, skew-normal and exponential models are used to describe the distribution of errors and outliers, respectively. Two zones were identified: zone 1 with constant SD absolute error; zone 2 with constant SD relative error. Goodness-of-fit tests confirmed that identified PDF models are valid and superior to Gaussian models used so far in the literature. The proposed methodology allows to derive realistic models of SMBG error PDF. These models can be used in several investigations of present interest in the scientific community, for example, to perform in silico clinical trials to compare SMBG-based with nonadjunctive CGM-based insulin treatments.

  9. Effects of hyperglycemia on glucose production and utilization in humans. Measurement with [3H]-2-, [3H]-3-, and [14C]-6-glucose

    International Nuclear Information System (INIS)

    Bell, P.M.; Firth, R.G.; Rizza, R.A.

    1986-01-01

    Studies with tritiated isotopes of glucose have demonstrated that hyperglycemia per se stimulates glucose utilization and suppresses glucose production in humans. These conclusions rely on the assumption that tritiated glucose provides an accurate measure of glucose turnover. However, if in the presence of hyperglycemia the isotope either loses its label during futile cycling or retains its label during cycling through glycogen, then this assumption is not valid. To examine this question, glucose utilization and glucose production rates were measured in nine normal subjects with a simultaneous infusion of [ 3 H]-2-glucose, an isotope that may undergo futile cycling but does not cycle through glycogen; [ 14 C]-6-glucose, an isotope that may cycle through glycogen but does not futile cycle; and [ 3 H]-3-glucose, an isotope that can both undergo futile cycling and cycle through glycogen. In the postabsorptive state at plasma glucose concentration of 95 mg X dl-1, glucose turnover determined with [ 14 C]-6-glucose (2.3 +/- 0.1 mg X kg-1 X min-1) was greater than that determined with [3 3 H]glucose (2.1 +/- 0.1 mg X kg-1 X min-1, P = 0.002) and slightly less than that determined with [ 3 H]-2-glucose (2.7 +/- 0.2 mg X kg-1 X min-1, P = 0.08). Plasma glucose was then raised from 95 to 135 to 175 mg X dl-1 while insulin secretion was inhibited, and circulating insulin, glucagon, and growth hormone concentrations were maintained constant by infusion of these hormones and somatostatin. Glucose production and utilization rates determined with [ 14 C]-6-glucose continued to be less than those determined with [ 3 H]-2-glucose and greater than those seen with [ 3 H]-3-glucose

  10. Simultaneous measurement of glucose transport and utilization in the human brain

    Science.gov (United States)

    Shestov, Alexander A.; Emir, Uzay E.; Kumar, Anjali; Henry, Pierre-Gilles; Seaquist, Elizabeth R.

    2011-01-01

    Glucose is the primary fuel for brain function, and determining the kinetics of cerebral glucose transport and utilization is critical for quantifying cerebral energy metabolism. The kinetic parameters of cerebral glucose transport, KMt and Vmaxt, in humans have so far been obtained by measuring steady-state brain glucose levels by proton (1H) NMR as a function of plasma glucose levels and fitting steady-state models to these data. Extraction of the kinetic parameters for cerebral glucose transport necessitated assuming a constant cerebral metabolic rate of glucose (CMRglc) obtained from other tracer studies, such as 13C NMR. Here we present new methodology to simultaneously obtain kinetic parameters for glucose transport and utilization in the human brain by fitting both dynamic and steady-state 1H NMR data with a reversible, non-steady-state Michaelis-Menten model. Dynamic data were obtained by measuring brain and plasma glucose time courses during glucose infusions to raise and maintain plasma concentration at ∼17 mmol/l for ∼2 h in five healthy volunteers. Steady-state brain vs. plasma glucose concentrations were taken from literature and the steady-state portions of data from the five volunteers. In addition to providing simultaneous measurements of glucose transport and utilization and obviating assumptions for constant CMRglc, this methodology does not necessitate infusions of expensive or radioactive tracers. Using this new methodology, we found that the maximum transport capacity for glucose through the blood-brain barrier was nearly twofold higher than maximum cerebral glucose utilization. The glucose transport and utilization parameters were consistent with previously published values for human brain. PMID:21791622

  11. Evanescent Wave Absorption Based Fiber Sensor for Measuring Glucose Solution Concentration

    Science.gov (United States)

    Marzuki, Ahmad; Candra Pratiwi, Arni; Suryanti, Venty

    2018-03-01

    An optical fiber sensor based on evanescent wave absorption designed for measuring glucose solution consentration was proposed. The sensor was made to detect absorbance of various wavelength in the glucose solution. The sensing element was fabricated by side polishing of multimode polymer optical fiber to form a D-shape. The sensing element was immersed in different concentration of glucoce solution. As light propagated through the optical fiber, the evanescent wave interacted with the glucose solution. Light was absorbed by the glucose solution. The larger concentration the glucose solution has, the more the evanescent wave was absorbed in particular wavelenght. Here in this paper, light absorbtion as function of glucose concentration was measured as function of wavelength (the color of LED). We have shown that the proposed sensor can demonstrated an increase of light absorption as function of glucose concentration.

  12. A new device for production measurements of field integral and field direction of SC dipole magnets

    International Nuclear Information System (INIS)

    Preissner, H.; Bouchard, R.; Luethke, P.; Makulski, A.; Meinke, R.; Nesteruk, K.

    1990-01-01

    The performance of all superconducting magnets for HERA is tested in the DESY magnet test facility and their magnetic field is measured. For dipole magnets the magnitude and the direction of the field is measured point by point along the axis with a mole-type probe which is transported through the beam pipe. The positioning of the probe is done via a toothed belt with an accuracy of 1 mm. The probe houses two Hall probes perpendicular to each other, a gravitational tilt sensor and an NMR probe. The field in the plateau is measured by NMR, the fringe field is measured by the Hall probes and the field direction relative to gravity is obtained from the ratio of the two Hall voltages and the tilt sensor. The field integral is determined with an accuracy of 10 -4 and the average field direction is measured with an accuracy of 0.2 mrad. 4 refs., 4 figs

  13. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears.

    Science.gov (United States)

    Cha, Kyoung Ha; Jensen, Gary C; Balijepalli, Anant S; Cohan, Bruce E; Meyerhoff, Mark E

    2014-02-04

    Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 μM glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/μM and a limit of quantitation (LOQ) of 9 μM. The strips also exhibit ≤13% error (n = 3) for 25, 50, and 75 μM glucose in the presence of 10 μM acetaminophen, 100 μM ascorbic acid, and 100 μM uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 μM (mean = 47 μM, median = 43 μM), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.

  14. Intraperitoneal Glucose Sensing is Sometimes Surprisingly Rapid

    Directory of Open Access Journals (Sweden)

    Anders Lyngvi Fougner

    2016-04-01

    Full Text Available Rapid, accurate and robust glucose measurements are needed to make a safe artificial pancreas for the treatment of diabetes mellitus type 1 and 2. The present gold standard of continuous glucose sensing, subcutaneous (SC glucose sensing, has been claimed to have slow response and poor robustness towards local tissue changes such as mechanical pressure, temperature changes, etc. The present study aimed at quantifying glucose dynamics from central circulation to intraperitoneal (IP sensor sites, as an alternative to the SC location. Intraarterial (IA and IP sensors were tested in three anaesthetized non-diabetic pigs during experiments with intravenous infusion of glucose boluses, enforcing rapid glucose level excursions in the range 70--360 mg/dL (approximately 3.8--20 mmol/L. Optical interferometric sensors were used for IA and IP measurements. A first-order dynamic model with time delay was fitted to the data after compensating for sensor dynamics. Additionally, off-the-shelf Medtronic Enlite sensors were used for illustration of SC glucose sensing. The time delay in glucose excursions from central circulation (IA to IP sensor location was found to be in the range 0--26 s (median: 8.5 s, mean: 9.7 s, SD 9.5 s, and the time constant was found to be 0.5--10.2 min (median: 4.8 min, mean: 4.7 min, SD 2.9 min. IP glucose sensing sites have a substantially faster and more distinctive response than SC sites when sensor dynamics is ignored, and the peritoneal fluid reacts even faster to changes in intravascular glucose levels than reported in previous animal studies. This study may provide a benchmark for future, rapid IP glucose sensors.

  15. Glycolysis-induced discordance between glucose metabolic rates measured with radiolabeled fluorodeoxyglucose and glucose

    International Nuclear Information System (INIS)

    Ackermann, R.F.; Lear, J.L.

    1989-01-01

    We have developed an autoradiographic method for estimating the oxidative and glycolytic components of local CMRglc (LCMRglc), using sequentially administered [ 18 F]fluorodeoxyglucose (FDG) and [ 14 C]-6-glucose (GLC). FDG-6-phosphate accumulation is proportional to the rate of glucose phosphorylation, which occurs before the divergence of glycolytic (GMg) and oxidative (GMo) glucose metabolism and is therefore related to total cerebral glucose metabolism GMt: GMg + GMo = GMt. With oxidative metabolism, the 14 C label of GLC is temporarily retained in Krebs cycle-related substrate pools. We hypothesize that with glycolytic metabolism, however, a significant fraction of the 14 C label is lost from the brain via lactate production and efflux from the brain. Thus, cerebral GLC metabolite concentration may be more closely related to GMo than to GMt. If true, the glycolytic metabolic rate will be related to the difference between FDG- and GLC-derived LCMRglc. Thus far, we have studied normal awake rats, rats with limbic activation induced by kainic acid (KA), and rats visually stimulated with 16-Hz flashes. In KA-treated rats, significant discordance between FDG and GLC accumulation, which we attribute to glycolysis, occurred only in activated limbic structures. In visually stimulated rats, significant discordance occurred only in the optic tectum

  16. Measurement of the g factor of the 3.1232 MeV 19/2- level in 43Sc by perturbed angular distribution method

    International Nuclear Information System (INIS)

    Zhu Shengyun; Li Anli; Gou Zhenghui; Zheng Shengnan; Li Guangsheng

    1994-01-01

    The g-factor hence the magnetic moment, of the isomeric state 43 Sc(19/2 - , 3.1232 MeV) has been measured by the time differential perturbed angular distribution method. The measured values are g = 0.3279(19) and μ/μN = 3.108(18) nm

  17. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  18. Glucose Monitoring System Based on Osmotic Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Alexandra LEAL

    2011-02-01

    Full Text Available This paper presents the design and development of a prototype sensor unit for implementation in a long-term glucose monitoring system suitable for estimating glucose levels in people suffering from diabetes mellitus. The system utilizes osmotic pressure as the sensing mechanism and consists of a sensor prototype that is integrated together with a pre-amplifier and data acquisition unit for both data recording and processing. The sensor prototype is based on an embedded silicon absolute pressure transducer and a semipermeable nanoporous membrane that is enclosed in the sensor housing. The glucose monitoring system facilitates the integration of a low power microcontroller that is combined with a wireless inductive powered communication link. Experimental verification have proven that the system is capable of tracking osmotic pressure changes using albumin as a model compound, and thereby show a proof of concept for novel long term tracking of blood glucose from remote sensor nodes.

  19. "Common" lead isotopic measurements in silicate glasses and minerals by laser ablation double-focusing SC-ICPMS (2017)

    Data.gov (United States)

    Department of the Interior — This dataset is related to a 2017 journal article by A. J. Pietruszka and L. A. Neymark titled "Evaluation of laser ablation double-focusing SC-ICPMS for “common”...

  20. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    OpenAIRE

    Thomas, Felicity Louise; Signal, Mathew; Harris, Deborah L.; Weston, Philip J.; Harding, Jane E.; Shaw, Geoffrey M.; Chase, J. Geoffrey

    2014-01-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia me...

  1. Measurements of 14 MeV neutron radiative capture γ-ray spectra and integrated cross sections in Sc, Y, Pr and Ho

    International Nuclear Information System (INIS)

    Budnar, M.; Cvelbar, F.; Likar, A.; Martincic, R.; Potokar, M.; Ivkovic, V.

    1977-01-01

    Gamma ray spectra and integrated cross sections for radiative capture in 45 Sc, 89 Y, 141 Pr and 165 Ho have been measured. Obtained integrated cross sections (800+-110)μb, (1490+-210)μb, (980+-160)μb and (940+-150)μb are in accordance with measurements at other elements showing smooth mass dependence. Measuring procedure and experimental data evaluation is described in details. (author)

  2. Measurement of gluconeogenesis using glucose fragments and mass spectrometry after ingestion of deuterium oxide

    NARCIS (Netherlands)

    Chacko, Shaji K.; Sunehag, Agneta L.; Sharma, Susan; Sauer, Pieter J. J.; Haymond, Morey W.

    We report a new method to measure the fraction of glucose derived from gluconeogenesis using gas chromatography-mass spectrometry and positive chemical ionization. After ingestion of deuterium oxide by subjects, glucose derived from gluconeogenesis is labeled with deuterium. Our calculations of

  3. Measurement of gluconeogenesis using glucose fragments and mass spectrometry after ingestion of deuterium oxide.

    Science.gov (United States)

    We report a new method to measure the fraction of glucose derived from gluconeogenesis using gas chromatography-mass spectrometry and positive chemical ionization. After ingestion of deuterium oxide by subjects, glucose derived from gluconeogenesis is labeled with deuterium. Our calculations of gluc...

  4. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  5. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  6. Underestimation of glucose turnover measured with [6-3H]- and [6,6-2H]- but not [6-14C]glucose during hyperinsulinemia in humans

    International Nuclear Information System (INIS)

    McMahon, M.M.; Schwenk, W.F.; Haymond, M.W.; Rizza, R.A.

    1989-01-01

    Recent studies indicate that hydrogen-labeled glucose tracers underestimate glucose turnover in humans under conditions of high flux. The cause of this underestimation is unknown. To determine whether the error is time-, pool-, model-, or insulin-dependent, glucose turnover was measured simultaneously with [6-3H]-, [6,6-2H2]-, and [6-14C]glucose during a 7-h infusion of either insulin (1 mU.kg-1.min-1) or saline. During the insulin infusion, steady-state glucose turnover measured with both [6-3H]glucose (8.0 +/- 0.5 mg.kg-1.min-1) and [6,6-2H2]glucose (7.6 +/- 0.5 mg.kg-1.min-1) was lower (P less than .01) than either the glucose infusion rate required to maintain euglycemia (9.8 +/- 0.7 mg.kg-1.min-1) or glucose turnover determined with [6-14C]glucose and corrected for Cori cycle activity (9.8 +/- 0.7 mg.kg-1.min-1). Consequently negative glucose production rates (P less than .01) were obtained with either [6-3H]- or [6,6-2H2]- but not [6-14C]glucose. The difference between turnover estimated with [6-3H]glucose and actual glucose disposal (or 14C glucose flux) did not decrease with time and was not dependent on duration of isotope infusion. During saline infusion, estimates of glucose turnover were similar regardless of the glucose tracer used. High-performance liquid chromatography of the radioactive glucose tracer and plasma revealed the presence of a tritiated nonglucose contaminant. Although the contaminant represented only 1.5% of the radioactivity in the [6-3H]glucose infusate, its clearance was 10-fold less (P less than .001) than that of [6-3H]glucose. This resulted in accumulation in plasma, with the contaminant accounting for 16.6 +/- 2.09 and 10.8 +/- 0.9% of what customarily is assumed to be plasma glucose radioactivity during the insulin or saline infusion, respectively (P less than .01)

  7. In vivo measurements of brain glucose transport using the reversible michaelis-menten model and simultaneous measurements of cerebral blood flow changes during hypoglycemia

    OpenAIRE

    Choi, I.-Y.; Lee, S.-P.; Kim, S.-G.; Gruetter, R.

    2001-01-01

    Glucose is the major substrate that sustains normal brain function. When the brain glucose concentration approaches zero, glucose transport across the blood-brain barrier becomes rate limiting for metabolism during, for example, increased metabolic activity and hypoglycemia. Steady-state brain glucose concentrations in α-chloralose anesthetized rats were measured noninvasively as a function of plasma glucose. The relation between brain and plasma glucose was linear at 4.5 to 30 mmol/L plasma ...

  8. Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography

    Science.gov (United States)

    Chen, Tseng-Lin; Lo, Yu-Lung; Liao, Chia-Chi; Phan, Quoc-Hung

    2018-04-01

    A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index of aqueous glucose solutions with low and high scattering, respectively. It is shown that for both solutions, the optical rotation angle and depolarization index vary approximately linearly with the glucose concentration. As a result, the ability of the proposed method to obtain the glucose concentration by means of just two optical parameters is confirmed. The practical applicability of the proposed technique is demonstrated by measuring the optical rotation angle and depolarization index on the human fingertip of healthy volunteers under various glucose conditions.

  9. Generation of anti-idiotype scFv for pharmacokinetic measurement in lymphoma patients treated with chimera anti-CD22 antibody SM03.

    Directory of Open Access Journals (Sweden)

    Qi Zhao

    Full Text Available Pre-clinical and clinical studies of therapeutic antibodies require highly specific reagents to examine their immune responses, bio-distributions, immunogenicity, and pharmacodynamics in patients. Selective antigen-mimicking anti-idiotype antibody facilitates the assessment of therapeutic antibody in the detection, quantitation and characterization of antibody immune responses. Using mouse specific degenerate primer pairs and splenocytic RNA, we generated an idiotype antibody-immunized phage-displayed scFv library in which an anti-idiotype antibody against the therapeutic chimera anti-CD22 antibody SM03 was isolated. The anti-idiotype scFv recognized the idiotype of anti-CD22 antibody and inhibited binding of SM03 to CD22 on Raji cell surface. The anti-idiotype scFv was subsequently classified as Ab2γ type. Moreover, our results also demonstrated firstly that the anti-idiotype scFv could be used for pharmacokinetic measurement of circulating residual antibody in lymphoma patients treated with chimera anti-CD22 monoclonal antibody SM03. Of important, the present approach could be easily adopted to generate anti-idiotype antibodies for therapeutic antibodies targeting membrane proteins, saving the cost and time for producing a soluble antigen.

  10. Magnetic moment of {sup 48}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsubo, T., E-mail: tohtsubo@np.gs.niigata-u.ac.jp; Kawamura, Y.; Ohya, S. [Niigata University, Department of Physics (Japan); Izumikawa, T. [Niigata University, Radioisotope Center (Japan); Nishimura, K. [Toyama University, Faculty of Engineering (Japan); Muto, S. [Neutron Science Laboratory, KEK (Japan); Shinozuka, T. [Tohoku University, Cyclotron and Radioisotope Center (Japan)

    2007-11-15

    Nuclear magnetic resonances were measured for {sup 48}Sc and {sup 44m}Sc oriented at 8 mK in an Fe host metal. The magnetic hyperfine splitting frequencies at an external magnetic field of 0.2 T were determined to be 63.22(11) MHz and 64.81(1) MHz for {sup 48}Sc and {sup 44m}Sc, respectively. With the known magnetic moment of {mu}({sup 44m}Sc)=+3.88 (1) {mu}{sub N}, the magnetic moment of {sup 48}Sc is deduced as {mu}({sup 44}Sc)=+3.785(12) {mu}{sub N}. The measured magnetic moment of {sup 48}Sc is discussed in terms of the shell model using the effective interactions.

  11. Differential Mueller matrix polarimetry technique for non-invasive measurement of glucose concentration on human fingertip.

    Science.gov (United States)

    Phan, Quoc-Hung; Lo, Yu-Lung

    2017-06-26

    A differential Mueller matrix polarimetry technique is proposed for obtaining non-invasive (NI) measurements of the glucose concentration on the human fingertip. The feasibility of the proposed method is demonstrated by detecting the optical rotation angle and depolarization index of tissue phantom samples containing de-ionized water (DI), glucose solutions with concentrations ranging from 0~500 mg/dL and 2% lipofundin. The results show that the extracted optical rotation angle increases linearly with an increasing glucose concentration, while the depolarization index decreases. The practical applicability of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index properties of the human fingertips of healthy volunteers.

  12. Monitor of SC beam profiles

    CERN Document Server

    CERN PhotoLab

    1977-01-01

    A high-resolution secondary emission grid for the measurement of SC beam profiles. Modern techniques of metal-ceramic bonding, developed for micro-electronics, have been used in its construction. (See Annual Report 1977 p. 105 Fig. 12.)

  13. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Uemura, Mei

    2017-01-01

    Background: Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting h...

  14. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Mei Uemura; Yutaka Yano; Toshinari Suzuki; Taro Yasuma; Toshiyuki Sato; Aya Morimoto; Samiko Hosoya; Chihiro Suminaka; Hiromu Nakajima; Esteban C. Gabazza; Yoshiyuki Takei

    2017-01-01

    Background Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hy...

  15. The measurement of the nigrostriatal dopaminergic function and glucose metabolism in patients with movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Shima, Fumio; Kato, Motohiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1992-12-01

    The nigrostriatal dopaminergic function and glucose metabolism were evaluated in 34 patients with various movement disorders by using positron emission tomography with [sup 18]F-Dopa and [sup 18]F-FDG respectively. The [sup 18]F-Dopa uptake in the striatum (the caudate head and the putamen) decreased in patients with Parkinson's disease but was relatively unaffected in the caudate. The cerebral glucose metabolism was normal in patients with Parkinson's disease. The [sup 18]F-Dopa uptake in the striatum also decreased in cases of atypical parkinsonism and in cases of progressive supranuclear palsy, but there was no difference in the uptake between the caudate and the putamen. The glucose metabolism decreased in the cerebral hemisphere including the striatum; this finding was also different from those of Parkinson's disease. A normal [sup 18]F-Dopa uptake in the striatum with a markedly decreased striatal glucose metabolism and a mildly decreased cortical glucose metabolism was observed in cases of Huntington's disease and Wilson's disease. The [sup 18]F-Dopa uptake in the striatum increased and the glucose metabolism was normal in cases of idiopathic dystonia. Various patterns of [sup 18]F-Dopa uptake and glucose metabolism were thus observed in the various movement disorders. These results suggest that the measurements of the [sup 18]F-Dopa uptake and the cerebral glucose metabolism would be useful for the evaluation of the striatal function in various movement disorders. (author).

  16. Use of continuous glucose monitoring as an outcome measure in clinical trials.

    Science.gov (United States)

    Beck, Roy W; Calhoun, Peter; Kollman, Craig

    2012-10-01

    Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian(®) [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5-57 years; mean, 18 ± 12 years). Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P = 0.92), and the correlation of the two was high (r = 0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P = 0.05] and 262 mg/dL vs. 257 mg/dL [P = 0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; Pblood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials.

  17. Accuracy of Continuous Glucose Monitoring Measurements in Normo-Glycemic Individuals

    DEFF Research Database (Denmark)

    Akintola, Abimbola A; Noordam, Raymond; Jansen, Steffy W

    2015-01-01

    a 24-hour period. Validity of CGM-derived individual glucose measurements, calculated measures of glycemia over daytime (09:00h-23:00h) and nighttime (23:00h-09:00h), and calculated measures of glycemic variability (e.g. 24h standard deviation [SD]) were assessed by Pearson correlation coefficients......, mean absolute relative difference (MARD) and paired t-tests. RESULTS: The median correlation coefficient between CGM and venous glucose measurements per participant was 0.68 (interquartile range: 0.40-0.78), and the MARD was 17.6% (SD = 17%). Compared with venous sampling, the calculated measure...

  18. Requirements for Successful Adoption of a Glucose Measurement System Into a Hospital POC Program.

    Science.gov (United States)

    Füzéry, Anna K; Cembrowski, George S

    2016-07-01

    Widespread and successful implementation of any glucose measurement system in a hospital point-of-care (POC) program requires a number of features in addition to accurate and reliable analytical performance. Such features include, but are not limited to, a system's glucose-hematocrit dependence, durability, information technology capabilities, and battery capacity and battery life. While the study of Ottiger et al in this issue supports the analytical accuracy and reliability of Bayer's CONTOUR XT® blood glucose monitoring system, the suitability of other features of this system for a hospital POC program remains to be established. © 2016 Diabetes Technology Society.

  19. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bornø, Andreas; Foged, Lene; van Hall, Gerrit

    2014-01-01

    The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments...... of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose...

  20. [Designing and implementation of a web-based quality monitoring system for plasma glucose measurement in multicenter population study].

    Science.gov (United States)

    Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui

    2015-05-01

    The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.

  1. Requirements for Successful Adoption of a Glucose Measurement System Into a Hospital POC Program

    OpenAIRE

    F?z?ry, Anna K.; Cembrowski, George S.

    2016-01-01

    Widespread and successful implementation of any glucose measurement system in a hospital point-of-care (POC) program requires a number of features in addition to accurate and reliable analytical performance. Such features include, but are not limited to, a system?s glucose-hematocrit dependence, durability, information technology capabilities, and battery capacity and battery life. While the study of Ottiger et al in this issue supports the analytical accuracy and reliability of Bayer?s CONTO...

  2. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  3. A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva

    Directory of Open Access Journals (Sweden)

    Dong Geon Jung

    2017-11-01

    Full Text Available A lab-on-a-chip (LOC-based non-invasive optical sensor for measuring glucose in saliva was fabricated. Existing glucose sensors utilizing blood require acquisition of a blood sample by pricking the finger, which is painful and inconvenient. To overcome these limitations, we propose a non-invasive glucose sensor with LOC, micro-electro-mechanical system and optical measurement technology. The proposed sensor for measuring glucose in saliva involves pretreatment, mixing, and measurement on a single tiny chip. Saliva containing glucose and glucose oxidase for glucose oxidation are injected through Inlets 1 and 2, respectively. Next, H2O2 is produced by the reaction between glucose and glucose oxidase in the pretreatment part. The saliva and generated H2O2 are mixed with a colorizing agent injected through Inlet 3 during the mixing part and the absorbance of the colorized mixture is measured in the measurement part. The absorbance of light increases as a function of glucose concentration at a wavelength of 630 nm. To measure the absorbance of the colorized saliva, a light-emitting diode with a wavelength of 630 nm and a photodiode were used during the measurement part. As a result, the measured output current of the photodiode decreased as glucose concentration in the saliva increased.

  4. Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling.

    Science.gov (United States)

    Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Watanabe, Toshihiro; Maekawa, Yasunori; Isobe, Kazuki; Koike, Reona; Nakajima, Hiromu; Asano, Kaoru

    2011-12-01

    Monitoring postprandial hyperglycemia is crucial in treating diabetes, although its dynamics make accurate monitoring difficult. We developed a new technology for monitoring postprandial hyperglycemia using interstitial fluid (ISF) extraction technology without blood sampling. The glucose area under the curve (AUC) using this system was measured as accumulated ISF glucose (IG) with simultaneous calibration with sodium ions. The objective of this study was to evaluate this technological concept in healthy individuals. Minimally invasive ISF extraction technology (MIET) comprises two steps: pretreatment with microneedles and ISF accumulation over a specific time by contact with a solvent. The correlation between glucose and sodium ion levels using MIET was evaluated in 12 subjects with stable blood glucose (BG) levels during fasting. BG and IG time courses were evaluated in three subjects to confirm their relationship while BG was fluctuating. Furthermore, the accuracy of glucose AUC measurements by MIET was evaluated several hours after a meal in 30 subjects. A high correlation was observed between glucose and sodium ion levels when BG levels were stable (R=0.87), indicating that sodium ion is a good internal standard for calibration. The variation in IG and BG with MIET was similar, indicating that IG is an adequate substitute for BG. Finally, we showed a strong correlation (R=0.92) between IG-AUC and BG-AUC after a meal. These findings validate the adequacy of glucose AUC measurements using MIET. Monitoring glucose using MIET without blood sampling may be beneficial to patients with diabetes.

  5. Measuring glucose cerebral metabolism in the healthy mouse using hyperpolarized C-13 magnetic resonance

    DEFF Research Database (Denmark)

    Mishkovsky, Mor; Anderson, Brian; Karlsson, Magnus

    2017-01-01

    The mammalian brain relies primarily on glucose as a fuel to meet its high metabolic demand. Among the various techniques used to study cerebral metabolism, C-13 magnetic resonance spectroscopy (MRS) allows following the fate of C-13-enriched substrates through metabolic pathways. We herein...... glucose is split into 3-carbon intermediates by aldolase. This unique method allows direct detection of glycolysis in vivo in the healthy brain in a noninvasive manner....... demonstrate that it is possible to measure cerebral glucose metabolism in vivo with sub-second time resolution using hyperpolarized C-13 MRS. In particular, the dynamic C-13-labeling of pyruvate and lactate formed from C-13-glucose was observed in real time. An ad-hoc synthesis to produce [2,3,4,6,6-H-2(5), 3...

  6. Double-label autoradiographic deoxyglucose method for sequential measurement of regional cerebral glucose utilization

    Energy Technology Data Exchange (ETDEWEB)

    Redies, C; Diksic, M; Evans, A C; Gjedde, A; Yamamoto, Y L

    1987-08-01

    A new double-label autoradiographic glucose analog method for the sequential measurement of altered regional cerebral metabolic rates for glucose in the same animal is presented. This method is based on the sequential injection of two boluses of glucose tracer labeled with two different isotopes (short-lived /sup 18/F and long-lived /sup 3/H, respectively). An operational equation is derived which allows the determination of glucose utilization for the time period before the injection of the second tracer; this equation corrects for accumulation and loss of the first tracer from the metabolic pool occurring after the injection of the second tracer. An error analysis of this operational equation is performed. The double-label deoxyglucose method is validated in the primary somatosensory (''barrel'') cortex of the anesthetized rat. Two different rows of whiskers were stimulated sequentially in each rat; the two periods of stimulation were each preceded by an injection of glucose tracer. After decapitation, dried brain slices were first exposed, in direct contact, to standard X-ray film and then to uncoated, ''tritium-sensitive'' film. Results show that the double-label deoxyglucose method proposed in this paper allows the quantification and complete separation of glucose utilization patterns elicited by two different stimulations sequentially applied in the same animal.

  7. The measurement of the nigrostriatal dopaminergic function and glucose metabolism in patients with movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Shima, Fumio; Kato, Motohiro (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-12-01

    The nigrostriatal dopaminergic function and glucose metabolism were evaluated in 34 patients with various movement disorders by using positron emission tomography with [sup 18]F-Dopa and [sup 18]F-FDG respectively. The [sup 18]F-Dopa uptake in the striatum (the caudate head and the putamen) decreased in patients with Parkinson's disease but was relatively unaffected in the caudate. The cerebral glucose metabolism was normal in patients with Parkinson's disease. The [sup 18]F-Dopa uptake in the striatum also decreased in cases of atypical parkinsonism and in cases of progressive supranuclear palsy, but there was no difference in the uptake between the caudate and the putamen. The glucose metabolism decreased in the cerebral hemisphere including the striatum; this finding was also different from those of Parkinson's disease. A normal [sup 18]F-Dopa uptake in the striatum with a markedly decreased striatal glucose metabolism and a mildly decreased cortical glucose metabolism was observed in cases of Huntington's disease and Wilson's disease. The [sup 18]F-Dopa uptake in the striatum increased and the glucose metabolism was normal in cases of idiopathic dystonia. Various patterns of [sup 18]F-Dopa uptake and glucose metabolism were thus observed in the various movement disorders. These results suggest that the measurements of the [sup 18]F-Dopa uptake and the cerebral glucose metabolism would be useful for the evaluation of the striatal function in various movement disorders. (author).

  8. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  9. Childhood cardiorespiratory fitness, muscular fitness and adult measures of glucose homeostasis.

    Science.gov (United States)

    Fraser, Brooklyn J; Blizzard, Leigh; Schmidt, Michael D; Juonala, Markus; Dwyer, Terence; Venn, Alison J; Magnussen, Costan G

    2018-02-14

    To assess whether childhood cardiorespiratory fitness (CRF) and muscular fitness phenotypes (strength, power, endurance) predict adult glucose homeostasis measures. Prospective longitudinal study. Study examining participants who had physical fitness measured in childhood (aged 7-15 years) and who attended follow-up clinics approximately 20 years later and provided a fasting blood sample which was tested for glucose and insulin. Physical fitness measurements included muscular strength (right and left grip, shoulder flexion, shoulder and leg extension), power (standing long jump distance) and endurance (number of push-ups in 30s), and CRF (1.6km run duration). In adulthood, fasting glucose and insulin levels were used to derive glucose homeostasis measures of insulin resistance (HOMA2-IR) and beta cell function (HOMA2-β). A standard deviation increase in childhood CRF or muscular strength (males) was associated with fasting glucose (CRF: β=-0.06mmol/L), fasting insulin (CRF: β=-0.73mU/L; strength: β=-0.40mU/L), HOMA2-IR (CRF: β=-0.06; strength: β=-0.05) and HOMA2-β (CRF: β=-3.06%; strength: β=-2.62%) in adulthood, independent of the alternative fitness phenotype (all p0.06). CRF and muscular fitness in childhood were inversely associated with measures of fasting insulin, insulin resistance and beta cell function in adulthood. Childhood CRF and muscular fitness could both be potential independent targets for strategies to help reduce the development of adverse glucose homeostasis. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Blood glucose measurement with multiple quantum cascade lasers using hollow-optical fiber-based ATR spectroscopy

    Science.gov (United States)

    Yoshioka, K.; Kino, S.; Matsuura, Y.

    2018-02-01

    For non-invasive blood glucose measurement, a measurement system based on mid-infrared ATR spectroscopy equipped with a combination of a QCL as a light source and a hollow-optical fiber as a beam delivery medium is developed. Firstly the measurement sensitivity of the system is evaluated by using glucose solutions and the result shows a significant correlation between optical absorbance and solution concentration. It is also confirmed that the system has a sensitivity that is enough for blood glucose measurement. Then optical absorption of human lips in the mid-infrared wavelength region is measured using a QCL with a wavenumber of 1080 cm-1 where human tissue exhibits strong absorption of glucose and its metabolites. As a result, the measured absorption follows the change of blood glucose well with a time delay of around 10 minutes and correlation factor between the absorbance and the blood glucose level is 0.42.

  11. The cross section measurements for the 51V(n, α)48Sc and 51V(n,p)51Ti reactions

    International Nuclear Information System (INIS)

    Hu Shangbin; Kong Xiangzhong; Yang Jingkang

    1999-01-01

    The cross sections for 51 V(n, α) 48 Sc and 51 V(n,p) 51 Ti have been measured by using the activation method relative to the cross sections of 27 Al(n, α) 24 Na in the neutron energy range 13.4 --14.8 MeV. The results are compared with the published data. The neutron energies were determined by the method of cross section ratios for the reactions 90 Zr(n.2n) 89 Zr by 93 Nb(n,2n) 92m Nb

  12. Full polarization measurement of SR emitted from twin helical undulators using Sc/Cr multilayers at 398.6 eV

    International Nuclear Information System (INIS)

    Hirono, T.; Kimura, H.; Muro, T.; Saitoh, Y.; Ishikawa, T.

    2004-01-01

    Full text: Many of scientific measurements utilizing the polarization characteristics such as MCD are vigorously studied in soft x-ray region. To obtain polarization state precisely is important to study physical phenomena quantitatively. For example, using information of accurate polarization state of probe beam we are able to discuss not only a structure of spectrum but also absolute value of measured data. We carried out the full polarization measurements at BL25SU in SPring-8. The measurements were performed for synchrotron radiation (SR) beam of 398.6 eV emitted from twin helical undulators. All parameters of polarization state of the beam were determined with phase shifting transmission multilayer and polarizing reflection multilayer. The phase shifter was a newly developed Sc/Cr multilayer and was evaluated as a quarter-wave plate. In the presentation, we will report the full polarization measurement of circularly polarized light using the quarter-wave plate

  13. Precision and accuracy of blood glucose measurements using three different instruments.

    Science.gov (United States)

    Nowotny, B; Nowotny, P J; Strassburger, K; Roden, M

    2012-02-01

    Assessment of insulin sensitivity by dynamic metabolic tests such as the hyperinsulinemic euglycemic clamp critically relies on the reproducible and fast measurement of blood glucose concentrations. Although various instruments have been developed over the last decades, little is known as to the accuracy and comparability. We therefore compared the best new instrument with the former gold standard instruments to measure glucose concentrations in metabolic tests. Fasting blood samples of 15 diabetic and 10 healthy subjects were collected into sodium-fluoride tubes, spiked with glucose (0, 2.8, 6.9 and 11.1 mmol/l) and measured either as whole blood (range 3.3-26.3 mmol/l) or following centrifugation as plasma (range 3.9-32.0 mmol/l). Plasma samples were analyzed in the YSI-2300 STAT plus (YSI), EKF Biosen C-Line (EKF) and the reference method, Beckman Glucose analyzer-II (BMG), whole blood samples in EKF instruments with YSI as reference method. The average deviation of the EKF from the reference, BMG, was 3.0 ± 3.5% without any concentration-dependent variability. Glucose measurements by YSI were in good agreement with that by BMG (plasma) and EKF (plasma and whole blood) up to concentrations of 13.13 mmol/l (0.5 ± 3.7%), but deviation increased to -6.2 ± 3.8% at higher concentrations. Precision (n = 6) was ±2.2% (YSI), ±3.9% (EKF) and ±5.2% (BMG). The EKF instrument is comparable regarding accuracy and precision to the reference method BMG and can be used in metabolic tests, while the YSI showed a systematic shift at higher glucose concentrations. Based on these results we decided to replace BMG with EKF instrument in metabolic tests. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  14. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  15. A simple method for measuring glucose utilization of insulin-sensitive tissues by using the brain as a reference

    International Nuclear Information System (INIS)

    Namba, Hiroki; Nakagawa, Keiichi; Iyo, Masaomi; Fukushi, Kiyoshi; Irie, Toshiaki

    1994-01-01

    A simple method, without measurement of the plasma input function, to obtain semiquantitative values of glucose utilization in tissues other than the brain with radioactive deoxyglucose is reported. The brain, in which glucose utilization is essentially insensitive to plasma glucose and insulin concentrations, was used as an internal reference. The effects of graded doses of oral glucose loading (0.5, 1 and 2 mg/g body weight) on insulin-sensitive tissues (heart, muscle and fat tissue) were studied in the rat. By using the brain-reference method, dose-dependent increases in glucose utilization were clearly shown in all the insulin-sensitive tissues examined. The method seems to be of value for measurement of glucose utilization using radioactive deoxyglucose and positron emission tomography in the heart or other insulin-sensitive tissues, especially during glucose loading. (orig.)

  16. Glucose metabolism in chronic diabetic foot ulcers measured in vivo using microdialysis

    DEFF Research Database (Denmark)

    Simonsen, L; Holstein, P; Larsen, K

    1998-01-01

    Ten subjects with diabetes mellitus and unilateral chronic foot ulcer were investigated. Local tissue concentrations of glucose and lactate were measured using the microdialysis method at a distance of 0.5-1 cm from the edge of the ulcer and in normal skin in the contralateral foot. Subcutaneous...

  17. Study on the mechanism of human blood glucose concentration measuring using mid-infrared spectral analysis technology

    Science.gov (United States)

    Li, Xiang

    2016-10-01

    All forms of diabetes increase the risk of long-term complications. Blood glucose monitoring is of great importance for controlling diabetes procedure, preventing the complications and improving the patient's life quality. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. The mid-infrared spectral region contains strong characteristic and well-defined absorption bands. Therefore, mid-infrared provides an opportunity for monitoring blood glucose invasively with only a few discrete bonds. Although the blood glucose concentration measurement using mid-infrared spectroscopy has a lot of advantages, the disadvantage is also obvious. The absorption in this infrared region is fundamental molecular group vibration. Absorption intensity is very strong, especially for biological molecules. In this paper, it figures out that the osmosis rate of glucose has a certain relationship with the blood glucose concentration. Therefore, blood glucose concentration could be measured indirectly by measuring the glucose exudate in epidermis layer. Human oral glucose tolerance tests were carried out to verify the correlation of glucose exudation in shallow layer of epidermis layer and blood glucose concentration. As it has been explained above, the mid-infrared spectral region contains well-defined absorption bands, the intensity of absorption peak around 1123 cm-1 was selected to measure the glucose and that around 1170 cm-1 was selected as reference. Ratio of absorption peak intensity was recorded for each set of measurement. The effect and importance of the cleaning the finger to be measured before spectrum measuring are discussed and also verified by experiment.

  18. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  19. MicroRNA Expression Varies according to Glucose Tolerance, Measurement Platform, and Biological Source

    Directory of Open Access Journals (Sweden)

    S. Dias

    2017-01-01

    Full Text Available Dysregulated microRNA (miRNA expression is observed during type 2 diabetes (T2D, although the consistency of miRNA expression across measurement platform and biological source is uncertain. Here we report miRNA profiling in the whole blood and serum of South African women with different levels of glucose tolerance, using next generation sequencing (NGS and quantitative real time PCR (qRT-PCR. Whole blood-derived miRNAs from women with newly diagnosed T2D (n=4, impaired glucose tolerance (IGT (n=4, and normal glucose tolerance (NGT (n=4 were subjected to NGS, whereafter transcript levels of selected miRNAs were quantified in the whole blood and serum of these women using qRT-PCR. Of the five significantly differentially expressed miRNAs identified by NGS, only the directional increase of miR-27b in women with IGT compared to NGT was confirmed in whole blood and serum, using qRT-PCR. Functional enrichment of miR-27b gene targets identified biological pathways associated with glucose transport and insulin regulation. In conclusion, this study showed poor correlation in miRNA expression profiled using NGS and qRT-PCR and in whole blood and serum. The consistent increased expression of miR-27b in women with IGT compared to NGT across measurement platform and biological source holds potential as a biomarker for risk stratification in our population.

  20. The Unscented Kalman Filter estimates the plasma insulin from glucose measurement.

    Science.gov (United States)

    Eberle, Claudia; Ament, Christoph

    2011-01-01

    Understanding the simultaneous interaction within the glucose and insulin homeostasis in real-time is very important for clinical treatment as well as for research issues. Until now only plasma glucose concentrations can be measured in real-time. To support a secure, effective and rapid treatment e.g. of diabetes a real-time estimation of plasma insulin would be of great value. A novel approach using an Unscented Kalman Filter that provides an estimate of the current plasma insulin concentration is presented, which operates on the measurement of the plasma glucose and Bergman's Minimal Model of the glucose insulin homeostasis. We can prove that process observability is obtained in this case. Hence, a successful estimator design is possible. Since the process is nonlinear we have to consider estimates that are not normally distributed. The symmetric Unscented Kalman Filter (UKF) will perform best compared to other estimator approaches as the Extended Kalman Filter (EKF), the simplex Unscented Kalman Filter (UKF), and the Particle Filter (PF). The symmetric UKF algorithm is applied to the plasma insulin estimation. It shows better results compared to the direct (open loop) estimation that uses a model of the insulin subsystem. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Measurement of (n,2n) cross-sections for Sc, Mn, Cr and In between 12 and 19 MeV with activation technique

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, S.; Win, Than; Matsuyama, S. [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Odano, N.

    1997-03-01

    Activation cross-sections for scandium, manganese, chromium and indium have been measured in the neutron energies from 12 to 19 MeV. Source neutrons were produced via the T(d,n){sup 4}He reaction by bombarding a 3.2-MeV deuteron beam from the Dynamitron accelerator of Fast Neutron Laboratory at Tohoku University. Ten packages of high or ultra-high purity metal foils for chromium and indium, alloy foils for manganese, and oxide powder for scandium were set around the neutron source at 5 cm from the target in the angular range from 0 to 140 deg covering the incident neutron energies from 19 to 12 MeV at the center position of each package. Activation rates of the samples were obtained by the gamma-ray measurements using a high purity germanium detector. Neutron flux at each sample was determined using the activation rates of two niobium foils locating both sides of that sample; the reference reaction was {sup 93}Nb(n,2n){sup 92m}Nb of which cross-section data was taken from the 1991 NEANDC/INDC standard files. The source neutrons distributions have been measured in detail by the time-of-flight technique. The measured cross-sections are the following important dosimetry or activation reactions: {sup 45}Sc(n,2n){sup 44m}Sc, {sup 55}Mn(n,2n){sup 54}Mn, {sup 52}Cr(n,2n){sup 51}Cr, and {sup 115}In(n,2n){sup 114m}In. These cross-sections are compared with available activation file, dosimetry files and previous experimental data. (author)

  2. Measurement of glucose utilization by Pseudomonas fluorescens that are free-living and that are attached to surfaces

    International Nuclear Information System (INIS)

    Fletcher, M.

    1986-01-01

    The assimilation and respiration of glucose by attached and free-living Pseudomonas fluorescens were compared. The attachment surfaces were polyvinylidene fluoride, polyethylene, and glass. Specific uptake of [ 1 C]glucose was determined after bacterial biomass was measured by (1) microscopic counts or (2) prelabelling of cells by providing [ 3 H]leucine as substrate, followed by dual-labelling scintillation counting. The glucose concentration was 1.4, 3.5, 5.5, 7.6, or 9.7 μM. Glucose assimilation by cells which became detached from the surfaces during incubation with glucose was also measured after the detached cells were collected by filtration. The composition of the substratum had no effect on the amount of glucose assimilated by attached cells. Glucose assimilation by attached cells exceeded that by free-living cells by a factor of between 2 and 5 or more, and respiration of glucose by surface-associated cells was greater than that by free-living bacteria. Glucose assimilation by detached cells was greater than that by attached bacteria. Measurements of biomass by microscopic counts gave more consistent results than those obtained with dual-labelling, but in general, results obtained by both methods were corroborative

  3. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients.

    Science.gov (United States)

    Uemura, Mei; Yano, Yutaka; Suzuki, Toshinari; Yasuma, Taro; Sato, Toshiyuki; Morimoto, Aya; Hosoya, Samiko; Suminaka, Chihiro; Nakajima, Hiromu; Gabazza, Esteban C; Takei, Yoshiyuki

    2017-08-01

    Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity. We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day. Copyright © 2017 Korean Diabetes Association

  4. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Mei Uemura

    2017-07-01

    Full Text Available BackgroundContinuous glucose monitoring (CGM is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET. Here we evaluated the accuracy of interstitial fluid glucose (IG AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference.MethodsThirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. ResultsA significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76 and nighttime (r=0.82. The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity.ConclusionWe showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day.

  5. Determination of NIR informative wavebands for transmission non-invasive blood glucose measurement using a Fourier transform spectrometer

    Science.gov (United States)

    Yang, Wenming; Liao, Ningfang; Cheng, Haobo; Li, Yasheng; Bai, Xueqiong; Deng, Chengyang

    2018-03-01

    Non-invasive blood glucose measurement using near infrared (NIR) spectroscopy relies on wavebands that provide reliable information about spectral absorption. In this study, we investigated wavebands which are informative for blood glucose in the NIR shortwave band (900˜1450 nm) and the first overtone band (1450˜1700 nm) through a specially designed NIR Fourier transform spectrometer (FTS), which featured a test fixture (where a sample or subject's finger could be placed) and all-reflective optics, except for a Michelson structure. Different concentrations of glucose solution and seven volunteers who had undergone oral glucose tolerance tests (OGTT) were studied to acquire transmission spectra in the shortwave band and the first overtone band. Characteristic peaks of glucose absorption were identified from the spectra of glucose aqueous solution by second-order derivative processing. The wavebands linked to blood glucose were successfully estimated through spectra of the middle fingertip of OGTT participants by a simple linear regression and correlation coefficient. The light intensity difference showed that glucose absorption in the first overtone band was much more prominent than it was in the shortwave band. The results of the SLR model established from seven OGTTs in total on seven participants enabled a positive estimation of the glucose-linked wavelength. It is suggested that wavebands with prominent characteristic peaks, a high correlation coefficient between blood glucose and light intensity difference and a relatively low standard deviation of predicted values will be the most informative wavebands for transmission non-invasive blood glucose measurement methods. This work provides a guidance for waveband selection for the development of non-invasive NIR blood glucose measurement.

  6. Measurement of Gamow-Teller and spin dipole strength in the 45Sc(n,p)45Ca reaction at 198 MeV

    International Nuclear Information System (INIS)

    Alford, W.P.; Celler, A.; Brown, B.A.; Long, S.; Raywood, K.

    1990-11-01

    The reaction 45 Sc(n,p) 45 Ca has been studied at an energy of 198 MeV with energy resolution of about 1 MeV. Measurements were carried out at nominal angles 0, 3, 6, 9, 12, 15, and 18 degrees and spectra obtained up to ∼40 MeV excitation energy in 45 Ca. Significant Gamow-Teller strength is observed at an excitation energy of about 7 MeV, somewhat higher than predicted by shell model calculations. The strength observed is in agreement with calculations using g A /g V ≅ 1. The spin dipole giant resonance is seen with centroid at about 15 MeV excitation and total cross section of 25 mb/sr at an angle of 6 degrees. (Author) (22 refs., 9 figs.)

  7. Successful microsurgical lip replantation: Monitoring venous congestion by blood glucose measurements in the replanted lip

    OpenAIRE

    Kazufumi Tachi; Masanori Mori; Reiko Tsukuura; Rintaro Hirai

    2018-01-01

    Replantation of an amputated lip using microvascular anastomosis is the best option for restoration of the defect. However, the amputated region often lacks veins with appropriate diameters for microvascular anastomoses and typically necessitates both postoperative exsanguination using medicinal leeches and a blood transfusion. We present a case of the successful replantation of an avulsed lip in which postoperative congestion was evaluated objectively by measuring blood glucose levels in the...

  8. Noninvasive measurement of regional myocardial glucose metabolism by positron emission computed tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.

    While the results of regional myocardial glucose metabolism measurements using positron emission computed tomography ( 13 N-ammonia) are promising, their utility and value remains to be determined in man. If this technique can be applied to patients with acute myocardial ischemia or infarction it may permit delineation of regional myocardial segments with altered, yet still active metabolism. Further, it may become possible to evaluate the effects of interventions designed to salvage reversibly injured myocardium by this technique

  9. CERN: SC-33

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    On 22 April a forward-looking CERN also looked back for a day, when the 'SC-33' event reviewed the achievements of CERN's first machine, the 600 MeV SynchroCyclotron (SC), which closed down on 17 December after 33 years of valiant service

  10. CERN: SC-33

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1991-06-15

    On 22 April a forward-looking CERN also looked back for a day, when the 'SC-33' event reviewed the achievements of CERN's first machine, the 600 MeV SynchroCyclotron (SC), which closed down on 17 December after 33 years of valiant service.

  11. S-C Mylonites

    NARCIS (Netherlands)

    Lister, G.S.; Snoke, A.W.

    1984-01-01

    Two types of foliations are commonly developed in mylonites and mylonitic rocks: (a) S-surfaces related to the accumulation of finite strain and (b) C-surfaces related to displacement discontinuities or zones of relatively high shear strain. There are two types of S-C mylonites. Type I S-C

  12. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  13. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    Science.gov (United States)

    Thomas, Felicity; Signal, Mathew; Harris, Deborah L; Weston, Philip J; Harding, Jane E; Shaw, Geoffrey M; Chase, J Geoffrey

    2014-05-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia metrics in newborn infants. Data from 155 babies were used. Two timing and 3 BG meter error models (Abbott Optium Xceed, Roche Accu-Chek Inform II, Nova Statstrip) were created using empirical data. Monte-Carlo methods were employed, and each simulation was run 1000 times. Each set of patient data in each simulation had randomly selected timing and/or measurement error added to BG measurements before CGM data were calibrated. The number of hypoglycemic events, duration of hypoglycemia, and hypoglycemic index were then calculated using the CGM data and compared to baseline values. Timing error alone had little effect on hypoglycemia metrics, but measurement error caused substantial variation. Abbott results underreported the number of hypoglycemic events by up to 8 and Roche overreported by up to 4 where the original number reported was 2. Nova results were closest to baseline. Similar trends were observed in the other hypoglycemia metrics. Errors in blood glucose concentration measurements used for calibration of CGM devices can have a clinically important impact on detection of hypoglycemia. If CGM devices are going to be used for assessing hypoglycemia it is important to understand of the impact of these errors on CGM data. © 2014 Diabetes Technology Society.

  14. Effects of glucose and insulin levels on adipose tissue glucose measurement by microdialysis probes retained for three weeks in Type 1 diabetic patients

    NARCIS (Netherlands)

    Hullegie, LM; Lutgers, HL; Dullaart, RPF; Sluiter, WJ; Wientjes, KJ; Schoonen, AJM; Hoogenberg, K

    Background: To evaluate the effects of acute hyperglycaemia and hyperinsulinaemia on adipose tissue glucose measurements by microdialysis probes inserted for a 3-week period. Methods: Microdialysis probes were implanted pairwise in abdominal adipose tissue in seven Type 1 diabetic patients and

  15. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  16. Successful microsurgical lip replantation: Monitoring venous congestion by blood glucose measurements in the replanted lip

    Directory of Open Access Journals (Sweden)

    Kazufumi Tachi

    2018-03-01

    Full Text Available Replantation of an amputated lip using microvascular anastomosis is the best option for restoration of the defect. However, the amputated region often lacks veins with appropriate diameters for microvascular anastomoses and typically necessitates both postoperative exsanguination using medicinal leeches and a blood transfusion. We present a case of the successful replantation of an avulsed lip in which postoperative congestion was evaluated objectively by measuring blood glucose levels in the replanted region. The patient presented to our hospital with an upper lip avulsion that was caused by a dog bite. The lip was replanted by the microvascular anastomoses of one artery and two veins using interposed vein grafts. The replanted lip showed signs of congestion on postoperative day one; exsanguination using medicinal leeches was attempted, while blood glucose levels were measured every three hours. Critical congestion, which did not occur in this patient, was defined as a blood glucose level lower than 40 mg/dL. Lip replantation was successful without any complications in this patient.

  17. [A non-invasive glucose measurement method based on orthogonal twin-polarized light and its pilot experimental investigation].

    Science.gov (United States)

    Wang, Hong; Wu, Baoming; Liu, Ding

    2010-04-01

    In order to overcome the existing shortcomings of the non-invasive blood glucose polarized light measurement methods of optical heterodyne detection and direct detection, we present in this paper a new orthogonal twin-polarized light (OTPL) non-invasive blood glucose measurement method, which converts the micro-angle rotated by an optical active substance such as glucose to the energy difference of OTPL, amplifies the signals by the high-sensitivity lock-in amplifier made of relevant principle, controls Faraday coil current to compensate the changes in deflection angle caused by blood glucose, and makes use of the linear relationship between blood glucose concentration and Faraday coil current to calculate blood glucose concentration. In our comparative experiment using the data measured by LX-20 automatic biochemical analyzer as a standard, a 0.9777 correlation coefficient is obtained in glucose concentration experiment, and a 0.952 in serum experiment. The result shows that this method has higher detection sensitivity and accuracy and lays a foundation for the development of practical new type of non-invasive blood glucose tester for diabetic patients.

  18. Measurement of Non-Invasive Blood Glucose Level Based Sensor Color TCS3200 and Arduino

    Science.gov (United States)

    Kurniadi Wardana, Humaidillah; Indahwati, Elly; Arifah Fitriyah, Lina

    2018-04-01

    Design and measurement of Arduino-based urinary (non-invasive) urine glucose using RGB tcs3200 sensor. This research was conducted by making use of the urine in diabetes patients detected by sensor colours then measured levels of colour based on the RGB colour of the urine of diabetics. The detection is done on 4 urine samples with each consisting of 3 diabetics and 1 non-diabetics. Equipment used in this research, among others, Arduino Uno, colour sensor tcs3200, LCD 16x4. The results showed that the detection of RGB values in diabetics 230 with blue and not diabetics 200 with red.

  19. Biosensor-based analyser. Measurement of glucose, sucrose, lactose, L-lactate and alcohol

    Energy Technology Data Exchange (ETDEWEB)

    Williams, F.T. Jr. (YSI, Inc., Yellow Springs, OH (United States))

    1992-05-01

    This paper describes an instrument, the YSI 2700, for the measurement of glucose, sucrose, lactose, L-lactate, and alcohol by means of biosensors. Each biosensor consists of an amperometric, hydrogen peroxide sensitive electrode combined with an immobilized oxidase enzyme trapped between two membranes. Each biosensor differs from the others only in its enzyme layer. The instrument can be used to measure these analytes in complex sample matrices; often directly, e.g. in whole blood and fermentations, after dilution with water, e.g. in molasses and corn syrup, or after extraction into water, e.g. in cheese and cereal products. (orig.).

  20. Application of a method based on the measurement of radiation reflectance when estimating the sensitivity of selected grain maize hybrids to the herbicide CALLISTO 480 SC + ATPLUS 463

    Directory of Open Access Journals (Sweden)

    Michal Vondra

    2009-01-01

    Full Text Available The application of methods based on measurements of photosynthesis efficiency is now more and more popular and used not only for the evaluation of the efficiency of herbicides but also for the estimation of their phytotoxicity to the cultivated crop. These methods enable to determine also dif­fe­ren­ces in the sensitivity of cultivars and/or hybrids to individual herbicides. The advantage of these methods consists above all in the speed and accuracy of measuring.In a field experiment, the sensitivity of several selected grain maize hybrids (EDENSTAR, NK AROBASE, NK LUGAN, LG 33.30 and NK THERMO to the herbicide CALLISTO 480 SC + ATPLUS 463 was tested for a period of three years. The sensitivity to a registered dose of 0.25 l . ha−1 + 0.5 % was measured by means of the apparatus PS1 meter, which could measure the reflected radiation. Measurements of sensitivity of hybrids were performed on the 2nd, 3rd, 4th, 5th and 8th day after the application of the tested herbicide, i.e. in the growing stage of the 3rd–5th leaf. Plant material was harvested using a small-plot combine harvester SAMPO 2010. Samples were weighed and converted to the yield with 15 % of moisture in grain DM.The obtained three-year results did not demonstrate differences in sensitivity of tested hybrids to the registered dose of the herbicide CALLISTO 480 SC + ATPLUS 463 (i.e. 0.25 l . ha−1 + 0,5 %. Recorded results indicated that for the majority of tested hybrids the most critical were the 4th and the 5th day after the application; on these days the average PS1 values were the highest at all. In years 2005 and 2007, none of the tested hybrids exceeded the limit value 15 (which indicated a certain decrease in the efficiency of photosynthesis. Although in 2006 three of tested hybrids showed a certain decrease in photosynthetic activity (i.e. EDENSTAR and NK AROBASE on the 3rd day and NK LUGAN on the 2nd–4th day after the application, no visual symptoms

  1. [Joint effect of birth weight and obesity measures on abnormal glucose metabolism at adulthood].

    Science.gov (United States)

    Xi, Bo; Cheng, Hong; Chen, Fangfang; Zhao, Xiaoyuan; Mi, Jie

    2016-01-01

    To investigate the joint effect of birth weight and each of obesity measures (body mass index (BMI) and waist circumference (WC)) on abnormal glucose metabolism (including diabetes) at adulthood. Using the historical cohort study design and the convenience sampling method, 1 921 infants who were born in Beijing Union Medical College Hospital from June 1948 to December 1954 were selected to do the follow-up in 1995 and 2001 respectively. Through Beijing Household Registration and Management System, they were invited to participate in this study. A total of 972 subjects (627 were followed up in 1995 and 345 were followed up in 2001) with complete information on genders, age, birth weight, family history of diabetes, BMI, WC, fasting plasma glucose (FPG) and 2-hour plasma glucose (2 h PG) met the study inclusion criteria at the follow-up visits. In the data analysis, they were divided into low, normal, and high birth weight, respectively. The ANOVA and Chi-squared tests were used to compare the differences in their characteristics by birth weight group. In addition, multiple binary Logistic regression model was used to investigate the single effect of birth weight, BMI, and waist circumference on abnormal glucose metabolism at adulthood. Stratification analysis was used to investigate the joint effect of birth weight and each of obesity measures (BMI and WC) on abnormal glucose metabolism. There were 972 subjects (males: 50.7%, mean age: (46.0±2.2) years) included in the final data analysis. The 2 h PG in low birth weight group was (7.6±3.2) mmol/L , which was higher than that in normal birth weight group (6.9±2.1) mmol/L and high birth weight group (6.4±1.3) mmol/L (F=3.88, P=0.021). After adjustment for genders, age, body length, gestation age, family history of diabetes, physical activity, smoking and alcohol consumption, and duration of follow-up, subjects with overweight and obesity at adulthood had 2.73 (95% confidence interval (CI) =2.06- 3.62) times risk

  2. Measurement of temporal asymmetries of glucose consumption using linear profiles: reproducibility and comparison with visual analysis

    International Nuclear Information System (INIS)

    Matheja, P.; Kuwert, T.; Schaefers, M.; Schaefers, K.; Schober, O.; Diehl, B.; Stodieck, S.R.G.; Ringelstein, E.B.; Schuierer, G.

    1998-01-01

    The aim of our study was to test the reproducibility of this method and to compare its diagnostic performance to that of visual analysis in patients with complex partial seizures (CPS). Regional cerebral glucose consumption (rCMRGLc) was measured interictally in 25 CPS patients and 10 controls using F-18-deoxyglucose and the positron emission tomography (PET) camera ECAT EXACT 47. The PET scans were visually analyzed for the occurrence of unilateral temporal hypometabolism. Furthermore, rCMRGLc was quantified on six contiguous coronal planes by manually tracing maximal values of temporal glucose consumption, thus creating line profiles of temporal glucose consumption for each side. Indices of asymmetry (ASY) were then calculated from these line profiles in four temporal regions and compared to the corresponding 95% confidence intervals of the control data. All analyses were performed by two observers independently from each other and without knowledge of the clinical findings. The agreement between the two observers with regard to focus lateralization was 96% on visual analysis and 100% on quantitative analysis. There was an excellent agreement with regard to focus lateralization between visual and quantitative evaluation. (orig.) [de

  3. Investigation of (/sup 18/F)2-fluoro-2-deoxyglucose for the measure of myocardial glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.; Kuhl, D.E.

    1978-12-01

    Fluorine-18-labeled 2-deoxyglucose (FDG) was studied as a glucose analog for the measure of myocardial glucose metabolism. Myocardial uptake and retention, blood clearance, species dependence (dog, monkey, man), and effect of diet on uptake were investigated. Normal myocardial uptake of FDG was 3 to 4% of injected dose in dog and monkey, and 1 to 4% in man, compared with brain uptakes of 1.5 to 3% in dog, 5 to 6% in monkey, and 4 to 8% in man. The myocardial metabolic rate (MR) for glucose in the nonfasting (glycolytic) state was 2.8 times that in the fasting (ketogenic) state. Human subjects showed higher myocardial uptake after a normal meal than after a meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t/sub 1/2/ of 0.2 to 0.3 min, followed by a t/sub 1/2/ of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had half-times of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. With the ECAT positron tomograph, high image-contrast ratios were found between heart and blood (dog 3.5/1, man 14/1), heart and lung (dog 9/1, man 20/1), and heart and liver (dog 15/1, man 10/1). The FDG was taken up rapidly by the myocardium without any significant tissue clearance over a 4-hr period. The FDG exhibited excellent imaging properties. Average counting rates of 12K, 20K, and 40K c/min-mCi injected are obtained in human subjects with high, medium, and low resolutions of the ECAT tomograph. Determination of glucose and FFA MR in vivo with EACT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man.

  4. Investigation of [18F]2-fluoro-2-deoxyglucose for the measure of myocardial glucose metabolism

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.; Kuhl, D.E.

    1978-01-01

    Fluorine-18-labeled 2-deoxyglucose (FDG) was studied as a glucose analog for the measure of myocardial glucose metabolism. Myocardial uptake and retention, blood clearance, species dependence (dog, monkey, man), and effect of diet on uptake were investigated. Normal myocardial uptake of FDG was 3 to 4% of injected dose in dog and monkey, and 1 to 4% in man, compared with brain uptakes of 1.5 to 3% in dog, 5 to 6% in monkey, and 4 to 8% in man. The myocardial metabolic rate (MR) for glucose in the nonfasting (glycolytic) state was 2.8 times that in the fasting (ketogenic) state. Human subjects showed higher myocardial uptake after a normal meal than after a meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t/sub 1/2/ of 0.2 to 0.3 min, followed by a t/sub 1/2/ of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had half-times of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. With the ECAT positron tomograph, high image-contrast ratios were found between heart and blood (dog 3.5/1, man 14/1), heart and lung (dog 9/1, man 20/1), and heart and liver (dog 15/1, man 10/1). The FDG was taken up rapidly by the myocardium without any significant tissue clearance over a 4-hr period. The FDG exhibited excellent imaging properties. Average counting rates of 12K, 20K, and 40K c/min-mCi injected are obtained in human subjects with high, medium, and low resolutions of the ECAT tomograph. Determination of glucose and FFA MR in vivo with EACT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man

  5. Associations of Body Composition Measurements with Serum Lipid, Glucose and Insulin Profile: A Chinese Twin Study

    Science.gov (United States)

    Liao, Chunxiao; Gao, Wenjing; Cao, Weihua; Lv, Jun; Yu, Canqing; Wang, Shengfeng; Zhou, Bin; Pang, Zengchang; Cong, Liming; Wang, Hua; Wu, Xianping; Li, Liming

    2015-01-01

    Objectives To quantitate and compare the associations of various body composition measurements with serum metabolites and to what degree genetic or environmental factors affect obesity-metabolite relation. Methods Body mass index (BMI), waist circumference (WC), lean body mass (LBM), percent body fat (PBF), fasting serum high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), triglycerides (TG), total cholesterol (TC), glucose, insulin and lifestyle factors were assessed in 903 twins from Chinese National Twin Registry (CNTR). Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated from fasting serum glucose and insulin. Linear regression models and bivariate structural equation models were used to examine the relation of various body composition measurements with serum metabolite levels and genetic/environmental influences on these associations, respectively. Results At individual level, adiposity measurements (BMI, WC and PBF) showed significant associations with serum metabolite concentrations in both sexes and the associations still existed in male twins when using within-MZ twin pair comparison analyses. Associations of BMI with TG, insulin and HOMA-IR were significantly stronger in male twins compared to female twins (BMI-by-sex interaction p = 0.043, 0.020 and 0.019, respectively). Comparison of various adiposity measurements with levels of serum metabolites revealed that WC explained the largest fraction of variance in serum LDL-C, TG, TC and glucose concentrations while BMI performed best in explaining variance in serum HDL-C, insulin and HOMA-IR levels. Of these phenotypic correlations, 64–81% were attributed to genetic factors, whereas 19–36% were attributed to unique environmental factors. Conclusions We observed different associations between adiposity and serum metabolite profile and demonstrated that WC and BMI explained the largest fraction of variance in serum lipid profile and insulin

  6. Hydrogen peroxide and glucose concentration measurement using optical fiber grating sensors with corrodible plasmonic nanocoatings.

    Science.gov (United States)

    Zhang, Xuejun; Wu, Ze; Liu, Fu; Fu, Qiangqiang; Chen, Xiaoyong; Xu, Jian; Zhang, Zhaochuan; Huang, Yunyun; Tang, Yong; Guo, Tuan; Albert, Jacques

    2018-04-01

    We propose and demonstrate hydrogen peroxide (H 2 O 2 ) and glucose concentration measurements using a plasmonic optical fiber sensor. The sensor utilizes a tilted fiber Bragg grating (TFBG) written in standard single mode communication fiber. The fiber is over coated with an nm-scale film of silver that supports surface plasmon resonances (SPRs). Such a tilted grating SPR structure provides a high density of narrow spectral resonances (Q-factor about 10 5 ) that overlap with the broader absorption band of the surface plasmon waves in the silver film, thereby providing an accurate tool to measure small shifts of the plasmon resonance frequencies. The H 2 O 2 to be detected acts as an oxidant to etch the silver film, which has the effect of gradually decreasing the SPR attenuation. The etching rate of the silver film shows a clear relationship with the H 2 O 2 concentration so that monitoring the progressively increasing attenuation of a selected surface plasmon resonance over a few minutes enables us to measure the H 2 O 2 concentration with a limit of detection of 0.2 μM. Furthermore, the proposed method can be applied to the determination of glucose in human serum for a concentration range from 0 to 12 mM (within the physiological range of 3-8 mM) by monitoring the H 2 O 2 produced by an enzymatic oxidation process. The sensor does not require accurate temperature control because of the inherent temperature insensitivity of TFBG devices referenced to the core mode resonance. A gold mirror coated on the fiber allows the sensor to work in reflection, which will facilitate the integration of the sensor with a hypodermic needle for in vitro measurements. The present study shows that Ag-coated TFBG-SPR can be applied as a promising type of sensing probe for optical detection of H 2 O 2 and glucose detection in human serum.

  7. Hydrogen peroxide and glucose concentration measurement using optical fiber grating sensors with corrodible plasmonic nanocoatings

    Science.gov (United States)

    Zhang, Xuejun; Wu, Ze; Liu, Fu; Fu, Qiangqiang; Chen, Xiaoyong; Xu, Jian; Zhang, Zhaochuan; Huang, Yunyun; Tang, Yong; Guo, Tuan; Albert, Jacques

    2018-01-01

    We propose and demonstrate hydrogen peroxide (H2O2) and glucose concentration measurements using a plasmonic optical fiber sensor. The sensor utilizes a tilted fiber Bragg grating (TFBG) written in standard single mode communication fiber. The fiber is over coated with an nm-scale film of silver that supports surface plasmon resonances (SPRs). Such a tilted grating SPR structure provides a high density of narrow spectral resonances (Q-factor about 105) that overlap with the broader absorption band of the surface plasmon waves in the silver film, thereby providing an accurate tool to measure small shifts of the plasmon resonance frequencies. The H2O2 to be detected acts as an oxidant to etch the silver film, which has the effect of gradually decreasing the SPR attenuation. The etching rate of the silver film shows a clear relationship with the H2O2 concentration so that monitoring the progressively increasing attenuation of a selected surface plasmon resonance over a few minutes enables us to measure the H2O2 concentration with a limit of detection of 0.2 μM. Furthermore, the proposed method can be applied to the determination of glucose in human serum for a concentration range from 0 to 12 mM (within the physiological range of 3-8 mM) by monitoring the H2O2 produced by an enzymatic oxidation process. The sensor does not require accurate temperature control because of the inherent temperature insensitivity of TFBG devices referenced to the core mode resonance. A gold mirror coated on the fiber allows the sensor to work in reflection, which will facilitate the integration of the sensor with a hypodermic needle for in vitro measurements. The present study shows that Ag-coated TFBG-SPR can be applied as a promising type of sensing probe for optical detection of H2O2 and glucose detection in human serum. PMID:29675315

  8. The effect of Sc additions on the microstructure and age hardening behaviour of as cast Al–Sc alloys

    International Nuclear Information System (INIS)

    Costa, S.; Puga, H.; Barbosa, J.; Pinto, A.M.P.

    2012-01-01

    Highlights: ► The Sc effect on the microstructure and ageing behaviour of Al–Sc alloys is studied. ► Cast into copper mould allows the elimination of solution heat treatment. ► Directly aged as cast alloys exhibits higher hardness and precipitation kinetics. ► Sc addition and optimised ageing result in an increase in Al–Sc mechanical properties. -- Abstract: The grain refinement effect and the ageing behaviour of Al–0.5 wt.% Sc, Al–0.7 wt.% Sc, and Al–1 wt.% Sc alloys are studied on the basis of optic microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD) observations and hardness measurements. In Al–Sc alloys the higher grain refinement is observed for Sc contents greater than 0.5 wt.% accompanied by a notorious morphology modification, from coarse columnar grains to a fine perfect equiaxed structure. The as cast structures are characterised by a rich supersaturated solid solution in Sc, that promotes a great age hardening response at 250 °C and 300 °C. The age hardening curves also demonstrate a low overageing kinetics for all the alloys. Although the higher Sc content in solid solution for the alloys with 0.7 and 1 wt.% Sc, the age hardening response of all the Al–Sc alloys remains similar. The direct age hardening response of the as cast Al–0.5 wt.% Sc is shown to be greater than the solutionised and age hardened alloy.

  9. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.

  10. Glucose-nucleobase pairs within DNA: impact of hydrophobicity, alternative linking unit and DNA polymerase nucleotide insertion studies† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7sc04850e

    Science.gov (United States)

    Vengut-Climent, Empar; Peñalver, Pablo; Lucas, Ricardo; Gómez-Pinto, Irene; Aviñó, Anna; Muro-Pastor, Alicia M.; Galbis, Elsa; de Paz, M. Violante; Fonseca Guerra, Célia; Bickelhaupt, F. Matthias; Eritja, Ramón; González, Carlos

    2018-01-01

    Recently, we studied glucose-nucleobase pairs, a binding motif found in aminoglycoside–RNA recognition. DNA duplexes with glucose as a nucleobase were able to hybridize and were selective for purines. They were less stable than natural DNA but still fit well on regular B-DNA. These results opened up the possible use of glucose as a non-aromatic DNA base mimic. Here, we have studied the incorporation and thermal stability of glucose with different types of anchoring units and alternative apolar sugar-nucleobase pairs. When we explored butanetriol instead of glycerol as a wider anchoring unit, we did not gain duplex thermal stability. This result confirmed the necessity of a more conformationally restricted linker to increase the overall duplex stability. Permethylated glucose-nucleobase pairs showed similar stability to glucoside-nucleobase pairs but no selectivity for a specific nucleobase, possibly due to the absence of hydrogen bonds between them. The three-dimensional structure of the duplex solved by NMR located both, the hydrophobic permethylated glucose and the nucleobase, inside the DNA helix as in the case of glucose-nucleobase pairs. Quantum chemical calculations on glucose-nucleobase pairs indicate that the attachment of the sugar to the DNA skeleton through the OH1 or OH4 positions yields the highest binding energies. Moreover, glucose was very selective for guanine when attached through OH1 or OH4 to the DNA. Finally, we examined DNA polymerase insertion of nucleotides in front of the saccharide unit. KF– polymerase from E. coli inserted A and G opposite glc and 6dglc with low efficiency but notable selectivity. It is even capable of extending the new pair although its efficiency depended on the DNA sequence. In contrast, Bst 2.0, SIII and BIOTAQ™ DNA polymerases seem to display a loop-out mechanism possibly due to the flexible glycerol linker used instead of deoxyribose. PMID:29780486

  11. Chaos based blood glucose noninvasive measurement: new concept and custom study

    Directory of Open Access Journals (Sweden)

    Cui Li

    2017-01-01

    Full Text Available Background. Non invasive monitoring of Blood Glucose (BG has been a challenge calling for new accurate and fast measurement methods. Objective. To propose new concept of chaos based BG non invasive test aiming at personal customization requirements. Methods. First to build the compact RC model of tissue BG through impedance precision measuring Kit, then to simulate and soft-test BG by Boolean chaotic Codec circuits in soft tool Multisim 13.0, The third to capture the chaotic decoding outputs with the Kit plus PC in calculated signatures of resistor and phase of the tested impedance at the subjects’ left wrist in synchronous test by Bayer BG meter. Results. All in controlled trials of Bayer BG meter, the chaotic BG modelling had gained three new compared formulae in merits of errors less than 1mmol/L and latency less than 1minute. Conclusion. During further verification of this chaotic test paradigm, the opened logic route of above methods will boost measurement experts’ confidence in overcoming future problems of blood glucose monitoring in vivo.

  12. Regional cerebral glucose consumption measured by positron emission tomography in patients with Wilson's disease

    International Nuclear Information System (INIS)

    Kuwert, T.; Scholz, D.; Milz, M.; Herzog, H.; Feinendegen, L.E.; Hefter, H.; Weiss, P.; Arendt, G.; Loken, M.; Minnesota Univ., Minneapolis, MN; Hennerici, M.

    1992-01-01

    Using positron emission tomography (PET), the regional cerebral metabolic rate of glucose consumption (rCMRGlc) was measured in 14 patients with Wilson's disease (WD) and 23 normal subjects. In WD patients, cerebellar, striatal and - to a lesser extent - cortical and thalamic rCMRGlc were significantly decreased compared with controls. Striatal rCMRGlc was significantly reduced in those 4 patients who had recently started decoppering therapy as compared with striatal rCMRGlc measured in those 10 patients with longer duration of medication. Caudate rCMRGlc correlated significantly with various signs of extrapyramidal dysfunction. Cerebellar, thalamic and cortical rCMRGlc correlated significantly with the severity of pyramidal signs. These data indicate that the PET measurement of rCMRGlc may be a useful tool to evaluate cerebral involvement in WD and to monitor the response to treatment. (orig.)

  13. Determination of Sc and Th in ScI3-NaI-ThI4 sample

    International Nuclear Information System (INIS)

    Yuan Hui; Yang Zhihong

    1999-01-01

    Determination of Sc and Th in ScI 3 -NaI-ThI 4 sample is studied by X-ray fluorescence and complexometry. The effect of working condition of Sc on X-ray fluorescence spectrometer and different sample-making method on the determination of Sc and Th are studied experimentally. The X-ray fluorescence analysis of determination of Sc and Th is developed by polyester film sample-making technique, the measuring precision of Sc and Th is better than 4%. The effect of acidity and temperature on the determining end point of titration is obvious. The results of different complexometric methods are compared. The precision of Sc and Th is less than 2% by comlexometry, it is fit for the routine analysis of ScI 3 -NaI-ThI 4 sample

  14. Accuracy of bedside glucose measurement from three glucometers in critically ill patients.

    NARCIS (Netherlands)

    Hoedemaekers, C.W.E.; Klein Gunnewiek, J.M.T.; Prinsen, M.A.; Willems, J.L.; Hoeven, J.G. van der

    2008-01-01

    OBJECTIVE: Implementation of strict glucose control in most intensive care units has resulted in increased use of point-of-care glucose devices in the intensive care unit. The aim of this study was to determine the reliability of point-of-care testing glucose meters among critically ill patients

  15. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  16. Development of a scale to measure adherence to self-monitoring of blood glucose with latent variable measurement.

    Science.gov (United States)

    Wagner, J A; Schnoll, R A; Gipson, M T

    1998-07-01

    Adherence to self-monitoring of blood glucose (SMBG) is problematic for many people with diabetes. Self-reports of adherence have been found to be unreliable, and existing paper-and-pencil measures have limitations. This study developed a brief measure of SMBG adherence with good psychometric properties and a useful factor structure that can be used in research and in practice. A total of 216 adults with diabetes responded to 30 items rated on a 9-point Likert scale that asked about blood monitoring habits. In part I of the study, items were evaluated and retained based on their psychometric properties. The sample was divided into exploratory and confirmatory halves. Using the exploratory half, items with acceptable psychometric properties were subjected to a principal components analysis. In part II of the study, structural equation modeling was used to confirm the component solution with the entire sample. Structural modeling was also used to test the relationship between these components. It was hypothesized that the scale would produce four correlated factors. Principal components analysis suggested a two-component solution, and confirmatory factor analysis confirmed this solution. The first factor measures the degree to which patients rely on others to help them test and thus was named "social influence." The second component measures the degree to which patients use physical symptoms of blood glucose levels to help them test and thus was named "physical influence." Results of the structural model show that the components are correlated and make up the higher-order latent variable adherence. The resulting 15-item scale provides a short, reliable way to assess patient adherence to SMBG. Despite the existence of several aspects of adherence, this study indicates that the construct consists of only two components. This scale is an improvement on previous measures of adherence because of its good psychometric properties, its interpretable factor structure, and its

  17. 'I try not to bother the residents too much' - the use of capillary blood glucose measurements in nursing homes.

    Science.gov (United States)

    Andreassen, Lillan Mo; Granas, Anne Gerd; Sølvik, Una Ørvim; Kjome, Reidun Lisbet Skeide

    2016-01-01

    Capillary blood glucose measurements are regularly used for nursing home residents with diabetes. The usefulness of these measurements relies on clear indications for use, correct measurement techniques, proper documentation and clinical use of the resulting blood glucose values. The use of a regular, invasive procedure may also entail additional challenges in a population of older, multimorbid patients who often suffer from cognitive impairment or dementia. The aim of this study was to explore the perspectives of physicians, registered nurses and auxiliary nurses on the use, usefulness and potential challenges of using capillary blood glucose measurements in nursing homes, and the procedures for doing so. This was a qualitative study that used three profession-specific focus group interviews. Interviews were transcribed in modified verbatim form and analysed in accordance with Malterud's principles of systematic text condensation. Five physicians, four registered nurses and three auxiliary nurses participated in the focus groups. All professional groups regarded capillary blood glucose measurements as a necessity in the management of diabetes, the physicians to ensure that the treatment is appropriate, and the nurses to be certain and assured about their caring decisions. Strict glycaemic control and excessive measurements were avoided in order to promote the well-being and safety of the residents. Sufficient knowledge of diabetes symptoms, equivalent practices for glucose measurement, and unambiguous documentation and communication of results were determined to be most helpful. However, all professional groups seldom involved the residents in managing their own measurements and stated that guidelines and training had been inconsistent or lacking. Inadequate procedures and training in diabetes care may compromise the rationale for capillary blood glucose measurements in nursing homes, and hence the residents' safety. These concerns should be addressed together

  18. DiSC-OPAL

    DEFF Research Database (Denmark)

    Kemal, Mohammed Seifu; Pedersen, Rasmus; Iov, Florin

    2017-01-01

    of such systems. The simulation tool should be able to model Electrical Grid and flexible assets with different time scales and resolution levels fulfilling specific functionalities. In this paper DiSC-OPAL, an OPAL-RT compatible toolbox library for modelling of assets is presented. The library is suitable...

  19. SC tuning fork

    CERN Document Server

    The tuning fork used to modulate the radiofrequency system of the synchro cyclotron (SC) from 1957 to 1973. This piece is an unused spare part. The SC was the 1st accelerator built at CERN. It operated from August 1957 until it was closed down at the end of 1990. In the SC the magnetic field did not change with time, and the particles were accelerated in successive pulses by a radiofrequency voltage of some 20kV which varied in frequency as they spiraled outwards towards the extraction radius. The frequency varied from 30MHz to about 17Mz in each pulse. The tuning fork vibrated at 55MHz in vacuum in an enclosure which formed a variable capacitor in the tuning circuit of the RF system, allowing the RF to vary over the appropriate range to accelerate protons from the centre of the macine up to 600Mev at extraction radius. In operation the tips of the tuning fork blade had an amplitude of movement of over 1 cm. The SC accelerator underwent extensive improvements from 1973 to 1975, including the installation of a...

  20. Selective conversion of plasma glucose into CO2 by Saccharomyces cerevisiae for the measurement of C-13 abundance by isotope ratio mass spectrometry : proof of principle

    NARCIS (Netherlands)

    Rembacz, Krzysztof P.; Faber, Klaas Nico; Stellaard, Frans

    2007-01-01

    To study carbohydrate digestion and glucose absorption, time-dependent C-13 enrichment in plasma glucose is measured after oral administration of naturally occurring C-13-enriched carbohydrates. The isotope enrichment of the administered carbohydrate is low (APE <0.1%) and plasma C-13 glucose

  1. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

    Science.gov (United States)

    Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin

    2017-06-01

    In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady

  2. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Weerwind, P.W.; Teerenstra, S.; Brouwer, René

    2006-01-01

    BACKGROUND: Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the

  3. Relation of measured brain glucose utilisation and cerebral atrophy in man.

    Science.gov (United States)

    Schlageter, N L; Horwitz, B; Creasey, H; Carson, R; Duara, R; Berg, G W; Rapoport, S I

    1987-06-01

    The effect of cerebral atrophy on measured cerebral metabolic rates for glucose (CMRglc), as determined with positron emission tomography (PET), was examined in 49 healthy males aged 21-83 years. Global CMRglc and regional CMRglc for 34 grey matter regions parallel to and from 30 to 80 mm above the inferior orbital meatal (IOM) line were measured under resting conditions, using [18F]-fluorodeoxyglucose and an ECAT II positron emission tomograph. Using a GE 8800 CT/T scanner, slices parallel to and from 30 to 80 mm above the IOM line were analysed for CSF volume. Cerebral atrophy, indicated by increased CSF volume, was correlated significantly with global CMRglc, but accounted for no more than 13% of the variance in the CMRglc measurements. Methods for correcting for inter-subject variation in CSF volume were proposed. Global values for CMRglc, uncorrected or corrected for CSF volume, were found to be age invariant. These findings indicate that (a) cerebral atrophy has a small, but statistically significant effect on CMRglc as measured with PET; (b) CMRglc is age invariant in healthy males.

  4. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  5. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  6. Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes.

    Science.gov (United States)

    Law, Graham R; Gilthorpe, Mark S; Secher, Anna L; Temple, Rosemary; Bilous, Rudolf; Mathiesen, Elisabeth R; Murphy, Helen R; Scott, Eleanor M

    2017-04-01

    This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA 1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA 1c measurements are applicable to pregnant women with diabetes. CGM data from 117 pregnant women (89 women with type 1 diabetes; 28 women with type 2 diabetes) were analysed. Average glucose levels were calculated from 5-7 day CGM profiles (mean 1275 glucose values per profile) and paired with a corresponding (±1 week) HbA 1c measure. In total, 688 average glucose-HbA 1c pairs were obtained across pregnancy (mean six pairs per participant). Average glucose level was used as the dependent variable in a regression model. Covariates were gestational week, study centre and HbA 1c . There was a strong association between HbA 1c and average glucose values in pregnancy (coefficient 0.67 [95% CI 0.57, 0.78]), i.e. a 1% (11 mmol/mol) difference in HbA 1c corresponded to a 0.67 mmol/l difference in average glucose. The random effects model that included gestational week as a curvilinear (quadratic) covariate fitted best, allowing calculation of a pregnancy-specific eAG (PeAG). This showed that an HbA 1c of 8.0% (64 mmol/mol) gave a PeAG of 7.4-7.7 mmol/l (depending on gestational week), compared with a standard eAG of 10.2 mmol/l. The PeAG associated with maintaining an HbA 1c level of 6.0% (42 mmol/mol) during pregnancy was between 6.4 and 6.7 mmol/l, depending on gestational week. The HbA 1c -average glucose relationship is altered by pregnancy. Routinely generated standard eAG values do not account for this difference between pregnant and non-pregnant individuals and, thus, should not be used during pregnancy. Instead, the PeAG values deduced in the current study are recommended for antenatal clinical care.

  7. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Blood flow rates of AV fistula can be affected by osmotic and oncotic pressures of blood and arterial blood pressures. Sodium, glucose, hemoglobin, and albumin are significant effectors, created osmotic and oncotic pressures [Table 3]. Blood levels of hemoglobin. (Hb), albumin, sodium (Na), and glucose ...

  8. A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes.

    Science.gov (United States)

    Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Maekawa, Yasunori; Nakajima, Hiromu

    2012-06-01

    Recent studies have highlighted the importance of managing postprandial hyperglycemia, but adequate monitoring of postprandial glucose remains difficult because of wide variations in levels. We have therefore developed a minimally invasive system to monitor postprandial glucose area under the curve (AUC). This system involves no blood sampling and uses interstitial fluid glucose (IG) AUC (IG-AUC) as a surrogate marker of postprandial glucose. This study aimed to evaluate the usefulness of this system by comparing data with the findings of oral glucose tolerance tests (OGTTs) in subjects with and without diabetes. The glucose AUC monitoring system was validated by OGTTs in 37 subjects with and 10 subjects without diabetes. A plastic microneedle array was stamped on the forearm to extract IG. A hydrogel patch was then placed on the pretreated area to accumulate IG. Glucose and sodium ion concentrations in the hydrogel were measured to calculate IG-AUC at 2-h postload glucose. Plasma glucose (PG) levels were measured every 30 min to calculate reference PG-AUC. IG-AUC correlated strongly with reference PG-AUC (r=0.93) over a wide range. The level of correlation between IG-AUC and maximum PG level was also high (r=0.86). The painless nature of the technique was confirmed by the response of patients to questionnaires. The glucose AUC monitoring system using IG provided good estimates of reference PG-AUC and maximum PG level during OGTTs in subjects with and without diabetes. This system provides easy-to-use monitoring of glucose AUC, which is a good indicator of postprandial glucose.

  9. The relationship between HbA(1c) and fasting plasma glucose in patients with increased plasma liver enzyme measurements

    DEFF Research Database (Denmark)

    Christiansen, R; Rasmussen, L Melholt; Nybo, H

    2012-01-01

    levels of increased liver enzyme concentrations. Methods:  Data from 10 065 patients with simultaneous measurement of HbA(1c) , venous fasting plasma glucose, alanine aminotransferase and γ-glutamyl transferase were extracted from our laboratory database. Correlations were investigated in four patient...

  10. Age and sex differences in cerebral glucose consumption measured by pet using [18-F] fluorodeoxyglucose (FDG)

    International Nuclear Information System (INIS)

    Duara, R.; Barker, W.; Chang, J.; Apicella, A.; Finn, R.; Gilson, A.

    1985-01-01

    Resting cerebral glucose metabolic rates (CMRglc) were measured in 23 subjects by PET using FDG. Subjects were divided into several groups (mean age +- S.D.) 5 young males (YM) (27 +- 6); 6 young females (YF)(33 +9); 5 elderly males (EM)(73 +- 5); 7 elderly females (EF)(69 +- 7). Additionally, from these groups 4 YM, 3YF, 5EM and 4EF were studied again within 6 weeks under identical conditions. CMRglc in the YF group again was significantly hider than YM (p 0.05). No obvious relationships of CMRglc to the phase of the menstrual cycle was found in this small group. There was a trend (p=0.06) toward a higher CMRglc in YF than EF. These results support the findings of higher CBF in YF versus YM. The differences between the results of Kuhl et al (J. Cereb. and a reduction of CMRglc with age was found in a mixed group of males and females (58and female), and where no age effect was found the males, are also resolved by these findings. The authors suggest that the apparent age effect, in females in this study, is principally a hormonal one

  11. Shikonin increases glucose uptake in skeletal muscle cells and improves plasma glucose levels in diabetic Goto-Kakizaki rats.

    Directory of Open Access Journals (Sweden)

    Anette I Öberg

    Full Text Available BACKGROUND: There is considerable interest in identifying compounds that can improve glucose homeostasis. Skeletal muscle, due to its large mass, is the principal organ for glucose disposal in the body and we have investigated here if shikonin, a naphthoquinone derived from the Chinese plant Lithospermum erythrorhizon, increases glucose uptake in skeletal muscle cells. METHODOLOGY/PRINCIPAL FINDINGS: Shikonin increases glucose uptake in L6 skeletal muscle myotubes, but does not phosphorylate Akt, indicating that in skeletal muscle cells its effect is medaited via a pathway distinct from that used for insulin-stimulated uptake. Furthermore we find no evidence for the involvement of AMP-activated protein kinase in shikonin induced glucose uptake. Shikonin increases the intracellular levels of calcium in these cells and this increase is necessary for shikonin-mediated glucose uptake. Furthermore, we found that shikonin stimulated the translocation of GLUT4 from intracellular vesicles to the cell surface in L6 myoblasts. The beneficial effect of shikonin on glucose uptake was investigated in vivo by measuring plasma glucose levels and insulin sensitivity in spontaneously diabetic Goto-Kakizaki rats. Treatment with shikonin (10 mg/kg intraperitoneally once daily for 4 days significantly decreased plasma glucose levels. In an insulin sensitivity test (s.c. injection of 0.5 U/kg insulin, plasma glucose levels were significantly lower in the shikonin-treated rats. In conclusion, shikonin increases glucose uptake in muscle cells via an insulin-independent pathway dependent on calcium. CONCLUSIONS/SIGNIFICANCE: Shikonin increases glucose uptake in skeletal muscle cells via an insulin-independent pathway dependent on calcium. The beneficial effects of shikonin on glucose metabolism, both in vitro and in vivo, show that the compound possesses properties that make it of considerable interest for developing novel treatment of type 2 diabetes.

  12. Effects of glucose ingestion on autonomic and cardiovascular measures during rest and mental challenge

    NARCIS (Netherlands)

    Synowski, S.J.; Kop, W.J.; Warwick, Z.S.; Waldstein, S.R.

    2013-01-01

    Background High levels of dietary sugar consumption may result in dysregulated glucose metabolism and lead to elevated cardiovascular disease risk via autonomic nervous system and cardiovascular dysfunction. Altered cardiovascular function can be examined using perturbation tasks such as mental

  13. Measurement of regional cerebral glucose utilization in man by positron emission tomography

    International Nuclear Information System (INIS)

    Baron, J.C.

    1986-05-01

    The various methods available for the study of regional cerebral glucose consumption in man by positron emission tomography are described and their applications, limitations and principal physiopathological results are presented [fr

  14. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  15. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  16. Simultaneous measurement of glucose blood–brain transport constants and metabolic rate in rat brain using in-vivo 1H MRS

    Science.gov (United States)

    Du, Fei; Zhang, Yi; Zhu, Xiao-Hong; Chen, Wei

    2012-01-01

    Cerebral glucose consumption and glucose transport across the blood–brain barrier are crucial to brain function since glucose is the major energy fuel for supporting intense electrophysiological activity associated with neuronal firing and signaling. Therefore, the development of noninvasive methods to measure the cerebral metabolic rate of glucose (CMRglc) and glucose transport constants (KT: half-saturation constant; Tmax: maximum transport rate) are of importance for understanding glucose transport mechanism and neuroenergetics under various physiological and pathological conditions. In this study, a novel approach able to simultaneously measure CMRglc, KT, and Tmax via monitoring the dynamic glucose concentration changes in the brain tissue using in-vivo 1H magnetic resonance spectroscopy (MRS) and in plasma after a brief glucose infusion was proposed and tested using an animal model. The values of CMRglc, Tmax, and KT were determined to be 0.44±0.17 μmol/g per minute, 1.35±0.47 μmol/g per minute, and 13.4±6.8 mmol/L in the rat brain anesthetized with 2% isoflurane. The Monte-Carlo simulations suggest that the measurements of CMRglc and Tmax are more reliable than that of KT. The overall results indicate that the new approach is robust and reliable for in-vivo measurements of both brain glucose metabolic rate and transport constants, and has potential for human application. PMID:22714049

  17. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-05-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions.

  18. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    International Nuclear Information System (INIS)

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-01-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions

  19. Comparison of optical coherence tomography, the pulsed photoacoustic technique, and the time-of-flight technique in glucose measurements in vitro

    OpenAIRE

    Kinnunen, M. (Matti)

    2006-01-01

    Abstract The development of a non-invasive glucose monitoring technique is very important because it would tremendously diminish the need to puncture the skin when taking blood samples and help diabetic patients in controlling their blood glucose levels and in treating Diabetes Mellitus. The focus of this thesis is on measuring the effect of glucose on the light scattering properties of a tissue-simulating phantom and biological tissues in vitro. Optical coherence tomography (OCT), the pul...

  20. Academic Training - Pulsed SC Magnets

    CERN Multimedia

    Françoise Benz

    2006-01-01

    2005-2006 ACADEMIC TRAINING PROGRAMME LECTURE SERIES 2, 3, June 29, 30, 31 May, 1, 2 June 11:00-12:00 - Auditorium, bldg 500 Pulsed SC Magnets by M. Wilson Lecture 1. Introduction to Superconducting Materials Type 1,2 and high temperature superconductors; their critical temperature, field & current density. Persistent screening currents and the critical state model. Lecture 2. Magnetization and AC Loss How screening currents cause irreversible magnetization and hysteresis loops. Field errors caused by screening currents. Flux jumping. The general formulation of ac loss in terms of magnetization. AC losses caused by screening currents. Lecture 3. Twisted Wires and Cables Filamentary composite wires and the losses caused by coupling currents between filaments, the need for twisting. Why we need cables and how the coupling currents in cables contribute more ac loss. Field errors caused by coupling currents. Lecture 4. AC Losses in Magnets, Cooling and Measurement Summary of all loss mech...

  1. Electrocatalytic glucose sensor

    Energy Technology Data Exchange (ETDEWEB)

    Gebhardt, U; Luft, G; Mund, K; Preidel, W; Richter, G J

    1983-01-01

    An artificial pancreas consists of an insulin depot, a dosage unit and a glucose sensor. The measurement of the actual glucose concentration in blood is still an unsolved problem. Two methods are described for an electrocatalytic glucose sensor. Under the interfering action of amino acids and urea in-vitro measurements show an error of between 10% and 20%.

  2. Blood glucose, lactate, pyruvate, glycerol, 3-hydroxybutyrate and acetoacetate measurements in man using a centrifugal analyser with a fluorimetric attachment.

    Science.gov (United States)

    Harrison, J; Hodson, A W; Skillen, A W; Stappenbeck, R; Agius, L; Alberti, K G

    1988-03-01

    Methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, 3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood, using the Cobas Bio centrifugal analyser fitted with a fluorimetric attachment. Intra-assay and inter-assay coefficients of variation ranged from 1.9 to 7.9% and from 1.0 to 7.2% respectively. Correlation coefficients ranged from 0.96 to 0.99 against established continuous-flow and manual spectrophotometric methods. All seven metabolites can be measured using a single perchloric acid extract of 20 microliter of blood. The versatility of the assays is such that as little as 100 pmol pyruvate, 3-hydroxybutyrate or as much as 15 nmol glucose can be measured in the same 20 microliter extract.

  3. Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

    Science.gov (United States)

    Tachibana, K; Okada, K; Kobayashi, R; Ishihara, Y

    2016-08-01

    We describe the possibility of high-sensitivity noninvasive blood glucose measurement based on photoacoustic spectroscopy (PAS). The demand for noninvasive blood glucose-level measurement has increased due to the explosive increase in diabetic patients. We have developed a noninvasive blood glucose-level measurement based on PAS. The conventional method uses a straight-type resonant cell. However, the cell volume is large, which results in a low detection sensitivity and difficult portability. In this paper, a small-sized Helmholtz-type resonant cell is proposed to improve detection sensitivity and portability by reducing the cell dead volume. First, the acoustic property of the small-sized Helmholtz-type resonant cell was evaluated by performing an experiment using a silicone rubber. As a result, the detection sensitivity of the small-sized Helmholtz-type resonant cell was approximately two times larger than that of the conventional straight-type resonant cell. In addition, the inside volume was approximately 30 times smaller. Second, the detection limits of glucose concentration were estimated by performing an experiment using glucose solutions. The experimental results showed that a glucose concentration of approximately 1% was detected by the small-sized Helmholtz-type resonant cell. Although these results on the sensitivity of blood glucose-level measurement are currently insufficient, they suggest that miniaturization of a resonance cell is effective in the application of noninvasive blood glucose-level measurement.

  4. In Silico Assessment of Literature Insulin Bolus Calculation Methods Accounting for Glucose Rate of Change.

    Science.gov (United States)

    Cappon, Giacomo; Marturano, Francesca; Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni

    2018-05-01

    The standard formula (SF) used in bolus calculators (BCs) determines meal insulin bolus using "static" measurement of blood glucose concentration (BG) obtained by self-monitoring of blood glucose (SMBG) fingerprick device. Some methods have been proposed to improve efficacy of SF using "dynamic" information provided by continuous glucose monitoring (CGM), and, in particular, glucose rate of change (ROC). This article compares, in silico and in an ideal framework limiting the exposition to possibly confounding factors (such as CGM noise), the performance of three popular techniques devised for such a scope, that is, the methods of Buckingham et al (BU), Scheiner (SC), and Pettus and Edelman (PE). Using the UVa/Padova Type 1 diabetes simulator we generated data of 100 virtual subjects in noise-free, single-meal scenarios having different preprandial BG and ROC values. Meal insulin bolus was computed using SF, BU, SC, and PE. Performance was assessed with the blood glucose risk index (BGRI) on the 9 hours after meal. On average, BU, SC, and PE improve BGRI compared to SF. When BG is rapidly decreasing, PE obtains the best performance. In the other ROC scenarios, none of the considered methods prevails in all the preprandial BG conditions tested. Our study showed that, at least in the considered ideal framework, none of the methods to correct SF according to ROC is globally better than the others. Critical analysis of the results also suggests that further investigations are needed to develop more effective formulas to account for ROC information in BCs.

  5. Detection of glutathione based on MnO2 nanosheet-gated mesoporous silica nanoparticles and target induced release of glucose measured with a portable glucose meter.

    Science.gov (United States)

    Tan, Qingqing; Zhang, Ruirui; Kong, Rongmei; Kong, Weisu; Zhao, Wenzhi; Qu, Fengli

    2017-12-08

    The authors describe a novel method for the determination of glutathione (GSH). Detection is based on target induced release of glucose from MnO 2 nanosheet-gated aminated mesoporous silica nanoparticles (MSNs). In detail, glucose is loaded into the pores of MSNs. Negatively charged MnO 2 nanosheets are assembled on the MSNs through electrostatic interactions. The nanosheets are reduced by GSH, and this results in the release of glucose which is quantified by using a commercial electrochemical glucose meter. GSH can be quantified by this method in the 100 nM to 10 μM concentration range, with a 34 nM limit of detection. Graphical abstract Glucose is loaded into the pores of mesoporous silica nanoparticles (MSNs). MnO 2 nanosheets are assembled on MSNs through electrostatic interactions. Glutathione (GSH) can reduce the nanosheets, and this results in the release of glucose which is quantified by using a commercial glucose meter.

  6. Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants.

    Science.gov (United States)

    Hwang, Joon Ho; Sohn, Yong-Hak; Chang, Seong-Sil; Kim, Seung Yeon

    2015-08-01

    We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ≤2,300 g or were ≤36 weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels≤60 mg/dL, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment , after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ≤60 mg/dL), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.

  7. Effects of temperature on the near-infrared spectroscopic measurement of glucose

    Science.gov (United States)

    Jung, Byungjo; McShane, Michael J.; Rastegar, Sohi; Cote, Gerard L.

    1998-05-01

    The noninvasive monitoring of sugars, and in particular, glucose using near-IR (NIR) spectroscopy would be useful for a number of applications including regulating the nutrients in cell culture medium, monitoring on-line processes in the food industry, and in vivo monitoring for control of glucose in DIabetic patients. The focus of this research was the investigation of the temperature effects across a 10.6 to 40.4 degrees C range on Fourier filtered and unfiltered single-beam as well as absorbance glucose and water NIR spectra. It is known that the positions of water absorption bands centered at 1.923 and 2.623 micrometers depend heavily on temperature effects while the glucose bands are temperature insensitive across this range. The water absorption bands were shown to shift to lower wavelengths while the distance between these bands increased with increasing temperatures. Partial least squares (PLS) calibration models were constructed at five separate temperatures, 15.7, 20.5, 25.5, 35.6, and 40.4 degrees C. When absorbance spectra were used with reference scans taken at the same temperature and PLS models were used, no significant difference in the standard error of prediction (SEP) was noted with temperature. Using PLS calibration with single-beam spectra at one temperature showed large SEPs at the other temperatures. The use of Fourier filtered single-beam spectra reduced the SEP but still showed an increase as large temperature differences were produced and the filtered single beam approach did not reduce the SEP to the level achieved with the absorbance spectra.

  8. Glucose pump test can be used to measure blood flow rate of native arteriovenous fistula in chronic hemodialysis.

    Science.gov (United States)

    Yavuz, Y C; Selcuk, N Y; Altıntepe, L; Güney, I; Yavuz, S

    2018-01-01

    In chronic hemodialysis patients, the low flow of vascular access may leads to inadequate dialysis, increased rate of hospitalization, morbidity, and mortality. It was found that surveillance should be performed for native arteriovenous (AV) should not be performed for AV graft in various studies. However, surveillance was done in graft AV fistulas in most studies. Doppler ultrasonography (US) was suggested for surveillance of AV fistulas by the last vascular access guideline of National Kidney Foundation Disease Outcomes Quality Initiative (NKF KDOQI). The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by pump and was measured at basal before the infusion and 11 s after the start of the infusion by glucometer. Doppler US was done by an expert radiologist. Used statistical tests were Mann-Whitney U test, Friedman test, regression analysis, and multiple regression analysis. Median values of blood flow rates measured by GPT (707 mL/min) and by Doppler US (700 mL/min) were not different (Z = 0.414, P = 0.678). Results of GPT and Doppler US measurements were positive correlate by regression analysis. The mean GPT value of diabetic patients (n = 39; 908 mL/min) was similar to that of nondiabetic patients (n = 54; 751 mL/min; Z = 1.31, P = 0.188). GPT values measured at three different dialysis session did not differ from each other that by Friedman test (F = 0.92, P = 0.39). This showed that GPT was stable and reliable. Glucose pump test can be used to measure blood flow rate of native AV fistula. GPT is an accurate and reliable test.

  9. TheClinical Research Tool: a high-performance microdialysis-based system for reliably measuring interstitial fluid glucose concentration.

    Science.gov (United States)

    Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido

    2009-05-01

    A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. In vitro characterization with buffered glucose solutions (c(glucose) = 0 - 26 x 10(-3) mol liter(-1)) over 120 h yielded a mean absolute relative error (MARE) of 2.9 +/- 0.9% and a recorded mean flow rate of 330 +/- 48 nl/min with periodic flow rate variation amounting to 24 +/- 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 +/- 59 nl/min and a periodic variation of 22 +/- 6% were recorded. Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 +/- 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. 2009 Diabetes Technology Society.

  10. Association between the extent of urinary albumin excretion and glycaemic variability indices measured by continuous glucose monitoring.

    Science.gov (United States)

    Jin, S-M; Kim, T-H; Oh, S; Baek, J; Joung, J Y; Park, S-M; Cho, Y Y; Sohn, S Y; Hur, K Y; Lee, M-S; Lee, M-K; Kim, J H

    2015-02-01

    The contribution of glycaemic variability to the microvascular complication of diabetes has not been established. We examined whether there is an independent association between indices of glycaemic variability in continuous glucose monitoring and extent of albuminuria. A total of 173 patients with Type 2 diabetes (without insulin therapy, n = 96; with insulin therapy, n = 77) who had unexplained large fluctuations in blood glucose values underwent three-day continuous glucose monitoring. We used a multinomial logistic regression model to determine whether the indices of glycaemic variability independently affected the odds of having a spot urine albumin/creatinine ratio of 30-299 mg/g and ≥ 300 mg/g. Higher standard deviation (P = 0.002), mean of daily differences (P = 0.023) and mean amplitude of glycaemic excursion (P = 0.043) significantly increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g. In multivariable analysis, only higher standard deviation, but not mean amplitude of glycaemic excursion and mean of daily differences, independently increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g (P = 0.025). Coefficient of variation (sd/mean) was not associated with the odds of having a urine albumin/creatinine ratio of 30-299 or ≥ 300 mg/g. The independent association between standard deviation and the extent of albuminuria was lost when the measures were normalized by mean glucose level. At least in terms of relative measures of glycaemic variability, we failed to demonstrate an independent association between glycaemic variability and albuminuria extent in patients with inadequately controlled Type 2 diabetes. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  11. The product of triglycerides and glucose, a simple measure of insulin sensitivity. Comparison with the euglycemic-hyperinsulinemic clamp.

    Science.gov (United States)

    Guerrero-Romero, Fernando; Simental-Mendía, Luis E; González-Ortiz, Manuel; Martínez-Abundis, Esperanza; Ramos-Zavala, María G; Hernández-González, Sandra O; Jacques-Camarena, Omar; Rodríguez-Morán, Martha

    2010-07-01

    To meet the worldwide challenge of emerging diabetes, accessible and inexpensive tests to identify insulin resistance are needed. To evaluate the sensitivity and specificity of the product of fasting, we compared the triglycerides and glucose (TyG) index, a simple measure of insulin resistance, with the euglycemic-hyperinsulinemic clamp test. We conducted a cross-sectional study of the general population and outpatients of the Internal Medicine Department at the Medical Unit of High Specialty of the Specialty Hospital at the West National Medical Center in Guadalajara, Mexico. Eleven nonobese healthy subjects, 34 obese normal glucose tolerance individuals, 22 subjects with prediabetes, and 32 diabetic patients participated in the study. We performed a euglycemic-hyperinsulinemic clamp test. Sensitivity and specificity of the TyG index [Ln(fasting triglycerides) (mg/dl) x fasting glucose (mg/dl)/2] were measured, as well as the area under the curve of the receiver operating characteristic scatter plot and the correlation between the TyG index and the total glucose metabolism (M) rates. Pearson's correlation coefficient between the TyG index and M rates was -0.681 (P index and M rates was similar between men (-0.740) and women (-0.730), nonobese (-0.705) and obese (-0.710), and nondiabetic (-0.670) and diabetic (-0.690) individuals. The best value of the TyG index for diagnosis of insulin resistance was 4.68, which showed the highest sensitivity (96.5%) and specificity (85.0%; area under the curve + 0.858). The TyG index has high sensitivity and specificity, suggesting that it could be useful for identification of subjects with decreased insulin sensitivity.

  12. Visceral adiposity is associated with altered myocardial glucose uptake measured by (18)FDG-PET in 346 subjects with normal glucose tolerance, prediabetes, and type 2 diabetes.

    Science.gov (United States)

    Kim, Gyuri; Jo, Kwanhyeong; Kim, Kwang Joon; Lee, Yong-ho; Han, Eugene; Yoon, Hye-jin; Wang, Hye Jin; Kang, Eun Seok; Yun, Mijin

    2015-11-04

    The heart requires constant sources of energy mostly from free fatty acids (FFA) and glucose. The alteration in myocardial substrate metabolism occurs in the heart of diabetic patients, but its specific association with other metabolic variables remains unclear. We aimed to evaluate glucose uptake in hearts of subjects with normal glucose tolerance (NGT), prediabetes, and type 2 diabetes mellitus (T2DM) using [(18)F]-fluorodeoxyglucose-positron emission tomography ((18)FDG-PET) in association with visceral and subcutaneous adiposity, and metabolic laboratory parameters. A total of 346 individuals (NGT, n = 76; prediabetes, n = 208; T2DM, n = 62) in a health promotion center of a tertiary hospital were enrolled. The fasting myocardial glucose uptake, and visceral and subcutaneous fat areas were evaluated using (18)FDG-PET and abdominal computed tomography, respectively. Myocardial glucose uptake was significantly decreased in subjects with T2DM compared to the NGT or prediabetes groups (p for trend = 0.001). Multivariate linear regression analyses revealed that visceral fat area (β = -0.22, p = 0.018), fasting FFA (β = -0.39, p < 0.001), and uric acid levels (β = -0.21, p = 0.007) were independent determinants of myocardial glucose uptake. Multiple logistic analyses demonstrated that decreased myocardial glucose uptake (OR 2.32; 95% CI 1.02-5.29, p = 0.045) and visceral fat area (OR 1.02, 95% CI 1.01-1.03, p = 0.018) were associated with T2DM. Our findings indicate visceral adiposity is strongly associated with the alteration of myocardial glucose uptake evaluated by (18)FDG-PET, and its association further relates to T2DM.

  13. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    International Nuclear Information System (INIS)

    Anazodo, Udunna; Kewin, Matthew; Finger, Elizabeth; Thiessen, Jonathan; Hadway, Jennifer; Butler, John; Pavlosky, William; Prato, Frank; Thompson, Terry; St Lawrence, Keith

    2015-01-01

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  14. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Anazodo, Udunna; Kewin, Matthew [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Finger, Elizabeth [Department of Clinical Neurological Sciences, Western University, London, Ontario (Canada); Thiessen, Jonathan; Hadway, Jennifer; Butler, John [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Pavlosky, William [Diagnostic Imaging, St Joseph' s Health Care, London, Ontario (Canada); Prato, Frank; Thompson, Terry; St Lawrence, Keith [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada)

    2015-05-18

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  15. In vivo cardiac glucose metabolism in the high-fat fed mouse: Comparison of euglycemic–hyperinsulinemic clamp derived measures of glucose uptake with a dynamic metabolomic flux profiling approach

    International Nuclear Information System (INIS)

    Kowalski, Greg M.; De Souza, David P.; Risis, Steve; Burch, Micah L.; Hamley, Steven; Kloehn, Joachim; Selathurai, Ahrathy; Lee-Young, Robert S.; Tull, Dedreia; O'Callaghan, Sean; McConville, Malcolm J.; Bruce, Clinton R.

    2015-01-01

    Rationale: Cardiac metabolism is thought to be altered in insulin resistance and type 2 diabetes (T2D). Our understanding of the regulation of cardiac substrate metabolism and insulin sensitivity has largely been derived from ex vivo preparations which are not subject to the same metabolic regulation as in the intact heart in vivo. Studies are therefore required to examine in vivo cardiac glucose metabolism under physiologically relevant conditions. Objective: To determine the temporal pattern of the development of cardiac insulin resistance and to compare with dynamic approaches to interrogate cardiac glucose and intermediary metabolism in vivo. Methods and results: Studies were conducted to determine the evolution of cardiac insulin resistance in C57Bl/6 mice fed a high-fat diet (HFD) for between 1 and 16 weeks. Dynamic in vivo cardiac glucose metabolism was determined following oral administration of [U- 13 C] glucose. Hearts were collected after 15 and 60 min and flux profiling was determined by measuring 13 C mass isotopomers in glycolytic and tricarboxylic acid (TCA) cycle intermediates. Cardiac insulin resistance, determined by euglycemic–hyperinsulinemic clamp, was evident after 3 weeks of HFD. Despite the presence of insulin resistance, in vivo cardiac glucose metabolism following oral glucose administration was not compromised in HFD mice. This contrasts our recent findings in skeletal muscle, where TCA cycle activity was reduced in mice fed a HFD. Similar to our report in muscle, glucose derived pyruvate entry into the TCA cycle in the heart was almost exclusively via pyruvate dehydrogenase, with pyruvate carboxylase mediated anaplerosis being negligible after oral glucose administration. Conclusions: Under experimental conditions which closely mimic the postprandial state, the insulin resistant mouse heart retains the ability to stimulate glucose metabolism. - Highlights: • Insulin clamp was used to determine the evolution of cardiac insulin

  16. In vivo cardiac glucose metabolism in the high-fat fed mouse: Comparison of euglycemic–hyperinsulinemic clamp derived measures of glucose uptake with a dynamic metabolomic flux profiling approach

    Energy Technology Data Exchange (ETDEWEB)

    Kowalski, Greg M., E-mail: greg.kowalski@deakin.edu.au [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia); De Souza, David P. [Metabolomics Australia, Department of Biochemistry and Molecular Biology, Bio21 Institute of Molecular Science and Biotechnology, University of Melbourne, Parkville, Victoria 3010 (Australia); Risis, Steve [Cellular and Molecular Metabolism Laboratory, Baker IDI Heart and Diabetes Institute, Melbourne, Victoria 3004 (Australia); Burch, Micah L. [Brigham and Women' s Hospital, Department of Medicine, Boston, MA (United States); Hamley, Steven [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia); Kloehn, Joachim [Metabolomics Australia, Department of Biochemistry and Molecular Biology, Bio21 Institute of Molecular Science and Biotechnology, University of Melbourne, Parkville, Victoria 3010 (Australia); Selathurai, Ahrathy [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia); Lee-Young, Robert S. [Cellular and Molecular Metabolism Laboratory, Baker IDI Heart and Diabetes Institute, Melbourne, Victoria 3004 (Australia); Tull, Dedreia; O' Callaghan, Sean; McConville, Malcolm J. [Metabolomics Australia, Department of Biochemistry and Molecular Biology, Bio21 Institute of Molecular Science and Biotechnology, University of Melbourne, Parkville, Victoria 3010 (Australia); Bruce, Clinton R. [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia)

    2015-08-07

    Rationale: Cardiac metabolism is thought to be altered in insulin resistance and type 2 diabetes (T2D). Our understanding of the regulation of cardiac substrate metabolism and insulin sensitivity has largely been derived from ex vivo preparations which are not subject to the same metabolic regulation as in the intact heart in vivo. Studies are therefore required to examine in vivo cardiac glucose metabolism under physiologically relevant conditions. Objective: To determine the temporal pattern of the development of cardiac insulin resistance and to compare with dynamic approaches to interrogate cardiac glucose and intermediary metabolism in vivo. Methods and results: Studies were conducted to determine the evolution of cardiac insulin resistance in C57Bl/6 mice fed a high-fat diet (HFD) for between 1 and 16 weeks. Dynamic in vivo cardiac glucose metabolism was determined following oral administration of [U-{sup 13}C] glucose. Hearts were collected after 15 and 60 min and flux profiling was determined by measuring {sup 13}C mass isotopomers in glycolytic and tricarboxylic acid (TCA) cycle intermediates. Cardiac insulin resistance, determined by euglycemic–hyperinsulinemic clamp, was evident after 3 weeks of HFD. Despite the presence of insulin resistance, in vivo cardiac glucose metabolism following oral glucose administration was not compromised in HFD mice. This contrasts our recent findings in skeletal muscle, where TCA cycle activity was reduced in mice fed a HFD. Similar to our report in muscle, glucose derived pyruvate entry into the TCA cycle in the heart was almost exclusively via pyruvate dehydrogenase, with pyruvate carboxylase mediated anaplerosis being negligible after oral glucose administration. Conclusions: Under experimental conditions which closely mimic the postprandial state, the insulin resistant mouse heart retains the ability to stimulate glucose metabolism. - Highlights: • Insulin clamp was used to determine the evolution of cardiac

  17. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent...... of the 92 measurements obtained with the hypocount B were within +/- 20% of the laboratory glucose values. Using haemo-glucotest 1-44 strips, 74% of the readings were within +/- 20% of the reference laboratory values. For values below 5.5 mmol/l, there was a tendency for results to be too low, with 77......% of the readings below laboratory values -20%. All situations with severe hypoglycaemia were detected with both strips. The study also demonstrates the ineffectiveness of s.c. insulin regimens during surgery. Only 47% of the measured blood glucose values were within the range of 5.5-10 mmol/l and two of ten...

  18. Investigation of 18F-2-deoxyglucose for the measure of myocardial glucose metabolism

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.R.; Kuhl, D.E.

    1977-01-01

    18 F labeled 2-deoxyglucose ( 18 FDG) was studied as a glucose analog. Myocardial uptake and retention, blood clearance, species (dog, monkey, man) dependence and effect of diet on uptake were investigated. Normal myocardial uptake of 18 FDG was 3 to 4% in dog and monkey and 1 to 4% of injected dose in man compared to brain uptake of 2% in dog, 5 to 6% in monkey and 4 to 8% in man. The metabolic rate (MR) for glucose in non-fasting (glycolytic state) was 2.8 times greater than in fasting (ketogenic state). Human subjects showed higher myocardial uptake after a normal meal than after meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t 1 / 2 of 0.2 to 0.3 min followed by a t 1 / 2 of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had a t 1 / 2 of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. High image contrast ratios between heart and blood (dog 3.5/1; man 14/1), heart and lung (dog 9/1; man 20/1), heart and liver (dog 15/1; man 10/1) were found with the ECAT positron tomograph. 18 FDG was found to be rapidly taken up by the myocardium without any significant tissue clearance over a 4 hour period. 18 FDG is transported, phosphorylated to 18 FDG-6-PO 4 and trapped in myocardial cells in the same manner as has been found for brain and exhibits excellent imaging properties. Determination of glucose and FFA MR in vivo with ECT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man

  19. First coil for the SC

    CERN Multimedia

    CERN PhotoLab

    1955-01-01

    The coils for the SC magnet were stored in the large hangar of the Cointrin Airport (to make sure that they would be available before snow and ice would block the roads and canals from Belgium, where they were built).

  20. A Negative Correlation Between Blood Glucose and Acetone Measured in Healthy and Type 1 Diabetes Mellitus Patient Breath.

    Science.gov (United States)

    Rydosz, Artur

    2015-07-01

    Exhaled acetone analysis has long been recognized as a supplementary tool for diagnosis and monitoring diabetes, especially type 1 diabetes. It is essential, therefore to determine the relationship between exhaled acetone concentration and glucose in blood. Usually, a direct linear correlation between this both compounds has been expected. However, in some cases we can observe a reverse correlation. When blood glucose was increasing, breath acetone declined. The breath analysis as a supplementary tool for diagnosing and monitoring diabetes makes sense only in case of utilization of portable analyzers. This need has created a market for gas sensors. However, commercially available acetone gas sensors are developed for measuring samples at several tens part per million. The exhaled acetone concentration was measured using commercial acetone gas sensor (TGS 822, 823 Figaro, Arlington Heights, IL, USA Inc) with micropreconcentrator in low temperature cofired ceramics. The reference analyzer-mass spectrometry (HPR-20 QIC, Hiden Analytical, Warrington, UK) was used. Twenty-two healthy volunteers with no history of any respiratory disease participated in the research, as did 31 patients diagnosed with type 1 diabetes. Respectively, 3 healthy volunteer and 5 type 1 diabetes mellitus subjects with reverse trend were selected. The linear fitting coefficient various from 0.1139 to 0.9573. Therefore, it is necessary to determine the correlation between blood glucose concentrations and under different conditions, for example, insulin levels, as well as correlate the results with clinical tests, for example, Hb1Ac. It is well known that the concentration of acetone is strongly influenced by diet, insulin treatment, and so on. Therefore, much more complex analysis with long-term measurements are required. Thus, presented results should be regarded as tentative, and validation studies with the analysis of clinical test and in a large number of patients, including control groups

  1. Level densities and γ strength functions in light Sc and Ti isotopes

    International Nuclear Information System (INIS)

    Burger, A.; Larsen, A.C.; Syed, N.U.H.; Guttormsen, M.; Nyhus, H.; Siem, S.; Harissopulos, S.; Konstantinopoulos, T.; Lagoyannis, A.; Perdidakis, G.; Spyrou, A.; Kmiecik, M.; Mazurek, K.; Krticka, M.; Loennroth, T.; Norby, M.; Voinov, A.

    2010-01-01

    We present preliminary results from a measurement of nuclear level densities and the γ-ray strength of light Sc (Sc 43 , Sc 45 ) and Ti (Ti 44 , Ti 45 and Ti 46 ) isotopes using the Oslo Method. The article begins with a presentation of the experimental setup. (authors)

  2. Validation of different measures of insulin sensitivity of glucose metabolism in dairy cows using the hyperinsulinemic euglycemic clamp test as the gold standard.

    Science.gov (United States)

    De Koster, J; Hostens, M; Hermans, K; Van den Broeck, W; Opsomer, G

    2016-10-01

    The aim of the present research was to compare different measures of insulin sensitivity in dairy cows at the end of the dry period. To do so, 10 clinically healthy dairy cows with a varying body condition score were selected. By performing hyperinsulinemic euglycemic clamp (HEC) tests, we previously demonstrated a negative association between the insulin sensitivity and insulin responsiveness of glucose metabolism and the body condition score of these animals. In the same animals, other measures of insulin sensitivity were determined and the correlation with the HEC test, which is considered as the gold standard, was calculated. Measures derived from the intravenous glucose tolerance test (IVGTT) are based on the disappearance of glucose after an intravenous glucose bolus. Glucose concentrations during the IVGTT were used to calculate the area under the curve of glucose and the clearance rate of glucose. In addition, glucose and insulin data from the IVGTT were fitted in the minimal model to derive the insulin sensitivity parameter, Si. Based on blood samples taken before the start of the IVGTT, basal concentrations of glucose, insulin, NEFA, and β-hydroxybutyrate were determined and used to calculate surrogate indices for insulin sensitivity, such as the homeostasis model of insulin resistance, the quantitative insulin sensitivity check index, the revised quantitative insulin sensitivity check index and the revised quantitative insulin sensitivity check index including β-hydroxybutyrate. Correlation analysis revealed no association between the results obtained by the HEC test and any of the surrogate indices for insulin sensitivity. For the measures derived from the IVGTT, the area under the curve for the first 60 min of the test and the Si derived from the minimal model demonstrated good correlation with the gold standard. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    Science.gov (United States)

    Steinfelder-Visscher, J; Weerwind, P W; Teerenstra, S; Brouwer, M H J

    2006-01-01

    Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the GEM Premier 3000 was compared with the Ciba Corning 865 analyser for blood gas/electrolytes/metabolites, and for hematocrit with the Sysmex XE 2100 instrument. During a 6-month period, 127 blood samples were analysed on both the GEM Premier 3000 analyser and our laboratory analysers (Ciba Corning 865/Sysmex 2100 instrument), and compared using the agreement analysis for quantitative data. With the exception of K+, the other parameters (pCO2, pO2, Na+, Ca2+, hematocrit, glucose, and lactate) can be described in terms of the mean and standard deviation of the differences. For K+ measurement, a clear linear trend (r=0.79, panalyser seems to be suitable for point-of-care testing of electrolytes, metabolites, and blood gases during cardiopulmonary bypass. However, its downward bias in hematocrit values below 30% suggests that using the GEM Premier 3000 as a transfusion trigger leads to overtreatment with packed red cells.

  4. Glucose metabolism of fetal rat brain in utero, measured with labeled deoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Dyve, S [Department of General Physiology and Biophysics, Panum Institute, Copenhagen (Denmark); Gjedde, A [Positron Imaging Laboratories, McConnell Brain Imaging Center, Montreal, Quebec (Canada)

    1991-01-01

    Mammals have low cerebral metabolic rates immediately after birth and, by inference, also before birth. In this study, we extended the deoxyglucose method to the fetal rat brain in utero. Rate constants for deoxyglucose transfer across the maternal placental and fetal blood-brain barriers, and lumped constant, have not been reported. Therefore, we applied a new method of determining the lumped constant regionally to the fetal rat brain in utero. The lumped constant averaged 0.55 +- 0.15 relative to the maternal circulation. On this basis, we determined the glucose metabolic rate of the fetal rat brain to be one third of the corresponding maternal value, or 19 +- 2 {mu}mol hg{sup -1} min{sup -1}. (author).

  5. Influence of Iatrogenic Gaps, Cement Type, and Time on Microleakage of Cast Posts Using Spectrophotometer and Glucose Filtration Measurements.

    Science.gov (United States)

    Al-Madi, Ebtissam M; Al-Saleh, Samar A; Al-Khudairy, Reem I; Aba-Hussein, Taibah W

    2018-04-06

    To determine the influence of iatrogenic gaps, type of cement, and time on microleakage of cast posts using spectrophotometer and glucose filtration measurements. Forty-eight single-rooted teeth were divided into eight groups of six teeth each. Teeth were instrumented and obturated, and a cast post was fabricated. In addition to two control groups (positive and negative), a total of six groups were prepared: In four groups, an artificial 2- to 3-mm gap was created between post and residual gutta percha (GP), and two groups were prepared with intimate contact between post and residual GP. Posts were cemented with either zinc phosphate cement or resin cement. Leakage through the post after 1, 8, 14, and 20 days was measured using a glucose penetration model with two different reading methods. Mixed analysis of variance tests were performed to analyze the data. The presence of a gap between the apical end of the post and the most coronal portion of the GP remaining in the root canal after post space preparation increased microleakage significantly. However, microleakage was significantly less when the gap was refilled with GP compared to no gap. There was no difference in leakage between luting cements used. It was concluded that none of the cements were able to prevent microleakage. However, the addition of GP to residual GP did increase the sealing ability.

  6. In-vivo measurements of regional acetylcholine esterase activity in degenerative dementia: comparison with blood flow and glucose metabolism.

    Science.gov (United States)

    Herholz, K; Bauer, B; Wienhard, K; Kracht, L; Mielke, R; Lenz, M O; Strotmann, T; Heiss, W D

    2000-01-01

    Memory and attention are cognitive functions that depend heavily on the cholinergic system. Local activity of acetylcholine esterase (AChE) is an indicator of its integrity. Using a recently developed tracer for positron emission tomography (PET), C-11-labeled N-methyl-4-piperidyl-acetate (C11-MP4A), we measured regional AChE activity in 4 non-demented subjects, 4 patients with dementia of Alzheimer type (DAT) and 1 patient with senile dementia of Lewy body type (SDLT), and compared the findings with measurements of blood flow (CBF) and glucose metabolism (CMRGlc). Initial tracer extraction was closely related to CBF. AChE activity was reduced significantly in all brain regions in demented subjects, whereas reduction of CMRGlc and CBF was more limited to temporo-parietal association areas. AChE activity in SDLT was in the lower range of values in DAT. Our results indicate that, compared to non-demented controls, there is a global reduction of cortical AChE activity in dementia. Dementia, cholinergic system, acetylcholine esterase, positron emission tomography, cerebral blood flow, cerebral glucose metabolism.

  7. Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

    OpenAIRE

    Hwang, Joon Ho; Sohn, Yong-Hak; Chang, Seong-Sil; Kim, Seung Yeon

    2015-01-01

    Purpose We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Methods Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ≤2,300 g or were ≤36 weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson &...

  8. Comparison of a Point-of-Care Glucometer and a Laboratory Autoanalyzer for Measurement of Blood Glucose Concentrations in Domestic Pigeons ( Columba livia domestica).

    Science.gov (United States)

    Mohsenzadeh, Mahdieh Sadat; Zaeemi, Mahdieh; Razmyar, Jamshid; Azizzadeh, Mohammad

    2015-09-01

    Biochemical analysis is necessary for diagnosis and monitoring of diseases in birds; however, the small volume of blood that can be safely obtained from small avian species often limits laboratory diagnostic testing. Consequently, a suitable methodology requiring only a small volume of blood must be used. This study was designed to compare blood glucose concentrations in domestic pigeons ( Columba livia domestica) as measured by a commercial, handheld, human glucometer and a standard autoanalyzer. During the first phase of the study, whole blood samples obtained from 30 domestic pigeons were used to measure the blood glucose concentration with a glucometer, the packed cell volume (PCV), and the total erythrocyte count (nRBC). Plasma separated from the each sample was then used to obtain the plasma glucose concentration with the autoanalyzer. During the second phase of the study, 30 pigeons were assigned to 2 equal groups (n = 15). Hypoglycemia or hyperglycemia was induced in each group by intravenous injection of insulin or glucose, respectively. Blood was collected and processed, and glucose concentrations, PCV, and nRBC were measured as previously described. Linear-regression models demonstrated a significant relationship between results measured by the glucometer and autoanalyzer results from normoglycemic (correlation coefficient [R] = 0.43, P = .02), hypoglycemic (R = 0.95; P < .001), and hyperglycemic (R = 0.81; P < .001) birds. The results of this study suggest that we can predict the real blood-glucose concentration of pigeons by using results obtained by a glucometer.

  9. High-resolution clean-sc

    NARCIS (Netherlands)

    Sijtsma, P.; Snellen, M.

    2016-01-01

    In this paper a high-resolution extension of CLEAN-SC is proposed: HR-CLEAN-SC. Where CLEAN-SC uses peak sources in “dirty maps” to define so-called source components, HR-CLEAN-SC takes advantage of the fact that source components can likewise be derived from points at some distance from the peak,

  10. Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes

    DEFF Research Database (Denmark)

    Law, Graham R; Gilthorpe, Mark S; Secher, Anna L

    2017-01-01

    AIMS/HYPOTHESIS: This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA1c measureme...

  11. Breakthrough scenarios to Finnish elderly and home care diabetes treatment system with a new mHealth glucose measurement solution Mendor Balance & Mendor Smart

    OpenAIRE

    Ahola, Antti

    2016-01-01

    This paper is a qualitative market segment research of an existing product combination for monitoring blood glucose values of diabetic people with a cellular network connected device with cloud application on reporting and analysis. Research attempts to answer to four main questions. What are the current and future technological requirements from glucose measurement devices, services and diabetes home care solutions? Which specific groups of customers or other stakeholders in assisted living ...

  12. Optimized methods to measure acetoacetate, 3-hydroxybutyrate, glycerol, alanine, pyruvate, lactate and glucose in human blood using a centrifugal analyser with a fluorimetric attachment

    OpenAIRE

    Stappenbeck, R.; Hodson, A. W.; Skillen, A. W.; Agius, L.; Alberti, K. G. M. M.

    1990-01-01

    Optimized methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, D-3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood using the Cobas Bio centrifugal analyser. Glucose and lactate are measured using the photometric mode and other metabolites using the fluorimetric mode. The intra-assay coefficients of variation ranged from 0.7 to 4.1%, except with very low levels of pyruvate and acetoacetate where the coefficients of variation were ...

  13. Modulation of parathion toxicity by glucose feeding: Is nitric oxide involved?

    International Nuclear Information System (INIS)

    Liu Jing; Gupta, Ramesh C.; Goad, John T.; Karanth, Subramanya; Pope, Carey

    2007-01-01

    Glucose feeding can markedly exacerbate the toxicity of the anticholinesterase insecticide, parathion. We determined the effects of parathion on brain nitric oxide and its possible role in potentiation of toxicity by glucose feeding. Adult rats were given water or 15% glucose in water for 3 days and challenged with vehicle or parathion (18 mg/kg, s.c.) on day 4. Functional signs, plasma glucose and brain cholinesterase, citrulline (an indicator of nitric oxide production) and high-energy phosphates (HEPs) were measured 1-3 days after parathion. Glucose feeding exacerbated cholinergic toxicity. Parathion increased plasma glucose (15-33%) and decreased cortical cholinesterase activity (81-90%), with no significant differences between water and glucose treatment groups. In contrast, parathion increased brain regional citrulline (40-47%) and decreased HEPs (18-40%) in rats drinking water, with significantly greater changes in glucose-fed rats (248-363% increase and 31-61% decrease, respectively). We then studied the effects of inhibiting neuronal nitric oxide synthase (nNOS) by 7-nitroindazole (7NI, 30 mg/kg, i.p. x4) on parathion toxicity and its modulation by glucose feeding. Co-exposure to parathion and 7NI led to a marked increase in cholinergic signs of toxicity and lethality, regardless of glucose intake. Thus, glucose feeding enhanced the accumulation of brain nitric oxide following parathion exposure, but inhibition of nitric oxide synthesis was ineffective at counteracting increased parathion toxicity associated with glucose feeding. Evidence is therefore presented to suggest that nitric oxide may play both toxic and protective roles in cholinergic toxicity, and its precise contribution to modulation by glucose feeding requires further investigation

  14. Effect of postprandial hyperglycaemia in non-invasive measurement of cerebral metabolic rate of glucose in non-diabetic subjects

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchida, Tatsuro; Itoh, Harumi [Department of Radiology, Fukui Medical University, Matsuoka (Japan); Sadato, Norihiro; Nishizawa, Sadahiko; Yonekura, Yoshiharu [Biomedical Imaging Research Center, Fukui Medical University (Japan)

    2002-02-01

    The aim of this study was to determine the effect of postprandial hyperglycaemia (HG) on the non-invasive measurement of cerebral metabolic rate of glucose (CMRGlc). Five patients who had a meal within an hour before a fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) examination were recruited in this study. They underwent intermittent arterial blood sampling (measured input function), and, based on this sampling, CMRGlc was calculated using an autoradiographic method (CMRGlc{sub real}). Simulated input functions were generated based on standardised input function, body surface area and net injected dose of FDG, and simulated CMRGlc (CMRGlc{sub sim}) was also calculated. Percent error of the area under the curve (AUC) between measured (AUC{sub real}) and simulated input function (AUC{sub IFsim}) and percent error between CMRGlc{sub real} and CMRGlc{sub sim} were calculated. These values were compared with those obtained from a previous study conducted under fasting conditions (F). The serum glucose level in the HG group was significantly higher than that in the F group (165{+-}69 vs 100{+-}9 mg/dl, P=0.0007). Percent errors of AUC and CMRGlc in grey matter and white matter in HG were significantly higher than those in F (12.9%{+-}1.3% vs 3.5%{+-}2.2% in AUC, P=0.0015; 18.2%{+-}2.2% vs 2.9%{+-}1.9% in CMRGlc in grey matter, P=0.0028; 24.0%{+-}4.6% vs 3.4%{+-}2.2% in CMRGlc in white matter, P=0.0028). It is concluded that a non-invasive method of measuring CMRGlc should be applied only in non-diabetic subjects under fasting conditions. (orig.)

  15. Effect of postprandial hyperglycaemia in non-invasive measurement of cerebral metabolic rate of glucose in non-diabetic subjects

    International Nuclear Information System (INIS)

    Tsuchida, Tatsuro; Itoh, Harumi; Sadato, Norihiro; Nishizawa, Sadahiko; Yonekura, Yoshiharu

    2002-01-01

    The aim of this study was to determine the effect of postprandial hyperglycaemia (HG) on the non-invasive measurement of cerebral metabolic rate of glucose (CMRGlc). Five patients who had a meal within an hour before a fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) examination were recruited in this study. They underwent intermittent arterial blood sampling (measured input function), and, based on this sampling, CMRGlc was calculated using an autoradiographic method (CMRGlc real ). Simulated input functions were generated based on standardised input function, body surface area and net injected dose of FDG, and simulated CMRGlc (CMRGlc sim ) was also calculated. Percent error of the area under the curve (AUC) between measured (AUC real ) and simulated input function (AUC IFsim ) and percent error between CMRGlc real and CMRGlc sim were calculated. These values were compared with those obtained from a previous study conducted under fasting conditions (F). The serum glucose level in the HG group was significantly higher than that in the F group (165±69 vs 100±9 mg/dl, P=0.0007). Percent errors of AUC and CMRGlc in grey matter and white matter in HG were significantly higher than those in F (12.9%±1.3% vs 3.5%±2.2% in AUC, P=0.0015; 18.2%±2.2% vs 2.9%±1.9% in CMRGlc in grey matter, P=0.0028; 24.0%±4.6% vs 3.4%±2.2% in CMRGlc in white matter, P=0.0028). It is concluded that a non-invasive method of measuring CMRGlc should be applied only in non-diabetic subjects under fasting conditions. (orig.)

  16. Blood glucose measurement in patients with suspected diabetic ketoacidosis: a comparison of Abbott MediSense PCx point-of-care meter values to reference laboratory values.

    Science.gov (United States)

    Blank, Fidela S J; Miller, Moses; Nichols, James; Smithline, Howard; Crabb, Gillian; Pekow, Penelope

    2009-04-01

    The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100,000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.

  17. Sc-45 nuclear magnetic resonance analysis of precipitation in dilute Al-Sc alloys

    NARCIS (Netherlands)

    Celotto, S; Bastow, TJ

    Nuclear magnetic resonance (NMR) with Sc-45 is used to determine the solid solubility of scandium in aluminium and to follow the precipitation of Al3Sc during the ageing of an Al-0.06 at.% Sc alloy via the two fully resolved peaks, corresponding to Sc in the solid solution Al matrix and to Sc in the

  18. First measurement of the nonlinear coefficient for Gd1-xLux Ca4O(BO3)3 and Gd1-xScxCa4O(BO3)3 crystals

    DEFF Research Database (Denmark)

    Andersen, Martin Thalbitzer; Mortensen, Jesper Liltorp; Germershausen, Sven

    2007-01-01

    The effective nonlinear coefficient and temperature acceptance bandwidth of three Lu and Sc co-doped GdCa4O(B03)3 type nonlinear crystals were measured. NCPM for SHG in to the blue-UV spectral region can be obtained by controlling the co-dopant concentration. Measurements were based on intra-cavi...

  19. [Roberts-SC phocomelia syndrome].

    Science.gov (United States)

    Musfeld, D A; Bühler, E M; Heinzl, S

    2001-01-01

    The Roberts-SC phocomelia syndrome is a rare autosomal recessive inherited disorder clinically manifested by tetraphocomelia, pre- and postnatal growth retardation, and craniofacial abnormalities (skull, eyes, lip, and palate), accompanied at times by centromer puffing and splitting, renal abnormalities, heart defect, clitoral or penile enlargement, and bilateral corneal opacities. Mental retardation is common in surviving patients.

  20. Rotary condenser for SC2

    CERN Multimedia

    1975-01-01

    During 1975 the SC2 performance was improved among other things by redesigning some of the elements of the ROTCO (Annual Report 1975, p. 55). The photo shows an interior wiew of the housing of the rotary condenser and of the sixteen sets of shaped stator blades.

  1. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US .... Arterial blood pressure from nonvascular access arm was measured by aneroid sphygmomanometer. The patients did not .... to detect differences in treatments across multiple test attempts. P < 0.05 ...

  2. Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling

    DEFF Research Database (Denmark)

    Munk, O L; Bass, L; Roelsgaard, K

    2001-01-01

    -input functions were very similar. CONCLUSION: Compartmental analysis of MG and FDG kinetics using dynamic PET data requires measurements of dual-input activity concentrations. Using the dual-input function, physiologically reasonable parameter estimates of K1, k2, and Vp were obtained, whereas the use......Metabolic processes studied by PET are quantified traditionally using compartmental models, which relate the time course of the tracer concentration in tissue to that in arterial blood. For liver studies, the use of arterial input may, however, cause systematic errors to the estimated kinetic...... parameters, because of ignorance of the dual blood supply from the hepatic artery and the portal vein to the liver. METHODS: Six pigs underwent PET after [15O]carbon monoxide inhalation, 3-O-[11C]methylglucose (MG) injection, and [18F]FDG injection. For the glucose scans, PET data were acquired for 90 min...

  3. Precipitation in cold-rolled Al-Sc-Zr and Al-Mn-Sc-Zr alloys prepared by powder metallurgy

    KAUST Repository

    Vlach, Martin

    2013-12-01

    The effects of cold-rolling on thermal, mechanical and electrical properties, microstructure and recrystallization behaviour of the AlScZr and AlMnScZr alloys prepared by powder metallurgy were studied. The powder was produced by atomising in argon with 1% oxygen and then consolidated by hot extrusion at 350 C. The electrical resistometry and microhardness together with differential scanning calorimetry measurements were compared with microstructure development observed by transmission and scanning electron microscopy, X-ray diffraction and electron backscatter diffraction. Fine (sub)grain structure developed and fine coherent Al3Sc and/or Al3(Sc,Zr) particles precipitated during extrusion at 350 C in the alloys studied. Additional precipitation of the Al3Sc and/or Al3(Sc,Zr) particles and/or their coarsening was slightly facilitated by the previous cold rolling. The presence of Sc,Zr-containing particles has a significant antirecrystallization effect that prevents recrystallization at temperatures minimally up to 420 C. The precipitation of the Al6Mn- and/or Al 6(Mn,Fe) particles of a size ~ 1.0 μm at subgrain boundaries has also an essential antirecrystallization effect and totally suppresses recrystallization during 32 h long annealing at 550 C. The texture development of the alloys seems to be affected by high solid solution strengthening by Mn. The precipitation of the Mn-containing alloy is highly enhanced by a cold rolling. The apparent activation energy of the Al3Sc particles formation and/or coarsening and that of the Al6Mn and/or Al 6(Mn,Fe) particle precipitation in the powder and in the compacted alloys were determined. The cold deformation has no effect on the apparent activation energy values of the Al3Sc-phase and the Al 6Mn-phase precipitation. © 2013 Elsevier Inc.

  4. Precipitation in cold-rolled Al-Sc-Zr and Al-Mn-Sc-Zr alloys prepared by powder metallurgy

    KAUST Repository

    Vlach, Martin; Stulí ková , Ivana; Smola, Bohumil; Kekule, Tomá š; Kudrnová , Hana; Daniš, Stanislav; Gemma, Ryota; Očená šek, Vladivoj; Má lek, Jaroslav; Tanprayoon, Dhritti; Neubert, Volkmar

    2013-01-01

    The effects of cold-rolling on thermal, mechanical and electrical properties, microstructure and recrystallization behaviour of the AlScZr and AlMnScZr alloys prepared by powder metallurgy were studied. The powder was produced by atomising in argon with 1% oxygen and then consolidated by hot extrusion at 350 C. The electrical resistometry and microhardness together with differential scanning calorimetry measurements were compared with microstructure development observed by transmission and scanning electron microscopy, X-ray diffraction and electron backscatter diffraction. Fine (sub)grain structure developed and fine coherent Al3Sc and/or Al3(Sc,Zr) particles precipitated during extrusion at 350 C in the alloys studied. Additional precipitation of the Al3Sc and/or Al3(Sc,Zr) particles and/or their coarsening was slightly facilitated by the previous cold rolling. The presence of Sc,Zr-containing particles has a significant antirecrystallization effect that prevents recrystallization at temperatures minimally up to 420 C. The precipitation of the Al6Mn- and/or Al 6(Mn,Fe) particles of a size ~ 1.0 μm at subgrain boundaries has also an essential antirecrystallization effect and totally suppresses recrystallization during 32 h long annealing at 550 C. The texture development of the alloys seems to be affected by high solid solution strengthening by Mn. The precipitation of the Mn-containing alloy is highly enhanced by a cold rolling. The apparent activation energy of the Al3Sc particles formation and/or coarsening and that of the Al6Mn and/or Al 6(Mn,Fe) particle precipitation in the powder and in the compacted alloys were determined. The cold deformation has no effect on the apparent activation energy values of the Al3Sc-phase and the Al 6Mn-phase precipitation. © 2013 Elsevier Inc.

  5. Leishmania amazonensis chemotaxis under glucose gradient studied by the strength and directionality of forces measured with optical tweezers

    Science.gov (United States)

    de Ysasa Pozzo, Liliana; Fontes, Adriana; de Thomaz, André A.; Barbosa, Luiz Carlos; Ayres, Diana Copi; Giorgio, Selma; Cesar, Carlos Lenz

    2007-02-01

    Chemotaxis is the mechanism microorganisms use to sense the environment surrounding them and to direct their movement towards attractive, or away from the repellent, chemicals. The biochemical sensing is almost the only way for communication between unicellular organisms. Prokaryote and Eukaryote chemotaxis has been mechanically studied mainly by observing the directionality and timing of the microorganisms movements subjected to a chemical gradient, but not through the directionality and strength of the forces it generates. To observe the vector force of microorganisms under a chemical gradient we developed a system composed of two large chambers connected by a tiny duct capable to keep the chemical gradient constant for more than ten hours. We also used the displacements of a microsphere trapped in an Optical Tweezers as the force transducer to measure the direction and the strength of the propulsion forces of flagellum of the microorganism under several gradient conditions. A 9μm diameter microsphere particle was trapped with a Nd:YAG laser and its movement was measured through the light scattered focused on a quadrant detector. We observed the behavior of the protozoa Leishmania amazonensis (eukaryote) under several glucose gradients. This protozoa senses the gradient around it by swimming in circles for three to five times following by tumbling, and not by the typical straight swimming/tumbling of bacteria. Our results also suggest that force direction and strength are also used to control its movement, not only the timing of swimming/tumbling, because we observed a higher force strength clearly directed towards the glucose gradient.

  6. [Measurement of regional cerebral metabolism rate of glucose in patients with Alzheimer's disease in different levels of severity].

    Science.gov (United States)

    Xiao, Shi-fu; Cao, Qiu-yun; Xue, Hai-bo; Liu, Yong-chang; Zuo, Chuan-tao; Jiang, Kai-da; Zhang, Ming-yuan

    2005-11-09

    To measure the changes of regional cerebral metabolism rate of glucose (rCMRglc) in patients with Alzheimer's disease (AD) and explore their value to diagnosis of AD. 10 patients with AD who met the diagnostic criteria of DSM-IV and 10 normal controls (NC) were assessed with (18)F-2-fluoro-deoxy-D-glucose positron emission tomography (PET). The two groups were matched in age, gender and education. The mean total scores of the mini-mental status examination (MMSE) were 16.5 +/- 6.1 for AD and 28.7 +/- 1.6 for NC. The mean total memory quotient of Wechsler Memory Scales (MQ) were 32.3 +/- 19.6 for AD and 93.1 +/- 9.0 for NC. Comparing to NC, the AD groups showed statistically significant decline of rCMRglc in frontal lobe, temporal lobe and the hippocampal formation with decreased rates ranged from 3.3% to 28.4% (P upper and middle frontal gyri, middle temporal gyrus, orbital gyrus and anterior cingulate gyrus, in which areas the metabolism decreased over 20% compared to NC. The hypo-metabolism was correlated to the severity of dementia. Discriminant analysis demonstrated that the variables of right inferior temporal gyrus, left upper temporal gyrus, left hippocampus and right insular lobe were entered into the discriminant functions and the total discriminant accuracy reached 100%. (18)F-FDG PET is a very sensitive tool in measurement of the changes of rCMRglc in patients with AD. The findings show a frontal-temporal type of metabolism in AD patients and suggest that hypo-metabolism in hippocampal formation and temporal lobe is helpful in early detection of AD.

  7. Determination of 46Sc in water

    International Nuclear Information System (INIS)

    Huo Bijun; Ji Zhaogang; Wang Juying

    1985-01-01

    Analytical procedures for the determination of 46 Sc in water is presented. 46 Sc in water is concentrated with Fe(OH) 3 ; Then 46 Sc is extracted with TBP and purified by precipitating it with Amygdalic Acid. Finally the precipitate is ignited into Sc 2 O 3 under 800 deg C and β-activity is counted. In this method chemical reeovery for Sc was (90.8 +- 2.8)% and radiochemical recovery for 46 Sc was (89.8 +- 3.8)%. Purification factors for some of the relevant Radionuclides ranged from 10 3 to 10 5

  8. Glucose Sensing

    CERN Document Server

    Geddes, Chris D

    2006-01-01

    Topics in Fluorescence Spectroscopy, Glucose Sensing is the eleventh volume in the popular series Topics in Fluorescence Spectroscopy, edited by Drs. Chris D. Geddes and Joseph R. Lakowicz. This volume incorporates authoritative analytical fluorescence-based glucose sensing reviews specialized enough to be attractive to professional researchers, yet also appealing to the wider audience of scientists in related disciplines of fluorescence. Glucose Sensing is an essential reference for any lab working in the analytical fluorescence glucose sensing field. All academics, bench scientists, and industry professionals wishing to take advantage of the latest and greatest in the continuously emerging field of glucose sensing, and diabetes care & management, will find this volume an invaluable resource. Topics in Fluorescence Spectroscopy Volume 11, Glucose Sensing Chapters include: Implantable Sensors for Interstitial Fluid Smart Tattoo Glucose Sensors Optical Enzyme-based Glucose Biosensors Plasmonic Glucose Sens...

  9. Associations between ultrasound measures of abdominal fat distribution and indices of glucose metabolism in a population at high risk of type 2 diabetes: the ADDITION-PRO study.

    Directory of Open Access Journals (Sweden)

    Annelotte Philipsen

    Full Text Available Visceral adipose tissue measured by CT or MRI is strongly associated with an adverse metabolic risk profile. We assessed whether similar associations can be found with ultrasonography, by quantifying the strength of the relationship between different measures of obesity and indices of glucose metabolism in a population at high risk of type 2 diabetes.A cross-sectional analysis of 1342 participants of the ADDITION-PRO study. We measured visceral adipose tissue and subcutaneous adipose tissue with ultrasonography, anthropometrics and body fat percentage by bioelectrical impedance. Indices of glucose metabolism were derived from a three point oral glucose tolerance test. Linear regression of obesity measures on indices of glucose metabolism was performed.Mean age was 66.2 years, BMI 26.9kg/m2, subcutaneous adipose tissue 2.5cm and visceral adipose tissue 8.0cm. All measures of obesity were positively associated with indicators of glycaemia and inversely associated with indicators of insulin sensitivity. Associations were of equivalent magnitude except for subcutaneous adipose tissue and the visceral/subcutaneous adipose tissue ratio, which showed weaker associations. One standard deviation difference in BMI, visceral adipose tissue, waist circumference, waist/height ratio and body fat percentage corresponded approximately to 0.2mmol/l higher fasting glucose, 0.7mmol/l higher 2-hr glucose, 0.06-0.1% higher HbA1c, 30 % lower HOMA index of insulin sensitivity, 20% lower Gutt's index of insulin sensitivity, and 100 unit higher Stumvoll's index of beta-cell function. After adjustment for waist circumference visceral adipose tissue was still significantly associated with glucose intolerance and insulin resistance, whereas there was a trend towards inverse or no associations with subcutaneous adipose tissue. After adjustment, a 1cm increase in visceral adipose tissue was associated with ~5% lower insulin sensitivity (p≤0.0004 and ~0.18mmol/l higher 2-hr

  10. Antecedent caloric intake and glucose excursion following a subsequent meal in Type 1 diabetes.

    Science.gov (United States)

    Mehra, Rinku; Raman, Ramesh; Bayless, Margaret L; Sivitz, William I

    2009-12-01

    In the present study, we tested the hypothesis that calories consumed at a prior meal (lunch) may impair glycemic control after a subsequent meal (supper) even if the pre-supper glucose did not differ regardless of the size of the lunch meal. Nine subjects with Type 1 diabetes using continuous subcutaneous (s.c.) insulin infusion (CSII) therapy were studied on two separate days. Lunch (1200 h) was randomly assigned as 25% or 50% of the usual daily intake on alternate study days. The CSII was stopped at 1000 h on the day of the study and glucose was controlled until supper by adjusting the rate of intravenous (i.v.) insulin based on glucose measurements every 15 min. The CSII was restarted 1 h before supper and i.v. insulin discontinued 15 min before the first bite of supper. An identical supper meal and pre-supper s.c. bolus of short-acting insulin were administered on both visits. Pre-supper glycemia was nearly identical on each of the two study days. However, the post-supper glucose area under the curve was 27.5% greater on the day of the antecedent large lunch compared with the small lunch (P = 0.0039). For optimal postprandial glucose control, people with Type 1 diabetes may need to consider not only anticipated meal calories, but also prior food intake, a practice not commonly recommended based on currently used insulin dosing algorithms.

  11. Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.

    Science.gov (United States)

    Megahed, A A; Hiew, M W H; Townsend, J R; Messick, J B; Constable, P D

    2015-01-01

    The Precision Xtra(®) meter is a promising low cost electrochemical point-of-care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra-erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. A total of 106 periparturient Holstein-Friesian cattle. Blood and plasma samples (1,109) were obtained and Deming regression and Bland-Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Intra-erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle-specific algorithm is developed, we recommend using plasma as the analyte instead of blood and calculating plasma [gluc] using the equation: [gluc] = 0.66 × [gluc]p-meter + 15, where [gluc]p-meter is the value reported by the meter. If blood is measured, then we recommend using the equation: [gluc] = 0.90 × [gluc]b-meter + 15. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  12. Prevalence of positive urinary dipstick analysis (leucocyte esterase, nitrite, haemoglobin, or glucose) in a population of 3645 adult subjects--consequence for measurement of urinary albumin excretion rate

    DEFF Research Database (Denmark)

    Clausen, P; Jensen, J S; Borch-Johnsen, K

    1998-01-01

    OBJECTIVES: To assess prevalence of positive urinary dipstick analysis for leucocyte esterase, nitrite, haemoglobin, or glucose in the general population and measure the urinary albumin excretion rate (UAER) in subjects with or without a positive dipstick analysis. DESIGN: A cross-sectional study...... of 3645 subjects. SETTING: An unselected urban population study. MAIN OUTCOME MEASURES: Prevalence data of positive dipstick analyses and UAER values. RESULTS: Prevalence data of a positive dipstick analysis were 12%, 4%, 3% and 6%, respectively, for leucocyte esterase, nitrite, haemoglobin, and glucose...

  13. Measurement of direct CP violation in b → sc(bar c) and b → dc(bar c) quark transitions using B+ → J/ψK+ and B+ → J/ψπ+ decays

    International Nuclear Information System (INIS)

    Holubyev, K.

    2008-01-01

    This thesis describes the measurement of the direct CP violation in the b → sc(bar c) transition using the decay B + → J/ψK + , and in the b → dc(bar c) transition using the decay B + → J/ψπ + . The decays of B + mesons are reconstructed in approximately 2.8 fb -1 of data recorded by D0 detector in 2002-2007 during Run II of Fermilab Tevatron collider. Using the unbinned likelihood fit, a signal of 40,222 ± 242 of B + → J/ψK + and 1,578 ± 119 of B + → J/ψπ + events is obtained. The corresponding direct CP violation asymmetries are measured to be A CP (B + → J/ψ(1S)K + ) = +0.0077 ± 0.0061(stat.) ± 0.0027(syst.), and A CP (B + → J/ψ(1S)π + ) = - 0.089 ± 0.081(stat.) ± 0.028(syst.). The result on A CP (B + → J/ψ(1S)K + ) is consistent with the 2007 world average and is the most precise measurement of this asymmetry, with uncertainty approaching the level of the Standard Model prediction. The result on A CP (B + → J/ψ(1S)π + ) constitutes the first measurement of this asymmetry at the hadron collider, with uncertainty at the level of the 2007 world average. The measurement presented in this thesis has become possible due to the sophisticated online and offline tracking/vertexing implemented at D0, and the regular reversal of the polarities of the D0 detector magnets.

  14. Evaluation of fasting state-/oral glucose tolerance test-derived measures of insulin release for the detection of genetically impaired β-cell function.

    Directory of Open Access Journals (Sweden)

    Silke A Herzberg-Schäfer

    Full Text Available BACKGROUND: To date, fasting state- and different oral glucose tolerance test (OGTT-derived measures are used to estimate insulin release with reasonable effort in large human cohorts required, e.g., for genetic studies. Here, we evaluated twelve common (or recently introduced fasting state-/OGTT-derived indices for their suitability to detect genetically determined β-cell dysfunction. METHODOLOGY/PRINCIPAL FINDINGS: A cohort of 1364 White European individuals at increased risk for type 2 diabetes was characterized by OGTT with glucose, insulin, and C-peptide measurements and genotyped for single nucleotide polymorphisms (SNPs known to affect glucose- and incretin-stimulated insulin secretion. One fasting state- and eleven OGTT-derived indices were calculated and statistically evaluated. After adjustment for confounding variables, all tested SNPs were significantly associated with at least two insulin secretion measures (p≤0.05. The indices were ranked according to their associations' statistical power, and the ranks an index obtained for its associations with all the tested SNPs (or a subset were summed up resulting in a final ranking. This approach revealed area under the curve (AUC(Insulin(0-30/AUC(Glucose(0-30 as the best-ranked index to detect SNP-dependent differences in insulin release. Moreover, AUC(Insulin(0-30/AUC(Glucose(0-30, corrected insulin response (CIR, AUC(C-Peptide(0-30/AUC(Glucose(0-30, AUC(C-Peptide(0-120/AUC(Glucose(0-120, two different formulas for the incremental insulin response from 0-30 min, i.e., the insulinogenic indices (IGI(2 and IGI(1, and insulin 30 min were significantly higher-ranked than homeostasis model assessment of β-cell function (HOMA-B; p<0.05. AUC(C-Peptide(0-120/AUC(Glucose(0-120 was best-ranked for the detection of SNPs involved in incretin-stimulated insulin secretion. In all analyses, HOMA-β displayed the highest rank sums and, thus, scored last. CONCLUSIONS/SIGNIFICANCE: With AUC(Insulin(0

  15. Mean activity coefficient measurement and thermodynamic modelling of the ternary mixed electrolyte (MgCl_2 + glucose + water) system at T = 298.15 K

    International Nuclear Information System (INIS)

    Rouhi, Azam; Bagherinia, Mohammad Ali

    2015-01-01

    Highlights: • The main goal of the work is to provide precise thermodynamic data for the system. • The method used was potentiometric method. • Pitzer ion interaction model and modified TCPC model were used. • The mass fractions of glucose were (0, 10, 20, 30 and 40)%. • The ionic strengths were from 0.0010 to 6.0000 mol · kg"−"1. - Abstract: In this work, the mean activity coefficients of MgCl_2 in pure water and (glucose + water) mixture solvent were determined using a galvanic cell without liquid junction potential of type: (Mg"2"+ + ISE)|MgCl_2 (m), glucose (wt.%), H_2O (100 wt.%)|AgCl|Ag. The measurements were performed at T = 298.15 K. Total ionic strengths were from (0.0010 to 6.0000) mol · kg"−"1. The various (glucose + water) mixed solvents contained (0, 10, 20, 30 and 40)% mass fractions percentage of glucose respectively. The mean activity coefficients measured were correlated with Pitzer ion interaction model and the Pitzer adjustable parameters were determined. Then these parameters were used to calculate the thermodynamics properties for under investigated system. The results showed that Pitzer ion interaction model can satisfactory describe the investigated system. The modified three-characteristic-parameter correlation (TCPC) model was applied to correlate the experimental activity coefficient data for under investigation electrolyte system, too.

  16. Blood Glucose Determination

    DEFF Research Database (Denmark)

    Lippi, Giuseppe; Nybo, Mads; Cadamuro, Janne

    2018-01-01

    The measurement of fasting plasma glucose may be biased by a time-dependent decrease of glucose in blood tubes, mainly attributable to blood cell metabolism when glycolysis is not rapidly inhibited or blood cells cannot be rapidly separated from plasma. Although glycolysis inhibitors such as sodium...

  17. Compensation of native donor doping in ScN: Carrier concentration control and p-type ScN

    Science.gov (United States)

    Saha, Bivas; Garbrecht, Magnus; Perez-Taborda, Jaime A.; Fawey, Mohammed H.; Koh, Yee Rui; Shakouri, Ali; Martin-Gonzalez, Marisol; Hultman, Lars; Sands, Timothy D.

    2017-06-01

    Scandium nitride (ScN) is an emerging indirect bandgap rocksalt semiconductor that has attracted significant attention in recent years for its potential applications in thermoelectric energy conversion devices, as a semiconducting component in epitaxial metal/semiconductor superlattices and as a substrate material for high quality GaN growth. Due to the presence of oxygen impurities and native defects such as nitrogen vacancies, sputter-deposited ScN thin-films are highly degenerate n-type semiconductors with carrier concentrations in the (1-6) × 1020 cm-3 range. In this letter, we show that magnesium nitride (MgxNy) acts as an efficient hole dopant in ScN and reduces the n-type carrier concentration, turning ScN into a p-type semiconductor at high doping levels. Employing a combination of high-resolution X-ray diffraction, transmission electron microscopy, and room temperature optical and temperature dependent electrical measurements, we demonstrate that p-type Sc1-xMgxN thin-film alloys (a) are substitutional solid solutions without MgxNy precipitation, phase segregation, or secondary phase formation within the studied compositional region, (b) exhibit a maximum hole-concentration of 2.2 × 1020 cm-3 and a hole mobility of 21 cm2/Vs, (c) do not show any defect states inside the direct gap of ScN, thus retaining their basic electronic structure, and (d) exhibit alloy scattering dominating hole conduction at high temperatures. These results demonstrate MgxNy doped p-type ScN and compare well with our previous reports on p-type ScN with manganese nitride (MnxNy) doping.

  18. Associations between Ultrasound Measures of Abdominal Fat Distribution and Indices of Glucose Metabolism in a Population at High Risk of Type 2 Diabetes: The ADDITION-PRO Study

    DEFF Research Database (Denmark)

    Philipsen, Annelotte; Jørgensen, Marit E; Vistisen, Dorte

    2015-01-01

    metabolism in a population at high risk of type 2 diabetes. METHODS: A cross-sectional analysis of 1342 participants of the ADDITION-PRO study. We measured visceral adipose tissue and subcutaneous adipose tissue with ultrasonography, anthropometrics and body fat percentage by bioelectrical impedance. Indices...... standard deviation difference in BMI, visceral adipose tissue, waist circumference, waist/height ratio and body fat percentage corresponded approximately to 0.2mmol/l higher fasting glucose, 0.7mmol/l higher 2-hr glucose, 0.06-0.1% higher HbA1c, 30 % lower HOMA index of insulin sensitivity, 20% lower Gutt...

  19. The Usefulness of Homeostatic Measurement Assessment-Insulin Resistance (HOMA-IR) for Detection of Glucose Intolerance in Thai Women of Reproductive Age with Polycystic Ovary Syndrome.

    Science.gov (United States)

    Wongwananuruk, Thanyarat; Rattanachaiyanont, Manee; Leerasiri, Pichai; Indhavivadhana, Suchada; Techatraisak, Kitirat; Angsuwathana, Surasak; Tanmahasamut, Prasong; Dangrat, Chongdee

    2012-01-01

    Objectives. To study the cut-off point of Homeostatic Measurement Assessment-Insulin Resistance (HOMA-IR) as a screening test for detection of glucose intolerance in Thai women with polycystic ovary syndrome (PCOS). Study Design. Cross-sectional study. Setting. Department of Obstetrics and Gynecology, Faculty of Medicine Siriraj Hospital. Subject. Two hundred and fifty Thai PCOS women who attended the Gynecologic Endocrinology Unit, during May 2007 to January 2009. Materials and Methods. The paitents were interviewed and examined for weight, height, waist circumference, and blood pressure. Venous blood samples were drawn twice, one at 12-hour fasting and the other at 2 hours after glucose loading. Results. The prevalence of glucose intolerance in Thai PCOS women was 20.0%. The mean of HOMA-IR was 3.53  ±  7.7. Area under an ROC curve for HOMA-IR for detecting glucose intolerance was 0.82. Using the cut-off value of HOMA-IR >2.0, there was sensitivity at 84.0%, specificity at 61.0%, positive predictive value at 35.0%, negative predictive value at 93.8%, and accuracy at 65.6%. Conclusion. HOMA-IR >2.0 was used for screening test for glucose intolerance in Thai PCOS women. If the result was positive, a specific test should be done to prove the diagnosis.

  20. The Usefulness of Homeostatic Measurement Assessment-Insulin Resistance (HOMA-IR for Detection of Glucose Intolerance in Thai Women of Reproductive Age with Polycystic Ovary Syndrome

    Directory of Open Access Journals (Sweden)

    Thanyarat Wongwananuruk

    2012-01-01

    Full Text Available Objectives. To study the cut-off point of Homeostatic Measurement Assessment-Insulin Resistance (HOMA-IR as a screening test for detection of glucose intolerance in Thai women with polycystic ovary syndrome (PCOS. Study Design. Cross-sectional study. Setting. Department of Obstetrics and Gynecology, Faculty of Medicine Siriraj Hospital. Subject. Two hundred and fifty Thai PCOS women who attended the Gynecologic Endocrinology Unit, during May 2007 to January 2009. Materials and Methods. The paitents were interviewed and examined for weight, height, waist circumference, and blood pressure. Venous blood samples were drawn twice, one at 12-hour fasting and the other at 2 hours after glucose loading. Results. The prevalence of glucose intolerance in Thai PCOS women was 20.0%. The mean of HOMA-IR was 3.53  ±  7.7. Area under an ROC curve for HOMA-IR for detecting glucose intolerance was 0.82. Using the cut-off value of HOMA-IR >2.0, there was sensitivity at 84.0%, specificity at 61.0%, positive predictive value at 35.0%, negative predictive value at 93.8%, and accuracy at 65.6%. Conclusion. HOMA-IR >2.0 was used for screening test for glucose intolerance in Thai PCOS women. If the result was positive, a specific test should be done to prove the diagnosis.

  1. Follow-up duration influences the relative importance of OGTT and optimal timing of glucose measurements for predicting future type 2 diabetes

    DEFF Research Database (Denmark)

    Nielsen, Mette Lundgren; Pareek, Manan; Leósdóttir, Margrét

    2016-01-01

    was recorded using registries. The performance of OGTT added to a clinical prediction model (age, body mass index (BMI), diastolic blood pressure, fasting BG, triglycerides, and family history of diabetes) was assessed using Harrell's concordance index (C-index) and integrated discrimination improvement (IDI......OBJECTIVE: To examine the impact of follow-up duration on the incremental prognostic yield of a baseline oral glucose tolerance test (OGTT) for predicting type 2 diabetes and to assess the discrimination ability of blood glucose (BG) obtained at different time points during OGTT. DESIGN......: A prospective, population-based cohort study (Malmö Preventive Project) with inclusion of subjects from 1974 to 1992. METHODS: A total of 5256 men without diabetes, who had BG measured at 0, 20, 40, 60, 90, and 120 min during OGTT (30 g/m2 glucose), were followed for 30 years. Incident type 2 diabetes...

  2. Calibration of the DLP-SC-3300-02 probe

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Breinbjerg, Olav

    This report douments the calibration measurement of the DLP-SC-3300-02 dual-linearly polarized near-field probe. The measurement comprises radiation pattern, diretivity, gain, spetra of spherial wave coefients, polarization charateristis, and complex channel balance at 41 frequencies, as well...

  3. Roberts-SC phocomelia syndrome.

    Science.gov (United States)

    Maheshwari, A; Kumar, P; Dutta, S; Narang, A

    2001-06-01

    A severely growth retarded baby was born at 38 weeks gestation. He had multiple craniofacial anomalies, microbrachycephaly, phocomelia in the upper limbs and renal cysts visible on ultrasound. He died of recurrent apneas. The autopsy showed left sided multicystic dysplastic kidney and absence of one testis. Cytogenetic studies did not reveal any abnormality. The phenotypic features match those described in the Roberts-SC phocomelia syndrome. A literature review revealed that 50% of these patients have chromosomal defects and antenatal detection is possible on ultrasound and by chromosome analysis of the amniocytes.

  4. [The research of near-infrared blood glucose measurement using particle swarm optimization and artificial neural network].

    Science.gov (United States)

    Dai, Juan; Ji, Zhong; Du, Yubao

    2017-08-01

    Existing near-infrared non-invasive blood glucose detection modelings mostly detect multi-spectral signals with different wavelength, which is not conducive to the popularization of non-invasive glucose meter at home and does not consider the physiological glucose dynamics of individuals. In order to solve these problems, this study presented a non-invasive blood glucose detection model combining particle swarm optimization (PSO) and artificial neural network (ANN) by using the 1 550 nm near-infrared absorbance as the independent variable and the concentration of blood glucose as the dependent variable, named as PSO-2ANN. The PSO-2ANN model was based on two sub-modules of neural networks with certain structures and arguments, and was built up after optimizing the weight coefficients of the two networks by particle swarm optimization. The results of 10 volunteers were predicted by PSO-2ANN. It was indicated that the relative error of 9 volunteers was less than 20%; 98.28% of the predictions of blood glucose by PSO-2ANN were distributed in the regions A and B of Clarke error grid, which confirmed that PSO-2ANN could offer higher prediction accuracy and better robustness by comparison with ANN. Additionally, even the physiological glucose dynamics of individuals may be different due to the influence of environment, temper, mental state and so on, PSO-2ANN can correct this difference only by adjusting one argument. The PSO-2ANN model provided us a new prospect to overcome individual differences in blood glucose prediction.

  5. Creep properties and precipitate evolution in Al-Li alloys microalloyed with Sc and Yb

    Energy Technology Data Exchange (ETDEWEB)

    Krug, Matthew E. [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Drive, Evanston, IL 60208 (United States); Seidman, David N. [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Drive, Evanston, IL 60208 (United States); Northwestern Center for Atom Probe Tomography, Northwestern University, 2220 Campus Drive, Evanston, IL 60208 (United States); Dunand, David C., E-mail: dunand@northwestern.edu [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Drive, Evanston, IL 60208 (United States)

    2012-07-30

    Highlights: Black-Right-Pointing-Pointer We examine the creep behavior of Al-alloys with Li and rare earth element additions. Black-Right-Pointing-Pointer These alloys exhibit threshold stresses below which no measurable creep occurs. Black-Right-Pointing-Pointer Larger precipitate size and lattice parameter mismatch increase creep resistance. Black-Right-Pointing-Pointer A simple parameter describes the threshold stress behavior in ternary Al-Sc-X alloys. Black-Right-Pointing-Pointer The findings are explained by a recent model of dislocation-precipitate interactions. - Abstract: A dilute Al-Sc alloy (Al-0.12 Sc, at.%, Al-Sc), its counterpart with a Li addition (Al-2.9 Li-0.11 Sc, at.%, Al-Li-Sc), as well as a quaternary alloy (Al-5.53 Li-0.048 Sc-0.009 Yb, at.%, Al-Li-Sc-Yb) were isothermally aged at 325 Degree-Sign C, and in some cases isochronally aged to 450 Degree-Sign C. As the {alpha} Prime -Al{sub 3}(Li,Sc) and Al{sub 3}(Li,Sc,Yb) precipitates, with L1{sub 2} structure, coarsen in the two Li-containing alloys, their Li and Yb concentrations decrease and their Sc concentration increases. A significant interfacial excess of Li also segregates at the {alpha}-Al matrix/{alpha} Prime -Al{sub 3}Sc(Li,Sc,Yb) precipitate interface: 5.99 {+-} 0.05 atoms nm{sup -2} in Al-Li-Sc and 13.2 {+-} 0.4 atoms nm{sup -2} in Al-Li-Sc-Yb after aging isochronally to 450 Degree-Sign C. During compression creep at 300 Degree-Sign C, the aged alloys exhibit threshold stresses between 8 and 22 MPa. A recent threshold stress model based on elastic interactions between dislocations and precipitates predicts correctly that Li additions in the Al-Li-Sc alloy reduce the threshold stress, while Yb in the Al-Li-Sc-Yb alloy increases it. The model is also in agreement with the threshold stresses of all Al-Sc-X alloys published to date.

  6. Polymorphous GdScO3 as high permittivity dielectric

    International Nuclear Information System (INIS)

    Schäfer, A.; Rahmanizadeh, K.; Bihlmayer, G.; Luysberg, M.; Wendt, F.; Besmehn, A.; Fox, A.

    2015-01-01

    Four different polymorphs of GdScO 3 are assessed theoretically and experimentally with respect to their suitability as a dielectric. The calculations carried out by density functional theory reveal lattice constants, band gaps and the energies of formation of three crystal phases. Experimentally all three crystal phases and the amorphous phase can be realized as thin films by pulsed laser deposition using various growth templates. Their respective crystal structures are confirmed by X-ray diffraction and transmission electron microscopy reflecting the calculated lattice constants. X-ray photoelectron spectroscopy unveils the band gaps of the different polymorphs of GdScO 3 which are above 5 eV for all films demonstrating good insulating properties. From capacitance voltage measurements, high permittivities of up to 27 for hexagonal GdScO 3 are deduced. - Highlights: • Different epitaxial polymorph phases of GdScO 3 were grown by pulsed laser deposition. • The cubic phase of GdScO 3 is reported for the first time. • All phases are proven to be useful for the use in silicon based and III–V based microelectronic devices.

  7. Piezoelectric coefficients and spontaneous polarization of ScAlN

    International Nuclear Information System (INIS)

    Caro, Miguel A; Laurila, Tomi; Zhang, Siyuan; Moram, Michelle A; Riekkinen, Tommi; Ylilammi, Markku; Molarius, Jyrki; Lopez-Acevedo, Olga

    2015-01-01

    We present a computational study of spontaneous polarization and piezoelectricity in Sc x Al 1−x N alloys in the compositional range from x = 0 to x = 0.5, obtained in the context of density functional theory and the Berry-phase theory of electric polarization using large periodic supercells. We report composition-dependent values of piezoelectric coefficients e ij , piezoelectric moduli d ij and elastic constants C ij . The theoretical findings are complemented with experimental measurement of e 33 for a series of sputtered ScAlN films carried out with a piezoelectric resonator. The rapid increase with Sc content of the piezoelectric response reported in previous studies is confirmed for the available data. A detailed description of the full methodology required to calculate the piezoelectric properties of ScAlN, with application to other complex alloys, is presented. In particular, we find that the large amount of internal strain present in ScAlN and its intricate relation with electric polarization make configurational sampling and the use of large supercells at different compositions necessary in order to accurately derive the piezoelectric response of the material. (paper)

  8. The colours of Hubble Sc galaxy nuclei

    International Nuclear Information System (INIS)

    Iskudaryan, S.G.

    1975-01-01

    The colorimetric data on the nuclei of the Sc galaxies are given. Comparison of the following parameters: color of a nucleus, integral color of a galaxy, Byurakan class, and spectral type of normal spirals gives the possibility to conclude: (1) The colors of the nuclei of the Sc galaxies have a high dispersion in its values. In all Byurakan classes the galaxies with intensely red and blue nuclei occur; (2) Some Sc galaxies exhibit a discrepancy between the spectral and morphological types. The results of colorimetry of nuclei indicate that almost all such Sc galaxies have intensely red nuclei which, naturally, provide for these late spectral types. It can be assumed that the intensely red color of the nuclei of such Sc galaxies is a result of a new type of activity of these nuclei; and (3) some Sc galaxies show the characteristics of the Markarian objects

  9. Emission ability of La-Sc-Mo cathode

    International Nuclear Information System (INIS)

    Yang Jiancan; Nie Zuoren; Xi Xiaoli; Wang Yiman

    2004-01-01

    In this paper La-Sc-Mo cathode has been prepared and its electron emission ability was measured. This type of cathode shows good electron emission performance that the saturated current density is 6.74 A cm -1 and the work function is about 2.59 eV at 1300 deg. C, which is much lower than thoriated tungsten cathode (Th-W). So it is a potential cathode to replace the Th-W cathode with radioactive pollution. Surface analysis shows that good emission ability due to the 20 nm surplus La layer and the element Sc may do good to the La diffusion to the surface

  10. Model of Dees and Rotco for the 600 MeV SC

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The accelerating frequency of the 600 MeV Synchro-Cyclotron (SC) was modulated by the varying capacity of a rotating condenser ("Rotco", the most delicate component of the SC). A 1/5-scale model, dating from the design-period of the SC, was used to study improvements to the SC RF-system, and also the acceleration of ions, first Helium and, at the time of this picture, Carbon. In the middle of the picture is the case containing the Dees. To the left, at the wide end of the cone, a rotco. Reinhold Hohbach is busy with measurements. See also 7805235 (Annual Report 1978, p.110).

  11. Transport of one SC coil through the village of Meyrin

    CERN Multimedia

    1956-01-01

    In 1952, before CERN was officially founded, two accelerator projects were launched: one for an innovative accelerator to operate at an energy level unequalled at the time, the other for a more standard machine, a Synchro-Cyclotron (SC) to operate at 600 MeV. Design work on the SC was started in 1952 and carried out by teams scattered throughout Europe. Once construction began in 1954, CERN had to arrange road transport for the first of what has since been a long series of spectacular component deliveries, such as those of the machine's two magnetic coils each weighing 60 tonnes and measuring 7.2 metres in diameter. Above, one of them is seen passing through the village of Meyrin. The SC was commissioned in 1957 and was operational for 34 years!

  12. Measurements of islet function and glucose metabolism with the dipeptidyl peptidase 4 inhibitor vildagliptin in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Azuma, Koichiro; Rádiková, Zofia; Mancino, Juliet

    2007-01-01

    OBJECTIVE: Pharmacological inhibition with the dipeptidyl peptidase 4 (DPP-4) inhibitor vildagliptin prolongs the action of endogenously secreted incretin hormones leading to improved glycemic control in patients with type 2 diabetes mellitus (T2DM). We undertook a double-blinded, randomized......-order, crossover study to examine the vildagliptin mechanisms of action on islet function and glucose utilization. Research DESIGN AND METHODS: Participants with T2DM (n = 16) who had a baseline hemoglobin A(1c) of 7.1 +/- 0.2% completed a crossover study with 6 wk of treatment with vildagliptin and 6 wk...... with placebo. At the completion of each arm, participants had a study of postprandial metabolism and a two-step glucose clamp performed at 20 and 80 mU/min x m(2) insulin infusions. RESULTS: Vildagliptin increased postprandial glucagon-like peptide-1 and glucose-dependent insulinotropic polypeptide by 3- and 2...

  13. The impact of a low glycaemic index (GI) diet on simultaneous measurements of blood glucose and fat oxidation: A whole body calorimetric study.

    Science.gov (United States)

    Kaur, Bhupinder; Quek Yu Chin, Rina; Camps, Stefan; Henry, Christiani Jeyakumar

    2016-06-01

    Low glycaemic index (GI) foods are known to minimize large fluctuations in blood glucose levels and have been suggested to increase fat oxidation. The objective of this study was to simultaneously investigate glucose excursion and substrate oxidation in a whole body calorimetre when Chinese male subjects were provided a low or high GI meal. In a randomized, controlled crossover non blind design, 12 healthy Chinese male adults (BMI 21.8 ± 1.3 kgm -2 ) attended two sessions consisting of either four low or high glycaemic meals (LGI vs HGI). Breakfast, lunch and snack were consumed in a whole body calorimetre while dinner was consumed at home. Daily changes in glycaemic response (GR) and postprandial GR responses were measured using a continuous glucose monitoring system. The GR was further calculated to obtain the incremental area under the curve (iAUC) for glucose concentrations. Glycaemic variability was calculated as mean amplitude of glycaemic excursion (MAGE). Substrate oxidation was calculated by measuring respiratory quotient and urine nitrogen excretion. After LGI meals in the whole body calorimetre, iAUC for glucose (P = 0.008) was lower compared to the HGI session. The HGI treatment produced a significantly greater MAGE than the LGI treatment over the 24 hour period (P fat oxidation and lower carbohydrate oxidation were observed following breakfast and lunch when comparing LGI to HGI (P fat oxidation over carbohydrate oxidation when compared to HGI mixed meals. The consumption of low GI meals may be a strategic approach in improving overall glycaemia and increasing fat oxidation in Asians consuming a high carbohydrate diet.

  14. Measurement of regional cerebral metabolic rate for glucose in the human subject with (F-18)-2-deoxy-2-fluoro-d-glucose and emission computed tomography: validation of the method

    International Nuclear Information System (INIS)

    Phelps, M.E.; Huang, S.C.; Hoffman, E.J.; Selin, C.; Kuhl, D.E.

    1977-01-01

    Tracer techniques and models of in vitro quantitative autoradiography and tissue counting for the measure of regional metabolic rates (rMR) are combined with emission computed tomography (ECT). This approach, Physiologic Tomography (PT), provides atraumatic and analytical measurements of rMR. PT is exemplified with the regional measurement of the cerebral metabolic rate for glucose (CMRGlu) in man with ( 18 F)-2-deoxy-2-fluoro-D-glucose (FDG) and positron ECT. Our model incorporates a k 4 * mediated hydrolysis of FDG-6-PO 4 to FDG which then competes with phosphorylation (k 3 *) of FDG back to FDG-6-PO 4 and reverse transport (k 2 *) back to blood. Although small, k 4 * is found to be significant. The ECAT positron tomograph was used to measure the rate constants (k 1 *→k 4 *), lumped constant (LC), stability, and reproducibility of the model in man. Since these parameters have not been measured for FDG in any species, comparisons are made to values for DG in rat and monkey. Compartmental concentrations of FDG and FDG-6-PO 4 were determined and show that cerebral FDG-6-PO 4 steadily accumulates for about 100 mins, plateaus and then slowly decreases due to hydrolysis. Cerebral blood FDG concentration was determined to be a minor contribution to tissue activity after 10 min. Regional CMRGlu measurements are reproducible to +- 5.5% over 5 hrs. PT allows the in vivo study ofregional biochemistry and physiology in normal and pathophysiologic states in man with a unique and fundamental capability

  15. Glucose allostasis

    DEFF Research Database (Denmark)

    Stumvoll, Michael; Tataranni, P Antonio; Stefan, Norbert

    2003-01-01

    individuals with normal glucose tolerance, normoglycemia can always be maintained by compensatorily increasing AIR in response to decreasing M (and vice versa). This has been mathematically described by the hyperbolic relationship between AIR and M and referred to as glucose homeostasis, with glucose......In many organisms, normoglycemia is achieved by a tight coupling of nutrient-stimulated insulin secretion in the pancreatic beta-cell (acute insulin response [AIR]) and the metabolic action of insulin to stimulate glucose disposal (insulin action [M]). It is widely accepted that in healthy...... concentration assumed to remain constant along the hyperbola. Conceivably, glucose is one of the signals stimulating AIR in response to decreasing M. Hypothetically, as with any normally functioning feed-forward system, AIR should not fully compensate for worsening M, since this would remove the stimulus...

  16. Development of a photon-cell interactive monte carlo simulation for non-invasive measurement of blood glucose level by Raman spectroscopy.

    Science.gov (United States)

    Sakota, Daisuke; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu

    2015-01-01

    Turbidity variation is one of the major limitations in Raman spectroscopy for quantifying blood components, such as glucose, non-invasively. To overcome this limitation, we have developed a Raman scattering simulation using a photon-cell interactive Monte Carlo (pciMC) model that tracks photon migration in both the extra- and intracellular spaces without relying on the macroscopic scattering phase function and anisotropy factor. The interaction of photons at the plasma-cell boundary of randomly oriented three-dimensionally biconcave red blood cells (RBCs) is modeled using geometric optics. The validity of the developed pciMCRaman was investigated by comparing simulation and experimental results of Raman spectroscopy of glucose level in a bovine blood sample. The scattering of the excitation laser at a wavelength of 785 nm was simulated considering the changes in the refractive index of the extracellular solution. Based on the excitation laser photon distribution within the blood, the Raman photon derived from the hemoglobin and glucose molecule at the Raman shift of 1140 cm(-1) = 862 nm was generated, and the photons reaching the detection area were counted. The simulation and experimental results showed good correlation. It is speculated that pciMCRaman can provide information about the ability and limitations of the measurement of blood glucose level.

  17. Fasting capillary blood glucose: an appropriate measurement in screening for diabetes and pre-diabetes in low-resource rural settings.

    Science.gov (United States)

    Zhao, X; Zhao, W; Zhang, H; Li, J; Shu, Y; Li, S; Cai, L; Zhou, J; Li, Y; Hu, R

    2013-01-01

    To evaluate the efficiency of fasting capillary blood glucose (FCG) measurement as compared with fasting venous plasma glucose (FPG) measurement in screening diabetes and pre-diabetes in low-resource rural settings. In 2010, 993 participants were randomly selected from 9 villages in Yunnan province using cluster sampling method. Samples for FCG and FPG test were obtained after demographics and physical examination. The oral glucose tolerance test was performed in parallel as gold standard for diagnosis. Diagnostic capacities of the FCG measurement in predicting undiagnosed diabetes and pre-diabetes were assessed. The performance of FCG and FPG tests was compared. Fifty-seven individuals with undiagnosed diabetes and 145 subjects with pre-diabetes were detected. The concordance between FCG and FPG levels was high (r = 0.75, p curve (AUC) for FCG test in predicting diabetes was 0.88 [95% confidence interval (CI) 0.82-0.93] with the optimal cutoff value of 5.65 mmol/l, sensitivity of 84.2%, and specificity of 79.3%. The corresponding values in FPG tests were 0.92 (95% CI 0.88-0.97) (AUC), 6.51 mmol/l (optimal cutoff point), 82.5% (sensitivity) and 98.3% (specificity), respectively. No significant difference was found in the AUC for the two screening strategies. FCG measurement is considered to be a convenient, practicable screening method in low-resource rural communities with acceptable test properties.

  18. Optimized methods to measure acetoacetate, 3-hydroxybutyrate, glycerol, alanine, pyruvate, lactate and glucose in human blood using a centrifugal analyser with a fluorimetric attachment.

    Science.gov (United States)

    Stappenbeck, R; Hodson, A W; Skillen, A W; Agius, L; Alberti, K G

    1990-01-01

    Optimized methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, D-3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood using the Cobas Bio centrifugal analyser. Glucose and lactate are measured using the photometric mode and other metabolites using the fluorimetric mode. The intra-assay coefficients of variation ranged from 0.7 to 4.1%, except with very low levels of pyruvate and acetoacetate where the coefficients of variation were 7.1 and 12% respectively. All seven metabolites can be measured in a perchloric acid extract of 20 mul of blood. The methods have been optimized with regard to variation in the perchloric acid content of the samples. These variations arise from the method of sample preparation used to minimize changes occurring in metabolite concentration after venepuncture.

  19. Measurements of urea and glucose in aqueous solutions with dual-beam near-infrared Fourier-transform spectroscopy

    DEFF Research Database (Denmark)

    Jensen, P.S.; Bak, J.

    2002-01-01

    of these two modes of operation. The concentrations of aqueous solutions of urea and glucose in the ranges 0-40 mg/dL and 0-250 mg/dL, respectively, were determined by principal component regression using both modes. The dual-beam technique eliminated instrumental variations present in the single...

  20. Thalamic glucose metabolism in temporal lobe epilepsy measured with 18F-FDG positron emission tomography (PET)

    NARCIS (Netherlands)

    Khan, N; Leenders, KL; Hajek, M; Maguire, P; Missimer, J; Wieser, HG

    1997-01-01

    Thalamic glucose metabolism has been studied in 24 patients suffering from temporal lobe epilepsy (TLE) using interictal F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET). A total of 17 patients had a unilateral TL seizure onset, 11 of these patients had a mesial temporal lobe

  1. 46 CFR 7.70 - Folly Island, SC to Hilton Head Island, SC.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Folly Island, SC to Hilton Head Island, SC. 7.70 Section... BOUNDARY LINES Atlantic Coast § 7.70 Folly Island, SC to Hilton Head Island, SC. (a) A line drawn from the...′ W. (Port Royal Sound Lighted Whistle Buoy “2PR”); thence to the easternmost extremity of Hilton Head...

  2. Addressing glucose sensitivity measured by F-18 FDG PET in lung cancers for radiation treatment planning and monitoring

    International Nuclear Information System (INIS)

    Wong, Ching-yee Oliver; Thie, Joseph; Gaskill, Marianne; Kestin, Larry; Yan Di; Cheng, Vincent; Nagle, Conrad

    2006-01-01

    Purpose: To address glucose sensitivity in lung cancers before and after radiation treatment (Tx). Methods and Materials: Twelve patients were each studied with two pre-Tx positron emission tomography (PET) scans and 3 patients each with one post-Tx PET scan, with glucose concentration [Glc] and maximum standard uptake value (SUV) recorded. The pre-Tx glucose sensitivity, g from SUV 1 /SUV 2 = {[Glc] 1 /[Glc] 2 } g and Tx index, τ from SUV post-Tx /SUV pre-Tx = {[Glc] post-Tx /[Glc] pre-Tx } τ was calculated by linear regression. Pre-Tx SUVs were corrected to post-Tx Glc with g (SUV' pre-Tx ) for a pure Tx effect, R ln(SUV post-Tx /SUV' pre-Tx ). Results: There were no significant differences in SUV but [Glc] were different (96.4 ± 10.9 vs. 88.3 ± 10.5, p = 0.015) between two pre-Tx PET scans. Linear regression yielded g -0.79 and τ = -1.78 to -2.41 (p < 0.0005 in all). The %ΔSUV after Tx for 3 patients without vs. with g correction were different by -12%, 0%, and + 7%, suggesting varying effects from glucose. R values were also different and mean R (-0.81 ± 0.38) was significantly different from zero (p = 0.03), consistent with successful Tx as confirmed by clinico-radiologic follow-up. Conclusions: The extra dimension of glucose sensitivity, g besides SUV incorporated in the combined Tx-derived τ may be a useful global Tx evaluation index even with differing [Glc

  3. Association of glucose homeostasis measures with heart rate variability among Hispanic/Latino adults without diabetes: the Hispanic Community Health Study/Study of Latinos (HCHS/SOL).

    Science.gov (United States)

    Meyer, Michelle L; Gotman, Nathan M; Soliman, Elsayed Z; Whitsel, Eric A; Arens, Raanan; Cai, Jianwen; Daviglus, Martha L; Denes, Pablo; González, Hector M; Moreiras, Juan; Talavera, Gregory A; Heiss, Gerardo

    2016-03-16

    Reduced heart rate variability (HRV), a measure of cardiac autonomic function, is associated with an increased risk of cardiovascular disease (CVD) and mortality. Glucose homeostasis measures are associated with reduced cardiac autonomic function among those with diabetes, but inconsistent associations have been reported among those without diabetes. This study aimed to examine the association of glucose homeostasis measures with cardiac autonomic function among diverse Hispanic/Latino adults without diabetes. The Hispanic community Health Study/Study of Latinos (HCHS/SOL; 2008-2011) used two-stage area probability sampling of households to enroll 16,415 self-identified Hispanics/Latinos aged 18-74 years from four USA communities. Resting, standard 12-lead electrocardiogram recordings were used to estimate the following ultrashort-term measures of HRV: RR interval (RR), standard deviation of all normal to normal RR (SDNN) and root mean square of successive differences in RR intervals (RMSSD). Multivariable regression analysis was used to estimate associations between glucose homeostasis measures with HRV using data from 11,994 adults without diabetes (mean age 39 years; 52 % women). Higher fasting glucose was associated with lower RR, SDNN, and RMSSD. Fasting insulin and the homeostasis model assessment of insulin resistance was negatively associated with RR, SDNN, and RMSSD, and the association was stronger among men compared with women. RMSSD was, on average, 26 % lower in men with higher fasting insulin and 29 % lower in men with lower insulin resistance; for women, the corresponding estimates were smaller at 4 and 9 %, respectively. Higher glycated hemoglobin was associated with lower RR, SDNN, and RMSSD in those with abdominal adiposity, defined by sex-specific cut-points for waist circumference, after adjusting for demographics and medication use. There were no associations between glycated hemoglobin and HRV measures among those without abdominal adiposity

  4. Radiation Protection Section (SC/SL/RP)

    CERN Document Server

    2006-01-01

    We should like to inform you that the Radiation Protection Section (SC/SL/RP) located on the Prévessin site has moved from Building 865 (ground floor) to new premises in Wing A of Building 892 (second floor). Telephone numbers remain the same. SC/SL/RP section

  5. In vivo evaluation of glucose permeability of an immunoisolation device intended for islet transplantation: a novel application of the microdialysis technique.

    Science.gov (United States)

    Rafael, E; Wernerson, A; Arner, P; Wu, G S; Tibell, A

    1999-01-01

    Immunoisolation devices consist of semipermeable membranes chosen to protect the islets from the immune system but still allow sufficient passage of nutrients, oxygen, and the therapeutic products, insulin. The exchange between the device and the microcirculation will influence the survival of the graft as well as the metabolic efficacy of the islet implant. Glucose is the important trigger factor for insulin secretion. In this study, we evaluate the in vivo glucose permeability of the Theracyte immunoisolation device at various times after implantation. Empty devices were implanted s.c. in rats. The glucose kinetics in the device was compared to that in the SC tissue during i.v. glucose tolerance tests (IVGTTs), using the microdialysis technique. In rats studied on day 1, or 1, 2, and 4 weeks after implantation, the peak glucose levels (Cmax) were significantly lower, the times-to-peak (TTP) were significantly longer, and the areas under the curve during the first 40 min (AUC(0-40)) were significantly smaller in the device than in the SC fat. However, at 3 months all parameters improved and Cmax, TTP, and AUC(0-40) in the device did not differ significantly from those measured in the SC fat. Thus, during the first 4 weeks the device constitutes a significant diffusion barrier, but at 3 months the exchange between the lumen of devices and the blood stream improves. Our data indicate that implantation of the device several months before transplantation of the cellular graft would improve the exchange across the membrane during the early posttransplant period. This should have positive effects on graft survival and function. We also suggest that microdialysis is a useful tool for evaluating the in vivo performance of macroencapsulation devices.

  6. Clinical chemistry measurements with commercially available test slides on a smartphone platform: Colorimetric determination of glucose and urea.

    Science.gov (United States)

    Wu, Yuanyuan; Boonloed, Anukul; Sleszynski, Neal; Koesdjojo, Myra; Armstrong, Chadd; Bracha, Shay; Remcho, Vincent T

    2015-08-25

    Rapidly increasing healthcare costs in economically advantaged countries are currently unsustainable, while in many developing nations, even 50-year-old technologies are too expensive to implement. New and unconventional technologies are being explored as solutions to this problem. In this study, we examined the use of a smartphone as the detection platform for 2 well-developed, relatively inexpensive, commercially available clinical chemistry assays as a model for rapid and inexpensive clinical diagnostic testing. An Apple iPhone 4 camera phone equipped with a color analysis application (ColorAssist) was combined with Vitros® glucose and urea colorimetric assays. Color images of assay slides at various concentrations of glucose or urea were collected with the iPhone 4 and quantitated in three different spectral ranges (red/green/blue or RGB) using the ColorAssist app. When the diffuse reflectance data was converted into absorbance, it was possible to quantitate glucose or blood urea nitrogen (BUN) over their clinically important concentration ranges (30-515mg/dl for glucose or 2-190mg/dl for BUN), with good linearity (R(2)=0.9994 or 0.9996, respectively [n=5]). Data collected using the iPhone 4 and canine serum samples were in agreement with results from the instrumental "gold standard" (Beckman Coulter AU480 Chemistry System) (R(2)=0.9966 and slope=1.0001 for glucose; R(2)=0.9958 and slope=0.9454 for BUN). Glucose determinations of serum samples made using this smartphone method were as accurate as or more accurate than a commercial colorimetric dry slide analyzer (Heska® Element DC Chemistry Analyzer, Loveland, CO) and 2 glucometers: ReliOn® Ultima (Abbott Diabetes Care Inc) and Presto® (AgaMatrix Inc.H). BUN determinations made using the smartphone approach were comparable in accuracy to the Heska instrument. This demonstration shows that smartphones have the potential to be used as simple, effective colorimetric detectors for quantitative diagnostic tests

  7. Triglyceride glucose index as a surrogate measure of insulin sensitivity in obese adolescents with normoglycemia, prediabetes, and type 2 diabetes mellitus: comparison with the hyperinsulinemic-euglycemic clamp.

    Science.gov (United States)

    Mohd Nor, Noor Shafina; Lee, SoJung; Bacha, Fida; Tfayli, Hala; Arslanian, Silva

    2016-09-01

    There is a need for simple surrogate estimates of insulin sensitivity in epidemiological studies of obese youth because the hyperinsulinemic-euglycemic clamp is not feasible on a large scale. (i) To examine the triglyceride glucose (TyG) index (Ln[fasting triglycerides (mg/dL) × fasting glucose (mg/dL)/2]) and its relationship to in vivo insulin sensitivity in obese adolescents (OB) along the spectrum of glucose tolerance and (ii) to compare TyG index with triglyceride/high-density lipoprotein TG/HDL and 1/fasting insulin (1/IF ), other surrogates of insulin sensitivity. Cross-sectional data in 225 OB with normal glucose tolerance (NGT), prediabetes (preDM), and type 2 diabetes (T2DM) who had a 3-h hyperinsulinemic-euglycemic clamp and fasting lipid measurement. Insulin-stimulated glucose disposal (Rd) declined significantly across the glycemic groups from OB-NGT to OB-preDM to OB-T2DM with a corresponding increase in TyG index (8.3 ± 0.5, 8.6 ± 0.5, 8.9 ± 0.6, p index to Rd was -0.419 (p index for diagnosis of insulin resistance was 8.52 [receiver operating characteristic-area under the ROC curves (ROC-AUC) 0.750, p index, 1/IF , body mass index (BMI) z-score, glycemic group, and sex. The TyG index affords an easily and widely available simple laboratory method as a surrogate estimate of insulin sensitivity that could be used repeatedly in large-scale observational and/or interventional cohorts of OB. Although not superior to 1/IF , TyG index offers the advantage of having a standardized method of measuring triglyceride and glucose, which is not the case for insulin assays. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Structure and equilibria of Ca 2+-complexes of glucose and sorbitol from multinuclear ( 1H, 13C and 43Ca) NMR measurements supplemented with molecular modelling calculations

    Science.gov (United States)

    Pallagi, A.; Dudás, Cs.; Csendes, Z.; Forgó, P.; Pálinkó, I.; Sipos, P.

    2011-05-01

    Ca 2+-complexation of D-glucose and D-sorbitol have been investigated with the aid of multinuclear ( 1H, 13C and 43Ca) NMR spectroscopy and ab initio quantum chemical calculations. Formation constants of the forming 1:1 complexes have been estimated from one-dimensional 13C NMR spectra obtained at constant ionic strength (1 M NaCl). Binding sites were identified from 2D 1H- 43Ca NMR spectra. 2D NMR measurements and ab initio calculations indicated that Ca 2+ ions were bound in a tridentate manner via the glycosidic OH, the ethereal oxygen in the ring and the OH on the terminal carbon for the α- and β-anomers of glucose and for sorbitol simultaneous binding of four hydroxide moieties (C1, C2, C4 and C6) was suggested.

  9. Sc-W-Si and Sc-W-Ge ternary systems

    International Nuclear Information System (INIS)

    Kotur, B.Ya.; Voznyak, O.M.; Bodak, O.I.

    1989-01-01

    Phase equilibria in Sc-W-Si and Sc-W-Ge ternary systems are investigated at 1070 K. Sc 2+x W 3-x Si 4 ternary compound (0≤x≤1) is determined, its crystal structure (Ce 2 Sc 3 Si 4 structural type), as well as, change of elementary cell parameters and microhardness within homogeneity range are determined. Regularities of component interaction within Sc-M-Si(Ge) (M-Cr, Mo, W) ternary system are determined. Ternary systems with Mo and W are more closer to each other according to the phase equilibria character, than to ternary systems with Cr

  10. The cross section measurement for the reactions of 48,46Ti(n,p) 48,46Sc, 50Ti(n, α)47Ca and 58Ni (n, 2n)57Ni, 58Ni(n,p)58m+gCo

    International Nuclear Information System (INIS)

    Yuan Junqian; Wang Yongchang; Kong Xiangzhong; Yang Jingkang

    1992-01-01

    The cross sections for the 50 Ti(n, α) 47 Ca, 46 Ti(n, p) 46 Sc, 48 Ti(n, p) 48 Sc and 58 Ni(n, 2n) 57 Ni, 58 Ni(n, p) 58m+g Co reactions have been measured by using the activation method relative to the cross sections of the 27 Al(n, α) 24 Na reaction in the neutron energy range of 13.50-14.81 MeV. The neutron energies were determined by the cross section ratios of the 90 Zr(n, 2n) 89m+g Zr and 93 Nb(n, 2n) 92m Nb reactions. The results obtained are compared with the published and to be published data of several authors

  11. Phase relationship in AL-Cu-Sc alloys at 450-500 deg C

    International Nuclear Information System (INIS)

    Kharakterova, M.L.

    1991-01-01

    Al-Cu-Sc alloys containing up to 40% Cu and up to 6% Sc at 450 deg C and 500 deg C are studied using light microscopy, X-ray-spectral microanalysis, X-ray diffraction analysis, scanning electron microscopy, measurement of microhardness and electric resistance. It is determined, that in equilibrium with aluminium solid solution under the given temperature ther are Al 3 Sc, CuAl 2 phases of the respective binary systems and W (ScCu 6.6-4 Al 5.4-8 ) ternary phase. Isothermal cross sections of Al-Cu-Sc system at 450 and 500 deg C are plotted. Microhardness of equilibrium phases is measured. Combined solubility of copper and scandium in aluminium is determined

  12. Study of the hyperfine magnetic field at Ta181 site in the Heusler Co2 Sc Sn, Co2 Sc Ga and Co2 Hf Sn alloys

    International Nuclear Information System (INIS)

    Attili, R.N.

    1992-01-01

    The hyperfine magnetic fields acting on 181 Ta nuclei at the Sc and Hf sites have been measured in Heusler alloys Co 2 Sc Sn and Co 2 Sc Ga and Co 2 Hf Sn using the Time Differential Perturbed γ-γ Angular Correlation (TDPAC) technique. The measurements were carried out using an automatic spectrometer consisting of two Ba F 2 detectors and the conventional electronics. The magnitude of hyperfine magnetic field at 181 Ta was measured for all the alloys. The signs of the were determined in the cases of Co 2 Sc Sn and Co 2 Hf Sn alloys by performing the Perturbed Angular Correlation measurements with an external polarizing magnetic field of ≅ 5 k Gauss. The hyperfine magnetic fields obtained are -187,6± 3,3 and 90,0 ± 2,1 kOe measured at 77 K for Co 2 Sc Sn and Co 2 Sc Ga alloys respectively, and -342,4 ± 10,1 kOe measured at the room temperature for Co 2 Hf Sn alloy. These results are discussed and compared with the hyperfine magnetic field systematics in Co-based Heusler alloy. (author)

  13. Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose

    International Nuclear Information System (INIS)

    Gambhir, S.S.; Schwaiger, M.; Huang, S.C.; Krivokapich, J.; Schelbert, H.R.; Nienaber, C.A.; Phelps, M.E.

    1989-01-01

    To estimate regional myocardial glucose utilization (rMGU) with positron emission tomography (PET) and 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG) in humans, we studied a method which simplifies the experimental procedure and is computationally efficient. This imaging approach uses a blood time-activity curve derived from a region of interest (ROI) drawn over dynamic PET images of the left ventricle (LV), and a Patlak graphic analysis. The spillover of radioactivity from the cardiac chambers to the myocardium is automatically removed by this analysis. Estimates of rMGU were obtained from FDG PET cardiac studies of six normal human subjects. Results from this study indicate that the FDG time-activity curve obtained from the LV ROI matched well with the arterial plasma curve. The rMGU obtained by Patlak graphic analysis was in good agreement with direct curve fitting results (r = 0.90). The average standard error of the estimate of the Patlak rMGU was low (3%). These results demonstrate the practical usefulness of a simplified method for the estimation of rMGU in humans by PET. This approach is noninvasive, computationally fast, and highly suited for developing parametric images of myocardial glucose utilization rate

  14. Precision of glucose measurements in control sera by isotope dilution/mass spectrometry: proposed definitive method compared with a reference method

    International Nuclear Information System (INIS)

    Pelletier, O.; Arratoon, C.

    1987-01-01

    This improved isotope-dilution gas chromatographic/mass spectrometric (GC/MS) method, in which [ 13 C]glucose is the internal standard, meets the requirements of a Definitive Method. In a first study with five reconstituted lyophilized sera, a nested analysis of variance of GC/MS values indicated considerable among-vial variation. The CV for 32 measurements per serum ranged from 0.5 to 0.9%. However, concentration and uncertainty values (mmol/L per gram of serum) assigned to one serum by the NBS Definitive Method (7.56 +/- 0.28) were practically identical to those obtained with the proposed method (7.57 +/- 0.20). In the second study, we used twice more [ 13 C]glucose diluent to assay four serum pools and two lyophilized sera. The CV ranged from 0.26 to 0.5% for the serum pools and from 0.28 to 0.59% for the lyophilized sera. In comparison, results by the hexokinase/glucose-6-phosphate dehydrogenase reference method agreed within acceptable limits with those by the Definitive Method but tended to be slightly higher (up to 3%) for lyophilized serum samples or slightly lower (up to 2.5%) for serum pools

  15. SC-FDMA for mobile communications

    CERN Document Server

    Abd El-Samie, Fathi E

    2013-01-01

    SC-FDMA for Mobile Communications examines Single-Carrier Frequency Division Multiple Access (SC-FDMA). Explaining this rapidly evolving system for mobile communications, it describes its advantages and limitations and outlines possible solutions for addressing its current limitations. The book explores the emerging trend of cooperative communication with SC-FDMA and how it can improve the physical layer security. It considers the design of distributed coding schemes and protocols for wireless relay networks where users cooperate to send their data to the destination. Supplying you with the re

  16. Blood spot-based measures of glucose homeostasis and diabetes prevalence in a nationally representative population of young US adults.

    Science.gov (United States)

    Nguyen, Quynh C; Whitsel, Eric A; Tabor, Joyce W; Cuthbertson, Carmen C; Wener, Mark H; Potter, Alan J; Halpern, Carolyn T; Killeya-Jones, Ley A; Hussey, Jon M; Suchindran, Chirayath; Harris, Kathleen Mullan

    2014-12-01

    We investigated understudied biomarker-based diabetes among young US adults, traditionally characterized by low cardiovascular disease risk. We examined 15,701 participants aged 24 to 32 years at Wave IV of the National Longitudinal Study of Adolescent Health (Add Health, 2008). The study used innovative and relatively noninvasive methods to collect capillary whole blood via finger prick at in-home examinations in all 50 states. Assays of dried blood spots produced reliable and accurate values of HbA1c. Reliability was lower for fasting glucose and lowest for random glucose. Mean (SD) HbA1c was 5.6% (0.8%). More than a quarter (27.4%) had HbA1c-defined prediabetes. HbA1c was highest in the black, non-Hispanic race/ethnic group, inversely associated with education, and more common among the overweight/obese and physically inactive. The prevalence of diabetes defined by previous diagnosis or use of antidiabetic medication was 2.9%. Further incorporating HbA1c and glucose values, the prevalence increased to 6.8%, and among these participants, 38.9% had a previous diagnosis of diabetes (i.e., aware). Among those aware, 37.6% were treated and 64.0% were controlled (i.e., HbA1c young adults faces a historically high risk of diabetes but there is ample opportunity for early detection and intervention. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Human Subcutaneous Tissue Response to Glucose Sensors: Macrophages Accumulation Impact on Sensor Accuracy.

    Science.gov (United States)

    Rigla, Mercedes; Pons, Belén; Rebasa, Pere; Luna, Alexis; Pozo, Francisco Javier; Caixàs, Assumpta; Villaplana, Maria; Subías, David; Bella, Maria Rosa; Combalia, Neus

    2018-04-01

    Subcutaneous (s.c.) glucose sensors have become a key component in type 1 diabetes management. However, their usability is limited by the impact of foreign body response (FBR) on their duration, reliability, and accuracy. Our study gives the first description of human acute and subacute s.c. response to glucose sensors, showing the changes observed in the sensor surface, the inflammatory cells involved in the FBR and their relationship with sensor performance. Twelve obese patients (seven type 2 diabetes) underwent two abdominal biopsies comprising the surrounding area where they had worn two glucose sensors: the first one inserted 7 days before and the second one 24 h before biopsy procedure. Samples were processed and studied to describe tissue changes by two independent pathologists (blind regarding sensor duration). Macrophages quantification was studied by immunohistochemistry methods in the area surrounding the sensor (CD68, CD163). Sensor surface changes were studied by scanning electron microscopy. Seven-day continuous glucose monitoring records were considered inaccurate when mean absolute relative difference was higher than 10%. Pathologists were able to correctly classify all the biopsies regarding sensor duration. Acute response (24 h) was characterized by the presence of neutrophils while macrophages were the main cell involved in subacute inflammation. The number of macrophages around the insertion hole was higher for less accurate sensors compared with those performing more accurately (32.6 ± 14 vs. 10.6 ± 1 cells/0.01 mm 2 ; P sensor-tissue interface is related with decrease in accuracy of the glucose measure.

  18. 33 CFR 80.712 - Morris Island, SC to Hilton Head Island, SC.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Morris Island, SC to Hilton Head..., SC to Hilton Head Island, SC. (a) A line drawn from the easternmost tip of Folley Island to the... easternmost extremity of Hilton Head at latitude 32°13.0′ N. longitude 80°40.1′ W. [CGD 77-118a, 42 FR 35784...

  19. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  20. Process of DC-SC photoinjector

    International Nuclear Information System (INIS)

    Xiang Rong; Zhao Kui; Quan Shengwen; Ding Yuantao; Zhang Baocheng; Lu Xiangyang; Lin Lin; Wang Lifang; Chen Jiaer

    2004-01-01

    The DC-SC photoinjector at Beijing University is designed to provide an electron beam of average current 1 mA with the energy of 2-3 MeV and normalized rms transverse emittance of 3πmm-mrad at an 81.25 MHz repetition rate. The test facility has been completely installed in our lab. In this paper some of the ongoing experimental activities are summarized. First results from the cold test of superconducting cavity have been presented. According to the results, authors have improved the main coupler to repress the multipacting. The beam test of 100 μA on the DC gun has been done, photocathode preparation chamber can produce Cs 2 Te cathodes, and the laser system can provide laser pulse with 266 nm wavelength. The time synchronization between laser and RF power has been achieved by a timing stabilizer. A new method using 'due image pattern' of Cherenkov radiation will be commissioned to measure beam emittance. The next step is under way, to prepare all the equipment for the beam tests. (authors)

  1. Dexamethasone increases glucose cycling, but not glucose production, in healthy subjects

    International Nuclear Information System (INIS)

    Wajngot, A.; Khan, A.; Giacca, A.; Vranic, M.; Efendic, S.

    1990-01-01

    We established that measurement of glucose fluxes through glucose-6-phosphatase (G-6-Pase; hepatic total glucose output, HTGO), glucose cycling (GC), and glucose production (HGP), reveals early diabetogenic changes in liver metabolism. To elucidate the mechanism of the diabetogenic effect of glucocorticoids, we treated eight healthy subjects with oral dexamethasone (DEX; 15 mg over 48 h) and measured HTGO with [2-3H]glucose and HGP with [6-3H]glucose postabsorptively and during a 2-h glucose infusion (11.1 mumol.kg-1.min-1). [2-3H]- minus [6-3H]glucose equals GC. DEX significantly increased plasma glucose, insulin, C peptide, and HTGO, while HGP was unchanged. In controls and DEX, glucose infusion suppressed HTGO (82 vs. 78%) and HGP (87 vs. 91%). DEX increased GC postabsorptively (three-fold) P less than 0.005 and during glucose infusion (P less than 0.05) but decreased metabolic clearance and glucose uptake (Rd), which eventually normalized, however. Because DEX increased HTGO (G-6-Pase) and not HGP (glycogenolysis + gluconeogenesis), we assume that DEX increases HTGO and GC in humans by activating G-6-Pase directly, rather than by expanding the glucose 6-phosphate pool. Hyperglycemia caused by peripheral effects of DEX can also contribute to an increase in GC by activating glucokinase. Therefore, measurement of glucose fluxes through G-6-Pase and GC revealed significant early effects of DEX on hepatic glucose metabolism, which are not yet reflected in HGP

  2. Time-lapse 3-D measurements of a glucose biosensor in multicellular spheroids by light sheet fluorescence microscopy in commercial 96-well plates.

    Science.gov (United States)

    Maioli, Vincent; Chennell, George; Sparks, Hugh; Lana, Tobia; Kumar, Sunil; Carling, David; Sardini, Alessandro; Dunsby, Chris

    2016-11-25

    Light sheet fluorescence microscopy has previously been demonstrated on a commercially available inverted fluorescence microscope frame using the method of oblique plane microscopy (OPM). In this paper, OPM is adapted to allow time-lapse 3-D imaging of 3-D biological cultures in commercially available glass-bottomed 96-well plates using a stage-scanning OPM approach (ssOPM). Time-lapse 3-D imaging of multicellular spheroids expressing a glucose Förster resonance energy transfer (FRET) biosensor is demonstrated in 16 fields of view with image acquisition at 10 minute intervals. As a proof-of-principle, the ssOPM system is also used to acquire a dose response curve with the concentration of glucose in the culture medium being varied across 42 wells of a 96-well plate with the whole acquisition taking 9 min. The 3-D image data enable the FRET ratio to be measured as a function of distance from the surface of the spheroid. Overall, the results demonstrate the capability of the OPM system to measure spatio-temporal changes in FRET ratio in 3-D in multicellular spheroids over time in a multi-well plate format.

  3. No relationship between cerebral blood flow velocity and cerebrovascular reserve capacity and contemporaneously measured glucose and insulin concentrations in diabetes mellitus

    NARCIS (Netherlands)

    Fülesdi, B.; Limburg, M.; Bereczki, D.; Molnár, C.; Michels, R. P.; Leányvári, Z.; Csiba, L.

    1999-01-01

    Blood glucose and insulin concentrations have been reported to influence cerebral hemodynamics. We studied the relationship between actual blood glucose and insulin concentrations and resting cerebral blood flow velocity in the middle cerebral artery and cerebrovascular reserve capacity after

  4. Direct measurement of glucose profiles in immobilized yeast gels with a pH-insensitive micro-electrode under anaerobic conditions

    NARCIS (Netherlands)

    Cronenberg, C.C.H.; Heuvel, van den J.C.; Ottengraf, S.P.P.

    1993-01-01

    A 10 µm glucose sensor was developed based on a glucose oxidase coated Pt-electrode inserted in a capillary shaft. The internal buffer medium effected in a glucose response that was insensitive for the external pH. The sensor was successfully utilized at pH 4 under anaerobic conditions in gel

  5. Measurement of striatal dopamine metabolism with 6-[18F]-fluoro-L-dopa and PET

    International Nuclear Information System (INIS)

    Kuwabara, Y.; Otsuka, M.; Ichiya, Y.; Yoshikai, T.; Fukumura, T.; Masuda, K.; Kato, M.; Taniwaki, T.

    1992-01-01

    Striatal dopamine metabolism was studied with 6-[ 18 F]-fluoro-L-dopa ( 18 F-DOPA) and PET. The subjects were normal controls, and patients with Parkinson's disease (PD), parkinsonism, multiple system atrophy (MSA), progressive supranuclear palsy (PSP), Alzheimer's disease (AD), Huntington's disease (HD) and other cerebral disorders. Cerebral glucose metabolism (CMRGlc) was also measured in these patients. Striatal dopamine metabolism was evaluated by the relative striatal uptake of 18 F-DOPA referring cerebellum (S/C ratio). In normal controls, the S/C ratio was 2.82 ± 0.32 (n = 6, mean ± SD) at 120 min after injection of 18 F-DOPA. The S/C ratio was low in patients with PD, parkinsonism, MSA and PSP compared to the normal controls and thus coincident with the symptoms of parkinsonism due to decrease in striatal dopamine concentration. The decrease in the striatal CMRGlc was also observed in patients with parkinsonism and PSP, and it was preserved in patients with PD, thus representing that more neurons were damaged in patients with parkinsonism and PSP than in patients with PD. A patient with AD having symptoms of parkinsonism also showed a decrease in S/C ratio. In a patient with HD, the striatal CMRGlc sharply decreased, but the S/C ratio was normal. The measurements of striatal dopamine and glucose metabolism with PET may be useful for studying the pathophysiological mechanism in patients with cerebral disorders. (author)

  6. Osmotic load from glucose polymers.

    Science.gov (United States)

    Koo, W W; Poh, D; Leong, M; Tam, Y K; Succop, P; Checkland, E G

    1991-01-01

    Glucose polymer is a carbohydrate source with variable chain lengths of glucose units which may result in variable osmolality. The osmolality of two commercial glucose polymers was measured in reconstituted powder infant formulas, and the change in osmolality of infant milk formulas at the same increases in energy density (67 kcal/dL to 81 and 97 kcal/dL) from the use of additional milk powder or glucose polymers was compared. All samples were prepared from powders (to nearest 0.1 mg), and osmolality was measured by freezing point depression. For both glucose polymers the within-batch variability of the measured osmolality was less than 3.5%, and between-batch variability of the measured osmolality was less than 9.6%. The measured osmolality varies linearly with energy density (p less than 0.001) and was highest in infant formula reconstituted from milk powder alone. However, there exist significant differences in the measured osmolality between different glucose polymer preparations. At high energy densities (greater than or equal to 97 kcal/dL), infant milk formulas prepared with milk powder alone or with the addition of certain glucose polymer preparation may have high osmolality (greater than or equal to 450 mosm/kg) and theoretically predispose the infant to complications of hyperosmotic feeds.

  7. Detection of correct and incorrect measurements in real-time continuous glucose monitoring systems by applying a postprocessing support vector machine.

    Science.gov (United States)

    Leal, Yenny; Gonzalez-Abril, Luis; Lorencio, Carol; Bondia, Jorge; Vehi, Josep

    2013-07-01

    Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a postprocessing strategy for imbalanced datasets. The proposed SVM considers the geometric mean to obtain a more balanced performance between sensitivity and specificity. To test this approach, 23 critically ill patients receiving insulin therapy were monitored over 72 h using an RTCGMS, and a dataset of 537 samples, classified according to International Standards Organization (ISO) criteria (372 correct and 165 incorrect measurements), was obtained. The results obtained were promising for patients with septic shock or with sepsis, for which the proposed system can be considered as reliable. However, this approach cannot be considered suitable for patients without sepsis.

  8. Neuroscience of glucose homeostasis

    NARCIS (Netherlands)

    La Fleur, S E; Fliers, E; Kalsbeek, A

    2014-01-01

    Plasma glucose concentrations are homeostatically regulated and maintained within strict boundaries. Several mechanisms are in place to increase glucose output when glucose levels in the circulation drop as a result of glucose utilization, or to decrease glucose output and increase tissue glucose

  9. An effect of cation functionalization on thermophysical properties of ionic liquids and solubility of glucose in them – Measurements and PC-SAFT calculations

    International Nuclear Information System (INIS)

    Paduszyński, Kamil; Okuniewski, Marcin; Domańska, Urszula

    2016-01-01

    Highlights: • Density, viscosity and DSC thermograms for four ionic liquids were measured. • New data on solubility of glucose in ionic liquids were presented. • An impact of cation functionalization on solubility was established. • Apparent thermodynamic functions of dissolution were determined. • Modeling of the studied systems with PC-SAFT equation of state was performed. - Abstract: This contribution is concerned with thermodynamic investigation on thermophysical properties of four ionic liquids based on dicyanamide anion. The ionic liquids under study differ in substituent attached to imidazolium cation, so that an impact of terminal functional groups on the considered properties is established. Discussion is presented in terms of molecular packing and interactions (polarity, hydrogen bonding) between molecules forming system. Differential scanning calorimetry thermograms, density and viscosity were the investigated properties of pure ionic liquids. Moreover, new data sets on solubility of glucose in ionic liquids are presented. Analysis of the temperature-dependent solubility data by means of modified Van’t Hoff equation is given and apparent thermodynamic functions of dissolution are calculated. Thermodynamic modeling of the (solid + liquid) equilibrium phase diagrams was carried out by means of perturbed-chain statistical associating fluid theory (PC-SAFT). It is evidenced that consistent and accurate thermodynamic description of complex cross-associating {ionic liquid + sugar} systems can be achieved by using simple (but physically grounded) molecular schemes, assuming that two adjustable binary corrections are introduced.

  10. Structure and bonding of ScCN and ScNC: Ground and low-lying states

    International Nuclear Information System (INIS)

    Kalemos, Apostolos; Metropoulos, Aristophanes; Mavridis, Aristides

    2012-01-01

    Graphical abstract: The experimentally unknown systems ScCN and ScNC have been studied through single reference CISD and CCSD(T) methods. A total of 20 = 10 (ScCN) + 10 (ScNC) states were examined. All states are quite ionic whereas ScNC(X ∼3 Δ) is stabler than ScCN(X ∼3 Δ) by ∼5 kcal/mol. Display Omitted Highlights: ► We have studied through ab initio methods the polytopic system Sc[CN]. ► A series of low lying states for both isomeric forms have been examined. ► Around equilibrium the system displays a pronounced Sc + [CN] − ionic character. - Abstract: We have studied the experimentally unknown Sc[CN] molecular system in both its isomeric forms, scandium cyanide (ScCN) and isocyanide (ScNC), through ab initio computations. We report energetics, geometries, harmonic frequencies, and dipole moments for the first 20 Sc[CN] states correlating diabatically to Sc + ( 3 D, 1 D, 3 F) + CN − (X 1 Σ + ). Both isomers have a pronounced ionic character around equilibrium due to the high electron affinity of the CN group and the low ionization energy of the Sc atom. According to our calculations the ScNC isomer (X ∼3 Δ) is stabler than the ScCN(X ∼3 Δ) by ∼5 kcal/mol.

  11. Chronic hypoxia suppresses the CO2 response of solitary complex (SC) neurons from rats.

    Science.gov (United States)

    Nichols, Nicole L; Wilkinson, Katherine A; Powell, Frank L; Dean, Jay B; Putnam, Robert W

    2009-09-30

    We studied the effect of chronic hypobaric hypoxia (CHx; 10-11% O(2)) on the response to hypercapnia (15% CO(2)) of individual solitary complex (SC) neurons from adult rats. We simultaneously measured the intracellular pH and firing rate responses to hypercapnia of SC neurons in superfused medullary slices from control and CHx-adapted adult rats using the blind whole cell patch clamp technique and fluorescence imaging microscopy. We found that CHx caused the percentage of SC neurons inhibited by hypercapnia to significantly increase from about 10% up to about 30%, but did not significantly alter the percentage of SC neurons activated by hypercapnia (50% in control vs. 35% in CHx). Further, the magnitudes of the responses of SC neurons from control rats (chemosensitivity index for activated neurons of 166+/-11% and for inhibited neurons of 45+/-15%) were the same in SC neurons from CHx-adapted rats. This plasticity induced in chemosensitive SC neurons by CHx appears to involve intrinsic changes in neuronal properties since they were the same in synaptic blockade medium.

  12. Heterogeneity in glucose response curves during an oral glucose tolerance test and associated cardiometabolic risk

    DEFF Research Database (Denmark)

    Hulman, Adam; Simmons, Rebecca Kate; Vistisen, Dorte

    2017-01-01

    patterns of plasma glucose change during the oral glucose tolerance test. Cardiometabolic risk factor profiles were compared between the identified groups. Using latent class trajectory analysis, five glucose response curves were identified. Despite similar fasting and 2-h values, glucose peaks and peak......We aimed to examine heterogeneity in glucose response curves during an oral glucose tolerance test with multiple measurements and to compare cardiometabolic risk profiles between identified glucose response curve groups. We analyzed data from 1,267 individuals without diabetes from five studies...... in Denmark, the Netherlands and the USA. Each study included between 5 and 11 measurements at different time points during a 2-h oral glucose tolerance test, resulting in 9,602 plasma glucose measurements. Latent class trajectories with a cubic specification for time were fitted to identify different...

  13. Magnetic dipole moment of the doubly closed-shell plus one proton nucleus $^{49}$Sc

    CERN Multimedia

    Gaulard, C V; Walters, W; Nishimura, K; Muto, S; Bingham, C R

    It is proposed to measure the magnetic moment of $^{49}$Sc by the Nuclear Magnetic Resonance on Oriented Nuclei (NMR-ON) method using the NICOLE on-line nuclear orientation facility. $^{49}$Sc is the neutron rich, doubly closed-shell, nucleus $^{48}$Ca plus one proton. Results will be used to deduce the effective g-factors in the $^{48}$Ca region with reference to nuclear structure and meson exchange current effects.

  14. Extraction mechanism of Sc(III) from sulphuric acid solution by primary amine N1923

    International Nuclear Information System (INIS)

    Le Shaoming; Li Deqian; Ni Jiazan

    1987-01-01

    The extraction mechanism of Sc(III) from sulphuric acid solution by primary amine N 1923 (RNH 2 ) has been investigated by means of slope, isomolar continuous variation and saturation methods. The effect of temperature on the extraction of Sc(III) is observed. The extraction equilibrium constant and thermodynamic functions (ΔH, ΔS and ΔG) are obtained. The IR and NMR of extracted compound are measured

  15. The determination of solubility and diffusion coefficient for solids in liquids by an inverse measurement technique using cylinders of amorphous glucose as a model compound

    International Nuclear Information System (INIS)

    Hu, Chengyao; Huang, Pei

    2011-01-01

    The importance of sugar and sugar-containing materials is well recognized nowadays, owing to their application in industrial processes, particularly in the food, pharmaceutical and cosmetic industries. Because of the large numbers of those compounds involved and the relatively small number of solubility and/or diffusion coefficient data for each compound available, it is highly desirable to measure the solubility and/or diffusion coefficient as efficiently as possible and to be able to improve the accuracy of the methods used. In this work, a new technique was developed for the measurement of the diffusion coefficient of a stationary solid solute in a stagnant solvent which simultaneously measures solubility based on an inverse measurement problem algorithm with the real-time dissolved amount profile as a function of time. This study differs from established techniques in both the experimental method and the data analysis. The experimental method was developed in which the dissolved amount of solid solute in quiescent solvent was investigated using a continuous weighing technique. In the data analysis, the hybrid genetic algorithm is used to minimize an objective function containing a calculated and a measured dissolved amount with time. This is measured on a cylindrical sample of amorphous glucose in methanol or ethanol. The calculated dissolved amount, that is a function of the unknown physical properties of the solid solute in the solvent, is calculated by the solution of the two-dimensional nonlinear inverse natural convection problem. The estimated values of the solubility of amorphous glucose in methanol and ethanol at 293 K were respectively 32.1 g/100 g methanol and 1.48 g/100 g ethanol, in agreement with the literature values, and support the validity of the simultaneously measured diffusion coefficient. These results show the efficiency and the stability of the developed technique to simultaneously estimate the solubility and diffusion coefficient. Also

  16. Photo-acoustic sensor based on an inexpensive piezoelectric film transducer and an amplitude-stabilized single-mode external cavity diode laser for in vitro measurements of glucose concentration

    Science.gov (United States)

    Bayrakli, Ismail; Erdogan, Yasar Kemal

    2018-06-01

    The present paper focuses on development of a compact photo-acoustic sensor using inexpensive components for glucose analysis. An amplitude-stabilized wavelength-tunable single-mode external cavity diode laser operating around 1050 nm was realized and characterized for the use of laser beam as an excitation light source. In the established setup, a fine tuning range of 9 GHz was achieved. The glucose solution was obtained by diluting D-glucose in sterile water. The acoustic signal generated by the optical excitation was detected via a chip piezoelectric film transducer. A detection limit of 50 mM (900 mg/dl) was achieved. The device may be of great interest for its applications in medicine and health monitoring. The sensor is promising for non-invasive in vivo glucose measurements from interstitial fluid.

  17. Blood glucose level reconstruction as a function of transcapillary glucose transport.

    Science.gov (United States)

    Koutny, Tomas

    2014-10-01

    A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Synthesis and Isolation of the Titanium-Scandium Endohedral Fullerenes-Sc2 TiC@Ih -C80 , Sc2 TiC@D5h -C80 and Sc2 TiC2 @Ih -C80 : Metal Size Tuning of the Ti(IV) /Ti(III) Redox Potentials.

    Science.gov (United States)

    Junghans, Katrin; Ghiassi, Kamran B; Samoylova, Nataliya A; Deng, Qingming; Rosenkranz, Marco; Olmstead, Marilyn M; Balch, Alan L; Popov, Alexey A

    2016-09-05

    The formation of endohedral metallofullerenes (EMFs) in an electric arc is reported for the mixed-metal Sc-Ti system utilizing methane as a reactive gas. Comparison of these results with those from the Sc/CH4 and Ti/CH4 systems as well as syntheses without methane revealed a strong mutual influence of all key components on the product distribution. Whereas a methane atmosphere alone suppresses the formation of empty cage fullerenes, the Ti/CH4 system forms mainly empty cage fullerenes. In contrast, the main fullerene products in the Sc/CH4 system are Sc4 C2 @C80 (the most abundant EMF from this synthesis), Sc3 C2 @C80 , isomers of Sc2 C2 @C82 , and the family Sc2 C2 n (2 n=74, 76, 82, 86, 90, etc.), as well as Sc3 CH@C80 . The Sc-Ti/CH4 system produces the mixed-metal Sc2 TiC@C2 n (2 n=68, 78, 80) and Sc2 TiC2 @C2 n (2 n=80) clusterfullerene families. The molecular structures of the new, transition-metal-containing endohedral fullerenes, Sc2 TiC@Ih -C80 , Sc2 TiC@D5h -C80 , and Sc2 TiC2 @Ih -C80 , were characterized by NMR spectroscopy. The structure of Sc2 TiC@Ih -C80 was also determined by single-crystal X-ray diffraction, which demonstrated the presence of a short Ti=C double bond. Both Sc2 TiC- and Sc2 TiC2 -containing clusterfullerenes have Ti-localized LUMOs. Encapsulation of the redox-active Ti ion inside the fullerene cage enables analysis of the cluster-cage strain in the endohedral fullerenes through electrochemical measurements. © 2016 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  19. Laser photoelectron spectrometry of Sc- and Y-

    International Nuclear Information System (INIS)

    Feigerle, C.S.; Herman, Z.; Lineberger, W.C.

    1981-01-01

    The photoelectron spectra of Sc - and Y - have been obtained in a crossed ion- and laser-beam experiment. Analysis of the Sc - spectrum yields two bound terms of 3d4s 2 4p configuration ( 1 D 0 and 3 D 0 ), with EA(Sc) = 0.189 +- 0.020 eV and an excited-state binding energy of 0.042 +- 0.020 eV. Similarly, the (4d5s 2 5p) 1 D 0 ground state of Y - is bound by 0.308 +- 0.012 eV and a (4d5s 2 5p) 3 D 0 excited term is bound by 0.165 +- 0.025 eV. With the determination of the bound electronic configuration of Sc - as 3d4s 2 4p, the order of filling of electron shells of the first transition series negative ions is found to be 4s 2 ep, 3d4s 2 4p, the order of filling of electron shells of the first transition series negative ions is found to be 4s 2 4p, 3d4s 2 4p, followed by 3dsup(k) 4s 2 (k = 3, 4, ..., 10). (orig.)

  20. Final Scientific Report: DE-SC0008580

    Energy Technology Data Exchange (ETDEWEB)

    Seidler, Gerald T. [Univ. of Washington, Seattle, WA (United States)

    2017-03-16

    We report scientific, technical, and organizational accomplishments under DE-SC0008580. This includes 10 publications, 5 patent or provisional patent applications, beamtime with important results at both LCLS and APS, and new progress in understanding target design for x-ray heating experiments at x-ray heating facilities.

  1. The Synchrocyclotron (SC) in building 300

    CERN Multimedia

    Maximilien Brice

    2012-01-01

    The red magnet of CERN's first accelerator, the Synchrocyclotron (SC), has occupied a large part of Hall 300 since it was installed in the late 1950s. The remaining part of the 300-square-metre building has been used as a storage room since the accelerator was shut down in 1990. Now a public exhibition will breathe new life into the hall.

  2. Genetic variation in GIPR influences the glucose and insulin responses to an oral glucose challenge

    DEFF Research Database (Denmark)

    Saxena, Richa; Hivert, Marie-France; Langenberg, Claudia

    2010-01-01

    Glucose levels 2 h after an oral glucose challenge are a clinical measure of glucose tolerance used in the diagnosis of type 2 diabetes. We report a meta-analysis of nine genome-wide association studies (n = 15,234 nondiabetic individuals) and a follow-up of 29 independent loci (n = 6,958-30,620)......Glucose levels 2 h after an oral glucose challenge are a clinical measure of glucose tolerance used in the diagnosis of type 2 diabetes. We report a meta-analysis of nine genome-wide association studies (n = 15,234 nondiabetic individuals) and a follow-up of 29 independent loci (n = 6...

  3. Knowledge insufficient: the management of haemoglobin SC disease.

    Science.gov (United States)

    Pecker, Lydia H; Schaefer, Beverly A; Luchtman-Jones, Lori

    2017-02-01

    Although haemoglobin SC (HbSC) accounts for 30% of sickle cell disease (SCD) in the United States and United Kingdom, evidence-based guidelines for genotype specific management are lacking. The unique pathology of HbSC disease is complex, characterized by erythrocyte dehydration, intracellular sickling and increased blood viscosity. The evaluation and treatment of patients with HbSC is largely inferred from studies of SCD consisting mostly of haemoglobin SS (HbSS) patients. These studies are underpowered to allow definitive conclusions about HbSC. We review the pathophysiology of HbSC disease, including known and potential differences between HbSS and HbSC, and highlight knowledge gaps in HbSC disease management. Clinical and translational research is needed to develop targeted treatments and to validate management recommendations for efficacy, safety and impact on quality of life for people with HbSC. © 2016 John Wiley & Sons Ltd.

  4. Impregnated cathode coated with tungsten thin film containing Sc2O3

    International Nuclear Information System (INIS)

    Yamamoto, S.; Taguchi, S.; Watanabe, I.; Kawase, S.

    1987-01-01

    An impregnated cathode of a novel structure is proposed, fabricated, and evaluated. A thin tungsten film 100--400 nm in thickness containing various amounts of Sc 2 O 3 is coated on a standard impregnated cathode composed of a porous tungsten body in which electron emissive materials are impregnated. The electron emission property measured with a diode configuration is found to be dependent on Sc 2 O 3 content and surface atom distribution. Surface atom distribution is depicted by means of Auger electron spectroscopy. For high electron emission enhancement it is necessary for Sc 2 O 3 content to be 2.5--6.5 wt. % and for a layer of the order of a monolayer in thickness composed of Ba, Sc, and O to develop on the cathode surface

  5. Measurement and COrrelation on Viscosity and Apparent Molar Volume of Ternary System for L—ascorbic Acid in Aqueous D—Glucose and Sucrose Solutions

    Institute of Scientific and Technical Information of China (English)

    赵长伟; 马沛生

    2003-01-01

    Visosities and densities at ,several temperatures from 293.15 K to 313.15K are reported for L-ascorbic acid in aqueous glucose and sucrose solutions at different concentrations.The parameters of density,Viscosity coefficient B and partial molar volume are calculated by regression.The experimental results show that densities and viscositis decrease as temperature increases at the same solute and solvent (glucose and sucrose aueous solution)concentrations,and increase with concentration of glucose and sucrose at the same solute concentration and temperature,B increases with concentration of glucose and sucrose and temaperature,L-ascorbic acid is sturcture-breaker or structure-making for the glucose and sucrose aqueous solutions ,Furthermore,the solute-solvent interactions in ternary systems of water-glucose-electrolyte and water-sucrose-electrolyte are discussed.

  6. Determination of Glucose Concentration in Yeast Culture Medium

    Science.gov (United States)

    Hara, Seiichi; Kishimoto, Tomokazu; Muraji, Masafumi; Tsujimoto, Hiroaki; Azuma, Masayuki; Ooshima, Hiroshi

    The present paper describes a sensor for measuring the glucose concentration of yeast culture medium. The sensor determines glucose concentration by measuring the yield of hydrogen peroxide produced by glucose oxidase, which is monitored as luminescence using photomultiplier. The present sensor is able to measure low glucose concentration in media in which yeast cells keep respiration state. We herein describe the system and the characteristics of the glucose sensor.

  7. Predicting Plasma Glucose From Interstitial Glucose Observations Using Bayesian Methods

    DEFF Research Database (Denmark)

    Hansen, Alexander Hildenbrand; Duun-Henriksen, Anne Katrine; Juhl, Rune

    2014-01-01

    One way of constructing a control algorithm for an artificial pancreas is to identify a model capable of predicting plasma glucose (PG) from interstitial glucose (IG) observations. Stochastic differential equations (SDEs) make it possible to account both for the unknown influence of the continuous...... glucose monitor (CGM) and for unknown physiological influences. Combined with prior knowledge about the measurement devices, this approach can be used to obtain a robust predictive model. A stochastic-differential-equation-based gray box (SDE-GB) model is formulated on the basis of an identifiable...

  8. CORRELATION BETWEEN SEED TESTS AND FIELD EMERGENCE OF TWO MAIZE HYBRIDS (SC704 AND SC500)

    OpenAIRE

    A.A. ALILOO; B. SHOKATI

    2011-01-01

    Early emergence and stand establishment of maize (Zea mays L.) are considered to be the most important yield-contributing factors. The influence of seed vigor on these factors is vital. Therefore, five laboratory tests and field experiment were conducted on basis of a randomized complete block design (RCBD) with five replications in 2011, to evaluate the correlation among the seed vigor tests and field emergence of two maize hybrids (SC704 and SC500). In laboratory tests, differences between ...

  9. Crystal structure and phase stability of AlSc in the near-equiatomic Al–Sc alloy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Juan; Huang, Li; Liang, Yongfeng [State Key Laboratory for Advanced Metals and Materials, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083 (China); Ye, Feng, E-mail: yefeng@skl.ustb.edu.cn [State Key Laboratory for Advanced Metals and Materials, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083 (China); Lin, Junpin [State Key Laboratory for Advanced Metals and Materials, University of Science and Technology Beijing, 30 Xueyuan Road, Beijing 100083 (China); Shang, Shunli; Liu, Zikui [Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA 16802 (United States)

    2015-01-05

    Highlights: • Two lattice structures of equiatomic Al–Sc compounds are confirmed. • Al–Sc phase at Sc 50 at.% has a space group of Pbam. • Al–Sc phase at Sc 55 at.% has a space group of B2. • B2 AlSc is a metastable phase with Sc 50 at.%. • Lattice transition between two compounds is proposed under local thermal stress. - Abstract: Intermetallic compound AlSc is found in the equiatomic Al–Sc binary alloy. The present work indicates that the orthorhombic AlSc with the Au{sub 2}CuZn-type structure can be formed at 50 at.% Sc, while the CsCl-type (B2) AlSc will be formed at 55 at.% Sc. After annealing at 1100 °C, some orthorhombic AlSc grains transit to the B2 structure, and the annealing at lower temperatures leads to the disappearance of B2 phase, indicating that the B2 AlSc is also a metastable phase in the alloy at lower Sc content (<50 at.%). First-principle calculations at 0 K reveal that the orthorhombic AlSc is more stable than the B2 AlSc with the energy difference between them being 5.4 meV/atom. The fast transition between these two phases, which cannot be interpreted by the mechanism of atomic diffusion, was tentatively analyzed by the volume change based on the calculated atomic positions of these two phases.

  10. Molecular and cellular pathogenesis of hemoglobin SC disease.

    OpenAIRE

    Bunn, H F; Noguchi, C T; Hofrichter, J; Schechter, G P; Schechter, A N; Eaton, W A

    1982-01-01

    Solution and cell studies were performed to ascertain why individuals with hemoglobin (Hb) SC have disease whereas those with Hb AS do not. The polymerization of deoxygenated mixtures containing sickle cell Hb (Hb S; alpha 2 beta 2(6)Glu leads to Val) and Hb C (alpha 2 beta 2(6)Glu leads to Lys) was investigated by measurements of delay times and solubilities. In mixtures containing more than 40% Hb S, polymerization takes place by the same mechanism as in solutions of Hb S alone, with no evi...

  11. Gallium-containing Heusler phases ScRh{sub 2}Ga, ScPd{sub 2}Ga, TmRh{sub 2}Ga and LuRh{sub 2}Ga. Magnetic and solid state NMR-spectroscopic characterization

    Energy Technology Data Exchange (ETDEWEB)

    Heletta, Lukas; Seidel, Stefan; Poettgen, Rainer [Muenster Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie; Benndorf, Christopher [Leipzig Univ. (Germany). Inst. fuer Mineralogie, Kristallographie und Materialwissenschaften; Eckert, Hellmut [Muenster Univ. (Germany). Inst. fuer Physikalische Chemie; Sao Paulo Univ., Sao Carlos (Brazil). Inst. of Physics

    2017-10-01

    The gallium-containing Heusler phases ScRh{sub 2}Ga, ScPd{sub 2}Ga, TmRh{sub 2}Ga and LuRh{sub 2}Ga have been synthesized by arc-melting of the elements followed by different annealing sequences to improve phase purity. The samples have been studied by powder X-ray diffraction. The structures of Lu{sub 0.97}Rh{sub 2}Ga{sub 1.03} (Fm3m, a=632.94(5) pm, wR2=0.0590, 46 F{sup 2} values, seven variables) and Sc{sub 0.88}Rh{sub 2}Ga{sub 1.12} (a=618.91(4) pm, wR2=0.0284, 44 F{sup 2} values, six variables) have been refined from single crystal X-ray diffractometer data. Both gallides show structural disorder through Lu/Ga and Sc/Ga mixing. Temperature dependent magnetic susceptibility measurements showed Pauli paramagnetism for ScRh{sub 2}Ga, ScPd{sub 2}Ga, and LuRh{sub 2}Ga and Curie-Weiss paramagnetism for TmRh{sub 2}Ga. {sup 45}Sc and {sup 71}Ga solid state MAS NMR spectroscopic investigations of the Sc containing compounds confirmed the site mixing effects typically observed for Heusler phases. The data indicate that the effect of mixed Sc/Ga occupancy is significantly stronger in ScRh{sub 2}Ga than in ScPd{sub 2}Ga.

  12. Glucose and fructose 6-phosphate cycle in humans

    International Nuclear Information System (INIS)

    Karlander, S.; Roovete, A.; Vranic, M.; Efendic, S.

    1986-01-01

    We have determined the rate of glucose cycling by comparing turnovers of [2- 3 H]- and [6- 3 H]glucose under basal conditions and during a glucose infusion. Moreover, the activity of the fructose 6-phosphate cycle was assessed by comparing [3- 3 H]- and [6- 3 H]glucose. The study included eight lean subjects with normal glucose tolerance. They participated in two randomly performed investigations. In one experiment [2- 3 H]- and [6- 3 H]glucose were given simultaneously, while in the other only [3- 3 H]glucose was given. The basal rate of glucose cycling was 0.32 +/- 0.08 mg X kg-1 X min-1 or 17% of basal glucose production (P less than 0.005). During glucose infusion the activity of endogenous glucose cycling did not change but since glucose production was suppressed it amounted to 130% of glucose production. The basal fructose 6-phosphate cycle could be detected only in three subjects and was suppressed during glucose infusion. In conclusion, the glucose cycle is active in healthy humans both in basal conditions and during moderate hyperglycemia. In some subjects, the fructose 6-phosphate cycle also appears to be active. Thus it is preferable to use [6- 3 H]glucose rather than [3- 3 H]glucose when measuring glucose production and particularly when assessing glucose cycle

  13. Evidence for brain glucose dysregulation in Alzheimer's disease.

    Science.gov (United States)

    An, Yang; Varma, Vijay R; Varma, Sudhir; Casanova, Ramon; Dammer, Eric; Pletnikova, Olga; Chia, Chee W; Egan, Josephine M; Ferrucci, Luigi; Troncoso, Juan; Levey, Allan I; Lah, James; Seyfried, Nicholas T; Legido-Quigley, Cristina; O'Brien, Richard; Thambisetty, Madhav

    2018-03-01

    It is unclear whether abnormalities in brain glucose homeostasis are associated with Alzheimer's disease (AD) pathogenesis. Within the autopsy cohort of the Baltimore Longitudinal Study of Aging, we measured brain glucose concentration and assessed the ratios of the glycolytic amino acids, serine, glycine, and alanine to glucose. We also quantified protein levels of the neuronal (GLUT3) and astrocytic (GLUT1) glucose transporters. Finally, we assessed the relationships between plasma glucose measured before death and brain tissue glucose. Higher brain tissue glucose concentration, reduced glycolytic flux, and lower GLUT3 are related to severity of AD pathology and the expression of AD symptoms. Longitudinal increases in fasting plasma glucose levels are associated with higher brain tissue glucose concentrations. Impaired glucose metabolism due to reduced glycolytic flux may be intrinsic to AD pathogenesis. Abnormalities in brain glucose homeostasis may begin several years before the onset of clinical symptoms. Copyright © 2017 the Alzheimer's Association. All rights reserved.

  14. Hemoglobin C, S-C, and E Diseases

    Science.gov (United States)

    ... quickly than others, resulting in chronic anemia. Hemoglobin C disease Hemoglobin C disease occurs mostly in blacks. ... a common complication of hemoglobin C disease. Hemoglobin S-C disease Hemoglobin S-C disease occurs in people who ...

  15. On-line measurements of oscillating mitochondrial membrane potential in glucose-fermenting Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Andersen, Ann Zahle; Poulsen, Allan K.; Brasen, Jens Christian

    2007-01-01

    We employed the fluorescent cyanine dye DiOC(2)(3) to measure membrane potential in semi-anaerobic yeast cells under conditions where glycolysis was oscillating. Oscillations in glycolysis were studied by means of the naturally abundant nicotinamide adenine dinucleotide (NADH). We found...... studies showed that glycolytic oscillations perturb the mitochondrial membrane potential and that the mitochondria do not have any controlling effect on the dynamics of glycolysis under these conditions. Depolarization of the mitochondrial membrane by addition of FCCP quenched mitochondrial membrane...... potential oscillations and delocalized DiOC(2)(3), while glycolysis continued to oscillate unaffected....

  16. Glucose and cardiovascular risk

    NARCIS (Netherlands)

    Fuchs, M.; Hoekstra, J. B. L.; Mudde, A. H.

    2002-01-01

    The American Diabetes Association and the World Health Organisation have recently redefined the spectrum of abnormal glucose tolerance. The criteria for diabetes mellitus were sharpened and impaired fasting glucose (IFG) and impaired glucose tolerance (IGT) were classified as intermediate stages

  17. Design of SC solenoid with high homogeneity

    International Nuclear Information System (INIS)

    Yang Xiaoliang; Liu Zhong; Luo Min; Luo Guangyao; Kang Qiang; Tan Jie; Wu Wei

    2014-01-01

    A novel kind of SC (superconducting) solenoid coil is designed to satisfy the homogeneity requirement of the magnetic field. In this paper, we first calculate the current density distribution of the solenoid coil section through the linear programming method. Then a traditional solenoid and a nonrectangular section solenoid are designed to produce a central field up to 7 T with a homogeneity to the greatest extent. After comparison of the two solenoid coils designed in magnet field quality, fabrication cost and other aspects, the new design of the nonrectangular section of a solenoid coil can be realized through improving the techniques of framework fabrication and winding. Finally, the outlook and error analysis of this kind of SC magnet coil are also discussed briefly. (authors)

  18. LHCb Data Replication During SC3

    CERN Multimedia

    Smith, A

    2006-01-01

    LHCb's participation in LCG's Service Challenge 3 involves testing the bulk data transfer infrastructure developed to allow high bandwidth distribution of data across the grid in accordance with the computing model. To enable reliable bulk replication of data, LHCb's DIRAC system has been integrated with gLite's File Transfer Service middleware component to make use of dedicated network links between LHCb computing centres. DIRAC's Data Management tools previously allowed the replication, registration and deletion of files on the grid. For SC3 supplementary functionality has been added to allow bulk replication of data (using FTS) and efficient mass registration to the LFC replica catalog.Provisional performance results have shown that the system developed can meet the expected data replication rate required by the computing model in 2007. This paper details the experience and results of integration and utilisation of DIRAC with the SC3 transfer machinery.

  19. Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients.

    Directory of Open Access Journals (Sweden)

    Jérôme Allardet-Servent

    Full Text Available Rapid detection of abnormal biological values using point-of-care (POC testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose.314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800. BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability.Biases, limits of agreement (±1.96 SD and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936 for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944 for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967 for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968 for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972 for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985 for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981 for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin.Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.

  20. Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients.

    Science.gov (United States)

    Allardet-Servent, Jérôme; Lebsir, Melissa; Dubroca, Christian; Fabrigoule, Martine; Jordana, Sylvie; Signouret, Thomas; Castanier, Matthias; Thomas, Guillemette; Soundaravelou, Rettinavelou; Lepidi, Anne; Delapierre, Laurence; Penaranda, Guillaume; Halfon, Philippe; Seghboyan, Jean-Marie

    2017-01-01

    Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.

  1. Original Research: Use of hydroxyurea and phlebotomy in pediatric patients with hemoglobin SC disease.

    Science.gov (United States)

    Summarell, Carly C Ginter; Sheehan, Vivien A

    2016-04-01

    Hydroxyurea is an excellent therapeutic agent for the pharmacological induction of HbF in patients with sickle cell disease (SCD). However, all completed clinical trials of hydroxyurea have excluded patients with hemoglobin SC (HbSC) disease. HbSC differs significantly in pathophysiology from HbSS, as HbC does not sickle, but instead causes cellular dehydration which potentiates sickling of HbS. Many severely affected HbSC patients have been placed on hydroxyurea on a case by case basis, but there are no large scale prospective data on safety or efficacy of hydroxyurea in this subset of patients with SCD. Here, we report a case series of 14 pediatric patients with HbSC treated to maximum tolerated dose (MTD) with hydroxyurea. Those who failed to show clinical improvement after at least six months at MTD were offered phlebotomy in addition to hydroxyurea. Five out of 11 patients with HbSC who achieved MTD failed to demonstrate clinical improvement on hydroxyurea. Of the four placed on dual hydroxyurea and phlebotomy therapy, all showed at least partial clinical improvement. Percent dense red blood cells (%DRBC) were measured via an ADVIA hematology analyzer. A marked rise in percent dense cells preceded clinical complications in three patients. Dual therapy with hydroxyurea and phlebotomy may be an effective approach to patients with HbSC that do not experience improvement with hydroxyurea alone. Monitoring of %DRBC may predict adverse events and aid in assessing hydroxyurea compliance. Large scale clinical trials are needed to evaluate the safety and efficacy of hydroxyurea and hydroxyurea with phlebotomy in patients with HbSC disease. © 2016 by the Society for Experimental Biology and Medicine.

  2. Early Stages of Precipitation Process in Al-(Mn-)Sc-Zr Alloy Characterized by Positron Annihilation

    KAUST Repository

    Vlach, Martin; Cizek, Jakub; Melikhova, Oksana; Stulikova, Ivana; Smola, Bohumil; Kekule, Tomas; Kudrnova, Hana; Gemma, Ryota; Neubert, Volkmar

    2015-01-01

    Thermal effects on the precipitation stages in as-cast Al-0.70 at. pct Mn-0.15 at. pct Sc-0.05 at. pct Zr alloy were studied. The role of lattice defects was elucidated by positron annihilation spectroscopy (lifetime and coincidence Doppler broadening) enabling investigation of solutes clustering at the atomic scale. This technique has never been used in the Al-Sc- and/or Al-Zr-based alloys so far. Studies by positron annihilation were combined with resistometry, hardness measurements, and microstructure observations. Positrons trapped at defects are preferentially annihilated by Sc electrons. Lifetime of trapped positrons indicates that Sc atoms segregate at dislocations. Maximum fraction of positrons annihilated by Sc electrons occurring at 453 K (180 °C) suggests that clustering of Sc bound with vacancies takes place. It is followed by peak of this fraction at 573 K (300 °C). A rise of the contribution of trapped positrons annihilated by Zr electrons starting at 513 K (240 °C) and attaining maximum also at 573 K (300 °C) confirms that Zr participates in precipitation of the Al3Sc particles already at these temperatures. The pronounced hardening at 573 K (300 °C) has its nature in the precipitation of the Al3Sc particles with a Zr-rich shell. The contribution of trapped positrons annihilated by Mn electrons was found to be negligible. © 2015, The Minerals, Metals & Materials Society and ASM International.

  3. Early Stages of Precipitation Process in Al-(Mn-)Sc-Zr Alloy Characterized by Positron Annihilation

    KAUST Repository

    Vlach, Martin

    2015-01-29

    Thermal effects on the precipitation stages in as-cast Al-0.70 at. pct Mn-0.15 at. pct Sc-0.05 at. pct Zr alloy were studied. The role of lattice defects was elucidated by positron annihilation spectroscopy (lifetime and coincidence Doppler broadening) enabling investigation of solutes clustering at the atomic scale. This technique has never been used in the Al-Sc- and/or Al-Zr-based alloys so far. Studies by positron annihilation were combined with resistometry, hardness measurements, and microstructure observations. Positrons trapped at defects are preferentially annihilated by Sc electrons. Lifetime of trapped positrons indicates that Sc atoms segregate at dislocations. Maximum fraction of positrons annihilated by Sc electrons occurring at 453 K (180 °C) suggests that clustering of Sc bound with vacancies takes place. It is followed by peak of this fraction at 573 K (300 °C). A rise of the contribution of trapped positrons annihilated by Zr electrons starting at 513 K (240 °C) and attaining maximum also at 573 K (300 °C) confirms that Zr participates in precipitation of the Al3Sc particles already at these temperatures. The pronounced hardening at 573 K (300 °C) has its nature in the precipitation of the Al3Sc particles with a Zr-rich shell. The contribution of trapped positrons annihilated by Mn electrons was found to be negligible. © 2015, The Minerals, Metals & Materials Society and ASM International.

  4. Reduction of the thermal conductivity of the thermoelectric material ScN by Nb alloying

    DEFF Research Database (Denmark)

    Tureson, Nina; Van Nong, Ngo; Fournier, Daniele

    2017-01-01

    ) orientation. The crystal structure, morphology, thermal conductivity, and thermoelectric and electrical properties were investigated. The ScN reference film exhibited a Seebeck coefficient of −45 μV/K and a power factor of 6 × 10−4 W/m K2 at 750 K. Estimated from room temperature Hall measurements, all...... samples exhibit a high carrier density of the order of 1021 cm−3. Inclusion of heavy transition metals into ScN enables the reduction in thermal conductivity by an increase in phonon scattering. The Nb inserted ScN thin films exhibited a thermal conductivity lower than the value of the ScN reference (10.......5 W m−1 K−1) down to a minimum value of 2.2 Wm−1 K−1. Insertion of Nb into ScN thus resulted in a reduction in thermal conductivity by a factor of ∼5 due to the mass contrast in ScN, which increases the phonon scattering in the material....

  5. SC*994C>T causes the Sc(null) phenotype in Pacific Islanders and successful transfusion of Sc3+ blood to a patient with anti-Sc3.

    Science.gov (United States)

    Reid, Marion E; Hue-Roye, Kim; Velliquette, Randall W; Larimore, Kathleen; Moscarelli, Sue; Ohswaldt, Nicolas; Lomas-Francis, Christine

    2013-01-01

    Antigens in the SC blood group system are expressed by the human erythrocyte membrane-associated protein (ERMAP).Two molecular bases have been reported for the Sc,un phenotype:SC*307del2 and SC*994C>T. We report our investigation of the molecular background of five Sc,n1 individuals from the Pacific Islands and describe the successful transfusion of Sc3+ blood to a patient with anti-Sc3 in her plasma. SC (ERMAP) exons 2,3, and 12 and their flanking intronic regions were analyzed. TheSC*994C>T change introduces a restriction enzyme cleavage site for Tsp45I, and polymerase chain reaction (PCR) products from exon 12 were subjected to this PCR-restriction fragment length polymorphism (RFLP) assay. The five samples had the variant SC*994T/T. One sample, from a first cousin of one Marshallese proband, was heterozygous for SC*1514C/T (in the 3' untranslated region); the other four samples were SC*1514C/C(consensus sequence). Samples from white donors (n = 100) and African American donors (n = 99) were tested using the Tsp45IPCR-RFLP assay; all gave a banding pattern that was consistent with the SC*994C/C consensus sequence. In all five samples,our analyses showed homozygosity for the nonsense nucleotide change SC*994C>Tin an allele carrying the nucleotide associated with SLd. Further investigation determined that one of the probands reported previously with the SC*994C>T change was from the Marshall Islands (which form part of the Micronesian Pacific Islands) and the other was from an unspecified location within the large collection of Pacific Islands. Taken together, the five known probands with the SC*994C>T silencing nucleotide change were from the Pacific Islands.

  6. The SC gets ready for visitors

    CERN Multimedia

    Antonella Del Rosso

    2012-01-01

    Hall 300, which houses the Synchrocyclotron (SC), CERN’s first accelerator, is getting ready to host a brand-new exhibition. The site will be one of the stops on the new visit itineraries that will be inaugurated for the 2013 CERN Open Day.   The Synchrocyclotron through the years. Just as it did in the late 1950s, when the accelerator was first installed, the gigantic red structure of the Synchrocyclotron's magnet occupies a large part of the 300-square-metre hall. “We have completed the first phase of the project that will give the SC a new lease of life,” says Marco Silari, the project leader and a member of CERN’s Radiation Protection Group. “We have removed all the equipment that was not an integral part of the accelerator. The hall is now ready for the civil-engineering work that will precede the installation of the exhibition.” The SC was witness to a big part of the history of CERN. The accelerator produced ...

  7. Estimation of liver glucose metabolism after refeeding

    International Nuclear Information System (INIS)

    Rognstad, R.

    1987-01-01

    Refeeding or infusing glucose to rats fasted for 24 hr or more causes rapid liver glycogen synthesis, the carbon source now considered to be largely from gluconeogenesis. While substrate cycling between plasma glucose and liver glucose-6P is known to occur, this cycling has apparently been ignored when calculations are made of % contribution of direct and indirect pathways to liver glycogen synthesis, or when hepatic glucose output is calculated from glucose turnover minus the glucose infusion rate. They show that, isotopically, an estimate of the fluxes of liver glucokinase and glucose-6-phosphatase is required to quantitate sources of carbon for liver glycogen synthesis, and to measure hepatic glucose output (or uptake). They propose a method to estimate these fluxes, involving a short infusion of a 14 C labelled gluconeogenic precursor plus (6T)glucose, with determination of isotopic yields in liver glycogen and total glucose. Given also the rate of liver glycogen synthesis, this procedure permits the estimation of net gluconeogenesis and hepatic glucose output or uptake. Also, in vitro evidence against the notion of a drastic zonation of liver carbohydrate metabolism is presented, e.g. raising the glucose concentration from 10 to 25 mM increases the 14 C yield from H 14 CO 3 - in lactate, with the increased pyruvate kinase flux and decreased gluconeogenesis occurring in the same cell type, not opposing pathways in different hepatocyte types (as has been postulated by some to occur in vivo after refeeding

  8. Continuous glucose monitoring systems for type 1 diabetes mellitus

    NARCIS (Netherlands)

    Langendam, Miranda; Luijf, Yoeri M.; Hooft, Lotty; DeVries, J. Hans; Mudde, Aart H.; Scholten, Rob J. P. M.

    2012-01-01

    Background Self-monitoring of blood glucose is essential to optimise glycaemic control in type 1 diabetes mellitus. Continuous glucose monitoring (CGM) systems measure interstitial fluid glucose levels to provide semi-continuous information about glucose levels, which identifies fluctuations that

  9. Genetic variation in GIPR influences the glucose and insulin responses to an oral glucose challenge

    NARCIS (Netherlands)

    R. Saxena (Richa); M.-F. Hivert (Marie-France); C. Langenberg (Claudia); T. Tanaka (Toshiko); J.S. Pankow (James); P. Vollenweider (Peter); V. Lyssenko (Valeriya); N. Bouatia-Naji (Nabila); J. Dupuis (Josée); A.U. Jackson (Anne); W.H.L. Kao (Wen); M. Li (Man); N.L. Glazer (Nicole); A.K. Manning (Alisa); J. Anluan (Jian); H.M. Stringham (Heather); I. Prokopenko (Inga); T. Johnson (Toby); N. Grarup (Niels); T.W. Boesgaard (Trine); C. Lecoeur (Cécile); P. Shrader (Peter); J.R. O´Connell; E. Ingelsson (Erik); D.J. Couper (David); K. Rice (Kenneth); K. Song (Kijoung); C.H. Andreasen (Camilla); C. Dina (Christian); A. Köttgen (Anna); O.L. Bacquer (Olivier); F. Pattou (François); J. Taneera (Jalal); V. Steinthorsdottir (Valgerdur); D. Rybin (Denis); K.G. Ardlie (Kristin); M.J. Sampson (Michael); L. Qi (Lu); M.V. Hoek; M.N. Weedon (Michael); Y.S. Aulchenko (Yurii); B.F. Voight (Benjamin); H. Grallert (Harald); B. Balkau (Beverley); R.N. Bergman (Richard); S.J. Bielinski (Suzette); A. Bonnefond (Amélie); L.L. Bonnycastle (Lori); K. Borch-Johnsen; Y. Böttcher (Yvonne); E. Brunner (Eric); T.A. Buchanan (Thomas); S. Bumpstead (Suzannah); C. Cavalcanti-Proença (Christine); G. Charpentier (Guillaume); Y.D.I. Chen (Yii-Der Ida); P.S. Chines (Peter); F.S. Collins (Francis); M. Cornelis (Marilyn); G. Crawford (Gabe); J. Delplanque (Jerome); A.S.F. Doney (Alex); J.M. Egan (Josephine); M.R. Erdos (Michael); M. Firmann (Mathieu); N.G. Forouhi (Nita); C.S. Fox (Caroline); M. Goodarzi (Mark); J. Graessler (Jürgen); A. Hingorani (Aroon); B. Isomaa (Bo); T. Jørgensen (Torben); M. Kivimaki (Mika); P. Kovacs (Peter); K. Krohn (Knut); M. Kumari (Meena); T. Lauritzen (Torsten); C. Lévy-Marchal (Claire); V. Mayor (Vladimir); J.B. McAteer (Jarred); D. Meyre (David); B.D. Mitchell (Braxton); K.L. Mohlke (Karen); M.A. Morken (Mario); N. Narisu (Narisu); C.N.A. Palmer (Colin); R. Pakyz (Ruth); L. Pascoe (Laura); F. Payne (Felicity); D. Pearson (Daniel); W. Rathmann (Wolfgang); A. Sandbaek (Annelli); A.A. Sayer; L.J. Scott (Laura); S.J. Sharp (Stephen); E.J.G. Sijbrands (Eric); A. Singleton (Andrew); D.S. Siscovick (David); N.L. Smith (Nicholas); T. Sparsø (Thomas); A.J. Swift (Amy); H. Syddall (Holly); G. Thorleifsson (Gudmar); A. Tönjes (Anke); T. Tuomi (Tiinamaija); J. Tuomilehto (Jaakko); T.T. Valle (Timo); G. Waeber (Gérard); A. Walley (Andrew); D. Waterworth (Dawn); E. Zeggini (Eleftheria); J.H. Zhao (Jing Hua); G. Consortium (Giant); T. Illig (Thomas); H.E. Wichmann (Erich); J.F. Wilson (James); C.M. van Duijn (Cornelia); F.B. Hu (Frank); A.D. Morris (Andrew); T.M. Frayling (Timothy); A.T. Hattersley (Andrew); U. Thorsteinsdottir (Unnur); J-A. Zwart (John-Anker); P. Nilsson (Peter); A.C. Syvänen; A.R. Shuldiner (Alan); M. Walker (Mark); S.R. Bornstein (Stefan); P. Schwarz (Peter); G.H. Williams (Gordon); D.M. Nathan (David); J. Kuusisto (Johanna); M. Laakso (Markku); C. Cooper (Charles); M. Marmot (Michael); L. Ferrucci (Luigi); V. Mooser (Vincent); M. Stumvoll (Michael); R.J.F. Loos (Ruth); D. Altshuler (David); B.M. Psaty (Bruce); J.I. Rotter (Jerome); E.A. Boerwinkle (Eric); T. Hansen (Torben); O. Pedersen (Oluf); J.C. Florez (Jose); M.I. McCarthy (Mark); M. Boehnke (Michael); I.E. Barroso (Inês); R. Sladek (Rob); P. Froguel (Philippe); J.B. Meigs (James); L. Groop (Leif); N.J. Wareham (Nick); R.M. Watanabe (Richard)

    2010-01-01

    textabstractGlucose levels 2 h after an oral glucose challenge are a clinical measure of glucose tolerance used in the diagnosis of type 2 diabetes. We report a meta-analysis of nine genome-wide association studies (n = 15,234 nondiabetic individuals) and a follow-up of 29 independent loci (n =

  10. Glucose reactivity with filling materials as a limitation for using the glucose leakage model

    NARCIS (Netherlands)

    Shemesh, H.; Souza, E.M.; Wu, M.K.; Wesselink, P.R.

    2008-01-01

    Aim To evaluate the reactivity of different endodontic materials and sealers with glucose and to asses the reliability of the glucose leakage model in measuring penetration of glucose through these materials. Methodology Ten uniform discs (radius 5 mm, thickness 2 mm) were made of each of the

  11. The effect of glucose stimulation on 45calcium uptake of rat pancreatic islets and their total calcium content as measured by a fluorometric micro-method

    International Nuclear Information System (INIS)

    Wolters, G.H.J.; Wiegman, J.B.; Konijnendijk, W.

    1982-01-01

    Glucose-stimulated 45 calcium uptake and total calcium content of rat pancreatic islets has been studied, using a new fluorometric micro-method to estimate total calcium. Extracellular calcium was separated from incubated tissue by a rapid micro-filtration procedure. Islets incubated up to 60 min with calcium chloride 2.5 mmol/l and glucose 2.5 mmol/l maintained the same calcium content (670 +- 7.5 pmol/μg DNA). When the glucose concentration was raised to 15 mmol/l no change in the total calcium content could be detected. On incubation with glucose 2.5 mmol/l in the absence of calcium, the calcium content decreased to 488 +- 27 pmol/μg DNA. On incubation with 45 calcium chloride 2.5 mmol/l for 5 or 30 min at 2.5 mmol/l glucose, islets exchanged 21 +- 2 and 28 +- 1% of their total calcium content and, at 15 mmol/l glucose, 30 +- 3 and 45 +- 2%, respectively. Thus, islet calcium has a high turn-over rate. Glucose stimulation results in an increase of the calcium uptake without enhancing the total calcium content and hence must increase the calcium-exchangeable pool. (orig.)

  12. Crystal, magnetic, calorimetric and electronic structure investigation of GdScGe1-x Sb x compounds

    Science.gov (United States)

    Guillou, F.; Pathak, A. K.; Hackett, T. A.; Paudyal, D.; Mudryk, Y.; Pecharsky, V. K.

    2017-12-01

    Experimental investigations of crystal structure, magnetism and heat capacity of compounds in the pseudoternary GdScGe-GdScSb system combined with density functional theory projections have been employed to clarify the interplay between the crystal structure and magnetism in this series of RTX materials (R  =  rare-earth, T   =  transition metal and X  =  p-block element). We demonstrate that the CeScSi-type structure adopted by GdScGe and CeFeSi-type structure adopted by GdScSb coexist over a limited range of compositions 0.65 ≤slant x ≤slant 0.9 . Antimony for Ge substitutions in GdScGe result in an anisotropic expansion of the unit cell of the parent that is most pronounced along the c axis. We believe that such expansion acts as the driving force for the instability of the double layer CeScSi-type structure of the parent germanide. Extensive, yet limited Sb substitutions 0 ≤slant x disappearance of the induced magnetic moments on Sc. For the parent antimonide, heat capacity measurements indicate an additional transition below the main antiferromagnetic transition.

  13. CMOS image sensor-based implantable glucose sensor using glucose-responsive fluorescent hydrogel.

    Science.gov (United States)

    Tokuda, Takashi; Takahashi, Masayuki; Uejima, Kazuhiro; Masuda, Keita; Kawamura, Toshikazu; Ohta, Yasumi; Motoyama, Mayumi; Noda, Toshihiko; Sasagawa, Kiyotaka; Okitsu, Teru; Takeuchi, Shoji; Ohta, Jun

    2014-11-01

    A CMOS image sensor-based implantable glucose sensor based on an optical-sensing scheme is proposed and experimentally verified. A glucose-responsive fluorescent hydrogel is used as the mediator in the measurement scheme. The wired implantable glucose sensor was realized by integrating a CMOS image sensor, hydrogel, UV light emitting diodes, and an optical filter on a flexible polyimide substrate. Feasibility of the glucose sensor was verified by both in vitro and in vivo experiments.

  14. Observing environmental European legislation - strategic priority of SC Termoelectrica

    International Nuclear Information System (INIS)

    Pop, Ovidiu; Motiu, Cornel

    2004-01-01

    Defined as the main Romanian power producer, SC Termoelectrica is also a Company that faced over 50 years of experience and confrontations with different technical, economical and legislative problems. The measures of restructuring that were taken during the last years, also included a program of retiring of use of some inefficient and in excess units. That brought our company at its actual structure that consists in producing, repairs and services units, organized as commercial societies and subsidiaries of SC Termoelectrica. The activity of producing thermal and electric power using old power equipment (33.84% of them are over 30 years old, 46.54% are between 10-20 years old and only 0.64 % are under 10 years old) and without control pollution installations or having inefficient installations, led to the increasing of some environmental problems along the years. The paper has the following structure: - Introduction; - Actual situation; - The accession to the European Union - the control of industrial pollution (The abatement of atmospheric, water and soil pollution); - The mitigation of greenhouse gases. In conclusion one stresses that no matter which will be the way of organization the environmental approach at European or national level, these will become a strategic priority for SC Termoelectrica. The way these environmental problems will be solved will have a great influence on: - The company's thermal power plants work, while their impact upon the local, regional and global environment will be almost nonexistent; - The offer of electric power produced by thermal power plants in national and international transactions; - The fulfillment of the three objectives of a power producer: accessibility, availability and acceptability

  15. Detecting early kidney damage in horses with colic by measuring matrix metalloproteinase -9 and -2, other enzymes, urinary glucose and total proteins

    Directory of Open Access Journals (Sweden)

    Salonen Hanna

    2007-01-01

    Full Text Available Abstract Background The aim of the study was to investigate urine matrix metalloproteinase (MMP-2 and -9 activity, alkaline phosphatase/creatinine (U-AP/Cr and gamma-glutamyl-transpeptidase/creatinine (U-GGT/Cr ratios, glucose concentration, and urine protein/creatinine (U-Prot/Cr ratio and to compare data with plasma MMP-2 and -9 activity, cystatin-C and creatinine concentrations in colic horses and healthy controls. Horses with surgical colic (n = 5 were compared to healthy stallions (n = 7 that came for castration. Blood and urine samples were collected. MMP gelatinolytic activity was measured by zymography. Results We found out that horses with colic had significantly higher urinary MMP-9 complex and proMMP-9 activities than horses in the control group. Colic horses also had higher plasma MMP-2 activity than the control horses. Serum creatinine, although within reference range, was significantly higher in the colic horses than in the control group. There was no significant increase in urinary alkaline phosphatase, gamma-glutamyltranspeptidase or total proteins in the colic horses compared to the control group. A human cystatin-C test (Dako Cytomation latex immunoassay® based on turbidimetry did not cross react with equine cystatin-C. Conclusion The results indicate that plasma MMP-2 may play a role in the pathogenesis of equine colic and urinary MMP-9 in equine kidney damage.

  16. Heterogeneity of Glucose Metabolism in Esophageal Cancer Measured by Fractal Analysis of Fluorodeoxyglucose Positron Emission Tomography Image: Correlation between Metabolic Heterogeneity and Survival.

    Science.gov (United States)

    Tochigi, Toru; Shuto, Kiyohiko; Kono, Tsuguaki; Ohira, Gaku; Tohma, Takayuki; Gunji, Hisashi; Hayano, Koichi; Narushima, Kazuo; Fujishiro, Takeshi; Hanaoka, Toshiharu; Akutsu, Yasunori; Okazumi, Shinichi; Matsubara, Hisahiro

    2017-01-01

    Intratumoral heterogeneity is a well-recognized characteristic feature of cancer. The purpose of this study is to assess the heterogeneity of the intratumoral glucose metabolism using fractal analysis, and evaluate its prognostic value in patients with esophageal squamous cell carcinoma (ESCC). 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) studies of 79 patients who received curative surgery were evaluated. FDG-PET images were analyzed using fractal analysis software, where differential box-counting method was employed to calculate the fractal dimension (FD) of the tumor lesion. Maximum standardized uptake value (SUVmax) and FD were compared with overall survival (OS). The median SUVmax and FD of ESCCs in this cohort were 13.8 and 1.95, respectively. In univariate analysis performed using Cox's proportional hazard model, T stage and FD showed significant associations with OS (p = 0.04, p heterogeneity measured by fractal analysis can be a novel imaging biomarker for survival in patients with ESCC. © 2016 S. Karger AG, Basel.

  17. The impact of a low glycaemic index (GI diet on simultaneous measurements of blood glucose and fat oxidation: A whole body calorimetric study

    Directory of Open Access Journals (Sweden)

    Bhupinder Kaur

    2016-06-01

    Conclusions: Consumption of LGI meals was capable of attenuating 24-hour blood glucose profiles and decreasing postprandial glucose excursions in healthy Asian males. Additionally, LGI mixed meals were able to promote fat oxidation over carbohydrate oxidation when compared to HGI mixed meals. The consumption of low GI meals may be a strategic approach in improving overall glycaemia and increasing fat oxidation in Asians consuming a high carbohydrate diet.

  18. Formation of scandium nitride (ScN) layer on gallium arsenide (GaAs) substrate using a combined technique of e-beam evaporator and ammonia annealing treatment

    International Nuclear Information System (INIS)

    Yong Shee Meng, Alvin; Zainal, Norzaini; Hassan, Zainuriah; Ibrahim, Kamarulazizi

    2015-01-01

    Graphical abstract: - Highlights: • Forming ScN layer using electron e-beam evaporator with successive NH_3 annealing thermal has been successfully demonstrated. • NH_3 annealing played the role in changing the grain structure of the ScN layer. • The existence of Sc−N bonds was confirmed by XPS measurement. • The 900 °C annealed ScN layer showed the best structural and optical characteristics. • ScN layer annealed at 980 °C exhibited poor structural and optical characteristics. - Abstract: A demonstration on a new technique of growing ScN using electron beam (e-beam) evaporator, coupled with successive ammonia (NH_3) annealing treatment is presented in this paper. The annealing temperature was varied at 750, 800, 850, 900 and 980 °C in order to obtain the best ScN layer. It was found that as the annealing temperature increased, the surface morphology of the ScN layer changed and ScN grains formed abundantly on the surface. The best surface of ScN layer was found in the 900 °C annealed sample. However, the roughness of the ScN increased with temperature. The photoluminescence (PL) peak of the near-to-band-edge (NBE) of ScN was observable in all samples and its intensity was the highest in the 900 °C annealed sample. Note that when the annealing treatment was conducted at 980 °C, the GaN PL peak is observable. Raman peaks of TO(X) of ScN were much evident at the annealing temperature above 900 °C. The formation of Sc−N bonds was confirmed by X-ray spectroscopy (XPS) measurement. In the end of this work, we propose that the formation of ScN using the above techniques was successful, with thermal annealing at the temperature of 900 °C.

  19. Detection of Metallothionein in Javanese Medaka (Oryzias javanicus, Using a scFv-Immobilized Protein Chip

    Directory of Open Access Journals (Sweden)

    Euiyeon Lee

    2018-04-01

    Full Text Available Environmental pollution by various industrial chemicals and biological agents poses serious risks to human health. Especially, marine contamination by potentially toxic elements (PTEs has become a global concern in recent years. Many efforts have been undertaken to monitor the PTE contamination of the aquatic environment. However, there are few approaches available to assess the PTE exposure of aquatic organisms. In this research, we developed a strategy to evaluate the heavy metal exposure of marine organisms, by measuring the expression levels of metallothionein protein derived from Oryzias javanicus (OjaMT. OjaMT is a biomarker of heavy metal exposure because the expression level increases upon heavy metal exposure. The developed assay is based on a real-time, label-free surface plasmon resonance (SPR measurement. Anti-OjaMT antibody and anti-OjaMT single-chain fragment of variable region (scFv were used as detection probes. Two types of SPR sensor chips were fabricated, by immobilizing antibody or Cys3-tagged scFv (scFv-Cys3 in a controlled orientation and were tested for in situ label-free OjaMT detection. Compared to the antibody-presenting sensor chips, the scFv-presenting sensor chips showed improved performance, displaying enhanced sensitivity and enabling semi-quantitative detection. The portable SPR system combined with scFv-immobilized sensor chips is expected to provide an excellent point-of-care testing system that can monitor target biomarkers in real time.

  20. Parsing glucose entry into the brain: novel findings obtained with enzyme-based glucose biosensors.

    Science.gov (United States)

    Kiyatkin, Eugene A; Wakabayashi, Ken T

    2015-01-21

    Extracellular levels of glucose in brain tissue reflect dynamic balance between its gradient-dependent entry from arterial blood and its use for cellular metabolism. In this work, we present several sets of previously published and unpublished data obtained by using enzyme-based glucose biosensors coupled with constant-potential high-speed amperometry in freely moving rats. First, we consider basic methodological issues related to the reliability of electrochemical measurements of extracellular glucose levels in rats under physiologically relevant conditions. Second, we present data on glucose responses induced in the nucleus accumbens (NAc) by salient environmental stimuli and discuss the relationships between local neuronal activation and rapid glucose entry into brain tissue. Third, by presenting data on changes in NAc glucose induced by intravenous and intragastric glucose delivery, we discuss other mechanisms of glucose entry into the extracellular domain following changes in glucose blood concentrations. Lastly, by showing the pattern of NAc glucose fluctuations during glucose-drinking behavior, we discuss the relationships between "active" and "passive" glucose entry to the brain, its connection to behavior-related metabolic activation, and the possible functional significance of these changes in behavioral regulation. These data provide solid experimental support for the "neuronal" hypothesis of neurovascular coupling, which postulates the critical role of neuronal activity in rapid regulation of vascular tone, local blood flow, and entry of glucose and oxygen to brain tissue to maintain active cellular metabolism.

  1. Impact of Glucose Tolerance Status, Sex, and Body Size on Glucose Absorption Patterns During OGTTs

    DEFF Research Database (Denmark)

    Faerch, K.; Pacini, G.; Nolan, J. J.

    2013-01-01

    OBJECTIVEWe studied whether patterns of glucose absorption during oral glucose tolerance tests (OGTTs) were abnormal in individuals with impaired glucose regulation and whether they were related to sex and body size (height and fat-free mass). We also examined how well differences in insulin......, reflected the differences for these parameters between those with normal and impaired glucose regulation as measured by gold-standard tests.CONCLUSIONSGlucose absorption patterns during an OGTT are significantly related to plasma glucose levels and body size, which should be taken into account when.......RESULTSMore rapid glucose absorption (P 0.036) and reduced late glucose absorption (P 0.039) were observed in the i-IFG group relative to NGT and i-IGT groups. Women with i-IGT had a lower early glucose absorption than did men with i-IGT (P = 0.041); however, this difference did not persist when differences in body...

  2. Glucose metabolism in diabetic blood vessels

    International Nuclear Information System (INIS)

    Brown, B.J.; Crass, M.F. III

    1986-01-01

    Since glycolysis appears to be coupled to active ion transport in vascular smooth muscle, alterations in glucose metabolism may contribute to cellular dysfunction and angiopathy in diabetes. Uptake and utilization of glucose were studied in perfused blood vessels in which pulsatile flow and perfusion pressure were similar to those measured directly in vivo. Thoracic aortae isolated from 8-wk alloxan diabetic (D) and nondiabetic control rabbits were cannulated, tethered, and perfused with oxygenated buffer containing 7 or 25 mM glucose and tracer amounts of glucose-U -14 C. Norepinephrine (NE) (10 -6 M) and/or insulin (I) (150 μU/ml) and albumin (0.2%) were added. NE-induced tension development increased glucose uptake 39% and 14 CO 2 and lactate production 2.3-fold. With 7 mM glucose, marked decreases in glucose uptake (74%), 14 CO 2 (68%), lactate (30%), total tissue glycogen (75%), and tissue phospholipids (70%) were observed in D. Addition of I or elevation of exogenous glucose to 25 mM normalized glucose uptake, but had differential effects on the pattern of substrate utilization. Thus, in D, there was a marked depression of vascular glucose metabolism that was partially reversed by addition of low concentrations of insulin or D levels of glucose

  3. Glucose kinetics in infants of diabetic mothers

    International Nuclear Information System (INIS)

    Cowett, R.M.; Susa, J.B.; Giletti, B.; Oh, W.; Schwartz, R.

    1983-01-01

    Glucose kinetic studies were performed to define the glucose turnover rate with 78% enriched D-[U-13C] glucose by the prime constant infusion technique at less than or equal to 6 hours of age in nine infants of diabetic mothers (four insulin-dependent and five chemical diabetic patients) at term. Five normal infants were studied as control subjects. All infants received 0.9% saline intravenously during the study with the tracer. Fasting plasma glucose, insulin, and glucose13/12C ratios were measured during the steady state, and the glucose turnover rate was derived. The average plasma glucose concentration was similar during the steady state in the infants of the diabetic mothers and in the control infants, and the glucose turnover rate was not significantly different among the groups: 2.3 +/- 0.6 mg . kg-1 min-1 in infants of insulin-dependent diabetic patients; 2.4 +/- 0.4 mg . kg-1 min-1 in infants of chemical diabetic patients; and 3.2 +/- 0.3 mg . kg-1 min-1 in the control subjects. Good control of maternal diabetes evidenced by the normal maternal hemoglobin A1c and plasma glucose concentration at delivery and cord plasma glucose concentration resulted in glucose kinetic values in the infants of diabetic mothers that were indistinguishable from those of control subjects. The data further support the importance of good control of the diabetic state in the pregnant woman to minimize or prevent neonatal hypoglycemia

  4. Negative thermal expansion in Sc2(WO4)3

    International Nuclear Information System (INIS)

    Evans, J.S.O.; Mary, T.A.; Sleight, A.W.

    1998-01-01

    Sc 2 (WO 4 ) 3 has been found to show the highly unusual property of negative thermal expansion over a temperature range of 10 to 1,073 K. Powder neutron diffraction data from 10 to 450 K shows an essentially linear decrease in cell volume as a function of temperature. The intrinsic linear coefficient of thermal expansion from this data is -2.2 x 10 -6 K -1 . The linear coefficient of thermal expansion measured on a ceramic bar of Sc 2 (WO 4 ) 3 can be as negative as -11 x 10 -6 K -1 due to microstructure changes as a function of temperature. Rietveld refinement as a function of temperature suggests that the intrinsic negative thermal expansion can be related to transverse vibrations of bridging oxygen atoms in the structure. The anharmonic nature of these vibrations leads to a coupled tilting of the quasi-rigid framework polyhedra. This tilting in turn causes the structure to become more dense with increasing temperature

  5. Timescale differences between SC-PDSI and SPEI for drought monitoring in China

    Science.gov (United States)

    Zhao, Haiyan; Gao, Ge; An, Wei; Zou, Xukai; Li, Haitao; Hou, Meiting

    2017-12-01

    The Palmer Drought Severity Index (PDSI) has been widely used to monitor drought. Its characteristics are more suitable for measuring droughts of longer timescales, and this fact has not received much attention. The Standardized Precipitation Evapotranspiration Index (SPEI) can better reflect the climatic water balance, owing to its combination of precipitation and potential evapotranspiration. In this study, we selected monthly average air temperature and precipitation data from 589 meteorological stations of China's National Meteorological Information Center, to compare the effects of applying a self-calibrating PDSI (SC-PDSI) and SPEI to monitor drought events in the station regions, with a special focus on differences of event timescale. The results show the following. 1) Comparative analysis using SC-PDSI and SPEI for drought years and characters of three dry periods from 1961 to 2011 in the Beijing region showed that durations of SC-PDSI-based dry spells were longer than those of 3-month and 6-month SPEIs, but equal to those of 12-month or longer timescale SPEIs. 2) For monitoring evolution of the fall 2009 to spring 2010 Southwest China drought and spring 2000 Huang-Huai drought, 3-month SPEI could better monitor the initiation, aggravation, alleviation and relief of drought in the two regions, whereas the SC-PDSI was insensitive to drought recovery because of its long-term memory of previous climate conditions. 3) Analysis of the relationship between SC-PDSI for different regions and SPEI for different timescales showed that correlation of the two indexes changed with region, and SC-PDSI was maximally correlated with SPEI of 9-19 months in China. Therefore, SC-PDSI is only suitable for monitoring mid- and long-term droughts, owing to the strong lagged autocorrelation such as 0.4786 for 12-month lagged ones in Beijing, whereas SPEI is suitable for both short- and long-term drought-monitoring and should have greater application prospects in China.

  6. High Reflectance Nanoscale V/Sc Multilayer for Soft X-ray Water Window Region.

    Science.gov (United States)

    Huang, Qiushi; Yi, Qiang; Cao, Zhaodong; Qi, Runze; Loch, Rolf A; Jonnard, Philippe; Wu, Meiyi; Giglia, Angelo; Li, Wenbin; Louis, Eric; Bijkerk, Fred; Zhang, Zhong; Wang, Zhanshan

    2017-10-10

    V/Sc multilayer is experimentally demonstrated for the first time as a high reflectance mirror for the soft X-ray water window region. It primarily works at above the Sc-L edge (λ = 3.11 nm) under near normal incidence while a second peak appears at above the V-L edge (λ = 2.42 nm) under grazing incidence. The V/Sc multilayer fabricated with a d-spacing of 1.59 nm and 30 bilayers has a smaller interface width (σ = 0.27 and 0.32 nm) than the conventional used Cr/Sc (σ = 0.28 and 0.47 nm). For V/Sc multilayer with 30 bilayers, the introduction of B 4 C barrier layers has little improvement on the interface structure. As the number of bilayers increasing to 400, the growth morphology and microstructure of the V/Sc layers evolves with slightly increased crystallization. Nevertheless, the surface roughness remains to be 0.25 nm. A maximum soft X-ray reflectance of 18.4% is measured at λ = 3.129 nm at 9° off-normal incidence using the 400-bilayers V/Sc multilayer. According to the fitted model, an s-polarization reflectance of 5.2% can also be expected at λ = 2.425 nm under 40° incidence. Based on the promising experimental results, further improvement of the reflectance can be achieved by using a more stable deposition system, exploring different interface engineering methods and so on.

  7. Postprandial glucose response to selected tropical fruits in normal glucose-tolerant Nigerians.

    Science.gov (United States)

    Edo, A; Eregie, A; Adediran, O; Ohwovoriole, A; Ebengho, S

    2011-01-01

    The glycemic response to commonly eaten fruits in Nigeria has not been reported. Therefore, this study assessed the plasma glucose response to selected fruits in Nigeria. Ten normal glucose-tolerant subjects randomly consumed 50 g carbohydrate portions of three fruits: banana (Musa paradisiaca), pineapple (Ananus comosus), and pawpaw (Carica papaya), and a 50-g glucose load at 1-week intervals. Blood samples were collected in the fasting state and half-hourly over a 2-h period post-ingestion of the fruits or glucose. The samples were analyzed for plasma glucose concentrations. Plasma glucose responses were assessed by the peak plasma glucose concentration, maximum increase in plasma glucose, 2-h postprandial plasma glucose level, and incremental area under the glucose curve and glycemic index (GI). The results showed that the blood glucose response to these three fruits was similar in terms of their incremental areas under the glucose curve, maximum increase in plasma glucose, and glycemic indices (GIs). The 2-h postprandial plasma glucose level of banana was significantly higher than that of pineapple, P < 0.025. The mean ± SEM GI values were as follows: pawpaw; 86 ± 26.8%; banana, 75.1 ± 21.8%; pineapple, 64.5 ± 11.3%. The GI of glucose is taken as 100. The GI of pineapple was significantly lower than that of glucose (P < 0.05). Banana, pawpaw, and pineapple produced a similar postprandial glucose response. Measured portions of these fruits may be used as fruit exchanges with pineapple having the most favorable glycemic response.

  8. Bulk viscosity in 2SC quark matter

    International Nuclear Information System (INIS)

    Alford, Mark G; Schmitt, Andreas

    2007-01-01

    The bulk viscosity of three-flavour colour-superconducting quark matter originating from the nonleptonic process u + s ↔ u + d is computed. It is assumed that up and down quarks form Cooper pairs while the strange quark remains unpaired (2SC phase). A general derivation of the rate of strangeness production is presented, involving contributions from a multitude of different subprocesses, including subprocesses that involve different numbers of gapped quarks as well as creation and annihilation of particles in the condensate. The rate is then used to compute the bulk viscosity as a function of the temperature, for an external oscillation frequency typical of a compact star r-mode. We find that, for temperatures far below the critical temperature T c for 2SC pairing, the bulk viscosity of colour-superconducting quark matter is suppressed relative to that of unpaired quark matter, but for T ∼> T c /30 the colour-superconducting quark matter has a higher bulk viscosity. This is potentially relevant for the suppression of r-mode instabilities early in the life of a compact star

  9. BOOK REVIEW: Assessing Sc1 for GCSE

    Science.gov (United States)

    Reynolds, H.

    2000-01-01

    It is well known that investigations that `fit' the National Curriculum or examination board criteria are few in number. The fair testing emphasis means that pupils all over the country are finding out what affects the rate of a chemical reaction, the rate of photosynthesis or, in the case of Physics, the resistance of a wire. This book focuses on nine of the most common Sc1 investigations and how to prepare for them, manage and assess them. The author, a GCSE examiner, has turned his expertise into a handbook for improving Sc1 performance in the classroom. He has produced a book that would be extremely useful to both newly qualified teachers and experienced teachers. The first aim of the book, however, is to explain the requirements of Sc1. This is done comprehensively with examples of what the jargon means in practice. By breaking down the elements of planning, obtaining evidence, analysing evidence and evaluating, it is easy to see the subtleties of the mark descriptors. At first glance there seems to be little difference between the type of scientific knowledge needed for planning at level 6 and level 8. However, the level 8 statement specifies `detailed' scientific knowledge and understanding, which would mean a student should use equations from physics or symbolic chemical equations to support their arguments. One of the most useful sections in the book details the marking problems that can arise with some investigations. For example, in an investigation into electromagnets it is difficult for students to provide sufficient relevant scientific theory to satisfy the requirements of planning at level 6. One of the problems with Sc1 is that certain requirements, such as graph plotting, are difficult for many students. This book provides exercises that can be given to students to improve those skills. Each of the nine investigations is covered in great detail. Each investigation begins with an introduction detailing the rationale for choosing it, whether students

  10. Luminescence of La3+ and Sc3+ impurity centers in YAlO3 single-crystalline films

    International Nuclear Information System (INIS)

    Zorenko, Yu.; Gorbenko, V.; Voznyak, T.; Zorenko, T.; Nikl, M.; Nejezchleb, K.

    2008-01-01

    The luminescence of La Y 3+ and Sc Y 3+ and Sc Al 3+ centers created by lanthanum and scandium ions at Y 3+ and Al 3+ cation sites of YAlO 3 perovskite lattice was investigated. The features of emission of excitons localized at the mentioned centers in YAlO 3 :La and YAlO 3 :Sc single-crystalline films were analyzed by means of time-resolved emission spectroscopy and luminescence decay kinetics measurements under excitation by synchrotron radiation at 9 and 300 K

  11. Pt Skin Versus Pt Skeleton Structures of Pt3Sc as Electrocatalysts for Oxygen Reduction

    DEFF Research Database (Denmark)

    Johansson, Tobias Peter; Ulrikkeholm, Elisabeth Therese; Hernandez-Fernandez, Patricia

    2014-01-01

    . The development of new materials for this reaction is essential in order to increase the overall effeciency of the fuel cell. Herein, we study the effect of ultra high vacuum annealing on the structure and activity of polycrystalline Pt3Sc. Upon annealing in ultra high vacuum a Pt overlayer is formed......, relative to Pt(111), consistent with the CO adsorption energies calculated using density functional theory calculations. Exposing the annealed Pt3Sc sample to 200 mbar O2 at room temperature results in similar to 14 % Sc oxide as measured by X-ray photoelectron spectroscopy. Electrochemical testing...

  12. Properties of the low-lying negative parity states in 45Sc

    International Nuclear Information System (INIS)

    Chevallier, J.; Haas, B.; Schulz, N.; Toulemonde, M.

    1975-01-01

    The electromagnetic decay of negative parity states in 45 Sc up to an excitation energy of 2107keV have been investigated via the 42 Ca(α,pγ) 45 Sc reaction at a bombarding energy of 10.5MeV. Spin and lifetime of the levels as well as branching and mixing ratios of their decay γ-rays have been obtained from proton-gamma angular correlation measurements. Calculations based on the strong coupling model have been performed. The results are compared with experiment [fr

  13. Results on testing pilot industrial batch of SC magnets for the UNK

    International Nuclear Information System (INIS)

    Ageev, A.I.; Andreev, N.I.; Balbekov, V.I.; Chirkov, P.N.; Dolzhenkov, V.I.; Gertsev, K.F.; Gridasov, V.I.; Myznikov, K.P.; Smirnov, N.L.; Sychev, V.A.

    1992-01-01

    IHEP has developed and studied the superconducting dipoles and quadrupoles of the regular part of the UNK main ring which satisfy the requirements imposed on them. The pilot-industrial batch of the UNK SC magnets has been produced now. The reproducibility of the magnet characteristics is studied and the mass production technology is optimized with this batch. The results of the cryogenic tests and the magnetic field measurements for the UNK SC dipoles of the pilot-industrial batch are presented. (author) 5 refs.; 6 figs.; 1 tab

  14. A comprehensive framework for optimising the effects of inverse logistics practices in SC sustainability

    Directory of Open Access Journals (Sweden)

    Cristina López Vargas

    2017-06-01

    Full Text Available With growing sustainability concern in mind, firms seek to implement reverse logistic systems in their operations. However, if these practices were not properly implemented, they would be costly and even ineffective. In order to guide company efforts, the present study provide a comprehensive framework based on two dimensions. On one hand, it suits a reverse logistic management model stage-by-stage. On the other hand, the framework brings together concrete measures to optimize SC sustainability from three perspectives: operative, economical and environmental. The proposed framework thus allow to balance reverse logistic practices and SC sustainability. Furthermore, we validated it by analysing six real case in different industries. Findings highlight how reverse logistic activities may improve each SC sustainability dimension.

  15. Magnetic anisotropy in the incommensurate ScFe{sub 4}Al{sub 8} system

    Energy Technology Data Exchange (ETDEWEB)

    Rećko, K., E-mail: k.recko@uwb.edu.pl [Faculty of Physics, University of Białystok, K. Ciołkowskiego 1L, 15-245 Białystok (Poland); Dobrzyński, L. [National Centre for Nuclear Research, A. Soltan 7, 05-400 Otwock-Świerk (Poland); Waliszewski, J.; Szymański, K. [Faculty of Physics, University of Białystok, K. Ciołkowskiego 1L, 15-245 Białystok (Poland)

    2015-08-15

    Neutron scattering and magnetization data are used for estimation of the spin ordering in ScFe{sub 4}Al{sub 8}. Results of experimental measurements are compared with the ground state configurations obtained by simulated annealing algorithms. The origins of the magnetocrystalline anisotropy of the scandium intermetallic alloy and the conditions of the coexistence of two different magnetic modulations as a function of the exchange integrals are discussed. The influence of the dipolar interactions for the noncollinearity and incommensurability in ScFe{sub 4}Al{sub 8} was determined. - Highlights: • We found dipolar and DM interactions as the anisotropy origins of 3d–3d–3p alloy. • We covered the explanation of incommensurability and noncollinearity of ScFe{sub 4}Al{sub 8}. • We discussed the magnetism resulting from competitiveness of exchange effects.

  16. Substance P Differentially Modulates Firing Rate of Solitary Complex (SC) Neurons from Control and Chronic Hypoxia-Adapted Adult Rats

    Science.gov (United States)

    Nichols, Nicole L.; Powell, Frank L.; Dean, Jay B.; Putnam, Robert W.

    2014-01-01

    NK1 receptors, which bind substance P, are present in the majority of brainstem regions that contain CO2/H+-sensitive neurons that play a role in central chemosensitivity. However, the effect of substance P on the chemosensitive response of neurons from these regions has not been studied. Hypoxia increases substance P release from peripheral afferents that terminate in the caudal nucleus tractus solitarius (NTS). Here we studied the effect of substance P on the chemosensitive responses of solitary complex (SC: NTS and dorsal motor nucleus) neurons from control and chronic hypoxia-adapted (CHx) adult rats. We simultaneously measured intracellular pH and electrical responses to hypercapnic acidosis in SC neurons from control and CHx adult rats using the blind whole cell patch clamp technique and fluorescence imaging microscopy. Substance P significantly increased the basal firing rate in SC neurons from control and CHx rats, although the increase was smaller in CHx rats. However, substance P did not affect the chemosensitive response of SC neurons from either group of rats. In conclusion, we found that substance P plays a role in modulating the basal firing rate of SC neurons but the magnitude of the effect is smaller for SC neurons from CHx adult rats, implying that NK1 receptors may be down regulated in CHx adult rats. Substance P does not appear to play a role in modulating the firing rate response to hypercapnic acidosis of SC neurons from either control or CHx adult rats. PMID:24516602

  17. Substance P differentially modulates firing rate of solitary complex (SC neurons from control and chronic hypoxia-adapted adult rats.

    Directory of Open Access Journals (Sweden)

    Nicole L Nichols

    Full Text Available NK1 receptors, which bind substance P, are present in the majority of brainstem regions that contain CO2/H(+-sensitive neurons that play a role in central chemosensitivity. However, the effect of substance P on the chemosensitive response of neurons from these regions has not been studied. Hypoxia increases substance P release from peripheral afferents that terminate in the caudal nucleus tractus solitarius (NTS. Here we studied the effect of substance P on the chemosensitive responses of solitary complex (SC: NTS and dorsal motor nucleus neurons from control and chronic hypoxia-adapted (CHx adult rats. We simultaneously measured intracellular pH and electrical responses to hypercapnic acidosis in SC neurons from control and CHx adult rats using the blind whole cell patch clamp technique and fluorescence imaging microscopy. Substance P significantly increased the basal firing rate in SC neurons from control and CHx rats, although the increase was smaller in CHx rats. However, substance P did not affect the chemosensitive response of SC neurons from either group of rats. In conclusion, we found that substance P plays a role in modulating the basal firing rate of SC neurons but the magnitude of the effect is smaller for SC neurons from CHx adult rats, implying that NK1 receptors may be down regulated in CHx adult rats. Substance P does not appear to play a role in modulating the firing rate response to hypercapnic acidosis of SC neurons from either control or CHx adult rats.

  18. Final Technical Report for Award SC0008613

    Energy Technology Data Exchange (ETDEWEB)

    Knopf, Daniel A. [Stony Brook Univ., NY (United States)

    2017-04-05

    Discovering how aerosol particles, present in the atmosphere in sizes of a few nanometers to hundred micrometers, initiate ice crystal formation represents a great challenge. Atmospheric ice nucleation is important because ice crystals alter the radiative properties of clouds and thus climate, and impact precipitation and thus the hydrological cycle. The difficulty in predicting atmospheric ice formation is attributable at least in part, to the diversity of ice nucleation pathways, the physical and chemical complexity of the ice nucleating particles (INPs), and the relatively small numbers of INPs (compared with all other aerosol particles), sometimes less than one in 100000. These factors in turn makes constraining ice nucleation parameterizations for modeling applications challenging. The majority of airborne particles are known to be organic in nature or contain organic biogenic material. The presence of organic material adds to the complexity of the particles and therefore the predictability of ice nucleation events since the organic species can display different phase states, e.g. liquid or solid, in response to temperature and humidity. The award DE-SC0008613 to PI Prof. Daniel Knopf at Stony Brook University, “Relating the Chemical and Physical Properties of Aerosols to the Water Uptake and Ice Nucleation Potential of Particles Collected During the Carbonaceous Aerosols and Radiative Effects Study (CARES)”, allowed examination of laboratory generated aerosol particles and field-collected particles for their propensity to nucleate ice under typical tropospheric conditions and relate ice nucleation to the physicochemical properties of the particles including their morphology and chemical composition. This in turn allowed for development of ice nucleation parameterizations for implementation in cloud models. The award resulted in 10 peer-reviewed publications and more than 20 seminar and conference presentations. We demonstrated that the rate of immersion

  19. Characterizing Organic Aerosol Processes and Climatically Relevant Properties via Advanced and Integrated Analyses of Aerosol Mass Spectrometry Datasets from DOE Campaigns and ACRF Measurements. Final report for DE-SC0007178

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qi [Univ. of California, Davis, CA (United States)

    2017-05-21

    Organic aerosols (OA) are an important but poorly characterized component of the earth’s climate system. Enormous complexities commonly associated with OA composition and life cycle processes have significantly complicated the simulation and quantification of aerosol effects. To unravel these complexities and improve understanding of the properties, sources, formation, evolution processes, and radiative properties of atmospheric OA, we propose to perform advanced and integrated analyses of multiple DOE aerosol mass spectrometry datasets, including two high-resolution time-of-flight aerosol mass spectrometer (HR-AMS) datasets from intensive field campaigns on the aerosol life cycle and the Aerosol Chemical Speciation Monitor (ACSM) datasets from long-term routine measurement programs at ACRF sites. In this project, we will focus on 1) characterizing the chemical (i.e., composition, organic elemental ratios), physical (i.e., size distribution and volatility), and radiative (i.e., sub- and super-saturated growth) properties of organic aerosols, 2) examining the correlations of these properties with different source and process regimes (e.g., primary, secondary, urban, biogenic, biomass burning, marine, or mixtures), 3) quantifying the evolutions of these properties as a function of photochemical processing, 4) identifying and characterizing special cases for important processes such as SOA formation and new particle formation and growth, and 5) correlating size-resolved aerosol chemistry with measurements of radiative properties of aerosols to determine the climatically relevant properties of OA and characterize the relationship between these properties and processes of atmospheric aerosol organics. Our primary goal is to improve a process-level understanding of the life cycle of organic aerosols in the Earth’s atmosphere. We will also aim at bridging between observations and models via synthesizing and translating the results and insights generated from this

  20. Final Scientific Report: DE-SC0002194

    Energy Technology Data Exchange (ETDEWEB)

    Seidler, Gerald [Univ. of Washington, Seattle, WA (United States)

    2017-04-07

    We provide the final scientific report for DE-SC0002194. During the term of this grant, 28 publications spanning a variety of topics were addressed under the rubric of advanced x-ray methods and their application to extreme conditions of time-resolution or x-ray intensities. Notable accomplishments include a new observation of XANES features associated with f-shell reconfiguration in lanthanides, size-dependent x-ray heating effects under XFEL illumination conditions, theoretical development of improved treatments of inelastic x-ray scattering for 'warm dense matter' conditions, and several new instrument develop efforts for atomic, molecular, and condensed phase studies in the lab and at major facility lightsources.

  1. The SC State NSF PAARE Program

    Science.gov (United States)

    Walter, Donald; Ajello, Marco; Brittain, Sean; Cash, Jennifer; Fogle, Bryan; Hartmann, Dieter; Ho, Shirley; Howell, Steve; King, Jeremy; Leising, Mark; Smith, Daniel

    2018-01-01

    We report on the activities of our NSF PAARE program during Year 3 of the project. Our partnership under this award includes South Carolina State University (a Historically Black College/University), Clemson University (a Ph.D. granting institution) and individual investigators at NASA Ames and elsewhere. Our partnership with the Citizen CATE Experiment and involvement in the total solar eclipse which passed through our campus on August 21, 2017, will be discussed. The PAARE project continues to strengthen our partnership with Clemson. We are close to completing a memorandum of agreement between the two institutions that will allow for the seamless transfer of an undergraduate from SC State to Clemson’s graduate program in physics and astronomy. Additionally, we have worked together under the Citizen CATE project and through other research activities. SC State is a member of the National Astronomy Consortium (NAC) and participates through its faculty and undergraduates, one of whom (Wesley Red) is reporting on his summer internship at this conference. We also served as the state coordinator for South Carolina for the Citizen CATE Experiment. The August 21st path of totality crossed through our campus and the campus of our partner Clemson University. Additional colleges, universities and citizen scientist groups partnered with us to provide 7 sites of coverage across South Carolina from the foothills of the Appalachian mountains to the Atlantic Ocean near the site of departure of the shadow from the continental U.S. Support for this work includes our NSF PAARE award AST-1358913 as well as resources and support provided by Clemson University and the National Optical Astronomy Observatory. CATE work has been supported by NASA SMD award NNX16AB92A to the National Solar Observatory. Additional details can be found at: http://physics.scsu.edu

  2. Thermal neutron capture and resonance integral cross sections of {sup 45}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Van Do, Nguyen; Duc Khue, Pham; Tien Thanh, Kim [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Thi Hien, Nguyen [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Guinyun, E-mail: gnkim@knu.ac.kr [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Kwangsoo [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Shin, Sung-Gyun; Cho, Moo-Hyun [Department of Advanced Nuclear Engineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Lee, Manwoo [Research Center, Dongnam Institute of Radiological and Medical Science, Busan 619-953 (Korea, Republic of)

    2015-11-01

    The thermal neutron cross section (σ{sub 0}) and resonance integral (I{sub 0}) of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been measured relative to that of the {sup 197}Au(n,γ){sup 198}Au reaction by means of the activation method. High-purity natural scandium and gold foils without and with a cadmium cover of 0.5 mm thickness were irradiated with moderated pulsed neutrons produced from the Pohang Neutron Facility (PNF). The induced activities in the activated foils were measured with a high purity germanium (HPGe) detector. In order to improve the accuracy of the experimental results the counting losses caused by the thermal (G{sub th}) and resonance (G{sub epi}) neutron self-shielding, the γ-ray attenuation (F{sub g}) and the true γ-ray coincidence summing effects were made. In addition, the effect of non-ideal epithermal spectrum was also taken into account by determining the neutron spectrum shape factor (α). The thermal neutron cross-section and resonance integral of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been determined relative to the reference values of the {sup 197}Au(n,γ){sup 198}Au reaction, with σ{sub o,Au} = 98.65 ± 0.09 barn and I{sub o,Au} = 1550 ± 28 barn. The present thermal neutron cross section has been determined to be σ{sub o,Sc} = 27.5 ± 0.8 barn. According to the definition of cadmium cut-off energy at 0.55 eV, the present resonance integral cross section has been determined to be I{sub o,Sc} = 12.4 ± 0.7 barn. The present results are compared with literature values and discussed.

  3. Attenuation of morphine withdrawal signs, blood cortisol and glucose level with forced exercise in comparison with clonidine

    Directory of Open Access Journals (Sweden)

    Majid Motaghinejad

    2014-01-01

    Full Text Available Background: Morphine withdrawal usually results in undesired outcomes , despite partial benefits of alternative medication such as methadone, because of the lack of mental sedation during the withdrawal period, may not lead to the desired result. In this study, forced exercise by treadmill is used to manage morphine dependence in animal model. Materials and Methods: Forty adult male mice were divided into 5 groups, from which 4 groups became dependent by increasing daily doses of morphine for 6 days (20-45 mg/kg, SC. Afterwards, the animals were treated for 21 days by either of the following protocol: Positive control (dependent received once daily 45 mg/kg of morphine sulfate (SC for 21 day, group under treatment by clonidine (0.4 mg/kg, SC for 21 day group under treatment by forced exercise by treadmill for 21 day, group under treatment by combination of clonidine (0.4 mg/kg, SC and forced exercise by treadmill for 21day and the negative control group(independent received saline injection like other groups. Each of this administration was injected at 8 AM. Finally, in the test day (day 28, all animals received a single dose of naloxone (3 mg/kg, SC at 8 AM and then were observed for withdrawal signs, and Total Withdrawal Score (TWS was determined as described previously. After withdrawal sign evaluation for evaluation of stress level of dependent mice, blood cortisol and glucose level were measured in non-fasting situations well. Results: This study showed that TWS significantly decreased in all treatment groups in comparison with positive control group (P < 0.001. Moreover, blood cortisol and glucose level significantly decreased in group under treatment by clonidine (0.4 mg/kg and group under treatment by combination of clonidine (0.4 mg/kg and forced exercise by treadmill groups in comparison with control positive (dependent (P < 0.05. Conclusion: This study suggested that forced exercise can be useful as adjunct therapy in dependent people

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ... you should check and what your blood glucose levels should be. Checking your blood and then treating ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... blood glucose High levels of sugar in the urine Frequent urination Increased thirst Part of managing your ... glucose is above 240 mg/dl, check your urine for ketones. If you have ketones, do not ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... can often lower your blood glucose level by exercising. However, if your blood glucose is above 240 ... ketones. If you have ketones, do not exercise. Exercising when ketones are present may make your blood ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High ... We Are Research Leaders We Support Your Doctor Student Resources Patient Access to Research Research Resources Practice ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get ... the technical term for high blood glucose (blood sugar). High blood glucose happens when the body has ...

  11. Glucose in vaginal secretions before and after oral glucose tolerance testing in women with and without recurrent vulvovaginal candidiasis.

    Science.gov (United States)

    Ehrström, Sophia; Yu, Anna; Rylander, Eva

    2006-12-01

    To measure the change of glucose in vaginal secretions during glucose tolerance testing in women with recurrent vulvovaginal candidiasis and in healthy control subjects. Thirty-eight women with recurrent vulvovaginal candidiasis and 45 healthy, age-matched controls completed a health questionnaire regarding general and gynecologic health and food and alcohol habits. They all underwent an oral glucose tolerance test and a vaginal examination. Vaginal secretion was collected from the proximal part of the vagina. Glucose in plasma and in vaginal secretions were measured at fasting and after 2 hours and analyzed with the hexokinase method. A sample size analysis showed that the number of subjects included in the study was sufficient for a beta value of 0.80, at the significance level of alpha=.05, at a difference in glucose in vaginal secretions of 30% after oral glucose tolerance test. In healthy women, the median level of glucose in vaginal secretions was 5.2 mM before and 3.7 mM after oral glucose tolerance test, and plasma glucose was 5.0 mM before and 5.8 mM after oral glucose tolerance test. No significant difference was seen regarding change of glucose level in vaginal secretions and plasma glucose after testing, compared with before oral glucose tolerance testing. There were no differences between women with recurrent vulvovaginal candidiasis and control subjects regarding change in glucose level in vaginal secretions or in plasma during oral glucose tolerance test. II-2.

  12. Genetic Association Analysis of Fasting and 1- and 2-Hour Glucose Tolerance Test Data Using a Generalized Index of Dissimilarity Measure for the Korean Population

    Directory of Open Access Journals (Sweden)

    Jaeyong Yee

    2016-12-01

    Full Text Available Glucose tolerance tests have been devised to determine the speed of blood glucose clearance. Diabetes is often tested with the standard oral glucose tolerance test (OGTT, along with fasting glucose level. However, no single test may be sufficient for the diagnosis, and the World Health Organization (WHO/International Diabetes Federation (IDF has suggested composite criteria. Accordingly, a single multi-class trait was constructed with three of the fasting phenotypes and 1- and 2-hour OGTT phenotypes from the Korean Association Resource (KARE project, and the genetic association was investigated. All of the 18 possible combinations made out of the 3 sets of classification for the individual phenotypes were taken into our analysis. These were possible due to a method that was recently developed by us for estimating genomic associations using a generalized index of dissimilarity. Eight single-nucleotide polymorphisms (SNPs that were found to have the strongest main effect are reported with the corresponding genes. Four of them conform to previous reports, located in the CDKAL1 gene, while the other 4 SNPs are new findings. Two-order interacting SNP pairs of are also presented. One pair (rs2328549 and rs6486740 has a prominent association, where the two single-nucleotide polymorphism locations are CDKAL1 and GLT1D1. The latter has not been found to have a strong main effect. New findings may result from the proper construction and analysis of a composite trait.

  13. Uptake of 13C-glucose by cell suspensions of carrot (Daucus carota) measured by in vivo NMR: Cycling of triose, pentose- and hexose-phosphates

    NARCIS (Netherlands)

    Krook, J.; Vreugdenhil, D.; Dijkema, C.; Plas, van der L.H.W.

    2000-01-01

    After a lag phase of 2 days, batch-grown cells of carrot (Daucus carota L.) cv. Flakkese entered the exponential growth phase and started to accumulate sucrose and hexoses. Short-term feeding 13C-glucose in this period resulted in only minor labelling of sucrose or fructose. CO2 production from

  14. Triglyceride glucose index as a surrogate measure of insulin sensitivity in obese adolescents with normoglycemia, prediabetes, and type 2 diabetes mellitus: Comparison with the hyperinsulinemic–euglycemic clamp

    Science.gov (United States)

    There is a need for simple surrogate estimates of insulin sensitivity in epidemiological studies of obese youth because the hyperinsulinemic-euglycemic clamp is not feasible on a large scale. Objectives: (i) To examine the triglyceride glucose (TyG) index (Ln[fasting triglycerides (mg/dL)'×'fasting ...

  15. Poly(3,4-ethylenedioxythiophene)-based glucose biosensors

    NARCIS (Netherlands)

    Kros, A.; Hövell, W.F.M. van; Sommerdijk, N.A.J.M.; Nolte, R.J.M.

    2001-01-01

    Amperometric biosensors for the recognition of glucose oxidase (GOx) based on poly(3,4-ethylenedioxythiophene) (PEDOT) were fabricated for the first time. The resulting biosensor has potential applications for long-term glucose measurements.

  16. Modelling glucose and water dynamics in human skin

    NARCIS (Netherlands)

    Groenendaal, W.; Schmidt, K.H.; Basum, von G.; Riel, van N.A.W.; Hilbers, P.A.J.

    2008-01-01

    Background: Glucose is heterogeneously distributed in the different physiological compartments in the human skin. Therefore, for the development of a noninvasive measurement method, both a good quantification of the different compartments of human skin and an understanding of glucose transport

  17. Effect of Global ATGL Knockout on Murine Fasting Glucose Kinetics

    NARCIS (Netherlands)

    Coelho, M.; Nunes, P.; Mendes, V.M.; Manadas, B.; Heerschap, A.; Jones, J.G.

    2015-01-01

    Mice deficient in adipose triglyceride lipase (ATGL(-/-)) present elevated ectopic lipid levels but are paradoxically glucose-tolerant. Measurement of endogenous glucose production (EGP) and Cori cycle activity provide insights into the maintenance of glycemic control in these animals. These

  18. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  19. [Blood glucose self monitoring].

    Science.gov (United States)

    Wascher, Thomas C; Stechemesser, Lars

    2016-04-01

    Self monitoring of blood glucose contributes to the integrated management of diabetes mellitus. It, thus, should be available for all patients with diabetes mellitus type-1 and type-2. Self monitoring of blood glucose improves patients safety, quality of life and glucose control. The current article represents the recommendations of the Austrian Diabetes Association for the use of blood glucose self monitoring according to current scientific evidence.

  20. Indomethacin stimulates basal glucose production in humans without changes in concentrations of glucoregulatory hormones

    NARCIS (Netherlands)

    Corssmit, E. P.; Romijn, J. A.; Endert, E.; Sauerwein, H. P.

    1993-01-01

    1. To investigate whether indomethacin affects basal glucose production, we measured hepatic glucose production in six healthy postabsorptive subjects on two occasions: once after administration of indomethacin (150 mg orally) and once after administration of placebo. 2. Glucose production was

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Carbohydrate Counting Make Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type ... Checking Your Blood Glucose A1C and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... how often you should check and what your blood glucose levels should be. Checking your blood and then treating ... I Treat Hyperglycemia? You can often lower your blood glucose level by exercising. However, if your blood glucose is ...

  3. Toxicity, tissue distribution and excretion of 46ScCl3 and 46Sc-EDTA in mice

    International Nuclear Information System (INIS)

    Lachine, E.E.; Noujaim, A.A.; Ediss, C.; Wiebe, L.I.

    1976-01-01

    The acute toxicity, differential distribution in tissue, and elimination of ScCl 3 , 46 ScCl 3 , Sc-EDTA and 46 Sc-EDTA, in mice, has been investigated. The LD 50 sup(24hr) doses for ScCl 3 were 440 and 24 mg kg -1 respectively after intraperitioneal and intravenous injection, and 720 and 108 mg kg -1 respectively for Sc-EDTA. 46 ScCl 3 was extensively deposited in the liver and the spleen. 46 Sc-EDTA was rapidly taken up by the kidney with subsequent elimation via the urine. While-body desaturation kinetics for 46 Sc-EDTA were found to fit a three compartmental model. The fast elimination phase (T1/2 = 12.75 min; K = 0.05540 min -1 ) accounted for 74.6% of the dose; the intermediate phase (T1/2 = 40.2 min; K = 0.01722 min -1 ) for 21.8%, and the slow (T1/2 = 5351 min; K = 0.00013 min -1 ) for 3.6% of the dose. (author)

  4. Glucose-induced insulin resistance of skeletal-muscle glucose transport and uptake

    DEFF Research Database (Denmark)

    Richter, Erik; Hansen, B F; Hansen, S A

    1988-01-01

    in the presence of glucose and insulin. The data indicate that exposure to a moderately increased glucose concentration (12 mM) leads to rapidly developing resistance of skeletal-muscle glucose transport and uptake to maximal insulin stimulation. The effect of glucose is enhanced by simultaneous insulin exposure......, whereas exposure for 5 h to insulin itself does not cause measurable resistance to maximal insulin stimulation.......The ability of glucose and insulin to modify insulin-stimulated glucose transport and uptake was investigated in perfused skeletal muscle. Here we report that perfusion of isolated rat hindlimbs for 5 h with 12 mM-glucose and 20,000 microunits of insulin/ml leads to marked, rapidly developing...

  5. IEC SC15E: Report on liaison activities of CIGRÉ-SC15

    DEFF Research Database (Denmark)

    Henriksen, Mogens

    2000-01-01

    WG’s activities under CIGRÉ SC15:WG 15.01 - Fluid impregnated systems.WG 15.02 - Dielectric Liquids.WG 15.03 - Gas Insulation.WG 15.04 - Outdoor Insulation.WG 15.05 - Capacitors.WG 15.07 - Solid Insulating Materials for Rotating Machines.WG 15/33.08 - Insulation Monitoring and Life Estimation. WG...

  6. Cyclotron production of {sup 44}Sc for clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Krajewski, S.; Bilewicz, A. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland); Cydzik, I. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland); European Commission Joint Research Center, Ispra (Italy). Inst. for Health and Consumer Protection; Warsaw Univ. (Poland). Heavy Ion Lab.; Abbas, K. [European Commission Joint Research Center, Ispra (Italy). Institute for Transuranium Elements; Bulgheroni, A.; Simonelli, F.; Holzwarth, U. [European Commission Joint Research Center, Ispra (Italy). Inst. for Health and Consumer Protection

    2013-08-01

    {sup 44} is a promising {beta}{sup +}-emitter for molecular imaging with intermediate half-life of 4 h. Due to the chemical similarity of Sc{sup 3+} to the Lu{sup 3+} and Y{sup 3+} cations, {sup 44}Sc-DOTA bioconjugates are expected to demonstrate similar properties in vivo as the {sup 177}Lu- and {sup 90}Y-bioconjugates, what is important in planning the radionuclide therapy. {sup 44}Sc can be obtained from the {sup 44}Ti/{sup 44}Sc generator. An alternative method for {sup 44}Sc production can be the irradiation of {sup 44}Ca target at small cyclotrons. The aim of our work was to optimize the parameters of {sup 44}CaCO{sub 3} irradiation and to develop a simple procedure for {sup 44}Sc separation from the calcium target. For optimization study, {sup 44}CaCO{sub 3} targets were irradiated by protons in the energy range of 5.6-17.5 MeV with 9 MeV being found to be the best energy for {sup 44}Ca irradiations. A simple and fast separation procedure of {sup 44}Sc from calcium target was developed using chelating resin Chelex 100. DOTATATE conjugate was successfully radiolabelled with high yield at elevated temperature using the produced {sup 44}Sc. While {sup 44}CaCO{sub 3} is relatively expensive, the cost of {sup 44}Sc-DOTATATE production can be reduced by target recovery. Due to low proton energy required to produce GBq activity level of {sup 44}Sc, the availability of {sup 44}Sc radioisotope could be enhanced to open new opportunities for applications in medical imaging. (orig.)

  7. Glucose metabolism disorder in obese children assessed by continuous glucose monitoring system.

    Science.gov (United States)

    Zou, Chao-Chun; Liang, Li; Hong, Fang; Zhao, Zheng-Yan

    2008-02-01

    Continuous glucose monitoring system (CGMS) can measure glucose levels at 5-minute intervals over a few days, and may be used to detect hypoglycemia, guide insulin therapy, and control glucose levels. This study was undertaken to assess the glucose metabolism disorder by CGMS in obese children. Eighty-four obese children were studied. Interstitial fluid (ISF) glucose levels were measured by CGMS for 24 hours covering the time for oral glucose tolerance test (OGTT). Impaired glucose tolerance (IGT), impaired fasting glucose (IFG), type 2 diabetic mellitus (T2DM) and hypoglycemia were assessed by CGMS. Five children failed to complete CGMS test. The glucose levels in ISF measured by CGMS were highly correlated with those in capillary samples (r=0.775, Pobese children who finished the CGMS, 2 children had IFG, 2 had IGT, 3 had IFG + IGT, and 2 had T2DM. Nocturnal hypoglycemia was noted during the overnight fasting in 11 children (13.92%). Our data suggest that glucose metabolism disorder including hyperglycemia and hypoglycemia is very common in obese children. Further studies are required to improve the precision of the CGMS in children.

  8. Piezoelectric characterization of Sc0.26Al0.74N layers on Si (001) substrates

    Science.gov (United States)

    Sinusía Lozano, M.; Pérez-Campos, A.; Reusch, M.; Kirste, L.; Fuchs, Th; Žukauskaitė, A.; Chen, Z.; Iriarte, G. F.

    2018-03-01

    Scandium aluminum nitride (ScAlN) films have been synthesized by pulsed-DC reactive magnetron sputtering. The degree of c-axis orientation as well as piezoelectric characteristics of the Sc0.26Al0.74N thin films grown on Si (001) at various discharge powers and processing pressures values have been investigated. According to x-ray diffraction (XRD) measurements, the texture of the as-grown Sc0.26Al0.74N thin films becomes more prominent in the [0001]-direction at the highest target power (700 W) and at the lowest processing pressure (4 mTorr). The piezoelectric response, as determined by measuring the d33 piezoelectric constant, shows a maximum value of -12 pC/N also at 4 mTorr and 700 W, confirming a direct correlation between the d33 piezoelectric constant and the degree of orientation in the [0001]-direction. The atomic concentration of Sc and Al in the synthesized ScAlN thin film, determined by secondary ion mass spectroscopy (SIMS), reveals a Sc concentration lower than in the ScAl alloy target. The piezoresponse force microscopy (PFM) shows homogeneous polarity distribution with no inversion domains. The piezoelectric layers have been used to fabricate and measure surface acoustic wave (SAW) resonators on a Sc0.26Al0.74N/Si (001) bilayer system with resonance frequency of 1.4 GHz and coupling coefficient of 0.567. Such characteristic in the frequency response reveals the potential of these materials for advanced SAW devices in applications such as next generation (5 G) wireless communication systems.

  9. Non Invasive Glucose Monitoring System Using Nanosensors

    Directory of Open Access Journals (Sweden)

    Rajasekaran C.

    2016-03-01

    Full Text Available The most existing future technology is an outcome of the fields of computer science, electronics and Biology. Health inequalities have become the focus of a number of descriptive and analytical studies. One of the health related problem is diabetes. Diabetes at its serious stage leads to blindness. Monitoring glucose level in blood is one preventive measure to check diabetes. Increase in Glucose is a common risk factor which leads to hyperglycemia, Hypoglycemia, heart attack, stokes and aneurysms. A glucose monitoring system continuously measures and monitors the glucose level in a patient’s blood. Normal blood glucose level of human is 70-110 milligram/deciliter. The level is maintained by using the secretion of insulin inside the body. When the insulin level gets increased it leads to hyperglycemia, and hypoglycemia when the level gets decreased. Hyperglycemia disease includes cataract,edema, hypertension, polyuria and polydipsia. Hypoglycemaia disease includes confusion, giddiness, unconsciousness, coma and death. The proposed system finds a new way for measuring the glucose level. The work uses Nanopellets which measure’s the glucose level, when the glucose level gets increased or decreased, it will be automatically get monitored and processed using microcontroller (MSP430G2553. The information is then send to the doctor through GSM.

  10. Underestimation of glucose turnover corrected with high-performance liquid chromatography purification of [6-3H]glucose

    International Nuclear Information System (INIS)

    Schwenk, W.F.; Butler, P.C.; Haymond, M.W.; Rizza, R.A.

    1990-01-01

    We have recently reported that during infusion of commercially available [6-3H]glucose, a radioactive nonglucose contaminant may accumulate in plasma causing errors in the measurement of glucose turnover. To determine whether purification of this tracer by HPLC (high-performance liquid chromatography) before infusion would eliminate the contaminant in plasma and remove the underestimation of glucose turnover reported during hyperinsulinemia, four normal subjects each underwent two 5-h euglycemic clamps during infusion of insulin (1 mU.kg-1.min-1). Glucose turnover was measured with either commercially available [6-3H]glucose or with HPLC-purified [6-3H]glucose. HPLC analysis of samples from the clamps done with commercially available [6-3H]glucose showed that 9.7% of the infused tracer and 26% of the plasma glucose 3H radioactivity were contaminants. In contrast, no contaminant was observed in the plasma during infusion of HPLC-purified [6-3H]glucose. During the last hour of the clamp, mean glucose turnover using commercially available [6-3H]glucose was less (P less than 0.01) than the mean glucose infusion rate (7.6 +/- 0.3 vs. 10.5 +/- 0.3 mg.kg-1.min-1) yielding apparent negative (P less than 0.001) hepatic glucose release. In contrast, when HPLC-purified [6-3H]glucose was employed, glucose turnover equaled the glucose infusion rate (10.4 +/- 0.9 vs. 10.2 +/- 0.9 mg.kg-1.min-1) and hepatic glucose release was no longer negative. We conclude that removal of a tritiated nonglucose contaminant in [6-3H]glucose by HPLC yields correct estimations of glucose turnover at steady state

  11. Simultaneous measurement of neuronal and glial metabolism in rat brain in vivo using co-infusion of [1,6- 13C 2]glucose and [1,2- 13C 2]acetate

    Science.gov (United States)

    Deelchand, Dinesh K.; Nelson, Christopher; Shestov, Alexander A.; Uğurbil, Kâmil; Henry, Pierre-Gilles

    2009-02-01

    In this work the feasibility of measuring neuronal-glial metabolism in rat brain in vivo using co-infusion of [1,6- 13C 2]glucose and [1,2- 13C 2]acetate was investigated. Time courses of 13C spectra were measured in vivo while infusing both 13C-labeled substrates simultaneously. Individual 13C isotopomers (singlets and multiplets observed in 13C spectra) were quantified automatically using LCModel. The distinct 13C spectral pattern observed in glutamate and glutamine directly reflected the fact that glucose was metabolized primarily in the neuronal compartment and acetate in the glial compartment. Time courses of concentration of singly and multiply-labeled isotopomers of glutamate and glutamine were obtained with a temporal resolution of 11 min. Although dynamic metabolic modeling of these 13C isotopomer data will require further work and is not reported here, we expect that these new data will allow more precise determination of metabolic rates as is currently possible when using either glucose or acetate as the sole 13C-labeled substrate.

  12. Sc-Decorated WS_2 Nanoribbons as Hydrogen Storage Media

    International Nuclear Information System (INIS)

    Xu Bin; Wang Yu-Sheng; Zhang Jing; Song Na-Hong; Li Meng; Yi Lin

    2016-01-01

    The hydrogen storage behavior of Sc-decorated WS_2 monolayer and WS_2 nanoribbons is systematically studied by using first principles calculations based on the density functional theory. The present results indicate that an Sc-decorated WS_2 monolayer is not suitable for storing hydrogen due to the weak interaction between the monolayer WS_2 sheet and the Sc atoms. It is found that both the hybridization mechanism and the Coulomb attraction make the Sc atoms stably adsorb on the edges of WS_2 nanoribbons without clustering. The 2Sc/WS_2 NRs system can adsorb at most eight H_2 molecules with average adsorption energy of 0.20 eV/H_2. The results show that the desorption of H_2 is possible by lowering the pressure or by increasing the temperature. (paper)

  13. Age- and Gender-Specific Reference Intervals for Fasting Blood Glucose and Lipid Levels in School Children Measured With Abbott Architect c8000 Chemistry Analyzer

    OpenAIRE

    Tamimi, Waleed; Albanyan, Esam; Altwaijri, Yasmin; Tamim, Hani; Alhussein, Fahad

    2012-01-01

    Reference intervals for pubertal characteristics are influenced by genetic, geographic, dietary and socioeconomic factors. Therefore, the aim of this study was to establish age-specific reference intervals of glucose and lipid levels among local school children. This was cross-sectional study, conducted among Saudi school children. Fasting blood samples were collected from 2149 children, 1138 (53%) boys and 1011 (47%) girls, aged 6 to 18 years old. Samples were analyzed on the Architect c8000...

  14. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    Science.gov (United States)

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  15. Age- and Gender-Specific Reference Intervals for Fasting Blood Glucose and Lipid Levels in School Children Measured With Abbott Architect c8000 Chemistry Analyzer.

    Science.gov (United States)

    Tamimi, Waleed; Albanyan, Esam; Altwaijri, Yasmin; Tamim, Hani; Alhussein, Fahad

    2012-04-01

    Reference intervals for pubertal characteristics are influenced by genetic, geographic, dietary and socioeconomic factors. Therefore, the aim of this study was to establish age-specific reference intervals of glucose and lipid levels among local school children. This was cross-sectional study, conducted among Saudi school children. Fasting blood samples were collected from 2149 children, 1138 (53%) boys and 1011 (47%) girls, aged 6 to 18 years old. Samples were analyzed on the Architect c8000 Chemistry System (Abbott Diagnostics, USA) for glucose, cholesterol, triglycerides, HDL and LDL. Reference intervals were established by nonparametric methods between the 2.5th and 97.5th percentiles. Significant differences were observed between boys and girls for cholesterol and triglycerides levels in all age groups (P glucose levels except at age 12 to 13 years. Saudi children have comparable serum cholesterol levels than their Western counterparts. This may reflect changing dietary habits and increasing affluence in Saudi Arabia. Increased lipid screening is anticipated, and these reference intervals will aid in the early assessment of cardiovascular and diabetes risk in Saudi pediatric populations.

  16. Conditions With High Intracellular Glucose Inhibit Sensing Through Glucose Sensor Snf3 in Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Karhumaa, Kaisa; Wu, B.Q.; Kielland-Brandt, Morten

    2010-01-01

    as for amino acids. An alternating-access model of the function of transporter-like sensors has been previously suggested based on amino acid sensing, where intracellular ligand inhibits binding of extracellular ligand. Here we studied the effect of intracellular glucose on sensing of extracellular glucose...... through the transporter-like sensor Snf3 in yeast. Sensing through Snf3 was determined by measuring degradation of Mth1 protein. High intracellular glucose concentrations were achieved by using yeast strains lacking monohexose transporters which were grown on maltose. The apparent affinity...... of extracellular glucose to Snf3 was measured for cells grown in non-fermentative medium or on maltose. The apparent affinity for glucose was lowest when the intracellular glucose concentration was high. The results conform to an alternating-access model for transporter-like sensors. J. Cell. Biochem. 110: 920...

  17. Effective single chain antibody (scFv) concentrations in vivo via adenoviral vector mediated expression of secretory scFv

    NARCIS (Netherlands)

    Arafat, WO; Gomez-Navarro, J; Buchsbaum, DJ; Xiang, J; Casado, E; Barker, SD; Mahasreshti, PJ; Haisma, HJ; Barnes, MN; Siegal, GP; Alvarez, RD; Hemminki, A; Nettelbeck, DM; Curiel, DT

    Single chain antibodies (scFv) represent powerful interventional agents for the achievement of targeted therapeutics. The practical utility of these agents have been limited, however, by difficulties related to production of recombinant scFv and the achievement of effective and sustained levels of

  18. Hydride vapor phase epitaxy growth of GaN, InGaN, ScN, and ScAIN

    NARCIS (Netherlands)

    Bohnen, T.

    2010-01-01

    Chemical vapor deposition (CVD); hydride vapor phase epitaxy (HVPE); gallium nitride (GaN); indium gallium nitride (InGaN); scandium nitride (ScN); scandium aluminum nitride (ScAlN); semiconductors; thin films; nanowires; III nitrides; crystal growth - We studied the HVPE growth of different III

  19. Growth hormone receptor antagonist transgenic mice are protected from hyperinsulinemia and glucose intolerance despite obesity when placed on a HF diet.

    Science.gov (United States)

    Yang, Tianxu; Householder, Lara A; Lubbers, Ellen R; List, Edward O; Troike, Katie; Vesel, Clare; Duran-Ortiz, Silvana; Kopchick, John J; Berryman, Darlene E

    2015-02-01

    Reduced GH levels have been associated with improved glucose metabolism and increased longevity despite obesity in multiple mouse lines. However, one mouse line, the GH receptor antagonist (GHA) transgenic mouse, defies this trend because it has reduced GH action and increased adiposity, but glucose metabolism and life span are similar to controls. Slight differences in glucose metabolism and adiposity profiles can become exaggerated on a high-fat (HF) diet. Thus, in this study, male and female GHA and wild-type (WT) mice in a C57BL/6 background were placed on HF and low-fat (LF) diets for 11 weeks, starting at 10 weeks of age, to assess how GHA mice respond to additional metabolic stress of HF feeding. On a HF diet, all mice showed significant weight gain, although GHA gained weight more dramatically than WT mice, with males gaining more than females. Most of this weight gain was due to an increase in fat mass with WT mice increasing primarily in the white adipose tissue perigonadal depots, whereas GHA mice gained in both the sc and perigonadal white adipose tissue regions. Notably, GHA mice were somewhat protected from detrimental glucose metabolism changes on a HF diet because they had only modest increases in serum glucose levels, remained glucose tolerant, and did not develop hyperinsulinemia. Sex differences were observed in many measures with males reacting more dramatically to both a reduction in GH action and HF diet. In conclusion, our findings show that GHA mice, which are already obese, are susceptible to further adipose tissue expansion with HF feeding while remaining resilient to alterations in glucose homeostasis.

  20. Glucose turnover, gluconeogenesis from glycerol, and estimation of net glucose cycling in cancer patients

    International Nuclear Information System (INIS)

    Lundholm, K.; Edstroem, S.; Karlberg, I.; Ekman, L.; Schersten, T.

    1982-01-01

    A double isotope method was used in patients with progressive malignancy and in control patients to measure: glucose turnover, conversion rate of carbon skeleton of glycerol into glucose, and the interorgan cycling of glucose carbons (Cori-cycle plus alanine-glucose cycle). [U- 14 C]glycerol and [6- 3 H]glucose were given intravenously as a single dose injection. The time course of the specific radioactivities of [6- 3 H] and [U- 14 C]glucose was followed in blood. The pool size and the turnover rate of glucose were increased in the cancer group as compared with the control patients. The net recycling of glucose carbons was not increased in the cancer group, despite the increased turnover of glucose. The alterations in the metabolism of glucose did not correlate with the plasma levels of insulin or thyroid hormones (T4, T3, rT3) neither in the entire cancer group nor in those cancer patients who were repeatedly investigated at different intervals of time. The turnover rate of glucose in the cancer patients correlated inversely to their body weight index. The gluconeogenesis rate, given as the fractional conversion rate of the injected radioactive dose of [ 14 C]glycerol, or as mol glucose . kg body weight-1 . day-1, was increased in the cancer group, but still contributed only 3% of the glucose turnover rate in both cancer and control patients. We conclude that an increased gluconeogenesis from glycerol is not significant in terms of energy expenditure in patients with progressive malignancy, as has previously been concluded for the gluconeogenesis from alanine. It seems that increased turnover of glucose may contribute to inappropriately high energy expenditure in cancer patients

  1. Investigation of Sc(3) state in nonaqueous solutions by the 45Sc NMR method of high permission

    International Nuclear Information System (INIS)

    Buslaev, Yu.A.; Kirakosyan, G.A.; Tarasov, V.P.

    1980-01-01

    The ScCl 3 + CH 3 CN and ScCl 3 + KNCS + CH 3 CN solutions have been studied by a high-resolution NMR 45 Sc method. It has been estimated that in acetonitrile solutions, with competing ligands of Cl - and NCS - being available, hexacoordination Sc(3) complexes of various compositions are formed, and solvent molecules also take part in formation of the coordination sphere of scandium. Chemical shifts in NMR 45 Sc signals depend linearly on the number of chlor- or NCS - ions bound to scandium(3). This made it possible to determine the value of chemical shifts in signals of all 28 potential complexes formed in a system with three competing ligands

  2. Cyclotron production of {sup 43}Sc for PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Walczak, Rafał [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland); Krajewski, Seweryn [Synektik S.A., Research and Development Center, Warsaw (Poland); Szkliniarz, Katarzyna [Department of Nuclear Physics, University of Silesia, Katowice (Poland); Sitarz, Mateusz [Heavy Ion Laboratory, University of Warsaw, Warsaw (Poland); Abbas, Kamel [Nuclear Security Unit, Joint Research Centre, Institute for Transuranium Elements, European Commission, Ispra (Italy); Choiński, Jarosław; Jakubowski, Andrzej; Jastrzębski, Jerzy [Heavy Ion Laboratory, University of Warsaw, Warsaw (Poland); Majkowska, Agnieszka [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland); Simonelli, Federica [Nuclear Decommissioning Unit, Joint Research Centre, Ispra Site Management Directorate, European Commission, Ispra (Italy); Stolarz, Anna; Trzcińska, Agnieszka [Heavy Ion Laboratory, University of Warsaw, Warsaw (Poland); Zipper, Wiktor [Department of Nuclear Physics, University of Silesia, Katowice (Poland); Bilewicz, Aleksander [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland)

    2015-12-04

    Recently, significant interest in {sup 44}Sc as a tracer for positron emission tomography (PET) imaging has been observed. Unfortunately, the co-emission by {sup 44}Sc of high-energy γ rays (E{sub γ} = 1157, 1499 keV) causes a dangerous increase of the radiation dose to the patients and clinical staff. However, it is possible to produce another radionuclide of scandium—{sup 43}Sc—having properties similar to {sup 44}Sc but is characterized by much lower energy of the concurrent gamma emissions. This work presents the production route of {sup 43}Sc by α irradiation of natural calcium, its separation and purification processes, and the labeling of [DOTA,Tyr3] octreotate (DOTATATE) bioconjugate. Natural CaCO{sub 3} and enriched [{sup 40}Ca]CaCO{sub 3} were irradiated with alpha particles for 1 h in an energy range of 14.8–30 MeV at a beam current of 0.5 or 0.25 μA. In order to find the optimum method for the separation of {sup 43}Sc from irradiated calcium targets, three processes previously developed for {sup 44}Sc were tested. Radiolabeling experiments were performed with DOTATATE radiobioconjugate, and the stability of the obtained {sup 43}Sc-DOTATATE was tested in human serum. Studies of {sup nat}CaCO{sub 3} target irradiation by alpha particles show that the optimum alpha particle energies are in the range of 24–27 MeV, giving 102 MBq/μA/h of {sup 43}Sc radioactivity which creates the opportunity to produce several GBq of {sup 43}Sc. The separation experiments performed indicate that, as with {sup 44}Sc, due to the simplicity of the operations and because of the chemical purity of the {sup 43}Sc obtained, the best separation process is when UTEVA resin is used. The DOTATATE conjugate was labeled by the obtained {sup 43}Sc with a yield >98 % at elevated temperature. Tens of GBq activities of {sup 43}Sc of high radionuclidic purity can be obtainable for clinical applications by irradiation of natural calcium with an alpha beam.

  3. Evaluation of different disinfectants on the performance of an on-meter dosed amperometric glucose-oxidase-based glucose meter.

    Science.gov (United States)

    Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E

    2011-11-01

    Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical ( .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.

  4. Lifestyle, glucose regulation and the cognitive effects of glucose load in middle-aged adults.

    Science.gov (United States)

    Riby, Leigh M; McLaughlin, Jennifer; Riby, Deborah M; Graham, Cheryl

    2008-11-01

    Interventions aimed at improving glucose regulatory mechanisms have been suggested as a possible source of cognitive enhancement in the elderly. In particular, previous research has identified episodic memory as a target for facilitation after either moderate increases in glycaemia (after a glucose drink) or after improvements in glucose regulation. The present study aimed to extend this research by examining the joint effects of glucose ingestion and glucose regulation on cognition. In addition, risk factors associated with the development of poor glucose regulation in middle-aged adults were considered. In a repeated measures design, thirty-three middle-aged adults (aged 35-55 years) performed a battery of memory and non-memory tasks after either 25 g or 50 g glucose or a sweetness matched placebo drink. To assess the impact of individual differences in glucose regulation, blood glucose measurements were taken on four occasions during testing. A lifestyle and diet questionnaire was also administered. Consistent with previous research, episodic memory ability benefited from glucose ingestion when task demands were high. Blood glucose concentration was also found to predict performance across a number of cognitive domains. Interestingly, the risk factors associated with poor glucose regulation were linked to dietary impacts traditionally associated with poor health, e.g. the consumption of high-sugar sweets and drinks. The research replicates earlier work suggesting that task demands are critical to the glucose facilitation effect. Importantly, the data demonstrate clear associations between elevated glycaemia and relatively poor cognitive performance, which may be partly due to the effect of dietary and lifestyle factors.

  5. Cross-sections of {sup 45}Sc(n,2n){sup 44m,g}Sc reaction from the reaction threshold to 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Luo, J. [Hexi Univ., Zhangye (China). School of Physics and Electromechanical Engineering; Peking Univ., Beijing (China). State Key Laboratory of Nuclear Physics and Technology; Liu, R.; Jiang, L. [Chinese Academy of Engineering Physics, Mianyang (China). Inst. of Nuclear Physics and Chemistry; Liu, Z.; Sun, G.; Ge, S. [Hexi Univ., Zhangye (China). School of Physics and Electromechanical Engineering

    2013-07-01

    Cross sections of {sup 45}Sc(n,2n){sup 44m,g}Sc reactions and their isomeric cross section ratios {sigma}{sub m}/{sigma}{sub g} have been measured at three neutron energies between 13.5 and 14.8 MeV using the activation technique. The pure cross section of the groundstate was then obtained by utilizing the absolute cross section of the metastable state and analysis methods of residual nuclear decay. The monoenergetic neutron beam was produced via the {sup 3}H(d, n){sup 4}He reaction. The cross sections were also estimated with the TALYS-1.2 nuclear model code using different level density options, at neutron energies varying from the reaction threshold to 20 MeV. Results are also discussed and compared with some corresponding values found in the literature. (orig.)

  6. Cross-sections of 45Sc(n,2n)44m,gSc reaction from the reaction threshold to 20 MeV

    International Nuclear Information System (INIS)

    Luo, J.; Peking Univ., Beijing; Liu, R.; Jiang, L.; Liu, Z.; Sun, G.; Ge, S.

    2013-01-01

    Cross sections of 45 Sc(n,2n) 44m,g Sc reactions and their isomeric cross section ratios σ m /σ g have been measured at three neutron energies between 13.5 and 14.8 MeV using the activation technique. The pure cross section of the groundstate was then obtained by utilizing the absolute cross section of the metastable state and analysis methods of residual nuclear decay. The monoenergetic neutron beam was produced via the 3 H(d, n) 4 He reaction. The cross sections were also estimated with the TALYS-1.2 nuclear model code using different level density options, at neutron energies varying from the reaction threshold to 20 MeV. Results are also discussed and compared with some corresponding values found in the literature. (orig.)

  7. Pharmacokinetics and pharmacodynamics of various glucagon dosages at different blood glucose levels

    NARCIS (Netherlands)

    Blauw, H.; Wendl, I.; DeVries, J. H.; Heise, T.; Jax, T.

    2016-01-01

    To evaluate the pharmacokinetics and pharmacodynamics of different doses of glucagon administered subcutaneously (s.c.) at different blood glucose levels. This study was an open-label, randomized, three-period, cross-over experiment in 6 patients with type 1 diabetes. During each of the three

  8. Slow ultrafiltration for continuous in vivo sampling : application for glucose and lactate in man

    NARCIS (Netherlands)

    Tiessen, RG; Kaptein, WA; Venema, K; Korf, J

    1999-01-01

    Background: An ultrafiltration (UF) technique was developed for continuous subcutaneous (s.c.) sampling and on-line analysis of absolute glucose and lactate concentrations in tissue. The relation between subcutaneous and blood concentrations was studied in men, because a subcutaneous monitoring

  9. Ventromedial hypothalamic glucose sensing and glucose homeostasis vary throughout the estrous cycle.

    Science.gov (United States)

    Santiago, Ammy M; Clegg, Deborah J; Routh, Vanessa H

    2016-12-01

    17β-Estradiol (17βE) regulates glucose homeostasis in part by centrally mediated mechanisms. In female rodents, the influence of the ovarian cycle on hypoglycemia counterregulation and glucose tolerance is unclear. We found previously that in prepubertal females, 17βE modulates glucose sensing in nonadapting glucose-inhibited (GI) and adapting GI (AdGI) neurons within the ventrolateral portion of the ventromedial nucleus (VL-VMN). Nonadapting GI neurons persistently decrease their activity as glucose increases while AdGI neurons transiently respond to a glucose increase. To begin to understand if endogenous fluctuations in estrogen levels across the estrous cycle impact hypothalamic glucose sensing and glucose homeostasis, we assessed whether hypoglycemia counterregulation and glucose tolerance differed across the phases of the estrous cycle. We hypothesized that the response to insulin-induced hypoglycemia (IIH) and/or glucose tolerance would vary throughout the estrous cycle according to changes in 17βE availability. Moreover, that these changes would correlate with estrous-dependent changes in the glucose sensitivity of VL-VMN glucose-sensing neurons (GSNs). These hypotheses were tested in female mice by measuring the response to IIH, glucose tolerance and the glucose sensitivity of VL-VMN GSNs during each phase of the estrous cycle. Furthermore, a physiological brain concentration of 17βE seen during proestrus was acutely applied to brain slices isolated on the day of diestrous and the response to low glucose in VL-VMN GSNs was assayed. The response to IIH was strongest during diestrous. The response of nonadapting GI and AdGI neurons to a glucose decrease from 2.5 to 0.5mM also peaked during diestrous; an effect which was blunted by the addition of 17βE. In contrast, the glucose sensitivity of the subpopulation of GSNs which are excited by glucose (GE) was not affected by estrous phase or exogenous 17βE application. These data suggest that physiological

  10. Ventromedial hypothalamic glucose sensing and glucose homeostasis vary throughout the estrous cycle

    Science.gov (United States)

    Santiago, Ammy M.; Clegg, Deborah J.; Routh, Vanessa H.

    2016-01-01

    Objective 17β-Estradiol (17βE) regulates glucose homeostasis in part by centrally mediated mechanisms. In female rodents, the influence of the ovarian cycle on hypoglycemia counterregulation and glucose tolerance is unclear. We found previously that in prepubertal females, 17βE modulates glucose sensing in nonadapting glucose-inhibited (GI) and adapting GI (AdGI) neurons within the ventrolateral portion of the ventromedial nucleus (VL-VMN). Nonadapting GI neurons persistently decrease their activity as glucose increases while AdGI neurons transiently respond to a glucose increase. To begin to understand if endogenous fluctuations in estrogen levels across the estrous cycle impact hypothalamic glucose sensing and glucose homeostasis, we assessed whether hypoglycemia counterregulation and glucose tolerance differed across the phases of the estrous cycle. We hypothesized that the response to insulin-induced hypoglycemia (IIH) and/or glucose tolerance would vary throughout the estrous cycle according to changes in 17βE availability. Moreover, that these changes would correlate with estrous-dependent changes in the glucose sensitivity of VL-VMN glucose-sensing neurons (GSNs). Methods These hypotheses were tested in female mice by measuring the response to IIH, glucose tolerance and the glucose sensitivity of VL-VMN GSNs during each phase of the estrous cycle. Furthermore, a physiological brain concentration of 17βE seen during proestrus was acutely applied to brain slices isolated on the day of diestrous and the response to low glucose in VL-VMN GSNs was assayed. Results The response to IIH was strongest during diestrous. The response of nonadapting GI and AdGI neurons to a glucose decrease from 2.5 to 0.5mM also peaked during diestrous; an effect which was blunted by the addition of 17βE. In contrast, the glucose sensitivity of the subpopulation of GSNs which are excited by glucose (GE) was not affected by estrous phase or exogenous 17βE application. Conclusion

  11. Ultimate internal pressure capacity assessment of SC structure

    International Nuclear Information System (INIS)

    Park, Hyungkui; Choi, Inkil

    2013-01-01

    An SC structure applied to a containment building can be quite effective. However, an SC structure cannot be applied to a containment building, because its internal pressure resistance performance has not been verified. The containment building, which undergoes ultimate internal pressure, resists the internal pressure through a pre-stress tendon. It is hard to apply a tendon to an SC structure because of its structural characteristics. Therefore, the internal pressure resistance performance of the SC structure itself should be ensured to apply it to a structure with internal pressure resistance. In this study, the suitability of an SC structure as a substitution for the tendon of a pressure resistant structure was evaluated. A containment structure model was used in this study, because it was representative structures that resistance of ultimate internal pressure be required. In this study, a nonlinear analysis was performed to evaluate and compare the behaviors of tendon model and SC structure model. By comparing the internal pressure-displacement according to the structure type, the stability of SC structure model was assessed

  12. Synthesis, microstructural characterization and optical properties of undoped, V and Sc doped ZnO thin films

    International Nuclear Information System (INIS)

    Amezaga-Madrid, P.; Antunez-Flores, W.; Ledezma-Sillas, J.E.; Murillo-Ramirez, J.G.; Solis-Canto, O.; Vega-Becerra, O.E.; Martinez-Sanchez, R.; Miki-Yoshida, M.

    2011-01-01

    Research highlights: → Undoped, V and Sc doped ZnO thin films by Aerosol Assisted Chemical Vapour Deposition. → Optimum substrate temperatures of 673 K and 623 K for Sc and V doped films. → Around one third of the dopants in solution were deposited into the films. → Crystallite and grain size decreased with the increase of dopant concentration. → Optical band gap increased from 3.29 to 3.32 eV for undoped to 7 Sc/Zn at. %. - Abstract: Many semiconductor oxides (ZnO, TiO 2 , SnO 2 ) when doped with a low percentage of non-magnetic (V, Sc) or magnetic 3d (Co, Mn, Ni, Fe) cation behave ferromagnetically. They have attracted a great deal of interest due to the integration of semiconducting and magnetic properties in a material. ZnO is one of the most promising materials to carry out these tasks in view of the fact that it is optically transparent and has n or p type conductivity. Here, we report the synthesis, microstructural characterization and optical properties of undoped, V and Sc doped zinc oxide thin films. ZnO based thin films with additions of V and Sc were deposited by the Aerosol Assisted Chemical Vapour Deposition method. V and Sc were incorporated separately in the precursor solution. The films were uniform, transparent and non-light scattering. The microstructure of the films was characterized by Grazing Incidence X-ray Diffraction, Scanning Electron Microscopy, and Scanning Probe Microscopy. Average grain size and surface rms roughness were estimated by the measurement of Atomic Force Microscopy. The microstructure of doped ZnO thin films depended on the type and amount of dopant material incorporated. The optical properties were determined from specular reflectance and transmittance spectra. Results were analyzed to determine the optical constant and band gap of the films. An increase in the optical band gap with the content of Sc dopant was obtained.

  13. Bullying prevention in schools by targeting cognitions, emotions, and behavior: Evaluating the effectiveness of the REBE-ViSC program.

    Science.gov (United States)

    Trip, Simona; Bora, Carmen; Sipos-Gug, Sebastian; Tocai, Ioana; Gradinger, Petra; Yanagida, Takuya; Strohmeier, Dagmar

    2015-10-01

    The effectiveness of a class-based antibullying prevention program on cognitions, emotions, and behaviors was investigated. The program consists of a cognitive-behavioral (Rational Emotive Behavioral Education; REBE) and a behavioral (Viennese Social Competence; ViSC) component. The REBE program is based on rational emotive behavioral theory and contains 9 student lessons. The ViSC program is based on social learning theory and comprises 10 student lessons. The order of the programs was experimentally manipulated. The REBE-ViSC program was implemented in 5 schools (14 classes), the ViSC-REBE program was implemented in 3 schools (9 classes), and 3 schools (11 classes) served as an untreated control group. Data were collected during 1 school year at pretest, midpoint, and posttest. Emotions (overt and internalizing anger), cognitions (learning and entitlement), and behaviors (bullying perpetration and bullying victimization) were measured with self-assessments. To examine the effectiveness of the REBE-ViSC/ViSC-REBE program, multilevel growth models were applied (time points at Level 1, individuals at Level 2, and classes at Level 3). The analyses revealed that the program effects differed depending on the order of the programs. The REBE-ViSC condition was more effective in changing negative emotions than the ViSC-REBE condition; both experimental conditions were effective in reducing dysfunctional cognitions, whereas no behavioral change was found in the 2 experimental groups when compared with the control group. To improve program effectiveness regarding behavioral changes, a multilevel whole-school approach including a teacher component is recommended. (c) 2015 APA, all rights reserved).

  14. Mechanical Properties and Microstructure of TIG and FSW Joints of a New Al-Mg-Mn-Sc-Zr Alloy

    Science.gov (United States)

    Xu, Guofu; Qian, Jian; Xiao, Dan; Deng, Ying; Lu, Liying; Yin, Zhimin

    2016-04-01

    A new Al-5.8%Mg-0.4%Mn-0.25%Sc-0.10%Zr (wt.%) alloy was successfully welded by tungsten inert gas (TIG) and friction stir welding (FSW) techniques, respectively. The mechanical properties and microstructure of the welded joints were investigated by microhardness measurements, tensile tests, and microscopy methods. The results show that the ultimate tensile strength, yield strength, and elongation to failure are 358, 234 MPa, and 27.6% for TIG welded joint, and 376, 245 MPa and 31.9% for FSW joint, respectively, showing high strength and superior ductility. The TIG welded joint fails in the heat-affected zone and the fracture of FSW joint is located in stirred zone. Al-Mg-Mn-Sc-Zr alloy is characterized by lots of dislocation tangles and secondary coherent Al3(Sc,Zr) particles. The superior mechanical properties of the TIG and FSW joints are mainly derived from the Orowan strengthening and grain boundary strengthening caused by secondary coherent Al3(Sc,Zr) nano-particles (20-40 nm). For new Al-Mg-Mn-Sc-Zr alloy, the positive effect from secondary Al3(Sc, Zr) particles in the base metal can be better preserved in FSW joint than in TIG welded joint.

  15. Empty-electronic-state evolution for Sc and electron dynamics at the 3p-3d giant dipole resonance

    International Nuclear Information System (INIS)

    Hu, Y.; Wagener, T.J.; Gao, Y.; Weaver, J.H.

    1989-01-01

    Inverse photoemission has been used to study the developing electronic states of an early transition metal, Sc, during thin-film growth and to investigate the effects of these states on the 3p-3d giant dipole resonance. Energy- and coverage-dependent intensity variations of the empty Sc states show that the 3d maximum moves 1.1 eV toward the Fermi level as the thickness of the Sc film increases from 1 to 300 A as measured with an incident electron energy of 41.25 eV, an effect attributed to metallic band formation via hybridization of atomic 4s and 3d states. Incident-energy-dependent intensity variations for these empty Sc features show resonant photon emission for incident electron energies above the 3p threshold, with maxima at 43 and 44 eV for 300- and 5-A-thick films, respectively. Considerations of hybridization-induced energy shifts of the empty Sc 3d states demonstrate that the radiative energy changes very little with Sc coverages. These studies indicate coupling of decay channels involving the inverse photoemission continuum and the recombination of the atomic 3p-3d giant dipole transition, the energy of the latter being determined by atomic 3p-3d excitation processes

  16. Measurement of direct CP violation in b → sc$\\bar{c}$ and b → d$\\barc{c}$ quark transitions using B+ → J/psiK+ and B+→ J/Ψπ+ decays

    Energy Technology Data Exchange (ETDEWEB)

    Holubyev, Kostyantyn [Lancaster Univ. (United Kingdom)

    2008-11-01

    This thesis describes the measurement of the direct CP violation in the b → sc$\\bar{c}$ transition using the decay B+ → J/ΨK+, and in the b → dc$\\bar{c}$ transition using the decay B+ → J/Ψπ+. The decays of B+ mesons are reconstructed in approximately 2.8 fb-1 of data recorded by D0 detector in 2002-2007 during Run II of Fermilab Tevatron collider. Using the unbinned likelihood fit, a signal of 40,222 {+-} 242 of B+ → J/ΨK+ and 1,578 ± 119 of B+ → J/Ψπ+ events is obtained. The corresponding direct CP violation asymmetries are measured to be ACP(B+ → J/Ψ(1S)K+) = +0.0077 ± 0.0061(stat.) ± 0.0027(syst.), and ACP(B+ → J/Ψ(1S)π+) = - 0.089 ± 0.081(stat.) ± 0.028(syst.). The result on ACP (B+ → J/Ψ(1S)K+) is consistent with the 2007 world average and is the most precise measurement of this asymmetry, with uncertainty approaching the level of the Standard Model prediction. The result on ACP (B+ → J/Ψ(1S)π+) constitutes the first measurement of this asymmetry at the hadron collider, with uncertainty at the level of the 2007 world average. The measurement presented in this thesis has become possible due to the sophisticated online and offline tracking/vertexing implemented at D0, and the regular reversal of the polarities of the D0 detector magnets.

  17. Effects of hydroxyurea treatment for patients with hemoglobin SC disease.

    Science.gov (United States)

    Luchtman-Jones, Lori; Pressel, Sara; Hilliard, Lee; Brown, R Clark; Smith, Mary G; Thompson, Alexis A; Lee, Margaret T; Rothman, Jennifer; Rogers, Zora R; Owen, William; Imran, Hamayun; Thornburg, Courtney; Kwiatkowski, Janet L; Aygun, Banu; Nelson, Stephen; Roberts, Carla; Gauger, Cynthia; Piccone, Connie; Kalfa, Theodosia; Alvarez, Ofelia; Hassell, Kathryn; Davis, Barry R; Ware, Russell E

    2016-02-01

    Although hemoglobin SC (HbSC) disease is usually considered less severe than sickle cell anemia (SCA), which includes HbSS and HbS/β(0) -thalassemia genotypes, many patients with HbSC experience severe disease complications, including vaso-occlusive pain, acute chest syndrome, avascular necrosis, retinopathy, and poor quality of life. Fully 20 years after the clinical and laboratory efficacy of hydroxyurea was proven in adult SCA patients, the safety and utility of hydroxyurea treatment for HbSC patients remain unclear. Recent NHLBI evidence-based guidelines highlight this as a critical knowledge gap, noting HbSC accounts for ∼30% of sickle cell patients within the United States. To date, only 5 publications have reported short-term, incomplete, or conflicting laboratory and clinical outcomes of hydroxyurea treatment in a total of 71 adults and children with HbSC. We now report on a cohort of 133 adult and pediatric HbSC patients who received hydroxyurea, typically for recurrent vaso-occlusive pain. Hydroxyurea treatment was associated with a stable hemoglobin concentration; increased fetal hemoglobin (HbF) and mean corpuscular volume (MCV); and reduced white blood cell count (WBC), absolute neutrophil count (ANC), and absolute reticulocyte count (ARC). Reversible cytopenias occurred in 22% of patients, primarily neutropenia and thrombocytopenia. Painful events were reduced with hydroxyurea, more in patients >15 years old. These multicenter data support the safety and potentially salutary effects of hydroxyurea treatment for HbSC disease; however, a multicenter, placebo-controlled, Phase 3 clinical trial is needed to determine if hydroxyurea therapy has efficacy for patients with HbSC disease. © 2015 Wiley Periodicals, Inc.

  18. Laboratory oscillator strengths of Sc i in the near-infrared region for astrophysical applications

    Science.gov (United States)

    Pehlivan, A.; Nilsson, H.; Hartman, H.

    2015-10-01

    Context. Atomic data is crucial for astrophysical investigations. To understand the formation and evolution of stars, we need to analyse their observed spectra. Analysing a spectrum of a star requires information about the properties of atomic lines, such as wavelengths and oscillator strengths. However, atomic data of some elements are scarce, particularly in the infrared region, and this paper is part of an effort to improve the situation on near-IR atomic data. Aims: This paper investigates the spectrum of neutral scandium, Sc I, from laboratory measurements and improves the atomic data of Sc I lines in the infrared region covering lines in R, I, J, and K bands. Especially, we focus on measuring oscillator strengths for Sc I lines connecting the levels with 4p and 4s configurations. Methods: We combined experimental branching fractions with radiative lifetimes from the literature to derive oscillator strengths (f-values). Intensity-calibrated spectra with high spectral resolution were recorded with Fourier transform spectrometer from a hollow cathode discharge lamp. The spectra were used to derive accurate oscillator strengths and wavelengths for Sc I lines, with emphasis on the infrared region. Results: This project provides the first set of experimental Sc I lines in the near-infrared region for accurate spectral analysis of astronomical objects. We derived 63 log(gf) values for the lines between 5300 Å and 24 300 Å. The uncertainties in the f-values vary from 5% to 20%. The small uncertainties in our values allow for an increased accuracy in astrophysical abundance determinations.

  19. Natural moisturizing factors (NMF) in the stratum corneum (SC). I. Effects of lipid extraction and soaking.

    Science.gov (United States)

    Robinson, Marisa; Visscher, Marty; Laruffa, Angela; Wickett, Randy

    2010-01-01

    Natural moisturizing factor (NMF) is essential for appropriate stratum corneum hydration, barrier homeostasis, desquamation, and plasticity. It is formed from filaggrin proteolysis to small, hygroscopic molecules including amino acids. We hypothesized that common lipid extraction and soaking in water would alter the level of NMF in the upper SC and its biophysical properties. A novel method of measuring and quantifying the amino acid components of NMF is presented. Adhesive tapes were used to collect samples of the stratum corneum (SC) and were extracted with 6mM perchloric acid for analysis by reverse-phase HPLC. HPLC results were standardized to the amount of protein removed by the tapes. An increase in NMF was found with increased SC depth. Also, the combination of extraction and soaking was found to increase NMF loss relative to control or to extraction or soaking alone. Our results indicate that common skin care practices significantly influence the water binding materials in the upper SC. The findings have implications for the evaluation and formulation of skin care products.

  20. In Vitro Evaluation of Fluorescence Glucose Biosensor Response

    OpenAIRE

    Aloraefy, Mamdouh; Pfefer, T. Joshua; Ramella-Roman, Jessica C.; Sapsford, Kim E.

    2014-01-01

    Rapid, accurate, and minimally-invasive glucose biosensors based on Förster Resonance Energy Transfer (FRET) for glucose measurement have the potential to enhance diabetes control. However, a standard set of in vitro approaches for evaluating optical glucose biosensor response under controlled conditions would facilitate technological innovation and clinical translation. Towards this end, we have identified key characteristics and response test methods, fabricated FRET-based glucose biosensor...

  1. Gadolinium scandium germanide, Gd2Sc3Ge4

    Directory of Open Access Journals (Sweden)

    Sumohan Misra

    2009-04-01

    Full Text Available Gd2Sc3Ge4 adopts the orthorhombic Pu5Rh4-type structure. The crystal structure contains six sites in the asymmetric unit: two sites are statistically occupied by rare-earth atoms with Gd:Sc ratios of 0.967 (4:0.033 (4 and 0.031 (3:0.969 (3, one site (.m. symmetry is occupied by Sc atoms, and three distinct sites (two of which with .m. symmetry are occupied by Ge atoms. The rare-earth atoms form two-dimensional slabs with Ge atoms occupying the trigonal-prismatic voids.

  2. Pascal-SC a computer language for scientific computation

    CERN Document Server

    Bohlender, Gerd; von Gudenberg, Jürgen Wolff; Rheinboldt, Werner; Siewiorek, Daniel

    1987-01-01

    Perspectives in Computing, Vol. 17: Pascal-SC: A Computer Language for Scientific Computation focuses on the application of Pascal-SC, a programming language developed as an extension of standard Pascal, in scientific computation. The publication first elaborates on the introduction to Pascal-SC, a review of standard Pascal, and real floating-point arithmetic. Discussions focus on optimal scalar product, standard functions, real expressions, program structure, simple extensions, real floating-point arithmetic, vector and matrix arithmetic, and dynamic arrays. The text then examines functions a

  3. Abnormal temporal lobe response in Alzheimer's disease during cognitive processing as measured by 11C-2-deoxy-D-glucose and PET

    International Nuclear Information System (INIS)

    Miller, J.D.; de Leon, M.J.; Ferris, S.H.; Kluger, A.; George, A.E.; Reisberg, B.; Sachs, H.J.; Wolf, A.P.

    1987-01-01

    Elderly controls and probable Alzheimer's disease patients underwent serial positron emission tomography (PET) studies during a baseline condition and while performing a verbal memory task. For the temporal lobes, all 7 Alzheimer patients demonstrated a relative shift in glucose metabolic rates to the right hemisphere during the memory condition relative to baseline, and 5 of 7 controls showed a shift to the left hemisphere. Baseline absolute regional metabolic rates replicate previous findings and were somewhat less useful than the memory challenge in differentiating patients from controls. These results indicate that a temporal lobe abnormality in Alzheimer's disease is related to memory performance

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ...

  5. Biostable glucose permeable polymer

    DEFF Research Database (Denmark)

    2017-01-01

    A new biostable glucose permeable polymer has been developed which is useful, for example, in implantable glucose sensors. This biostable glucose permeable polymer has a number of advantageous characteristics and, for example, does not undergo hydrolytic cleavage and degradation, thereby providing...... a composition that facilitates long term sensor stability in vivo. The versatile characteristics of this polymer allow it to be used in a variety of contexts, for example to form the body of an implantable glucose sensor. The invention includes the polymer composition, sensor systems formed from this polymer...

  6. Glucokinase, the pancreatic glucose sensor, is not the gut glucose sensor

    DEFF Research Database (Denmark)

    Murphy, R; Tura, A; Clark, P M

    2008-01-01

    AIMS/HYPOTHESIS: The incretin hormones glucagon-like peptide-1 (GLP-1) and glucose-dependent insulinotrophic peptide (GIP) are released from intestinal endocrine cells in response to luminal glucose. Glucokinase is present in these cells and has been proposed as a glucose sensor. The physiological...... role of glucokinase can be tested using individuals with heterozygous glucokinase gene (GCK) mutations. If glucokinase is the gut glucose sensor, GLP-1 and GIP secretion during a 75 g OGTT would be lower in GCK mutation carriers compared with controls. METHODS: We compared GLP-1 and GIP concentrations...... measured at five time-points during a 75 g OGTT in 49 participants having GCK mutations with those of 28 familial controls. Mathematical modelling of glucose, insulin and C-peptide was used to estimate basal insulin secretion rate (BSR), total insulin secretion (TIS), beta cell glucose sensitivity...

  7. Effects of Endogenous Androgens and Abdominal Fat Distribution on the Interrelationship Between Insulin and Non-Insulin-Mediated Glucose Uptake in Females

    Science.gov (United States)

    Ezeh, Uche; Pall, Marita; Mathur, Ruchi; Dey, Damini; Berman, Daniel; Chen, Ida Y.; Dumesic, Daniel A.

    2013-01-01

    Background: Polycystic ovary syndrome (PCOS) is associated with hyperandrogenism and insulin resistance. Glucose disposal occurs via noninsulin-mediated glucose uptake (NIMGU) and insulin-mediated glucose uptake (IMGU). It is unknown whether in PCOS NIMGU increases to compensate for declining IMGU and whether androgens and fat distribution influence this relationship. Objectives: The objective of the study was to compare in women with PCOS and controls the interrelationship between NIMGU [ie, glucose effectiveness (Sg)] and IMGU [ie, the insulin sensitivity index (Si)] and the role of androgens and fat distribution. Participants: Twenty-eight PCOS (by National Institutes of Health 1990 criteria) and 28 control (age, race, and body mass index matched) women were prospectively studied. A subset of 16 PCOS subjects and 16 matched controls also underwent abdominal computed tomography. Main Outcome Measures: Glucose disposal (by a frequently sampled iv glucose tolerance test), circulating androgens, and abdominal fat distribution [by waist to hip ratio and visceral (VAT) and sc (SAT) adipose tissue content] were measured. Results: PCOS women had lower mean Si and similar Sg and abdominal fat distribution compared with controls. PCOS women with Si below the PCOS median (more insulin resistant) had a lower mean Sg than controls with Si above the control median (more insulin sensitive). In PCOS only, body mass index, free T, modified Ferriman-Gallwey score, and waist to hip ratio independently predicted Sg, whereas Si did not. In PCOS, VAT and SAT independently and negatively predicted Si and Sg, respectively. Conclusion: The decreased IMGU in PCOS is not accompanied by a compensatory increase in NIMGU or associated with excessive VAT accumulation. Increased general obesity, SAT, and hyperandrogenism are primary predictors of the deterioration of NIMGU in PCOS. PMID:23450052

  8. Infectivity-associated PrP(Sc) and disease duration-associated PrP(Sc) of mouse BSE prions.

    Science.gov (United States)

    Miyazawa, Kohtaro; Okada, Hiroyuki; Masujin, Kentaro; Iwamaru, Yoshifumi; Yokoyama, Takashi

    2015-01-01

    Disease-related prion protein (PrP(Sc)), which is a structural isoform of the host-encoded cellular prion protein, is thought to be a causative agent of transmissible spongiform encephalopathies. However, the specific role of PrP(Sc) in prion pathogenesis and its relationship to infectivity remain controversial. A time-course study of prion-affected mice was conducted, which showed that the prion infectivity was not simply proportional to the amount of PrP(Sc) in the brain. Centrifugation (20,000 ×g) of the brain homogenate showed that most of the PrP(Sc) was precipitated into the pellet, and the supernatant contained only a slight amount of PrP(Sc). Interestingly, mice inoculated with the obtained supernatant showed incubation periods that were approximately 15 d longer than those of mice inoculated with the crude homogenate even though both inocula contained almost the same infectivity. Our results suggest that a small population of fine PrP(Sc) may be responsible for prion infectivity and that large, aggregated PrP(Sc) may contribute to determining prion disease duration.

  9. Solid-State NMR Spectroscopy Proves the Presence of Penta-coordinated Sc Sites in MIL-100(Sc).

    Science.gov (United States)

    Giovine, Raynald; Volkringer, Christophe; Ashbrook, Sharon E; Trébosc, Julien; McKay, David; Loiseau, Thierry; Amoureux, Jean-Paul; Lafon, Olivier; Pourpoint, Frédérique

    2017-07-18

    Advanced solid-state NMR methods and first-principles calculations demonstrate for the first time the formation of penta-coordinated scandium sites. These coordinatively unsaturated sites were shown during the thermal activation of scandium-based metal-organic frameworks (MOFs). A 45 Sc NMR experiment allows their specific observation in activated Sc 3 BTB 2 (H 3 BTB=1,3,5-tris(4-carboxyphenyl)benzene) and MIL-100(Sc) MOFs. The assignment of the ScO 5 groups is supported by the DFT calculations of NMR parameters. The presence of ScO 5 Lewis acid sites in MIL-100(Sc) explains furthermore its catalytic activity. The first NMR experiment to probe 13 C- 45 Sc distances is also introduced. This advanced solid-state NMR pulse sequence allows the demonstration of the shrinkage of the MIL-100(Sc) network when the activation temperature is raised. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. The glucose oxidase-peroxidase assay for glucose

    Science.gov (United States)

    The glucose oxidase-peroxidase assay for glucose has served as a very specific, sensitive, and repeatable assay for detection of glucose in biological samples. It has been used successfully for analysis of glucose in samples from blood and urine, to analysis of glucose released from starch or glycog...

  11. Korean Red Ginseng Improves Glucose Control in Subjects with Impaired Fasting Glucose, Impaired Glucose Tolerance, or Newly Diagnosed Type 2 Diabetes Mellitus

    OpenAIRE

    Bang, Hyangju; Kwak, Jung Hyun; Ahn, Hyeon Yeong; Shin, Dong Yeob; Lee, Jong Ho

    2014-01-01

    This study was designed to evaluate the effect of Korean red ginseng (KRG) supplementation on glucose control in subjects with impaired fasting glucose (IFG), impaired glucose tolerance (IGT), or newly diagnosed type 2 diabetes mellitus (T2DM). The study was a 12-week randomized, double-blinded, placebo-controlled (5 g of KRG [n=21] or placebo [n=20] in tablet form) trial. Glucose-related biomarkers, including serum and whole blood levels of glucose, insulin, and C-peptide, were measured by 2...

  12. Association between blood glucose level derived using the oral glucose tolerance test and glycated hemoglobin level.

    Science.gov (United States)

    Kim, Hyoung Joo; Kim, Young Geon; Park, Jin Soo; Ahn, Young Hwan; Ha, Kyoung Hwa; Kim, Dae Jung

    2016-05-01

    Glycated hemoglobin (HbA1c) is widely used as a marker of glycemic control. Translation of the HbA1c level to an average blood glucose level is useful because the latter figure is easily understood by patients. We studied the association between blood glucose levels revealed by the oral glucose tolerance test (OGTT) and HbA1c levels in a Korean population. A total of 1,000 subjects aged 30 to 64 years from the Cardiovascular and Metabolic Diseases Etiology Research Center cohort were included. Fasting glucose levels, post-load glucose levels at 30, 60, and 120 minutes into the OGTT, and HbA1c levels were measured. Linear regression of HbA1c with mean blood glucose levels derived using the OGTT revealed a significant correlation between these measures (predicted mean glucose [mg/dL] = 49.4 × HbA1c [%] - 149.6; R (2) = 0.54, p Glucose (ADAG) study and Diabetes Control and Complications Trial (DCCT) cohort. Discrepancies between our results and those of the ADAG study and DCCT cohort may be attributable to differences in the test methods used and the extent of insulin secretion. More studies are needed to evaluate the association between HbA1c and self monitoring blood glucose levels.

  13. Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: Implications for clinical practice.

    Science.gov (United States)

    Ajjan, Ramzi A; Cummings, Michael H; Jennings, Peter; Leelarathna, Lalantha; Rayman, Gerry; Wilmot, Emma G

    2018-02-01

    Continuous glucose monitoring and flash glucose monitoring technologies measure glucose in the interstitial fluid and are increasingly used in diabetes care. Their accuracy, key to effective glycaemic management, is usually measured using the mean absolute relative difference of the interstitial fluid sensor compared to reference blood glucose readings. However, mean absolute relative difference is not standardised and has limitations. This review aims to provide a consensus opinion on assessing accuracy of interstitial fluid glucose sensing technologies. Mean absolute relative difference is influenced by glucose distribution and rate of change; hence, we express caution on the reliability of comparing mean absolute relative difference data from different study systems and conditions. We also review the pitfalls associated with mean absolute relative difference at different glucose levels and explore additional ways of assessing accuracy of interstitial fluid devices. Importantly, much data indicate that current practice of assessing accuracy of different systems based on individualised mean absolute relative difference results has limitations, which have potential clinical implications. Healthcare professionals must understand the factors that influence mean absolute relative difference as a metric for accuracy and look at additional assessments, such as consensus error grid analysis, when evaluating continuous glucose monitoring and flash glucose monitoring systems in diabetes care. This in turn will ensure that management decisions based on interstitial fluid sensor data are both effective and safe.

  14. Glucose absorption in acute peritoneal dialysis.

    Science.gov (United States)

    Podel, J; Hodelin-Wetzel, R; Saha, D C; Burns, G

    2000-04-01

    During acute peritoneal dialysis (APD), it is known that glucose found in the dialysate solution contributes to the provision of significant calories. It has been well documented in continuous ambulatory peritoneal dialysis (CAPD) that glucose absorption occurs. In APD, however, it remains unclear how much glucose absorption actually does occur. Therefore, the purpose of this study was to determine whether it is appropriate to use the formula used to calculate glucose absorption in CAPD (Grodstein et al) among patients undergoing APD. Actual measurements of glucose absorption (Method I) were calculated in 9 patients undergoing APD treatment for >24 hours who were admitted to the intensive care unit. Glucose absorption using the Grodstein et al formula (Method II) was also determined and compared with the results of actual measurements. The data was then further analyzed based on the factors that influence glucose absorption, specifically dwell time and concentration. The mean total amount of glucose absorbed was 43% +/- 15%. However, when dwell time and concentration were further examined, significant differences were noted. Method I showed a cumulative increase over time. Method II showed that absorption was fixed. This suggests that with the variation in dwell time commonly seen in the acute care setting, the use of Method II may not be accurate. In each of the 2 methods, a significant difference in glucose absorption was noted when comparing the use of 1.5% and 4.25% dialysate concentrations. The established formula designed for CAPD should not be used for calculating glucose absorption in patients receiving APD because variation in dwell time and concentration should be taken into account. Because of the time constraints and staffing required to calculate each exchange individually, combined with the results of the study, we recommend the use of the percentage estimate of 40% to 50%.

  15. Toward CMOS image sensor based glucose monitoring.

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Kim, Sanghyo

    2012-09-07

    Complementary metal oxide semiconductor (CMOS) image sensor is a powerful tool for biosensing applications. In this present study, CMOS image sensor has been exploited for detecting glucose levels by simple photon count variation with high sensitivity. Various concentrations of glucose (100 mg dL(-1) to 1000 mg dL(-1)) were added onto a simple poly-dimethylsiloxane (PDMS) chip and the oxidation of glucose was catalyzed with the aid of an enzymatic reaction. Oxidized glucose produces a brown color with the help of chromogen during enzymatic reaction and the color density varies with the glucose concentration. Photons pass through the PDMS chip with varying color density and hit the sensor surface. Photon count was recognized by CMOS image sensor depending on the color density with respect to the glucose concentration and it was converted into digital form. By correlating the obtained digital results with glucose concentration it is possible to measure a wide range of blood glucose levels with great linearity based on CMOS image sensor and therefore this technique will promote a convenient point-of-care diagnosis.

  16. Final Technical Report for DE-SC0012297

    Energy Technology Data Exchange (ETDEWEB)

    Dell' Antonio, Ian [Brown Univ., Providence, RI (United States)

    2017-08-01

    This is the final report on the work performed in award DE-SC0012297, Cosmic Frontier work in support of the LSST Dark Energy Science Collaboration's work to develop algorithms, simulations, and statistical tests to ensure optimal extraction of the dark energy properties from galaxy clusters observed with LSST. This work focused on effects that could produce a systematic error on the measurement of cluster masses (that will be used to probe the effects of dark energy on the growth of structure). These effects stem from the deviations from pure ellipticity of the gravitational lensing signal and from the blending of light of neighboring galaxies. Both these effects are expected to be more significant for LSST than for the stage III experiments such as the Dark Energy Survey. We calculate the magnitude of the mass error (or bias) for the first time and demonstrate that it can be treated as a multiplicative correction and calibrated out, allowing mass measurements of clusters from gravitational lensing to meet the requirements of LSST's dark energy investigation.

  17. Glucose homeostasis in children with falciparum malaria: precursor supply limits gluconeogenesis and glucose production

    NARCIS (Netherlands)

    Dekker, E.; Hellerstein, M. K.; Romijn, J. A.; Neese, R. A.; Peshu, N.; Endert, E.; Marsh, K.; Sauerwein, H. P.

    1997-01-01

    To evaluate glucose kinetics in children with falciparum malaria, basal glucose production and gluconeogenesis and an estimate of the flux of the gluconeogenic precursors were measured in Kenyan children with uncomplicated falciparum malaria before (n = 11) and during infusion of alanine (1.5

  18. Oral glucose intake inhibits hypothalamic neuronal activity more effectively than glucose infusion

    NARCIS (Netherlands)

    Smeets, P.A.M.; Vidarsdottir, S.; Graaf, de C.; Stafleu, A.; Osch, M.J.P.; Viergever, M.A.; Pijl, H.; Grond, van der J.

    2007-01-01

    Oral glucose intake inhibits hypothalamic neuronal activity more effectively than glucose infusion. Am J Physiol Endocrinol Metab 293: E754-E758, 2007. First published June 12, 2007; doi:10.1152/ajpendo.00231.2007. - We previously showed that hypothalamic neuronal activity, as measured by the blood

  19. Oral glucose intake inhibits hypothalamic neuronal activity more effectively than glucose infusion

    NARCIS (Netherlands)

    Smeets, P.A.M.; Vidarsdottir, S.; Graaf, C. de; Stafleu, A.; Osch, M.J.P. van; Viergever, M.A.; Pijl, H.; Grond, J. van der

    2007-01-01

    We previously showed that hypothalamic neuronal activity, as measured by the blood oxygen level-dependent (BOLD) functional MRI signal, declines in response to oral glucose intake. To further explore the mechanism driving changes in hypothalamic neuronal activity in response to an oral glucose load,

  20. Aluminum gallium nitride (GaN)/GaN high electron mobility transistor-based sensors for glucose detection in exhaled breath condensate.

    Science.gov (United States)

    Chu, Byung Hwan; Kang, Byoung Sam; Hung, Sheng Chun; Chen, Ke Hung; Ren, Fan; Sciullo, Andrew; Gila, Brent P; Pearton, Stephen J

    2010-01-01

    Immobilized aluminum gallium nitride (AlGaN)/GaN high electron mobility transistors (HEMTs) have shown great potential in the areas of pH, chloride ion, and glucose detection in exhaled breath condensate (EBC). HEMT sensors can be integrated into a wireless data transmission system that allows for remote monitoring. This technology offers the possibility of using AlGaN/GaN HEMTs for extended investigations of airway pathology of detecting glucose in EBC without the need for clinical visits. HEMT structures, consisting of a 3-microm-thick undoped GaN buffer, 30-A-thick Al(0.3)Ga(0.7)N spacer, and 220-A-thick silicon-doped Al(0.3)Ga(0.7)N cap layer, were used for fabricating the HEMT sensors. The gate area of the pH, chloride ion, and glucose detection was immobilized with scandium oxide (Sc(2)O(3)), silver chloride (AgCl) thin film, and zinc oxide (ZnO) nanorods, respectively. The Sc(2)O(3)-gated sensor could detect the pH of solutions ranging from 3 to 10 with a resolution of approximately 0.1 pH. A chloride ion detection limit of 10(-8) M was achieved with a HEMT sensor immobilized with the AgCl thin film. The drain-source current of the ZnO nanorod-gated AlGaN/GaN HEMT sensor immobilized with glucose oxidase showed a rapid response of less than 5 seconds when the sensor was exposed to the target glucose in a buffer with a pH value of 7.4. The sensor could detect a wide range of concentrations from 0.5 nM to 125 microM. There is great promise for using HEMT-based sensors to enhance the detection sensitivity for glucose detection in EBC. Depending on the immobilized material, HEMT-based sensors can be used for sensing different materials. These electronic detection approaches with rapid response and good repeatability show potential for the investigation of airway pathology. The devices can also be integrated into a wireless data transmission system for remote monitoring applications. This sensor technology could use the exhaled breath condensate to measure the

  1. Design of SC walls and slabs for impulsive loading

    Energy Technology Data Exchange (ETDEWEB)

    Varma, Amit H. [Purdue Univ., West Lafayette, IN (United States)

    2015-11-11

    Reinforced concrete (RC) structures have historically been the preferred choice for blast resistant structures because of their mass and the ductility provided by steel reinforcement. Steel-plate composite (SC) walls are a viable alternative to RC for protecting the infrastructure against explosive threats. SC structures consist of two steel faceplates with a plain concrete core between them. The steel faceplates are anchored to the concrete using stud anchors and connected to each other using tie bars. SC structures provide mass from the concrete infill and ductility from the continuous external steel faceplates. This dissertation presents findings and recommendations from experimental and analytical investigations of the performance of SC walls subjected to far-field blast loads.

  2. The data acquisition system (DAS) for the improved CERN SC

    CERN Document Server

    Beger, H; Fiebig, A; Schroot, H

    1975-01-01

    A digital data acquisition system (DAS) based on a minicomputer is described which registers the failure sequences in various equipment areas of the CERN synchrocyclotron (henceforward referred to as the SC). The avalanches of failure signals which occur from time to time are tapped from the alarm/security systems, time-resolved to 10 msec and recorded on a printer in order to aid SC failure diagnosis. The mechanisms of the DAS and its relation to the SC equipment are explained in some detail. All programs were constructed at assembler language level for speed and for ease of on-line program maintenance. The alarm sequences recorded have been of considerable help during the running in of the new radiofrequency system. Now that the new SC is operational, the DAS furnishes useful data from several equipment areas to the operators and engineers.

  3. Cytogenetic diagnosis of Roberts SC phocomelia syndrome: First ...

    African Journals Online (AJOL)

    Tahir M. Malla

    2015-07-14

    /licenses/by-nc-nd/4.0/). 1. Introduction. Roberts SC phocomelia syndrome is an autosomal recessive developmental disorder characterized by pre and postnatal growth retardation, microcephaly, craniofacial anomalies,.

  4. Development of SC structure modularization in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Mun, Taeyoup

    2008-01-01

    New Focus on NPP are Rising Concerns on Global Warming, Potential energy crisis (geo-political), Improved reliability and safety of nuclear power plant, Advent of Generation 3+ NPP technology and Economical Energy Resource. New NPPs are 6 units in Korea and 23 in Asia being built, 32 units being planned in China by 2020 (150 by 2050), 10 units being planned in US by 2020 and IAEA expects $200 billions on NPP construction next 25 years (up to 30% of total world energy). □ SC(Steel Plate Concrete) structure · Steel Plate is used as a Structural Element instead of Reinforcing Bars in RC · SC structure consists of Steel Plate with Headed Studs. Connected by Tie-bars - The Primary Purpose of Tie-bars is to Stiffen and Hold Together the Plates during Construction Process - Headed Studs are Welded to the Inside of Steel Plate for composite action □ Benefits of SC Structure · Shorten Construction Duration for Re bar, Forming and Scaffolding Works · Minimize Site Labors · Improve the Construction Quality · Enable Construction Sites to be kept Clean □ SC Modularization · Fit for Modular Construction for Structural Features · Fit for Modular Construction for Structural Features · Inattentively Effective for Integrated Modules · Pre-fabrication, Pre-assembly and Modularization □ Project Overview · Project Name: Development of SC structure for Modularization in NPP · Project Type: Electric Power Industry R and D (Ministry of Knowledge Economy) · Duration: Sep. 2005 ∼ Aug. 2008 (36 Months) · Research Team and Scopes - Project Management: Korea Hydro and Nuclear Power Company (KHNP) - Development of Code and Standards for SC Structure: Korea Society of Steel Construction (KSSC) Korea Electric Power Research Institute (KEPRI) - Development of SC Structural Analysis and Design: Korea Power Engineering Company (KOPEC) - Development of Construction Techniques for SC Modularization: KHNP, Korea Institute of Nuclear Safety(KINS), KOPEC □ Performance

  5. Response variability to glucose facilitation of cognitive enhancement.

    Science.gov (United States)

    Owen, Lauren; Scholey, Andrew; Finnegan, Yvonne; Sünram-Lea, Sandra I

    2013-11-01

    Glucose facilitation of cognitive function has been widely reported in previous studies (including our own). However, several studies have also failed to detect glucose facilitation. There is sparsity of research examining the factors that modify the effect of glucose on cognition. The aims of the present study were to (1) demonstrate the previously observed enhancement of cognition through glucose administration and (2) investigate some of the factors that may exert moderating roles on the behavioural response to glucose, including glucose regulation, body composition (BC) and hypothalamic–pituitary–adrenal axis response. A total of twenty-four participants took part in a double-blind, placebo-controlled, randomised, repeated-measures study, which examined the effect of 25 and 60 g glucose compared with placebo on cognitive function. At 1 week before the study commencement, all participants underwent an oral glucose tolerance test. Glucose facilitated performance on tasks of numeric and spatial working memory, verbal declarative memory and speed of recognition. Moderating variables were examined using several indices of glucoregulation and BC. Poorer glucoregulation predicted improved immediate word recall accuracy following the administration of 25 g glucose compared with placebo. Those with better glucoregulation showed performance decrements on word recall accuracy following the administration of 25 g glucose compared with placebo. These findings are in line with accumulating evidence that glucose load may preferentially enhance cognition in those with poorer glucoregulation. Furthermore, the finding that individuals with better glucoregulation may suffer impaired performance following a glucose load is novel and requires further substantiation.

  6. Noninvasive glucose monitoring using saliva nano-biosensor

    Directory of Open Access Journals (Sweden)

    Wenjun Zhang

    2015-06-01

    Full Text Available Millions of people worldwide live with diabetes and several millions die from it each year. A noninvasive, painless method of glucose testing would highly improve compliance and glucose control while reducing complications and overall disease management costs. To provide accurate, low cost, and continuous glucose monitoring, we have developed a unique, disposable saliva nano-biosensor. More than eight clinical trials on real-time noninvasive salivary glucose monitoring were carried out on two healthy individuals (a 2–3 h-period for each trial, including both regular food and standard glucose beverage intake with more than 35 saliva samples obtained. Excellent clinical accuracy was revealed as compared to the UV Spectrophotometer. By measuring subjects’ salivary glucose and blood glucose in parallel, we found the two generated profiles share the same fluctuation trend but the correlation between them is individual dependent. There is a time lag between the peak glucose values from blood and from saliva. However, the correlation between the two glucose values at fasting is constant for each person enabling noninvasive diagnosis of diabetes through saliva instead of blood. Furthermore, a good correlation of glucose levels in saliva and in blood before and 2 h after glucose intake was observed. Glucose monitoring before and 2 h after meals is usually prescribed by doctors for diabetic patients. Thus, this disposable biosensor will be an alternative for real-time salivary glucose tracking at any time.

  7. Electrochemical Characterization of Ni/(Sc)YSZ Electrodes

    DEFF Research Database (Denmark)

    Ramos, Tania; Thydén, Karl Tor Sune; Mogensen, Mogens Bjerg

    2010-01-01

    Investigations of Ni/(Sc)YSZ cermets for solid oxide cells (SOCs) were performed by electrochemical impedance spectroscopy (EIS), under varying experimental conditions and upon redox cycling, using three different designs of symmetric cells. The deconvolution and fitting of the obtained impedance...... parameters. Initial degradation results for both Ni/ScYSZ and Ni/YSZ based anodes under very high steam content are also reported. ©2010 COPYRIGHT ECS - The Electrochemical Society...

  8. Mathematical models of some geomagnetic storms with SC

    International Nuclear Information System (INIS)

    Ivanova, P.K.

    1990-01-01

    Regressive equations for H horizontal component of three geomagnetic storms with Sc:0.1.03.82, 24.01.74 and 23.03.69 -are calculated using step-by-step regression analysis. These equations relate H with parameters of solar wind and interplanetary magnetic field. Nonlinear, square, logarithmic and trigonometric dependences are considered, as well. Most essential parameters, which contribute mostly into Sc, are determined from multiplicity (46 factors) of independent parameters

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page ... and-how-tos, . In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for ... is checking your blood glucose often. Ask your doctor how often you should ... associated with hyperglycemia. How Do I Treat Hyperglycemia? ...

  11. Brain Glucose Metabolism Controls Hepatic Glucose and Lipid Production

    OpenAIRE

    Lam, Tony K.T.

    2007-01-01

    Brain glucose-sensing mechanisms are implicated in the regulation of feeding behavior and hypoglycemic-induced hormonal counter-regulation. This commentary discusses recent findings indicating that the brain senses glucose to regulate both hepatic glucose and lipid production.

  12. Nanomaterials in glucose sensing

    CERN Document Server

    Burugapalli, Krishna

    2013-01-01

    The smartness of nano-materials is attributed to their nanoscale and subsequently unique physicochemical properties and their use in glucose sensing has been aimed at improving performance, reducing cost and miniaturizing the sensor and its associated instrumentation. So far, portable (handheld) glucose analysers were introduced for hospital wards, emergency rooms and physicians' offices; single-use strip systems achieved nanolitre sampling for painless and accurate home glucose monitoring; advanced continuous monitoring devices having 2 to 7 days operating life are in clinical and home use; and continued research efforts are being made to develop and introduce increasingly advanced glucose monitoring systems for health as well as food, biotechnology, cell and tissue culture industries. Nanomaterials have touched every aspect of biosensor design and this chapter reviews their role in the development of advanced technologies for glucose sensing, and especially for diabetes. Research shows that overall, nanomat...

  13. α-ScVSe2O8, β-ScVSe2O8, and ScVTe2O8: new quaternary mixed metal oxides composed of only second-order Jahn-Teller distortive cations.

    Science.gov (United States)

    Kim, Yeong Hun; Lee, Dong Woo; Ok, Kang Min

    2013-10-07

    Three new quaternary scandium vanadium selenium/tellurium oxides, α-ScVSe2O8, β-ScVSe2O8, and ScVTe2O8 have been synthesized through hydrothermal and standard solid-state reactions. Although all three reported materials are stoichiometrically similar, they exhibit different crystal structures: α-ScVSe2O8 has a three-dimensional framework structure consisting of ScO6, VO6, and SeO3 groups. β-ScVSe2O8 reveals another three-dimensional framework composed of ScO7, VO5, and SeO3 polyhedra. ScVTe2O8 shows a layered structure with ScO6, VO4, and TeO4 polyhedra. Interestingly, the constituent cations, that is, Sc(3+), V(5+), Se(4+), and Te(4+) are all in a distorted coordination environment attributable to second-order Jahn-Teller (SOJT) effects. Complete characterizations including infrared spectroscopy, elemental analyses, thermal analyses, dipole moment calculation, and the magnitudes of out-of-center distortions for the compounds are reported. Transformation reactions suggest that α-ScVSe2O8 may change to β-ScVSe2O8, and then to Sc2(SeO3)3·H2O under hydrothermal conditions.

  14. Kidney transplantation improves arterial function measured by pulse wave analysis and endothelium-independent dilatation in uraemic patients despite deterioration of glucose metabolism

    DEFF Research Database (Denmark)

    Hornum, Mads; Clausen, Peter; Idorn, Thomas

    2011-01-01

    for kidney transplantation (uraemic control group, age 47 ± 11 years). Arterial function was estimated by the pulse wave velocity (PWV) of the carotid-femoral pulse wave, aortic augmentation index (AIX), flow-mediated (FMD) and nitroglycerin-induced vasodilatation (NID) of the brachial artery performed......BACKGROUND: The aim of this study is to investigate the effect of kidney transplantation on arterial function in relation to changes in glucose metabolism. METHODS: Included were 40 kidney recipients (Tx group, age 38 ± 13 years) and 40 patients without known diabetes remaining on the waiting list...... before transplantation and after 12 months. PWV recorded sequentially at the carotid and femoral artery is an estimate of arterial stiffness; AIX is an integrated index of vascular and ventricular function. FMD and NID are the dilatory capacities of the brachial artery after increased flow (endothelium...

  15. Challenges and perspectives in continuous glucose monitoring.

    Science.gov (United States)

    van Enter, Benjamin Jasha; von Hauff, Elizabeth

    2018-04-24

    Diabetes is a global epidemic that threatens the health and well-being of hundreds of millions of people. The first step in patient treatment is to monitor glucose levels. Currently this is most commonly done using enzymatic strips. This approach suffers from several limitations, namely it requires a blood sample and is therefore invasive, the quality and the stability of the enzymatic strips vary widely, and the patient is burdened by performing the measurement themselves. This results in dangerous fluctuations in glucose levels often going undetected. There is currently intense research towards new approaches in glucose detection that would enable non-invasive continuous glucose monitoring (CGM). In this review, we explore the state-of-the-art in glucose detection technologies. In particular, we focus on the physical mechanisms behind different approaches, and how these influence and determine the accuracy and reliability of glucose detection. We begin by reviewing the basic physical and chemical properties of the glucose molecule. Although these play a central role in detection, especially the anomeric ratio, they are surprisingly often overlooked in the literature. We then review state-of-the art and emerging detection methods. Finally, we survey the current market for glucometers. Recent results show that past challenges in glucose detection are now being overcome, thereby enabling the development of smart wearable devices for non-invasive continuous glucose monitoring. These new directions in glucose detection have enormous potential to improve the quality of life of millions of diabetics, as well as offer insight into the development, treatment and even prevention of the disease.

  16. Creep behavior and threshold stress of an extruded Al-6Mg-2Sc-1Zr alloy

    International Nuclear Information System (INIS)

    Deshmukh, S.P.; Mishra, R.S.; Kendig, K.L.

    2004-01-01

    Creep experiments were performed on extruded Al-6Mg-2Sc-1Zr (wt.%) alloy in a temperature range of 423-533 K. A threshold type creep behavior was measured and explained by observed dislocation-particle interactions. The experimental threshold stress values at various temperatures were compared with existing theoretical models. None of the available models could account for the decrease in threshold creep strength with increasing temperature

  17. Experimental Investigation of Electrical Conductivity and Permittivity of SC-TiO 2 -EG Nanofluids

    Science.gov (United States)

    Fal, Jacek; Barylyak, Adriana; Besaha, Khrystyna; Bobitski, Yaroslav V.; Cholewa, Marian; Zawlik, Izabela; Szmuc, Kamil; Cebulski, Józef; żyła, Gaweł

    2016-08-01

    The paper presents experimental studies of dielectric properties of nanofluids based on ethylene glycol and SC-TiO2 nanoparticles with average size of 15-40 nm with various mass concentrations. The dielectric permittivity both real part and imaginary part as a function of temperature and frequency were measured. Also, dependence ac conductivity on frequency, temperature, and mass concentration were investigated. Based on the curves of ac conductivity, dc conductivity was calculated, and 400 % enhancement in dc conductivity was exposed.

  18. Glucose cycling is markedly enhanced in pancreatic islets of obese hyperglycemic mice

    International Nuclear Information System (INIS)

    Khan, A.; Chandramouli, V.; Ostenson, C.G.; Berggren, P.O.; Loew, H.L.; Landau, B.R.; Efendic, S.

    1990-01-01

    Pancreatic islets from fed 7-month old lean and obese hyperglycemic mice (ob/ob) were incubated with 3H2O and 5.5 mM or 16.7 mM glucose. Incorporation of 3H into the medium glucose was taken as the measure of glucose-6-P hydrolysis to glucose. Glucose utilization was measured from the yield of 3H2O from [5-3H]glucose. Only 3-4% of the glucose phosphorylated was dephosphorylated by the lean mouse islets irrespective of the glucose concentration. In contrast, the ob/ob mouse islets at 5.5 mM glucose dephosphorylated 18% of the glucose phosphorylated and 30% at 16.7 mM. Thus, the islets of hyperglycemic mice demonstrate increased glucose cycling as compared to the islets of normoglycemic lean mice

  19. The rate of lactate production from glucose in hearts is not altered by per-deuteration of glucose

    Science.gov (United States)

    Funk, Alexander M.; Anderson, Brian L.; Wen, Xiaodong; Hever, Thomas; Khemtong, Chalermchai; Kovacs, Zoltan; Sherry, A. Dean; Malloy, Craig R.

    2017-11-01

    This study was designed to determine whether perdeuterated glucose experiences a kinetic isotope effect (KIE) as glucose passes through glycolysis and is further oxidized in the tricarboxylic acid (TCA) cycle. Metabolism of deuterated glucose was investigated in two groups of perfused rat hearts. The control group was supplied with a 1:1 mixture of [U-13C6]glucose and [1,6-13C2]glucose, while the experimental group received [U-13C6,U-2H7]glucose and [1,6-13C2]glucose. Tissue extracts were analyzed by 1H, 2H and proton-decoupled 13C NMR spectroscopy. Extensive 2H-13C scalar coupling plus chemical shift isotope effects were observed in the proton-decoupled 13C NMR spectra of lactate, alanine and glutamate. A small but measureable (∼8%) difference in the rate of conversion of [U-13C6]glucose vs. [1,6-13C2]glucose to lactate, likely reflecting rates of Csbnd C bond breakage in the aldolase reaction, but conversion of [U-13C6]glucose versus [U-13C6,U-2H7]glucose to lactate did not differ. This shows that the presence of deuterium in glucose does not alter glycolytic flux. However, there were two distinct effects of deuteration on metabolism of glucose to alanine and oxidation of glucose in the TCA. First, alanine undergoes extensive exchange of methyl deuterons with solvent protons in the alanine amino transferase reaction. Second, there is a substantial kinetic isotope effect in metabolism of [U-13C6,U-2H7]glucose to alanine and glutamate. In the presence of [U-13C6,U-2H7]glucose, alanine and lactate are not in rapid exchange with the same pool of pyruvate. These studies indicate that the appearance of hyperpolarized 13C-lactate from hyperpolarized [U-13C6,U-2H7]glucose is not substantially influenced by a deuterium kinetic isotope effect.

  20. Oral glucose tolerance test and continuous glucose monitoring to assess diabetes development in cystic fibrosis patients.

    Science.gov (United States)

    Clemente León, María; Bilbao Gassó, Laura; Moreno-Galdó, Antonio; Campos Martorrell, Ariadna; Gartner Tizzano, Silvia; Yeste Fernández, Diego; Carrascosa Lezcano, Antonio

    2018-01-01

    Patients with cystic fibrosis (CF) undergo a slow and progressive process toward diabetes. Oral glucose tolerance test (OGTT) is recommended to diagnose impaired glucose levels in these patients. Continuous glucose monitoring (CGM) measures glucose profiles under real-life conditions. To compare OGTT and CGM results in CF patients. Paired OGTT and 6-day CGM profiles (146.2±9.1h/patient) were performed in 30 CF patients aged 10-18 years. According to OGTT, 14 patients had normal glucose tolerance (NGT), 14 abnormal glucose tolerance (AGT), and two cystic fibrosis-related diabetes (CFRD). In 27 patients (13 NGT, 13 AGT, 1 CFRD), CGM showed glucose values ranging from 140 to 200mg/dL during similar monitoring times (2%-14% with NGT, 1%-16.9% with AGT, and 3% with CFRD). Glucose peak levels ≥200mg/dL were seen in seven patients (3 NGT, 3 AGT, 1 CFRD). According to CGM, two patients had all glucose values under 140mg/dL (1 NGT, 1 AGT). Seventeen patients had glucose levels ranging from 140 to 200mg/dL (10 NGT, 6 AGT, 1 CFRD). Ten patients (3 NGT, 7 AGT) had glucose values ≥200mg/dL for ≤1% of the monitoring time and one (CFRD) for >1% of the monitoring time. OGTT results did not agree with those of the CGM. CGM allows for diagnosis of glucose changes not detected by OGTT. Such changes may contribute to optimize pre-diabetes management in CF patients. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. The association between estimated average glucose levels and fasting plasma glucose levels

    Directory of Open Access Journals (Sweden)

    Giray Bozkaya

    2010-01-01

    Full Text Available OBJECTIVE: The level of hemoglobin A1c (HbA1c, also known as glycated hemoglobin, determines how well a patient's blood glucose level has been controlled over the previous 8-12 weeks. HbA1c levels help patients and doctors understand whether a particular diabetes treatment is working and whether adjustments need to be made to the treatment. Because the HbA1c level is a marker of blood glucose for the previous 120 days, average blood glucose levels can be estimated using HbA1c levels. Our aim in the present study was to investigate the relationship between estimated average glucose levels, as calculated by HbA1c levels, and fasting plasma glucose levels. METHODS: The fasting plasma glucose levels of 3891 diabetic patient samples (1497 male, 2394 female were obtained from the laboratory information system used for HbA1c testing by the Department of Internal Medicine at the Izmir Bozyaka Training and Research Hospital in Turkey. These samples were selected from patient samples that had hemoglobin levels between 12 and 16 g/dL. The estimated glucose levels were calculated using the following formula: 28.7 x HbA1c - 46.7. Glucose and HbA1c levels were determined using hexokinase and high performance liquid chromatography (HPLC methods, respectively. RESULTS: A strong positive correlation between fasting plasma glucose levels and estimated average blood glucose levels (r=0.757, p<0.05 was observed. The difference was statistically significant. CONCLUSION: Reporting the estimated average glucose level together with the HbA1c level is believed to assist patients and doctors determine the effectiveness of blood glucose control measures.

  2. Glucose screening tests during pregnancy

    Science.gov (United States)

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... screening test between 24 and 28 weeks of pregnancy. The test may be done earlier if you ...

  3. 21 CFR 862.1340 - Urinary glucose (nonquantitative) test system.

    Science.gov (United States)

    2010-04-01

    ...). Urinary glucose (nonquantitative) measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, hypoglycemia, and hyperglycemia. (b) Classification. Class...

  4. A drought severity climatology for the Carpathian Region using Sc-PDSI

    Science.gov (United States)

    Antofie, Tiberiu; Naumann, Gustavo; Spinoni, Jonathan; Weynants, Melanie; Szalai, Sandor; Szentimrey, Tamas; Bihari, Zita; Vogt, Jürgen

    2013-04-01

    Monthly grids of the self-calibrating Palmer Drought Severity Index (Sc-PDSI) have been calculated for the period 1961-2010 for the Carpathian Region (17˚-27˚E, 44˚-50˚N) with a spatial resolution of 0.1˚x 0.1˚. Using the Sc-PDSI and the assumptions of the Palmer Drought Model (PDM), the approximated precipitation required for drought termination (achieved when the Sc-PDSI turns back above -0.5) and amelioration (achieved when the Sc-PDSI value turns back above -2.0) are computed for periods of 1, 3, 6, and 9 months. The Sc-PDSI is based on a modified version of the Palmer Drought Severity Index (PDSI), first introduced by Palmer (1965) with the intent to measure the cumulative departure (related to local normal conditions) of moisture supply and demand. Due to its empirically derived climatic characteristic (K) and duration factors - limited to U.S. climatic conditions - Wells et al. (2004) improved it and transformed the PDSI into the Sc-PDSI, which is more appropriate for spatial comparisons in different climatic regions. The Sc-PDSI is based on the supply-and-demand concept of a complex water budget system based on precipitation and temperature records and also on the soil characteristics at any location. The inputs used in this study are the Available Water Capacity of the soil (AWC) derived from the soil texture (European Soil Database of JRC) with a spatial resolution of 0.1˚x0.1˚, Potential Evapo-Transpiration (PET), and 6 hydrological parameters of the soil water balance: recharge, runoff, loss, and their potential values (used in the calculation of Palmer's constants to define the normal climate for the specific location, i.e. the so called CAFEC). PET has been computed using the 0.1˚x 0.1˚ gridded monthly precipitation and mean temperature for 1961-2010 provided by the CARPATCLIM project in the framework of the construction of a Climate Atlas for the Carpathian Region. The Sc-PDSI focuses on the monthly anomalies of the soil moisture, thus it

  5. Structural, electrical and magnetic properties of Sc{sup 3+} doped Mn-Zn ferrite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Angadi, V. Jagdeesha [Department of Physics, Bangalore University, Bangalore 560056 (India); Choudhury, Leema [Department of Physics, K.G. Reddy College of Engineering & Technology, Moinabad, 501504 Ranga Reddy, Telangana (India); Sadhana, K. [Department of Physics, University College of Science, Osmania University, Saifabad, Hyderabad 500004 (India); Liu, Hsiang-Lin [Department of Physics, National Taiwan Normal University, Taipei 11677, Taiwan (China); Sandhya, R. [Department of Physics, University College of Science, Osmania University, Hyderabad 500007 (India); Matteppanavar, Shidaling; Rudraswamy, B.; Pattar, Vinayak; Anavekar, R.V. [Department of Physics, Bangalore University, Bangalore 560056 (India); Praveena, K., E-mail: praveenaou@gmail.com [Department of Physics, National Taiwan Normal University, Taipei 11677, Taiwan (China)

    2017-02-15

    Sc{sup 3+} doped Mn{sub 0.5}Zn{sub 0.5}Sc{sub y}Fe{sub 2−y}O{sub 4} (y=0.00, 0.01, 0.03 and 0.05) nanoparticles were synthesized by solution combustion method using mixture of fuels were reported for the first time. The mixture of fuels plays an important role in obtaining nano crystalline, single phase present without any heat treatment. X-ray diffraction (XRD) results confirm the formation of the single-phase ferrites which crystallize in cubic spinel structure. The Fourier transform infrared spectra (FTIR) exhibit two prominent bands around 360 cm{sup −1} and 540 cm{sup −1} which are characteristic feature of spinel ferrite. The transmission electron microscope (TEM) micrographs revealed the nanoparticles to be nearly spherical in shape and of fairly uniform size. The room temperature impedance spectra (IS) and vibrating sample magnetometry (VSM) measurements were carried out in order to study the effect of doping (Sc{sup 3+}) on the characteristic properties of Mn-Zn ferrites. Further, the frequency dependent dielectric constant and dielectric loss were found to decrease with increasing multiple Sc{sup 3+} concentration. Nyquist plot in the complex impedance spectra suggest the existence of multiple electrical responses. Magnetic measurements reveals that saturation magnetization (M{sub s}), remnant magnetization (M{sub r}), magnetic moment (η{sub B}) and magnetic particle size (D{sub m}) increase with Sc{sup 3+} ion concentration up to x=0.03 and then decrease. The values of spin canting angle (α{sub Y-K}) and the magnetic particle size (D{sub m}) are found to be in the range of 68–75° and 10–19 nm respectively with Sc{sup 3+} concentration. The room temperature Mössbauer spectra were fitted with two sextets corresponding to ions at tetrahedral (A-) and octahedral (B-) sites confirms the spinel lattice. The ferromagnetic resonance (FMR) spectra's has shown that high concentration of scandium doping leads to an increase in dipolar interaction

  6. Superconductivity in ternary rare earth transition metal silicides and germanides with the Sc5Co4Si10-type structure

    International Nuclear Information System (INIS)

    Berg, L.S.

    1986-01-01

    A systematic study of the superconducting and normal state properties of some ternary rare earth transition metal silicides and germanides of the Sc 5 Co 4 Si 10 0-type is reported. Low temperature heat capacity measurements indicate the presence of a complicated phonon density of states in these structurally complex compounds. A better description of the phonon spectrum of the high T/sub c/ materials Sc 5 Rh 4 Si 10 , Sc 5 Ir 4 Si 10 , and Y 5 Os 4 Ge 10 , given by a model proposed by Junod et al., is presented and discussed. The large values of ΔC/γ/sub n/T/sub c/ and the electron-phonon coupling constant for these high T/sub c/ compounds indicate that they are strong-coupled superconductors. Relative to other ternary superconductors, many of these materials have large Debye temperatures. DC electrical resistivity measurements on these compounds show resistivity behavior deviating from those exhibited by simple metals. The rho(T) data for Y 5 Ir 4 Si 10 , Lu 5 Ir 4 Si 10 , and Y 5 Os 4 Ge 10 , indicate the presence of anomalies. Static molar magnetic susceptibility measurements performed on these compounds indicate (1) a small effective magnetic moment of 0.26μ/sub B/ on the Co atom and (2) anomalous behaviors in the Lu 5 Rh 4 Si 10 , Lu 5 Ir 4 Si 10 , Y 5 Ir 4 Si 10 , Lu 5 Ir 4 Ge 10 , and Y 5 Rh 4 Ge 10 data. Lastly, upper critical magnetic field measurements were performed on Sc 5 Co 4 Si 10 , Sc 5 Rh 4 Si 10 , Sc 5 Ir 4 Si 10 , Lu 5 Rh 4 Si 10 , Lu 5 Ir 4 Si 10 , and Y 5 Os 4 Ge 10

  7. Formation of scandium nitride (ScN) layer on gallium arsenide (GaAs) substrate using a combined technique of e-beam evaporator and ammonia annealing treatment

    Energy Technology Data Exchange (ETDEWEB)

    Yong Shee Meng, Alvin [Institute of Nano Optoelectronics Research and Technology (INOR), sains@usm, Persiaran Bukit Jambul, 11900 Bayan Lepas, Penang (Malaysia); Zainal, Norzaini, E-mail: norzaini@usm.my [Nano Optoelectronics Research and Laboratory, Universiti Sains Malaysia, sains@usm, Persiaran Bukit Jambul, 11900, Bayan Lepas, Penang (Malaysia); Hassan, Zainuriah; Ibrahim, Kamarulazizi [Institute of Nano Optoelectronics Research and Technology (INOR), sains@usm, Persiaran Bukit Jambul, 11900 Bayan Lepas, Penang (Malaysia)

    2015-12-30

    Graphical abstract: - Highlights: • Forming ScN layer using electron e-beam evaporator with successive NH{sub 3} annealing thermal has been successfully demonstrated. • NH{sub 3} annealing played the role in changing the grain structure of the ScN layer. • The existence of Sc−N bonds was confirmed by XPS measurement. • The 900 °C annealed ScN layer showed the best structural and optical characteristics. • ScN layer annealed at 980 °C exhibited poor structural and optical characteristics. - Abstract: A demonstration on a new technique of growing ScN using electron beam (e-beam) evaporator, coupled with successive ammonia (NH{sub 3}) annealing treatment is presented in this paper. The annealing temperature was varied at 750, 800, 850, 900 and 980 °C in order to obtain the best ScN layer. It was found that as the annealing temperature increased, the surface morphology of the ScN layer changed and ScN grains formed abundantly on the surface. The best surface of ScN layer was found in the 900 °C annealed sample. However, the roughness of the ScN increased with temperature. The photoluminescence (PL) peak of the near-to-band-edge (NBE) of ScN was observable in all samples and its intensity was the highest in the 900 °C annealed sample. Note that when the annealing treatment was conducted at 980 °C, the GaN PL peak is observable. Raman peaks of TO(X) of ScN were much evident at the annealing temperature above 900 °C. The formation of Sc−N bonds was confirmed by X-ray spectroscopy (XPS) measurement. In the end of this work, we propose that the formation of ScN using the above techniques was successful, with thermal annealing at the temperature of 900 °C.

  8. Preliminary evidence that glucose ingestion facilitates prospective memory performance.

    Science.gov (United States)

    Riby, Leigh M; Law, Anna S; McLaughlin, Jennifer; Murray, Jennifer

    2011-05-01

    Previous research has found that the ingestion of glucose boosts task performance in the memory domain (including tasks tapping episodic, semantic, and working memory). The present pilot study tested the hypothesis that glucose ingestion would enhance performance on a test of prospective memory. In a between-subjects design, 56 adults ranging from 17 to 80 years of age performed a computerized prospective memory task and an attention (filler) task after 25 g of glucose or a sweetness-matched placebo. Blood glucose measurements were also taken to assess the impact of individual differences on glucose regulation. After the drink containing glucose, cognitive facilitation was observed on the prospective memory task after excluding subjects with impaired fasting glucose level. Specifically, subjects receiving glucose were 19% more accurate than subjects receiving a placebo, a trend that was marginally nonsignificant, F₁,₄₁ = 3.4, P = .07, but that had a medium effect size, d = 0.58. Subjects receiving glucose were also significantly faster on the prospective memory task, F₁,₃₅ = 4.8, P glucose (indicative of poor glucose regulation) was associated with slower prospective memory responding, F₁,₃₅ = 4.4, P memory and executive functioning can benefit from the increased provision of glucose to the brain. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Determination of Hf, Sc and Y in geological samples together with the rare-earth elements

    International Nuclear Information System (INIS)

    Lihareva, N.; Delaloye, M.

    1997-01-01

    A method is described for the determination of Hf, Sc and Y simultaneously with the REE in geological materials. An earlier method for REE separation from major elements was studied with the aim to apply it also to the determination of Hf, Sc and Y. Sample decomposition was carried out by melting with LiBO 2 . The method involves separation and concentration stages, using the cation-exchange resin DOWEX AG 50W-X8. Matrix elements were eluted with 2 mol/l HCl, whereas 6 mol/l HNO 3 with oxalic acid and 8 mol/l HNO 3 were used to elute the elements to be determined. Some of the matrix elements could not be completely removed. This effect as well as the recovery rates of the determined elements were investigated. The measurements were performed by ICP-AES. Spectral interferences were also tested. (orig.). With 1 tab

  10. Electronic structure and magnetic properties of Sc doped EuO thin films

    Energy Technology Data Exchange (ETDEWEB)

    Reisner, Andreas; Altendorf, Simone; Chang, Chun-Fu; Tjeng, Liu Hao [Max-Planck-Institute for Chemical Physics of Solids, Noethnitzer Str.40, 01187 Dresden (Germany); Lin, Hong-Ji; Chen, Chien-Te [National Synchrotron Radiation Research Center, Hsin-Ann Road, 30076 Hsinchu, Taiwan (China)

    2013-07-01

    Europium monoxide is a ferromagnetic semiconductor with a Curie temperature T{sub C} of 69 K. Upon doping the material can show an increase of the Curie temperature, a metal-to-insulator transition and a high spin polarization of the charge carriers. Applying pressure can also enhance T{sub C}. Mostly other trivalent rare earth metals are used as dopant. Here we set out to explore the possibility of using transition metals as dopants. As a start we focus on the non magnetic Sc ions. We are able to achieve excellent crystalline growth of Sc-doped EuO thin films on YSZ (001) substrates using molecular beam epitaxy. We report our results on the crystal structure as characterized by RHEED and LEED, the electronic structure as determined by XPS and ARPES, and on the magnetic properties as measured by SQUID.

  11. Primary beam-loading tests on DC-SC photoinjector at Peking University

    International Nuclear Information System (INIS)

    Hao Jiankui; Lu Xiangyang; Ding, Yuantao; Quan Shengwen; Huang Senlin; Zhao Kui; Zhang Baocheng; Wang Lifang; Lin Lin; Jiao Fei; Wang Guimei; Xie Datao; Zhu Feng; Xiao Binping; Xiang Rong; Chen Jia'er

    2006-01-01

    The DC-SC photoinjector is a compact electron gun integrating a DC pierce gun with a 1.3 GHz 1+1/2 cell superconducting cavity. A test facility of the DC-SC photoinjector had been installed in Peking University and beam-loading tests at 4.4 K have been finished. To date the gradient of 6 MV/m has been achieved. The maximum energy gain is 1.1 MeV at 4.4 K. With average beam current of 270 μA, the measured rms emittance is about 5 mm mrad at the beam energy of 500 keV. In this paper some of the experimental results are summarized

  12. Optical properties and radiation response of Ce3+-doped GdScO3 crystals

    International Nuclear Information System (INIS)

    Yamaji, Akihiro; Fujimoto, Yutaka; Futami, Yoshisuke; Yokota, Yuui; Kurosawa, Shunsuke; Kochurikhin, Vladimir; Yanagida, Takayuki; Yoshikawa, Akira

    2012-01-01

    10%-Ce doped GdScO 3 perovskite type single crystal was grown by the Czochralski process. The Ce concentration in the crystal was measured. No impurity phases were observed by powder X-ray diffraction analysis. We evaluated the optical and radiation properties of the grown crystal. Ce:GdScO 3 crystal showed photo- and radio-luminescence peaks due to Ce 3+ of 5d-4f transition and colour centre. The photoluminescence decay time was sub-ns order. The relative light yield under 5.5 MeV alpha-ray excitation was calculated to be approximately 9% of BGO. (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. Ultrasonic standing wave preparation of a liquid cell for glucose measurements in urine by midinfrared spectroscopy and potential application to smart toilets.

    Science.gov (United States)

    Yamamoto, Naoyuki; Kawashima, Natsumi; Kitazaki, Tomoya; Mori, Keita; Kang, Hanyue; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro

    2018-05-01

    Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong absorption of midinfrared light by water. Conventional liquid cells or fixed cells are prepared based on the liquid membrane method and solution technique, but these are not quantitative and are difficult to set up and clean. We generated an ultrasonic standing wave reflection plane in a sample and produced an ultrasonic liquid cell. In this cell, the thickness of the optical path length was adjustable, as in the conventional method. The reflection plane could be generated at an arbitrary depth and internal reflected light could be detected by changing the frequency of the ultrasonic wave. We could generate refractive index boundaries using the density difference created by the ultrasonic standing wave. Creation of the reflection plane in the sample was confirmed by optical coherence tomography. Using the proposed method and midinfrared spectroscopy, we discriminated between normal urine samples spiked with glucose at different concentrations and obtained a high correlation coefficient. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  14. Authenticated, private, and secured smart cards (APS-SC)

    Science.gov (United States)

    Szu, Harold; Mehmood, Amir

    2006-04-01

    From historical perspective, the recent advancements in better antenna designs, low power circuitry integrations and inexpensive fabrication materials have made possible a miniature counter-measure against Radar, a clutter behaving like a fake target return called Digital Reflection Frequency Modulation (DRFM). Such a military counter-measure have found its way in the commerce as a near field communication known as Radio Frequency Identification (RFID), a passive or active item tag T attached to every readable-writable Smart Card (SC): Passports ID, medical patient ID, biometric ID, driver licenses, book ID, library ID, etc. These avalanche phenomena may be due to the 3 rd Gen phones seeking much more versatile & inexpensive interfaces, than the line-of-sight bar-code optical scan. Despite of the popularity of RFID, the lacking of Authenticity, Privacy and Security (APS) protection restricted somewhat the wide spread commercial, financial, medical, legal, and militarily applications. Conventional APS approach can obfuscate a private passkey K of SC with the tag number T or the reader number R, or both, i.e. only T*K or R*K or both will appear on them, where * denotes an invertible operation, e.g. EXOR, but not limited to it. Then, only the authentic owner, knowing all, can inverse the operation, e.g. EXOR*EXOR= I to find K. However, such an encryption could be easily compromised by a hacker seeking exhaustively by comparison based on those frequently used words. Nevertheless, knowing biological wetware lesson for power of pairs sensors and Radar hardware counter-measure history, we can counter the counter-measure DRFM, instead using one RFID tag per SD, we follow the Nature adopting two ears/tags, e.g. each one holding portions of the ID or simply two different ID's readable only by different modes of the interrogating reader, followed by brain central processor in terms of nonlinear invertible shufflers mixing two ID bits. We prefer to adopt such a hardware

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication ... Learning at Camp Find a Camp Fundraising Events Step Out Walk to Stop Diabetes Tour de Cure ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... EXPO Volunteer Opportunities Sponsorship and Exhibit Opportunities Camp ... when ketones are present may make your blood glucose level go even higher. You'll need to work with your doctor ...

  20. CSF glucose test

    Science.gov (United States)

    ... in the space surrounding the spinal cord and brain. ... Abnormal results include higher and lower glucose levels. Abnormal results may be due to: Infection (bacterial or fungus) Inflammation of the central nervous system Tumor

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Clinical Practice Guidelines Patient Education Materials Scientific Sessions Journals for Professionals Professional Books Patient Access to Research ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  4. Nocturnal continuous glucose monitoring

    DEFF Research Database (Denmark)

    Bay, Christiane; Kristensen, Peter Lommer; Pedersen-Bjergaard, Ulrik

    2013-01-01

    Abstract Background: A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... for energy. When your body breaks down fats, waste products called ketones are produced. Your body cannot ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... breast cancer and AIDS combined. Your gift today will help us get closer to curing diabetes and ... blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. How ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers ... updated, this is the "take-you-by-the-hand" guide that will become a trusted friend and ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Day in the Life of Diabetes Famous People Working to Stop Diabetes Common Terms Diabetes Statistics Infographics ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Superfoods Non-starchy Vegetables Grains and Starchy Vegetables Fats Alcohol What Can I Drink? Fruit Dairy Food ... glucose for fuel, so your body breaks down fats to use for energy. When your body breaks ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... someone new is diagnosed. Diabetes causes more deaths a year than breast cancer and AIDS combined. Your gift today will help ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Care > Blood Glucose Testing Share: Print Page Text Size: A A A Listen En Español Hyperglycemia ( ... compact USB drives that can carry a person's full medical record for use in an emergency. How ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... for Association Events Messaging Tools Recruiting Advocates Local Market Planning Training Webinars News & Events Advocacy News Call ... Care > Blood Glucose Testing Share: Print Page Text Size: A A A Listen En Español Hyperglycemia (High ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... blood glucose level go even higher. You'll need to work with your doctor to find the ... lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness of breath Breath ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... your blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. ... to detect hyperglycemia so you can treat it early — before it gets worse. If you're new ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Email: Sign Up Thank you for signing up ' + ' '); $('.survey-form').show(); }, success: function (data) { $('#survey-errors').remove(); $('. ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ... Living With Diabetes Recently Diagnosed Treatment & Care Complications Health ... EXPOs Awareness Programs Wellness Lives Here Become a Member American ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your best bet is to practice good diabetes management and learn to detect hyperglycemia so you can ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  5. [A comparison of post-surgical plasma glucose levels in patients on fluids with different glucose concentrations].

    Science.gov (United States)

    Martínez Carapeto, Isabel; López Castilla, José Domingo; Fresneda Gutiérrez, Reyes

    2017-11-11

    To compare plasma glucose levels and incidence of hyperglycaemia in the post-operative period after general surgery using fluids with different glucose. A randomised, open-label, non-blind, clinical trial was conducted on patients admitted to Paediatric Intensive Care Unit after elective surgery. The inclusion criteria were from 6 months to 14 years of age, with a weight greater than 6kg, onset glucose level >60mg/dL, and a signed informed consent, with no oral intake and maintenance intravenous fluid therapy using fluids with 3.3% or 5% glucose. Plasma glucose levels were measured before surgery, on admission, and 8, 24, and 48h, with the mean glucose levels and incidence of hyperglycaemia (glucose level >150mg/dL) in both groups being compared. A total of 60 patients received glucose/saline 1/3 (51mEq/L sodium and 33g/L glucose), and 70 glucose/saline 5/0.9% (154mEq/L sodium and 50g/L glucose). Mean glucose levels were higher in the group receiving glucose 5%, with no statistical difference. There was no significant difference in the incidence of hyperglycaemia; 8h: 26% in the 3.3% group vs. 21.3% in the 5% group (P=.63); 24h: 20% vs. 22.7% (P=.8); and 48h: 19% vs. 23.1% (P=.78). The use of fluids with 3.3% glucose in the post-operative period of general surgery maintains mean glucose levels in a similar range to that of patients receiving fluids with 5% glucose, with no difference in the incidence of hyperglycaemia. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  6. One-neutron knockout from {sup 51-55}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Schwertel, S.; Maierbeck, P.; Gernhaeuser, R.; Bildstein, V.; Boehmer, M.; Eppinger, K.; Faestermann, T.; Friese, J.; Fabbietti, L.; Maier, L.; Winkler, S. [Technische Universitaet Muenchen, Physik Department E12, Garching (Germany); Kruecken, R. [Technische Universitaet Muenchen, Physik Department E12, Garching (Germany); TRIUMF, Vancouver (Canada); University of British Columbia, Department of Physics and Astronomy, Vancouver (Canada); Kroell, T. [Technische Universitaet Muenchen, Physik Department E12, Garching (Germany); Technische Universitaet Darmstadt, Institut fuer Kernphysik, Darmstadt (Germany); Alvarez-Pol, H.; Benjamim, E.A.; Benlliure, J.; Caamano, M.; Cortina-Gil, D.; Gascon, M.; Kurtukian, T.; Perez, D.; Rodriguez-Tajes, C. [Universidade de Santiago de Compostela, Departamento de Fisica de Particulas, Santiago de Compostela (Spain); Aksouh, F.; Aumann, T.; Behr, K.; Boretzky, K.; Bruenle, A.; Chatillon, A.; Chulkov, L.V.; Geissel, H.; Gerl, J.; Gorska, M.; Kojouharov, I.; Klimkiewicz, A.; Kurz, N.; Nociforo, C.; Schaffner, H.; Simon, H.; Stanoiu, M.; Suemmerer, K.; Weick, H. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Borge, M.J.G.; Pascual-Izarra, C.; Perea, A.; Tengblad, O. [CSIC, Instituto de Estructura de la Materia, Madrid (Spain); Buerger, A. [University of Oslo, SAFE/OCL, Oslo (Norway); CEA, Gif-sur-Yvette (France); Casarejos, E.; Brown, B.A. [University of Vigo, Vigo (Spain); Enders, J.; Schrieder, G. [Technische Universitaet Darmstadt, Institut fuer Kernphysik, Darmstadt (Germany); Hansen, P.G. [Michigan State University, NSCL, East Lansing, Michigan (United States); Jonson, B.; Nyman, G. [Chalmers Tekniska Hoegskola och Goeteborgs Universitet, Experimentell Fysik, Goeteborg (Sweden); Kanungo, R. [TRIUMF, Vancouver (Canada); GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Saint Mary' s University, Halifax (Canada); Kiselev, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Johannes Gutenberg Universitaet, Mainz (Germany); Paul Scherrer Institut, Villigen (Switzerland); Larsson, K. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Chalmers Tekniska Hoegskola och Goeteborgs Universitet, Experimentell Fysik, Goeteborg (Sweden); Le Bleis, T. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); IN2P3-CNRS/Universite Louis Pasteur, Institut Pluridisciplinaire Hubert Curien, Strasbourg Cedex 2 (France); Mahata, K. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Paul Scherrer Institut, Villigen (Switzerland); Nilsson, T. [Technische Universitaet Darmstadt, Institut fuer Kernphysik, Darmstadt (Germany); Chalmers Tekniska Hoegskola och Goeteborgs Universitet, Experimentell Fysik, Goeteborg (Sweden); Prochazka, A. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Comenius University, Faculty of Mathematics and Physics, Bratislava (Slovakia); Rossi, D. [Johannes Gutenberg Universitaet, Mainz (Germany); Sitar, B. [Comenius University, Faculty of Mathematics and Physics, Bratislava (Slovakia); Otsuka, T. [University of Tokyo, Hongo, Bunkyo-ku, Department of Physics, Tokyo (Japan); Tostevin, J.A. [University of Surrey, Department of Physics, Faculty of Engineering and Physical Sciences, Guildford (United Kingdom); Rae, W.D.M. [Garsington, Oxfordshire (United Kingdom)

    2012-12-15

    Results are presented from a one-neutron knockout experiment at relativistic energies of {approx} 420 A MeV on {sup 51-55}Sc using the GSI Fragment Separator as a two-stage magnetic spectrometer and the MINIBALL array for gamma-ray detection. Inclusive longitudinal momentum distributions and cross-sections were measured enabling the determination of the contributions corresponding to knockout from the {nu}p{sub 1/2}, {nu}p{sub 3/2}, (L = 1) and {nu}f{sub 7/2}, {nu}f{sub 5/2} (L = 3) neutron orbitals. The observed L = 1 and L = 3 contributions are compared with theoretical cross-sections using eikonal knockout theory and spectroscopic factors from shell model calculations using the GXPF1A interaction. The measured inclusive knockout cross-sections generally follow the trends expected theoretically and given by the spectroscopic strength predicted from the shell model calculations. However, the deduced L = 1 cross-sections are generally 30-40% higher while the L = 3 contributions are about a factor of two smaller than predicted. This points to a promotion of neutrons from the {nu}f{sub 7/2} to the {nu}p{sub 3/2} orbital indicating a weakening of the N = 28 shell gap in these nuclei. While this is not predicted for the phenomenological GXPF1A interaction such a weakening is predicted by recent calculations using realistic low-momentum interactions V{sub low} {sub k} obtained by evolving a chiral N3LO nucleon-nucleon potential. (orig.)

  7. Thermodynamic modeling of the Sc-Zn system coupled with first-principles calculation

    Directory of Open Access Journals (Sweden)

    Tang C.

    2012-01-01

    Full Text Available The Sc-Zn system has been critically reviewed and assessed by means of CALPHAD (CALculation of PHAse Diagram approach. By means of first-principles calculation, the enthalpies of formation at 0 K for the ScZn, ScZn2, Sc17Zn58, Sc3Zn17 and ScZn12 have been computed with the desire to assist thermodynamic modeling. A set of self-consistent thermodynamic parameters for the Sc-Zn system is then obtained. The calculated phase diagram and thermodynamic properties agree well with the experimental data and first-principles calculations, respectively.

  8. Comparative study of Tm-doped and Tm-Sc co-doped Lu3Al5O12 scintillator

    International Nuclear Information System (INIS)

    Sugiyama, Makoto; Yanagida, Takayuki; Fujimoto, Yutaka

    2014-01-01

    The crystals of Tm doped and Tm-Sc co-doped Lu 3 Al 5 O 12 (LuAG) grown by the floating zone (FZ) method were examined for their optical and scintillation properties. In transmittance spectra, strong absorption lines due to Tm 3+ 4f–4f transitions were observed. X-ray excited radioluminescence spectra were measured and broad and sharp emission peaks were detected. The former one was attributed to Sc 3+ and the latter one was due to Tm 3+ 4f–4f transitions. Scintillation yield enhancement due to Sc co-doping was observed by means of 137 Cs pulse height spectra. Scintillation decay times were several tens of μs under pulse X-ray excitation. - Highlights: • LuAG:Tm and LuAG:Tm, Sc single crystals have been grown by the FZ method. • Tm 3+ 4f–4f absorption has been observed in transmittance spectra. • Scintillation yield of Tm-doped LuAG has been enhanced by Sc co-doping

  9. The ternary systems Sc-Sm(Dy)-Si at 870 K

    International Nuclear Information System (INIS)

    Kotur, B.Ya.; Mokra, I.Ya.; Toporinskij, A.Ya.

    1991-01-01

    Isothermal cross sections of the ternary systems Sc-Sm-Si and Sc-Dy-Si at 870 K have been plotted. Investigation of scandium and disprosium in ternary systems have been examined by X-ray diffraction and microstructure analysis. Besides literary data on binary systems Sc-Si, Sm-Si, Dy-Si have been used. Formation of limited (Sc-Sm-Si, Sc-Dy-Si) and continuous (Sc-Dy-Si) solid solutions based on bisilicides of Sc and Sm(Dy) is discovered. Two and five ternary compounds in Sc-Sm-Si and Sc-Dy-Si systems have been determined and their crystal structure has been established. When investigating of Sc-(rare earth element)-Si ternary systems and should take into account the specific interaction of scandium and samarium with REE

  10. A randomized controlled trial to compare the effects of sulphonylurea gliclazide MR (modified release) and the DPP-4 inhibitor vildagliptin on glycemic variability and control measured by continuous glucose monitoring (CGM) in Brazilian women with type 2 diabetes.

    Science.gov (United States)

    Vianna, Andre Gustavo Daher; Lacerda, Claudio Silva; Pechmann, Luciana Muniz; Polesel, Michelle Garcia; Marino, Emerson Cestari; Faria-Neto, Jose Rocha

    2018-05-01

    This study aims to evaluate whether there is a difference between the effects of vildagliptin and gliclazide MR (modified release) on glycemic variability (GV) in women with type 2 diabetes (T2DM) as evaluated by continuous glucose monitoring (CGM). An open-label, randomized study was conducted in T2DM women on steady-dose metformin monotherapy which were treated with 50 mg vildagliptin twice daily or 60-120 mg of gliclazide MR once daily. CGM and GV indices calculation were performed at baseline and after 24 weeks. In total, 42 patients (age: 61.9 ± 5.9 years, baseline glycated hemoglobin (HbA1c): 7.3 ± 0.56) were selected and 37 completed the 24-week protocol. Vildagliptin and gliclazide MR reduced GV, as measured by the mean amplitude of glycemic excursions (MAGE, p = 0.007 and 0.034, respectively). The difference between the groups did not reach statistical significance. Vildagliptin also significantly decreased the standard deviation of the mean glucose (SD) and the mean of the daily differences (MODD) (p = 0.007 and 0.030). Vildagliptin and gliclazide MR similarly reduced the MAGE in women with T2DM after 24 weeks of treatment. Further studies are required to attest differences between vildagliptin and gliclazide MR regarding glycemic variability. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring.

    Science.gov (United States)

    Ugi, Satoshi; Maegawa, Hiroshi; Morino, Katsutaro; Nishio, Yoshihiko; Sato, Toshiyuki; Okada, Seiki; Kikkawa, Yasuo; Watanabe, Toshihiro; Nakajima, Hiromu; Kashiwagi, Atsunori

    2016-08-01

    Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.

  12. Adjuvant and immunostimulatory effects of a D-galactose-binding lectin from Synadenium carinatum latex (ScLL in the mouse model of vaccination against neosporosis

    Directory of Open Access Journals (Sweden)

    Cardoso Mariana R D

    2012-10-01

    Full Text Available Abstract Vaccination is an important control measure for neosporosis that is caused by a coccidian parasite, Neospora caninum, leading to abortion and reproductive disorders in cattle and serious economic impacts worldwide. A D-galactose-binding lectin from Synadenium carinatum latex (ScLL was recently described by our group with potential immunostimulatory and adjuvant effects in the leishmaniasis model. In this study, we evaluated the adjuvant effect of ScLL in immunization of mice against neosporosis. First, we investigated in vitro cytokine production by dendritic cells stimulated with Neospora lysate antigen (NLA, ScLL or both. Each treatment induced TNF-α, IL-6, IL-10 and IL-12 production in a dose-dependent manner, with synergistic effect of NLA plus ScLL. Next, four groups of C57BL/6 mice were immunized with NLA + ScLL, NLA, ScLL or PBS. The kinetics of antibody response showed a predominance of IgG and IgG1 for NLA + ScLL group, whereas IgG2a response was similar between NLA + ScLL and NLA groups. Ex vivo cytokine production by mouse spleen cells showed the highest IFN-γ/IL-10 ratio in the presence of NLA stimulation for mice immunized with NLA + ScLL and the lowest for those immunized with ScLL alone. After parasite challenge, mice immunized with NLA + ScLL or ScLL alone presented higher survival rates (70-80% and lower brain parasite burden as compared to PBS group, but with no significant changes in morbidity and inflammation scores. In conclusion, ScLL combined with NLA was able to change the cytokine profile induced by the antigen or lectin alone for a Th1-biased immune response, resulting in high protection of mice challenged with the parasite, but with low degree of inflammation. Both features may be important to prevent congenital neosporosis, since protection and low inflammatory response are necessary events to guide towards a successful pregnancy.

  13. The effects of glucose ingestion and glucose regulation on memory performance in older adults with mild cognitive impairment.

    Science.gov (United States)

    Riby, L M; Marriott, A; Bullock, R; Hancock, J; Smallwood, J; McLaughlin, J

    2009-04-01

    Previous research investigating the impact of glucose ingestion and/or improvements in glucose regulation has found selective cognitive facilitation on episodic memory tasks in successful ageing and dementia. The present study aimed to extend this research to mild cognitive impairment (MCI). In a repeated-measures design, 24 older adults with and 24 older adults without MCI performed a battery of memory and attention tasks after 25 g of glucose or a sweetness matched placebo. In addition, to assess the impact of individual differences in glucose regulation, blood glucose measurements were taken throughout the testing session. Consistent with previous research, cognitive facilitation was observed for episodic memory tasks only in both successful ageing and MCI. Older adults with MCI had a similar glucose regulatory response as controls but their fasting levels were elevated. Notably, higher levels of blood glucose were associated with impaired memory performance in both the glucose and placebo conditions. Importantly, both blood glucose and memory performance indices were significant predictors of MCI status. The utility of glucose supplementation and the use of glucose regulation as a biological marker are discussed in relation to these data.

  14. Paracyclophane functionalized with Sc and Li for hydrogen storage

    Science.gov (United States)

    Sathe, Rohit Y.; Dhilip Kumar, T. J.

    2018-01-01

    Li and Sc metals functionalized on the delocalized π -electrons of benzene rings in [2,2]paracyclophane structure are studied for hydrogen storage efficiency by using the M06 DFT functional with 6-311G(d,p) basis set. It is found that Sc and Li functionalized [2,2]paracyclophane complexes can hold up to 10 H2 molecules and 8 H2 molecules by Kubas-Niu-Jena interaction and charge polarization mechanism with hydrogen weight percentage of 11.4 and 13.5, respectively. Molecular dynamics simulation at various temperatures showed appreciable thermal stability while the chemical potential calculation at room temperature reveals that Sc functionalized [2,2]paracyclophane system will be a promising hydrogen storage material.

  15. Comparative investigation of tungsten inert gas and friction stir welding characteristics of Al-Mg-Sc alloy plates

    International Nuclear Information System (INIS)

    Zhao, Juan; Jiang, Feng; Jian, Haigen; Wen, Kang; Jiang, Long; Chen, Xiaobo

    2010-01-01

    Al-Mg-Sc alloy plates were welded by FSW and TIG welding. The effect of welding processes on mechanical properties of Al-Mg-Sc welded joints was analyzed based on optical microscopy, transmission electron microscopy, tensile testing and Vickers microhardness measurements. The results show that the mechanical properties of FSW welded joint are much better than those of TIG welded joint; the strength coefficient of FSW joint is up to 94%. Moreover, tensile strength and yield strength of FSW joint are 19% and 31% higher than those of TIG joint, respectively, which are attributed to the preservation of cold working microstructures in the process of FSW. Due to the low welding temperature during FSW process and the excellent thermal stability of Al 3 (Sc, Zr) particles, the cold working microstructures can be well preserved. In addition, the FSW joint have asymmetric microstructures and mechanical properties, which are not observed in TIG welded joint.

  16. Cerebral glucose utilization after vasopressin barrel rotation or bicuculline seizures

    International Nuclear Information System (INIS)

    Wurpel, J.; Dundore, R.; Bryan, R.; Keil, L.; Severs, W.B.

    1986-01-01

    Intraventricular (ivt) arginine vasopressin (AVP) causes a violent motor behavior termed barrel rotation (BR). AVP-BR is affected by visual/vestibular sensory input and may be related to other CNS motor disorders (seizures). Local cerebral glucose utilization (LCGU) was compared in SD rats during AVP-BR and bicuculline (BIC) seizures. Three groups were used: saline-ivt; AVP-ivt 0.5 μg; BIC-5.5 mg/kg,sc. 14 C-glucose (40 μCI iv) was injected 15 sec. after ivt-saline or AVP or onset of BIC seizures. Rats were decapitated 10 min. after 14 C-glucose. Brains were removed and dissected into 19 regions which were digested and glucose uptake quantified by liquid scintillation counting. LCGU was significantly increased in all CNS areas during BIC seizures vs controls (21-92%; p < 0.05 ANOVA). LCGU exhibits variable (upward arrow, downward arrow) changes in discrete areas during AVP-BR (p < .05). Glucose uptake increased in: cortex-olfactory (21%), sensory (9%), motor (8%) cerebellum-rt (13%) and 1t (17%) hemispheres, vermis (6%); pyramidal tract (6%); mesencephalon (5%); and pons (8%). Two areas decreased LCGU during AVP-BR: auditory cortex (-8%) and hippocampus (-11%). AVP-BR exhibits distinct changes in LCGU vs BIC seizures

  17. Pathophysiological Characteristics Underlying Different Glucose Response Curves

    DEFF Research Database (Denmark)

    Hulman, Adam; Witte, Daniel R; Vistisen, Dorte

    2018-01-01

    different glucose curve patterns and studied their stability and reproducibility over 3 years of follow-up. RESEARCH DESIGN AND METHODS: We analyzed data from participants without diabetes from the observational cohort from the European Group for the Study of Insulin Resistance: Relationship between Insulin...... and secretion. The glucose patterns identified at follow-up were similar to those at baseline, suggesting that the latent class method is robust. We integrated our classification model into an easy-to-use online application that facilitates the assessment of glucose curve patterns for other studies. CONCLUSIONS...... Sensitivity and Cardiovascular Disease study; participants had a five-time point OGTT at baseline (n = 1,443) and after 3 years (n = 1,045). Measures of insulin sensitivity and secretion were assessed at baseline with a euglycemic-hyperinsulinemic clamp and intravenous glucose tolerance test. Heterogeneous...

  18. Evaluation of Postprandial Glucose Excursion Using a Novel Minimally Invasive Glucose Area-Under-the-Curve Monitoring System

    OpenAIRE

    Kuranuki, Sachi; Sato, Toshiyuki; Okada, Seiki; Hosoya, Samiko; Seko, Akinobu; Sugihara, Kaya; Nakamura, Teiji

    2013-01-01

    Objective: To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Methods: Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the are...

  19. Band structure of the quaternary Heusler alloys ScMnFeSn and ScFeCoAl

    Science.gov (United States)

    Shanthi, N.; Teja, Y. N.; Shaji, Shephine M.; Hosamani, Shashikala; Divya, H. S.

    2018-04-01

    In our quest for materials with specific applications, a theoretical study plays an important role in predicting the properties of compounds. Heusler alloys or compounds are the most studied in this context. More recently, a lot of quaternary Heusler compounds are investigated for potential applications in fields like Spintronics. We report here our preliminary study of the alloys ScMnFeSn and ScFeCoAl, using the ab-initio linear muffin-tin orbital method within the atomic sphere approximation (LMTO-ASA). The alloy ScMnFeSn shows perfect half-metallicity, namely, one of the spins shows a metallic behaviour and the other spin shows semi-conducting behaviour. Such materials find application in devices such as the spin-transfer torque random access memory (STT-MRAM). In addition, the alloy ScMnFeSn is found to have an integral magnetic moment of 4 µB, as predicted by the Slater-Pauling rule. The alloy ScFeCoAl does not show half-metallicity.

  20. Student center approach in maths and sc

    African Journals Online (AJOL)

    User

    teachers were effectively utilizing prior knowledge of learners in starting their ... rated as poor in making classroom environment conducive for group learning. .... measure. These all are geared toward enhancing students' learning of ... They need to scaffold each other learning ... In short, the following schools ..... interaction.

  1. Lightweight hydrogen-storage material Mg0.65Sc0.35D2 studied with 2H and 2H–{45Sc} MAS NMR exchange spectroscopy

    NARCIS (Netherlands)

    Srinivasan, S.; Magusin, P.C.M.M.

    2011-01-01

    Using double-quantum 2H MAS NMR with 45Sc recoupling and Bloch–Siegert compensated 2H–{45Sc} TRAPDOR we have identified the overlapping NMR signals of deuterium with and without scandium neighbors in Mg0.65Sc0.35D2, a candidate lightweight material for hydrogen storage. At room temperature we also

  2. Low-β SC linacs: past, present, and future

    International Nuclear Information System (INIS)

    Bollinger, L. M.

    1998-01-01

    This paper is a general review of superconducting low-β technology and applications from its beginning in 1969 into the near-term future. The emphasis is on studies of accelerating resonators and on SC linacs that boost the energy of heavy-ion beams from tandem electrostatic accelerators used for nuclear-physics research. Other topics are positive-ion SC injectors to replace tandems and the need for accelerating structures with β outside of the present proven range, 0.008 < β < 0.2

  3. Bayesian narrowband interference mitigation in SC-FDMA

    KAUST Repository

    Ali, Anum; Masood, Mudassir; Al-Ghadhban, Samir; Al-Naffouri, Tareq Y.

    2015-01-01

    This paper presents a novel narrowband interference (NBI) mitigation scheme for SC-FDMA systems. The proposed scheme exploits the frequency domain sparsity of the unknown NBI signal and adopts a low complexity Bayesian sparse recovery procedure. In practice, however, the sparsity of the NBI is destroyed by a grid mismatch between NBI sources and SC-FDMA system. Towards this end, an accurate grid mismatch model is presented and a sparsifying transform is utilized to restore the sparsity of the unknown signal. Numerical results are presented that depict the suitability of the proposed scheme for NBI mitigation.

  4. Thermoelectric performance of functionalized Sc2C MXenes

    KAUST Repository

    Kumar, S.

    2016-07-05

    Functionalization of the MXene Sc2C, which has the rare property to realize semiconducting states for various functionalizations including O, F, and OH, is studied with respect to the electronic and thermal behavior. The lowest lattice thermal conductivity is obtained for OH functionalization and an additional 30% decrease can be achieved by confining the phonon mean free path to 100 nm. Despite a relatively low Seebeck coefficient, Sc2C(OH)2 is a candidate for intermediate-temperature thermoelectric applications due to compensation by a high electrical conductivity and very low lattice thermal conductivity.

  5. Bayesian narrowband interference mitigation in SC-FDMA

    KAUST Repository

    Ali, Anum

    2015-08-12

    This paper presents a novel narrowband interference (NBI) mitigation scheme for SC-FDMA systems. The proposed scheme exploits the frequency domain sparsity of the unknown NBI signal and adopts a low complexity Bayesian sparse recovery procedure. In practice, however, the sparsity of the NBI is destroyed by a grid mismatch between NBI sources and SC-FDMA system. Towards this end, an accurate grid mismatch model is presented and a sparsifying transform is utilized to restore the sparsity of the unknown signal. Numerical results are presented that depict the suitability of the proposed scheme for NBI mitigation.

  6. Radiation protection Group (SC/RP) desperately seeking...

    CERN Document Server

    A. Hervé, Y. Donjoux / SC

    2006-01-01

    We are trying to trace two transit permits (passavants), which constitute the customs clearance documentation for two 'AD6'portable radiation detectors. The two permits (No. 1308 and No. 1309) were sent in the same internal mail envelope towards the middle of March 2006 but never reached their final destination. After weeks of searching in vain, we are now appealing for your help. If you have these two permits in your possession, please get in touch with us. Many thanks in advance. A.HERVE - SC/RP- ( 163168 / 70927) Y.DONJOUX - SC/RP - (160105 / 73171)

  7. Thermoelectric performance of functionalized Sc2C MXenes

    KAUST Repository

    Kumar, S.; Schwingenschlö gl, Udo

    2016-01-01

    Functionalization of the MXene Sc2C, which has the rare property to realize semiconducting states for various functionalizations including O, F, and OH, is studied with respect to the electronic and thermal behavior. The lowest lattice thermal conductivity is obtained for OH functionalization and an additional 30% decrease can be achieved by confining the phonon mean free path to 100 nm. Despite a relatively low Seebeck coefficient, Sc2C(OH)2 is a candidate for intermediate-temperature thermoelectric applications due to compensation by a high electrical conductivity and very low lattice thermal conductivity.

  8. Mise en scène ja kertova lavastus

    OpenAIRE

    Bruun, Ida

    2013-01-01

    Tämä opinnäytetyö tutkii mise en scèneä ja lavastuksen kerronnallista vaikutusta elokuvassa. Työ on toteutettu toiminnallisena ja koostuu kirjallisesta osasta ja teososasta. Teososa on vuonna 2012 ensi-iltansa saanut fiktiivinen lyhytelokuva Varjelus. Toimin elokuvassa lavastajana ja rekvisitöörinä. Kirjallinen osuus alkaa käsittelemällä mise en scènen, eli ’näyttämöllepanon’ määritelmää ja sen syntyä elokuvalliseksi konseptiksi. Työ etenee esittelemään ja tarkastelemaan käsitteen eri vis...

  9. Development of Field-Controlled Smart Optic Materials (ScN, AlN) with Rare Earth Dopants

    Science.gov (United States)

    Kim, Hyun-Jung; Park, Yeonjoon; King, Glen C.; Choi, Sang H.

    2012-01-01

    The purpose of this investigation is to develop the fundamental materials and fabrication technology for field-controlled spectrally active optics that are essential for industry, NASA, and DOD applications such as: membrane optics, filters for LIDARs, windows for sensors, telescopes, spectroscopes, cameras, flat-panel displays, etc. ScN and AlN thin films were fabricated on c-axis Sapphire (0001) or quartz substrate with the RF and DC magnetron sputtering. The crystal structure of AlN in fcc (rocksalt) and hcp (wurtzite) were controlled. Advanced electrical characterizations were performed, including I-V and Hall Effect Measurement. ScN film has a free carrier density of 5.8 x 10(exp 20)/per cubic centimeter and a conductivity of 1.1 x 10(exp 3) per centimeter. The background ntype conductivity of as-grown ScN has enough free electrons that can readily interact with the photons. The high density of free electrons and relatively low mobility indicate that these films contain a high level of shallow donors as well as deep levels. Also, the UV-Vis spectrum of ScN and AlN thin films with rare earth elements (Er or Ho) were measured at room temperature. Their optical band gaps were estimated to be about 2.33eV and 2.24eV, respectively, which are obviously smaller than that of undoped thin film ScN (2.4eV). The red-shifted absorption onset gives direct evidence for the decrease of band gap (Eg) and the energy broadening of valence band states are attributable to the doping. As the doped elements enter the ScN crystal lattices, the localized band edge states form at the doped sites with a reduction of Eg. Using a variable angle spectroscopic ellipsometer, the decrease in refractive index with applied field is observed with a smaller shift in absorption coefficient.

  10. Model of the Glucose-Insulin-Glucagon Dynamics after Subcutaneous Administration of a Glucagon Rescue Bolus in Healthy Humans

    DEFF Research Database (Denmark)

    Wendt, Sabrina Lyngbye; Møller, Jan Kloppenborg; Haidar, Ahmad

    In healthy individuals, insulin and glucagon work in a complex fashion to maintain blood glucose levels within a narrow range. This regulation is distorted in patients with diabetes. The hepatic glucose response due to an elevated glucagon level depends on the current insulin concentration and thus...... endogenous glucose production (EGP) can not be modelled without knowledge of the concentration of both hormones in plasma. Furthermore, literature suggests an upper limit to EGP irrespective of glucagon levels. We build a simulation model of the glucose-insulin-glucagon dynamics in man including saturation...... effect of EGP. Ten healthy subjects received a 1 mg subcutaneous (SC) glucagon bolus (GlucaGen®). Plasma samples were collected until 300 minutes post dose and analyzed for glucagon, insulin, and glucose concentrations. All observations were used to fit a physiological model of the glucose...

  11. Effects of Preceding Ethanol Intake on Glucose Response to Low-Dose Glucagon in Individuals With Type 1 Diabetes

    DEFF Research Database (Denmark)

    Ranjan, Ajenthen; Nørgaard, Kirsten; Tetzschner, Rikke

    2018-01-01

    OBJECTIVE: This study investigated whether preceding ethanol intake impairs glucose response to low-dose glucagon in individuals with type 1 diabetes. RESEARCH DESIGN AND METHODS: This was a randomized, crossover, placebo-controlled study in 12 insulin pump-treated individuals (median...... ethanol compared with placebo. The second glucagon bolus had similar responses between visits, but PG remained 1.8 ± 0.7 mmol/L lower after ethanol compared with placebo. CONCLUSIONS: The ability of low-dose glucagon to treat mild hypoglycemia persisted with preceding ethanol intake, although it tended...... to be metabolized, and a subcutaneous (s.c.) insulin bolus was given to induce mild hypoglycemia. When plasma glucose (PG) was ≤3.9 mmol/L, 100 µg glucagon was given s.c., followed by another s.c. 100 µg glucagon 2 h later. Primary end point was incremental peak PG induced by the first glucagon bolus. RESULTS...

  12. Martensitic Transformation in a β-Type Mg-Sc Alloy

    Science.gov (United States)

    Ogawa, Yukiko; Ando, Daisuke; Sutou, Yuji; Somekawa, Hidetoshi; Koike, Junichi

    2018-03-01

    Recently, we found that a Mg-Sc alloy with a bcc (β) phase exhibits superelasticity and a shape memory effect at low temperature. In this work, we examined the stress-induced and thermally induced martensitic transformation of the β-type Mg-Sc alloy and investigated the crystal structure of the thermally induced martensite phase based on in situ X-ray diffraction (XRD) measurements. The lattice constants of the martensite phase were calculated to be a = 0.3285 nm, b = 0.5544 nm, and c = 0.5223 nm when we assumed that the martensite phase has an orthorhombic structure (Cmcm). Based on the lattice correspondence between a bcc and an orthorhombic structures such as that in the case of β-Ti shape memory alloys, we estimated the transformation strain of the β Mg-Sc alloy. As a result, the transformation strains along the 001, 011, and 111 directions in the β phase were calculated to be + 5.7, + 8.8, and + 3.3%, respectively.

  13. Martensitic Transformation in a β-Type Mg-Sc Alloy

    Science.gov (United States)

    Ogawa, Yukiko; Ando, Daisuke; Sutou, Yuji; Somekawa, Hidetoshi; Koike, Junichi

    2017-12-01

    Recently, we found that a Mg-Sc alloy with a bcc (β) phase exhibits superelasticity and a shape memory effect at low temperature. In this work, we examined the stress-induced and thermally induced martensitic transformation of the β-type Mg-Sc alloy and investigated the crystal structure of the thermally induced martensite phase based on in situ X-ray diffraction (XRD) measurements. The lattice constants of the martensite phase were calculated to be a = 0.3285 nm, b = 0.5544 nm, and c = 0.5223 nm when we assumed that the martensite phase has an orthorhombic structure (Cmcm). Based on the lattice correspondence between a bcc and an orthorhombic structures such as that in the case of β-Ti shape memory alloys, we estimated the transformation strain of the β Mg-Sc alloy. As a result, the transformation strains along the 001, 011, and 111 directions in the β phase were calculated to be + 5.7, + 8.8, and + 3.3%, respectively.

  14. Development of SC structure modularization in Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Mun, Taeyoup [Korea Hydro and Nuclear Power Co., Ltd., Seoul (Korea, Republic of)

    2008-04-15

    New Focus on NPP are Rising Concerns on Global Warming, Potential energy crisis (geo-political), Improved reliability and safety of nuclear power plant, Advent of Generation 3+ NPP technology and Economical Energy Resource. New NPPs are 6 units in Korea and 23 in Asia being built, 32 units being planned in China by 2020 (150 by 2050), 10 units being planned in US by 2020 and IAEA expects $200 billions on NPP construction next 25 years (up to 30% of total world energy). {open_square} SC(Steel Plate Concrete) structure {center_dot} Steel Plate is used as a Structural Element instead of Reinforcing Bars in RC {center_dot} SC structure consists of Steel Plate with Headed Studs. Connected by Tie-bars - The Primary Purpose of Tie-bars is to Stiffen and Hold Together the Plates during Construction Process - Headed Studs are Welded to the Inside of Steel Plate for composite action {open_square} Benefits of SC Structure {center_dot} Shorten Construction Duration for Re bar, Forming and Scaffolding Works {center_dot} Minimize Site Labors {center_dot} Improve the Construction Quality {center_dot} Enable Construction Sites to be kept Clean {open_square} SC Modularization {center_dot} Fit for Modular Construction for Structural Features {center_dot} Fit for Modular Construction for Structural Features {center_dot} Inattentively Effective for Integrated Modules {center_dot} Pre-fabrication, Pre-assembly and Modularization {open_square} Project Overview {center_dot} Project Name: Development of SC structure for Modularization in NPP {center_dot} Project Type: Electric Power Industry R and D (Ministry of Knowledge Economy) {center_dot} Duration: Sep. 2005 {approx} Aug. 2008 (36 Months) {center_dot} Research Team and Scopes - Project Management: Korea Hydro and Nuclear Power Company (KHNP) - Development of Code and Standards for SC Structure: Korea Society of Steel Construction (KSSC) Korea Electric Power Research Institute (KEPRI) - Development of SC Structural Analysis and Design

  15. Determination of a new structure type in the Sc-Fe-Ge-Sn system

    Energy Technology Data Exchange (ETDEWEB)

    Brgoch, Jakoah [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ran, Sheng [Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Thimmaiah, Srinivasa [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Canfield, Paul C. [Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Miller, Gordon J., E-mail: gmiller@iastate.edu [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States)

    2013-01-05

    Highlights: Black-Right-Pointing-Pointer A new structure type with the composition Sc{sub 4}Fe{sub 5}Ge{sub 6.10(3)}Sn{sub 1.47(2)}. Black-Right-Pointing-Pointer Crystallizes in the space group Immm (No. 71, oI144). Black-Right-Pointing-Pointer Sample obtained using a reactive Sn flux. Black-Right-Pointing-Pointer Electronic structure calculations indicate polar intermetallic bonding network. - Abstract: A new structure type has been discovered in the system Sc-Fe-Ge-Sn by employing Sn as a flux medium. According to single crystal X-ray diffraction, the new structure has a composition of Sc{sub 4}Fe{sub 5}Ge{sub 6.10(3)}Sn{sub 1.47(2)} and crystallizes in the space group Immm (No. 71, oI144) with lattice parameters of a = 5.230(1) A, b = 13.467(3) A, and c = 30.003(6) A. The structure is composed of square anti-prismatic clusters that are condensed into zig-zag chains along the [0 1 0] direction. These chains are further condensed through a split Sn/Ge position, forming a three-dimensional network. Magnetization measurements indicate an antiferromagnetic phase transition near 240 K. Electronic structure calculations identified the most favorable bonding network in this new system. Using crystal orbital Hamilton population (COHP) curves and their integrated values (ICOHP), a polar intermetallic bonding network involving Sc-Ge as well as Fe-Sn and Fe-Ge contacts can be assigned to this new structure type.

  16. Epigenome-wide association study of fasting measures of glucose, insulin, and HOMA-IR in the Genetics of Lipid Lowering Drugs and Diet Network study.

    Science.gov (United States)

    Hidalgo, Bertha; Irvin, M Ryan; Sha, Jin; Zhi, Degui; Aslibekyan, Stella; Absher, Devin; Tiwari, Hemant K; Kabagambe, Edmond K; Ordovas, Jose M; Arnett, Donna K

    2014-02-01

    Known genetic susceptibility loci for type 2 diabetes (T2D) explain only a small proportion of heritable T2D risk. We hypothesize that DNA methylation patterns may contribute to variation in diabetes-related risk factors, and this epigenetic variation across the genome can contribute to the missing heritability in T2D and related metabolic traits. We conducted an epigenome-wide association study for fasting glucose, insulin, and homeostasis model assessment of insulin resistance (HOMA-IR) among 837 nondiabetic participants in the Genetics of Lipid Lowering Drugs and Diet Network study, divided into discovery (N = 544) and replication (N = 293) stages. Cytosine guanine dinucleotide (CpG) methylation at ∼470,000 CpG sites was assayed in CD4(+) T cells using the Illumina Infinium HumanMethylation 450 Beadchip. We fit a mixed model with the methylation status of each CpG as the dependent variable, adjusting for age, sex, study site, and T-cell purity as fixed-effects and family structure as a random-effect. A Bonferroni corrected P value of 1.1 × 10(-7) was considered significant in the discovery stage. Significant associations were tested in the replication stage using identical models. Methylation of a CpG site in ABCG1 on chromosome 21 was significantly associated with insulin (P = 1.83 × 10(-7)) and HOMA-IR (P = 1.60 × 10(-9)). Another site in the same gene was significant for HOMA-IR and of borderline significance for insulin (P = 1.29 × 10(-7) and P = 3.36 × 10(-6), respectively). Associations with the top two signals replicated for insulin and HOMA-IR (P = 5.75 × 10(-3) and P = 3.35 × 10(-2), respectively). Our findings suggest that methylation of a CpG site within ABCG1 is associated with fasting insulin and merits further evaluation as a novel disease risk marker.

  17. Saccharomyces cerevisiae Differential Functionalization of Presumed ScALT1 and ScALT2 Alanine Transaminases Has Been Driven by Diversification of Pyridoxal Phosphate Interactions

    Directory of Open Access Journals (Sweden)

    Erendira Rojas-Ortega

    2018-05-01

    Full Text Available Saccharomyces cerevisiae arose from an interspecies hybridization (allopolyploidiza-tion, followed by Whole Genome Duplication. Diversification analysis of ScAlt1/ScAlt2 indicated that while ScAlt1 is an alanine transaminase, ScAlt2 lost this activity, constituting an example in which one of the members of the gene pair lacks the apparent ancestral physiological role. This paper analyzes structural organization and pyridoxal phosphate (PLP binding properties of ScAlt1 and ScAlt2 indicating functional diversification could have determined loss of ScAlt2 alanine transaminase activity and thus its role in alanine metabolism. It was found that ScAlt1 and ScAlt2 are dimeric enzymes harboring 67% identity and intact conservation of the catalytic residues, with very similar structures. However, tertiary structure analysis indicated that ScAlt2 has a more open conformation than that of ScAlt1 so that under physiological conditions, while PLP interaction with ScAlt1 allows the formation of two tautomeric PLP isomers (enolimine and ketoenamine ScAlt2 preferentially forms the ketoenamine PLP tautomer, indicating a modified polarity of the active sites which affect the interaction of PLP with these proteins, that could result in lack of alanine transaminase activity in ScAlt2. The fact that ScAlt2 forms a catalytically active Schiff base with PLP and its position in an independent clade in “sensu strictu” yeasts suggests this protein has a yet undiscovered physiological function.

  18. Saccharomyces cerevisiae Differential Functionalization of Presumed ScALT1 and ScALT2 Alanine Transaminases Has Been Driven by Diversification of Pyridoxal Phosphate Interactions

    Science.gov (United States)

    Rojas-Ortega, Erendira; Aguirre-López, Beatriz; Reyes-Vivas, Horacio; González-Andrade, Martín; Campero-Basaldúa, Jose C.; Pardo, Juan P.; González, Alicia

    2018-01-01

    Saccharomyces cerevisiae arose from an interspecies hybridization (allopolyploidiza-tion), followed by Whole Genome Duplication. Diversification analysis of ScAlt1/ScAlt2 indicated that while ScAlt1 is an alanine transaminase, ScAlt2 lost this activity, constituting an example in which one of the members of the gene pair lacks the apparent ancestral physiological role. This paper analyzes structural organization and pyridoxal phosphate (PLP) binding properties of ScAlt1 and ScAlt2 indicating functional diversification could have determined loss of ScAlt2 alanine transaminase activity and thus its role in alanine metabolism. It was found that ScAlt1 and ScAlt2 are dimeric enzymes harboring 67% identity and intact conservation of the catalytic residues, with very similar structures. However, tertiary structure analysis indicated that ScAlt2 has a more open conformation than that of ScAlt1 so that under physiological conditions, while PLP interaction with ScAlt1 allows the formation of two tautomeric PLP isomers (enolimine and ketoenamine) ScAlt2 preferentially forms the ketoenamine PLP tautomer, indicating a modified polarity of the active sites which affect the interaction of PLP with these proteins, that could result in lack of alanine transaminase activity in ScAlt2. The fact that ScAlt2 forms a catalytically active Schiff base with PLP and its position in an independent clade in “sensu strictu” yeasts suggests this protein has a yet undiscovered physiological function. PMID:29867852

  19. Ab-initio studies of the Sc adsorption and the ScN thin film formation on the GaN(000-1)-(2 × 2) surface

    International Nuclear Information System (INIS)

    Guerrero-Sánchez, J.; Sánchez-Ochoa, F.; Cocoletzi, Gregorio H.; Rivas-Silva, J.F.; Takeuchi, Noboru

    2013-01-01

    First principles total energy calculations have been performed to investigate the initial stages of the Sc adsorption and ScN thin film formation on the GaN(000-1)-(2 × 2) surface. Studies are done within the periodic density functional theory as implemented in the PWscf code of the Quantum ESPRESSO package. The Sc adsorption at high symmetry sites results in the bridge site as the most stable structure. When a Sc monolayer is deposited above the surface the T4 site results as the most stable geometry. The Sc migration into the first Ga monolayer induces the Ga displaced ad-atom to be adsorbed at the T4-2 site. A ScN bilayer may be obtained under the Ga monolayer. Finally a ScN bilayer may be formed in the wurtzite phase above the surface. The formation energy plots show that in the moderate Ga-rich conditions we obtain the formation of a ScN bilayer under the gallium monolayer. However at N-rich conditions the formation of ScN bilayer above the surface is the most favorable structure. We report the density of states to explain the electronic structure of the most favorable geometries. - Highlights: • Studies of the initial stages in the formation of Sc and ScN structures on GaN • In the adsorption of Sc on the GaN the Br site is the most favorable geometry. • When a Sc replaces a Ga of the first monolayer the displaced Ga occupies a T4-2 site. • For Ga-rich conditions there is formation of ScN under the Ga monolayer. • In N-rich conditions there is formation of ScN in the wurtzite phase

  20. Total and high molecular weight (HMW) adiponectin levels and measures of glucose and lipid metabolism following pioglitazone treatment in a randomized placebo-controlled study in polycystic ovary syndrome

    DEFF Research Database (Denmark)

    Glintborg, Dorte; Frystyk, Jan; Højlund, Kurt

    2008-01-01

    and controls and examined possible mechanisms for increased insulin sensitivity during pioglitazone treatment. STUDY SUBJECTS: Thirty PCOS patients randomized to pioglitazone, 30 mg/day, or placebo for 16 weeks and 14 weight-matched healthy females were studied. DESIGN: Total and HMW adiponectin levels were...... measured, and euglycaemic hyperinsulinaemic clamps and indirect calorimetry were performed. Delta-values denoted changes during pioglitazone treatment (16 weeks--basal). RESULTS: Pretreatment adiponectin levels were decreased in PCOS patients vs. controls (P ...OBJECTIVE: Recent studies suggested that the effect of adiponectin on insulin-stimulated glucose metabolism is mediated primarily by the high molecular weight (HMW) form of adiponectin. In the present study we evaluated total and HMW adiponectin in polycystic ovary syndrome (PCOS) patients...