WorldWideScience

Sample records for satellite-to-satellite doppler tracking

  1. Orbit Determination Using Satellite-to-Satellite Tracking Data

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Satellite-to-Satellite Tracking (SST) data can be used to determine the orbits of spacecraft in two ways. One is combined orbit determination, which combines SST data with ground-based tracking data and exploits the enhanced tracking geometry. The other is the autonomous orbit determination, which uses only SST. The latter only fits some particular circumstances since it suffers the rank defect problem in other circumstances. The proof of this statement is presented. The na ture of the problem is also investigated in order to find an effective solution. Several methods of solution are discussed. The feasibility of the methods is demonstrated by their apphcation to a simulation.

  2. Satellite orbit determination and gravity field recovery from satellite-to-satellite tracking

    Science.gov (United States)

    Wakker, K. F.; Ambrosius, B. A. C.; Leenman, H.

    1989-07-01

    Studies on satellite-to-satellite tracking (SST) with POPSAT (a geodetic satellite concept) and a ERS-class (Earth observation) satellite, a Satellite-to-Satellite Tracking (SST) gravity mission, and precise gravity field determination methods and mission requirements are reported. The first two studies primarily address the application of SST between the high altitude POPSAT and an ERS-class or GRM (Geopotential Research Mission) satellite to the orbit determination of the latter two satellites. Activities focussed on the determination of the tracking coverage of the lower altitude satellite by ground based tracking systems and by POPSAT, orbit determination error analysis and the determination of the surface forces acting on GRM. The third study surveys principles of SST, uncertainties of existing drag models, effects of direct luni-solar attraction and tides on orbit and the gravity gradient observable. Detailed ARISTOTELES (which replaced POPSAT) orbit determination error analyses were performed for various ground based tracking networks.

  3. Geoid Recovery using Geophysical Inverse Theory Applied to Satellite to Satellite Tracking Data

    Science.gov (United States)

    Gaposchkin, E. M.; Frey, H. (Technical Monitor)

    2000-01-01

    This report describes a new method for determination of the geopotential. The analysis is aimed at the GRACE mission. This Satellite-to-Satellite Tracking (SST) mission is viewed as a mapping mission The result will be maps of the geoid. The elements of potential theory, celestial mechanics, and Geophysical Inverse Theory are integrated into a computation architecture, and the results of several simulations presented Centimeter accuracy geoids with 50 to 100 km resolution can be recovered with a 30 to 60 day mission.

  4. Local gravity disturbance estimation from multiple-high-single-low satellite-to-satellite tracking

    Science.gov (United States)

    Jekeli, Christopher

    1989-01-01

    The idea of satellite-to-satellite tracking in the high-low mode has received renewed attention in light of the uncertain future of NASA's proposed low-low mission, Geopotential Research Mission (GRM). The principal disadvantage with a high-low system is the increased time interval required to obtain global coverage since the intersatellite visibility is often obscured by Earth. The U.S. Air Force has begun to investigate high-low satellite-to-satellite tracking between the Global Positioning System (GPS) of satellites (high component) and NASA's Space Transportation System (STS), the shuttle (low component). Because the GPS satellites form, or will form, a constellation enabling continuous three-dimensional tracking of a low-altitude orbiter, there will be no data gaps due to lack of intervisibility. Furthermore, all three components of the gravitation vector are estimable at altitude, a given grid of which gives a stronger estimate of gravity on Earth's surface than a similar grid of line-of-sight gravitation components. The proposed Air Force mission is STAGE (Shuttle-GPS Tracking for Anomalous Gravitation Estimation) and is designed for local gravity field determinations since the shuttle will likely not achieve polar orbits. The motivation for STAGE was the feasibility to obtain reasonable accuracies with absolutely minimal cost. Instead of simulating drag-free orbits, STAGE uses direct measurements of the nongravitational forces obtained by an inertial package onboard the shuttle. The sort of accuracies that would be achievable from STAGE vis-a-vis other satellite tracking missions such as GRM and European Space Agency's POPSAT-GRM are analyzed.

  5. Gravimetric geodesy and sea surface topography studies by means of satellite-to-satellite tracking and satellite altimetry

    Science.gov (United States)

    Siry, J. W.

    1972-01-01

    A satellite-to-satellite tracking experiment is planned between ATS-F and GEOS-C with a range accuracy of 2-meters and a range rate accuracy of 0.035 centimeters per second for a 10-second integration time. This experiment is planned for 1974. It is anticipated that it will improve the spatial resolution of the satellite geoid by half an order of magnitude to about 6 degrees. Longer integration times should also permit a modest increase in the acceleration resolution. Satellite altimeter data will also be obtained by means of GEOS-C. An overall accuracy of 5-meters in altitude is the goal. The altimeter, per se, is expected to have an instrumental precision of about 2 meters, and an additional capability to observe with a precision of about 0.2 meters for limited periods.

  6. Local Recovery of Sub-crustal Stress Due to Mantle Convection from Satellite-to-satellite Tracking Data

    Directory of Open Access Journals (Sweden)

    Šprlák Michal

    2016-08-01

    Full Text Available Two integral transformations between the stress function, differentiation of which gives the meridian and prime vertical components of the sub-crustal stress due to mantle convection, and the satellite-to-satellite tracking (SST data are presented in this article. In the first one, the SST data are the disturbing potential differences between twin-satellites and in the second one the line-of-sight (LOS gravity disturbances. It is shown that the corresponding integral kernels are well-behaving and therefore suitable for inversion and recovery of the stress function from the SST data. Recovery of the stress function and the stress components is also tested in numerical experiments using simulated SST data. Numerical studies over the Himalayas show that inverting the disturbing potential differences leads to a smoother stress function than from inverting LOS gravity disturbances. Application of the presented integral formulae allows for recovery of the stress from the satellite mission GRACE and its planned successor.

  7. De-correlated combination of two low-low Satellite-to-Satellite tracking pairs according to temporal aliasing

    Science.gov (United States)

    Murböck, Michael; Pail, Roland

    2014-05-01

    The monitoring of the temporal changes in the Earth's gravity field is of great scientific and societal importance. Within several days a homogeneous global coverage of gravity observations can be obtained with satellite missions. Temporal aliasing of background model errors into global gravity field models will be one of the largest restrictions in future satellite temporal gravity recovery. The largest errors are due to high-frequent tidal and non-tidal atmospheric and oceanic mass variations. Having a double pair low-low Satellite-to-Satellite tracking (SST) scenario on different inclined orbits reduces temporal aliasing errors significantly. In general temporal aliasing effects for a single (-pair) mission strongly depend on the basic orbital rates (Murböck et al. 2013). These are the rates of the argument of the latitude and of the longitude of the ascending node. This means that the revolution time and the length of one nodal day determine how large the temporal aliasing error effects are for each SH order. The combination of two low-low SST missions based on normal equations requires an adequate weighting of the two components. This weighting shall ensure the full de-correlation of each of the two parts. Therefore it is necessary to take the temporal aliasing errors into account. In this study it is analyzed how this can be done based on the resonance orders of the two orbits. Different levels of approximation are applied to the de-correlation approach. The results of several numerical closed-loop simulations are shown including stochastic modeling of realistic future instrument noise. It is shown that this de-correlation approach is important for maximizing the benefit of a double-pair low-low SST mission for temporal gravity recovery. Murböck M, Pail R, Daras I and Gruber T (2013) Optimal orbits for temporal gravity recovery regarding temporal aliasing. Journal of Geodesy, Springer Berlin Heidelberg, ISSN 0949-7714, DOI 10.1007/s00190-013-0671-y

  8. On gravity from SST, geoid from Seasat, and plate age and fracture zones in the Pacific. [Satellite-to-Satellite Tracking

    Science.gov (United States)

    Marsh, B. D.; Marsh, J. G.; Williamson, R. G.

    1984-01-01

    Data from an additional 50 satellite-to-satellite tracking (SST) passes were combined with earlier measurements of the high degree and order (n, m, 12) gravity in the central Pacific. A composite map was produced which shows good agreement with conventional GEM models. Data from the Seasat altimeter was reduced and found to agree well with both the SST and the GEM fields. The maps are dominated especially in the east, by a pattern of roughly east-west anomalies with a transverse wavelength of about 2000 km. Further comparison with regional bathymetric data shows a remarkably close correlation with plate age. Each anomaly band is framed by those major fracture zones having large offsets. The regular spacing of these fractures seems to account for the fabric in the gravity fields. Other anomalies are accounted for by hot spots. The source of part of these anomalies is in the lithosphere itself. The possible plume size and ascent velocity necessary to supply deep mantle material to the upper mantle without complete thermal equilibration is considered. Previously announced in STAR as N84-11559

  9. Global Geopotential Modelling from Satellite-to-Satellite Tracking,

    Science.gov (United States)

    1981-10-01

    spacecrafts circling the Moon. A simple plot of this information showed strong and roughly circular anomalies over the flatlands, or maria , sug...42 . -t 804. .8 ~ 0 .Ci. . .4 U ~ ~ ~ ~ ~ ,t .8M 080 84 4 4 44 c lt 1....13 o30 -136- - 196 & ISLA , 4O cc cll, II :-. , 0.C19ho =Io 4" go I- - *, 0 L

  10. Reducing Antenna Mechanical Noise in Precision Doppler Tracking

    Science.gov (United States)

    Armstrong, J. W.; Estabrook, F. B.; Asmar, S. W.; Iess, L.; Tortora, P.

    2006-05-01

    Precision Doppler tracking of deep-space probes is central to spacecraft navigation and many radio science investigations. The most sensitive Doppler observations to date have been taken using the NASA/JPL Deep Space Network (DSN) antenna DSS 25, a 34-m-diameter beam-waveguide station especially instrumented with simultaneous X-band (approximately 8.4-GHz) and Ka-band (approximately 32-GHz) links and tropospheric scintillation calibration equipment, tracking the Cassini spacecraft. These Cassini observations achieved Doppler fractional frequency stability (Doppler frequency fluctuation divided by center frequency, Delta f / f_o ) of approximately 3 x 10^-15 at tau = 1000 s integration. In those very-high-sensitivity tracks, the leading disturbance was antenna mechanical noise: time-dependent unmodeled physical motion of the ground antenna's phase center caused by antenna sag as the elevation angle changed, unmodeled subreflector motion, wind loading, bulk motion of the antenna as it rolled over irregularities in the supporting azimuth ring, differential thermal expansion of the structure, etc. This noise has seemed irreducible at reasonable cost, since it is unclear how to build a practical, large, moving, steel structure having mechanical stability significantly better than that of current tracking stations. Here we show how the mechanical noise of a large tracking antenna can effectively be removed when two-way Doppler tracking data from an existing DSN antenna are suitably combined with simultaneous tracking data using an ancillary (smaller and stiffer) antenna. Using our method, the mechanical noise in the final Doppler observable can be reduced, substantially, to that of the stiffer antenna.

  11. Method of target tracking with Doppler blind zone constraint

    Institute of Scientific and Technical Information of China (English)

    Wei Han; Ziyue Tang; Zhenbo Zhu

    2013-01-01

    Doppler blind zone (DBZ) has a bad influence on the airborne early warning radar, although it has good detection per-formance for low altitude targets with pulse Doppler (PD) techno-logy. In target tracking, the blind zone can cause target tracking breakage easily. In order to solve this problem, a paral el parti-cle filter (PF) algorithm based on multi-hypothesis motion models (MHMMs) is proposed. The algorithm produces multiple possible target motion models according to the DBZ constraint. Particles are updated with the constraint in each motion model. Once the first measurement from the target which reappears from DBZ fal s into the particle cloud formed by any model, the measurement-track association succeeds and track breakage is avoided. The simulation results show that on the condition of different DBZ ranges, a high association ratio can be got for targets with different maneuverability levels, which accordingly improves the tracking quality.

  12. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking

    Directory of Open Access Journals (Sweden)

    Armstrong J. W.

    2006-01-01

    Full Text Available This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (~millihertz gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity $2 Delta v/c = Delta u/ u_0$, where $Delta u$ is the Doppler shift and $ u_0$ is the radio link carrier frequency. A gravitational wave having strain amplitude $h$ incident on the earth-spacecraft system causes perturbations of order $h$ in the time series of $Delta u/ u_0$. Unlike other detectors, the ~1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series, some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  13. Coupling Between Doppler Radar Signatures and Tornado Damage Tracks

    Science.gov (United States)

    Jedlovec, Gary J.; Molthan, Andrew L.; Carey, Lawrence; Carcione, Brian; Smith, Matthew; Schultz, Elise V.; Schultz, Christopher; Lafontaine, Frank

    2011-01-01

    On April 27, 2011, the southeastern United States was raked with several episodes of severe weather. Numerous tornadoes caused extensive damage, and tragically, the deaths of over 300 people. In Alabama alone, there were 61 confirmed tornados, 4 of them produced EF5 damage, and several were on the ground an hour or more with continuous damage tracks exceeding 80km. The use of Doppler radars covering the region provided reflectivity and velocity signatures that allowed forecasters to monitors the severe storms from beginning to end issuing hundreds of severe weather warnings throughout the day. Meteorologists from the the NWS performed extensive surveys to assess the intensity, duration, and ground track of tornadoes reported during the event. Survey activities included site visits to the affected locations, analysis of radar and satellite data, aerial surveys, and interviews with eyewitnesses. Satellite data from NASA's MODIS and ASTER instruments played a helpful role in determining the location of tornado damage paths and in the assessment. High resolution multispectral and temporal composites helped forecasters corroborate their damage assessments, determine starting and ending points for tornado touchdowns, and helped to provide forecasters with a better big-picture view of the damage region. The imagery also helped to separate damage from the April 27th tornados from severe weather that occurred earlier that month. In a post analysis of the outbreak, tornado damage path signatures observed in the NASA satellite data have been correlated to "debris ball" signatures in the NWS Doppler radars and a special ARMOR dual-polarization radar operated by the University of Alabama Huntsville during the event. The Doppler radar data indicates a circular enhanced reflectivity signal and rotational couplet in the radial velocity likely associated with the tornado that is spatially correlated with the damage tracks in the observed satellite data. An algorithm to detect and

  14. Radio wave phase scintillation and precision Doppler tracking of spacecraft

    Science.gov (United States)

    Armstrong, J. W.

    Phase scintillation caused by propagation through solar wind, ionospheric, and tropospheric irregularities is a noise process for many spacecraft radio science experiments. In precision Doppler tracking observations, scintillation can be the dominant noise process. Scintillation statistics are necessary for experiment planning and in design of signal processing procedures. Here high-precision tracking data taken with operational spacecraft (Mars Observer, Galileo, and Mars Global Surveyor) and ground systems are used to produce temporal statistics of tropospheric and plasma phase scintillation. The variance of Doppler frequency fluctuations is approximately decomposed into two propagation processes. The first, associated with distributed scattering along the sight line in the solar wind, has a smooth spectrum. The second, associated principally with localized tropospheric scattering for X-band experiments, has a marked autocorrelation peak at the two-way light time between the Earth and the spacecraft (thus a cosine-squared modulation of the fluctuation power spectrum). For X-band data taken in the antisolar hemisphere the average noise levels of this process are in good agreement with average tropospheric noise levels determined independently from water vapor radiometer observations and radio interferometic data. The variance of the process having a smooth spectrum is consistent with plasma noise levels determined independently from dual-frequency observations of the Viking spacecraft made at comparable Sun-Earth-spacecraft angles. The observations reported here are used to refine the propagation noise model for Doppler tracking of deep space probes. In particular, they can be used to predict propagation noise levels for high-precision X- and Ka-band tracking observations (e.g., atmosphere/ionosphere/ring occultations, celestial mechanics experiments, and gravitational wave experiments) to be done using the Cassini spacecraft.

  15. Precise Doppler tracking from the Medicina VLBI station

    Science.gov (United States)

    Ambrosini, R.; Comoretto, G.; Iess, L.; Messeri, A.

    1992-06-01

    The first opposition test of Doppler tracking the Ulysses spacecraft from the Medicina VLBI (Very Long Base Interferometry) station (Italy) proved its capability to perform a systematic search for gravitational waves. In house and JPL (Jet Propulsion Laboratory) data analysis showed that the target Allan variance of 3 x 10(exp -14) at 1000 s, planned for the DSN antennas was also achieved from the station. The main observation campaign during the second opposition phase will last for thirty continuous nights--from mid Feb. to mid Mar. 1992. The main hardware and software features developed for this application, together with some results of the first opposition test, are described.

  16. Advanced spacecraft tracking techniques using the Tracking and Data Relay Satellite System /TDRSS/

    Science.gov (United States)

    Teles, J.; Ayres, C.

    1977-01-01

    The TDRSS will consist initially of two geosynchronous satellites and a common ground station at White Sands, New Mexico. According to current schedules, operations are to begin in November 1980. The overall TDRSS will provide high and low bit-rate telemetry, commands, and satellite-to-satellite tracking services. Each Tracking and Data Relay Satellite (TDRS) will have four antenna systems for NASA use. The common ground station at White Sands will have three 18-meter K-band antennas. The tracking equipment at the ground station is required to meet the following specifications: (1) 0.1-radian root-mean-square (rms) phase noise on nondestruct Doppler measurements; (2) 10-nanosecond rms range noise; (3) 50-nanosecond maximum systematic range error. Attention is given to two-way range and Doppler measurements, the bilateration tracking of TDRS, and an experiment using differenced one-way Doppler measurements.

  17. Predicting Paroxysmal Atrial Fibrillation in Cerebrovascular Ischemia Using Tissue Doppler Imaging and Speckle Tracking Echocardiography

    DEFF Research Database (Denmark)

    Olsen, Flemming Javier; Jørgensen, Peter Godsk; Møgelvang, Rasmus

    2016-01-01

    , tissue Doppler imaging (TDI), and speckle tracking. TDI was performed to acquire myocardial peak velocities during systole/ventricular contraction (global s'), early diastole/ventricular filling (global e'), and late diastole/atrial contraction (global a'). Speckle tracking was performed for myocardial...

  18. Using interacting multiple model particle filter to track airborne targets hidden in blind Doppler

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In airborne tracking, the blind Doppler makes the target undetectable, resulting in tracking difficulties. In this paper,we studied most possible blind-Doppler cases and summed them up into two types: targets' intentional tangential flying to radar and unintentional flying with large tangential speed. We proposed an interacting multiple model (IMM) particle filter which combines a constant velocity model and an acceleration model to handle maneuvering motions. We compared the IMM particle filter with a previous particle filter solution. Simulation results showed that the IMM particle filter outperforms the method in previous works in terms of tracking accuracy and continuity.

  19. A Tracking Filter in Spherical Coordinates Enhanced by De-noising of Converted Doppler Measurements

    Institute of Scientific and Technical Information of China (English)

    ZHOU Gongjian; YU Changjun; CUI Naigang; QUAN Taifan

    2012-01-01

    Tracking problem in spherical coordinates with range rate (Doppler) measurements,which would have errors correlated to the range measurement errors,is investigated in this paper.The converted Doppler measurements,constructed by the product of the Doppler measurements and range measurements,are used to replace the original Doppler measurements.A de-noising method based on an unbiased Kalman filter (KF) is proposed to reduce the converted Doppler measurement errors before updating the target states for the constant velocity (CV) model.The states from the de-noising filter are then combined with the Cartesian states from the converted measurement Kalman filter (CMKF) to produce final state estimates.The nonlinearity of the de-noising filter states are handled by expanding them around the Cartesian states from the CMKF in a Taylor series up to the second order term.In the mean time,the correlation between the two filters caused by the common range measurements is handled by a minimum mean squared error (MMSE) estimation-based method.These result in a new tracking filter,CMDN-EKF2.Monte Carlo simulations demonstrate that the proposed tracking filter can provide efficient and robust performance with a modest computational cost.

  20. Assessment of Regional Myocardial Displacement via Spectral Tissue Doppler Compared with Color Tissue Tracking

    Directory of Open Access Journals (Sweden)

    Zahra Ojaghi-Haghighi

    2008-12-01

    Full Text Available Background: The recent developments in tissue Doppler imaging (TDI now more than ever permit the quantification of the myocardial function. In the current systems, tissue tracking or displacement curves are generated from color tissue Doppler data through the instantaneous temporal integral of velocity-time curves. Methods: The purpose of the present study was to assess regional myocardial displacement via spectral TDI. Maximum myocardial velocities were extracted from spectral pulsed tissue Doppler images using a developed computer program and were integrated throughout the cardiac cycle. Spectral tissue Doppler echocardiography was performed to evaluate longitudinal and radial functions in 20 healthy men, and the calculated end-systolic displacements were subsequently compared with the displacements measured from the same areas via color tissue tracking. Results: According to the Bland-Altman analysis between spectral tissue tracking and color tissue tracking, the significant arithmetic mean was 7.34 mm with SD mean differences of ±2.24 mm in all of the evaluated segments. Despite significant differences (p<0.001, there was a good significant correlation between the two methods (r=0.79, p<0.001. Conclusion: A verification study showed that the proposed approach had the ability to assess regional myocardial displacement using spectral TDI, which can be used in a wider range of equipment than is currently possible.

  1. Assessment studies on the inversion of satellite to satellite electron content to obtain electron density profiles in the ionosphere

    CERN Document Server

    Hochegger, G P

    2000-01-01

    The electron content data, obtained by satellite-to-satellite occultations of radio signals can lead to height profiles of electron density by discrete inversion. Since there is no possibility to verify such profiles by means of other measurements (practically never measurements at the same time and same location) it was necessary to simulate occultation scenarios by means of an ionosphere model to obtain a large number of comparisons sufficient for investigations on a statistical basis. The obtained electron contents were inverted and compared with electron density height profiles, obtained with the same ionospheric model for the occultation point. The differences between these profiles were investigated (difference between the F2-peak maxima, the height of the maxima, the shape of the topside and bottom side ionosphere). Since simulations were done for chosen locations (250 randomly spread on the globe) for every month and every second hour and for two solar activity levels (HSA and LSA), a whole year was '...

  2. Extended Kalman Doppler tracking and model determination for multi-sensor short-range radar

    Science.gov (United States)

    Mittermaier, Thomas J.; Siart, Uwe; Eibert, Thomas F.; Bonerz, Stefan

    2016-09-01

    A tracking solution for collision avoidance in industrial machine tools based on short-range millimeter-wave radar Doppler observations is presented. At the core of the tracking algorithm there is an Extended Kalman Filter (EKF) that provides dynamic estimation and localization in real-time. The underlying sensor platform consists of several homodyne continuous wave (CW) radar modules. Based on In-phase-Quadrature (IQ) processing and down-conversion, they provide only Doppler shift information about the observed target. Localization with Doppler shift estimates is a nonlinear problem that needs to be linearized before the linear KF can be applied. The accuracy of state estimation depends highly on the introduced linearization errors, the initialization and the models that represent the true physics as well as the stochastic properties. The important issue of filter consistency is addressed and an initialization procedure based on data fitting and maximum likelihood estimation is suggested. Models for both, measurement and process noise are developed. Tracking results from typical three-dimensional courses of movement at short distances in front of a multi-sensor radar platform are presented.

  3. Myocardial Strain and Strain Rate Imaging: Comparison between Doppler Derived Strain Imaging and Speckle Tracking Echocardiography

    Directory of Open Access Journals (Sweden)

    Anita Sadeghpour

    2013-05-01

    Full Text Available Regional myocardial function has been traditionally assessed by visual estimation (1. Echocardiographic strain imaging which is known as deformation imaging, has been emerged as a quantitative technique to accurately estimate regional myocardial function and contractility. Currently, strain imaging has been regarded as a research tool in the most echocardiography laboratories. However, in recent years, strain imaging has gain momentum in daily clinical practice (2. The following two techniques have dominated the research arena of echocardiography: (1 Doppler based tissue velocity measurements, frequently referred to tissue Doppler or myocardial Doppler, and (2 speckle tracking on the basis of displacement measurements (3. Over the past two decades, Tissue Doppler Imaging (TDI and Doppler –derived strain (S and strain rate (SR imaging were introduced to quantify regional myocardial function. However, Doppler–derived strain variables faced criticisms, with regard to the angle dependency, noise interference, and substantial intraobserver and interobserver variability. The angle dependency is the major weakness of Doppler based methodology; however, it has the advantage of online measurements of velocities and time intervals with excellent temporal resolution, which is essential for the assessment of ischemia (4. Speckle-tracking echocardiography (STE or Non Doppler 2D strain echocardiography is a relatively new, largely angle-independent technique that analyzes motion by tracking natural acoustic reflections and interference patterns within an ultrasonic window. The image-processing algorithm tracks elements with approximately 20 to 40 pixels containing stable patterns and are described as ‘‘speckles’’ or ‘‘fingerprints’’. The speckles seen in grayscale B-mode (2D images are tracked consecutively frame to frame (5, 6. Assessment of 2D strain by STE is a semiautomatic method that requires definition of the myocardium

  4. Precise radio Doppler and interferometric tracking of spacecraft in service of planetary science

    Science.gov (United States)

    Duev, Dmitry; PRIDE team

    2016-10-01

    The Planetary Radio Interferometry and Doppler Experiments (PRIDE) project is designed as a multi-purpose, multidisciplinary enhancement of the space missions science return by means of Doppler and phase-referenced Very Long Baseline Interferometry (VLBI) tracking of spacecraft. These measurements can be used in a multitude of scientific applications, both fundamental and applied, where an accurate estimate of the spacecraft state vector is essential. In particular, the gravitational field of planetary moons can be sampled with close spacecraft flybys, allowing to probe the moons' interior.In this presentation, we will describe the principles of PRIDE data collection, processing, and analysis. We will present the results of demonstrational observations of a Phobos flyby conducted by ESA's Mars Express spacecraft.

  5. Dynamical effects of General Relativity on the satellite-to-satellite range and range-rate in the GRACE mission

    CERN Document Server

    Iorio, Lorenzo

    2010-01-01

    We numerically investigate the impact of the General Theory of Relativity (GTR) on the satellite-to-satellite range \\rho and range-rate \\dot\\rho of the twin GRACE A/B spacecrafts through their dynamical equations of motion. The present-day accuracies in measuring such observables are \\sigma_\\rho <= 1-10 micron, \\sigma_\\dot\\rho <= 1 micron s^-1. Studies for a follow-on of such a mission points toward a range-rate accuracy of the order of \\sigma_\\dot\\rho = 1 nm s^-1 or better. We also compute the dynamical range and range-rate perturbations caused by the first six zonal harmonic coefficients J_L, L=2,3,4,5,6,7$ of the classical multipolar expansion of the terrestrial gravitational potential in order to evaluate their aliasing impact on the relativistic effects. Conversely, we also quantitatively assessed the possible a-priori \\virg{imprinting} of GTR itself, not solved-for in all the GRACE-based Earth's gravity models produced so far, on the estimated values of the low degree zonals of the geopotential. T...

  6. Atmospheric profiling via satellite to satellite occultations near water and ozone absorption lines for weather and climate

    Science.gov (United States)

    Kursinski, E. R.; Ward, D.; Otarola, A. C.; McGhee, J.; Stovern, M.; Sammler, K.; Reed, H.; Erickson, D.; McCormick, C.; Griggs, E.

    2016-05-01

    Significantly reducing weather and climate prediction uncertainty requires global observations with substantially higher information content than present observations provide. While GPS occultations have provided a major advance, GPS observations of the atmosphere are limited by wavelengths chosen specifically to minimize interaction with the atmosphere. Significantly more information can be obtained via satellite to satellite occultations made at wavelengths chosen specifically to characterize the atmosphere. Here we describe such a system that will probe cm- and mmwavelength water vapor absorption lines called the Active Temperature, Ozone and Moisture Microwave Spectrometer (ATOMMS). Profiling both the speed and absorption of light enables ATOMMS to profile temperature, pressure and humidity simultaneously, which GPS occultations cannot do, as well as profile clouds and turbulence. We summarize the ATOMMS concept and its theoretical performance. We describe field measurements made with a prototype ATOMMS instrument and several important capabilities demonstrated with those ground based measurements including retrieving temporal variations in path-averaged water vapor to 1%, in clear, cloudy and rainy conditions, up to optical depths of 17, remotely sensing turbulence and determining rain rates. We conclude with a vision of a future ATOMMS low Earth orbiting satellite constellation designed to take advantage of synergies between observational needs for weather and climate, ATOMMS unprecedented orbital remote sensing capabilities and recent cubesat technological innovations that enable a constellation of dozens of very small spacecraft to achieve many critical, but as yet unfulfilled, monitoring and forecasting needs.

  7. High Speed A/D DSP Interface for Carrier Doppler Tracking

    Science.gov (United States)

    Baggett, Timothy

    1998-01-01

    As on-board satellite systems continue to increase in ability to perform self diagnostic checks, it will become more important for satellites to initiate ground communications contact. Currently, the NASA Space Network requires users to pre-arranged times for satellite communications links through the Tracking and Data Relay Satellite (TDRS). One of the challenges in implementing an on-demand access protocol into the Space Network, is the fact that a low Earth orbiting (LEO) satellite's communications will be subject to a doppler shift which is outside the capability of the NASA ground station to lock onto. In a prearranged system, the satellite's doppler is known a priori, and the ground station is able to lock onto the satellite's signal. This paper describes the development of a high speed analog to digital interface into a Digital Signal Processor (DSP). This system will be used for identifying the doppler shift of a LEO satellite through the Space Network, and aiding the ground station equipment in locking onto the signal. Although this interface is specific to one application, it can be used as a basis for interfacing other devices with a DSP.

  8. Precision orbit determination for TOPEX/Poseidon using TDRSS Doppler tracking data

    Science.gov (United States)

    Lerch, F. J.; Doll, C. E.; Marshall, J. A.; Luthcke, S. B.; Williamson, R. G.; Klosko, S. M.; McCarthy, J. J.; Eddy, W. F.

    1995-08-01

    Precision orbit determination on the TOPEX/Poseidon (T/P) altimeter satellite is now being routinely achieved with sub-5cm radial and sub-15 cm total positioning accuracy using state-of-the-art modeling with precision tracking provided by a combination of: (a) global Satellite Laser Ranging (SLR) and Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS), or (b) the Global Positioning System (GPS) Constellation which provides pseudo-range and carrier phase observations. The geostationary Tracking and Data Relay Satellite System (TDRSS) satellites are providing the operational tracking and communication support for this mission. The TDRSS Doppler data are of high precision (0.3 mm/s nominal noise levels). Unlike other satellite missions supported operationally by TDRSS, T/P has high quality independent tracking which enables absolute orbit accuracy assessments. In addition, the T/P satellite provides extensive geometry for positioning a satellite at geostationary altitude, and thus the TDRSS-T/P data provides an excellent means for determining the TDRS orbits. Arc lengths of 7 and 10 days with varying degrees of T/P spacecraft attitude complexity are studied. Sub-meter T/P total positioning error is achieved when using the TDRSS range-rate data, with radial orbit errors of 10.6 cm and 15.5 cm RMS for the two arcs studied. Current limitations in the TDRSS precision orbit determination capability include mismodeling of numerous TDRSS satellite-specific dynamic and electronic effects, and in the inadequate treatment of the propagation delay and bending arising from the wet troposphere and ionosphere.

  9. Inductive Magnetic Footpoint Tracking by Combining the Minimum Energy Fit with the Local Correlation Tracking and Doppler Velocity

    Indian Academy of Sciences (India)

    B. Ravindra; D. W. Longcope

    2008-03-01

    Time-dependent magneto-hydrodynamic simulations of active region coronal magnetic field require the underlying photospheric magnetic footpoint velocities. The minimum energy fit (MEF) is a new velocity inversion technique to infer the photospheric magnetic footpoint velocities using a pair of vector magnetograms, introduced by Longcope (2004). The MEF selects the smallest overall flow from several consistent flows by minimizing an energy functional. The inferred horizontal and vertical flow fields by the MEF can be further constrained by incorporating the partial or imperfect velocity information obtained through independent means. This hybrid method is expected to give a velocity close to the true magnetic footpoint velocity. Here, we demonstrate that a combination of the MEF, the local correlation tracking (LCT) and Doppler velocity is capable of inferring the velocity close to the photospheric flow.

  10. Early Mission Orbit Determination Error Analysis Results for Low-Earth Orbiting Missions using TDRSS Differenced One-way Doppler Tracking Data

    Science.gov (United States)

    Marr, Greg C.

    2003-01-01

    Differencing multiple, simultaneous Tracking and Data Relay Satellite System (TDRSS) one-way Doppler passes can yield metric tracking data usable for orbit determination for (low-cost) spacecraft which do not have TDRSS transponders or local oscillators stable enough to allow the one-way TDRSS Doppler tracking data to be used for early mission orbit determination. Orbit determination error analysis results are provided for low Earth orbiting spacecraft for various early mission tracking scenarios.

  11. Prospects of detecting gravitational background radiation by Doppler tracking interplanetary spacecraft

    Energy Technology Data Exchange (ETDEWEB)

    Bertotti, B.; Carr, B.J.

    1980-03-15

    We examine the theoretical and experimental prospects of detecting a low-frequency, continuous, stochastic background of gravitational waves by Doppler tracking interplanetary spacecraft. From a theoretical standpoint, such a background may have been generated by various postgalactic processes or by pregalactic black hole formation; there could also exist a primordial background which goes back to the beginning of the universe. We review the characteristic frequency and density ranges which one might anticipate for these backgrounds. From an experimental standpoint, one's ability to detect a background is limited by the finite length of the record available and by an imperfect knowledge of the spectrum of various sources of noise. The fundamental contribution to the noise comes from the clock which regulates the frequency of the tracking waves. If one uses a hydrogen maser clock, this noise becomes progressively less important with decreasing frequency: one might hope to detect a critical density of background radiation at frequencies below 10/sup -2/ Hz and a background with 10/sup -4/ times the critical density at frequencies below 10/sup -5/ Hz. It is encouraging that some of the sorts of background which we anticipate from theoretical considerations fall within the observable regime. We discuss the extent to which other sources of noise may exceed the clock noise and the degree to which they can be eliminated.

  12. Rotating blade vibration analysis using photogrammetry and tracking laser Doppler vibrometry

    Science.gov (United States)

    Gwashavanhu, Benjamin; Oberholster, Abrie J.; Heyns, P. Stephan

    2016-08-01

    Online structural dynamic analysis of turbomachinery blades is conventionally done using contact techniques such as strain gauges for the collection of data. To transfer the captured data from the sensor to the data logging system, installation of telemetry systems is required. This is usually complicated, time consuming and may introduce electrical noise into the data. In addition, contact techniques are intrusive by definition and can introduce significant local mass loading. This affects the integrity of the captured measurements. Advances in technology now allow for the use of optical non-contact methods to analyse the dynamics of rotating structures. These include photogrammetry and tracking laser Doppler vibrometry (TLDV). Various investigations to establish the integrity of photogrammetry measurements for rotating structures involved a comparison to data captured using accelerometers. Discrepancies that were noticed were attributed to the intrusive nature of the contact measurement technique. As an extended investigation, the presented work focuses on the validation of photogrammetry applied to online turbomachinery blade measurements, using TLDV measurements. Through a frequency based characterisation approach of the dynamics of the two scanning mirrors inside the scanning head of a scanning laser Doppler vibrometer (SLDV), TLDV is employed in developing a system that can be used to achieve a perfect circular scan with a Polytec SLDV, (PSV 300). Photogrammetry out-of-plane displacements of a laser dot focused on a specific point on a rotating blade are compared to displacements captured by the laser scanning system. It is shown that there is good correlation between the two measurement techniques when applied to rotating structures, both in the time and frequency domains. The presence of slight discrepancies between the two techniques after elimination of accelerometer based errors illustrated that the optical system noise floor of photogrammetry does

  13. The Determination of Titan Gravity Field from Doppler Tracking of the Cassini Spacecraft

    Science.gov (United States)

    Iess, L.; Armstrong, J. W.; Aamar, S. W.; DiBenedetto, M.; Graziani, A.; Mackenzie, R.; Racioppa, P.; Rappaport, N.; Tortora, P.

    2007-01-01

    In its tour of the Saturnian system, the spacecraft Cassini is carrying out measurements of the gravity field of Titan, whose knowledge is crucial for constraining the internal structure of the satellite. In the five flybys devoted to gravity science, the spacecraft is tracked in X (8.4 GHz) and Ka band (32.5 GHz) from the antennas of NASA's Deep Space Network. The use of a dual frequency downlink is used to mitigate the effects of interplanetary plasma, the largest noise source affecting Doppler measurements. Variations in the wet path delay are effectively compensated by means of advanced water vapor radiometers placed close to the ground antennas. The first three flybys occurred on February 27, 2006, December 28, 2006, and June 29, 2007. Two additional flybys are planned in July 2008 and May 2010. This paper presents the estimation of the mass and quadrupole field of Titan from the first two flybys, carried out by the Cassini Radio Science Team using a short arc orbit determination. The data from the two flybys are first independently fit using a dynamical model of the spacecraft and the bodies of the Saturnian system, and then combined in a multi-arc solution. Under the assumption that the higher degree harmonics are negligible, the estimated values of the gravity parameters from the combined, multi-arc solution are GM = 8978.1337 +/- 0.0025 km(exp 3) / s(exp 2), J (sub 2) = (2.7221 +/- 0.0185) 10 (exp -5) and C (sub 22) = (1.1159 +/- 0.0040) 10 (exp -5) The excellent agreement (within 1.7 sigma) of the results from the two flybys further increases the confidence in the solution and provides an a posteriori validation of the dynamical model.

  14. [Coronary artery blood flow velocity non-invasively measured using a vessel-tracking pulsed Doppler system].

    Science.gov (United States)

    Tateishi, O; Aizawa, O; Okamura, T; Yoshida, T; Furuhata, H; Seo, Y; Iinuma, K; Shiki, E

    1988-09-01

    A newly-developed noninvasive method was used to measure left coronary blood flow during phantom experiments. Two techniques were used in which: (1) the sample position can always be set in a fluctuating vessel using a wall echo-tracking method with a phase-locked-loop, and (2) the Doppler reference signal was generated separately synchronous with the wall echo signal. These techniques were combined, using a commercially available pulsed Doppler apparatus (SSH-40B: Toshiba). Basic experiments were performed using a blood vessel phantom to verify the validity of these systems. Blood flow velocity in the fluctuating tube could be measured clearly using a vessel-tracking method. The blood flow velocity of the left anterior descending artery was measured in three normal subjects and in seven patients from the third intercostal space along the left sternal border. The velocity pattern was characterized by a crescendo-decrescendo shape in diastole. The peak velocity which appeared in diastole ranged from 19 to 69 cm/sec, with no difference by disease entity. However, in all cases, the blood flow velocity signals were marred by extraneous signals, making it impossible to measure blood flow velocity during systole. Further improvement of the system is mandatory in order to use this flowmeter clinically.

  15. Multistatic Tracking for Continous Active Sonar using Doppler-Bearing Measurements

    Science.gov (United States)

    2013-07-01

    S. Coraluppi, Multistatic active sonar system interoperability, data fusion, and measures of performance, NURC Technical Report NURC -FR-2006-004...of Doppler sensitive and insensitive waveforms, NURC Technical Report SR-427, July 2005. [7] S. Nardone, V. Aidala, Observability Criteria For

  16. Demonstration on the indexes design of gravity satellite orbit parameters in the low-low satellite-to-satellite tracking mode

    Directory of Open Access Journals (Sweden)

    Liu Xiaogang

    2013-02-01

    Full Text Available Combining with the exigent demand of the development of satellite gravimetry system in China, aiming at the determination of technical indexes of gravity satellite orbit parameters, on the basis of the numerical experiments and results analysis, the design indexes of gravity satellite orbit height, inter-satellite range and the orbit inclination are analyzed and calculated, and the issues towards twin gravity satellites such as coherence requirement of the orbit semi-major axes, control requirement of the pitch angle and time interval requirement to keep twin satellites formation in mobility are discussed. Results show that the satellite orbit height is 400 km to 500 km, the inter-satellite range is about 220 km, the satellite orbit inclination is between polar orbit and sun-synchronous orbit, the semi-major axes difference of twin satellites orbit is within ±70. 146 m, the pitch angle of twin satellites is about 0.9 degree, and the time interval to keep twin satellites formation in mobility is 7 days to 15 days.

  17. Comparison of bottom-track to global positioning system referenced discharges measured using an acoustic Doppler current profiler

    Science.gov (United States)

    Wagner, C.R.; Mueller, D.S.

    2011-01-01

    A negative bias in discharge measurements made with an acoustic Doppler current profiler (ADCP) can be caused by the movement of sediment on or near the streambed. The integration of a global positioning system (GPS) to track the movement of the ADCP can be used to avoid the systematic negative bias associated with a moving streambed. More than 500 discharge transects from 63 discharge measurements with GPS data were collected at sites throughout the US, Canada, and New Zealand with no moving bed to compare GPS and bottom-track-referenced discharges. Although the data indicated some statistical bias depending on site conditions and type of GPS data used, these biases were typically about 0.5% or less. An assessment of differential correction sources was limited by a lack of data collected in a range of different correction sources and different GPS receivers at the same sites. Despite this limitation, the data indicate that the use of Wide Area Augmentation System (WAAS) corrected positional data is acceptable for discharge measurements using GGA as the boat-velocity reference. The discharge data based on GPS-referenced boat velocities from the VTG data string, which does not require differential correction, were comparable to the discharges based on GPS-referenced boat velocities from the differentially-corrected GGA data string. Spatial variability of measure discharges referenced to GGA, VTG and bottom-tracking is higher near the channel banks. The spatial variability of VTG-referenced discharges is correlated with the spatial distribution of maximum Horizontal Dilution of Precision (HDOP) values and the spatial variability of GGA-referenced discharges is correlated with proximity to channel banks. ?? 2011 Published by Elsevier B.V.

  18. Multi-Target/Multi-Sensor Tracking using Only Range and Doppler Measurements

    Science.gov (United States)

    2009-04-01

    2009 593 Authorized licensed use limited to: AFRL. Downloaded on July 13, 2009 at 14:21 from IEEE Xplore . Restrictions apply. tracking problems [7—9...from IEEE Xplore . Restrictions apply. mathematical tool for estimating the parameters in mixture models [10—12], and could certainly be used as a...595 Authorized licensed use limited to: AFRL. Downloaded on July 13, 2009 at 14:21 from IEEE Xplore . Restrictions apply. Thus, for each sensor m

  19. The EarthCARE space-borne Doppler 94 GHz radar simulator: correction of multiple scattering, aliasing and NUBF and effects of variable along track integration

    Science.gov (United States)

    Augustynek, T.; Battaglia, A.; Kollias, P.

    2011-12-01

    The primary goal of this work is to address several challenges related to spaceborne Doppler radars like future the EarthCARE mission and recent developments of data simulation, correction and processing. The 94 GHz Cloud Profiling Radar onboard the ESA EarthCARE mission will be the first radar in space with Doppler capability allowing mean Doppler velocity measurements. This will enable more accurate characterization of clouds and precipitation (classification, retrieval accuracy, dynamics). It is the only instrument of this kind planned for the immediate post-CloudSat era and represents an irreplaceable asset in regards to climate change studies. Meeting the scientific accuracy requirements of vertical motions of 1 m/s, with a horizontal resolution of 1 km, is very challenging. The five key factors that control the performance of spaceborne radar will be discussed, such as: contribution of multiple scattering (MS), attenuation, velocity folding, non uniform beam filling (NUBF) and effects of along track integration of the signal. The research utilizes an end-to-end simulator for spaceborne Doppler radars. The simulator uses a Monte Carlo module which accounts for MS and produces ideal Doppler spectra as measured by a spaceborne radar flying over 3D highly resolved scenes produced via WRF Model simulations. The estimates of the Doppler moments (reflectivity, mean Doppler velocity and spectrum width) are achieved via the pulse pair technique. The objective method for identification of MS-contaminated range-bins based purely on the reflectivity-derived variables is described, with most important one, cumulative integrated reflectivity, found to be 41 dBZ_int which serves as the threshold value for identification of radar range gates contaminated by MS. This is further demonstrated in a CloudSat case study with the threshold value for CloudSat is found to be 41.9 dBZ_int. The unfolding procedure of Doppler velocities will be presented. Then we will describe the

  20. Early right ventricular systolic dysfunction in patients with systemic sclerosis without pulmonary hypertension: a Doppler Tissue and Speckle Tracking echocardiography study

    Directory of Open Access Journals (Sweden)

    Baumann Gert

    2010-01-01

    Full Text Available Abstract Background Isovolumetric acceleration (IVA is a novel tissue Doppler parameter for the assessment of systolic function. The aim of this study was to evaluate IVA as an early parameter for the detection of right ventricular (RV systolic dysfunction in patients with systemic sclerosis (SSc without pulmonary hypertension. Methods 22 patients and 22 gender- and age-matched healthy subjects underwent standard echocardiography with tissue Doppler imaging (TDI and speckle tracking strain to assess RV function. Results Tricuspid annular plane systolic excursion (TAPSE (23.2 ± 4.1 mm vs. 26.5 ± 2.9 mm, p 2 vs. 4.1 ± 0.8 m/s2, p Conclusion IVA is a useful tool with high-predictive power to detect early right ventricular systolic impairment in patients with SSc and without pulmonary hypertension.

  1. Venus cloud-tracked and doppler velocimetry winds from CFHT/ESPaDOnS and Venus Express/VIRTIS in April 2014

    Science.gov (United States)

    Machado, Pedro; Widemann, Thomas; Peralta, Javier; Gonçalves, Ruben; Donati, Jean-François; Luz, David

    2017-03-01

    We present new coordinated observations and measurements of the wind amplitude and its variability at Venus cloud-tops based on the two complementary techniques of Ground-based Doppler velocimetry (Widemann et al., 2007, 2008; Machado et al., 2012, 2014) and cloud-tracked winds using ESA Venus Express/ VIRTIS-M imaging at 0.38 μm (Drossart et al., 2007; Sanchez-Lavega et al., 2008; Hueso et al., 2012; Machado et al., 2014). Cloud-tracked winds trace the true atmospheric motion also responsible for the Doppler-Fizeau shift of the solar radiation on the dayside by super-rotating moving cloud-tops with respect to both the Sun and the observer (Machado et al., 2014), and based on this complementarity, we performed a new coordinated campaign in April 2014 combining both Venus Express observations and ground-based Doppler wind measurements on the dayside of Venus' cloud tops at Canada-France-Hawaii telescope at a phase angle Φ =(76 ± 0.3) ∘ . The analysis and results show (1) additional confirmation of the coherence, and complementarity, in the results provided by these techniques, on both spatial and temporal time scales of the two methods; (2) first-time estimation of the meridional component of the wind in another planet using the Doppler velocimetry technique, with evidence of a symmetrical, poleward meridional Hadley flow in both hemispheres of vbarm = 22± 15.5 ms-1; (3) spatial and temporal variability of the zonal flow with latitude and local time, with a significant increase of wind amplitude near the morning terminator previously reported in Feb. 2011 observations.

  2. Ground and space based cloud-top wind velocities using CFHT/ESPaDOnS (Doppler velocimetry) and VEx/VIRTIS (cloud tracking) coordinated measurements

    Science.gov (United States)

    Machado, Pedro; Widemann, Thomas; Peralta, Javier; Gonçalves, Rúben; Donati, Jean-François; Luz, David

    2016-04-01

    We will present wind velocity results based in the measurements of the horizontal wind field at the cloud top level of the atmosphere of Venus, near 70 km altitude. Our aim is contribute to the characterisation of the zonal and meridional wind latitudinal profiles on hour and day-timescales. This will be done by tracking Doppler shift of solar and CO2 lines over the dayside hemisphere in coordination with ESA's Venus Express orbiter. Our observations measured winds at cloud tops at latitudes 60°S-60°N, while Vex/VIRTIS privileged southern latitudes poleward of 45°S. This coordination effort intended to provide a combined monitoring of short-term changes of wind amplitude and directions with extensive spatial coverage. We present results based on inter comparison of ground-based Doppler velocimetry of cloud-top winds and cloud tracking measurements from the Venus Express spacecraft. Doppler wind velocimetry obtained with the 3.60 m Canada-France-Hawaii telescope (CFHT) and the Visible Spectrograph ESPaDOnS in April 2014 consisted of high-resolution spectra of Fraunhofer lines in the visible range (0.37-1.05 μm) to measure the wind velocity using the Doppler shift of solar radiation scattered by cloud top particles in the observer's direction. The complete optical spectrum was collected at a phase angle Φ = (76 ± 0.3)°, at a resolution of about 80000. Both ground-based and Venus Express measurements show considerable day-to-day variability revealing wave propagation and angular momentum transport in latitude which needs to be carefully assessed. ESPaDOnS and the sequential technique of visible Doppler velocimetry has proven a reference technique to measure instantaneous winds. These measurements are necessary to help validating Global Circulation Models (GCMs), to extend the temporal coverage of available datasets. The ground-based observations in the base of this project are critical in their complementarity with Venus Express, which was recently

  3. Acute Effects of an Energy Drink on Myocardial Function Assessed by Conventional Echo-Doppler Analysis and by Speckle Tracking Echocardiography on Young Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Daniele Menci

    2013-01-01

    Full Text Available Purpose. Previous studies have underlined the effects of the energy drinks containing caffeine end taurine on the cardiovascular system. The aim of this study was to determine acute changes on echocardiographic parameters assessed by conventional echo-Doppler analysis and by speckle tracking echocardiography after the consumption of an energy drink in a young healthy population. Methods. measurement of blood pressure, electrocardiographic, and echocardiographic examination were performed on 35 healthy subjects (mean age 25 ± 2 years, 16 men, at baseline and one hour after the consumption of a body surface area indexed amount of an energy drink (168 mL/m2 containing caffeine (0.03% and taurine (0.4%. Results. The analysis of left ventricular function showed a significant increase of mean relative values of MAPSE (+11%; , global longitudinal strain (+10%, , and left ventricular twisting (+22%, in respect to baseline. Also, right ventricular function parameters appeared significantly increased after energy drink consumption, as TAPSE (+15%, , global, and free wall right ventricular longitudinal strain (+8%, ; +5%, , resp.. Conclusion. In conclusion, the consumption of the ED in our population showed a significant increase of right and left ventricular myocardial function, suggesting a possible positive inotropic effect related to the substances contained therein.

  4. Acute effects of an energy drink on myocardial function assessed by conventional echo-Doppler analysis and by speckle tracking echocardiography on young healthy subjects.

    Science.gov (United States)

    Menci, Daniele; Righini, Francesca Maria; Cameli, Matteo; Lisi, Matteo; Benincasa, Susanna; Focardi, Marta; Mondillo, Sergio

    2013-01-01

    Purpose. Previous studies have underlined the effects of the energy drinks containing caffeine end taurine on the cardiovascular system. The aim of this study was to determine acute changes on echocardiographic parameters assessed by conventional echo-Doppler analysis and by speckle tracking echocardiography after the consumption of an energy drink in a young healthy population. Methods. measurement of blood pressure, electrocardiographic, and echocardiographic examination were performed on 35 healthy subjects (mean age 25 ± 2 years, 16 men), at baseline and one hour after the consumption of a body surface area indexed amount of an energy drink (168 mL/m(2)) containing caffeine (0.03%) and taurine (0.4%). Results. The analysis of left ventricular function showed a significant increase of mean relative values of MAPSE (+11%; P < 0.001), global longitudinal strain (+10%, P = 0.004), and left ventricular twisting (+22%, P < 0.0001) in respect to baseline. Also, right ventricular function parameters appeared significantly increased after energy drink consumption, as TAPSE (+15%, P < 0.0001), global, and free wall right ventricular longitudinal strain (+8%, P = 0.001; +5%, P = 0.1, resp.). Conclusion. In conclusion, the consumption of the ED in our population showed a significant increase of right and left ventricular myocardial function, suggesting a possible positive inotropic effect related to the substances contained therein.

  5. A geopotential model from satellite tracking, altimeter, and surface gravity data: GEM-T3

    Science.gov (United States)

    Lerch, F. J.; Nerem, R. S.; Putney, B. H.; Felsentreger, T. L.; Sanchez, B. V.; Marshall, J. A.; Klosko, S. M.; Patel, G. B.; Williamson, R. G.; Chinn, D. S.

    1994-01-01

    An improved model of Earth's gravitational field, Goddard Earth Model T-3 (GEM-T3), has been developed from a combination of satellite tracking, satellite altimeter, and surface gravimetric data. GEM-T3 provides a significant improvement in the modeling of the gravity field at half wavelengths of 400 km and longer. This model, complete to degree and order 50, yields more accurate satellite orbits and an improved geoid representation than previous Goddard Earth Models. GEM-T3 uses altimeter data from GEOS 3 (1975-1976), Seasat (1978) and Geosat (1986-1987). Tracking information used in the solution includes more than 1300 arcs of data encompassing 31 different satellites. The recovery of the long-wavelength components of the solution relies mostly on highly precise satellite laser ranging (SLR) data, but also includes Tracking Network (TRANET) Doppler, optical, and satellite-to-satellite tracking acquired between the ATS 6 and GEOS 3 satellites. The main advances over GEM-T2 (beyond the inclusion of altimeter and surface gravity information which is essential for the resolution of the shorter wavelength geoid) are some improved tracking data analysis approaches and additional SLR data. Although the use of altimeter data has greatly enhanced the modeling of the ocean geoid between 65 deg N and 60 deg S latitudes in GEM-T3, the lack of accurate detailed surface gravimetry leaves poor geoid resolution over many continental regions of great tectonic interest (e.g., Himalayas, Andes). Estimates of polar motion, tracking station coordinates, and long-wavelength ocean tidal terms were also made (accounting for 6330 parameters). GEM-T3 has undergone error calibration using a technique based on subset solutions to produce reliable error estimates. The calibration is based on the condition that the expected mean square deviation of a subset gravity solution from the full set values is predicted by the solutions' error covariances. Data weights are iteratively adjusted until

  6. Doppler Tomography

    CERN Document Server

    Marsh, T R

    2000-01-01

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the a...

  7. Doppler imaging

    Energy Technology Data Exchange (ETDEWEB)

    Piskunov, N [Department of Physics and Astronomy, Uppsala University, Box 515, S-75120 Uppsala (Sweden)], E-mail: piskunov@fysast.uu.se

    2008-12-15

    In this paper, I present a short review of the history and modern status of Doppler imaging techniques, highlighting their dependence on the knowledge of the fundamental stellar parameters, the quality of stellar atmospheric models and the accuracy of spectral synthesis.

  8. Impact of pre-excitation syndrome on left ventricular systolic function and cardiac synchronization assessed by tissue Doppler imaging and speckle tracking techniques

    Directory of Open Access Journals (Sweden)

    Salah Atta

    2014-12-01

    Conclusion: Patients with pre-excitation syndrome may have depressed LV function unrelated to tachyarrhythmia, especially if the AP has a septal location. This dysfunction may be associated with the LV dyssynchronus contraction caused by pre-excitation. The use of TDI and speckle tracking echocardiographic techniques may be associated with an increase in the identification of manifest pre-excitation patients with significant LV dyssynchrony.

  9. The doppler ultrasound. La ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Contreras Cecilia, E.; Lozano Setien, E.; Hernandez Montero, J.; Ganado Diaz, T.; Jorquera Moya, M.; Blasco Pascual, E. (Hospital Universitario San Carlos. Madrid (Spain))

    1994-01-01

    The discovery and development of Doppler ultrasound has had a great influence on Medical practice since it allows the noninvasive study of vascular pathology, both arterial and venous, as well as the flow patterns of the different parenchyma. This article deals with the principles, limitations and interpretation of the Doppler signal, as well as the different Doppler ultrasound systems routinely employed in Medicine.

  10. 多普勒频率变化率快速最大似然估计辅助的高动态载波跟踪环路%Carrier Tracking Loop in High Dynamic Environment Aided by Fast Maximum Likelihood Estimation of Doppler Frequency Rate-of-change

    Institute of Scientific and Technical Information of China (English)

    郇浩; 陶选如; 陶然; 程小康; 董朝; 李鹏飞

    2014-01-01

    To reach a compromise between efficient dynamic performance and high tracking accuracy of carrier tracking loop in high-dynamic circumstance which results in large Doppler frequency and Doppler frequency rate-of-change, a fast maximum likelihood estimation method of Doppler frequency rate-of-change is proposed in this paper, and the estimation value is utilized to aid the carrier tracking loop. First, it is pointed out that the maximum likelihood estimation method of Doppler frequency and Doppler frequency rate-of-change is equivalent to the Fractional Fourier Fransform (FrFT). Second, the estimation method of Doppler frequency rate-of-change, which combines the instant self-correlation and the segmental Discrete Fourier Transform (DFT) is proposed to solve the large two-dimensional search calculation amount of the Doppler frequency and Doppler frequency rate-of-change, and the received coarse estimation value is applied to narrow down the search range. Finally, the estimation value is used in the carrier tracking loop to reduce the dynamic stress and improve the tracking accuracy. Theoretical analysis and computer simulation show that the search calculation amount falls to 5.25 percent of the original amount with Signal to Noise Ratio (SNR)-30 dB, and the Root Mean Sguare Error(RMSE) of frequency tracked is only 8.46 Hz/s, compared with the traditional carrier tracking method the tracking sensitivity can be improved more than 3 dB.%高动态环境下接收信号含有较大的多普勒频率及其变化率,传统载波跟踪方法难以在高动态应力和跟踪精度两方面取得较好折中,针对这一问题该文提出一种多普勒频率变化率快速最大似然估计方法,并利用估计值辅助载波跟踪环路。首先指出了多普勒频率及其变化率的最大似然估计可等效采用分数阶傅里叶变换(FrFT)来实现;其次,针对频率及其变化率2维搜索运算量大的问题,提出一种瞬时自相关与分段离

  11. Value of tissue Doppler-derived Tei index and two-dimensional speckle tracking imaging derived longitudinal strain on predicting outcome of patients with light-chain cardiac amyloidosis.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Herrmann, Sebastian; Cikes, Maja; Ertl, Georg; Weidemann, Frank; Störk, Stefan; Nordbeck, Peter

    2017-06-01

    Prognosis of patients with light-chain cardiac amyloidosis (AL-CA) is poor. Speckle tracking imaging (STI) derived longitudinal deformation parameters and Doppler-derived left ventricular (LV) Tei index are valuable predictors of outcome in patients with AL-CA. We estimated the prognostic utility of Tei index and deformation parameters in 58 comprehensively phenotyped patients with AL-CA after a median follow-up of 365 days (quartiles 121, 365 days). The primary end point was all-cause mortality. 19 (33%) patients died during follow-up. Tei index (0.89 ± 0.29 vs. 0.61 ± 0.16, p < 0.001) and E to global early diastolic strain rate ratio (E/GLSRdias) were higher while global longitudinal systolic strain (GLSsys) was lower in non-survivors than in survivors (all p < 0.05). Tei index, NYHA functional class, GLSsys and E/GLSRdias were independent predictors of all-cause mortality risk, and Tei index ≥0.9 (HR 7.01, 95% CI 2.43-20.21, p < 0.001) was the best predictor of poor outcome. Combining Tei index and GLSsys yielded the best results on predicting death within 1 year (100% with Tei index ≥0.9 and GLSsys ≤13%) or survival (95% with Tei index ≤0.9 and GLSsys ≥13%). We conclude that 1-year mortality risk in AL-CA patients can be reliably predicted using Tei index or deformation parameters, with combined analysis offering best performance.

  12. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...... the detected doppler frequency. It is found that the doppler frequency for this particular setup is independent of the direction of detection. Investigations of the signal-to-noise ratio (SNR) show that the maximum SNR-considering the optical setup-is obtained by measuring the frequency difference between two...

  13. Tendinopathy and Doppler activity

    DEFF Research Database (Denmark)

    Boesen, M I; Koenig, M J; Torp-Pedersen, S

    2006-01-01

    Intratendinous Doppler activity has been interpreted as an equivalent of neovessels in the Achilles tendon and as a sign of tendinosis (AT).......Intratendinous Doppler activity has been interpreted as an equivalent of neovessels in the Achilles tendon and as a sign of tendinosis (AT)....

  14. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue ...

  15. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been......Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  16. 利用卫星跟踪卫星视线加速度确定月球重力场的模拟研究%Simulation Study on the Lunar Gravity Field Determination Using Satellite-to-satellite Tracking Line-of-sight Acceleration

    Institute of Scientific and Technical Information of China (English)

    刘志勇; 李建成; 魏辉; 丰海

    2014-01-01

    月球重力场的研究是实施探月工程的前提和基础,但由于目前探月技术不足及月球特殊的物理环境,现有远月面重力场的精度难以保证探测器远月面登陆,而已在地球重力场研究方面得以成功实施的卫星跟踪卫星(SST)技术为解决这一难题提供了可能.本文通过模拟数据研究卫星跟踪卫星视线加速度确定月球重力场方法的可行性和可靠性,计算GRAIL卫星轨道参数下的月球全球重力异常.结果表明,卫星跟踪卫星视线加速度能较好地展现月球全球重力场的精细结构.

  17. Doppler-cancelled response to VLF gravitational waves

    Science.gov (United States)

    Caporali, A.

    1981-01-01

    The interaction of long periodic gravitational waves with a three link microwave system known as the Doppler Cancelling System is discussed. This system, which was developed for a gravitational redshift experiment, uses one-way and two-way Doppler informatin to construct the beat signal of two reference oscillators moving with respect to each other. The geometric optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational wave space-time. The signature left on the Doppler-cancelled beat by burst and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler Cancelling System and that of a Doppler tracking system which employs two-way, round-trip radio waves. A three-fold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  18. Pulse subtraction Doppler

    Science.gov (United States)

    Mahue, Veronique; Mari, Jean Martial; Eckersley, Robert J.; Caro, Colin G.; Tang, Meng-Xing

    2010-01-01

    Recent advances have demonstrated the feasibility of molecular imaging using targeted microbubbles and ultrasound. One technical challenge is to selectively detect attached bubbles from those freely flowing bubbles and surrounding tissue. Pulse Inversion Doppler is an imaging technique enabling the selective detection of both static and moving ultrasound contrast agents: linear scatterers generate a single band Doppler spectrum, while non-linear scatterers generate a double band spectrum, one being uniquely correlated with the presence of contrast agents and non-linear tissue signals. We demonstrate that similar spectrums, and thus the same discrimination, can be obtained through a Doppler implementation of Pulse Subtraction. This is achieved by reconstructing a virtual echo using the echo generated from a short pulse transmission. Moreover by subtracting from this virtual echo the one generated from a longer pulse transmission, it is possible to fully suppress the echo from linear scatterers, while for non-linear scatterers, a signal will remain, allowing classical agent detection. Simulations of a single moving microbubble and a moving linear scatterer subject to these pulses show that when the virtual echo and the long pulse echo are used to perform pulsed Doppler, the power Doppler spectrum allows separation of linear and non-linear moving scattering. Similar results are obtained on experimental data acquired on a flow containing either microbubble contrast agents or linear blood mimicking fluid. This new Doppler method constitutes an alternative to Pulse Inversion Doppler and preliminary results suggest that similar dual band spectrums could be obtained by the combination of any non-linear detection technique with Doppler demodulation.

  19. Steerable Doppler transducer probes

    Energy Technology Data Exchange (ETDEWEB)

    Fidel, H.F.; Greenwood, D.L.

    1986-07-22

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis.

  20. Doppler cooling a microsphere

    CERN Document Server

    Barker, P F

    2010-01-01

    Doppler cooling the center-of-mass motion of an optically levitated microsphere via the velocity dependent scattering force from narrow whispering gallery mode (WGM) resonances is described. Light that is red detuned from the WGM resonance can be used to damp the center-of-mass motion in a process analogous to the Doppler cooling of atoms. Leakage of photons out of the microsphere when the incident field is near resonant with the narrow WGM resonance acts to damp the motion of the sphere. The scattering force is not limited by saturation, but can be controlled by the incident power. Cooling times on the order of seconds are calculated for a 20 micron diameter silica microsphere trapped within optical tweezers, with a Doppler temperature limit in the microKelvin regime.

  1. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  2. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  3. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  4. The Doppler Pendulum Experiment

    Science.gov (United States)

    Lee, C. K.; Wong, H. K.

    2011-01-01

    An experiment to verify the Doppler effect of sound waves is described. An ultrasonic source is mounted at the end of a simple pendulum. As the pendulum swings, the rapid change of frequency can be recorded by a stationary receiver using a simple frequency-to-voltage converter. The experimental results are in close agreement with the Doppler…

  5. Reducing antenna mechanical noise in precision spacecraft tracking

    Science.gov (United States)

    Armstrong, J. W.; Estabrook, F. B.; Asmar, S. W.; Iess, L.; Tortora, P.

    2008-06-01

    Doppler tracking of deep space probes is central to spacecraft navigation and many radio science investigations. The most sensitive Doppler observations to date were taken using the NASA/JPL Deep Space Network antenna DSS 25 (a 34 m diameter beam-waveguide station instrumented with simultaneous X- and Ka-band uplink and tropospheric scintillation calibration equipment) tracking the Cassini spacecraft. Those observations achieved Doppler fractional frequency stability (Doppler frequency fluctuation divided by center frequency, Δf/fo) ≈ 3 X 10-15 at 1000 s integration time. The leading noise in these very-high-sensitivity tracks was time-dependent unmodeled motion of the ground antenna's phase center (caused, e.g., by antenna sag as elevation angle changes, unmodeled subreflector motion, wind loading, bulk motion of the antenna as it rolled over irregularities in its azimuth ring, etc.). This antenna mechanical noise has seemed irreducible since it is not clear how to build a large, moving, steel structure with intrinsic mechanical stability better than that of current tracking stations. Here we show how intrinsic mechanical noise of a large tracking antenna can be suppressed when two-way Doppler tracking data and receive-only Doppler data from a stiffer antenna are combined with suitable delays. Using this time delay correction procedure, the mechanical noise in the final Doppler observable can be reduced to that of the stiffer antenna. We demonstrate proof-of-concept experimentally and briefly discuss some practical considerations.

  6. Laser Doppler flowmetry imaging

    Science.gov (United States)

    Nilsson, Gert E.; Wardell, Karin

    1994-02-01

    A laser Doppler perfusion imager has been developed that makes possible mapping of tissue blood flow over surfaces with extensions up to about 12 cm X 12 cm. The He-Ne laser beam scans the tissue under study throughout 4096 measurement sites. A fraction of the backscattered and Doppler broadened light is detected by a photo diode positioned about 20 cm above the tissue surface. After processing, a signal that scales linearly with perfusion is stored in a computer and a color coded image of the spatial tissue perfusion is shown on a monitor. A full format scan is completed in about 4.5 minutes. Algorithms for calculating perfusion profiles and averages as well as substraction of one image from another, form an integral part of the system data analysis software. The perfusion images can also be exported to other software packages for further processing and analysis.

  7. Scanning laser Doppler vibrometry

    OpenAIRE

    2016-01-01

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from Polytec Inc. – was acquired and put to operation in October 2014, paid by a sub-donation of DKK 1,5 mill. of the total VILLUM CASMaT grant. Opening possibilities of measuring complicated vibration shapes...

  8. Holographic laser Doppler ophthalmoscopy

    CERN Document Server

    Simonutti, Manuel; Sahel, J A; Gross, Michel; Samson, Benjamin; Magnain, Caroline; Atlan, Michael; 10.1364/OL.35.001941

    2010-01-01

    We report laser Doppler ophthalmoscopic fundus imaging in the rat eye with near-IR heterodyne holography. Sequential sampling of the beat of the reflected radiation against a frequency-shifted optical local oscillator is made onto an array detector. Wide-field maps of fluctuation spectra in the 10 Hz to 25 kHz band exhibit angiographic contrasts in the retinal vascular tree without requirement of an exogenous marker.

  9. Laser double Doppler flowmeter

    Science.gov (United States)

    Poffo, L.; Goujon, J.-M.; Le Page, R.; Lemaitre, J.; Guendouz, M.; Lorrain, N.; Bosc, D.

    2014-05-01

    The Laser Doppler flowmetry (LDF) is a non-invasive method for estimating the tissular blood flow and speed at a microscopic scale (microcirculation). It is used for medical research as well as for the diagnosis of diseases related to circulatory system tissues and organs including the issues of microvascular flow (perfusion). It is based on the Doppler effect, created by the interaction between the laser light and tissues. LDF measures the mean blood flow in a volume formed by the single laser beam, that penetrate into the skin. The size of this measurement volume is crucial and depends on skin absorption, and is not directly reachable. Therefore, current developments of the LDF are focused on the use of always more complex and sophisticated signal processing methods. On the other hand, laser Double Doppler Flowmeter (FL2D) proposes to use two laser beams to generate the measurement volume. This volume would be perfectly stable and localized at the intersection of the two laser beams. With FL2D we will be able to determine the absolute blood flow of a specific artery. One aimed application would be to help clinical physicians in health care units.

  10. Improved cardiac motion detection from ultrasound images using TDIOF: a combined B-mode/ tissue Doppler approach

    Science.gov (United States)

    Tavakoli, Vahid; Stoddard, Marcus F.; Amini, Amir A.

    2013-03-01

    Quantitative motion analysis of echocardiographic images helps clinicians with the diagnosis and therapy of patients suffering from cardiac disease. Quantitative analysis is usually based on TDI (Tissue Doppler Imaging) or speckle tracking. These methods are based on two independent techniques - the Doppler Effect and image registration, respectively. In order to increase the accuracy of the speckle tracking technique and cope with the angle dependency of TDI, herein, a combined approach dubbed TDIOF (Tissue Doppler Imaging Optical Flow) is proposed. TDIOF is formulated based on the combination of B-mode and Doppler energy terms in an optical flow framework and minimized using algebraic equations. In this paper, we report on validations with simulated, physical cardiac phantom, and in-vivo patient data. It is shown that the additional Doppler term is able to increase the accuracy of speckle tracking, the basis for several commercially available echocardiography analysis techniques.

  11. Time-variable gravity fields from satellite tracking

    Science.gov (United States)

    Bettadpur, Srinivas; Cheng, Minkang; Ries, John

    2014-05-01

    At the University of Texas Center for Space Research (CSR), we routinely deliver time-series of Earth's gravity field variations, some of it spanning more than two decades. These time-series are derived - in a consistent manner - from satellite laser ranging (SLR) data, from low-Earth orbiters tracked using GPS, and from low-low satellite to satellite tracking data from GRACE. In this paper, we review the information content in the gravity field time-series derived from each of these methods. We provide a comparison of the time-series at the decadal and annual time-scales, and identify the spatial modes of variability that are well or poorly estimated by each of the observing systems. The results have important bearing on the prospects of extending GRACE time-variable gravity time-series in the event of gaps between dedicated gravity missions, and for extending the time-series into the past. Support for this research from joint NASA/DLR GRACE mission, the NASA MEASURs program, and the NASA ROSES/GRACE Science Team is gratefully acknowledged.

  12. A Cramer Rao analysis on receiver placement in a FM band commensal radar system based on doppler only measurements

    CSIR Research Space (South Africa)

    Maasdorp, FDV

    2014-10-01

    Full Text Available This paper investigates the theoretical placement of receivers in an Commensal Radar (CR), Doppler only tracking system with a single transmitter multiple receiver configuration. Theory, based on the Fisher Information matrix (FIM), is developed...

  13. Advanced W-Band Gallium Nitride Monolithic Microwave Integrated Circuits (MMICs) for Cloud Doppler Radar Supporting ACE Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop W-band Gallium Nitride (GaN) MMICs to enable the advanced cross-track scanning, dual-frequency Doppler cloud radar concept in support of the...

  14. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  15. ANL Doppler flowmeter

    Science.gov (United States)

    Karplus, H. B.; Raptis, A. C.; Lee, S.; Simpson, T.

    1985-10-01

    A flowmeter has been developed for measuring flow velocity in hot slurries. The flowmeter works on an ultrasonic Doppler principle in which ultrasound is injected into the flowing fluid through the solid pipe wall. Isolating waveguides separate the hot pipe from conventional ultrasonic transducers. Special clamp-on high-temperature transducers also can be adapted to work well in this application. Typical flows in pilot plants were found to be laminar, giving rise to broad-band Doppler spectra. A special circuit based on a servomechanism sensor was devised to determine the frequency average of such a broad spectrum. The device was tested at different pilot plants. Slurries with particulates greater than 70 microns (0.003 in.) yielded good signals, but slurries with extremely fine particulates were unpredictable. Small bubbles can replace the coarse particles to provide a good signal if there are not too many. Successful operation with very fine particulate slurries may have been enhanced by the presence of microbubbles.

  16. Laser Doppler Imaging of Microflow

    CERN Document Server

    Gross, Michel; Leng, Jacques

    2013-01-01

    We report a pilot study with a wide-field laser Doppler detection scheme used to perform laser Doppler anemometry and imaging of particle seeded microflow. The optical field carrying the local scatterers (particles) dynamic state, as a consequence of momentum transfer at each scattering event, is analyzed in the temporal frequencies domain. The setup is based on heterodyne digital holography, which is used to map the scattered field in the object plane at a tunable frequency with a multipixel detector. We show that wide-field heterodyne laser Doppler imaging can be used for quantitative microflow diagnosis; in the presented study, maps of the first-order moment of the Doppler frequency shift are used as a quantitative and directional estimator of the Doppler signature of particles velocity.

  17. Research on laser Doppler velocimeter for vehicle self-contained inertial navigation system

    Science.gov (United States)

    Jian, Zhou; Xingwu, Long

    2010-04-01

    An idea of using laser Doppler velocimeter (LDV) to measure the velocity for the vehicle inertial navigation system was put forward. The principle of measuring its own velocity with laser Doppler technique was elaborated and reference-beam LDV was designed. Then Doppler signal was processed by tracking filter, frequency spectrum refinement and frequency spectrum correction algorithm. The result of theory and experiment showed that the reference-beam LDV solved the problem that dual-beam LDV cannot be used for measuring when the system was out of focus. Doppler signal was tracked so that signal-to-noise ratio was improved, and the accuracy of the system was enhanced by the technology of frequency spectrum refinement and correction. The measurement mean error was less than 1.5% in velocity range of 0-30 m/s.

  18. Clutter attenuation using the Doppler effect in standoff electromagnetic quantum sensing

    Science.gov (United States)

    Lanzagorta, Marco; Jitrik, Oliverio; Uhlmann, Jeffrey; Venegas, Salvador

    2016-05-01

    In the context of traditional radar systems, the Doppler effect is crucial to detect and track moving targets in the presence of clutter. In the quantum radar context, however, most theoretical performance analyses to date have assumed static targets. In this paper we consider the Doppler effect at the single photon level. In particular, we describe how the Doppler effect produced by clutter and moving targets modifies the quantum distinguishability and the quantum radar error detection probability equations. Furthermore, we show that Doppler-based delayline cancelers can reduce the effects of clutter in the context of quantum radar, but only in the low-brightness regime. Thus, quantum radar may prove to be an important technology if the electronic battlefield requires stealthy tracking and detection of moving targets in the presence of clutter.

  19. Response of a Doppler canceling system to plane gravitational waves

    Science.gov (United States)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for a gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-cancelled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  20. Micro-Doppler Ambiguity Resolution Based on Short-Time Compressed Sensing

    Directory of Open Access Journals (Sweden)

    Jing-bo Zhuang

    2015-01-01

    Full Text Available When using a long range radar (LRR to track a target with micromotion, the micro-Doppler embodied in the radar echoes may suffer from ambiguity problem. In this paper, we propose a novel method based on compressed sensing (CS to solve micro-Doppler ambiguity. According to the RIP requirement, a sparse probing pulse train with its transmitting time random is designed. After matched filtering, the slow-time echo signals of the micromotion target can be viewed as randomly sparse sampling of Doppler spectrum. Select several successive pulses to form a short-time window and the CS sensing matrix can be built according to the time stamps of these pulses. Then performing Orthogonal Matching Pursuit (OMP, the unambiguous micro-Doppler spectrum can be obtained. The proposed algorithm is verified using the echo signals generated according to the theoretical model and the signals with micro-Doppler signature produced using the commercial electromagnetic simulation software FEKO.

  1. Modification of the Doppler effect due to the helicity-rotation coupling

    Energy Technology Data Exchange (ETDEWEB)

    Mashhoon, Bahram

    2002-12-30

    The helicity-rotation coupling and its current empirical basis are examined. The modification of the Doppler effect due to the coupling of photon spin with the rotation of the observer is considered in detail in connection with its applications in the Doppler tracking of spacecraft. Further implications of this coupling and the possibility of searching for it in the intensity response of a rotating detector are briefly discussed.

  2. Doppler characteristics of sea clutter.

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, Ann Marie; Doerry, Armin Walter

    2010-06-01

    Doppler radars can distinguish targets from clutter if the target's velocity along the radar line of sight is beyond that of the clutter. Some targets of interest may have a Doppler shift similar to that of clutter. The nature of sea clutter is different in the clutter and exo-clutter regions. This behavior requires special consideration regarding where a radar can expect to find sea-clutter returns in Doppler space and what detection algorithms are most appropriate to help mitigate false alarms and increase probability of detection of a target. This paper studies the existing state-of-the-art in the understanding of Doppler characteristics of sea clutter and scattering from the ocean to better understand the design and performance choices of a radar in differentiating targets from clutter under prevailing sea conditions.

  3. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  4. Novel instantaneous laser Doppler velocimeter.

    Science.gov (United States)

    Avidor, J M

    1974-02-01

    A laser Doppler velocimeter capable of directly measuring instantaneous velocities is described. The new LDV uses a novel detection technique based on the utilization of a static slightly defocused spherical Fabry-Perot interferometer used in conjunction with a special mask for the detection of instantaneous Doppler frequency shifts. The essential characteristics of this LDV are discussed, and such a system recently developed is described. Results of turbulent flow measurements show good agreement with data obtained using hot wire anemometry.

  5. UWB micro-doppler radar for human gait analysis using joint range-time-frequency representation

    Science.gov (United States)

    Wang, Yazhou; Fathy, Aly E.

    2013-05-01

    In this paper, we present a novel, standalone ultra wideband (UWB) micro-Doppler radar sensor that goes beyond simple range or micro-Doppler detection to combined range-time-Doppler frequency analysis. Moreover, it can monitor more than one human object in both line-of-sight (LOS) and through wall scenarios, thus have full human objects tracking capabilities. The unique radar design is based on narrow pulse transceiver, high speed data acquisition module, and wideband antenna array. For advanced radar post-data processing, joint range-time-frequency representation has been performed. Characteristics of human walking activity have been analyzed using the radar sensor by precisely tracking the radar object and acquiring range-time-Doppler information simultaneously. The UWB micro-Doppler radar prototype is capable of detecting Doppler frequency range from -180 Hz to +180 Hz, which allows a maximum target velocity of 9 m/s. The developed radar sensor can also be extended for many other applications, such as respiration and heartbeat detection of trapped survivors under building debris.

  6. Planetary Doppler Imaging

    Science.gov (United States)

    Murphy, N.; Jefferies, S.; Hart, M.; Hubbard, W. B.; Showman, A. P.; Hernandez, G.; Rudd, L.

    2014-12-01

    Determining the internal structure of the solar system's gas and ice giant planets is key to understanding their formation and evolution (Hubbard et al., 1999, 2002, Guillot 2005), and in turn the formation and evolution of the solar system. While internal structure can be constrained theoretically, measurements of internal density distributions are needed to uncover the details of the deep interior where significant ambiguities exist. To date the interiors of giant planets have been probed by measuring gravitational moments using spacecraft passing close to, or in orbit around the planet. Gravity measurements are effective in determining structure in the outer envelope of a planet, and also probing dynamics (e.g. the Cassini and Juno missions), but are less effective in probing deep structure or the presence of discrete boundaries. A promising technique for overcoming this limitation is planetary seismology (analogous to helioseismology in the solar case), postulated by Vorontsov, 1976. Using trapped pressure waves to probe giant planet interiors allows insight into the density and temperature distribution (via the sound speed) down to the planetary core, and is also sensitive to sharp boundaries, for example at the molecular to metallic hydrogen transition or at the core-envelope interface. Detecting such boundaries is not only important in understanding the overall structure of the planet, but also has implications for our understanding of the basic properties of matter at extreme pressures. Recent Doppler measurements of Jupiter by Gaulme et al (2011) claimed a promising detection of trapped oscillations, while Hedman and Nicholson (2013) have shown that trapped waves in Saturn cause detectable perturbations in Saturn's C ring. Both these papers have fueled interest in using seismology as a tool for studying the solar system's giant planets. To fully exploit planetary seismology as a tool for understanding giant planet structure, measurements need to be made

  7. General principles of carotid Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Whal [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    Carotid Doppler ultrasonography is a popular tool for evaluating atherosclerosis of the carotid artery. Its two-dimensional gray scale can be used for measuring the intima-media thickness, which is very good biomarker for atherosclerosis and can aid in plaque characterization. The plaque morphology is related to the risk of stroke. The ulceration of plaque is also known as one of the strong predictors of future embolic event risk. Color Doppler ultrasonography and pulse Doppler ultrasonography have been used for detecting carotid artery stenosis. Doppler ultrasonography has unique physical properties. The operator should be familiar with the physics and other parameters of Doppler ultrasonography to perform optimal Doppler ultrasonography studies.

  8. Doppler peaks from active perturbations

    CERN Document Server

    Magueijo, J; Coulson, D; Ferreira, P; Magueijo, Joao; Albrecht, Andreas; Coulson, David; Ferreira, Pedro

    1995-01-01

    We examine how the qualitative structure of the Doppler peaks in the angular power spectrum of the cosmic microwave anisotropy depends on the fundamental nature of the perturbations which produced them. The formalism of Hu and Sugiyama is extended to treat models with cosmic defects. We discuss how perturbations can be ``active'' or ``passive'' and ``incoherent'' or ``coherent'', and show how causality and scale invariance play rather different roles in these various cases. We find that the existence of secondary Doppler peaks and the rough placing of the primary peak unambiguously reflect these basic properties.

  9. Inverse Doppler Effects in Flute

    CERN Document Server

    Zhao, Xiao P; Liu, Song; Shen, Fang L; Li, Lin L; Luo, Chun R

    2015-01-01

    Here we report the observation of the inverse Doppler effects in a flute. It is experimentally verified that, when there is a relative movement between the source and the observer, the inverse Doppler effect could be detected for all seven pitches of a musical scale produced by a flute. Higher tone is associated with a greater shift in frequency. The effect of the inverse frequency shift may provide new insights into why the flute, with its euphonious tone, has been popular for thousands of years in Asia and Europe.

  10. A detection method of laser doppler signal based on topo-logical contravariance

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yu-cun; LIU Hai-bin

    2009-01-01

    To detect the laser doppler signal, the unknown signal is tracked by the known signal using the concept of topological contravarisnce. The unknown topological space U and known space Mare founded, and then the unknown signal's trans-formation is tracked dynamically according to this mapping relationship between the two spaces. The system equation is obtained by gradient-descent method, and the conditions of stability are given by Poincare mapping. The proposed method is applied to measure the in-plane displacement signal of the solid 50 m away using laser doppler, signal The result proves that the method can detect laser doppler, signal accurately, its relative error is less than 0.7%.

  11. The Martian rotation from Doppler measurements: Simulations of future radioscience experiments

    Science.gov (United States)

    Péters, Marie-Julie; Yseboodt, Marie; Dehant, Véronique; Le Maistre, Sebastien; Marty, Jean-Charles

    2016-10-01

    The radioscience experiment onboard the future InSight and ExoMars missions consists in two-way Doppler shift measurement from a X-band radio link between a lander on Mars and the ground stations on Earth. The Doppler effect on the radio signal is related to the revolution of the planets around the Sun and to the variations of the orientation and the rotation of Mars. The variations of the orientation of the rotation axis are the precession and nutations, related to the deep interior of Mars and the variations of the rotation rate are the length-of-day variation, related to the dynamic of the atmosphere.We perform numerical simulations of the Doppler measurements in order to quantify the precision that can be achieved on the determination of the Mars rotation and orientation parameters (MOP). For this purpose, we use the GINS (Géodésie par Intégrations Numériques Simultanées) software developed by the CNES and further adapted at the Royal Observatory of Belgium for planetary geodesy applications. This software enables to simulate the relative motion of the lander at the surface of Mars relative to the ground stations and to compute the MOP signature on the Doppler shift. The signature is the difference between the Doppler observable estimated taking into account a MOP and the Doppler estimated without this parameter.The objective is to build a strategy to be applied to future data processing in order to improve our estimation of the MOP. We study the effect of the elevation of the Earth in the sky of the lander, of the tracking duration and number of pass per week, of the tracking time, of the lander position and of Doppler geometry on the signatures. Indeed, due to the geometry, the Doppler data are highly sensitive to the position variations along the line of sight.

  12. Doppler tomography in fusion plasmas and astrophysics

    CERN Document Server

    Salewski, Mirko; Heidbrink, Bill; Jacobsen, Asger Schou; Korsholm, Soren Bang; Leipold, Frank; Madsen, Jens; Moseev, Dmitry; Nielsen, Stefan Kragh; Rasmussen, Jesper; Stagner, Luke; Steeghs, Danny; Stejner, Morten; Tardini, Giovani; Weiland, Markus

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion D-alpha (FIDA) spectroscopy measurements in magnetically confined plasma, the D-alpha-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright spots, spiral structures, and flow patterns. Fusion plasma Doppler tomography has lead to an image of the fast-ion velocity distribution function in the tokamak ASDEX Upgrade. This image matched numerical simulations very well. Here we discuss achievements of the Doppler tomography approach, its promise and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography, and what ...

  13. Doppler Ultrasound: What Is It Used for?

    Science.gov (United States)

    ... in your neck (carotid artery stenosis) A Doppler ultrasound can estimate how fast blood flows by measuring the rate of change in its pitch (frequency). During a Doppler ultrasound, a technician trained in ultrasound imaging (sonographer) presses ...

  14. Phase fluctuation spectra: New radio science information to become available in the DSN tracking system Mark III-77

    Science.gov (United States)

    Berman, A. L.

    1977-01-01

    An algorithm was developed for the continuous and automatic computation of Doppler noise concurrently at four sample rate intervals, evenly spanning three orders of magnitude. Average temporal Doppler phase fluctuation spectra will be routinely available in the DSN tracking system Mark III-77 and require little additional processing. The basic (noise) data will be extracted from the archival tracking data file (ATDF) of the tracking data management system.

  15. On-Orbit Ephemeris Determination with Radio Doppler Validation

    Energy Technology Data Exchange (ETDEWEB)

    Dallmann, Nicholas [Los Alamos National Laboratory; Proicou, Michael Chris [Los Alamos National Laboratory; Seitz, Daniel Nathan [Los Alamos National Laboratory; Warniment, Adam [Los Alamos National Laboratory

    2016-02-09

    Multiple CubeSats are often released from the same host spacecraft into virtually the same orbit at nearly the same time. A satellite team needs the ability to identify and track its own satellites as soon as possible. However, this can be a difficult and confusing task with a large number of satellites. Los Alamos National Laboratory encountered this issue during a launch of LANL-designed CubeSats that were released with more than 20 other objects. A simple radio Doppler method used shortly after launch by the Los Alamos team to select its satellites of interest from the list of available tracked ephemerides is described. This method can also be used for automated real time ephemeris validation. For future efforts, each LANL-designed CubeSat will automatically perform orbit determination from the position, velocity, and covariance estimates provided by an added on-board GPS receiver. This self-determined ephemeris will be automatically downlinked by ground stations for mission planning, antenna tracking, Doppler-pre-correction, etc. A simple algorithm based on established theory and well suited for embedded on-board processing is presented. The trades examined in selecting the algorithm components and data formats are briefly discussed, as is the expected performance.

  16. Velocity-aligned Doppler spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z.; Koplitz, B.; Wittig, C.

    1989-03-01

    The technique of velocity-aligned Doppler spectrosocopy (VADS) is presented and discussed. For photolysis/probe experiments with pulsed initiation, VADS can yield Doppler profiles for nascent photofragments that allow detailed center-of-mass (c.m.) kinetic energy distributions to be extracted. When compared with traditional forms of Doppler spectroscopy, the improvement in kinetic energy resolution is dramatic. Changes in the measured profiles are a consequence of spatial discrimination (i.e., focused and overlapping photolysis and probe beams) and delayed observation. These factors result in the selective detection of species whose velocities are aligned with the wave vector of the probe radiation k/sub pr/, thus revealing the speed distribution along k/sub pr/ rather than the distribution of nascent velocity components projected upon this direction. Mathematical details of the procedure used to model VADS are given, and experimental illustrations for HI, H/sub 2/S, and NH/sub 3/ photodissociation are presented. In these examples, pulsed photodissociation produces H atoms that are detected by sequential two-photon, two-frequency ionization via Lyman-..cap alpha.. with a pulsed laser (121.6+364.7 nm), and measuring the Lyman-..cap alpha.. Doppler profile as a function of probe delay reveals both internal and c.m. kinetic energy distributions for the photofragments. Strengths and weaknesses of VADS as a tool for investigating photofragmentation phenomena are also discussed.

  17. Speckles in laser doppler perfusion imaging

    NARCIS (Netherlands)

    Rajan, Vinayakrishnan

    2007-01-01

    Laser Doppler Flowmetry (LDF) is a noninvasive diagnostic method to measure blood flow in tissue [1]. The technique is based on measuring the Doppler shift induced by moving red blood cells to the illuminating coherent light. A laser Doppler instrument often gives output signals related to the flux,

  18. Micro-Doppler Analysis of Small UAVs

    NARCIS (Netherlands)

    Wit, J.J.M. de; Harmanny, R.I.A.; Prémel Cabic, G.

    2012-01-01

    Coherent radar measures micro-Doppler properties of moving objects. The micro-Doppler signature depends on parts of an object moving and rotating in addition to the main body motion (e.g. rotor blades) and is therefore characteristic for the type of object. In this study, the micro-Doppler signature

  19. Micro-Doppler Analysis of Small UAVs

    NARCIS (Netherlands)

    Wit, J.J.M. de; Harmanny, R.I.A.; Prémel Cabic, G.

    2012-01-01

    Coherent radar measures micro-Doppler properties of moving objects. The micro-Doppler signature depends on parts of an object moving and rotating in addition to the main body motion (e.g. rotor blades) and is therefore characteristic for the type of object. In this study, the micro-Doppler signature

  20. The Doppler Effect--A New Approach

    Science.gov (United States)

    Allen, J.

    1973-01-01

    Discusses the Doppler effect as it applies to different situations, such as a stationary source of sound with the observer moving, a stationary observer, and the sound source and observer both moving. Police radar, satellite surveillance radar, radar astronomy, and the Doppler navigator, are discussed as applications of Doppler shift. (JR)

  1. Doppler indicates of uterine artery Doppler velocimetry by placental location

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sung Shik; Park, Yong Won; Cho, Jae Sung; Kwon, Hye Kyeung; Kim, Jae Wook [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2001-09-15

    Our purpose was to investigate the relation between the vascular resistance of uterine artery and placental location and to establish the reference value of Doppler index in uterine artery by placental location. Placental location and flow velocity waveforms of both uterine arteries in 7,016 pregnant women after 18 weeks gestation were examined using color Doppler ultrasonography. Placental location was classified as central and lateral placental and the uterine artery with lateral placental were divided into ipsilateral uterine artery (same side of the placental) and contralateral uterine artery (opposite side of the placenta). The uterine artery with central placental was classified as the central uterine artery. Systolic-Diastolic ratio (S/D ratio) of uterine arteries by gestational weeks were calculated and compared with the placental location and perinatal outcomes. In the lateral placental group, the S/D ratio of the contralateral uterine artery was higher than the ipsilateral one (mean=2.08+0.34 vs 1.89+0.34, p=0.0001). S/D ratio of the uterine artery decreased during second trimester and the ratio after 27 weeks was a tendency to have a constant values(ipsilateral: 1.85+ 0.34, central : 1.96+ 0.40, contralateral: 2.01+0.54). S/D ratio of the uterine artery was affected by placental location. So when we evaluate Doppler spectrum of uterine artery, placental location should be considered and we established the reference value of Doppler index of uterine artery by placental location.

  2. Azimuthal Doppler Effect in Optical Vortex Spectroscopy

    Science.gov (United States)

    Aramaki, Mitsutoshi; Yoshimura, Shinji; Toda, Yasunori; Morisaki, Tomohiro; Terasaka, Kenichiro; Tanaka, Masayoshi

    2015-11-01

    Optical vortices (OV) are a set of solutions of the paraxial Helmholtz equation in the cylindrical coordinates, and its wave front has a spiral shape. Since the Doppler shift is caused by the phase change by the movement in a wave field, the observer in the OV, which has the three-dimensional structured wave front, feels a three-dimensional Doppler effect. Since the multi-dimensional Doppler components are mixed into a single Doppler spectrum, development of a decomposition method is required. We performed a modified saturated absorption spectroscopy to separate the components. The OV and plane wave are used as a probe beam and pump beam, respectively. Although the plane-wave pump laser cancels the z-direction Doppler shift, the azimuthal Doppler shift remains in the saturated dip. The spatial variation of the dip width gives the information of the azimuthal Doppler shift. The some results of optical vortex spectroscopy will be presented.

  3. Kalman Orbit Optimized Loop Tracking

    Science.gov (United States)

    Young, Lawrence E.; Meehan, Thomas K.

    2011-01-01

    Under certain conditions of low signal power and/or high noise, there is insufficient signal to noise ratio (SNR) to close tracking loops with individual signals on orbiting Global Navigation Satellite System (GNSS) receivers. In addition, the processing power available from flight computers is not great enough to implement a conventional ultra-tight coupling tracking loop. This work provides a method to track GNSS signals at very low SNR without the penalty of requiring very high processor throughput to calculate the loop parameters. The Kalman Orbit-Optimized Loop (KOOL) tracking approach constitutes a filter with a dynamic model and using the aggregate of information from all tracked GNSS signals to close the tracking loop for each signal. For applications where there is not a good dynamic model, such as very low orbits where atmospheric drag models may not be adequate to achieve the required accuracy, aiding from an IMU (inertial measurement unit) or other sensor will be added. The KOOL approach is based on research JPL has done to allow signal recovery from weak and scintillating signals observed during the use of GPS signals for limb sounding of the Earth s atmosphere. That approach uses the onboard PVT (position, velocity, time) solution to generate predictions for the range, range rate, and acceleration of the low-SNR signal. The low- SNR signal data are captured by a directed open loop. KOOL builds on the previous open loop tracking by including feedback and observable generation from the weak-signal channels so that the MSR receiver will continue to track and provide PVT, range, and Doppler data, even when all channels have low SNR.

  4. Evaluation of cardiac longitudinal systolic function in patients with heart transplant using two dimensional speckle tracking echocardiography and tissue Doppler imaging%二维斑点追踪及组织多普勒技术评价移植心脏纵向收缩功能的临床研究

    Institute of Scientific and Technical Information of China (English)

    李政; 潘翠珍; 舒先红; 陈昊; 王春生

    2014-01-01

    目的 应用二维斑点追踪技术及组织多普勒技术分别评价移植心脏左、右室纵向收缩功能.方法 56例心脏移植患者,根据心内膜心肌活检及长期临床随访结果分为无排异组(A组)和排异组(B组),随机入选36例健康志愿者归入C组,测量左室射血分数(LVEF)、肺动脉收缩压、三尖瓣瓣环位移(TAPSE)和三尖瓣瓣环收缩期速度(TA-S')等指标.应用Qlab 9.0软件分析获得左室整体纵向应变值(global longitudinal strain,GLS).结果 B组较C组LVEF降低(P<0.01).三组间GLS、TAPSE及TA-S'值比较差异均有统计学意义(P均<0.01),B组<A组<C组;GLS与LVEF、TAPSE、TA-S'有较好的负相关性(r分别为-0.64,-0.69,-0.71,P均<0.01).结论 心脏移植患者左、右室纵向收缩功能均有不同程度降低.%Objective To investigate longitudinal systolic function of transplanted heart using two dimensional speckle tracking echocardiography and tissue Doppler imaging.Methods 56 consecutive patients with heart transplant were recruited,according to myocardial biopsy and 1 year's follow up,they were divided into non-rejection group (group A) and rejection group (group B).36 healthy controls (group C) were also randomly recruited.Left ventricular ejection fraction (LVEF),pulmonary arterial systolic pressure,tricuspid annular plane systolic excursion (TAPSE),tricuspid annular plane systolic velocity (TAS') and global longitudinal strain (GLS) were calculated via Qlab 9.0 analysis software offline.Results Compared with group C,LVEF was reduced in group B (P <0.01).Differences of GLS,TAPSE,and TA-S' among groups were all statistically significant (P <0.01),group B<group A< group C.LVEF,TAPSE and TA-S' were correlated with GLS (r =-0.64,r =-0.69,r =-0.71 ; all P < 0.01).Conclusions Left and right ventricles were a functional unity,the systolic function of which was impaired in patients with heart transplant.

  5. Doppler time-of-flight imaging

    KAUST Repository

    Heide, Felix

    2015-07-30

    Over the last few years, depth cameras have become increasingly popular for a range of applications, including human-computer interaction and gaming, augmented reality, machine vision, and medical imaging. Many of the commercially-available devices use the time-of-flight principle, where active illumination is temporally coded and analyzed on the camera to estimate a per-pixel depth map of the scene. In this paper, we propose a fundamentally new imaging modality for all time-of-flight (ToF) cameras: per-pixel velocity measurement. The proposed technique exploits the Doppler effect of objects in motion, which shifts the temporal frequency of the illumination before it reaches the camera. Using carefully coded illumination and modulation frequencies of the ToF camera, object velocities directly map to measured pixel intensities. We show that a slight modification of our imaging system allows for color, depth, and velocity information to be captured simultaneously. Combining the optical flow computed on the RGB frames with the measured metric axial velocity allows us to further estimate the full 3D metric velocity field of the scene. We believe that the proposed technique has applications in many computer graphics and vision problems, for example motion tracking, segmentation, recognition, and motion deblurring.

  6. Velocity-aligned Doppler spectroscopy

    Science.gov (United States)

    Xu, Z.; Koplitz, B.; Wittig, C.

    1989-03-01

    The use of velocity-aligned Doppler spectroscopy (VADS) to measure center-of-mass kinetic-energy distributions of nascent photofragments produced in pulsed-initiation photolysis/probe experiments is described and demonstrated. In VADS, pulsed photolysis and probe laser beams counterpropagate through the ionization region of a time-of-flight mass spectrometer. The theoretical principles of VADS and the mathematical interpretation of VADS data are explained and illustrated with diagrams; the experimental setup is described; and results for the photodissociation of HI, H2S, and NH3 are presented in graphs and characterized in detail. VADS is shown to give much higher kinetic-energy resolution than conventional Doppler spectroscopy.

  7. Analysis and compensation for code Doppler effect of BDS II signal under high dynamics

    Science.gov (United States)

    Ouyang, Xiaofeng; Zeng, Fangling

    2016-01-01

    In high dynamic circumstances, the acquisition of BDS (BeiDou Navigation Satellite System) signal would be affected by the pseudo-code Doppler. The pseudo-code frequency shift is more prominent and complex when BOC modulation has been adopted by BDS-II, but is not yet involved in current compensation algorithm. In addition, the most frequently used code Doppler compensation algorithm is modifying the sampling rate or local bit rate, which not only increases the complexity of the acquisition and tracking, but also is barely realizable for the hardware receiver to modify the local frequency. Therefore, this paper proposes a code Doppler compensation method based on double estimator receiver, which simultaneously controls NCO delay of code tracking loop and subcarrier tracking loop to compensate for pseudo-code frequency shift. The simulation and test are implemented with BDS-II BOC signal. The test results demonstrate that the proposed algorithm can effectively compensate for pseudo-code Doppler of BOC signal and has detection probability 3dB higher than the uncompensated situation when the false alarm rate is under 0.01 and the coherent integration time is 1ms.

  8. Real-time and interactive virtual Doppler ultrasound

    Science.gov (United States)

    Hirji, Samira; Downey, Donal B.; Holdsworth, David W.; Steinman, David A.

    2005-04-01

    This paper describes our "virtual" Doppler ultrasound (DUS) system, in which colour DUS (CDUS) images and DUS spectrograms are generated on-the-fly and displayed in real-time in response to position and orientation cues provided by a magnetically tracked handheld probe. As the presence of complex flow often confounds the interpretation of Doppler ultrasound data, this system will serve to be a fundamental tool for training sonographers and gaining insight into the relationship between ambiguous DUS images and complex blood flow dynamics. Recently, we demonstrated that DUS spectra could be realistically simulated in real-time, by coupling a semi-empirical model of the DUS physics to a 3-D computational fluid dynamics (CFD) model of a clinically relevant flow field. Our system is an evolution of this approach where a motion-tracking device is used to continuously update the origin and orientation of a slice passing through a CFD model of a stenosed carotid bifurcation. After calibrating our CFD model onto a physical representation of a human neck, virtual CDUS images from an instantaneous slice are then displayed at a rate of approximately 15 Hz by simulating, on-the-fly, an array of DUS spectra and colour coding the resulting spectral mean velocity using a traditional Doppler colour scale. Mimicking a clinical examination, the operator can freeze the CDUS image on-screen, and a spectrogram corresponding to the selected sample volume location is rendered at a higher frame rate of at least 30 Hz. All this is achieved using an inexpensive desktop workstation and commodity graphics card.

  9. Radar tracking and classification of littoral targets

    Science.gov (United States)

    Silvious, Jerry; Tahmoush, Dave

    2012-06-01

    Radar can provide inexpensive wide-area surveillance of river and port traffic for both security and emergency response. We demonstrate the tracking of multiple vessels as well as the micro-Doppler signatures of different classes of small vessels, including kayaks and zodiacs. The pattern of life of a river is analyzed over several days and can be used to easily identify suspicious or unusual cases.

  10. DOPPLER ANALYSIS IN PREGNANCY INDUCED HYPERTENSION

    Directory of Open Access Journals (Sweden)

    Tushar

    2014-12-01

    Full Text Available A study of 50 cases was conducted to evaluate the role of Colour Doppler imaging in pregnancy induced hypertension with women over 28 weeks of gestation, the initial scan was performed immediately after the diagnosis of PIH to avoid any influence of treatment on Doppler evaluation. This study was aimed to analyze the blood flow in umbilical artery, maternal uterine artery & fetal middle cerebral artery using Doppler ultrasound.

  11. Emboli detection using the Doppler ultrasound technique

    Institute of Scientific and Technical Information of China (English)

    WANG Yuanyuan; CHEN Xi; ZHANG Yu; WANG Weiqi

    2003-01-01

    Embolic detection is very important to the early diagnosis of vessel disease. The Doppler ultrasound technique is one of the common methods to detect the emboli non-invasively. When the emboli pass through the sample volume of the Doppler ultrasound instrument, there exist high intensity transient Doppler signals. Thus the emboli can be detected directly from the variation of Doppler signal amplitude. Since there may be some disturbance in the system, this general detection method has great limitation. To improve the accuracy of emboli auto-detection, several novel methods are studied to obtain the sensitive characteristic of the emboli signals using the new signal processing theories.

  12. Remote Electromagnetic Vibration of Steerable Needles for Imaging in Power Doppler Ultrasound.

    Science.gov (United States)

    Cabreros, Sarah S; Jimenez, Nina M; Greer, Joseph D; Adebar, Troy K; Okamura, Allison M

    2015-05-01

    Robotic needle steering systems for minimally invasive medical procedures require complementary medical imaging systems to track the needles in real time. Ultrasound is a promising imaging modality because it offers relatively low-cost, real-time imaging of the needle. Previous methods applied vibration to the base of the needle using a voice coil actuator, in order to make the needle visible in power Doppler ultrasound. We propose a new method for needle tip vibration, using electromagnetic actuation of small permanent magnets placed inside the needle to improve needle tip visibility in power Doppler imaging. Robotic needle insertion experiments using artificial tissue and ex vivo porcine liver showed that the electromagnetic tip vibration method can generate a stronger Doppler response compared to the previous base vibration method, resulting in better imaging at greater needle depth in tissue. It also eliminates previous issues with vibration damping along the shaft of the needle.

  13. Proposal for a spaceborne dual-beam rain radar with Doppler capability

    Science.gov (United States)

    Amayenc, Paul; Testud, Jacques; Marzoug, Mongi

    1993-06-01

    The feasibility of adding a Doppler capability to a spaceborne dual-beam radar is discussed. The dual-beam Doppler radar is capable of determining two components of the air velocity: the along-track component of the horizontal air velocity and a component directed between 0 and 20 deg off the vertical. Both components can be calculated with an accuracy of about 1.2 m/s within each resolution cell in standard conditions. THese data can be used by monitoring the mesoscale wind field within stratiform precipitation areas, or by estimating the horizontal transport of vertical momentum associated with deep convection on the climatological level. It is concluded that implementation of the Doppler capability on the radar operating at 24 GHz seems to be possible without jeopardizing the primary objective, i.e., the rain rate estimate at the global scale using a stereo-radar algorithm.

  14. Non-contact physiological signal detection using continuous wave Doppler radar.

    Science.gov (United States)

    Qiao, Dengyu; He, Tan; Hu, Boping; Li, Ye

    2014-01-01

    The aim of this work is to show non-contact physiological signal monitoring system based on continuous-wave (CW) Doppler radar, which is becoming highly attractive in the field of health care monitoring of elderly people. Two radar signal processing methods were introduced in this paper: one to extract respiration and heart rates of a single person and the other to separate mixed respiration signals. To verify the validity of the methods, physiological signal is obtained from stationary human subjects using a CW Doppler radar unit. The sensor operating at 24 GHz is located 0.5 meter away from the subject. The simulation results show that the respiration and heart rates are clearly extracted, and the mixed respiration signals are successfully separated. Finally, reference respiration and heart rate signals are measured by an ECG monitor and compared with the results tracked by the CW Doppler radar monitoring system.

  15. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plas...

  16. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  17. Doppler tomography in fusion plasmas and astrophysics

    NARCIS (Netherlands)

    Salewski, M.; Geiger, B.; Heidbrink, W. W.; Jacobsen, A. S.; Korsholm, S. B.; Leipold, F.; Madsen, J.; Moseev, D.; Nielsen, S.K.; Rasmussen, J.; Stagner, L.; Steeghs, D.; Stejner, M.; Tardini, G.; Weiland, M.; ASDEX Upgrade team,

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion D-alpha (FIDA) spectroscopy measurements in magnetically confined pl

  18. On one-way Doppler measurements of space craft and celestial objects

    Science.gov (United States)

    Jochim, E. F. M.

    2010-01-01

    The orbital velocity of a spacecraft and other celestial objects is monitored by observing the Doppler frequency shift of the signals received at the ground station. This is possible one-way in case the transmitted frequency is stable enough. In most spacecraft a calibrated transponder allows two-way Doppler frequency registrations. In general, the factor 2 is expected as the quotient between two- and one-way frequencies. However, this is no longer the case when the motion of the observed object deviates from the orbit as predicted. Frequency differences appear. Porsche (1999) has published a formula to describe these differences based on the assumption of a double projection of the true velocity vector. In the present paper a more sophisticated analysis of the influence of state errors on the track-ing results is deduced. This theory has been tested by the Doppler measurements during flybys of the comet space probe GIOTTO penetrating through the comae of the comets P/Halley and P/Grigg-Skjellerup. One-way Doppler measurements of the low Earth satellites CHAMP and TERRASAR-X show a tendency for the applicability of this approach. Finally, some conse-quences for the observation of other celestial objects are discussed.

  19. Inverse Doppler Effects in Broadband Acoustic Metamaterials.

    Science.gov (United States)

    Zhai, S L; Zhao, X P; Liu, S; Shen, F L; Li, L L; Luo, C R

    2016-08-31

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with 'flute-like' acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  20. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    Science.gov (United States)

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-08-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  1. Observation of the Zero Doppler Effect

    Science.gov (United States)

    Ran, Jia; Zhang, Yewen; Chen, Xiaodong; Fang, Kai; Zhao, Junfei; Chen, Hong

    2016-04-01

    The normal Doppler effect has well-established applications in many areas of science and technology. Recently, a few experimental demonstrations of the inverse Doppler effect have begun to appear in negative-index metamaterials. Here we report an experimental observation of the zero Doppler effect, that is, no frequency shift irrespective of the relative motion between the wave signal source and the detector in a zero-index metamaterial. This unique phenomenon, accompanied by the normal and inverse Doppler effects, is generated by reflecting a wave from a moving discontinuity in a composite right/left-handed transmission line loaded with varactors when operating in the near zero-index passband, or the right/left-handed passband. This work has revealed a complete picture of the Doppler effect in metamaterials and may lead to potential applications in electromagnetic wave related metrology.

  2. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  3. Color doppler sonography in thickened gallbladder wall

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki [Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    1996-11-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes.

  4. xD-Track: Leveraging Multi-Dimensional Information for Passive Wi-Fi Tracking

    OpenAIRE

    Xie, Y.; XIONG, J.; Li, M; Jamieson, K.

    2016-01-01

    We describe the design and implementation of xD-Track, the first practical Wi-Fi based device-free localization system that employs a simultaneous and joint estimation of time-of-flight, angle-of-arrival, angle-of-departure, and Doppler shift to fully characterize the wireless channel between a sender and receiver. Using this full characterization, xD-Track introduces novel methods to measure and isolate the signal path that reflects off a person of interest, allowing it to localize a human w...

  5. Optical Doppler tomography and spectral Doppler imaging of localized ischemic stroke in a mouse model

    Science.gov (United States)

    Yu, Lingfeng; Nguyen, Elaine; Liu, Gangjun; Rao, Bin; Choi, Bernard; Chen, Zhongping

    2010-02-01

    We present a combined optical Doppler tomography/spectral Doppler imaging modality to quantitatively evaluate the dynamic blood circulation and the artery blockage before and after a localized ischemic stroke in a mouse model. Optical Doppler Tomography (ODT) combines the Doppler principle with optical coherence tomography for noninvasive localization and measurement of particle flow velocity in highly scattering media with micrometer scale spatial resolution. Spectral Doppler imaging (SDI) provides complementary temporal flow information to the spatially distributed flow information of Doppler imaging. Fast, repeated, ODT scans across an entire vessel were performed to record flow dynamic information with high temporal resolution of cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time for scatters within the imaging volume using spectral Doppler waveforms. Furthermore, vascular conditions can be quantified with various Doppler-angle-independent flow indices. Non-invasive in-vivo mice experiments were performed to evaluate microvascular blood circulation of a localized ischemic stroke mouse model.

  6. Tracking Porters

    DEFF Research Database (Denmark)

    Bruun, Maja Hojer; Krause-Jensen, Jakob; Saltofte, Margit

    2015-01-01

    Anthropology attempts to gain insight into people's experiential life-worlds through long-term fieldwork. The quality of anthropological knowledge production, however, does not depend solely on the duration of the stay in the field, but also on a particular way of seeing social situations. The an...... the students followed the work of a group of porters. Drawing on anthropological concepts and research strategies the students gained crucial insights about the potential effects of using tracking technologies in the hospital....

  7. Wideband radar micro-doppler applications

    Science.gov (United States)

    Tahmoush, Dave

    2013-05-01

    Wideband radar provides a significant improvement over traditional narrowband radars for micro-Doppler analysis because the high bandwidth can be used to separate many of the signals in range, allowing a simpler decomposition of the micro-Doppler signals. Recent wideband radar work has focused on micro-Doppler, but there is a point where the narrowband approach used to analyze the micro-Doppler signals breaks down. The effect is shown to be independent of frequency, but the error relative to the bandwidth is shown to be inversely proportional to the frequency and proportional to the velocity of the subject. This error can create a smearing effect in the observed Doppler if it is not corrected, leading to reduced signal-to-noise and the appearance of more diffuse targets in Doppler space. In range-space, wideband data can also break the subject into several range bins, affecting the observed signal to noise ratio. The possible applications of wideband micro-Doppler radar are also shown, including the separation of arm movement from human motion which implies that the arms are not encumbered.

  8. Rotational Doppler effect in nonlinear optics

    Science.gov (United States)

    Li, Guixin; Zentgraf, Thomas; Zhang, Shuang

    2016-08-01

    The translational Doppler effect of electromagnetic and sound waves has been successfully applied in measurements of the speed and direction of vehicles, astronomical objects and blood flow in human bodies, and for the Global Positioning System. The Doppler effect plays a key role for some important quantum phenomena such as the broadened emission spectra of atoms and has benefited cooling and trapping of atoms with laser light. Despite numerous successful applications of the translational Doppler effect, it fails to measure the rotation frequency of a spinning object when the probing wave propagates along its rotation axis. This constraint was circumvented by deploying the angular momentum of electromagnetic waves--the so-called rotational Doppler effect. Here, we report on the demonstration of rotational Doppler shift in nonlinear optics. The Doppler frequency shift is determined for the second harmonic generation of a circularly polarized beam passing through a spinning nonlinear optical crystal with three-fold rotational symmetry. We find that the second harmonic generation signal with circular polarization opposite to that of the fundamental beam experiences a Doppler shift of three times the rotation frequency of the optical crystal. This demonstration is of fundamental significance in nonlinear optics, as it provides us with insight into the interaction of light with moving media in the nonlinear optical regime.

  9. Staggered Multiple-PRF Ultrafast Color Doppler.

    Science.gov (United States)

    Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien

    2016-06-01

    Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.

  10. Global Lunar Gravity Field Recovery from SELENE

    Science.gov (United States)

    Matsumoto, Koji; Heki, Kosuke; Hanada, Hideo

    2002-01-01

    Results of numerical simulation are presented to examine the global gravity field recovery capability of the Japanese lunar exploration project SELENE (Selenological and Engineering Explorer) which will be launched in 2005. New characteristics of the SELENE lunar gravimetry include four-way satellite-to-satellite Doppler tracking of main orbiter and differential VLBI tracking of two small free-flier satellites. It is shown that planned satellites configuration will improve lunar gravity field in wide range of wavelength as well as far-side selenoid.

  11. Users Guide to the JPL Doppler Gravity Database

    Science.gov (United States)

    Muller, P. M.; Sjogren, W. L.

    1986-01-01

    Local gravity accelerations and gravimetry have been determined directly from spacecraft Doppler tracking data near the Moon and various planets by the Jet Propulsion Laboratory. Researchers in many fields have an interest in planet-wide global gravimetric mapping and its applications. Many of them use their own computers in support of their studies and would benefit from being able to directly manipulate these gravity data for inclusion in their own modeling computations. Pubication of some 150 Apollo 15 subsatellite low-altitude, high-resolution, single-orbit data sets is covered. The doppler residuals with a determination of the derivative function providing line-of-sight-gravity are both listed and plotted (on microfilm), and can be ordered in computer readable forms (tape and floppy disk). The form and format of this database as well as the methods of data reduction are explained and referenced. A skeleton computer program is provided which can be modified to support re-reductions and re-formatted presentations suitable to a wide variety of research needs undertaken on mainframe or PC class microcomputers.

  12. Dynamic range studies and improvements for multiplexed photonic Doppler velocimetry

    Science.gov (United States)

    Miller, Edward Kirk; Lee, Kevin; Larson, Eric; Daykin, Edward

    2017-01-01

    We present studies of the dynamic range achievable with multiplexed photonic Doppler velocimetry (MPDV) measurements, and we demonstrate some techniques to extend the dynamic range. Improved dynamic range for MPDV measurements is needed in order to track the velocity of the free surface behind a cloud of ejecta, so we have undertaken theoretical and experimental studies of factors affecting dynamic range, particularly in cases where the large number of MPDV probe points precludes high illumination power on each channel. To quantify the potential dynamic range of a given MPDV configuration, we introduce a metric called the frequency-domain number of bits, FNOB, which is less stringent than the formally defined equivalent number of bits (ENOB). This new metric is simple to compute in the lab, and it is well suited to conventional PDV analysis, which does not require digitizer phase coherence beyond tens of nanoseconds.

  13. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment.

    Science.gov (United States)

    Ramnarine, K V; Hoskins, P R; Routh, H F; Davidson, F

    1999-01-01

    The Doppler backscatter properties of a blood-mimickig fluid (BMF) were studied to evaluate its suitability for use in a Doppler flow test object. Measurements were performed using a flow rig with C-flex tubing and BMF flow produced by a roller pump or a gear pump. A SciMed Doppler system was used to measure the backscattered Doppler power with a root-mean-square power meter connected to the audio output. Studies investigated the dependence of the backscattered Doppler power of the BMF with: circulation time; batch and operator preparations; storage; sieve size; flow speed; and pump type. A comparison was made with human red blood cells resuspended in saline. The backscatter properties are stable and within International Electrotechnical Commission requirements. The BMF is suitable for use in a test object for Doppler performance assessment.

  14. A laser-lock concept to reach cm/s-precision in Doppler experiments with Fabry-Perot wavelength calibrators

    CERN Document Server

    Reiners, A; Ulbrich, R G

    2014-01-01

    State-of-the-art Doppler experiments require wavelength calibration with precision at the cm/s level. A low-finesse Fabry-Perot interferometer (FPI) can provide a wavelength comb with a very large bandwidth as required for astronomical experiments, but unavoidable spectral drifts are difficult to control. Instead of actively controlling the FPI cavity, we propose to passively stabilize the interferometer and track the time-dependent cavity length drift externally. A dual-finesse cavity allows drift tracking during observation. The drift of the cavity length is monitored in the high-finesse range relative to an external standard: a single narrow transmission peak is locked to an external cavity diode laser and compared to an atomic frequency. Following standard locking schemes, tracking at sub-mm/s precision can be achieved. This is several orders of magnitude better than currently planned high-precision Doppler experiments. It allows freedom for relaxed designs rendering this approach particularly interesting...

  15. Doppler echocardiography in normal functioning valve prostheses.

    Science.gov (United States)

    Cha, R; Yang, S S; Salvucci, T; DiBlasi, S

    1994-09-01

    Even though there has been some criticism regarding the Doppler evaluation in prosthetic valves because of inter-observer and intra-observer variability, among other factors, and Doppler study has a tendency to have falsely high gradients compared to invasive studies, especially mechanical aortic prostheses, Doppler evaluation can provide reliable hemodynamic information about valve function. This test may be particularly useful if used serially, when baseline values are known. Doppler measurement of gradient and valve area has an expected normal range that is specific for the prosthetic type, size, anatomical position, and chronological age. Clearly, a database involving these aspects is needed to provide a more accurate normal range. This study is intended to provide guidance for echocardiographers.

  16. Teaching the Doppler effect in astrophysics

    Science.gov (United States)

    Hughes, Stephen W.; Cowley, Michael

    2017-03-01

    The Doppler effect is a shift in the frequency of waves emitted from an object moving relative to the observer. By observing and analysing the Doppler shift in electromagnetic waves from astronomical objects, astronomers gain greater insight into the structure and operation of our Universe. In this paper, a simple technique is described for teaching the basics of the Doppler effect to undergraduate astrophysics students using acoustic waves. An advantage of the technique is that it produces a visual representation of the acoustic Doppler shift. The equipment comprises a 40 kHz acoustic transmitter and a microphone. The sound is bounced off a computer fan and the signal collected by a DrDAQ ADC and processed by a spectrum analyser. Widening of the spectrum is observed as the fan power supply potential is increased from 4 to 12 V.

  17. High range resolution micro-Doppler analysis

    Science.gov (United States)

    Cammenga, Zachary A.; Smith, Graeme E.; Baker, Christopher J.

    2015-05-01

    This paper addresses use of the micro-Doppler effect and the use of high range-resolution profiles to observe complex targets in complex target scenes. The combination of micro-Doppler and high range-resolution provides the ability to separate the motion of complex targets from one another. This ability leads to the differentiation of targets based on their micro-Doppler signatures. Without the high-range resolution, this would not be possible because the individual signatures would not be separable. This paper also addresses the use of the micro-Doppler information and high range-resolution profiles to generate an approximation of the scattering properties of a complex target. This approximation gives insight into the structure of the complex target and, critically, is created without using a pre-determined target model.

  18. High Throughput Direct Detection Doppler Lidar Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Lite Cycles, Inc. (LCI) proposes to develop a direct-detection Doppler lidar (D3L) technology called ELITE that improves the system optical throughput by more than...

  19. Student Microwave Experiments Involving the Doppler Effect.

    Science.gov (United States)

    Weber, F. Neff; And Others

    1980-01-01

    Described is the use of the Doppler Effect with microwaves in the measurement of the acceleration due to gravity of falling objects. The experiments described add to the repertoire of quantitative student microwave experiments. (Author/DS)

  20. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    National Research Council Canada - National Science Library

    Zhai, S L; Zhao, X P; Liu, S; Shen, F L; Li, L L; Luo, C R

    2016-01-01

    .... With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally...

  1. Optical Doppler shift with structured light

    OpenAIRE

    2011-01-01

    When a light beam with a transverse spatially varying phase is considered for optical remote sensing, in addition to the usual longitudinal Doppler frequency shift of the returned signal induced by the motion of the scatter along the beam axis, a new transversal Doppler shift appears associated to the motion of the scatterer in the plane perpendicular to the beam axis. We discuss here how this new effect can be used to enhance the current capabilities of optical measurement system...

  2. with Ultrasound Color Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Shin Takayama

    2012-01-01

    Full Text Available Color Doppler imaging (CDI can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteers, but was significantly higher after needle stimulation than before. LR3 stimulation also resulted in a significant decrease in the vascular resistance of the short posterior ciliary artery and no significant change of blood flow through the superior mesenteric artery (SMA during acupuncture. In contrast, ST36 stimulation resulted in a significant increase in blood flow through the SMA and no significant change in the vascular resistance of the retrobulbar arteries. Additionally, acupuncture at previously determined acupoints in patients with open-angle glaucoma led to a significant reduction in the vascular resistance of the central retinal artery and short posterior ciliary artery. Our results suggest that acupuncture can affect blood flow of the peripheral, mesenteric, and retrobulbar arteries, and CDI can be useful to evaluate hemodynamic changes by acupuncture.

  3. Saturn's Doppler velocimetry wind measurements with VLT/UVES

    Science.gov (United States)

    Silva, Miguel; Mota Machado, Pedro; Luz, David; Sanchez-Lavega, Agustin; Hueso, Ricardo; Peralta, Javier

    2016-10-01

    presence of the rings lead to severe order superposition.Finally, we will compare our Doppler wind velocity results with the first cloud tracked winds based on Cassini's observations, providing an independent set of observations.

  4. Doppler micro sense and avoid radar

    Science.gov (United States)

    Gorwara, Ashok; Molchanov, Pavlo; Asmolova, Olga

    2015-10-01

    There is a need for small Sense and Avoid (SAA) systems for small and micro Unmanned Aerial Systems (UAS) to avoid collisions with obstacles and other aircraft. The proposed SAA systems will give drones the ability to "see" close up and give them the agility to maneuver through tight areas. Doppler radar is proposed for use in this sense and avoid system because in contrast to optical or infrared (IR) systems Doppler can work in more harsh conditions such as at dusk, and in rain and snow. And in contrast to ultrasound based systems, Doppler can better sense small sized obstacles such as wires and it can provide a sensing range from a few inches to several miles. An SAA systems comprised of Doppler radar modules and an array of directional antennas that are distributed around the perimeter of the drone can cover the entire sky. These modules are designed so that they can provide the direction to the obstacle and simultaneously generate an alarm signal if the obstacle enters within the SAA system's adjustable "Protection Border". The alarm signal alerts the drone's autopilot to automatically initiate an avoidance maneuver. A series of Doppler radar modules with different ranges, angles of view and transmitting power have been designed for drones of different sizes and applications. The proposed Doppler radar micro SAA system has simple circuitry, works from a 5 volt source and has low power consumption. It is light weight, inexpensive and it can be used for a variety of small unmanned aircraft.

  5. The Doppler effect in NMR spectroscopy.

    Science.gov (United States)

    Guéron, Maurice

    2003-02-01

    An NMR sample may be subject to motions, such as those due to sample spinning or to liquid flow. Is the spectrum of such a sample affected by the Doppler effect? The question arises because, instrumental dimensions being much shorter than the wavelength, it is the near-field of the precessing magnetic moment which couples to the receiver coil, rather than the radiated far-field. We expand the near-field into plane propagating waves. For each such wave there is another one with the same amplitude, propagating in the opposite direction. The Doppler shifts are therefore equal and opposite. In the model case of a small fluid sample moving with constant velocity, this leads to a distribution of Doppler shifts which is symmetrical with respect to the unshifted frequency: there is no net spectral shift. We examine the possibility of observing the Doppler distribution in this case. We also consider the case of thermal motion of a gas. We draw attention to the resolved Doppler splitting of molecular rotational transitions in a supersonic burst as observed in a microwave resonator. We also mention briefly the Doppler effect in molecular beam spectroscopy.

  6. Tracking telecommuting

    Energy Technology Data Exchange (ETDEWEB)

    Stastny, P.

    2007-03-15

    Many employees are now choosing to work from home using laptops and telephones. Employers in the oil and gas industry are now reaping a number of benefits from their telecommuting employees, including increased productivity; higher levels of employee satisfaction, and less absenteeism. Providing a telecommunication option can prove to be advantageous for employers wishing to hire or retain employees. Telecommuting may also help to reduce greenhouse gas (GHG) emissions. This article provided details of Teletrips Inc., a company that aids in the production of corporate social responsibility reports. Teletrips provides reports that document employee savings in time, vehicle depreciation maintenance, and gasoline costs. Teletrips currently tracks 12 companies in Calgary, and plans to grow through the development of key technology partnerships. The company is also working with the federal government to provide their clients with emission trading credits, and has forged a memorandum of understanding with the British Columbia government for tracking emissions. Calgary now openly supports telecommuting and is encouraging businesses in the city to adopt telecommuting on a larger scale. It was concluded that the expanding needs for road infrastructure and the energy used by cars to move workers in and out of the city are a massive burden to the city's tax base. 1 fig.

  7. INNER TRACKING

    CERN Multimedia

    P. Sharp

    The CMS Inner Tracking Detector continues to make good progress. The Objective for 2006 was to complete all of the CMS Tracker sub-detectors and to start the integration of the sub-detectors into the Tracker Support Tube (TST). The Objective for 2007 is to deliver to CMS a completed, installed, commissioned and calibrated Tracking System (Silicon Strip and Pixels) aligned to < 100µ in April 2008 ready for the first physics collisions at LHC. In November 2006 all of the sub-detectors had been delivered to the Tracker Integration facility (TIF) at CERN and the tests and QA procedures to be carried out on each sub-detector before integration had been established. In December 2006, TIB/TID+ was integrated into TOB+, TIB/TID- was being prepared for integration, and TEC+ was undergoing tests at the final tracker operating temperature (-100 C) in the Lyon cold room. In February 2007, TIB/TID- has been integrated into TOB-, and the installation of the pixel support tube and the services for TI...

  8. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  9. AMSNEXRAD-Automated detection of meteorite strewnfields in doppler weather radar

    Science.gov (United States)

    Hankey, Michael; Fries, Marc; Matson, Rob; Fries, Jeff

    2017-09-01

    For several years meteorite recovery in the United States has been greatly enhanced by using Doppler weather radar images to determine possible fall zones for meteorites produced by witnessed fireballs. While most fireball events leave no record on the Doppler radar, some large fireballs do. Based on the successful recovery of 10 meteorite falls 'under the radar', and the discovery of radar on more than 10 historic falls, it is believed that meteoritic dust and or actual meteorites falling to the ground have been recorded on Doppler weather radar (Fries et al., 2014). Up until this point, the process of detecting the radar signatures associated with meteorite falls has been a manual one and dependent on prior accurate knowledge of the fall time and estimated ground track. This manual detection process is labor intensive and can take several hours per event. Recent technological developments by NOAA now help enable the automation of these tasks. This in combination with advancements by the American Meteor Society (Hankey et al., 2014) in the tracking and plotting of witnessed fireballs has opened the possibility for automatic detection of meteorites in NEXRAD Radar Archives. Here in the processes for fireball triangulation, search area determination, radar interfacing, data extraction, storage, search, detection and plotting are explained.

  10. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  11. INNER TRACKING

    CERN Multimedia

    P. Sharp

    The CMS Inner Tracking Detector continues to make good progress. The successful commissioning of ~ 25% of the Silicon Strip Tracker was completed in the Tracker Integration Facility (TIF) at CERN in July 2007 and the Tracker has since been prepared for moving and installation into CMS at P5. The Tracker was ready to move on schedule in September 2007. The Installation of the Tracker cooling pipes and LV cables between Patch Panel 1 (PP1) on the inside the CMS magnet cryostat, and the cooling plants and power system racks on the balconies has been completed. The optical fibres from PP1 to the readout FEDs in the USC have been installed, together with the Tracker cable channels, in parallel with the installation of the EB/HB services. All of the Tracker Safety, Power, DCS and the VME Readout Systems have been installed at P5 and are being tested and commissioned with CMS. It is planned to install the Tracker into CMS before Christmas. The Tracker will then be connected to the pre-installed services on Y...

  12. INNER TRACKING

    CERN Multimedia

    P. Sharp

    The CMS Inner Tracking Detector continues to make good progress. The successful commissioning of ~ 25% of the Silicon Strip Tracker was completed in the Tracker Integration Facility (TIF) at CERN on 18 July 2007 and the Tracker has since been prepared for moving and installation into CMS at P5. The Tracker will be ready to move on schedule in September 2007. The Installation of the Tracker cooling pipes and LV cables between Patch Panel 1 (PP1) on the inside the CMS magnet cryostat, and the cooling plants and power system racks on the balconies has been completed. The optical fibres from PP1 to the readout FEDs in the USC will be installed in parallel with the installation of the EB/HB services, and will be completed in October. It is planned to install the Tracker into CMS at the end of October, after the completion of the installation of the EB/HB services. The Tracker will then be connected to the pre-installed services on YB0 and commissioned with CMS in December. The FPix and BPix continue to make ...

  13. Patient Treatment Tracking Chart

    Science.gov (United States)

    ... ZIP code here Hepatitis C Treatment Tracking Chart Patient Treatment Tracking Chart Patient Treatment Tracking Chart Sample Chart This chart is ... this website Submit Share this page Related Resource Patient Treatment Tutorial return to top CONNECT Veterans Crisis ...

  14. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1996-06-15

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  15. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  16. Color Doppler ultrasonography evaluation of amblyopia

    Directory of Open Access Journals (Sweden)

    Ece Turan-Vural

    2013-07-01

    Full Text Available AIM: To assess the hemodynamic changes in the extraocular orbital vessels of amblyopic patients in comparison with non-amblyopic fellow eyes, using color Doppler ultrasonography(CDU. METHODS: Thirty-six eyes of 18 pediatric patients were included in the study(20 amblyopic, 16 normal. All eyes underwent color Doppler ultrasonography examination of ophthalmic artery, central retinal artery, and posterior ciliary artery. RESULTS: The only differences between the two groups with regard to color Doppler ultrasonography parameters was the significantly lower peak systolic velocity(32.70±11.60 vs 55.01±11.68, P=0.001and end-diastolic velocity(6.83±1.91 vs 13.99±4.15, P=0.001for ophthalmic artery in amblyopic eyes.CONCLUSION: Our study showed amblyopic eyes may present a decrease in retrobulbar blood flow velocity.

  17. Online transcranial Doppler ultrasonographic control of an onscreen keyboard.

    Science.gov (United States)

    Lu, Jie; Mamun, Khondaker A; Chau, Tom

    2014-01-01

    Brain-computer interface (BCI) systems exploit brain activity for generating a control command and may be used by individuals with severe motor disabilities as an alternative means of communication. An emerging brain monitoring modality for BCI development is transcranial Doppler ultrasonography (TCD), which facilitates the tracking of cerebral blood flow velocities associated with mental tasks. However, TCD-BCI studies to date have exclusively been offline. The feasibility of a TCD-based BCI system hinges on its online performance. In this paper, an online TCD-BCI system was implemented, bilaterally tracking blood flow velocities in the middle cerebral arteries for system-paced control of a scanning keyboard. Target letters or words were selected by repetitively rehearsing the spelling while imagining the writing of the intended word, a left-lateralized task. Undesired letters or words were bypassed by performing visual tracking, a non-lateralized task. The keyboard scanning period was 15 s. With 10 able-bodied right-handed young adults, the two mental tasks were differentiated online using a Naïve Bayes classification algorithm and a set of time-domain, user-dependent features. The system achieved an average specificity and sensitivity of 81.44 ± 8.35 and 82.30 ± 7.39%, respectively. The level of agreement between the intended and machine-predicted selections was moderate (κ = 0.60). The average information transfer rate was 0.87 bits/min with an average throughput of 0.31 ± 0.12 character/min. These findings suggest that an online TCD-BCI can achieve reasonable accuracies with an intuitive language task, but with modest throughput. Future interface and signal classification enhancements are required to improve communication rate.

  18. Numerical RCS and micro-Doppler investigations of a consumer UAV

    Science.gov (United States)

    Schröder, Arne; Aulenbacher, Uwe; Renker, Matthias; Böniger, Urs; Oechslin, Roland; Murk, Axel; Wellig, Peter

    2016-10-01

    This contribution gives an overview of recent investigations regarding the detection of a consumer market unmanned aerial vehicles (UAV). The steadily increasing number of such drones gives rise to the threat of UAVs interfering civil air traffic. Technologies for monitoring UAVs which are flying in restricted air space, i. e. close to airports or even over airports, are desperately needed. One promising way for tracking drones is to employ radar systems. For the detection and classification of UAVs, the knowledge about their radar cross section (RCS) and micro-Doppler signature is of particular importance. We have carried out numerical and experimental studies of the RCS and the micro-Doppler of an example commercial drone in order to study its detectability with radar systems.

  19. Study on the method of polarization suppression of cheating jamming in pulse Doppler radar

    Institute of Scientific and Technical Information of China (English)

    Song Lizhong; Qiao Xiaolin; Meng Xiande; Jin Ming

    2005-01-01

    A jamming suppression method based on polarization signal detection is proposed under common range and velocity cheating jammingfor pulse Doppler radar. On the basis of the separation of the target and the jamming, the range and velocity track on the true target are realized. Firstly the signal processing model of the full polarization pulse Doppler radar is introduced. Secondly the method of correct target separation is discussed, which is the twice detections of energy and polarization state on the two dimension resolution cells of range and velocity of the radar echo. Finally the simulations are performed and the results prove the validity. What' s more, multiple range and velocity cheating jamming can be suppressed at the same time if the target and the jamming are different in the polarization domain.

  20. TIMED Doppler Interferometer on the Thermosphere Ionosphere Mesosphere Energetics and Dynamics satellite: Data product overview

    Science.gov (United States)

    Niciejewski, R.; Wu, Q.; Skinner, W.; Gell, D.; Cooper, M.; Marshall, A.; Killeen, T.; Solomon, S.; Ortland, D.

    2006-11-01

    The TIMED Doppler Interferometer (TIDI) performs the measurement of upper atmospheric winds on the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) satellite. This is an optimized single etalon Fabry Perot interferometer that records the slight Doppler shift of individual emission features of the O2 (0,0) atmospheric band. The interferometer operates at a 100% duty cycle obtaining neutral wind altitude profiles on a global basis. The measurements are synoptic and provide an uninterrupted long-term climatological record of the dynamics in the mesosphere and lower thermosphere regions. The data products from TIDI include (1) apparent line of sight winds and integrated brightness, (2) inverted line of sight winds and volume emission rate, and (3) inverted horizontal neutral wind fields on an evenly spaced track angle/altitude grid. The data products demonstrate an interannual variability in the tidal structure of the mesosphere and the lower thermosphere and an inherent daily geophysical variance.

  1. Observation of the inverse Doppler effect.

    Science.gov (United States)

    Seddon, N; Bearpark, T

    2003-11-28

    We report experimental observation of an inverse Doppler shift, in which the frequency of a wave is increased on reflection from a receding boundary. This counterintuitive effect has been produced by reflecting a wave from a moving discontinuity in an electrical transmission line. Doppler shifts produced by this system can be varied in a reproducible manner by electronic control of the transmission line and are typically five orders of magnitude greater than those produced by solid objects with kinematic velocities. Potential applications include the development of tunable and multifrequency radiation sources.

  2. Reversed Doppler effect in photonic crystals.

    Science.gov (United States)

    Reed, Evan J; Soljacić, Marin; Joannopoulos, John D

    2003-09-26

    Nonrelativistic reversed Doppler shifts have never been observed in nature and have only been speculated to occur in pathological systems with simultaneously negative effective permittivity and permeability. This Letter presents a different, new physical phenomenon that leads to a nonrelativistic reversed Doppler shift in light. It arises when light is reflected from a moving shock wave propagating through a photonic crystal. In addition to reflection of a single frequency, multiple discrete reflected frequencies or a 10 GHz periodic modulation can also be observed when a single carrier frequency of wavelength 1 microm is incident.

  3. Preprocessing of ionospheric echo Doppler spectra

    Institute of Scientific and Technical Information of China (English)

    FANG Liang; ZHAO Zhengyu; WANG Feng; SU Fanfan

    2007-01-01

    The real-time information of the distant ionosphere can be acquired by using the Wuhan ionospheric oblique backscattering sounding system(WIOBSS),which adopts a discontinuous wave mechanism.After the characteristics of the ionospheric echo Doppler spectra were analyzed,the signal preprocessing was developed in this paper,which aimed at improving the Doppler spectra.The results indicate that the preprocessing not only makes the system acquire a higher ability of target detection but also suppresses the radio frequency interference by 6-7 dB.

  4. Optical Doppler shift with structured light.

    Science.gov (United States)

    Belmonte, Aniceto; Torres, Juan P

    2011-11-15

    When a light beam with a transverse spatially varying phase is considered for optical remote sensing, in addition to the usual longitudinal Doppler frequency shift of the returned signal induced by the motion of the scatter along the beam axis, a new transversal Doppler shift appears associated to the motion of the scatterer in the plane perpendicular to the beam axis. We discuss here how this new effect can be used to enhance the current capabilities of optical measurement systems, adding the capacity to detect more complex movements of scatters.

  5. Magnetic Doppler Imaging of Active Stars

    CERN Document Server

    Kochukhov, O

    2007-01-01

    We present a new implementation of the magnetic Doppler imaging technique, which aims at self-consistent temperature and magnetic mapping of the surface structures in cool active stars. Our magnetic imaging procedure is unique in its capability to model individual spectral features in all four Stokes parameters. We discuss performance and intrinsic limitations of the new magnetic Doppler imaging method. A special emphasis is given to the simultaneous modelling of the magnetically sensitive lines in the optical and infrared regions and to combining information from both atomic and molecular spectral features. These two techniques may, for the first time, give us a tool to study magnetic fields in the starspot interiors.

  6. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  7. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  8. Fish embryo multimodal imaging by laser Doppler digital holography

    CERN Document Server

    Verrier, Nicolas; Picart, Pascal; Gross, Michel

    2015-01-01

    A laser Doppler imaging scheme combined to an upright microscope is proposed. Quantitative Doppler imaging in both velocity norm and direction, as well as amplitude contrast of either zebrafish flesh or vasculature is demonstrated.

  9. A micro-Doppler sonar for acoustic surveillance in sensor networks

    Science.gov (United States)

    Zhang, Zhaonian

    Wireless sensor networks have been employed in a wide variety of applications, despite the limited energy and communication resources at each sensor node. Low power custom VLSI chips implementing passive acoustic sensing algorithms have been successfully integrated into an acoustic surveillance unit and demonstrated for detection and location of sound sources. In this dissertation, I explore active and passive acoustic sensing techniques, signal processing and classification algorithms for detection and classification in a multinodal sensor network environment. I will present the design and characterization of a continuous-wave micro-Doppler sonar to image objects with articulated moving components. As an example application for this system, we use it to image gaits of humans and four-legged animals. I will present the micro-Doppler gait signatures of a walking person, a dog and a horse. I will discuss the resolution and range of this micro-Doppler sonar and use experimental results to support the theoretical analyses. In order to reduce the data rate and make the system amenable to wireless sensor networks, I will present a second micro-Doppler sonar that uses bandpass sampling for data acquisition. Speech recognition algorithms are explored for biometric identifications from one's gait, and I will present and compare the classification performance of the two systems. The acoustic micro-Doppler sonar design and biometric identification results are the first in the field as the previous work used either video camera or microwave technology. I will also review bearing estimation algorithms and present results of applying these algorithms for bearing estimation and tracking of moving vehicles. Another major source of the power consumption at each sensor node is the wireless interface. To address the need of low power communications in a wireless sensor network, I will also discuss the design and implementation of ultra wideband transmitters in a three dimensional

  10. Compact, High Energy 2-micron Coherent Doppler Wind Lidar Development for NASA's Future 3-D Winds Measurement from Space

    Science.gov (United States)

    Singh, Upendra N.; Koch, Grady; Yu, Jirong; Petros, Mulugeta; Beyon, Jeffrey; Kavaya, Michael J.; Trieu, Bo; Chen, Songsheng; Bai, Yingxin; Petzar, paul; Modlin, Edward A.; Barnes, Bruce W.; Demoz, Belay B.

    2010-01-01

    This paper presents an overview of 2-micron laser transmitter development at NASA Langley Research Center for coherent-detection lidar profiling of winds. The novel high-energy, 2-micron, Ho:Tm:LuLiF laser technology developed at NASA Langley was employed to study laser technology currently envisioned by NASA for future global coherent Doppler lidar winds measurement. The 250 mJ, 10 Hz laser was designed as an integral part of a compact lidar transceiver developed for future aircraft flight. Ground-based wind profiles made with this transceiver will be presented. NASA Langley is currently funded to build complete Doppler lidar systems using this transceiver for the DC-8 aircraft in autonomous operation. Recently, LaRC 2-micron coherent Doppler wind lidar system was selected to contribute to the NASA Science Mission Directorate (SMD) Earth Science Division (ESD) hurricane field experiment in 2010 titled Genesis and Rapid Intensification Processes (GRIP). The Doppler lidar system will measure vertical profiles of horizontal vector winds from the DC-8 aircraft using NASA Langley s existing 2-micron, pulsed, coherent detection, Doppler wind lidar system that is ready for DC-8 integration. The measurements will typically extend from the DC-8 to the earth s surface. They will be highly accurate in both wind magnitude and direction. Displays of the data will be provided in real time on the DC-8. The pulsed Doppler wind lidar of NASA Langley Research Center is much more powerful than past Doppler lidars. The operating range, accuracy, range resolution, and time resolution will be unprecedented. We expect the data to play a key role, combined with the other sensors, in improving understanding and predictive algorithms for hurricane strength and track. 1

  11. Planetary Radio Interferometry and Doppler Experiment (PRIDE) technique: A test case of the Mars Express Phobos fly-by

    Science.gov (United States)

    Duev, D. A.; Pogrebenko, S. V.; Cimò, G.; Molera Calvés, G.; Bocanegra Bahamón, T. M.; Gurvits, L. I.; Kettenis, M. M.; Kania, J.; Tudose, V.; Rosenblatt, P.; Marty, J.-C.; Lainey, V.; de Vicente, P.; Quick, J.; Nickola, M.; Neidhardt, A.; Kronschnabl, G.; Ploetz, C.; Haas, R.; Lindqvist, M.; Orlati, A.; Ipatov, A. V.; Kharinov, M. A.; Mikhailov, A. G.; Lovell, J. E. J.; McCallum, J. N.; Stevens, J.; Gulyaev, S. A.; Natush, T.; Weston, S.; Wang, W. H.; Xia, B.; Yang, W. J.; Hao, L.-F.; Kallunki, J.; Witasse, O.

    2016-09-01

    Context. The closest ever fly-by of the Martian moon Phobos, performed by the European Space Agency's Mars Express spacecraft, gives a unique opportunity to sharpen and test the Planetary Radio Interferometry and Doppler Experiments (PRIDE) technique in the interest of studying planet-satellite systems. Aims: The aim of this work is to demonstrate a technique of providing high precision positional and Doppler measurements of planetary spacecraft using the Mars Express spacecraft. The technique will be used in the framework of Planetary Radio Interferometry and Doppler Experiments in various planetary missions, in particular in fly-by mode. Methods: We advanced a novel approach to spacecraft data processing using the techniques of Doppler and phase-referenced very long baseline interferometry spacecraft tracking. Results: We achieved, on average, mHz precision (30 μm/s at a 10 s integration time) for radial three-way Doppler estimates and sub-nanoradian precision for lateral position measurements, which in a linear measure (at a distance of 1.4 AU) corresponds to ~50 m.

  12. Planetary Radio Interferometry and Doppler Experiment (PRIDE) technique: A test case of the Mars Express Phobos fly-by

    CERN Document Server

    Duev, Dmitry A; Cimò, Giuseppe; Calvés, Guifré Molera; Bahamón, Tatiana M Bocanegra; Gurvits, Leonid I; Kettenis, Mark M; Kania, Joseph; Tudose, Valeriu; Rosenblatt, Pascal; Marty, Jean-Charles; Lainey, Valery; de Vicente, Pablo; Quick, Jonathan; Nickola, Marisa; Neidhardt, Alexander; Kronschnabl, Gerhard; Plötz, Christian; Haas, Rüdiger; Lindqvist, Michael; Orlati, Andrea; Ipatov, Alexander V; Kharinov, Mikhail A; Mikhailov, Andrey G; Lovell, Jim; McCallum, Jamie; Stevens, Jamie; Gulyaev, Sergei A; Natush, Tim; Weston, Stuart; Wang, Weihua; Xia, Bo; Yang, Wenjun; Hao, Long-Fei; Kallunki, Juha; Witasse, Olivier

    2016-01-01

    The closest ever fly-by of the Martian moon Phobos, performed by the European Space Agency's Mars Express spacecraft, gives a unique opportunity to sharpen and test the Planetary Radio Interferometry and Doppler Experiments (PRIDE) technique in the interest of studying planet - satellite systems. The aim of this work is to demonstrate a technique of providing high precision positional and Doppler measurements of planetary spacecraft using the Mars Express spacecraft. The technique will be used in the framework of Planetary Radio Interferometry and Doppler Experiments in various planetary missions, in particular in fly-by mode. We advanced a novel approach to spacecraft data processing using the techniques of Doppler and phase-referenced very long baseline interferometry spacecraft tracking. We achieved, on average, mHz precision (30 {\\mu}m/s at a 10 seconds integration time) for radial three-way Doppler estimates and sub-nanoradian precision for lateral position measurements, which in a linear measure (at a d...

  13. Photoacoustic Doppler flow measurement in optically scattering media

    Science.gov (United States)

    Fang, Hui; Maslov, Konstantin; Wang, Lihong V.

    2007-12-01

    We recently observed the photoacoustic Doppler effect from flowing small light-absorbing particles. Here, we apply the effect to measure blood-mimicking fluid flow in an optically scattering medium. The light scattering in the medium decreases the amplitude of the photoacoustic Doppler signal but does not affect either the magnitude or the directional discrimination of the photoacoustic Doppler shift. This technology may hold promise for a new Doppler method for measuring blood flow in microcirculation with high sensitivity.

  14. Acoustic micro-Doppler radar for human gait imaging.

    Science.gov (United States)

    Zhang, Zhaonian; Pouliquen, Philippe O; Waxman, Allen; Andreou, Andreas G

    2007-03-01

    A portable acoustic micro-Doppler radar system for the acquisition of human gait signatures in indoor and outdoor environments is reported. Signals from an accelerometer attached to the leg support the identification of the components in the measured micro-Doppler signature. The acoustic micro-Doppler system described in this paper is simpler and offers advantages over the widely used electromagnetic wave micro-Doppler radars.

  15. Photoacoustic Doppler effect from flowing small light-absorbing particles.

    Science.gov (United States)

    Fang, Hui; Maslov, Konstantin; Wang, Lihong V

    2007-11-01

    From the flow of a suspension of micrometer-scale carbon particles, the photoacoustic Doppler shift is observed. As predicted theoretically, the observed Doppler shift equals half of that in Doppler ultrasound and does not depend on the direction of laser illumination. This new physical phenomenon provides a basis for developing photoacoustic Doppler flowmetry, which can potentially be used for detecting fluid flow in optically scattering media and especially low-speed blood flow of relatively deep microcirculation in biological tissue.

  16. Tissue Doppler imaging reproducibility during exercise.

    Science.gov (United States)

    Bougault, V; Nottin, S; Noltin, S; Doucende, G; Obert, P

    2008-05-01

    Tissue Doppler imaging (TDI) is an echocardiographic technique used during exercising to improve the accuracy of a cardiovascular diagnostic. The validity of TDI requires its reproducibility, which has never been challenged during moderate to maximal intensity exercising. The present study was specifically designed to assess the transmitral Doppler and pulsed TDI reproducibility in 19 healthy men, who had undergone two identical semi-supine maximal exercise tests on a cycle ergometer. Systolic (S') and diastolic (E') tissue velocities at the septal and lateral walls as well as early transmitral velocities (E) were assessed during exercise up to maximal effort. The data were compared between the two tests at 40 %, 60 %, 80 % and 100 % of maximal aerobic power. Despite upper body movements and hyperventilation, good quality echocardiographic images were obtained in each case. Regardless of exercise intensity, no differences were noticed between the two tests for all measurements. The variation coefficients for Doppler variables ranged from 3 % to 9 % over the transition from rest to maximal exercise. The random measurement error was, on average, 5.8 cm/s for E' and 4.4 cm/s for S'. Overall, the reproducibility of TDI was acceptable. Tissue Doppler imaging can be used to accurately evaluate LV diastolic and/or systolic function for this range of exercise intensity.

  17. Doppler-ultralydundersøgelse af underekstremitetsarteriosklerose

    DEFF Research Database (Denmark)

    Rørdam, P; von Jessen, F; Sillesen, H H;

    1992-01-01

    Arteriography, which requires resources and is not entirely without risk, has hitherto been a prerequisite for reconstructive surgery in cases of symptom-producing arteriosclerosis in the lower limbs. As an alternative, indirect Doppler ultrasonic examination has been employed but does not appear...

  18. Power Doppler sonography of cervical lymphadenopathy

    Energy Technology Data Exchange (ETDEWEB)

    Ahuja, Anil; Ying, Michael; Yuen, Yuen Hok; Metreweli, Constantine

    2001-12-01

    AIMS: The supraclavicular region is a common site for tuberculous and metastatic nodes from infraclavicular carcinomas. Grey scale sonographic features differentiating the two have been previously described. However, as power Doppler sonography is now frequently used in the assessment of neck nodes, power Doppler features that may help to differentiate the two are discussed. MATERIALS AND METHODS: In 78 patients, power Doppler sonograms of nodes involved by metastases from infraclavicular carcinomas (n = 24) and tuberculosis (n = 54) were evaluated. The intranodal distribution of vessels and the intranodal vascular resistance of vessels was assessed and compared. In addition, the power Doppler features of metastatic nodes from infraclavicular carcinomas were compared with metastatic nodes from a head and neck primary (n = 38) such as nasopharyngeal carcinoma (NPC). RESULTS: Tuberculous nodes frequently demonstrated displaced hilar vascularity or avascularity and the intranodal vascular resistance was low. Metastatic nodes from infraclavicular primaries demonstrated capsular or mixed vascularity and their intranodal resistance was significantly (P < 0.05) higher. In general, metastatic nodes from infraclavicular primaries had a higher intranodal vascular resistance compared to metastatic nodes from NPC, but this was not statistically significant. CONCLUSION: In the supraclavicular region, the presence of displaced low resistance hilar vascularity or avascularity in nodes is suggestive of tuberculous nodes. Metastatic nodes from infraclavicular primaries have a capsular or mixed vascularity with high resistance. Ahuja, A. et al. (2001)

  19. Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage

    DEFF Research Database (Denmark)

    Staalsø, J M; Edsen, T; Romner, B

    2013-01-01

    -coded transcranial Doppler (TCCD), with the secondary aim of describing prediction of angiographic vasospasm and mortality. METHODS: /st>Sixty patients and 70 healthy controls were each examined in duplicate by alternating operators. A total of 939 measurements divided on 201 examination sets were conducted by four...

  20. Investigations of Near-Zone Doppler Effects.

    Science.gov (United States)

    Prouty, Dale Austen

    Far away from an electromagnetic source the normal Doppler shifts in frequency occur--a red shift for receding and a blue shift for approaching. As indicated by previous work with an infinitesimal dipole, different frequency shifts occur when the source and observer move closer together, into the near-zone. These "near-zone Doppler effects" are investigated for general sources and subsequently two specific examples are presented. The general results show that near-zone shifts are similar to far-zone shifts, but the local phase velocity must be used, i.e. (DIAGRAM, TABLE OR GRAPHIC OMITTED...PLEASE SEE DAI). In the far zone the phase velocity is the speed of light; in the near zone it differs. Fundamentally, the distance between surfaces of constant phase in the near zone is changed. The surfaces of constant phase for the waves are no longer spherical, but more ellipsoidal or spheroidal, so that a moving observer sees a different frequency shift. Two specific examples are presented to indicate the actual magnitude of near-zone effects. The examples include a prolate spheroidal antenna and a circular aperture. Once the magnitude of the effects is determined, the measurability of near-zone Doppler effects is discussed. The investigation concentrates on Fresnel zone effects due to the measurement problem. Finally, it is shown that for an electrically large wire antenna (the spheroidal example) near-zone Doppler effects are measurable.

  1. Spectroscopic observation of the rotational Doppler effect.

    Science.gov (United States)

    Barreiro, S; Tabosa, J W R; Failache, H; Lezama, A

    2006-09-15

    We report on the first spectroscopic observation of the rotational Doppler shift associated with light beams carrying orbital angular momentum. The effect is evidenced as the broadening of a Hanle electromagnetically induced transparency coherence resonance on Rb vapor when the two incident Laguerre-Gaussian laser beams have opposite topological charges. The observations closely agree with theoretical predictions.

  2. Method for Canceling Ionospheric Doppler Effect

    Science.gov (United States)

    Vessot, R. F. C.

    1982-01-01

    Unified transponder system with hydrogen-maser oscillators at both stations can compensate for both motional and ionospheric components of Doppler shift. Appropriate choices of frequency shift in output of mixer m3. System exploits proportionality between dispersive component of frequency shift and reciprocal of frequency to achieve cancellation of dispersive component at output.

  3. Calculating "g" from Acoustic Doppler Data

    Science.gov (United States)

    Torres, Sebastian; Gonzalez-Espada, Wilson J.

    2006-01-01

    Traditionally, the Doppler effect for sound is introduced in high school and college physics courses. Students calculate the perceived frequency for several scenarios relating a stationary or moving observer and a stationary or moving sound source. These calculations assume a constant velocity of the observer and/or source. Although seldom…

  4. [Phlegmasia alba dolens diagnosed with Doppler ultrasonography].

    Science.gov (United States)

    Wulff, C; Lorentzen, T; Christensen, E; Pedersen, E B

    1996-11-11

    Differential diagnostic problems may occur in a patient with a cold, pale and swollen leg. Especially when the peripheral blood pressure is reduced, it is particularly difficult to distinguish cases caused by venous thrombosis from those caused by arterial embolism. Colour-Doppler ultra-sonography might be helpful for establishing the correct diagnosis. A case history is presented.

  5. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  6. On acceleration dependence of Doppler effect in light

    Indian Academy of Sciences (India)

    Sanjay M Wagh

    2013-09-01

    Using only the geometric relationships of suitable locations, we analyse Doppler effect in light to show how the acceleration of the source also contributes to the Doppler shift. We further propose that an experiment be performed using cyclotron-type devices to determine the acceleration dependence of the Doppler shift.

  7. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  8. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    guidelines and recommendations are based on personal experience since no evidence in literature exists. The basic technical background of Doppler ultrasound and typical artefacts will be discussed, in order to understand and interpret the Doppler result. Recommendations for the Doppler settings are given...

  9. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended...

  10. Solid breast neoplasms: Differential diagnosis with pulsed Doppler ultrasound

    NARCIS (Netherlands)

    T.J.A. Kuijpers (T. J A); A.I.M. Obdeijn (Inge-Marie); Ph.M. Kruyt (Philip); M. Oudkerk (Matthijs)

    1994-01-01

    textabstractIn this prospective study, duplex Doppler ultrasound was used in 95 consecutive patients with solid breast masses to evaluate the presence of neovascular flow. A positive Doppler signal, i.e., a Doppler shift frequency of more than 1 kHz using a 5 MHz insonating frequency, was found in 3

  11. Solar tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Okandan, Murat; Nielson, Gregory N.

    2016-07-12

    Solar tracking systems, as well as methods of using such solar tracking systems, are disclosed. More particularly, embodiments of the solar tracking systems include lateral supports horizontally positioned between uprights to support photovoltaic modules. The lateral supports may be raised and lowered along the uprights or translated to cause the photovoltaic modules to track the moving sun.

  12. Rubidium atomic line filtered (RALF) Doppler velocimetry

    Science.gov (United States)

    Fajardo, Mario E.; Molek, Christopher D.; Vesely, Annamaria L.

    2017-01-01

    We report recent improvements to our Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus [M.E. Fajardo, C.D. Molek, and A.L. Vesely, J. Appl. Phys. 118, 144901 (2015)]. RALF is a high-velocity and high-acceleration adaptation of the Doppler Global Velocimetry method for measuring multi-dimensional velocity vector flow fields, which was developed in the 1990s by aerodynamics researchers [H. Komine, U.S. Patent #4,919,536]. Laser velocimetry techniques in common use within the shock physics community (e.g. VISAR, Fabry-Pérot, PDV) decode the Doppler shift of light reflected from a moving surface via interference phenomena. In contrast, RALF employs a completely different physical principle: the frequency-dependent near-resonant optical transmission of a Rb/N2 gas cell, to encode the Doppler shift of reflected λ0 ≈ 780.24 nm light directly onto the transmitted light intensity. Thus, RALF is insensitive to minor changes to the optical pathlengths and transit times of the Doppler shifted light, which promises a number of practical advantages in imaging velocimetry applications. The single-point RALF proof-of-concept apparatus described here is fiber optic based, and our most recent modifications include the incorporation of a larger bandwidth detection system, and a second 780 nm laser for simultaneous upshifted-PDV (UPDV) measurements. We report results for the laser driven launch of a 10-μm-thick aluminum flyer which show good agreement between the RALF and UPDV velocity profiles, within the limitations of the admittedly poor signal:noise ratio (SNR) RALF data.

  13. A MAGNETIC CALIBRATION OF PHOTOSPHERIC DOPPLER VELOCITIES

    Energy Technology Data Exchange (ETDEWEB)

    Welsch, Brian T.; Fisher, George H. [Space Sciences Laboratory, University of California, Berkeley, CA 94720-7450 (United States); Sun, Xudong [W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305 (United States)

    2013-03-10

    The zero point of measured photospheric Doppler shifts is uncertain for at least two reasons: instrumental variations (from, e.g., thermal drifts); and the convective blueshift, a known correlation between intensity and upflows. Accurate knowledge of the zero point is, however, useful for (1) improving estimates of the Poynting flux of magnetic energy across the photosphere, and (2) constraining processes underlying flux cancellation, the mutual apparent loss of magnetic flux in closely spaced, opposite-polarity magnetogram features. We present a method to absolutely calibrate line-of-sight (LOS) velocities in solar active regions (ARs) near disk center using three successive vector magnetograms and one Dopplergram coincident with the central magnetogram. It exploits the fact that Doppler shifts measured along polarity inversion lines (PILs) of the LOS magnetic field determine one component of the velocity perpendicular to the magnetic field, and optimizes consistency between changes in LOS flux near PILs and the transport of transverse magnetic flux by LOS velocities, assuming that ideal electric fields govern the magnetic evolution. Previous calibrations fitted the center-to-limb variation of Doppler velocities, but this approach cannot, by itself, account for residual convective shifts at the limb. We apply our method to vector magnetograms of AR 11158, observed by the Helioseismic and Magnetic Imager aboard the Solar Dynamics Observatory, and find clear evidence of offsets in the Doppler zero point in the range of 50-550 m s{sup -1}. In addition, we note that a simpler calibration can be determined from an LOS magnetogram and Dopplergram pair from the median Doppler velocity among all near-disk-center PIL pixels. We briefly discuss shortcomings in our initial implementation, and suggest ways to address these. In addition, as a step in our data reduction, we discuss the use of temporal continuity in the transverse magnetic field direction to correct apparently

  14. Effect of wind turbine micro-Doppler on SAR and GMTI signatures

    Science.gov (United States)

    Bhalla, Rajan; Ling, Hao

    2014-05-01

    In this paper, we present the results of a modeling study to examine the interference effect of microDopplers caused by offshore wind farms on airborne sensors operating in the synthetic aperture radar (SAR) and ground moving target indicator (GMTI) modes. The modeling is carried out by generating CAD instantiations of the dynamic wind turbine and using the high-frequency electromagnetic code Xpatch to perform the scattering calculations. Artifacts in the resulting SAR and GMTI signatures are evaluated for interference with tracking of boats in coastal waters. Results of signal filtering algorithms to reduce the dynamic turbine clutter in both SAR images and GMTI displays are presented.

  15. Design and Performance Evaluation of a Dual Antenna Joint Carrier Tracking Loop

    Directory of Open Access Journals (Sweden)

    Wenfei Guo

    2015-10-01

    Full Text Available In order to track the carrier phases of Global Navigation Satellite Systems (GNSS signals in signal degraded environments, a dual antenna joint carrier tracking loop is proposed and evaluated. This proposed tracking loop processes inputs from two antennas, namely the master antenna and the slave antenna. The master antenna captures signals in open-sky environments, while the slave antenna capture signals in degraded environments. In this architecture, a Phase Lock Loop (PLL is adopted as a master loop to track the carrier phase of the open-sky signals. The Doppler frequency estimated by this master loop is utilized to assist weak carrier tracking in the slave loop. As both antennas experience similar signal dynamics due to satellite motion and clock frequency variations, a much narrower loop bandwidth and possibly a longer coherent integration can be adopted to track the weak signals in slave channels, by utilizing the Doppler aid from master channels. PLL tracking performance is affected by the satellite/user dynamics, clock instability, and thermal noise. In this paper, their impacts on the proposed phase tracking loop are analyzed and verified by both simulation and field data. Theoretical analysis and experimental results show that the proposed loop structure can track degraded signals (i.e., 18 dB-Hz with a very narrow loop bandwidth (i.e., 0.5 Hz and a TCXO clock.

  16. Design and Performance Evaluation of a Dual Antenna Joint Carrier Tracking Loop.

    Science.gov (United States)

    Guo, Wenfei; Lin, Tao; Niu, Xiaoji; Shi, Chuang; Zhang, Hongping

    2015-10-01

    In order to track the carrier phases of Global Navigation Satellite Systems (GNSS) signals in signal degraded environments, a dual antenna joint carrier tracking loop is proposed and evaluated. This proposed tracking loop processes inputs from two antennas, namely the master antenna and the slave antenna. The master antenna captures signals in open-sky environments, while the slave antenna capture signals in degraded environments. In this architecture, a Phase Lock Loop (PLL) is adopted as a master loop to track the carrier phase of the open-sky signals. The Doppler frequency estimated by this master loop is utilized to assist weak carrier tracking in the slave loop. As both antennas experience similar signal dynamics due to satellite motion and clock frequency variations, a much narrower loop bandwidth and possibly a longer coherent integration can be adopted to track the weak signals in slave channels, by utilizing the Doppler aid from master channels. PLL tracking performance is affected by the satellite/user dynamics, clock instability, and thermal noise. In this paper, their impacts on the proposed phase tracking loop are analyzed and verified by both simulation and field data. Theoretical analysis and experimental results show that the proposed loop structure can track degraded signals (i.e., 18 dB-Hz) with a very narrow loop bandwidth (i.e., 0.5 Hz) and a TCXO clock.

  17. Practicability of intraoperative microvascular Doppler sonography in aneurysm surgery.

    Science.gov (United States)

    Firsching, R; Synowitz, H J; Hanebeck, J

    2000-09-01

    Inadvertent narrowing of parent or branching vessels is one major cause of unfavorable outcome from aneurysm surgery. Intraoperative micro-Doppler sonography of arterial brain vessels during surgery for cerebral aneurysms of the anterior circulation was performed in 50 patients and compared retrospectively with 50 patients, who were operated upon without micro-Doppler sonography. Intraoperative micro-Doppler sonography demonstrated the need for repositioning of the clip in 12 instances. Outcome after surgery with micro-Doppler sonography appeared slightly better than without. Micro-Doppler sonography is concluded to be a practicable adjunct to routine aneurysm surgery.

  18. Exact classical Doppler effect derived from the photon emission process

    CERN Document Server

    Lin, Chyi-Lung; Hsieh, Shang-Lin; Tsai, Chun-Ming

    2016-01-01

    The concept of photon is not necessary only applied to the relativistic Doppler theory. It may also work well for classical theory. As conservation of momentum and energy are physical laws, if applying these laws gives the exact relativistic Doppler effect, it should also give the exact classical Doppler effect. So far the classical Doppler effect is only obtained by using some approximation, as derived by Fermi in 1932. We show that the exact classical Doppler effect can be derived from the photon emission process in the exact treatment and reveal that these results are the same as those derived from the wave theory of light.

  19. ESTIMATION OF DOPPLER CENTROID FREQUENCY IN SPACEBORNE SCANSAR

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Doppler centroid frequency is an essential parameter in the imaging processing of the Scanning mode Synthetic Aperture Radar(ScanSAR).Inaccurate Doppler centroid frequency will result in ghost images in imaging result.In this letter,the principle and algorithms of Doppler centroid frequency estimation are introduced.Then the echo data of ScanSAR system is analyzed.Based on the algorithms of energy balancing and correlation Doppler estimator in the estimation of Doppler centroid fequency in strip mode SAR,an improved method for Doppler centroid frequency estimation in ScanSAR is proposed.The method has improved the accuracy of Doppler centroid fequency estimation in ScanSAR by zero padding between burst data.Finally,the proposed method is validated with the processing of ENVironment SATellite Advanced Synthetic Aperture Radar(ENVISAT ASAR)wide swath raw data.

  20. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  1. Superharmonic microbubble Doppler effect in ultrasound therapy

    Science.gov (United States)

    Pouliopoulos, Antonios N.; Choi, James J.

    2016-08-01

    The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5  ×  104-5  ×  107 microbubbles ml-1) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s-1, prior to the onset of

  2. Short-Term Wind Power Forecasts using Doppler Lidar

    Science.gov (United States)

    Magerman, Beth

    With a ground-based Doppler lidar on the upwind side of a wind farm in the Tehachapi Pass of California, radial wind velocity measurements were collected for repeating sector sweeps, scanning up to 10 kilometers away. This region consisted of complex terrain, with the scans made between mountains. The dataset was utilized for techniques being studied for short-term forecasting of wind power by correlating changes in energy content and of turbulence intensity by tracking spatial variance, in the wind ahead of a wind farm. A ramp event was also captured and its propagation was tracked. Orthogonal horizontal wind vectors were retrieved from the radial velocity using a sector Velocity Azimuth Display method. Streamlines were plotted to determine the potential sites for a correlation of upstream wind speed with wind speed at downstream locations near the wind farm. A "virtual wind turbine" was "placed" in locations along the streamline by using the time-series velocity data at the location as the input to a modeled wind turbine, to determine the extractable energy content at that location. The relationship between this time-dependent energy content upstream and near the wind farm was studied. By correlating the energy content with each upstream location based on a time shift estimated according to advection at the mean wind speed, several fits were evaluated. A prediction of the downstream energy content was produced by shifting the power output in time and applying the best-fit function. This method made predictions of the power near the wind farm several minutes in advance. Predictions were also made up to an hour in advance for a large ramp event. The Magnitude Absolute Error and Standard Deviation are presented for the predictions based on each selected upstream location.

  3. Photonic Doppler velocimetry of laser-ablated ultrathin metals.

    Science.gov (United States)

    Valenzuela, A R; Rodriguez, G; Clarke, S A; Thomas, K A

    2007-01-01

    Obtaining velocity information from the interaction of a laser pulse on a metal layer provides insight into the rapid dynamics of material removal and plasma plume physics during ablation. A traditional approach involves using a velocity interferometer system for any reflector (VISAR) on a reflective metal surface. However, when the target is a thin metal layer, the cohesion of the surface is quickly lost resulting in a large spread of particle velocities that cannot be easily resolved by VISAR. This is due to material ejection"confusing" the VISAR measurement surface, effectively washing out the spatial fringe visibility in the VISAR interferometer. A new heterodyne-based optical velocimeter method is the photonic Doppler velocimeter (PDV). Because PDV tracks motion in a frequency encoded temporal electro-optical signal, velocity information is preserved and allows for multiple velocity components to be recorded simultaneously. The challenge lies in extracting PDV velocity information at short (nanosecond) laser ablation time scales with rapidly varying heterodyne beats by using electronic, optical, and analytical techniques to recover the velocity information from a fleeting signal. Here we show how we have been able to obtain velocity information on the nanosecond time scale and are able to compare it to hydrodynamic simulations. Also, we examine refinements to our PDV system by increasing the bandwidth, utilizing different probes, and sampling different analysis techniques.

  4. River Bed Sediment Classification Using Acoustic Doppler Profiler

    Science.gov (United States)

    Shields, F. D.

    2008-12-01

    Restoration or rehabilitation of degraded stream and river habitats requires definition of a target condition and preferably post-implementation monitoring to gage progress toward the target. Stream habitat has been characterized by computing statistics based on measurements of water depth and velocity at each point of a horizontal grid. In many cases stream bed type and cover, both qualitatively assessed, were included as additional grid variables. Resultant statistics describing the central tendency, variability and spatial distribution of these three or four variables and their combinations have been used to explain key differences between more- and less-degraded streams and to infer biotic responses. Usually the required data are collected by wading observers, but application to larger rivers is problematic. Collection of water depth and velocity information may be automated across a wide range of stream sizes using an acoustic Doppler profiler (aDp). Herein we suggest that aDp data may also be used to infer bed hardness and thus type by extracting the return signal strength from the bottom track signal and using this information to compute the echo intensity at the bed. A method for computing echo intensity, along with key assumptions is presented. Echo intensity is computed for a range of river environments and related to the size and related characteristics of bed material. Habitat maps for river reaches depicting water depth, velocity and bed type developed from aDp data sets are presented.

  5. Transcranial power M-mode Doppler ultrasound for diagnosis of patent foramen ovale

    Science.gov (United States)

    Moehring, Mark; Spencer, Merrill

    2005-04-01

    Patent foramen ovale (PFO) is a right-to-left shunt (RLS) which communicates blood from the right to left atrium of the heart. PFO has been associated with stroke and, more recently, with migraine headache. Diagnosis of RLS can be accomplished effectively with transcranial power M-mode Doppler ultrasound (PMD). PMD is a modality which can be performed without the sedation required by the more invasive diagnostic technique using transesophageal echocardiography. PMD for this application consists of 2 MHz pulse Doppler ultrasound with placement of sample gates at 2 mm intervals along the single-transducer beam axis, and 8 kHz pulse repetition rate (PMD100M, Spencer Technologies). Doppler power versus depth is constructed every 4ms, using 33 sample gates. Bubble microemboli injected in the venous system and moving across a PFO present as high intensity tracks on a PMD image, as emboli transit from the heart to the brain and through the observed cerebral vasculature. Use of PMD in this context has been reported in the clinical literature [M. P. Spencer, M. A. Moehring, J. Jesurum et al, J. Neuroimaging 14, 342-349 (2004)]. This talk surveys the basic technical features of PMD for sensing PFO-related showers of bubble microemboli, and how these features provide clues to the severity of PFO.

  6. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  7. Renal duplex Doppler ultrasound findings in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1993-12-15

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  8. [Color-Doppler semiology in transplanted kidney].

    Science.gov (United States)

    Rivolta, R; Castagnone, D; Burdick, L; Mandelli, C; Mangiarotti, R

    1993-05-01

    Color-encoded duplex ultrasonography (CEDU) makes a more accurate technique in kidney graft monitoring by combining real-time US with pulsed Doppler studies of renal vasculature. It is a non-invasive and easy technique. Suitable to study the whole renal artery and vein, CEDU also allows the qualitative and quantitative assessment of the intrarenal vasculature and therefore the easy diagnosis of such vessel dysfunctions as arteriovenous fistulas following biopsy. Moreover, Doppler spectral analysis can be used to distinguish among different causes of renal allograft dysfunction--i.e. rejection, cyclosporine nephrotoxicity or acute tubular necrosis. The value of the resistive index for the differential diagnosis is discussed. CEDU allows a more reliable measurement of renal blood flow thanks to the more precise evaluation of renal artery diameter and mean flow velocity.

  9. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  10. Doppler Lidar Wind Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Newsom, R. K. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Shippert, T. R. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. D. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  11. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  12. Features of remodeling of right heart chambers according to tissue Doppler and its correlation with cardiac rhythm disturbance in patients with COPD 2-3 severity

    Directory of Open Access Journals (Sweden)

    O. A. Zhuk

    2014-01-01

    Full Text Available The article presents the study of early sings of dysfunction of right and left chambers of heart in patients with COPD 2 - 3 severity, correlation between structural and electrical remodeling of heart according to the stages of pulmonary hypertension. Standard tissue Doppler echocardiographic parameters and modes were used for the diagnosing. We examined 35 patients with COPD 2 - 3 severity; the control group consisted of 15 patients. The ECG Holter monitoring was made for all patients to identify cardiac rhythm disturbance and correlation with the COPD severity. Standard method of the ECG with modes of tissue Doppler (pulsed wave Tissue Doppler Imaging - PW TDI, color tissue Doppler imaging -TDI, tissue myocardial Doppler - TMD, tissue Tracking - TT, Doppler for evaluation of myocardial strain and myocardial strain rate were made to identify the stage of dysfunction. The results of the study concluded that according to the TDI the dysfunction of right ventricle was more apparent in patients with COPD 3 severity. Pathological arrhythmias were significantly detected in group of patients with COPD 3 severity. In compliance with our observations, the reduce of rapid myocardial strain rates and its inverse proportion with the severity in accordance to the evaluation of longitudinal strain and rate of movement of fibrous ring in tricuspid valve were observed in patients with COPD. Thus the application of the TDI modes for evaluating of early signs of cardiac remodeling in patients with COPD and potential adequate jugulation for preventing chronic cor pulmonale is expedient.

  13. Precise Doppler Monitoring of Barnard's Star

    CERN Document Server

    Choi, Jieun; Marcy, Geoffrey W; Howard, Andrew W; Fischer, Debra A; Johnson, John A; Isaacson, Howard; Wright, Jason T

    2012-01-01

    We present 248 precise Doppler measurements of Barnard's Star (Gl 699), the second nearest star system to Earth, obtained from Lick and Keck Observatories during 25 years between 1987 and 2012. The early precision was 20 \\ms{} but was 2 \\ms{} during the last 8 years, constituting the most extensive and sensitive search for Doppler signatures of planets around this stellar neighbor. We carefully analyze the 136 Keck radial velocities spanning 8 years by first applying a periodogram analysis to search for nearly circular orbits. We find no significant periodic Doppler signals with amplitudes above $\\sim$2 \\ms{}, setting firm upper limits on the minimum mass (\\msini) of any planets with orbital periods from 0.1 to 1000 days. Using a Monte Carlo analysis for circular orbits, we determine that planetary companions to Barnard's Star with masses above 2 \\mearth{} and periods below 10 days would have been detected. Planets with periods up to 2 years and masses above 10 \\mearth{} (0.03 \\mjup) are also ruled out. A sim...

  14. Doppler Lidar for Wind Measurements on Venus

    Science.gov (United States)

    Singh, Upendra N.; Emmitt, George D.; Yu, Jirong; Kavaya, Michael J.

    2010-01-01

    NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. The transmitter portion of the transceiver employs the high-pulse-energy, Ho:Tm:LuLiF, partially conductively cooled laser technology developed at NASA Langley. The transceiver is capable of 250 mJ pulses at 10 Hz. It is very similar to the technology envisioned for coherent Doppler lidar wind measurements from Earth and Mars orbit. The transceiver is coupled to the large optics and data acquisition system in the NASA Langley VALIDAR mobile trailer. The large optics consists of a 15-cm off-axis beam expanding telescope, and a full-hemispheric scanner. Vertical and horizontal vector winds are measured, as well as relative backscatter. The data acquisition system employs frequency domain velocity estimation and pulse accumulation. It permits real-time display of the processed winds and archival of all data. This lidar system was recently deployed at Howard University facility in Beltsville, Mary-land, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other sensors will be presented. A simulation and data product for wind measurement at Venus will be presented.

  15. A digital open-loop Doppler processing prototype for deep-space navigation

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    A prototype based on digital radio technology with associated open-loop Doppler signal processing techniques has been developed to measure a spacecraft’s line-of-sight velocity. The prototype was tested in China’s Chang’E-1 lunar mission relying on S-band telemetry signals transmitted by the sat-ellite,with results showing that the residuals had a RMS value of ~3 mm/s (1σ ) using 1-sec integration,which is consistent with the Chinese conventional USB (Unified S-Band) tracking system. Such preci-sion is mainly limited by the short-term stability of the atomic (e.g. rubidium) clock at the uplink ground station. It can also be improved with proper calibration to remove some effects of the transmission media (such as solar plasma,troposphere and ionosphere),and a longer integration time (e.g. down to 0.56 mm/s at 34 seconds) allowed by the spacecraft dynamics. The tracking accuracy can also be in-creased with differential methods that may effectively remove most of the long-term drifts and some of the short-term uncertainties of the uplink atomic clock,thereby further reducing the residuals to the 1 mm/s level. Our experimental tracking data have been used in orbit determination for Chang’E-1,while other applications (such as the upcoming YH-1 Mars orbiter) based on open-loop Doppler tracking will be initiated in the future. Successful application of the prototype to the Chang’E-1 mission in 2008 is believed to have great significance for China’s future deep space exploration.

  16. A digital open-loop Doppler processing prototype for deep-space navigation

    Institute of Scientific and Technical Information of China (English)

    JIAN NianChuan; QIU Shi; FUNG Lai-Wo; ZHANG Hua; WANG Zhen; GOU Wei; SHANG Kun; ZHANG SuJun; WANG MingYuan; SHI Xian; PING JingSong; YAN JianGuo; TANG GeShi; LIU JunZe

    2009-01-01

    A prototype based on digital radio technology with associated open-loop Doppler signal processing techniques has been developed to measure a spacecraft's line-of-sight velocity. The prototype was tested in China's Chang'E-1 lunar mission relying on S-band telemetry signals transmitted by the satellite, with results showing that the residuals had a RMS value of ~3 mm/s (1 σ ) using 1-sec integration, which is consistent with the Chinese conventional USB (Unified S-Band) tracking system. Such precision is mainly limited by the short-term stability of the atomic (e.g. Rubidium) clock at the uplink ground station. It can also be improved with proper calibration to remove some effects of the transmission media (such as solar plasma, troposphere and ionosphere), and a longer integration time (e.g. Down to 0.56 mm/s at 34 seconds) allowed by the spacecraft dynamics. The tracking accuracy can also be increased with differential methods that may effectively remove most of the long-term drifts and some of the short-term uncertainties of the uplink atomic clock, thereby further reducing the residuals to the 1 mm/s level. Our experimental tracking data have been used in orbit determination for Chang'E-1, while other applications (such as the upcoming YH-1 Mars orbiter) based on open-loop Doppler tracking will be initiated in the future. Successful application of the prototype to the Chang'E-1 mission in 2008 is believed to have great significance for China's future deep space exploration.

  17. Renewable Energy Tracking Systems

    Science.gov (United States)

    Renewable energy generation ownership can be accounted through tracking systems. Tracking systems are highly automated, contain specific information about each MWh, and are accessible over the internet to market participants.

  18. Forward tracking detectors

    Indian Academy of Sciences (India)

    Klaus Mönig

    2007-11-01

    Forward tracking is an essential part of a detector at the international linear collider (ILC). The requirements for forward tracking are explained and the proposed solutions in the detector concepts are shown.

  19. Performance of ATLAS tracking

    CERN Document Server

    Roe, Shaun; The ATLAS collaboration

    2017-01-01

    Run-2 of the Large Hadron Collider (LHC) has provided new challenges to track and vertex reconstruction with higher centre-of-mass energies and luminosity leading to increasingly high-multiplicity envi-ronments. This talk provides an overview of the tracking performance, highlighting tracking improvements due to the Insertable B-Layer (IBL) and the introduction of time-dependent alignment.

  20. Beam Footprint Detection and Tracking for Non-cooperative Bistatic SAR

    Directory of Open Access Journals (Sweden)

    F. Yan

    2016-09-01

    Full Text Available In non-cooperative bistatic synthetic aperture radar (SAR, the position of transmitter’s beam footprint should be detected and tracked in real-time to perform beam synchronization. Theoretical analysis shows that signal-to-noise ratio (SNR of the reflected echoes from the observational scene is too low to apply the conventional detection and tracking method. According to the cross correlation and Doppler frequency information of the backscattering echo, a beam footprint detection and tracking method is proposed in this paper. This method can realize accumulation of signal energy, therefore enormously improve the performance of beam footprint detection and tracking. Meanwhile, vehicle-based bistatic SAR experiment and airborne bistatic SAR experiment are performed to evaluate the performance of the proposed beam footprint detection and tracking method. Experimental results show that the proposed method performs well for real-time transmitter beam footprint detection and tracking.

  1. Doppler effect in resonant photoemission from SF6: correlation between Doppler profile and Auger emission anisotropy.

    Science.gov (United States)

    Kitajima, M; Ueda, K; De Fanis, A; Furuta, T; Shindo, H; Tanaka, H; Okada, K; Feifel, R; Sorensen, S L; Gel'mukhanov, F; Baev, A; Agren, H

    2003-11-21

    Fragmentation of the SF6 molecule upon F 1s excitation has been studied by resonant photoemission. The F atomiclike Auger line exhibits the characteristic Doppler profile that depends on the direction of the photoelectron momentum relative to the polarization vector of the radiation as well as on the photon energy. The measured Doppler profiles are analyzed by the model simulation that takes account of the anisotropy of the Auger emission in the molecular frame. The Auger anisotropy extracted from the data decreases with an increase in the F-SF5 internuclear distance.

  2. Track finding efficiency in

    Energy Technology Data Exchange (ETDEWEB)

    Allmendinger, T.; Bhuyan, B.; Brown, D. N.; Choi, H.; Christ, S.; Covarelli, R.; Davier, M.; Denig, A. G.; Fritsch, M.; Hafner, A.; Kowalewski, R.; Long, O.; Lutz, A. M.; Martinelli, M.; Muller, D. R.; Nugent, I. M.; Lopes Pegna, D.; Purohit, M. V.; Prencipe, E.; Roney, J. M.; Simi, G.; Solodov, E. P.; Telnov, A. V.; Varnes, E.; Waldi, R.; Wang, W. F.; White, R. M.

    2012-12-10

    We describe several studies to measure the charged track reconstruction efficiency and asymmetry of the BaBar detector. The first two studies measure the tracking efficiency of a charged particle using τ and initial state radiation decays. The third uses the τ decays to study the asymmetry in tracking, the fourth measures the tracking efficiency for low momentum tracks, and the last measures the reconstruction efficiency of K$0\\atop{S}$ particles. The first section also examines the stability of the measurements vs. BaBar running periods.

  3. Telecommunication systems engineering. [Book on tracking, command, telemetry, data acquisition

    Science.gov (United States)

    Lindsey, W. C.; Simon, M. K.

    1973-01-01

    Telecommunication network concepts are discussed together with carrier-tracking loops employing the phase-lock principle, phase and Doppler measurements in two-way phase-coherent tracking systems, range measurements by phase-coherent techniques, and questions of phase-coherent detection with perfect reference signals and with noisy reference signals. The design of one-way and two-way phase-coherent communication systems is considered, giving attention to the optimal design of single-channel systems, the design of two-channel systems, and the design of multichannel systems. Other topics explored include the design and the performance of phase-coherent systems preceded by band-pass limiters, symbol synchronization and its effects on data detection, noncoherent communication over the Gaussian channel, and tracking loops with improved performance.

  4. Doppler-compensated three-photon electromagnetically induced transparency

    CERN Document Server

    Carr, Christopher; Sargsyan, Armen; Sarkisyan, David; Adams, Charles S; Weatherill, Kevin J

    2012-01-01

    We demonstrate Doppler-compensated bright and dark states in a resonant four-level atomic system. The spectral features are the result of electromagnetically induced transparency (EIT) and absorption (EIA) and are sub-Doppler due to the compensation of Doppler shifts with AC Stark shifts. We demonstrate the effect using a three-photon cascade system to Rydberg states in Cs vapor, however, the results apply to any four-level cascade or N-type system.

  5. Influence of Doppler Bin Width on GNSS Detection Probabilities

    CERN Document Server

    Geiger, Bernhard C

    2011-01-01

    The acquisition stage in GNSS receivers determines Doppler shifts and code phases of visible satellites. Acquisition is thus a search in two continuous dimensions, where the digital algorithms require a partitioning of the search space into cells. We present analytic expressions for the acquisition performance depending on the partitioning of the Doppler frequency domain. In particular, the impact of the number and width of Doppler bins is analyzed. The presented results are verified by simulations.

  6. New insights from inside-out Doppler tomography

    CERN Document Server

    Kotze, Enrico J

    2015-01-01

    We present preliminary results from our investigation into using an 'inside-out' velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  7. Analysis on rotational Doppler Effect based on modal expansion method

    CERN Document Server

    Zhou, Hailong; Zhang, Pei; Zhang, Xinliang

    2015-01-01

    We theoretically investigate the optical rotational Doppler Effect using modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the change of mode index. The theoretical model makes us better understand the physical processes of rotational Doppler Effect. It can provide theoretical guidance for many related applications, such as detection of rotating bodies, detection of OAM and frequency shift.

  8. Range-instantaneous Doppler imaging of inverse synthetic aperture sonar

    Institute of Scientific and Technical Information of China (English)

    XU Jia; JIANG Xingzhou; TANG Jingsong

    2003-01-01

    Because the existing range-Doppler algorithm in inverse synthetic aperture sonar (ISAS) is based on target model of uniform motion, it may be invalidated for maneuvering targets due to the time-varying changes of both individual scatter′s Doppler and imaging projection plane. To resolve the problem, a new range-instantaneous Doppler imaging method is proposed for imaging maneuvering targets based on time-frequency analysis. The proposed approach is verified using real underwater acoustic data.

  9. Advanced Tracking of Vehicles

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Li, K.-J.; Pakalnis, Stardas

    2005-01-01

    With the continued advances in wireless communications, geo-location technologies, and consumer electronics, it is becoming possible to accurately track the time-varying location of each vehicle in a population of vehicles. This paper reports on ongoing research that has as it objective to develop...... efficient tracking techniques. More specifically, while almost all commercially available tracking solutions simply offer time-based sampling of positions, this paper's techniques aim to offer a guaranteed tracking accuracy for each vehicle at the lowest possible costs, in terms of network traffic...... and server-side updates. This is achieved by designing, prototyping, and testing novel tracking techniques that exploit knowledge of the road network and past movement. These resulting tracking techniques are to support mobile services that rely on the existence of a central server that continuously tracks...

  10. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  11. EUV Doppler Imaging for CubeSat Platforms Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Mature the design and fabricate the Flare Initiation Doppler Imager (FIDI) instrument to demonstrate low-spacecraft-resource EUV technology (most notably,...

  12. Reexamination of the Doppler effect through Maxwell's equations.

    Science.gov (United States)

    Guo, Wei; Aktas, Yildirim

    2012-08-01

    In this work, the electric field emitted from a moving source, an electric point dipole, is analyzed for the purpose of illustrating the physics behind the Doppler effect. It is found that if the (translational) motion of the source is nonrelativistic, the Doppler effect is realized in two steps: the motion of the source first causes the dyadic Green function associated with the electric field to acquire an oscillation frequency in the far-field region of the source, and then the frequency leads to the Doppler effect. It is also demonstrated that the Doppler effect is observable only in the far-field region of the source.

  13. Tracks: Nurses and the Tracking Network

    Centers for Disease Control (CDC) Podcasts

    2012-06-06

    This podcast highlights the utility of the National Environmental Public Health Tracking Network for nurses in a variety of work settings. It features commentary from the American Nurses Association and includes stories from a public health nurse in Massachusetts.  Created: 6/6/2012 by National Center for Environmental Health (NCEH)/Division of Environmental Hazards and Health Effects (DEHHE)/Environmental Health Tracking Branch (EHTB).   Date Released: 6/6/2012.

  14. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  15. Acoustic Doppler current profiling from the JGOFS Arabian Sea cruises aboard the RV T.G. Thompson

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.S.; Flagg, C.N.; Shi, Y. [Brookhaven National Lab., Upton, NY (United States). Oceanographic and Atmospheric Sciences Div.

    1996-12-01

    Acoustic Doppler current profiler (ADCP) data is part of the core data for the US JGOFS Arabian Sea project, along with hydrographic and nutrient data. Seventeen cruises are scheduled to take place between September 1994 and January 1996 on the R/V T.G. Thompson. Seven of the cruises follow a standard cruise track, taking hydrographic, chemical and biological measurements. The rest of the cruises, which take place generally within the standard cruise region defined by a set track, are for the deployment and recovery of moored equipment and towing of a SeaSoar. Detailed description of ADCP hardware, the AutoADCP data acquisition system, and the collection of navigation and compass data on the Thompson is documented in Section 2. Followed by data collection for each cruise together with a cruise track, Section 3 presents the processing and analysis of velocity and acoustic backscatter intensity data. Section 5 shows results of profile quality diagnosis.

  16. Applications of Doppler optical coherence tomography

    Science.gov (United States)

    Xu, Zhiqiang

    A major development in biomedical imaging in the last decade has been optical coherence tomography (OCT). This technique enables microscale resolution, depth resolved imaging of the detailed morphology of transparent and nontransparent biological tissue in a noncontact and quasi-noninvasive way. In the first part of this dissertation, we will describe the development and the performance of our home-made OCT systems working with different wavelength regions based on free-space and optical fiber Michelson interferometers. The second part will focus on Doppler OCT (DOCT), an important extension of OCT, which enables the simultaneous evaluation of the structural information and of the fluid flow distribution at a localized position beneath the sample surface. Much effort has been spent during the past few years in our laboratory aimed at providing more accurate velocity measurements with an extended dynamic range. We also applied our technique in different research areas such as microfluidics and hemodynamics. Investigations on the optical properties of the biological tissues (such as absorption and scattering) corresponding to different center wavelengths, have been performed in our laboratory. We used a 10 femtosecond Ti:sapphire laser centered at about 810 nm associated with a free-space Michelson interferometer. The infrared sources were centered at about 1310 and 1560 nm with all-fiber interferometers. Comparative studies using three different sources for several in vitro biological tissues based on a graphical method illustrated how the optical properties affect the quality of the OCT images in terms of the penetration depth and backscattering intensity. We have shown the advantage of working with 810-nm emission wavelength for good backscattering amplitude and contrast, while sources emitting at 1570 nm give good penetration depth. The 1330-nm sources provide a good compromise between the two. Therefore, the choice of the source will ultimately determine the

  17. [Color Doppler sonography of focal abdominal lesions].

    Science.gov (United States)

    Licanin, Zoran; Lincender, Lidija; Djurović, V; Salihefendić, Nizama; Smajlović, Fahrudin

    2004-01-01

    Color Doppler sonography (CDS--spectral, color and power), harmonic imaging techniques (THI, PHI), possibility of 3D analysis of picture, usage of contrast agents, have raised the values of ultrasound as a diagnostic method to a very high level. THI--non-linear gray scale modality, is based on the processing of higher reflected frequencies, that has improved a picture resolution, which is presented with less artifacts and limiting effects of obesity and gases. Ultrasound contrast agents improve analysis of micro and macro circulation of the examined area, and with the assessment of velocity of supply in ROI (wash in), distribution and time of signal weakening (wash out), are significantly increasing diagnostic value of ultrasound. Besides the anatomical and topographic presentation of examined region (color, power), Color Doppler sonography gives us haemodynamic-functional information on vascularisation of that region, as well as on pathologic vascularisation if present. Avascular aspect of a focal pathologic lesion corresponds to a cyst or haematoma, while coloration and positive spectral curve discover that anechogenic lesions actually represents aneurysms, pseudoaneurysms or AVF. In local inflammatory lesion, abscess in an acute phase, CDS shows first increased, and then decreased central perfusion, while in a chronic phase, a pericapsular vascularisation is present. Contribution of CDS in differentiation of hepatic tumors (hemangioma, HCC and metastasis) is very significant. Central color dots along the peripheral blood vessels and the blush phenomenon are characteristics of capillary hemangioma, peritumoral vascular ring "basket" of HCC, and "detour" sign of metastasis. The central artery, RI from 0.45 to 0.60 and radial spreading characterize FNH. Hepatic adenoma is characterized by an intratumoral vein, and rarely by a vascular hallo. Further on, blood velocity in tumor defined by Color Doppler, distinguishes malignant from benign lesion, where 40 cm/s is a

  18. Neutral wind results from TIMED Doppler interferometer

    Science.gov (United States)

    Killeen, T.; Gablehouse, R.; Gell, D.; Johnson, R.; Niciejewski, R.; Ortland, D.; Wu, Q.; Skinner, W.; Solomon, S.; Kafkalidis, J.

    2003-04-01

    Since the launch of the NASA Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics (TIMED) satellite in December 2001, the TIMED Doppler Interferometer (TIDI) has been collecting lower thermosphere and mesospheric data for over a year. After adjustments to the spectral sampling scheme and operational mode, the instrument has been optimized. Efforts have also been made to improve the instrument performance. Preliminary neutral winds from O2 (0-0) have been analyzed. Tidal features and their seasonal variation are shown clearly in the wind data, which are quantitatively consistent with model prediction. We will report our progress on these efforts.

  19. Mobile fiber-optic laser Doppler anemometer.

    Science.gov (United States)

    Stieglmeier, M; Tropea, C

    1992-07-20

    A laser Doppler anemometer (LDA) has been developed that combines the compactness and low power consumption of laser diodes and avalanche photodiodes with the flexibility and possibility of miniaturization by using fiber-optic probes. The system has been named DFLDA for laser diode fiber LDA and is especially suited for mobile applications, for example, in trains, airplanes, or automobiles. Optimization considerations of fiber-optic probes are put forward and several probe examples are described in detail. Measurement results from three typical applications are given to illustrate the use of the DFLDA. Finally, a number of future configurations of the DFLDA concept are discussed.

  20. Check list Doppler and duplex sonography. 4. rev. ed.; Checkliste Doppler- und Duplexsonografie

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, Helmut [MED-Facharztzentrum, Mainz (Germany). Praxis fuer Gefaessmedizin; Ludwig, Malte [Benedictus Krankenhaus Tutzing (Germany). Gefaesszentrum

    2012-11-01

    Check list Doppler and duplex sonography includes 4 parts: (1) Basic information: technical fundamentals, equipment premises, hemodynamics. (2) Flow schemata and pitfalls. (3) Special vascular regions: arteries in the upper and lower extremities, veins in the upper and lower extremities, abdominal arteries, abdominal veins, ex-cranial brain sustaining arteries, intra-cranial brain sustaining arteries. (4) Attachment: diagnostic criteria and case studies.

  1. QRev—Software for computation and quality assurance of acoustic doppler current profiler moving-boat streamflow measurements—User’s manual for version 2.8

    Science.gov (United States)

    Mueller, David S.

    2016-05-12

    The software program, QRev computes the discharge from moving-boat acoustic Doppler current profiler measurements using data collected with any of the Teledyne RD Instrument or SonTek bottom tracking acoustic Doppler current profilers. The computation of discharge is independent of the manufacturer of the acoustic Doppler current profiler because QRev applies consistent algorithms independent of the data source. In addition, QRev automates filtering and quality checking of the collected data and provides feedback to the user of potential quality issues with the measurement. Various statistics and characteristics of the measurement, in addition to a simple uncertainty assessment are provided to the user to assist them in properly rating the measurement. QRev saves an extensible markup language file that can be imported into databases or electronic field notes software. The user interacts with QRev through a tablet-friendly graphical user interface. This report is the manual for version 2.8 of QRev.

  2. Doppler term in the galaxy two-point correlation function: wide-angle, velocity, Doppler lensing and cosmic acceleration effects

    OpenAIRE

    Raccanelli, Alvise; Bertacca, Daniele; Jeong, Donghui; Neyrinck, Mark C.; Szalay, Alexander S.

    2016-01-01

    We study the parity-odd part (that we shall call Doppler term) of the linear galaxy two-point correlation function that arises from wide-angle, velocity, Doppler lensing and cosmic acceleration effects. As it is important at low redshift and at large angular separations, the Doppler term is usually neglected in the current generation of galaxy surveys. For future wide-angle galaxy surveys such as Euclid, SPHEREx and SKA, however, we show that the Doppler term must be included. The effect of t...

  3. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  4. Initial Results from the XUV Doppler Telescope

    Science.gov (United States)

    Kano, R.; Hara, H.; Kobayashi, K.; Kumagai, K.; Nagata, S.; Sakao, T.; Shimizu, T.; Tsuneta, S.; Yoshida, T.

    We developed a unique telescope to obtain simultaneous XUV images and the velocity maps by measuring the line-of-sight Doppler shifts of the Fe XIV 211A&ring line (T = 1.8 MK): the Solar XUV Doppler Telescope (hereafter XDT). The telescope was launched by the Institute of Space and Astronautical Science with the 22nd S520 rocket on January 31, 1998, and took 14 XUV whole sun images during 5 minutes. Simultaneous observations of XDT with Yohkoh (SXT), SOHO (EIT, CDS, LASCO and MDI) were successfully carried out. The images taken with EIT, XDT and SXT are able to cover the wide temperature ranging from 1 to 10 MK, and clearly show the multi-temperature nature of the solar corona. Indeed, we notice that both the cool (1-2 MK) loops observed with EIT and XDT, and the hot (>3 MK) loops observed with SXT exist in the same active regions but in a spatially exclusive way. The XDT red-blue ratio between longer- and shorter-wavelength bands of Fe XIV 211A&ring line indicates a possible down-flow of 1.8 MK plasma near the footpoints of multiple cool loops

  5. A radar unattended ground sensor with micro-Doppler capabilities for false alarm reduction

    Science.gov (United States)

    Tahmoush, Dave; Silvious, Jerry; Burke, Ed

    2010-10-01

    Unattended ground sensors (UGS) provide the capability to inexpensively secure remote borders and other areas of interest. However, the presence of normal animal activity can often trigger a false alarm. Accurately detecting humans and distinguishing them from natural fauna is an important issue in security applications to reduce false alarm rates and improve the probability of detection. In particular, it is important to detect and classify people who are moving in remote locations and transmit back detections and analysis over extended periods at a low cost and with minimal maintenance. We developed and demonstrate a compact radar technology that is scalable to a variety of ultra-lightweight and low-power platforms for wide area persistent surveillance as an unattended, unmanned, and man-portable ground sensor. The radar uses micro-Doppler processing to characterize the tracks of moving targets and to then eliminate unimportant detections due to animals as well as characterize the activity of human detections. False alarms from sensors are a major liability that hinders widespread use. Incorporating rudimentary intelligence into sensors can reduce false alarms but can also result in a reduced probability of detection. Allowing an initial classification that can be updated with new observations and tracked over time provides a more robust framework for false alarm reduction at the cost of additional sensor observations. This paper explores these tradeoffs with a small radar sensor for border security. Multiple measurements were done to try to characterize the micro-Doppler of human versus animal and vehicular motion across a range of activities. Measurements were taken at the multiple sites with realistic but low levels of clutter. Animals move with a quadrupedal motion, which can be distinguished from the bipedal human motion. The micro-Doppler of a vehicle with rotating parts is also shown, along with ground truth images. Comparisons show large variations for

  6. On Not Losing Track

    OpenAIRE

    Washburn, A.R.

    1990-01-01

    IEEE Transactions on Automatic Control, Vol. 35, 1990, pp. 852-855. This paper uses tracking time as an explicit objective in designing tracking algorithms that function in clutter. Implications of using "time to the first mistake" as a measure of tracking time are explored. An optimal tracker is derived for a special circukstance where there is clutter, but no measurement error, and is compared to a tracker based on the Maximum Likelihood principle.

  7. Functional Doppler optical coherence tomography for cortical blood flow imaging

    Science.gov (United States)

    Yu, Lingfeng; Liu, Gangjun; Nguyen, Elaine; Choi, Bernard; Chen, Zhongping

    2010-02-01

    Optical methods have been widely used in basic neuroscience research to study the cerebral blood flow dynamics in order to overcome the low spatial resolution associated with magnetic resonance imaging and positron emission tomography. Although laser Doppler imaging and laser speckle imaging can map out en face cortical hemodynamics and columns, depth resolution is not available. Two-photon microscopy has been used for mapping cortical activity. However, flow measurement requires fluorescent dye injection, which can be problematic. The noninvasive and high resolution tomographic capabilities of optical coherence tomography make it a promising technique for mapping depth resolved cortical blood flow. Here, we present a functional Doppler optical coherence tomography (OCT) imaging modality for quantitative evaluation of cortical blood flow in a mouse model. Fast, repeated, Doppler OCT scans across a vessel of interest were performed to record flow dynamic information with a high temporal resolution of the cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time, thereby providing complementary temporal flow information to the spatially distributed flow information of Doppler OCT. The proposed functional Doppler OCT imaging modality can be used to diagnose vessel stenosis/blockage or monitor blood flow changes due to pharmacological agents/neuronal activities. Non-invasive in-vivo mice experiments were performed to verify the capabilities of function Doppler OCT.

  8. Measurement of depth of burns by laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Droog, E.J.; Droog, E.J.; Steenbergen, Wiendelt; Sjöberg, F.

    2001-01-01

    Laser Doppler perfusion imaging (LDPI), is a further development in laser Doppler flowmetry (LDF). Its advantage is that it enables assessment of microvascular blood flow in a predefined skin area rather than, as for LDF, in one place. In many ways this method seems to be more promising than LDF in

  9. Micro-Doppler classification of riders and riderless horses

    Science.gov (United States)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  10. A Rayleigh Doppler Frequency Estimator Derived from Maximum Likelihood Theory

    DEFF Research Database (Denmark)

    Hansen, Henrik; Affes, Sofiene; Mermelstein, Paul

    1999-01-01

    Reliable estimates of Rayleigh Doppler frequency are useful for the optimization of adaptive multiple access wireless receivers.The adaptation parameters of such receivers are sensitive to the amount of Doppler and automatic reconfiguration to the speed of terminalmovement can optimize cell...

  11. Measurement of depth of burns by laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Droog, E.J.; Steenbergen, W.; Sjöberg, F.

    2001-01-01

    Laser Doppler perfusion imaging (LDPI), is a further development in laser Doppler flowmetry (LDF). Its advantage is that it enables assessment of microvascular blood flow in a predefined skin area rather than, as for LDF, in one place. In many ways this method seems to be more promising than LDF in

  12. Compressive sensing for high resolution profiles with enhanced Doppler performance

    NARCIS (Netherlands)

    Anitori, L.; Hoogeboom, P.; Chevalier, F. Le; Otten, M.P.G.

    2012-01-01

    In this paper we demonstrate how Compressive Sensing (CS) can be used in pulse-Doppler radars to improve the Doppler performance while preserving range resolution. We investigate here two types of stepped frequency waveforms, the coherent frequency bursts and successive frequency ramps, which can be

  13. An elementary approach to the gravitational Doppler shift

    Science.gov (United States)

    Wörner, C. H.; Rojas, Roberto

    2017-01-01

    In college physics courses, treatment of the Doppler effect is usually done far from the first introduction to kinematics. This paper aims to apply a graphical treatment to describe the gravitational redshift, by considering the Doppler effect in two accelerated reference frames and exercising the equivalence principle. This approach seems appropriate to discuss with beginner students and could serve to enrich the didactic processes.

  14. Detection and visualization to Doppler sensitive sonar pulses

    NARCIS (Netherlands)

    Bertrand, D.B.; IJsselmuide, S.P. van; Beerens, S.P.

    2006-01-01

    In anti-submarine warfare, the use of Doppler sensitive sonar pulses is common practice. In particular, the wideband Doppler sensitive PTFM pulse (Pulse Train Frequency Modulation) is a powerful tool for detection in reverberation limited conditions. Nevertheless, this pulse is not operationally

  15. The value of Doppler ultrasound in cirrhosis and portal hypertension

    NARCIS (Netherlands)

    Kok, T; van der Jagt, EJ; Haagsma, EB; Bijleveld, CMA; Jansen, PLM; Boeve, WJ

    1999-01-01

    Background: Cirrhosis and portal hypertension affect the flow profile of the liver vasculature. In these conditions Doppler ultrasound can provide important information on the hemodynamics of the portal venous system, the hepatic artery and the hepatic veins. Methods: The value of Doppler ultrasound

  16. A Rayleigh Doppler frequency estimator derived from maximum likelihood theory

    DEFF Research Database (Denmark)

    Hansen, Henrik; Affes, Sofiéne; Mermelstein, Paul

    1999-01-01

    Reliable estimates of Rayleigh Doppler frequency are useful for the optimization of adaptive multiple access wireless receivers. The adaptation parameters of such receivers are sensitive to the amount of Doppler and automatic reconfiguration to the speed of terminal movement can optimize cell cap...

  17. DCS Budget Tracking System

    Data.gov (United States)

    Social Security Administration — DCS Budget Tracking System database contains budget information for the Information Technology budget and the 'Other Objects' budget. This data allows for monitoring...

  18. Use of GPS network data for HF Doppler measurements interpretation

    CERN Document Server

    Petrova, Inna R; Latypov, Ruslan R

    2014-01-01

    The method of measurement of Doppler frequency shift of ionospheric signal - HF Doppler technique - is one of well-known and widely used methods of ionosphere research. It allows to research various disturbances in the ionosphere. There are some sources of disturbances in the ionosphere. These are geomagnetic storms, solar flashes, metrological effects, atmospheric waves. This method allows to find out the influence of earthquakes, explosions and other processes on the ionosphere, which occur near to the Earth. HF Doppler technique has the high sensitivity to small frequency variations and the high time resolution, but interpretation of results is difficult. In this work we make an attempt to use GPS data for Doppler measurements interpretation. Modeling of Doppler frequency shift variations with use of TEC allows to separate ionosphere disturbances of medium scale.

  19. Embolic Doppler ultrasound signal detection via fractional Fourier transform.

    Science.gov (United States)

    Gençer, Merve; Bilgin, Gökhan; Aydın, Nizamettin

    2013-01-01

    Computerized analysis of Doppler ultrasound signals can aid early detection of asymptomatic circulating emboli. For analysis, physicians use informative features extracted from Doppler ultrasound signals. Time -frequency analysis methods are useful tools to exploit the transient like signals such as Embolic signals. Detection of discriminative features would be the first step toward automated analysis of embolic Doppler ultrasound signals. The most problematic part of setting up emboli detection system is to differentiate embolic signals from confusing similar wave-like patterns such as Doppler speckle and artifacts caused by tissue movement, probe tapping, speaking etc. In this study, discrete version of fractional Fourier transform is presented as a solution in the detection of emboli in digitized Doppler ultrasound signals. An accurate set of parameters are extracted using short time Fourier transform and fractional Fourier transform and the results are compared to reveal detection quality. Experimental results prove the efficiency of fractional Fourier transform in which discriminative features becomes more evident.

  20. One way Doppler extractor. Volume 1: Vernier technique

    Science.gov (United States)

    Blasco, R. W.; Klein, S.; Nossen, E. J.; Starner, E. R.; Yanosov, J. A.

    1974-01-01

    A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

  1. Limits on Planetary Companions from Doppler Surveys of Nearby Stars

    CERN Document Server

    Howard, Andrew W

    2016-01-01

    Most of our knowledge of planets orbiting nearby stars comes from Doppler surveys. For spaced-based, high-contrast imaging missions, nearby stars with Doppler-discovered planets are attractive targets. The known orbits tell imaging missions where and when to observe, and the dynamically-determined masses provide important constraints for the interpretation of planetary spectra. Quantifying the set of planet masses and orbits that could have been detected will enable more efficient planet discovery and characterization. We analyzed Doppler measurements from Lick and Keck Observatories collected by the California Planet Survey. We focused on stars that are likely targets for three space-based planet imaging mission concepts studied by NASA--WFIRST-AFTA, Exo-C, and Exo-S. The Doppler targets are primarily F8 and later main sequence stars, with observations spanning 1987-2014. We identified 76 stars with Doppler measurements from the prospective mission target lists. We developed an automated planet search and a ...

  2. Doplerovi brodski navigacioni brzinomjeri / Maritime navigational Doppler logs

    Directory of Open Access Journals (Sweden)

    Milovan Unković

    2006-01-01

    Full Text Available Doplerovi navigacioni brodski brzinomjeri rade na principu Doplerovog efekta. Doplerov predajni projektor emituje snop ultrazvučnih vibracija u vodi, a drugi (ili isti projektor prima odbijeni signal od dna ili od sloja vode. U ovom radu opisana je teorija Doplerovog efekta, primjena te teorije na brodskim brzinomjerima, konstrukcija i karakteristike savremenih Doplerovih brzinomjera. / The Doppler maritime navigational logs are based on measurement of the Doppler effect. A Doppler log transmitting transducer emits beam of sound vibration in the water, and a second (or the same transducer receives the echo from the sea bed or -water layer. In this article describes theory of Doppler effect, using this theory in maritime logs, construction and performance of modern Doppler logs.

  3. An improved Bernese Moon gravity field and tidal Love number k2 solution from GRAIL Doppler and KBRR data

    Science.gov (United States)

    Bertone, Stefano; Arnold, Daniel; Jäggi, Adrian; Mervart, Leos

    2016-10-01

    The NASA mission GRAIL inherits its concept from the GRACE mission to determine the gravity field of the Moon. Beside one-way and two-way Doppler tracking from Earth, GRAIL uses inter-satellite Ka-band range-rate (KBRR) observations to enable data acquisition even when the spacecraft are not tracked from the Earth. The data allows for a highly accurate estimation of the lunar gravity field on both sides of the Moon, which is leading to huge improvements in our understanding of its internal structure and thermal evolution. This led to a spectacular resolution of as few as 7 km for the gravity field in the latest solutions by NASA JPL and GSFC teams.The Astronomical Institute of the University of Bern (AIUB) recently started the development of deep space Doppler data processing within the Bernese GNSS Software, which has been long used in orbit determination of low Earth orbiting satellites and Earth gravity field determination. In this presentation we discuss the latest GRAIL-based orbit and gravity field solutions generated with the Celestial Mechanics Approach using the Bernese GNSS Software.Based on Doppler data, we perform orbit determination by solving six initial orbital elements, dynamical parameters, and stochastic parameters in daily arcs using least-squares adjustment. The pseudo-stochastic parameters are estimated to absorb deficiencies in our dynamical modeling (e.g. due to non-gravitational forces). Doppler and KBRR data are then used together with an appropriate weighting for a combined orbit and gravity field determination process.We present our independent solutions of the lunar gravity field up to d/o 300, where KBRR data and Doppler 1-way and 2-way observations from the primary mission phase (PM, March-May 2012) are used. We compare and evaluate the impact of 1-way and 2-way Doppler data on our results. Moreover, we present our first solution for the Moon tidal Love number k2.We compare all of our results from the PM with the most recent lunar

  4. CWI at TREC 2012, KBA track and Session Track

    NARCIS (Netherlands)

    Araújo, S.; Boscarino, C.; Gebremeskel, G.G.; He, J.; Vries, A.P. de; Voorhees, E.M.; Buckland, L. P.

    2013-01-01

    We participated in two tracks: Knowledge Base Acceleration (KBA) Track and Session Track. In the KBA track, we focused on experi- menting with different approaches as it is the first time the track is launched. We experimented with supervised and unsupervised re- trieval models. Our supervised appro

  5. CWI at TREC 2012, KBA track and Session Track

    NARCIS (Netherlands)

    S. Araújo (Samur); C. Boscarino (Corrado); G.G. Gebremeskel (Gebre); J. He (Jiyin); A.P. de Vries (Arjen)

    2013-01-01

    htmlabstractWe participated in two tracks: Knowledge Base Acceleration (KBA) Track and Session Track. In the KBA track, we focused on experi- menting with different approaches as it is the first time the track is launched. We experimented with supervised and unsupervised re- trieval models. Our supe

  6. TIMED Doppler Interferometer: Overview and recent results

    Science.gov (United States)

    Killeen, T. L.; Wu, Q.; Solomon, S. C.; Ortland, D. A.; Skinner, W. R.; Niciejewski, R. J.; Gell, D. A.

    2006-10-01

    The Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics (TIMED) satellite carries a limb-scanning Fabry-Perot interferometer designed to perform remote-sensing measurements of upper atmosphere winds and temperatures globally. This instrument is called the TIMED Doppler Interferometer, or TIDI. This paper provides an overview of the TIDI instrument design, on-orbit performance, operational modes, data processing and inversion procedures, and a summary of wind results to date. Daytime and nighttime neutral winds in the mesosphere and lower thermosphere/ionosphere (MLTI) are measured on TIDI using four individual scanning telescopes that collect light from various upper atmosphere airglow layers on both the cold and warm sides of the high-inclination TIMED spacecraft. The light is spectrally analyzed using an ultrastable plane etalon Fabry-Perot system with sufficient spectral resolution to determine the Doppler line characteristics of atomic and molecular emissions emanating from the MLTI. The light from all four telescopes and from an internal calibration field passes through the etalon and is combined on a single image plane detector using a Circle-to-Line Interferometer Optic (CLIO). The four geophysical fields provide orthogonal line-of-sight measurements to either side of the satellite's path and these are analyzed to produce altitude profiles of vector winds in the MLTI. The TIDI wind measurements presented here are from the molecular oxygen (0-0) band, covering the altitude region 85-105 km. The unique TIDI design allows for more extended local time coverage of wind structures than previous wind-measuring instruments from high-inclination satellites. The TIDI operational performance has been nominal except for two anomalies: (1) higher than expected background white light caused by a low-level light leak and (2) ice deposition on cold optical surfaces. Both anomalies are well understood and the instrumental modes and data analysis techniques have been

  7. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  8. Universal miniaturized signal evaluation for laser doppler anemometers; Universelle Miniatur-Signalauswertung fuer die Laser Doppler Anemometrie

    Energy Technology Data Exchange (ETDEWEB)

    Wnuck, J. von; Strunck, V.; Dopheide, D.

    1994-01-01

    A laser doppler anemometer (LDA) is a contactless optical sensor for flow rate measurement. Interference of two laser beams generates a measuring volume with interference lines in the point of intersection. A particle moving through the measuring volume with a current scatters light modulated wiith the doppler frequency, which is received by a detector. The frequency of the doppler-modulated light is proportional to the velocity of the particle. The report describes the technical details of an electronic evaluation system for laser doppler signals in the time range using programmable gate arrays by Xilinix. (orig.) [Deutsch] Ein Laser Doppler Anemometer (LDA) ist ein beruehrungsloser optischer Sensor, der Stroemungsgeschwindigkeiten misst. Die Ueberlagerung zweier Laserstrahlen erzeugt im Schnittpunkt ein Messvolumen mit Inferenzstreifen. Ein Teilchen, das sich mit einer Stroemung durch das Messvolumen bewegt, streut mit der Doppelfrequenz des Doppler moduliertes Licht, das von einem Detektor empfangen wird. Die Frequenz des Doppler-modulierten Lichts ist der Geschwindigkeit des Teilchens proportional. Hier wird die technische Realisierung einer Auswerteelektronik fuer Laser Doppler Signale im Zeitbereich mit programmierbaren Gate-Arrays von Xilinx beschrieben. (orig.)

  9. Color Doppler US of superficial adenopathies; Il color Doppler nelle adenopatie superficiali

    Energy Technology Data Exchange (ETDEWEB)

    Giovagnorio, F. [Rome Univ. (Italy). 1. Cattedra di Radiologia

    1999-03-01

    Superficial lymph node are frequently involved in different diseases. Their location makes them suitable for effective assessment with high-resolution US and color Doppler has been recently suggested as a tool for increasing sensitivity in lymph node studies. Thus the author investigated the main vascular patterns detectable in abnormal superficial lymph nodes. [Italian] Numerosa malattie con natura differente coinvolgono i linfonodi superficiali: la localizzazione ne consente l'esplorazione con ecografia con alta risoluzione e lo studio mediante eco color Doppler e' stato proposto negli ultimi anni incontrando notevole sviluppo in tempi recenti. Scopo del lavoro e' illustrare il contributo personale nella definizione dei principali quadri riscontrabili nelle diverse adenopatie superficiali.

  10. Fractal fluctuations in transcranial Doppler signals

    Science.gov (United States)

    West, B. J.; Zhang, R.; Sanders, A. W.; Miniyar, S.; Zuckerman, J. H.; Levine, B. D.

    1999-03-01

    Cerebral blood flow (CBF) velocity measured using transcranial Doppler ultrasonography (TCD) is not strictly constant, but has both a systematic and random component. This behavior may indicate that the axial blood flow in the middle cerebral artery is a chaotic process. Herein we use the relative dispersion, the ratio of the standard deviation to the mean, to show by systematically aggregating the data that the correlation in the beat-to-beat CBF time series is a modulated inverse power law. This scaling of the CBF time series indicates the existence of long-time memory in the underlying control process. We argue herein that the control system has allometric properties that enable it to maintain a relatively constant brain perfusion.

  11. Role of transcranial Doppler in cerebrovascular disease

    Directory of Open Access Journals (Sweden)

    Amit A Kulkarni

    2016-01-01

    Full Text Available Transcranial Doppler (TCD is the only noninvasive modality for the assessment of real-time cerebral blood flow. It complements various anatomic imaging modalities by providing physiological-flow related information. It is relatively cheap, easily available, and can be performed at the bedside. It has been suggested as an essential component of a comprehensive stroke centre. In addition to its importance in acute cerebrovascular ischemia, its role is expanding in the evaluation of cerebral hemodynamics in various disorders of the brain. The “established” clinical indications for the use of TCD include cerebral ischemia, sickle cell disease, detection of right-to-left shunts, subarachnoid hemorrhage, periprocedural or surgical monitoring, and brain death. We present the role of TCD in acute cerebrovascular ischemia, sonothrombolysis, and intracranial stenosis.

  12. The Doppler peaks from a generic defect

    CERN Document Server

    Magueijo, J

    1996-01-01

    We investigate which of the exotic Doppler peak features found for textures and cosmic strings are generic novelties pertaining to defects. We find that the ``out of phase'' texture signature is an accident. Generic defects, when they generate a secondary peak structure similar to inflation, apply to it an additive shift. It is not necessary for this shift to be ``out of phase''. We also show which factors are responsible for the absence of secondary oscillations found for cosmic strings. Within this general analysis we finally consider the conditions under which topological defects and inflation can be confused. It is argued that only \\Omega=1 inflation and a defect with a horizon size coherence length have a chance to be confused. Any other inflationary or defect model always differ distinctly. (To appear in the proceedings of the XXXIth Moriond meeting, ``Microwave Background Anisotropies'')

  13. Laser Doppler vibrometry: new ENT applications

    Science.gov (United States)

    Stasche, Norbert; Baermann, M.; Kempe, C.; Hoermann, Karl; Foth, Hans-Jochen

    1996-12-01

    Common audiometry often does not really allow a reliable and objective differential diagnosis of hearing disorders such as otosclerosis, adhesive otitis, ossicular interruption or tinnitus, even though several methods might be used complementarily. In recent years, some experimental studies on middle ear mechanics established laser Doppler vibrometry (LDV) as a useful method allowing objective measurement of human tympanic membrane displacement. The present study on LDV investigated the clinical use of this new method under physiological conditions. LDV proved to be a fast, reproducible, non-invasive and very sensitive instrument to characterize ear-drum vibrations in various middle ear dysfunctions, except in tinnitus patients. For future applications, improved optical characteristics of the vibrometer might result in a better differential diagnosis of subjective and objective tinnitus, otoacoustic emissions or Morbus Meniere.

  14. Heartrate variation of umbilical artery Doppler waveforms.

    Science.gov (United States)

    Hoskins, P R; Johnstone, F D; Chambers, S E; Haddad, N G; White, G; McDicken, W N

    1989-01-01

    Umbilical artery Doppler waveforms from 20 patients were used to investigate the dependence of resistance index and pulsatility index on beat to beat pulse length over short time periods for individual patients, and on the usefulness of a common normalisation formula. For individual patients the resistance index and pulsatility index were only partially correlated with pulse length. Changes in both indices occurred independently of pulse length. Use of a common normalisation formula resulted in no significant reduction of the coefficient of variation of the resistance index (p greater than 0.1), and a reduction in the coefficient of variation of the pulsatility index of 10% (p greater than 0.001). It is concluded that short term changes in resistance index and pulsatility index cannot be corrected by a common normalisation formula.

  15. Correlation and Sequential Filtering with Doppler Measurements

    Institute of Scientific and Technical Information of China (English)

    WANGJianguo; HEPeikun; HANYueqiu; WUSiliang

    2004-01-01

    Two sequential filters are developed for Doppler radar measurements in the presence of correlation between range and range rate measurement errors. Two ideal linear measurement equations with the pseudo measurements are constructed via block-partitioned Cholesky factorization and the practical measurement equationswith the pseudo measurements are obtained through the direction cosine estimation and error compensation. The resulting sequential filters make the position measurement be possibly processed before the pseudo measurement and hence the more accurate direction cosine estimate can be obtained from the filtered position estimate rather than the predicted state estimate. The numerical simulations with different rangerange rate correlation coefficients show thatthe proposed two sequential filters are almost equivalent in performance but both superior to the conventional extended Kalman filter for different correlation coefficients.

  16. Doppler cooling and trapping on forbidden transitions.

    Science.gov (United States)

    Binnewies, T; Wilpers, G; Sterr, U; Riehle, F; Helmcke, J; Mehlstäubler, T E; Rasel, E M; Ertmer, W

    2001-09-17

    Ultracold atoms at temperatures close to the recoil limit have been achieved by extending Doppler cooling to forbidden transitions. A cloud of (40)Ca atoms has been cooled and trapped to a temperature as low as 6 microK by operating a magnetooptical trap on the spin-forbidden intercombination transition. Quenching the long-lived excited state with an additional laser enhanced the scattering rate by a factor of 15, while a high selectivity in velocity was preserved. With this method, more than 10% of precooled atoms from a standard magnetooptical trap have been transferred to the ultracold trap. Monte Carlo simulations of the cooling process are in good agreement with the experiments.

  17. Phase Doppler anemometry as an ejecta diagnostic

    Science.gov (United States)

    Bell, D. J.; Chapman, D. J.

    2017-01-01

    When a shock wave is incident on a free surface, micron sized pieces of the material can be ejected from that surface. Phase Doppler Anemometry (PDA) is being developed to simultaneously measure the sizes and velocities of the individual shock induced ejecta particles; providing an important insight into ejecta phenomena. The results from experiments performed on the 13 mm bore light gas gun at the Institute of Shock Physics, Imperial College London are presented. Specially grooved tin targets were shocked at pressures of up to 14 GPa, below the melt on release pressure, to generate ejecta particles. These experiments are the first time that PDA has been successfully fielded on dynamic ejecta experiments. The results and current state of the art of the technique are discussed along with the future improvements required to optimise performance and increase usability.

  18. Calibration of a cw infrared Doppler lidar.

    Science.gov (United States)

    Schwiesow, R L; Cupp, R E

    1980-09-15

    A moving scattering target used as a transfer standard allows absolute calibration of the response of a cw Doppler lidar to an atmospheric target. The lidar in this study operated at a 10.6-microm wavelength. Consideration of the distribution of radiant energy density near the focus of the lidar transceiver permits measurement of a backscatter coefficient from a distributed array of scatterers, such as atmospheric aerosols, based on the diffuse reflectance of the surface of the transfer standard. The minimum detectable signal for our system with a 5-sec averaging time corresponds to a backscatter coefficient of 2.4 x 10(-12) m (-1) sr (-1) +/- 2.5 dB, which is ~ 9 dB greater than the theoretical threshold. Calibration shows that the lidar response is 5+/-1 dB less than the ideal limit for signal powers well above the minimum detectable signal.

  19. The recondite intricacies of Zeeman Doppler mapping

    CERN Document Server

    Stift, M J; Cowley, C R

    2011-01-01

    We present a detailed analysis of the reliability of abundance and magnetic maps of Ap stars obtained by Zeeman Doppler mapping (ZDM). It is shown how they can be adversely affected by the assumption of a mean stellar atmosphere instead of appropriate "local" atmospheres corresponding to the actual abundances in a given region. The essenceof the difficulties was already shown by Chandrasekhar's picket-fence model. The results obtained with a suite of Stokes codes written in the Ada programming language and based on modern line-blanketed atmospheres are described in detail. We demonstrate that the high metallicity values claimed to have been found in chemically inhomogeneous Ap star atmospheres would lead to local temperature structures, continuum and line intensities, and line shapes that differ significantly from those predicted by a mean stellar atmosphere. Unfortunately, past applications of ZDM have consistently overlooked the intricate aspects of metallicity with their all-pervading effects. The erroneou...

  20. Position finding using simple Doppler sensors

    Science.gov (United States)

    Schelkshorn, S.; Detlefsen, J.

    2007-06-01

    An increasing number of modern applications and services is based on the knowledge of the users actual position. Depending on the application a rough position estimate is sufficient, e. g. services in cellular networks that use the information about the users actual cell. Other applications, e. g. navigation systems use the GPS-System for accurate position finding. Beyond these outdoor applications a growing number of indoor applications requires position information. The previously mentioned methods for position finding (mobile cell, GPS) are not usable for these indoor applications. Within this paper we will present a system that relies on the simultaneous measurement of doppler signals at four different positions to obtain position and velocity of an unknown object. It is therefore suiteable for indoor usage, extendig already existing wireless infrastructure.

  1. Microscale Heat Conduction Models and Doppler Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Hawari, Ayman I. [North Carolina State Univ., Raleigh, NC (United States); Ougouag, Abderrafi [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-01-22

    The objective of this project is to establish an approach for providing the fundamental input that is needed to estimate the magnitude and time-dependence of the Doppler feedback mechanism in Very High Temperature reactors. This mechanism is the foremost contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic (TRISO) coated particles. Therefore, its correct prediction is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat deposition, heat transfer and temperature rise must be correctly predicted. To achieve the above objective, this project will explore an approach that accounts for lattice effects as well as local temperature variations and the correct definition of temperature and related local effects.

  2. Doppler time-of-flight imaging

    KAUST Repository

    Heidrich, Wolfgang

    2017-02-16

    Systems and methods for imaging object velocity are provided. In an embodiment, at least one Time-of-Flight camera is used to capture a signal representative of an object in motion over an exposure time. Illumination and modulation frequency of the captured motion are coded within the exposure time. A change of illumination frequency is mapped to measured pixel intensities of the captured motion within the exposure time, and information about a Doppler shift in the illumination frequency is extracted to obtain a measurement of instantaneous per pixel velocity of the object in motion. The radial velocity information of the object in motion can be simultaneously captured for each pixel captured within the exposure time. In one or more aspects, the illumination frequency can be coded orthogonal to the modulation frequency of the captured motion. The change of illumination frequency can correspond to radial object velocity.

  3. Analytic radar micro-Doppler signatures classification

    Science.gov (United States)

    Oh, Beom-Seok; Gu, Zhaoning; Wang, Guan; Toh, Kar-Ann; Lin, Zhiping

    2017-06-01

    Due to its capability of capturing the kinematic properties of a target object, radar micro-Doppler signatures (m-DS) play an important role in radar target classification. This is particularly evident from the remarkable number of research papers published every year on m-DS for various applications. However, most of these works rely on the support vector machine (SVM) for target classification. It is well known that training an SVM is computationally expensive due to its nature of search to locate the supporting vectors. In this paper, the classifier learning problem is addressed by a total error rate (TER) minimization where an analytic solution is available. This largely reduces the search time in the learning phase. The analytically obtained TER solution is globally optimal with respect to the classification total error count rate. Moreover, our empirical results show that TER outperforms SVM in terms of classification accuracy and computational efficiency on a five-category radar classification problem.

  4. Widefield laser doppler velocimeter: development and theory.

    Energy Technology Data Exchange (ETDEWEB)

    Hansche, Bruce David; Reu, Phillip L.; Massad, Jordan Elias

    2007-03-01

    The widefield laser Doppler velocimeter is a new measurement technique that significantly expands the functionality of a traditional scanning system. This new technique allows full-field velocity measurements without scanning, a drawback of traditional measurement techniques. This is particularly important for tests in which the sample is destroyed or the motion of the sample is non-repetitive. The goal of creating ''velocity movies'' was accomplished during the research, and this report describes the current functionality and operation of the system. The mathematical underpinnings and system setup are thoroughly described. Two prototype experiments are then presented to show the practical use of the current system. Details of the corresponding hardware used to collect the data and the associated software to analyze the data are presented.

  5. Doppler spectral characteristics of infrainguinal vein bypasses

    DEFF Research Database (Denmark)

    Nielsen, Tina G; von Jessen, F; Sillesen, H

    1993-01-01

    With the aim of assessing the velocity profile of femoropopliteal and femorocrural vein bypasses, 128 patients undergoing infrainguinal vein bypass surgery entered a postoperative Duplex surveillance protocol, which included clinical assessment and Duplex scanning, using Doppler spectral analysis...... of arteriovenous fistulas the initially antegrade diastolic velocity was replaced by a retrograde flow within 3 months, whereas a forward flow in diastole was sustained in grafts with patent fistulas. Abnormal Duplex findings in 31 patients led to angiography and revision in 13 cases. Four revised grafts failed......, while nine remained patent at follow-up 1-12 months later. Ten (56%) of 18 non-revised bypasses with abnormal Duplex findings failed within 9 months compared to 1 (1%) of 76 bypasses with a normal velocity profile (p analysis provides...

  6. On the Wrong Track?

    Science.gov (United States)

    Gursky, Daniel

    1990-01-01

    Discusses problems with student tracking. Although supporters consider tracking the best way for teachers to handle classroom diversity, many minorities say that it condemns their children to an inferior education. Studies show that heterogeneous classes benefit all students if the teachers adopt flexible instructional methods to handle the…

  7. Can Tracking Improve Learning?

    Science.gov (United States)

    Duflo, Esther; Dupas, Pascaline; Kremer, Michael

    2009-01-01

    Tracking students into different classrooms according to their prior academic performance is controversial among both scholars and policymakers. If teachers find it easier to teach a homogeneous group of students, tracking could enhance school effectiveness and raise test scores of both low- and high-ability students. If students benefit from…

  8. Can Tracking Improve Learning?

    Science.gov (United States)

    Duflo, Esther; Dupas, Pascaline; Kremer, Michael

    2009-01-01

    Tracking students into different classrooms according to their prior academic performance is controversial among both scholars and policymakers. If teachers find it easier to teach a homogeneous group of students, tracking could enhance school effectiveness and raise test scores of both low- and high-ability students. If students benefit from…

  9. Large scale tracking algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Ross L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Love, Joshua Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Melgaard, David Kennett [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Karelitz, David B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pitts, Todd Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zollweg, Joshua David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Anderson, Dylan Z. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nandy, Prabal [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Whitlow, Gary L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bender, Daniel A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Byrne, Raymond Harry [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Low signal-to-noise data processing algorithms for improved detection, tracking, discrimination and situational threat assessment are a key research challenge. As sensor technologies progress, the number of pixels will increase signi cantly. This will result in increased resolution, which could improve object discrimination, but unfortunately, will also result in a significant increase in the number of potential targets to track. Many tracking techniques, like multi-hypothesis trackers, suffer from a combinatorial explosion as the number of potential targets increase. As the resolution increases, the phenomenology applied towards detection algorithms also changes. For low resolution sensors, "blob" tracking is the norm. For higher resolution data, additional information may be employed in the detection and classfication steps. The most challenging scenarios are those where the targets cannot be fully resolved, yet must be tracked and distinguished for neighboring closely spaced objects. Tracking vehicles in an urban environment is an example of such a challenging scenario. This report evaluates several potential tracking algorithms for large-scale tracking in an urban environment.

  10. Incentives from Curriculum Tracking

    Science.gov (United States)

    Koerselman, Kristian

    2013-01-01

    Curriculum tracking creates incentives in the years before its start, and we should therefore expect test scores to be higher during those years. I find robust evidence for incentive effects of tracking in the UK based on the UK comprehensive school reform. Results from the Swedish comprehensive school reform are inconclusive. Internationally, I…

  11. Bewegingsvolgsysteem = Monitor tracking system

    NARCIS (Netherlands)

    Slycke, Per Johan; Veltink, Petrus Hermanus; Roetenberg, Daniel

    2006-01-01

    A motion tracking system for tracking an object composed of object parts in a three-dimensional space. The system comprises a number of magnetic field transmitters; a number of field receivers for receiving the magnetic fields of the field transmitters; a number of inertial measurement units for rec

  12. Bewegingsvolgsysteem = Monitor tracking system

    NARCIS (Netherlands)

    Slycke, Per Johan; Veltink, Petrus Hermanus; Roetenberg, Daniel

    2007-01-01

    A motion tracking system for tracking an object composed of object parts in a three-dimensional space. The system comprises a number of magnetic field transmitters; a number of field receivers for receiving the magnetic fields of the field transmitters; a number of inertial measurement units for rec

  13. Eye-Tracking

    Directory of Open Access Journals (Sweden)

    Gabriela GROSSECK

    2006-01-01

    Full Text Available Eye-tracking: one of the newest and most efficient methods of improving on-line marketing communication is called eye-tracking. Marketers have borrowed this technique, usually used in psychological and medical research, in order to study web users with the help of a video camera incorporated in the monitor.

  14. Large scale tracking algorithms.

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Ross L.; Love, Joshua Alan; Melgaard, David Kennett; Karelitz, David B.; Pitts, Todd Alan; Zollweg, Joshua David; Anderson, Dylan Z.; Nandy, Prabal; Whitlow, Gary L.; Bender, Daniel A.; Byrne, Raymond Harry

    2015-01-01

    Low signal-to-noise data processing algorithms for improved detection, tracking, discrimination and situational threat assessment are a key research challenge. As sensor technologies progress, the number of pixels will increase signi cantly. This will result in increased resolution, which could improve object discrimination, but unfortunately, will also result in a significant increase in the number of potential targets to track. Many tracking techniques, like multi-hypothesis trackers, suffer from a combinatorial explosion as the number of potential targets increase. As the resolution increases, the phenomenology applied towards detection algorithms also changes. For low resolution sensors, "blob" tracking is the norm. For higher resolution data, additional information may be employed in the detection and classfication steps. The most challenging scenarios are those where the targets cannot be fully resolved, yet must be tracked and distinguished for neighboring closely spaced objects. Tracking vehicles in an urban environment is an example of such a challenging scenario. This report evaluates several potential tracking algorithms for large-scale tracking in an urban environment.

  15. Ultrasonic intrusion sensor using the Doppler effect; Choonpa Doppler hoshiki shinnyu sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kani, H.; Iwasaki, N.; Goto, M. [Nippon Soken, Inc., Tokyo (Japan); Tsuzuki, T.; Nakamura, T. [Denso Corp., Aichi (Japan)

    1997-10-01

    For vehicle anti-theft alarm systems which cope with vehicle and car component theft, EU initiated vehicle security regulations from Jan 1997. Also, the insurance industry has instituted the insurance certification of vehicle anti-theft alarm systems. We have developed an ultrasonic intrusion sensor using the doppler effect for vehicle anti-theft alarm systems specifically for these EU regulations and insurance certification. 2 refs., 7 figs., 1 tab.

  16. Laser Doppler flowmetry in endodontics: a review.

    Science.gov (United States)

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  17. Target detection in pulse-Doppler radar based on multi-scanning signal integration

    Directory of Open Access Journals (Sweden)

    O. S. Neuimin

    2013-07-01

    Full Text Available Introduction. Development of multi-scanning signal integration algorithms for pulseDoppler radars which are widely used in practice is of great practical importance. Problem statement. The problem of multi-scanning signal integration measuring range and range-rate is considered. The reflected signal from a target is a distorted white noise coherent packet of radio pulses with random initial phase and known amplitude. Target detection in a sequence of radar scans is reduced to the detection of target track. Development of a two-step multi-scanning incoherent signal integration algorithm. Two-step integration method is applied to reduce the number of tracks. In the first stage the initial signals detection with a sufficiently high probability of false alarm is performed. In the second stage the tracking problem for selection target markers is solved and the multiscanning signal integration is implemented. It provides an optimal target detection solution over K surveys with low signal-to-noise ratio. Expressions for the correct target detection probability and false alarm incorporating quality track tracking are obtained. Simulation results. Analysis of the algorithm is carried out as example of the little maneuvering target detection using the statistical modeling. The methods of calculating the output threshold (the cumulative statistics are compared on it is presented. Conclusions. Increasing the number of scans (in which the integration are performed leads to a significant decreasing the probability of false alarm, which allows to increase the signal-to-noise ratio compared with the detection in a single scan up to 3.5 dB.

  18. Sparse Hashing Tracking.

    Science.gov (United States)

    Zhang, Lihe; Lu, Huchuan; Du, Dandan; Liu, Luning

    2016-02-01

    In this paper, we propose a novel tracking framework based on a sparse and discriminative hashing method. Different from the previous work, we treat object tracking as an approximate nearest neighbor searching process in a binary space. Using the hash functions, the target templates and the candidates can be projected into the Hamming space, facilitating the distance calculation and tracking efficiency. First, we integrate both the inter-class and intra-class information to train multiple hash functions for better classification, while most classifiers in previous tracking methods usually neglect the inter-class correlation, which may cause the inaccuracy. Then, we introduce sparsity into the hash coefficient vectors for dynamic feature selection, which is crucial to select the discriminative and stable features to adapt to visual variations during the tracking process. Extensive experiments on various challenging sequences show that the proposed algorithm performs favorably against the state-of-the-art methods.

  19. TRACKED VEHICLE Rev 75

    Energy Technology Data Exchange (ETDEWEB)

    2007-05-08

    Revision 75 of the Tracked Vehicle software is a soft real-time simulation of a differentially steered, tracked mobile robot, which, because of the track flippers, resembles the iRobot PackBot (http://www.irobot.com/). Open source libraries are used for the physics engine (http://www.ode.org/), the display and user interface (http://www.mathies.com/cpw/), and the program command line and configuration file parameters (http://www.boost.org/). The simulation can be controlled by a USB joystick or the keyboard. The configuration file contains demonstration model parameters of no particular vehicle. This simulation can be used as a starting point for those doing tracked vehicle simulations. This simulation software is essentially a research tool which can be modified and adapted for certain types of tracked vehicle research. An open source license allows an individual researchers to tailor the code to their specific research needs.

  20. Function and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking

    OpenAIRE

    Arias-Godínez,José Antonio; Guadalajara-Boo,José Fernando; Patel, Ayan R; Pandian, Natesa G.

    2011-01-01

    One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to carry out and with superior accuracy and reproducibility. However, regional myocardial function is mo...

  1. Function and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking

    OpenAIRE

    Arias-Godínez,José Antonio; Guadalajara-Boo,José Fernando; Patel,Ayan R.; Pandian, Natesa G

    2011-01-01

    One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to carry out and with superior accuracy and reproducibility. However, regional myocardial function is mo...

  2. Persistent Aerial Tracking

    KAUST Repository

    Mueller, Matthias

    2016-04-13

    In this thesis, we propose a new aerial video dataset and benchmark for low altitude UAV target tracking, as well as, a photo-realistic UAV simulator that can be coupled with tracking methods. Our benchmark provides the rst evaluation of many state of-the-art and popular trackers on 123 new and fully annotated HD video sequences captured from a low-altitude aerial perspective. Among the compared trackers, we determine which ones are the most suitable for UAV tracking both in terms of tracking accuracy and run-time. We also present a simulator that can be used to evaluate tracking algorithms in real-time scenarios before they are deployed on a UAV "in the field", as well as, generate synthetic but photo-realistic tracking datasets with free ground truth annotations to easily extend existing real-world datasets. Both the benchmark and simulator will be made publicly available to the vision community to further research in the area of object tracking from UAVs. Additionally, we propose a persistent, robust and autonomous object tracking system for unmanned aerial vehicles (UAVs) called Persistent Aerial Tracking (PAT). A computer vision and control strategy is applied to a diverse set of moving objects (e.g. humans, animals, cars, boats, etc.) integrating multiple UAVs with a stabilized RGB camera. A novel strategy is employed to successfully track objects over a long period, by \\'handing over the camera\\' from one UAV to another. We integrate the complete system into an off-the-shelf UAV, and obtain promising results showing the robustness of our solution in real-world aerial scenarios.

  3. The Coplane Analysis Technique for Three-Dimensional Wind Retrieval Using the HIWRAP Airborne Doppler Radar

    Science.gov (United States)

    Didlake, Anthony C., Jr.; Heymsfield, Gerald M.; Tian, Lin; Guimond, Stephen R.

    2015-01-01

    The coplane analysis technique for mapping the three-dimensional wind field of precipitating systems is applied to the NASA High Altitude Wind and Rain Airborne Profiler (HIWRAP). HIWRAP is a dual-frequency Doppler radar system with two downward pointing and conically scanning beams. The coplane technique interpolates radar measurements to a natural coordinate frame, directly solves for two wind components, and integrates the mass continuity equation to retrieve the unobserved third wind component. This technique is tested using a model simulation of a hurricane and compared to a global optimization retrieval. The coplane method produced lower errors for the cross-track and vertical wind components, while the global optimization method produced lower errors for the along-track wind component. Cross-track and vertical wind errors were dependent upon the accuracy of the estimated boundary condition winds near the surface and at nadir, which were derived by making certain assumptions about the vertical velocity field. The coplane technique was then applied successfully to HIWRAP observations of Hurricane Ingrid (2013). Unlike the global optimization method, the coplane analysis allows for a transparent connection between the radar observations and specific analysis results. With this ability, small-scale features can be analyzed more adequately and erroneous radar measurements can be identified more easily.

  4. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  5. Doppler sensitivity and its effect on transatlantic TWSTFT links

    Science.gov (United States)

    Zhang, Shengkang; Parker, Thomas; Zhang, Victor

    2017-02-01

    Some investigations have concluded that the diurnal pattern in the time comparison results of present two way satellite time and frequency transfer (TWSTFT) links may come mainly from Doppler dependent errors in the time of arrival (TOA) measurements made by the receivers of the TWSTFT modems. In this paper, several experiments were carried out to test if there is a Doppler dependent error in the ‘delay’ measurements of the receivers currently used. By simulating quantitative Doppler effects in the time transfer signal both on the carrier and the code, a type of Doppler sensitivity on the code was observed in the receivers, which has about  -0.49 ns offset in ‘delay’ measurement for a 1  ×  10-9 fractional Doppler shift. This sensitivity is basically the same for modems with different serial numbers from the same manufacture. We calculated this Doppler caused diurnal pattern in the time comparison results of the transatlantic TWSTFT link between NIST and PTB and found that it is very small and negligible, because the Doppler dependent error is almost identical in the NIST and PTB measurements and therefore it is nearly canceled in the TWSTFT difference. Commercial products are identified for technical completeness only, and no endorsement by NIST is implied.

  6. Ionospheric observations made by a time-interleaved Doppler ionosonde

    Science.gov (United States)

    Lynn, Kenneth J. W.

    2008-10-01

    Mid-latitude HF observations of ionospheric Doppler velocity as a function of frequency are reported here as observed over a quiet 24-h period by a KEL IPS71 ionosonde operating at a 5-min sampling rate. The unique time-interleaving technique used in this ionosonde provided a Doppler resolution of 0.04 Hz over a Doppler range of ±2.5 Hz at each sounding frequency via FFT processing and is described here for the first time. The time-interleaving technique can be applied to other types of ionosonde as well as to other applications. The measurements described were made at a middle latitude site (Salisbury, South Australia). Doppler variations (rate-of-change of foF2 as predicted by a simple parabolic layer model. The descending cusp in short-period TIDs is shown to mark an abrupt change with increasing frequency from negative towards positive Doppler shift with the greatest change in Doppler shift being observed below the cusp. The “smilergram” is introduced as observed in both F2 and Sporadic E. The characteristic curve in Doppler versus group height at a single frequency is described and related to changes in reflection symmetry, velocity and depth of moving ionospheric inhomogeneities.

  7. Gamma ray tracking with the AGATA demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Birkenbach, Benedikt; Hess, Herbert; Lewandowski, Lars; Reiter, Peter; Steinbach, Tim; Schneiders, David; Vogt, Andreas [IKP, Universitaet zu Koeln (Germany); Collaboration: AGATA-Collaboration

    2014-07-01

    The performance of the AGATA demonstrator will be discussed based on data taken from a multi-nucleon transfer experiment at the AGATA PRISMA setup at LNL (INFN, Italy). A primary {sup 136}Xe beam of 1 GeV hitting a {sup 238}U target was used to produce a multitude of nuclei in the vicinity of {sup 136}Xe and corresponding reaction partners in the actinide region. The obtained results for in-beam gamma-ray spectroscopy allow for a critical assessment of the novel gamma ray tracking technique and comparison with standard procedure. High resolution spectroscopy of both reaction products after multi-nucleon transfer reaction in the presence of a high background from excited fission fragments is based on pulse-shape analysis (PSA) and gamma-ray tracking (GRT). The quality of the position information is crucial for the final energy resolution after Doppler correction. The impact of the calculated PSA libraries and the initial detector characterization for the PSA and GRT are summarized. Details of the achieved position and energy resolution, peak-to-background optimization are presented and illustrated with results from the neutron-transfer products in Xe and U-isotopes.

  8. Pulsed Doppler echocardiographic analysis of mitral regurgitation after myocardial infarction.

    Science.gov (United States)

    Loperfido, F; Biasucci, L M; Pennestri, F; Laurenzi, F; Gimigliano, F; Vigna, C; Rossi, E; Favuzzi, A; Santarelli, P; Manzoli, U

    1986-10-01

    In 72 patients with previous myocardial infarction (MI), mitral regurgitation (MR) was assessed by pulsed-wave Doppler echocardiography and compared with physical and 2-dimensional echocardiographic findings. MR was found by Doppler in 29 of 42 patients (62%) with anterior MI, 11 of 30 (37%) with inferior MI (p less than 0.01) and in none of 20 normal control subjects. MR was more frequent in patients who underwent Doppler study 3 months after MI than in those who underwent Doppler at discharge (anterior MI = 83% vs 50%, p less than 0.01; inferior MI = 47% vs 27%, p = not significant). Of 15 patients who underwent Doppler studies both times, 3 (all with anterior MI) had MR only on the second study. Of the patients with Doppler MR, 12 of 27 (44%) with a left ventricular (LV) ejection fraction (EF) greater than 30% and 1 of 13 (8%) with an EF of 30% or less (p less than 0.01) had an MR systolic murmur. Mitral prolapse or eversion and papillary muscle fibrosis were infrequent in MI patients, whether or not Doppler MR was present. The degree of Doppler MR correlated with EF (r = -0.61), LV systolic volume (r = 0.47), and systolic and diastolic mitral anulus circumference (r = 0.52 and 0.51, respectively). Doppler MR was present in 24 of 28 patients (86%) with an EF of 40% or less and in 16 of 44 (36%) with EF more than 40% (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Limits on Planetary Companions from Doppler Surveys of Nearby Stars

    Science.gov (United States)

    Howard, Andrew W.; Fulton, Benjamin J.

    2016-11-01

    Most of our knowledge of planets orbiting nearby stars comes from Doppler surveys. For spaced-based, high-contrast imaging missions, nearby stars with Doppler-discovered planets are attractive targets. The known orbits tell imaging missions where and when to observe, and the dynamically determined masses provide important constraints for the interpretation of planetary spectra. Quantifying the set of planet masses and orbits that could have been detected will enable more efficient planet discovery and characterization. We analyzed Doppler measurements from Lick and Keck Observatories by the California Planet Survey. We focused on stars that are likely targets for three space-based planet imaging mission concepts studied by NASA—WFIRST-AFTA, Exo-C, and Exo-S. The Doppler targets are primarily F8 and later main sequence stars, with observations spanning 1987-2014. We identified 76 stars with Doppler measurements from the prospective mission target lists. We developed an automated planet search and a methodology to estimate the pipeline completeness using injection and recovery tests. We applied this machinery to the Doppler data and computed planet detection limits for each star as a function of planet minimum mass and semimajor axis. For typical stars in the survey, we are sensitive to approximately Saturn-mass planets inside of 1 au, Jupiter-mass planets inside of ˜3 au, and our sensitivity declines out to ˜10 au. For the best Doppler targets, we are sensitive to Neptune-mass planets in 3 au orbits. Using an idealized model of Doppler survey completeness, we forecast the precision of future surveys of non-ideal Doppler targets that are likely targets of imaging missions. Based on observations obtained at the W. M. Keck Observatory, which is operated jointly by the University of California and the California Institute of Technology. Keck time has been granted by NASA, the University of California, and the University of Hawaii.

  10. Clutter filtering influence on blood velocity estimation using speckle tracking.

    Science.gov (United States)

    Fadnes, Solveig; Bjærum, Steinar; Torp, Hans; Lovstakken, Lasse

    2015-12-01

    Blood speckle tracking has shown potential for solving the angle-dependency limitation in color flow imaging. However, as clutter filtering is still Doppler-based, flow velocities at near-perpendicular beam-to-flow angles can be severely attenuated. It is shown that the clutter filter also alters the speckle appearance through a decrease in the lateral imaging bandwidth, leading to poorer lateral resolution and thus tracking performance. Interestingly, at perpendicular beam-to-flow angles lateral band-pass characteristics are inferred, and the resulting lateral amplitude modulation could help improve tracking estimates. Simulations and flow phantom experiments showed that substantially improved results could be achieved by utilizing time-variant clutter filters (e.g., polynomial regression filters) despite the inherent decorrelation inferred by these filters, but only for higher ensemble sizes (N > 36). We found that, compared with color flow imaging, speckle tracking could yield consistent estimates well below the clutter filter cutoff, but with a higher variance attributed to the low signalto- noise ratio inferred by filter attenuation. Overall, provided that a low f-number and high ensemble lengths (N approx. > 36) can be used, speckle tracking can consistently provide angle- independent flow velocity estimates, limited only by a lower bound on the flow velocity itself.

  11. Carotid Doppler and transcranial Doppler in diagnosing transient ischemic attack: A healthy control

    Institute of Scientific and Technical Information of China (English)

    Huiling Chen; Jinhua Qiu; Hongying Liu

    2006-01-01

    BACKGROUND: If changes of hemodynamics in internal or external cranial artery and stenosis of atherosclerosis are found early, patients with transient ischemic attack (TIA) may be treated at an early phase so as to prevent and decrease the onset of cerebral infarction. Carotid Doppler can analyze carotid canal wall, hemodynamic properties and stenosis, and changes of plaque morphology; however, transcranial Doppler (TCD)can evaluate vascular stenosis and occlusion and judge collateral circulation in cranium through detecting velocity and direction of blood flow. Can the association of them increase the diagnostic rate of TIA?OBJECTIVE: To evaluate the effect of the association of carotid Doppler and TCD on TIA in internal carotid artery.DESIGN: Contrast observational study.SETTING: Department of Neuroelectrophysiology, Central People's Hospital of Huizhou.PARTICIPANTS: A total of 54 patients with TIA in internal carotid artery were selected from the Department of Neurology of Huizhou Central People's Hospital from May 2004 to June 2005. There were 35 males and 24 females aged 46-81 years. The clinical situation was asthenia of single limb, hemiplegia, anaesthesia of single upper or lower limb, hemianesthesia, sensory disorder and aphasia. The symptoms lasted for less than 2 hours. All cases were diagnosed with CT, and those who had pathological changes of acute cerebral infarction and history of cardiac disease were excluded. Additionally, 50 healthy subjects who were regarded as control group were selected from the Department of Neurology of Huizhou Central People's Hospital. There were 30 males and 20 females aged 45-80 years. All subjects were consent.METHODS: HD15000 color Doppler ultrasound (Philips Company, USA) and Muliti-DopX2 TCD (DWL Company, Germany) were used to detect hemodynamics, stenosis and distribution of atherosclerosis in carotid artery and internal carotid artery. Evaluation of marker: Stenosis was calculated by the ratio between the minimal

  12. Influence of oxygen tension on myocardial performance. Evaluation by tissue Doppler imaging

    Directory of Open Access Journals (Sweden)

    Poulsen Steen

    2004-11-01

    Full Text Available Abstract Background Low O2 tension dilates coronary arteries and high O2 tension is a coronary vasoconstrictor but reports on O2-dependent effects on ventricular performance diverge. Yet oxygen supplementation remains first line treatment in cardiovascular disease. We hypothesized that hypoxia improves and hyperoxia worsens myocardial performance. Methods Seven male volunteers (mean age 38 ± 3 years were examined with echocardiography at respiratory equilibrium during: 1 normoxia (≈21% O2, 79% N2, 2 while inhaling a hypoxic gas mixture (≈11% O2, 89% N2, and 3 while inhaling 100% O2. Tissue Doppler recordings were acquired in the apical 4-chamber, 2-chamber, and long-axis views. Strain rate and tissue tracking displacement analyses were carried out in each segment of the 16-segment left ventricular model and in the basal, middle and apical portions of the right ventricle. Results Heart rate increased with hypoxia (68 ± 4 bpm at normoxia vs. 79 ± 5 bpm, P Conclusion Hypoxia improves and hyperoxia worsens systolic myocardial performance in healthy male volunteers. Tissue Doppler measures of diastolic function are unaffected by hypoxia/hyperoxia which support that the changes in myocardial performance are secondary to changes in vascular tone. It remains to be settled whether oxygen therapy to patients with heart disease is a consistent rational treatment.

  13. Comparative of signal processing techniques for micro-Doppler signature extraction with automotive radar systems

    Science.gov (United States)

    Rodriguez-Hervas, Berta; Maile, Michael; Flores, Benjamin C.

    2014-05-01

    In recent years, the automotive industry has experienced an evolution toward more powerful driver assistance systems that provide enhanced vehicle safety. These systems typically operate in the optical and microwave regions of the electromagnetic spectrum and have demonstrated high efficiency in collision and risk avoidance. Microwave radar systems are particularly relevant due to their operational robustness under adverse weather or illumination conditions. Our objective is to study different signal processing techniques suitable for extraction of accurate micro-Doppler signatures of slow moving objects in dense urban environments. Selection of the appropriate signal processing technique is crucial for the extraction of accurate micro-Doppler signatures that will lead to better results in a radar classifier system. For this purpose, we perform simulations of typical radar detection responses in common driving situations and conduct the analysis with several signal processing algorithms, including short time Fourier Transform, continuous wavelet or Kernel based analysis methods. We take into account factors such as the relative movement between the host vehicle and the target, and the non-stationary nature of the target's movement. A comparison of results reveals that short time Fourier Transform would be the best approach for detection and tracking purposes, while the continuous wavelet would be the best suited for classification purposes.

  14. Reduction of Doppler effect for the needs of wayside condition monitoring system of railway vehicles

    Science.gov (United States)

    Dybała, Jacek; Radkowski, Stanisław

    2013-07-01

    Technology of acoustic condition monitoring of vehicles in motion is based on the assumption that diagnostically relevant information is stored in the acoustic signal generated by a passing vehicle. Analyzing the possibilities of increasing the effectiveness of condition monitoring of a passing vehicle with stationary microphones, it should be noted that the acoustic signal recorded in these conditions is disturbed with the disturbance resulting from the Doppler effect. Reduction of signal's frequential structure disturbance resulting from the Doppler effect allows efficient analysis of changes in frequential structure of recorded signals and as a result extraction of relevant diagnostic information related with technical condition of running gear of vehicle. This article presents a method for removal of signal's frequential structure disturbances related with relative move of vehicles and stationary monitoring station. For elimination of the frequential non-stationary of signals disturbance-oriented dynamic signal resampling method was used. The paper provides a test of two methods for defining the time course of local disturbance of signal's frequential structure: the method based on the Hilbert transform and the method of analytical description of signal's disturbance based on the knowledge of a phenomenon that causes frequential non-stationarity of signals. As an example, the results of the processing and analysis of acoustic signals recorded by wayside measuring station, during the passage of WM-15A railway vehicle on an experimental track of Polish Railway Institute, are presented.

  15. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Beaver, W. L.; Meindl, J. D.

    1976-01-01

    Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.

  16. Interferometric millimeter wave and THz wave doppler radar

    Science.gov (United States)

    Liao, Shaolin; Gopalsami, Nachappa; Bakhtiari, Sasan; Raptis, Apostolos C.; Elmer, Thomas

    2015-08-11

    A mixerless high frequency interferometric Doppler radar system and methods has been invented, numerically validated and experimentally tested. A continuous wave source, phase modulator (e.g., a continuously oscillating reference mirror) and intensity detector are utilized. The intensity detector measures the intensity of the combined reflected Doppler signal and the modulated reference beam. Rigorous mathematics formulas have been developed to extract bot amplitude and phase from the measured intensity signal. Software in Matlab has been developed and used to extract such amplitude and phase information from the experimental data. Both amplitude and phase are calculated and the Doppler frequency signature of the object is determined.

  17. Processor operated correlator with applications to laser Doppler signals

    DEFF Research Database (Denmark)

    Bisgaard, C.; Johnsen, B.; Hassager, Ole

    1984-01-01

    A 64-channel correlator is designed with application to the processing of laser Doppler anemometry signals in the range 200 Hz to 250 kHz. The correlator is processor operated to enable the consecutive sampling of 448 correlation functions at a rate up to 500 Hz. Software is described to identify...... a Doppler frequency from each correlation and the system is especially designed for transient flow signals. Doppler frequencies are determined with an accuracy of about 0.1%. Review of Scientific Instruments is copyrighted by The American Institute of Physics....

  18. Mitigating Doppler shift effect in HF multitone data modem

    Science.gov (United States)

    Sonlu, Yasar

    1989-09-01

    Digital communications over High Frequency (HF) radio channels are getting important in recent years. Current HF requirements are for data transmission at rates 2.4 kbps or more to accommodate computer data links and digital secure voice. HF modems which were produced to meet these speeds are, serial modems and parallel modems. On the other hand, the HF sky-wave communication medium, the ionosphere, has some propagation problems such as multipath and Doppler shift. The effect of Doppler shift in a parallel modem which employs Differential Quadrature Phase Shift Keying (DQPSK) modulation is considered and a correction method to mitigate the Doppler Shift effect is introduced.

  19. Computer simulation studies of pulsed Doppler signals from vortices

    Institute of Scientific and Technical Information of China (English)

    CHEN Sizhong; WANG Yuanyuan; WANG Weiqi

    2001-01-01

    A computer simulation method for pulsed Doppler signals from vortices was proposed to generate simulated vortex Doppler signals under various given circumstances. The relative waveforms, such as the maximum frequency waveform, the mean frequency waveform and the bandwidth waveform, were obtained using the short time Fourier analysis of those simulated signals. The relations were studied between several spectrum parameters obtained from these waveforms and given simulation conditions, such as the position and the size of the sample volume, the distance between two vortices, the free stream velocity and the maximum tangent velocity of the vortex. The sensitive parameters were found to detect vortices using the pulsed Doppler techniques.

  20. Automatic extraction of disease-specific features from Doppler images

    Science.gov (United States)

    Negahdar, Mohammadreza; Moradi, Mehdi; Parajuli, Nripesh; Syeda-Mahmood, Tanveer

    2017-03-01

    Flow Doppler imaging is widely used by clinicians to detect diseases of the valves. In particular, continuous wave (CW) Doppler mode scan is routinely done during echocardiography and shows Doppler signal traces over multiple heart cycles. Traditionally, echocardiographers have manually traced such velocity envelopes to extract measurements such as decay time and pressure gradient which are then matched to normal and abnormal values based on clinical guidelines. In this paper, we present a fully automatic approach to deriving these measurements for aortic stenosis retrospectively from echocardiography videos. Comparison of our method with measurements made by echocardiographers shows large agreement as well as identification of new cases missed by echocardiographers.

  1. An Adaptive Channel Interpolator Based on Kalman Filter for LTE Uplink in High Doppler Spread Environments

    Directory of Open Access Journals (Sweden)

    Arslan Hüseyin

    2009-01-01

    Full Text Available Long-Term Evolution (LTE systems will employ single carrier frequency division multiple access (SC-FDMA for the uplink. Similar to the Orthogonal frequency-division multiple access (OFDMA technology, SC-FDMA is sensitive to frequency offsets leading to intercarrier interference (ICI. In this paper, we propose a Kalman filter-based approach in order to mitigate ICI under high Doppler spread scenarios by tracking the variation of channel taps jointly in time domain for LTE uplink systems. Upon acquiring the estimates of channel taps from the Kalman tracker, we employ an interpolation algorithm based on polynomial fitting whose order is changed adaptively. The proposed method is evaluated under four different scenarios with different settings in order to reflect the impact of various critical parameters on the performance such as propagation environment, speed, and size of resource block (RB assignments. Results are given along with discussions.

  2. Effect of sample volume size and sampling method on feline longitudinal myocardial velocity profiles from color tissue Doppler imaging.

    Science.gov (United States)

    Granström, Sara; Pipper, Christian Bressen; Møgelvang, Rasmus; Sogaard, Peter; Willesen, Jakob Lundgren; Koch, Jørgen

    2012-12-01

    The aims of this study were to compare the effect of sample volume (SV) size settings and sampling method on measurement variability and peak systolic (s'), and early (e') and late (a') diastolic longitudinal myocardial velocities using color tissue Doppler imaging (cTDI) in cats. Twenty cats with normal echocardiograms and 20 cats with hypertrophic cardiomyopathy. We quantified and compared empirical variance and average absolute values of s', e' and a' for three cardiac cycles using eight different SV settings (length 1,2,3 and 5 mm; width 1 and 2 mm) and three methods of sampling (end-diastolic sampling with manual tracking of the SV, end-systolic sampling without tracking, and random-frame sampling without tracking). No significant difference in empirical variance could be demonstrated between most of the tested SVs. However, the two settings with a length of 1 mm resulted in a significantly higher variance compared with all settings where the SV length exceeded 2 mm (p sampling method on the variability of measurements (p = 0.003) and manual tracking obtained the lowest variance. No difference in average values of s', e' or a' could be found between any of the SV settings or sampling methods. Within the tested range of SV settings, an SV length of 1 mm resulted in higher measurement variability compared with an SV length of 3 and 5 mm, and should therefore be avoided. Manual tracking of the sample volume is recommended. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. The Next Generation Airborne Polarimetric Doppler Radar

    Science.gov (United States)

    Vivekanandan, J.; Lee, Wen-Chau; Loew, Eric; Salazar, Jorge; Chandrasekar, V.

    2013-04-01

    NCAR's Electra Doppler radar (ELDORA) with a dual-beam slotted waveguide array using dual-transmitter, dual-beam, rapid scan and step-chirped waveform significantly improved the spatial scale to 300m (Hildebrand et al. 1996). However, ELDORA X-band radar's penetration into precipitation is limited by attenuation and is not designed to collect polarimetric measurements to remotely estimate microphysics. ELDORA has been placed on dormancy because its airborne platform (P3 587) was retired in January 2013. The US research community has strongly voiced the need to continue measurement capability similar to the ELDORA. A critical weather research area is quantitative precipitation estimation/forecasting (QPE/QPF). In recent years, hurricane intensity change involving eye-eyewall interactions has drawn research attention (Montgomery et al., 2006; Bell and Montgomery, 2006). In the case of convective precipitation, two issues, namely, (1) when and where convection will be initiated, and (2) determining the organization and structure of ensuing convection, are key for QPF. Therefore collocated measurements of 3-D winds and precipitation microphysics are required for achieving significant skills in QPF and QPE. Multiple radars in dual-Doppler configuration with polarization capability estimate dynamical and microphysical characteristics of clouds and precipitation are mostly available over land. However, storms over complex terrain, the ocean and in forest regions are not observable by ground-based radars (Bluestein and Wakimoto, 2003). NCAR/EOL is investigating potential configurations for the next generation airborne radar that is capable of retrieving dynamic and microphysical characteristics of clouds and precipitation. ELDORA's slotted waveguide array radar is not compatible for dual-polarization measurements. Therefore, the new design has to address both dual-polarization capability and platform requirements to replace the ELDORA system. NCAR maintains a C-130

  4. Tracking of supergranules - Does it make any sense?

    CERN Document Server

    Svanda, M; Sobotka, M

    2008-01-01

    The motions of the plasma and structures in and below the solar photosphere is not well understood. The results obtained using various methods cannot be in general considered as consistent, especially in details. In this contribution we show a summary of the results obtained by the method we have developed recently. To study the photospheric dynamics we apply the local correlation tracking algorithm to the series of full-disc Dopplergrams obtained by Michelson Doppler Imager (MDI) aboard the SOHO satelite. The dominant structure recorded in Dopplergrams is the supergranulation. Under the assumtion that the supergranules are carried by the flow field of the larger scale, we study properties of this underlying velocity field. We perform comparative tests with synthetic data with known properties and with results of the time-distance helioseismology with a great success. A few case studies are shown to demonstrate the performance of the method. We believe that tracking of supergranules makes a perfect sense when...

  5. Human Capital Tracking Tool -

    Data.gov (United States)

    Department of Transportation — AVS is now required to collect, track, and report on data from the following Flight, Business and Workforce Plan. The Human Resource Management’s Performance Target...

  6. Track Loading Vehicle - TLV

    Data.gov (United States)

    Federal Laboratory Consortium — The TLV is designed to apply forces close to the strength limits of the rails and other track structure components, such as ties, rail fasteners, and ballast, while...

  7. 1996 : Track Count Protocol

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The goal of St. Vincent National Wildlife Refuge's Track Count Protocol is to provide an index to the population size of game animals inhabiting St. Vincent Island.

  8. Case Analysis Tracking System

    Data.gov (United States)

    National Archives and Records Administration — CATS tracks Public and Federal Agency Reference Requests for OPF (Official Personnel Folder) , EMF (Employee Medical Folder), and eOPF (electronic Official Personnel...

  9. Financial Disclosure Tracking System

    Data.gov (United States)

    US Agency for International Development — USAID's FDTS identifies personal service contractors and local employees who should file disclosure reports. It tracks late filers and identifies those who must take...

  10. Matter Tracking Information System -

    Data.gov (United States)

    Department of Transportation — The Matter Tracking Information System (MTIS) principle function is to streamline and integrate the workload and work activity generated or addressed by our 300 plus...

  11. Neonate turtle tracking data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The objectives of this project are to use novel satellite tracking methods to provide improved estimation of threats at foraging areas and along migration routes for...

  12. LHCb on track

    CERN Multimedia

    2006-01-01

    On 7 and 8 June 2006, the last large component of the LHCb experiment was lowered into the cavern. This 10-tonne, 18-metre long metal structure known as 'the bridge' will support the LHCb tracking system.

  13. Patient Treatment Tracking Chart

    Science.gov (United States)

    ... Treatment Tracking Chart Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For Veterans and the Public Veterans ... can record dates of blood work, laboratory values, hepatitis C viral load levels, medication dosages, and side effects. You ...

  14. Energy Tracking Software Platform

    Energy Technology Data Exchange (ETDEWEB)

    Ryan Davis; Nathan Bird; Rebecca Birx; Hal Knowles

    2011-04-04

    Acceleration has created an interactive energy tracking and visualization platform that supports decreasing electric, water, and gas usage. Homeowners have access to tools that allow them to gauge their use and track progress toward a smaller energy footprint. Real estate agents have access to consumption data, allowing for sharing a comparison with potential home buyers. Home builders have the opportunity to compare their neighborhood's energy efficiency with competitors. Home energy raters have a tool for gauging the progress of their clients after efficiency changes. And, social groups are able to help encourage members to reduce their energy bills and help their environment. EnergyIT.com is the business umbrella for all energy tracking solutions and is designed to provide information about our energy tracking software and promote sales. CompareAndConserve.com (Gainesville-Green.com) helps homeowners conserve energy through education and competition. ToolsForTenants.com helps renters factor energy usage into their housing decisions.

  15. Tracking Performance at LHCb

    CERN Multimedia

    Wandernoth, S

    2010-01-01

    We present the tracking performance at LHCb by showing the mass resolution, impact parameter resolution and proper time resolution of the first data taken at LHCb. Furthermore several methods to estimate the tagging efficiency on data are presented.

  16. Procurement Tracking System (PTS)

    Data.gov (United States)

    Office of Personnel Management — The Procurement Tracking System (PTS) is used solely by the procurement staff of the Office of the Inspector General (OIG) at the U.S. Office of Personnel Management...

  17. LHCb VELO Tracking Resolutions

    CERN Multimedia

    Alexander, Michael

    2011-01-01

    The excellent tracking performance of the Vertex Locator (VELO) at LHCb is presented. The resolutions it achieves on single hits, impact parameters, and primary vertex positions are shown, with particular attention paid to measurement of impact parameters.

  18. Applied eye tracking research

    NARCIS (Netherlands)

    Jarodzka, Halszka

    2011-01-01

    Jarodzka, H. (2010, 12 November). Applied eye tracking research. Presentation and Labtour for Vereniging Gewone Leden in oprichting (VGL i.o.), Heerlen, The Netherlands: Open University of the Netherlands.

  19. Jet Car Track Site

    Data.gov (United States)

    Federal Laboratory Consortium — Located in Lakehurst, New Jersey, the Jet Car Track Site supports jet cars with J57 engines and has a maximum jet car thrust of 42,000 pounds with a maximum speed of...

  20. Applied eye tracking research

    NARCIS (Netherlands)

    Jarodzka, Halszka

    2011-01-01

    Jarodzka, H. (2010, 12 November). Applied eye tracking research. Presentation and Labtour for Vereniging Gewone Leden in oprichting (VGL i.o.), Heerlen, The Netherlands: Open University of the Netherlands.

  1. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    Science.gov (United States)

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M

    2015-11-01

    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation.

  2. Estimation of amputation level with a laser Doppler flowmeter

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Jørgensen, J P; Vollmer-Larsen, B;

    1989-01-01

    Leg amputation levels were decided in 24 patients suffering from atherosclerosis, using the conventional techniques of segmental blood pressure and radioisotope skin clearance. The skin microcirculation was measured and recorded before operation with a laser doppler flowmeter. A high correlation ...

  3. Doppler Signatures of the Atmospheric Circulation on Hot Jupiters

    CERN Document Server

    Showman, Adam P; Lewis, Nikole K; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation--and Doppler signature--of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blue- and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps...

  4. Doppler bubble detection and decompression sickness: a prospective clinical trial.

    Science.gov (United States)

    Bayne, C G; Hunt, W S; Johanson, D C; Flynn, E T; Weathersby, P K

    1985-09-01

    Decompression sickness in human beings exposed to high ambient pressure is thought to follow from gas bubble formation and growth in the body during return to low pressure. Detection of Doppler-shifted ultrasonic reflections in major blood vessels has been promoted as a noninvasive and sensitive indicator of the imminence of decompression sickness. We have conducted a double-blind, prospective clinical trial of Doppler ultrasonic bubble detection in simulated diving using 83 men, of whom 8 were stricken and treated for the clinical disease. Diagnosis based only on the Doppler signals had no correlation with clinical diagnosis. Bubble scores were only slightly higher in the stricken group. The Doppler technique does not appear to be of diagnostic value in the absence of other clinical information.

  5. Doppler electron velocimetry : notes on creating a practical tool.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.; Milster, Tom (University of Arizona)

    2008-11-01

    The Doppler electron velocimeter (DEV) has been shown to be theoretically possible. This report attempts to answer the next logical question: Is it a practical instrument? The answer hinges upon whether enough electrons are available to create a time-varying Doppler current to be measured by a detector with enough sensitivity and bandwidth. The answer to both of these questions is a qualified yes. A target Doppler frequency of 1 MHz was set as a minimum rate of interest. At this target a theoretical beam current signal-to-noise ratio of 25-to-1 is shown for existing electron holography equipment. A detector is also demonstrated with a bandwidth of 1-MHz at a current of 10 pA. Additionally, a Linnik-type interferometer that would increase the available beam current is shown that would offer a more flexible arrangement for Doppler electron measurements over the traditional biprism.

  6. Aliasing-tolerant color Doppler quantification of regurgitant jets.

    Science.gov (United States)

    Stewart, S F

    1998-07-01

    Conservation of momentum transfer in regurgitant cardiac jets can be used to calculate the flow rate from color Doppler velocities. In this study, turbulent jets were simulated by finite elements; pseudocolor Doppler images were interpolated from the computations, with aliasing introduced artificially. Jets were also imaged by color Doppler in an in vitro flow system. To suppress aliasing errors, jet velocities were fitted iteratively to a fluid mechanical model constrained to match the orifice velocity (measured without aliasing by continuous-wave Doppler). At each iteration, the model was used to detect aliased velocities, which were excluded during the next iteration. Iteration continued until the flow rate calculated by the model and number of calculated nonaliased pixels were unchanged. The good correlations between measured and calculated flow rates in the experimental (R2 = 0.933) and computational studies (R2 = 0.990) suggest that this may be a clinically useful approach even in aliased images. Published by Elsevier Science Inc.

  7. Micro-Doppler processing for ultra-wideband radar data

    Science.gov (United States)

    Smith, Graeme E.; Ahmad, Fauzia; Amin, Moeness G.

    2012-06-01

    In this paper, we describe an operational pulse Doppler radar imaging system for indoor target localization and classification, and show how a target's micro-Doppler signature (μDS) can be processed when ultra-wideband (UWB) waveforms are employed. Unlike narrowband radars where time-frequency signal representations can be applied to reveal the target time-Doppler frequency signatures, the UWB system permits joint range-time-frequency representation (JRTFR). JRTFR outputs the data in a 3D domain representing range, frequency, and time, allowing both the μDS and high range resolution (HRR) signatures to be observed. We delineate the relationship between the μDS and the HRR signature, showing how they would form a complimentary joint feature for classification. We use real-data to demonstrate the effectiveness of the UWB pulse-Doppler radar, combined with nonstationary signal analyses, in gaining valuable insights into human positioning and motions.

  8. Millimeter-wave micro-Doppler measurements of small UAVs

    Science.gov (United States)

    Rahman, Samiur; Robertson, Duncan A.

    2017-05-01

    This paper discusses the micro-Doppler signatures of small UAVs obtained from a millimeter-wave radar system. At first, simulation results are shown to demonstrate the theoretical concept. It is illustrated that whilst the propeller rotation rate of the small UAVs is quite high, millimeter-wave radar systems are capable of capturing the full micro-Doppler spread. Measurements of small UAVs have been performed with both CW and FMCW radars operating at 94 GHz. The CW radar was used for obtaining micro-Doppler signatures of individual propellers. The field test data of a flying small UAV was collected with the FMCW radar and was processed to extract micro-Doppler signatures. The high fidelity results clearly reveal features such as blade flashes and propeller rotation modulation lines which can be used to classify targets. This work confirms that millimeter-wave radar is suitable for the detection and classification of small UAVs at usefully long ranges.

  9. Extracting and analyzing micro-Doppler from ladar signatures

    Science.gov (United States)

    Tahmoush, Dave

    2015-05-01

    Ladar and other 3D imaging modalities have the capability of creating 3D micro-Doppler to analyze the micro-motions of human subjects. An additional capability to the recognition of micro-motion is the recognition of the moving part, such as the hand or arm. Combined with measured RCS values of the body, ladar imaging can be used to ground-truth the more sensitive radar micro-Doppler measurements and associate the moving part of the subject with the measured Doppler and RCS from the radar system. The 3D ladar signatures can also be used to classify activities and actions on their own, achieving an 86% accuracy using a micro-Doppler based classification strategy.

  10. The Doppler Effect: A Consideration of Quasar Redshifts.

    Science.gov (United States)

    Gordon, Kurtiss J.

    1980-01-01

    Provides information on the calculation of the redshift to blueshift ratio introduced by the transverse Doppler effect at relativistic speeds. Indicates that this shift should be mentioned in discussions of whether quasars are "local" rather than "cosmological" objects. (GS)

  11. Doppler Ambiguity Resolution Based on Random Sparse Probing Pulses

    Directory of Open Access Journals (Sweden)

    Yunjian Zhang

    2015-01-01

    Full Text Available A novel method for solving Doppler ambiguous problem based on compressed sensing (CS theory is proposed in this paper. A pulse train with the random and sparse transmitting time is transmitted. The received signals after matched filtering can be viewed as randomly sparse sampling from the traditional fixed-pulse repetition frequency (PRF echo signals. The whole target echo could be reconstructed via CS recovery algorithms. Through refining the sensing matrix, which is equivalent to increase the sampling frequency of target characteristic, the Doppler unambiguous range is enlarged. In particular, Complex Approximate Message Passing (CAMP algorithm is developed to estimate the unambiguity Doppler frequency. Cramer-Rao lower bound expressions are derived for the frequency. Numerical simulations validate the effectiveness of the proposed method. Finally, compared with traditional methods, the proposed method only requires transmitting a few sparse probing pulses to achieve a larger Doppler frequency unambiguous range and can also reduce the consumption of the radar time resources.

  12. [Postpartal ovarian thrombophlebitis. Value of Doppler ultrasonograph y].

    Science.gov (United States)

    Renaud-Giono, A; Giraud, J R; Poulain, P; Proudhon, J F; Grall, J Y; Moquet, P Y; Darnault, J P

    1996-01-01

    Thrombophlebitis of the ovarian vein is a well recognized but uncommon complication during the postpartum period. We report a small series and emphasize the contribution of color Doppler and the basic therapeutic measures.

  13. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003775.htm Doppler ultrasound exam of an arm or leg To use ... this page, please enable JavaScript. This test uses ultrasound to look at the blood flow in the ...

  14. Analysis of multiple scattering effects in optical Doppler tomography

    DEFF Research Database (Denmark)

    Yura, H.T.; Thrane, L.; Andersen, Peter E.

    2005-01-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where...... multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed...... Doppler frequency spectrum. Thus, in the present analysis, the dependence of the mean and standard deviation of the Doppler shift on the scattering properties of the flowing medium are obtained. Taking the multiple scattering effects into account, we are able to explain previous measurements of depth...

  15. Multiplexed sub-Doppler spectroscopy with an optical frequency comb

    CERN Document Server

    Long, David A; Plusquellic, David F; Hodges, Joseph T

    2016-01-01

    An optical frequency comb generated with an electro-optic phase modulator and a chirped radiofrequency waveform is used to perform saturation and pump-probe spectroscopy on the $D_1$ and $D_2$ transitions of atomic potassium. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be simultaneously observed. Interferograms are recorded in as little as 5 $\\mu$s (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.

  16. COLOR DOPPLER ULTRASOUND IN EVALUATION OF SCROTAL LESIONS

    Directory of Open Access Journals (Sweden)

    Desai Sanjay

    2015-11-01

    Full Text Available : Color Doppler ultrasound is a non-invasive, non-ionising and rapid method for scrotal examination. The present study is carried out to evaluate clinically suspected cases of scrotal lesions, the sensitivity, specificity of color doppler. MATERIAL AND METHODS: This prospective study comprises 120 patients of different age groups with clinical suspicion of scrotal lesions. Color doppler ultrasound was done with 7.5MHz transducer. RESULTS: Of the total 120 cases, benign conditions 111 (92.5% is more common than malignant 9 (7.5%. In benign group commonest diagnoses were hydrocele, epididymo-orchitis, varicocele and epididymal cyst. In malignant group teratocarcinoma, choriocarcinoma, seminoma, lymphoma, embryonal cell carcinoma, yolk sac tumor with teratocarcinoma. The sensitivity for diagnosing extratesticular lesions was 83.14% and for testicular lesions 88.57%. CONCLUSION: Color doppler ultrasound is helpful in differentiating extratesticular and intratesticular lesions. It should be performed in all patients with suspected scrotal lesions

  17. The Doppler Effect: A Consideration of Quasar Redshifts.

    Science.gov (United States)

    Gordon, Kurtiss J.

    1980-01-01

    Provides information on the calculation of the redshift to blueshift ratio introduced by the transverse Doppler effect at relativistic speeds. Indicates that this shift should be mentioned in discussions of whether quasars are "local" rather than "cosmological" objects. (GS)

  18. Design of new seismometer based on laser Doppler effect

    Institute of Scientific and Technical Information of China (English)

    Zhenhui Du(杜振辉); Fuxiang Huang(黄福祥); Chengzhi Jiang(蒋诚志); Zhifei Tao(陶知非); Hua Gao(高华); Lina Lü(吕丽娜)

    2004-01-01

    In order to improve the resolution of seismic acquisition, a new seismic acquisition system based on tangential laser Doppler effect with an optimized differential optical configuration is proposed. The relative movement of the inertia object and the immobile frame is measured by laser Doppler effect, which can avoid the electromagnetic and thermometric interference, and the adoption of frequency-modulated (FM)transmission can improve the ability of anti-jamming. The frequency bandwidth is properly determined by analyzing the frequency of the Doppler signal. The velocity, displacement, acceleration, and frequency to be measured can be real-time acquired by frequency/velocity (F/V) converting the FM Doppler signal.A 100-dB dynamic range and the linear frequency range of 1.0 to 1000 Hz are realized.

  19. Doppler Compensation by using of Segmented Match Filter

    Directory of Open Access Journals (Sweden)

    Nader Ghadimi

    2008-09-01

    Full Text Available Match filter is one of the important parts of radar receiver. By using of Match Filter, the signal to noise ratio can be maximized so that the probability of detection is increased. Match Filter can be used as a pulse compression filter in radar receiver. Binary phase code is one of the pulse compression methods that, the compression can be down with a Match Filter in the receiver. Doppler effect is one of the problems that degrade the performance of Match Filter. In this paper, two methods “Mixer Array” and “Segmented Match Filter” are proposed for Doppler compensation. The operation of these two methods as Doppler compensation techniques are considered theoretically. The simulation is used to demonstrate the Doppler compensation performance of new techniques compared to conventional methods.

  20. Methodology for obtaining wind gusts using Doppler lidar

    DEFF Research Database (Denmark)

    Suomi, Irene; Gryning, Sven-Erik; O'Connor, Ewan J.

    2017-01-01

    . This novel method also provides estimates for wind gusts at arbitrary gust durations, including those shorter than the temporal resolution of the Doppler lidar measurements. The input parameters for the scaling method are the measured wind-gust speed as well as the mean and standard deviation...... of the horizontal wind speed. The method was tested using WindCube V2 Doppler lidar measurements taken next to a 100 m high meteorological mast. It is shown that the method can provide realistic Doppler lidar estimates of the gust factor, i.e. the ratio of the wind-gust speed to the mean wind speed. The method...... speed. To assure the data quality in this study, we applied a filtering technique based on spike detection to remove possible outliers in the Doppler lidar data. We found that the spike detection-removal method clearly improved the wind-gust measurements, both with and without the scaling method. Spike...

  1. Function integrated track system

    OpenAIRE

    Hohnecker, Eberhard

    2010-01-01

    The paper discusses a function integrated track system that focuses on the reduction of acoustic emissions from railway lines. It is shown that the combination of an embedded rail system (ERS), a sound absorbing track surface, and an integrated mini sound barrier has significant acoustic advantages compared to a standard ballast superstructure. The acoustic advantages of an embedded rail system are particularly pronounced in the case of railway bridges. Finally, it is shown that a...

  2. Vehicle Tracking and Security

    Science.gov (United States)

    Scorer, A. G.

    1998-09-01

    This paper covers the wide area and short range locational technologies that are available for vehicle tracking in particular and mobile user security in general. It also summarises the radio communications services that can deliver information to the user. It considers the use that can be made of these technologies, when combined with procedures for delivering a response, in the security field, notably in relation to personal security, high-value load protection and the after-theft tracking markets.

  3. Provenance Tracking in UNICORE

    OpenAIRE

    Giesler, André; Hagemeier, Björn; Czekala, Myriam

    2015-01-01

    The automated tracking and storage of provenance information allows users of scientific workflow systems to validate and reproduce results of their experiments. Until now, UNICORE has not been providing comprehensive provenance features. For this reason, we plan to equip UNICORE with a flexible provenance tracking mechanism. Our goal is to ensure a suitable traceability of job and workflow processes into a description format supporting query capabilities and interoperability. In a first step,...

  4. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  5. MATERIAL TRACKING USING LANMAS

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, F.

    2010-06-07

    LANMAS is a transaction-based nuclear material accountability software product developed to replace outdated and legacy accountability systems throughout the DOE. The core underlying purpose of LANMAS is to track nuclear materials inventory and report transactions (movement, mixing, splitting, decay, etc.) to the Nuclear Materials Management and Safeguards System (NMMSS). While LANMAS performs those functions well, there are many additional functions provided by the software product. As a material is received onto a site or created at a site, its entire lifecycle can be tracked in LANMAS complete to its termination of safeguards. There are separate functions to track material movements between and within material balance areas (MBAs). The level of detail for movements within a MBA is configurable by each site and can be as high as a site designation or as detailed as building/room/rack/row/position. Functionality exists to track the processing of materials, either as individual items or by modeling a bulk process as an individual item to track inputs and outputs from the process. In cases where sites have specialized needs, the system is designed to be flexible so that site specific functionality can be integrated into the product. This paper will demonstrate how the software can be used to input material into an account and track it to its termination of safeguards.

  6. Quantification of cardiac blood flow by Doppler technique

    OpenAIRE

    Meijboom, Erik Jan

    1985-01-01

    textabstractThe investigations described in this thesis started as part of the research program of the divisions of pediatric cardiology of the Universities of Arizona and California (San Diego). The investigations were part of an ongoing project designed by D.J. Sahn and L.M. Valdes-Cruz. This project was initiated to implement Doppler techniques in the daily practice of pediatric cardiology. New developments in medical technology made the Doppler techniques integrated into sophisticated two...

  7. Monitoring and Analysis of Respiratory Patterns Using Microwave Doppler Radar

    Science.gov (United States)

    Pathirana, Pubudu N.; Steinfort, Christopher Louis; Caelli, Terry

    2014-01-01

    Noncontact detection characteristic of Doppler radar provides an unobtrusive means of respiration detection and monitoring. This avoids additional preparations, such as physical sensor attachment or special clothing, which can be useful for certain healthcare applications. Furthermore, robustness of Doppler radar against environmental factors, such as light, ambient temperature, interference from other signals occupying the same bandwidth, fading effects, reduce environmental constraints and strengthens the possibility of employing Doppler radar in long-term respiration detection, and monitoring applications such as sleep studies. This paper presents an evaluation in the of use of microwave Doppler radar for capturing different dynamics of breathing patterns in addition to the respiration rate. Although finding the respiration rate is essential, identifying abnormal breathing patterns in real-time could be used to gain further insights into respiratory disorders and refine diagnostic procedures. Several known breathing disorders were professionally role played and captured in a real-time laboratory environment using a noncontact Doppler radar to evaluate the feasibility of this noncontact form of measurement in capturing breathing patterns under different conditions associated with certain breathing disorders. In addition to that, inhalation and exhalation flow patterns under different breathing scenarios were investigated to further support the feasibility of Doppler radar to accurately estimate the tidal volume. The results obtained for both experiments were compared with the gold standard measurement schemes, such as respiration belt and spirometry readings, yielding significant correlations with the Doppler radar-based information. In summary, Doppler radar is highlighted as an alternative approach not only for determining respiration rates, but also for identifying breathing patterns and tidal volumes as a preferred nonwearable alternative to the conventional

  8. Radar target recognition based on micro-Doppler effect

    Institute of Scientific and Technical Information of China (English)

    DONG Wei-guang; LI Yan-jun

    2008-01-01

    Mechanical vibration of target structures will modulate the phase function of radar backscattering, and will induce thefrequency modulation of returned signals from the target. It generates a side bands of the target body Doppler frequencyshift, which is helpful for target recognition. Based on this.a micro-Doppler atomic storehouse is built for the targetrecognition, and four kinds of common classifiers are used separately to perform the classified recognition. The simulationexperimental results show that this method has high recognition rate above 90%.

  9. Using doppler radar images to estimate aircraft navigational heading error

    Science.gov (United States)

    Doerry, Armin W [Albuquerque, NM; Jordan, Jay D [Albuquerque, NM; Kim, Theodore J [Albuquerque, NM

    2012-07-03

    A yaw angle error of a motion measurement system carried on an aircraft for navigation is estimated from Doppler radar images captured using the aircraft. At least two radar pulses aimed at respectively different physical locations in a targeted area are transmitted from a radar antenna carried on the aircraft. At least two Doppler radar images that respectively correspond to the at least two transmitted radar pulses are produced. These images are used to produce an estimate of the yaw angle error.

  10. Doppler visibility of coherent random noise radar systems

    Science.gov (United States)

    Li, Zhixi; Narayanan, Ram M.

    2005-05-01

    Random noise radar has recently been used in a variety of imaging and surveillance applications. These systems can be made phase coherent using the technique of heterodyne correlation. Phase coherence has been exploited to measure Doppler and thereby the velocity of moving targets. The Doppler visibility, i.e., the ability to extract Doppler information over the inherent clutter spectra, is constrained by system parameters, especially the phase noise generated by microwave components. Our paper proposes a new phase noise model for the heterodyne mixer as applicable for ultrawideband (UWB) random noise radar and for the local oscillator in the time domain. The Doppler spectra are simulated by including phase noise contamination effects and compared to our previous experimental results. A Genetic Algorithm (GA) optimization routine is applied to synthesize the effects of a variety of parameter combinations to derive a suitable empirical formula for estimating the Doppler visibility in dB. According to the phase noise analysis and the simulation results, the Doppler visibility of UWB random noise radar depends primarily on the following parameters: (a) the local oscillator (LO) drive level of the receiver heterodyne mixer; (b) the saturation current in the receiver heterodyne mixer; (c) the bandwidth of the transmit noise source, and; (d) the target velocity. Other parameters such as the carrier frequency of the receiver LO and the loaded quality factor of the LO have a small effect over the range of applicability of the model and are therefore neglected in the model formulation. The Doppler visibility curves generated from this formula match the simulation results very well over the applicable parameter range within 1 dB. Our model may therefore be used to quickly estimate the Doppler visibility of random noise radars for trade-off analysis.

  11. Single mode, extreme precision Doppler spectrographs

    CERN Document Server

    Schwab, Christian; Betters, Christopher H; Bland-Hawthorn, Joss; Mahadevan, Suvrath

    2012-01-01

    The 'holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a...

  12. Satellite Doppler Fixation and International Boundaries

    Science.gov (United States)

    Leppard, N. A. G.

    1980-01-01

    International boundaries have seldom been completely defined in geodetic terms. The existence of natural resources, which ignore the arbitrary boundaries of man, assume considerable importance when division of those resources becomes a point of issue between potential owners. This is particularly so when the boundary is illdefined in a geodetic sense. World-wide satellite reference systems, like natural resources, also have little regard for the internally less precise national or international systems. When the one is used to define the location of the other, great care must be taken to ensure equitable division, for financial gain and loss can be considerable. The definition of position is complicated by the existence of the two ephemerides for the N.N.S.S. satellites and the number of alternative reduction procedures available. The definition of the position of the Frigg Gas Field in the North Sea is an example of how the United Kingdom and Norway resolved the geodetic problem of reconciling geodetic and Doppler data.

  13. Doppler cooling of a Coulomb crystal

    CERN Document Server

    Morigi, G; Morigi, Giovanna; Eschner, Juergen

    2001-01-01

    We study theoretically Doppler laser-cooling of a cluster of 2-level atoms confined in a linear ion trap. Using several consecutive steps of averaging we derive, from the full quantum mechanical master equation, an equation for the total mechanical energy of the one dimensional crystal, defined on a coarse-grained energy scale whose grid size is smaller than the linewidth of the electronic transition. This equation describes the cooling dynamics for an arbitrary number of ions and in the quantum regime. We discuss the validity of the ergodic assumption (i.e. that the phase space distribution is only a function of energy). From our equation we derive the semiclassical limit (i.e. when the mechanical motion can be treated classically) and the Lamb-Dicke limit (i.e. when the size of the mechanical wave function is much smaller than the laser wavelength). We find a Fokker-Planck equation for the total mechanical energy of the system, whose solution is in agreement with previous analytical calculations which were ...

  14. MEMS characterization using Laser Doppler Vibrometry

    Science.gov (United States)

    Lawrence, Eric M.; Speller, Kevin E.; Yu, Duli

    2003-01-01

    The use of Laser Doppler Vibrometry (LDV) technology has been at the forefront of Micro-Electro-Mechanical Systems (MEMS) research since the early 1990"s. By its nature as a sensitive laser optical technique, it is well suited for non-contact dynamic response measurements of microscopic structures. The art of the technology has culminated into the latest micro-scanning vibrometer for automated scan measurement and display of deflection shapes with sub-nanometer resolution. To exemplify the use of this technology, Polytec PI presents characterization measurements in collaboration with Applied MEMS on two of their devices used in commercial applications. LDV characterization measurements are used for validating the design of the Applied MEMS two-axis micro mirror. Scan measurements reveal distinct, isolated rotation modes about x- and y- axes that can be used to promote the mirror motion in either direction. Settling time performance is evaluated from impulse response and optimized using Input Shaping techniques. Scan measurements of a low-noise accelerometer device from Applied MEMS reveals spurious high frequency modes of support spring causing unwanted response effects. Further use of a new time domain animation feature shows ringing response of the accelerometer to step motions.

  15. Muscle activity characterization by laser Doppler Myography

    Science.gov (United States)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  16. Doppler effect induced spin relaxation boom

    Science.gov (United States)

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-03-01

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures.

  17. Zeeman Doppler Maps: Always Unique, Never Spurious?

    Science.gov (United States)

    Stift, Martin J.; Leone, Francesco

    2017-01-01

    Numerical models of atomic diffusion in magnetic atmospheres of ApBp stars predict abundance structures that differ from the empirical maps derived with (Zeeman) Doppler mapping (ZDM). An in-depth analysis of this apparent disagreement investigates the detectability by means of ZDM of a variety of abundance structures, including (warped) rings predicted by theory, but also complex spot-like structures. Even when spectra of high signal-to-noise ratio are available, it can prove difficult or altogether impossible to correctly recover shapes, positions, and abundances of a mere handful of spots, notwithstanding the use of all four Stokes parameters and an exactly known field geometry; the recovery of (warped) rings can be equally challenging. Inversions of complex abundance maps that are based on just one or two spectral lines usually permit multiple solutions. It turns out that it can by no means be guaranteed that any of the regularization functions in general use for ZDM (maximum entropy or Tikhonov) will lead to a true abundance map instead of some spurious one. Attention is drawn to the need for a study that would elucidate the relation between the stratified, field-dependent abundance structures predicted by diffusion theory on the one hand, and empirical maps obtained by means of “canonical” ZDM, i.e., with mean atmospheres and unstratified abundances, on the other hand. Finally, we point out difficulties arising from the three-dimensional nature of the atomic diffusion process in magnetic ApBp star atmospheres.

  18. Intrahepatic portosystemic venous shunts: diagnosis by Doppler ultrasound; Cortocircuitos venosos portosistemicos intrahepaticos: diagnostico mediante ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Garofano, M. P.; Medina, A.; Lopez, G.; Garrido, C. [Hospital Universitario Virgen de las Nieves. Granada (Spain)

    2001-07-01

    Intrahepatic portosystemic venous shunts are venous vascular lesions that allow intrahepatic portal vessels to communicate with hepatic veins. They may present in patients with portal hypertension or b discovered incidentally; it is considered that the latter may be congenital or acquired. A noninvasive methods. Doppler ultrasound aids in the diagnosis of these anomalous communications by providing images of the vessels and the direction, velocity and volume of the blood flow through the shunt. We present four cases of intrahepatic portosystemic venous shunt. (Author) 8 refs.

  19. The ELDORA/ASTRAIA Airborne Doppler Weather Radar: High-Resolution Observations from TOGA COARE.

    Science.gov (United States)

    Hildebrand, Peter H.; Lee, Wen-Chau; Walther, Craig A.; Frush, Charles; Randall, Mitchell; Loew, Eric; Neitzel, Richard; Parsons, Richard; Testud, Jacques; Baudin, François; Lecornec, Alain

    1996-02-01

    The ELDORA/ASTRAIA (Electra Doppler Radar/Analyese Stereoscopic par Impulsions Aeroporte) airborne Doppler weather radar was recently placed in service by the National Center for Atmospheric Research and the Centre d'étude des Environnements Terrestre et Planetaires in France. After a multiyear development effort, the radar saw its first field tests in the TOGA COARE (Tropical Oceans-Global Atmosphere Coupled Ocean-Atmosphere Response Experiment) field program during January and February 1993. The ELDORA/ASTRAIA radar (herein referred to as ELDORA) is designed to provide high-resolution measurements of the air motion and rainfall characteristics of very large storms, storms that are frequently too large or too remote to be adequately observed by ground-based radars. This paper discusses the measurement requirements and the design goals of the radar and concludes with an evaluation of the performance of the system using data from TOGA COARE.The performance evaluation includes data from two cases. First, observations of a mesoscale convective system on 9 February 1993 are used to compare the data quality of the ELDORA radar with the National Oceanic and Atmospheric Administration P-3 airborne Doppler radars. The large-scale storm structure and airflow from ELDORA are seen to compare quite well with analyses using data from the P-3 radars. The major differences observed between the ELDORA and P-3 radar analyses were due to the higher resolution of the ELDORA data and due to the different domains observed by the individual radars, a result of the selection of flight track past the storm for each aircraft. In a second example, the high-resolution capabilities of ELDORA are evaluated using observations of a shear-parallel mesoscale convective system (MCS) that occurred on 18 February 1993. This MCS line was characterized by shear-parallel clusters of small convective cells, clusters that were moving quickly with the low-level winds. High-resolution analysis of these

  20. Doppler Monitoring of the WASP-47 Multiplanet System

    CERN Document Server

    Dai, Fei; Arriagada, Pamela; Butler, R Paul; Crane, Jeffrey D; Johnson, John Asher; Shectman, Stephen A; Teske, Johanna K; Thompson, Ian B; Vanderburg, Andrew; Wittenmyer, Robert A

    2015-01-01

    We present precise Doppler observations of WASP-47, a transiting planetary system featuring a hot Jupiter with both inner and outer planetary companions. This system has an unusual architecture and also provides a rare opportunity to measure planet masses in two different ways: the Doppler method, and the analysis of transit-timing variations (TTV). Based on the new Doppler data, obtained with the Planet Finder Spectrograph on the Magellan/Clay 6.5m telescope, the mass of the hot Jupiter is $370 \\pm 29~M_{\\oplus}$. This is consistent with the previous Doppler determination as well as the TTV determination. For the inner planet WASP-47e, the Doppler data lead to a mass of $12.2\\pm 3.7~ M_{\\oplus}$, in agreement with the TTV-based upper limit of $<$22~$M_{\\oplus}$ ($95\\%$ confidence). For the outer planet WASP-47d, the Doppler mass constraint of $10.4\\pm 8.4~M_{\\oplus}$ is consistent with the TTV-based measurement of $15.2^{+6.7}_{-7.6}~ M_{\\oplus}$.

  1. Analysis of Radar Doppler Signature from Human Data

    Directory of Open Access Journals (Sweden)

    M. ANDRIĆ

    2014-04-01

    Full Text Available This paper presents the results of time (autocorrelation and time-frequency (spectrogram analyses of radar signals returned from the moving human targets. When a radar signal falls on the human target which is moving toward or away from the radar, the signals reflected from different parts of his body produce a Doppler shift that is proportional to the velocity of those parts. Moving parts of the body causes the characteristic Doppler signature. The main contribution comes from the torso which causes the central Doppler frequency of target. The motion of arms and legs induces modulation on the returned radar signal and generates sidebands around the central Doppler frequency, referred to as micro-Doppler signatures. Through analyses on experimental data it was demonstrated that the human motion signature extraction is better using spectrogram. While the central Doppler frequency can be determined using the autocorrelation and the spectrogram, the extraction of the fundamental cadence frequency using the autocorrelation is unreliable when the target is in the clutter presence. It was shown that the fundamental cadence frequency increases with increasing dynamic movement of people and simultaneously the possibility of its extraction is proportional to the degree of synchronization movements of persons in the group.

  2. Wind Retrieval Algorithms for the IWRAP and HIWRAP Airborne Doppler Radars with Applications to Hurricanes

    Science.gov (United States)

    Guimond, Stephen Richard; Tian, Lin; Heymsfield, Gerald M.; Frasier, Stephen J.

    2013-01-01

    Algorithms for the retrieval of atmospheric winds in precipitating systems from downward-pointing, conically-scanning airborne Doppler radars are presented. The focus in the paper is on two radars: the Imaging Wind and Rain Airborne Profiler(IWRAP) and the High-altitude IWRAP (HIWRAP). The IWRAP is a dual-frequency (Cand Ku band), multi-beam (incidence angles of 30 50) system that flies on the NOAAWP-3D aircraft at altitudes of 2-4 km. The HIWRAP is a dual-frequency (Ku and Kaband), dual-beam (incidence angles of 30 and 40) system that flies on the NASA Global Hawk aircraft at altitudes of 18-20 km. Retrievals of the three Cartesian wind components over the entire radar sampling volume are described, which can be determined using either a traditional least squares or variational solution procedure. The random errors in the retrievals are evaluated using both an error propagation analysis and a numerical simulation of a hurricane. These analyses show that the vertical and along-track wind errors have strong across-track dependence with values of 0.25 m s-1 at nadir to 2.0 m s-1 and 1.0 m s-1 at the swath edges, respectively. The across-track wind errors also have across-track structure and are on average, 3.0 3.5 m s-1 or 10 of the hurricane wind speed. For typical rotated figure four flight patterns through hurricanes, the zonal and meridional wind speed errors are 2 3 m s-1.Examples of measured data retrievals from IWRAP during an eyewall replacement cycle in Hurricane Isabel (2003) and from HIWRAP during the development of Tropical Storm Matthew (2010) are shown.

  3. Calculation of the Doppler broadening function using Fourier analysis;Calculo da funcao de alargamento Doppler utilizando analise de Fourier

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da Cruz

    2010-07-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function {psi}(x,{zeta}) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for {psi}(x,{zeta}), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  4. Assessing the performance of vessel wall tracking algorithms: the importance of the test phantom

    Science.gov (United States)

    Ramnarine, K. V.; Kanber, B.; Panerai, R. B.

    2004-01-01

    There is widespread clinical interest in assessing the mechanical properties of tissues and vessel walls. This study investigated the importance of the test phantom in providing a realistic assessment of clinical wall tracking performance for a variety of ultrasound modalities. B-mode, colour Doppler and Tissue Doppler Imaging (TDI) cineloop images were acquired using a Philips HDI5000 scanner and L12-5 probe. In-vivo longitudinal sections of 30 common carotid arteries and in-vitro images of pulsatile flow of a blood mimicking fluid through walled and wall-less tissue and vessel mimicking flow phantoms were analysed. Vessel wall tracking performance was assessed for our new probabilistic B-mode algorithm (PROBAL), and 3 different techniques implemented by Philips Medical Systems, based on B-mode edge detection (LDOT), colour Doppler (CVIQ) and TDI (TDIAWM). Precision (standard deviation/mean) of the peak systole dilations for respective PROBAL, LDOT, CVIQ and TDIAWM techniques were: 15.4 +/- 8.4%, 23 +/- 12.7%, 10 +/- 10% and 10.3 +/- 8.1% for the common carotid arteries; 6.4%, 22%, 11.6% and 34.5% for the wall-less flow phantom, 5.3%, 9.8%, 23.4% and 2.7% for the C-flex walled phantom and 3.9%, 2.6%, 1% and 3.2% for the latex walled phantom. The test phantom design and construction had a significant effect on the measurement of wall tracking performance.

  5. Micromotion feature extraction of radar target using tracking pulses with adaptive pulse repetition frequency adjustment

    Science.gov (United States)

    Chen, Yijun; Zhang, Qun; Ma, Changzheng; Luo, Ying; Yeo, Tat Soon

    2014-01-01

    In multifunction phased array radar systems, different activities (e.g., tracking, searching, imaging, feature extraction, recognition, etc.) would need to be performed simultaneously. To relieve the conflict of the radar resource distribution, a micromotion feature extraction method using tracking pulses with adaptive pulse repetition frequencies (PRFs) is proposed in this paper. In this method, the idea of a varying PRF is utilized to solve the frequency-domain aliasing problem of the micro-Doppler signal. With appropriate atom set construction, the micromotion feature can be extracted and the image of the target can be obtained based on the Orthogonal Matching Pursuit algorithm. In our algorithm, the micromotion feature of a radar target is extracted from the tracking pulses and the quality of the constructed image is fed back into the radar system to adaptively adjust the PRF of the tracking pulses. Finally, simulation results illustrate the effectiveness of the proposed method.

  6. Comparison of Ultrasound Corticomedullary Strain with Doppler Parameters in Assessment of Renal Allograft Interstitial Fibrosis/Tubular Atrophy.

    Science.gov (United States)

    Gao, Jing; Rubin, Jonathan M; Weitzel, William; Lee, Jun; Dadhania, Darshana; Kapur, Sandip; Min, Robert

    2015-10-01

    To compare the capability of ultrasound strain and Doppler parameters in the assessment of renal allograft interstitial fibrosis/tubular atrophy (IF/TA), we prospectively measured ultrasound corticomedullary strain (strain) and intra-renal artery Doppler end-diastolic velocity (EDV), peak systolic velocity (PSV) and resistive index (RI) in 45 renal transplant recipients before their kidney biopsies. We used 2-D speckle tracking to estimate strain, the deformation ratio of renal cortex to medulla produced by external compression using the ultrasound transducer. We also measured Doppler EDV, PSV and RI at the renal allograft inter-lobar artery. Using the Banff scoring system for renal allograft IF/TA, 45 patients were divided into the following groups: group 1 with ≤5% (n = 12) cortical IF/TA; group 2 with 6%-25% (n = 12); group 3 with 26%-50% (n = 11); and group 4 with >50% (n = 10). We performed receiver operating characteristic curve analysis to test the accuracy of these ultrasound parameters and duration of transplantation in determining >26% cortical IF/TA. In our results, strain was statistically significant in all paired groups (all p 26%, including 26%-50% and >50%) and low-grade (≤25%, including 0.05). The areas under the receiver operating characteristic curve for strain, EDV, PSV, RI and duration of transplantation in determining >26% cortical IF/TA were 0.99, 0.94, 0.88, 0.52 and 0.92, respectively. Our results suggest that corticomedullary strain seems to be superior to Doppler parameters and duration of transplantation in assessment of renal allograft cortical IF/TA.

  7. Longitudinal study of aortic isthmus Doppler in appropriately grown and small-for-gestational-age fetuses with normal and abnormal umbilical artery Doppler.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-04-01

    To establish reference ranges using longitudinal data for aortic isthmus (AoI) Doppler indices in appropriate-for-gestational-age (AGA) fetuses and to document the longitudinal trends in a cohort of small-for-gestational-age (SGA) fetuses with normal umbilical artery Doppler and in fetuses with intrauterine growth restriction (IUGR) and abnormal umbilical artery Doppler.

  8. Luge Track Safety

    CERN Document Server

    Hubbard, Mont

    2012-01-01

    Simple geometric models of ice surface shape and equations of motion of objects on these surfaces can be used to explain ejection of sliders from ice tracks. Simulations using these can be used to explain why certain design features can be viewed as proximate causes of ejection from the track and hence design flaws. This paper studies the interaction of a particle model for the luge sled (or its right runner) with the ice fillet commonly connecting inside vertical walls and the flat track bottom. A numerical example analyzes the 2010 luge accident at the Vancouver Olympics. It shows that this runner-fillet interaction, and specifically the fillet's positive curvature up the inside wall, can cause a vertical velocity more than sufficient to clear the outside exit wall. In addition its negative curvature along the track, together with large vertical velocity, explains loss of fillet or wall contact and slider ejection. This exposes the fillet along inside walls as a track design flaw. A more transparent design ...

  9. Clean tracks for ATLAS

    CERN Multimedia

    2006-01-01

    First cosmic ray tracks in the integrated ATLAS barrel SCT and TRT tracking detectors. A snap-shot of a cosmic ray event seen in the different layers of both the SCT and TRT detectors. The ATLAS Inner Detector Integration Team celebrated a major success recently, when clean tracks of cosmic rays were detected in the completed semiconductor tracker (SCT) and transition radiation tracker (TRT) barrels. These tracking tests come just months after the successful insertion of the SCT into the TRT (See Bulletin 09/2006). The cosmic ray test is important for the experiment because, after 15 years of hard work, it is the last test performed on the fully assembled barrel before lowering it into the ATLAS cavern. The two trackers work together to provide millions of channels so that particles' tracks can be identified and measured with great accuracy. According to the team, the preliminary results were very encouraging. After first checks of noise levels in the final detectors, a critical goal was to study their re...

  10. ADEPT - Abnormal Doppler Enteral Prescription Trial

    Directory of Open Access Journals (Sweden)

    McCormick Kenny

    2009-10-01

    Full Text Available Abstract Background Pregnancies complicated by abnormal umbilical artery Doppler blood flow patterns often result in the baby being born both preterm and growth-restricted. These babies are at high risk of milk intolerance and necrotising enterocolitis, as well as post-natal growth failure, and there is no clinical consensus about how best to feed them. Policies of both early milk feeding and late milk feeding are widely used. This randomised controlled trial aims to determine whether a policy of early initiation of milk feeds is beneficial compared with late initiation. Optimising neonatal feeding for this group of babies may have long-term health implications and if either of these policies is shown to be beneficial it can be immediately adopted into clinical practice. Methods and Design Babies with gestational age below 35 weeks, and with birth weight below 10th centile for gestational age, will be randomly allocated to an "early" or "late" enteral feeding regimen, commencing milk feeds on day 2 and day 6 after birth, respectively. Feeds will be gradually increased over 9-13 days (depending on gestational age using a schedule derived from those used in hospitals in the Eastern and South Western Regions of England, based on surveys of feeding practice. Primary outcome measures are time to establish full enteral feeding and necrotising enterocolitis; secondary outcomes include sepsis and growth. The target sample size is 400 babies. This sample size is large enough to detect a clinically meaningful difference of 3 days in time to establish full enteral feeds between the two feeding policies, with 90% power and a 5% 2-sided significance level. Initial recruitment period was 24 months, subsequently extended to 38 months. Discussion There is limited evidence from randomised controlled trials on which to base decisions regarding feeding policy in high risk preterm infants. This multicentre trial will help to guide clinical practice and may also

  11. Doppler ultrasound and giant cell arteritis

    Directory of Open Access Journals (Sweden)

    Ana Marina Suelves

    2010-11-01

    Full Text Available Ana Marina Suelves1, Enrique España-Gregori1,2, Jose Tembl3, Stephanie Rohrweck1, Jose Maria Millán4, Manuel Díaz-Llopis1,4,51Service of Ophthalmology, La Fe University Hospital, Valencia, Spain; 2Department of Optics, University of Valencia, Valencia, Spain; 3Service of Neurology, La Fe University Hospital, Valencia, Spain; 4CIBERER, Ciber de Enfermedades Raras, Valencia, Spain; 5Faculty of Medicine, University of Valencia, Valencia, SpainObjective: To evaluate the utility of ultrasound in aiding the diagnosis of giant cell arteritis (GCA, in monitoring the response to corticotherapy, and in detecting early relapses.Methods: A pilot study, prospective, included 10 patients with suspected GCA. All patients underwent ultrasound examination of both temporal arteries before temporal artery biopsy (TAB, 3 weeks after starting treatment, and 3 months after diagnosis. For this study, the histological findings alone were used to define if patients were suffering from GCA. The findings on ultrasound were compared with the results of biopsy. The best place to perform TAB was observed by ultrasound.Results: All patients with positive biopsy were detected with ultrasound. No false positives were observed on ultrasound. The results presented give a sensibility, specificity, and positive predictive value of 100% for the use of ultrasound in the diagnosis of GCA. Two relapses were detected early by ultrasound during the follow-up.Conclusions: This pilot study suggests that eco-doppler may be a useful tool in diagnosis and clinic follow-up in patients with suspected GCA.Keywords: giant cell arteritis, ultrasound, temporal artery biopsy, optic nerve

  12. Single Mode, Extreme Precision Doppler Spectrographs

    Science.gov (United States)

    Schwab, Christian; Leon-Saval, Sergio G.; Betters, Christopher H.; Bland-Hawthorn, Joss; Mahadevan, Suvrath

    2014-04-01

    The `holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a limiting factor in current multimode fiber fed instruments (Baudrand & Walker 2001), can be eliminated by proper design, and the diffraction limited input to the spectrograph allows for very compact instrument designs, which provide excellent optomechanical stability. A SMF is the ideal interface for new, very precise wavelength calibrators, like laser frequency combs (Steinmetz et al. 2008, Osterman et al. 2012), or SMF based Fabry-Perot Etalons (Halverson et al. 2013). At near infrared wavelengths, these technologies are ready to be implemented in on-sky instruments, or already in use. We discuss a novel concept for such a spectrograph.

  13. Interpreting laser Doppler recordings from free flaps.

    Science.gov (United States)

    Svensson, H; Holmberg, J; Svedman, P

    1993-01-01

    Although the transfer of free flaps is nowadays accomplished with an increasing degree of safety, thrombosis of the microvascular anastomoses is still a problem. In order to avoid delay in re-operating, various methods for objective blood flow monitoring have been tried, among them Laser Doppler Flowmetry (LDF). When one reviews the literature, it is apparent that opinions differ about whether or not LDF is a reliable technique for this purpose. To focus on the need to interpret continuous recordings, this paper reports our findings in six latissimus dorsi free flaps chosen from our series of LDF monitoring procedures. One uneventful flap, no. 1, had an immediate postoperative LDF value of 4.5 perfusion units (PU). LDF values improved during the recovery period and the graphic recording showed fluctuations due to normal physiological variations of the blood flow in the flap. Another uneventful flap, no. 4, showed the same pattern, though at an appreciably lower level, 2 PU, on average. Flap no. 2 had an acceptably high value of 3.5 PU despite suffering a venous thrombosis. However, the LDF recording showed no fluctuations and the value declined gradually. Another flap, no. 3, showed fluctuations and blood flow was normal although the value decreased to 2.5 PU. In flap no. 5, any value between 2 and 3.5 PU could be obtained merely by adjusting the position of the probe in the holder. In no. 6, the LDF value suddenly dropped, accompanied by a decrease in the total amount of backscattered light, indicating venous obstruction which was confirmed at re-operation.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    Energy Technology Data Exchange (ETDEWEB)

    Showman, Adam P.; Lewis, Nikole K. [Department of Planetary Sciences and Lunar and Planetary Laboratory, The University of Arizona, 1629 University Boulevard, Tucson, AZ 85721 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Shabram, Megan, E-mail: showman@lpl.arizona.edu [Department of Astronomy, University of Florida, 211 Bryant Space Science Center, Gainesville, FL 32611-2055 (United States)

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation-and Doppler signature-of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the {approx}2 km s{sup -1} blueshift inferred on HD 209458b may require drag time constants as short as 10{sup 4}-10{sup 6} s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  15. Deep 6-DOF Tracking.

    Science.gov (United States)

    Garon, Mathieu; Lalonde, Jean-Francois

    2017-08-10

    We present a temporal 6-DOF tracking method which leverages deep learning to achieve state-of-the-art performance on challenging datasets of real world capture. Our method is both more accurate and more robust to occlusions than the existing best performing approaches while maintaining real-time performance. To assess its efficacy, we evaluate our approach on several challenging RGBD sequences of real objects in a variety of conditions. Notably, we systematically evaluate robustness to occlusions through a series of sequences where the object to be tracked is increasingly occluded. Finally, our approach is purely data-driven and does not require any hand-designed features: robust tracking is automatically learned from data.

  16. AIRSHIP ATTITUDE TRACKING SYSTEM

    Institute of Scientific and Technical Information of China (English)

    WANG Xiao-liang; SHAN Xue-xiong

    2006-01-01

    The attitude tracking control problem for an airship with parameter uncertainties and external disturbances was considered in this paper. The mathematical model of the airship attitude is a multi-input/multi-output uncertain nonlinear system. Based on the characteristics of this system, a design method of robust output tracking controllers was adopted based on the upper-bounds of the uncertainties. Using the input/output feedback linearization approach and Liapunov method, a control law was designed, which guarantees that the system output exponentially tracks the given desired output. The controller is easy to compute and complement. Simulation results show that, in the closed-loop system, precise attitude control is accomplished in spite of the uncertainties and external disturbances in the system.

  17. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  18. Negotiating Family Tracking

    DEFF Research Database (Denmark)

    Sonne Damkjær, Maja; Albrechtslund, Anders; Bøge, Ask Risom

    This presentation explores the question: What motivates the use of tracking technologies in families, and how does the use transform the relations between parent and child? The purpose is to investigate why tracking technologies are used in families and how these technologies potentially change...... the relation between parents and children. The use of tracking technologies in families implicate negotiations about the boundaries of trust and intimacy in parent-child relations which can lead to strategies of resistance or modification (Fotel and Thomsen, 2004; Rooney, 2010; Steeves and Jones, 2010......). In the presentation, we report from a qualitative study that focuses on intergenerational relations. The study draws on empirical data from workshops with Danish families as well as individual and group interviews. We aim to gain insights about the sharing habits and negotiations in intimate family relations...

  19. Tracking of deformable objects

    Science.gov (United States)

    Aswani, Parimal; Wong, K. K.; Chong, Man N.

    2000-12-01

    Tracking of moving-objects in image sequences is needed for several video processing applications such as content-based coding, object oriented compression, object recognition and more recently for video object plane extraction in MPEG-4 coding. Tracking is a natural follow-up of motion-based segmentation. It is a fast and efficient method to achieve coherent motion segments along the temporal axis. Segmenting out moving objects for each and every frame in a video sequence is a computationally expensive approach. Thus, for better performance, semi-automatic segmentation is an acceptable compromise as automatic segmentation approaches rely heavily on prior assumptions. In semi-automatic segmentation approaches, motion-segmentation is performed only on the initial frame and the moving object is tracked in subsequent frames using tracking algorithms. In this paper, a new model for object tracking is proposed, where the image features -- edges, intensity pattern, object motion and initial keyed-in contour (by the user) form the prior and likelihood model of a Markov Random Field (MRF) model. Iterated Conditional Mode (ICM) is used for the minimization of the global energy for the MRF model. The motion segment for each frame is initialized using the segment information from the previous frame. For the initial frame, the motion segment is obtained by manually keying in the object contour. The motion-segments obtained using the proposed model are coherent and accurate. Experimental results on tracking using the proposed algorithm for different sequences -- Bream, Alexis and Claire are presented in this paper. The results obtained are accurate and can be used for a variety of applications including MPEG-4 Video Object Plane (VOP) extraction.

  20. Tracking Your Development

    CERN Document Server

    Hennum, Kelly M

    2011-01-01

    This book provides you with the means to set development goals and to track your progress on achieving them. It can help you efficiently gather and make sense of information about your progress and avoid common pitfalls that can block your development. Tracking your development can be captures in a few steps: articulating your goal, creating an action plan, gathering information about your behavior, indentifying barriers and support, and revising your action plan. Taking these steps will greatly increase the likelihood of achieving your goals.

  1. The value of micro-Doppler in stereotactic brain biopsy.

    Science.gov (United States)

    Hertel, F; Feiden, W; Bettag, M

    2005-06-01

    The aim of this study was to analyse the value of intraoperative micro-Doppler in stereotactic brain biopsy (SBB). So far, only a few studies have reported about the usefulness of micro-Doppler in stereotactic brain biopsy. Between 1998 and 2003, 155 SBBs were performed in 153 patients with micro-Doppler (81 males, 72 females, mean age: 59 years). All operations were performed using a ZD-frame and a multiplanar computer tomography-guided trajectory planning system (Leibinger SPP). A 16 MHz micro-Doppler probe (diameter 1 mm, DWL) was used in all cases to explore the area of biopsy before the tissue probes were taken. Serial biopsies (mean, 6 samples) were taken with the Sedan side-cutting cannula (n = 145) or the small forceps (n = 10). We evaluated the number of intraoperative detectable vessel signals by micro-Doppler, intraoperative bleedings as well as bleedings detected by postoperative CT (which was performed in all cases). We compared our results according to bleeding-related complications with the data of stereotactic biopsy series from the recent literature. A conclusive histopathological diagnosis was achieved in 150/153 patients (98 %). A re-biopsy had to be undertaken in 2 cases. In 98 biopsies (63 %), no vessel could be detected with the micro-Doppler. In the remainder, a signal of arterial vessels was detected in 22 (14 %) and a signal of venous vessels in 35 cases (23 %). Detection of a vessel in the micro-Doppler led to a change of the biopsy site in each case within the same trajectory. Biopsy-related bleedings were detected in 4 cases (2.6 %). Among these, the only bleeding which occurred without any signs of vessels in the micro-Doppler happened in a case of a melanoma. The overall biopsy-related permanent morbidity was 0.6 % (n = 1). The biopsy-related mortality was 0. Despite the overall high security of SBB, the use of intraoperative micro-Doppler may lead to an additional reduction of the risk for a biopsy-related bleeding without enormous

  2. Track Reconstruction Performance in CMS

    CERN Document Server

    Azzurri, Paolo

    2008-01-01

    The expected performance of track reconstruction with LHC events using the CMS silicon tracker is presented. Track finding and fitting is accomplished with Kalman Filter techniques that achieve efficiencies above 99\\% on single muons with $p_T >$1~GeV/c. Difficulties arise in the context of standard LHC events with a high density of charged particles, where the rate of fake combinatorial tracks is very large for low $p_T$ tracks, and nuclear interactions in the tracker material reduce the tracking efficiency for charged hadrons. Recent improvements with the CMS track reconstruction now allow to efficiently reconstruct charged tracks with $p_T$ down to few hundred MeV/c and as few as three crossed layers, with a very small fake fraction, by making use of an optimal rejection of fake tracks in conjunction with an iterative tracking procedure.

  3. Laser Doppler perfusion monitoring and imaging of blood microcirculation

    Science.gov (United States)

    Nilsson, Gert E.; Wardell, Karin

    1994-07-01

    Laser Doppler perfusion monitoring is a method of assessing tissue perfusion based on measurements performed using Doppler broadening of monochromatic light scattered in moving blood cells. Ever since laser Doppler perfusion monitors became available about 15 years ago they have been used in numerous applications in both clinical and laboratory settings. The high spatial resolution has in practice manifested itself as one of the main limitations of the method. The reason for this is the difficulty in attaining reproducible values at successive measurement sites because most skin tissue possesses a substantial variation in blood flow even at adjacent measurement sites. In order to overcome this difficulty the laser Doppler perfusion imager was developed. In this camera-like device, the laser beam successively scans the tissue and the Doppler components of the backscattered light are detected by a remote photodiode. After a scanning procedure is complete, a color-coded perfusion map showing the spatial variation of skin blood flow is displayed on a monitor. The operating principle and early applications of this emerging technology are addressed in further detail.

  4. Short period ionospheric perturbations from continuous Doppler sounding

    Science.gov (United States)

    Fiser, Jiri; Chum, Jaroslav; Lastovicka, Jan; Buresova, Dalia

    2017-04-01

    Results of recent observations of ionospheric perturbations on short time scales obtained by international network (Czech Republic, Argentina, Taiwan and South Africa) of multipoint continuous Doppler sounders with time resolution about 10 s are presented. Examples of observation and analysis of propagation of gravity waves (GWs), equatorial spread F (ESF), infrasound from earthquake and large convective systems, as well as ionospheric perturbations caused by solar flares will be shown. It is documented that roughly poleward propagation of GWs dominates in the local summer, whereas mainly equatorward propagation is observed in the local winter. The analysis of occurrences and zonal drifts of ESF based on Doppler sounding are consistent with optical and satellite measurements. The observations of co-seismic perturbations by Doppler sounders in the vicinity of ionosondes and seismic sensors proved that the co-seismic perturbations are caused by approximately vertically propagating infrasound waves triggered by vertical motion of the ground surface. Numerical simulations and Doppler measurements confirmed that in the vicinity (up to about 1000 km) from epicenters of strong earthquake, the infrasound propagates in nonlinear regime in the upper atmosphere, which results in the formation of N-shaped pulse. Solar flares are observed both as sudden frequency deviations and amplitude attenuations of Doppler signal.

  5. Detector resolution in positron annihilation Doppler broadening experiments

    Science.gov (United States)

    Heikinheimo, J.; Ala-Heikkilä, J.; Tuomisto, F.

    2017-09-01

    Positron annihilation Doppler broadening spectroscopy characterizes lattice point defects and is sensitive to very small vacancy densities. High-purity germanium detectors are generally used for recording the Doppler broadening spectrum because they provide good energy resolution and stability. However, the energy resolution of a germanium detector is somewhat dependent on the photon absorption geometry in the detector crystal. This change in the energy resolution changes also the Doppler broadening parameters. To observe the dependency of the resolution function and the Doppler broadening parameters, we performed experiments on Si samples in standard sandwich configuration with a Na-22 source. We changed the radiation geometry of the incident gamma photons via altering the distance of the sample-source package from the detector and by adding steel between the source and the detector. We observed the change of the absorption geometry in the germanium detector crystal by doing Monte Carlo simulations. The aim of this study is to help understand and decide what is the best way to compare the Doppler broadening parameters obtained with different measurement setups and even with the same setup when the geometry in the measurements has changed.

  6. Color Doppler US in the acute scrotal disease

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Yoo Mi; Yang, Dal Mo; Kang, Sook Wook; Kim, Hyung Sik; Lee, Young Seok; Kim, Hyeon Hoe [Chung Ang Gil Hospital, Incheon (Korea, Republic of)

    1993-12-15

    To evaluate the utility of Color doppler US in the patients with acute scrotal pain, we retrospectively analyzed 37 patients referred for Color Doppler US of the scrotum. The diagnosis was confirmed by means of appropriate response to antibiotic treatment (31 cases) or surgery (6 cases). Thirty one of 37 patients were diagnosed as inflammatory disease (24 cases of epididymitis, 7 cases of epididymo-orchitis). Twenty three of 24cases of epididymitis had increased epididymal flow, while 6 of 7 cases of epididymo-orchitis had increased epididymal and testicular flow. Five patients were confirmed as testicular torsion, and in all cases nointratesticular blood flow was identified on the symptomatic side. In one case of torsion of appendix testis, epididymis was enlarged and there were increased signals suggesting epididymitis on Color Doppler US, but was confirmed by surgery as torsion of appendix testis. Therefore, the differentiation between torsion and inflammatory disease was possible by using Color Doppler US of the scrotum in 34 of 37 cases in our study. On the basis of our results, we may conclude that Color Doppler US can simultaneously display blood flow and detailed anatomic images, and function as an effective means of evaluating patients with acute scrotal disease

  7. Influence of speckle effect on doppler velocity measurement

    Science.gov (United States)

    Zheng, Zheng; Changming, Zhao; Haiyang, Zhang; Suhui, Yang; Dehua, Zhang; Xingyuan, Zheng; Hongzhi, Yang

    2016-06-01

    In a coherent Lidar system, velocity measurement of a target is achieved by measuring Doppler frequency shift between the echo and local oscillator (LO) signals. The measurement accuracy is proportional to the spectrum width of Doppler signal. Actually, the speckle effect caused by the scattering of laser from a target will broaden the Doppler signal's spectrum and bring uncertainty to the velocity measurement. In this paper, a theoretical model is proposed to predict the broadening of Doppler spectrum with respect to different target's surface and motion parameters. The velocity measurement uncertainty caused by the broadening of spectrum is analyzed. Based on the analysis, we design a coherent Lidar system to measure the velocity of the targets with different surface roughness and transverse velocities. The experimental results are in good agreement with theoretical analysis. It is found that the target's surface roughness and transverse velocity can significantly affect the spectrum width of Doppler signal. With the increase of surface roughness and transverse velocity, the measurement accuracy becomes worse. However, the influence of surface roughness becomes weaker when the spot size of laser beam on the target is smaller.

  8. Renal Power Doppler Ultrasonographic Evaluation of Children With Acute Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Ali Pahlusi

    2011-10-01

    Full Text Available Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.82.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  9. Selection functions in doppler planet searches

    Science.gov (United States)

    O'Toole, S. J.; Tinney, C. G.; Jones, H. R. A.; Butler, R. P.; Marcy, G. W.; Carter, B.; Bailey, J.

    2009-01-01

    We present a preliminary analysis of the sensitivity of Anglo-Australian Planet Search data to the orbital parameters of extrasolar planets. To do so, we have developed new tools for the automatic analysis of large-scale simulations of Doppler velocity planet search data. One of these tools is the two-dimensional Keplerian Lomb-Scargle (LS) periodogram that enables the straightforward detection of exoplanets with high eccentricities (something the standard LS periodogram routinely fails to do). We used this technique to redetermine the orbital parameters of HD20782b, with one of the highest known exoplanet eccentricities (e = 0.97 +/- 0.01). We also derive a set of detection criteria that do not depend on the distribution functions of fitted Keplerian orbital parameters (which we show are non-Gaussian with pronounced, extended wings). Using these tools, we examine the selection functions in orbital period, eccentricity and planet mass of Anglo-Australian Planet Search data for three planets with large-scale Monte Carlo like simulations. We find that the detectability of exoplanets declines at high eccentricities. However, we also find that exoplanet detectability is a strong function of epoch-to-epoch data quality, number of observations and period sampling. This strongly suggests that simple parametrizations of the detectability of exoplanets based on `whole-of-survey' metrics may not be accurate. We have derived empirical relationships between the uncertainty estimates for orbital parameters that are derived from least-squares Keplerian fits to our simulations and the true 99 per cent limits for the errors in those parameters, which are larger than equivalent Gaussian limits by the factors of 5-10. We quantify the rate at which false positives are made by our detection criteria, and find that they do not significantly affect our final conclusions. And finally, we find that there is a bias against measuring near-zero eccentricities, which becomes more significant

  10. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl;

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...... guidelines and recommendations are based on personal experience since no evidence in literature exists. The basic technical background of Doppler ultrasound and typical artefacts will be discussed, in order to understand and interpret the Doppler result. Recommendations for the Doppler settings are given...... in relevant sections. Ultrasound guided treatments where the Doppler result is used as a guide are mentioned and discussed....

  11. Tracking Speech Sound Acquisition

    Science.gov (United States)

    Powell, Thomas W.

    2011-01-01

    This article describes a procedure to aid in the clinical appraisal of child speech. The approach, based on the work by Dinnsen, Chin, Elbert, and Powell (1990; Some constraints on functionally disordered phonologies: Phonetic inventories and phonotactics. "Journal of Speech and Hearing Research", 33, 28-37), uses a railway idiom to track gains in…

  12. Tracking Politics with POWER

    Science.gov (United States)

    Moreira, Silvio; Batista, David S.; Carvalho, Paula; Couto, Francisco M.; Silva, Mario J.

    2013-01-01

    Purpose: POWER is an ontology of political processes and entities. It is designed for tracking politicians, political organizations and elections, both in mainstream and social media. The aim of this paper is to propose a data model to describe political agents and their relations over time. Design/methodology/approach: The authors propose a data…

  13. Fast Passenger Tracks Network

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    China’s fast passenger tracks network consists of four parts:express rail- way with speeds between 300km/h and 350 kin/h,passenger rail lines with speeds between 200 km/h and 250 km/h,intercity high-speed railways that run

  14. Pseudonoise code tracking loop

    Science.gov (United States)

    Laflame, D. T. (Inventor)

    1980-01-01

    A delay-locked loop is presented for tracking a pseudonoise (PN) reference code in an incoming communication signal. The loop is less sensitive to gain imbalances, which can otherwise introduce timing errors in the PN reference code formed by the loop.

  15. Energy Tracking Diagrams

    Science.gov (United States)

    Scherr, Rachel E.; Harrer, Benedikt W.; Close, Hunter G.; Daane, Abigail R.; DeWater, Lezlie S.; Robertson, Amy D.; Seeley, Lane; Vokos, Stamatis

    2016-01-01

    Energy is a crosscutting concept in science and features prominently in national science education documents. In the "Next Generation Science Standards," the primary conceptual learning goal is for learners to conserve energy as they "track" the transfers and transformations of energy within, into, or out of the system of…

  16. Tracking Speech Sound Acquisition

    Science.gov (United States)

    Powell, Thomas W.

    2011-01-01

    This article describes a procedure to aid in the clinical appraisal of child speech. The approach, based on the work by Dinnsen, Chin, Elbert, and Powell (1990; Some constraints on functionally disordered phonologies: Phonetic inventories and phonotactics. "Journal of Speech and Hearing Research", 33, 28-37), uses a railway idiom to track gains in…

  17. Attitude and position tracking

    CSIR Research Space (South Africa)

    Candy, LP

    2011-01-01

    Full Text Available velocity data separately in a suitable frame. In this chapter we make the case for using bivectors as the attitude tracking method of choice since several features make their performance and flexibility superior to that of DCMs, Euler angles or even rotors...

  18. Tracking Self into Place

    Science.gov (United States)

    Piersol, Laura

    2010-01-01

    In an effort to figure out what it means to educate "ecologically," I decided to track down some of the stories that I was living, telling and making as an educator. I ended up lost in the house of environmental education, stuck within the rooms of ecological science and political advocacy. Outside on the lawn sat the story of place based…

  19. Foinaven fast track flowlines

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, L.H.; Mair, J.

    1996-12-31

    The decision by British Petroleum to develop offshore fields west of the Shetlands in water depths exceeding 500 meters within three and a half years of discovery posed a unique submarine pipeline installation challenge. This paper summarizes the salient features of a fast track program to install a diverless subsea pipeline system using rigid reeled pipe technology in an offshore frontier area.

  20. Eye tracking social preferences

    NARCIS (Netherlands)

    Jiang, Ting; Potters, Jan; Funaki, Yukihiko

    We hypothesize that if people are motivated by a particular social preference, then choosing in accordance with this preference will lead to an identifiable pattern of eye movements. We track eye movements while subjects make choices in simple three-person distribution experiments. We characterize

  1. Apple Shuns Tracking Tool

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Apple Inc. is advising software de- velopers to stop using a feature in software for its iPhones and iPads .that has been linked to privacyconcerns, a move that would also take away a widely used tool for tracking users and their behavior. Developers who write programs for Apple's lOS operating system have been using a unique.

  2. Ecocardiografia modo Doppler pulsado em gatos clinicamente sadios Pulsed wave Doppler echocardiography in clinically healthy cats

    Directory of Open Access Journals (Sweden)

    R.O. Carvalho

    2006-06-01

    Full Text Available Estudou-se o fluxo sangüíneo através das quatro valvas cardíacas em 30 gatos clinicamente sadios, com idade entre um e cinco anos e peso médio de 4,08kg, por meio da ecocardiografia modo Doppler pulsado. Foram medidas a velocidade máxima e a velocidade média dos fluxos, e realizou-se uma análise qualitativa dos seus perfis. Os animais foram sedados pela combinação de quetamina (12mg/kg e acepromazina (0,04mg/kg, aplicados por via intramuscular. Observou-se correlação positiva entre os parâmetros avaliados e a freqüência cardíaca, com exceção daqueles medidos no fluxo da valva aórtica. Não se observou correlação entre velocidades máxima e média e freqüência cardíaca e entre aquelas e peso corporal, e não houve diferença entre sexos.Pulsed wave Doppler echocardiography was used to study blood flow across the cardiac valves in 30 five-year-old cats (average body weight = 4.08kg. Animals were sedated using a combination of ketamin (12mg/kg, IM and acepromazin (0.04mg/kg, IM. Peak and mean velocities were determined, and blood flow patterns were recorded at the four cardiac valves. All variables, except those characterizing aortic valve flow, were positively correlated with heart rate. Blood flow variables were not correlated, however, with body weight; and there were no differences between males and females.

  3. GPS Metric Tracking Unit

    Science.gov (United States)

    2008-01-01

    As Global Positioning Satellite (GPS) applications become more prevalent for land- and air-based vehicles, GPS applications for space vehicles will also increase. The Applied Technology Directorate of Kennedy Space Center (KSC) has developed a lightweight, low-cost GPS Metric Tracking Unit (GMTU), the first of two steps in developing a lightweight, low-cost Space-Based Tracking and Command Subsystem (STACS) designed to meet Range Safety's link margin and latency requirements for vehicle command and telemetry data. The goals of STACS are to improve Range Safety operations and expand tracking capabilities for space vehicles. STACS will track the vehicle, receive commands, and send telemetry data through the space-based asset, which will dramatically reduce dependence on ground-based assets. The other step was the Low-Cost Tracking and Data Relay Satellite System (TDRSS) Transceiver (LCT2), developed by the Wallops Flight Facility (WFF), which allows the vehicle to communicate with a geosynchronous relay satellite. Although the GMTU and LCT2 were independently implemented and tested, the design collaboration of KSC and WFF engineers allowed GMTU and LCT2 to be integrated into one enclosure, leading to the final STACS. In operation, GMTU needs only a radio frequency (RF) input from a GPS antenna and outputs position and velocity data to the vehicle through a serial or pulse code modulation (PCM) interface. GMTU includes one commercial GPS receiver board and a custom board, the Command and Telemetry Processor (CTP) developed by KSC. The CTP design is based on a field-programmable gate array (FPGA) with embedded processors to support GPS functions.

  4. Non-Gaussianity and CMB aberration and Doppler

    CERN Document Server

    Catena, Riccardo; Notari, Alessio; Renzi, Alessandro

    2013-01-01

    The peculiar motion of an observer with respect to the CMB rest frame induces a deflection in the arrival direction of the observed photons (also known as CMB aberration) and a Doppler shift in the measured photon frequencies. As a consequence, aberration and Doppler effects induce non trivial correlations between the harmonic coefficients of the observed CMB temperature maps. In this paper we investigate whether these correlations generate a bias on Non-Gaussianity estimators $f_{NL}$. We perform this analysis simulating a large number of temperature maps with Planck-like resolution (lmax $= 2000$) as different realizations of the same cosmological fiducial model (WMAP7yr). We then add to these maps aberration and Doppler effects employing a modified version of the HEALPix code. We finally evaluate a generalization of the Komatsu, Spergel and Wandelt Non-Gaussianity estimator for all the simulated maps, both when peculiar velocity effects have been considered and when these phenomena have been neglected. Usi...

  5. Doppler Spectrum from Moving Scatterers in a Random Environment

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    2009-01-01

    as well as sharply peaked distributions are considered in the theory. The Doppler spectra are in all cases sharply peaked at zero frequency due to forward scattering, but the actually measured distribution depends on the degree and type of activity in the environment, as well as the spectrum estimation......A random non-line-of-sight environment with stationary transmitter and receiver is considered. In such an environment movement of a scatterer will lead to perturbations of the otherwise static channel with a resulting Doppler spectrum. This is quite a general situation in outdoor environments...... with moving traffic or indoor situations with moving people. Here we study the latter situation in detail with experimental results from a large office environment. A general theory of Doppler spectra is developed. The impact of a scatterer depends on the angular distribution of scattered energy, and uniform...

  6. One way Doppler Extractor. Volume 2: Digital VCO technique

    Science.gov (United States)

    Nossen, E. J.; Starner, E. R.

    1974-01-01

    A feasibility analysis and trade-offs for a one-way Doppler extractor using digital VCO techniques is presented. The method of Doppler measurement involves the use of a digital phase lock loop; once this loop is locked to the incoming signal, the precise frequency and hence the Doppler component can be determined directly from the contents of the digital control register. The only serious error source is due to internally generated noise. Techniques are presented for minimizing this error source and achieving an accuracy of 0.01 Hz in a one second averaging period. A number of digitally controlled oscillators were analyzed from a performance and complexity point of view. The most promising technique uses an arithmetic synthesizer as a digital waveform generator.

  7. Micro-range micro-doppler for dismount classification

    Science.gov (United States)

    Tahmoush, Dave

    2013-05-01

    This paper presents a processing technique that can be used to detect and classify pedestrians group based on the micro- Doppler signature gathered with a millimeter wave radar. The evaluation of the number of pedestrians moving in a group can be a difficult task using a traditional micro-Doppler spectrogram because of a tendency for people to partially synchronize their steps when walking together. The new approach, based on multi-range variation as well as the micro-Doppler variations, provides promising results. The range-spectrogram processing technique was developed and tested using a database composed of hundreds of pedestrian and vehicle signatures gathered in an urban test site over a two year period in a variety of weather conditions. We associate image detections with radar detections through motion extracted from both radar and imagery. We also explain how radar and video together can produce an inexpensive alternative to 3-D imaging.

  8. Automatic human micro-Doppler signature separation by Hough transform

    Science.gov (United States)

    Zhang, Jun; Jin, Tian; Qiu, Lei; Zhou, Zhimin

    2015-12-01

    The micro-Doppler signature is one of the most prominent information for target classification and identification. As Hough transform (HT) is an efficient tool for detecting weak straight target traces in the image, an HT based algorithm is proposed for micro-Doppler signature separation of multiple persons. Few seconds data is processed at one time to ensure human motion traces approximate to straight lines in the radar slow time-range image. Taking HT to the slow time-range image, each human's motion trace can be recovered through recursively searching the peaks in HT space. Applying time-frequency transform to the range cells around each recovered line, the human micro-Doppler signature can be achieved and separated. Experimental results are given to illustrate the validity of the proposed algorithm.

  9. Holographic laser Doppler imaging of microvascular blood flow

    CERN Document Server

    Magnain, C; Boucneau, T; Simonutti, M; Ferezou, I; Rancillac, A; Vitalis, T; Sahel, J A; Paques, M; Atlan, M

    2014-01-01

    We report on local superficial blood flow monitoring in biological tissue from laser Doppler holographic imaging. In time averaging recording conditions, holography acts as a narrowband bandpass filter, which, combined with a frequency shifted reference beam, permits frequency selective imaging in the radiofrequency range. These Doppler images are acquired with an off axis Mach Zehnder interferometer. Microvascular hemodynamic components mapping is performed in the cerebral cortex of the mouse and the eye fundus of the rat with near-infrared laser light without any exogenous marker. These measures are made from a basic inverse method analysis of local first order optical fluctuation spectra at low radiofrequencies, from 0 Hz to 100 kHz. Local quadratic velocity is derived from Doppler broadenings induced by fluid flows, with elementary diffusing wave spectroscopy formalism in backscattering configuration. We demonstrate quadratic mean velocity assessment in the 0.1 to 10 millimeters per second range in vitro ...

  10. Improved technique for blood flow velocity measurement using Doppler effect

    Science.gov (United States)

    Valadares Oliveira, Eduardo J.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.

    2002-04-01

    The Doppler velocimeter developed allows to determine the angle between the ultrasonic beam and the velocity vector of the flow, and to calculate the precise blood flow in a vessel. Four piezoelectric transducers constitute the Doppler velocimeter. Three of these transducers are positioned to form an equilateral triangle (base of a pyramid). When these transducers move simultaneously, backward or forward from the initial position, the emitted ultrasonic beams focalize on a position (peak of the pyramid) closer or farther from the transducers faces, according to the depth of the vessel where we intend to measure de flow. The angle between the transducers allows adjusting the height of this pyramid and the position of the focus (where the three beams meet). A forth transducer is used to determine the diameter of the vessel and monitor the position of the Doppler velocimeter relative to the vessel. Simulation results showed that with this technique is possible to accomplish precise measurement of blood flow.

  11. Curvelet Transform-Based Denoising Method for Doppler Frequency Extraction

    Institute of Scientific and Technical Information of China (English)

    HOU Shu-juan; WU Si-liang

    2007-01-01

    A novel image denoising method based on curvelet transform is proposed in order to improve the performance of Doppler frequency extraction in low signal-noise-ratio (SNR) environment. The echo can be represented as a gray image with spectral intensity as its gray values by time-frequency transform. And the curvelet coefficients of the image are computed. Then an adaptive soft-threshold scheme based on dual-median operation is implemented in curvelet domain. After that, the image is reconstructed by inverse curvelet transform and the Doppler curve is extracted by a curve detection scheme. Experimental results show the proposed method can improve the detection of Doppler frequency in low SNR environment.

  12. Theoretical analysis and experimental verification on optical rotational Doppler effect

    CERN Document Server

    Zhou, Hailong; Dong, Jianji; Zhang, Pei; Zhang, Xinliang

    2016-01-01

    We present a theoretical model to sufficiently investigate the optical rotational Doppler effect based on modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the difference of mode index between input and output orbital angular momentum (OAM) light, and linear to the rotating speed of spinning object as well. An experiment is carried out to verify the theoretical model. We explicitly suggest that the spatial spiral phase distribution of spinning object determines the frequency content. The theoretical model makes us better understand the physical processes of rotational Doppler effect, and thus has many related application fields, such as detection of rotating bodies, imaging of surface and measurement of OAM light.

  13. Doppler-like effect and doubtful expansion of universe

    CERN Document Server

    Szaraniec, E

    2003-01-01

    The distance contraction, as observed in electrical soundings over horizontally stratified earth (static system), is identified as a counterpart of Doppler shift in dynamical systems. Identification of Doppler-like effect in a stock-still systems makes it possible to give an al-ternative answer to the question about an effective cause of the Doppler shift, which sounds: the inhomogeneities. This answer opens different static as well as kinematic possibilities, which challenge established theories of expanding universe and energizing big bang.The energy propagating in stratified universe of layers exhibits a shift which could be at-tributed not only to the expansion (Hubble's theory) but alternatively to fluctuations in material properties (inhomogeneities).

  14. It's all in the past: Deconstructing the temporal Doppler effect.

    Science.gov (United States)

    Aksentijevic, Aleksandar; Treider, John Melvin Gudnyson

    2016-10-01

    A recent study reported an asymmetry between subjective estimates of future and past distances with passive estimation and virtual movement. The temporal Doppler effect refers to the contraction of future distance judgments relative to past ones. We aimed to replicate the effect using real and imagined motion in both directions as well as different temporal perspectives. To avoid the problem of subjective anchoring, we compared real- and imagined-, ego- and time-moving conditions to a control group. Generally, Doppler-like distortion was only observed in conditions in which the distance between the participant and a frontal target increased. No effects of temporal perspective were observed. The "past-directed temporal Doppler effect" presents a challenge for the current theories of temporal cognition by demonstrating absence of psychological movement into the future. The effect could open new avenues in memory research and serve as a starting point in a systematic examination of how the humans construct future.

  15. Rotational Doppler Effect: A Probe for Molecular Orbitals Anisotropy.

    Science.gov (United States)

    Miao, Quan; Travnikova, Oksana; Gel'mukhanov, Faris; Kimberg, Victor; Sun, Yu-Ping; Thomas, T Darrah; Nicolas, Christophe; Patanen, Minna; Miron, Catalin

    2015-05-01

    The vibrationally resolved X-ray photoelectron spectra of X2Σg+(3σg−1) and B2Σu+(2σu−1) states of N2+ were recorded for different photon energies and orientations of the polarization vector. Clear dependencies of the spectral line widths on the X-ray polarization as well as on the symmetry of the final electronic states are observed. Contrary to the translational Doppler, the rotational Doppler broadening is sensitive to the photoelectron emission anisotropy. On the basis of theoretical modeling, we suggest that the different rotational Doppler broadenings observed for gerade and ungerade final states result from a Young's double-slit interference phenomenon.

  16. Theoretical analysis and experimental verification on optical rotational Doppler effect

    Science.gov (United States)

    Zhou, Hailong; Fu, Dongzhi; Dong, Jianji; Zhang, Pei; Zhang, Xinliang

    2016-05-01

    We present a theoretical model to sufficiently investigate the optical rotational Doppler effect based on modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the difference of mode index between input and output orbital angular momentum (OAM) light, and linear to the rotating speed of spinning object as well. An experiment is carried out to verify the theoretical model. We explicitly suggest that the spatial spiral phase distribution of spinning object determines the frequency content. The theoretical model makes us better understand the physical processes of rotational Doppler effect, and thus has many related application fields, such as detection of rotating bodies, imaging of surface and measurement of OAM light.

  17. The Doppler paradigm and the APEX-EPOS-ORANGE quandary

    CERN Document Server

    Griffin, J J

    1996-01-01

    The experimental detection of the sharp lines of the \\ee Puzzle is viewed as a struggle against Doppler broadening. Gedanken experiments which are realistic in zeroth order of detail are analyzed to show that the ORANGE and EPOS/I geometries select narrower slices of a Doppler broadened line than spherically inclusive (APEX and EPOS/II --like) apparati. Roughly speaking, the latter require event-by-event Doppler reconstruction simply to regain an even footing with the former. This suggests that APEX' or EPOS/II's coincident pair distributions must be statistically superior to those of EPOS/I or ORANGE in order to support a comparable inference about sharp structure. Under present circumstances, independent alternative data is invaluable. Therefore, a corroboration of Sakai's 330.1 keV (< 3 keV wide) electron line in few MeV e^+ or e^- bombardments of U and Th targets could prove crucial.

  18. Galileo Probe Doppler Residuals as the Wave-Dynamical Signature of Weakly Stable, Downward-Increasing Stratification in Jupiter's Deep Wind Layer

    Science.gov (United States)

    Allison, Michael; Atkinson, David H.; Hansen, James E. (Technical Monitor)

    2001-01-01

    Doppler radio tracking of the Galileo probe-to-orbiter relay, previously analyzed for its in situ measure of Jupiter's zonal wind at the equatorial entry site, also shows a record of significant residual fluctuations apparently indicative of varying vertical motions. Regular oscillations over pressure depth in the residual Doppler measurements of roughly 1-8 Hz (increasing upward), as filtered over a 134 sec window, are most plausibly interpreted as gravity waves, and imply a weak, but downward increasing static stability within the 5 - 20 bar region of Jupiter's atmosphere. A matched extension to deeper levels of an independent inertial stability constraint from the measured vertical wind shear at 1 - 4 bars is roughly consistent with a static stability of approximately 0.5 K/km near the 20 bar level, as independently detected by the probe Atmospheric Structure Instrument.

  19. The US color Doppler in acute renal failure.

    Science.gov (United States)

    Nori, G; Granata, A; Leonardi, G; Sicurezza, E; Spata, C

    2004-12-01

    Imaging techniques, especially ultrasonography and Doppler, can give an effective assistance in the differential diagnosis of acute renal failure (ARF). An resistance Index (RI) value >0.75 is reported as optimal in attempting differential diagnosis between acute tubular necrosis (ANT) and prerenal ARF. In hepatorenal syndrome (HRS) RIs is very increased. In some renal vasculitis, as nodose panarteritis (PN), hemolytic-uremic syndrome (HUS), thrombotic thrombocytopenic purpura (TTP), parenchymal perfusion is reduced and RI increased. In lupus nephritis the RI values are correlated with creatinine level and normal RI are considered as a good prognostic tool. In acute primitive or secondary glomerulonephritis (GN), RI value is normal, with diffuse parenchymal hypervascularization. In acute crescentic and proliferative GN and tubulo-interstitial disease, color Doppler (CD) and power Doppler (PD) reveal a decreased renal parenchymal perfusion, which correlates with increased RI values. In acute thrombosis of renal artery, US color Doppler (DUS) reveals either an absence of Doppler signal or a tardus-parvus pulse distal to the vascular obstruction. In this situation it is possible to visualize hyperthropic perforating vessels that redirect their flow from the capsular plexus to the renal parenchyma. In acute thrombosis of the renal vein Doppler analysis of parenchymal vessels reveals remarkable RI values, sometimes with reversed diastolic flow. In postrenal ARF an adjunct to the differentiation between obstruction and non obstructive dilatation can be found through RIs. Diagnostic criteria of obstruction as reported by literature are: RI>0.70 in the obstructed kidney and, mostly, a difference in RI between the 2 kidneys >0.06-0.1.

  20. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Bo Yun; Lee, Jae Young; Chu, A Jung; Kim, Se Hyung; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-01-15

    The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds) and conventional (231±117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds) required a shorter time than conventional Doppler US (381±133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up.

  1. A review of Doppler ultrasound quality assurance protocols and test devices.

    Science.gov (United States)

    Browne, Jacinta E

    2014-11-01

    In this paper, an overview of Doppler ultrasound quality assurance (QA) testing will be presented in three sections. The first section will review the different Doppler ultrasound parameters recommended by professional bodies for use in QA protocols. The second section will include an evaluation and critique of the main test devices used to assess Doppler performance, while the final section of this paper will discuss which of the wide range of test devices have been found to be most suitable for inclusion in Doppler QA programmes. Pulsed Wave Spectral Doppler, Colour Doppler Imaging QA test protocols have been recommended over the years by various professional bodies, including the UK's Institute of Physics and Engineering in Medicine (IPEM), the American Institute for Ultrasound in Medicine (AIUM), and the International Electrotechnical Commission (IEC). However, despite the existence of such recommended test protocols, very few commercial or research test devices exist which can measure the full range of both PW Doppler ultrasound and colour Doppler imaging performance parameters, particularly quality control measurements such as: (i) Doppler sensitivity (ii) colour Doppler spatial resolution (iii) colour Doppler temporal resolution (iv) colour Doppler velocity resolution (v) clutter filter performance and (vi) tissue movement artefact suppression. In this review, the merits of the various commercial and research test devices will be considered and a summary of results obtained from published studies which have made use of some of these Doppler test devices, such as the flow, string, rotating and belt phantom, will be presented.

  2. Miniature Laser Doppler Velocimeter for Measuring Wall Shear

    Science.gov (United States)

    Gharib, Morteza; Modarress, Darius; Forouhar, Siamak; Fourguette, Dominique; Taugwalder, Federic; Wilson, Daniel

    2005-01-01

    A miniature optoelectronic instrument has been invented as a nonintrusive means of measuring a velocity gradient proportional to a shear stress in a flow near a wall. The instrument, which can be mounted flush with the wall, is a variant of a basic laser Doppler velocimeter. The laser Doppler probe volume can be located close enough to the wall (as little as 100 micron from the surface) to lie within the viscosity-dominated sublayer of a turbulent boundary layer. The instrument includes a diode laser, the output of which is shaped by a diffractive optical element (DOE) into two beams that have elliptical cross sections with very high aspect ratios.

  3. Aerial ultrasonic micro Doppler sonar detection range in outdoor environments.

    Science.gov (United States)

    Bradley, Marshall; Sabatier, James M

    2012-03-01

    Current research demonstrates that micro Doppler sonar has the capability to uniquely identify the presence of a moving human, making it an attractive component in surveillance systems for border security applications. Primary environmental factors that limit sonar performance are two-way spreading losses, ultrasonic absorption, and backscattered energy from the ground that appears at zero Doppler shift in the sonar signal processor. Spectral leakage from the backscatter component has a significant effect on sonar performance for slow moving targets. Sonar performance is shown to rapidly decay as the sensor is moved closer to the ground due to increasing surface backscatter levels.

  4. Optical Doppler tomography based on a field programmable gate array

    DEFF Research Database (Denmark)

    Larsen, Henning Engelbrecht; Nilsson, Ronnie Thorup; Thrane, Lars

    2008-01-01

    We report the design of and results obtained by using a field programmable gate array (FPGA) to digitally process optical Doppler tomography signals. The processor fits into the analog signal path in an existing optical coherence tomography setup. We demonstrate both Doppler frequency and envelope...... extraction using the Hilbert transform, all in a single FPGA. An FPGA implementation has certain advantages over general purpose digital signal processor (DSP) due to the fact that the processing elements operate in parallel as opposed to the DSP. which is primarily a sequential processor....

  5. Experimental Verification of Doppler Effect with the Refraction Method

    Institute of Scientific and Technical Information of China (English)

    Lie FENG; Jia-bi CHEN; Jing-bin HU; Song-lin ZHUANG

    2010-01-01

    The traditional methad of measuring Dopplr Effect is either reflection or dispersion.This article clarifies that it can also verify the Doppler Effect with the refraction method.We have designed the experimental system with the method of optical heterodyne,using the refraction light beam from a prism,and made the experiment.The experimental results are in accordance with the theoreticai calculation.It is very useful in some particular case,such as in Negative-Index Materials(NIM),to verify the Doppler Effect with this method.

  6. Multigroup Free-atom Doppler-broadening Approximation. Theory

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Mark Girard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-06

    Multigroup cross sections at a one target temperature can be Doppler-broadened to multigroup cross sections at a higher target temperature by matrix multiplication if the group structure suf- ficiently resolves the original temperature continuous energy cross section. Matrix elements are the higher temperature group weighted averages of the integral over the lower temperature group boundaries of the free-atom Doppler-broadening kernel. The results match theory for constant and 1/v multigroup cross sections at 618 lanl group structure resolution.

  7. Single pass Doppler positioning for Search and Rescue satellite missions

    Science.gov (United States)

    Schmid, P. E.; Vonbun, F. O.; Lynn, J. J.

    1976-01-01

    This paper describes the implementation of beacon location experiments involving the NASA Nimbus-6 and the Amateur Satellite Corporation (AMSAT) Oscar-6 and Oscar-7 spacecraft. The purpose of these experiments is to demonstrate the feasibility of determining the geographical location of a low power VHF 'distress beacon' via satellite. Doppler data collected during satellite passes is reduced in a mini-computer by means of a simple algorithm resulting in the simultaneous recovery of the unknown receiver coordinates and the unknown Doppler bias frequency. Results indicate point positioning to within a few kilometers - which is within the required accuracies for the positioning of downed aircraft for Search/Rescue missions.

  8. Quality Assurance Training Tracking (QATTS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Quality Assurance Training Tracking System (QATTS) which tracks Quality Assurace training given by R7 QA staff to in-house...

  9. Thermal Tracking of Sports Players

    DEFF Research Database (Denmark)

    Gade, Rikke; Moeslund, Thomas B.

    2014-01-01

    We present here a real-time tracking algorithm for thermal video from a sports game. Robust detection of people includes routines for handling occlusions and noise before tracking each detected person with a Kalman filter. This online tracking algorithm is compared with a state-of-the-art offline...... approach. Furthermore, the combined detection and tracking algorithm runs in real time at 33 fps, even with large image sizes of 1920 × 480 pixels....

  10. Doppler tomography of the Double periodic variable HD 170582 at low and high stage

    Science.gov (United States)

    Mennickent, R. E.; Zharikov, S.; Cabezas, M.; Djurašević, G.

    2016-09-01

    HD 170582 is an interacting binary of the double periodic variable (DPV) type, showing ellipsoidal variability with a period of 16.87 d along with a long photometric cycle of 587 d. It was recently studied by Mennickent et al., who found a slightly evolved B-type star surrounded by a luminous accretion disc fed by a Roche lobe overflowing A-type giant. Here we extend their analysis presenting new spectroscopic data and studying the Balmer emission lines. We find orbitally modulated double-peak Hα and Hβ emissions whose strength also vary in the long term. In addition, Doppler maps of the emission lines reveal sites of enhanced line emission in the first and fourth velocity quadrants, the first one consistent with the position of one of the bright zones detected by the light-curve analysis. We find a difference between Doppler maps at high and low stage of the long cycle; evidence that the emission is optically thicker at high state in the stream-disc impact region, possibly reflecting a larger mass transfer rate. We compare the system parameters with a grid of synthetic binary evolutionary tracks and find the best-fitting model. The system is found to be semi-detached, in a conservative Case-B mass transfer stage, with age 7.68 × 107 yr and mass transfer rate 1.6 × 10-6 M⊙ yr-1. For five well-studied DPVs, the disc luminosity scales with the primary mass and is much larger than the theoretical accretion luminosity.

  11. From speckle tracking echocardiography to torsion: research tool today, clinical practice tomorrow.

    Science.gov (United States)

    Huang, Stephen J; Orde, Sam

    2013-06-01

    Speckle tracking is the latest available technology in echocardiography. However, the technology is still mainly used as a research tool. The potential applications of speckle tracking are many, including cardiac synchronization, regional wall motion analysis, and in the areas of cardiac mechanic studies. This review presents the background theory of speckle tracking echocardiography (STE) and how this technology can be extended to velocity vector analysis, strain, and torsion measurements. The interpretations of these measurements are covered. We also present some potential applications in the critical care setting. Speckle tracking is almost always available in high-end ultrasound machines. The technology has been applied to velocity vector analysis, strain and strain rate measurements, and twist and torsion analysis. Torsion analysis and velocity vector analyses are impossible without using speckle tracking. Speckle tracking-derived strain is superior to tissue Doppler strain because it is angle-independent. A number of studies demonstrated that STE is useful in left and right heart assessments and can be used in assessing preload and afterload. Speckle tracking can be used to measure instantaneous myocardial contractility, strain, and left ventricular torsion. It is still a research tool at present, but shows the promise of being a clinical tool in the future.

  12. Track Initiation for Electro-Optical Tracking of Space Objects

    Science.gov (United States)

    Xu, Z. W.; Wang, X.

    2016-03-01

    Aimed at the track initiation for the electro-optical tracking of space objects, and based on modified Hough transformation, a track initiation algorithm without prior information is proposed to realize the fully robotic identification and tracking of moving objects. The method is valid for the tracking of multi-target as well as with a non-continuous sequence. Simulation shows that the method is effective and applicable for operational usage, and is especially good for the search and discovery of new objects.

  13. Acoustic doppler methods for remote measurements of ocean flows - a review

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The evolution of acoustic doppler methods for remote measurements of ocean flows has been briefly reviewed in historical perspective. Both Eulerian and profiling methods have been discussed. Although the first acoustic Doppler current meter has been...

  14. The track nanotechnology

    Energy Technology Data Exchange (ETDEWEB)

    Waheed, A. [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Physics Department, University of Reading, Reading RG6 6AF (United Kingdom); Forsyth, D., E-mail: dforsyth@bite.ac.u [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Watts, A. [Department of Physics, UCL, London Centre of Nanotechnology (LCN), 17-19 Gordon Street, London WC1H OAH (United Kingdom); Saad, A.F. [Physics Department, Faculty of Science, Garyounis University, Benghazi (Libyan Arab Jamahiriya); Mitchell, G.R. [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Physics Department, University of Reading, Reading RG6 6AF (United Kingdom); Farmer, M. [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Harris, P.J.F. [Physics Department, University of Reading, Reading RG6 6AF (United Kingdom)

    2009-10-15

    The discipline now called Solid State Nuclear Track Detection (SSNTD) dates back to 1958 and has its roots in the United Kingdom. Its strength stems chiefly from factors such as its simplicity, small geometry, permanent maintenance of the nuclear record and other diversified applications. A very important field with exciting applications reported recently in conjuction with the nuclear track technique is nanotechnology, which has applications in biology, chemistry, industry, medicare and health, information technology, biotechnology, and metallurgical and chemical technologies. Nanotechnology requires material design followed by the study of the quantum effects for final produced applications in sensors, medical diagnosis, information technology to name a few. We, in this article, present a review of past and present applications of SSNTD suggesting ways to apply the technique in nanotechnology, with special reference to development of nanostructure for applications utilising nanowires, nanofilters and sensors.

  15. Tracking change over time

    Science.gov (United States)

    ,

    2011-01-01

    Landsat satellites capture images of Earth from space-and have since 1972! These images provide a long-term record of natural and human-induced changes on the global landscape. Comparing images from multiple years reveals slow and subtle changes as well as rapid and devastating ones. Landsat images are available over the Internet at no charge. Using the free software MultiSpec, students can track changes to the landscape over time-just like remote sensing scientists do! The objective of the Tracking Change Over Time lesson plan is to get students excited about studying the changing Earth. Intended for students in grades 5-8, the lesson plan is flexible and may be used as a student self-guided tutorial or as a teacher-led class lesson. Enhance students' learning of geography, map reading, earth science, and problem solving by seeing landscape changes from space.

  16. Tracking migrating birds

    DEFF Research Database (Denmark)

    Willemoes, Mikkel

    and many experiments are only becoming possible with the current development of tracking technologies. During this thesis work I have been tracking the poorly known movements of several species of long-distance migrants and document highly complex migration patterns. In three manuscripts these movements......Migratory movements of birds has always fascinated man and led to many questions concerning the ecological drivers behind, the necessary adaptations and the navigational abilities required. However, especially for the long-distance migrants, basic descriptions of their movements are still lacking...... habitats with those in rural habitats. Some species have decreased the frequency of migrants and migration distance in urban environments, and others have not. The other manuscript describes the small scale movements of three different Palaearctic migrants during winter in Africa in a farmland habitat...

  17. Structural Sparse Tracking

    KAUST Repository

    Zhang, Tianzhu

    2015-06-01

    Sparse representation has been applied to visual tracking by finding the best target candidate with minimal reconstruction error by use of target templates. However, most sparse representation based trackers only consider holistic or local representations and do not make full use of the intrinsic structure among and inside target candidates, thereby making the representation less effective when similar objects appear or under occlusion. In this paper, we propose a novel Structural Sparse Tracking (SST) algorithm, which not only exploits the intrinsic relationship among target candidates and their local patches to learn their sparse representations jointly, but also preserves the spatial layout structure among the local patches inside each target candidate. We show that our SST algorithm accommodates most existing sparse trackers with the respective merits. Both qualitative and quantitative evaluations on challenging benchmark image sequences demonstrate that the proposed SST algorithm performs favorably against several state-of-the-art methods.

  18. CW Projectile Tracking Range Analysis

    Science.gov (United States)

    1989-12-01

    recording of the raw data for later analysis. The doppler signal is then fed into the square-law detector. The output of the square-law detector oscillates ...signal input to the comparator is oscillating at twice the doppler frequency. Within each cycle of the signal, the portion rising above the threshold level...Lan Taiwan. R.O.C. 8. Chung-Cheng Institute of Technology. Main Libraryv P.O. Box S243., Ta-l, 33500. lao-Yuan Taiwan. R.O.C. 9. Yen-Churi Fene 𔄁

  19. Issues in Target Tracking

    Science.gov (United States)

    2010-05-01

    the CUSUM (Page) test yields the quickest detection of a change of distribution for the case of i.i.d. observations [3]. In fact, in a (highly...11. Autocorrelation of the CUSUM increments, sn, under H1 (target present). Issues in Target Tracking RTO-EN-SET-157(2010...restrictive condition that the increments of the cumulative sum, sn, be i.i.d. [3], [22]. Fig. 11 plots the autocorrelation of the CUSUM increments as a

  20. Tracking Online Trails

    Science.gov (United States)

    Qi, Man; Edgar-Nevill, Denis; Wang, Yongquan; Xu, Rongsheng

    Traceability is a key to the investigation of the internet criminal and a cornerstone of internet research. It is impossible to prevent all internet misuse but may be possible to identify and trace the users, and then take appropriate action. This paper presents the value of traceability within the email/-newsposting utilities, the technologies being using to hide identities, the difficulties in locating the traceable data and the challenges in tracking online trails.

  1. Tracking theories of knowledge

    Directory of Open Access Journals (Sweden)

    Adams, Fred

    2005-01-01

    Full Text Available As teorias epistemológicas do rastreamento sustentam que o conhecimento é uma relação real entre o agente cognitivo e seu ambiente. Os estados cognitivos de um agente epistêmico fazem o rastreamento da verdade das proposições que são objeto de conhecimento ao embasarem a crença em indicadores confiáveis da verdade (evidência, razões, ou métodos de formação de crença. A novidade nessa abordagem é que se dá pouca ênfase no tipo de justificação epistêmica voltada ao fornecimento de procedimentos de decisão doxástica ou regras de responsabilidade epistêmica. Este artigo oferece um pouco da história das teorias de rastreamento e, então, defende-as contra muitas objeções que se pretendem (equivocadamente refutadoras dessas teorias. Tracking theories of knowledge maintain that knowledge is a real relation between cognitive agent and environment. Cognitive states of a knower track the truth of known propositions by basing belief on reliable indicators of truth (evidence, reasons, or belief forming methods. The novelty of this approach is that it places little emphasis on epistemic justification of a kind that aims at guiding epistemic agents by giving doxastic decision procedures or rules of epistemic responsibility. This paper gives some of the history of tracking theories, and then defends them against many of the objections most often judged (mistakenly to refute tracking theories.

  2. Registration and Tracking Report

    Science.gov (United States)

    2006-02-01

    the layer ownership probabilities are maximized. Isard and MacCormick [71] propose joint modelling of the background and foreground regions for...gradients. Isard et. al [71] define the object state in terms of spline shape parameters and affine motion parameters. The measurements consist of image...Conference on Automatic Face and Gesture Recognition May 17 - 19, 2004 Seoul, Korea 86 [7] Michael Isard , Andrew Blake, ”Condensation Tracking By

  3. BESⅢ track fitting algorithm

    Institute of Scientific and Technical Information of China (English)

    WANG Ji-Ke; MAO Ze-Pu; BIAN Jian-Ming; CAO Guo-Fu; CAO Xue-Xiang; CHEN Shen-Jian; DENG Zi-Yan; FU Cheng-Dong; GAO Yuan-Ning; HE Kang-Lin; HE Miao; HUA Chun-Fei; HUANG Bin; HUANG Xing-Tao; JI Xiao-Sin; LI Fei; LI Hai-Bo; LI Wei-Dong; LIANG Yu-Tie; LIU Chun-Xiu; LIU Huai-Min; LIU Suo; LIU Ying-Jie; MA Qiu-Mei; MA Xiang; MAO Ya-Jun; MO Xiao-Hu; PAN Ming-Hua; PANG Cai-Ying; PING Rong-Gang; QIN Ya-Hong; QIU Jin-Fa; SUN Sheng-Sen; SUN Yong-Zhao; WANG Liang-Liang; WEN Shuo-Pin; WU Ling-Hui; XIE Yu-Guang; XU Min; YAN Liang; YOU Zheng-Yun; YUAN Chang-Zheng; YUAN Ye; ZHANG Bing-Yun; ZHANG Chang-Chun; ZHANG Jian-Yong; ZHANG Xue-Yao; ZHANG Yao; ZHENG Yang-Heng; ZHU Ke-Jun; ZHU Yong-Sheng; ZHU Zhi-Li; ZOU Jia-Heng

    2009-01-01

    A track fitting algorithm based on the Kalman filter method has been developed for BESⅢ of BEPCⅡ.The effects of multiple scattering and energy loss when the charged particles go through the detector,non-uniformity of magnetic field (NUMF) and wire sag, etc., have been carefully handled.This algorithm works well and the performance satisfies the physical requirements tested by the simulation data.

  4. Energy Tracking Diagrams

    Science.gov (United States)

    Scherr, Rachel E.; Harrer, Benedikt W.; Close, Hunter G.; Daane, Abigail R.; DeWater, Lezlie S.; Robertson, Amy D.; Seeley, Lane; Vokos, Stamatis

    2016-02-01

    Energy is a crosscutting concept in science and features prominently in national science education documents. In the Next Generation Science Standards, the primary conceptual learning goal is for learners to conserve energy as they track the transfers and transformations of energy within, into, or out of the system of interest in complex physical processes. As part of tracking energy transfers among objects, learners should (i) distinguish energy from matter, including recognizing that energy flow does not uniformly align with the movement of matter, and should (ii) identify specific mechanisms by which energy is transferred among objects, such as mechanical work and thermal conduction. As part of tracking energy transformations within objects, learners should (iii) associate specific forms with specific models and indicators (e.g., kinetic energy with speed and/or coordinated motion of molecules, thermal energy with random molecular motion and/or temperature) and (iv) identify specific mechanisms by which energy is converted from one form to another, such as incandescence and metabolism. Eventually, we may hope for learners to be able to optimize systems to maximize some energy transfers and transformations and minimize others, subject to constraints based in both imputed mechanism (e.g., objects must have motion energy in order for gravitational energy to change) and the second law of thermodynamics (e.g., heating is irreversible). We hypothesize that a subsequent goal of energy learning—innovating to meet socially relevant needs—depends crucially on the extent to which these goals have been met.

  5. Fuzzy Logic Particle Tracking

    Science.gov (United States)

    2005-01-01

    A new all-electronic Particle Image Velocimetry technique that can efficiently map high speed gas flows has been developed in-house at the NASA Lewis Research Center. Particle Image Velocimetry is an optical technique for measuring the instantaneous two component velocity field across a planar region of a seeded flow field. A pulsed laser light sheet is used to illuminate the seed particles entrained in the flow field at two instances in time. One or more charged coupled device (CCD) cameras can be used to record the instantaneous positions of particles. Using the time between light sheet pulses and determining either the individual particle displacements or the average displacement of particles over a small subregion of the recorded image enables the calculation of the fluid velocity. Fuzzy logic minimizes the required operator intervention in identifying particles and computing velocity. Using two cameras that have the same view of the illumination plane yields two single exposure image frames. Two competing techniques that yield unambiguous velocity vector direction information have been widely used for reducing the single-exposure, multiple image frame data: (1) cross-correlation and (2) particle tracking. Correlation techniques yield averaged velocity estimates over subregions of the flow, whereas particle tracking techniques give individual particle velocity estimates. For the correlation technique, the correlation peak corresponding to the average displacement of particles across the subregion must be identified. Noise on the images and particle dropout result in misidentification of the true correlation peak. The subsequent velocity vector maps contain spurious vectors where the displacement peaks have been improperly identified. Typically these spurious vectors are replaced by a weighted average of the neighboring vectors, thereby decreasing the independence of the measurements. In this work, fuzzy logic techniques are used to determine the true

  6. Anomaly Detection In Additively Manufactured Parts Using Laser Doppler Vibrometery

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Carlos A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-29

    Additively manufactured parts are susceptible to non-uniform structure caused by the unique manufacturing process. This can lead to structural weakness or catastrophic failure. Using laser Doppler vibrometry and frequency response analysis, non-contact detection of anomalies in additively manufactured parts may be possible. Preliminary tests show promise for small scale detection, but more future work is necessary.

  7. Radar Micro-Doppler classification of Mini-UAVs

    NARCIS (Netherlands)

    Harmanny, R.L.A.; Prémel-Cabic, G.; Wit, J.J.M.

    2015-01-01

    The radar micro-Doppler signature of a target depends on its micro-motion, i.e., the motion of parts of a target relative to the motion of the target as a whole. These micro-motions are very characteristic considering different target classes, e.g., the slow pendulum-like motion of a bird’s wings ve

  8. High-resolution kinetic energy distributions via doppler shift measurements

    Science.gov (United States)

    Xu, Z.; Koplitz, B.; Buelow, S.; Baugh, D.; Wittig, C.

    1986-07-01

    In photolysis/probe experiments using pulsed sources, time delay produces both spatial and directional bias in the fragment distributions, thus enabling well-resolved kinetic energy distributions to be obtained from Doppler shift measurements. Data are presented for H-atoms detected using two-photon ionization, and high S/N and laser-limited kinetic energy resolution are demonstrated.

  9. ATTITUDE RATE ESTIMATION BY GPS DOPPLER SIGNAL PROCESSING

    Institute of Scientific and Technical Information of China (English)

    He Side; Milos Doroslovacki; Guo Zhenyu; Zhang Yufeng

    2003-01-01

    A method is presented for near-Earth spacecraft or aviation vehicle's attitude rate estimation by using relative Doppler frequency shift of the Global Positioning System (GPS)carrier. It comprises two GPS receiving antennas, a signal processing circuit and an algorithm.The whole system is relatively simple, the cost and wcight, as well as power consumption, are very low.

  10. New Type of 2-D Laser Doppler Vibrometer

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The fundamentals and method of 2-D laser Doppler vibrometer are introduced.The factors influencing the measuring accuracy are analyzed. Moreover, the circuit for signal processing is designed. The vibrating amplitude and frequency of 2-D vibration in wider range can be measured simultaneously in non-contact means,the measuring results are accurate.

  11. Diagnostic sensitivity and specificity of Doppler ultrasound in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Terslev, L.; Recke, P. von der; Torp-Pedersen, S.

    2008-01-01

    Objective. To evaluate the sensitivity and specificity of Doppler ultrasound (DUS) in diagnosing arthritis in the wrist and hands, and, if possible, to define a cutoff level for our ultrasound measures for inflammation, resistive index (RI), and color fraction. Methods. Using DUS, 88 patients...

  12. Noise Studies of Externally Dispersed Interferometry for Doppler Velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D J; Edelstein, J; Lloyd, J; Muirhead, P

    2006-05-04

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. Both regular and high-frequency spectral components can be recovered from the data--the moire component carries additional information that increases the signal to noise for velocimetry and spectroscopy. Here we present simulations and theoretical studies of the photon limited Doppler velocity noise in an EDI. We used a model spectrum of a 1600K temperature star. For several rotational blurring velocities 0, 7.5, 15 and 25 km/s we calculated the dimensionless Doppler quality index (Q) versus wavenumber v. This is the normalized RMS of the derivative of the spectrum and is proportional to the photon-limited Doppler signal to noise ratio.

  13. Excitonic Doppler-Rabi Oscillations in a Moving Organic Slab

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    It is theoretically shown that excitonic Doppler-Rabi oscillations can occur in an organic slab moving along the axis of a high-Q cavity. Due to the √N enhancement of the vacuum Rabi frequency, this effect can be more easily observed than that in a moving two-level atom.

  14. Color Doppler in the Assessment of Uteroplacental Circulation Insufficiency

    Directory of Open Access Journals (Sweden)

    Ahmad Soltani Shirazi

    2010-05-01

    Full Text Available Usage of color Doppler ultrasound in the diagnosis of uteroplacental or fetal-placental vascular insufficiency is based on the theory that many of these insufficiencies are due to small vessel disease in the uteroplacental or fetal-placental vasculature which ultimately results in fetal intrauterine growth retardation, increase in prenatal mortality and morbidity and fetal neurological development. "nIn a prospective study on patients who were sus-pected for developing uteroplacental insufficiency, color Doppler ultrasound was done and the results were compared with neonatal weight (one of the most important criteria for IUGR determination which was measured just after delivery."nDirect significant relation was showed to be present between prepartum vascular changes detected in Doppler ultrasound and prognosis of IUGR. "nThree vessel types were assessed in this study:"n1. Umbilical-middle cerebral arteries"n2. Uterine arteries"n3.Venous system (umbilical, ductus venosus, IVC, which is used to assess the compensation process in fetal circulation."nThree Doppler indices of vascular resistance were studied and their abnormalities according to the age of pregnancy were assessed.

  15. Tethered acoustic doppler current profiler platforms for measuring streamflow

    Science.gov (United States)

    Rehmel, Michael S.; Stewart, James A.; Morlock, Scott E.

    2003-01-01

    The U.S. Geological Survey tested and refined tethered-platform designs for measuring streamflow. Platform specifications were developed, radio-modem telemetry of acoustic Doppler current profiler (ADCP) data and potential platform-hull sources were investigated, and hulls were tested and evaluated.

  16. Study of an airborne Doppler radar: Project Asterix

    Science.gov (United States)

    Testud, Jacques; Baudin, F.; Amayenc, P.

    Specifications for an airborne Doppler radar for meteorological applications are given. The following areas are covered: (1) principle for measuring three-dimensional speed field; (2) pulse pattern and detectability; (3) antenna; (4) processing of data; (5) analog system; (6) data control and recording; (7) attitude control and vibrations; and (8) logistics.

  17. Airborne Wind Profiling Algorithm for Doppler Wind LIDAR

    Science.gov (United States)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable airborne Doppler Wind LIDAR system measurements and INS/GPS measurements to be combined to estimate wind parameters and compensate for instrument misalignment. In a further embodiment, the wind speed and wind direction may be computed based on two orthogonal line-of-sight LIDAR returns.

  18. Radar Micro-Doppler classification of Mini-UAVs

    NARCIS (Netherlands)

    Harmanny, R.L.A.; Prémel-Cabic, G.; Wit, J.J.M.

    2015-01-01

    The radar micro-Doppler signature of a target depends on its micro-motion, i.e., the motion of parts of a target relative to the motion of the target as a whole. These micro-motions are very characteristic considering different target classes, e.g., the slow pendulum-like motion of a bird’s wings

  19. Asymmetric micro-Doppler frequency comb generation via magnetoelectric coupling

    Science.gov (United States)

    Filonov, Dmitry; Steinberg, Ben Z.; Ginzburg, Pavel

    2017-06-01

    Electromagnetic scattering from moving bodies, being an inherently time-dependent phenomenon, gives rise to a generation of new frequencies, which can be used to characterize the motion. Whereas an ordinary motion along a linear path produces a constant Doppler shift, an accelerated scatterer can generate a micro-Doppler frequency comb. The spectra produced by rotating objects were studied and observed in a bistatic lock-in detection scheme. The internal geometry of a scatterer was shown to determine the spectrum, and the degree of structural asymmetry was suggested to be identified via signatures in the micro-Doppler comb. In particular, hybrid magnetoelectric particles, showing an ultimate degree of asymmetry in forward and backward scattering directions, were investigated. It was shown that the comb in the backward direction has signatures at the fundamental rotation frequency and its odd harmonics, whereas the comb of the forward scattered field has a prevailing peak at the doubled frequency and its multiples. Additional features of the comb were shown to be affected by the dimensions of the particle and by the strength of the magnetoelectric coupling. Experimental verification was performed with a printed circuit board antenna based on a wire and a split ring, while the structure was illuminated at a 2 GHz carrier frequency. Detailed analysis of micro-Doppler combs enables remote detection of asymmetric features of distant objects and could find use in a span of applications, including stellar radiometry and radio identification.

  20. A simplified study of trans-mitral Doppler patterns

    Directory of Open Access Journals (Sweden)

    Thomas George

    2008-11-01

    Full Text Available Abstract Background Trans-mitral Doppler produces complex patterns with a great deal of variability. There are several confusing numerical measures and indices to study these patterns. However trans-mitral Doppler produces readymade data visualization by pattern generation which could be interpreted by pattern analysis. By following a systematic approach we could create an order and use this tool to study cardiac function. Presentation of the hypothesis In this new approach we eliminate the variables and apply pattern recognition as the main criterion of study. Proper terminologies are also devised to avoid confusion. In this way we can get some meaningful information. Testing the hypothesis Trans-mitral Doppler should be seen as patterns rather than the amplitude. The hypothesis can be proven by logical deduction, extrapolation and elimination of variables. Trans-mitral flow is also analyzed vis-à-vis the Starling's Law applied to the left atrium. Implications of the hypothesis Trans-mitral Doppler patterns are not just useful for evaluating diastolic function. They are also useful to evaluate systolic function. By following this schema we could get useful diagnostic information and therapeutic options using simple pattern recognition with minimal measurements. This simplified but practical approach will be useful in day to day clinical practice and help in understanding cardiac function better. This will also standardize research and improve communication.

  1. A compact differential laser Doppler velocimeter using a semiconductor laser

    NARCIS (Netherlands)

    Jentink, H.W.; Beurden, van J.A.J.; Helsdingen, M.A.; Mul, de F.F.M.; Suichies, H.E.; Aarnoudse, J.G.; Greve, J.

    1987-01-01

    A small differential laser Doppler velocimeter which uses a semiconductor laser and a small number of optical components is described. In this device the light from the laser diode is split into coherent beams by means of a diffraction grating. The two first-order beams are crossed in a probe volume

  2. Laser Doppler velocimetry in Microchannels using integrated optical waveguides.

    NARCIS (Netherlands)

    Pandraud, G.; van den Berg, Albert; Semenov, S.N.

    2000-01-01

    The possibility of laser Doppler velocimetry (LDV) in microchannels, where particles are suspended in a liquid, and where oscillating or evanescent guided coherent light wave is present, is examined theoretically. The conditions for the observation of the transverse and longitudinal collective phore

  3. UTEROPLACENTAL DOPPLER VELOCIMETRY DURING BRAXTON-HICKS CONTRACTIONS

    NARCIS (Netherlands)

    DIJKSTRA, K; AARNOUDSE, JG; Oosterhof, H.

    1992-01-01

    Pulsed-wave Doppler ultrasound was used to evaluate the influence of Braxton Hicks' contractions on flow velocity waveforms in the uterine arteries. Flow velocity waveforms were obtained from a standardized site, at the crossing of the uterine artery with the external iliac artery near the uterine w

  4. Transcranial Doppler for detection of cerebral ischaemia during carotid endarterectomy

    DEFF Research Database (Denmark)

    Jørgensen, L G; Schroeder, T V

    1992-01-01

    We evaluated transcranial Doppler sonography (TCD) for the detection of cerebral ischaemia during carotid endarterectomy in 30 male and 14 female patients with ipsilateral focal cerebro-vascular symptoms. Surgery was performed during halothane-nitrous oxide anaesthesia with moderate hypocapnia...

  5. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H;

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 months...

  6. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan;

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  7. Review of methodological developments in laser Doppler flowmetry

    NARCIS (Netherlands)

    Rajan, Vinayakrishnan; Varghese, Babu; van Leeuwen, Ton; Steenbergen, Wiendelt

    2009-01-01

    Laser Doppler flowmetry is a non-invasive method of measuring microcirculatory blood flow in tissue. In this review the technique is discussed in detail. The theoretical and experimental developments to improve the technique are reviewed. The limitations of the method are elaborated upon, and the re

  8. Venstre ventrikels diastoliske funktion vurderet med transtorakal Doppler-ekkokardiografi

    DEFF Research Database (Denmark)

    Poulsen, S H; Jensen, S E; Gøtzsche, O;

    1996-01-01

    Left ventricular diastolic dysfunction is currently recognized in patients with different heart diseases. Three abnormal filling patterns of the left ventricle detected by pulsed-Doppler echocardiography are observed in patients with heart disease. Each filling pattern is characterised by differe...

  9. Color doppler in diagnosis of pathological changes in blood vessels

    Directory of Open Access Journals (Sweden)

    Mladenović Saša

    2014-01-01

    Full Text Available Color Doppler ultrasound is a method that allows noninvasive imaging of blood flow through a blood vessel and analysis of blood vessels, which can be made to flow disturbance and the presence of plaque and narrowing of the blood vessel. Color Doppler ultrasonography allows early detection of pathological changes in blood vessels, which contributes to adequate preventive and therapeutic procedures in the prevention of cerebrovascular disorders. The aim of this paper is to demonstrate the importance of color Doppler ultrasound blood vessels in the diagnosis of pathological changes in the blood vessels of the neck. To create a work used the material of the Cabinet of color Doppler ultrasonography of the Health Center in Donja Gusterica in a prospective study of a random sample of 60 patients were reviewed in January 2014. Gender analysis examined patients, women were 32 (53.33% and 28 men (46.67%. Looking at the age of examined patients, we have found that most of them 43 (71.67% over the age of 50 years, while we found 17 (28.33% patients under 50 years. Atherosclerotic plaques were diagnosed in 36, a change in the shape of the carotid arteries in 29 patients. Atherosclerotic plaque, we usually find the bifurcation ACC and the Origin ACI in 23 (63.89%. Duplex sonography shows what angioneurologists and vascular surgeons are most interested in: the morphology of arterial lesions and hemodynamic effects.

  10. A Reference Optical System of Laser Doppler Longitudinal Displacement Measurement

    Institute of Scientific and Technical Information of China (English)

    张存满; 赵洋; 李达成

    2001-01-01

    In this paper, a new reference optical system is put forward to achieve longitudinal displacement measurement. An optical grating is used for frequency mixing and getting high SNR signals in the measurement. Conditions and methods for getting Doppler beat signals are presented.The experiments indicate that this optical syetem can be used to measure the longitudinal displacement with high accuracy.

  11. Doppler velocimetry with emphasis on the fetal cerebral circulation

    NARCIS (Netherlands)

    M.J. Noordam (Marja)

    1996-01-01

    textabstractIn this thesis the following questions were addressed: 1. Are changes in placental vascular resistance associated with alterations in arterial down stream impedance at fetal level? To this purpose placental embolization was carried-out in the fetal lamb with subsequent Doppler velocimetr

  12. Complex Doppler effect in left-handed metamaterials

    CERN Document Server

    Ziemkiewicz, David

    2014-01-01

    The Doppler shift is investigated in one-dimensional system with moving source. Theoretical findings are confirmed in numerical simulations of optical and acoustical waves propagation in simple metamaterial model, showing the reversed shift and the existence of multiple frequency modes. The properties of these waves are discussed. The effect of absorption on the phenomenon is outlined.

  13. Augmented Reality Based Doppler Lidar Data Visualization: Promises and Challenges

    Directory of Open Access Journals (Sweden)

    Cherukuru N. W.

    2016-01-01

    As a proof of concept, we used the lidar data from a recent field campaign and developed a smartphone application to view the lidar scan in augmented reality. In this paper, we give a brief methodology of this feasibility study, present the challenges and promises of using AR technology in conjunction with Doppler wind lidars.

  14. Usefulness of Doppler Parameter in Patients with Renal Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Dept. of Radiology, Konyang University Hospital, Daejeon (Korea, Republic of)

    2012-08-15

    The purpose of this study is to assess the usefulness of Doppler parameters in transplanted kidney function. Doppler parameters, including resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end diastolic velocity (EDV) were measured in the interlobar artery of 55 transplant recipients. Patients were grouped according to glomerular filtration rate (GFR): Group A (GFR < 30 ml / min / 1.73 m2, n = 27) and group B (GFR {>=}30 ml / min / 1.73 m2, n = 28). Doppler parameters were compared between groups and correlated with the GFR. GFR (40.1 {+-} 26.9) showed a significant negative correlation with RI (0.69{+-}.08) (p = .002, r = -.414). RI (0.72 vs. 0.67), PI (1.42 vs. 1.23), and EDV (10.5 vs. 15.3) differed significantly between groups (p < .05), however, PSV was not (36.9 vs. 47.1). Patients in group A (n = 11) with a lower RI than the mean had significantly lower PSV (31.7 vs. 45.1; p = .027) and EDV (11.1 vs. 16.7; p .017), compared with such patients in group B (n = 21). Doppler parameters are useful for evaluation of function of transplanted kidney. Even if the RI is normal, PSV and EDV may be used as hemodynamic indicators.

  15. A range-rate extraction unit for determining Doppler effect

    Science.gov (United States)

    1970-01-01

    Active ranging technique devised for VHF or S-band radar systems divides target Doppler frequency by counter-generated number that is proportional to transmitting frequency, thus producing target velocity data in terms of speed and distance relative to target transponder.

  16. How to Study the Doppler Effect with Audacity Software

    Science.gov (United States)

    Dias, Marco Adriano; Carvalho, Paulo Simeão; Ventura, Daniel Rodrigues

    2016-01-01

    The Doppler effect is one of the recurring themes in college and high school classes. In order to contextualize the topic and engage the students in their own learning process, we propose a simple and easily accessible activity, i.e. the analysis of the videos available on the internet by the students. The sound of the engine of the vehicle…

  17. Unidirectional Rotation of Molecules Measured by the Rotational Doppler Effect

    Directory of Open Access Journals (Sweden)

    Prior Yehiam

    2013-03-01

    Full Text Available A pair of linearly polarized pump pulses induce field-free unidirectional molecular rotation, which is detected by a delayed circularly polarized probe. The polarization and spectrum of the probe are modified by the interaction with the molecules, in accordance with the Rotational Doppler Effect.

  18. Determining the Speed of Sound Using the Doppler Effect.

    Science.gov (United States)

    Gagne, Richard.

    1996-01-01

    Presents a simple but effective experiment that uses ultrasonic transducers and some basic electronics to study the speed of sound using the Doppler effect. Eliminates the noise problems associated with most sound experiments. Discusses the theory, and describes the apparatus and procedure. (JRH)

  19. Maternal and fetal Doppler velocimetry in women diagnosed with ...

    African Journals Online (AJOL)

    2016-03-16

    Mar 16, 2016 ... Aim: This study aimed to investigate maternal and fetal Doppler flow parameters in term pregnant women diagnosed with fear of ... [3] A strong association was found between FOC ... and it includes 33 items about women's cognitive appraisal .... acute emotional reactivity during pregnancy can influence.

  20. Doppler Lidar in the Wind Forecast Improvement Projects

    Directory of Open Access Journals (Sweden)

    Pichugina Yelena

    2016-01-01

    Full Text Available This paper will provide an overview of some projects in support of Wind Energy development involving Doppler lidar measurement of wind flow profiles. The high temporal and vertical resolution of these profiles allows the uncertainty of Numerical Weather Prediction models to be evaluated in forecasting dynamic processes and wind flow phenomena in the layer of rotor-blade operation.