WorldWideScience

Sample records for sandwich elisa methods

  1. Validation and comparison of a sandwich ELISA, two competitive ELISAs and a real-time PCR method for the detection of lupine in food.

    Science.gov (United States)

    Ecker, Christina; Ertl, Anna; Pulverer, Walter; Nemes, Albert; Szekely, Pal; Petrasch, Angelika; Linsberger-Martin, Gertrud; Cichna-Markl, Margit

    2013-11-01

    Methods applied in food allergen analysis should be specific, sensitive and applicable to both raw and highly processed foods. The performance of the most commonly used methods, ELISA and real-time PCR, may, however, be influenced by food processing steps, e.g., heat treatment. The present study compares the applicability of four in-house developed methods, one sandwich ELISA, two competitive ELISAs and a real-time PCR method, for the detection of lupine in four different food matrices, comprising bread, biscuits, rice patties and noodles. In order to investigate the influence of food processing on the detectability, not only the heat treated model foods but also the corresponding doughs were analysed. The sandwich ELISA proved to be the most sensitive method. The LOD was found to be 10 ppm lupine, independent from the food matrix and independent if the dough or the heat treated food was analysed. In addition, the methods were applied to the analysis of commercial foodstuffs differing in their labelling. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Sandwich ELISA for quantitative detection of human collagen prolyl 4-hydroxylase

    Directory of Open Access Journals (Sweden)

    Myllyharju Johanna

    2010-06-01

    Full Text Available Abstract Background We describe a method for specific, quantitative and quick detection of human collagen prolyl 4-hydroxylase (C-P4H, the key enzyme for collagen prolyl-4 hydroxylation, in crude samples based on a sandwich ELISA principle. The method is relevant to active C-P4H level monitoring during recombinant C-P4H and collagen production in different expression systems. The assay proves to be specific for the active C-P4H α2β2 tetramer due to the use of antibodies against its both subunits. Thus in keeping with the method C-P4H is captured by coupled to an anti-α subunit antibody magnetic beads and an anti-β subunit antibody binds to the PDI/β subunit of the protein. Then the following holoenzyme detection is accomplished by a goat anti-rabbit IgG labeled with alkaline phosphatase which AP catalyzes the reaction of a substrate transformation with fluorescent signal generation. Results We applied an experimental design approach for the optimization of the antibody concentrations used in the sandwich ELISA. The assay sensitivity was 0.1 ng of C-P4H. The method was utilized for the analysis of C-P4H accumulation in crude cell extracts of E. coli overexpressing C-P4H. The sandwich ELISA signals obtained demonstrated a very good correlation with the detected protein activity levels measured with the standard radioactive assay. The developed assay was applied to optimize C-P4H production in E. coli Origami in a system where the C-P4H subunits expression acted under control by different promoters. The experiments performed in a shake flask fed-batch system (EnBase® verified earlier observations that cell density and oxygen supply are critical factors for the use of the inducer anhydrotetracycline and thus for the soluble C-P4H yield. Conclusions Here we show an example of sandwich ELISA usage for quantifying multimeric proteins. The method was developed for monitoring the amount of recombinant C-P4H tetramer in crude E. coli extracts. Due

  3. Development of indirect sandwich ELISA for determination of excretory-secretory antigens of Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Libertad Alzamora-Gonzales

    2016-05-01

    Full Text Available Fasciolosis is a cosmopolitan parasitosis medical-veterinary importance caused by Fasciola hepatica, which affects sheep, goats and cattle; and it affects man accidentally causing an epidemic-endemic infection difficult to diagnose. The aim was to develop an indirect sandwich ELISA with 3 antibodies for detecting excretory-secretory antigens of Fasciola hepatica (ESFh. For the development of indirect sandwich ELISA were used, as capture antibody, mouse polyclonal antibodies anti ESFh and polyclonal antibodies rabbit anti-ESFh as detection antibody, at the concentrations of 10 and 5 µg/mL respectively. The conjugate used was mouse monoclonal anti- total immunoglobulins rabbit linked to peroxidase (1/1000. Were analized 31 sheep fecal samples, and the results were compared with those obtained by direct coproparasitological examination (DC and counterimmunoelectrophoresis (CIEP. The detection limit obtained for indirect sandwich ELISA was 100 ng/mL. The test had a 100% sensitivity, 96.6% specificity, positive and negative predictive values of 50% and 96.6% respectively, in relation to DC test. Comparing with CIEP the specificity obtained for indirect sandwich ELISA was 93.5% and a negative predictive value of 100%. We concluded that indirect sandwich ELISA designed is able to detect metabolic antigens in ovine feces samples and can be used for Fasciola hepatica diagnosis.

  4. Development of a Sensitive Luciferase-Based Sandwich ELISA System for the Detection of Human Extracellular Matrix 1 Protein.

    Science.gov (United States)

    Li, Ya; Li, Yanqing; Zhao, Junli; Zheng, Xiaojing; Mao, Qinwen; Xia, Haibin

    2016-12-01

    Enzyme-linked immunosorbent assay (ELISA) has been one of the main methods for detecting an antigen in an aqueous sample for more than four decades. Nowadays, one of the biggest concerns for ELISA is still how to improve the sensitivity of the assay, and the luciferase-luciferin reaction system has been noticed as a new detection method with high sensitivity. In this study, a luciferin-luciferase reaction system was used as the detection method for a sandwich ELISA system. It was shown that this new system led to an increase in the detection sensitivity of at least two times when compared with the traditional horseradish peroxidase (HRP) detection method. Lastly, the serum levels of the human extracellular matrix 1 protein of breast cancer patients were determined by the new system, which were overall similar to the HRP chemiluminescent system. Furthermore, this new luciferase reporter can be implemented into other ELISA systems for the purpose of increasing the assay sensitivity.

  5. Perbedaan Metode ELISA Sandwich A dan B dalam Deteksi Antigen Membran Toxoplasma gondii

    Directory of Open Access Journals (Sweden)

    ADI PRAYITNO

    2004-11-01

    Full Text Available Spreading of toxoplasmosis to fetus can by placenta, so it caused theabortion, born dead or congenital defect. To diagnosis this disease for fixed the acute infection must get the significant increasing of IgG by the soft fee. The objections of this study are to know the difference between ELISA Sandwich A and B in detecting of membrane antigen of Toxoplasma gondii (T. gondii in placenta tissue of pregnant women three-semester I and II with spontaneous abortion in Surakarta. One hundred serum and placenta tissue samples of pregnant women three-semester I and II with spontaneous abortion are got from dr. Muwardi Hospital. IgM anti Toxo from serum was examined by Toxo ISAGA Kit and IgG anti Toxo by Toxo Screen DA Kit. Detecting of membrane antigen of T. goodie from placenta tissue were done by ELISA Sandwich A and B. The result of this experiment showed that 33% were positive IBM and or Gig anti Toxo. Detection of membrane antigen toward 33 samples with positive Toxo (IgG positive was highly significant different between ELISA Sandwich A (3% positive toward ELISA Sandwich B (72.7% positive.

  6. A highly sensitive sandwich ELISA for the determination of glycomacropeptide to detect liquid whey in raw milk

    OpenAIRE

    Chávez, Norma A.; Jauregui, Juan; Palomares, Laura A.; Macías, Karla E.; Jiménez, Mariela; Salinas, Eva

    2012-01-01

    Milk processing industries and distributors have problems with adulteration of liquid milk by the addition of bovine cheese whey. Recently, the detection of fraudulent manipulation of milk with whey has focused on the identification of glycomacropeptide (GMP). Current non-immunological methods to detect GMP in dairy products are expensive and time-consuming or have low sensitivity. In this study, a novel sandwich enzyme-linked immunosorbent assay (ELISA) for the detection and quantification o...

  7. Development of a double-antibody sandwich ELISA for rapid detection of Bacillus Cereus in food

    Science.gov (United States)

    Zhu, Longjiao; He, Jing; Cao, Xiaohan; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-01-01

    Bacillus cereus is increasingly recognized as one of the major causes of food poisoning in the industrialized world. In this paper, we describe a sensitive double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) that was developed for rapid detection of B. cereus in food to minimize the risk of contamination. The polyclonal antibody (pAb) and monoclonal antibodies (mAbs) specific to B. cereus were generated from rabbit antiserum and mouse ascites, respectively, using the octanoic acid/saturated ammonium sulfate precipitation method and protein A-sepharose columns. IgG-isotype mAbs were specially developed to undergo a novel peripheral multiple sites immunization for rapid gain of hybridomas and a subtractive screen was used to eliminate cross reactivity with closely related species such as Bacillus thuringiensis, B. subtilis, B. licheniformis and B. perfringens. The linear detection range of the method was approximately 1 × 104–2.8 × 106 cells/mL with a detection limit (LOD) of 0.9 × 103 cells/mL. The assay was able to detect B. cereus when the samples were prepared in meat with various pathogens. The newly developed analytical method provides a rapid method to sensitively detect B. cereus in food specimens. PMID:26976753

  8. Development and evaluation of a double antibody sandwich ELISA for the detection of human sDC-SIGN.

    Science.gov (United States)

    Chen, Shang-Liang; Li, Yan-Li; Tang, Yuan; Chen, Zhi-Cheng; Zhou, Jing; Zhou, Jia; Lu, Xiao; Zhao, Na; Chen, Zheng-Liang; Zuo, Daming

    2016-09-01

    sDC-SIGN is the soluble form of dendritic cell-specific intercellular adhesion molecule-3-grabbing non-integrin (DC-SIGN, CD209), which is a molecule involved with pathogen recognition and immune regulation. However, there is no commercially available ELISA kit for detecting human sDC-SIGN, and the normal range of this molecule is unknown. Here, we describe an ELISA for detecting human sDC-SIGN with high specificity. First, sDC-SIGN protein was expressed and purified. Monoclonal and polyclonal antibodies were then raised against the purified protein and subsequently characterized. A sandwich ELISA was developed using polyclonal antibodies specific for sDC-SIGN for capture and a biotin-labeled monoclonal antibody specific for sDC-SIGN for detection of protein. This method has sensitivity up to 0.2 ng/ml. Using this ELISA, we found that the concentration of sDC-SIGN in sera of healthy volunteers ranges from 0-319 ng/ml with a mean concentration of 27.14 ng/ml. Interestingly, the concentration of sDC-SIGN in sera from patients with cancer or chronic hepatitis B virus (CHB) infection was lower than that of health controls. The mean concentrations of sDC-SIGN in cancer patients and chronic hepatitis B virus infection patients were 3.2 ng/ml and 3.8 ng/ml, respectively. We developed a sandwich ELISA for detecting human sDC-SIGN and demonstrated its use by assessing sera concentrations of sDC-SIGN in patients with cancer and chronic CHB infection compared to that of healthy controls. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development of a Monoclonal Antibody-Based Sandwich ELISA for Peanut Allergen Ara h 1 in Food

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-07-01

    Full Text Available We have established a highly sensitive sandwich enzyme-linked immunosorbent assay (ELISA based on two monoclonal antibodies (mAb to measure the content of the major peanut allergen Ara h 1 in foods. Two mAbs were selected out of 12 murine hybridoma cells secreting Ara h 1-specific antibody. Using mAb 6 as the capture antibody and HRP-labelled mAb 4 as the detection antibody, the limit of detection (LOD the assay was 0.34 ng/mL. Cross-reaction analysis showed that this method was strongly specific and had no cross-reactions with Ara h 2, pea protein or soy protein. Sample analysis showed that this ELISA was a useful tool to monitor peanut allergens in food products by measuring Ara h 1 content.

  10. Development of a Monoclonal Antibody-Based Sandwich ELISA for Peanut Allergen Ara h 1 in Food

    Science.gov (United States)

    Peng, Juan; Song, Shanshan; Xu, Liguang; Ma, Wei; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2013-01-01

    We have established a highly sensitive sandwich enzyme-linked immunosorbent assay (ELISA) based on two monoclonal antibodies (mAb) to measure the content of the major peanut allergen Ara h 1 in foods. Two mAbs were selected out of 12 murine hybridoma cells secreting Ara h 1-specific antibody. Using mAb 6 as the capture antibody and HRP-labelled mAb 4 as the detection antibody, the limit of detection (LOD) the assay was 0.34 ng/mL. Cross-reaction analysis showed that this method was strongly specific and had no cross-reactions with Ara h 2, pea protein or soy protein. Sample analysis showed that this ELISA was a useful tool to monitor peanut allergens in food products by measuring Ara h 1 content. PMID:23880725

  11. Development of a sandwich ELISA for quantification of immunoglobulin G in mink blood

    DEFF Research Database (Denmark)

    Mathiesen, Ronja; Chriél, Mariann; Struve, T.

    A major concern amongst the Danish mink farmers is the incidence of the syndrome pre-weaning diarrhea. The syndrome causes major management issues and decreases the welfare of the mink and increases mortality in the pre-weaning period. The etiology of the syndrome is considered multifactorial...... as a specific cause is not fully established or understood. Adding to an increased risk of developing pre-weaning diarrhea is the fact that the mink kits are born with very low levels of circulating immunoglobulins. Rapid achievement of high levels of immunoglobulins in the bloodstream is essential for the kits...... early immunity and thus their resistance against pathogenic agents found in the environment. This study describes a sandwich ELISA for quantification of the concentration of total immunoglobulin G in mink blood. The ELISA was validated with serum samples from females (n=8) and their kits (litters of 4...

  12. Development of a monoclonal sandwich ELISA for direct detection of bluetongue virus 8 in infected animals.

    Science.gov (United States)

    Ten Haaf, Andre; Kohl, Johannes; Pscherer, Sibylle; Hamann, Hans-Peter; Eskens, Hans Ulrich; Bastian, Max; Gattenlöhner, Stefan; Tur, Mehmet Kemal

    2017-05-01

    Bluetongue is an infectious viral disease which can cause mortality in affected ruminants, and tremendous economic damage via impacts upon fertility, milk production and the quality of wool. The disease is caused by bluetongue virus (BTV) which is transmitted by species of Culicoides biting midge. Rapid detection of BTV is required to contain disease outbreaks and reduce economic losses. The purpose of this study was to develop a monoclonal sandwich ELISA for direct detection of BTV in infected animals. Phage display technology was used to isolate BTV specific antibody fragments by applying the human scFv Tomlinson antibody libraries directly on purified BTV-8 particles. Three unique BTV-8 specific human antibody fragments were isolated which were able to detect purified BTV particles and also BTV in serum of an infected sheep. A combination of a human/mouse scFv-Fc chimeric fusion protein and a human Fab fragment in a sandwich ELISA format was able to detect BTV specifically with a limit of detection (LOD) of 10(4) infectious virus particles, as determined by tissue culture titration. This approach provided pilot data towards the development of a novel diagnostic test that might be used for direct detection of BTV-8 particles. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Evaluation of a polyclonal antibody based sandwich ELISA for the detection of faecal antigens in Schistosoma spindale infection in bovines.

    Science.gov (United States)

    Sreenivasa Murthy, G S; D'Souza, Placid E; Shrikrishna Isloor, K

    2013-04-01

    Schistosomosis is a common parasitic infection in animals prevalent in cattle in Asia and Africa, where it is estimated that at least 165 million animals are infected. Out of the 10 species reported to naturally infect cattle only Schistosoma nasale and Schistosoma spindale have received particular attention, because of their recognized veterinary significance. Although animal schistosomes may, under rare conditions favouring intensive transmission, act as important pathogens in endemic areas occur at a subclinical level, causing significant losses due to long term effects on animal growth and productivity. The detection of Schistosoma antigens in serum or stool could be more valuable in diagnosis, hence early treatment before irreparable damage. In this study, fresh adult worms of S. spindale were collected from the mesenteric blood vessels, whole worm antigen was prepared. These were immunized to rabbit and guinea pig to raise antibodies against S. spindale. Polyclonal antibodies of rabbit are further used as primary capture antibodies to coat ELISA plates. The capture of antibodies of guinea pig was conjugation with horse reddish peroxidase was used as secondary antibodies. Sandwich ELISA was performed to detect Schistosoma antigens in faecal samples collected from a total of 86 infected cattle and buffaloes. The working dilutions of capture antibody, detecting antibody and conjugate were found to be 1:32, 1:20 and 1:5,000 respectively by checker board titration method. The dilution of faecal supernatant antigens of S. spindale antibodies was 1:80. Out of 86 faecal samples, 77 samples were positive by Sandwich ELISA indicating 89.54 % infection. Where as in control samples none of the samples was positive. In mixed infection out of 20 samples positive for fasciola, amphistome and hydatid, Out of 20 samples 2 samples were positive indicating 10 % infection rate. The overall sensitivity of this test is 88.65 % and specificity was 90.90 %. It could be concluded

  14. Differentiation of Foot-and-Mouth Disease-Infected pigs from Vaccinated Pigs Using Antibody-Detecting Sandwich ELISA

    NARCIS (Netherlands)

    Chen, T.H.; Lee, F.; Lin, Y.L.; Dekker, A.; Chung, W.B.; Pan, C.H.; Jong, M.H.; Huang, C.C.; Lee, M.C.; Tsai, H.J.

    2011-01-01

    The presence of serum antibodies for nonstructural proteins of the foot-and-mouth disease virus (FMDV) can differentiate FMDV-infected animals from vaccinated animals. In this study, a sandwich ELISA was developed for rapid detection of the foot-and-mouth disease (FMD) antibodies; it was based on an

  15. A High-Throughput, Precipitating Colorimetric Sandwich ELISA Microarray for Shiga Toxins

    Directory of Open Access Journals (Sweden)

    Andrew Gehring

    2014-06-01

    Full Text Available Shiga toxins 1 and 2 (Stx1 and Stx2 from Shiga toxin-producing E. coli (STEC bacteria were simultaneously detected with a newly developed, high-throughput antibody microarray platform. The proteinaceous toxins were immobilized and sandwiched between biorecognition elements (monoclonal antibodies and pooled horseradish peroxidase (HRP-conjugated monoclonal antibodies. Following the reaction of HRP with the precipitating chromogenic substrate (metal enhanced 3,3-diaminobenzidine tetrahydrochloride or DAB, the formation of a colored product was quantitatively measured with an inexpensive flatbed page scanner. The colorimetric ELISA microarray was demonstrated to detect Stx1 and Stx2 at levels as low as ~4.5 ng/mL within ~2 h of total assay time with a narrow linear dynamic range of ~1–2 orders of magnitude and saturation levels well above background. Stx1 and/or Stx2 produced by various strains of STEC were also detected following the treatment of cultured cells with mitomycin C (a toxin-inducing antibiotic and/or B-PER (a cell-disrupting, protein extraction reagent. Semi-quantitative detection of Shiga toxins was demonstrated to be sporadic among various STEC strains following incubation with mitomycin C; however, further reaction with B-PER generally resulted in the detection of or increased detection of Stx1, relative to Stx2, produced by STECs inoculated into either axenic broth culture or culture broth containing ground beef.

  16. Diagnostic efficacy of monoclonal antibody based sandwich enzyme linked immunosorbent assay (ELISA for detection of Fasciola gigantica excretory/secretory antigens in both serum and stool

    Directory of Open Access Journals (Sweden)

    Zoheiry Mona K

    2011-09-01

    Full Text Available Abstract Background This research was carried out to develop a reliable monoclonal antibody (MoAb-based sandwich enzyme linked immunosorbent assay (ELISA for the diagnosis of active Fasciola gigantica infection in both serum and stool for comparative purposes. Methods From a panel of MoAbs raised against F. gigantica excretory/secretory antigens (ES Ags, a pair (12B/11D/3F and 10A/9D/10G was chosen due to its high reactivity and strict specificity to F. gigantica antigen by indirect ELISA. Results The two MoAbs were of the IgG1 and IgG2a subclasses, respectively. Using SDS-PAGE and EITB, the selected MoAbs recognized 83, 64, 45 and 26 kDa bands of ES Ags. The lower detection limit of ELISA assay was 3 ng/ml. In stool, the sensitivity, specificity and diagnostic efficacy of ELISA was 96%, 98.2 and 97.1%; while in serum they were 94%, 94.6% and 94.3%, respectively. Moreover, a positive correlation was found between ova count in stool of F. gigantica infected patients and the OD readings of ELISA in both stool and serum samples (r = 0.730, p Conclusions These data showed that the use of MoAb-based sandwich ELISA for the detection of F. gigantica coproantigens in stool specimens was superior to serum samples; it provides a highly efficient, non-invasive technique for the diagnosis of active F. gigantica infection.

  17. Novel sandwich ELISAs for rat DMP1: age-related decrease of circulatory DMP1 levels in male rats.

    Science.gov (United States)

    Sato, Sunao; Hashimoto, Jun; Usami, Yu; Ohyama, Kaname; Isogai, Yukihiro; Hagiwara, Yoshiaki; Maruyama, Nobuhiro; Komori, Toshihisa; Kuroda, Tatsuhiko; Toyosawa, Satoru

    2013-12-01

    Dentin matrix protein 1 (DMP1), a noncollagenous bone matrix protein produced by osteocytes, regulates matrix mineralization and phosphate homeostasis. The lack of a precise assay for circulating DMP1 levels impairs further investigation of the protein's biological significance. Because full-length precursor DMP1 is cleaved into NH2- and COOH-terminal fragments during the secretory process, we developed two new sandwich ELISAs for the NH2- and COOH-terminal fragments of rat DMP1. One of these ELISAs, ELISA 1-2, is based on two affinity-purified polyclonal antibodies against the DMP1-1 and DMP1-2 peptides of the NH2-terminal fragment, whereas the other, ELISA 4-3, is based on two affinity-purified polyclonal antibodies against the DMP1-3 and DMP1-4 peptides of the COOH-terminal fragment. The polyclonal antibodies were characterized in immunohistochemical and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS) studies. Immunohistochemical analyses of rat bone using these polyclonal antibodies revealed DMP1 immunoreactivity in osteocytes and pericanalicular matrix, consistent with the previously reported osteocyte-specific expression of DMP1. LC-MS/MS analyses of rat plasma-derived immunoreactive products affinity-extracted with these antibodies revealed the presence of DMP1 in circulating blood. The ELISAs established with these antibodies met accepted standards for reproducibility, repeatability, precision, and accuracy. Circulating DMP1 and levels of other biochemical markers (osteocalcin, Trap5b, Dkk-1, and SOST) were measured in 2-, 4-, 8-, 12-, 18-, 24-, 72-, and 96-week-old Wistar male rats. Circulating DMP1 levels determined by ELISAs 1-2 and 4-3 significantly decreased with age. During rapid skeletal growth (2-12weeks), DMP1 levels measured by ELISA 4-3 were over three times higher than those measured by ELISA 1-2; however, DMP1 levels in old animals (72 and 96weeks) were almost the same when measured by either ELISA. DMP1 levels

  18. A highly sensitive sandwich ELISA for the determination of glycomacropeptide to detect liquid whey in raw milk.

    Science.gov (United States)

    Chávez, Norma A; Jauregui, Juan; Palomares, Laura A; Macías, Karla E; Jiménez, Mariela; Salinas, Eva

    2012-03-01

    Milk processing industries and distributors have problems with adulteration of liquid milk by the addition of bovine cheese whey. Recently, the detection of fraudulent manipulation of milk with whey has focused on the identification of glycomacropeptide (GMP). Current non-immunological methods to detect GMP in dairy products are expensive and time-consuming or have low sensitivity. In this study, a novel sandwich enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of whey in raw milk was developed, using a polyclonal rabbit anti-GMP antibody. Calibration curves were constructed by analyzing raw milk standards containing different known concentrations of liquid cheese whey (0.02-20%). The method had a detection limit of 0.047% (v/v) and a quantification limit of 0.14% (v/v). The antibody showed high specificity and no cross-reaction with milk components (other than κ-casein) and was successful in detecting GMP in dairy commercial products. The recovery ratio was between 95.62% and 113.88% for all matrices tested. The intra-assay and interassay coefficients of variation were <6% and <7%, respectively. Finally, it can be stored for 3 months in the form of a ready-to-use kit, while maintaining its accuracy and reproducibility.

  19. A sandwich ELISA for the detection of bluetongue virus in cell culture using antiserum against the recombinant VP7 protein

    Directory of Open Access Journals (Sweden)

    Karam Chand

    2009-09-01

    Full Text Available A polyclonal antibody-based sandwich enzyme-linked immunosorbent assay (s-ELISA was developed for the detection of bluetongue virus (BTV. The test used antiserum against BTV and antiserum against the bluetongue (BT core protein. The antiserum against the virus was used as a capture antibody and the antiserum against the protein was used for detection. In this study, antiserum to recombinant viral protein 7 (rVP7 was used as a detection antibody in place of anti-core antiserum. The assay was used to detect the BT serotypes found in India, namely: 1, 2, 9, 15, 18 and 23. The modified sandwich assay was able to detect BTV serotypes in cell culture supernatants. The use of anti-rVP7 antiserum as the detection antibody avoids the tedious and expensive purification of BTV core particles.

  20. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  1. Open versus closed sandwich wound dressing method in burn ...

    African Journals Online (AJOL)

    Methods: A retrospective study was conducted on 170 children under 12years admitted to the Pediatric surgical/female burn ward between the months of June 2006 to March 2007. A comparison was made between the open and closed sandwich method of burn wound dressing. The sandwich method entailed using 17 by ...

  2. Direct ELISA.

    Science.gov (United States)

    Lin, Alice V

    2015-01-01

    First described by Engvall and Perlmann, the enzyme-linked immunosorbent assay (ELISA) is a rapid and sensitive method for detection and quantitation of an antigen using an enzyme-labeled antibody. Besides routine laboratory usage, ELISA has been utilized in medical field and food industry as diagnostic and quality control tools. Traditionally performed in 96-well or 384-well polystyrene plates, the technology has expanded to other platforms with increase in automation. Depending on the antigen epitope and availability of specific antibody, there are variations in ELISA setup. The four basic formats are direct, indirect, sandwich, and competitive ELISAs. Direct ELISA is the simplest format requiring an antigen and an enzyme-conjugated antibody specific to the antigen. This chapter describes the individual steps for detection of a plate-bound antigen using a horseradish peroxidase (HRP)-conjugated antibody and luminol-based enhanced chemiluminescence (ECL) substrate. The methodological approach to optimize the assay by chessboard titration is also provided.

  3. One-step antibody immobilization-based rapid and highly-sensitive sandwich ELISA procedure for potential in vitro diagnostics

    Science.gov (United States)

    Vashist, Sandeep Kumar; Marion Schneider, E.; Lam, Edmond; Hrapovic, Sabahudin; Luong, John H. T.

    2014-01-01

    An improved enzyme-linked immunosorbent (ELISA) assay using one-step antibody immobilization has been developed for the detection of human fetuin A (HFA), a specific biomarker for atherosclerosis and hepatocellular carcinoma. The anti-HFA formed a stable complex with 3-aminopropyltriethoxysilane (APTES) by ionic and hydrophobic interactions. The complex adsorbed on microtiter plates exhibited a detection range of 4.9 pg mL−1 to 20 ng mL−1 HFA, with a limit of detection of 7 pg mL−1. Furthermore, an analytical sensitivity of 10 pg mL−1 was achieved, representing a 51-fold increase in sensitivity over the commercial sandwich ELISA kit. The results obtained for HFA spiked in diluted human whole blood and plasma showed the same precision as the commercial kit. When stored at 4°C in 0.1 M phosphate-buffered saline (PBS, pH 7.4), the anti-HFA bound microtiter plates displayed no significant decrease in their functional activity after two months. The new ELISA procedure was extended for the detection of C-reactive protein, human albumin and human lipocalin-2 with excellent analytical performance. PMID:24638258

  4. Development and validation of a sandwich ELISA for the determination of potentially allergenic sesame (Sesamum indicum) in food.

    Science.gov (United States)

    Redl, Gerda; Husain, Fatima T; Bretbacher, Ines E; Nemes, Albert; Cichna-Markl, Margit

    2010-10-01

    This paper presents a sandwich enzyme-linked immunosorbent assay (ELISA) that allows the determination of traces of sesame in food. Chicken anti-sesame antibodies, used as coating antibodies, and rabbit anti-sesame antibodies, used as secondary antibodies, were prepared by immunization with a protein extract of white, peeled sesame. The ELISA did not show any cross-reactivity with 19 food ingredients commonly found in sesame-containing foodstuffs such as seeds, nuts, and cereals. In whole grain bread, crisp toast, and snacks, the limit of detection (S/N = 3) was 0.5, 0.5, and 0.3 μg sesame protein/g, and the limit of quantification (S/N = 10) was 0.6, 0.8, and 1.4 μg sesame protein/g, respectively. The analysis of blank food matrices (whole grain bread, white bread, crisp toast, and snacks) spiked with sesame protein at four spike levels generally resulted in mean recoveries from 72% to 145%. In the case of spiking blank food matrices with sesame seeds, the ELISA proved to be more accurate for whole wheat cookies than for whole wheat bread.

  5. Sandwich enzyme-linked immunosorbent assay (ELISA) for detection of cashew nut in foods.

    Science.gov (United States)

    Gaskin, Ferdelie E; Taylor, Steve L

    2011-01-01

    The presence of undeclared cashew can pose a health risk to cashew-allergic consumers. The food industry has the responsibility to declare the presence of cashews on packaged foods even when trace residues are or might be present. The objective of this study was to develop a rapid, sensitive, and specific enzyme-linked immunosorbent assay (ELISA) for the detection of cashew residues. Raw and roasted cashews were defatted and used separately to immunize sheep, goats, and rabbits. The cashew ELISA was developed using sheep and rabbit polyclonal anti-roasted cashew sera as capture and detector reagents, respectively, with visualization through an alkaline phosphatase-mediated substrate reaction. The cashew ELISA was shown to have a limit of quantification of 1 ppm (1 μg cashew/g). The ELISA was highly specific except that substantial cross-reactivity was noted with pistachio and a lesser degree of cross-reactivity was noted with hazelnut. The performance of the ELISA was assessed by manufacturing cookies, ice cream, and milk chocolate with added known amounts (0 to 1000 ppm) of cashew. The mean percent recoveries for ice cream, cookies, and milk chocolate were 118%± 2.9%, 84.3%± 4.0%, and 104%± 3.0%, respectively. In a limited retail survey, 4/5 retail samples with cashew declared on ingredient labels tested positive for cashew compared to 5/36 samples of foods with precautionary labels indicating the possible presence of one or more tree nuts and 0/18 samples without cashew declared on the label in any manner. The cashew ELISA can be used to detect undeclared cashew residue in foods and as a potential tool for the food industry to assess the effectiveness of allergen control strategies and to guarantee compliance with food labeling regulatory requirements. © 2011 Institute of Food Technologists®

  6. A sandwich ELISA for porcine alpha-1acid glycoprotein (pAGP, ORM-1) and further demonstration of its use to evaluate growth potential in newborn pigs

    Science.gov (United States)

    A simple, reproducible sandwich ELISA was developed to measure porcine alpha-1 acid glycoprotein (pAGP, ORM-1) in pig plasma. Pig AGP isolated from serum was purchased and a polyclonal antisera was prepared in rabbits using the whole pAGP molecule as immunogen. The antiserum was affinity-purified...

  7. Production of mono- and polyclonal antibodies to Citrus leprosis virus C2 and their application in triple antibody sandwich ELISA and immunocapture RT-PCR diagnostic assays.

    Science.gov (United States)

    Choudhary, Nandlal; Roy, Avijit; Leon, M G; Wei, G; Nakhla, M K; Levy, L; Brlansky, R H

    2017-05-01

    The newly discovered Citrus leprosis virus cytoplasmic type 2 (CiLV-C2) is one of the causal virus of citrus leprosis disease complex; which leads to substantial loss of citrus production in the states of Meta and Casanare of Colombia. Specific and sensitive detection methods are needed to monitor the dissemination of CiLV-C2 in Colombia, and to prevent introduction of CiLV-C2 to other citrus growing countries. Toward this end, putative coat protein gene (CPG) of CiLV-C2 was amplified from CiLV-C2 infected citrus tissues. The CPG was cloned, expressed and purified a recombinant coat protein of ∼31kDa which used to generate monoclonal antibodies and polyclonal antisera. Four monoclonal antibodies and two polyclonal antisera were selected as being specific following Western blotting. The monoclonal antibody MAb E5 and polyclonal antiserum PAb UF715 were selected testing with an extract of CiLV-C2 infected leaves using triple antibody sandwich enzyme-linked immunosorbent assay (TAS-ELISA). In addition, an immunocapture RT-PCR was standardized using MAb E5 for specific and sensitive detection of CiLV-C2. The standardized TAS-ELISA and IC-RT-PCR were able to detect CiLV-C2 in the extracts of symptomatic citrus leprosis tissues up to the dilutions of 1:160 and 1:2580, respectively. Result demonstrated that CiLV-C2 is present in citrus orchards in Meta and Casanare citrus growing areas of Colombia. TAS-ELISA could be used for routine detection of CiLV-C2, epidemiological studies, and for border inspections for quarantine purposes. IC-RT-PCR could be valuable for CiLV-C2 validation and viral genome analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Detection of histidine rich protein & lactate dehydrogenase of Plasmodium falciparum in malaria patients by sandwich ELISA using in-house reagents

    OpenAIRE

    Verma, Priyanka; Biswas, Sukla; Mohan, Teena; Ali, Shakir; Rao, D.N.

    2013-01-01

    Background & objectives: Despite major control efforts, malaria remains a major public health problem that still causes high mortality rate worldwide especially in Africa and Asia. Accurate and confirmatory diagnosis before treatment initiation is the only way to control the disease. The present study was undertaken to develop reagents using sandwich ELISA for simultaneous detection of PfHRP2 (Plasmodium falciparum histidine rich protein) and PfLDH (P. falciparum lactate dehydrogenase) antige...

  9. Quantitative Detection of the Foot-And-Mouth Disease Virus Serotype O 146S Antigen for Vaccine Production Using a Double-Antibody Sandwich ELISA and Nonlinear Standard Curves

    Science.gov (United States)

    Feng, Xia; Ma, Jun-Wu; Sun, Shi-Qi; Guo, Hui-Chen; Yang, Ya-Min; Jin, Ye; Zhou, Guang-Qing; He, Ji-Jun; Guo, Jian-Hong; Qi, Shu-yun; Lin, Mi; Cai, Hu; Liu, Xiang-Tao

    2016-01-01

    The efficacy of an inactivated foot-and-mouth disease (FMD) vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV) particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG) analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA) is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS) ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01). In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings. PMID:26930597

  10. Quantitative Detection of the Foot-And-Mouth Disease Virus Serotype O 146S Antigen for Vaccine Production Using a Double-Antibody Sandwich ELISA and Nonlinear Standard Curves.

    Directory of Open Access Journals (Sweden)

    Xia Feng

    Full Text Available The efficacy of an inactivated foot-and-mouth disease (FMD vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01. In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings.

  11. Devices, systems, and methods for conducting sandwich assays using sedimentation

    Science.gov (United States)

    Schaff, Ulrich Y; Sommer, Gregory J; Singh, Anup K; Hatch, Anson V

    2015-02-03

    Embodiments of the present invention are directed toward devices, systems, and method for conducting sandwich assays using sedimentation. In one example, a method includes generating complexes on a plurality of beads in a fluid sample, individual ones of the complexes comprising a capture agent, a target analyte, and a labeling agent. The plurality of beads including the complexes may be transported through a density media, wherein the density media has a density lower than a density of the beads and higher than a density of the fluid sample, and wherein the transporting occurs, at least in part, by sedimentation. Signal may be detected from the labeling agents of the complexes.

  12. Optimisation of sandwich ELISA based on monoclonal antibodies for the specific measurement of pregnancy-associated plasma protein (PAPP-A) in acute coronary syndrome

    DEFF Research Database (Denmark)

    Rossen, Marie; Iversen, Kasper; Teisner, Ane

    2007-01-01

    on sera from patients with ACS. DESIGN AND METHODS: Candidate monoclonal antibodies (Mab) were identified by immunohistochemistry, Western blot and the absence of positive signals (ELISA) with normal, non-pregnant serum as antigen source. The ELISA technology was standardized against the original PAPP...

  13. Detection of the Peanut Allergens Ara h 2 and Ara h 6 in Human Breast Milk: Development of 2 Sensitive and Specific Sandwich ELISA Assays.

    Science.gov (United States)

    Schocker, Frauke; Scharf, Alexandra; Kull, Skadi; Jappe, Uta

    2017-01-01

    Little is known about breast milk as a vehicle for tolerance development or sensitization to peanuts very early in life. Thus, well-characterized and highly sensitive detection systems for the reliable determination of peanut allergens in breast milk are mandatory. For the quantification of the marker allergens Ara h 2 and Ara h 6 in the low nanogram per milliliter range in breast milk samples of a German cohort, sensitive and highly specific sandwich ELISAs were optimized and validated. The Ara h 2 ELISA revealed a limit of detection (LOD) of 1.3 ng Ara h 2/mL and a quantification range of 2.3-250 ng/mL, the Ara h 6 ELISA showed an LOD of 0.7 ng/mL and a working range of 1.1-14.4 ng/mL. The assays showed no relevant cross-reactivity against other potentially cross-reactive legume, seed, and tree nut extracts (h 1 in the Ara h 2 ELISA h 2 was detectable in breast milk samples from 14/40 (35%) of the participants in concentrations from 2.3 to 184 ng/mL, Ara h 6 appeared in 9/40 (22.5%) of the lactating mothers between 1.1 and 9.7 ng/mL, and 1 highly positive sample with 79 ng/mL. Both allergens appeared at the same time points, but Ara h 6 in lower concentrations than Ara h 2. Sensitive and specific diagnostic tools for the determination of Ara h 2 and Ara h 6 in human breast milk were established. The kinetics of secreted Ara h 2 and Ara h 6 seem to be similar but with a difference in concentration. Follow-up investigations on their tolerogenic or sensitizing properties in breast milk become now accessible. © 2017 S. Karger AG, Basel.

  14. Sandwich Structured Composites for Aeronautics: Methods of Manufacturing Affecting Some Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Aneta Krzyżak

    2016-01-01

    Full Text Available Sandwich panels are composites which consist of two thin laminate outer skins and lightweight (e.g., honeycomb thick core structure. Owing to the core structure, such composites are distinguished by stiffness. Despite the thickness of the core, sandwich composites are light and have a relatively high flexural strength. These composites have a spatial structure, which affects good thermal insulator properties. Sandwich panels are used in aeronautics, road vehicles, ships, and civil engineering. The mechanical properties of these composites are directly dependent on the properties of sandwich components and method of manufacturing. The paper presents some aspects of technology and its influence on mechanical properties of sandwich structure polymer composites. The sandwiches described in the paper were made by three different methods: hand lay-up, press method, and autoclave use. The samples of sandwiches were tested for failure caused by impact load. Sandwiches prepared in the same way were used for structural analysis of adhesive layer between panels and core. The results of research showed that the method of manufacturing, more precisely the pressure while forming sandwich panels, influences some mechanical properties of sandwich structured polymer composites such as flexural strength, impact strength, and compressive strength.

  15. Detection of histidine rich protein & lactate dehydrogenase of Plasmodium falciparum in malaria patients by sandwich ELISA using in-house reagents.

    Science.gov (United States)

    Verma, Priyanka; Biswas, Sukla; Mohan, Teena; Ali, Shakir; Rao, D N

    2013-12-01

    Despite major control efforts, malaria remains a major public health problem that still causes high mortality rate worldwide especially in Africa and Asia. Accurate and confirmatory diagnosis before treatment initiation is the only way to control the disease. The present study was undertaken to develop reagents using sandwich ELISA for simultaneous detection of PfHRP2 (Plasmodium falciparum histidine rich protein) and PfLDH (P. falciparum lactate dehydrogenase) antigens in the proven malaria cases. The antibodies were raised against two epitopes of PfHRP2 protein and three unique and unexplored epitopes of PfLDH protein. These antibodies were able to detect PfHRP2 and PfLDH antigens in culture supernatant and parasitized RBC lysate of P. falciparum, respectively up to 50 parasites/μl. The in-house reagents were tested in 200 P. falciparum positive patients residing in Baghpat district of Uttar Pradesh in northern India. Microsphere (PLGA) with CpG ODN were used to generate high titre and high affinity antibodies against selected peptides of PfHRP-2 and pLDH antigen in mice and rabbit. The peptide specific peak titre varied from 12,800 - 102,400 with an affinity ranging 0.73 - 3.0 mM. The indigenously developed reagents are able to detect PfHRP2 and PfLDH antigens as low as 75 parasites/μl of blood with a very high sensitivity (96-100%) and specificity (100%). The study highlight the identification of unique epitopes of PfHRP2 and PfLDH, and the generated antibodies against these antigens were used for quantitative estimation of these two antigens using sandwich ELISA. No corresreactivity with P. vivax infected patients was observed with the sera.

  16. Entamoeba histolytica: detection of coproantigens by purified antibody in the capture sandwich ELISA Entamoeba histolytica: detecção de coproantígenos por ELISA de captura utilizando anticorpo purificado

    Directory of Open Access Journals (Sweden)

    Haidee Urdaneta

    1994-12-01

    Full Text Available A sensitive and specific Capture Sandwich ELISA (CSE was developed using polyclonal purified rabbit antibodies against three different axenic strains of Entamoeba histolytica: CSP from Brazil and HM1 - IMSS from Mexico, for the detection of coproantigens in fecal samples. Immunoglobulin G (IgG againstis E. histolytica was isolated from rabbits immunized with throphozoites whole extract in two stages: affinity chromatography in a column containing E. histolytica antigens bound to Sepharose 4B was followed by another chromatography in Sepharose antibodies 4B-Protein A. A Capture Sandwich ELISA using purified antibodies was able to detect 70ng of amebae protein, showing a sensitivity of 93% and specificity of 94%. The combination of microscopic examination and CSE gave a concordance and discordance of 93.25% and 6.75%, respectively. It was concluded that CSE is highly specific for the detection of coproantigens of E. histolytica in feces of infected patients, is quicker to perform, easier and more sensitive than microscopic examination.Foi desenvolvido um teste de ELISA de Captura usando anticorpos policlonais purificados obtidos em coelhos contra três diferentes cepas axênicas de Entamoeba histolytica (ICB-CSP and ICB-462 do Brasil e HM1 do México para detecção de coproantígenos em amostras de fezes de indivíduos: a sintomáticos, b assintomáticos, c com outros parasitos intestinais, e d sadios. Imunoglobulina G (IgG contra E. histolytica foi isolada de imune soro de coelho, em duas etapas: cromatografia de afinidade em uma coluna contendo antígenos de E. histolytica unidos à Sepharose 4B, seguido por outra cromatografía em Sepharose 4B Proteína A. O teste de ELISA usando anticorpos purificados, foi capaz de detectar até um só trofozoíto por lâmina ou 70 ng de proteína de ameba por orifício, apresentando uma sensibilidade de 93% e uma especificidade de 94%. A combinação do exame microscópico com o método de ELISA de Captura

  17. Development of a double sandwich fluorescent ELISA to detect rattlesnake venom in biological samples from horses with a clinical diagnosis of rattlesnake bite.

    Science.gov (United States)

    Gilliam, Lyndi L; Ownby, Charlotte L; McFarlane, Dianne; Canida, Amy; Holbrook, Todd C; Payton, Mark E; Krehbiel, Clinton R

    2013-10-01

    Rattlesnake bites in horses are not uncommon and the clinical outcomes are widely variable. Treatment of horses with anti-venom is often cost prohibitive and could have negative consequences; therefore, the development of a quantitative test to determine if anti-venom therapy is indicated would be valuable. The objective of this study was to develop an ELISA to detect rattlesnake venom in biological samples from clinically bitten horses. Nineteen horses were enrolled in the study. Urine was available from 19 horses and bite site samples were available from 9 horses. A double sandwich fluorescent ELISA was developed and venom was detected in 5 of 9 bite site samples and 12 of 19 urine samples. In order to determine if this assay is useful as a guide for treatment, a correlation between venom concentration and clinical outcome needs to be established. For this, first peak venom concentration needs to be determined. More frequent, consistent sample collection will be required to define a venom elimination pattern in horses and determine the ideal sample collection time to best estimate the maximum venom dose. This report describes development of an assay with the ability to detect rattlesnake venom in the urine and at the bite site of horses with a clinical diagnosis of rattlesnake bite. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Standard Test Method for Laboratory Aging of Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the resistance of sandwich panels to severe exposure conditions as measured by the change in selected properties of the material after exposure. The exposure cycle to which the specimen is subjected is an arbitrary test having no correlation with natural weathering conditions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Screening methods in alveolar echinococcosis: a follow-up study comparing Emc- and Emf-ELISA with Em2plus-ELISA and ultrasonography.

    Science.gov (United States)

    Hänle, M M; Banzhaf, H-M; Forsbach-Birk, V; Kirch, A; Akinli, A S; Mason, R A; Reuter, S; Kratzer, W

    2009-01-01

    The purpose of the present study was to identify Echinococcus multilocularis infection in follow-up of 95 subjects initially seropostive by Emc-ELISA or Emf-ELISA antibody assays and to compare the utility of these assays with specific Em2plus-ELISA and ultrasound screening for E. multilocularis infection. At follow-up seven subjects were seropositive with both methods, while three were seropositive only with Emc-ELISA and 11 only with Emf-ELISA. All subjects were seronegative with Em2plus-ELISA. There were no manifestations of E. multilocularis infestation by ultrasonographic screening. Seropositivity on Emc-ELISA and Emf-ELISA screening tests does not appear to correlate with manifest alveolar echinococcosis identified by ultrasound. A recommendation for further follow-up of subjects found to be seropositive with Emc-ELISA and Emf-ELISA but with no sonographic evidence of disease is not justified at this time.

  20. A sandwich ELISA for porcine alpha-1 acid glycoprotein (pAGP, ORM-1) and further demonstration of its use to evaluate growth potential in newborn pigs.

    Science.gov (United States)

    Caperna, T J; Shannon, A E; Stoll, M; Kahl, S; Blomberg, L A; Vallet, J L; Ramsay, T G

    2017-07-01

    A simple, reproducible sandwich, ELISA was developed to measure porcine alpha-1 acid glycoprotein (pAGP, ORM-1) in pig plasma. Porcine AGP isolated from serum was purchased and a polyclonal antisera was prepared in rabbits using the whole pAGP molecule as immunogen. The antiserum was affinity purified, and a portion of the purified antibody fraction was labeled with horseradish peroxidase. Porcine AGP protein was used as a standard, whereas commercially available buffers and reagents were utilized throughout the assay. The assay was specific for pAGP, had a lower limit of detection of 3.2 ng/mL, and could be used to quantify pAGP in plasma or serum. Using this ELISA, we corroborated our previous findings obtained by RID assay, which demonstrated that the AGP concentration in newborn piglets is negatively associated with preweaning growth rate. The current data were obtained using piglets from a different geographical location and genetic background and showed that elevated AGP at birth was associated with reduced preweaning growth rate (P < 0.001, r = 0.433, n = 19 litters). In addition, litters with a greater average AGP at birth were at a growth disadvantage compared with litters with reduced average AGP plasma concentrations (P < 0.001, r = 0.708, n = 19 litters). Litter average plasma AGP was a better predictor of litter preweaning growth rate than average litter birth weight. The data represent further support for using perinatal AGP concentrations as a tool to identify potential slower growing pigs and as a plasma biomarker for predicting litter growth rate. Published by Elsevier Inc.

  1. Research overview of design method of super light multi-hole class- honeycomb sandwich structure materials

    Directory of Open Access Journals (Sweden)

    Xiang LI

    Full Text Available With the sandwich structure materials' application and promotion in the field of engineering continuously, existing sandwich structure material gradually cannot meet the design requirements. It is very urgent to develop new sandwich structure materials of high efficiency, energy saving and easy to process. The project puts forward and constructs a new kind of class-honeycomb sandwich structure material combined with important application backgrounds that super light and high strength metal sandwich structure materials are applied into the high weight and high energy consumption equipments of automobile, aerospace and machinery and so on. This research involve: mechanical properties equivalent method for the class-honeycomb sandwich structure and its core; Strength, stiffness and inherent frequency characteristic and failure criterions of the class-honeycomb sandwich structure; based on the failure criterions constructing the multiple-constraint models of the class-honeycomb sandwich structure. The research tries to put forward a new method for innovative design of lightweight material and structure and new ideas of lightweight technology research in theory and practice.

  2. Methods in virus diagnostics: from ELISA to next generation sequencing.

    Science.gov (United States)

    Boonham, Neil; Kreuze, Jan; Winter, Stephan; van der Vlugt, René; Bergervoet, Jan; Tomlinson, Jenny; Mumford, Rick

    2014-06-24

    Despite the seemingly continuous development of newer and ever more elaborate methods for detecting and identifying viruses, very few of these new methods get adopted for routine use in testing laboratories, often despite the many and varied claimed advantages they possess. To understand why the rate of uptake of new technologies is so low, requires a strong understanding of what makes a good routine diagnostic tool to begin. This can be done by looking at the two most successfully established plant virus detection methods: enzyme-linked immunosorbant assay (ELISA) and more recently introduced real-time polymerase chain reaction (PCR). By examining the characteristics of this pair of technologies, it becomes clear that they share many benefits, such as an industry standard format and high levels of repeatability and reproducibility. These combine to make methods that are accessible to testing labs, which are easy to establish and robust in their use, even with new and inexperienced users. Hence, to ensure the establishment of new techniques it is necessary to not only provide benefits not found with ELISA or real-time PCR, but also to provide a platform that is easy to establish and use. In plant virus diagnostics, recent developments can be clustered into three core areas: (1) techniques that can be performed in the field or resource poor locations (e.g., loop-mediated isothermal amplification LAMP); (2) multiplex methods that are able to detect many viruses in a single test (e.g., Luminex bead arrays); and (3) methods suited to virus discovery (e.g., next generation sequencing, NGS). Field based methods are not new, with Lateral Flow Devices (LFDs) for the detection being available for a number of years now. However, the widespread uptake of this technology remains poor. LAMP does offer significant advantages over LFDs, in terms of sensitivity and generic application, but still faces challenges in terms of establishment. It is likely that the main barrier to the

  3. Validation of a digital photographic method for assessment of dietary quality of school lunch sandwiches brought from home

    DEFF Research Database (Denmark)

    Sabinsky, Marianne S; Toft, Ulla; Andersen, Klaus Kaae

    2013-01-01

    intake from school lunch sandwiches brought from home among children aged 7-13 years. DESIGN: School lunch sandwiches (n=191) were prepared to represent randomly selected school lunch sandwiches from a large database. All components were weighed to provide an objective measure of the composition...... and the Meal IQ obtained from the digital images were validated against the objective weighed foods of the school lunch sandwiches. To determine interrater reliability, the digital images were evaluated by a second image analyst. RESULTS: Correlation coefficients between the DPM and the weighed foods ranged...... and reliable method for assessing the dietary quality of school lunch sandwiches brought from home....

  4. A New Method of Impregnating PEl Sheets for the In-Situ Foaming of Sandwiches

    NARCIS (Netherlands)

    Provo Kluit, P.W.C.

    1998-01-01

    A new method is described to make foamable films for the production of in-situ foamed sandwiches. The method consists of placing a polymer film in a bath with a swelling agent and, when equilibrium swelling has been reached, placing the film in a bath with a second liquid. If the liquids are

  5. Comparison of ELISA and TLC Methods for the Morphine Detection in Urine of Drug Abusers

    Directory of Open Access Journals (Sweden)

    Alireza Timcheh-Hariri

    2016-04-01

    Full Text Available Background: The current study was conducted to compare ELISA with thin layer chromatography (TLC methods for diagnosis of morphine in the urine. Methods: Positive urine samples for morphine confirmed by immunochromatographic strips were collected from the Imam Reza Toxicology Laboratory, Mashhad University of Medical Sciences, Mashhad, Iran in 2012 for the current study. Then, the collated urine samples (70 were analyzed by both ELISA and TLC methods. Results: On analyzing samples by TLC, 57 out of 70 (81.4% revealed morphine spot, whereas by ELISA method all samples were positive. The difference was statisticaly significant (P=0.0001. Both immunoassays had the same 100% positive results. The possible 18.6% false positive results might be due to drug interactions. TLC is more specific but time-consuming and less sensitive than ELISA is. However, TLC is an old method but more reliable than ELISA. Conclusion: Contrary to the claim that commercially available ELISA kits have a high specificity for detection of morphine derivatives; it seems that false positive results may occur. It is thus recommended that all positive results obtained from ELISA be checked by a cheap widely available confirmation test of TLC or ideally by a quantitative technique such as GC-Mass spectroscopy, particularly for legal purposes.

  6. Bepaling van het gehalte aan soja in vleesprodukten m.b.v. ELISA-methode

    OpenAIRE

    Visser-Meijer, M.A.; Buizer, F.G.

    1983-01-01

    Het gehalte soja-eiwit is bepaald in 3 monsters vleesprodukt met bekende hoeveelheid soja en vervolgens in 7 monsters vleesprodukt met onbekende hoeveelheid soja. De bepaling geschiedde met behulp van een ELISA methode.

  7. Sound transmission analysis of partially treated MR fluid-based sandwich panels using finite element method

    Science.gov (United States)

    Hemmatian, M.; Sedaghati, R.

    2017-04-01

    This study aims at developing a finite element model to predict the sound transmission loss (STL) of a multilayer panel partially treated with a Magnetorheological (MR) fluid core layer. MR fluids are smart materials with promising controllable rheological characteristics in which the application of an external magnetic field instantly changes their rheological properties. Partial treatment of sandwich panels with MR fluid core layer provides an opportunity to change stiffness and damping of the structure without significantly increasing the mass. The STL of a finite sandwich panel partially treated with MR fluid is modeled using the finite element (FE) method. Circular sandwich panels with clamped boundary condition and elastic face sheets in which the core layer is segmented circumferentially is considered. The MR fluid core layer is considered as a viscoelastic material with complex shear modulus with the magnetic field and frequency dependent storage and loss moduli. Neglecting the effect of the panel's vibration on the pressure forcing function, the work done by the acoustic pressure is expressed as a function of the blocked pressure in order to calculate the force vector in the equation of the motion of the panel. The governing finite element equation of motion of the MR sandwich panel is then developed to predict the transverse vibration of the panel which can then be utilized to obtain the radiated sound using Green's function. The developed model is used to conduct a systematic parametric study on the effect of different locations of MR fluid treatment on the natural frequencies and the STL.

  8. Evaluation of a Commercial Sandwich Enzyme-Linked Immunosorbent Assay for the Quantification of Beta-Casomorphin 7 in Yogurt Using Solid-Phase Extraction Coupled to Liquid Chromatography-Tandem Mass Spectrometry as the "Gold Standard" Method.

    Science.gov (United States)

    Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann

    2017-08-01

    This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linkedimmunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.

  9. Development of an ELISA Method Detecting Strobilurin Fungicide through the Immune Magnetic Beads Collecting Samples

    OpenAIRE

    Xun C. Huang; Jie Zhu; Xian J. Dai

    2015-01-01

    Trifloxystrobin, one of the strobilurin fungicides, is active as inhibitor of low toxicity and easy degradation against a wide range of fungal plant pathogens. In the experiment, Hydroxy from magnetic microsphere and amino of anti-Trifloxystrobin antibody could condensate to form Immune Magnetic Beads (IMB), which could specially capture trifloxystrobin in the food matrix and rapidly separated it through the magnetic field. An ELISA method (IMB-ELISA) was developed to detect the captured fung...

  10. An ELISA Lab-on-a-Chip (ELISA-LOC).

    Science.gov (United States)

    Rasooly, Avraham; Bruck, Hugh A; Kostov, Yordan

    2013-01-01

    Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.

  11. Detection of pyrogenicity on medical grade polymer materials using rabbit pyrogen, LAL and ELISA method.

    Science.gov (United States)

    Mohanan, P V; Banerjee, Siddharth; Geetha, C S

    2011-07-15

    The objective of the study is to detect the pyrogenicity of five medical grade gelatinous polymer materials, intended for the manufacturing of capsule for pharmaceutical applications, by an indigenously developed ELISA, LAL and rabbit pyrogen assays. The ELISA methodology includes the incubation of the sample extract with blood from a healthy donor at 37°C. Any pyrogen present in the extract induces the IL-1β which can be determined by ELISA. The rabbit pyrogen and LAL assays were performed as per standards. The result of the ELISA method indicated that all the materials extract induced high level of IL-1β as a marker for pyrogenicity. The rise in temperature of rabbit pyrogen was above 0.5°C in all materials extract. LAL assay induced an endotoxin level above 0.5EU. All the five polymer materials were found pyrogenic in all the assays. The ELISA method is very sensitive because the lowest limit of detection was 10pg/ml endotoxin. Hence it can be concluded that the ELISA method will be an added advantage for the quality control release of a batch of medical products and improving the existing methodologies in the context of reduction and replacement in the use of animal models. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Sensitivity improvement of a sandwich-type ELISA immunosensor for the detection of different prostate-specific antigen isoforms in human serum using electrochemical impedance spectroscopy and an ordered and hierarchically organized interfacial supramolecular architecture.

    Science.gov (United States)

    Gutiérrez-Zúñiga, Gabriela Guadalupe; Hernández-López, José Luis

    2016-01-01

    A gold millielectrode (GME) functionalized with a mixed (16-MHA + EG3SH) self-assembled monolayer (SAM) was used to fabricate an indirect enzyme-linked immunosorbent assay (ELISA) immunosensor for the sensitive detection of prostate-specific antigen (PSA), a prostate cancer (PCa) biomarker, in human serum samples. To address and minimize the issue of non-specific protein adsorption, an organic matrix (amine-PEG3-biotin/avidin) was assembled on the previously functionalized electrode surface to build up an ordered and hierarchically organized interfacial supramolecular architecture: Au/16-MHA/EG3SH/amine-PEG3-biotin/avidin. The electrode was then exposed to serum samples at different concentrations of a sandwich-type immunocomplex molecule ((Btn)Ab-AgPSA-(HRP)Ab), and its interfacial properties were characterized using electrochemical impedance spectroscopy (EIS). Calibration curves for polarization resistance (RP) and capacitance (1/C) vs. total and free PSA concentrations were obtained and their analytical quality parameters were determined. This approach was compared with results obtained from a commercially available ELISA immunosensor. The results obtained in this work showed that the proposed immunosensor can be successfully applied to analyze serum samples of patients representative of the Mexican population. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. [Using HTS-ELISA method to make anti-aflatoxin M1 monoclonal antibody].

    Science.gov (United States)

    Pei, Shichun; He, Na; Zhang, Lijun; Lu, Mason

    2010-10-01

    To prepare high-affinity anti-aflatoxin M1 monoclonal antibodies by High Throughput Screening ELISA (HTS-ELISA) METHODS: Balb/C mice were immunized by aflatoxin M1-bovine serum albumin conjugate, and screen secret anti-aflatoxin M1 monoclonal antibody hybridoma by HTS-ELISA. The antibody was characterized. Fourteen hybridoma cell lines which could secret high activity anti-aflatoxin M1 monoclonal antibodies were obtained. The affinity of the purified monoclonal antibody was 5.5 x 10(-10) mol/L. The cross-reactivity of the monoclonal antibody clone against aflatoxin M1, aflatoxin M2, aflatoxin B1, aflatoxin B2, aflatoxin G1, aflatoxin G2, deoxynivalenol and BSA was 100%, 4.5%, 21.5%, 1.0%, 16.6%, 1.0%, 0%, 0%, respectively. The sensitivity of the anti-AFM1 monoclonal antibody binding to aflatoxin M1 was 0.01 microg/L and the linear range for developed indirect competitive ELISA was 0.1 - 10 microg/L aflatoxin M1. The binding inhibition IC50 of the anti-aflatoxin M1 monoclonal antibody was 0.82 microg/L. Assays of milk samples mixed with AFM1 ranging in concentration from 0.25 to 5.0 microg/L gave mean indirect competitive ELISA recovery of 60.3% - 152.8%. HTS-ELISA can be used for the preparation of the high-affinity anti-aflatoxin M1 monoclonal antibodies. The anti-aflatoxin M1 monoclonal antibody could be provided as the high quality material in the system of aflatoxin M1 immune detection.

  14. Comparison of the NIDS® rapid assay with ELISA methods in immunogenicity testing of two biotherapeutics.

    Science.gov (United States)

    Pan, Jing; Small, Thomas; Qin, Dujie; Li, Shawn; Wang, Li; Chen, Dave; Pauley, Cindy; Verch, Thorsten; Kaplanski, Catherine; Bakhtiar, Ray; Vallejo, Yli Remo; Yin, Ray

    2011-01-01

    Rapid lateral flow immunogenicity assays for the detection of anti-drug antibodies (ADAs) to two biotherapeutic antibodies, an anti-HER2 antibody and an anti-TNF-α antibody, were developed using ANP Technologies, Inc.'s proprietary Nano-Intelligent Detection System (NIDS®) and compared to their ELISA counterparts. Biotin and hapten-labeled drugs are incubated with the patient serum sample to allow ADA to form a bridge complex with each drug conjugate. The reaction mixture is then added to a test strip with an anti-hapten capture zone which captures the mixed bridge complex. The bridge-complexed biotinylated drug then reacts with streptavidin-labeled gold particles in situ. The signal developed at the capture zone, which is directly proportional to ADA in the sample, is then quantitatively measured with a handheld reader. The counterpart ELISAs were run using the same reagents. Dose-response, specificity/free drug depletion, and screening cut-point assays were performed using both methods. The rapid assays' performance compare very closely to their ELISA counterparts'. Both types of assays identified the same positive samples in screening a limited population of 50 normal serum samples for the anti-HER2 antibody. In the case of anti-TNF-α, both assays identified the same positive samples out of 50 normal and 20 rheumatoid arthritis patient serum samples but differed in the assessment of two others. The rapid assay correctly identified as negative an ELISA false positive sample, and correctly tested as positive an ELISA false negative sample. Positive results were verified with a specificity/free drug depletion assay. The NIDS® rapid immunogenicity assay offers distinct advantages over current methods in simplicity, low cost, and short time to result. More importantly, the method requires no sample dilution and no washing steps which can perturb fragile complexes formed by low-affinity ADAs. Thus, the assay can potentially detect ADAs with various affinities

  15. Shape and Stress Sensing of Multilayered Composite and Sandwich Structures Using an Inverse Finite Element Method

    Science.gov (United States)

    Cerracchio, Priscilla; Gherlone, Marco; Di Sciuva, Marco; Tessler, Alexander

    2013-01-01

    The marked increase in the use of composite and sandwich material systems in aerospace, civil, and marine structures leads to the need for integrated Structural Health Management systems. A key capability to enable such systems is the real-time reconstruction of structural deformations, stresses, and failure criteria that are inferred from in-situ, discrete-location strain measurements. This technology is commonly referred to as shape- and stress-sensing. Presented herein is a computationally efficient shape- and stress-sensing methodology that is ideally suited for applications to laminated composite and sandwich structures. The new approach employs the inverse Finite Element Method (iFEM) as a general framework and the Refined Zigzag Theory (RZT) as the underlying plate theory. A three-node inverse plate finite element is formulated. The element formulation enables robust and efficient modeling of plate structures instrumented with strain sensors that have arbitrary positions. The methodology leads to a set of linear algebraic equations that are solved efficiently for the unknown nodal displacements. These displacements are then used at the finite element level to compute full-field strains, stresses, and failure criteria that are in turn used to assess structural integrity. Numerical results for multilayered, highly heterogeneous laminates demonstrate the unique capability of this new formulation for shape- and stress-sensing.

  16. An Investigation into the Application of Generalized Differential Quadrature Method to Bending Analysis of Composite Sandwich Plates

    Science.gov (United States)

    Ghassemi, Aazam; Yazdani, Mostafa; Hedayati, Mohamad

    2017-12-01

    In this work, based on the First Order Shear Deformation Theory (FSDT), an attempt is made to explore the applicability and accuracy of the Generalized Differential Quadrature Method (GDQM) for bending analysis of composite sandwich plates under static loading. Comparative studies of the bending behavior of composite sandwich plates are made between two types of boundary conditions for different cases. The effects of fiber orientation, ratio of thickness to length of the plate, the ratio of thickness of core to thickness of the face sheet are studied on the transverse displacement and moment resultants. As shown in this study, the role of the core thickness in deformation of these plates can be reversed by the stiffness of the core in comparison with sheets. The obtained graphs give very good results due to optimum design of sandwich plates. In Comparison with existing solutions, fast convergent rates and high accuracy results can be achieved by the GDQ method.

  17. Comparison of new immunofluorescence method for detection of soy protein in meat products with immunohistochemical, histochemical, and ELISA methods

    Directory of Open Access Journals (Sweden)

    Michaela Petrášová

    2014-01-01

    Full Text Available Soy proteins are commonly used in the food industry thanks to their technological properties. However, soy is, along with cow’s milk, eggs, wheat, peanuts, tree nuts, fish, crustaceans, and molluscs, responsible for around 90% of food allergies, and is also one of the foodstuffs that can cause anaphylaxis. The aim of this work was to compare the immunofluorescence method for the detection of soy protein in meat products purchased from the retail market with other microscopic methods (immunohistochemical and histochemical, with the ELISA reference method and with the confirmatory results. Within the research, 127 meat products purchased in the retail network were examined using the immunofluorescence method used for the detection of soy protein. The method was compared to Enzyme-Linked ImmunoSorbent Assay (ELISA, immunohistochemical, and histochemical methods. According to McNemar’s test, non-compliance between the immunofluorescence method and immunohistochemical method was low. In addition, a significant difference between the fluorescence method and ELISA (P P < 0.01 was found. The immunofluorescence method was also compared with confirmatory results. According to McNemar’s test, non-compliance between the immunofluorescence method and confirmatory results was low. The results showed the possibilities of this new method to detect the content of soy protein in meat products.

  18. Detection and determination of Melamine in infant formula by ELISA method

    Directory of Open Access Journals (Sweden)

    A Shakerian

    2012-05-01

    Full Text Available Thirty-six samples of infant formula with different production dates and various brands were purchased from Isfahan city during 2012. The samples were assayed for the presence and quantity of melamine by ELISA screening method. According to the results, in any infant formula melamine contamination was observed above the detection limit of the kit (10 µg/L. Therefore, it was concluded that the infant formula at Isfahan retail is not considered a health hazard from the melamine contamination point of view.

  19. Determination of aflatoxins in nuts of Tabriz confectionaries by ELISA and HPLC methods

    Directory of Open Access Journals (Sweden)

    Siahi Shadbad Mohammad Reza

    2012-06-01

    Full Text Available Purpose: Aflatoxins (AFs are a group of mycotoxins and secondary metabolites of various species of Aspergillus. There are various forms of aflatoxins including B1, B2, G1, G2, M1 and M2 types. Aflatoxins cause important health problems and have high potential effect on liver cancer. Therefore, numerous investigations have been conducted during last three decades. The aim of this work is to determine the contamination levels of nuts used by the confectionaries in Tabriz. Methods: A total of 142 samples including 35 almond , 26 walnut, 4 seeds of apricot, 6 sunflower seeds kernel, 6 sesame seed, 6 peanuts , 32 pistachio,13 hazelnuts and 14 cashews samples were collected from Tabriz confectionaries. The ELISA method was employed for the screening of total aflatoxins. Results: In 13 cases (28.1% of pistachios, 5.1% of walnuts and 7.1% of cashews contamination rate of higher than 15 ppb were observed. The HPLC method was applied for the confirmation of ELISA results. Aflatoxin B1 was the highest detected AFs. Conclusion: The overall results of the tested samples indicated that the rate of contamination of pistachios is higher than the other tested samples.

  20. Determination of aflatoxins in nuts of Tabriz confectionaries by ELISA and HPLC methods.

    Science.gov (United States)

    Siahi Shadbad, Mohammad Reza; Ansarin, Masoud; Tahavori, Ali; Ghaderi, Faranak; Nemati, Mahboob

    2012-01-01

    Aflatoxins (AFs) are a group of mycotoxins and secondary metabolites of various species of Aspergillus. There are various forms of aflatoxins including B1, B2, G1, G2, M1 and M2 types. Aflatoxins cause important health problems and have high potential effect on liver cancer. Therefore, numerous investigations have been conducted during last three decades. The aim of this work is to determine the contamination levels of nuts used by the confectionaries in Tabriz. A total of 142 samples including 35 almond , 26 walnut, 4 seeds of apricot, 6 sunflower seeds kernel, 6 sesame seed, 6 peanuts , 32 pistachio,13 hazelnuts and 14 cashews samples were collected from Tabriz confectionaries. The ELISA method was employed for the screening of total aflatoxins. In 13 cases (28.1% of pistachios, 5.1% of walnuts and 7.1% of cashews) contamination rate of higher than 15 ppb were observed. The HPLC method was applied for the confirmation of ELISA results. Aflatoxin B1 was the highest detected AFs. The overall results of the tested samples indicated that the rate of contamination of pistachios is higher than the other tested samples.

  1. Validation of a digital photographic method for assessment of dietary quality of school lunch sandwiches brought from home

    Directory of Open Access Journals (Sweden)

    Marianne S. Sabinsky

    2013-07-01

    Full Text Available Background: It is a challenge to assess children's dietary intake. The digital photographic method (DPM may be an objective method that can overcome some of these challenges. Objective: The aim of this study was to evaluate the validity and reliability of a DPM to assess the quality of dietary intake from school lunch sandwiches brought from home among children aged 7–13 years. Design: School lunch sandwiches (n=191 were prepared to represent randomly selected school lunch sandwiches from a large database. All components were weighed to provide an objective measure of the composition. The lunches were photographed using a standardised DPM. From the digital images, the dietary components were estimated by a trained image analyst using weights or household measures and the dietary quality was assessed using a validated Meal Index of Dietary Quality (Meal IQ. The dietary components and the Meal IQ obtained from the digital images were validated against the objective weighed foods of the school lunch sandwiches. To determine interrater reliability, the digital images were evaluated by a second image analyst. Results: Correlation coefficients between the DPM and the weighed foods ranged from 0.89 to 0.97. The proportion of meals classified in the same or an adjacent quartile ranged from 98% (starch to 100% (fruits, vegetables, fish, whole grain, and Meal IQ. There was no statistical difference between fish, fat, starch, whole grains, and Meal IQ using the two methods. Differences were found for fruits and vegetables; Bland–Altman analyses showed a tendency to underestimate high amounts of these variables using the DPM. For interrater reliability, kappa statistics ranged from 0.59 to 0.82 across the dietary components and Meal IQ. Conclusions: The standardised DPM is a valid and reliable method for assessing the dietary quality of school lunch sandwiches brought from home.

  2. Validation of a digital photographic method for assessment of dietary quality of school lunch sandwiches brought from home.

    Science.gov (United States)

    Sabinsky, Marianne S; Toft, Ulla; Andersen, Klaus K; Tetens, Inge

    2013-01-01

    It is a challenge to assess children's dietary intake. The digital photographic method (DPM) may be an objective method that can overcome some of these challenges. The aim of this study was to evaluate the validity and reliability of a DPM to assess the quality of dietary intake from school lunch sandwiches brought from home among children aged 7-13 years. School lunch sandwiches (n=191) were prepared to represent randomly selected school lunch sandwiches from a large database. All components were weighed to provide an objective measure of the composition. The lunches were photographed using a standardised DPM. From the digital images, the dietary components were estimated by a trained image analyst using weights or household measures and the dietary quality was assessed using a validated Meal Index of Dietary Quality (Meal IQ). The dietary components and the Meal IQ obtained from the digital images were validated against the objective weighed foods of the school lunch sandwiches. To determine interrater reliability, the digital images were evaluated by a second image analyst. Correlation coefficients between the DPM and the weighed foods ranged from 0.89 to 0.97. The proportion of meals classified in the same or an adjacent quartile ranged from 98% (starch) to 100% (fruits, vegetables, fish, whole grain, and Meal IQ). There was no statistical difference between fish, fat, starch, whole grains, and Meal IQ using the two methods. Differences were found for fruits and vegetables; Bland-Altman analyses showed a tendency to underestimate high amounts of these variables using the DPM. For interrater reliability, kappa statistics ranged from 0.59 to 0.82 across the dietary components and Meal IQ. The standardised DPM is a valid and reliable method for assessing the dietary quality of school lunch sandwiches brought from home.

  3. Development and use of specific ELISA methods for quantifying the biological activity of bevacizumab, cetuximab and trastuzumab in stability studies.

    Science.gov (United States)

    Suárez, Inmaculada; Salmerón-García, Antonio; Cabeza, José; Capitán-Vallvey, Luis Fermín; Navas, Natalia

    2016-10-01

    Bevacizumab (BVZ), cetuximab (CTX) and trastuzumab (TTZ) are monoclonal antibodies (mAbs) used worldwide for the treatment of several widespread kinds of cancer. They are marketed as medicines under their respective tradenames: Avastin(®), Erbitux(®) and Herceptin(®). The aim of this research was to develop in-house specific enzyme-linked immunosorbent assays (ELISA) to assess the long-term stability of these three mabs. These assays assess the biological functionality of the mAbs by quantifying their biological activity. For this purpose, we developed an indirect ELISA procedure whereby the specific antigens against which the mAbs are directed are used as specific "capturing" antibodies on the ELISA plates. We therefore used vascular endothelial growth factor (VEGF) in the ELISA for BVZ; human epidermal growth factor receptor (hEGFR) in the ELISA for CTX and human receptor HER2 (hHER2) in the ELISA for TTZ. After the mAbs had attached to their antigen, we used an anti-human IgG (whole molecule) peroxidase-conjugate and o-phenylenediaminedihydrochloride substrate. The reaction was stopped using sulphuric acid and absorbance was recorded at a wavelength of 450nm. The three ELISA methods were validated in terms of calibration models, range of the assay, limits of detection and quantitation, intra and interday precision and accuracy, and specificity by cross reactions. Forced degradation studies were also conducted on the medicines, providing useful information. Finally, the proposed ELISA were successfully used in a long-term stability study to quantify the remaining biological activity in medicines that had been opened and then stored under two different storage conditions, i.e. refrigerated at 4°C and frozen at -20°C. Results indicated that BVZ (Avastin(®)) is the most stable of the three in terms of its biological functionality. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Fracture Characterization of PVC Foam Core Sandwich Specimen Using the DCB-UBM Test Method

    DEFF Research Database (Denmark)

    Saseendran, Vishnu; Berggreen, Christian; Carlsson, Leif A.

    2017-01-01

    coupled with experimental validation is paramount to determine the fracture resistance of the face/core interface. In this paper, the test-rig exploiting the double cantilever beam with uneven bending moments (DCB-UBM) concept is used to determine the fracture toughness of PVC foam core sandwich...

  5. Fracture Characterization of PVC Foam Core Sandwich Specimen Using the DCB-UBM Test Method

    DEFF Research Database (Denmark)

    Saseendran, Vishnu; Berggreen, Christian; Carlsson, Leif A.

    coupled with experimental validation is paramount to determine the fracture resistance of the face/core interface. In this paper, the test-rig exploiting the double cantilever beam with uneven bending moments (DCB-UBM) concept is used to determine the fracture toughness of PVC foam core sandwich...

  6. A Simple and Specific Noncompetitive ELISA Method for HT-2 Toxin Detection

    Directory of Open Access Journals (Sweden)

    Henri O. Arola

    2017-04-01

    Full Text Available We developed an HT-2 toxin-specific simple ELISA format with a positive read-out. The assay is based on an anti-immune complex (IC scFv antibody fragment, which is genetically fused with alkaline phosphatase (AP. The anti-IC antibody specifically recognizes the IC between a primary anti-HT-2 toxin Fab fragment and an HT-2 toxin molecule. In the IC ELISA format, the sample is added together with the scFv-AP antibody to the ELISA plate coated with the primary antibody. After 15 min of incubation and a washing step, the ELISA response is read. A competitive ELISA including only the primary antibody recognizes both HT-2 and T-2 toxins. The anti-IC antibody makes the assay specific for HT-2 toxin, and the IC ELISA is over 10 times more sensitive compared to the competitive assay. Three different naturally contaminated matrices: wheat, barley and oats, were used to evaluate the assay performance with real samples. The corresponding limits of detection were 0.3 ng/mL (13 µg/kg, 0.1 ng/mL (4 µg/kg and 0.3 ng/mL (16 µg/kg, respectively. The IC ELISA can be used for screening HT-2 toxin specifically and in relevant concentration ranges from all three tested grain matrices.

  7. DPI-ELISA: a fast and versatile method to specify the binding of plant transcription factors to DNA in vitro

    Directory of Open Access Journals (Sweden)

    Chaban Christina

    2010-11-01

    Full Text Available Abstract Background About 10% of all genes in eukaryote genomes are predicted to encode transcription factors. The specific binding of transcription factors to short DNA-motifs influences the expression of neighbouring genes. However, little is known about the DNA-protein interaction itself. To date there are only a few suitable methods to characterise DNA-protein-interactions, among which the EMSA is the method most frequently used in laboratories. Besides EMSA, several protocols describe the effective use of an ELISA-based transcription factor binding assay e.g. for the analysis of human NFκB binding to specific DNA sequences. Results We provide a unified protocol for this type of ELISA analysis, termed DNA-Protein-Interaction (DPI-ELISA. Qualitative analyses with His-epitope tagged plant transcription factors expressed in E. coli revealed that EMSA and DPI-ELISA result in comparable and reproducible data. The binding of AtbZIP63 to the C-box and AtWRKY11 to the W2-box could be reproduced and validated by both methods. We next examined the physical binding of the C-terminal DNA-binding domains of AtWRKY33, AtWRKY50 and AtWRKY75 to the W2-box. Although the DNA-binding domain is highly conserved among the WRKY proteins tested, the use of the DPI-ELISA discloses differences in W2-box binding properties between these proteins. In addition to these well-studied transcription factor families, we applied our protocol to AtBPC2, a member of the so far uncharacterised plant specific Basic Pentacysteine transcription factor family. We could demonstrate binding to GA/TC-dinucleotide repeat motifs by our DPI-ELISA protocol. Different buffers and reaction conditions were examined. Conclusions We successfully applied our DPI-ELISA protocol to investigate the DNA-binding specificities of three different classes of transcription factors from Arabidopsis thaliana. However, the analysis of the binding affinity of any DNA-binding protein to any given DNA

  8. The use of enzyme linked immunosorbent assay (ELISA) and direct fluorescent antibody (DFA) methods for diagnosis of Giardia intestinalis.

    Science.gov (United States)

    Al, Funda Doğruman; Kuştimur, Semra; Ozekinci, Tuncer; Balaban, Neriman; Ilhan, Mustafa Necmi

    2006-01-01

    The aim of this study was to evaluate the value of the direct fluorescent antibody (DFA) techniques reported to have high sensitivity and specificity and the enzyme linked immunosorbent assay (ELISA) test used to determine antigens in stool samples in the routine diagnosis of Giardia intestinalis. When 44 stool samples in which G. intestinalis cysts and/or trophozoites had been seen during native Lugol examination were investigated, positivity detected with the trichrome staining method, monoclonal ELISA method and monoclonal DFA method was found to be 37 (84.0%), 39 (88.6%) and 35 (79.5%) respectively. DFA detected Crytosporidium parvum cysts in addition to G. intestinalis in one sample. Twenty-seven (61.4%) of the samples were positive with all three methods. When compared with the DFA method, the ELISA method had a sensitivity of 88.6%, a specificity of 88.8%, a positive predictive value of 79.5% and a negative predictive value of 20.0% while the trichrome staining method had a sensitivity of 85.7%, a specificity of 77.8%, a positive predictive value of 81.1% and a negative predictive value of 22.2%. There was no statistically significant difference between the DFA and ELISA tests and between the DFA test and the trichrome staining method for diagnosing G. intestinalis (p > 0.05).

  9. Antibody-nanoparticle conjugates to enhance the sensitivity of ELISA-based detection methods.

    Directory of Open Access Journals (Sweden)

    Margaret M Billingsley

    Full Text Available Accurate antigen detection is imperative for clinicians to diagnose disease, assess treatment success, and predict patient prognosis. The most common technique used for the detection of disease-associated biomarkers is the enzyme linked immunosorbent assay (ELISA. In an ELISA, primary antibodies are incubated with biological samples containing the biomarker of interest. Then, detectible secondary antibodies conjugated with horseradish peroxidase (HRP bind the primary antibodies. Upon addition of a color-changing substrate, the samples provide a colorimetric signal that directly correlates to the targeted biomarker concentration. While ELISAs are effective for analyzing samples with high biomarker content, they lack the sensitivity required to analyze samples with low antigen levels. We hypothesized that the sensitivity of ELISAs could be enhanced by replacing freely delivered primary antibodies with antibody-nanoparticle conjugates that provide excess binding sites for detectible secondary antibodies, ultimately leading to increased signal. Here, we investigated the use of nanoshells (NS decorated with antibodies specific to epidermal growth factor receptor (EGFR as a model system (EGFR-NS. We incubated one healthy and two breast cancer cell lines, each expressing different levels of EGFR, with EGFR-NS, untargeted NS, or unconjugated EGFR antibodies, as well as detectable secondary antibodies. We found that EGFR-NS consistently increased signal intensity relative to unconjugated EGFR antibodies, with a substantial 13-fold enhancement from cells expressing high levels of EGFR. Additionally, 40x more unconjugated antibodies were required to detect EGFR compared to those conjugated to NS. Our results demonstrate that antibody-nanoparticle conjugates lower the detection limit of traditional ELISAs and support further investigation of this strategy with other antibodies and nanoparticles. Owing to their enhanced sensitivity, we anticipate that

  10. Research on a Novel Exciting Method for a Sandwich Transducer Operating in Longitudinal-Bending Hybrid Modes.

    Science.gov (United States)

    Liu, Yingxiang; Shen, Qiangqiang; Shi, Shengjun; Deng, Jie; Chen, Weishan; Wang, Liang

    2017-06-27

    A novel exciting method for a sandwich type piezoelectric transducer operating in longitudinal-bending hybrid vibration modes is proposed and discussed, in which the piezoelectric elements for the excitations of the longitudinal and bending vibrations share the same axial location, but correspond to different partitions. Whole-piece type piezoelectric plates with three separated partitions are used, in which the center partitions generate the first longitudinal vibration, while the upper and lower partitions produce the second bending vibration. Detailed comparisons between the proposed exciting method and the traditional one were accomplished by finite element method (FEM) calculations, which were further verified by experiments. Compared with the traditional exciting method using independent longitudinal ceramics and bending ceramics, the proposed method achieves higher electromechanical coupling factors and larger vibration amplitudes, especially for the bending vibration mode. This novel exciting method for longitudinal-bending hybrid vibrations has not changed the structural dimensions of the sandwich transducer, but markedly improves the mechanical output ability, which makes it very helpful and meaningful in designing new piezoelectric actuators operated in longitudinal-bending hybrid vibration modes.

  11. Atomic force microscopy analysis of IgG films at hydrophobic surfaces: a promising method to probe IgG orientations and optimize ELISA tests performance.

    Science.gov (United States)

    de Thier, Pierre; Bacharouche, Jalal; Duval, Jérôme F L; Skali-Lami, Salaheddine; Francius, Grégory

    2015-02-01

    IgG films are widely used in the field of immunoassays, especially in (double) antibody-sandwich ELISA tests where capture antibodies are coated on surfaces like polystyrene or hydrophobic self-assembled monolayers (h-SAMs). It is critical to analyze-at a molecular scale and under liquid conditions-the structure of the deposited IgG film in order to quantitatively address the efficiency of the ELISA test in terms of antigen detection. In this communication, we report an atomic force microscopy (AFM) analysis evidencing a strong relationship between immunological activities of mouse monoclonal anti-human interleukin-2 (IL-2) and 6 (IL-6) antibodies, thickness and roughness of the IgG monolayer adsorbed onto h-SAMs, and surface concentration of IgG molecules. Indirect information may be further obtained on antibody orientation. Collating the results obtained by AFM and those from ELISA tests leads us to conclude that antibodies like anti-IL-6 forming flat monolayers should be more efficient under ELISA detection conditions. In addition, the concentration of IgG in the coating suspension should be optimized to obtain a monolayer heavily populated by "end-on" adsorbed molecules, an orientation that is desirable for enhancing ELISA tests performance. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. [Prokaryotic expression of HN gene of bovine parainfluenza virus type 3 and the establishment of indirect ELISA method].

    Science.gov (United States)

    Zhou, Yu-Long; Ren, Ya-Chao; Zhu, Zhan-Bo; Hou, Xi-Lin; Wang, Mi; Geng, Jing; Piao, Fan-Ze; Li, Sen

    2012-01-01

    The prokaryotic expression plasmid pQE30-HN of hemagglutinin-neuraminidase (HN) protein gene of bovine parainfluenza virus type 3 (BPIV3) strain HJ-1 was expressed by IPTG induction in E. coli XL1Blue. The recombinant HN protein(rHN) was purified by electroeluting method, and used as coated antigen. An indirect enzyme-linked immunosorbent assay (ELISA) was developed to detect the antibody valence of BPIV3. The best working conditions of ELISA were as follows: the antigen concentration was 6 microg/mL; the serum dilution was 1:50; the blocking reagent was 5% skimmed milk; the blocking time was 60 min at 37 degrees C; the second antibody concentration was 1:10 000; The cut-off value was 0.30. The method revealed a good specificity, no cross-reaction to the positive sera of BCV, IBRV or BRSV was observed. We applied the method to detect 323 serum samples of dairy cow in Heilongjiang Province, the seropositivity rate of BPIV3 was about 58%. The indirect ELISA established provided a technological basis for the development of ELISA kit.

  13. [Levels of Ochratoxin A and total Aflatoxins in Panamanian exportation coffee by an ELISA Method].

    Science.gov (United States)

    Franco, Heriberto; Vega, Aracelly; Reyes, Stephany; De Léon, Javier; Bonilla, Alexis

    2014-03-01

    A study about processing conditions of exportation coffee in 15 benefits located in Chiriqui, western region of Panama, was conducted. In addition, 21 samples of processed coffee (green beans), from the benefits, were analyzed. The samples were microbiologically tested in order to quantify total aflatoxins (B1, B2, G1 and G2) and Ochratoxin A (OTA), using the immunoaffinity ELISA method. A detection limit of 0.017 ng/mL, was determined for Ochratoxin A, which is equivalent to a concentration of 0.829 µg/kg, and a detection limit of 0.027 ng/mL, for total aflatoxins, which is equivalent to a concentration of 1.350 µg/kg. It was found that four (19%) out of the 21 samples were positive to the presence of Ochratoxin A and three (14%) to the presence of total aflatoxins. Samples showed levels of Ochratoxin A in the range 4.90 - 37.73 µg/kg; only three of them exceeded the maximum limit allowed by the European Union, for the concentration of Ochratoxin, which is of 5.0 µg/kg. Total aflatoxins were found in the range 1.51 - 1.93 µg/kg, below 10 µg/kg which is the maximum limit allowed for coffee by the European Union. The results indicate that the processing of coffee produced in Panama successfully meets international standards for postharvest handling, which leads to a low incidence ofmycotoxins and very low levels ofmycotoxin-producing fungi.

  14. Structural and failure mechanics of sandwich composites

    CERN Document Server

    Carlsson, LA; Carlsson, Leif A

    2011-01-01

    Focusing on important deformation and failure modes of sandwich structures, this volume describes the mechanics behind fracture processes. The text also reviews test methods developed for the cr, structural integrity, and failure mechanisms of sandwich structures.

  15. Semi-in situ atomic force microscopy imaging of intracellular neurofilaments under physiological conditions through the 'sandwich' method.

    Science.gov (United States)

    Sato, Fumiya; Asakawa, Hitoshi; Fukuma, Takeshi; Terada, Sumio

    2016-08-01

    Neurofilaments are intermediate filament proteins specific for neurons and characterized by formation of biochemically stable, obligate heteropolymers in vivo While purified or reassembled neurofilaments have been subjected to morphological analyses by electron microscopy and atomic force microscopy, there has been a need for direct imaging of cytoplasmic genuine intermediate filaments with minimal risk of artefactualization. In this study, we applied the modified 'cells on glass sandwich' method to exteriorize intracellular neurofilaments, reducing the risk of causing artefacts through sample preparation. SW13vim(-) cells were double transduced with neurofilament medium polypeptide (NF-M) and alpha-internexin (α-inx). Cultured cells were covered with a cationized coverslip after prestabilization with tannic acid to form a sandwich and then split into two. After confirming that neurofilaments could be deposited on ventral plasma membranes exposed via unroofing, we performed atomic force microscopy imaging semi-in situ in aqueous solution. The observed thin filaments, considered to retain native structures of the neurofilaments, exhibited an approximate periodicity of 50-60 nm along their length. Their structural property appeared to reflect the morphology formed by their constituents, i.e. NF-M and α-inx. The success of semi-in situ atomic force microscopy of exposed bona fide assembled neurofilaments through separating the sandwich suggests that it can be an effective and alternative method for investigating cytoplasmic intermediate filaments under physiological conditions by atomic force microscopy. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Estimation of ion-site association constants in ion-selective electrode membranes by modified segmented sandwich membrane method

    Energy Technology Data Exchange (ETDEWEB)

    Peshkova, Maria A.; Korobeynikov, Anton I.; Mikhelson, Konstantin N. [St. Petersburg State University, St. Petersburg (Russian Federation)

    2008-08-01

    A method aimed at potentiometric estimation of the association of ions with ion-exchanger sites and charged ionophores in ion-selective electrode membranes is proposed. The method relies on the measurements of segmented sandwich membrane potentials. It is shown theoretically that the quantification of ion association requires use of weakly associated ionic additive whose concentration in the working segment of the sandwich must be varied. This is in contrast with well-established technique of ion to neutral ionophore complexation measurements. The advantages and limitations of the novel method are critically evaluated. Association of ions in plasticized poly(vinylchloride) membranes is studied experimentally. Experimental results are provided related to the association of K{sup +}, Na{sup +}, Cs{sup +}, and NH{sub 4}{sup +}, and also Ca{sup 2+} with commonly used sites: tetra(p-Cl-phenyl)borate anion and calcium-selective lipophilic ion-exchanger bis[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphate. (author)

  17. Buckyball sandwiches.

    Science.gov (United States)

    Mirzayev, Rasim; Mustonen, Kimmo; Monazam, Mohammad R A; Mittelberger, Andreas; Pennycook, Timothy J; Mangler, Clemens; Susi, Toma; Kotakoski, Jani; Meyer, Jannik C

    2017-06-01

    Two-dimensional (2D) materials have considerably expanded the field of materials science in the past decade. Even more recently, various 2D materials have been assembled into vertical van der Waals heterostacks, and it has been proposed to combine them with other low-dimensional structures to create new materials with hybridized properties. We demonstrate the first direct images of a suspended 0D/2D heterostructure that incorporates C 60 molecules between two graphene layers in a buckyball sandwich structure. We find clean and ordered C 60 islands with thicknesses down to one molecule, shielded by the graphene layers from the microscope vacuum and partially protected from radiation damage during scanning transmission electron microscopy imaging. The sandwich structure serves as a 2D nanoscale reaction chamber, allowing the analysis of the structure of the molecules and their dynamics at atomic resolution.

  18. Detection of Lupine (Lupinus spp. L. as a food allergen using three methods: end-point PCR, Real-Time PCR and Elisa

    Directory of Open Access Journals (Sweden)

    Ondrej Revák

    2014-07-01

    Full Text Available The aim of this work was to compare three methods for the detection and quantification of lupine as an allergen in food. The methods that were used in this work were the direct method: ELISA and the indirect methods: end-point PCR and real-time PCR. We examined the detection limit (the sensitivity with which we can detect the presence of the allergen in a sample and the reliability for performing an analysis. We used 17 samples of plant species from a processing plant for dehydrated soups production and lupine samples from lupine processing companies. Its practical use is wide and it is used mainly in the bakery industry, in the manufacture of confectionery, pasta, sauces, as a substitute for soy and also in the production of gluten-free food, because it does not contain gluten. Lupine, however, is also included in the list of 14 allergenic substances, which in accordance with the EU legislation must be listed on food labels. The high risk group, which suffers from primary sensitization or cross-reaction with peanuts, are allergic patients. In the EU, people who are allergic to peanuts range from 0.7 to 1.5%. In experiment 1, we detected the presence of lupine using primers for the detection of α- and δ-conglutine in the samples, using the end-point PCR method and the detection limit of this reaction was at the level of 100 ppm. For the vizualization of the DNA fragments, we used a 2% agarose gel and UV visualizer. In experiment 2 we detected lupine using the TaqMan real-time PCR reaction and primers for the detection of α and δ-conglutine at the level of 10 ppm of lupine in sample. The CP values of lupine using primers for the detection of α-conglutine was 24.85 ± 0.12 and the reliability equation was R2 = 0.9767. The CP lupine values using primers for the detection of δ-conglutine was 22.52 ± 0.17 and the reliability equation was R2 = 0.9925. In experiment 3, we used a sandwich ELISA method for the detection of lupine and the

  19. Measuring Hordein (Gluten) in Beer – A Comparison of ELISA and Mass Spectrometry

    Science.gov (United States)

    Blundell, Malcolm J.; Goswami, Hareshwar P.; Howitt, Crispin A.

    2013-01-01

    Background Subjects suffering from coeliac disease, gluten allergy/intolerance must adopt a lifelong avoidance of gluten. Beer contains trace levels of hordeins (gluten) which are too high to be safely consumed by most coeliacs. Accurate measurement of trace hordeins by ELISA is problematic. Methods We have compared hordein levels in sixty beers, by sandwich ELISA, with the level determined using multiple reaction monitoring mass spectrometry (MRM-MS). Results Hordein levels measured by ELISA varied by four orders of magnitude, from zero (for known gluten-free beers) to 47,000 µg/mL (ppm; for a wheat-based beer). Half the commercial gluten-free beers were free of hordein by MS and ELISA. Two gluten-free and two low-gluten beers had zero ELISA readings, but contained significant hordein levels (pgluten in beverages such as beer and highlights the need for the development of new sensitive and selective quantitative assay such as MS. PMID:23509606

  20. Entamoeba spp. diagnosis in patients with inflmmatory diarrhea by staining, copro-antigen ELISA and multiplex PCR methods

    Directory of Open Access Journals (Sweden)

    Zahra Gharibi

    2017-10-01

    Full Text Available Objective: To evaluate Entamoeba spp. diagnosis in patients with inflammatory diarrhea by staining, copro-antigen ELISA and multiplex PCR methods. Methods: In this descriptive cross-sectional survey, 200 stool samples were randomly collected during 2015–2016. The stool samples were evaluated microscopically for the presence of the parasite using direct and formalin-ether concentration and trichrome staining methods. Then, the stool samples were examined by copro-antigen ELISA (Biomerica Company and multiplex PCR methods. Results: Of 200 samples, 17, 29 and 23 cases were positive for Entamoeba species by the staining, copro-antigen ELISA and multiplex PCR methods, respectively. Of 23 positive samples in multiplex PCR test, 13 and 10 samples were positive for Entamoeba dispar (E. dispar and Entamoeba histolytica (E. histolytica, respectively. Conclusions: Our finding indicated a relatively high prevalence of Entamoeba species in patients with inflammatory diarrhea in Ahvaz city. Due to the complications of E. histolytica/ dispar infection, the health authorities of the city must pay more attention to control and prevent the transmission of E. histolytica/dispar to individuals.

  1. Comparison of two ELISA-based methods for the detection of microcystins in blood serum

    OpenAIRE

    Heussner, Alexandra H.; Winter, Isabell; Altaner, Stefan; Kamp, Lisa; Rubio, Fernando; Dietrich, Daniel R.

    2014-01-01

    Microcystins (MCs) are cyanobacterial toxins which place the public at risk via exposure to MC contaminated water, food or algal food supplements. Subsequent to the fatal intravenous exposure of dialysis patients in Caruaru, Brazil, several techniques (LC–MS, GC–MS and ELISA) were adapted to detect MCs in human serum. As patients chronically exposed to low concentrations of MCs also present with very low MC serum levels, only LC–MS methodology would appear to allow detection of these MC level...

  2. The investigation of Entamoeba histolytica prevalence in some villages of Sivas by ELISA method.

    Science.gov (United States)

    Malatyalı, Erdoğan; Ozçelik, Semra; Celiksöz, Ali

    2011-01-01

    Humans may be infected with three morphologically identical Entamoeba species; pathogenic E. histolytica, commensal E. moshkowskii and E. dispar. The aim of the present study was to determine the true prevalence of the E. histolytica using native lugol, trichrome staining and a monoclonal antigen detection kit (ELISA kit E. histolytica-II; Techlab, Inc., Blacksburg, VA) among primary school children living in the rural areas around Sivas. A total of 1449 stool samples were examined by native lugol and Trichrome staining, and 312 (22%) samples were positive for one or more parasite species. Additionally, 22 (1.5%) stool samples were found to be positive for the presence of E. histolytica/dispar cysts, and these samples were further examined by E. histolytica specific antigen based ELISA. As a result, ELISA test gave negative reactions for all the samples. Also, there was no cross reaction with other luminal protozoa such as E. coli, G. intestinalis, B. hominis and I. butschlii. The data reveals that E. histolytica prevalence may be lower than estimated.

  3. Comparison of four functionalization methods of gold nanoparticles for enhancing the enzyme-linked immunosorbent assay (ELISA

    Directory of Open Access Journals (Sweden)

    Paula Ciaurriz

    2017-01-01

    Full Text Available The enzyme-linked immunosorbent assay (ELISA technique is based on the specific recognition ability of the molecular structure of an antigen (epitope by an antibody and is likely the most important diagnostic technique used today in bioscience. With this methodology, it is possible to diagnose illness, allergies, alimentary fraud, and even to detect small molecules such as toxins, pesticides, heavy metals, etc. For this reason, any procedures that improve the detection limit, sensitivity or reduce the analysis time could have an important impact in several fields. In this respect, many methods have been developed for improving the technique, ranging from fluorescence substrates to methods for increasing the number of enzyme molecules involved in the detection such as the biotin–streptavidin method. In this context, nanotechnology has offered a significant number of proposed solutions, mainly based on the functionalization of nanoparticles from gold to carbon which could be used as antibody carriers as well as reporter enzymes like peroxidase. However, few works have focused on the study of best practices for nanoparticle functionalization for ELISA enhancement. In this work, we use 20 nm gold nanoparticles (AuNPs as a vehicle for secondary antibodies and peroxidase (HRP. The design of experiments technique (DOE and four different methods for biomolecule loading were compared using a rabbit IgG/goat anti-rabbit IgG ELISA model (adsorption, directional, covalent and a combination thereof. As a result, AuNP probes prepared by direct adsorption were the most effective method. AuNPs probes were then used to detect gliadin, one of the main components of wheat gluten, the protein composite that causes celiac disease. With this optimized approach, our data showed a sensitivity increase of at least five times and a lower detection limit with respect to a standard ELISA of at least three times. Additionally, the assay time was remarkably decreased.

  4. Frequency of antiphospholipid antibodies in patients with infectious diseases using three different ELISA methods Freqüência de anticorpos antifosfolípides em pacientes com doenças infecciosas usando três diferentes testes de ELISA

    Directory of Open Access Journals (Sweden)

    Mittermayer Barreto Santiago

    2006-02-01

    Full Text Available OBJECTIVE: The standard enzyme-linked immunosorbent assay (ELISA for anticardiolipin (aCL antibodies is the most important test for the diagnosis of antiphospholipid syndrome (APS. However, the test is also positive in some infectious diseases and other non-related syndromes. It has been suggested that the detection of antibodies to a mixture of phospholipids or to beta2-glycoprotein I (beta2-GP I has higher specificity for APS than the standard aCL ELISA. The aim of the present work is to compare the diagnostic specificity of three different antiphospholipid (aPL assays in patients with infectious diseases. METHODS: Antiphospholipid antibodies were searched by three ELISA techniques, namely standard aCL, APhL® ELISA kit and anti-beta2-GP I, in sera of patients with infectious diseases, including syphilis (69, leptospirosis (33 and visceral leishmaniasis (30. RESULTS: The frequency of positivity of IgG aPL in patients with syphilis, leptospirosis and Kala-azar was 13/69 (19%, 9/33 (27% and 2/30 (6%, respectively, using standard ELISA, versus only 1/69 (1.4%, 0/33 (0% and 0/30 (0% positivity by the APhL® ELISA kit. The positivity of the isotype IgM aPL was 10/69 (14%, 4/33 (12% and 1/30 (3%, respectively, by the standard ELISA, and 1/69 (1.4%, 0/33 (0% and 0/30 (0% by the APhL® ELISA kit. The presence of significant levels of IgG anti-beta2GPI was observed in 14/69 cases of syphilis (20%, 6/33 cases of leptospirosis (18% and 16/30 cases of Kala-azar (53%. The APhL® ELISA kit had superior performance showing the highest specificity: 97% (95% CI: 92%-99% for IgG compared to 81% (95% CI: 74%-87% for standard ELISA and 72% (95% CI: 64%-79% for anti-beta2 GPI assay. CONCLUSIONS: The APhL® ELISA kit proved to be significantly more specific than the aCL standard ELISA and the anti-beta2GPI ELISA, and it should be used to help in the diagnosis and confirmation of APS.OBJETIVO: O ensaio de enzyme-linked immunosorbent assay (ELISA para a pesquisa de

  5. A comparison of ELISA and HPLC methods for determination of ochratoxin A in human blood serum in the Czech Republic.

    Science.gov (United States)

    Dohnal, Vlastimil; Dvořák, Vladimír; Malíř, František; Ostrý, Vladimír; Roubal, Tomáš

    2013-12-01

    Ochratoxin A (OTA) is one of the most naturally occurring fungal toxins in food. It has been detected in high concentrations in serum samples of nephropathic patients and can be applied as one of the markers of potential risk of this disease. Also, OTA can cause adverse effects on human health such as genotoxicity and is anticipated to be a potential human carcinogen. In this study, enzyme-linked immunosorbent assay (ELISA) and high performance liquid chromatography (HPLC) were applied in analysis of 115 blood serum samples of women in the child rearing age from the Czech Republic and both methods were compared. The OTA was presented in a broad range of concentrations from 0.037 to 1.130 μg/L. The outcome of ELISA and HPLC measurements were well correlated (r=0.907). However, it was observed that ELISA tend to result in underestimating the OTA level at the low serum concentrations. Both methods had the same limits of quantification of 0.050 μg/L under standard operation conditions. When OTA concentration in a sample was too low, the sample was redissolved in only 300 μL of methanol and the detection limit for HPLC was lowered to 0.030 μg OTA/L. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. A novel method of measuring leaf epidermis and mesophyll stiffness shows the ubiquitous nature of the sandwich structure of leaf laminas in broad-leaved angiosperm species.

    Science.gov (United States)

    Onoda, Yusuke; Schieving, Feike; Anten, Niels P R

    2015-05-01

    Plant leaves commonly exhibit a thin, flat structure that facilitates a high light interception per unit mass, but may increase risks of mechanical failure when subjected to gravity, wind and herbivory as well as other stresses. Leaf laminas are composed of thin epidermis layers and thicker intervening mesophyll layers, which resemble a composite material, i.e. sandwich structure, used in engineering constructions (e.g. airplane wings) where high bending stiffness with minimum weight is important. Yet, to what extent leaf laminas are mechanically designed and behave as a sandwich structure remains unclear. To resolve this issue, we developed and applied a novel method to estimate stiffness of epidermis- and mesophyll layers without separating the layers. Across a phylogenetically diverse range of 36 angiosperm species, the estimated Young's moduli (a measure of stiffness) of mesophyll layers were much lower than those of the epidermis layers, indicating that leaf laminas behaved similarly to efficient sandwich structures. The stiffness of epidermis layers was higher in evergreen species than in deciduous species, and strongly associated with cuticle thickness. The ubiquitous nature of sandwich structures in leaves across studied species suggests that the sandwich structure has evolutionary advantages as it enables leaves to be simultaneously thin and flat, efficiently capturing light and maintaining mechanical stability under various stresses. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  7. Measurement of shear strength resistance in flexion test on PUR sandwich panels: analysis of difficulties and finite element method simulation

    Directory of Open Access Journals (Sweden)

    J. M. Chillón Moreno

    2017-09-01

    Full Text Available The use of the composite construction elements combining different materials with complementary characteristics, it has spread increasingly. The sandwich panels composed by external metallic sheets that they contributes resistance and core of rigid insulating thermal foam, that provides qualities that improve the thermal comfort inside all kinds of constructions. They are in use in closings and covers that shape the surrounding one of the buildings. Of the different quality controls to which they have to surrender. In this article one proposes an improvement to the indicated one in the procedure for the determination of the resistance to the shear strength, Managing to avoid many anomalous results obtained by the utilization of rigid plates in the supports. Finally, so much the problem observed as the proposed solution, they are modeled and simulate by means of the method of finite elements.

  8. Development of ELISA-based methods to measure the anti-malarial drug chloroquine in plasma and in pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    Ronn Anita

    2011-08-01

    Full Text Available Abstract Background In Central and South America and Eastern and Southern Africa, Plasmodium vivax infections accounts for 71-81% and 5% of malaria cases, respectively. In these areas, chloroquine (CQ remains the treatment of choice for P. vivax malaria. In addition, CQ has recently proven to be an effective HIV-1 therapeutic agent. There is a dire need to continue monitoring quality of CQ as there is a major influx of substandard and fake formulations into malaria-endemic countries. The use of fake/substandard drugs will result in sub-therapeutic levels endangering the patient and possibly select for parasite resistance. The aim of this study was to develop an inexpensive, simple antibody-based ELISA to measure CQ concentrations in tablets and in plasma. Methods A monoclonal antibody (MAb that reacts with the N-side chain of the CQ molecule was prepared by use of a CQ analogue. A specific and reliable ELISA for detection of CQ was developed. The developed assay was validated by measuring CQ in tablets sold in Denmark, India and Sudan. Furthermore, kinetics of CQ concentrations in plasma of four volunteers, who ingested two tablets of Malarex® containing, 250 mg CQ base, were measured before drug intake, three hours later and thereafter at days 1, 3, 7, 14, 21 and 28. The same plasma samples were simultaneously measured by high performance liquid chromatography (HPLC. Results The ELISA proved an easy-to-handle and very sensitive tool for the detection of CQ with a lower limit of detection at 3.9 ng/ml. ELISA levels of CQ in plasma showed high agreement with the levels obtained by HPLC (r = 0.98. The specificity in the negative control group was 100%. Conclusion The developed ELISA can be used for quality screening of CQ in pharmaceutical formulations and for drug monitoring in malaria and in other infectious diseases, such as HIV, where CQ proved to be an effective therapeutic agent. The methodology has been exploited to develop monoclonal

  9. An ELISA for the quantitation of von Willebrand Factor

    DEFF Research Database (Denmark)

    Vinholt, Pernille Just; Overgaard, Martin; Diederichsen, Axel Cosmus Pyndt

    2013-01-01

    BACKGROUND: Von Willebrand factor (VWF) is pivotal in arterial thrombosis, and osteoprotegerin (OPG) is besides being a bone protein also related to cardiovascular diseases. OPG can bind VWF, but the significance of this interaction is not known. OBJECTIVES: The aim was to develop an assay...... for measurement of von Willebrand factor-osteoprotegerin complex (VWF:OPG) in human plasma. Furthermore, the significance of VWF:OPG complex as a marker of cardiovascular disease (CVD) was evaluated. PATIENTS/METHODS: A sandwich ELISA for quantification of VWF:OPG was developed using a polyclonal rabbit anti...

  10. Setting up of a liquid chromatography-high resolution tandem mass spectrometry method for the detection of caseins in food. A comparison with ELISA method

    Directory of Open Access Journals (Sweden)

    Daniela Gastaldi

    2013-06-01

    Full Text Available Determination of caseins in food matrices is usually performed by using the competitiveenzyme- linked immunosorbent assay (ELISA technique. However such a technique suffers from a number of limitations. Among these, the applicability to a narrow concentration range, a non linear (logarithmic response, a non-negligible cross-reactivity and a high cost per kit. At the time of the completion of this study, in case of ELISA positive feedback, there was poor availability in the literature of finding reliable instrumental methods able to determine both qualitatively and quantitatively this class of substances. In the present study, a liquid chromatography-high resolution tandem mass spectrometry (HPLC-HRMS/MS instrumental method was developed with a high resolution mass spectrometer (Orbitrap. Real samples of sausages in which caseins were detected by ELISA technique were analysed. A casein-free sample of ham was used as a blank. The analytical characteristics of the instrumental method were compared with those of a commercial ELISA test, declared specific for α- and β-casein.

  11. Elisa Valero

    OpenAIRE

    Valero Ramos, Elisa

    2009-01-01

    MENOR O IGUAL QUÉ. Los arquitectos, habitualmente aficionados a la matemática sencilla, a los enteros más que a los quebrados, a los módulos, las series, los ejes, las simetrías y las transparencias, admiramos ese oximorón miesiano de ¿menos es más¿ que es, también, el sumum del expresionismo elemental. Y tal vez la arquitecta Elisa Valero, cuya obra autodenominada menor tengo el honor de glosar con estas letras, milita también en este orden de ideas. Educada a partes iguales entre e...

  12. Food allergen analysis for processed food using a novel extraction method to eliminate harmful reagents for both ELISA and lateral-flow tests.

    Science.gov (United States)

    Ito, Kaori; Yamamoto, Takayuki; Oyama, Yuriko; Tsuruma, Rieko; Saito, Eriko; Saito, Yoshikazu; Ozu, Takeshi; Honjoh, Tsutomu; Adachi, Reiko; Sakai, Shinobu; Akiyama, Hiroshi; Shoji, Masahiro

    2016-09-01

    Enzyme-linked immunosorbent assay (ELISA) is commonly used to determine food allergens in food products. However, a significant number of ELISAs give an erroneous result, especially when applied to highly processed food. Accordingly, an improved ELISA, which utilizes an extraction solution comprising the surfactant sodium lauryl sulfate (SDS) and reductant 2-mercaptoethanol (2-ME), has been specially developed to analyze food allergens in highly processed food by enhancing analyte protein extraction. Recently, however, the use of 2-ME has become undesirable. In the present study, a new extraction solution containing a human- and eco-friendly reductant, which is convenient to use at the food manufacturing site, has been established. Among three chemicals with different reducing properties, sodium sulfite, tris(3-hydroxypropyl)phosphine, and mercaptoethylamine sodium sulfite was selected as a 2-ME substitute. The protein extraction ability of SDS/0.1 M sodium sulfite solution was comparable to that of SDS/2-ME solution. Next, the ELISA performance for egg, milk, wheat, peanut, and buckwheat was evaluated by using model-processed foods and commercially available food products. The data showed that the SDS/0.1 M sulfite ELISA significantly correlated with the SDS/2-ME ELISA for all food allergens examined (p food allergens in processed food, showing consistency with the SDS/0.1 M sulfite ELISA results. Accordingly, a harmonized analysis system for processed food comprising a screening LF test and a quantitative ELISA with identical extraction solution has been established. The ELISA based on the SDS/0.1 M sulfite extraction solution has now been authorized as the revised official method for food allergen analysis in Japan.

  13. Measuring hordein (gluten in beer--a comparison of ELISA and mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Gregory J Tanner

    Full Text Available BACKGROUND: Subjects suffering from coeliac disease, gluten allergy/intolerance must adopt a lifelong avoidance of gluten. Beer contains trace levels of hordeins (gluten which are too high to be safely consumed by most coeliacs. Accurate measurement of trace hordeins by ELISA is problematic. METHODS: We have compared hordein levels in sixty beers, by sandwich ELISA, with the level determined using multiple reaction monitoring mass spectrometry (MRM-MS. RESULTS: Hordein levels measured by ELISA varied by four orders of magnitude, from zero (for known gluten-free beers to 47,000 µg/mL (ppm; for a wheat-based beer. Half the commercial gluten-free beers were free of hordein by MS and ELISA. Two gluten-free and two low-gluten beers had zero ELISA readings, but contained significant hordein levels (p<0.05, or near average (60-140% hordein levels, by MS, respectively. Six beers gave false negatives, with zero ELISA readings but near average hordein content by MS. Approximately 20% of commercial beers had ELISA readings less than 1 ppm, but a near average hordein content by MS. Several barley beers also contained undeclared wheat proteins. CONCLUSIONS: ELISA results did not correlate with the relative content of hordein peptides determined by MS, with all barley based beers containing hordein. We suggest that mass spectrometry is more reliable than ELISA, as ELISA enumerates only the concentration of particular amino-acid epitopes; this may vary between different hordeins and may not be related to the absolute hordein concentration. MS quantification is undertaken using peptides that are specific and unique, enabling the quantification of individual hordein isoforms. This outlines the problem of relying solely on ELISA determination of gluten in beverages such as beer and highlights the need for the development of new sensitive and selective quantitative assay such as MS.

  14. A comparison of ELISA methods for the determination of human serum antibodies to Haemophilus influenzae type b

    NARCIS (Netherlands)

    van Gageldonk PGM; Mariani M; Berbers GAM; LVO-BI; Centro Ricerche; CHIRON S.p.A.; Siena; Italy/Laboratorio di Immunochimica e Sierologia Sperimentale/Departimento Immunologia

    1998-01-01

    Een vergelijking tussen de non-competitieve ELISA van Phipps et al., de klassieke radio-antigeen bindings assay (RABA) en de nieuw ontwikkelde Chiron competitieve ELISA voor de bepaling van anti-Hib polysaccharide (HibPs) antistof concentraties in humane sera wordt beschreven in het rapport. Voor

  15. Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of the relative amount of water absorption by various types of structural core materials when immersed or in a high relative humidity environment. This test method is intended to apply to only structural core materials; honeycomb, foam, and balsa wood. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. A serological survey on hepatitis C virus Antibody in blood donors with an ELISA method

    Directory of Open Access Journals (Sweden)

    Tajbakhsh E.

    2007-10-01

    Full Text Available Background: Hepatitis type C virus (HCV is one of the important threatened infectious blood born viruses in different populations. More than 300 million people were suffered form different HCV clinical complications all around the world. It is estimated that only 20% of HCV infected individuals will recover from this viral infection, while the rest become chronically infected. The majority of chronically infected individuals never exhibit symptoms, but approximately 10-/30% of these patients will eventually develop severe liver complications. In this research the prevalence of HCV Ab and the role of some demographic data in HCV incidence and clinical outcomes were determined. Methods: In this retrospective study 11472 blood samples from, Iranian blood donors, Shahrekord city were collected for one year. The frequency of HCV Ab was analyzed with a third generation EIA method. The statistical relationships of different possible risk factors of HCV infection were analyzed by Instat software. Results: The HCV Ab was diagnosed in 69 of 11472 (0.6% serum samples. Significant correlations were detected between the history of HCV infection with marriage, tattooing, and doubtful sexual contact. Significant relationships were not defined between HCV infection with age, history of liver disease, and record of travel to abroad.Conclusions: Significant relationships were find between HCV infection with marital status, history of tattooing and sexual contact, but significant correlations were not find between HCV infections with sex, history of liver disease and traveling to other countries.

  17. Low Velocity Impact Response of Laminated Composite Truncated Sandwich Conical Shells with Various Boundary Conditions Using Complete Model and GDQ Method

    Directory of Open Access Journals (Sweden)

    A. Azizi

    2017-04-01

    Full Text Available In this paper, the dynamic analysis of the composite sandwich truncated conical shells (STCS with various boundary conditions subjected to the low velocity impact was studied analytically, based on the higher order sandwich panel theory. The impact was assumed to occur normally over the top face-sheet, and the contact force history was predicted using two solution models of the motion which were derived based on Hamilton’s principle by considering the displacement continuity conditions between the layers⸳ In order to obtain the contact force and the displacement histories, the differential quadrature method (DQM was used. In this investigation, the effects of different parameters such as the number of layers of the face sheets, the boundary conditions, the semi vertex angle of the cone, and the impact velocity of the impactor on the impact response of the complete model were studied.

  18. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2017-12-18

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. The evaluation of GM6-based ELISA and ICT as diagnostic methods on a Mongolian farm with an outbreak of non-tsetse transmitted horse trypanosomosis.

    Science.gov (United States)

    Davaasuren, Batdorj; Amgalanbaatar, Tovuu; Musinguzi, Simon Peter; Suganuma, Keisuke; Otgonsuren, Davaajav; Mossaad, Ehab; Narantsatsral, Sandagdorj; Battur, Banzragch; Battsetseg, Badgar; Xuan, Xuenan; Inoue, Noboru

    2017-09-15

    Trypanosoma equiperdum, which is the etiological agent of dourine, spreads through sexual intercourse in equines. Dourine (T. equiperdum) has been reported in Mongolia, where it is considered an economically important disease of horses. T. evansi has also been reported in Mongolian domestic animals. The objective of this study was to evaluate the potential application of recombinant T. evansi GM6 (rTeGM6-4r)-based diagnostic methods on a farm with an outbreak of non-tsetse transmitted horse trypanosomosis. Ninety-seven percent homology was found between the amino acid sequences of T. equiperdum GM6 and the GM6 of another Trypanozoon, which also shared the same cellular localization. This finding suggests the utility of rTeGM6-4r-based serodiagnostic methods for epidemiological studies and the diagnosis of both surra and dourine in Equidae. Fifty blood samples were examined from a herd of horses. The diagnostic value of an rTeGM6-4r-based ELISA and an rTeGM6-4r-based immunochromatographic test (ICT) were measured in comparison to a T. evansi crude antigen-based ELISA, which is a diagnostic method recommended by the OIE. However, this is not a perfect diagnostic method for trypanosomosis. Positive serum samples were detected in 46%, 42% and 28% of the tested horses using an rTeGM6-4r-based ELISA, crude antigen-based ELISA and rTeGM6-4r-based ICT, respectively. The sensitivity of rTeGM6-based ELISA was 81%, the specificity was 79%, and the agreement was moderate. We conclude that rTeGM6-4r-based ELISA and ICT represent alternative options for baseline epidemiological studies and the on-site diagnosis of horse trypanosomoses in the field, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Fatigue characterization of Poly Vinyl Chloride (PVC) foam core sandwich composite using the G-control method

    DEFF Research Database (Denmark)

    Manca, Marcello; Berggreen, Christian; Carlsson, Leif A.

    2016-01-01

    This paper presents experimental results from cyclic crack propagation tests performed on sandwich specimens with glass/epoxy face sheets and Poly Vinyl Chloride (PVC) foam cores using the G-controlled cyclic energy release rate (ΔG) test procedure. The face material was tested in tension...... analysis was used to determine the mode-mixity of the crack loading. Experimental crack growth cyclic tests were carried out on pre-cracked mixed-mode bending sandwich specimens with H45, H100 and H160 PVC foam cores under two mode-mixities (mode I and mode II dominant). Post-mortem analysis was performed...... on tested specimens, highlighting the influence of mode mixity and foam density on the crack path. Crack propagation diagrams showing da/dN versus ΔG curves were obtained to establish the Paris-Erdogan relation for each material combination tested at the two mode-mixities. Results showed constant crack...

  1. Investigation of Anti-Toxocara Antibodies in Epileptic Patients and Comparison of Two Methods: ELISA and Western Blotting

    Directory of Open Access Journals (Sweden)

    Mohammad Zibaei

    2013-01-01

    Full Text Available The relationship between Toxocara infection and epilepsy was previously demonstrated by several case-control studies and case reports. These previous studies were often based on the enzyme-linked immunosorbent assay (ELISA using Toxocara excretory-secretory antigens, which are not specific due to cross-reactivity with other parasitic infections such as ascariasis, trichuriasis, and anisakiasis. An immunoblot analysis is highly specific and can detect low levels of Toxocara antibodies. Therefore, this assay may be useful in the identification of toxocariasis in epileptic patients. We examined patients who had epilepsy and healthy subjects for seropositivity for Toxocara infection by ELISA and Western blotting. Out of 85 epileptic patients, 10 (11.8% and 3 (3.5% persons exhibited Toxocara immunoglobulin G (IgG antibodies responses by ELISA and by both techniques, respectively. Moreover, in the healthy group (, 3 (3.5% persons were positive by ELISA, but none was detected by Western blotting. This study indicates that Toxocara infection is a risk factor for epilepsy in Iran. These findings strongly suggest the need to perform Western blotting immunodiagnosis, as well as the ELISA using Toxocara excretory-secretory antigens, to improve diagnosis of human toxocariasis in patients with epilepsy.

  2. Development of a highly sensitive and specific ELISA method for the determination of l-corydalmine in SD rats with monoclonal antibody.

    Science.gov (United States)

    Zhang, Hongwei; Gao, Lan; Shu, Menglin; Liu, Jihua; Yu, Boyang

    2018-01-15

    l-Corydalmine (l-CDL) is a potent analgesic constituent of the traditional Chinese medicine, Rhizoma Corydalis. However, the pharmacokinetic process and tissue distribution of l-CDL in vivo are still unknown. Therefore, it is necessary to establish a simple and sensitive method to detect l-CDL, which will be helpful to study its distribution and pharmacokinetic process. To determine this compound in biological samples, a monoclonal antibody (mAb) against l-CDL was produced and a fast and highly sensitive indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed in this study. The icELISA was applied to determine l-CDL in biological samples. The limit of detection (LOD) of the method was 0.015 ng/mL with a liner range of 1-1000 ng/mL (R2 = 0.9912). The intra- and inter-day precision were below 15% and the recoveries were within 80-117%. Finally, the developed immunoassay was successfully applied to the analysis of the distribution of l-CDL in SD rats. In conclusion, the icELISA based on the anti-l-CDL mAb could be considered as a highly sensitive and rapid method for the determination of l-CDL in biological samples. The ELISA approach may provide a valuable tool for the analysis of small molecules in biological samples. Copyright © 2017. Published by Elsevier B.V.

  3. Development and application of radioimmunoassays and enzyme immunoassays in microbiological and immunological diagnosis. 2. Comparative studies for the detection of toxoplasma antibodies with ELISA, RIA and other serological methods

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, W.A.; Struy, H.; Holzwarth, F. (Medizinische Akademie, Magdeburg (German Democratic Republic))

    1982-06-01

    Comparative studies of indirect immunofluorescence test (IT), complement binding reaction (CBR), enzyme- and radioimmunoassay (ELISA, RIA) for the detection of toxoplasma antibodies in sera of 513 patients are reported. The precision dependent on time, showed coefficients of variation from 3% to 12% (IFT 3%, CBR 10%, ELISA 12%, RIA 7%). The correlation of IFT and ELISA as well as RIA was relatively unfavourable (coefficient of correlation IFT/ELISA r = 0.52, IFT/RIA r = 0.54, RIA/ELISA r = 0.60). The ELISA is the most sensitive method for the detection of antibodies. The specificity of the Toxo-ELISA has to be improved by application of suitable fractions of antigens.

  4. A combination of the Kato-Katz methods and ELISA to improve the diagnosis of clonorchiasis in an endemic area, China.

    Directory of Open Access Journals (Sweden)

    Su Han

    Full Text Available BACKGROUND: Examination of feces by light microscopy is widely used for specific parasitological diagnosis of clonorchiasis. However, the true incidence of infection is underestimated owing to the high missing diagnosis rate of this method. The enzyme-linked immunosorbent assay (ELISA is widely used for the detection and control of clonorchiasis but the practicality of this method is unclear. The purpose of this study was to evaluate the effect of ELISA as a supplementary method for the diagnosis of clonorchiasis. METHODOLOGY/PRINCIPAL FINDINGS: The present study recruited 2,359 clinically suspected patients from Heilongjiang Province, China. In all, 954 cases were identified as antibody-positive by immunoglobulin (IgG-ELISA and 495 individuals were diagnosed as egg-positive by the Kato-Katz (KK method. The seropositive and egg-negative individuals were re-examined by repeated egg counts and/or the number of KK slides and 18 (18.18% cases were confirmed as clonorchiasis. The 40.44%, antibody-positive rate determined by IgG-ELISA was significantly higher (P<0.05 than the 21.75% egg-positive rate found by examination of feces. A Bayesian approach indicated that the prevalence of clonorchiasis in this region was 22.27% and that the sensitivity, specificity, positive predictive value and negative predictive value of IgG-ELISA were 98.7%, 76.53%, 54.66% and 99.52%, respectively. The agreement between the two methods was moderate (kappa value = 0.564. The clonorchiasis patients lived mainly along the Songhua River. The risk factors, except for ethnic factors, were estimated effectively by both methods. CONCLUSIONS/SIGNIFICANCE: The present study suggested that clonorchiasis was widely distributed in Heilongjiang Province, China. The missing diagnosis rate was high using the KK technique alone. The combination of immunological methods and parasitological techniques could improve diagnostic accuracy and reduce the missing diagnosis rate. ELISA used

  5. SIGNS The sandwich sign

    African Journals Online (AJOL)

    214. 5. Kunimasa K, Jo T, Takaiwa T, Ishida T. Thoracic sandwich sign. Intern Med 2011;50:2865. 6. Caceres J, Mata JM, Castaner E, Villanueva A. CT recognition of traumatic herniation of stomach: the sandwich sign. J Thorac Imaging 1995 ...

  6. A rapid method for the detection of representative coliforms in water samples: polymerase chain reaction-enzyme-linked immunosorbent assay (PCR-ELISA).

    Science.gov (United States)

    Kuo, Jong-Tar; Cheng, Chiu-Yu; Huang, Hsiao-Han; Tsao, Chia-Fen; Chung, Ying-Chien

    2010-03-01

    Methods to detect the presence of coliform bacteria in drinking water usually involve a series of complex cultivating steps that are time-consuming and subject to external influences. For this reason, the new 16S rRNA probe has been developed in this study as an alternative detector PCR-ELISA technique that does not involve the culture of bacteria and that is able to detect, identify, and quantify the representative coliform species present in water samples. Our results indicate that this technique is both rapid (detection time of 4 h) and accurate (1.4% error rate). The limit of detection (LOD) was 5 CFU/100 ml for total coliforms, which meets the standards set by most countries for drinking water. Our comparative study demonstrated that this PCR-ELISA method is superior to current conventional methods in terms of detection time, LOD, and accuracy.

  7. Development of ELISA-based methods to measure the anti-malarial drug chloroquine in plasma and in pharmaceutical formulations

    DEFF Research Database (Denmark)

    Khalil, Insaf F; Alifrangis, Michael; Recke, Camilla

    2011-01-01

    In Central and South America and Eastern and Southern Africa, Plasmodium vivax infections accounts for 71-81% and 5% of malaria cases, respectively. In these areas, chloroquine (CQ) remains the treatment of choice for P. vivax malaria. In addition, CQ has recently proven to be an effective HIV-1...... resistance. The aim of this study was to develop an inexpensive, simple antibody-based ELISA to measure CQ concentrations in tablets and in plasma....

  8. Development of an asymmetric PCR-ELISA typing method for citrus tristeza virus based on the coat protein gene.

    Science.gov (United States)

    Nolasco, G; Santos, C; Silva, G; Fonseca, F

    2009-02-01

    The coat protein gene of isolates of citrus tristeza virus (CTV) from 20 citrus-producing regions around the world was amplified by RT-PCR, TA cloned, and characterized by SSCP. Haplotypes that produced different patterns within each geographic region were sequenced and a database of 153 accessions of CTV was assembled. Phylogenetic analysis revealed the existence of seven well-defined clusters (Coefficient of differentiation 0.78). An asymmetric PCR-ELISA typing (APET) assay was developed in the frame of this clustering pattern using a set of eight hybridisation probes. The membership of any unknown haplotype is determined by comparing its pattern of reaction against the whole set of probes and not, as previously done in hybridisation assays, in an all-or-nothing basis. Interpretation of the results is objective and done through a visual basic application that compares the rates of hydrolysis of the ELISA substrate of an assayed isolate to a matrix of rates of hydrolysis obtained from standard haplotypes. This assay was validated and showed a better ability to resolve haplotypes than other assays to which it was compared experimentally. It may be automated to the same extent as any ELISA.

  9. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies.

    Science.gov (United States)

    Parma, Y R; Chacana, P A; Lucchesi, P M A; Rogé, A; Granobles Velandia, C V; Krüger, A; Parma, A E; Fernández-Miyakawa, M E

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx(2EDL933), stx(2vha), stx(2vhb), stx(2g), stx(1EDL933), and stx(1d) were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli.

  10. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Directory of Open Access Journals (Sweden)

    Yanil R Parma

    2012-06-01

    Full Text Available Enterohemorrhagic Escherichia coli (EHEC, a subset of Shiga toxin producing E. coli (STEC is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS. Regardless of serotype, Shiga toxins (Stx1 and/or Stx2 are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx was developed using anti-Stx2 B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933 and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 400 ng /ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for 2 strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli.

  11. Multifunctional sandwich composites

    Science.gov (United States)

    Vaidya, Uday K.

    2003-10-01

    Sandwich composites find increasing use as flexural load bearing lightweight sub-elements in air/space vehicles, rail/ground transportation, marine and sporting goods. The core in these applications is usually balsa wood, foam or honeycomb with laminated carbon or glass facesheets. A limitation of traditional sandwich onfigurations is that the space in the core becomes inaccessible once the facesheets are bonded in place. Significant multi-functional benefits can be obtained by making either the facesheets or the core, space accessible. Multi-functionality is generally referred to as value added to the structure that enhances functions beyond traditional load bearing. Such functions may include sound/vibration damping, ability to route wires or embed sensors. The present work reviews recent work done in enhancing the functionality of the core by use of the space in the core. The damage created by impact to sandwich constructions is always a limiting issue in design. In the present work, low velocity impact (LVI) response of newer/multi-functional sandwich constructions has been studied. Concepts of increasing sandwich core functionality have been reported.

  12. Improved methods for urinary atrazine mercapturate analysis-Assessment of an enzyme-linked immunosorbent assay (ELISA) and a novel liquid chromatography-mass spectrometry (LC-MS) method utilizing online solid phase extraction (SPE)

    Energy Technology Data Exchange (ETDEWEB)

    Koivunen, Marja E. [Department of Entomology and the UC Davis Cancer Center, University of California, Davis (United States); Dettmer, Katja [Department of Entomology and the UC Davis Cancer Center, University of California, Davis (United States); Vermeulen, Roel [Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Rockville, MD (United States); Bakke, Berit [Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Rockville, MD (United States); National Institute of Occupational Health, Oslo (Norway); Gee, Shirley J. [Department of Entomology and the UC Davis Cancer Center, University of California, Davis (United States); Hammock, Bruce D. [Department of Entomology and the UC Davis Cancer Center, University of California, Davis (United States)]. E-mail: bdhammock@ucdavis.edu

    2006-07-21

    Elimination of interfering substances in urine by solid phase extraction (SPE) prior to analysis resulted in 10-fold improvement in the sensitivity of atrazine mercapturate (AM) enzyme-linked immunosorbent assay (ELISA) compared to previous reports. Of the two tested SPE systems, Oasis[reg] HLB and MCX, the mixed-mode MCX gave good recoveries (82%) of AM in spiked samples measured by ELISA, whereas the reverse-phase HLB phase was not compatible with the immunochemical method. At relatively high concentrations of urinary AM (>20 ng mL{sup -1}), sample dilution was effective enough for the elimination of interfering substances. The new liquid chromatography-mass spectrometry (LC-MS) method developed for AM utilizes online-SPE with Oasis[reg] HLB, column switching and a stable-isotope internal standard. The limit of quantification (0.05 ng mL{sup -1}) indicates improved sensitivity compared with most previously published LC-MS methods for AM. Validation of all three methods, LC-MS, ELISA + SPE and ELISA + dilution with spiked urine samples showed good correlation between the known and measured concentrations with R {sup 2} values of 0.996, 0.957 and 0.961, respectively. When a set (n = 70 plus 12 blind duplicates) of urine samples from farmers exposed to atrazine was analyzed, there was a good agreement (R {sup 2} = 0.917) between the log normalized data obtained by ELISA + SPE and LC-MS. High correlation among the data obtained by the two tested methods and the LC-MS method by the Center of Disease Control and Prevention (CDC), together with low variability among the blind duplicates, suggests that both methods reported here would be suitable for the analysis of urinary AM as a biomarker for human exposure of atrazine.

  13. Magnetic particles functionalized with PAMAM-dendrimers and antibodies: a new system for an ELISA method able to detect Ara h3/4 peanut allergen in foods.

    Science.gov (United States)

    Speroni, Francesca; Elviri, Lisa; Careri, Maria; Mangia, Alessandro

    2010-08-01

    An innovative enzyme-linked immunosorbent assay (ELISA) format based on antibody-coated magnetic micro-particles (MPs) for the sensitive detection of Ara h3/4 allergen in food is described. The immunosupport is suspended in the incubation solutions and the MPs with the captured allergen can be easily harvested on a magnet, separated from the solutions, and washed using an easy-to-use, fast and selective approach that allows its detection and quantification. Two differently coated MPs, ProteinA-Pn-b and MP-NH(2)-PAMAM G 1.5-Pn-b immunosupports, were tested. The functionalization of the MPs with PAMAM-sodium carboxylate dendrimers elicits a major stability on the immunoglobulin activity resulting in a threefold enhancement of the analytical sensitivity for the assay with respect to a ProteinA immobilization. Validation was carried out on two different matrices: corn flakes and biscuits. In the case of MP-NH(2)-PAMAM G 1.5 -Pn-b immunosupport, limit of detection was found to be 0.2 mg peanuts/kg matrix in both matrices; the linear response range was demonstrated from 2.5 to 15 mg peanuts/kg matrix by performing statistical tests (homoscedasticity and Mandel fitting tests). Good accuracy and recovery (>80 +/- 2%) were obtained. Different food samples were tested and the results were compared with those obtained with a commercially available ELISA kit. The results obtained in this work demonstrated the applicability of the immunomagnetic ELISA methods on real samples and the possibility to perform the assay with significantly reduced reagent and sample consumption.

  14. Detection of Toxoplasma gondii in raw caprine, ovine, buffalo, bovine, and camel milk using cell cultivation, cat bioassay, capture ELISA, and PCR methods in Iran.

    Science.gov (United States)

    Dehkordi, Farhad Safarpoor; Borujeni, Mohammad Reza Haghighi; Rahimi, Ebrahim; Abdizadeh, Rahman

    2013-02-01

    This study was conducted to determine the presence of Toxoplasma gondii in animal milk samples in Iran. From a total of 395 dairy herds in three provinces of Iran, 66 bovine, 58 ovine, 54 caprine, 33 buffalo, and 30 camel herds were studied, and from these parts of Iran, 200 bovine, 185 ovine, 180 caprine, 164 buffalo, and 160 camel milk samples were collected from various seasons. Samples were tested for Toxoplasma gondii by cell line culture, enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR) technique. Only the results of cell line cultivation were confirmed by bioassay in cat. Results indicated that all herds were infected with Toxoplasma gondii. The culture method showed that 51 out of 889 milk samples (5.73%) were positive for Toxoplasma gondii, and all 51 positive culture results were positive with bioassay in cat. The Fars province had the highest prevalence of Toxoplasma gondii (6.84%). The ELISA test showed that 41 milk samples (4.61%) were positive for the presence of Toxoplasma gondii, while the PCR showed that 46 milk samples were positive for Toxoplasma gondii. The results showed higher sensitivity of PCR and higher specificity of ELISA. Caprine had the highest (10%) and camel had the lowest (3.12%) prevalence rate of parasite. The summer season had the highest (76.47%) but winter (3.92) had the lowest incidence of Toxoplasma gondii. This study is the first prevalence report of direct detection of Toxoplasma gondii in animal milk samples in Iran.

  15. Quantitative Determination of the Glucosinolates Sinigrin and Progoitrin by Specific Antibody ELISA Assays in Brussels Sprouts.

    Science.gov (United States)

    van Doorn HE; van Holst GJ; van Der Kruk GC; Raaijmakers-Ruijs; Postma

    1998-02-16

    Glucosinolates from Brussels sprout samples were extracted using an effective concentration of 2% phosphoric acid followed by a neutralization step and heat treatment for removal of inactivated protein. The (potentially) bitter glucosinolates sinigrin and progoitrin were found to be stable during this new extraction protocol. Antisera, as raised against hemisuccinate-linked glucosinolate conjugates, were very specific in sandwich ELISA assays for their corresponding substrates. The ELISA assays showed maximally 7.4% cross-reactivity to other aliphatic glucosinolates and were log-linear from the nM to µM range. In comparison to the standard HPLC method, the sinigrin and progoitrin ELISA respectively slightly and considerably overestimate the actual content of these glucosinolates. The progoitrin content of samples as determined either with the ELISA assay or by HPLC, however, is highly correlated (r(2) = 0.92, n = 12, p < 0.01), suggesting that the former assay is also applicable for the screening of the progoitrin content in Brussels sprout samples.

  16. Development of a multiplex PCR-ELISA method for the genetic authentication of Thunnus species and Katsuwonus pelamis in food products.

    Science.gov (United States)

    Santaclara, Francisco J; Velasco, Amaya; Pérez-Martín, Ricardo I; Quinteiro, Javier; Rey-Méndez, Manuel; Pardo, Miguel Angel; Jimenez, Elisa; Sotelo, Carmen G

    2015-08-01

    In the present work a PCR-ELISA technique for the authentication of Thunnus species was developed. This method is composed by four systems that can be used in a hierarchical way allowing the identification of several scombroids species; or each individual system independently. The hierarchical strategy, proposes a first step, to assign one sample to the Thunnus genus. Next, if the result is positive, several tests can be applied to assign the sample to some particular species of the Thunnus genus. In the case that the result is negative (absence of Thunnus species), it is possible to verify if Katsuwonus pelamis is included in the sample. The method even allows the detection of mixtures of these species in relatively low amounts (up to 1%). Finally, this method was applied to 11 commercial samples to verify the labelling status of tuna products in the market, detecting that 18% were mislabelling. Copyright © 2015. Published by Elsevier Ltd.

  17. Predicting safe sandwich production

    DEFF Research Database (Denmark)

    Birk, Tina; Duan, Zhi; Møller, Cleide Oliveira de Almeida

    2014-01-01

    Time and temperature control is crucial to avoid growth of pathogens during production and serving of cold ready-to-eat meals. The Danish guidelines state that chilled foods, such as sandwiches, should not be outside the cold chain for more than 3 hours including the time for preparation and serv......Time and temperature control is crucial to avoid growth of pathogens during production and serving of cold ready-to-eat meals. The Danish guidelines state that chilled foods, such as sandwiches, should not be outside the cold chain for more than 3 hours including the time for preparation...... and serving. However, Danish sandwich producing companies find it challenging to comply with this and have expressed a need for more flexibility. The Danish guidelines do allow for a prolongation of the acceptable time outside the cold chain, if the safety of the specific production can be documented....... There is, therefore, room for developing targeted tools for evaluating the time-temperature scenarios in sandwich production. This study describes a decision support tool developed to offer the producers more flexibility. Based on time/temperature measurements obtained during preparation combined...

  18. A novel sandwich hybridization method for selecting cDNAs from large genomic regions: Identification of cDNAs from the cloned genomic DNA spanning the XLRP locus

    Energy Technology Data Exchange (ETDEWEB)

    Yan, D.; McHenry, C.; Fujita, R. [Univ. of Michigan, Ann Arbor, MI (United States)] [and others

    1994-09-01

    We have developed an efficient hybridization-based cDNA-selection method. A sandwich of three species - single-stranded cDNA, tagged RNA derived from genomic DNA, and biotinylated RNA complementary to the tag - allows specific retention of hybrids on an avidin-matrix. Previously, using model experiments, we demonstrated highly specific and efficient selection of a retinal gene, NRL, from complex mixtures of cDNA clones, using a sub-library from a 5 kb NRL genomic clone. We have now applied this selection strategy to isolate cDNAs from human adult retina and fetal eye libraries, with the {open_quotes}genomic RNA{close_quotes} derived from two YAC clones (OTC-C and 55B) spanning the region of X-linked retinitis pigmentosa (XLRP) locus RP3 at Xp21.1. Effectiveness of the selection-method was monitored by enrichment of TCTEX-1L gene that maps within the 55B YAC. Of the 15 selected cDNA clones that hybridized to the 55B YAC DNA, five appear to the map to specific cosmid clones derived from the 55B YAC. Inserts in these selected cDNA clones range from 0.5 to 2.3 kb in size. Additional clones are now being isolated and characterized. This procedure should be independent of the size or complexity of genomic DNA being used for selection, allow for the isolation of full-length cDNAs, and may have wider application.

  19. Rapid screening for glucose-6-phosphate dehydrogenase deficiency and haemoglobin polymorphisms in Africa by a simple high-throughput SSOP-ELISA method

    Directory of Open Access Journals (Sweden)

    Theander Thor G

    2005-12-01

    Full Text Available Abstract Background Mutations in the haemoglobin beta-globin (HbB and glucose-6-phosphate dehydrogenase (G6PD genes cause widespread human genetic disorders such as sickle cell diseases and G6PD deficiency. In sub-Saharan Africa, a few predominant polymorphic variants of each gene account for a majority of these deficiencies. Examining at a larger scale the clinical importance of these independent genetic disorders, their possible association with malaria pathogenesis and innate resistance, and their relevance for antimalarial drug treatment, would be easier if an accurate screening method with limited costs was available. Methods A simple and rapid technique was developed to detect the most prominent single nucleotide polymorphisms (SNPs in the HbB and G6PD genes. The method is able to detect the different haemoglobin polymorphisms A, S, C and E, as well as G6PD polymorphisms B, A and A- based on PCR-amplification followed by a hybridization step using sequence-specific oligonucleotide probes (SSOPs specific for the SNP variants and quantified by ELISA. Results The SSOP-ELISA method was found to be specific, and compared well to the commonly used PCR-RFLP technique. Identical results were obtained in 98% (haemoglobin and 95% (G6PD of the tested 90 field samples from a high-transmission area in Tanzania, which were used to validate the new technique. Conclusion The simplicity and accuracy of the new methodology makes it suitable for application in settings where resources are limited. It would serve as a valuable tool for research purposes by monitoring genotype frequencies in relation to disease epidemiology.

  20. Use of a novel serum ELISA method and the tonsil-carrier state for evaluation of Mycoplasma hyosynoviae distributions in pig herds with or without clinical arthritis

    DEFF Research Database (Denmark)

    Nielsen, Elisabeth Okholm; Lauritsen, Klara Tølbøll; Friis, Niels Filskov

    2005-01-01

    A novel indirect ELISA test using deoxycholate extracted antigens coated onto a hydrophobic polystyrene surface for measurement of serum antibodies specific for Mycoplasma hyosynoviae was developed. Sensitivity and specificity of the test were found to be superior to previous ELISAs as tested...... determined by culture of cross-sectional samples of whole-blood (n = 238) and tonsil scrapings (n = 322), respectively. Levels of serum antibodies (n = 396) were measured by the novel indirect ELISA test. There was no significant difference in the ELISA results between the MhA and the MhC herds. Pigs...... that were tonsil-carriers had a significantly higher response in the ELISA test (P ELISA values (P

  1. A multifunctional heat pipe sandwich panel structure

    Energy Technology Data Exchange (ETDEWEB)

    Queheillalt, Douglas T.; Wadley, Haydn N.G. [University of Virginia, Department of Materials Science and Engineering, 140 Chemistry Way, P.O. Box 400745, Charlottesville, VA 22904 (United States); Carbajal, Gerardo [University of Turabo, School of Engineering, P.O. Box 3030, Gurabo 00778 (Puerto Rico); Peterson, G.P. [University of Colorado at Boulder, 914 Broadway, Boulder, CO 80309 (United States)

    2008-01-15

    A multifunctional sandwich panel combining efficient structural load support and thermal management characteristics has been designed and experimentally assessed. The concept is based upon a truncated, square honeycomb sandwich structure. In closed cell honeycomb structures, the transport of heat from one face to the other occurs by a combination of conduction through the webs and convection/radiation within the cells. Here, much more effective heat transport is achieved by multifunctionally utilizing the core as a heat pipe sandwich panel. Its interior consists of a 6061 aluminum truncated-square honeycomb core covered with a stochastic open-cell nickel foam wick. An electroless nickel plating barrier layer inhibited the chemical reaction between the deionized water working fluid and the aluminum structure, retarding the generation of non-condensable hydrogen gas. A thermodynamic model was used to guide the design of the heat pipe sandwich panel. We describe the results of a series of experiments that validate the operational principle of the multifunctional heat pipe sandwich panel and characterize its transient response to an intense localized heat source. The systems measured thermal response to a localized heat source agrees well with that predicted by a finite difference method model used to predict the thermal response. (author)

  2. Measuring Cohesive Laws for Interfaces in Sandwich Structures

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Sørensen, Bent F.; Berggreen, Carl Christian

    2006-01-01

    mixities. The sandwich specimens consists of glass fiber faces and Divinycell H200 foam core with a pre-crack between face and core made with teflon film. Arbitrary stiffening of the sandwich faces with steel bars adhered to the faces reduces rotations and ensures that the method is useable for a wide...

  3. DETECTION OF OXYTETRACYCLINE IN BROILER CHICKEN MEAT MARKETED IN SEVERAL CITIES IN JAVA ISLAND USING ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA METHOD

    Directory of Open Access Journals (Sweden)

    R. Widiastuti

    2015-09-01

    Full Text Available Oxytetracycline (OTC is one of the tetracycline (TCs broad-spectrum antibiotics widely used inthe chicken industry. However, improper use of OTC with excessive doses potentially leads to residueformation in animal products that can be harmful to consumers in the form of allergic reaction orresistance. This study aimed to detect OTC residues in broiler chicken meat, marketed in traditionalmarkets and supermarkets in Depok, Bekasi, Bandung, Cilegon, Surakarta and Yogyakarta using indirectcompetitive enzyme-linked immunosorbent assay (icELISA method. The analyses of 67 broiler meatsamples showed only 1 (1.5% sample was positive for the OTC residue at 86.1 ng/g which meant belowthe maximum residue limits of permissible OTC (100 ng/g. Nevertheless, a stricter regulation for theuse of OTC in the poultry industry and the monitoring of its residue in chicken products prior tomarketing is still necessary to avoid the adverse effects of the residue present in animal products.

  4. Research And Practice: Quantification Of Raw And Heat-Treated Cow Milk in Sheep Milk, Cheese And Bryndza By ELISA Method

    Directory of Open Access Journals (Sweden)

    Lucia Zeleňáková

    2016-01-01

    Full Text Available The aim of this study was to test the reliability of commercial ELISA tests (RC-bovino within raw and heat treated cow milk detection in sheep milk and cheese in order to obtain a high-quality, reliable and economically beneficial method suitable for routine application in practice. These tests were subsequently used for quantification of cow milk in commercial "Bryndza". Raw sheep milk, cow milk and heat-treated cow milk (pasteurisation at 72 °C for 15 sec or at 85 °C for 3 sec were mixed in precisely defined proportions (0 - 100% cow milk in sheep milk. The milk mixtures were sampled to detect adulteration and subsequently cheese was made. By ELISA tests was possible to determine these amounts of raw cow milk in sheep milk: 0.5% (0.2%, 5 % (4.81%, 50% (42.08% and 75% (56.52%. The pasteurized samples in different combinations gave lower optical density responses than those prepared from raw milk (by approximately 60%. In context with the above mentioned, the relationship between the real and detected amount of cow milk (% in different production stages (milk, cheese using a regression analysis was examined. However, a lower reliability of the detection was indicated by R2 values, which ranged from 0.4058 (cheese to 0.5175 (milk. In practice this means that although individual percentage (% of cow milk in the sample can be detected, but in the unknown sample it can not be clearly confirm whether the cow milk was raw or heat-treated. In this context, the results can be inaccurate and may not correspond to the real situation. Within monitoring phase of this research, 9 samples of bryndza were analysed with the results of detected cow milk ranged from 11.56% to 14.3%. The obtained results confirm that the appropriate selection of ELISA tests can become an important factor in the setting of analytical capabilities for the detection of milk and cheese adulteration.

  5. Validation of a digital photographic method for assessment of dietary quality of school lunch sandwiches brought from home

    DEFF Research Database (Denmark)

    Sabinsky, Marianne; Toft, Ulla; Andersen, Klaus K

    2013-01-01

    were found for fruits and vegetables; BlandAltman analyses showed a tendency to underestimate high amounts of these variables using the DPM. For interrater reliability, kappa statistics ranged from 0.59 to 0.82 across the dietary components and Meal IQ. Conclusions: The standardised DPM is a valid...... from 0.89 to 0.97. The proportion of meals classified in the same or an adjacent quartile ranged from 98% (starch) to 100% (fruits, vegetables, fish, whole grain, and Meal IQ). There was no statistical difference between fish, fat, starch, whole grains, and Meal IQ using the two methods. Differences...

  6. Performance of ELISA and PCR methods for the determination of allergens in food: an evaluation of six years of proficiency testing for soy (Glycine max L.) and wheat gluten (Triticum aestivum L.).

    Science.gov (United States)

    Scharf, Alexandra; Kasel, Udo; Wichmann, Gerhard; Besler, Matthias

    2013-10-30

    For the routine detection of allergens in foods, PCR and/or ELISA methods are employed. To assess the suitability of these methods, proficiency tests (PTs) could be used as a valuable instrument. It is a common practice to evaluate the results with respect to the experimentally obtained robust mean without considering the actual allergen content. In the present study, an overview is given of the results of allergen PTs for the determination of soy and gluten conducted by Dienstleistung Lebensmittel Analytik GbR (DLA). A total of 16 PTs were evaluated with respect to the comparison of PCR and ELISA performances and a new focus on the actually spiked values. The analytes were added in the ranges of 7.8-6264 mg/kg (gluten) and 184-5500 mg/kg (soy protein) in differently composed matrices such as pastry, infant food, and sausage meat. The evaluation of the PTs showed a widely reliable qualitative detection of both allergens by PCR methods. ELISA performances differed for soy and gluten. Although a high number of false-negative results occurred for the detection of soy, the qualitative detection of gluten was appropriate. Quantitative results showed obvious test kit-specific differences for the ELISA methods, but the limits of quantification were suitable for gluten determination. Both ELISA and PCR methods demonstrated their valuable contribution in food allergen determination.

  7. Behaviour of Metal Foam Sandwich Panels

    DEFF Research Database (Denmark)

    Alkhudery, Hayder; Virdi, Kuldeep

    2011-01-01

    Sandwich panels as used in structures comprise of a foam core enclosed by thin high strength steel faces. This paper discusses currently design formulae of local buckling behaviour of such panels using the finite element method. Multiple wave finite element models were adopted to investigate...

  8. Cornelius Elisa Bertus Bremekamp

    NARCIS (Netherlands)

    Lanjouw, J.

    1969-01-01

    Cornelis Elisa Bertus Bremekamp was born at Dordrecht on February 7th 1888. He is therefore now just past eighty, and he has been a member of the Koninklijke Nederlandse Botanische Vereniging for sixty years. He studied at the Utrecht State University and, like many of his contemporaries, was

  9. Comportamento do método quimioluminescente-ELISA em relação a resultados considerados discordantes por meio de três técnicas convencionais para diagnóstico da doença de Chagas Behavior of the chemiluminescent ELISA method in relation to results considered discordant via three conventional techniques for diagnosing Chagas disease

    Directory of Open Access Journals (Sweden)

    Cláudia Regina De Marchi

    2007-02-01

    Full Text Available Quando utilizadas, em conjunto, a hemaglutinação indireta, a imunofluorescência indireta e ELISA para diagnóstico sorológico da doença de Chagas por vezes ocorrem resultados considerados discordantes, por não haver concordância entre o que indicam essas técnicas. A disponibilidade do método quimioluminescente-ELISA permitiu executá-lo com 200 soros que examinados pelos três testes citados que motivaram a obtenção de resultados discordantes. Com o método quimioluminescente-ELISA sucederam 193 negativos e sete positivos. O emprego desse novo procedimento trouxe mais um subsídio para compreensão do assunto, mas avanço mais concreto dependerá de documentação com soros de pessoas infectadas ou não pelo Trypanosoma cruzi conforme comprovação parasitológica.When indirect hemagglutination, indirect immunofluorescence and enzyme-linked immunosorbent assay are used together for serologically diagnosing Chagas disease, results that are considered discordant sometimes occur because there is disagreement between what these tests indicate. The availability of the chemiluminescent ELISA method enabled tests on 200 serum samples that had previously produced discordant results from the three abovementioned methods. CL-ELISA revealed that 193 of these samples were negative and seven were positive. The use of this new procedure provides further support for understanding this subject, but more concrete advances will depend on documentation with blood analyses from people previously demonstrated to be unquestionably infected or uninfected with Trypanosoma cruzi.

  10. Development of New Recombinant DgK Antigen for Diagnosis of Dirofilaria immitis Infections in Dogs Using ELISA Technique and Its Comparison to Molecular Methods

    Science.gov (United States)

    Solgi, Rahmat; Sadjjadi, Seyed Mahmoud; Mohebali, Mehdi; Zarei, Zabihollah; Golkar, Majid; Raz, Abbasali

    2017-10-15

    Dirofilaria immitis is a cosmopolitan zoonotic, vector-borne parasite of carnivorous animals causing dirofilariasis in human beings. Common commercial serodiagnostic tests for canine dirofilariasis usually lead to different results in their sensitivity and specificity. The present study reports development of recombinant DgK (rDgK) antigen of D. immitis for accurate immunodiagnosis of D. Immitis-infected dogs using indirect ELISA test. The rDgK coding sequence was successfully sequenced, codon optimized and cloned in pET-24a(+) expression vector and then expressed in Escherichia coli. The recombinant DgK was affinity purified using Ni²+-charged HiTrap chelating column, followed by testing in Western blotting and enzyme-linked immunosorbent assays (ELISA) with dog sera from a dirofilariasis endemic area. The performance of rDgK ELISA was evaluated using 60 sera collected from suspected dogs, while molecular technique was used as a reference test. Sera from positive control D. immitis infection produced a strong IgG antibody response to rDgK both in ELISA and Western blotting tests. The sensitivity and specificity related to diagnostic potential of rDgK for ELISA were 92.5% and 87.5%, respectively. The results of rDgK ELISA showed a high agreement (0.764) with molecular identification. The findings revealed that the developed new rDgK antigen is sensitive and specific for immunodiagnosis of canine dirofilariasis using ELISA test.

  11. Exploiting Nanobodies in the Detection and Quantification of Human Growth Hormone via Phage-Sandwich Enzyme-Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Hossam Murad

    2017-05-01

    Full Text Available BackgroundMonitoring blood levels of human growth hormone (hGH in most children with short stature deficiencies is crucial for taking a decision of treatment with extended course of daily and expensive doses of recombinant hGH (rhGH or Somatropin®. Besides, misusing of rhGH by sportsmen is banned by the World Anti-Doping Agency and thus sensitive GH-detecting methods are highly welcome in this field. Nanobodies are the tiniest antigen-binding entity derived from camel heavy chain antibodies. They were successfully generated against numerous antigens including hormones.MethodsA fully nanobody-based sandwich ELISA method was developed in this work for direct measurement of GH in biological samples.ResultsTwo major characteristics of nanobody were exploited for this goal: the robust and stable structure of the nanobody (NbGH04 used to capture hGH from tested samples, and the great ability of tailoring, enabling the display of the anti-GH detector nanobody (NbGH07 on the tip of M13-phage. Such huge, stable, and easy-to-prepare phage-Nb was used in ELISA to provide an amplified signal. Previously, NbGH04 was retrieved on immobilized hGH by phage display from a wide “immune” cDNA library prepared from a hGH-immunized camel. Here, and in order to assure epitope heterogeneity, NbGH07 was isolated from the same library using NbGH04-captured hGH as bait. Interaction of both nanobodies with hGH was characterized and compared with different anti-GH nanobodies and antibodies. The sensitivity (~0.5 ng/ml and stability of the nanobody-base sandwich ELISA were assessed using rhGH before testing in the quantification of hGH in blood sera and cell culture supernatants.ConclusionIn regard to all advantages of nanobodies; stability, solubility, production affordability in Escherichia coli, and gene tailoring, nanobody-based phage sandwich ELISA developed here would provide a valuable method for hGH detection and quantification.

  12. Sandwich or sweets?

    DEFF Research Database (Denmark)

    Kraus, Alexandra; Piqueras-Fiszman, Betina

    2016-01-01

    with the use of indirect measurements. However, literature results on the relationship between dynamic, motivational concepts (e.g., approach or avoidance tendencies) and evaluative concepts (e.g., positive or negative associations) remain inconclusive, possibly due to the use of different experimental...... manipulations and methodologies to operationalize these. Our aim with this study is to contribute to this line of research by developing a novel methodology that is based on structurally identical indirect measurement procedures. We measured explicit desire (motivation) and liking (evaluation) of two different...... foods (sandwich and sweets) on visual analogue scales, as well as implicit approach–avoidance tendencies and implicit positive–negative associations with two variants of the recoding-free Implicit Association Tests (IAT-RFs). At first, all participants (N = 108) unwrapped, smelled, and explicitly judged...

  13. Development of a monoclonal antibody TAS-ELISA assay for detection of Phaeomoniella chlamydospora

    Directory of Open Access Journals (Sweden)

    Fernando CARDOSO

    2014-05-01

    Full Text Available Phaeomoniella chlamydospora is an important tracheomycotic fungus involved in different syndromes of the esca disease complex affecting young and mature grapevine plants. Although grapevine planting material is frequently infected by this pathogen, no regular screening to detect the fungus is carried out, mainly due to the lack of fast, sensitive and affordable methods for large-scale application. A monoclonal antibody-based triple antibody sandwich (TAS enzyme-linked immunosorbent assay (ELISA was developed to specifically detect Pa. chlamydospora from grapevine wood tissues. This assay could be especially useful for large-scale application in nurseries, to ensure Pa. chlamydospora-free grapevine stocks, and thus contributing to the production of healthy propagation material.

  14. Wave propagation in sandwich panels with a poroelastic core.

    Science.gov (United States)

    Liu, Hao; Finnveden, Svante; Barbagallo, Mathias; Arteaga, Ines Lopez

    2014-05-01

    Wave propagation in sandwich panels with a poroelastic core, which is modeled by Biot's theory, is investigated using the waveguide finite element method. A waveguide poroelastic element is developed based on a displacement-pressure weak form. The dispersion curves of the sandwich panel are first identified as propagating or evanescent waves by varying the damping in the panel, and wave characteristics are analyzed by examining their motions. The energy distributions are calculated to identify the dominant motions. Simplified analytical models are also devised to show the main physics of the corresponding waves. This wave propagation analysis provides insight into the vibro-acoustic behavior of sandwich panels lined with elastic porous materials.

  15. Sandwich Panel as a Structural Element of Overlap

    Directory of Open Access Journals (Sweden)

    Novikov Maxim

    2016-01-01

    Full Text Available This paper considers the issue of sandwich panels using as load-bearing structural elements. The comparison of deflections and critical failure loads were obtained by the results of the full-scale roof sandwich panels tests conducted by the company “Joris Ide” and the theoretical design, according to the calculation method described in Euronorms. Based on these results it was concluded that sandwich panels can be treated as a load-bearing structure only with more taught manufacturing requirements. Thus, the reduced spread of critical loads can be achieved.

  16. Development of monoclonal antibodies and quantitative ELISAs targeting insulin-degrading enzyme

    Directory of Open Access Journals (Sweden)

    Dickson Dennis W

    2009-10-01

    Full Text Available Abstract Background Insulin-degrading enzyme (IDE is a widely studied zinc-metalloprotease implicated in the pathogenesis of type 2 diabetes mellitus, Alzheimer disease (AD and varicella zoster virus infection. Despite more than six decades of research on IDE, progress has been hampered by the lack of well-characterized reagents targeting this biomedically important protease. To address this important need, we generated and characterized new mouse monoclonal antibodies (mAbs targeting natively folded human and rodent IDE. Results Eight monoclonal hybridoma cell lines were derived in house from mice immunized with full-length, natively folded, recombinant human IDE. The mAbs derived from these lines were shown to detect IDE selectively and sensitively by a wide range of methods. Two mAbs in particular—designated 6A1 and 6H9—proved especially selective for IDE in immunocytochemical and immunohistochemical applications. Using a variety of methods, we show that 6A1 selectively detects both human and rodent IDE, while 6H9 selectively detects human, but not rodent, IDE, with both mAbs showing essentially no cross reactivity with other proteins in these applications. Using these novel anti-IDE mAbs, we also developed sensitive and quantitative sandwich ELISAs capable of quantifying IDE levels present in human brain extracts. Conclusion We succeeded in developing novel mAbs that selectively detect rodent and/or human IDE, which we have shown to be suitable for a wide range of applications, including western blotting, immunoprecipitation, immunocytochemistry, immunohistochemistry, and quantitative sandwich ELISAs. These novel anti-IDE mAbs and the assays derived from them constitute important new tools for addressing many unresolved questions about the basic biology of IDE and its role in multiple highly prevalent human diseases.

  17. Compressive and shear buckling analysis of metal matrix composite sandwich panels under different thermal environments

    Science.gov (United States)

    Ko, William L.; Jackson, Raymond H.

    1993-01-01

    Combined inplane compressive and shear buckling analysis was conducted on flat rectangular sandwich panels using the Raleigh-Ritz minimum energy method with a consideration of transverse shear effect of the sandwich core. The sandwich panels were fabricated with titanium honeycomb core and laminated metal matrix composite face sheets. The results show that slightly slender (along unidirectional compressive loading axis) rectangular sandwich panels have the most desirable stiffness-to-weight ratios for aerospace structural applications; the degradation of buckling strength of sandwich panels with rising temperature is faster in shear than in compression; and the fiber orientation of the face sheets for optimum combined-load buckling strength of sandwich panels is a strong function of both loading condition and panel aspect ratio. Under the same specific weight and panel aspect ratio, a sandwich panel with metal matrix composite face sheets has much higher buckling strength than one having monolithic face sheets.

  18. Iodoacetyl-functionalized pullulan: A supplemental enhancer for single-domain antibody-polyclonal antibody sandwich enzyme-linked immunosorbent assay for detection of survivin.

    Science.gov (United States)

    Matsushita, Takahiko; Arai, Hidenao; Koyama, Tetsuo; Hatano, Ken; Nemoto, Naoto; Matsuoka, Koji

    2017-11-01

    Survivin, an inhibitor of the apoptosis protein family, is a potent tumor marker for diagnosis and prognosis. The enzyme-linked immunosorbent assay (ELISA) is one of the methods that has been used for detection of survivin. However, ELISA has several disadvantages caused by the use of conventional antibodies, and we have therefore been trying to develop a novel ELISA system using camelid single-domain antibodies (VHHs) as advantageous replacements. Here we report a supplemental approach to improve the VHH-polyclonal antibody sandwich ELISA for survivin detection. Iodoacetyl-functionalized pullulan was synthesized, and its thiol reactivity was characterized by a model reaction with l-cysteine. The thiophilic pullulan was applied to an immunoassay asan additive upon coating of standard assay plates with an anti-survivin VHH fusion protein with C-terminal cysteine. The results showed that the mole ratio of the additive to VHH had a significant effect on the consequent response. Mole ratios of 0.07, 0.7, and 7 led to 90% lower, 15% higher, and 69% lower responses, respectively, than the response of a positive control in which no additive was used. The background levels observed in any additive conditions were as low as that of a negative control lacking both VHH and the additive. These results indicate the applicability of the thiol-reactive pullulan as a response enhancer to VHH-based ELISA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. A new ELISA method for serological diagnosis of Legionella pneumophila: use of five purified proteins, FLA, MOMP, MIP, IP, and PILE, as diagnostic antigen.

    Science.gov (United States)

    Sun, Hui; Ma, Haifeng; Liu, Li; Cao, Xiuqin; Yang, Zhiwei

    2015-01-01

    Legionella pneumophila plays an important role in human infection. Commercial ELISA kits commonly used, which take Legionella pneumophila whole-cell protein as the coating antigen, often have cross-reactivity among serogroups or species. In this study, five Legionella pneumophila proteins FLA, MOMP, MIP, IP, and PILE were purified and further applied in serological diagnosis of Legionella pneumophila infections compared with R & D Legionella ELISA kits. The five recombinant plasmids pET-fla, pET-momp, pET-mip, pET-ip, and pET-pile were transformed into E. coli BL21 and then induced them with IPTG. The expression products were analyzed by SDS-PAGE and purified by affinity chromatography. Indirect enzyme-linked immunosorbent assays (ELISAs) were established with the five purified proteins FLA, MOMP, MIP, IP, and PILE altogether as the coating antigen and tested for the presence of IgG, IgM, and IgA antibody independently from 50 positive sera and 40 negative sera, compared with R & D IgG, IgM, and IgA Legionella ELISA kits. The FLA protein about 42 kDa in size, the MOMP protein about 45 kDa, the MIP protein about 40 kDa, the IP protein about 46 kDa, and the PILE protein about 35.7 kDa were separately expressed and purified. Compared with R & D IgG, IgM, and IgA Legionella ELISA kit, the outcome of indirect ELISAs set up with the five purified proteins showed that for IgG the sensitivity was 90.4%, the specificity was 97.4%, the area under ROC curve was 0.939, the kappa value was 0.865, the 95% confidence interval was 0.883 - 0.995. For IgM the sensitivity was 91.8%, the specificity was 95.1%, the area under ROC curve was 0.935, the kappa value was 0.866, the 95% confidence interval was 0.876 - 0.994. For IgA the sensitivity was 93.6%, the specificity was 95.3%, the area under ROC curve was 0.945, the kappa value was 0.889, the 95% confidence interval was 0.890 - 0.999. The proteins FLA, MOMP, MIP, IP, and PILE were successfully expressed and purified, and they seemed

  20. A novel robotic arm driven by sandwich piezoelectric transducers.

    Science.gov (United States)

    Jiang, Zheng; Wang, Liang; Jin, Jiamei

    2018-03-01

    In this work, a novel robotic arm driven by sandwich piezoelectric transducers is proposed. The proposed robotic arm is composed of three arms and four joints. Each arm consists of a sandwich piezoelectric transducer and an H-shaped hollow frame. The sandwich piezoelectric transducer utilizes frictional force to drive the joints on its both sides to rotate simultaneously. The joint between two arms can be driven to rotate in two perpendicular directions by two sandwich piezoelectric transducers. The rotation of joints results in the arm motion. Utilizing the finite element method, the optimized geometrical parameters of the sandwiched piezoelectric transducer are obtained, and the operating principle is demonstrated. A prototype of the robotic arm is also fabricated and assembled, it is 573 g in weight and 412 mm in length, and the maximum rotation angle of each joint is 160°. The mechanical characteristics of the robotic arm prototype are investigated by experiments. The results indicate that, when the excitation frequency of one sandwich piezoelectric transducer is 37.4 kHz, the arms on its two sides rotate in opposite directions with an average rotational velocity of 320 deg/s at 330 V pp , a resolution of 100 μrad at 230 V pp , and a startup and shutdown response time of 40 ms and 30 ms at 230 V pp , respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Modified Mode-I Cracked Sandwich Beam (CSB) Fracture Test

    Science.gov (United States)

    Smith, S. A.; Shivakumar, K. N.

    2001-01-01

    Five composite sandwich panels were fabricated using vacuum assisted resin transfer molding (VARTM). Four of these panels had E-glass/vinylester facesheets and one had carbon/epoxy facesheets. The sandwich panels had different density PVC foam cores. The four E-glass panels had core densities of 80, 100, 130, 200 kg/cu m. The sandwich with carbon/epoxy 3 facesheets had a core with density of 100 kg/cu m. Fracture tests were conducted using a modified Cracked Sandwich Beam (CSB) test configuration. Load displacement curves were obtained for loading and unloading of the specimens during crack growth. Various increments of crack growth were monitored. Critical Strain Energy Release Rates (SERR) were determined from the tests using the area method. The critical values of SERR can be considered the fracture toughness of the sandwich material. The fracture toughness ranged 367 J/sq m to 1350 J/sq m over the range of core densities. These results are compared to the Mode-I fracture toughness of the PVC foam core materials and values obtained for foam-cored sandwiches using the TSD specimen. Finite-element analyses (FEA) were performed for the test configuration and Strain Energy Release Rates were calculated using the Virtual Crack Closure Technique (VCCT). The SERR values determined from the FEA were scaled to the fracture loads, or critical loads, obtained from the modified CSB tests. These critical loads were in close agreement with the test values.

  2. An overview on ELISA techniques for FMD.

    Science.gov (United States)

    Ma, Li-na; Zhang, Jie; Chen, Hao-tai; Zhou, Jian-hua; Ding, Yao-zhong; Liu, Yong-sheng

    2011-09-04

    FMD is one of the major causes of economic loss of cloven-hoofed animals in the world today. The assessment of dominant genotype/lineage and prevalent trends and confirmation the presence of infection or vaccination not only provides scientific basis and first-hand information for appropriate control measure but also for disease eradication and regaining FMD free status following an outbreak. Although different biological and serological approaches are still applied to study this disease, ELISA test based on the distinct format, antigen type and specific antibody reinforce its predominance in different research areas of FMD, and this may replace the traditional methods in the near future. This review gives comprehensive insight on ELISA currently available for typing, antigenic analysis, vaccination status differentiation and surveillance vaccine purity and content at all stages of manufacture in FMDV. Besides, some viewpoint about the recent advances and trends of ELISA reagent for FMD are described here. More than 100 studies regarding ELISA method available for FMD diagnosis, antigenic analysis and monitor were thoroughly reviewed. We investigated previous sagacious results of these tests on their sensitivity, specificity. We found that in all ELISA formats for FMD, antibody-trapping and competitive ELISAs have high specificity and RT-PCR (oligoprobing) ELISA has extra sensitivity. A panel of monoclonal antibodies to different sites or monoclonal antibody in combination of antiserum is the most suitable combination of antibodies in ELISA for FMD. Even though from its beginning, 3ABC is proven to be best performance in many studies, no single NSP can differentiate infected from vaccinated animals with complete confidence. Meanwhile, recombinant antigens and peptide derived from FMDV NPs, and NSPs have been developed for use as an alternative to the inactivated virus antigen for security. There is a need of target protein, which accurately determines the

  3. Elisa Biagini (Florencia, 1970

    Directory of Open Access Journals (Sweden)

    Berta González Saavedra

    2017-01-01

    Full Text Available Elisa Biagini vive en Italia tras haber estudiado y enseñado en los Estados Unidos durante varios años. Sus poesías han sido publicadas en varias revistas y antologías italianas y americanas, entre otras. Algunas de las más recientes son Nuovissima poesia italiana (Mondadori, 2004 y Parola plurale (Sosselam 2005. Ha publicado siete colecciones poéticas, algunas bilingües, entre las que figuran  L'Ospite (Einaudi, 2004, Fiato. Parole per musica (Edizionidif, 2006, Nel bosco (Einaudi, 2007, The guest in the wood (Chelsea editions, 2013 – 2014 Best Translated Book Award, y la reciente Da una crepa (Einaudi, 2014. Sus poesías han sido traducidas al inglés, español, francés, portugués, japonés, croata, eslovaco, alemán, albanés, ruso, árabe y chino. Ha participado en importantes festivales italianos e internacionales (entre otros, en Italia “Festival della Letteratura” de Mantua, “Festival Poesia” de Parma, “RomaPoesia” de Roma, y en el extranjero “Stanza- Scotland's International Poetry Festival” en St. Andrews, Escocia, “Dubai International Poetry Festival” en Emiratos Árabes Unidos, “PoesieFestivalBerlin” en Berlín, “International Writers Workshop” en Hong Kong, “Struga Poetry Festival” en Struga, Macedonia, “Poetry Parnassus” en Londres, “Printemps des poètes” en Luxemburgo, “Queensland Poetry Festival” en Brisbane, Australia, “Festival Internacional de Poesía de Granada” en Nicaragua, “Xu Zhimo Poetry and Art Festival” en el King's College de Cambridge. Asimismo es traductora de poesía americana y, además de editar algunas colecciones de poetisas americanas contemporáneas, se ha encargado de la edición del volumen Nuovi poeti americani (Einaudi, 2006. Infine, insegna Scrittura Creativa (poesia, Travel Writing e Storia dell'Arte in Italia e all’estero, además de colaborar con artistas visules, coreógrafos y músicos. Entre otras actividades, es artista visual. www.elisabiagini.it

  4. High temperature structural sandwich panels

    Science.gov (United States)

    Papakonstantinou, Christos G.

    High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several

  5. Kinetic ELISA in microfluidic channels

    National Research Council Canada - National Science Library

    Yanagisawa, Naoki; Dutta, Debashis

    2011-01-01

    In this article, we describe the kinetic ELISA of Blue Tongue and Epizootic Hemorrhagic Disease viral antibodies in microfluidic channels by monitoring the rate of generation of the enzyme reaction...

  6. Impact damage analysis of balsawood sandwich composite materials

    Science.gov (United States)

    Abdalslam, Suof Omran

    In this study, a new composite sandwich structure with a balsa wood core (end grain and regular balsa) in conjunction with E-glass/epoxy face sheets was proposed, fabricated, impact tested, and modeled. The behavior of the sandwich structure under low velocity impact and compression after impact was investigated. Low velocity impact tests were carried out by drop-weight impact tower at different energy levels (8J-35J) to evaluate the impact response of the sandwich structure. Visual inspection, destructive and non destructive evaluation methods have been conducted. For the sandwich plate with end grain core, the damage was very clear and can be visually detected. However, the damage in regular balsa core was not clearly visible and destructive evaluation method was used. Compression testing was done after subjecting the specimens to impact testing. Impact test results; load-time, load-deflection history and energy absorption for sandwich composites with two different cores, end grain and regular balsa were compared and they were investigated at three different impact energies. The results show that the sandwich structures with end grain core are able to withstand impact loading better than the regular balsa core because the higher stiffness of end grain core informs of sustaining higher load and higher overall energy. The results obtained from compression after impact testing show that the strengths of sandwich composites with end grain and regular balsa cores were reduced about 40% and 52%, respectively, after impact. These results were presented in terms of stress-strain curves for both damaged and undamaged specimens. Finite element analysis was conducted on the sandwich composite structure using LS-DYNA code to simulate impact test. A 3- D finite element model was developed and appropriate material properties were given to each component. The computational model was developed to predict the response of sandwich composite under dynamic loading. The experimental

  7. DETERMINATION OF HISTAMINE IN FISH USING ELISA TECHNIQUE

    NARCIS (Netherlands)

    KRUGER, C; SEWING, U; STENGEL, G; KEMA, [No Value; WESTERMANN, J; MANZ, B

    1995-01-01

    The analysis of histamine in fish and fish products via competitive ELISA is described. The advantages of this method are easy sample preparation and handling, screening capabilities, and low costs. Automation enables the performance of the assay with higher series of samples. The Histamine-ELISA is

  8. (ELISA) kit for diagnosis copro-antigens of Giardia lamblia

    African Journals Online (AJOL)

    STORAGESEVER

    2010-08-02

    Aug 2, 2010 ... was purified by ion-exchange chromatography and conjugated to the enzyme horse radish peroxidase. (HRP). This antibody was used to design direct and indirect ELISA kits to measure conjugation titer. In both direct and indirect ELISA methods, optical densities (ODs) were 1 by using dilution of 1/4000 of.

  9. Comparative Diagnosis of Serum IgG1 and Coproantigen ELISA for Fasciolosis Detection of Goats in Mexico

    Science.gov (United States)

    Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José

    2016-01-01

    The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans. PMID:27563665

  10. Comparative Diagnosis of Serum IgG1 and Coproantigen ELISA for Fasciolosis Detection of Goats in Mexico.

    Science.gov (United States)

    Villa-Mancera, Abel; Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José

    2016-01-01

    The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans.

  11. Comparative Diagnosis of Serum IgG1 and Coproantigen ELISA for Fasciolosis Detection of Goats in Mexico

    Directory of Open Access Journals (Sweden)

    Abel Villa-Mancera

    2016-01-01

    Full Text Available The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P<0.01 for low seropositivity (r=0.93 and medium seropositivity (r=0.84. The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans.

  12. Experimental study on mechanical properties of aircraft honeycomb sandwich structures

    Directory of Open Access Journals (Sweden)

    Talebi Mazraehshahi H.

    2010-06-01

    Full Text Available Mechanical behaviour of sandwich panels under different conditions have been exprimentally studied in this research to increase the knowledge of aircraft sandwich panel structures and facilitate design criteria for aircraft structures. Tests were concentrated on the honeycomb sandwich structures under different loads including flexural, insert shear, flat wise tension and compression loads. Furthermore, effect of core density and face material on mechanical behavior of different samples were investigated and compared with analytical and FEM method. Effects of skin thickness on strength of honycomb sandwhich panels under shear pull out and moments have also been considerd in this study. According to this investigation, insert strength and flexural test under different load conditions is strongly affected by face thickness, but compression and tearoff (falt wise tensile properties of a sandwich panel depends on core material. The study concludes that the correlation between experimental results and the analytical predictions will enable the designer to predict the mechanical behaviour and strength of a sandwich beam; however, applied formula may lead engineers to unreliable results for shear modulus.

  13. Facesheet Delamination of Composite Sandwich Materials at Cryogenic Temperatures

    Science.gov (United States)

    Gates, Thomas S.; Odegard, Gregory M.; Herring, Helen M.

    2003-01-01

    The next generation of space transportation vehicles will require advances in lightweight structural materials and related design concepts to meet the increased demands on performance. One potential source for significant structural weight reduction is the replacement of traditional metallic cryogenic fuel tanks with new designs for polymeric matrix composite tanks. These new tank designs may take the form of thin-walled sandwich constructed with lightweight core and composite facesheets. Life-time durability requirements imply the materials must safely carry pressure loads, external structural loads, resist leakage and operate over an extremely wide temperature range. Aside from catastrophic events like tank wall penetration, one of the most likely scenarios for failure of a tank wall of sandwich construction is the permeation of cryogenic fluid into the sandwich core and the subsequent delamination of the sandwich facesheet due to the build-up of excessive internal pressure. The research presented in this paper was undertaken to help understand this specific problem of core to facesheet delamination in cryogenic environments and relate this data to basic mechanical properties. The experimental results presented herein provide data on the strain energy release rate (toughness) of the interface between the facesheet and the core of a composite sandwich subjected to simulated internal pressure. A unique test apparatus and associated test methods are described and the results are presented to highlight the effects of cryogenic temperature on the measured material properties.

  14. Robust and Air-Stable Sandwiched Organo-Lead Halide Perovskites for Photodetector Applications

    KAUST Repository

    Mohammed, Omar F.

    2016-02-25

    We report the simplest possible method to date for fabricating robust, air-stable, sandwiched perovskite photodetectors. Our proposed sandwiched structure is devoid of electron or hole transporting layers and also the expensive electrodes. These simpler architectures may have application in the perovskite-only class of solar cells scaling up towards commercialization.

  15. Application of a human monoclonal antibody in a rapid competitive anti-HIV ELISA.

    Science.gov (United States)

    Döpel, S H; Porstmann, T; Grunow, R; Jungbauer, A; Von Baehr, R

    1989-01-17

    The ELISA is the established screening technique for the detection of antibodies directed against HIV. The first generation assays, mostly based on the sandwich principle, employed purified virus from cell culture and gave both false-positive and false-negative results. Sandwich-type assays preferentially detect IgG antibodies, require a high serum dilution and are two-step procedures. In order to detect an immune response as early as possible after infection anti-HIV antibodies of the IgM class should also be measured. To this end a competitive ELISA has been developed using a solid phase-adsorbed recombinant HIV envelope protein and an enzyme-labelled human monoclonal antibody. This detects both IgM and IgG antibodies, the results are available within 1 h and a serum predilution is not necessary.

  16. Serotype assignment by sero-agglutination, ELISA, and PCR

    Science.gov (United States)

    For assessing isolates of Listeria monocytogenes serotype designation is the foremost subtyping method used. Traditionally serotyping has been done with agglutination reactions. In the last decade alternative serotyping methods were described using Enzyme Linked Immunosorbent Assay(ELISA)and Polymer...

  17. A novel double antibody sandwich-lateral flow immunoassay for the rapid and simple detection of hepatitis C virus.

    Science.gov (United States)

    Xiang, Tingxiu; Jiang, Zheng; Zheng, Jian; Lo, Chaoyu; Tsou, Harry; Ren, Guosheng; Zhang, Jun; Huang, Ailong; Lai, Guoqi

    2012-11-01

    The objective of this study was to screen for antigens of the hepatitis C virus (HCV) to establish a new double antibody sandwich-lateral flow immunoassay (DAS-LFIA) method for testing the presence of anti-HCV antibodies in human serum or plasma. A series of different recombinant HCV proteins in Escherichia coli cells were constructed, expressed, purified and the new DAS-LFIA strip was developed. The sensitivity and specificity of new the DAS-LFIA strip were evaluated by detecting 23 HCV-positive sera, a set of quality control references for anti-HCV detection that contain known amounts of anti-HCV antibodies, and 8 HCV-negative sera. A total of 300 clinical serum samples was examined by both the new DAS-LFIA strip and enzyme-linked immunosorbent assay (ELISA). Data were analyzed using SPSS 11.5 software. The sensitivity and specificity of the new DAS-LFIA strip were 100%. The lowest test line of the HCV DAS-LFIA strips was 2 NCU/ml. Additionally, the concordance between the new DAS-LFIA strip and ELISA methods was 94.33%. In conclusion, our new testing method is rapid, simple, sensitive and specifically detects the presence of anti-HCV antibodies in human serum or plasma. Therefore, it may be used for monitoring HCV.

  18. Fracture Characterization of Sandwich Face/Core Interfaces

    DEFF Research Database (Denmark)

    Manca, Marcello

    such result it is important to devise new experimental and analytical techniques to establish the multi-mode fracture characteristics of sandwich plate structures and accordingly develop methods to inhibit defect propagation. This thesis deals with characterization of fracture between face and core...... samples. A number of sandwich materials were tested (GFRP/foam cores and CFRP/Nomex) bothin static and fatigue. A linear elastic fracture mechanics model was used to determine the analyticalexpression of compliance which allowed to calculate automatically the crack length. In combination, a finite element...

  19. Measurement of Lipoprotein-Associated Phospholipase A2 by Use of 3 Different Methods: Exploration of Discordance between ELISA and Activity Assays.

    Science.gov (United States)

    Topbas, Celalettin; Swick, Alan; Razavi, Morteza; Anderson, N Leigh; Pearson, Terry W; Bystrom, Cory

    2018-01-10

    Lipoprotein-associated phospholipase A2 (Lp-PLA2), an enzyme associated with inflammation, is used as a biomarker for cardiovascular disease risk. Both the concentration and activity of Lp-PLA2 have been shown to be clinically relevant. However, there is a discordance between the serum concentration of Lp-PLA2 measured by the standard ELISA-based immunoassays and the activity of this enzyme, leading to substantial discordance in risk categorization depending on assay format. We developed 2 LC-MS/MS-based assays to quantify serum Lp-PLA2 activity (multiple reaction monitoring detection of product) and concentration [stable isotope standards and capture by antipeptide antibody (SISCAPA) immunoaffinity], and we investigated their correlation to commercially offered colorimetric activity and immunometric concentrations assays. Associations between Lp-PLA2 and lipoproteins and the effect of selected detergents in liberating Lp-PLA2 were evaluated by use of immunoprecipitation and Western blot analyses. Serum Lp-PLA2 concentrations measured by quantitative SISCAPA-mass spectrometry were substantially higher than concentrations typically measured by immunoassay and showed an improved agreement with Lp-PLA2 activity. With detergents, liberation of Lp-PLA2 from lipoprotein complexes dramatically increased the amount of protein detected by immunoassay and improved the agreement with activity measurements. Quantitative analysis of Lp-PLA2 concentration and activity by LC-MS/MS assays provided key insight into resolving the well-documented discordance between Lp-PLA2 concentration (determined by immunoassay) and activity. Quantitative detection of Lp-PLA2 by immunoassay appears to be strongly inhibited by interaction of Lp-PLA2 with lipoprotein. Together, the results illustrate the advantages of quantitative LC-MS/MS for measurement of Lp-PLA2 concentration (by SISCAPA) and activity (by direct product detection). © 2017 American Association for Clinical Chemistry.

  20. The feasibility of harmonizing gluten ELISA measurements.

    Science.gov (United States)

    Rzychon, Malgorzata; Brohée, Marcel; Cordeiro, Fernando; Haraszi, Reka; Ulberth, Franz; O'Connor, Gavin

    2017-11-01

    Many publications have highlighted that routine ELISA methods do not give rise to equivalent gluten content measurement results. In this study, we assess this variation between results and its likely impact on the enforcement of the EU gluten-free legislation. This study systematically examines the feasibility of harmonizing gluten ELISA assays by the introduction of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurred matrix material. The comparability of measurements is limited by a weak correlation between kit results caused by differences in the selectivity of the methods. This lack of correlation produces bias that cannot be corrected by using reference materials alone. The use of a common calibrator reduced the between-assay variability to some extent, but variation due to differences in selectivity of the assays was unaffected. Consensus on robust markers and their conversion to "gluten content" are required. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Soybean allergen detection methods--a comparison study.

    Science.gov (United States)

    Pedersen, Mona H; Holzhauser, Thomas; Bisson, Caroline; Conti, Amedeo; Jensen, Louise B; Skov, Per S; Bindslev-Jensen, Carsten; Brinch, Ditte S; Poulsen, Lars K

    2008-12-01

    Soybean containing products are widely consumed, thus reliable methods for detection of soy in foods are needed in order to make appropriate risk assessment studies to adequately protect soy allergic patients. Six methods were compared using eight food products with a declared content of soy: a direct sandwich ELISA based on polyclonal rabbit antibody (ab) to raw soy flakes, a commercial and an in-house competitive ELISA both based on ab to denatured, 'renatured' soy protein, an enzyme-allergosorbent test (EAST) inhibition based on two sera from soy allergic patients, histamine release (HR) using basophils passively sensitized with patient serum and a PCR method detecting soy DNA. Eight food products were selected as model foods to test the performance of the methods. There was an overall good agreement between the methods in terms of ranks of soy content but not the quantity. The sandwich ELISA aimed at native soy proteins had the lowest detection limit of 0.05 ppm, but only identified soy in 5/8 products, and generally in lower amounts compared to other methods. The competitive ELISA had a higher detection limit of 21 ppm, but seemed more successful in detecting processed soy. Only HR, EAST inhibition and PCR detected soy in all eight products. In spite of a general good correlation in terms of ranks of soy content, more than a single method may be necessary to confirm the presence of soy in foods.

  2. Development of a new method for the determination of residues of the neonictinoid insecticide imidacloprid in juvenile Chinook (Oncorhynchus tyshawytscha) using ELISA detection

    Science.gov (United States)

    Frew, John A.; Grue, Christian E.

    2012-01-01

    The neonicotinoid insecticide imidacloprid (IMI) has been proposed as an alternative to carbaryl for controlling indigenous burrowing shrimp on commercial oyster beds in Willapa Bay and Grays Harbor, Washington. A focus of concern over the use of this insecticide in an aquatic environment is the potential for adverse effects from exposure to non-target species residing in the Bay, such as juvenile Chinook (Oncorhynchus tshawytscha) and cutthroat trout (O. clarki). Federal registration and State permiting approval for the use of IMI will require confirmation that the compound does not adversely impact these salmonids following field applications. This will necessitate an environmental monitoring program for evaluating exposure in salmonids following the treatment of beds. Quantification of IMI residues in tissue can be used for determining salmonid exposure to the insecticide. Refinement of an existing protocol using liquid-chromatography mass spectrometry (LC-MS) detection would provide the low limits of quantification, given the relatively small tissue sample sizes, necessary for determining exposure in individual fish. Such an approach would not be viable for the environmental monitoring effort in Willapa Bay and Grays Harbor due to the high costs associated with running multiple analyses, however. A new sample preparation protocol was developed for use with a commercially available enzyme-linked immunosorbent assay (ELISA) for the quantification of IMI, thereby providing a low-cost alternative to LC-MS for environmental monitoring in Willapa Bay and Grays Harbor. Extraction of the analyte from the salmonid brain tissue was achieved by Dounce homogenization in 4.0 mL of 20.0 mM Triton X-100, followed by a 6 h incubation at 50–55 °C. Centrifugal ultrafiltration and reversed phase solid phase extraction were used for sample cleanup. The limit of quantification for an average 77.0 mg whole brain sample was calculated at 18.2 μg kg-1 (ppb) with an average

  3. Establishment of optimized ELISA system specific for HLA-G in body fluids.

    Science.gov (United States)

    Ouji-Sageshima, N; Geraghty, D E; Ishitani, A; Hatake, K; Ito, T

    2016-12-01

    Recently, human leukocyte antigen-G (HLA-G) has been a focus in the field of reproductive immunology, tumor progression and transplantation, because of its inhibitory function as ligand to the inhibitory receptors leukocyte immunoglobulin-like receptors (LILR) B1 and LILRB2. The HLA-G is expressed in distinct mRNA isoforms, one of which encodes a soluble HLA-G (sHLA-G) protein, detectable by sandwich ELISA. Therefore, sHLA-G ELISAs have been used as a noninvasive diagnosis system. While a number of sHLA-G-specific ELISAs have been described, our prior studies showed that data obtained by the conventional ELISA system detecting sHLA-G in body fluids was not consistent with the data obtained from immunoprecipitation (IP)/immunoblotting (IB). Therefore, we established an optimized ELISA system described in this report, which yields results consistent with IP/IB analysis. Using this system, we determined sHLA-G protein in amniotic fluids, and found that sHLA-G levels at preterm (∼36 weeks) were clearly higher than those at term (37-41 weeks). These data and supporting experiments showed that the ELISA system we established can be an useful tools for the detection of sHLA-G protein in body fluids than the conventional ELISA system. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Bending and Deformation of Sandwich Panels Due to Localized Pressure

    Directory of Open Access Journals (Sweden)

    Bambang K. Hadi

    2005-05-01

    Full Text Available Bending and deformation of sandwich panels due to localized pressure were analyzed using both Rayleigh-Ritz and finite element methods. The faces were made of laminated composite plates, while the core was a honeycomb material. Carbon fiber and glass fiber reinforced plastics were used for composite plate faces. In the case of Rayleigh-Ritz method, first the total energy of the system was calculated and then taking the variations of the total energy, the sandwich panel deflections could be computed. The deflections were assumed by means of Fourier series. A finite element code NASTRAN was exploited extensively in the finite element method. 3-dimensional 8-node brick elements were used to model sandwich panels, for both the faces sheets and the core. The results were then compared to each other and in general they are in good agreements. Dimple phenomena were found in these cases. It shows that localized pressure on sandwich structures will produce dimple on the pressurize region with little effects on the rest of the structures.

  5. Performance enhancement of sandwich panels with honeycomb–corrugation hybrid core

    Directory of Open Access Journals (Sweden)

    Bin Han

    2016-01-01

    Full Text Available The concept of combining metallic honeycomb with folded thin metallic sheets (corrugation to construct a novel core type for lightweight sandwich structures is proposed. The honeycomb–corrugation hybrid core is manufactured by filling the interstices of aluminum corrugations with precision-cut trapezoidal aluminum honeycomb blocks, bonded together using epoxy glue. The performance of such hybrid-cored sandwich panels subjected to out-of-plane compression, transverse shear, and three-point bending is investigated, both experimentally and numerically. The strength and energy absorption of the sandwich are dramatically enhanced, compared to those of a sandwich with either empty corrugation or honeycomb core. The enhancement is induced by the beneficial interaction effects of honeycomb blocks and folded panels on improved buckling resistance as well as altered crushing modes at large plastic deformation. The present approach provides an effective method to further improve the mechanical properties of conventional honeycomb-cored sandwich constructions with low relative densities.

  6. Comparative Analysis of Human Growth Hormone in Serum Using SPRi, Nano-SPRi and ELISA Assays.

    Science.gov (United States)

    Vance, Stephen; Zeidan, Effat; Henrich, Vincent C; Sandros, Marinella G

    2016-01-07

    Sensitive and selective methods for the detection of human growth hormone (hGH) over a wide range of concentrations (high levels of 50-100 ng ml(-) (1) and minimum levels of 0.03 ng ml(-) (1)) in circulating blood are essential as variable levels may indicate altered physiology. For example, growth disorders occurring in childhood can be diagnosed by measuring levels of hGH in blood. Also, the misuse of recombinant hGH in sports not only poses an ethical issue it also presents serious health threats to the abuser. One popular strategy for measuring hGH misuse, relies on the detection of the ratio of 22 kDa hGH to total hGH, as non-22 kDa endogenous levels drop after exogenous recombinant hGH (rhGH) administration. Surface plasmon resonance imaging (SPRi) is an analytical tool that allows direct (label-free) monitoring and visualization of biomolecular interactions by recording changes of the refractive index adjacent to the sensor surface in real time. In contrast, the most frequently used colorimetric method, enzyme-linked immunosorbent assay (ELISA) uses enzyme labeled detection antibodies to indirectly measure analyte concentration after the addition of a substrate that induces a color change. To increase detection sensitivity, amplified SPRi uses a sandwich assay format and near infrared quantum dots (QDs) to increase signal strength. After direct SPRi detection of recombinant rhGH in spiked human serum, the SPRi signal is amplified by the sequential injection of detection antibody coated with near-infrared QDs (Nano-SPRi). In this study, the diagnostic potential of direct and amplified SPRi was assessed for measuring rhGH spiked in human serum and compared directly with the capabilities of a commercially available ELISA kit.

  7. A sandwich ELISA for measurement of the primary glucagon-like peptide-1 metabolite

    DEFF Research Database (Denmark)

    Wewer Albrechtsen, Nicolai J; Asmar, Ali; Jensen, Frederik

    2017-01-01

    Glucagon-like peptide-1 (GLP-1) is an incretin hormone secreted from the gastrointestinal tract. It is best known for its glucose-dependent insulinotropic effects. GLP-1 is secreted in its intact (active) form (7-36NH2) but is rapidly degraded by the dipeptidyl peptidase 4 (DPP-4) enzyme...... of plasma obtained during intravenous infusions (1.5 pmol × kg(-1) × min(-1)) of GLP-1 7-36NH2 in healthy subjects and patients with type 2 diabetes. Plasma levels of the endogenous GLP-1 metabolite increased during a meal challenge in patients with type 2 diabetes, and treatment with a DPP-4 inhibitor...

  8. Protein unfolding allows use of commercial antibodies in an apolipoprotein M sandwich ELISA

    DEFF Research Database (Denmark)

    Bosteen, Markus Høybye; Dahlbäck, Björn; Nielsen, Lars Bo

    2015-01-01

    apoM is a member of the lipocalin superfamily and circulates in plasma attached to HDL particles. apoM plays a role in cholesterol metabolism and has recently been identified as transporter for the signaling lipid, sphingosine-1-phosphate (S1P), in plasma. S1P is implicated in several inflammatory...

  9. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong [School of Environment and Natural Resources, Renmin University of China, Beijing (China); Shi, Hanchang [School of Environment, Tsinghua University, Beijing (China); Long, Feng, E-mail: longf04@ruc.edu.cn [School of Environment and Natural Resources, Renmin University of China, Beijing (China)

    2016-01-28

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  10. A study on an efficient prediction of welding deformation for T-joint laser welding of sandwich panel Part II: Proposal of a method to use shell element model

    Directory of Open Access Journals (Sweden)

    Jae Woong Kim

    2014-06-01

    Full Text Available I-core sandwich panel that has been used more widely is assembled using high power CO2 laser welding. Kim et al. (2013 proposed a circular cone type heat source model for the T-joint laser welding between face plate and core. It can cover the negative defocus which is commonly adopted in T-joint laser welding to provide deeper penetration. In part I, a volumetric heat source model is proposed and it is verified thorough a comparison of melting zone on the cross section with experiment results. The proposed model can be used for heat transfer analysis and thermal elasto-plastic analysis to predict welding deformation that occurs during laser welding. In terms of computational time, since the thermal elasto-plastic analysis using 3D solid elements is quite time consuming, shell element model with multi-layers have been employed instead. However, the conventional layered approach is not appropriate for the application of heat load at T-Joint. This paper, Part II, suggests a new method to arrange different number of layers for face plate and core in order to impose heat load only to the face plate.

  11. A study on an efficient prediction of welding deformation for T-joint laser welding of sandwich panel Part II : Proposal of a method to use shell element model

    Directory of Open Access Journals (Sweden)

    Kim Jae Woong

    2014-06-01

    Full Text Available I-core sandwich panel that has been used more widely is assembled using high power CO₂laser welding. Kim et al. (2013 proposed a circular cone type heat source model for the T-joint laser welding between face plate and core. It can cover the negative defocus which is commonly adopted in T-joint laser welding to provide deeper penetration. In part I, a volumetric heat source model is proposed and it is verified thorough a comparison of melting zone on the cross section with experiment results. The proposed model can be used for heat transfer analysis and thermal elasto-plastic analysis to predict welding deformation that occurs during laser welding. In terms of computational time, since the thermal elasto-plastic analysis using 3D solid elements is quite time consuming, shell element model with multi-layers have been employed instead. However, the conventional layered approach is not appropriate for the application of heat load at T-Joint. This paper, Part II, suggests a new method to arrange different number of layers for face plate and core in order to impose heat load only to the face plate.

  12. Modelling of Debond and Crack Propagation in Sandwich Structures Using Fracture and Damage Mechanics

    DEFF Research Database (Denmark)

    Berggreen, C.; Simonsen, Bo Cerup; Toernqvist, Rikard

    2003-01-01

    Skin-core de-bonding or core crack propagation will often be dominating mechanisms in the collapse modes of sandwich structures. This paper presents two different methods for prediction of crack propagation in a sandwich structure: a fracture mechanics approach, where a new mode-mix method...... is presented, and a local damage mechanics approach. The paper presents a real-life application example, where the superstructure in a vessel pulls the skin off the sandwich deck. The calculations show almost unstable crack growth initially followed by a stabilization, and a nearly linear relation between...

  13. Advanced Mechanical Testing of Sandwich Materials

    DEFF Research Database (Denmark)

    Hayman, Brian; Berggreen, Christian; Jenstrup, Claus

    2008-01-01

    An advanced digital optical system has been used to measure surface strains on sandwich face and core specimens tested in a project concerned with improved criteria for designing sandwich X-joints. The face sheet specimens were of glass reinforced polyester and were tested in tension. The core sp...

  14. Effect of microencapsulated phase change material in sandwich panels

    Energy Technology Data Exchange (ETDEWEB)

    Castellon, Cecilia; Medrano, Marc; Roca, Joan; Cabeza, Luisa F. [GREA Innovacio Concurrent, Edifici CREA, Universitat de Lleida, Pere de Cabrera s/n, 25001 Lleida (Spain); Navarro, Maria E.; Fernandez, Ana I. [Departamento de Ciencias de los Materiales e Ingenieria Metalurgica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain); Lazaro, Ana; Zalba, Belen [Instituto de Investigacion en Ingenieria de Aragon, I3A, Grupo de Ingenieria Termica y Sistemas Energeticos (GITSE), Dpto. Ingenieria Mecanica, Area de Maquinas y Motores Termicos, Universidad de Zaragoza, Campus Politecnico Rio Ebro, Edificio ' ' Agustin de Betancourt,' ' Maria de Luna s/n, 50018 Zaragoza (Spain)

    2010-10-15

    Sandwich panels are a good option as building materials, as they offer excellent characteristics in a modular system. The goal of this study was to demonstrate the feasibility of using the microencapsulated PCM (Micronal BASF) in sandwich panels to increase their thermal inertia and to reduce the energy demand of the final buildings. In this paper, to manufacture the sandwich panel with microencapsulated PCM three different methods were tested. In case 1, the PCM was added mixing the microencapsulated PCM with one of the components of the polyurethane. In the other two cases, the PCM was added either a step before (case 2) or a step after (case 3) to the addition of the polyurethane to the metal sheets. The results show that in case 1 the effect of PCM was overlapped by a possible increase in thermal conductivity, but an increase of thermal inertia was found in case 3. In case 2, different results were obtained due to the poor distribution of the PCM. Some samples showed the effect of the PCM (higher thermal inertia), and other samples results were similar to the conventional sandwich panel. In both cases (2 and 3), it is required to industrialize the process to improve the results. (author)

  15. Kinetic ELISA in Microfluidic Channels

    Directory of Open Access Journals (Sweden)

    Debashis Dutta

    2011-06-01

    Full Text Available In this article, we describe the kinetic ELISA of Blue Tongue and Epizootic Hemorrhagic Disease viral antibodies in microfluidic channels by monitoring the rate of generation of the enzyme reaction product under static conditions. It has been shown that this format of the immunoassay allows very reliable quantitation of the target species using inexpensive glass microchips and a standard epifluorescence microscope system coupled to a CCD camera. For the viral antibodies assayed here, the limit of detection (LOD for the analyte concentration in our microchips was established to be 3–5 times lower than that obtained on commercial microwell plates using a fiftieth of the sample volume and less than a third of the incubation time. Our analyses further show that when compared to the end-point ELISA format, the kinetic mode of this assay yields an improvement in the LOD by over an order of magnitude in microfluidic devices. This benefit is primarily realized as the observed variation in the background fluorescence (signal at the start of the enzyme reaction period was significantly larger than that in the rate of signal generation upon repeating these assays in different microchannels/microchips. Because the kinetic ELISA results depend only on the latter quantity, the noise level in them was substantially lower compared to that in its end-point counterpart in which the absolute fluorescence measurements are of greater significance. While a similar benefit was also recorded through implementation of kinetic ELISAs on the microwell platform, the improvement in LOD registered in that system was not as significant as was observed in the case of microfluidic assays.

  16. Evaluation of a fast and simple sample preparation method for PBDE flame retardants and DDT pesticides in fish for analysis by ELISA compared with GC-MS/MS

    Science.gov (United States)

    A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography tandem mass spectrometry (LPGC-MS/MS), was evaluated for analysis of polybrominated diphenyl ethers (PBDEs) and dich...

  17. Plasmonic ELISA for the ultrasensitive detection of Treponema pallidum.

    Science.gov (United States)

    Nie, Xin-Min; Huang, Rong; Dong, Cai-Xia; Tang, Li-Juan; Gui, Rong; Jiang, Jian-Hui

    2014-08-15

    In this report, we have developed a plasmonic ELISA strategy for the detection of syphilis. Plasmonic ELISA is an enzyme-linked immunoassay combined with enzyme-mediated surface plasmon resonance (SPR) of gold nanoparticles (AuNPs). Immune response of the Treponema pallidum (T. pallidum) antibodies triggers the acetylcholinesterase-catalyzed hydrolysis of acetylthiocholine to produce abundant thiocholine. The positive charged thiol, in turn, alters the surface charge distribution the AuNPs and leads to the agglomeration of the AuNPs. The induced strong localized SPR effect of the agglomerate AuNPs can, thus, allow the quantitative assay of T. pallidum antibodies due to the remarkable color and absorption spectral response changes of the reaction system. The plasmonic ELISA exhibited a quasilinear response to the logarithmic T. pallidum antibody concentrations in the range of 1pg/mL-10ng/mL with a detection limit of 0.98pg/mL. Such a low detection limit was 1000-fold improvements in sensitivity over a conventional ELISA. The results of plasmonic ELISA in syphilis assays of serum specimens from 60 patients agreed with those obtained using a conventional ELISA method. The plasmonic ELISA has characteristics (analyte specific, cost-effective, ease of automatic, low limit of detection) that provide potential for diagnosis and therapeutic monitoring of syphilis. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Production and characterization of antibodies against crosslinked gelatin nanoparticles and first steps toward developing an ELISA screening kit.

    Science.gov (United States)

    Dehalu, Vincent; Weigel, Stefan; Rebe, Sabina; Grombe, Ringo; Löbenberg, Raimar; Delahaut, Philippe

    2012-07-01

    Nanotechnologies are finding a growing range of applications in the food sector. Nanoparticles are used notably to add vitamins and other nutrients to foods and beverages without affecting taste and color. They are also used to develop new tastes, preserve food texture, control the release of flavors, improve the bioavailability of compounds such as antioxidants and vitamins, and monitor freshness with nanosensors. Crosslinked gelatin nanoparticles are a component of nano-sized carriers for nutrient and supplement delivery in foods and related products. This paper describes the production and characterization of polyclonal antibodies against gelatin nanoparticles. Two immunization schemes were investigated: subcutaneous injection with and without a first intravenous injection. Two enzyme-linked immunosorbent assay formats were used to characterize the antibodies: an inhibition format with an antigen-coated plate for detection of the immune response and a sandwich format for development of the method. The antibodies showed good sensitivity with an IC50 equal to 0.11 ng mL(-1) using indirect ELISA format and a good specificity for the nanomaterials, without significant cross-reactivity against native gelatin. The limit of detection was determined-0.42, 0.27, 0.26, and 0.24 μg mL(-1) for apple, orange juice, milk, and soft drink matrices, respectively. ELISA technology offers rapid, low-cost assays for screening foods, feeds, and beverages. We have studied a prototype ELISA for detection of gelatin-based nanocarrier systems. Fruit juices, milk, and a soft drink were the matrices selected for assay development.

  19. Validated sandwich enzyme-linked immunosorbent assay for casein and its application to retail and milk-allergic complaint foods.

    Science.gov (United States)

    Hefle, Susan L; Lambrecht, Debra M

    2004-09-01

    Cows' milk is a commonly allergenic food. Cross-contamination of milk proteins into nondairy, kosher-pareve foods prepared on shared processing equipment can cause severe, life-threatening reactions in milk-allergic individuals. A sandwich-type enzyme-linked immunosorbent assay (ELISA; 96-well plate format) was developed for the detection of undeclared casein in foods. Rabbit anti-casein antibodies were used as the capture reagent. Food samples and standards were ground, extracted in 0.01 M phosphate-buffered saline, clarified by centrifugation, and added to the wells. Goat anti-casein antibodies were employed as the detector antibody, and the amount of antibody bound was determined with a commercial rabbit anti-goat immunoglobulin conjugated to alkaline phosphatase, with subsequent substrate reaction. Antibodies developed were specific to casein, with no cross-reaction observed with 30 foods and food ingredients. Non-milk-containing products such as fruit juices, fruit juice bars, sorbets, and dark and pareve-labeled chocolate were purchased from June 2002 through June 2003. In addition, samples allegedly causing eight milk-allergic consumer complaints were analyzed. The ELISA had a detection limit of less than 0.5 ppm of casein. The casein content in the analyzed foods ranged from less than 0.5 ppm to more than 40,000 ppm casein; undeclared casein residues were found in all of the samples implicated in allergic reactions. The levels of milk contamination in some of the other surveyed products could also be hazardous for milk-allergic consumers. This ELISA method provides a useful quality control tool for the food industry and could also be used as a validation of kosher-pareve status.

  20. Flexural Behavior of Aluminum Honeycomb Core Sandwich Structure

    Science.gov (United States)

    Matta, Vidyasagar; Kumar, J. Suresh; Venkataraviteja, Duddu; Reddy, Guggulla Bharath Kumar

    2017-05-01

    and has more strength. By the power press used as forming method we fabricate the honey comb core and stacking the sheets with adhesive as epoxy resin or laser beam welding and sandwich structure will form with two face sheets. Then the specimen is taken to be tested to know the flexural behaviour by the flexural test as 3 point and 4 pont bend test. After testing of two different tests then we get the force vs displacement curve by this we can know the maximum force and by loading configurations and its displacement or deflection then we can calculate flexural stiffness and core shear modulus by the variation of three parameters. Our ultimate aim is to achieve maximum strength by minimum weight.

  1. Combined compressive and shear buckling analysis of hypersonic aircraft sandwich panels

    Science.gov (United States)

    Ko, William L.; Jackson, Raymond H.

    1992-01-01

    The combined-load (compression and shear) buckling equations were established for orthotropic sandwich panels by using the Rayleigh-Ritz method to minimize the panel total potential energy. The resulting combined-load buckling equations were used to generate buckling interaction curves for super-plastically-formed/diffusion-bonded titanium truss-core sandwich panels and titanium honeycomb-core sandwich panels having the same specific weight. The relative combined-load buckling strengths of these two types of sandwich panels are compared with consideration of their sandwich orientations. For square and nearly square panels of both types, the combined load always induces symmetric buckling. As the panel aspect ratios increase, antisymmetric buckling will show up when the loading is shear-dominated combined loading. The square panel (either type) has the highest combined buckling strength, but the combined load buckling strength drops sharply as the panel aspect ratio increases. For square panels, the truss-core sandwich panel has higher compression-dominated load buckling strength. However, for shear dominated loading, the square honeycomb-core sandwich panel has higher shear-dominated combined load buckling strength.

  2. Combined compressive and shear buckling analysis of hypersonic aircraft structural sandwich panels

    Science.gov (United States)

    Ko, William L.; Jackson, Raymond H.

    1991-01-01

    The combined-load (compression and shear) buckling equations were established for orthotropic sandwich panels by using the Rayleigh-Ritz method to minimize the panel total potential energy. The resulting combined-load buckling equations were used to generate buckling interaction curves for super-plastically-formed/diffusion-bonded titanium truss-core sandwich panels and titanium honeycomb-core sandwich panels having the same specific weight. The relative combined-load buckling strengths of these two types of sandwich panels are compared with consideration of their sandwich orientations. For square and nearly square panels of both types, the combined load always induces symmetric buckling. As the panel aspect ratios increase, antisymmetric buckling will show up when the loading is shear-dominated combined loading. The square panel (either type) has the highest combined buckling strength, but the combined load buckling strength drops sharply as the panel aspect ratio increases. For square panels, the truss-core sandwich panel has higher compression-dominated combined load buckling strength. However, for shear dominated loading, the square honeycomb-core sandwich panel has higher shear-dominated combined load buckling strength.

  3. Increasing the Sensitivity of ELISA using Multiplexed Electrokinetic Concentrator

    Science.gov (United States)

    Cheow, Lih Feng; Ko, Sung Hee; Kim, Sung Jae; Kang, Kwan Hyoung; Han, Jongyoon

    2010-01-01

    We developed a novel method to increase the sensitivity of standard Enzyme-Linked Immunosorbent Assay (ELISA) using a multiplexed electrokinetic concentration chip. The poly(dimethylsiloxane) (PDMS) molecular concentrator1 was used to trap and collect charged fluorescent product of target-bound enzyme turnover reaction of ELISA that occurred in a standard 96 well plate. Detection sensitivities of both Prostate Specific Antigen (PSA) and CA 19-9 (a human pancreatic and gastrointestinal cancer marker) ELISAs in serum are enhanced ~100 fold with a low CV of electrokinetic accumulation step. This chip can be directly applied to enhance the readout sensitivity of a wide range of existing ELISA kits at concentrations below the current detection limit. PMID:20307052

  4. Modeling of Sensor Placement Strategy for Shape Sensing and Structural Health Monitoring of a Wing-Shaped Sandwich Panel Using Inverse Finite Element Method

    Directory of Open Access Journals (Sweden)

    Adnan Kefal

    2017-11-01

    Full Text Available This paper investigated the effect of sensor density and alignment for three-dimensional shape sensing of an airplane-wing-shaped thick panel subjected to three different loading conditions, i.e., bending, torsion, and membrane loads. For shape sensing analysis of the panel, the Inverse Finite Element Method (iFEM was used together with the Refined Zigzag Theory (RZT, in order to enable accurate predictions for transverse deflection and through-the-thickness variation of interfacial displacements. In this study, the iFEM-RZT algorithm is implemented by utilizing a novel three-node C°-continuous inverse-shell element, known as i3-RZT. The discrete strain data is generated numerically through performing a high-fidelity finite element analysis on the wing-shaped panel. This numerical strain data represents experimental strain readings obtained from surface patched strain gauges or embedded fiber Bragg grating (FBG sensors. Three different sensor placement configurations with varying density and alignment of strain data were examined and their corresponding displacement contours were compared with those of reference solutions. The results indicate that a sparse distribution of FBG sensors (uniaxial strain measurements, aligned in only the longitudinal direction, is sufficient for predicting accurate full-field membrane and bending responses (deformed shapes of the panel, including a true zigzag representation of interfacial displacements. On the other hand, a sparse deployment of strain rosettes (triaxial strain measurements is essentially enough to produce torsion shapes that are as accurate as those of predicted by a dense sensor placement configuration. Hence, the potential applicability and practical aspects of i3-RZT/iFEM methodology is proven for three-dimensional shape-sensing of future aerospace structures.

  5. Modeling of Sensor Placement Strategy for Shape Sensing and Structural Health Monitoring of a Wing-Shaped Sandwich Panel Using Inverse Finite Element Method.

    Science.gov (United States)

    Kefal, Adnan; Yildiz, Mehmet

    2017-11-30

    This paper investigated the effect of sensor density and alignment for three-dimensional shape sensing of an airplane-wing-shaped thick panel subjected to three different loading conditions, i.e., bending, torsion, and membrane loads. For shape sensing analysis of the panel, the Inverse Finite Element Method (iFEM) was used together with the Refined Zigzag Theory (RZT), in order to enable accurate predictions for transverse deflection and through-the-thickness variation of interfacial displacements. In this study, the iFEM-RZT algorithm is implemented by utilizing a novel three-node C°-continuous inverse-shell element, known as i3-RZT. The discrete strain data is generated numerically through performing a high-fidelity finite element analysis on the wing-shaped panel. This numerical strain data represents experimental strain readings obtained from surface patched strain gauges or embedded fiber Bragg grating (FBG) sensors. Three different sensor placement configurations with varying density and alignment of strain data were examined and their corresponding displacement contours were compared with those of reference solutions. The results indicate that a sparse distribution of FBG sensors (uniaxial strain measurements), aligned in only the longitudinal direction, is sufficient for predicting accurate full-field membrane and bending responses (deformed shapes) of the panel, including a true zigzag representation of interfacial displacements. On the other hand, a sparse deployment of strain rosettes (triaxial strain measurements) is essentially enough to produce torsion shapes that are as accurate as those of predicted by a dense sensor placement configuration. Hence, the potential applicability and practical aspects of i3-RZT/iFEM methodology is proven for three-dimensional shape-sensing of future aerospace structures.

  6. New "sandwich" structures conformed from three dimensional

    Directory of Open Access Journals (Sweden)

    Alba, Juan J.

    1996-03-01

    Full Text Available Poor interlaminar properties as well as poor-skin-to-core adhesion properties are very often the common existing problems we find when designing with "sandwich" structures. A new type of 3D-fabric "sandwich" structure is being developed in order to avoid these problems. Although the manufacturing process is very simple, a very complex "sandwich" structure is obtained as a result of the complexity of the 3D-fabric used. This 3D-fabric is a 3D woven glass fabric produced on velvet weaving machines with glass yarns. It is an integrally woven "sandwich" laminate for all kinds of composite products. The strength of the vertical fibers makes, that also after impregnation with a resin matrix, the "sandwich" structure is maintained. The result is a laminate with high strength and stiffness and low weight. On each side of this "sandwich" laminate additional reinforcement materials can be laminated and a synthetic foam can be injected in the hollow structure. This will allow to establish the mechanical properties of a finished product.

    Las pobres propiedades, tanto interlaminares como de adhesión entre piel y núcleo, constituyen uno de los grandes problemas cuando se diseñan estructuras utilizando paneles tipo "sandwich". Un nuevo tipo de panel "sandwich", configurado a partir de tejidos tridimensionales, está siendo desarrollado en la actualidad con el objetivo de eliminar esos problemas. Aunque el proceso de fabricación es muy simple, el panel "sandwich" obtenido es de estructura compleja, como resultado de la complejidad del tejido tridimensional utilizado. Este tejido tridimensional (3D es un tejido de fibra de vidrio producido en máquinas de tejer especializadas. La resistencia de las fibras verticales hace que, después de la impregnación con una resina, se mantenga la configuración tipo "sandwich". El resultado es un laminado de alta resistencia, gran rigidez y bajo peso. Sobre cada uno de los lados del panel "sandwich" se pueden

  7. Non-Uniform Compressive Strength of Debonded Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian; Simonsen, Bo Cerup

    2005-01-01

    This article describes the development, validation and application of a FEM based numerical model for prediction of residual strength of damaged sandwich panels. The core of the theoretical method is a newly developed procedure for prediction of the propagation of a face-core debond. As demonstra......This article describes the development, validation and application of a FEM based numerical model for prediction of residual strength of damaged sandwich panels. The core of the theoretical method is a newly developed procedure for prediction of the propagation of a face-core debond.......(2005)., shows that the model is indeed able to predict the failure modes and the residual strength of damaged panels with accuracy sufficient for practical applications. This opens up for a number of important engineering applications, for example risk-based inspection and repair schemes....

  8. Design of sandwich beams for concentrated loading

    Science.gov (United States)

    Kim, Jongman

    Although sandwich construction offers well-known advantages for high stiffness with light-weight, the problem of designing a sandwich structure to withstand localized loading such as might result from accidental impact, for example, is important. The review of the literature and experimental results performed by the author has shown that current design and analysis procedures are not suitable for predictions of the response of sandwich structures for concentrated loading. To investigate the response of sandwich structures to concentrated loading, experiments were carried out on beam specimens with polyurethane foam core with various densities and thickness, and faces made of AS4/3501-6 carbon/epoxy fiber composite of various thickness under three point loading, which gives a concentrated loading. Overall deformation was measured, along with strains from both surface and embedded gages. Additionally, compression tests and torsion tests have been done for the polyurethane foam used as core in the sandwich beam to characterize its yield properties. Many theories, including classical theory, first order shear deformation theory, higher order theory, elasticity and FE analysis, were compared with the three-point bending experiments. A two-dimensional elasticity solution, which is suitable for sandwich beams under simply support boundary conditions, was used to obtain the strain/stress distribution, failure prediction and optimization work. The common failure modes of sandwich beams have been observed, including core failure in compression and shear failure in core, delamination, and fiber failure in the face. The failure modes can be predicted for sandwich beams under localized loading using elasticity theory and the failure is controlled by a failure mode with the lowest load. An algorithm developed by Swanson and Kim was used to predict the optimum design of sandwich structures for strength to weight under concentrated loading and compared with experimental yield or

  9. [Development of an antigen 'sandwich' enzyme immunoassay for the detection of antibodies against HIV-2 by using a biotinylated synthetic peptide of gp36 protein].

    Science.gov (United States)

    Delahanty-Fernández, Aurora; Bequer-Ariza, Dunia Clara; Hernández-Marín, Milenen; Zulueta-Rodríguez, Orlando; Pozo-Peña, Lilliam; Hernández-Spengler, Idialis; Ramos-Martínez, Grisell; Valdespino-Díaz, Marcos Antonio; Ventura-Paz, Julio

    2015-01-01

    Among the several existing methods for the detection of antibodies to HIV, the 'sandwich' ELISA is currently the most used. This study aims to assess a biotinylated monomeric synthetic peptide of the glycoprotein trans-membrane gp36 from HIV-2, in a sandwich assay, for the detection of antibodies against this HIV-2 protein. To perform the assay, plates coated with recombinant protein gp36 at 0.5μg/mL and synthetic peptide gp36(5) at 1μg/mL were used. The concentration of the biotinylated synthetic peptide (gp36(5)-B) used was 0.1μg/mL prepared with a Tris-BSA-NaCl buffer solution and the Streptavidin- Alkaline Phosphatase conjugate diluted 1:30000 prepared with a PBS-Sucrose-BSA solution. Positive serum samples to antibodies against HIV-1 and HIV-2 viruses (88 and 34, respectively) were tested, with 483 negative samples from blood donors and 96 serum samples to assess the analytical specificity. All the samples were tested using the UMELISA HIV 1+2 RECOMBINANT assay, and all positives were confirmed using a DAHIV-BLOT assay. Thirty four samples with antibodies against HIV-2 were assessed as positive for both coating variants. The highest specificity was obtained with the variant using the synthetic peptide gp36(5) in its coating. The antigen 'sandwich' assay developed by using gp36(5)-B enables the detection of antibodies against gp36 protein of HIV-2. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  10. Evaluating concentration estimation errors in ELISA microarray experiments

    Directory of Open Access Journals (Sweden)

    Anderson Kevin K

    2005-01-01

    Full Text Available Abstract Background Enzyme-linked immunosorbent assay (ELISA is a standard immunoassay to estimate a protein's concentration in a sample. Deploying ELISA in a microarray format permits simultaneous estimation of the concentrations of numerous proteins in a small sample. These estimates, however, are uncertain due to processing error and biological variability. Evaluating estimation error is critical to interpreting biological significance and improving the ELISA microarray process. Estimation error evaluation must be automated to realize a reliable high-throughput ELISA microarray system. In this paper, we present a statistical method based on propagation of error to evaluate concentration estimation errors in the ELISA microarray process. Although propagation of error is central to this method and the focus of this paper, it is most effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization, and statistical diagnostics when evaluating ELISA microarray concentration estimation errors. Results We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of concentration estimation errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error. We summarize the results with a simple, three-panel diagnostic visualization featuring a scatterplot of the standard data with logistic standard curve and 95% confidence intervals, an annotated histogram of sample measurements, and a plot of the 95% concentration coefficient of variation, or relative error, as a function of concentration. Conclusions This statistical method should be of value in the rapid evaluation and quality control of high

  11. Evaluating concentration estimation errors in ELISA microarray experiments.

    Science.gov (United States)

    Daly, Don Simone; White, Amanda M; Varnum, Susan M; Anderson, Kevin K; Zangar, Richard C

    2005-01-26

    Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to estimate a protein's concentration in a sample. Deploying ELISA in a microarray format permits simultaneous estimation of the concentrations of numerous proteins in a small sample. These estimates, however, are uncertain due to processing error and biological variability. Evaluating estimation error is critical to interpreting biological significance and improving the ELISA microarray process. Estimation error evaluation must be automated to realize a reliable high-throughput ELISA microarray system. In this paper, we present a statistical method based on propagation of error to evaluate concentration estimation errors in the ELISA microarray process. Although propagation of error is central to this method and the focus of this paper, it is most effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization, and statistical diagnostics when evaluating ELISA microarray concentration estimation errors. We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of concentration estimation errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error. We summarize the results with a simple, three-panel diagnostic visualization featuring a scatterplot of the standard data with logistic standard curve and 95% confidence intervals, an annotated histogram of sample measurements, and a plot of the 95% concentration coefficient of variation, or relative error, as a function of concentration. This statistical method should be of value in the rapid evaluation and quality control of high-throughput ELISA microarray analyses. Applying propagation of error to

  12. Photocatalytic perfermance of sandwich-like BiVO{sub 4} sheets by microwave assisted synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Suqin, E-mail: liusuqin888@126.com [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Hubei Key Laboratory of Low Dimensional Optoelectronic Materials and Devices, Xiangyang 441053 (China); Tang, Huiling; Zhou, Huan [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Dai, Gaopeng, E-mail: dgp2000@126.com [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Wang, Wanqiang [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China)

    2017-01-01

    Graphical abstract: Sandwich-like BiVO{sub 4} sheets were successfully synthesized via a facile microwave-assisted method. The as-prepared samples exhibit a high activity for the degradation of methyl orange under visible light irradiation. - Highlights: • Sandwich-like BiVO{sub 4} sheets were synthesized by a facile microwave-assisted method. • The presence of PEG-10000 plays a critical role in the formation of BiVO{sub 4} sheets. • Ostwald ripening is the primary driving force for the formation of sandwich-like BiVO{sub 4}. • The sandwich-like BiVO{sub 4} sheets exhibit a high visible-light photocatalytic activity. - Abstract: Sandwich-like BiVO{sub 4} sheets were successfully synthesized in an aqueous solution containing bismuth nitrate, ammonium metavanadate and polyethylene glycol with a molecular weight of 10,000 (PEG-10000) using a facile microwave-assisted method. The as-prepared samples were characterized by scanning electron microscopy, N{sub 2} adsorption-desorption, X-ray diffraction, X-ray photoelectron spectroscopy (XPS), and UV–vis diffuse reflectance spectroscopy. The results show that the presence of PEG-10000 plays a critical role in the formation of BiVO{sub 4} sheets, and Ostwald ripening is the primary driving force for the formation of sandwich-like structures. The sandwich-like BiVO{sub 4} sheets exhibit a high activity for the degradation of methyl orange under visible light irradiation (λ ≥ 420 nm). The enhancement of photocatalytic activity of sandwich-like BiVO{sub 4} sheets can be attributed to its large surface area over the irregular BiVO{sub 4} particles.

  13. Adaptive Focused Acoustics (AFA) Improves the Performance of Microtiter Plate ELISAs.

    Science.gov (United States)

    Green, David J; Rudd, Edwin A; Laugharn, James A

    2014-08-01

    We investigated the use of Adaptive Focused Acoustics (AFA) technology to improve the performance of microtiter plate enzyme-linked immunosorbent assays (ELISAs). Experiments were performed with commercially available AFA instrumentation and off-the-shelf 96-well microtiter plate sandwich ELISAs. AFA was applied over a range of acoustic energies, temperatures, and durations to the antigen/antibody binding step of an ELISA for measuring HIV-1 p24 in tissue culture samples. AFA-mediated antigen/antibody binding was enhanced up to 2-fold over passive binding at comparable temperatures and was superior or comparable at low temperature (8-10 °C) to passive binding at 37 °C. Lower nonspecific binding (NSB), lower inter- and intra-assay coefficients of variation (CVs), higher Z' factors, and lower limits of detection (LODs) were measured in AFA-mediated assays compared with conventional passive binding. In a more limited study, AFA enhancement of antigen/antibody binding and lower NSB was measured in an ELISA for measuring IGFBP-3 in human plasma. We conclude from this study that application of AFA to antigen/antibody binding steps in microtiter plate ELISAs can enhance key assay performance parameters, particularly Z' factors and LODs. These features render AFA-mediated binding assays potentially more useful in applications such as high-throughput screening and in vitro diagnostics than assays processed with conventional passive antigen/antibody binding steps. © 2014 Society for Laboratory Automation and Screening.

  14. Validation of ELISA for the detection of African horse sickness virus antigens and antibodies.

    Science.gov (United States)

    Rubio, C; Cubillo, M A; Hooghuis, H; Sanchez-Vizcaino, J M; Diaz-Laviada, M; Plateau, E; Zientara, S; Crucière, C; Hamblin, C

    1998-01-01

    The mortality rate in susceptible populations of horses during an epizootic of African horse sickness (AHS) may be in excess of 90%. Rapid and reliable assays are therefore essential for the confirmation of clinical diagnoses and to enable control strategies to be implemented without undue delay. One of the major objectives of a recent European Union funded project was the validation of newly developed diagnostic assays which are rapid, sensitive, highly reproducible and inexpensive, for the detection of African horse sickness virus (AHSV) antigens and antibodies. The Laboratorio de Sanidad y Produccion Animal (LSPA) in Algete, Spain was charged with the responsibility of co-ordinating and supplying samples of viruses and antisera to the participating laboratories in Spain, France and the United Kingdom. The panels comprised 76 antigen samples for assay by indirect sandwich ELISAs and 53 serum samples for antibody detection by either indirect or competitive ELISAs. Results generated by ELISA for each laboratory were analysed in LSPA in terms of their relative sensitivities and specificities. There was a good agreement between the ELISAs used for either antigen or antibody detection. The participating groups agreed that any field sample giving a doubtful result would always be retested by ELISA and an alternative assay.

  15. Vibroacoustic optimization of anti-tetrachiral and auxetic hexagonal sandwich panels with gradient geometry

    Science.gov (United States)

    Ranjbar, Mostafa; Boldrin, Luca; Scarpa, Fabrizio; Neild, Simon; Patsias, Sophoclis

    2016-05-01

    The work describes the vibroacoustic behavior of anti-tetrachiral and auxetic hexagonal gradient sandwich panels using homogenized finite element models to determine the mechanical properties of the auxetic structures, the natural frequencies and radiated sound power level of sandwich panels made by the auxetic cores. The mechanical properties and the vibroacoustic behavior of auxetic hexagonal sandwich panels are investigated as a benchmark. The radiated sound power level of the structure over the frequency range of 0-1000 Hz is minimized by modifying the core geometry of the gradient auxetic sandwich panels. Several excitation cases are considered. First-order and random optimization methods are used for the minimization of radiated sound power level of the structures. The results of this study present significant insights into the design of auxetic structures with respect to their vibroacoustical properties.

  16. Novel sandwich structure adsorptive membranes for removal of 4-nitrotoluene from water

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yuexin [College of Chemistry, Beijing Normal University, Beijing 100875 (China); School of Pharmacy, North China University of Science and Technology, Tangshan 063000 (China); Jia, Zhiqian, E-mail: zhqjia@bnu.edu.cn [College of Chemistry, Beijing Normal University, Beijing 100875 (China)

    2016-11-05

    Highlights: • Novel sandwich PES-SPES/PS-PDVB/PTFE adsorptive membranes were prepared. • The removal efficiency for 4-nitrotoluene is greater than 95% after five recycles. • The membrane showed higher adsorption capacity than that of mixed matrix membrane. - Abstract: Novel sandwich PES-SPES/PS-PDVB/PTFE adsorptive membranes were prepared by a filtration/immersion precipitation method and employed for the removal of 4-nitrotoluene from water. The static adsorption thermodynamics, kinetics, dynamic adsorption/desorption and membrane reusability were investigated. The results showed that the Freundlich model describes the adsorption isotherm satisfactorily. With increased PS-PDVB content, the maximum static adsorption capacity, partition coefficient, apparent adsorption rate constant, and dynamic adsorption capacity all significantly increased. The sandwich membranes showed much higher removal efficiency and adsorption capacity than those of mixed matrix membranes. With respect to dynamics adsorption/desorption, the sandwich membranes exhibited excellent reusability, with a removal efficiency greater than 95% even after five recycles.

  17. Stress Distribution on Sandwich Structure with Triangular Grid Cores Suffered from Bending Load

    Directory of Open Access Journals (Sweden)

    Cui Xu

    2015-01-01

    Full Text Available Triangular grid reinforced by carbon fiber/epoxy (CF/EP was designed and manufactured. The sandwich structure was prepared by gluing the core and composite skins. The mechanical properties of the sandwich structure were investigated by the finite element analysis (FEA and three-point bending methods. The calculated bending stiffness and core shear stress were compared to the characteristics of a honeycomb sandwich structure. The results indicated that the triangular core ultimately failed under a bending load of 11000 N; the principal stress concentration was located at the loading region; and the cracks occurred on the interface top skin and triangular core. In addition, the ultimate stress bearing of the sandwich structure was 8828 N. The experimental results showed that the carbon fiber reinforced triangular grid was much stiffer and stronger than the honeycomb structure.

  18. Applications of thin-film sandwich crystallization platforms

    Energy Technology Data Exchange (ETDEWEB)

    Axford, Danny, E-mail: danny.axford@diamond.ac.uk; Aller, Pierre; Sanchez-Weatherby, Juan; Sandy, James [Diamond Light Source, Harwell Oxford, Didcot OX11 0DE (United Kingdom)

    2016-03-24

    Crystallization via sandwiches of thin polymer films is presented and discussed. Examples are shown of protein crystallization in, and data collection from, solutions sandwiched between thin polymer films using vapour-diffusion and batch methods. The crystallization platform is optimal for both visualization and in situ data collection, with the need for traditional harvesting being eliminated. In wells constructed from the thinnest plastic and with a minimum of aqueous liquid, flash-cooling to 100 K is possible without significant ice formation and without any degradation in crystal quality. The approach is simple; it utilizes low-cost consumables but yields high-quality data with minimal sample intervention and, with the very low levels of background X-ray scatter that are observed, is optimal for microcrystals.

  19. Monoclonal antibody-based serological methods for detection of Cucumber green mottle mosaic virus

    Directory of Open Access Journals (Sweden)

    Qian Yajuan

    2011-05-01

    Full Text Available Abstract Background Cucumber green mottle mosaic virus (CGMMV, a member of the genus Tobamovirus, can be transmitted by seeds and infects many cucurbit species, causing serious yield losses in cucumber and watermelon plants. In this paper, five serological methods including antigen-coated plate enzyme-linked immunosorbent assay (ACP-ELISA, triple antibody sandwich enzyme-linked immunosorbent assay (TAS-ELISA, Dot-immunobinding assay (DBIA, direct tissue blot immunoassay (DTBIA and immunocapture reverse transcriptase polymerase chain reaction (IC-RT-PCR were described for detection and diagnosis of CGMMV. Results Using the purified CGMMV particles as immunogens, six murine monoclonal antibodies (MAbs were produced. Five serological methods were established using the MAb 4H1 and detection sensitivity was compared using purified preparations and infected-plant tissue extracts. The detection sensitivity of ACP-ELISA was 0.16 ng of purified CGMMV, whereas TAS-ELISA was more sensitive than ACP-ELISA with a minimum detection of 0.04 ng of purified CGMMV. The sensitivities of TAS-ELISA and DBIA were similar for detecting CGMMV in infected-plant tissue extracts, and were four times higher than ACP-ELISA. The IC-RT-PCR was the most sensitive method, which could detect as little as 0.1 pg of purified virus. The detection sensitivity of IC-RT-PCR for CGMMV-infected plant tissues was about 400 times higher than that of TAS-ELISA and DBIA. Conclusions The established ACP-ELISA, TAS-ELISA, DBIA and DTBIA are suitable for routine CGMMV detection of large-scale samples in the field survey, while IC-RT-PCR is more sensitive and suitable for acquiring information about the viral genome.

  20. ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection.

    Science.gov (United States)

    Sun, Steven; Yang, Minghui; Kostov, Yordan; Rasooly, Avraham

    2010-08-21

    A miniature 96 sample ELISA-lab-on-a-chip (ELISA-LOC) was designed, fabricated, and tested for immunological detection of Staphylococcal Enterotoxin B (SEB). The chip integrates a simple microfluidics system into a miniature ninety-six sample plate, allowing the user to carry out an immunological assay without a laboratory. Assay reagents are delivered into the assay plate without the need for separate devices commonly used in immunoassays. The ELISA-LOC was constructed using Laminated Object Manufacturing (LOM) technology to assemble six layers with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser. The ELISA-LOC has three main functional elements: reagent loading fluidics, assay and detection wells, and reagent removal fluidics, a simple "surface tension" valve used to control the flow. To enhance assay sensitivity and to perform the assay without a lab, ELISA-LOC detection combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected SEB at concentrations as low as 0.1 ng ml(-1), which is similar to the reported sensitivity of conventional ELISA. The fluidics system can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without a laboratory.

  1. Comparative study of circulating immune complexes quantity detection by three assays--CIF-ELISA, C1q-ELISA and anti-C3 ELISA.

    Science.gov (United States)

    Stanilova, S A; Slavov, E S

    2001-07-01

    The assessment of the soluble immune complexes (IC) in human sera is traditionally performed by the C1q binding assay. In the present study, a novel method for the quantity of immune complexes was reported. The methodology was based on measuring their deposition on solid-phase C3 binding glycoprotein (CIF), using an enzyme-linked immunosorbent assay. We also used ELISA that employed anti-C3 antibodies to determined the quantity of immune complexes. The three assays were evaluated for their performance characteristics on the same specially prepared samples: 55 normal sera, 99 sera from RA, 88 sera from SLE, and 27 sera from PSS. The results were compared by reference to a common standard-heat aggregated IgG that possesses many activities of immune complexes. Three of the tests used displayed almost the same specificity (over 95%), while their relative sensitivity varied depending on the disease sera tested. The sensitivity of the assays used was recorded highest for C1q ELISA-28.97% of positive sera, followed by CIF-ELISA-19.63% and lowest for anti-C3 ELISA-17.29%. A well-expressed correlation was found between CIF-ELISA and anti-C3 ELISA data (r=0.42), and a week correlation was noted when comparing CIF-ELISA and C1q ELISA IC levels detected (r=0.28). When the correlation coefficients were calculated individually for each disease category, they were clearly different, and that reflected indirectly in different sensitivities of the test for various disease categories. We also found that the results from the simultaneous performance of the tests demonstrated low percentage positive results when three or two assays were used. This is most probably due to the different assay abilities to detect IC with different sizes and composition, which shows that a small part of IC in the tested sera can be detected simultaneously by more than one assay. On the basis of the results obtained, we concluded that optimal screening for IC could be achieved by parallel application of

  2. Sandwich Structure Based On Corrugated-Core: A Review

    Directory of Open Access Journals (Sweden)

    Zaid N. Z. M.

    2016-01-01

    Full Text Available Sandwich structures are commonly based on polymeric foam and honeycomb core material, for use in lightweight applications such as fuselage in aero plane, hull in marine construction and others. A review of sandwich structure based on corrugated-core is proposed and presented in this paper. Firstly, this paper aims to provide a means of comparing available sandwich structure in industries. Secondly, this paper aims to provide sandwich structure with corrugated-core for future research development efforts in field of sandwich construction. This paper starts with introduction of composite material such as sandwich structure, the advantages of sandwich structure was shown. After that these papers provide the structure of sandwich structure which includes the two faces and the cores. Furthermore, sandwich structure with different cores, which is honeycomb, foam core and corrugated core are discussed. At the end, the paper discussed more on corrugated-core for future research development.

  3. Impact properties of aluminium - glass fiber reinforced plastics sandwich panels

    Directory of Open Access Journals (Sweden)

    Mathivanan Periasamy

    2012-06-01

    Full Text Available Aluminium - glass fiber reinforced plastics (GFRP sandwich panels are hybrid laminates consisting of GFRP bonded with thin aluminum sheets on either side. Such sandwich materials are increasingly used in airplane and automobile structures. Laminates with varying aluminium thickness fractions, fiber volume fractions and orientation in the layers of GFRP were fabricated by hand lay up method and evaluated for their impact performance by conducting drop weight tests under low velocity impacts. The impact energy required for initiating a crack in the outer aluminium layer as well as the energy required for perforation was recorded. The impact load-time history was also recorded to understand the failure behavior. The damage depth and the damage area were measured to evaluate the impact resistance. Optical photography and scanning electron micrographs were taken to visualize the crack and the damage zone. The bidirectional cross-ply hybrid laminate (CPHL has been found to exhibit better impact performance and damage resistance than the unidirectional hybrid laminate (UDHL. Increase in aluminium thickness fraction (Al tf and fiber volume fraction (Vf resulted in an increase in the impact energy required for cracking and perforation. On an overall basis, the sandwich panels exhibited better impact performance than the monolithic aluminium.

  4. Thermo-Fluidic Comparison between Sandwich Panels with Tetrahedral Lattice Cores Fabricated by Casting and Metal Sheet Folding

    Directory of Open Access Journals (Sweden)

    Xiaoqing Zhang

    2017-07-01

    Full Text Available This numerical study compares single-phase forced convective heat transfer between two sandwich panels with tetrahedral metallic lattice cores separately fabricated by investment casting and the more cost-effective metal sheet folding method. The numerical model is validated against available experimental data. For a given Reynolds number and core porosity, the results reveal that the brazed sandwich outperforms the casted sandwich, exhibiting a 13% to 16% higher Nusselt number. Bigger vertexes and more evident blockage of mainstream by the ligaments are found to intensify the horseshoe vortex and the counter-rotating vortex pair upstream and downstream of each vertex. Relative to the casted sandwich panel, therefore, endwall heat transfer is enhanced by 22% to 27%, while similar heat transfer is achieved on the ligaments. It is also found that, for a given Reynolds number, the brazed sandwich induces a 1.6 to 1.7 times higher pressure drop relative to the casted sandwich due to more severe flow separation caused by the sharp edges of the rectangular ligaments. Finally, for a given pumping power, both sandwiches provide a similar heat transfer performance. Given that the brazed sandwich is more cost-effective and easier to fabricate than the casted one, the former may be superior from an engineering application point of view.

  5. ELISA reagent coverage evaluation by affinity purification tandem mass spectrometry.

    Science.gov (United States)

    Henry, Scott M; Sutlief, Elissa; Salas-Solano, Oscar; Valliere-Douglass, John

    2017-10-01

    Host cell proteins (HCPs) must be adequately removed from recombinant therapeutics by downstream processing to ensure patient safety, product quality, and regulatory compliance. HCP process clearance is typically monitored by enzyme-linked immunosorbent assay (ELISA) using a polyclonal reagent. Recently, mass spectrometry (MS) has been used to identify specific HCP process impurities and monitor their clearance. Despite this capability, ELISA remains the preferred analytical approach due to its simplicity and throughput. There are, however, inherent difficulties reconciling the protein-centric results of MS characterization with ELISA, or providing assurance that ELISA has acceptable coverage against all process-specific HCP impurities that could pose safety or efficacy risks. Here, we describe efficient determination of ELISA reagent coverage by proteomic analysis following affinity purification with a polyclonal anti-HCP reagent (AP-MS). The resulting HCP identifications can be compared with the actual downstream process impurities for a given process to enable a highly focused assessment of ELISA reagent suitability. We illustrate the utility of this approach by performing coverage evaluation of an anti-HCP polyclonal against both an HCP immunogen and the downstream HCP impurities identified in a therapeutic monoclonal antibody after Protein A purification. The overall goal is to strategically implement affinity-based mass spectrometry as part of a holistic framework for evaluating HCP process clearance, ELISA reagent coverage, and process clearance risks. We envision coverage analysis by AP-MS will further enable a framework for HCP impurity analysis driven by characterization of actual product-specific process impurities, complimenting analytical methods centered on consideration of the total host cell proteome.

  6. Failure Predictions of Out-of-Autoclave Sandwich Joints with Delaminations Under Flexure Loads

    Science.gov (United States)

    Nordendale, Nikolas A.; Goyal, Vinay K.; Lundgren, Eric C.; Patel, Dhruv N.; Farrokh, Babak; Jones, Justin; Fischetti, Grace; Segal, Kenneth N.

    2015-01-01

    An analysis and a test program was conducted to investigate the damage tolerance of composite sandwich joints. The joints contained a single circular delamination between the face-sheet and the doubler. The coupons were fabricated through out-of-autoclave (OOA) processes, a technology NASA is investigating for joining large composite sections. The four-point bend flexure test was used to induce compression loading into the side of the joint where the delamination was placed. The compression side was chosen since it tends to be one of the most critical loads in launch vehicles. Autoclave cure was used to manufacture the composite sandwich sections, while the doubler was co-bonded onto the sandwich face-sheet using an OOA process after sandwich panels were cured. A building block approach was adopted to characterize the mechanical properties of the joint material, including the fracture toughness between the doubler and face-sheet. Twelve four-point-bend samples were tested, six in the sandwich core ribbon orientation and six in sandwich core cross-ribbon direction. Analysis predicted failure initiation and propagation at the pre-delaminated location, consistent with experimental observations. A building block approach using fracture analyses methods predicted failure loads in close agreement with tests. This investigation demonstrated a small strength reduction due to a flaw of significant size compared to the width of the sample. Therefore, concerns of bonding an OOA material to an in-autoclave material was mitigated for the geometries, materials, and load configurations considered.

  7. An Analysis of Nondestructive Evaluation Techniques for Polymer Matrix Composite Sandwich Materials

    Science.gov (United States)

    Cosgriff, Laura M.; Roberts, Gary D.; Binienda, Wieslaw K.; Zheng, Diahua; Averbeck, Timothy; Roth, Donald J.; Jeanneau, Philippe

    2006-01-01

    Structural sandwich materials composed of triaxially braided polymer matrix composite material face sheets sandwiching a foam core are being utilized for applications including aerospace components and recreational equipment. Since full scale components are being made from these sandwich materials, it is necessary to develop proper inspection practices for their manufacture and in-field use. Specifically, nondestructive evaluation (NDE) techniques need to be investigated for analysis of components made from these materials. Hockey blades made from sandwich materials and a flat sandwich sample were examined with multiple NDE techniques including thermographic, radiographic, and shearographic methods to investigate damage induced in the blades and flat panel components. Hockey blades used during actual play and a flat polymer matrix composite sandwich sample with damage inserted into the foam core were investigated with each technique. NDE images from the samples were presented and discussed. Structural elements within each blade were observed with radiographic imaging. Damaged regions and some structural elements of the hockey blades were identified with thermographic imaging. Structural elements, damaged regions, and other material variations were detected in the hockey blades with shearography. Each technique s advantages and disadvantages were considered in making recommendations for inspection of components made from these types of materials.

  8. Development and evaluation of a Luminex multiplex serology assay to detect antibodies to bovine herpes virus 1, parainfluenza 3 virus, bovine viral diarrhoea virus, and bovine respiratory syncytial virus, with comparison to existing ELISA detection methods.

    Science.gov (United States)

    Anderson, Steve; Wakeley, Phil; Wibberley, Guy; Webster, Kath; Sawyer, Jason

    2011-03-07

    Detection of circulating antibodies to bovine herpes virus 1 (BHV-1), parainfluenza 3 virus (PI3V), bovine viral diarrhoea virus (BVDV) and bovine respiratory syncytial virus (BRSV) using ELISA is widely used for veterinary diagnostics and surveillance. In this paper, the potential of a multiplex serology test based on Luminex technology, where all antibodies are simultaneously detected in a single assay was investigated. The performance of "in-house" separate ELISAs which use relatively crude lysates of cultured virus as capture antigens, was compared to the multiplex assay where the same antigens were covalently bound to the fluorescent beads used in the Luminex platform. A panel of field serum samples was tested by the multiplex assay in parallel with the separate routine ELISAs to provide a comparison between tests. The BHV-1 and PI3V components of the multiplex test showed similar sensitivities and specificities to the separate "in-house" ELISAs. The performance of the BVDV and BRSV components was less successful and was attributed to relatively low signal strength for these antigens, leading to higher assay variability and a reduced ability to distinguish positive and negative samples compared to the "in-house" ELISAs. The results illustrated that antigens commonly used successfully in ELISAs cannot always be transferred for use in alternative assay systems. The use of recombinant BVDV E2 protein was investigated and was shown to lead to an appreciable increase in signal strength compared to the use of crude BVDV antigen in the Luminex system. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  9. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  10. Experimental study of acoustical characteristics of honeycomb sandwich structures

    Science.gov (United States)

    Peters, Portia Renee

    Loss factor measurements were performed on sandwich panels to determine the effects of different skin and core materials on the acoustical properties. Results revealed inserting a viscoelastic material in the core's mid-plane resulted in the highest loss factor. Panels constructed with carbon-fiber skins exhibited larger loss factors than glass-fiber skins. Panels designed to achieve subsonic wave speed did not show a significant increase in loss factor above the coincidence frequency. The para-aramid core had a larger loss factor value than the meta-aramid core. Acoustic absorption coefficients were measured for honeycomb sandwiches designed to incorporate multiple sound-absorbing devices, including Helmholtz resonators and porous absorbers. The structures consisted of conventional honeycomb cores filled with closed-cell polyurethane foams of various densities and covered with perforated composite facesheets. Honeycomb cores filled with higher density foam resulted in higher absorption coefficients over the frequency range of 50 -- 1250 Hz. However, this trend was not observed at frequencies greater than 1250 Hz, where the honeycomb filled with the highest density foam yielded the lowest absorption coefficient among samples with foam-filled cores. The energy-recycling semi-active vibration suppression method (ERSA) was employed to determine the relationship between vibration suppression and acoustic damping for a honeycomb sandwich panel. Results indicated the ERSA method simultaneously reduced the sound transmitted through the panel and the panel vibration. The largest reduction in sound transmitted through the panel was 14.3% when the vibrations of the panel were reduced by 7.3%. The influence of different design parameters, such as core density, core material, and cell size on wave speeds of honeycomb sandwich structures was experimentally analyzed. Bending and shear wave speeds were measured and related to the transmission loss performance for various material

  11. Vibro-acoustics of lightweight sandwich structures

    CERN Document Server

    Lu, Tianjian

    2014-01-01

    Vibro-Acoustics of Lightweight Sandwich Structures introduces the study of the coupled vibration and acoustic behavior of lightweight sandwich structures in response to harmonic force and sound pressure. This book focuses on the theoretical modeling and experimental investigation of lightweight sandwich structures in order to provide a predictive framework for vibro-acoustic characteristics of typical engineering structures. Furthermore, by developing solution tools, it concentrates on the influence of key systematic parameters leading to effective guidance for optimal structure design toward lightweight, high-stiffness and superior sound insulation capability. This book is intended for researchers, scientists, engineers and graduate students in mechanical engineering especially in structural mechanics, mechanics and acoustics. Fengxian Xin and Tianjian Lu both work at the School of Aerospace, Xi’an Jiaotong University.

  12. Serodiagnosis of human leptospirosis by Enzyme Linked Immunosorbent Assay (ELISA

    Directory of Open Access Journals (Sweden)

    Waleed Al-orry

    2017-01-01

    Full Text Available Background Leptospirosis is a zoonotic bacterial disease that affects humans and animals. The disease occurs by contact direct or indirect with the urine of infected animal and common among agriculture workers, garbage collectors, sewage works, forestry and animal slaughtering. The disease also spreads in tropical regions where the conditions are favourable for leptospires. Aims The purpose of this study is to determine human leptospirosis among suspected cases by ELISA IgM (a retrospective study on 50 cases from 2004 to 2010. Methods Sera from patients had fever and jaundice suspected clinically from leptospirosis, were referred to the National Institute of Hygiene in Rabat, Morocco. ELISA IgM and SAT were used for the diagnosis. Results While 33 serums were positive by Slide Agglutination Test (SAT, thirty one serums were positive by ELISA IgM. The sensitivity was 62 per cent and 66 per cent in ELISA and SAT respectively. Conclusion ELISA IgM and SAT seem to be useful for human leptospirosis; they can detect the disease from the 5th day of the illness. They are easy, inexpensive and useful for developing countries and less equipped laboratories. However, if the first sera was negative, the second sera should obtained in the second week, or PCR used in combination with serological tests if it is available.

  13. Nonsmooth Recursive Identification of Sandwich Systems with Backlash-Like Hysteresis

    Directory of Open Access Journals (Sweden)

    Ruili Dong

    2012-01-01

    Full Text Available A recursive gradient identification algorithm based on the bundle method for sandwich systems with backlash-like hysteresis is presented in this paper. In this method, a dynamic parameter estimation scheme based on a subgradient is developed to handle the nonsmooth problem caused by the backlash embedded in the system. The search direction of the algorithm is estimated based on the so-called bundle method. Then, the convergence of the algorithm is discussed. After that, simulation results on a nonsmooth sandwich system are presented to validate the proposed estimation algorithm. Finally, the application of the proposed method to an X-Y moving positioning stage is illustrated.

  14. AA, sandwich line with magnetic horn

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The magnetic horn, focusing the antiprotons emanating from the target, was affixed to a sandwich line through which the 150 kA pulses were supplied. Expecting to have to change from time to time the fragile horn (inner conductor only 0.7 mm thick), the assembly was designed for quick exchange. At the lower end of the sandwich line we see the connectors for the high-current cables, at the upper end the magnet horn. It has just been lifted from the V-supports which held it aligned downstream of the target. Continue with 8010293.

  15. Ultra-Light Asymmetric Photovoltaic Sandwich Structures

    OpenAIRE

    Rion, J.; Leterrier, Y.; Månson, J.-A. E.; Blairon, Jean-Marie

    2009-01-01

    This work evaluated the possibility of using silicon solar cells as load-carrying elements in composite sandwich structures. Such an ultra-light multifunctional structure is a new concept enabling weight, and thus energy, to be saved in high-tech applications such as solar cars, solar planes or satellites. Composite sandwich structures with a weight of not, vert, similar800 g/m2 were developed, based on one 140 μm thick skin made of 0/90° carbon fiber-reinforced plastic (CFRP), one skin made ...

  16. Influence of phosphatidylethanolamine concentration and composition on the detection of antiphosphatidylethanolamine antibodies by ELISA

    OpenAIRE

    Ke, Ke; Strango, Zachariah I.; Harper, Paul E.; Zhao, Ming

    2016-01-01

    Accumulating evidence supports a positive correlation between the presence of antiphosphatidylethanolamine (aPE) autoantibodies and clinical symptoms of antiphospholipid syndroms (APS). However, there lacks a standardized ELISA-based method for detecting aPE. The current study was to investigate the dependence of aPE ELISA on lipid concentration and composition of PE antigens. Our data indicated that there are different optimal PE concentrations for conducting ELISA assays for cofactor depend...

  17. Designing of enzyme linked immunosorbent assay (ELISA) kit for ...

    African Journals Online (AJOL)

    The sensitivity of microscopic examination of fecal samples to recognize Giardia parasites is low. In the methods based on antigen scanning of parasites such as enzyme linked immunosorbent assay (ELISA), copro-antigens of parasite will be traced and diagnosed even if the live parasite is absent in the fecal samples.

  18. Detection of Fasciola gigantica antibodies using Pourquier ELISA kit ...

    African Journals Online (AJOL)

    An indirect ELISA analysis method was employed using the protocol designed by the manufacturer. The validity of the test for each plate was carried out. Results confirmed the presence of Fasciola gigantica antibodies: 162 positive cases out of the 225 cattle sampled, which gave an overall prevalence of 72%. Antibodies ...

  19. Serial follow-up of repeat voluntary blood donors reactive for anti-HCV ELISA

    Directory of Open Access Journals (Sweden)

    Choudhury N

    2011-01-01

    Full Text Available Background : Voluntary non-remunerated repeat blood donors are perceived to be safer than the first time blood donors. This study was planned for follow-up of previous hepatitis C virus (HCV test results of anti-HCV enzyme-linked immunosorbent assay (ELISA reactive repeat blood donors. The aim was to suggest a protocol for re-entry of the blood donors who are confirmed HCV negative by nucleic acid test (NAT and recombinant immunoblot assay (RIBA. A group of repeat voluntary donors were followed retrospectively who became reactive on a cross sectional study and showed HCV reactivity while donating blood regularly. Material and Methods: A total of 51,023 voluntary non remunerated blood donors were screened for anti-HCV ELISA routinely. If anybody showed positivity, they were tested by two ELISA kits (screening and confirmatory and then confirmed infection status by NAT and or RIBA. The previous HCV test results of repeat donors reactive by anti-HCV ELISA were looked back from the records. Data of donors who were repeat reactive with single ELISA kit (in the present study were analyzed separately from those reactive with two ELISA kits (in the present study. Results: In this study, 140 (0.27% donors who were reactive by anti HCV ELISA were included. Out of them, 35 were repeat voluntary donors and 16 (11.43% were reactive with single ELISA kit. All 16 donors were reactive by single ELISA kit occasionally in previous donations. Their present ELISA positive donations were negative for HCV NAT and RIBA. A total of 19 (13.57% donors were reactive with two ELISA kits. In their previous donations, the donors who were reactive even once with two ELISA kits were consistently reactive by the same two ELISA kits in their next donations also. Conclusion: Donor sample reactive by only single ELISA kit may not be considered as infectious for disposal as they were negative by NAT and or RIBA. One time ELISA positivity was found probably due to ELISA kit

  20. Overall Buckling and Wringkling of Debonded Sandwich Beams: Finite Element and Experimental Results

    Directory of Open Access Journals (Sweden)

    Bambang K. Hadi

    2006-05-01

    Full Text Available Overall buckling and wrinkling of debonded sandwich beams under compressive loads were analyzed by both finite element and experimental methods. In the finite element method, a quarter and a half models of the specimens were analyzed. It shows that a quarter model is not adequate to analyze buckling of debonded sandwich beams, since it will disregard overall buckling mode that may occur in sandwich beams having compressive loads. At least a half model should be used to analyze buckling of sandwich beams. A finite element program UNA was used extensively to analyze the buckling loads. Experimental buckling of sandwich beams was carried out using a compression testing machine. Two LVDTs were used to measure deflections of the specimen during experimental loading. The loads were measured using load cells available in the machine. Specimens having core thickness of 45 and 75 mm were tested to represent overall and wrinkling modes respectively. The delamination lengths were 20, 60 and 80 mm, which represent 10, 30 and 40% of the beam length. The results show that the differences between experimental and finite element methods were less than 10%. Both overall buckling and wrinkling modes were shown in these specimens.

  1. AA, sandwich line with magnetic horn

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Continuation from 8010293: Finally, the sandwich line with the horn is placed on the ground, for the horn to be inspected and, if needed, exchanged for a new one. The whole procedure was trained with several members of the AA team, for quick and safe handling, and to share the radiation dose amongst them.

  2. Compressive properties of sandwiches with functionally graded ...

    Indian Academy of Sciences (India)

    The compressive behaviour of a new class of sandwich composite made up of jute fiber reinforced epoxy skins and piece-wise linear fly ash reinforced functionally graded (FG) rubber core is investigated in flat-wise mode. FG samples are prepared using conventional casting technique. Presence of gradation is quantified ...

  3. X-joints in composite sandwich panels

    NARCIS (Netherlands)

    Vredeveldt, A.W.; Janssen, G.Th.M.

    1998-01-01

    The small structural weight of fast large ships such as fast mono hulls or catamaran type of ships is of extreme importance to their success. One possible light weight structural solution is the sandwich panel with fibre reinforced laminates and a balsa, honeycomb or foam core. A severe obstacle for

  4. Buckling driven debonding in sandwich columns

    DEFF Research Database (Denmark)

    Østergaard, Rasmus Christian

    2008-01-01

    results from two mechanisms: (a) interaction of local debond buckling and global buckling and (b) the development of a damaged zone at the debond crack tip. Based on the pronounced imperfection sensitivity, the author predicts that an experimental measurement of the strength of sandwich structures may...... exhibit a large scatter caused by geometrical variations between test specimens. (C) 2007 Elsevier Ltd. All rights reserved....

  5. Compressive properties of sandwiches with functionally graded ...

    Indian Academy of Sciences (India)

    fly ash by weight. Finally, the cured core sample is removed from the mold and the edges are trimmed. To prepare the sandwich skins, a bi-directional woven jute fabric procured from M/S Barde Agencies, Belgaum, Kar- nataka, India is used. This fabric is cut into layers of dimen- sions 55 mm × 55 mm in required orientation.

  6. Natural fabric sandwich laminate composites: development and ...

    Indian Academy of Sciences (India)

    A scanning electron microscope (SEM) and optical microscope are used for qualitative analysis of NFSL composites' interfacial properties. Two layers of jute and three layers of linen sandwich laminate have registered peak values in tensile and impact properties. The five layers of linen laminate composite have exhibited ...

  7. Structural detailing of openings in sandwich panels

    NARCIS (Netherlands)

    Tomà, T.; Courage, W.

    1996-01-01

    European Recommendations exist which provide calculation rules to determine the strength and stiffness of sandwich panels composed of two metal faces with a foam in between. In case of openings in such panels (e.g. for windows) an influence will appear with regard to the stiffness and loadbearing

  8. Organometallic half-sandwich iridium anticancer complexes

    NARCIS (Netherlands)

    Liu, Z.; Habtemariam, A.; Pizarro, A.M.; Fletcher, S.A.; Kisova, A.; Vrana, O.; Salassa, L.; Bruijnincx, P.C.A.|info:eu-repo/dai/nl/33799529X; Clarkson, G.J.; Brabec, V.; Sadler, Peter J.

    2011-01-01

    The low-spin 5d6 IrIII organometallic half-sandwich complexes [(η5-Cpx)Ir(XY)Cl]0/+, Cpx = Cp*, tetramethyl(phenyl)cyclopentadienyl (Cpxph), or tetramethyl(biphenyl)cyclopentadienyl (Cpxbiph), XY = 1,10-phenanthroline (4−6), 2,2′-bipyridine (7−9), ethylenediamine (10 and 11), or picolinate (12−14),

  9. [Multicenter study of commercial kits for the determination of human IgG subclasses, using the ELISA technique].

    Science.gov (United States)

    Pontet, F; Pressac, M; Musset, L; Tapon-Bretaudière, J; Jehl, C; Cailliez, M; Bienvenu, F

    1994-01-01

    We evaluated two commercially available sandwich type Elisa procedures for the measurement of IgG subclasses in human serum. Assay kits from The Binding Site and the Central Laboratory of the Netherlands Red Cross Blood Transfusion Service were tested in six laboratories. The performance of spectrophotometers, pipettes and dilutors were assessed at each center. Within-run precision was estimated according to the Valtec method (Société Française de Biologie Clinique). The overall coefficient of variation ranged from 4 to 50% depending on subclass and kit. We also evaluated the IgG2 and IgG4 specificity using four sera containing a monoclonal IgG2 or IgG4 (kappa or lambda type). Using total IgG and immunoelectrophoresis as a comparative technique, IgG2 kappa and IgG4 kappa were both underestimated, IgG2 lambda was overestimated while IgG4 lambda compared favorably. Polyclonal IgG subclasses were frequently overestimated in these sera suggesting cross-reactions with either monoclonal IgG or other polyclonal IgG. Antigen excess was investigated and not encountered with either kit. Our results demonstrate that these procedures are insufficiently accurate or precise for routine clinical use.

  10. Experimental Study of the Bending Properties and Deformation Analysis of Web-Reinforced Composite Sandwich Floor Slabs with Four Simply Supported Edges

    Science.gov (United States)

    Qi, Yujun; Fang, Hai; Liu, Weiqing

    2016-01-01

    Web-reinforced composite sandwich panels exhibit good mechanical properties in one-way bending, but few studies have investigated their flexural behavior and deformation calculation methods under conditions of four simply supported edges. This paper studies the bending performance of and deformation calculation methods for two-way web-reinforced composite sandwich panels with different web spacing and heights. Polyurethane foam, two-way orthogonal glass-fiber woven cloth and unsaturated resin were used as raw materials in this study. Vacuum infusion molding was used to prepare an ordinary composite sandwich panel and 5 web-reinforced composite sandwich panels with different spacing and web heights. The panels were subjected to two-way panel bending tests with simple support for all four edges. The mechanical properties of these sandwich panels during the elastic stage were determined by applying uniformly distributed loads. The non-linear mechanical characteristics and failure modes were obtained under centrally concentrated loading. Finally, simulations of the sandwich panels, which used the mechanical model established herein, were used to deduce the formulae for the deflection deformation for this type of sandwich panel. The experimental results show that webs can significantly improve the limit bearing capacity and flexural rigidity of sandwich panels, with smaller web spacing producing a stronger effect. When the web spacing is 75 mm, the limit bearing capacity is 4.63 times that of an ordinary sandwich panel. The deduced deflection calculation formulae provide values that agree well with the measurements (maximum error panel. PMID:26871435

  11. FINITE ELEMENT MODELING OF THIN CIRCULAR SANDWICH PLATES DEFLECTION

    Directory of Open Access Journals (Sweden)

    K. S. Kurachka

    2014-01-01

    Full Text Available A mathematical model of a thin circular sandwich plate being under the vertical load is proposed. The model employs the finite element method and takes advantage of an axisymmetric finite element that leads to the small dimension of the resulting stiffness matrix and sufficient accuracy for practical calculations. The analytical expressions for computing local stiffness matrices are found, which can significantly speed up the process of forming the global stiffness matrix and increase the accuracy of calculations. A software is under development and verification. The discrepancy between the results of the mathematical model and those of analytical formulas for homogeneous thin circularsandwich plates does not exceed 7%.

  12. Fate of Estrogens in Soils and Detection by ELISA

    Science.gov (United States)

    Caron, Emmanuelle; Sheedy, Claudia; Farenhorst, Annemieke; Zvomuya, Francis; Gaultier, Jeanette; Goddard, Tom

    2010-05-01

    Land application of manure can contribute to the release of estrogenic compounds in the environment. Estrogens may move from soils to water by processes such as runoff and leaching. The objectives of the present study were to determine the fate of estrogens in soils and to develop a detection method for these compounds. The sorption (soil sorption coefficient (Kd) and sorption coefficient per unit organic carbon (Koc)) of 17β-estradiol, estrone, estriol and equol were studied, using batch equilibrium experiments, in 121 surface soils from Alberta, Canada. The mineralization of [4-14C] 17β-estradiol was determined in soil microcosms in a subset of 36 samples. Quantitative relationships at the regional level were explored using partial least squares regression (PLS) (between Kd or Koc values and soil properties) and by ordinary least squares regression (between Kd or Koc values of different estrogens). Soil properties (r2 0.51-0.87 for Kd and 0.32-0.44 for Koc) provided better prediction models than using the data of different estrogens (r2 0.38-0.71 for Kd and 0.18-0.40 for Koc). PLS regression models for mineralization parameters of 17ß-estradiol had lower predictive power (lower r2)than models developed for sorption parameters. In addition, it has become of primary importance to develop sensitive detection methods that are able to detect low estrogen concentrations (ng L-1) in a wide variety of environmental matrices in order to validate the prediction of their fate and to study their presence in affected ecosystems. Conjugates were synthesized using a mixed anhydride reaction and two Enzyme-Linked Immunosorbent Assays (ELISAs) were developed using polyclonal antibodies. One ELISA was highly specific for 17β-estradiol (with an IC50 of 243 ng mL-1) and the second allowed for the broader detection of 17β-estradiol, estrone and estriol (with an IC50 of 18 ng mL-1 for 17β-estradiol). The cross-reactivity of both ELISAs was studied against 13 compounds (natural

  13. Herpes simplex virus type 2 antibody detection performance in Kisumu, Kenya, using the Herpeselect ELISA, Kalon ELISA, Western blot and inhibition testing.

    Science.gov (United States)

    Smith, J S; Bailey, R C; Westreich, D J; Maclean, I; Agot, K; Ndinya-Achola, J O; Hogrefe, W; Morrow, R A; Moses, S

    2009-04-01

    In certain parts of Africa, type-specific herpes simplex virus type 2 (HSV-2) ELISAs may have limited specificity. To date, no study has been conducted to validate HerpeSelect and Kalon type-specific HSV-2 ELISAs using both the Western blot and recombinant gG ELISA inhibition testing as reference standards. A total of 120 men who were HIV seronegative (aged 18-24 years) provided blood samples. HSV-2 IgG serum antibodies were detected using four different methods: HerpeSelect HSV-2 ELISA (n = 120), Kalon HSV-2 ELISA (n = 120), University of Washington Western blot (n = 101) and a recombinant inhibition test (n = 93). HSV-2 seroprevalence differed significantly by HSV-2 detection method, ranging from 24.8% with the Western blot to 69.8% with the HerpeSelect ELISA. Using the Western blot as the reference standard, the HerpesSelect had the highest sensitivity for HSV-2 antibody detection (100%) yet lowest specificity (40%). Similar results were obtained using the inhibition test as the reference standard. The sensitivity and specificity of the Kalon test versus the Western blot were 92% and 79%, respectively, and 80% and 82% versus the inhibition test. Using the inhibition test as the reference standard, the sensitivity of the Western blot appeared low (49%). In men in western Kenya who were HIV seronegative, the HerpeSelect and Kalon type-specific ELISAs had high sensitivities yet limited specificities using the Western blot as reference standard. Overall, the Kalon ELISA performed better than the HerpeSelect ELISA in these young men from Kisumu. Further understanding is needed for the interpretation of HSV-2 inhibition or ELISA test positive/ Western blot seronegative results. Before HSV-2 seropositivity may be reliably reported in selected areas of Africa, performance studies of HSV-2 serological assays in individual geographical areas are recommended.

  14. Degradation of shear stiffness of Nomex honeycomb sandwich panel in laser irradiation

    Science.gov (United States)

    Wang, Jiawei; Jiang, Houman; Wu, Lixiong; Zhu, Yongxiang; Wei, Chenghua; Ma, Zhiliang; Wang, Lijun

    2017-05-01

    Based on the overhanging beam three-point bending method, the experimental system was set up to measure the variety of shear stiffness of Nomex honeycomb sandwich panel in laser irradiation. The shear stiffness of the specimens under different laser power density was measured. The result shows that the thermal effect during the laser irradiation leads to the degradation of mechanical properties of Nomex honeycomb sandwich panel. High temperature rise rate in the specimen is another main reason for the shear stiffness degeneration. This research provides a reference for the degradation of mechanical properties of composite materials in laser irradiation and proposes a new method for the study of laser interaction with matter.

  15. ELISA for the serology of FIP virus.

    NARCIS (Netherlands)

    A.D.M.E. Osterhaus (Albert); A. Kroon; R.M.S. Wirahadiredja

    1979-01-01

    textabstractAn enzyme linked immunosorbent assay (ELISA) for feline infectious peritonitis (FIP) virus serology is described. The assay is analogous to a previously developed indirect heterologous immunofluorescence test (IFT) in which transmissible gastroenteritis (TGE) viral antigen was used.

  16. Clinical evaluation of the Serum CrossLaps One Step ELISA, a new assay measuring the serum concentration of bone-derived degradation products of type I collagen C-telopeptides

    DEFF Research Database (Denmark)

    Christgau, S; Rosenquist, C; Alexandersen, P

    1998-01-01

    The Serum CrossLaps One Step ELISA is a sandwich assay using two monoclonal antibodies specific for a beta-aspartate form of the epitope EKAHDGGR derived from the carboxy-terminal telopeptide region of type I collagen alpha1-chain. Our objective was to assess the clinical value of the Serum Cross...

  17. ANALISA TEKNIS DAN EKONOMIS PENGGUNAAN COREMAT UNTUK KONSTRUKSI FRP (FIBERGLASS REINFORCED PLASTIC SANDWICH PADA BADAN KAPAL

    Directory of Open Access Journals (Sweden)

    Parlindungan Manik

    2012-04-01

    Full Text Available Planning of ship construction is make its having good effectivity value and efficiency. Composite as material alternative to changes of steel feedstock and wood has many applied named FRP (fiberglass reinforced plastics single skin. The weakness of this FRP was heavy construction and requires many production time. Therefore, will be checked comparison between single skin with sandwich constructions for shell. In this research, the way for making composite is hand lay up method with three various thickness of skin there are : t, t/2, and t/4. To know strength comparison from the various skin of sandwich with single skin, must be test, consist of tensile test.. The result is analyzed then compared by BKI (Biro Klasifikasi Indonesia rules for the fiberglass ship. Based on the result, indicates that optimization skin thickness of sandwich construction applies Coremat which tensile strength it is equivalent with Single Skin at 2/3t and usage of Sandwich construction causes 23,12 % lighter. In economic analyze, advantage from low weight is compensation of addition 23,12 % DWT. Material cost for Sandwich about 11,35% bigger than Single Skin construction.

  18. ANALISA TEKNIS DAN EKONOMIS PENGGUNAAN COREMAT UNTUK KONSTRUKSI FRP (FIBERGLASS REINFORCED PLASTIC SANDWICH PADA BADAN KAPAL

    Directory of Open Access Journals (Sweden)

    Parlindungan Manik

    2012-02-01

    Full Text Available Planning of ship construction is make its having good effectivity value and efficiency. Composite as materialalternative to changes of steel feedstock and wood has many applied named FRP (fiberglass reinforcedplastics single skin. The weakness of this FRP was heavy construction and requires many production time.Therefore, will be checked comparison between single skin with sandwich constructions for shell.In this research, the way for making composite is hand lay up method with three various thickness of skinthere are : t, t/2, and t/4. To know strength comparison from the various skin of sandwich with single skin,must be test, consist of tensile test.. The result is analyzed then compared by BKI (Biro Klasifikasi Indonesiarules for the fiberglass ship.Based on the result, indicates that optimization skin thickness of sandwich construction applies Corematwhich tensile strength it is equivalent with Single Skin at 2/3t and usage of Sandwich construction causes23,12 % lighter. In economic analyze, advantage from low weight is compensation of addition 23,12 % DWT.Material cost for Sandwich about 11,35% bigger than Single Skin construction.

  19. Experimental investigation on the dynamic response of clamped corrugated sandwich plates subjected to underwater impulsive loadings

    Science.gov (United States)

    Huang, Wei; Zhang, Wei; Li, Dacheng; Hypervelocity Impact Research Center Team

    2015-06-01

    Corrugated sandwich plates are widely used in marine industry because such plates have high strength-to-weight ratios and blast resistance. The laboratory-scaled fluid-structure interaction experiments are performed to demonstrate the shock resistance of solid monolithic plates and corrugated sandwich plates by quantifying the permanent transverse deflection at mid-span of the plates as a function of impulsive loadings per areal mass. Sandwich structures with 6mm-thick and 10mm-thick 3003 aluminum corrugated core and 5A06 face sheets are compared with the 5A06 solid monolithic plates in this paper. The dynamic deformation of plates are captured with the the 3D digital speckle correlation method (DIC). The results affirm that sandwich structures show a 30% reduction in the maximum plate deflection compare with a monolithic plate of identical mass per unit area, and the peak value of deflection effectively reduced by increasing the thickness core. The failure modes of sandwich plates consists of core crushing, imprinting, stretch tearing of face sheets, bending and permanent deformation of entire structure with the increasing impulsive loads, and the failure mechanisms are analyzed with the postmortem panels and dynamic deflection history captured by cameras. National Natural Science Foundation of China (NO.: 11372088).

  20. ELISA for complexes between urokinase-type plasminogen activator and its receptor in lung cancer tissue extracts

    DEFF Research Database (Denmark)

    de Witte, H; Pappot, H; Brünner, N

    1997-01-01

    A sandwich-type ELISA has been developed for the assessment of complexes between urokinase-type plasminogen activator (uPA) and its receptor (uPAR) in extracts of squamous cell lung carcinomas. The assay is based on a combination of rabbit polyclonal anti-uPA antibodies and a biotinylated mouse a......PA:uPAR complexes in lung tumor tissue as well as other types of cancer.......A sandwich-type ELISA has been developed for the assessment of complexes between urokinase-type plasminogen activator (uPA) and its receptor (uPAR) in extracts of squamous cell lung carcinomas. The assay is based on a combination of rabbit polyclonal anti-uPA antibodies and a biotinylated mouse...... anti-uPAR monoclonal antibody (MAb). The detection limit of the assay is approximately 0.5 fmol/ml. A linear dose-response is obtained with up to 40 fmol/ml of uPA:uPAR complexes, while uPA and uPAR separately do not cause any response in the ELISA. A buffer which has been used previously for optimal...

  1. Buckling optimisation of sandwich cylindrical panels

    Science.gov (United States)

    Abouhamzeh, M.; Sadighi, M.

    2016-06-01

    In this paper, the buckling load optimisation is performed on sandwich cylindrical panels. A finite element program is developed in MATLAB to solve the governing differential equations of the global buckling of the structure. In order to find the optimal solution, the genetic algorithm Toolbox in MATLAB is implemented. Verifications are made for both the buckling finite element code and also the results from the genetic algorithm by comparisons to the results available in literature. Sandwich cylindrical panels are optimised for the buckling strength with isotropic or orthotropic cores with different boundary conditions. Results are presented in terms of stacking sequence of fibers in the face sheets and core to face sheet thickness ratio.

  2. Utilization of Bamboo as Lightweight Sandwich Panels

    Directory of Open Access Journals (Sweden)

    Suthon SRIVARO

    2016-05-01

    Full Text Available Lightweight sandwich panels consisting of bamboo faces and oil palm trunk core were manufactured using melamine urea formaldehyde with the resin content of 250 g/m2 (solid basis. The parameters examined were node and density of bamboo faces. Physical (board density, thickness swelling and water absorption and mechanical (modulus of elasticity and modulus of rupture properties of the sandwich board obtained were investigated and compared with other bamboo products and commercial wood based products. Result showed that this panel had better dimensional stability than those of other bamboo products but lower bending strength. Node of bamboo had no significant effect on any board properties examined. Most of board properties were influenced by bamboo face density. Comparing the properties to commercial wood based products, this panel could be used as wall/floor applications.

  3. Impact response of balsa core sandwiches

    OpenAIRE

    Nurdane Mortas; Paulo N.B. Reis; José A.M. Ferreira

    2014-01-01

    The benefits of resins nano-enhanced on the impact response of sandwich composites made by fiber glass/epoxy skins and balsa wood core were studied. Afterwards, the influence of the core's discontinuity was analyzed in terms of impact strength. For better dispersion and interface adhesion matrix/clay nanoclays were previously subjected to a silane treatment appropriate to the epoxy resin. Resins enhanced by nanoclays promote higher maximum impact loads, lower displacements and the...

  4. RANDOM VIBRATION ANALYSIS OF SANDWICH COMPOSITE BEAMS

    OpenAIRE

    K. Ravindranath Tagore, Rachumalla Pallavi

    2016-01-01

    In this thesis, a sandwich composite for Semi-monocoque construction in aircraft fuselage is analyzed for its strength under different loading conditions using different materials for Stringers balsa wood, syntactic foams, and honeycombs and Carbon Fiber reinforced thermoplastics is used as skin material. 3D modeling is done in Pro/Engineer. Static, Modal and Random Vibration analysis is done on the beam using finite element analysis software Ansys.

  5. Investigation on vibration excitation of debonded sandwich structures using time-average digital holography.

    Science.gov (United States)

    Thomas, Binu P; Annamala Pillai, S; Narayanamurthy, C S

    2017-05-01

    Sandwich structures, in the modern aerospace industry, are more sought after due to their high strength to stiffness ratio resulting in significant weight gains. Optical techniques like time-average holography and shearography are preferred in industries for inspection of huge sandwich and composite panels because of whole-field (full coverage) inspection in a lesser time leading to large savings in cost. These techniques conventionally use sinusoidal frequency sweep to capture the local resonance of defective regions. This paper highlights the difficulties with the conventional approach of time-average digital holography (TADH) and proposes a novel defect identification strategy through square wave excitation. The proposed method enhances the speed and accuracy of inspection; thereby it saves cost and increases confidence level. Extensive experiments have been carried out using honeycomb sandwich panels to demonstrate the methodology.

  6. Dynamic Response of Soft Core Sandwich Beams with Metal-Graphene Nanocomposite Skins

    Directory of Open Access Journals (Sweden)

    M. A. R. Loja

    2017-01-01

    Full Text Available Sandwich structures are able to provide enhanced strength, stiffness, and lightweight characteristics, thus contributing to an improved overall structural response. To this sandwich configuration one may associate through-thickness graded core material properties and homogeneous or graded properties nanocomposite skins. These tailor-made possibilities may provide alternative design solutions to specific problem requisites. This work aims to address these possibilities, considering to this purpose a package of three beam layerwise models based on different shear deformation theories, implemented through Kriging-based finite elements. The viscoelastic behaviour of the sandwich core is modelled using the complex method and the dynamic problem is solved in the frequency domain. A set of case studies illustrates the performance of the models.

  7. Deformation and fracture of impulsively loaded sandwich panels

    Science.gov (United States)

    Wadley, H. N. G.; Børvik, T.; Olovsson, L.; Wetzel, J. J.; Dharmasena, K. P.; Hopperstad, O. S.; Deshpande, V. S.; Hutchinson, J. W.

    2013-02-01

    Light metal sandwich panel structures with cellular cores have attracted interest for multifunctional applications which exploit their high bend strength and impact energy absorption. This concept has been explored here using a model 6061-T6 aluminum alloy system fabricated by friction stir weld joining extruded sandwich panels with a triangular corrugated core. Micro-hardness and miniature tensile coupon testing revealed that friction stir welding reduced the strength and ductility in the welds and a narrow heat affected zone on either side of the weld by approximately 30%. Square, edge clamped sandwich panels and solid plates of equal mass per unit area were subjected to localized impulsive loading by the impact of explosively accelerated, water saturated, sand shells. The hydrodynamic load and impulse applied by the sand were gradually increased by reducing the stand-off distance between the test charge and panel surfaces. The sandwich panels suffered global bending and stretching, and localized core crushing. As the pressure applied by the sand increased, face sheet fracture by a combination of tensile stretching and shear-off occurred first at the two clamped edges of the panels that were parallel with the corrugation and weld direction. The plane of these fractures always lay within the heat affected zone of the longitudinal welds. For the most intensively loaded panels additional cracks occurred at the other clamped boundaries and in the center of the panel. To investigate the dynamic deformation and fracture processes, a particle-based method has been used to simulate the impulsive loading of the panels. This has been combined with a finite element analysis utilizing a modified Johnson-Cook constitutive relation and a Cockcroft-Latham fracture criterion that accounted for local variation in material properties. The fully coupled simulation approach enabled the relationships between the soil-explosive test charge design, panel geometry, spatially varying

  8. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    OpenAIRE

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-St...

  9. Face/core debond fatigue crack growth characterization using the sandwich mixed mode bending specimen

    DEFF Research Database (Denmark)

    Manca, Marcello; Quispitupa, Amilcar; Berggreen, Christian

    2012-01-01

    Face/core fatigue crack growth in foam-cored sandwich composites is examined using the mixed mode bending (MMB) test method. The mixed mode loading at the debond crack tip is controlled by changing the load application point in the MMB test fixture. Sandwich specimens were manufactured using H45...... and H100 PVC foam cores and E-glass/polyester face sheets. All specimens were pre-cracked in order to define a sharp crack front. The static debond fracture toughness for each material configuration was measured at different mode-mixity phase angles. Fatigue tests were performed at 80% of the static...

  10. A J Integral Approach for Measuring Cohesive Laws Using a Modified DCB Sandwich Specimen

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Sørensen, Bent F.

    2007-01-01

    mode mixities. The sandwich specimen consists of glass fiber faces and Divinycell H200 foam core. Arbitrary stiffening of the sandwich specimen with steel bars adhered to the faces reduces rotations and ensures that the method is useable for a wide range of materials. The J integral is employed...... and the opening of the pre-crack tip is recorded by a commercial digital photogrammetry measurement system. Cohesive laws are extracted by differentiating J with respect to the normal and tangential opening of the pre-crack tip. Some results are presented and discussed....

  11. A novel indirect ELISA for diagnosis of dengue fever

    Directory of Open Access Journals (Sweden)

    Rohan Narayan

    2016-01-01

    Full Text Available Background & objectives: Dengue fever (DF is associated with significant morbidity and mortality in the tropical and sub-tropical regions of the world. Since there are no effective antiviral drugs for treatment, clinicians often rely on the accurate diagnosis of dengue fever to begin supportive therapy at early stages of the illness. The objective of this study was to develop an in-house dengue virus serotype 2 (DENV-2 non-structural protein- 5 (NS5 based indirect ELISA. Methods: DENV-2 was raised in Vero cells and the viral proteins were separated and subsequently the NS5 protein was eluted. Serum samples from primary and secondary dengue fever patients; and acute and convalescent samples from Japanese encephalitis (JE and West Nile virus (WNV cases were used to validate the ELISA. Results: The assay was found to be 100 per cent specific in detecting DENV-2 specific antibodies from patient′s serum. However, in terms of sensitivity, the assay could detect IgM antibodies only from 90 per cent of the primary dengue samples. The IgM/IgG ratio of the primary and secondary samples was 7.24 and 0.64, respectively. Interpretation & conclusions: The results indicate that the DENV-2 NS5 ELISA is dengue group specific and can be used to differentiate dengue infection from other circulating Flavivirus infections. This NS5 ELISA can also be used to distinguish between primary and secondary dengue fever on the basis of IgM/IgG ratios. Further studies with larger sample sizes and different DENV serotypes are required to validate the ELISA.

  12. Low-Velocity Impact Response of Sandwich Beams with Functionally Graded Core

    Science.gov (United States)

    Apetre, N. A.; Sankar, B. V.; Ambur, D. R.

    2006-01-01

    The problem of low-speed impact of a one-dimensional sandwich panel by a rigid cylindrical projectile is considered. The core of the sandwich panel is functionally graded such that the density, and hence its stiffness, vary through the thickness. The problem is a combination of static contact problem and dynamic response of the sandwich panel obtained via a simple nonlinear spring-mass model (quasi-static approximation). The variation of core Young's modulus is represented by a polynomial in the thickness coordinate, but the Poisson's ratio is kept constant. The two-dimensional elasticity equations for the plane sandwich structure are solved using a combination of Fourier series and Galerkin method. The contact problem is solved using the assumed contact stress distribution method. For the impact problem we used a simple dynamic model based on quasi-static behavior of the panel - the sandwich beam was modeled as a combination of two springs, a linear spring to account for the global deflection and a nonlinear spring to represent the local indentation effects. Results indicate that the contact stiffness of thc beam with graded core Increases causing the contact stresses and other stress components in the vicinity of contact to increase. However, the values of maximum strains corresponding to the maximum impact load arc reduced considerably due to grading of thc core properties. For a better comparison, the thickness of the functionally graded cores was chosen such that the flexural stiffness was equal to that of a beam with homogeneous core. The results indicate that functionally graded cores can be used effectively to mitigate or completely prevent impact damage in sandwich composites.

  13. Development of an indirect ELISA method for the parallel measurement of IgG and IgM antibodies against Crimean-Congo haemorrhagic fever (CCHF) virus using recombinant nucleoprotein as antigen.

    Science.gov (United States)

    Dowall, S D; Richards, K S; Graham, V A; Chamberlain, J; Hewson, R

    2012-02-01

    Recombinant nucleoprotein from Crimean-Congo Haemorrhagic Fever (CCHF) virus was successfully derived from a baculovirus expression system and purified for use in a novel enzyme-linked immunosorbent assay (ELISA) diagnostic test. Comparable tests were used for detection of IgG and IgM antibodies, thus allowing efficient detection of both antibodies in parallel. The major benefits of the assay also included removing any requirement for polyclonal sera, thus eliminating variation in preparations and allowing standardisation between laboratories. The assay was successfully tested using a panel of positive sera supplied from samples identified as being positive in Turkey, Tajikistan and Kosovo and shown to be sensitive and specific. It is envisaged that this simple diagnostic ELISA for CCHF virus infection which removes the reliance on polyclonal antibody preparations, will be accessible to a wider range of laboratories enabling them to carry out routine diagnosis. This will improve the efficiency of diagnosis and subsequent management of infected patients. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  14. Transferability of antibody pairs from ELISA to fiber optic surface plasmon resonance for infliximab detection

    Science.gov (United States)

    Van Stappen, Thomas; Lu, Jiadi; Bloemen, Maarten; Geukens, Nick; Spasic, Dragana; Delport, Filip; Verbiest, Thierry; Lammertyn, Jeroen; Gils, Ann

    2015-03-01

    Tumor necrosis factor (TNF)-alpha is a pleiotropic cytokine up-regulated in inflammatory bowel disease, rheumatoid arthritis and psoriasis. The introduction of anti-TNF drugs such as infliximab has revolutionized the treatment of these diseases. Recently, therapeutic drug monitoring (TDM) of infliximab has been introduced in clinical decision making to increase cost-efficiency. Nowadays, TDM is performed using radio-immunoassays, homogeneous mobility shift assays or ELISA. Unfortunately, these assays do not allow for in situ treatment optimization, because of the required sample transportation to centralized laboratories and the subsequent assay execution time. In this perspective, we evaluated the potential of fiber optic-surface plasmon resonance (FO-SPR). To achieve this goal, a panel of 55 monoclonal anti-infliximab antibodies (MA-IFX) was developed and characterized in-house, leading to the identification of nine different clusters. Based on this high diversity, 22 antibody pairs were selected and tested for their reactivity towards IFX, using one MA-IFX as capture and one MA-IFX for detection, in a sandwich type ELISA and FO-SPR. This study showed that the reactivity towards IFX of each antibody pair in ELISA is highly similar to its reactivity on FO-SPR, indicating that antibody pairs are easily transferable between both platforms. Given the fact that FO-SPR shows the potential for miniaturization and fast assay time, it can be considered a highly promising platform for on-site infliximab monitoring.

  15. Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.

    Directory of Open Access Journals (Sweden)

    Nadja Sparding

    Full Text Available After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.

  16. Evaluation of IgY capture ELISA for sensitive detection of alpha hemolysin of Staphylococcus aureus without staphylococcal protein A interference.

    Science.gov (United States)

    Reddy, Prakash Kudumala; Shekar, Aravind; Kingston, Joseph Jeyabalaji; Sripathy, Murali Harishchandra; Batra, Harshvardhan

    2013-05-31

    Staphylococcal protein A (Spa) secreted by all Staphylococcus aureus strains is the major hindrance in development of specific immunoassays for detecting S. aureus antigens, because of its characteristic feature of binding to Fc region of most mammalian immunoglobulins and also to Fab region of certain classes of mammalian immunoglobulins. Immunoglobulin Y (IgY) is the avian equivalent of mammalian IgG which does not have any affinity to Spa. In the present study we report that using chicken egg yolk IgY over mammalian IgG as capture antibody prevents both soluble and surface bound protein A from causing false positives quantified by chicken anti-protein A antibodies. This was demonstrated by development of sandwich ELISA for detection of alpha hemolysin toxin from culture supernatants of S. aureus strains with anti alpha hemolysin IgY as capture and rabbit anti alpha hemolysin IgG as revealing antibody. This indirect sandwich ELISA was evaluated onto a large number of S. aureus isolates recovered from clinical sources for alpha hemolysin secretion. Results of sandwich ELISA were compared with PCR and Western blot analysis. The immunoassay is highly specific and has high sensitivity of detecting less than 1 ng/ml. This procedure is highly effective in eliminating Spa interference and can be extended to detection of other important superantigen toxins of S. aureus. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Soon-Ching; Low, Kaw-Sai [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Jalan Genting Kelang, Setapak, 53300 Kuala Lumpur, Wilayah Persekutuan (Malaysia)

    2010-12-15

    Investigation on the thermal conductivity of newspaper sandwiched aerated lightweight concrete (ALC) panels is the main purpose of this study. Various densities of ALC panels ranging from 1700, 1400 and 1100 kg/m{sup 3} with three different aerial intensities of newspaper sandwiched were produced. Investigation was limited to the effect of aerial intensity of newspaper sandwiched and the effect of density of ALC on thermal conductivity. It is found that the thermal conductivity of newspaper sandwiched ALC panels reduced remarkably compared to control ALC panels. The reduction was recorded at 18.0%, 21.8% and 20.7% correspond to densities of 1700, 1400 and 1100 kg/m{sup 3} with just a mere 0.05 g/cm{sup 2} aerial intensity of newspaper sandwiched. Newspaper sandwiched has a significant impact on the performance of thermal conductivity of ALC panels based on regression analysis. (author)

  18. Combined shear/compression structural testing of asymmetric sandwich structures

    OpenAIRE

    Castanié, Bruno; Barrau, Jean-Jacques; Jaouen, Jean-Pierre; Rivallant, Samuel

    2004-01-01

    Asymmetric sandwich technology can be applied in the design of lightweight, non-pressurized aeronautical structures such as those of helicopters. A test rig of asymmetric sandwich structures subjected to compression/shear loads was designed, validated, and set up. It conforms to the standard certification procedure for composite aeronautical structures set out in the “test pyramid”, a multiscale approach. The static tests until failure showed asymmetric sandwich structures to be extremely res...

  19. Determination of Peroxide Value of Edible Oils Used in Restaurants and Sandwich Shops in Yasuj in 2006

    Directory of Open Access Journals (Sweden)

    A Pourmahmoudi

    2008-04-01

    Full Text Available ABSTRACT: Introduction & Objective: Nowadays the extensive changes in lifestyle resulted in an increase in consumption of fast food. This type of food, because of using deep–fat frying, may contain some toxic or unfavorable substances which have adverse effects on consumers’ health. The aim of this study was to determine the peroxide value of edible oils which are used in restaurants and sandwich shops in Yasouj city. Materials & Methods: This descriptive study was carried out on all sandwich shops (n=36 and restaurants (n=12 in Yasuj city in 2006. All samples and questionnaire data in restaurants and sandwich shops were collected at 11:30am and 12:30pm respectively based on a national standard protocol, number 493, by a food expert. The peroxide value was determined based on national standard procedure, number 4179, in a food laboratory and the acceptable limit was defined as 7 meq/kg. Results: Findings of this study showed that in terms of health rules and regulations, at least 50% of oils used in restaurants and 70% in sandwich shops were unfavorable. Peroxide value of 58.3% of oils in restaurants and 97.3% in sandwich shops was greater than the acceptable limit. Conclusion: These findings have shown that the health rules and regulations for the oils are not exercised in Yasouj restaurants and sandwich shops and this can have adverse effects on consumers’ health.

  20. Bayesian estimation of sensitivity and specificity of Coxiella burnetii antibody ELISA tests in bovine blood and milk

    DEFF Research Database (Denmark)

    Paul, Suman; Toft, Nils; Agerholm, Jørgen S.

    2013-01-01

    Serological tests for Coxiella burnetii (the causative agent of Q fever) antibodies are usually based on enzyme linked immunosorbent assay (ELISA) although this method is not thoroughly evaluated. The objective of this study was to determine the sensitivity and specificity of an ELISA for detection...... of the ELISA methods on milk and blood were equal at 0.99. No conditional dependence was observed between the specificity estimates of the two test methods. However, the sensitivity estimates of both tests were significantly reduced when conditional covariances ≥40 were used. Collection of milk samples from...... to positive (S/P) cut-off of 40 for both blood and milk ELISAs. At this cut-off, sensitivity of milk ELISA was 0.86 (95% posterior credibility interval [PCI] [0.76; 0.96]). This was slightly but insignificantly higher than sensitivity of blood ELISA (0.84; 95% PCI [0.75; 0.93]). The specificity estimates...

  1. The sandwich generation copes with elder care.

    Science.gov (United States)

    Seaward, M R

    1999-01-01

    The "sandwich generation" refers to the demographic age group of individuals who are caring for young children and elder parents at the same time. The increasing number of employees who must care for children and parents alike is a trend that is projected to continue. This is a burdensome responsibility that can cause stress and result in loss of productivity, accompanied by higher cost, to employers. The author discusses elder-care services that employers can offer to enhance productivity and gives case examples of companies that are making elder-care benefits available to employees.

  2. Impact response of balsa core sandwiches

    Directory of Open Access Journals (Sweden)

    Nurdane Mortas

    2014-10-01

    Full Text Available The benefits of resins nano-enhanced on the impact response of sandwich composites made by fiber glass/epoxy skins and balsa wood core were studied. Afterwards, the influence of the core's discontinuity was analyzed in terms of impact strength. For better dispersion and interface adhesion matrix/clay nanoclays were previously subjected to a silane treatment appropriate to the epoxy resin. Resins enhanced by nanoclays promote higher maximum impact loads, lower displacements and the best performance in terms of elastic recuperation. The core's discontinuity decreases the impact strength, but the resin enhanced by nanoclays promotes significant benefits.

  3. Rapid analysis of methamphetamine in hair by micropulverized extraction and microchip-based competitive ELISA.

    Science.gov (United States)

    Miyaguchi, Hajime; Takahashi, Hiroko; Ohashi, Toshinori; Mawatari, Kazuma; Iwata, Yuko T; Inoue, Hiroyuki; Kitamori, Takehiko

    2009-01-30

    An automated full-range quantitation method for identifying d-methamphetamine in human hair using a microchip-based ELISA system (microELISA) in combination with a micropulverized extraction method for sample preparation has been developed. An antibody and a peroxidase-linked methamphetamine, both are commercially available, were used for the competitive ELISA assay. Method validation was carried out using doped hair samples, and segmental analyses of real-case specimens were carried out by both microELISA and LC/MS/MS to verify the reliability and applicability of this new method. Due to the small size of the system and the lack of an evaporation process, sample preparation and quantitation can be accomplished easily and quickly (less than 30 min) in small-scale contamination-free environments.

  4. Development and evaluation of a sandwich ELISA for quantification of the 20S proteasome in human plasma

    DEFF Research Database (Denmark)

    Dutaud, Dominique; Aubry, Laurent; Henry, Laurent

    2002-01-01

    /ml with a slope of 1.004 and a coefficient of determination r2 of 0.99. In a preliminary experiment performed on a limited number of patients, the present assay was used to quantify the 20S proteasome in plasma from healthy subjects (n=11) and from a limited number of patients with various diseases (two patients...

  5. Evaluation of a polyclonal antibody based sandwich ELISA for the detection of faecal antigens in Schistosoma spindale infection in bovines

    OpenAIRE

    Sreenivasa Murthy, G. S.; D’Souza, Placid E.; Shrikrishna Isloor, K.

    2012-01-01

    Schistosomosis is a common parasitic infection in animals prevalent in cattle in Asia and Africa, where it is estimated that at least 165 million animals are infected. Out of the 10 species reported to naturally infect cattle only Schistosoma nasale and Schistosoma spindale have received particular attention, because of their recognized veterinary significance. Although animal schistosomes may, under rare conditions favouring intensive transmission, act as important pathogens in endemic areas...

  6. Evaluation of a polyclonal antibody based sandwich ELISA for the detection of faecal antigens in Schistosoma spindale infection in bovines

    National Research Council Canada - National Science Library

    Sreenivasa Murthy, G S; D’Souza, Placid E; Shrikrishna Isloor, K

    .... Out of the 10 species reported to naturally infect cattle only Schistosoma nasale and Schistosoma spindale have received particular attention, because of their recognized veterinary significance...

  7. Dynamics of glucagon secretion in mice and rats revealed using a validated sandwich ELISA for small sample volumes

    DEFF Research Database (Denmark)

    Albrechtsen, Nicolai Jacob Wewer; Kuhre, Rune Ehrenreich; Windeløv, Johanne Agerlin

    2016-01-01

    according to current analytical guidelines, including tests of sensitivity, specificity, and accuracy, and compare it, using the Bland-Altman algorithm and size-exclusion chromatography, with three other widely cited assays. After demonstrating adequate performance of the assay, we measured glucagon...

  8. Occurrence of Foodborne Pathogens in Chickens Sandwiches Distributed in Different Supermarkets of Tehran Province, Iran

    Directory of Open Access Journals (Sweden)

    Zohreh Mashak

    2014-07-01

    Full Text Available Background: Increasing urbanization, immigration and tourism has changed the human lifestyle. This modern lifestyle has demanded safety, quality, and fast availability of ready to eat (RTE foods like chicken sandwiches. Objectives: For presentation of proper solutions regarding food safety, identification of pathogens in different foods is necessary. Therefore, the present study was carried out to assess the microbiological quality of chicken sandwiches distributed in Tehran province, Iran. Materials and Methods: A total of 200 chicken sandwich samples (chicken sausage, chicken fillet, minced chicken fillet were purchased from different supermarkets in Tehran city randomly during 2013 and transported to the laboratory of food hygiene of Islamic Azad University, Karaj branch under temperature-controlled conditions for bacteriological examination by American Public Health Association (APHA method. Results: The average count ± standard error (and percent of unacceptable samples of S. aureus, B. cereus and Coliform were 1.6 ± 0.56 (28%, 2.0 ± 0.62 (10%, 4.2 ± 1.12 (50% CFU/g, respectively. Moreover, E. coli and Salmonella spp. were identified in 21% of chicken sandwich samples. Conclusions: The large number of foodborne pathogens detected in this study, represented a potential health hazard to consumers. Thus, it is necessary to employ Good Hygiene Practices (GHP and Hazard Analysis and Critical Control Points (HACCP in order to minimize the risk caused by secondary contamination.

  9. Nurse managers and the sandwich support model.

    Science.gov (United States)

    Chisengantambu, Christine; Robinson, Guy M; Evans, Nina

    2017-09-15

    To explore the interplay between the work of nurse managers and the support they receive and provide. Support is the cornerstone of management practices and is pivotal in employees feeling committed to an organisation. Support for nurse managers is integral to effective health sector management; its characteristics merit more attention. The experiences of 15 nurse managers in rural health institutions in South Australia were explored using structured interviews, observation and document review. Effective decision making requires adequate support, which influences the perceptions and performance of nurse managers, creating an environment in which they feel appreciated and valued. An ideal support system is proposed, the "sandwich support model," to promote effective functioning and desirable patient outcomes via support "from above" and "from below." The need to support nurse managers effectively is crucial to how they function. The sandwich support model can improve management practices, more effectively assisting nurse managers. Organisations should revisit and strengthen support processes for nurse managers to maximize efficiencies. This paper contributes to understanding the importance of supporting nurse managers, identifying the processes used and the type of support offered. It highlights challenges and issues affecting support practices within the health sector. © 2017 John Wiley & Sons Ltd.

  10. Dynamic Failure of Composite and Sandwich Structures

    CERN Document Server

    Abrate, Serge; Rajapakse, Yapa D S

    2013-01-01

    This book presents a broad view of the current state of the art regarding the dynamic response of composite and sandwich structures subjected to impacts and explosions. Each chapter combines a thorough assessment of the literature with original contributions made by the authors.  The first section deals with fluid-structure interactions in marine structures.  The first chapter focuses on hull slamming and particularly cases in which the deformation of the structure affects the motion of the fluid during the water entry of flexible hulls. Chapter 2 presents an extensive series of tests underwater and in the air to determine the effects of explosions on composite and sandwich structures.  Full-scale structures were subjected to significant explosive charges, and such results are extremely rare in the open literature.  Chapter 3 describes a simple geometrical theory of diffraction for describing the interaction of an underwater blast wave with submerged structures. The second section addresses the problem of...

  11. Parts Per Trillion Detection of 7-Aminonitrazepam by Nano-Enhanced ELISA

    Directory of Open Access Journals (Sweden)

    Feng Xue

    2013-09-01

    Full Text Available It is challenging to detect 7-aminonitrazepam (7-ANZP residue in animal tissues simply and sensitively by the enzyme-linked sorbent immunoassay (ELISA method. This paper demonstrates that utilizing a bioconjugate of gold nanoparticles and enzyme-labeled antibody as a signal probe increases the sensitivity of a traditional ELISA for 7-ANZP by nearly 20 times. The sensitivity of this ELISA for 7-ANZP was 5.6 pg/mL in buffer, and the limit of detection (LOD of 0.18 µg/kg for 7-ANZP in urine could be achieved after the urine samples were simply hydrolyzed and diluted by buffer. This simple and sensitive method has potential application for improving the sensitivity of ELISA methods against various small molecules.

  12. Efficacy demonstration of tetanus vaccines by double antigen ELISA.

    Science.gov (United States)

    Rosskopf, U; Noeske, K; Werner, E

    2005-09-01

    This paper describes a double antigen ELISA (DAE) for rapid, specific and reliable assessment of the antitetanus immune status of horses and sheep. Compared with the indirect ELISA, the double antigen ELISA has the advantage of species-independent testing of sera. Thanks to its test design, it is more specific since the detected antibodies are forced to bind tetanus toxoid twice. In addition, it is very sensitive to tetanus antibodies, enabling the detection of low antibody titres, in range which is relevant for the assessment of the protective status (tetanus toxin neutralising antibodies). The detection limit of the DAE for tetanus antibodies is in the order of 10(-4) EU/ml. A comparison of in vitro results of individual sera with in vivo titres showed that horse sera with titres of 0.04 and 0.05 EU/ml in the DAE showed titres of > 0.05 IU and 0.034 IU/ml respectively during in vivo testing thus indicating good agreement. For tested sheep sera which were rated > 0.05 IU/ml in vivo, the corresponding titre in the DAE was 0.24 EU/ml. Clear tetanus antitoxin establishment of protective ELISA limits requires further comparative examination of sera with low titres (tetanus vaccines ad us. vet. As a consequence, the toxin neutralisation test (still being the standard method of choice for quantifying tetanus toxin neutralising antitoxin titres) could be replaced, since it requires too great a number of animals per test and involves considerable suffering for the animals. The test described here reduces the use of mice and guinea pigs within vaccine efficacy testing. In addition, it involves less exposure of the laboratory personnel to toxin.

  13. Elisa Studio showroom = Elisa Studio showroom / Jan Joonas Graps ; kommenteerinud Tiina Kuusisto

    Index Scriptorium Estoniae

    Graps, Jan Joonas, 1972-

    2015-01-01

    Elisa Studio showroom Helsingis Lasiplatsi, Mannerheimintie 22-24. Sisekujunduse autorid Jan Joonas Graps, Ken-Kristjan Ruut, Anne Määrmann (JanKen Wisespace). Lühidalt loovstuudiost JanKen Wisespace

  14. Applications of thin-film sandwich crystallization platforms.

    Science.gov (United States)

    Axford, Danny; Aller, Pierre; Sanchez-Weatherby, Juan; Sandy, James

    2016-04-01

    Examples are shown of protein crystallization in, and data collection from, solutions sandwiched between thin polymer films using vapour-diffusion and batch methods. The crystallization platform is optimal for both visualization and in situ data collection, with the need for traditional harvesting being eliminated. In wells constructed from the thinnest plastic and with a minimum of aqueous liquid, flash-cooling to 100 K is possible without significant ice formation and without any degradation in crystal quality. The approach is simple; it utilizes low-cost consumables but yields high-quality data with minimal sample intervention and, with the very low levels of background X-ray scatter that are observed, is optimal for microcrystals.

  15. Practical Instruction in Tissue Culture and Cytogenetics for Sandwich Students.

    Science.gov (United States)

    Williams, D. C.; Bishun, N. P.

    1973-01-01

    Describes the training and practical techniques taught to students involved in a sandwich course at the Tissue Culture and Cytogenetics Unit of the Marie Curie Memorial Foundation, Surrey, England. Students spend a minimum of six months involved in the sandwich course before returning to university for a final academic year. (JR)

  16. Non-linear analytical solutions for laterally loaded sandwich plates

    DEFF Research Database (Denmark)

    Riber, Hans Jørgen

    1997-01-01

    This work focuses on the response of orthotropic sandwich composite plates with large deflections due to high lateral loads. The results have special application to the design of ship structures. A geometrical nonlinear theory is outlined, on the basis of the classical sandwich plate theory...

  17. The sandwich sign | Mahomed | SA Journal of Radiology

    African Journals Online (AJOL)

    The sandwich sign refers to the sandwiching of mesenteric vessels and fat by enlarged mesenteric nodes on cross-sectional imaging, commonly occurring in lymphoma, but not specific to lymphoma. The sign is radiologically indistinguishable from post-transplant lymphoproliferative disorders. The radiological significance ...

  18. Non-linear Behavior of Curved Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian; Jolma, P.; Karjalainen, J. P.

    2003-01-01

    In this paper the non-linear behavior of curved sandwich panels is investigated both numerically and experimentally. Focus is on various aspects of finite element modeling and calculation procedures. A simply supported, singly curved, CFRP/PVC sandwich panel is analyzed under uniform pressure load...

  19. Design Analysis of the Mixed Mode Bending Sandwich Specimen

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    . The analysis facilitates selection of the appropriate geometry for the MMB sandwich specimen to promote debond failure. An experimental study is performed using MMB sandwich specimens with a H100 PVC foam core and E-glass–polyester faces. The results reveal that debond propagation is successfully achieved...

  20. Tailoring Sandwich Face/Core Interfaces for Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    Various modifications of the face/core interface in foam core sandwich specimens are examined in a series of two papers. This paper constitutes part I and describes the finite element analysis of a sandwich test specimen, i.e. a DCB specimen loaded by uneven bending moments (DCB-UBM). Using...

  1. Fracture Analysis of Debonded Sandwich Columns Under Axial Compression

    DEFF Research Database (Denmark)

    May, A.; Avilés, F.; Berggreen, Christian

    A sandwich structure consists of two strong and stiff face sheets bonded to a weak low density core. The large separation between the face sheets provides increased bending rigidity and strength at low weight cost. Thus, sandwich structures frequently present better mechanical properties than mon...

  2. Design and manufacturing of bio-based sandwich structures

    CSIR Research Space (South Africa)

    John, Maya J

    2017-03-01

    Full Text Available The aim of this chapter is to discuss the design and manufacturing of bio-based sandwich structures. As the economic advantages of weight reduction have become mandatory for many advanced industries, bio-based sandwich panels have emerged...

  3. Development and evaluation of aerogel-filled BMI sandwich panels for thermal barrier applications

    Directory of Open Access Journals (Sweden)

    A. Dineshkumar

    2016-07-01

    Full Text Available This study details a fabrication methodology envisaged to manufacture Glass/BMI honeycomb core aerogel-filled sandwich panels. Silica aerogel granules are used as core fillers to provide thermal insulation properties with little weight increase. Experimental heat transfer studies are conducted on these panels to study the temperature distribution between their two surfaces. Numerical studies are also carried out to validate the results. Despite exhibiting good thermal shielding capabilities, the Glass/BMI sandwich panels are found to oxidise at 180 ºC if exposed directly to heat. In order to increase the temperature bearing capacity and the operating temperature range for these panels, a way of coating them from outside with high temperature spray paint was tried. With a silicone-based coating, the temperature sustainability of these sandwich panels is found to increase to 350 ºC. This proved the effectiveness of the formed manufacturing process, selected high temperature coating, the coating method as well as the envisaged sandwich panel concept.

  4. Mechanical testing of CFRP materials for application as skins of sandwich composites

    Directory of Open Access Journals (Sweden)

    Adriana STEFAN

    2017-09-01

    Full Text Available Sandwich structures are ultralight materials that are part of a special class and consist of two face skins, that are thin, light and stiff. These materials are of great interest for aeronautical and aerospace applications and they represent one of the important research directions in this field. As skins, a large variety of materials can be used, i.e. aluminium, titanium or polymeric laminates. For the evaluation of sandwich composites based on metallic foam core, a larger study is being currently conducted, one of the objectives within this study being the evaluation of the sandwich system components (CFRP skins developed by two different methods: manual lay-up/room temperature curing and prepreg processing; as well as evaluation of core materials. This paper contains technical work that presents the preliminary results regarding the evaluation of CFRP skins based on CARP/T193 carbon fiber fabric and low viscosity L20 epoxy resin (Diglycidyl Ether of Bisphenol A developed by manual lay-up/room temperature curing. The obtained materials were tested at different mechanical loads and the failure mode was analyzed with the aim to evaluate their performances as possible skins of the sandwich structure with metallic foam core.

  5. Ultra-Lightweight Nanocomposite Foams and Sandwich Structures for Space Structure Applications

    Science.gov (United States)

    Tan, Seng

    2012-01-01

    Microcellular nanocomposite foams and sandwich structures have been created to have excellent electrical conductivity and radiation-resistant properties using a new method that does not involve or release any toxicity. The nanocomposite structures have been scaled up in size to 12 X 12 in. (30 X 30 cm) for components fabrication. These sandwich materials were fabricated mainly from PE, CNF, and carbon fibers. Test results indicate that they have very good compression and compression-after-impact properties, excellent electrical conductivity, and superior space environment durability. Compression tests show that 1000 ESH (equivalent Sun hours) of UV exposure has no effect on the structural properties of the sandwich structures. The structures are considerably lighter than aluminum alloy (= 36 percent lighter), which translates to 36 percent weight savings of the electronic enclosure and its housing. The good mechanical properties of the materials may enable the electronic housing to be fabricated with a thinner structure that further reduces the weight. There was no difficulty in machining the sandwich specimens into electronic enclosure housing.

  6. Deteksi Penyakit Bacterial Fruit Blotch pada Melon Menggunakan ELISA

    Directory of Open Access Journals (Sweden)

    Utik Windari

    2015-07-01

    Full Text Available Bacterial fruit blotch (BFB caused by Acidovorax citrulli is a serious seedborne disease in Cucurbitaceae causing 90-100% yield losses. The aim of this study was to explore BFB symptom on melon and also to detect A. citrulli infection in commercial seed and symptomatic fruits from the field in Yogyakarta Special Region province and its surrounding using DAS-ELISA method. Samples include melon from Sleman, Bantul, Kulon Progo, Gunung Kidul, Magelang, Purworejo regencies while commercial seeds i.e. Action 434, Glamour and Mai 116 were collected. DASELISA detection method used reagent set from Agdia. Based on the field observation, this study found melon commercial fruit shares similar symptom with BFB, which showed discrete oily dark green spots, while the netting failed to develop over necrotic areas, resulting in smooth sunken spots. DAS-ELISA detection revealed that samples collected from Jetak village, district of Mungkid, Magelang and from Bligo village, district of Ngluwar, Magelang and in commercial seed Mai 116 were positively infected by A. citrulli. INTISARI Bacterial fruit blotch (BFB merupakan penyakit penting pada famili Cucurbitaceae yang disebabkan oleh Acidovorax citrulli. Penyakit ini dilaporkan dapat menurunkan hasil mencapai 90-100%. Tujuan dari penelitian ini adalah untuk mengetahui gejala penyakit BFB pada melon dan deteksiA. citrulli pada benih komersial dan sampel buah bergejala dengan metode DAS-ELISA di DIY dan sekitarnya. Pengambilan sampel dilakukan di kabupaten Sleman, Bantul, Kulon Progo, Gunung Kidul, Purworejo dan Magelang. Selain dari lapangan, diuji pula benih melon komersial yaitu Action-434, Glamour dan Mai 116. Metode deteksi dengan ELISA menggunakanreagent set dari Agdia. Dari hasil pengamatan di lapangan ditemukan buah melon dengan gejala yang mirip dengan gejala BFB yaitu adanya becak berwarna hijau tua kebasahan pada permukaan buah, jaring tidak terbentuk sempurna dan pada bagian daging buah di bawah

  7. Cytokinin concentrations in the foliage of spruce trees (Picea abies (L. ) Karst. ) affected to different degrees by 'recently discovered forms of forest disease' as determined in immunoenzymatic assays (ELISA). Der Cytokiningehalt in Nadeln unterschiedlich stark von 'neuartigen Waldschaeden' betroffenen Fichten (Picea abies (L. ) Karst. ), bestimmt mittels einer immunoenzymatischen Methode - ELISA

    Energy Technology Data Exchange (ETDEWEB)

    Schwartzenberg, K. von.

    1989-09-25

    This report attempts to find an answer to the question as to whether the cytokinin concentrations in the leaves of spruce trees showing discolouration or loss of foliage would be any different from those determined for trees, in which no such changes have occurred. Described is a specific analytical method developed for quantitative determinations of the cytokinins trans-zeatin (t-Z), trans-zeatin riboside (t-ZR), isopentenyladenine (ZiP) and isopentenyladenosine (ZiPA). In all, it was found that the levels determined for cytokinin ribosides in needles of the older age groups tested were quite consistent with the degree of discolouration and general damage observed in those trees. Fumigation experiments were additionally performed to find out which effect 8-11 weeks of exposure to an air pollutant, ozone, would have on young spruces. Initial measurements carried out in exposed and non-exposed plants do not yet permit any predictions to be made about the probable influence of ozone on the cytokinin concentrations of foliage. (KST).

  8. Microchip ELISA coupled with cell phone to detect ovarian cancer HE4 biomarker in urine.

    Science.gov (United States)

    Wang, ShuQi; Akbas, Ragip; Demirci, Utkan

    2015-01-01

    Ovarian cancer is a leading cause of death from gynecologic cancers in the USA, and early diagnosis can potentially increase 5-year survival rate. Detection of biomarkers derived from hyperplasia of epithelial tissue by enzyme-linked immunosorbent assay (ELISA) proves to be a practical way of early diagnosis of ovarian cancer. However, ELISA is commonly performed in a laboratory setting, and it cannot be used in a clinical setting for on-site consultation. We have shown a microchip ELISA that detects HE4, an ovarian cancer biomarker, from urine using a cell phone integrated with a mobile application for imaging and data analysis. In microchip ELISA, HE4 from urine was first absorbed on the surface; the primary and secondary antibodies were subsequently anchored on the surface via immuno-reaction; and addition of substrate led to color development because of enzymatic labeling. The microchip after color development was imaged using a cell phone, and the color intensity was analyzed by an integrated mobile application. By comparing with an ELISA standard curve, the concentration of HE4 was reported on the cell phone screen. The presented microchip ELISA coupled with a cell phone is portable as opposed to traditional ELISA, and this method can facilitate the detection of ovarian cancer at the point-of-care (POC).

  9. Application of mimotope peptides of fumonisin b1 in Peptide ELISA.

    Science.gov (United States)

    Liu, Xing; Xu, Yang; He, Qing-hua; He, Zhen-yun; Xiong, Zheng-ping

    2013-05-22

    Anti-fumonisin B(1) (FB(1)) McAb 1D11 was used as the target for biopanning from a phage random loop-constrained heptapeptide library. After three cycles of panning, seven phages with three mimotope peptides were selected to mimic the binding of FB(1) to 1D11. After the identification of phage ELISA, the phage clone that showed the best linear range of detection was chosen for further research. One peptide with the inserted peptide sequence of the phage was synthetized, named CT-452. An indirect competitive ELISA (peptide ELISA) for detecting FB(1) was established using the CT-452-bovine serum albumin conjugate as coating antigen. The linear range of the inhibition curve was 1.77-20.73 ng/mL. The half inhibitory concentration (IC50) was 6.06 ng/mL, and the limit of detection was 1.18 ng/mL. This method was compared with conventional indirect ELISA (commercial ELISA kit) and high-performance liquid chromatography (HPLC), and the results showed the reliability of the peptide ELISA for the determination of FB(1) in cereal samples. The relationship between the CT-452 and FB(1) standard concentrations in peptide ELISA was evaluated. The results indicated that synthetic peptide CT-452 can replace the FB(1) standard to establish an immunoassay free of FB(1).

  10. Validation of an ELISA Synthetic Cannabinoids Urine Assay

    Science.gov (United States)

    Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.

    2015-01-01

    Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046

  11. A Finite Element Analysis for Predicting the Residual Compression Strength of Impact-Damaged Sandwich Panels

    Science.gov (United States)

    Ratcliffe, James G.; Jackson, Wade C.

    2008-01-01

    A simple analysis method has been developed for predicting the residual compression strength of impact-damaged sandwich panels. The method is tailored for honeycomb core-based sandwich specimens that exhibit an indentation growth failure mode under axial compression loading, which is driven largely by the crushing behavior of the core material. The analysis method is in the form of a finite element model, where the impact-damaged facesheet is represented using shell elements and the core material is represented using spring elements, aligned in the thickness direction of the core. The nonlinear crush response of the core material used in the analysis is based on data from flatwise compression tests. A comparison with a previous analysis method and some experimental data shows good agreement with results from this new approach.

  12. A Finite Element Analysis for Predicting the Residual Compressive Strength of Impact-Damaged Sandwich Panels

    Science.gov (United States)

    Ratcliffe, James G.; Jackson, Wade C.

    2008-01-01

    A simple analysis method has been developed for predicting the residual compressive strength of impact-damaged sandwich panels. The method is tailored for honeycomb core-based sandwich specimens that exhibit an indentation growth failure mode under axial compressive loading, which is driven largely by the crushing behavior of the core material. The analysis method is in the form of a finite element model, where the impact-damaged facesheet is represented using shell elements and the core material is represented using spring elements, aligned in the thickness direction of the core. The nonlinear crush response of the core material used in the analysis is based on data from flatwise compression tests. A comparison with a previous analysis method and some experimental data shows good agreement with results from this new approach.

  13. Rapid Enhanced MM3-COPRO ELISA for Detection of Fasciola Coproantigens

    OpenAIRE

    Mart?nez-Sern?ndez, Victoria; Orbegozo-Medina, Ricardo A.; Gonz?lez-Warleta, Marta; Mezo, Mercedes; Ubeira, Florencio M.

    2016-01-01

    ELISA-based methods of detecting Fasciola cathepsins in feces are powerful techniques for diagnosing infections by F. hepatica and F. gigantica. In the last decade, the in-house MM3-COPRO ELISA and its commercial version BIO K 201 (BIO X Diagnostics, Belgium) have been recognized as useful tools for detecting early infections by such trematodes and for monitoring the efficacy of anthelmintic treatments in human and animal species, as they provide some advantages over classic fecal egg counts....

  14. INKRIMINASI NYAMUK ANOPHELES SUBPICTUS SEBAGAI VEKTOR MALARIA DENGAN ELISA DI DAERAH SEKOTONG LOMBOK BARAT

    Directory of Open Access Journals (Sweden)

    Dasuki Dasuki

    2012-11-01

    Full Text Available Malaria is a health-related problem faced by community at West Lombok Regency. One of methods applied in eliminating malaria is vector control. Determination of its method of control requires an understanding on the species of mosquito which serves as the vector and its behavior. ELISA test is a method intended for identifying circum sporozoit Plasmodium at the mosquito body. This research is aimed at incrimination Anopheles subpictus mosquito at West Lombok Regency as malaria vector based onELISA test. Specimen collection is performed by capturing some mosquitoes, that is by adopting landing collection" and "resting collection" inside and outside the house. Female anopheles subpictus mosquito is tested through ELISA test and by applying Writz method 1987. ELISA Test is directed to circum sporozoit, P. falciparum and P. vivax. Result of ELISA Test indicates that Anopheles subpictus mosquito at Sekotong (Sayong and Lendangre are positive on P. falciparum, however, it is negative on P. vivax. of 176 pool samples tested, in which each pool consists of 5 individual, it is obtained the results of 1 positive pools, consisting of 3 pool samples landing collection inside the house, 1 pool sample resting collection inside thehouse and 2 pool samples around cattle. Samples from Lendrangre are 85 pools, it is obtained results of 5 positive pools, consisting of 1 pool sample landing collection outside the house and 4 pool samples aroundcattle. The positive ELISA Specimens are tested and subsequently analyzed by SOFT Program Max PRO3.1.1. ELISA Results of retesting on 11 positive pool samples indicates 9 pool samples, the results are obtained 2,561 sporozoit, while 2 other pool samples are outlier.Keyword: Anopheles subpictus, vector, malaria ELISA.

  15. High Conductive CFRP Sandwich Technologies for Platforms

    Science.gov (United States)

    Ihle, Alexander; Hartmann, D.; Wurfl, T.; Reichmann, O.; Liedtke, V.; Tschepe, C.; Berrill, M.

    2014-06-01

    A general trend in the design of Satellites structures is to use more and more extensively CFRP materials. These materials are lighter, stiffer and have a better dimensional stability than their metallic counterparts. However, the usually used CFRP materials have a low thermal conductivity, which makes the use of these materials difficult if not impossible for all parts that must conduct and distribute heat.For such applications, aluminium skin/core panels are often used for e.g. radiative structure panels. The goal of the study was to design, manufacture and test a CFRP spacecraft sandwich panel structure (based on a shear web supporting dissipative equipments) using high conductive CFRP in order to substitute common aluminium panels.

  16. Validation of an ELISA Synthetic Cannabinoids Urine Assay.

    Science.gov (United States)

    Barnes, Allan J; Spinelli, Eliani; Young, Sheena; Martin, Thomas M; Kleete, Kevin L; Huestis, Marilyn A

    2015-10-01

    Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug-testing laboratories. We evaluated performance of the National Medical Services (NMS) JWH-018 direct enzyme-linked immunosorbent assay (ELISA) kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was used to screen 2492 urine samples with 5 and 10 mcg/L cutoffs. A fully validated liquid chromatography-tandem mass spectrometry method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25% and ±50% of cutoffs determined intraplate and interplate imprecision around proposed cutoffs. The immunoassay was linear from 1 to 500 mcg/L with intraplate and interplate imprecision of ≤8.2% and cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4%, and 97.6%, as well as 71.6%, 99.7%, and 96.4% with the 5 and 10 mcg/L urine cutoffs, respectively. This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5 mcg/L urine cutoff.

  17. Development of ELISA for the detection of transgenic vegetative insecticidal protein in GM crops/produce.

    Science.gov (United States)

    Kumar, R

    2012-01-11

    In the process of the development of insect-resistant genetically modified (GM) crops and also to evaluate the consistency in the expression of toxin under field conditions, immunological assays are commonly being used. An immunoassay was developed to support the labelling of vegetative insecticidal protein (Vip3A)-based GM produce. The developed ELISA for the measurement of Vip3A is a triple antibody sandwich procedure utilising a polyclonal capture antibody (mouse anti-Vip3A) and a polyclonal detection antibody (rabbit anti-Vip3A) followed by use of a third HRP-conjugated anti-species antibody (goat anti-rabbit IgG). The limit of detection limit of the ELISA assay was 16 ng ml(-1) with a linear quantification range from approximately 31 to 500 ng ml(-1) of Vip3A protein. Furthermore, the assay was in-house validated with GM brinjal samples. The assay was specific, sensitive and reproducible, which can be helpful to detect and track down the spread of unapproved and intentionally/unintentionally released GM produce harbouring Vip protein.

  18. Experimental Study of the Bending Properties and Deformation Analysis of Web-Reinforced Composite Sandwich Floor Slabs with Four Simply Supported Edges.

    Science.gov (United States)

    Qi, Yujun; Fang, Hai; Liu, Weiqing

    2016-01-01

    Web-reinforced composite sandwich panels exhibit good mechanical properties in one-way bending, but few studies have investigated their flexural behavior and deformation calculation methods under conditions of four simply supported edges. This paper studies the bending performance of and deformation calculation methods for two-way web-reinforced composite sandwich panels with different web spacing and heights. Polyurethane foam, two-way orthogonal glass-fiber woven cloth and unsaturated resin were used as raw materials in this study. Vacuum infusion molding was used to prepare an ordinary composite sandwich panel and 5 web-reinforced composite sandwich panels with different spacing and web heights. The panels were subjected to two-way panel bending tests with simple support for all four edges. The mechanical properties of these sandwich panels during the elastic stage were determined by applying uniformly distributed loads. The non-linear mechanical characteristics and failure modes were obtained under centrally concentrated loading. Finally, simulations of the sandwich panels, which used the mechanical model established herein, were used to deduce the formulae for the deflection deformation for this type of sandwich panel. The experimental results show that webs can significantly improve the limit bearing capacity and flexural rigidity of sandwich panels, with smaller web spacing producing a stronger effect. When the web spacing is 75 mm, the limit bearing capacity is 4.63 times that of an ordinary sandwich panel. The deduced deflection calculation formulae provide values that agree well with the measurements (maximum error design of this type of panel.

  19. Experimental Study of the Bending Properties and Deformation Analysis of Web-Reinforced Composite Sandwich Floor Slabs with Four Simply Supported Edges.

    Directory of Open Access Journals (Sweden)

    Yujun Qi

    Full Text Available Web-reinforced composite sandwich panels exhibit good mechanical properties in one-way bending, but few studies have investigated their flexural behavior and deformation calculation methods under conditions of four simply supported edges. This paper studies the bending performance of and deformation calculation methods for two-way web-reinforced composite sandwich panels with different web spacing and heights. Polyurethane foam, two-way orthogonal glass-fiber woven cloth and unsaturated resin were used as raw materials in this study. Vacuum infusion molding was used to prepare an ordinary composite sandwich panel and 5 web-reinforced composite sandwich panels with different spacing and web heights. The panels were subjected to two-way panel bending tests with simple support for all four edges. The mechanical properties of these sandwich panels during the elastic stage were determined by applying uniformly distributed loads. The non-linear mechanical characteristics and failure modes were obtained under centrally concentrated loading. Finally, simulations of the sandwich panels, which used the mechanical model established herein, were used to deduce the formulae for the deflection deformation for this type of sandwich panel. The experimental results show that webs can significantly improve the limit bearing capacity and flexural rigidity of sandwich panels, with smaller web spacing producing a stronger effect. When the web spacing is 75 mm, the limit bearing capacity is 4.63 times that of an ordinary sandwich panel. The deduced deflection calculation formulae provide values that agree well with the measurements (maximum error <15%. The results that are obtained herein can provide a foundation for the structural design of this type of panel.

  20. Torsional guided wave-based debonding detection in honeycomb sandwich beams

    Science.gov (United States)

    Zhu, Kaige; Qing, Xinlin P.; Liu, Bin

    2016-11-01

    Debonding is one of the most dangerous damages in honeycomb sandwich structures, which causes stiffness reduction and is invisible from the surface. Guided wave-based non-destructive evaluation is a promising approach with high sensitivity and high efficiency for debonding detection. A torsional guided wave method is proposed to inspect debonding damage in honeycomb sandwich beams, which is proved to be better in damage location for the beams in the paper than the flexural wave used before. The honeycomb heterogeneity effect on the interaction between guided waves and debonding are first investigated by finite element methods. Then the ability of torsional waves to determine debonding locations and sizes is discussed in detail. Finally, in order to verify the proposed method, experiments are carried out to inspect debonding damage with two sizes.

  1. The use of filter paper plasticized with polyvinyl alcohol-glutaraldehyde in ELISA

    Directory of Open Access Journals (Sweden)

    G.H.T.S. Barbosa

    2000-07-01

    Full Text Available F1-antigen purified from Yersinia pestis was covalently linked to 5-mm diameter filter paper discs plasticized with polyvinyl alcohol-glutaraldehyde. These discs were used both for ELISA and dot-ELISA for the detection of anti-F1 IgG in rabbits. The best conditions were achieved using 1.25 µg of F1 antigen/disc, 3% w/v skim milk in PBS as blocking agent, anti-IgG peroxidase conjugate diluted 12,000 times, and serum from rabbits immunized or not against Y. pestis, diluted 6,400 times. The absorbance values obtained from the comparative study between this procedure and conventional ELISA were not significantly different but the low cost of the reagents employed in ELISA using the filter paper discs plasticized with polyvinyl alcohol-glutaraldehyde makes this method economically attractive.

  2. Comparisons of ELISA and Western blot assays for detection of autophagy flux.

    Science.gov (United States)

    Oh, Sung-Hee; Choi, Yong-Bok; Kim, June-Hyun; Weihl, Conrad C; Ju, Jeong-Sun

    2017-08-01

    We analyzed autophagy/mitophagy flux in vitro (C2C12 myotubes) and in vivo (mouse skeletal muscle) following the treatments of autophagy inducers (starvation, rapamycin) and a mitophagy inducer (carbonyl cyanide m-chlorophenylhydrazone, CCCP) using two immunodetection methods, ELISA and Western blotting, and compared their working range, accuracy, and reliability. The ELISAs showed a broader working range than that of the LC3 Western blots (Table 1). Table 2 showed that data value distribution was tighter and the average standard error from the ELISA was much smaller than those of the Western blot, directly relating to the accuracy of the assay. Test-retest reliability analysis showed good reliability for three individual ELISAs (interclass correlation, ≥ 0.7), but poor reliability for three individual Western blots (interclass correlation, ≤ 0.4) (Table 3).

  3. Sandwiched Thin-Film Anode of Chemically Bonded Black Phosphorus/Graphene Hybrid for Lithium-Ion Battery.

    Science.gov (United States)

    Liu, Hanwen; Zou, Yuqin; Tao, Li; Ma, Zhaoling; Liu, Dongdong; Zhou, Peng; Liu, Hongbo; Wang, Shuangyin

    2017-09-01

    A facile vacuum filtration method is applied for the first time to construct sandwich-structure anode. Two layers of graphene stacks sandwich a composite of black phosphorus (BP), which not only protect BP from quickly degenerating but also serve as current collector instead of copper foil. The BP composite, reduced graphene oxide coated on BP via chemical bonding, is simply synthesized by solvothermal reaction at 140 °C. The sandwiched film anode used for lithium-ion battery exhibits reversible capacities of 1401 mAh g-1 during the 200th cycle at current density of 100 mA g-1 indicating superior cycle performance. Besides, this facile vacuum filtration method may also be available for other anode material with well dispersion in N-methyl pyrrolidone (NMP). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A portable and antibody-free sandwich assay for determination of chloramphenicol in food based on a personal glucose meter.

    Science.gov (United States)

    Chen, Si; Gan, Ning; Zhang, Huairong; Hu, Futao; Li, Tianhua; Cui, Huan; Cao, Yuting; Jiang, Qianli

    2015-03-01

    A portable and antibody-free sandwich assay was fabricated for determination of chloramphenicol (CAP) in animal-derived food by a personal glucose meter (PGM). The sandwich-type strategy was developed on the basis of magnetic molecularly imprinted probe (m-MIP) nanoparticles and a β-cyclodextrin/invertase-functionalized signal tag. Firstly, the m-MIPs were fabricated using polydopamine molecularly imprinted film modified Fe3O4 nanoparticles with 2,2-dichloroacetamide as a template that could capture the 2,2-dichloroacetamide segment of CAP. Secondly, β-cyclodextrin/invertase polymer bioconjungate was synthesized as a signal tag that could recognize the nitrobenzene segment of CAP through host-guest interaction. The dual-specificity recognition model relies on the formation of a sandwich between m-MIPs, different segments of CAP, and the β-cyclodextrin-functionalized signal tag. The sandwich-type complex formed was then subjected to detection with a PGM. The complexes can hydrolyze sucrose to glucose, which can be used for detection with a PGM through invertase. According to our experiment, the concentration of CAP was proportional to the amount of glucose formed, which could quantitatively assess the CAP with a dynamic range of 0.5-50 ng mL(-1) and a detection limit of 0.16 ng mL(-1) (signal-to-noise ratio of 3). The detection time of the assay was about 1 h, which was obviously shorter than that of competitive ELISA. More importantly, we have successfully applied this on-site assay for CAP screening in animal-derived food.

  5. Comparison of two competitive ELISAs for the detection of specific ...

    African Journals Online (AJOL)

    GREGO

    2007-03-19

    cELISA PPR antibody test kit. The competitive PPR ELISA (cELISA) test was developed at IAH,. Pirbright by Anderson et al. (1991). This has been developed as a commercial kit supplied by BDSL (UK). This kit uses whole attenuated ...

  6. Sero-epidemiology of Breda virus in cattle using ELISA

    NARCIS (Netherlands)

    Horzinek, M.C.; Koopmans, M.P.; Boom, U. van den; Woode, G.N.

    1989-01-01

    Two direct blocking enzyme linked immunosorbent assays (ELISA) for the detection of antibodies to Breda virus in sera of cattle were compared. An ELISA with consecutive addition of antigen and test serum to an antibody-coated plate gave higher positive: negative absorbence ratios than an ELISA in

  7. Consistency of direct microscopic examination and ELISA in detection of Giardia in stool specimen among children

    Directory of Open Access Journals (Sweden)

    Zohreh Torabi

    2014-09-01

    Full Text Available Objective: To investigate the consistency of direct microscopic examination and ELISA for determination of Giadia in stool specimen. Method: Study population consisted of children with any clinical symptoms of Giardia infestation since last two weeks. Fresh stool specimen was collected from each child. The stools specimens were assessed by two methods of direct microscopic examination and ELISA.The degree of agreement between direct stool exam and ELISA was calculated by Cohen's kappa coefficient. Results: In this study, 124 children with age range 2-12 years were investigated. A total of 64 (61.7% and 79 (65.7% of children had Giardia by direct stool exam and ELISA test respectively. There was association between frequency of constipation and Giardia infection (P=0.036. The Cohen's kappa coefficient calculated for degree of agreement between direct stool exam and ELISA showed κ=0.756 (P<0.001. Conclusions: The frequency of Giardia infection in symptomatic children was high and there was high agreement rate between ELISA and direct stool smear.

  8. Diagnosis of theileria equi infections in horses in the Azores using cELISA and nested PCR

    Science.gov (United States)

    Equine piroplasmosis is a tick-borne disease of equids that is often caused by the parasite Theileria equi. We applied competitive ELISA (cELISA) and nested PCR diagnostic methods to detect this parasite in horses by screening 162 samples from mainland Portugal where the parasite is endemic, and 143...

  9. Validation and implementation of sandwich structure bottom plate to rib weld joint in the base section of ITER Cryostat

    Energy Technology Data Exchange (ETDEWEB)

    Prajapati, Rajnikant, E-mail: rajnikant@iter-india.org [ITER-India, Institute For Plasma Research, A-29, GIDC Electronics Estate, Sector-25, Gandhinagar 382016 (India); Bhardwaj, Anil K.; Gupta, Girish; Joshi, Vaibhav; Patel, Mitul; Bhavsar, Jagrut; More, Vipul; Jindal, Mukesh; Bhattacharya, Avik; Jogi, Gaurav; Palaliya, Amit; Jha, Saroj; Pandey, Manish [ITER-India, Institute For Plasma Research, A-29, GIDC Electronics Estate, Sector-25, Gandhinagar 382016 (India); Jadhav, Pandurang; Desai, Hemal [Larsen & Toubro Limited, Heavy Engineering, Hazira Manufacturing Complex, Gujarat (India)

    2016-11-01

    Highlights: • ITER Cryostat base section sandwich structure bottom plate to rib weld joint is qualified through mock-up. • Established welding sequence was successfully implemented on all six sectors of cryostat base section. • Each layer liquid penetrant examination has been carried out for these weld joints and found satisfactory. - Abstract: Cryostat is a large stainless steel vacuum vessel providing vacuum environment to ITER machine components. The cryostat is ∼30 m in diameter and ∼30 m in height having variable thickness from 25 mm to 180 mm. Sandwich structure of cryostat base section withstands vacuum loading and limits the deformation under service conditions. Sandwich structure consists of top and bottom plates internally strengthened with radial and circular ribs. In current work, sandwich structure bottom plate to rib weld joint has been designed with full penetration joint as per ITER Vacuum Handbook requirement considering nondestructive examinations and welding feasibility. Since this joint was outside the scope of ASME Section VIII Div. 2, it was decided to validate through mock-up of bottom plate to rib joint. Welding sequence was established to control the distortion. Tensile test, macro-structural examination and layer by layer LPE were carried out for validation of this weld joint. However possibility of ultrasonic examination method was also investigated. The test results from the welded joint mock-up were found to confirm all code and specification requirements. The same was implemented in first sector (0–60°) of base section sandwich structure.

  10. Mineralization Induction of Gingival Fibroblasts and Construction of a Sandwich Tissue-Engineered Complex for Repairing Periodontal Defects.

    Science.gov (United States)

    Wu, Mingxuan; Wang, Jie; Zhang, Yanning; Liu, Huijuan; Dong, Fusheng

    2018-02-22

    BACKGROUND The ideal healing technique for periodontal tissue defects would involve the functional regeneration of the alveolar bone, cementum, and periodontal ligament, with new periodontal attachment formation. In this study, gingival fibroblasts were induced and a "sandwich" tissue-engineered complex (a tissue-engineered periodontal membrane between 2 tissue-engineered mineralized membranes) was constructed to repair periodontal defects. We evaluated the effects of gingival fibroblasts used as seed cells on the repair of periodontal defects and periodontal regeneration. MATERIAL AND METHODS Primitively cultured gingival fibroblasts were seeded bilaterally on Bio-Gide collagen membrane (a tissue-engineered periodontal membrane) or unilaterally on small intestinal submucosa segments, and their mineralization was induced. A tissue-engineered sandwich was constructed, comprising the tissue-engineered periodontal membrane flanked by 2 mineralized membranes. Periodontal defects in premolar regions of Beagles were repaired using the tissue-engineered sandwich or periodontal membranes. Periodontal reconstruction was compared to normal and trauma controls 10 or 20 days postoperatively. RESULTS Periodontal defects were completely repaired by the sandwich tissue-engineered complex, with intact new alveolar bone and cementum, and a new periodontal ligament, 10 days postoperatively. CONCLUSIONS The sandwich tissue-engineered complex can achieve ideal periodontal reconstruction rapidly.

  11. Thermal-mechanical behavior of sandwich panels with closed-cell foam core under intensive laser irradiation

    Directory of Open Access Journals (Sweden)

    Li Zhi-Qiang

    2014-01-01

    Full Text Available Temperature field and thermal deformation of sandwich panels with closed-cell aluminum alloy foam core and heat-protective layer, which are subjected to Gaussian laser beam intensively irradiating, are investigated numerically. In transient heat analysis models, the influence of thermal conductivity, specific heat, and thickness of heat-protective layer on the temperature rise of the sandwich panels is calculated. In stress analysis models, a sequence coupled numerical method is utilized to simulate the thermal stress and deformation of sandwich panels induced by thermal expansion. Simulation results indicate that the temperature at center of sandwich panel increases firstly and then drops gradually with the increase of thermal conductivity of heat-protective layer after laser irradiation, and the critical thermal conductivity is obtained, while it decreases with the increase of specific heat and thickness of heat-protective layer. The thermal stress verifies the “Cyclo-hoop effect”, i. e. radial stress is compression stress in “hot zone” and tension stress in “cold zone”. The max thermal deformation of sandwich panels slightly increases with the increase of thickness of heat-protective layer for given specific heat and thermal conductivity.

  12. Enzyme linked immunosorbent assay for rubella antibodies: a simple method of antigen production. A preliminary report Reação imunoenzimática (ELISA para detecção de anticorpos contra o vírus da Rubéola: um método simples de produção de antígeno. Nota prévia

    Directory of Open Access Journals (Sweden)

    Vanda Akico Ueda Fick de Souza

    1995-08-01

    Full Text Available A simple method of rubella antigen production by treatment with sodium desoxycholate for use in enzyme immunoassay (IMT-ELISA is presented. When this assay was compared with a commercial test (Enzygnost-Rubella, Behring, in the study of 108 sera and 118 filter paper blood samples, 96.9% (219/226 overall agreement and correlation coefficient of 0.90 between absorbances were observed. Seven samples showed discordant results, negative by the commercial kit and positive by our test. Four of those 7 samples were available, being 3 positive by HI.Um método simples de produção de antígeno de vírus da rubéola, por extração com desoxicolato de sódio para aplicação no ensaio imunoenzimático, IMT-ELISA, é apresentado. Este ensaio comparado com ELISA comercial (Enzygnost-Rubella, Behring, no estudo de 108 soros e 118 amostras de papel de filtro apresentou 96,9% (219/226 de concordância e um coeficiente de correlação de 0,90 entre as absorbâncias. Sete amostras apresentaram resultados discordantes, negativos pelo ensaio comercial e positivos pelo IMT-ELISA. Destas, 4 foram testadas por RIH, observando-se positividade em 3.

  13. Monoclonal antibody-based serological methods for detecting Citrus tristeza virus in citrus groves.

    Science.gov (United States)

    Liu, Zhen; Chen, Zhe; Hong, Jian; Wang, Xuefeng; Zhou, Changyong; Zhou, Xueping; Wu, Jianxiang

    2016-08-01

    Citrus tristeza virus (CTV) is one of the most economically important citrus viruses and harms the citrus industry worldwide. To develop reliable and effective serological detection assays of CTV, the major capsid protein (CP) gene of CTV was expressed in Escherichia coli BL21 (DE3) using the expression vector pET-28a and purified through Ni+-NTA affinity chromatography. The recombinant protein was used to immunize BALB/c mice. Four hybridoma cell lines (14B10, 14H11, 20D5, and 20G12) secreting monoclonal antibodies (MAbs) against CTV were obtained through conventional hybridoma technology. The titers of MAb-containing ascitic fluids secreted by the four hybridoma lines ranged from 10(-6) to 10(-7) in indirect enzyme-linked immunosorbent assay (ELISA). Western blots showed that all four MAbs could specifically react with CTV CP. Using the prepared MAbs, dot-ELISA, Tissue print-ELISA, and triple antibody sandwich (TAS)-ELISA were developed to detect CTV in tree nurseries and epidemiological studies. The developed dot-ELISA and TAS-ELISA methods could detect CTV in crude extracts of infected citrus leaves with dilutions of 1:2560 and 1:10, 240 (w/v, g/mL), respectively. Tissue print-ELISA was particularly useful for large-scale field sample detection, mainly owing to its simplicity and lack of sample preparation requirements. The field survey revealed that CTV is prevalent on citrus trees in the Chongqing Municipality, Jiangxi Province, and Zhejiang Province of China. The coincidence rate of serological and RT-PCR test results reached more than 99.5%. The prepared MAbs against CTV and established sensitive and specific serological assays have a significant role in the detection and prevention and control of CTV in our country.

  14. EVALUATION OF THE STRUCTURAL BEHAVIOR OF ALUMINUM HONEYCOMB SANDWICH PANELS FOR MICROSATELLITES

    OpenAIRE

    Silva, Hiterson de Oliveira; Andrianov, Artem; Barcelos Júnior, Manuel Nascimento Dias

    2017-01-01

      Abstract. This work has as target the analysis of honeycomb structures by applying analytical models and numerical simulation that employ different finite element approaches: solid model for panel with equivalent honeycomb core properties, solid model of the honeycomb core and faces, and surface model of the honeycomb core and faces. There is also the standard test method for determination of the bending and shear properties of honeycomb sandwich samples whose results are employed for valid...

  15. Enhanced Performance of Sandwich Structures by Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Martakos, Georgios

    up to about 200,000 load cycles, and to assess the effect of high cycle fatigue damage propagation was simulated up to about 2,000,000 load cycles. It was demonstrated that the developed computational methodology is capable of modelling the fatigue behaviour of sandwich structures with embedded peel...... behaviour around the new crack stopper elements. In support for the experimental investigations, a Finite Element (FE) analysis based methodology, including fracture mechanics analysis and the so-called ‘cycle jump’ technique, was developed to predict the progression of damage in sandwich specimens...... with embedded crack stoppers. The starting point for the research was is a new design for a crack stopper, referred to as a ‘peel stopper’, which is proposed for foam cored sandwich structures. Initially, the ability of the peel stopper to prolong the fatigue life of sandwich structures has been demonstrated...

  16. Mechanical and vibro-acoustic aspects of composite sandwich cylinders

    NARCIS (Netherlands)

    Yuan, C.

    2013-01-01

    Designing a fuselage involves many considerations such as strength and stability, fatigue, damage tolerance, fire and lightning resistance, thermal and acoustic insulation, production, inspection, maintenance and repair. In the background of the application of composite sandwich structures on the

  17. Half-sandwich ruthenium, rhodium and iridium complexes of ...

    Indian Academy of Sciences (India)

    sandwich ruthenium, rhodium and iridium complexes of triazolopyridine ligand: Synthesis and structural studies. NARASINGA RAO PALEPU RAO MOHAN KOLLIPARA. Regular Article Volume 129 Issue 2 February 2017 pp 177-184 ...

  18. Standardization and application of indirect plate ELISA for immunodiagnosis of paramphistomosis in ruminants.

    Science.gov (United States)

    Kaur, Shivjot; Singla, L D; Hassan, S S; Juyal, P D

    2009-12-01

    Indirect plate enzyme-linked immunosorbent assay was standardized and evaluated for its effectiveness in immunodiagnosis of paramphistomosis in experimental and clinical cases in sheep, goat, cattle and buffaloes by using somatic whole adult antigen of Paramphistomum epiclitum and Gastrothylax crumenifer. Plate enzymelinked immunosorbent assay (ELISA) was standardized using 2 μg/ml of antigen concentration with 1:200 and 1:1,000 of sera and conjugate dilution. Indirect Plate ELISA was able to demonstrate the antibody titre at different weeks postinfection in experimental sheep. Immune response at weekly interval varied in all the four experimental sheep. A paired t-test between two types of somatic antigens (P. epiclitum and G. crumenifer) showed that experimental sheep sera showed more affinity for homologous antigen as compared to heterologous antigen. A comparison of plate ELISA on suspected field sera and fecal samples examination by sedimentation method revealed that 77 samples were found to be positive by ELISA but only seven by fecal examination. Sensitivity of plate ELISA was found to be 85.71%, whereas specificity was 23.65% indicating that this test is quite sensitive for clinical cases; an early diagnosis, however, lacks specificity. In comparison to ELISA test the sensitivity and specificity of fecal examination were 7.79 and 88%, respectively.

  19. Static and Fatigue Characterization of Nomex Honeycomb Sandwich Panels

    OpenAIRE

    Boualem, Keskes

    2013-01-01

    The main benefits of using the sandwich concept in structural components are the high stiffness, good fatigue resistance and low weight ratios. Recent advances in materials and construction techniques have resulted in further improvement and increased uniformity of the sandwich composite properties. In order to use these materials in different applications, the knowledge of simply their static properties alone is not sufficient but additional information on their fatigue properties and durabi...

  20. Composite Sandwich Structures for Shock Mitigation and Energy Absorption

    Science.gov (United States)

    2016-06-28

    Michelle S. Hoo Fatt Department of Mechanical Engineering College of Engineering Akron, Ohio 44325-3903 Tel: 330-972-6308 Defense Technical...examined. In the second or continuation grant period (July 2014 to Apri I 20 16), the research was extended to address the behavior of composite sandwich...panel theory is based mostly on linear elastic response. This research extended composite sandwich theory by considering the facesheets as anisotropic

  1. Simple Stiffness Tailoring of Balsa Sandwich Core Material

    OpenAIRE

    Kepler, J.A.

    2010-01-01

    Abstract A concept for improving the shear stiffness properties of balsa core material for sandwich structures is presented. The concept is based on utilization of the strongly orthotropic properties of the balsa wood, applying an appropriate transverse layup sequence. The effective core material shear modulus is modeled using basic laminate theory. This is subsequently validated through sandwich beam bending and lap shear experiments. Compared to the standard balsa core systems, a...

  2. Mechanical Property Evaluation of Palm/Glass Sandwiched Fiber Reinforced Polymer Composite in Comparison with few natural composites

    Science.gov (United States)

    Raja Dhas, J. Edwin; Pradeep, P.

    2017-10-01

    Natural fibers available plenty can be used as reinforcements in development of eco friendly polymer composites. The less utilized palm leaf stalk fibers sandwiched with artificial glass fibers was researched in this work to have a better reinforcement in preparing a green composite. The commercially available polyester resin blend with coconut shell filler in nano form was used as matrix to sandwich these composites. Naturally available Fibers of palm leaf stalk, coconut leaf stalk, raffia and oil palm were extracted and treated with potassium permanganate solution which enhances the properties. For experimentation four different plates were fabricated using these fibers adopting hand lay-up method. These sandwiched composite plates are further machined to obtain ASTM standards Specimens which are mechanically tested as per standards. Experimental results reveal that the alkali treated palm leaf stalk fiber based polymer composite shows appreciable results than the others. Hence the developed composite can be recommended for fabrication of automobile parts.

  3. In-situ observation of nucleated polymer crystallization in polyoxymethylene sandwich composites

    Directory of Open Access Journals (Sweden)

    Miroslav eSlouf

    2015-03-01

    Full Text Available We introduce a dynamic sandwich method, which can be used for in-situ observation and quantification of polymer crystallization nucleated by micro/nanoparticles. The method was applied on polyoxymethylene (POM composites with three nucleating agents: talc micropowder (POM/mTalc, chalk nanopowder (POM/nChalk and titanate nanotubes (POM/TiNT. The nucleating agents were deposited between polymer films, the resulting sandwich samples were consolidated by thermal treatment, and their microtomed cross-sections were observed during isothermal crystallization by polarized light microscopy. As the intensity of polarized light was shown to be proportional to the relative crystallinity, the PLM results could be fitted to Avrami equation and the nucleating activity of all investigated particles could be quantified by means of Avrami parameters (n, k. The crystallization half-times increased reproducibly in the following order: POM/nChalk < POM/mTalc < POM/TiNT ~ POM. For strong nucleating agents (mTalc, nChalk, the crystallization kinetics corresponded to spontaneous crystallization starting from central nucleating layer, which was verified by computer simulations. The results were also confirmed by DSC. We concluded that the sandwich method is an efficient microscopic technique for detailed evaluation of nucleating activity of arbitrary micro/nanoparticles in polymer systems.

  4. Sandwich Enzyme-Linked Immunosorbent Assay for Detecting Sesame Seed in Foods.

    Science.gov (United States)

    Koppelman, Stef J; Söylemez, Gülsen; Niemann, Lynn; Gaskin, Ferdelie E; Baumert, Joseph L; Taylor, Steve L

    2015-01-01

    Small amounts of sesame can trigger allergic reactions in sesame-allergic patients. Because sesame is a widely used food ingredient, analytical methods are needed to support quality control and food safety programs in the food industry. In this study, polyclonal antibodies against sesame seed proteins were raised, and an enzyme-linked immunosorbent assay (ELISA) was developed for the detection and quantification of sesame seed residue in food. A comparison was made between this ELISA and other assays, particularly focusing on recovery of sesame seed residue from different food matrices. The developed ELISA is sensitive with a lower limit of quantification of 0.5 ppm and shows essentially no cross-reactivity with other foods or food ingredients (92 tested). The ELISA has a good recovery for analyzing sesame-based tahini in peanut butter, outperforming one other test. In a baked bread matrix, the ELISA has a low recovery, while two other assays perform better. We conclude that a sensitive and specific ELISA can be constructed based on polyclonal antibodies, which is suitable for detection of small amounts of sesame seed relevant for highly allergic patients. Furthermore, we conclude that different food products may require different assays to ensure adequate quantification of sesame.

  5. Sandwich Enzyme-Linked Immunosorbent Assay for Detecting Sesame Seed in Foods

    Directory of Open Access Journals (Sweden)

    Stef J. Koppelman

    2015-01-01

    Full Text Available Small amounts of sesame can trigger allergic reactions in sesame-allergic patients. Because sesame is a widely used food ingredient, analytical methods are needed to support quality control and food safety programs in the food industry. In this study, polyclonal antibodies against sesame seed proteins were raised, and an enzyme-linked immunosorbent assay (ELISA was developed for the detection and quantification of sesame seed residue in food. A comparison was made between this ELISA and other assays, particularly focusing on recovery of sesame seed residue from different food matrices. The developed ELISA is sensitive with a lower limit of quantification of 0.5 ppm and shows essentially no cross-reactivity with other foods or food ingredients (92 tested. The ELISA has a good recovery for analyzing sesame-based tahini in peanut butter, outperforming one other test. In a baked bread matrix, the ELISA has a low recovery, while two other assays perform better. We conclude that a sensitive and specific ELISA can be constructed based on polyclonal antibodies, which is suitable for detection of small amounts of sesame seed relevant for highly allergic patients. Furthermore, we conclude that different food products may require different assays to ensure adequate quantification of sesame.

  6. Wave propagation in and sound transmission through sandwich plates

    Science.gov (United States)

    Nilsson, A. C.

    1990-04-01

    Some dynamical and acoustical properties of sandwich plates are investigated. The types of sandwich elements discussed are three-layered plates with a thick lightweight core, with thin and comparatively stiff laminates bonded to each side of the core. In the model derived it is assumed that the laminates and core are isotropic. The laminates are treated as thin plates, whereas the deflection in the core is described by means of the general field equations. This means that bending shear and rotation, as well as longitudinal deflection, are considered in the core. Wavenumbers, loss factors and apparent bending stiffness for symmetric and asymmetric plates are derived. In addition, the sound transmission loss for sandwich plates is discussed. Measured and predicted results are compared. It is found that bending stiffness and loss factor not only depend on material parameters and plate geometries but also on frequency. The core thickness is very critical for the sound transmission loss of a sandwich plate. Sandwich plates are frequently used in the shipbuilding industry for light and fast passenger vessels. The effects of a fluid load on a sandwich plate is therefore also included.

  7. A novel ELISA test for laboratory diagnosis of Blastocystis spp. in human stool specimens.

    Science.gov (United States)

    Dogruman-Al, Funda; Turk, Songul; Adiyaman-Korkmaz, Gulcan; Hananel, Amit; Levi, Lital; Kopelowitz, June; Babai, Oded; Gross, Shimon; Greenberg, Zvi; Herschkovitz, Yoav; Mumcuoglu, Ipek

    2015-02-01

    Detection of Blastocystis is routinely performed by microscopy, culture, and formyl-ether (ethyl acetate) concentration technique (FECT). Yet, these methods require special skilled personnel, are time consuming, and often involve processing that may cause misdiagnosis. The aim of this work is to demonstrate the usefulness of a newly introduced ELISA test for the detection of Blastocystis antigens in stool samples (CoproELISA(TM) Blastocystis, Savyon Diagnostics) as a proper alternative to currently used methods, especially microscopy. A cohort of 179 fresh/frozen clinical stool samples was tested by the ELISA test, and results were compared to consensus methods comprised of microscopic examination of Lugol's iodine staining, culture, and immunofluorescence assay (IFA). The new ELISA test was able to detect fewer than 10(3) cells, recognized subtypes 1, 2, 3, and 5 (comprising >95 % of human Blastocystis infections), and exhibited similar reactivity when comparing formalin-preserved samples to fresh/frozen samples. The test demonstrated 92 % sensitivity, 87 % specificity, and 89 % accuracy when culture, and IFA or microscopy consensus results were taken as reference. When the consensus was comprised of culture and IFA, the test demonstrated sensitivity, specificity, and accuracy of 82, 86, and 84 %, respectively. In contrast, the sensitivity of Lugol staining microscopy was only 18 %. This work presents a unique ELISA test that provides an alternative to the use of microscopy, currently most widely used method. The test enables high-throughput screening and diagnosis of Blastocystis, adaptation to automatic procedures.

  8. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L.; Smid, B.; Valicek, L.; Jurak, E. (Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia))

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples using ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC.

  9. Diagnosis of Caprine Arthritis Encephalitis Virus infection in dairy goats by ELISA, PCR and Viral Culture.

    Science.gov (United States)

    Panneum, S; Rukkwamsuk, T

    2017-03-01

    For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.

  10. Analysis on spectra of hydroacoustic field in sonar cavity of the sandwich elastic wall structure

    Science.gov (United States)

    Xuetao, W.; Rui, H.; Weike, W.

    2017-09-01

    In this paper, the characteristics of the mechanical self - noise in sonar array cavity are studied by using the elastic flatbed - filled rectangular cavity parameterization model. Firstly, the analytic derivation of the vibration differential equation of the single layer, sandwich elastic wall plate structure and internal fluid coupling is carried out, and the modal method is used to solve it. Finally, the spectral characteristics of the acoustic field of rectangular cavity of different elastic wallboard materials are simulated and analyzed, which provides a theoretical reference for the prediction and control of sonar mechanical self-noise. In this paper, the sandwich board as control inside the dome background noise of a potential means were discussed, the dome background noise of qualitative prediction analysis and control has important theoretical significance.

  11. A new ELISA for the quantification of equine procalcitonin in plasma as potential inflammation biomarker in horses.

    Science.gov (United States)

    Rieger, Martin; Kochleus, Christian; Teschner, Dana; Rascher, Daniela; Barton, Ann Kristin; Geerlof, Arie; Kremmer, Elisabeth; Schmid, Michael; Hartmann, Anton; Gehlen, Heidrun

    2014-09-01

    In human medicine, procalcitonin (PCT) is a very common and well-established biomarker for sepsis. Even though sepsis is also a leading cause of death in foals and adult horses, up to now, no data about the role of equine PCT in septic horses has been available. Based on monoclonal antibodies targeted against human PCT, we report here the development of a sandwich ELISA for the quantification of equine PCT in equine plasma samples. The ELISA was characterized for intra- and interassay variance and a working range from 25 to 1,000 ng mL(-1) was defined as within this range; both intra- and interassay variances were below 15 %. The target recovery ranged between 73 and 106 %. The ELISA was used to determine the equine PCT concentration in 24 healthy and 5 septic horses to show the potential for clinical evaluation of equine PCT. Significantly different (P = 0.0006) mean equine PCT concentrations were found for the healthy control group and the sepsis group (47 and 8,450 ng mL(-1)).

  12. ELISA, a demonstrator environment for information systems architecture design

    Science.gov (United States)

    Panem, Chantal

    1994-01-01

    This paper describes an approach of reusability of software engineering technology in the area of ground space system design. System engineers have lots of needs similar to software developers: sharing of a common data base, capitalization of knowledge, definition of a common design process, communication between different technical domains. Moreover system designers need to simulate dynamically their system as early as possible. Software development environments, methods and tools now become operational and widely used. Their architecture is based on a unique object base, a set of common management services and they host a family of tools for each life cycle activity. In late '92, CNES decided to develop a demonstrative software environment supporting some system activities. The design of ground space data processing systems was chosen as the application domain. ELISA (Integrated Software Environment for Architectures Specification) was specified as a 'demonstrator', i.e. a sufficient basis for demonstrations, evaluation and future operational enhancements. A process with three phases was implemented: system requirements definition, design of system architectures models, and selection of physical architectures. Each phase is composed of several activities that can be performed in parallel, with the provision of Commercial Off the Shelves Tools. ELISA has been delivered to CNES in January 94, currently used for demonstrations and evaluations on real projects (e.g. SPOT4 Satellite Control Center). It is on the way of new evolutions.

  13. Duration of Loxosceles reclusa Venom Detection by ELISA from Swabs

    Science.gov (United States)

    McGLASSON, DAVID L; GREEN, JONATHON A; STOECKER, WILLIAM V; BABCOCK, JAMES L; CALCARA, DAVID A

    2011-01-01

    BACKGROUND Diagnosis of Loxosceles reclusa envenomations is currently based upon clinical presentation. An enzyme-linked immunosorbent assay (ELISA) can detect surface Loxosceles venom at the envenomation site, allowing diagnostic confirmation. The length of time that venom on the skin is recoverable non-invasively is unknown. MATERIALS AND METHODS To investigate duration of recoverable venom antigen, whole venom and fractionated sphingomyelinase D venom aliquots were injected subcutaneously in New Zealand White rabbits. Cotton and Dacron swabs were compared for venom recovery over a 21-day period using a surface swab technique. RESULTS Significant amounts of Loxosceles reclusa antigen were found on the surface of rabbit skin after experimental injection of whole venom and sphingomyelinase D. The duration of recoverable antigen using this experimental model appears to be at least two weeks and as long as 21 days in some cases. CONCLUSIONS Because the duration of the recoverable antigen is seen to be at least two weeks, the ELISA venom test appears capable of detecting venom on most patients presenting with Loxosceles envenomations. This detection system will allow the physician more accurate determination of whether the lesion is from a brown recluse spider or some other agent that can cause this type of necrotic ulcer. PMID:19967916

  14. Shear Behavior of 3D Woven Hollow Integrated Sandwich Composites: Experimental, Theoretical and Numerical Study

    Science.gov (United States)

    Zhou, Guangming; Liu, Chang; Cai, Deng'an; Li, Wenlong; Wang, Xiaopei

    2017-08-01

    An experimental, theoretical and numerical investigation on the shear behavior of 3D woven hollow integrated sandwich composites was presented in this paper. The microstructure of the composites was studied, then the shear modulus and load-deflection curves were obtained by double lap shear tests on the specimens in two principal directions of the sandwich panels, called warp and weft. The experimental results showed that the shear modulus of the warp was higher than that of the weft and the failure occurred in the roots of piles. A finite element model was established to predict the shear behavior of the composites. The simulated results agreed well with the experimental data. Simultaneously, a theoretical method was developed to predict the shear modulus. By comparing with the experimental data, the accuracy of the theoretical method was verified. The influence of structural parameters on shear modulus was also discussed. The higher yarn number, yarn density and dip angle of the piles could all improve the shear modulus of 3D woven hollow integrated sandwich composites at different levels, while the increasing height would decrease the shear modulus.

  15. Sensitive sandwich immunoassay based on single particle mode inductively coupled plasma mass spectrometry detection.

    Science.gov (United States)

    Liu, Rui; Xing, Zhi; Lv, Yi; Zhang, Sichun; Zhang, Xinrong

    2010-11-15

    A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis). The signal induced by the flash of ions ((197)Au(+)) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer. The frequency of the transient signals is proportional to the concentration of Au-NPs labels. Characteristics of the signals obtained from Au-NPs of 20, 45 and 80 nm in diameters were discussed. The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail. Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay. A detection limit (3 σ) of 0.1 ng mL(-1) was obtained for rabbit-anti-human IgG after immunoreactions, with a linear range of 0.3-10 ng mL(-1) and a RSD of 8.1% (2.0 ng mL(-1)). Finally, the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples. The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Flexible freestanding sandwich type ZnO/rGO/ZnO electrode for wearable supercapacitor

    Science.gov (United States)

    Ghorbani, Mina; Golobostanfard, Mohammad Reza; Abdizadeh, Hossein

    2017-10-01

    The development of flexible supercapacitors with high energy and power density as one of the main components of wearable electronics is in an enormous interest. In this report, a unique flexible electrode based on freestanding sandwich type ZnO/rGO/ZnO paper is fabricated by a simple low cost sol-gel method for utilizing in flexible supercapacitor. ZnO layers are deposited on both sides of rGO paper which is prepared by a modified Hummer's method and evaporation induced assembly. The uniform and densely packed ZnO layers are formed on graphene oxide paper and the paper is simultaneously reduced. Structural analysis reveals the formation of ZnO thin films on both sides of rGO nanosheets, which leads to the sandwich architecture. Also, the effect of ZnO sol-gel process parameters on microstructure of sandwich paper are investigated and the most suitable condition for highest supercapacity performance is the solvent of 1-PrOH, stabilizer of TeA, sol concentration of 0.2 M, deposition speed of 30 mm min-1, and 10 deposited layers. The results of electrochemical impedance spectroscopy, galvanostatic charge-discharge, and cyclic voltammetry confirm that the incorporation of ZnO improves the capacitive performance of rGO electrode. Moreover, ZnO/rGO/ZnO flexible electrode exhibits suitable capacitance value of 60.63 F g-1 at scan rate of 5 mV/s.

  17. Effects of a Proline Endopeptidase on the Detection and Quantitation of Gluten by Antibody-Based Methods during the Fermentation of a Model Sorghum Beer.

    Science.gov (United States)

    Panda, Rakhi; Fiedler, Katherine L; Cho, Chung Y; Cheng, Raymond; Stutts, Whitney L; Jackson, Lauren S; Garber, Eric A E

    2015-12-09

    The effectiveness of a proline endopeptidase (PEP) in hydrolyzing gluten and its putative immunopathogenic sequences was examined using antibody-based methods and mass spectrometry (MS). Based on the results of the antibody-based methods, fermentation of wheat gluten containing sorghum beer resulted in a reduction in the detectable gluten concentration. The addition of PEP further reduced the gluten concentration. Only one sandwich ELISA was able to detect the apparent low levels of gluten present in the beers. A competitive ELISA using a pepsin-trypsin hydrolysate calibrant was unreliable because the peptide profiles of the beers were inconsistent with that of the hydrolysate calibrant. Analysis by MS indicated that PEP enhanced the loss of a fragment of an immunopathogenic 33-mer peptide in the beer. However, Western blot results indicated partial resistance of the high molecular weight (HMW) glutenins to the action of PEP, questioning the ability of PEP in digesting all immunopathogenic sequences present in gluten.

  18. Standardization and in-house ELISA setup for helicobacter pylori serologic diagnosis

    Directory of Open Access Journals (Sweden)

    Shahrestani T

    2001-09-01

    Full Text Available Helicobacter pylori (H.pylori is the most prominent causative agent of gastroduodenal diseases all over the world. Other manifestations such as urticaria and coronary heart diseases, also are suspected to be induced by H.pylori. Non invasive methods are preferred for diagnosis; and ELISA, because of its reliability, speed, sensitivity and specificity is widely preferred as diagnostic tool. Previously we have used IFA, and here, we report an indirect ELISA technique for H.pylori diagnosis. First, 9 strains, of H.pylori isolated from biopsies, were cultured, and the soluble crude antigen was used to coat ELISA plates. Antigen concentration and conjugated antiserum dilution were optimised using checker board method. In this study the gold standard was: rapid urease test, culture and direct smear. Patient serum dillution and the cut-off value was determind, using 22 negative and 30 positive confirmed samples according to ROC curve and the results were compared with a commercial kit. The sensitivity and specificity of this method were 93.2 percent and 95.4 percent respectively. A commercial ELISA Kit, was used and compared simultaneously. The sensitivity and specificity were 87.8 percent and 73 percent respectively. Therefore, regarding the acceptable sensitivity and specificity, ease of work of ELISA, being economical and non-invasive, it can be employed in diagnosis of H.pylori infection and also in epidemiological studies.

  19. Determination of Peroxide Value of Edible Oils Used in Confectionary, Restaurants and Sandwich Shops in Gorgan in 2011

    Directory of Open Access Journals (Sweden)

    H RahimzadehBarzoki

    2014-05-01

    Conclusion: The findings show that Peroxide value in sandwich and fast food shops, restaurants, and confectionary shop are higher than the standard, so its seems that having educational plan for staff about nutrition and the correct methods of frying food is necessary.

  20. Comparative Evaluation of RUT, PCR and ELISA Tests for Detection of Infection with Cytotoxigenic H. pylori.

    Science.gov (United States)

    Jalalypour, Farzaneh; Farajnia, Safar; Somi, Mohammad Hossein; Hojabri, Zoya; Yousefzadeh, Rana; Saeedi, Nazli

    2016-06-01

    Helicobacter pylori is one of the most prevalent infectious agents in the world which causes a variety of gastrointestinal diseases including gastritis, peptic ulcer and gastric carcinoma. The objective of this study was to comparatively evaluate invasive (rapid urease test and polymerase chain reaction) and non-invasive (enzyme-linked immunosorbent assay) tests in diagnosis of infection with cytotoxigenic H. pylori. Biopsy specimens and sera were collected from 105 patients with gastric disorders. The presence of H. pylori infection in gastric biopsies was evaluated by RUT and PCR methods using chemotaxis signal transduction protein gene (CSTP), Urea C and HP-16srRNA primers. Serum samples were used for the ELISA test. Detection of infection with cag A-positive strains was performed by PCR and cag A-IgG ELISA kit. Patients with at least two out of three positive results were regarded as infected. The sensitivity, specificity, predictive value and accuracy of the three different methods were evaluated. Of the 105 gastric biopsies, H. pylori were positive in 51 patients (48.57%). The best sensitivity (92.16%) belonged to RUT. The sensitivities of other tests including PCR and ELISA test were 88.24% and 90.20%, respectively. PCR showed the best specificity (94.44%), and the specificities of the other tests including RUT and ELISA test, were 90.74 % and 61.11%, respectively. Furthermore, results of PCR and cag A-IgG ELISA showed high prevalence of cag A-positive strain in the study population. Based on our findings, serum ELISA is a rapid noninvasive test for screening of H. pylori infection in the absence of endoscopy indication. In addition, considering the high prevalence of cytotoxigenic H. pylori strains, cag A is suggested as a promising target for PCR and non- invasive ELISA tests for detection of infection with toxigenic strains.

  1. Development of a Fibrinogen-Specific Sandwich Enzyme-Linked Immunosorbent Assay Microarray Assay for Distinguishing Between Blood Plasma and Serum Samples

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, Rachel M.; Zhang, Qibin; Zangar, Richard C.; Smith, Richard D.; Metz, Thomas O.

    2011-07-01

    We have developed a fibrinogen-specific sandwich ELISA microarray assay for use in qualitatively distinguishing between blood plasma and serum samples. Three capture antibodies, 49D2, HPA001900, and F8512, were evaluated in conjunction with 1D6 as detection antibody, and the data show that 49D2 and, to a lesser extent, F8512 successfully identify previously unknown plasma and serum samples based upon a ~28-fold difference in signal intensity between the sample types. This assay has utility in rapidly identifying previously archived clinical samples with incomplete annotation in a high throughput manner prior to proteomics analyses.

  2. Evaluating concentration estimation errors in ELISA microarray experiments

    OpenAIRE

    Anderson Kevin K; Varnum Susan M; White Amanda M; Daly Don; Zangar Richard C

    2005-01-01

    Abstract Background Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to estimate a protein's concentration in a sample. Deploying ELISA in a microarray format permits simultaneous estimation of the concentrations of numerous proteins in a small sample. These estimates, however, are uncertain due to processing error and biological variability. Evaluating estimation error is critical to interpreting biological significance and improving the ELISA microarray process. Estimatio...

  3. Mechanical behavior of a sandwich with corrugated GRP core: numerical modeling and experimental validation

    Directory of Open Access Journals (Sweden)

    D. Tumino

    2014-10-01

    Full Text Available In this work the mechanical behaviour of a core reinforced composite sandwich structure is studied. The sandwich employs a Glass Reinforced Polymer (GRP orthotropic material for both the two external skins and the inner core web. In particular, the core is designed in order to cooperate with the GRP skins in membrane and flexural properties by means of the addition of a corrugated laminate into the foam core. An analytical model has been developed to replace a unit cell of this structure with an orthotropic equivalent thick plate that reproduces the in plane and out of plane behaviour of the original geometry. Different validation procedures have been implemented to verify the quality of the proposed method. At first a comparison has been performed between the analytical model and the original unit cell modelled with a Finite Element mesh. Elementary loading conditions are reproduced and results are compared. Once the reliability of the analytical model was assessed, this homogenised model was implemented within the formulation of a shell finite element. The goal of this step is to simplify the FE analysis of complex structures made of corrugated core sandwiches; in fact, by using the homogenised element, the global response of a real structure can be investigated only with the discretization of its mid-surface. Advantages are mainly in terms of time to solution saving and CAD modelling simplification. Last step is then the comparison between this FE model and experiments made on sandwich beams and panels whose skins and corrugated cores are made of orthotropic cross-ply GRP laminates. Good agreement between experimental and numerical results confirms the validity of the proposed model.

  4. Three different signal amplification strategies for the impedimetric sandwich detection of thrombin

    Energy Technology Data Exchange (ETDEWEB)

    Ocaña, Cristina; Valle, Manel del, E-mail: manel.delvalle@uab.cat

    2016-03-17

    In this work, we report a comparative study on three highly specific amplification strategies for the ultrasensitive detection of thrombin with the use of aptamer sandwich protocol. The protocol consisted on the use of a first thrombin aptamer immobilized on the electrode surface, the recognition of thrombin protein, and the reaction with a second biotinylated thrombin aptamer forming the sandwich. Through the exposed biotin end, three variants have been tested to amplify the electrochemical impedance signal. The strategies included (a) silver enhancement treatment, (b) gold enhancement treatment and (c) insoluble product produced by the combination of the enzyme horseradish peroxidase (HRP) and 3-amino-9-ethylcarbazole (AEC). The properties of the sensing surface were probed by electrochemical impedance measurements in the presence of the ferrocyanide/ferricyanide redox marker. Insoluble product strategy and silver enhancement treatment resulted in the lowest detection limit (0.3 pM), while gold enhancement method resulted in the highest reproducibility, 8.8% RSD at the pM thrombin concentration levels. Results of silver and gold enhancement treatment also permitted direct inspection by scanning electron microscopy (SEM). - Highlights: • Aptasensor to detect thrombin reaching the femtomolar level. • Biosensing protocol employs two thrombin aptamers in a sandwich capture scheme. • Use of second biotinylated aptamer allows many amplification and detection variants. • Precipitation reaction provides the highest signal amplification of ca. 3 times. • Double recognition event improves remarkably selectivity for thrombin detection.

  5. Lamb wave-based BVID imaging for a curved composite sandwich panel

    Science.gov (United States)

    He, Jiaze; Yuan, Fuh-Gwo

    2017-02-01

    Composite sandwich structures, consisting of a low density core sandwiched between two laminated facesheets, have been widely used in various aerospace structures. A new Lamb wave-based imaging condition, which will be referred to as the inverse incident wave energy (IIWE) imaging criterion, is proposed in this paper to resolve the situations where the incident wave energy weakly penetrates into the damaged area in the upper facesheet region. Current imaging conditions by analyzing wavefield reconstructed from laser Doppler vibrometer (LDV) scanning have been proven to be adequate for imaging damage in layered composite laminates. In this research, those current imaging conditions were applied and compared in the composite foam structures for barely visible impact damage (BVID). A piezoelectric wafer was used to excite Lamb waves into the structure and a LDV was used to scan the potential damaged areas in the upper facesheet of the panel. A BVID site in a curved composite sandwich foam aileron was inspected using various wavefield analysis methods and the damage images were compared with C-scan images. A few imaging conditions that are effective for this BVID site are identified when the incident waves have difficulties penetrating into the damaged region.

  6. Nanometric self-assembling peptide layers maintain adult hepatocyte phenotype in sandwich cultures

    Directory of Open Access Journals (Sweden)

    Borrós Salvador

    2010-12-01

    Full Text Available Abstract Background Isolated hepatocytes removed from their microenvironment soon lose their hepatospecific functions when cultured. Normally hepatocytes are commonly maintained under limited culture medium supply as well as scaffold thickness. Thus, the cells are forced into metabolic stress that degenerate liver specific functions. This study aims to improve hepatospecific activity by creating a platform based on classical collagen sandwich cultures. Results The modified sandwich cultures replace collagen with self-assembling peptide, RAD16-I, combined with functional peptide motifs such as the integrin-binding sequence RGD and the laminin receptor binding sequence YIG to create a cell-instructive scaffold. In this work, we show that a plasma-deposited coating can be used to obtain a peptide layer thickness in the nanometric range, which in combination with the incorporation of functional peptide motifs have a positive effect on the expression of adult hepatocyte markers including albumin, CYP3A2 and HNF4-alpha. Conclusions This study demonstrates the capacity of sandwich cultures with modified instructive self-assembling peptides to promote cell-matrix interaction and the importance of thinner scaffold layers to overcome mass transfer problems. We believe that this bioengineered platform improves the existing hepatocyte culture methods to be used for predictive toxicology and eventually for hepatic assist technologies and future artificial organs.

  7. LISA Pathfinder and eLISA news

    Science.gov (United States)

    Thorpe, James Ira; Mueller, Guido

    2014-01-01

    Two important gatherings of the space-based gravitational-wave detector community were held in Zurich, Switzerland this past March. The first was a meeting of the Science Working Team for LISA Pathfinder (LPF), a dedicated technology demonstrator mission for a future LISA-like gravitational wave observatory. LPF is entering an extremely exciting phase with launch less than 15 months away. All flight components for both the European science payload, known as the LISA Technology Package (LTP), and the NASA science payload, known as the Space Technology 7 Disturbance Reduction System (ST7-DRS), have been delivered and are undergoing integration. The final flight component for the spacecraft bus, a cold-gas thruster based on the successful GAIA design, will be delivered later this year. Current focus is on completing integration of the science payload (see Figures 1 and 2) and preparation for operations and data analysis. After a launch in Summer 2015, LPF will take approximately 90 days to reach its operational orbit around the Earth-Sun Lagrange point (L1), where it will begin science operations. After 90 days of LTP operations followed by 90 days of DRS operations, LPF will have completed its prime mission of paving the way for a space-based observatory of gravitational waves in the milliHertz band. Immediately following the meeting of the LPF team, the eLISA consortium held its third progress meeting. The consortium (www.elisascience.org) is the organizing body of the European space-based gravitational-wave community, and it was responsible for the "The Gravitational Universe" whitepaper that resulted in the November 2013 election of a gravitational-wave science theme for ESA's Cosmic Visions L3 opportunity. In preparation for an L3 mission concept call, which is expected later this decade, and for launch in the mid 2030s, the eLISA consortium members are coordinating technology development and mission study activities which will build on the LPF results. The final

  8. Detection of norovirus infections in Canakkale with ELISA and RT-PCR

    Directory of Open Access Journals (Sweden)

    Arif Aksu

    2016-09-01

    Full Text Available Purpose: Noroviruses are important agents of gastroenteritis worldwide in every age group. There is no large countrywide dataset available for norovirus infections in Turkey. This is the first investigation of noroviruses in Canakkale, and we aimed to compare commercial ELISA and real time RT-PCR assays in clinical use. Material and Methods: Fecal samples from 92 clinical gastroenteritis cases were collected and stored at -20 and deg;C. Norovirus antigen was investigated using RidaScreen ELISA and norovirus GI and GII molecular detection made with RealStar Norovirus RT-PCR kit 2.0. Results: We found that 16 (17.4% samples were positive for norovirus in our study group. Using ELISA, 10 samples were positive from 92 samples. In PCR analysis, internal control amplification failed for four samples. We found 15 of 88 samples positive for real time RT-PCR analysis; of these one was GI and 14 were GII. When we accepted PCR as the reference test, the sensitivity and specificity of ELISA were calculated as 60% and 98% respectively. Conclusion: Single cases of norovirus infection can be seen even in rural cities like Canakkale. There is a need to set up diagnostic capabilities for norovirus infections. ELISA has a low sensitivity, but this method is cheaper than RT-PCR and is not affected by PCR inhibitors. [Cukurova Med J 2016; 41(3.000: 533-538

  9. Performance of microscopy and ELISA for diagnosing Giardia duodenalis infection in different pediatric groups.

    Science.gov (United States)

    Silva, Renata K N R; Pacheco, Flávia T F; Martins, Adson S; Menezes, Joelma F; Costa-Ribeiro, Hugo; Ribeiro, Tereza C M; Mattos, Ângela P; Oliveira, Ricardo R; Soares, Neci M; Teixeira, Márcia C A

    2016-12-01

    Techniques for Giardia diagnosis based on microscopy are usually applied as routine laboratory testing; however, they typically exhibit low sensitivity. This study aimed to evaluate Giardia duodenalis and other intestinal parasitic infections in different pediatric groups, with an emphasis on the comparison of Giardia diagnostic techniques. Feces from 824 children from different groups (diarrheic, malnourished, with cancer and from day care) were examined by microscopy and ELISA for Giardia, Cryptosporidium sp. and Entamoeba histolytica coproantigen detection. Giardia-positive samples from day-care children, identified by either microscopy or ELISA, were further tested by PCR targeting of the β-giardin and Gdh genes. Statistically significant differences (Pmicroscopy (97% versus 55%). To examine discrepancies among the diagnostic methods, 71 Giardia-positive stool samples from day-care children were tested by PCR; of these, DNA was amplified from 51 samples (77.4%). Concordance of positivity between microscopy and ELISA was found for 48 samples, with 43 confirmed by PCR. Parasite DNA was amplified from eleven of the 20 Giardia samples (55%) identified only by ELISA. This study shows the higher sensitivity of ELISA over microscopy for Giardia diagnosis when a single sample is analyzed and emphasizes the need for methods based on coproantigen detection to identify this parasite in diarrheic fecal samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. His-tag ELISA for the detection of humoral tumor-specific immunity

    Directory of Open Access Journals (Sweden)

    Disis Mary L

    2008-05-01

    Full Text Available Abstract Background The application of high throughput molecular techniques such as SEREX are resulting in the identification of a multitude of tumor associated antigens. As newly identified antigens are incorporated into a variety of clinical trials, standardization of immunologic monitoring methods becomes increasingly important. We questioned whether mammalian cell expression of a histadine-linked human protein could be used to produce antigen suitable for detecting tumor-specific humoral immunity and whether such an assay could be amenable to standardization for clinical use. Methods We designed a his-tagged capture ELISA based on lysate from genetically engineered CHO cells for detection of antibodies to insulin-like growth factor binding protein 2, a novel tumor antigen. We performed technical and preliminary clinical validation studies, including comparison to a standard indirect ELISA based on commercially prepared recombinant antigen. Results The his-tagged capture ELISA could be standardized. Precision experiments resulted in CVs 2 values of 0.99. In comparison to Western blot analysis, his-tag and indirect ELISA accurately identified 88% and 93% of samples, respectively. Sample concordance between capture and indirect assays was highly significant (p = 0.003. Furthermore, significantly greater levels of IGFBP-2 antibody immunity were found in cancer patients compared to normal controls (p = 0.008. Conclusion A genetically engineered cell lysate based ELISA can be amenable to standardization and can detect increased levels of antibody immunity to tumor-associated antigen in cancer patients compared to non tumor-bearing healthy controls.

  11. Piezoelectric performance of fluor polymer sandwiches with different void structures

    Science.gov (United States)

    Lou, Kexing; Zhang, Xiaoqing; Xia, Zhongfu

    2012-06-01

    Film sandwiches, consisting of two outer layers of fluoroethylenepropylene and one middle layer of patterned porous polytetrafluoroethylene, were prepared by patterning and fusion bonding. Contact charging was conducted to render the films piezoelectric. The critical voltage to trigger air breakdown in the inner voids in the fabricated films was investigated. The piezoelectric d 33 coefficients were measured employing the quasistatic method and dielectric resonance spectrum. The results show that the critical voltage for air breakdown in the inner voids is associated with the void microstructure of the films. For the films with patterning factors of 0%, 25% and 44%, the critical values are 300, 230 and 230 kV/cm, respectively. With an increase in the patterning factor, both the piezoelectric d 33 coefficients determined from the dielectric resonance spectra and those determined from quasistatic measurements increase, which might be due to a decrease in Young's modulus for the films. The nonlinearity of d 33 becomes increasingly obvious as the patterning factor increases.

  12. Investigation of Entamoeba histolytica in stool specimens by ELISA during a year

    Directory of Open Access Journals (Sweden)

    Mehmet Sinan Dal

    2011-03-01

    Full Text Available The aim of this study was to investigate Entamoebahistolytica in the stool samples that have beensent to microbiology laboratory by ELISA method.Materials and methods: This study was performed on800 stool specimens belonging to different age groupsand different patients sent to Microbiology Laboratory ofa State Hospital between January 2009 and December2009.Results: In this study Entamoeba histolytica/dispar cystsand/or trophozoites were observed in 31 (3.9% out of atotal of 800 stool specimens which were examined bynative-lugol. Entamoeba histolytica specific antigen wasinvestigated by ELISA in all stool specimens. Entamoebahistolytica specific antigen was detected in 12 (1.5% ofthese stool specimens. The diagnosis of amoebiasis forthe patients whose ELISA tests were “positive” and appropriatetherapy was begun.Conclusion: Entamoeba histolytica in the stool samplesshould be investigated and unnecessary treatmentsshould not given to patients. J Clin Exp Invest 2011; 2(1:50-54

  13. Interface fatigue crack propagation in sandwich X-joints – Part II: Finite element modeling

    DEFF Research Database (Denmark)

    Moslemian, Ramin; Berggreen, Christian

    2013-01-01

    The aim of the second and final part of this study is to simulate fatigue crack growth in the tested Sandwich Tear Test specimens, described in Part I, using the finite element method. To accelerate the simulation, a cycle jump method is utilized and implemented in the finite element routine....... The proposed method is based on conducting finite element analysis for a set of cycles to establish a trend line, extrapolating the trend line spanning many cycles, and use the extrapolated state as initial state for additional finite element simulations. The measured da/dN relations of the face/core interface...

  14. Quantum confinement in multi-nanolayer sandwich systems

    Science.gov (United States)

    Khmelinskii, Igor; Makarov, Vladimir I.

    2017-11-01

    Presently we explored quantum confinement (QC) in three-nanolayer sandwich systems, composed of Au-SnO2-Fe, Au-SnO2-Si and Au-SnO2-Ag layers. We recorded the absorption spectra of these sandwich systems, all with discrete structure. We recorded the action spectra of the photocurrent for the Au-SnO2-Fe sandwich system, with the photocurrent quantum yields increasing with the photon energy, achieving 3.1 at 4.7 × 104 cm-1. The photocurrent action spectra correlate with high accuracy with optical absorption spectra. We discuss the mechanisms determining the absorption bandwidth value, including surface imperfections, thermal distribution of the vibrational level populations in the electronic ground state, and the diabatic coupling of levels of the excited state to those of a ;dark; state. Volt-Ampere (V/A) characteristics were recorded for all three of the sandwich systems, quite similar to those of a Schottky diode. We report the parameter values of the V/A characteristics, found by fitting the experimental data with a theoretical curve. We also report charge density changes in the SnO2 layer caused by low constant voltage applied to the sandwich structure, observed as changes in the absorption band intensity.

  15. Detección de antígenos de la larva de Taenia solium mediante la Técnica de Elisa

    Directory of Open Access Journals (Sweden)

    Carmenza Murillo

    2010-07-01

    Full Text Available Se describe la optimización de las variables en un ELISA sandwich asimétrico para la detección de antígenos circulantes de larva de Taenia solium empleado como estándar líquido intraquístico obtenido del parásito y como suero itunune anticisticerco absorbido con líquido cefalorraquídeo (LCR normal lo que permite detectar 50 ng/ mi de antígeno. Se utilizaron muestras de LCR liofilizadas; bajo estas condiciones de almacenamiento la especificidad obtenida fue del 63% al analizar 24 LCR negativos para neurocisticercosis por tromografía computarizada cerebral, y 15 LCR de pacientes que mostraban calcificaciones. El coeficiente de variación interensayo está dentro de los límites aceptados para el ELISA.

  16. Padronização da técnica imunoenzimática do ELISA de captura, no sistema avidina-biotina para a identificação de sangue ingerido por Lutzomyia (Lutzomyia longipalpis (Lutz & Neiva, 1912 Enzyme-linked Immunosorbent Assay biotin/avidin method standardization, for identification of Lutzomyia (Lutzomyia longipalpis bloodmeals (Lutz & Neiva, 1912

    Directory of Open Access Journals (Sweden)

    Ana Maria Marassá

    2004-12-01

    Full Text Available A identificação de sangue ingerido pelos insetos é um importante parâmetro para elucidar aspectos ligados à transmissão de zoonoses, dentre elas, as leishmanioses. Dos métodos empregados para esclarecer a atração de vetores por animais que possam atuar como reservatórios dessas parasitoses, destacam-se os imunológicos. O estudo teve como objetivo, padronizar a técnica imunoenzimática de captura e titular amostras de sangue ingerido em fêmeas de flebotomíneos ingurgitadas de Lutzomyia longipalpis criadas em laboratório e alimentadas experimentalmente em rato. Em vista da alta sensibilidade, favorecida pelo sistema avidina-biotina, foi possível a realização de pelo menos noventa testes, de cada uma das amostras em duplicata, e constatar a presença de sangue para todas as amostras com períodos de 12 e 24 horas pós-ingestão, observando-se diferença significativa entre os respectivos títulos.Bloodmeals taken by insects constitute an important parameter for clarifying aspects of the transmission of zoonoses, including leishmaniases. Immunological assays can be used to investigate the attraction of vectors to animals, which may be hosts of these parasitoses. The objective of this study was to standardize a sandwich enzyme-linked immunosorbent assay and titer samples with different time periods of digestion, in laboratory-bred Lutzomyia longipalpis fed on rats. In the light of the high sensitivity that the biotin-avidin method permits, the technique provided at least ninety repeat tests for each sample and identified recent bloodmeals taken by these insects. Bloodmeals were detectable up to 12 and 24h after blood ingestion, and a significant difference between these titers was observed.

  17. Improvement Noise Insulation Performance of Polycarbonate Pane using Sandwich Structure

    Science.gov (United States)

    Shen, Min; Nagamura, Kazuteru; Nakagawa, Noritoshi; Okamura, Masaharu

    Polycarbonate (PC) laminates offer the possibility of designing strong and light weight panes application in automobile. However, the noise insulation performance of PC pane is worse than glass pane because of its high rate of stiffness to low weight. In this work, a new ultra-thin(less than 10mm) sandwich pane is proposed to obtain high transmission loss(TL). The sandwich structure consists of two thin laminates plates of the same PC material and a thin lightweight damping core bonded between those plates. Then TL is predicted using decoupled equations representing symmetric and anti-symmetric motions for a sandwich PC pane. The effects of various structural and material parameters on noise insulation performance are investigated with numerical examples. Numerical results show that the shear rigidity has evident effect on coincidence frequency and proposed structure has better noise insulation properties than single layer PC pane of equivalent thickness.

  18. Identification of material properties of sandwich structure with piezoelectric patches

    Directory of Open Access Journals (Sweden)

    Zemčík R.

    2008-11-01

    Full Text Available The work focuses on light-weight sandwich structures made of carbon-epoxy skins and foam core which have unique bending stiffness compared to conventional materials. The skins are manufactured by vacuum autoclave technology from unidirectional prepregs and the sandwich is then glued together. The resulting material properties of the structure usually differ from those provided by manufacturer or even those obtained from experimental tests on separate materials, which makes computational models unreliable. Therefore, the properties are identified using the combination of experimental analysis of the sandwich with attached piezoelectric transducer and corresponding static and modal finite element analyses. Simple mathematical optimization with repetitive finite element solution is used. The model is then verified by transient analysis when the piezoelectric patch is excited by harmonic signals covering the first two eigen-frequencies and the induced oscillations are measured by laser sensor.

  19. Nanocrystalline Aluminum Truss Cores for Lightweight Sandwich Structures

    Science.gov (United States)

    Schaedler, Tobias A.; Chan, Lisa J.; Clough, Eric C.; Stilke, Morgan A.; Hundley, Jacob M.; Masur, Lawrence J.

    2017-08-01

    Substitution of conventional honeycomb composite sandwich structures with lighter alternatives has the potential to reduce the mass of future vehicles. Here we demonstrate nanocrystalline aluminum-manganese truss cores that achieve 2-4 times higher strength than aluminum alloy 5056 honeycombs of the same density. The scalable fabrication approach starts with additive manufacturing of polymer templates, followed by electrodeposition of nanocrystalline Al-Mn alloy, removal of the polymer, and facesheet integration. This facilitates curved and net-shaped sandwich structures, as well as co-curing of the facesheets, which eliminates the need for extra adhesive. The nanocrystalline Al-Mn alloy thin-film material exhibits high strength and ductility and can be converted into a three-dimensional hollow truss structure with this approach. Ultra-lightweight sandwich structures are of interest for a range of applications in aerospace, such as fairings, wings, and flaps, as well as for the automotive and sports industries.

  20. ANALISIS KERAGAAN PANEL SANDWICH UNTUK RUMAH PRA-PABRIKASI

    Directory of Open Access Journals (Sweden)

    Naresworo Nugroho

    2010-12-01

    Full Text Available In the last five years, several earthquakes struck several places in Indonesia and thousands of people died caused of their masonry house. Therefore, the idea of bamboo utilization in the form of structural sandwich panel components for anti-seismic pre-fabrication house is one of appropriate way out. This research describes the performance and behavior of engineered structure wooden-bamboo sandwich panel in full sized test. The wall frame being use were meranti wood, this frame attached by plywood as face and back, then 5 cm bamboo cutting as core; the fastener used in this study were isocyanate resin and nails. This study carried out by experimental data of full scale structural tests on shear wall (ISO 22452. These result showed that the seismic reliability of the wall frame system made of bamboo sandwich panel was appropriate and will be useful for pre-fabrication houses as anti-seismic and environment friendly residential building

  1. Damage assessment of compression loaded debond damaged sandwich panels

    DEFF Research Database (Denmark)

    Moslemian, Ramin; Berggreen, Christian; Quispitupa, Amilcar

    2010-01-01

    with an implanted circular face/core debond. Compression tests were conducted on intact sandwich panels and panels with an implanted circular face/core debond with three different types of foam core materials (PVC H130, PVC H250 and PMI 51-IG). The strains and out-of-plane displacements of the debonded region were...... be minimized. Some of these applications involve the use of highly optimized sandwich solutions. Studies are under way to establish how the structural performance is influenced by the presence of production defects or in-service damage. This paper deals with the failure of compression loaded sandwich panels...... monitored using digital image correlation (DIC) measurements. Mixed mode bending (MMB) fracture characterization tests were conducted to determine the fracture toughness of the face/core interface in the panels. Finite element analysis and linear elastic fracture mechanics were employed to determine...

  2. Evaluation of an inhouse rapid ELISA test for detection of giardia in domestic sheep (Ovis aries).

    Science.gov (United States)

    Wilson, Jolaine M; Hankenson, F Claire

    2010-11-01

    Sheep (Ovis aries) are increasingly used at our institution as models of human disease. Within the research environment, routine husbandry and handling of sheep has potential for transmission of zoonotic agents, including Giardia. The prevalence of Giardia in sheep may approach 68%. Classic diagnostic testing involves microscopic examination for fecal cysts or trophozoites; however, limitations of microscopy include time, labor, and potential false-negative results due to intermittent shedding. We wished to determine whether a commercial rapid ELISA used for Giardia detection in dogs and cats could be used in sheep. Fecal samples collected from sheep (n = 93) were tested with a combination of 6 methods: reference laboratory fecal flotation, reference laboratory ELISA, inhouse fecal flotation, and commercially available tests (enzyme immunoassay, direct fluorescence antibody assay, and rapid ELISA). Prevalence of Giardia infection in facility sheep was 11.8% (11 of 93 animals). Of the 11 samples considered positive, 3 were confirmed by multiple testing methods, and 5 were positive by microscopy alone. Inhouse fecal flotation for 8 samples was positive on only 1 of 2 consecutive testing days. The rapid ELISA test exhibited 0% sensitivity for sheep giardiasis. Overall, the examined methods had low sensitivities and low positive predictive values. Despite limitations, microscopic analysis of repeat fecal samples remained the most accurate diagnostic method for ovine giardiasis among the methods tested.

  3. A micro ELISA for the diagnosis of cerebral cisticercosis.

    Science.gov (United States)

    Nunez, R; Munoz, A; Nunez, C; Gomez, B

    1989-01-01

    A micro ELISA for cysticercosis in the central nervous system was evaluated in 24 patients and compared with indirect hemagglutination. CSF ELISA results were positive in 17 of 20 patients (sensitivity 85%), whereas CSF indirect hemagglutination was positive in only 14 patients (sensitivity 70%).

  4. Calculation of dynamic stresses in viscoelastic sandwich beams using oma

    DEFF Research Database (Denmark)

    Pelayo, F.; Aenlle, M. L.; Ismael, G.

    2017-01-01

    The mechanical response of sandwich elements with viscoelastic core is time and temperature dependent. Laminated glass is a sandwich element where the mechanical behavior of the glass layers is usually considered linear-elastic material whereas the core is made of an amorphous thermoplastic which...... data. In simple structures, analytical mode shapes can be used alternatively to the numerical ones. In this paper, the dynamic stresses on the glass layers of a laminated glass beam have estimated using the experimental acceleration responses measured at 7 points of the beam, and the experimental mode...

  5. Friction stir welding (FSW of aluminium foam sandwich panels

    Directory of Open Access Journals (Sweden)

    M. Bušić

    2016-07-01

    Full Text Available The article focuses on the influence of welding speed and tool tilt angle upon the mechanical properties at the friction stir welding of aluminium foam sandwich panels. Double side welding was used for producing butt welds of aluminium sandwich panels applying insertion of extruded aluminium profile. Such insertion provided lower pressure of the tool upon the aluminium panels, providing also sufficient volume of the material required for the weldment formation. Ultimate tensile strength and flexural strength for three-point bending test have been determined for samples taken from the welded joints. Results have confirmed anticipated effects of independent variables.

  6. Blocking ELISA using recombinant NcSRS2 protein for diagnosing bovine neosporosis.

    Science.gov (United States)

    Sinnott, Francine A; Monte, Leonardo G; Collares, Thais F; De Matos, Bruno M; Pacheco, Diene B; Borsuk, Sibele; Andreotti, Renato; Hartleben, Cláudia P

    2015-03-01

    Neospora caninum is the etiologic agent of neosporosis, which leads to economic impacts on cattle industry. The reference method for serodiagnosis of neosporosis is the indirect fluorescent antibody test (IFAT). However, IFAT is laborious, expensive, and is not practicable in high throughput screening. In order to facilitate the serological diagnosis of neosporosis, we developed a blocking enzyme-linked immunosorbent assay (b-ELISA) based on NcSRS2 recombinant protein (rNcSRS2) and polyclonal antibodies against rNcSRS2 (b-ELISA/rNcSRS2). Compared to IFAT, b-ELISA/rNcSRS2 showed 93.7 % accuracy (98.7 % sensitivity and 88.7 % specificity), suggesting its potential as diagnostic assay to detect N. caninum antibodies in cattle sera.

  7. IgG Adhesion on Hydrophobic Surfaces: Theory, Modelling, and Application to ELISA

    CERN Document Server

    de Thier, P

    2016-01-01

    Enzyme-Linked ImmunoSorbent Assays (ELISA) are a range of widely used analytical methods whose implementation requires to build antibodies (IgG) thin films onto surfaces predominantly made of polystyrene. The high hydrophobicity of polystyrene ensures a spontaneous and strong adhesion of proteins allowing to easily build IgG monolayers. Since the ELISA improvements definitely lie in the comprehension of physico-chemical mechanisms on which IgG immobilization on hydrophobic surfaces are relied, this work develops a theorization essay (thermodynamics of the so-called hydrophobic effect and of thin films building) emphasized by numerical modelling (random sequential additions model, i.e. RSA) and experimental estimations by atomic force microscopy (AFM) and ELISA. Keeping in mind the hydrophobic effect, thermodynamics (of irreversible processes) allows to explain why IgG adhesion on polystyrene occurs whereas numerical modelling approaches show a way of surface saturation leading to promote IgG orientations expe...

  8. Evaluation of commercial ELISA kits for detection of antibodies against bovine atypical pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Uttenthal, Åse

    and less laborious option allowing screening for antibodies in large populations. Since test specific for emerging and new BVDV strains are still under preparation, the purpose of this work was to evaluate available BVDV antibody ELISA assays for their ability to detect antibodies against Hobi-like viruses....... Analysis of a panel of sera obtained from calves experimentally inoculated with Hobi-like virus (isolated from a calf from Thailand) and BVDV type 1 strain using five different ELISA kits in comparison to neutralization test was performed. The specificity and sensitivity of the tests depended greatly......A group of emerging bovine pestiviruses becomes a possible threat to Bovine Viral diarrhea virus (BVDV) control and eradication programs in the countries of their origin and in the new continents due to the lack of validated detection methods. The use of ELISA kits may be acheaper, time saving...

  9. Use of compact sandwich specimen to determine the critical strain energy release rate of bone.

    Science.gov (United States)

    Paruchuru, S P; Wang, X; Agrawal, C M

    2007-01-01

    The current methods to measure bone fracture toughness were initially developed for engineering materials and use specimen configurations that demand large samples. However, in many cases it is hard if not impossible to obtain such specimens from limited bone stock. Therefore, a new compact sandwich (CS) test method was formulated to measure the critical strain energy release rate (a measure of fracture toughness) of bone requiring only small samples. This technique may be used to assess bone fracture toughness and subsequently the bone quality.

  10. Vibroacoustic flexural properties of symmetric honeycomb sandwich panels with composite faces

    Science.gov (United States)

    Guillaumie, Laurent

    2015-05-01

    The vibroacoustic bending properties of honeycomb sandwich panels with composite faces are studied from the wavenumber modulus to the mechanical impedance, passing through the modal density. Numerical results extracted from finite element software computations are compared with analytical results. In both cases, the homogenization method is used to calculate the global properties of the sandwich panel. Since faces are made of composite material, the classical laminate theory serves as reference. With particular conditions used in the application for symmetric panels, the original orthotropic mechanical properties can be reduced simply to three parameters commonly used in vibroacoustic characterizations. These three parameters are the mass per unit area, the bending rigidity and the out-of-plane shear rigidity. They simultaneously govern the wavenumber modulus, the modal frequencies, the modal density and the mechanical impedance. For all of these vibroacoustic characterizations, a special frequency called the transition frequency separates two domains. In the first domain, below the transition frequency or for low frequencies, the orthotropic sandwich panel has a classical isotropic plate behavior. In the second domain, above the transition frequency or for high frequencies, the out-of-plane shear rigidity is very significant and changes the behavior. However, the results discussed are only valid up to a certain frequency which is determined by the thickness and out-of-plane shear stiffness of the honeycomb core, the thickness and the bending stiffness of the laminated face sheets and then the mass per unit area and bending stiffness of the total sandwich structure. All these parameters influence the final choice of model and simplifications presented. Experimental measurements of the bending wavenumber modulus and modal frequencies for our own application were carried out. In the vibroacoustic domain, the critical frequency is also an important frequency. It again

  11. Effect of proteolysis during Cheddar cheese aging on the detection of milk protein residues by ELISA.

    Science.gov (United States)

    Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L

    2017-03-01

    Cow milk is a common allergenic food, and cow milk-derived cheese retains an appreciable level of allergenicity. The specific and sensitive detection of milk protein residues in foods is needed to protect milk-allergic consumers from exposure to undeclared milk protein residues contained in foods made with milk or milk-derived ingredients or made on shared equipment or in shared facilities with milk or milk-derived ingredients. However, during cheese ripening, milk proteins are degraded by chymosin and milk-derived and bacterial proteases. Commercial allergen-detection methods are not validated for the detection of residues in fermented or hydrolyzed products. The objective of this research was to evaluate commercially available milk ELISA kits for their capability to detect milk protein residues in aged Cheddar cheese. Cheddar cheese was manufactured at a local dairy plant and was aged at 5°C for 24 mo, with samples removed at various time points throughout aging. Milk protein residues and protein profiles were measured using 4 commercial milk ELISA kits and sodium dodecyl sulfate-PAGE. The ELISA data revealed a 90% loss of milk protein residue signal between the youngest and oldest Cheddar cheese samples (0.5 and 24 mo, respectively). Sodium dodecyl sulfate-PAGE analysis showed protein degradation throughout aging, with the highest level of proteolysis observed at 24 mo. Results suggest that current commercial milk ELISA methods can detect milk protein residues in young Cheddar cheese, but the detection signal dramatically decreases during aging. The 4 evaluated ELISA kits were not capable of detecting trace levels of milk protein residues in aged cheese. Reliable detection of allergen residues in fermented food products is critical for upholding allergen-control programs, maintaining product safety, and protecting allergic consumers. Furthermore, this research suggests a novel use of ELISA kits to monitor protein degradation as an indication of cheese ripening

  12. Multi-objective optimization of a functionally graded sandwich panel under mechanical loading in the presence of stress constraint

    Science.gov (United States)

    Ashjari, Mohammad; Khoshravan, Mohammad Reza

    2017-12-01

    A method was presented for multi-objective optimization of material distribution of simply supported functionally graded (FG) sandwich panel, and sensitivity analyses of optimal designs were also conducted based on design variables and objective functions. The material composition was assumed to vary only in the thickness direction. Piecewise cubic interpolation of volume fractions was used to calculate volume fractions of constituent material phases at a point; these fractions were defined at a limited number of evenly spaced control points. The effective material properties of the panel were obtained by applying the linear rule of mixtures. The behavior of FG sandwich panel was predicted by Reddy's assumptions of third-order shear deformation theory. Exact solutions for deflections and stresses of simply supported sandwich panel were presented using the Navier-type solution technique. The volume fractions at control points, material, and thickness of the faces which were selected as decision variables were optimized by a multi-objective evolutionary algorithm known as the fast and elitist multi-objective genetic algorithm (NSGA-II). The mass and deflection of the model were considered the objective functions to be minimized with stress constraints. This model was optimized to verify the capability and efficiency of the proposed model under mechanical loading. The framework proposed for designing FG sandwich panel under pure mechanical conditions was furnished by the results.

  13. Measuring BDNF in saliva using commercial ELISA : Results from a small pilot study

    NARCIS (Netherlands)

    Vrijen, Charlotte; Schenk, Hendrika M.; Hartman, Catharina A.; Oldehinkel, Albertine J.

    Brain-derived neurotrophic factor (BDNF) is a protein often studied in psychiatric populations. Commercial ELISA kits have been validated for measuring BDNF in blood plasma and serum, but blood collection is an invasive method which cannot always be used. The aim of this pilot study was to explore

  14. Experimental Study on the Performance of Polyurethane-Steel Sandwich Structure under Debris Flow

    National Research Council Canada - National Science Library

    Peizhen Li; Shutong Liu; Zheng Lu

    2017-01-01

    Polyurethane-steel sandwich structure, which creatively uses the polyurethane-steel sandwich composite as a structural material, is proposed to strengthen the impact resistance of buildings under debris flow...

  15. Application of fibre reinforced plastic sandwich structures for automotive crashworthiness applications

    NARCIS (Netherlands)

    Lukaszewicz, D.; Blok, L.G.; Kratz, J.; Ward, C.; Kassapoglou, C.; Elmarakbi, A.; Araújo, A.L.

    2016-01-01

    In this work the application of fibre reinforced plastic (FRP) sandwich
    structures, with particular focus on aramid fibre tufted sandwiches is being studied for
    automotive crashworthiness applications using impact testing and numerical simulation.

  16. Mechanical testing of CFRP materials for application as skins of sandwich composites

    National Research Council Canada - National Science Library

    Adriana Stefan; Cristina-Elisabeta Pelin; George Pelin; Oleg Smorygo; Vitali Mikutski

    2017-01-01

    .... For the evaluation of sandwich composites based on metallic foam core, a larger study is being currently conducted, one of the objectives within this study being the evaluation of the sandwich system components...

  17. Simulation of Prestressed Concrete Sandwich Panels Subjected to Blast Loads (Preprint)

    Science.gov (United States)

    2010-02-01

    AFRL-RX-TY-TP-2010-0014 PREPRINT SIMULATION OF PRESTRESSED CONCRETE SANDWICH PANELS SUBJECTED TO BLAST LOADS Charles M. Newberry and...NUMBER (Include area code) 01-FEB-2010 Conference Paper PREPRINT 01-JAN-2009-- 31-DEC-2009 Simulation of Prestressed Concrete Sandwich Panels Subjected... concrete , sandwich panels, simulation, LS-DYNA, blast, tilt-up panels U U U UU 14 Paul Sheppard Reset Simulation of Prestressed Concrete Sandwich

  18. The Rightful Demise of the Sh*t Sandwich: Providing Effective Feedback.

    Science.gov (United States)

    James, Ian Andrew

    2015-11-01

    As a trainee cognitive therapist in the early 1990s, I was taught the Sh*t Sandwich by my supervisor. I continued to use this technique for many years without seeing the need to extend my repertoire of feedback strategies. This article describes a number of other feedback techniques, raising awareness of the processes underpinning feedback, and facilitating reflection on feedback methods. This review examines feedback and the methods of feedback used to improve clinical competence. Evidence informs us that the use of good feedback has a significant effect on learners' outcomes (Milne, 2009). However, despite recognition of its importance, many supervisors fail to give adequate feedback and utilize methods that are sub-optimal. One such problematic method is the notorious "Sh*t Sandwich" (SS), which attempts to hide criticism within a cushion of two positive statements. This paper looks at various models of giving negative and positive feedback, suggesting that our repertoire of feedback methods may require expanding. The review suggests that feedback is a complex process and methods that place an emphasis on the learner as an active participant in the learning process (i.e. interactive approaches) should be encouraged. The paper suggests that negative feedback should generally be avoided in favour of constructive support, accompanied by specific, descriptive, balanced feedback, with new learning being consolidated by role play. Generally, feedback should be given about the task rather than the person, but when it is personalized it should relate to effort rather than ability.

  19. A sandwich-type electrochemical immunosensor based on in situ silver deposition for determination of serum level of HER2 in breast cancer patients.

    Science.gov (United States)

    Shamsipur, Mojtaba; Emami, Mahdi; Farzin, Leila; Saber, Reza

    2018-04-30

    The sensitive quantification of Human Epidermal growth factor Receptor 2 (HER2), as a key prognostic tumor marker, plays a critical role in screening, early diagnosis and management of breast cancer. This paper describes a sandwich-type immunoassay with silver signal enhancement strategy for highly sensitive detection of HER2. For this purpose, the target capturing step was designed by functionalization of 3-aminopropyltrimethoxysilane coated magnetite nanoparticles with antibody (antiHER2/APTMS-Fe3O4), as a platform bioconjugate (PB), and immobilized at a bare GCE. Then, in the presence of label-free immunosensor, the PB was covered by magnetic gold nanoparticles self-assembled with thiolated antibodies (antiHER2/Hyd@AuNPs-APTMS-Fe3O4) containing chemically reduced silver ions, as a label bioconjugate (LB). Under optimum conditions, a linear relationship between the differential pulse voltammetric (DPV) stripping signal of silver and the logarithm of HER2 concentrations was obtained in the range of 5.0 × 10-4-50.0ngmL-1 (R2 = 0.9906) with a detection limit of 2.0 × 10-5ngmL-1. The effectiveness of this protocol was evaluated experimentally through employing of designed immunosensor for detection of the serum level of tumor marker. The good consistency of the results with those obtained by the enzyme-linked immunosorbent assay (ELISA) conventional method (p-value of immunosensor can be applied for the testing of HER2 in clinical samples of breast cancer patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Applicability of ELISA-based Determination of Pesticides for Groundwater Quality Monitoring

    Science.gov (United States)

    Tsuchihara, Takeo; Yoshimoto, Shuhei; Ishida, Satoshi; Imaizumi, Masayuki

    The principals and procedures of ELISA (Enzyme-linked Immunosorbent Assay)-based determination of pesticides (Fenitrothion) in environmental samples were reviewed, and the applicability of the ELISA method for groundwater quality monitoring were validated through the experimental tracer tests in soil columns and the field test in Okinoerabu Island. The test results showed that the ELISA method could be useful not only for screening but also for quantitative analysis of pesticides. In the experimental tracer tests in soil columns, the retardation of pesticides leaching compared with conservative tracers were observed. In the field test, the contamination of the pesticide was detected in groundwater samples in Okinoerabu Island, even though the targeted pesticide was considered to be applied to the upland field 4 months ago. In order to investigate the transport and fate of pesticides in groundwater taking into account retardation from the field to groundwater table and the residue in groundwater, continuous observations of pesticides in groundwater are in a strong need, and the ELISA method is applicable to the long-term quality groundwater monitoring.

  1. Stabilization of nonlinear sandwich systems via state feedback-Discrete-time systems

    NARCIS (Netherlands)

    Wang, Xu; Stoorvogel, Antonie Arij; Saberi, Ali; Grip, H°avard Fjær; Sannuti, Peddapullaiah

    A recent paper (IEEE Trans. Aut. Contr. 2010; 55(9):2156–2160) considered stabilization of a class of continuous-time nonlinear sandwich systems via state feedback. This paper is a discrete-time counterpart of it. The class of nonlinear sandwich systems consists of saturation elements sandwiched

  2. On the use of a woven mat to control the crack path in composite sandwich structures

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    In the last couple of decades the use of sandwich structures has increased tremendously in applications where low weight is of importance e.g. ship structures, where sandwich panels are often built from fiber reinforced faces and foam cores. An important damage type in sandwich structures is sepa...

  3. The Influence of Face Sheet Wrinkle Defects on the Performance of FRP Sandwich Structures

    DEFF Research Database (Denmark)

    Hayman, Brian; Berggreen, Carl Christian; Pettersson, Robert

    2005-01-01

    reported here, the influence of wrinkle defects on the in-plane compressive strength of quasiisotropic CFRP laminates used in PVC foam-cored sandwich panels has been investigated by three approaches: testing of sandwich beam specimens in fourpoint bending, testing of sandwich panels with in...

  4. Flexural Strength of Functionally Graded Nanotube Reinforced Sandwich Spherical Panel

    Science.gov (United States)

    Mahapatra, Trupti R.; Mehar, Kulmani; Panda, Subrata K.; Dewangan, S.; Dash, Sushmita

    2017-02-01

    The flexural behaviour of the functionally graded sandwich spherical panel under uniform thermal environment has been investigated in the present work. The face sheets of the sandwich structure are made by the functionally graded carbon nanotube reinforced material and the core face is made by the isotropic and homogeneous material. The material properties of both the fiber and matrix are assumed to be temperature dependent. The sandwich panel model is developed in the framework of the first order shear deformation theory and the governing equation of motion is derived using the variational principle. For the discretization purpose a suitable shell element has been employed from the ANSYS library and the responses are computed using a parametric design language (APDL) coding. The performance and accuracy of the developed model has been established through the convergence and validation by comparing the obtained results with previously published results. Finally, the influence of different geometrical parameters and material properties on the flexural behaviour of the sandwich spherical panel in thermal environment has been investigated through various numerical illustrations and discussed in details.

  5. Sandwiched Between Strasbourg and Karlsruhe: EU Fundamental Rights Protection

    NARCIS (Netherlands)

    Reestman, J.H.; Besselink, L.

    2016-01-01

    Starting out from the notion of the `Verfassungsgerichtsverbund´, coined by the President Vosskuhle of the German Federal Constitutional Court, this contribution sketches the manner in which the European Court of Justice operates, sandwiched in between the European Court of Human Rights that sets a

  6. Electrowetting-driven oscillating drops sandwiched between two substrates

    NARCIS (Netherlands)

    Mampallil Augustine, Dileep; Eral, Burak; Staicu, A.D.; Mugele, Friedrich Gunther; van den Ende, Henricus T.M.

    2013-01-01

    Drops sandwiched between two substrates are often found in lab-on-chip devices based on digital microfluidics. We excite azimuthal oscillations of such drops by periodically modulating the contact line via ac electrowetting. By tuning the frequency of the applied voltage, several shape modes can be

  7. Application of Load Carrying Sandwich Elements in Wind Turbine Blades

    DEFF Research Database (Denmark)

    Jensen, Jacob Fisker; Schultz, Jacob Pagh; Berggreen, Carl Christian

    2005-01-01

    . For a single skin design, buckling is critical compared to other design criterions. By introducing sandwich, a significant weight reduction and increased buckling capacity is obtained. Tower clearance now becomes critical. Proper choice of core material and thickness is important to prevent face wrinkling...

  8. An Assessment of the Speed Reading Ability of Sandwich Students ...

    African Journals Online (AJOL)

    The paper discusses the concept and usefulness of rapid reading. It also reports a study in which the Faculty of Education, University of Lagos, Nigeria Sandwich students formed the subjects. Their pre-training reading speed and comprehension scores were determined through a pre-test, after which they were subjected to ...

  9. Investigation on Wall Panel Sandwiched With Lightweight Concrete

    Science.gov (United States)

    Lakshmikandhan, K. N.; Harshavardhan, B. S.; Prabakar, J.; Saibabu, S.

    2017-08-01

    The rapid population growth and urbanization have made a massive demand for the shelter and construction materials. Masonry walls are the major component in the housing sector and it has brittle characteristics and exhibit poor performance against the uncertain loads. Further, the structure requires heavier sections for carrying the dead weight of masonry walls. The present investigations are carried out to develop a simple, lightweight and cost effective technology for replacing the existing wall systems. The lightweight concrete is developed for the construction of sandwich wall panel. The EPS (Expanded Polystyrene) beads of 3 mm diameter size are mixed with concrete and developed a lightweight concrete with a density 9 kN/m3. The lightweight sandwich panel is cast with a lightweight concrete inner core and ferrocement outer skins. This lightweight wall panel is tested for in-plane compression loading. A nonlinear finite element analysis with damaged plasticity model is carried out with both material and geometrical nonlinearities. The experimental and analytical results were compared. The finite element study predicted the ultimate load carrying capacity of the sandwich panel with reasonable accuracy. The present study showed that the lightweight concrete is well suitable for the lightweight sandwich wall panels.

  10. Factors that Influence Information Seeking Behaviour of Sandwich ...

    African Journals Online (AJOL)

    This study examined the factors that influence the information seeking behavior of sandwich students in selected Nigerian Univ ersities. Questionnaire was used to collect data with a response rate of (97.30%). Among the factors that influence information seeking is availability of internet resources in or near the library; ...

  11. Factors that Influence Information Seeking Behaviour of Sandwich ...

    African Journals Online (AJOL)

    This study examined the factors that influence the information seeking behavior of sandwich students in selected Nigerian Universities. Questionnaire was used to collect data with a response rate of (97.30%). Among the factors that influence information seeking is availability of internet resources in or near the library; ...

  12. A Debonded Sandwich Specimen Under Mixed Mode Bending (MMB)

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    for the MMB specimen were derived from a superposition analysis. An experimental verification of the methodology proposed was performed using MMB sandwich specimens with H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 faces. Different mixed mode loadings were applied...

  13. Two-dimensional analysis of shallow sandwich panels

    DEFF Research Database (Denmark)

    Skvortsov, V; Bozhevolnaya, Elena

    2001-01-01

    The shallow singly curved and rectangular in-plane sandwich panels affected by lateral loads are considered. The set of governing equations on the basis of the Timoshenko-Reissner plate theory is derived for these panels in the case of general boundary conditions. Usage of any real boundary...

  14. Multiscale Finite-Element Modeling of Sandwich Honeycomb Composite Structures

    Directory of Open Access Journals (Sweden)

    Yu. I. Dimitrienko

    2014-01-01

    Full Text Available The paper presents a developed multi-scale model of sandwich honeycomb structures. The model allows us both to calculate effective elastic-strength characteristics of honeycomb and forced covering of sandwich, and to find a 3D stress-strain state of structures using the threedimensional elastic theory for non- homogeneous media. On the basis of finite element analysis it is shown, that under four-point bending the maximal value of bending and shear stresses in the sandwich honeycomb structures are realized in the zone of applied force and plate support. Here the local stress maxima approximately 2-3 times exceed the “engineering” theoretical plate values of bending and shear stresses in the middle of panel. It is established that at tests for fourpoint bending there is a failure of the honeycomb sandwich panels because of the local adhesion failure rather than because of the covering exfoliation off the honeycomb core in the middle of panel.

  15. Shear properties evaluation of a truss core of sandwich beams

    Science.gov (United States)

    Wesolowski, M.; Ludewicz, J.; Domski, J.; Zakrzewski, M.

    2017-10-01

    The open-cell cores of sandwich structures are locally bonded to the face layers by means of adhesive resin. The sandwich structures composed of different parent materials such as carbon fibre composites (laminated face layers) and metallic core (aluminium truss core) brings the need to closely analyse their adhesive connections which strength is dominated by the shear stress. The presented work considers sandwich beams subjected to the static tests in the 3-point bending with the purpose of estimation of shear properties of the truss core. The main concern is dedicated to the out-of plane shear modulus and ultimate shear stress of the aluminium truss core. The loading of the beam is provided by a static machine. For the all beams the force - deflection history is extracted by means of non-contact optical deflection measurement using PONTOS system. The mode of failure is identified for each beam with the corresponding applied force. A flexural rigidity of the sandwich beams is also discussed based on force - displacement plots.

  16. Pulsed terahertz inspection of non-conducting sandwich composites

    Science.gov (United States)

    Lopato, P.; Chady, T.

    2013-01-01

    Pulsed terahertz inspection enables accurate, contactless and safe for operating personnel evaluation of non-conducting structures. In this paper we present results of pulsed terahertz testing of various sandwich composite structures incorporating glass and basalt fibers based skin materials and spherecore and balsa wood based core materials. Various Time-Frequency Distributions (TFD) are utilized in order to obtain most valuable defects response.

  17. Compressive Behaviour and Energy Absorption of Aluminium Foam Sandwich

    Science.gov (United States)

    Endut, N. A.; Hazza, M. H. F. Al; Sidek, A. A.; Adesta, E. T. Y.; Ibrahim, N. A.

    2018-01-01

    Development of materials in automotive industries plays an important role in order to retain the safety, performance and cost. Metal foams are one of the idea to evolve new material in automotive industries since it can absorb energy when it deformed and good for crash management. Recently, new technology had been introduced to replace metallic foam by using aluminium foam sandwich (AFS) due to lightweight and high energy absorption behaviour. Therefore, this paper provides reliable data that can be used to analyze the energy absorption behaviour of aluminium foam sandwich by conducting experimental work which is compression test. Six experiments of the compression test were carried out to analyze the stress-strain relationship in terms of energy absorption behavior. The effects of input variables include varying the thickness of aluminium foam core and aluminium sheets on energy absorption behavior were evaluated comprehensively. Stress-strain relationship curves was used for energy absorption of aluminium foam sandwich calculation. The result highlights that the energy absorption of aluminium foam sandwich increases from 12.74 J to 64.42 J respectively with increasing the foam and skin thickness.

  18. Examination of Sandwich Materials Using Air-Coupled Ultrasonics

    DEFF Research Database (Denmark)

    Borum, K.K.; Berggreen, Carl Christian

    2004-01-01

    The air-coupled ultrasonic techniques have been improved drastically in recent years. Better equipment has made this technique much more useful. This paper focuses on the examination of sandwich materials used in naval ships. It is more convenient to be able to make the measurements directly...

  19. Outcome of the TURP-TUVP sandwich procedure for minimally ...

    African Journals Online (AJOL)

    Bladder neck stenosis occurred in 3 patients and was successfully treated with bladder neck incision. Conclusions: The sandwich combination of TURP and TUVP for the surgical treatment of BPH with volume larger than 40cc had satisfactory patient safety profile and resulted in significant improvement in IPSS, Qmax and ...

  20. Enhanced detection levels in a semi-automated sandwich ...

    African Journals Online (AJOL)

    A peptide nucleic acid (PNA) signal probe was tested as a replacement for a typical DNA oligonucleotidebased signal probe in a semi-automated sandwich hybridisation assay designed to detect the harmful phytoplankton species Alexandrium tamarense. The PNA probe yielded consistently higher fluorescent signal ...

  1. Residual Strength of In-plane Loaded Debonded Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian; Simonsen, Bo Cerup

    2005-01-01

    This paper presents a FEM based numerical model for prediction of residual strength of damaged sandwich panels. As demonstrated, the model can predict the maximum load carrying capacity of real-life panels with debond damages, where the failure is governed by face-sheet buckling followed by debond...

  2. Design and Testing of Sandwich Structures with Different Core Materials

    Directory of Open Access Journals (Sweden)

    Henrik HERRANEN

    2012-03-01

    Full Text Available The purpose of this study was to design a light-weight sandwich panel for trailers. Strength calculations and selection of different materials were carried out in order to find a new solution for this specific application. The sandwich materials were fabricated using vacuum infusion technology. The different types of sandwich composite panels were tested in 4-point bending conditions according to ASTM C393/C393M. Virtual testing was performed by use of ANSYS software to simplify the core material selection process and to design the layers. 2D Finite element analysis (FEA of 4-point bending was made with ANSYS APDL (Classic software. Data for the FEA was obtained from the tensile tests of glass fiber plastic (GFRP laminates. Virtual 2D results were compared with real 4-point bending tests.  3D FEA was applied to virtually test the selected sandwich structure in real working conditions. Based on FEA results the Pareto optimality concept has been applied and optimal solutions determined.DOI: http://dx.doi.org/10.5755/j01.ms.18.1.1340

  3. Residual Strength of In-plane Loaded Debonded Sandwich Panels

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Nøkkentved, Alexandros; Berggreen, Carl Christian

    2005-01-01

    Face/core debond damaged sandwich panels exposed to uniform and non-uniform compression loads are studied experimentally. The panel geometry is full-scale rectangular with a centrally located circular prefabricated debond. The results show a considerable strength reduction with increasing debond...

  4. Development of biobased sandwich structures for mass transit application

    Science.gov (United States)

    Munusamy, Sethu Raaj

    Efforts to increase the biobased content in sandwich composites are being investigated to reduce the dependence on synthetically produced or mined, energy-intensive materials for numerous composite applications. Vegetable oil-based polyurethane foams are gaining recognition as good substitutes for synthetic counter parts while utilizing bast fiber to replace fiberglass is also gaining credence. In this study, soy oil-based polyurethane foam was evaluated as a core in a sandwich construction with facesheets of hybridized kenaf and E-glass fibers in a vinyl ester resin matrix to replace traditionally used plywood sheeting on steel frame for mass transit bus flooring systems. As a first step towards implementation, the static performance of the biobased foam was compared to 100% synthetic foam. Secondly, biobased sandwich structures were processed and their static performance was compared to plywood. The biobased sandwich composites designed and processed were shown to hold promise towards replacing plywood for bus flooring applications by displaying an increase of 130% for flexural strength and 135% for flexural modulus plus better indentation values.

  5. Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures

    Science.gov (United States)

    Nurge, Mark; Youngquist, Robert; Starr, Stanley

    2011-01-01

    Graphite epoxy composite (GEC) materials are used in the construction of rocket fairings, nose cones, interstage adapters, and heat shields due to their high strength and light weight. However, they absorb moisture depending on the environmental conditions they are exposed to prior to launch. Too much moisture absorption can become a problem when temperature and pressure changes experienced during launch cause the water to vaporize. The rapid state change of the water can result in structural failure of the material. In addition, heat and moisture combine to weaken GEC structures. Diffusion models that predict the total accumulated moisture content based on the environmental conditions are one accepted method of determining if the material strength has been reduced to an unacceptable level. However, there currently doesn t exist any field measurement technique to estimate the actual moisture content of a composite structure. A multi-layer diffusion model was constructed with Mathematica to predict moisture absorption and desorption from the GEC sandwich structure. This model is used in conjunction with relative humidity/temperature sensors both on the inside and outside of the material to determine the moisture levels in the structure. Because the core materials have much higher diffusivity than the face sheets, a single relative humidity measurement will accurately reflect the moisture levels in the core. When combined with an external relative humidity measurement, the model can be used to determine the moisture levels in the face sheets. Since diffusion is temperaturedependent, the temperature measurements are used to determine the diffusivity of the face sheets for the model computations.

  6. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  7. Ultrasonic guided wave characterization and damage detection in foam-core sandwich panel using PWAS and LDV

    Science.gov (United States)

    Chakraborty, Nibir; Roy Mahapatra, D.; Srinivasan, Gopalakrishnan

    2012-04-01

    Lamb wave type guided wave propagation in foam core sandwich structures and detectability of damages using spectral analysis method are reported in this paper. An experimental study supported by theoretical evaluation of the guided wave characteristics is presented here that shows the applicability of Lamb wave type guided ultrasonic wave for detection of damage in foam core sandwich structures. Sandwich beam specimens were fabricated with 10 mm thick foam core and 0.3 mm thick aluminum face sheets. Thin piezoelectric patch actuators and sensors are used to excite and sense guided wave. Group velocity dispersion curves and frequency response of sensed signal are obtained experimentally. The nature of damping present in the sandwich panel is monitored by measuring the sensor signal amplitude at various different distances measured from the center of the linear phased array. Delaminations of increasing width are created and detected experimentally by pitch-catch interrogation with guided waves and wavelet transform of the sensed signal. Signal amplitudes are analyzed for various different sizes of damages to differentiate the damage size/severity. A sandwich panel is also fabricated with a planer dimension of 600 mm x 400 mm. Release film delamination is introduced during fabrication. Non-contact Laser Doppler Vibrometer (LDV) is used to scan the panel while exciting with a surface bonded piezoelectric actuator. Presence of damage is confirmed by the reflected wave fringe pattern obtained from the LDV scan. With this approach it is possible to locate and monitor the damages by tracking the wave packets scattered from the damages.

  8. Effects of Structural Damage on Dynamic Behavior at Sandwich Composite Beams - Part I-Theoretical Approach

    Directory of Open Access Journals (Sweden)

    Tufoi Marius

    2014-07-01

    Full Text Available This paper series presents an analysis regarding the dynamics of sandwich composite beams, embedded at one end, in order to highlight the effect of geometrical and material discontinuities upon the natural frequencies. In first part (Part I, analysis was performed with EulerBernoulli analytical method for determining the vibration modes and in second part (Part II, analysis was performed with numerical simulation in SolidWorks software for a five-layer composite. In the last section of the paper, an example is shown regarding how to interpret the obtained results.

  9. On the Effect of Curvature in Debonded Sandwich Panels Subjected to Compressive Loading

    DEFF Research Database (Denmark)

    Moslemian, Ramin; Berggreen, Christian; Branner, Kim

    2008-01-01

    with a circular debond. The Crack Surface Displacement Extrapolation (CSDE) method is used to calculate fracture parameters in the interface. Compression tests were carried out on two types of debonded curved panels with different curvature using Digital Image Correlation (DIC) measurements to determine the full......The aim of this study is to obtain an understanding of the effect of panel curvature on residual compressive strength in debond damaged sandwich panels. Finite element analysis and linear elastic fracture mechanics are employed to analyze the residual compressive strength of curved panels...

  10. Prevalence of amoebiasis in a model research community and its confirmation using stool antigen elisa for Entamoeba histolytica.

    Science.gov (United States)

    Akhtar, Tasleem; Khan, Aamir Ghafoor; Ahmed, Israr; Nazli, Rubina; Haider, Jamila

    2016-09-01

    Entamoeba histolytica (E. histolytica) produces an invasive disease called amoebiasis, which commonly produces diarrhea with or without blood in both children and adults, leading to high morbidity and mortality. Entamoeba dispar (E. Dispar) is a non invasive, non pathogenic organism. Both Entamoeba histolytica and Entamoeba Dispar look alike on microscopy and therefore cannot be differentiated unless checked on ELISA, PCR or other specific method. To calculate the actual prevalence of pathogenic amoebiasis in children by comparing the stool microscopy with ELISA stool antigen i.e. gold standard. Across sectional, comparative study. Children under five years in a community village Budhni, District Peshawar. A sample of 288 children aged Entamoeba histolytica. The specificity and sensitivity of microscopic method was calculated against ELISA. Data was analyzed using statistical computer software package SPSS version 10.0. A total of 288 stool specimens were collected and examined for Entamoeba histolytica. Out of these 36(12.5%) stools were positive for E. histolyticaon microscopy while 14(4.9%) were positive on ELISA. Out of 14 ELISA positive samples, 10 samples were also positive on microscopy while 4 were ELISA positive but microscopy negative. About 22 samples, which were positive on microscopy were negative on ELISA indicating that these samples might have been of E. Dispar which is non pathogenic protozoa. The sensitivity and specificity of microscopic method was 71.4% and 90.5% respectively, as against stool antigen test. Actual prevalence of Entamoeba histolytica is low in the area. Stool ELISA was able to differentiate between pathogenic Entamoeba histolytica and the non-pathogenic Entamoeba dispar and thus can minimize unnecessary antiamoebic treatment in these children.

  11. Truncated MTA-1: A Pitfall in ELISA-Based Immunoassay of HTLV-1 Infection

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Abbaszadegan

    2008-01-01

    Full Text Available HTLV-1 causes adult T-cell leukemia (ATL and HTLV-1 associated myelopathy/tropical spastic paraparesis (HAM/TSP. Recombinant envelope glycoprotein is used in production of diagnostic enzyme-linked immunosorbent assay (ELISA kit. There are some reports that a significant percentage of Iranian HTLV-1 infected patients showed no seroreactivity with MTA-1 peptide, while HTLV-1 had been confirmed by PCR detection methods or ELISA kits containing a cocktail of HTLV-1 specific peptides. This report describes experiments designed to determine whether some discrepancies between ELISA and PCR results could be due to truncation of immunodominant epitopes using immunoassay method. We have cloned the MTA-1 epitope of env gene from HTLV-1 in NotI/NdeI sites of pET22b(+ expression vector. Sequencing analysis of recombinant plasmids revealed an insertion of a cytosine in position 271 causing a stop codon in the MTA-1 protein translation. SDS-PAGE analysis also failed to reveal the presence of the desired protein. Subjects with a mutant HTLV-1 env gene were shown to be seronegative using ELISA, but positive with PCR.

  12. Rapid Detection of Food Allergens by Microfluidics ELISA-Based Optical Sensor

    Directory of Open Access Journals (Sweden)

    Xuan Weng

    2016-06-01

    Full Text Available The risks associated with the presence of hidden allergens in food have increased the need for rapid, sensitive, and reliable methods for tracing food allergens in commodities. Conventional enzyme immunosorbent assay (ELISA has usually been performed in a centralized lab, requiring considerable time and sample/reagent consumption and expensive detection instruments. In this study, a microfluidic ELISA platform combined with a custom-designed optical sensor was developed for the quantitative analysis of the proteins wheat gluten and Ara h 1. The developed microfluidic ELISA biosensor reduced the total assay time from hours (up to 3.5 h to 15–20 min and decreased sample/reagent consumption to 5–10 μL, compared to a few hundred microliters in commercial ELISA kits, with superior sensitivity. The quantitative capability of the presented biosensor is a distinctive advantage over the commercially available rapid methods such as lateral flow devices (LFD and dipstick tests. The developed microfluidic biosensor demonstrates the potential for sensitive and less-expensive on-site determination for rapidly detecting food allergens in a complex sample system.

  13. ELISA: Structure-Function Inferences based on statistically significant and evolutionarily inspired observations

    Directory of Open Access Journals (Sweden)

    DeLisi Charles

    2003-09-01

    Full Text Available Abstract The problem of functional annotation based on homology modeling is primary to current bioinformatics research. Researchers have noted regularities in sequence, structure and even chromosome organization that allow valid functional cross-annotation. However, these methods provide a lot of false negatives due to limited specificity inherent in the system. We want to create an evolutionarily inspired organization of data that would approach the issue of structure-function correlation from a new, probabilistic perspective. Such organization has possible applications in phylogeny, modeling of functional evolution and structural determination. ELISA (Evolutionary Lineage Inferred from Structural Analysis, http://romi.bu.edu/elisa is an online database that combines functional annotation with structure and sequence homology modeling to place proteins into sequence-structure-function "neighborhoods". The atomic unit of the database is a set of sequences and structural templates that those sequences encode. A graph that is built from the structural comparison of these templates is called PDUG (protein domain universe graph. We introduce a method of functional inference through a probabilistic calculation done on an arbitrary set of PDUG nodes. Further, all PDUG structures are mapped onto all fully sequenced proteomes allowing an easy interface for evolutionary analysis and research into comparative proteomics. ELISA is the first database with applicability to evolutionary structural genomics explicitly in mind. Availability: The database is available at http://romi.bu.edu/elisa.

  14. Laser cutting sandwich structure glass-silicon-glass wafer with laser induced thermal-crack propagation

    Science.gov (United States)

    Cai, Yecheng; Wang, Maolu; Zhang, Hongzhi; Yang, Lijun; Fu, Xihong; Wang, Yang

    2017-08-01

    Silicon-glass devices are widely used in IC industry, MEMS and solar energy system because of their reliability and simplicity of the manufacturing process. With the trend toward the wafer level chip scale package (WLCSP) technology, the suitable dicing method of silicon-glass bonded structure wafer has become necessary. In this paper, a combined experimental and computational approach is undertaken to investigate the feasibility of cutting the sandwich structure glass-silicon-glass (SGS) wafer with laser induced thermal-crack propagation (LITP) method. A 1064 nm semiconductor laser cutting system with double laser beams which could simultaneously irradiate on the top and bottom of the sandwich structure wafer has been designed. A mathematical model for describing the physical process of the interaction between laser and SGS wafer, which consists of two surface heating sources and two volumetric heating sources, has been established. The temperature stress distribution are simulated by using finite element method (FEM) analysis software ABAQUS. The crack propagation process is analyzed by using the J-integral method. In the FEM model, a stationary planar crack is embedded in the wafer and the J-integral values around the crack front edge are determined using the FEM. A verification experiment under typical parameters is conducted and the crack propagation profile on the fracture surface is examined by the optical microscope and explained from the stress distribution and J-integral value.

  15. Elastic stability of superplastically formed/diffusion-bonded orthogonally corrugated core sandwich plates

    Science.gov (United States)

    Ko, W. L.

    1980-01-01

    The paper concerns the elastic buckling behavior of a newly developed superplastically formed/diffusion-bonded (SPF/DB) orthogonally corrugated core sandwich plate. Uniaxial buckling loads were calculated for this type of sandwich plate with simply supported edges by using orthotropic sandwich plate theory. The buckling behavior of this sandwich plate was then compared with that of an SPF/DB unidirectionally corrugated core sandwich plate under conditions of equal structural density. It was found that the buckling load for the former was considerably higher than that of the latter.

  16. The Planar Sandwich and Other 1D Planar Heat Flow Test Problems in ExactPack

    Energy Technology Data Exchange (ETDEWEB)

    Singleton, Jr., Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-24

    This report documents the implementation of several related 1D heat flow problems in the verification package ExactPack [1]. In particular, the planar sandwich class defined in Ref. [2], as well as the classes PlanarSandwichHot, PlanarSandwichHalf, and other generalizations of the planar sandwich problem, are defined and documented here. A rather general treatment of 1D heat flow is presented, whose main results have been implemented in the class Rod1D. All planar sandwich classes are derived from the parent class Rod1D.

  17. A novel SERRS sandwich-hybridization assay to detect specific DNA target.

    Directory of Open Access Journals (Sweden)

    Cécile Feuillie

    Full Text Available In this study, we have applied Surface Enhanced Resonance Raman Scattering (SERRS technology to the specific detection of DNA. We present an innovative SERRS sandwich-hybridization assay that allows specific DNA detection without any enzymatic amplification, such as is the case with Polymerase Chain Reaction (PCR. In some substrates, such as ancient or processed remains, enzymatic amplification fails due to DNA alteration (degradation, chemical modification or to the presence of inhibitors. Consequently, the development of a non-enzymatic method, allowing specific DNA detection, could avoid long, expensive and inconclusive amplification trials. Here, we report the proof of concept of a SERRS sandwich-hybridization assay that leads to the detection of a specific chamois DNA. This SERRS assay reveals its potential as a non-enzymatic alternative technology to DNA amplification methods (particularly the PCR method with several applications for species detection. As the amount and type of damage highly depend on the preservation conditions, the present SERRS assay would enlarge the range of samples suitable for DNA analysis and ultimately would provide exciting new opportunities for the investigation of ancient DNA in the fields of evolutionary biology and molecular ecology, and of altered DNA in food frauds detection and forensics.

  18. ELISA-PLA: A novel hybrid platform for the rapid, highly sensitive and specific quantification of proteins and post-translational modifications.

    Science.gov (United States)

    Tong, Qing-He; Tao, Tao; Xie, Li-Qi; Lu, Hao-Jie

    2016-06-15

    Detection of low-abundance proteins and their post-translational modifications (PTMs) remains a great challenge. A conventional enzyme-linked immunosorbent assay (ELISA) is not sensitive enough to detect low-abundance PTMs and suffers from nonspecific detection. Herein, a rapid, highly sensitive and specific platform integrating ELISA with a proximity ligation assay (PLA), termed ELISA-PLA, was developed. Using ELISA-PLA, the specificity was improved by the simultaneous and proximate recognition of targets through multiple probes, and the sensitivity was significantly improved by rolling circle amplification (RCA). For GFP, the limit of detection (LOD) was decreased by two orders of magnitude compared to that of ELISA. Using site-specific phospho-antibody and pan-specific phospho-antibody, ELISA-PLA was successfully applied to quantify the phosphorylation dynamics of ERK1/2 and the overall tyrosine phosphorylation level of ERK1/2, respectively. ELISA-PLA was also used to quantify the O-GlcNAcylation of AKT, c-Fos, CREB and STAT3, which is faster and more sensitive than the conventional immunoprecipitation and western blotting (IP-WB) method. As a result, the sample consumption of ELISA-PLA was reduced 40-fold compared to IP-WB. Therefore, ELISA-PLA could be a promising platform for the rapid, sensitive and specific detection of proteins and PTMs. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Influence of the inter-layer adhesion on the structural strength of sandwich pipes; Influencia da adesao entre camadas na resistencia estrutural de dutos sanduiche

    Energy Technology Data Exchange (ETDEWEB)

    Castello, Xavier; Estefen, Segen [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Oceanica

    2005-07-01

    Sandwich pipes composed of two steel layers separated by a polypropylene annulus can be used for the transport of oil and gas in deep waters, combining high structural resistance with thermal insulation in order to prevent blockage by paraffin and hydrates. In this work, sandwich pipes with typical inner diameters of those employed in the offshore production are analyzed numerically regarding to the influence of the inter-layer adhesion of steel pipes and polymer on the limit strength under external pressure and longitudinal bending as well as the bending and straightening process representative of the reeling installation method. The numerical model incorporates geometric and material non-linearity, which had been based on previous works of the authors. Tests of specimens under tension and segments of sandwich pipes are carried through to evaluate the maximum shear stresses of the interfaces metal-polymer. The adhesion is modeled by contact adopting a maximum shear stress value to allow the relative displacement between the layers. It was observed that the structural resistance of the sandwich pipe is strongly dependent on the shear stress acting at the interface, occurring the collapse of the pipe when the maximum shear stress is reached. The results obtained are analyzed to determine the minimum shear strength at the union which provides adequate structural resistance for the sandwich pipe under representative conditions of the installation and operation loading phases. (author)

  20. Enzyme-linked immunosorbent assay (ELISA) based on superparamagnetic nanoparticles for aflatoxin M1 detection.

    Science.gov (United States)

    Radoi, A; Targa, M; Prieto-Simon, B; Marty, J-L

    2008-10-19

    Five different clones of antibodies developed against the aflatoxin M(1) were investigated by using the classical indirect and direct competitive Enzyme-Linked Immunosorbent Assay (ELISA) formats, and also the direct competitive ELISA based on the use of the superparamagnetic nanoparticles. The purpose of this study was to assess if not so friendly time classical ELISA procedures can be further improved, by reducing the coating, blocking and competition time. Here we showed that a complete dc-ELISA (coating, blocking and competition step) based on the use of superparamagnetic nanoparticles can be performed in basically 40 min, if coating step (20 min) should be taken into account. Moreover, the standard analytical characteristics of the proposed method fulfil the requirements for detecting AFM(1) in milk, in a wide linear working range (4-250 ng/L). The IC(50) value is 15 ng/L. The matrix effect and the recovery rate were assessed, using the European Reference Material (BD282, zero level of AFM(1)), showing an excellent percentage of recovery, close to 100%.

  1. Sandwich allografts for long-bone nonunions in patients with osteogenesis imperfecta: a retrospective study.

    Science.gov (United States)

    Puvanesarajah, Varun; Shapiro, Jay R; Sponseller, Paul D

    2015-02-18

    Patients with osteogenesis imperfecta often develop nonunions, as internal fixation has limited applicability in this condition. We report the outcomes of a modified "sandwich technique" in the treatment of long-bone nonunions in patients with osteogenesis imperfecta; this technique brings circumferential stabilization and normal collagen to the nonunion site. From May 2003 through February 2012, twelve patients (eight females, four males; median age, 39.0 years; range, eleven to seventy-eight years) who had osteogenesis imperfecta (Sillence type I [three], type III [eight], and type IV [one]) and a combined total of thirteen nonunions (two humeral, two radial, three femoral, four tibial, and two ulnar; median duration, 15.0 months; range, six to 204 months) were treated at our institution with compressed sandwich allograft cortical struts. The struts were fashioned to be wide enough to allow for increased osteoconductive surface area and to approximate a hemicylindrical shape. Treatment history and demographics data were acquired through retrospective chart review. Follow-up radiographs were analyzed by two attending orthopaedic surgeons to determine radiographic findings. The median follow-up time was 4.6 years (range, 2.1 to 10.3 years). All thirteen nonunions, including one requiring a second graft procedure, healed with abundant, smooth allograft incorporation, resulting in an initial healing rate of 92% because of a refracture in one patient. This patient's nonunion ultimately healed with additional allograft struts and a new intramedullary rod. One patient required removal of prominent screws. The final follow-up examinations revealed no pain or refracture at the original nonunion site. All patients regained their prefracture level of function. Sandwich allograft struts constitute a durable, safe method for the stabilization and healing of persistent long-bone nonunions in patients with osteogenesis imperfecta. All patients showed incorporation of the

  2. Numerical and Experimental Low-Velocity Impact Behaivor of Sandwich Plates with Viscoelastic Core

    Directory of Open Access Journals (Sweden)

    Soroush Sadeghnejad

    2016-03-01

    Full Text Available A numerical and experimental low-velocity impact behavior of sandwich plates have been presently studied with regard to the compressibility and viscoelasticity features of their cores. Face sheets were assumed to be anisotropic composites or isotropic aluminum materials and a viscoelastic behavior has been considered for core. The boundary conditions are assumed to be simply supported or rigid. Abaqus, as FEM software, and its python script programming feature, have been used to model the specimens. To model hyper-viscoelastic nonlinear behavior of the core, Ogden hyper-foam elasticity and Prony series approach are manipulated. To solve the numerical problem, dynamic explicit solver option with sufficient solving amplitude has been used. Prony series have been used to model the core time-dependent behavior. In conjunction with a simple indentation experiment, FEM used to formulate a novel method for finding the Prony series coefficients. By performing some low-velocity impact experiments, the impact force and displacement of the composite sandwich plates have been investigated. The results indicate that increasing the structural damping increases the contact time and missing energy and decreases the stored energy of the system. The structures with composite face sheets have a minimum ratio of upper face sheet displacement to lower face sheet displacement in comparison to those with the isotropic face sheets. Impact behavior of isotropic face sheet specimens are more flattened than that of the composite face sheets. In addition, the specific energy stored in the sandwich plates with composite face sheets, on different supports, is greater than that stored in the aluminum face sheets.

  3. Diagnostic Accuracy of Antigen 5-Based ELISAs for Human Cystic Echinococcosis.

    Science.gov (United States)

    Pagnozzi, Daniela; Addis, Maria Filippa; Biosa, Grazia; Roggio, Anna Maria; Tedde, Vittorio; Mariconti, Mara; Tamarozzi, Francesca; Meroni, Valeria; Masu, Gabriella; Masala, Giovanna; Brunetti, Enrico; Uzzau, Sergio

    2016-03-01

    Clinical diagnosis and follow up of cystic echinococcosis (CE) are based on imaging complemented by serology. Several immunodiagnostic tests are commercially available, but the development of new tools is still needed to overcome the lack of standardization of the target antigen, generally consisting of a crude extract of Echinococcus granulosus hydatid cyst fluid. In a previous work, we described a chromatographic method for the preparation of a highly enriched Antigen 5 fraction from hydatid cyst fluid. The high reactivity of patient sera against this preparation prompted us to evaluate further this antigen for the serodiagnosis of CE on a larger cohort of samples. A total of 327 sera from CE patients with heterogeneous conditions for cyst stage, cyst number, organ localization, drug therapy, and surgical intervention, together with 253 sera from healthy controls, were first analyzed by an ELISA based on the Ag5 preparation in two different experimental setups and, in parallel, by a commercial ELISA routinely used in clinical laboratories for CE serodiagnosis. The Ag5 ELISAs revealed different sensitivity (88.3% vs 95.3%) without significant differences in specificity (94.1% vs 92.5%), for the two setups, respectively. Moreover, possible relationships between the Ag5 ELISA absorbance results and clinical variables were investigated. Chi squared test, bivariate logistic regression and multiple regression analyses highlighted differences in the serology reactivity according to pharmacological treatment, cyst activity, and cyst number. The two Ag5 ELISAs revealed different performances depending on the setup. The good diagnostic sensitivity and the high reliability of the Ag5 preparation method make this antigen a promising candidate for the serodiagnosis of CE. Further studies will be needed to evaluate the ability of our test to provide useful information on specific CE clinical traits.

  4. Diagnostic Accuracy of Antigen 5-Based ELISAs for Human Cystic Echinococcosis.

    Directory of Open Access Journals (Sweden)

    Daniela Pagnozzi

    2016-03-01

    Full Text Available Clinical diagnosis and follow up of cystic echinococcosis (CE are based on imaging complemented by serology. Several immunodiagnostic tests are commercially available, but the development of new tools is still needed to overcome the lack of standardization of the target antigen, generally consisting of a crude extract of Echinococcus granulosus hydatid cyst fluid. In a previous work, we described a chromatographic method for the preparation of a highly enriched Antigen 5 fraction from hydatid cyst fluid. The high reactivity of patient sera against this preparation prompted us to evaluate further this antigen for the serodiagnosis of CE on a larger cohort of samples.A total of 327 sera from CE patients with heterogeneous conditions for cyst stage, cyst number, organ localization, drug therapy, and surgical intervention, together with 253 sera from healthy controls, were first analyzed by an ELISA based on the Ag5 preparation in two different experimental setups and, in parallel, by a commercial ELISA routinely used in clinical laboratories for CE serodiagnosis. The Ag5 ELISAs revealed different sensitivity (88.3% vs 95.3% without significant differences in specificity (94.1% vs 92.5%, for the two setups, respectively. Moreover, possible relationships between the Ag5 ELISA absorbance results and clinical variables were investigated. Chi squared test, bivariate logistic regression and multiple regression analyses highlighted differences in the serology reactivity according to pharmacological treatment, cyst activity, and cyst number.The two Ag5 ELISAs revealed different performances depending on the setup. The good diagnostic sensitivity and the high reliability of the Ag5 preparation method make this antigen a promising candidate for the serodiagnosis of CE. Further studies will be needed to evaluate the ability of our test to provide useful information on specific CE clinical traits.

  5. Sizing Single Cantilever Beam Specimens for Characterizing Facesheet/Core Peel Debonding in Sandwich Structure

    Science.gov (United States)

    Ratcliffe, James G.

    2010-01-01

    This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.

  6. LDRD final report on microencapsulated immunoreagents for development of one-step ELISA

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C.C.; Singh, A.K.

    1997-08-01

    Microencapsulation of biological macromolecules was investigated as a method for incorporating the necessary immunoreagents into an improved enzyme-linked immunosorbant assay (ELISA) package that would self-develop. This self-contained ELISA package would eliminate the need for a trained technician to perform multiple additions of immunoreagent to the assay. Microencapsulation by insolution drying was selected from the many available microencapsulation methods, and two satisfactory procedures for microencapsulation of proteins were established. The stability and potential for rapid release of protein from these microencapsulates was then evaluated. The results suggest that the chosen method for protein entrapment produces microcapsules with a considerable amount of protein in the walls making these particular microcapsules unsuitable for their intended use.

  7. Comparison of two commercially available anti-HIV ELISAs: Abbott HTLV III EIA and Du Pont HTLV III-ELISA.

    Science.gov (United States)

    Burkhardt, U; Mertens, T; Eggers, H J

    1987-11-01

    Serum specimens were tested for HIV antibodies by two commercially available ELISAs (Abbott HTLV III EIA and Du Pont HTLV III-ELISA). The specificity and sensitivity of these assays were determined by comparison with indirect immunofluorescence and Western blot analysis. Specificity ranged from 94.3% in the Abbott assay to 97.9% in the Du Pont-ELISA. The sensitivity was 100% in the Abbott-ELISA and 99% in the Du Pont test. With both tests, false-positive results occurred predominantly in sera from patients with immunological disorders (kidney transplant recipients, lymphoma, Stevens-Johnson syndrome, etc.), whereas symptomatic AIDS-patients, patients with ARC, and persons with a defined risk for HIV infection could be diagnosed unequivocally. Specificity and sensitivity of anti-HIV ELISAs seemed to depend not only on definition of the cutoff value but also on other factors, such as antigen preparation and inactivation measures. Testing of ELISA-reactive sera by confirmatory tests remains necessary.

  8. Visual distraction and visuo-spatial memory: a sandwich effect.

    Science.gov (United States)

    Tremblay, Sébastien; Nicholls, Alastair P; Parmentier, Fabrice B R; Jones, Dylan M

    2005-01-01

    The functional characteristics of visuo-spatial serial memory and its sensitivity to irrelevant visual information are examined in the present study, through the investigation of the sandwich effect (e.g., Hitch, 1975). The memory task was one of serial recall for the position of a sequence of seven spatially and temporally separated dots. The presence of irrelevant dots interpolated with to-be-remembered dots affected performance over most serial positions (Experiment 1) but that effect was significantly reduced when the interpolated dots were distinct from the to-be-remembered dots by colour and shape (Experiment 2). Parallels are made between verbal and spatial serial memory, and the reduction of the sandwich effect is discussed in terms of the contribution of perceptual organisation and attentional factors in short-term memory.

  9. Residual Strength Prediction of Debond Damaged Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian

    propagation and initiation, as these mechanisms are governing for the overall failure load of the structure. Thus, this presentation will describe the development, validation and application of a FEM based numerical model for prediction of residual strength of damaged sandwich panels. The core......This presentation concerns theoretical and experimental prediction of crack propagation and residual strength of debond damaged sandwich panels. It is evident that in order to achieve highly optimised structures which are able to operate in a stochastic loading environment, damage tolerance...... evaluation based on residual strength prediction is needed. Is a given damage critical for the structural integrity needing immanent repair, or is the damage negligible, where repair can be postponed to the next inspection? These questions are generally interesting for all types of structures...

  10. Intrant ELISA: A Novel Approach to Fabrication of Electrospun Fiber Mat-Assisted Biosensor Platforms and Their Integration within Standard Analytical Well Plates

    Directory of Open Access Journals (Sweden)

    Samira Hosseini

    2016-11-01

    Full Text Available A combination of far-field electrospinning (FFES and free-radical polymerization has been used to fabricate coated electrospun polymer fiber mats as a new type of biosensor platform. Poly (3-hydroxybutyrate-co-3-hydroxyvalerate (PHBV electrospun fibers were dip-coated with different compositions of poly methyl methacrylate-co-methacrylic acid (poly(MMA-co-MAA. This synergistic approach utilizes large specific surface area of PHBV fibers and co-polymer coatings that feature an optimum concentration of surface carboxyl (–COOH groups. The platform surface morphology, porosity and tunable hydrophobicity enhance biomolecular interactions via plurality of molecular forces. These customized fiber mats have been integrated into a newly designed 96-well plate called an “intrant enzyme-linked immunosorbent assay” or i-ELISA. I-ELISA allows colorimetric sandwich assay to be carried out without any modifications or additional steps in ELISA methodology. By introducing the fiber mats in fabrication of i-ELISA via extensions on the lid, we address some of the limitations of the previous designs while demonstrating an enhanced signal intensity up to 12 times higher than that of conventional assays. With improved sensitivity, specificity and accuracy in the detection of dengue virus, i-ELISA has proven to be a reliable platform for biomolecular recognition. The proposed fiber mat-assisted well plate in this study holds great potential as a universal approach for integration of different types of fiber mats with pre-designed specific properties in order to enhance the detection sensitivity of the assay.

  11. Mixed-Mode Delamination Failure Model of Sandwich Plate

    OpenAIRE

    Kormanikova, Eva

    2015-01-01

    Plane fracture of two plies is defined as delamination that can be found between plies in a laminate or sandwich structure. The interface model is solved using fracture and contact mechanics. Within the standard First-Order Deformation Theory of laminates, the mixed-mode delamination failure model is solved. The damage propagation parameters are calculated using the ANSYS code. The delamination problem is solved in a numerical example.

  12. Astronaut Edwin Aldrin makes sandwich in zero gravity conditions

    Science.gov (United States)

    1969-01-01

    Astronaut Edwin E. Aldrin Jr., Apollo 11 lunar module pilot, makes a sandwich in zero gravity conditions in this color reproduction taken from at TV transmission from the Apollo 11 spacecraft during its transearth journey home from the moon. When this picture was made, Apollo 11 was approximately 157,000 nautical miles from earth, traveling at a speed of about 4,300 feet per second.

  13. Fluid Structure Interaction Effect on Sandwich Composite Structures

    Science.gov (United States)

    2011-09-01

    far back as ancient Egyptian times in the use of straw and bricks, or more recently in the last century with the use of steel rebar in concrete ...construction of sandwich composites; however, this particular material was selected for its uniform pattern and translucent qualities after it is wetted out...excellent fire retardant and corrosion resistant qualities making it a natural selection for shipboard applications. The same translucent qualities

  14. Catalytic application of two novel sandwich-type polyoxometalates ...

    Indian Academy of Sciences (India)

    on open-access literatures on the use of the sandwich- type polyoxometalates as catalyst in the synthesis of. 14-aryl or alkyl-14H-dibenzo[a, j]xanthenes. In this study, an attempt was made to explain a facile and efficient synthetic strategy for synthesis of 14-aryl or alkyl-14H-dibenzo[a, j]xanthenes using one-pot con-.

  15. Comparison of two indirect ELISA coating antigens for the detection of dairy cow antibodies against Pasteurella multocida.

    Science.gov (United States)

    Tankaew, Pallop; Srisawat, Wanwisa; Singhla, Tawatchai; Tragoolpua, Khajornsak; Kataoka, Yasushi; Sawada, Takuo; Sthitmatee, Nattawooti

    2018-02-01

    The ELISA is recognized as an efficient diagnostic tool for antibody detection, but there is no standard ELISA assay for detection of antibodies against hemorrhagic septicemia (HS) in cattle. The present study reports on an indirect ELISA assay for antibody detection of HS in dairy cows, and evaluates the sensitivity (Se) and specificity (Sp) of the method using a Bayesian approach. An indirect ELISA was developed with two types of heat extract antigens, Pasteurella multocida strains P-1256 and M-1404, as coating antigens. A checkerboard titration was employed using dairy cow sera immunized with P. multocida bacterin and colostrum-deprived calf sera. The concentrations of heat extract antigen (160μg/mL), sample serum (1:100) and goat anti-bovine immunoglobulin G labeled with horseradish peroxidase (1:2000) were optimal for the assay. The cut-off values were 0.147 and 0.128 for P-1256 and M-1404 coating antigens, and there were no differences in the results of tests with positive and negative sera (p<0.05). The characteristics of three diagnostic tests were evaluated using a one-population Bayesian model, assuming conditional dependence between two types of coating antigen-based ELISAs and indirect hemagglutination assay (IHA). A total of 415 sera samples from dairy cows without HS vaccination and no history of disease were tested. The Se and Sp of the P-1256 and M-1404 ELISAs were higher than those of the IHA. The Se and Sp of the P-1256 ELISA were 90.3% and 90.1%, while the Se and Sp of the M-1404 ELISA were 92.1% and 71.9%. The median values of Se and Sp from the IHA were 36.0% and 58.2%. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Quantum Monte Carlo Study of π-bonded Transition-metal Organometallic Sandwiches

    Science.gov (United States)

    Stich, Ivan; Horvathova, Lucia; Dubecky, Matus; Mitas, Lubos

    2013-03-01

    Accurate quantum Monte Carlo (QMC) calculations enabled us to determine the structure, spin multiplicity, ionization energy, dissociation energy, and spin-dependent electronic gaps of neutral and positively charged vanadium-benzene and cobalt-benzene half-sandwich and sandwich systems. The most intriguing application of these systems is as spin filters. For this purpose we have used a multi-stage combination of techniques with consecutive elimination of systematic biases except for the fixed-node approximation in QMC. The-fixed node approximation was treated at different levels from quantum chemistry (CAS-SCF) to various DFT schemes such as GGA, meta-GGA, hybrid, double-hybrid and local-hybrid functionals. While QMC results indicate a very limited predictive power of mean field DFT methods for this class of systems, QMC results are quite stable with fixed-node approximation based on several classes of DFT orbitals. Our results significantly differ from the established picture based on previous less accurate calculations and point out the importance of high-level many-body methods for predictive calculations of similar transition metal-based organometallic systems. Work supported by APVV-0091-07, APVV-0207-11, LPP-0392-09, and VEGA (2/0007/12) projects, and via CE SAS QUTE. Further support provided by ARO, NSF and DOE.

  17. Identification of honeycomb sandwich properties by high-resolution modal analysis

    Directory of Open Access Journals (Sweden)

    Rebillat M.

    2010-06-01

    Full Text Available A method is proposed to identify the mechanical properties of the skin and core materials of honeycomb sandwich. All the elastic coefficients and loss-factors that matter in the dynamics of a panel in the thick-plate approximation are identified. To this end, experimental natural modes (i.e. eigenmodes of the damped system are compared to the numerical modes of a large sandwich panel (lx,y/h ≃ 80. The chosen generic model for the visco-elastic behaviour of the materials is E (1 + jη. The numerical modes are computed by means of a Rayleigh-Ritz procedure and their dampings are predicted according to the visco-elastic model. The frequencies and dampings of the natural modes of the panel are estimated experimentally by means of a high-resolution modal analysis technique. An optimisation procedure yields the desired coefficients. A sensitivity analysis assess the reliability of the method.

  18. Harmonic Differential Quadrature Analysis of Soft-Core Sandwich Panels under Locally Distributed Loads

    Directory of Open Access Journals (Sweden)

    Xinwei Wang

    2016-11-01

    Full Text Available Sandwich structures are widely used in practice and thus various engineering theories adopting simplifying assumptions are available. However, most engineering theories of beams, plates and shells cannot recover all stresses accurately through their constitutive equations. Therefore, the soft-core is directly modeled by two-dimensional (2D elasticity theory without any pre-assumption on the displacement field. The top and bottom faces act like the elastic supports on the top and bottom edges of the core. The differential equations of the 2D core are then solved by the harmonic differential quadrature method (HDQM. To circumvent the difficulties in dealing with the locally distributed load by point discrete methods such as the HDQM, a general and rigorous way is proposed to treat the locally distributed load. Detailed formulations are provided. The static behavior of sandwich panels under different locally distributed loads is investigated. For verification, results are compared with data obtained by ABAQUS with very fine meshes. A high degree of accuracy on both displacement and stress has been observed.

  19. SIFAT FISIS DAN MEKANIS KOMPOSIT SERAT LIMBAH PATI ONGGOK SANDWICH DENGAN CORE SERAT ACAK DARI BAHAN LIMBAH SEKAM PADI DENGAN MATRIK RESI

    Directory of Open Access Journals (Sweden)

    Ngafwan Ngafwan

    2017-01-01

    Full Text Available Nature composite from skin rice fibre and palm sago fibre have different mechanical and physycs properties characteristic , that have done from result of our researh before. Therefore there is many research that can composse the properties of materials above. The methode of compossing two fiber use poliester that have 20%, 30%, and 40% volume fraction of that matrice, compossing with sandwich layer. Caracterizing properties testing used are thermal conductivity test, and bending test. The result are, at high thermal condition the conductivity was decrease for all above materials. The decreasing of conductivity of this sandwich compsite is more significant. The sandwich composite more tough than skin rice fibre composite. The resume is the mechanical properties ( bending toughness more less significant of the thermal conductivity that more better.

  20. ELISA indireto para detecção de IgG antivírus da doença de Newcastle em soro de codorna Indirect ELISA for the detection of IgG specific to Newcastle disease virus in quail serum

    Directory of Open Access Journals (Sweden)

    D.D. Oliveira

    2007-10-01

    Full Text Available An indirect ELISA for the detection of japanese quail IgG specific to Newcastle disease virus (NDV was developed. The secondary anti-quail IgG was produced in Balb/c mice, by inoculating Freund's complete adjuvant emulsified japanese quail-IgG extract. The purification of IgG was achieved using the caprilic acid method. The ELISA was compared to the haemagglutination-inhibition (HI test for antibodies to NDV. ELISA cut-off point was established through TG-ROC analysis. Total correlation was observed between the ELISA and the HI, being the ELISA efficient in the identification of positive and negative sera, with high sensitivity and specificity (100%. These results validate the use of the indirect ELISA as an alternative for the detection of NDV-specific IgG in japanese quail sera, with the advantage of high sensitivity and automation.

  1. Determinação de carbaril utilizando testes ELISA (Enzyme-linked immunosorbent assay e CLAE com detecção por arranjo de diodos

    Directory of Open Access Journals (Sweden)

    Toscano Ilda A. S.

    2000-01-01

    Full Text Available ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration (žsuperscript three30 mg L-1 and acidic pH conditions (pH 4.0 interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.

  2. Half-sandwich pentamethylcyclopentadienyl group 9 metal ...

    Indian Academy of Sciences (India)

    ... L1= 2-aminopyridine, L2= 2-amino-3-picoline, L3= 2-amino-3-nirtopyridine, and L4= 2-amino-3-pyridine carboxyaldehyde}. The complexes have been characterized by FT-IR, UV-Vis, 1H-13C NMR and mass spectroscopic methods. X-ray crystallographic studies of the complexes have shown typical piano-stool geometry ...

  3. Delamination during drilling in polyurethane foam composite sandwich structures

    Science.gov (United States)

    Sharma, S. C.; Krishna, M.; Narasimha Murthy, H. N.

    2006-06-01

    The objective of this paper is to study the influence of drilling velocity, feed rate, and flank length on the delamination of polyurethane foam sandwich structures. A Taguchi-based design of experiments was used to assess the importance of the drilling parameters, and scanning electron microscopy (SEM) was used to assess the damage from drilling. The drilling of sandwich structures results in significant damage caused by delamination and surface roughness around the drilled holes. The drilling process was evaluated based on a factor called the delamination factor, which is defined as the ratio of the maximum diameter of the damage zone, measured using SEM, to the standard hole diameter (drill diameter). Analysis of variance of the experimental results showed that cutting speed was the most significant parameter among the controllable parameters during drilling of sandwich specimens followed by flank length and feed rate. Finally, confirmation tests were performed to make a comparison between the experimental results and the correlation results. The damage mechanisms are explained using SEM.

  4. Sandwich-structured hollow fiber membranes for osmotic power generation

    KAUST Repository

    Fu, Feng Jiang

    2015-11-01

    In this work, a novel sandwich-structured hollow fiber membrane has been developed via a specially designed spinneret and optimized spinning conditions. With this specially designed spinneret, the outer layer, which is the most crucial part of the sandwich-structured membrane, is maintained the same as the traditional dual-layer membrane. The inner substrate layer is separated into two layers: (1) an ultra-thin middle layer comprising a high molecular weight polyvinylpyrrolidone (PVP) additive to enhance integration with the outer polybenzimidazole (PBI) selective layer, and (2) an inner-layer to provide strong mechanical strength for the membrane. Experimental results show that a high water permeability and good mechanical strength could be achieved without the expensive post treatment process to remove PVP which was necessary for the dual-layer pressure retarded osmosis (PRO) membranes. By optimizing the composition, the membrane shows a maximum power density of 6.23W/m2 at a hydraulic pressure of 22.0bar when 1M NaCl and 10mM NaCl are used as the draw and feed solutions, respectively. To our best knowledge, this is the best phase inversion hollow fiber membrane with an outer selective PBI layer for osmotic power generation. In addition, this is the first work that shows how to fabricate sandwich-structured hollow fiber membranes for various applications. © 2015 Elsevier B.V.

  5. Static and Fatigue Characterization of Nomex Honeycomb Sandwich Panels

    Directory of Open Access Journals (Sweden)

    Keskes Boualem

    2013-07-01

    Full Text Available The main benefits of using the sandwich concept in structural components are the high stiffness, good fatigue resistance and low weight ratios. Recent advances in materials and construction techniques have resulted in further improvement and increased uniformity of the sandwich composite properties. In order to use these materials in different applications, the knowledge of simply their static properties alone is not sufficient but additional information on their fatigue properties and durability are required. In this paper, first static and fatigue tests on four points bending of nomex honeycomb composite sandwich panels have been performed. Load/displacement and S-N fatigue curves are presented and analysed. Fatigue failure and damage modes are observed with an optical microscope and are discussed. The second is to address such fatigue behaviour by using a damage model and check it by experimentation. This fatigue damage model is based on stiffness degradation, which is used as a damage indicator. Two non-linear cumulative damage models derived from the chosen stiffness degradation equation are examined with assumption of linear Miner's damage summation. Predicted results are compared with available experimental data.

  6. Microtomography with a sandwich detector for mouse bone imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Kim, Junwoo; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of); Youn, Hanbean; Jeon, Hosang [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2015-10-15

    Single-shot dual-energy imaging, using sandwich detector, the rear detector usually uses a thicker x-ray converter to enhance quantum efficiency with the higher-energy spectrum, hence providing a blurrier image than the front detector. The weighted logarithmic subtraction of the two images therefore results in a form of unsharp masking that enhances edges in the resultant image. Inspired by this observation, we have developed a micro computed tomography (micro-CT) system with the sandwich detector for high-resolution bone imaging of small animals. The sandwich detector consists of two flat-panel detectors by stacking one upon the other. Although the x-ray beam continuously irradiates, the step-rotation of an object and stay-readout of projection data were considered for the scanning and data gathering. It will be necessary that more elaborate experiments with the mouse and/or other quantitative phantoms. And quantification of the image quality of bone-enhanced images in comparisons with the conventional images will be performed. The image analysis of differences between bone-enhanced images obtained from the projection- and image-based approaches can be performed.

  7. ELISA versus PCR for diagnosis of chronic Chagas disease: systematic review and meta-analysis

    Science.gov (United States)

    2010-01-01

    Background Most current guidelines recommend two serological tests to diagnose chronic Chagas disease. When serological tests are persistently inconclusive, some guidelines recommend molecular tests. The aim of this investigation was to review chronic Chagas disease diagnosis literature and to summarize results of ELISA and PCR performance. Methods A systematic review was conducted searching remote databases (MEDLINE, LILACS, EMBASE, SCOPUS and ISIWeb) and full texts bibliography for relevant abstracts. In addition, manufacturers of commercial tests were contacted. Original investigations were eligible if they estimated sensitivity and specificity, or reliability -or if their calculation was possible - of ELISA or PCR tests, for chronic Chagas disease. Results Heterogeneity was high within each test (ELISA and PCR) and threshold effect was detected only in a particular subgroup. Reference standard blinding partially explained heterogeneity in ELISA studies, and pooled sensitivity and specificity were 97.7% [96.7%-98.5%] and 96.3% [94.6%-97.6%] respectively. Commercial ELISA with recombinant antigens studied in phase three investigations partially explained heterogeneity, and pooled sensitivity and specificity were 99.3% [97.9%-99.9%] and 97.5% [88.5%-99.5%] respectively. ELISA's reliability was seldom studied but was considered acceptable. PCR heterogeneity was not explained, but a threshold effect was detected in three groups created by using guanidine and boiling the sample before DNA extraction. PCR sensitivity is likely to be between 50% and 90%, while its specificity is close to 100%. PCR reliability was never studied. Conclusions Both conventional and recombinant based ELISA give useful information, however there are commercial tests without technical reports and therefore were not included in this review. Physicians need to have access to technical reports to understand if these serological tests are similar to those included in this review and therefore

  8. Mechanical properties and optical testing of metal honeycomb sandwich panel in MTPS

    Science.gov (United States)

    Lu, Jie; Zou, Guang ping; Liang, Jun

    2008-11-01

    Mechanical tests of a Co-based superalloy honeycomb thermal protection system (TPS) panel are finished at room temperature. The lateral tensile limit strength is higher than 59MPa and nearly four multiples of the flatwise compressive strength. Also the modulus in lateral tests are nearly two multiples of the ones under compressive loads. Because of many advantages in application, two optical non-contact methods are introduced in this work to solve different problems of honeycomb sandwich panels. Longitudinal strain of lateral tensile specimens is obtained by digital speckle correlation method (DSCM) and the results of different sub-pixel methods are constrasted. Then the equivalent elastic modulus is calculated further. Electronic speckle shearography pattern interferometry (ESSPI) is presented to obtain the nondestructive results of debonding defects between honeycomb cores and face sheets. Also the size and approximate location are decided real-time. All the results show the two introduced methods are feasible.

  9. Development of fragment-specific osteopontin antibodies and ELISA for quantification in human metastatic breast cancer

    Directory of Open Access Journals (Sweden)

    Miesfeldt Susan

    2008-01-01

    Full Text Available Abstract Background Osteopontin (OPN is associated with human cancers, and circulating blood OPN may have diagnostic or prognostic value in clinical oncology. Methods To evaluate OPN as a cancer biomarker, we generated and characterized five novel mouse monoclonal antibodies against the human full-length OPN (fl-OPN. Epitopes recognized by four antibodies (2C5, 2F10, 2H9, and 2E11 map to N-terminal OPN (aa1-166; one (1F11 maps to C-terminal OPN (aa167-314. These antibodies recognize recombinant and native OPN by ELISA and immunoblot, cross reacting with human and mouse OPN. Two of these novel antibodies (2F10 and 1F11 were used to develop a quantitative enzyme linked immunosorbent assay (ELISA for fl-OPN. Results In comparison with commercially available ELISAs, our assay had high accuracy in measuring fl-OPN standards, and high sensitivity. Specifically, our ELISA has a linear dose response between 0.078 ng/ml-10 ng/ml, with a sensitivity of 13.9 pg/ml. We utilized this assay to quantify fl-OPN in the plasma of healthy volunteers in comparison with patients with metastatic breast cancer. The average circulating plasma fl-OPN in healthy volunteers was 1.2 ng/ml, compared to 4.76 ng/ml in patients with metastatic breast cancer (p = 0.0042. Although the increase in fl-OPN in cancer patients is consistent with previous studies, the measured quantity varied greatly between all existing fl-OPN ELISAs. Conclusion Because OPN is a complex molecule with diversity from alternative splicing, post-translational modification, extracellular proteolytic modification, and participation in protein complexes, we suggest that further understanding of specific isoform recognition of multiple OPN species is essential for future studies of OPN biomarker utility.

  10. Detection of botulinum neurotoxin serotype B at sub mouse LD(50 levels by a sandwich immunoassay and its application to toxin detection in milk.

    Directory of Open Access Journals (Sweden)

    Miles C Scotcher

    2010-06-01

    Full Text Available Botulinum neurotoxin (BoNT, the causative agent of botulism, a serious neuroparylatic disease, is produced by the anaerobic bacterium Clostridium botulinum and consists of a family of seven serotypes (A-H. We previously reported production of high-affinity monoclonal antibodies to BoNT serotype A.Recombinant peptide fragments of the light chain, the transmembrane and receptor-binding domains of the heavy chain of botulinum neurotoxin type B (BoNT/B were expressed in Escherichia coli as GST-fusion proteins and purified. These proteins were used to immunize BALB/cJ mice for the generation of monoclonal antibodies (mAbs. Antibody-producing hybridomas were detected using either a direct binding ELISA binding to plate-immobilized BoNT/B, or with a capture-capture ELISA whereby the capacity of the antibody to capture BoNT/B from solution was tested. A total of five mAbs were selected, two of which bound the toxin light chain and three bound the receptor-binding domain of BoNT/B heavy chain. MAb MCS6-27 was identified via capture-capture ELISA and was the only mAb able to bind BoNT/B in solution under physiological conditions. MAbs F24-1, F26-16, F27-33 and F29-40 were identified via direct binding ELISA, and were able to capture BoNT/B in solution only in the presence of 0.5-0.9 mM sodium dodecyl sulphate (SDS. MAb MCS6-27 and an anti-BoNT/B polyclonal antibody were incorporated into a sandwich ELISA that did not require SDS.We report here the generation of monoclonal antibodies to serotype B and the subsequent development of a sensitive sandwich immunoassay. This immunoassay has a detection limit of 100 fg BoNT/B, fifty times more sensitive than the mouse bioassay detection limit of 5 pg BoNT/B. Additionally, this assay detected as little as 39 pg/mL of toxin in skim, 2% and whole milk.

  11. Novel ELISA for the detection of raw and processed egg using extraction buffer containing a surfactant and a reducing agent.

    Science.gov (United States)

    Watanabe, Yumiko; Aburatani, Kenichi; Mizumura, Tasuku; Sakai, Masatoshi; Muraoka, Shiroo; Mamegosi, Shinichi; Honjoh, Tsutomu

    2005-05-01

    Enzyme-linked immunosorbent assay (ELISA) has been considered extremely useful for the detection of markers of allergenic substances in food, because it is simple, offers a suitable sensitivity, and is useful in providing quantitative results. Allergenic protein present in processed food can be denatured or altered, hindering therefore their possibility to be extracted and detected. This paper reports the development of an ELISA method that can be used for the determination of allergenic proteins in buffer solutions containing SDS, a surfactant, and 2-mercaptoethanol, a reducing agent. Measurement by ELISA in solutions containing 1% SDS and 7% 2-mercaptoethanol has been made possible by using an antibody prepared through immunization with an antigen denatured with SDS and 2-mercaptoethanol. This ELISA technique can be used to measure proteins in food that have been denatured by various manufacturing processes. An example is egg white albumin, which is susceptible to heat denaturation and has been difficult to recover from food in the past. Its recovery was improved 10- to 100-fold by the new ELISA method as compared with previous methods. This means that allergenic substances in food can now be detected quantitatively. This method can be very useful in allergy prevention and control strategies.

  12. Detection of E. coli O157:H7 and Shigella dysenteriae toxins in clinical samples by PCR-ELISA

    Directory of Open Access Journals (Sweden)

    Jafar Amani

    Full Text Available Shiga toxin producing bacteria are potential causes of serious human disease such as hemorrhagic colitis, severe inflammations of ileocolonic regions of gastrointestinal tract, thrombocytopenia, septicemia, malignant disorders in urinary ducts, hemolytic uremic syndrome (HUS Shiga toxin 1 (stx1, shiga toxin 2 (stx2, or a combination of both are responsible for most clinical symptoms of these diseases. A lot of methods have been developed so far to detect shiga toxins such as cell culture, ELISA, and RFPLA, but due to high costs and labor time in addition to low sensitivity, they have not received much attention. In this study, PCR-ELISA method was used to detect genes encoding shiga toxins 1 and 2 (stx1 and stx2. To detect stx1 and stx2 genes, two primer pairs were designed for Multiplex-PCR then PCR-ELISA. PCR products (490 and 275, respectively were subsequently verified by sequencing. Sensitivity and specificity of PCR-ELISA method were determined by using genome serial dilution and Enterobacteriastrains. PCR-ELISA method used in this study proved to be a rapid and precise approach to detect different types of shiga toxins and can be used to detect bacterial genes encoding shiga toxins.

  13. Detection of E. coli O157:H7 and Shigella dysenteriae toxins in clinical samples by PCR-ELISA.

    Science.gov (United States)

    Amani, Jafar; Ahmadpour, Askary; Imani Fooladi, Abbas Ali; Nazarian, Shahram

    2015-01-01

    Shiga toxin producing bacteria are potential causes of serious human disease such as hemorrhagic colitis, severe inflammations of ileocolonic regions of gastrointestinal tract, thrombocytopenia, septicemia, malignant disorders in urinary ducts, hemolytic uremic syndrome (HUS). Shiga toxin 1 (stx1), shiga toxin 2 (stx2), or a combination of both are responsible for most clinical symptoms of these diseases. A lot of methods have been developed so far to detect shiga toxins such as cell culture, ELISA, and RFPLA, but due to high costs and labor time in addition to low sensitivity, they have not received much attention. In this study, PCR-ELISA method was used to detect genes encoding shiga toxins1 and 2 (stx1 and stx2). To detect stx1 and stx2 genes, two primer pairs were designed for Multiplex-PCR then PCR-ELISA. PCR products (490 and 275, respectively) were subsequently verified by sequencing. Sensitivity and specificity of PCR-ELISA method were determined by using genome serial dilution and Enterobacteria strains. PCR-ELISA method used in this study proved to be a rapid and precise approach to detect different types of shiga toxins and can be used to detect bacterial genes encoding shiga toxins. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.

  14. Detection of E. coli O157:H7 and Shigella dysenteriae toxins in clinical samples by PCR-ELISA

    Directory of Open Access Journals (Sweden)

    Jafar Amani

    2015-05-01

    Full Text Available Shiga toxin producing bacteria are potential causes of serious human disease such as hemorrhagic colitis, severe inflammations of ileocolonic regions of gastrointestinal tract, thrombocytopenia, septicemia, malignant disorders in urinary ducts, hemolytic uremic syndrome (HUS. Shiga toxin 1 (stx1, shiga toxin 2 (stx2, or a combination of both are responsible for most clinical symptoms of these diseases. A lot of methods have been developed so far to detect shiga toxins such as cell culture, ELISA, and RFPLA, but due to high costs and labor time in addition to low sensitivity, they have not received much attention. In this study, PCR-ELISA method was used to detect genes encoding shiga toxins1 and 2 (stx1 and stx2. To detect stx1 and stx2 genes, two primer pairs were designed for Multiplex-PCR then PCR-ELISA. PCR products (490 and 275, respectively were subsequently verified by sequencing. Sensitivity and specificity of PCR-ELISA method were determined by using genome serial dilution and Enterobacteria strains. PCR-ELISA method used in this study proved to be a rapid and precise approach to detect different types of shiga toxins and can be used to detect bacterial genes encoding shiga toxins.

  15. Seroprevalence of Toxoplasma gondii in wild kangaroos using an ELISA.

    Science.gov (United States)

    Parameswaran, N; O'Handley, R M; Grigg, M E; Fenwick, S G; Thompson, R C A

    2009-06-01

    Infection with Toxoplasma gondii is a significant problem in Australian marsupials, and can lead to devastating disease and predispose animals to predation. T. gondii infection in kangaroos is also of public health significance due to the kangaroo meat trade. A moderate seroprevalence of T. gondii was observed in a study of western grey kangaroos located in the Perth metropolitan area in Western Australia. Of 219 kangaroos tested, 15.5% (95%CI: 10.7-20.3) were positive for T. gondii antibodies using an ELISA developed to detect T. gondii IgG in macropod marsupials. When compared with the commercially available MAT (modified agglutination test), the ELISA developed was in absolute agreement and yielded a kappa coefficient of 1.00. Of 18 kangaroos tested for the presence of T. gondii DNA by PCR, the 9 ELISA positive kangaroos tested PCR positive and the 9 ELISA negative kangaroos tested PCR negative indicating the ELISA protocol was both highly specific and sensitive and correlated 100% with the more labour intensive PCR assay.

  16. Seroprevalence of Toxoplasma gondii in wild kangaroos using an ELISA

    Science.gov (United States)

    Parameswaran, N.; O'Handley, RM.; Grigg, ME.; Fenwick, SG.; Thompson, RCA.

    2009-01-01

    Infection with Toxoplasma gondii is a significant problem in Australian marsupials, and can lead to devastating disease and predispose animals to predation. T. gondii infection in kangaroos is also of public health significance due to the kangaroo meat trade. A moderate seroprevalence of T. gondii was observed in a study of western grey kangaroos located in the Perth metropolitan area in Western Australia. Of 219 kangaroos tested, 15.5% (95%CI: 10.7-20.3) were positive for T. gondii antibodies using an ELISA developed to detect T. gondii IgG in macropod marsupials. When compared with the commercially available MAT (modified agglutination test), the ELISA developed was in absolute agreement and yielded a κ coefficient of 1.00. Of 18 kangaroos tested for the presence of T. gondii DNA by PCR, the 9 ELISA positive kangaroos tested PCR positive and the 9 ELISA negative kangaroos tested PCR negative indicating the ELISA protocol was both highly specific and sensitive and correlated 100% with the more labour intensive PCR assay. PMID:19567231

  17. Multi-analyte validation in heterogeneous solution by ELISA.

    Science.gov (United States)

    Lakshmipriya, Thangavel; Gopinath, Subash C B; Hashim, Uda; Murugaiyah, Vikneswaran

    2017-12-01

    Enzyme Linked Immunosorbent Assay (ELISA) is a standard assay that has been used widely to validate the presence of analyte in the solution. With the advancement of ELISA, different strategies have shown and became a suitable immunoassay for a wide range of analytes. Herein, we attempted to provide additional evidence with ELISA, to show its suitability for multi-analyte detection. To demonstrate, three clinically relevant targets have been chosen, which include 16kDa protein from Mycobacterium tuberculosis, human blood clotting Factor IXa and a tumour marker Squamous Cell Carcinoma antigen. Indeed, we adapted the routine steps from the conventional ELISA to validate the occurrence of analytes both in homogeneous and heterogeneous solutions. With the homogeneous and heterogeneous solutions, we could attain the sensitivity of 2, 8 and 1nM for the targets 16kDa protein, FIXa and SSC antigen, respectively. Further, the specific multi-analyte validations were evidenced with the similar sensitivities in the presence of human serum. ELISA assay in this study has proven its applicability for the genuine multiple target validation in the heterogeneous solution, can be followed for other target validations. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. [Implementation of the HACCP system in the production line of the traditional sandwich in Phnom Penh City, Cambodia].

    Science.gov (United States)

    Lay, Kruy Sun; Song, Ping; Merch, Keuth; Sakona, Phoeurng; Buisson, Y

    2004-02-01

    From July 2000 to July 2001, the hazard analysis and critical control points (HACCP) system was implemented to the benefit of the traditional sandwich production in Phnom Penh City Sandwiches were initially analyzed for bacterial indicators among 6 large-scale producers during a 2 months period. In the second stage of the study, two selected producers were involved in the HACCP process. Microbiological analyses revealed a poor sanitary quality of samples from all the production lines tested. Implementation of HACCP method resulted in a reduction of microbial contamination, but this decrease was not significant compared with others steps of HACCP process (chi2 test for trend, p > 0.05). HACCP system was well accepted by producers but routine practices and wrong perception by production-line workers did limit the success of the process. A regulation on the mass catering sector should be part of a large strategy of food safety and environmental health in the city.

  19. Standard practice for radiologic examination of flat panel composites and sandwich core materials used in aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice is intended to be used as a supplement to Practices E 1742, E 1255, and E 2033. 1.2 This practice describes procedures for radiologic examination of flat panel composites and sandwich core materials made entirely or in part from fiber-reinforced polymer matrix composites. Radiologic examination is: a) radiographic (RT) with film, b) Computed Radiography (CR) with Imaging Plate, c) Digital Radiology (DR) with Digital Detector Array’s (DDA), and d) Radioscopic (RTR) Real Time Radiology with a detection system such as an Image Intensifier. The composite materials under consideration typically contain continuous high modulus fibers (> 20 GPa), such as those listed in 1.4. 1.3 This practice describes established radiological examination methods that are currently used by industry that have demonstrated utility in quality assurance of flat panel composites and sandwich core materials during product process design and optimization, process control, after manufacture inspection, in service exami...

  20. Data characterizing flexural properties of Al/Al2O3 syntactic foam core metal matrix sandwich

    Directory of Open Access Journals (Sweden)

    Mohammed Yaseer Omar

    2015-12-01

    Full Text Available Microstructural observations and flexural property datasets are provided for aluminum alloy matrix syntactic foam core sandwich composites. The tests are conducted in three-point bending configuration. The data supplied includes methods used for conducting microscopy and mechanical testing. Raw load–displacement data, which is used to plot stress–strain graphs, obtained during the flexural test is also included. Images from a DSLR camera are stitched together to form a detailed failure sequencing video. Failure of specimens is captured in sequential images using a digital camera. These images are stitched together to develop a video for visualization of failure mechanisms. Calculations are also included for a theoretical model that is used to estimate the flexural properties of the syntactic foam core sandwich.

  1. Optimization and validation of ELISA immunoassay for the evaluation of in-vitro relative potency of a four-component human papillomavirus vaccine products.

    Science.gov (United States)

    Mostafa, Moushira M; Al-Ghobashy, Medhat A; Fathalla, Faten A; Salem, Maissa Y

    2016-11-01

    A sandwich-type ELISA was optimized and validated to determine the in-vitro relative potency of the four-component prophylactic Human papillomavirus (HPV) vaccine. The vaccine contains the non-infectious virus like particles (VLP) corresponding to HPV Types 6, 11, 16 and 18. A modification of the desorption step required to release the VLPs from the aluminum adjuvant was carried out. Samples were incubated with citrate buffer for two hours at 37 °C instead of overnight incubation at room temperature. Assay validation was then carried out according to ICH guidelines. The assay was linear over a concentration range of 0.30-2000.00 ng/mL for the four HPV types. The assay was accurate and precise with a LOD of 0.092, 0.081, 0.086 and 0.068 ng/mL for type 6, 11, 16 and 18 respectively. Results were also statistically compared to those obtained using the reported ELISA assay and no significant difference was noted. In contrary to the reported ELISA protocol, this optimized immunoassay was superior with respect to analysis time, without affecting the accuracy and precision (RSD useful for evaluating the efficacy of the quadrivalent HPV vaccine and is applicable for quality control and batch release purposes. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  2. The use of polyvinyl alcohol glutaraldehyde as solid-phase in ELISA for plague

    Directory of Open Access Journals (Sweden)

    Aureci Maria Araujo

    1996-04-01

    Full Text Available Discs of polyvinyl alcohol cross-linked with glutaraldehyde were synthesized under acid catalysis (H2SO4. Then, the antigen F1 purified from Yersinia pestis was covalently linked to this modified polymer. Afterwards, an enzyme-linked immunosorbent assay (ELISA was established for the diagnosis of plague in rabbit and human. The best conditions for the method were achieved by using 1.3 ¼g of F1 prepared in 0.067 M phosphate buffer, pH 7.2, containing 1 M NaCl (PBS; anti-IgG peroxidase conjugate diluted 6,000 times and as a blocking agent 3% w/v skim milk in PBS. The titration of positive rabbit serum according to this procedure detected antibody concentrations up to 1:12,800 times. The present method, the conventional ELISA and passive haemagglutination assay are compared.

  3. Detection of Toxoplasma gondii Antigens in Sera and Urine of Experimentally Infected Mice by Capture ELISA

    Directory of Open Access Journals (Sweden)

    S Shojaee

    2008-04-01

    Full Text Available Background: Toxoplasma gondii is an apicomplexan parasite which infects a broad range of hosts. The classical diagnosis of toxoplasmosis relies on serological methods. Detection of parasite or its components could be useful tool for early diag­nosis of the infection.Methods: Fifty mice were infected by the intraperitoneal route with 5000 tachyzoites of T. gondii RH strain. Five of them sacrificed every day from day 1 up to day 7 post infection. Sera and urine of mice were tested by capture ELISA.Results: T.gondii antigens were detected from 3rd and 2nd day in serum and urine, respectively, after infection until their death on day 7.Conclusion: Antigenemia detection of antigens of parasite was possible in a short period of acute infection with T. gondii by capture ELISA.

  4. ELISA validation and determination of cut-off level for chloramphenicol residues in honey

    Directory of Open Access Journals (Sweden)

    Biernacki Bogumił

    2015-09-01

    Full Text Available An analytical validation of a screening ELISA for detection of chloramphenicol (CAP in honey was conducted according to the Commission Decision 2002/657/EC and Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines. The analyte was extracted from honey with a water and ethyl acetate mixture, and CAP concentrations were measured photometrically at 450 nm. The recovery rate of the analyte from spiked samples was 79%. The cut-off level of CAP in honey as the minimum recovery (0.17 units was established. Detection capability (CCβ was fixed at 0.25 μg kg−1. No relevant interferences between matrix effects and structurally related substances including florfenicol and thiamphenicol were observed. The ELISA method should be useful for determination of CAP residues in honey monitoring.

  5. Research on Effective Electric-Mechanical Coupling Coefficient of Sandwich Type Piezoelectric Ultrasonic Transducer Using Bending Vibration Mode

    Directory of Open Access Journals (Sweden)

    Qiang Zhang

    2015-01-01

    Full Text Available An analytical model on electromechanical coupling coefficient and the length optimization of a bending piezoelectric ultrasonic transducer are proposed. The piezoelectric transducer consists of 8 PZT elements sandwiched between four thin electrodes, and the PZT elements are clamped by a screwed connection between fore beam and back beam. Firstly, bending vibration model of the piezoelectric transducer is built based on the Timoshenko beam theory. Secondly, the analytical model of effective electromechanical coupling coefficient is built based on the bending vibration model. Energy method and electromechanical equivalent circuit method are involved in the modelling process. To validate the analytical model, sandwich type piezoelectric transducer example in second order bending vibration mode is analysed. Effective electromechanical coupling coefficient of the transducer is optimized with simplex reflection technique, and the optimized ratio of length of the transducers is obtained. Finally, experimental prototypes of the sandwich type piezoelectric transducers are fabricated. Bending vibration mode and impedance of the experimental prototypes are tested, and electromechanical coupling coefficient is obtained according to the testing results. Results show that the analytical model is in good agreement with the experimental model.

  6. On the assumption of transverse isotropy of a honeycomb sandwich panel for NDT applications

    Science.gov (United States)

    Schaal, Christoph; Tai, Steffen; Mal, Ajit

    2017-04-01

    Due to their excellent strength-to-weight ratio, honeycomb sandwich panels are being increasingly used in lightweight structures, in particular in aircraft and aerospace industry. Delaminations of individual plies in the composite skins or disbonds of a layer in the multi-layer plate structures often remain undetected during visual inspection. Using guided ultrasonic waves, such hidden defects can be detected. For the successful application of ultrasonic nondestructive testing methods, however, wave propagation characteristics have to be well-understood. Recently developed semi-analytical techniques allow for the calculation of dispersion characteristics for many materials. However, the elastic material behavior is often simplified for these calculations. For example, woven composite laminates are modeled as a homogeneous, transversely isotropic plate. While these simplifications only lead to minor errors, the modeling of aluminum honeycomb core sandwich panels with homogeneous, transversely isotropic layers has yet to be validated. In this paper, an efficient numerical approach is used to determine the dispersion characteristics of a honeycomb core layer with and without simplified material behavior. A full 3D-model, including the honeycomb cells, of a small representative volume element of the material is generated using finite elements, and the resulting dispersion curves are compared to the ones obtained from simplified models. In addition to dispersion curves, the displacement fields of the waves are also analyzed.

  7. Metal-Organic Frameworks (MOFs) as Sandwich Coating Cushion for Silicon Anode in Lithium Ion Batteries.

    Science.gov (United States)

    Han, Yuzhen; Qi, Pengfei; Zhou, Junwen; Feng, Xiao; Li, Siwu; Fu, Xiaotao; Zhao, Jingshu; Yu, Danni; Wang, Bo

    2015-12-09

    A novel metal-organic framework (MOF) sandwich coating method (denoted as MOF-SC) is developed for hybrid Li ion battery electrode preparation, in which the MOF films are casted on the surface of a silicon layer and sandwiched between the active silicon and the separator. The obtained electrodes show improved cycling performance. The areal capacity of the cheap and readily available microsized Si treated with MOF-SC can reach 1700 μAh cm(-2) at 265 μA cm(-2) and maintain at 850 μAh cm(-2) after 50 cycles. Beyond the above, the commercial nanosized Si treated by MOF-SC also shows greatly enhanced areal capacity and outstanding cycle stability, 600 μAh cm(-2) for 100 cycles without any apparent fading. By virtue of the novel structure prepared by the MOFs, this new MOF-SC structure serves as an efficient protection cushion for the drastic volume change of silicon during charge/discharge cycles. Furthermore, this MOF layer, with large pore volume and high surface area, can adsorb electrolyte and allow faster diffusion of Li(+) as evidenced by decreased impedance and improved rate performance.

  8. Sandwich wound closure reduces the risk of cerebrospinal fluid leaks in posterior fossa surgery

    Directory of Open Access Journals (Sweden)

    Verena Heymanns

    2016-07-01

    Full Text Available Posterior fossa surgery is demanding and hides a significant number of obstacles starting from the approach to the wound closure. The risk of cerebrospinal fluid (CSF leakage in posterior fossa surgery given in the literature is around 8%. The present study aims to introduce a sandwich closure of the dura in posterior fossa surgery, which reduces significantly the number of CSF leaks (3.8% in the patients treated in our department. Three hundred and ten patients treated in our hospital in the years 2009-2013 for posterior fossa pathologies were retrospectively evaluated. The dura closure method was as following: lyophilized dura put under the dura and sealed with fibrin glue and sutures, dura adapting stitches, TachoSil® (Takeda Pharma A/S, Roskilde, Denmark, Gelfoam® (Pfizer Inc., New York, NY, USA and polymethylmethacrylate (osteoclastic craniotomy. The incidence of postsurgical complications associated with the dural closure like CSF leakage, infections, bleeding is evaluated. Only 3.8% of patients developed CSF leakage and only 0.5% needed a second surgery for CSF leakage closure. Two percent had a cerebellar bleeding with no need for re-operation and 3% had a wound infection treated with antibiotics. The sandwich wound closure we are applying for posterior fossa surgery in our patients correlates with a significant reduction of CSF leaks compared to the literature.

  9. Experimental and Theoretical Study of Sandwich Panels with Steel Facesheets and GFRP Core

    Directory of Open Access Journals (Sweden)

    Hai Fang

    2016-01-01

    Full Text Available This study presented a new form of composite sandwich panels, with steel plates as facesheets and bonded glass fiber-reinforced polymer (GFRP pultruded hollow square tubes as core. In this novel panel, GFRP and steel were optimally combined to obtain high bending stiffness, strength, and good ductility. Four-point bending test was implemented to analyze the distribution of the stress, strain, mid-span deflection, and the ultimate failure mode. A section transformation method was used to evaluate the stress and the mid-span deflection of the sandwich panels. The theoretical values, experimental results, and FEM simulation values are compared and appeared to be in good agreement. The influence of thickness of steel facesheet on mid-span deflection and stress was simulated. The results showed that the mid-span deflection and stress decreased and the decent speed was getting smaller as the thickness of steel facesheet increases. A most effective thickness of steel facesheet was advised.

  10. External mean flow influence on sound transmission through finite clamped double-wall sandwich panels

    Science.gov (United States)

    Liu, Yu; Catalan, Jean-Cédric

    2017-09-01

    This paper studies the influence of an external mean flow on the sound transmission through finite clamped double-wall sandwich panels lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials and various configurations of coupling the poroelastic layer to the facing plates are considered. The clamped boundary of finite panels are dealt with by the modal superposition theory and the weighted residual (Garlekin) method, leading to a matrix equation solution for the sound transmission loss (STL) through the structure. The theoretical model is validated against existing theories of infinite sandwich panels with and without an external flow. The numerical results of a single incident wave show that the external mean flow has significant effects on the STL which are coupled with the clamped boundary effect dominating in the low-frequency range. The external mean flow also influences considerably the limiting incidence angle of the panel system and the effect of the incidence angle on the STL. However, the influences of the azimuthal angle and the external flow orientation are negligible.

  11. Vibration and Acoustic Response of Rectangular Sandwich Plate under Thermal Environment

    Directory of Open Access Journals (Sweden)

    Yuan Liu

    2013-01-01

    Full Text Available In this paper, we focus on the vibration and acoustic response of a rectangular sandwich plate which is subjected to a concentrated harmonic force under thermal environment. The critical buckling temperature is obtained to decide the thermal load. The natural frequencies and modes as well as dynamic responses are acquired by using the analytical formulations based on equivalent non-classical theory, in which the effects of shear deformation and rotational inertia are taken into account. The rise of thermal load decreases the natural frequencies and moves response peaks to the low-frequency range. The specific features of sandwich plates with different formations are discussed subsequently. As the thickness ratio of facing to core increases, the natural frequencies are enlarged, and the response peaks float to the high-frequency region. Raising the Young's modulus of the core can cause the similar trends. The accuracy of the theoretical method is verified by comparing its results with those computed by the FEM/BEM.

  12. Dynamic response and optimal design of curved metallic sandwich panels under blast loading.

    Science.gov (United States)

    Qi, Chang; Yang, Shu; Yang, Li-Jun; Han, Shou-Hong; Lu, Zhen-Hua

    2014-01-01

    It is important to understand the effect of curvature on the blast response of curved structures so as to seek the optimal configurations of such structures with improved blast resistance. In this study, the dynamic response and protective performance of a type of curved metallic sandwich panel subjected to air blast loading were examined using LS-DYNA. The numerical methods were validated using experimental data in the literature. The curved panel consisted of an aluminum alloy outer face and a rolled homogeneous armour (RHA) steel inner face in addition to a closed-cell aluminum foam core. The results showed that the configuration of a "soft" outer face and a "hard" inner face worked well for the curved sandwich panel against air blast loading in terms of maximum deflection (MaxD) and energy absorption. The panel curvature was found to have a monotonic effect on the specific energy absorption (SEA) and a nonmonotonic effect on the MaxD of the panel. Based on artificial neural network (ANN) metamodels, multiobjective optimization designs of the panel were carried out. The optimization results revealed the trade-off relationships between the blast-resistant and the lightweight objectives and showed the great use of Pareto front in such design circumstances.

  13. Dynamic Response and Optimal Design of Curved Metallic Sandwich Panels under Blast Loading

    Directory of Open Access Journals (Sweden)

    Chang Qi

    2014-01-01

    Full Text Available It is important to understand the effect of curvature on the blast response of curved structures so as to seek the optimal configurations of such structures with improved blast resistance. In this study, the dynamic response and protective performance of a type of curved metallic sandwich panel subjected to air blast loading were examined using LS-DYNA. The numerical methods were validated using experimental data in the literature. The curved panel consisted of an aluminum alloy outer face and a rolled homogeneous armour (RHA steel inner face in addition to a closed-cell aluminum foam core. The results showed that the configuration of a “soft” outer face and a “hard” inner face worked well for the curved sandwich panel against air blast loading in terms of maximum deflection (MaxD and energy absorption. The panel curvature was found to have a monotonic effect on the specific energy absorption (SEA and a nonmonotonic effect on the MaxD of the panel. Based on artificial neural network (ANN metamodels, multiobjective optimization designs of the panel were carried out. The optimization results revealed the trade-off relationships between the blast-resistant and the lightweight objectives and showed the great use of Pareto front in such design circumstances.

  14. A Comparative Study on Damage Mechanism of Sandwich Structures with Different Core Materials under Lightning Strikes

    Directory of Open Access Journals (Sweden)

    Jiangyan Yan

    2017-10-01

    Full Text Available Wind turbine blades are easily struck by lightning, a phenomenon that has attracted more and more attention in recent years. On this subject a large current experiment was conducted on three typical blade sandwich structures to simulate the natural lightning-induced arc effects. The resulting damage to different composite materials has been compared: polyvinyl chloride (PVC and polyethylene terephthalate (PET suffered pyrolysis and cracks inside, while the damage to balsa wood was fibers breaking off and large delamination between it and the resin layer, and only a little chemical pyrolysis. To analyze the damage mechanism on sandwich structures of different materials, a finite element method (FEM model to calculate the temperature and pressure distribution was built, taking into consideration heat transfer and flow expansion due to impulse currents. According to the simulation results, PVC had the most severe temperature and pressure distribution, while PET and balsa wood were in the better condition after the experiments. The temperature distribution results explained clearly why balsa wood suffered much less chemical pyrolysis than PVC. Since balsa wood had better thermal stability than PET, the pyrolysis area of PET was obviously larger than that of balsa wood too. Increasing the volume fraction of solid components of porous materials can efficiently decrease the heat transfer velocity in porous materials. Permeability didn’t influence that much. The findings provide support for optimum material selection and design in blade manufacturing.

  15. Prevalence of antibodies against Entamoeba histolytica in Mexico measured by ELISA

    OpenAIRE

    González, C. R.; Isibasi, A.; Ortiz-Navarrete, V.; Paniagua, J; García, J.A.; Ramirez, A.; Salvatierra, B.; Tapia, R.; Sepúlveda, J.; Gutiérrez, G.; Kumate, J.

    1995-01-01

    The prevalence of antibodies against Entamoeba histolytica was studied in the Mexican population using an immunoenzyme assay in solid phase (ELISA) and semiautomatic equipment. The antigen was a mixture of membrane proteins obtained by Triton X-100 extraction from an axenic culture of Entamoeba histolytica HM1-IMSS. The method was standardized by comparing serum samples from amoebic liver abscess patients with healthy volunteers. From the 60538 samples supplied by the National Seroepidemiolog...

  16. Quantification of fish hepatic metallothioneins, naturally or artificially induced, by ELISA: a comparison with radioimmunoassay and differential pulse polarography

    Energy Technology Data Exchange (ETDEWEB)

    Duquesne, S. [Universite des Sci. et Technol. de Lille, 62 - Wimereux (France). Station Marine; Janquin, M.A. [Universite des Sci. et Technol. de Lille, 62 - Wimereux (France). Station Marine; Hogstrand, C. [Goeteborg Univ. (Sweden). Dept. of Zoophysiology

    1995-07-01

    An ELISA has been developed for the quantification of metallothioneins (MT) in liver from different species of fish. MT has also been quantified by RIA and DPP to allow a comparison between the methods. The immunoassays were carried out with a polyclonal antibody raised against perch (Perca fluviatilis) hepatic MT [1] which cross-reacted with hepatic MT from dab (Limanda limanda), lemon-dab (Microstomus kitt), and cod (Gadus morhua). The ELISA was more sensitive for the detection of MT from the flatfish than RIA and DPP. The detection limits of MT by immunoassays were lower for fish caught in the field than for Cd-injected fish. The immunoreactivity differed between MT from different fish species, more markedly between fish MT and rabbit MT. MT values determined by the three methods have been compared and showed that the results were similar and significantly correlated. Advantages and disadvantages of the ELISA are discussed in relation to the other methods. (orig.)

  17. ELISA FOR BOVINE SCHISTOSOMIASIS VACCINE EVALUATION: A PRELIMINARY REPORT

    Directory of Open Access Journals (Sweden)

    Imadeldin Elamin Aradaib

    1994-12-01

    Full Text Available Six calves were immunized with schistosomula of Schistosoma bovis irradiated at 3 or 20 Kilorad (Krad and three calves were kept as controls. Twenty four weeks post immunization, three calves (one from the 20 Krad and two from the 3 Krad group were challenged with normal cercaria of S. bovis. The immune response was monitored by agar gel immunodiffusion (AGID and the Enzyme Linked Immunosorbent Assay (ELISA using adult worm antigen. Using AGID, precipitin lines were observed only with sera from challenged animals. Using ELISA, the immune response of the vaccinated calves was first detected by 2-3 weeks, peaking by 6-8 weeks post vaccination. The immune response of the three challenged calves was elevated by 2 weeks post challenge, peaking at 8-10 weeks post challenge and remained high throughout the experimental period. This study suggests that ELISA could be used for diagnosis of bovine schistosomiasis.

  18. Influence of baking time and matrix effects on the detection of milk allergens in cookie model food system by ELISA.

    Science.gov (United States)

    Monaci, Linda; Brohée, Marcel; Tregoat, Virginie; van Hengel, Arjon

    2011-07-15

    Milk allergens are common allergens occurring in foods, therefore raising concern in allergic consumers. Enzyme-linked immunosorbent assay (ELISA) is, to date, the method of choice for the detection of food allergens by the food industry although, the performance of ELISA might be compromised when severe food processing techniques are applied to allergen-containing foods. In this paper we investigated the influence of baking time on the detection of milk allergens by using commercial ELISA kits. Baked cookies were chosen as a model food system and experiments were set up to study the impact of spiking a matrix food either before, or after the baking process. Results revealed clear analytical differences between both spiking methods, which stress the importance of choosing appropriate spiking methodologies for method validation purposes. Finally, since the narrow dynamic range of quantification of ELISA implies that dilution of samples is required, the impact of sample dilution on the quantitative results was investigated. All parameters investigated were shown to impact milk allergen detection by means of ELISA. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Applicability of ELISA to screen for dioxin-like PCBs in retail fish

    Energy Technology Data Exchange (ETDEWEB)

    Tsutsumi, T.; Amakura, Y.; Sasaki, K.; Maitani, T. [National Institute of Health Sciences, Tokyo (Japan); Okuyama, A.; Mizukami, H. [EnBioTec Laboratories Co., Ltd., Tokyo (Japan); Tanioka, Y.; Ueda, K.; Sakata, K. [Daiichi Fine Chemical Co., Ltd., Toyama (Japan)

    2004-09-15

    The group of dioxin-like PCBs, consisting of four non-ortho PCBs and eight mono-ortho PCBs, is classified among the dioxins. Humans are considerably exposed to dioxin through consumption of fish in Japan. The TEQ contribution of dioxin-like PCBs in fish is dominant, contributing about 70% of the total TEQ. Therefore, it is important to reveal TEQ levels of dioxin-like PCBs as well as PCDD/Fs in retail fish. HRGC/HRMS is currently the most widely used method to determine levels of dioxin-like PCBs. This method is very reliable and highly sensitive, but it is also timeconsuming and requires expensive equipment and highly trained analysts. One possible alternative method for screening dioxin-like PCBs is a bioassay, such as an ELISA. We recently developed an ELISA kit using a monoclonal antibody (MAb) specific to 2,3{sup '},4,4{sup '},5-pentachlorobiphenyl (PCB 118). PCB 118 is generally the most abundant isomer among dioxin-like PCBs in fish, although it has a relatively small contribution to the total TEQ derived from dioxin-like PCBs. Based on our HRGC/HRMS data, we found that the concentrations of PCB 118 correlated well to the TEQ levels of dioxin-like PCBs in retail fish (r>0.85, n = 181). Here, we examined the application of the ELISA kit in determining TEQ levels of dioxin-like PCBs in retail fish.

  20. Comparison of an ELISA assay for the detection of adhesive/invasive Neospora caninum tachyzoites

    Directory of Open Access Journals (Sweden)

    Luiz Miguel Pereira

    Full Text Available Neospora caninum belongs to the phylum Apicomplexa, the causative agent of neosporosis, which leads to economic impacts on cattle production. A common feature among apicomplexan parasites is the invasive process driven mostly by the parasite. As a first evaluation of candidate molecules that play a possible role by interfering in this invasive process, the in vitro invasion assay is a fast and direct way to screen future agonists or antagonists. This work involved the development of a new cell culture ELISA and transient β-galactosidase activity applied to the semi-quantitative detection of N. caninum in Vero cell culture. Cell culture ELISA is based on histochemistry and immunology, resulting in a colorimetric reaction. The β-galactosidase activity was obtained by the transient transfection of the lacZ gene under control of RPS13 promoter of N. caninum. These methods were used to evaluate the effects of temperature (37°C and 85°C on the invasion and adhesion of tachyzoites. The three tested methods (real time PCR, β-galactosidase activity and ELISA showed a similar pattern, indicating that different methods may be complementary.

  1. Monitoring of atrazine in milk using a rapid tube-based ELISA and validation with HPLC.

    Science.gov (United States)

    Barchanska, Hanna; Jodo, Elzbieta; Price, Robert Graham; Baranowska, Irena; Abuknesha, Ramadan

    2012-06-01

    Although atrazine has been banned in the European Union since 2007 it still persists in soil from where it can enter the food chain. Milk-producing animals accumulate atrazine from contaminated feed and water and since large quantities of milk and milk products are consumed its quality should be constantly monitored. The objective of this investigation was to develop a simple tube ELISA procedure suitable for use in non-specialised laboratories and in the field. A polyclonal antibody raised in sheep and the hapten-gelatine conjugate was immobilised onto polystyrene tubes. This enables the colour produced to be read on a basic spectrophotometer. Milk samples were collected from three farms in different regions of Poland and diluted before immunoassay was performed. Samples were extracted with hexane-acetone for HPLC analysis. The amount of fat in the milk samples interferes with the dose response so it essential that the standards are prepared in the same samples matrix. A good correlation between 1% and 2% was found between the two methods in the analysis of real samples. However the ELISA procedure was more sensitive that the HPLC method since atrazine was detected in some samples by the ELISA but was not confirmed by the HPLC method. The study demonstrated that the simple antigen-coated tube assay provides a cost effective and valuable screening test that can be easily modified for direct use as a screening tool in the field. Copyright © 2012. Published by Elsevier Ltd.

  2. Retratos falados em Elisa Lispector: um álbum fragmentado

    Directory of Open Access Journals (Sweden)

    André de Souza Pinto

    2015-11-01

    Full Text Available Este artigo, ao selecionar Retratos antigos: esboços a serem ampliados, de Elisa Lispector, teve como objetivo analisar a existência de um discurso fragmentado e memorialístico, assim como a construção, por intermédio dos retratos familiares, de uma autobiografia de Elisa e de sua família. Assim, o principal objetivo desse artigo foi apresentar a história dos Lispector feita por fotografias esquecidas em um velho álbum.

  3. Development and evaluation of an indirect ELISA for detection of exfoliative toxin ExhA, ExhB or ExhC produced by Staphylococcus hyicus

    DEFF Research Database (Denmark)

    Andresen, Lars Ole

    1999-01-01

    , one from each of the 69 pig herds with outbreak of exudative epidermitis. Toxigenic S. hyicus were detected in 74% of the cases by ELISA. From each of the five cases, in which initially no toxigenic S. hyicus were found, a further 40 S. hyicus-like colonies were tested in ELISA. Testing of this number......Immunoblot analysis and enzyme-linked immunosorbent assay (ELISA) confirmed previous reports that the Staphylococcus hyicus exfoliative toxins ExhA and ExhB are metalloproteins, and further indicated that ExhC is also a metalloprotein. An indirect ELISA. was developed for the detection of toxigenic...... strains as an alternative method to the use of phage typing for selection of S. hyicus isolates to be used in autogenous vaccine against exudative epidermitis in pigs. The indirect ELISA was evaluated by investigating the presence of toxin among a total of 655 S. hyicus isolates from 69 pig skin samples...

  4. Screening for protein-DNA interactions by automatable DNA-protein interaction ELISA.

    Directory of Open Access Journals (Sweden)

    Luise H Brand

    Full Text Available DNA-binding proteins (DBPs, such as transcription factors, constitute about 10% of the protein-coding genes in eukaryotic genomes and play pivotal roles in the regulation of chromatin structure and gene expression by binding to short stretches of DNA. Despite their number and importance, only for a minor portion of DBPs the binding sequence had been disclosed. Methods that allow the de novo identification of DNA-binding motifs of known DBPs, such as protein binding microarray technology or SELEX, are not yet suited for high-throughput and automation. To close this gap, we report an automatable DNA-protein-interaction (DPI-ELISA screen of an optimized double-stranded DNA (dsDNA probe library that allows the high-throughput identification of hexanucleotide DNA-binding motifs. In contrast to other methods, this DPI-ELISA screen can be performed manually or with standard laboratory automation. Furthermore, output evaluation does not require extensive computational analysis to derive a binding consensus. We could show that the DPI-ELISA screen disclosed the full spectrum of binding preferences for a given DBP. As an example, AtWRKY11 was used to demonstrate that the automated DPI-ELISA screen revealed the entire range of in vitro binding preferences. In addition, protein extracts of AtbZIP63 and the DNA-binding domain of AtWRKY33 were analyzed, which led to a refinement of their known DNA-binding consensi. Finally, we performed a DPI-ELISA screen to disclose the DNA-binding consensus of a yet uncharacterized putative DBP, AtTIFY1. A palindromic TGATCA-consensus was uncovered and we could show that the GATC-core is compulsory for AtTIFY1 binding. This specific interaction between AtTIFY1 and its DNA-binding motif was confirmed by in vivo plant one-hybrid assays in protoplasts. Thus, the value and applicability of the DPI-ELISA screen for de novo binding site identification of DBPs, also under automatized conditions, is a promising approach for a

  5. Development of an Indirect ELISA Using Different Fragments of Recombinant Ncgra7 for Detection of Neospora caninum Infection in Cattle and Water Buffalo

    Science.gov (United States)

    HAMIDINEJAT, Hossein; SEIFI ABAD SHAPOURI, Massoud Reza; NAMAVARI, Mohammad Mehdi; SHAYAN, Parviz; KEFAYAT, Marzieh

    2015-01-01

    Background: Dense granules are immunodominant proteins for the standardization of immunodiagnostic procedures to detect neosporosis. In the presented study different fragment of a dense-granule protein was evaluated for serodiagnosis of Neospora caninum in cattle and water buffalo. Methods: NcGRA7, from N. caninum tachyzoites was amplified. PCR product and pMAL-c2X plasmid were digested with EcoR1 restriction enzyme and expressed in Escherichia coli to evaluate its competence for detection of anti- N. caninum antibodies with ELISA in comparison with commercial IDEXX ELISA. Furthermore, 230 sera of presumably healthy cattle and water buffaloes (108 cattle and 122 water buffaloes) were analyzed by both tests to determine the agreement of these two procedures. Results: Sensitivities and specificities of NcGRA7-based ELISA were 94.64% and 90.38% respectively using sera of cattle, but were 98.57% and 86.54% in the case of buffaloes respectively. A good correlation between the results of IDEXX ELISA and ELISA based on recombinant NcGRA7 for detecting N. caninum antibodies was appeared. Analyzing by Mc Nemar′s showed that NcGRA7-based ELISA has acceptable capability to differentiate the positive results in comparison with IDEXX ELISA. Conclusion: NcGRA7-based ELISA considering utilized new fragment of genomic DNA is a good tool for serodiagnosis of anti- N. caninum antibodies for screening and epidemiological purposes on cattle herd and water buffaloes as well. PMID:25904948

  6. Development of a rapid chemiluminescent ciELISA for simultaneous determination of florfenicol and its metabolite florfenicol amine in animal meat products.

    Science.gov (United States)

    Tao, Xiaoqi; Yu, Xuezhi; Zhang, Dongdong; Shi, Weimin; Jiang, Haiyang; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Xia, Xi; Shen, Jianzhong

    2014-01-30

    A rapid one-step chemiluminescent competitive indirect enzyme-linked immunosorbent assay (CL-ciELISA) for florfenicol (FF) and its major metabolite florfenicol amine (FFA) residues in animal meat products has been developed. The 50% binding inhibition (IC₅₀) values of the method were 0.195 µg kg⁻¹ for FFA and 0.24 µg kg⁻¹ for FF under optimum conditions. The cross-reactive rates for FF and FFA were 100.0% and 81.2%, respectively. FF and FFA were easily extracted from animal meat product with an FF/FFA extraction buffer, obtaining recoveries of 81.8-92.0% (FF) and 77.2-100% (FFA). The whole one-step CL-ciELISA test can be accomplished within 40 min in theory. The detection limits (LODs) of the assay were 0.98 µg kg⁻¹ for FF and 0.80 µg kg⁻¹ for FFA in animal meat samples. Finally, field animal meat samples were analyzed with the CL-ciELISA method, and the results correlated well with those obtained using traditional ELISA and a previously reported liquid chromatographic-tandem mass spectrometric method. The combined results confirmed the utility of this faster one-step CL-ciELISA for simultaneous trace analysis of FF and FFA. To date, this is the most rapid developed ELISA and CL-ELISA method for detection of FF and FFA. © 2013 Society of Chemical Industry.

  7. Finite element simulation of low velocity impact loading on a sandwich composite

    OpenAIRE

    Vishwas M.; Joladarashi Sharnappa; Kulkarni Satyabodh M.

    2018-01-01

    Sandwich structure offer more advantage in bringing flexural stiffness and energy absorption capabilities in the application of automobile and aerospace components. This paper presents comparison study and analysis of two types of composite sandwich structures, one having Jute Epoxy skins with rubber core and the other having Glass Epoxy skins with rubber core subjected to low velocity normal impact loading. The behaviour of sandwich structure with various parameters such as energy absorption...

  8. Precast/Prestressed Concrete Experiments Performance on Non-Load Bearing Sandwich Wall Panels

    Science.gov (United States)

    2011-01-01

    AFRL-RX-TY-TR-2011-0021 PRECAST/ PRESTRESSED CONCRETE EXPERIMENTS PERFORMANCE ON NON-LOAD BEARING SANDWICH WALL PANELS Clay J. Naito...2008 -- 20-NOV-2010 Precast/ Prestressed Concrete Experiments Performance on Non-Loadbearing Sandwich Wall Panels FA8903-08-D-8768-0002 99999F GOVT F0...Wall Construction [TCA 2006] .............................................. 5 3. Prestressed Concrete Sandwich Wall Construction [PCI 1997

  9. Effects of Subzero Temperatures and Sea Water Immersion on Damage Initiation and Growth in Sandwich Composites

    Science.gov (United States)

    2008-12-10

    single cantilever beam sandwich test. The TSD is perhaps 19 An improved methodology for measuring the interracial toughness of sandwich beams 3...measuring the interracial toughness of sandwich beams 5 Table 4.1. Material properties Glass face Glass face Carbon „ , ,, Loading L...which shows the relationship between reaction forces for an MSCB specimen with 12 ply glass face sheets at different crack lengths. It is observed

  10. Sandwich-format ECL immunosensor based on Au star@BSA-Luminol nanocomposites for determination of human chorionic gonadotropin.

    Science.gov (United States)

    Zhang, Amin; Guo, Weiwei; Ke, Hong; Zhang, Xin; Zhang, Huan; Huang, Chusen; Yang, Dapeng; Jia, Nengqin; Cui, Daxiang

    2018-03-15

    A sandwich-configuration electrochemiluminescence (ECL) immunosensor based on Au star@BSA-Luminol nanocomposites for ultrasensitive determination of human chorionic gonadotropin (HCG) has been developed. In this work, nanostructured Polyaniline hydrogels (Pani) decorated with Pt nanoparticles (Pani/Pt) were utilized to construct the base of this immunosensor, greatly increasing the amount of loaded capture antibodies (Ab1) via linkage reagent glutaraldehyde (GA). The used conducting Pani/Pt nanocomposites possessed the unique features, such as large surface area, high electron transfer speed and favorable electrocatalytic activities of hydrogen peroxide, which offered a prominent platform for this sandwich-sensor and acted as efficient ECL signal amplifier also. Furthermore, we employed horseradish peroxidase (HRP) to block the nonspecific binding sites instead of commonly used bovine serum albumin (BSA), which further amplified the signal of luminol in the present of hydrogen peroxide (H2O2). In addition, Au star@BSA nanocomposites with excellent water solubility, low-toxicity and great biocompatibility were prepared and used to immobilize HCG detection antibodies (Ab2) and luminescent material luminol. Then, the above-synthetized Luminol-Au star@BSA-Ab2 complex was attached to the modified sensor by sandwiched immunoreactions. Under the optimized conditions, the proposed immunosensor exhibited a sensitive detection of HCG in a wide linear range from 0.001 to 500mIUmL-1 with a detection limit of 0.0003mIU/mL (S/N = 3). All the results indicated that such a sandwiched HCG immunosensor exhibited favorable ECL analytical performance. This developed method may be potentially used to recognize other clinical protein and display a novel ideal to construct an immunosensor. Copyright © 2017. Published by Elsevier B.V.

  11. Application of sandwich honeycomb carbon/glass fiber-honeycomb composite in the floor component of electric car

    Science.gov (United States)

    Sukmaji, I. C.; Wijang, W. R.; Andri, S.; Bambang, K.; Teguh, T.

    2017-01-01

    Nowadays composite is a superior material used in automotive component due to its outstanding mechanical behavior. The sandwich polypropylene honeycomb core with carbon/glass fiber composite skin (SHCG) as based material in a floor component of electric car application is investigated in the present research. In sandwich structure form, it can absorb noise better compare with the conventional material [1]. Also in present paper, Finite Element Analysis (FEA) of SHCG as based material for floor component of the electric car is analyzed. The composite sandwich is contained with a layer uniform carbon fiber and mixing non-uniform carbon-glass fiber in upper and lower skin. Between skins of SHCG are core polypropylene honeycomb that it have good flexibility to form following dies profile. The variables of volume fraction ratio of carbon/glass fiber in SHCG skin are 20/80%, 30/70%, and 50/50%. The specimen of SHCG is tested using the universal testing machine by three points bending method refers to ASTM C393 and ASTM C365. The cross point between tensile strength to the volume fraction the mixing carbon/glass line and ratio cost line are the searched material with good mechanical performance and reasonable cost. The point is 30/70 volume fraction of carbon/glass fiber. The result of the testing experiment is become input properties of model structure sandwich in FEA simulation. FEA simulation approach is conducted to find critical strength and factor of complex safety geometry against varied distributed passenger loads of a floor component the electric car. The passenger loads variable are 80, 100, 150, 200, 250 and 300 kg.

  12. Vibro-acoustic topology optimization of sandwich panels partially treated with MR fluid and silicone rubber core layer

    Science.gov (United States)

    Hemmatian, Masoud; Sedaghati, Ramin

    2017-12-01

    This study aims to investigate the topology optimization of sandwich panels partially treated with magnetorheological (MR) fluid and silicone rubber core layer. The finite element (FE) model of the partially treated sandwich panel has been developed using circular and 4-node quadrilateral elements. The FE model is then utilized to solve the free and forced vibration equations of motion to obtain the natural frequencies, loss factors and sound transmission loss (STL), respectively. Systematic parametric studies on the effect of the position of the MR fluid and silicone rubber on the first axisymmetric natural frequency, the corresponding loss factor and also the STL are presented. It has been shown that the vibrational and acoustical behavior of the sandwich panel changes considerably as the location of the MR treatment changes. To conduct optimization problems efficiently without using the full FE model, linear meta-models have been derived using random and D-optimal design points. The developed meta-models are then utilized to solve the topology optimization problems using the genetic algorithm and integer programing methods. The suitability of the identified optimal candidates are further evaluated using the developed FE model to determine the optimized topology for the constraint and unconstraint problems.

  13. Performance of Pre-Stressed Sandwich Composites Subjected to Shock Wave Loading

    Directory of Open Access Journals (Sweden)

    Shukla A.

    2010-06-01

    Full Text Available The present paper experimentally studies the dynamic behaviour of prestressed sandwich composites under blast loading. The in-plane static compression loadings are implemented on the sandwich composites before they are subjected to the transverse shock wave loading. Three different pre-stress levels are chosen. 3-D realtime deformation data are captured by two high-speed photography systems: a backview Digital Image Correlation (DIC system and a side-view camera system. The results show that pre-stresses can induce local buckling in the front face-sheet of sandwich composites, consequently reduce the blast resistance of sandwich composites.

  14. Mechanical evaluation with fe analysis of sandwich panels for wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Yasaswi, M.; Naveen, P.N.E.; Prasad, R.V. [GIET. Dept. of Mechanical Engineering, Rajahmundry (India)

    2012-07-01

    Sandwich panels are notable for their structural efficiency and are used as load bearing components in various branches of engineering, especially in aerospace and marine industries. The objective of the present work is to perform computer-aided analysis on sandwich panels. The analysis of sandwich panel with truss core are compared with other four types of sandwich panel with continuous corrugated core, top hat core, zed core and channel core. The basic reason to use sandwich structure is to save weight, however smooth skins and excellent fatigue resistance are also attributes of a sandwich structure. A sandwich is comprised of two layered composite materials formed by bonding two or more thin facings or face sheets to relatively thick core materials. In this type of construction the facings resist nearly all of the in-plane loads and out-of-plane bending moments. The thin facings provide nearly all of the bending stiffness because they are generally of a much higher modulus material is located at a greatest distance from the neutral axis of the component. The basic concept of sandwich panel is that the facings carry the bending loads and the core carries the shear loads. The main function of the core material is to distribute local loads and stresses over large areas. From all this analysis it is concluded that the truss core Sandwich panels can be used in wind turbine blade design. (Author)

  15. Stable high-order molecular sandwiches: Hydrocarbon polyanion pairs with multiple lithium ions inside and out

    Energy Technology Data Exchange (ETDEWEB)

    Ayalon, A.; Rabinovitz, M. (Hebrew Univ. of Jerusalem (Israel)); Sygula, A.; Rabideau, P.W. (Louisiana State Univ., Baton Rouge, LA (United States)); Cheng, P.C.; Scott, L.T. (Boston College, Chestnut Hill, MA (United States))

    1994-08-19

    Stable ten-component sandwich compounds have been characterized in which four lithium ions reside between two tetraanions derived from corannulene or its alkyl-substituted derivatives and four additional lithium ions decorate the exterior. In tetrahydrofuran solution, the four lithium ions inside the sandwich can exchange environments with the four external lithium atoms, but the two tetraanion decks of the sandwich never separate from one another on the time scale of nuclear magnetic resonance. Theoretical calculations point to a [open quotes]stacked bowl[close quotes] conformation and a low energy barrier for synchronous double inversion of the tetraanion bowls in the solvated sandwich compounds.

  16. Amperometric Detection of Bacillus anthracis Spores: A Portable, Low-Cost Approach to the ELISA

    Directory of Open Access Journals (Sweden)

    Gabriel D. Peckham

    2013-01-01

    Full Text Available Antibody-based detection assays are generally robust, a desirable characteristic for in-the-field use. However, to quantify the colorimetric or fluorescent signal, these assays require expensive and fragile instruments which are ill-suited to in-the-field use. Lateral flow devices (LFDs circumvent these barriers to portability but suffer from poor sensitivity and subjective interpretation. Here, an antibody-based method for detecting Bacillus anthracis spores via amperometric signal generation is compared to ELISA and LFDs. This amperometric immunoassay uses antibody conjugated to magnetic beads and glucose oxidase (GOX along with the electron mediator 2, 6-dichlorophenolindophenol (DCPIP for production of a measurable current from a 0.4 V bias voltage. With similar sensitivity to ELISA, the assay can be completed in about 75 minutes while being completely powered and operated from a laptop computer. Immunoassay amperometry holds promise for bringing low-cost, quantitative detection of hazardous agents to the field.

  17. Parvovirus antibodies in vaccinated gilts in field conditions--results with HI and ELISA tests.

    Science.gov (United States)

    Oravainen, J; Hakala, M; Rautiainen, E; Veijalainen, P; Heinonen, M; Tast, A; Virolainen, J V; Peltoniemi, O A T

    2006-02-01

    This study was conducted to determine the antibody response for porcine parvovirus (PPV) of 39 gilts in field conditions after vaccination. Gilts from four herds endemically infected with PPV were injected twice with a commercial vaccine of inactivated PPV and Erysipelothrix rhusiopathiae. The PPV antibodies were analysed both with haemagglutination inhibition (HI) and enzyme-linked immunosorbent assay (ELISA) in order to study the agreement between these methods. The possible association between high-antibody titres and reproductive failure (repeat breeding, culling for infertility, gilts (84.6%) had not seroconverted by the age of 6 months. On-field vaccination resulted in a consistent increase of humoral immunity not exceeding the antibody level of 1 : 512 in the majority of gilts in all herds examined. The agreement between ELISA and HI tests was moderate (Spearman's rho = 0.87, kappa = 0.63). The seroconversion over the level >1:512 by mid-pregnancy was not associated with reproductive failure.

  18. Methodology for determination of plasma cortisol in fish using Competitive Enzyme-Linked Immunosorbent Assay (ELISA)

    DEFF Research Database (Denmark)

    Velasco-Santamaría, Yohana M.; Cruz-Casallas, Pablo E.

    2007-01-01

    Objective. To determine plasma cortisol procedure in fish using competitive enzymelinked immunosorbent assay (ELISA). Materials and methods. Two plasma samples of juveniles rainbow trout Oncorhynchus mykiss were analized by using ELISA human kit for cortisol assay. For standard curve calibration...... seven standard solutions of cortisol in human plasma (0, 20, 50, 100, 200, 400 and 800 ng.ml-1) were used. For the recovery test 50, 100 and 200 ng.ml-1 standard solutions of cortisol were used; for the linearity test four dilutions of the fish plasma samples (1/2, 1/4, 1/8 and 1/16) were prepared...... procedure was assessed previously. The recovery and linearity percentages, the standard curve and parallelism were determined. Results. The standard curve showed a high correlation coefficient (r2 = 0.998). The cortisol concentration of two samples fluctuated between 64 and 72 ng.ml-1. Only the 200 ng.ml-1...

  19. Prevalence of antibodies against Entamoeba histolytica in Mexico measured by ELISA

    Science.gov (United States)

    González, C. R.; Isibasi, A.; Ortiz-Navarrete, V.; Paniagua, J.; García, J. A.; Ramirez, A.; Salvatierra, B.; Tapia, R.; Sepúlveda, J.; Gutiérrez, G.; Kumate, J.

    1995-01-01

    The prevalence of antibodies against Entamoeba histolytica was studied in the Mexican population using an immunoenzyme assay in solid phase (ELISA) and semiautomatic equipment. The antigen was a mixture of membrane proteins obtained by Triton X-100 extraction from an axenic culture of Entamoeba histolytica HM1-IMSS. The method was standardized by comparing serum samples from amoebic liver abscess patients with healthy volunteers. From the 60538 samples supplied by the National Seroepidemiology Survey, antibodies were found in 4·49% (4·32—4·65% at 95% confidence limit). More significant titres occurred in the central region of the country. The ratio female to male was 1·25:1. The population living in metropolitan areas had probably been infected at a younger age than those living in the country. Important differences were found in the seroprevalence obtained by ELISA compared with a study which used indirect haemagglutination (IHA) in the same sample frame. PMID:8557086

  20. ELISA and GEOMORF environmental codes. ELISA e GEOMORF: Un sistema informativo territoriale ambientale e un applicativo ideografico come sua evoluzione

    Energy Technology Data Exchange (ETDEWEB)

    Gigli, C.; Miniero, O.; Grauso, S.; Polizzano, C.; Aurelio, V.; Oliveri, F.; Marzocchi, S.

    1991-04-01

    ELISA (Environmental Land Information System Application), based on GIS (Geographical Information System), allows the complete and integrated management of a hierarchical structure of water resources. The GEOMORF code was developed with the cooperation of ENEA (Italian Commission on Nuclear and Alternative Energy Sources) as a functional module of the ELISA system software for the automatic calculation of the geomorphological parameters of hydrographical systems, the tabling of the relevant data, the production of ipsometrical curves, thematic charts, etc. One of the more innovative aspects of this code is its ability to provide graphic imaging through integration with a digital, raster model of the ground.