WorldWideScience

Sample records for sand-packed column tests

  1. Fluoride retardation from quartz sand-packed column tests

    Directory of Open Access Journals (Sweden)

    Eduardo Usunoff

    2009-06-01

    Full Text Available Inasmuch as both low and high concentrations of F- in groundwater have different detrimental effects on human health (increased dental caries, and mottled enamel or even severe structural bone deformations, respectively, many efforts have focused on the movement of such anion in aqueous systems. It is so because water drinking is the main intake of F- by humans. This paper presents the results of seven dynamic experiments in which solutions of varying [F-], pH, and flow velocities circulated through columns packed with clean quartz sand. The breakthrough data were analyzed by means of a computer code adapted to the estimation of equilibrium and non-equilibrium solute transport parameters from miscible displacement experiments in a steady-state, uniform flow field using a pulse-type or continuous source. It was found that larger retardation factors (R are associated with low pH, low [F-] in the feed solutions, and larger flow velocities. Such results appear to be related to the form of the F species, the rather weak bond between the adsorbate and the quartz sand, and stronger anion repulsion at low pore velocities. The estimated values for R vary between 1,22 and 1,50, whereas the distribution coefficients were in the range of 0,1 to 0,05 L kg-1. It should be said that the breakthrough curves display hysteresis, leading to a desorption behavior that proceeds faster than the adsorption process.Puesto que tanto valores bajos como altos de F- en las aguas subterráneas tienen efectos adversos en la salud de los humanos (mayor cantidad de caries, y manchas del esmalte dental e incluso deformaciones óseas, respectivamente, han sido muchos los esfuerzos destinados a dilucidar el movimiento de especies fluoradas en ambientes acuosos. Ello es así porque el consumo de agua por parte de seres humanos representa la mayor fuente de ingreso de F-. Este trabajo presenta los resultados de siete experimentos dinámicos en los que soluciones de diferentes [F

  2. The effects of surfactants and solution chemistry on the transport of multiwalled carbon nanotubes in quartz sand-packed columns.

    Science.gov (United States)

    Lu, Yinying; Xu, Xiaopan; Yang, Kun; Lin, Daohui

    2013-11-01

    The effect of different surfactants on the transport of multiwalled carbon nanotubes (MWCNTs) in quartz sand-packed columns was firstly investigated under various conditions. The stable plateau values (C(max)) of the breakthrough curves (BTCs), critical PVs (the number of pore volumes of infusions needed to reach the C(max)), maximum transport distances (L(max)), deposition rate coefficients (kd) and retention rates were calculated to compare the transport and retention of MWCNTs under various conditions. Stability of the MWCNT suspensions as a function of the influencing factors was examined to reveal the underlying mechanism of the MWCNT retention. Results showed that MWCNTs suspended by different surfactants presented different BTCs; the MWCNT transport increased with increasing sand size and MWCNT concentration; high flow velocity was favorable for the MWCNT transport, while high Ca(2+) concentration and low pH were unfavorable for the transport; hetero-aggregation, straining and site blocking occurred during the transport. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Mobility of icy sand packs, with application to Martian permafrost

    Science.gov (United States)

    Durham, W.B.; Pathare, A.V.; Stern, L.A.; Lenferink, H.J.

    2009-01-01

    [1] The physical state of water on Mars has fundamental ramifications for both climatology and astrobiology. The widespread presence of "softened" Martian landforms (such as impact craters) can be attributed to viscous creep of subsurface ground ice. We present laboratory experiments designed to determine the minimum amount of ice necessary to mobilize topography within Martian permafrost. Our results show that the jammed-to-mobile transition of icy sand packs neither occurs at fixed ice content nor is dependent on temperature or stress, but instead correlates strongly with the maximum dry packing density of the sand component. Viscosity also changes rapidly near the mobility transition. The results suggest a potentially lower minimum volatile inventory for the impact-pulverized megaregolith of Mars. Furthermore, the long-term preservation of partially relaxed craters implies that the ice content of Martian permafrost has remained close to that at the mobility transition throughout Martian history. Copyright 2009 by the American Geophysical Union.

  4. Horizontal ethanol floods in clean, uniform, and layered sand packs under confined conditions

    National Research Council Canada - National Science Library

    Grubb, Dennis G; Sitar, Nicholas

    1999-01-01

    Six ethanol floods were conducted in clean, uniform, and layered crystal silica sands to establish a baseline performance and sweep efficiency of ethanol flooding in clean sand packs under confined conditions...

  5. Modeling flow through the sand pack: implications for groundwater sampling from multi- level monitoring wells in fractured bedrock aquifers.

    Science.gov (United States)

    Kozuskanich, J.; Novakowski, K.; Anderson, B.

    2009-05-01

    Multi-level piezometers are often used in groundwater studies to monitor multiple zones within a single borehole. In the fractured rock setting the monitoring intervals are typically designed to isolate discrete fracture features (single fractures or fracture zones). This can be very useful for determining vertical connectivity and the distribution of a contaminant within a fractured rock aquifer. A simple and inexpensive method for completing a bedrock borehole as a multi-level piezometer is to use PVC screen and riser, a sand pack around the screened section, and bentonite to isolate each interval. Flow into the borehole is dominantly confined to the intersecting discrete fracture features. The objective of this study is to examine the nature of the flow through the sand pack and screen slots as water travels from the fracture to the pump intake under pumping conditions. Our conceptual model suggests only a portion of the sand pack in the vicinity of the fractures should be hydraulically active in this scenario. Thus, portions of the wellbore may remain stagnant during pumping depending on the location of the pump intake with respect to the fractures. Flow paths in the sand pack may be controlled by the relationship between the transmissivity of the fracture and screen slots. HydroGeoSphere, a numerical model for flow and solute transport in discrete fractures and porous media, will be used to validate the conceptual model and define the head and velocity profiles in a multi-level interval under various pumping rate and discrete fracture aperture scenarios. The results of this study could have implications for defining a "well volume" in sampling protocols designed for multi-level piezometers in bedrock aquifer systems. The results may also be a useful tool for interpreting the significance of the sand pack as a source of bacteria in water quality monitoring studies that use multi-level piezometer construction of this sort.

  6. Pilot scale benzene stripping column testing: Review of test data and application to the ITP columns

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Gaughan, T.P.; Taylor, G.A.

    1993-09-10

    Radioactive cesium will be removed from aqueous high level waste (HLW) solutions by precipitation with sodium tetraphenyl borate (TPB) in the In-Tank Precipitation (ITP) process. Benzene is generated due to the radiolysis of TPB, and dissolves into the decontaminated salt solution (DSS) and into the water used to wash (WW) the precipitate. These solutions will be processed through stripping columns to reduce the benzene concentration to satisfy limits for disposal of the DSS and for temporary storage of the WW. A pilot scale testing program to evaluate the stripping column operation in support of ITP startup activities has been completed. Equipment and test plans were developed so that data obtained from the pilot scale testing would be directly applicable to full scale column operation and could be used to project hydraulic performance and stripping efficiency of both columns. A review of the test data indicate that the ITP stripping columns will be capable of reducing benzene concentrations in salt solutions to satisfy Saltstone and Tank 22 acceptance limits. An antifoam (AF) will be required to maintain the column differential pressure below the vendor recommendation of 40 inches wc so that design feed rates can be achieved. Additionally, the testing program indicated that the nitrogen rate can be decreased from the ITP column design rates and still satisfy benzene concentration requirements in the product.

  7. A column leaching test for inorganic contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Hopp, L.; Buczko, U. [Dept. of Hydrology, Univ. of Bayreuth, Bayreuth (Germany); Durner, W. [Inst. of Geoecology, Technical Univ. of Braunschweig, Braunschweig (Germany); Peiffer, S. [Dept. of Hydrogeology, RWTH Aachen, Aachen (Germany)

    2002-07-01

    The knowledge of soluble and mobilisable substances in the deep percolating water is the basis for the assessment of the risk of groundwater contamination by a contaminated soil. In accordance with the current version of the German Soil Protection Regulation (July 1999, Paragraph 2) this evaluation is specified as an estimation of pollutant entries that derive from contaminated sites. It consists therefore of an emission estimation and a transport prognosis through the vadose zone. All investigation procedures used so far for judging contaminated sites consider neither the influence of the heterogeneous structure of the flow zone in the soil which can lead to preferential flow nor the effect of speciation on mobility of heavy metals. In addition to that, most leaching tests are carried out under conditions which correspond little to the local natural conditions in the field (e.g. water/solid phase relation or chemical environment). (orig.)

  8. Tube and column agglutination technology for autocontrol testing.

    Science.gov (United States)

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  9. Engineered Barrier Systems Thermal-Hydraulic-Chemical Column Test Report

    Energy Technology Data Exchange (ETDEWEB)

    W.E. Lowry

    2001-12-13

    The Engineered Barrier System (EBS) Thermal-Hydraulic-Chemical (THC) Column Tests provide data needed for model validation. The EBS Degradation, Flow, and Transport Process Modeling Report (PMR) will be based on supporting models for in-drift THC coupled processes, and the in-drift physical and chemical environment. These models describe the complex chemical interaction of EBS materials, including granular materials, with the thermal and hydrologic conditions that will be present in the repository emplacement drifts. Of particular interest are the coupled processes that result in mineral and salt dissolution/precipitation in the EBS environment. Test data are needed for thermal, hydrologic, and geochemical model validation and to support selection of introduced materials (CRWMS M&O 1999c). These column tests evaluated granular crushed tuff as potential invert ballast or backfill material, under accelerated thermal and hydrologic environments. The objectives of the THC column testing are to: (1) Characterize THC coupled processes that could affect performance of EBS components, particularly the magnitude of permeability reduction (increases or decreases), the nature of minerals produced, and chemical fractionation (i.e., concentrative separation of salts and minerals due to boiling-point elevation). (2) Generate data for validating THC predictive models that will support the EBS Degradation, Flow, and Transport PMR, Rev. 01.

  10. In-plant testing of microbubble column flotation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, R.H.; Luttrell, G.H.; Adel, G.T.; Mankosa, M.J.

    1991-07-31

    Microbubble column flotation (MCF) was developed at the Virginia Center for Coal and Minerals Processing (VCCMP) for the selective recovery of fine particles. Bench-scale test work conducted at VCCMP, largely under the sponsorship of the U.S. Department of Energy (DOE), showed that the technology worked well for both coal and mineral applications. For the technology to be commercially successful, however, a full-scale demonstration of the MCF technology was deemed necessary. This report summarizes the results of work performed under the DOE project entitled In-plant Testing of Microbubble Column Flotation.'' The objectives of this research and development effort were to duplicate the bench-scale performance of the MCF process in a full-scale unit, to verify the scale-up procedure developed in an earlier project, and to demonstrate the applicability of the MCF technology to the coal industry.

  11. In-plant testing of microbubble column flotation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, R.H.; Luttrell, G.H.; Adel, G.T.; Mankosa, M.J.

    1991-07-31

    Microbubble column flotation (MCF) was developed at the Virginia Center for Coal and Minerals Processing (VCCMP) for the selective recovery of fine particles. Bench-scale test work conducted at VCCMP, largely under the sponsorship of the U.S. Department of Energy (DOE), showed that the technology worked well for both coal and mineral applications. For the technology to be commercially successful, however, a full-scale demonstration of the MCF technology was deemed necessary. This report summarizes the results of work performed under the DOE project entitled ``In-plant Testing of Microbubble Column Flotation.`` The objectives of this research and development effort were to duplicate the bench-scale performance of the MCF process in a full-scale unit, to verify the scale-up procedure developed in an earlier project, and to demonstrate the applicability of the MCF technology to the coal industry.

  12. Identification of a Binary Distillation Column Using Pulse Testing

    OpenAIRE

    KIRBAŞLAR, Ş. İsmail; AYDIN, Ahmet; DRAMUR, Umur

    1998-01-01

    The binary system of methanol-tert-buthanol was studied at atmospheric pressure in a 53-tray, 35 mm inside diameter sieve tray distillation column. The column had a vertical thermosiphon reboiler and an overhead condenser. During the continuous distillation, the effect of the reflux flow rate and vapour flow rate to the column as rectangular pulse input variables were investigated in the frequency domain. The experimental rectangular pulse input x(t) and output y(t) of the column we...

  13. Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hamm, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Smith, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Morse, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2013-12-20

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life of 99Tc, effective management of 99Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99Tc during the vitrification process. Removal of 99Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99Tc is predominantly found in the tank supernate as pertechnetate (TcO4-). Perrhenate (ReO4-) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of

  14. Mitigation of Oil in Water Column: Mitigation Prototype Tests

    Science.gov (United States)

    2017-06-01

    technologies or techniques that can mitigate the impacts of oil in the water column on the surrounding environment through containment, diversion, or...impacts on the environment , water intakes, and commercial facilities. Currently there is no well-established technology , technique, or strategy to prevent... technology did not prove to be effective at removing the dispensed oil. 3. Minimization of environmental impacts with a focus on wildlife and plant life

  15. Engineering the bundled glass column: From the design concept to full-scale experimental testing

    NARCIS (Netherlands)

    Oikonomopoulou, F.; Bristogianni, T.; Veer, F.A.; Nijsse, R.

    This article gives an overview of the research conducted by the authors from the design concept to the engineering and full-scale testing of the bundled glass column. Consisting of adhesively bonded solid glass rods, the bundled column is a promising solution for transparent compressive members. To

  16. Multi-Column Experimental Test Bed for Xe/Kr Separation

    Energy Technology Data Exchange (ETDEWEB)

    Greenhalgh, Mitchell Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Garn, Troy Gerry [Idaho National Lab. (INL), Idaho Falls, ID (United States); Welty, Amy Keil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lyon, Kevin Lawrence [Idaho National Lab. (INL), Idaho Falls, ID (United States); Watson, Tony Leroy [Idaho National Lab. (INL), Idaho Falls, ID (United States)ry

    2015-08-31

    Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both

  17. Performance tests on column materials for {sup 99}Mo-{sup 99m}Tc generator

    Energy Technology Data Exchange (ETDEWEB)

    Sombrito, E.Z.; Bulos, A.D.; Tangonan, M.C. [Chemistry Research Section, Atomic Research Div., Philippine Nuclear Research Inst., Quezon (Philippines)

    1998-10-01

    To meet the need of producing a {sup 99}Mo-{sup 99m}Tc generator, based on low specific activity reactor-produced {sup 99}Mo, different procedures for preparing zirconium molybdate gels were tested. Performance tests were done on molybdate gel columns prepared using the procedures developed by Vietnam and China, and recently, on a polyzirconium compound (PZC) prepared in Japan. The conditions for the batch drying of a large volume of the gel material were studied as well as the conditions in preparing a column to concentrate technetium-99m. The performance of PZC sample as column material for the generator was also evaluated. (author)

  18. Core-shell column Tanaka characterization and additional tests using active pharmaceutical ingredients.

    Science.gov (United States)

    Ludvigsson, Jufang Wu; Karlsson, Anders; Kjellberg, Viktor

    2016-12-01

    In the last decade, core-shell particles have gained more and more attention in fast liquid chromatography separations due to their comparable performance with fully porous sub-2 μm particles and their significantly lower back pressure. Core-shell particles are made of a solid core surrounded by a shell of classic fully porous material. To embrace the developed core-shell column market and use these columns in pharmaceutical analytical applications, 17 core-shell C18 columns purchased from various vendors with various dimensions (50 mm × 2.1 mm to 100 mm × 3 mm) and particle sizes (1.6-2.7 μm) were characterized using Tanaka test protocols. Furthermore, four selected active pharmaceutical ingredients were chosen as test probes to investigate the batch to batch reproducibility for core-shell columns of particle size 2.6-2.7 μm, with dimension of 100 × 3 mm and columns of particle size 1.6 μm, with dimension 100 × 2.1 mm under isocratic elution. Columns of particle size 2.6-2.7 μm were also tested under gradient elution conditions. To confirm the claimed comparable efficiency of 2.6 μm core-shell particles as sub-2 μm fully porous particles, column performances of the selected core-shell columns were compared with BEH C18 , 1.7 μm, a fully porous column material as well. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Multi-Column Experimental Test Bed Using CaSDB MOF for Xe/Kr Separation

    Energy Technology Data Exchange (ETDEWEB)

    Welty, Amy Keil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Greenhalgh, Mitchell Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Garn, Troy Gerry [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    Processing of spent nuclear fuel produces off-gas from which several volatile radioactive components must be separated for further treatment or storage. As part of the Off-gas Sigma Team, parallel research at INL and PNNL has produced several promising sorbents for the selective capture of xenon and krypton from these off-gas streams. In order to design full-scale treatment systems, sorbents that are promising on a laboratory scale must be proven under process conditions to be considered for pilot and then full-scale use. To that end, a bench-scale multi-column system with capability to test multiple sorbents was designed and constructed at INL. This report details bench-scale testing of CaSDB MOF, produced at PNNL, and compares the results to those reported last year using INL engineered sorbents. Two multi-column tests were performed with the CaSDB MOF installed in the first column, followed with HZ-PAN installed in the second column. The CaSDB MOF column was placed in a Stirling cryocooler while the cryostat was employed for the HZ-PAN column. Test temperatures of 253 K and 191 K were selected for the first column while the second column was held at 191 K for both tests. Calibrated volume sample bombs were utilized for gas stream analyses. At the conclusion of each test, samples were collected from each column and analyzed for gas composition. While CaSDB MOF does appear to have good capacity for Xe, the short time to initial breakthrough would make design of a continuous adsorption/desorption cycle difficult, requiring either very large columns or a large number of smaller columns. Because of the tenacity with which Xe and Kr adhere to the material once adsorbed, this CaSDB MOF may be more suitable for use as a long-term storage solution. Further testing is recommended to determine if CaSDB MOF is suitable for this purpose.

  20. The Inter Facility Testing of a Standard Oscillating Water Column (OWC) Type Wave Energy Converter (WEC)

    DEFF Research Database (Denmark)

    Andersen, Morten Thøtt; Thomsen, Jonas Bjerg

    This report describes the behavior and preliminary performance of a simplified standard oscillating water column (OWC) wave energy converter (WEC). The same tests will be conducted at different scales at 6 different test facilities and the results obtained will be used for comparison. This project...

  1. Application of column tests and electrical resistivity methods for leachate transport monitoring

    Directory of Open Access Journals (Sweden)

    Wychowaniak Dorota

    2015-09-01

    Full Text Available Development of the human civilization leads to the pollution of environment. One of the contamination which are a real threat to soil and groundwater are leachates from landfills. In this paper the solute transport through soil was considered. For this purpose, the laboratory column tests of chlorides tracer and leachates transport on two soil samples have been carried out. Furthermore, the electrical resistivity method was applied as auxiliary tool to follow the movements of solute through the soil column what allowed to compare between the results obtained with column test method and electrical resistivity measurements. Breakthrough curves obtained by conductivity and resistivity methods represents similar trends which leads to the conclusion about the suitability of electrical resistivity methods for contamination transport monitoring in soil-water systems.

  2. Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams

    Science.gov (United States)

    Dong, Hongying; Cao, Wanlin; Wu, Haipeng; Zhang, Jianwei; Xu, Fangfang

    2013-12-01

    A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements — the CFST columns and SP deep beams — to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.

  3. Application of column tests and electrical resistivity methods for leachate transport monitoring

    OpenAIRE

    Wychowaniak Dorota; Zawadzki Łukasz; Lech Mariusz

    2015-01-01

    Development of the human civilization leads to the pollution of environment. One of the contamination which are a real threat to soil and groundwater are leachates from landfills. In this paper the solute transport through soil was considered. For this purpose, the laboratory column tests of chlorides tracer and leachates transport on two soil samples have been carried out. Furthermore, the electrical resistivity method was applied as auxiliary tool to follow the movements of solute through t...

  4. Technetium removal column flow testing with alkaline, high salt, radioactive tank waste

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, D.L. Jr.; Kurath, D.E.; Golcar, G.R. [Pacific Northwest National Lab., Richland, WA (United States); Conradson, S.D. [Los Alamos National Lab., NM (United States)

    1996-09-30

    This report describes two bench-scale column tests conducted to demonstrate the removal of Tc-99 from actual alkaline high salt radioactive waste. The waste used as feed for these tests was obtained from the Hanford double shell tank AW-101, which contains double shell slurry feed (DSSF). The tank sample was diluted to approximately 5 M Na with water, and most of the Cs-137 was removed using crystalline silicotitanates. The tests were conducted with two small columns connected in series, containing, 10 mL of either a sorbent, ABEC 5000 (Eichrom Industries, Inc.), or an anion exchanger Reillex{trademark}-HPQ (Reilly Industries, Inc.). Both materials are selective for pertechnetate anion (TcO{sub 4}{sup -}). The process steps generally followed those expected in a full-scale process and included (1) resin conditioning, (2) loading, (3) caustic wash to remove residual feed and prevent the precipitation of Al(OH){sub 3}, and (4) elution. A small amount of Tc-99m tracer was added as ammonium pertechnetate to the feed and a portable GEA counter was used to closely monitor the process. Analyses of the Tc-99 in the waste was performed using ICP-MS with spot checks using radiochemical analysis. Technetium x-ray absorption spectroscopy (XAS) spectra of 6 samples were also collected to determine the prevalence of non-pertechnetate species [e.g. Tc(IV)].

  5. Cyclic Testing for Structural Detail Improvement of CFT Column-Foundation Connections

    Directory of Open Access Journals (Sweden)

    Hee-Ju Kim

    2015-04-01

    Full Text Available In this study, concrete-filled tube (CFT column-to-foundation connections were investigated experimentally to improve the design of their structural details. Initially, five different types of foundation connections, which were classified according to the design parameters incorporating the types of anchor bolts, shear connectors, base members, and reinforced bars used, were fabricated. After conducting structural experiments on these foundation models, the performance and capacity of the individual model cases from the test results were compared with each other. The test results showed that some of the test models designed according to current design guidelines had problems related to the structural details. Therefore, this study proposed an adequate design methodology to improve the performance of foundation components, such as high tension bolt, base frame members, and embedded plate. An analytical investigation of the force-deformation relationship as well as the characteristic strains distributed over the individual foundation components was performed.

  6. Application of column tests and electrical resistivity methods for leachate transport monitoring

    National Research Council Canada - National Science Library

    Dorota Wychowaniak; Łukasz Zawadzki; Mariusz Lech

    2015-01-01

    ... out. Furthermore, the electrical resistivity method was applied as auxiliary tool to follow the movements of solute through the soil column what allowed to compare between the results obtained with column...

  7. Evaluation of bioleaching column test of sulphide copper ore and copper concentrate using preconditioned surface

    Directory of Open Access Journals (Sweden)

    Videla Leiva Alvaro

    2016-01-01

    Full Text Available Bacterial activity can be related to the presence of Fe+3 in the solution, which drives copper oxidation during the secondary copper low grade sulfide ore leaching process. The present work evaluates improvements in kinetics of leaching when ferroxidans are preconditioned in an inert surface helping to build a biofilm which improves metabolism of the colony. The present work shows evaluation using laboratory columns to perform bioleaching during a 30 days period under three conditions: a base column with no inert surface, a column with loofa available for bacterial growth and conditioning, and finally a column with the loofa surface ground and distributed in the column among the particles.

  8. Construction and demolition waste: Comparison of standard up-flow column and down-flow lysimeter leaching tests

    DEFF Research Database (Denmark)

    Butera, Stefania; Hyks, Jiri; Christensen, Thomas Højlund

    2015-01-01

    , Sb, Se, Si, Zn. Observed differences between tests are likely to be due to differences in pH related to crushing and exposure of fresh particle surfaces, as well as in equilibrium conditions. In the case of C&DW, the standardised column tests, which are more practical, are considered to acceptably...... describe cumulative releases at L/S 10l·kg-1TS in percolation scenarios. However, when the focus is on estimation of initial concentrations for (for example) risk assessment, data from standardised column tests may not be fully applicable, and data from lysimeters may be used for validation purposes. Se...

  9. Development and testing of a rotary disc pulser for pulse column application

    Energy Technology Data Exchange (ETDEWEB)

    Olson, A.L.

    1988-10-01

    Air pulse column contactors are a favored method of conducting radiochemical liquid-liquid separations processes. They have no moving parts and are easily operated from behind thick shielding. A ruggedly constructed more reliable air pulsing device was developed and its operation mathematically characterized in this study. Additionally, a correlation for the column perforated nozzle plate discharge coefficient was developed. Rigorous mass, momentum, and energy balances were solved using a computer software code entitled ''Advanced Continuous Simulation Language.'' Experimental data from a 2-inch diameter glass column equipped with the prototypical air pulser showed that column pulse amplitudes could be predicted within 10% for the conditions studied and within 5% for normal column operating conditions. 17 refs., 45 figs., 15 tabs.

  10. Axial Compression Tests on Corroded Reinforced Concrete Columns Consolidated with Fibre Reinforced Polymers

    Directory of Open Access Journals (Sweden)

    Bin Ding

    2017-06-01

    Full Text Available Reinforced concrete structure featured by strong bearing capacity, high rigidity, good integrity, good fire resistance, and extensive applicability occupies a mainstream position in contemporary architecture. However, with the development of social economy, people need higher requirements on architectural structure; durability, especially, has been extensively researched. Because of the higher requirement on building material, ordinary reinforced concrete structure has not been able to satisfy the demand. As a result, some new materials and structures have emerged, for example, fibre reinforced polymers. Compared to steel reinforcement, fibre reinforced polymers have many advantages, such as high tensile strength, good durability, good shock absorption, low weight, and simple construction. The application of fibre reinforced polymers in architectural structure can effectively improve the durability of the concrete structure and lower the maintenance, reinforcement, and construction costs in severe environments. Based on the concepts of steel tube concrete, fibre reinforced composite material confined concrete, and fibre reinforced composite material tubed concrete, this study proposes a novel composite structure, i.e., fibre reinforced composite material and steel tube concrete composite structure. The structure was developed by pasting fibre around steel tube concrete and restraining core concrete using fibre reinforced composite material and steel tubes. The bearing capacity and ultimate deformation capacity of the structure was tested using column axial compression test.

  11. The fate of MtBE during Fenton-like treatments through laboratory scale column tests

    Science.gov (United States)

    Piscitelli, Daniela; Zingaretti, Daniela; Verginelli, Iason; Gavasci, Renato; Baciocchi, Renato

    2015-12-01

    In Situ Chemical Oxidation (ISCO) based on the Fenton's process is a proven technology for the treatment of groundwater contaminated by organic compounds. Nevertheless, the application of this treatment process to methyl tert-butyl ether (MtBE) is questioned, as there are concerns about its capacity to achieve complete mineralization. Many existing studies have focused on water contaminated by MtBE and are thus not representative of in situ treatments since they do not consider the presence of soil. In this work, the effectiveness of a Fenton-like process for MtBE treatment was proven in soil column tests performed at operating conditions (i.e., oxidant and contaminant concentration and flow rates) resembling those typically used for in situ applications. No MtBE by-products were detected in any of the tested conditions, thus suggesting that the tert-butyl group of MtBE was completely degraded. A mass balance based on the CO2 produced was used as evidence that most of the MtBE removed was actually mineralized. Finally, the obtained results show that preconditioning of soil with a chelating agent (EDTA) significantly enhanced MtBE oxidation.

  12. Migration of Chemotactic Bacteria Transverse to Flow in Response to a Benzoate Source Plume Created in a Saturated Sand-Packed Microcosm

    Science.gov (United States)

    Ford, R.; Boser, B.

    2012-12-01

    performed to explore the relationship between the exposure time of the bacteria to benzoate and the transverse migration of bacteria due to chemotaxis. Experimentally determined transport parameters were then used as input to a two-dimensional mathematical model for bacterial transport. Model results showed the shift in center of mass for chemotactic bacteria was greater for 2 cm and 3 cm spacing than for 4 cm spacing for a given chemotactic sensitivity coefficient value, which showed that an increase in the exposure time of the bacteria to the model contaminant benzoate increased the transverse migration of bacteria. Modeling was used to test the effects of changing the chemotactic sensitivity coefficient and the chemotaxis receptor constant at three different bacteria and benzoate separation distances: 2 cm, 3 cm, and 4 cm. Mathematical models from this work can be applied to future field-scale studies to select design parameters that maximize transverse migration of chemotactic bacteria.

  13. Characterization and quality control of stone columns using surface wave testing

    National Research Council Canada - National Science Library

    Madun, A; Jefferson, I; Foo, K.Y; Chapman, D.N; Culshaw, M.G; Atkins, P.R

    2012-01-01

    .... This study evaluates the application of surface waves in characterizing the properties of laterally heterogeneous soil, specifically for use in the quality control of stone columns used for ground improvement...

  14. Developing and Validating a Rapid Small-Scale Column Test Procedure for GAC Selection using Reconstituted Lyophilized NOM

    Science.gov (United States)

    Cost effective design and operation of Granular Activated Carbon (GAC) facilities requires the selection of GAC that is optimal for a specific site. Rapid small-scale column tests (RSSCTs) are widely used for GAC assessment due to several advantages, including the ability to simu...

  15. PILOT SCALE TESTING OF MONOSODIUM TITANATE MIXING FOR THE SRS SMALL COLUMN ION EXCHANGE PROCESS - 11224

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M.; Restivo, M.; Williams, M.; Herman, D.; Steeper, T.

    2011-01-25

    The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and select actinides from Savannah River Site (SRS) Liquid Waste using an existing waste tank (i.e., Tank 41H) to house the process. Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for suspending monosodium titanate (MST), crystalline silicotitanate (CST), and simulated sludge. The purpose of this pilot scale testing is to determine the requirements for the pumps to suspend the MST particles so that they can contact the strontium and actinides in the liquid and be removed from the tank. The pilot-scale tank is a 1/10.85 linear scaled model of SRS Tank 41H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 41H. The pump locations correspond to the proposed locations in Tank 41H by the SCIX program (Risers B5 and B2 for two pump configurations and Risers B5, B3, and B1 for three pump configurations). The conclusions from this work follow: (i) Neither two standard slurry pumps nor two quad volute slurry pumps will provide sufficient power to initially suspend MST in an SRS waste tank. (ii) Two Submersible Mixer Pumps (SMPs) will provide sufficient power to initially suspend MST in an SRS waste tank. However, the testing shows the required pump discharge velocity is close to the maximum discharge velocity of the pump (within 12%). (iii) Three SMPs will provide sufficient power to initially suspend MST in an SRS waste tank. The testing shows the required pump discharge velocity is 66% of the maximum discharge velocity of the pump. (iv) Three SMPs are needed to resuspend MST that has settled in a waste tank at nominal 45 C for four weeks. The testing shows the required pump discharge velocity is 77% of the maximum discharge velocity of the pump. Two SMPs are not sufficient to resuspend MST that settled under these

  16. Construction and demolition waste: Comparison of standard up-flow column and down-flow lysimeter leaching tests.

    Science.gov (United States)

    Butera, Stefania; Hyks, Jiri; Christensen, Thomas H; Astrup, Thomas F

    2015-09-01

    Five samples of construction and demolition waste (C&DW) were investigated in order to quantify leaching of inorganic elements under percolation conditions according to two different experimental setups: standardised up-flow saturated columns (<4mm particle size) and unsaturated, intermittent down-flow lysimeters (<40mm particle size). While standardised column tests are meant primarily to provide basic information on characteristic leaching properties and mechanisms and not to reproduce field conditions, the lysimeters were intended to mimic the actual leaching conditions when C&DW is used in unbound geotechnical layers. In practice, results from standardised percolation tests are often interpreted as estimations of actual release from solid materials in percolation scenarios. In general, the two tests yielded fairly similar results in terms of cumulative release at liquid-to-solid ratio (L/S) 10l·kgTS; however, significant differences were observed for P, Pb, Ba, Mg and Zn. Further differences emerged in terms of concentration in the early eluates (L/S<5l·kg(-1)TS) for Al, As, Ba, Cd, Cu, DOC, Mg, Mn, Ni, P, Pb, Sb, Se, Si, Zn. Observed differences between tests are likely to be due to differences in pH related to crushing and exposure of fresh particle surfaces, as well as in equilibrium conditions. In the case of C&DW, the standardised column tests, which are more practical, are considered to acceptably describe cumulative releases at L/S 10l·kg(-1)TS in percolation scenarios. However, when the focus is on estimation of initial concentrations for (for example) risk assessment, data from standardised column tests may not be fully applicable, and data from lysimeters may be used for validation purposes. Se, Cr and, to a lesser extent, SO4 and Sb were leaching from C&DW in critical amounts compared with existing limit values. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Assessment the Strength of Column and Beam at Religious Building Structure by Using Non-Destructive Test

    Directory of Open Access Journals (Sweden)

    Adnan Nor Azizah

    2017-01-01

    Full Text Available The mosque is a sacred place for worship for Muslims. To this date, the traditional mosque needs to be conserved and preserved wood for aesthetic value. Nowadays, most of the mosque materials have a combination of other materials such as concrete, wood and glass. In order to maintain its fit-for-purpose status, non-destructive tests (NDTs are recommended to be done periodically to identify hidden deteriorations for planning maintenance and repair works without damaging the structure itself. This paper presents two NDTs - Ultrasonic Pulse Velocity tool (PUNDIT and Schmidt rebound hammer test – done on 38 concrete columns and 29 ground beams of Masjid Kampung Ulu Semerah, Batu Pahat. Recorded readings have shown that most beams and columns had moderate or weak strength. As such, remedial action should be taken to uphold the mosque’s structural integrity.

  18. Testing cloud-radiation algorithms in GCMs and single-column models

    Energy Technology Data Exchange (ETDEWEB)

    Somerville, R. [Univ. of California, La Jolla, CA (United States)

    1995-09-01

    Our poor understanding of cloud processes limits our ability to make realistic climate change predictions. Part of the problem is that we have too many cloud parameterizations and too few observations. Lack of contact between observationalists and modelers exacerbates this problem. The principle behind the single column model presented here is that the horizontal convergence of heat, momentum, and moisture is specified from observations. 2 refs., 2 figs.

  19. Subsurface arsenic removal column tests: from the laboratory to the field

    OpenAIRE

    Moed, D.H.; D. van Halem; Verberk, J.Q.J.C.; Paassen, J. A. M.; L. C. Rietveld

    2012-01-01

    Previous laboratory column experiments have given evidence of competitive effects between different groundwater constituents in the process of subsurface arsenic removal, a process in which arsenic is removed from groundwater by injecting water with oxygen into the subsurface. The presence of phosphate and other anions significantly limited arsenic removal. To investigate the influence of phosphate in natural groundwater, pumping stations in Loosdrecht (the Netherlands) and Subotica (Serbia) ...

  20. Slender CRC Columns

    DEFF Research Database (Denmark)

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    CRC is a high-performance steel fibre reinforced concrete with a typical compressive strength of 150 MPa. Design methods for a number of structural elements have been developed since CRC was invented in 1986, but the current project set out to further investigate the range of columns for which...... current design guides can be used. The columns tested had a slenderness varying from 1.11 to 12.76 and a reinforcement ratio (area of rebar to area of concrete) ranging from 0 to 8.8 %. A total of 77 tests were carried out - 61 columns were tested in ambient conditions and 16 columns were tested...

  1. Resonant column and torsional shear tests for the evaluation of the shear modulus and damping ratio of soil

    Science.gov (United States)

    Lentini, Valentina; Castelli, Francesco

    2017-11-01

    The paper reports the results of the dynamic characterization of an industrial area of the municipality of Enna, where the Laboratory of Earthquake Engineering and Dynamic Analysis has been realized. A Resonant Column/Torsional Cyclic Shear apparatus to perform laboratory tests on soil samples retrieved from the site, has allowed to obtain the values of shear modulus G and damping ratio D as a function of the shear strain level γ. The experimental results are in good agreement with the well-known curves relating to soil with similar characteristics.

  2. Evaluation of FRP Confinement Models for Substandard Rectangular RC Columns Based on Full-Scale Reversed Cyclic Lateral Loading Tests in Strong and Weak Directions

    Directory of Open Access Journals (Sweden)

    Hamid Farrokh Ghatte

    2016-09-01

    Full Text Available Although many theoretical and experimental studies are available on external confinement of columns using fiber-reinforced polymer (FRP jackets, as well as numerous models proposed for the axial stress-axial strain relation of concrete confined with FRP jackets, they have not been validated with a sufficient amount and variety of experimental data obtained through full-scale tests of reinforced concrete (RC columns with different geometrical and mechanical characteristics. Particularly, no systematical experimental data have been presented on full-scale rectangular substandard RC columns subjected to reversed cyclic lateral loads along either their strong or weak axes. In this study, firstly, test results of five full-scale rectangular substandard RC columns with a cross-sectional aspect ratio of two (300 mm × 600 mm are briefly summarized. The columns were tested under constant axial load and reversed cyclic lateral loads along their strong or weak axes before and after retrofitting with external FRP jackets. In the second stage, inelastic lateral force-displacement relationships of the columns are obtained analytically, making use of the plastic hinge assumption and different FRP confinement models available in the literature. Finally, the analytical findings are compared with the test results for both strong and weak directions of the columns. Comparisons showed that use of different models for the stress-strain relationship of FRP-confined concrete can yield significantly non-conservative or too conservative retrofit designs, particularly in terms of deformation capacity.

  3. Ranking nano-enabled hybrid media for simultaneous removal of contaminants with different chemistries: Pseudo-equilibrium sorption tests versus column tests.

    Science.gov (United States)

    Custodio, Tomas; Garcia, Jose; Markovski, Jasmina; McKay Gifford, James; Hristovski, Kiril D; Olson, Larry W

    2017-12-15

    The underlying hypothesis of this study was that pseudo-equilibrium and column testing conditions would provide the same sorbent ranking trends although the values of sorbents' performance descriptors (e.g. sorption capacity) may vary because of different kinetics and competition effects induced by the two testing approaches. To address this hypothesis, nano-enabled hybrid media were fabricated and its removal performances were assessed for two model contaminants under multi-point batch pseudo-equilibrium and continuous-flow conditions. Calculation of simultaneous removal capacity indices (SRC) demonstrated that the more resource demanding continuous-flow tests are able to generate the same performance rankings as the ones obtained by conducing the simpler pseudo-equilibrium tests. Furthermore, continuous overlap between the 98% confidence boundaries for each SRC index trend, not only validated the hypothesis that both testing conditions provide the same ranking trends, but also pointed that SRC indices are statistically the same for each media, regardless of employed method. In scenarios where rapid screening of new media is required to obtain the best performing synthesis formulation, use of pseudo-equilibrium tests proved to be reliable. Considering that kinetics induced effects on sorption capacity must not be neglected, more resource demanding column test could be conducted only with the top performing media that exhibit the highest sorption capacity. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Environmental Characterization of Mine Countermeasure Test Ranges: Hydrography and Water Column Optics

    Science.gov (United States)

    2015-09-30

    looking ADCP and near-bottom CTD/optics moorings along a transect within the test range, 2) ship based underway surface measurements of physical...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Upward looking ADCP and near-bottom CTD/optics moorings We deployed two RD Instruments...measurements were obtained: 13 days of bottom mounted ADCP /CTD/optics records at ten minute intervals (two sites) 41 ac9/CTD profiles at main

  5. Creative columns

    National Research Council Canada - National Science Library

    Hoff, Diane

    2017-01-01

      Here, Hoff presents creative columns. As her seventh-graders began learning about ancient Greece in social studies, in art they observed ancient Greek architecture, paying attention to the orders of Pork, Ionic, and Corinthian...

  6. Anthropogenic fibres in the Baltic Sea water column: Field data, laboratory and numerical testing of their motion.

    Science.gov (United States)

    Bagaev, A; Mizyuk, A; Khatmullina, L; Isachenko, I; Chubarenko, I

    2017-12-01

    Distribution of microplastics particles (MPs) in the water column is investigated on the base of 95 water samples collected from various depths in the Baltic Sea Proper in 2015-2016. Fibres are the prevalent type of MPs: 7% of the samples contained small films; about 40% had (presumably) paint flakes, while 63% contained coloured fibres in concentrations from 0.07 to 2.6 items per litre. Near-surface and near-bottom layers (defined as one tenth of the local depth) have 3-5 times larger fibre concentrations than intermediate layers. Laboratory tests demonstrated that sinking behaviour of a small and flexible fibre can be complicated, with 4-fold difference in sinking velocity for various random fibres' curvature during its free fall. Numerical tests on transport of fibres in the Baltic Sea Proper were performed using HIROMB reanalysis data (2007) for the horizontal velocity field and laboratory order-of-magnitude estimates for the sinking velocity of fibres. The model takes into account (i) motion of fibres together with currents, (ii) their very slow sinking, and (iii) their low re-suspension threshold. Sensitivity of the final distribution of fibres to variations of those parameters is examined. These experiments are the first step towards modelling of transport of fibres in marine environment and they seem to reproduce the main features of fibres distribution quite well. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Column test-based optimization of the permeable reactive barrier (PRB) technique for remediating groundwater contaminated by landfill leachates

    Science.gov (United States)

    Zhou, Dan; Li, Yan; Zhang, Yinbo; Zhang, Chang; Li, Xiongfei; Chen, Zhiliang; Huang, Junyi; Li, Xia; Flores, Giancarlo; Kamon, Masashi

    2014-11-01

    We investigated the optimum composition of permeable reactive barrier (PRB) materials for remediating groundwater heavily contaminated by landfill leachate, in column tests using various mixtures of zero-valent iron (ZVI), zeolite (Zeo) and activated carbon (AC) with 0.01-0.25, 3.0-5.0 and 0.7-1.0 mm grain sizes, respectively. The main contributors to the removal of organic/inorganic contaminants were ZVI and AC, and the optimum weight ratio of the three PRB materials for removing the contaminants and maintaining adequate hydraulic conductivity was found to be 5:1:4. Average reductions in chemical oxygen demand (COD) and contents of total nitrogen (TN), ammonium, Ni, Pb and 16 polycyclic aromatic hydrocarbons (PAHs) from test samples using this mixture were 55.8%, 70.8%, 89.2%, 70.7%, 92.7% and 94.2%, respectively. We also developed a systematic method for estimating the minimum required thickness and longevity of the PRB materials. A ≥ 309.6 cm layer with the optimum composition is needed for satisfactory longevity, defined here as meeting the Grade III criteria (the Chinese National Bureau of Standards: GB/T14848/93) for in situ treatment of the sampled groundwater for ≥ 10 years.

  8. Comparing the effectiveness of chronic water column tests with the crustaceans Hyalella azteca (order: Amphipoda) and Ceriodaphnia dubia (order: Cladocera) in detecting toxicity of current-use insecticides.

    Science.gov (United States)

    Deanovic, Linda A; Markiewicz, Dan; Stillway, Marie; Fong, Stephanie; Werner, Inge

    2013-03-01

    Standard U.S. Environmental Protection Agency laboratory tests are used to monitor water column toxicity in U.S. surface waters. The water flea Ceriodaphnia dubia is among the most sensitive test species for detecting insecticide toxicity in freshwater environments.Its usefulness is limited, however, when water conductivity exceeds 2,000 µS/cm (approximately 1 ppt salinity) and test effectiveness is insufficient. Water column toxicity tests using the euryhaline amphipod Hyalella azteca could complement C. dubia tests; however, standard chronic protocols do not exist. The present study compares the effectiveness of two water column toxicity tests in detecting the toxicity of two organophosphate (OP) and two pyrethroid insecticides: the short-term chronic C. dubia test, which measures mortality and fecundity, and a 10-d H. azteca test, which measures mortality and growth. Sensitivity was evaluated by comparing effect data, and end point variability was evaluated by comparing minimum significant differences. Tests were performed in synthetic water and filtered ambient water to quantify the influence of water matrix on effect concentrations. The H. azteca test detected pyrethroid toxicity far more effectively, while the C. dubia test was more sensitive to OPs. Among endpoints, H. azteca mortality was most robust. The results demonstrate that the H. azteca test is preferable when conductivity of water samples is 2,000 to 10,000 µS/cm or if contaminants of concern include pyrethroid insecticides. Copyright © 2012 SETAC.

  9. COLUMN TESSELLATIONS

    Directory of Open Access Journals (Sweden)

    Linh Ngoc Nguyen

    2015-06-01

    Full Text Available A new class of non facet-to-facet random tessellations in three-dimensional space is introduced -- the so-called column tessellations. The spatial construction is based on a stationary planar tessellation; each cell of the spatial tessellation is a prism whose base facet is  congruent to a cell of the planar tessellation. Thus intensities, topological and metric mean values of the spatial tessellation can be calculated from suitably chosen parameters of the planar tessellation.

  10. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.

    Science.gov (United States)

    Schweiger, Susanne; Hinterberger, Stephan; Jungbauer, Alois

    2017-12-08

    In the biopharmaceutical industry, pre-packed columns are the standard for process development, but they must be qualified before use in experimental studies to confirm the required performance of the packed bed. Column qualification is commonly done by pulse response experiments and depends highly on the experimental testing conditions. Additionally, the peak analysis method, the variation in the 3D packing structure of the bed, and the measurement precision of the workstation influence the outcome of qualification runs. While a full body of literature on these factors is available for HPLC columns, no comparable studies exist for preparative columns for protein chromatography. We quantified the influence of these parameters for commercially available pre-packed and self-packed columns of disposable and non-disposable design. Pulse response experiments were performed on 105 preparative chromatography columns with volumes of 0.2-20ml. The analyte acetone was studied at six different superficial velocities (30, 60, 100, 150, 250 and 500cm/h). The column-to-column packing variation between disposable pre-packed columns of different diameter-length combinations varied by 10-15%, which was acceptable for the intended use. The column-to-column variation cannot be explained by the packing density, but is interpreted as a difference in particle arrangement in the column. Since it was possible to determine differences in the column-to-column performance, we concluded that the columns were well-packed. The measurement precision of the chromatography workstation was independent of the column volume and was in a range of±0.01ml for the first peak moment and±0.007 ml 2 for the second moment. The measurement precision must be considered for small columns in the range of 2ml or less. The efficiency of disposable pre-packed columns was equal or better than that of self-packed columns. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  11. Small Column Ion Exchange Testing of Superlig 644 for Removal of 137Cs from Hanford Tank Waste Envelope A (Tank 241-AW-101)

    Energy Technology Data Exchange (ETDEWEB)

    DE Kurath; DL Blanchard; JR Bontha

    2000-07-12

    The current BNFL Inc. flow sheet for the pretreatment of the Hanford High-Level tank wastes includes the use of Superlig{reg_sign} materials for the removal of {sup 137}Cs from the aqueous fraction of the waste. The Superlig materials applicable to cesium removal include the cesium selective Superlig 632 and Superlig 644. These materials have been developed and supplied by IBC Advanced Technologies, Inc., American Fork, UT. The work contained in this report involves testing the Superlig 644 ion exchange material in a small dual column system (15 mL each; L/D = 5.7). The sample processed was approximately 2.5 L of diluted waste [Na{sup +}] = 4.6M from Tank 241-AW-101 (Envelope A). This waste had been previously clarified in a single tube cross-flow filtration unit. All ion exchange process steps were tested including resin bed preparation, loading, feed displacement water rinse, elution and resin regeneration. During the initial run, the lag column did not perform as expected so that the {sup 137}Cs concentration in the effluent composite was above the LAW treatment limits. This required a second column run with the partially decontaminated feed that was conducted at a higher flow rate. A summary of performance measures for both runs is shown in Table S1. The Cs {lambda} values represent a measure of the effective capacity of the SL-644 resin. The Cs {lambda} of 143 for the lead column in run 1 is very similar to the value obtained by the Savannah River Technology Center during Phase 1A testing. The larger Cs {lambda} value for run 2 reflects a general trend for the effective capacity of the SL-644 material to increase as the cesium concentration decreases. The low value for the lag column during the first run indicates that it did not perform as expected. This may have been due to insufficient conditioning of the bed prior to the start of the loading step or to air in the bed that caused channeling. Equilibrium data obtained with batch contacts using the AW-101 Cs

  12. Investigations on mobility of carbon colloid supported nanoscale zero-valent iron (nZVI) in a column experiment and a laboratory 2D-aquifer test system.

    Science.gov (United States)

    Busch, Jan; Meißner, Tobias; Potthoff, Annegret; Oswald, Sascha E

    2014-09-01

    Nanoscale zero-valent iron (nZVI) has recently gained great interest in the scientific community as in situ reagent for installation of permeable reactive barriers in aquifer systems, since nZVI is highly reactive with chlorinated compounds and may render them to harmless substances. However, nZVI has a high tendency to agglomerate and sediment; therefore it shows very limited transport ranges. One new approach to overcome the limited transport of nZVI in porous media is using a suited carrier colloid. In this study we tested mobility of a carbon colloid supported nZVI particle "Carbo-Iron Colloids" (CIC) with a mean size of 0.63 μm in a column experiment of 40 cm length and an experiment in a two-dimensional (2D) aquifer test system with dimensions of 110 × 40 × 5 cm. Results show a breakthrough maximum of 82 % of the input concentration in the column experiment and 58 % in the 2D-aquifer test system. Detected residuals in porous media suggest a strong particle deposition in the first centimeters and few depositions in the porous media in the further travel path. Overall, this suggests a high mobility in porous media which might be a significant enhancement compared to bare or polyanionic stabilized nZVI.

  13. Integrated AMP-PAN, TRUEX, and SREX Flowsheet Test to Remove Cesium, Surrogate Actinide Elements, and Strontium from INEEL Tank Waste Using Sorbent Columns and Centrifugal Contactors

    Energy Technology Data Exchange (ETDEWEB)

    Herbst, Ronald Scott; Law, Jack Douglas; Todd, Terry Allen; Wood, D. J.; Garn, Troy Gerry; Wade, Earlen Lawrence

    2000-02-01

    Three unit operations for the removal of selected fission products, actinides, and RCRA metals (mercury and lead) have been successfully integrated and tested for extended run times with simulated INEEL acidic tank waste. The unit operations were ion exchange for Cs removal, followed by TRUEX solvent extraction for Eu (actinide surrogate), Hg, and Re (Tc surrogate) removal, and subsequent SREX solvent extraction for Sr and Pb removal. Approximately 45 L of simulated INTEC tank waste was first processed through three ion exchange columns in series for selective Cs removal. The columns were packed with a composite ammonium molybdophosphate-polyacrylonitrile (AMP-PAN) sorbent. The experimental breakthrough data were in excellent agreement with modeling predictions based on data obtained with much smaller columns. The third column (220 cm3) was used for polishing and Cs removal after breakthrough of the up-stream columns. The Cs removal was >99.83% in the ion exchange system without interference from other species. Most of the effluent from the ion exchange (IX) system was immediately processed through a TRUEX solvent extraction flowsheet to remove europium (americium surrogate), mercury and rhenium (technetium surrogate) from the simulated waste. The TRUEX flowsheet test was performed utilizing 23 stages of 3.3-cm centrifugal contactors. Greater than 99.999% of the Eu, 96.3% of the Hg, and 56% of the Re were extracted from the simulated feed and recovered in the strip and wash streams. Over the course of the test, there was no detectable build-up of any components in the TRUEX solvent. The raffinate from the TRUEX test was stored and subsequently processed several weeks later through a SREX solvent extraction flowsheet to remove strontium, lead, and Re (Tc surrogate) from the simulated waste. The SREX flowsheet test was performed using the same centrifugal contactors used in the TRUEX test after reconfiguration and the addition of three stages. Approximately 99.9% of

  14. Leachability of volatile fuel compounds from contaminated soils and the effect of plant exudates: A comparison of column and batch leaching tests.

    Science.gov (United States)

    Balseiro-Romero, María; Kidd, Petra S; Monterroso, Carmen

    2016-03-05

    Volatile fuel compounds such as fuel oxygenates (FO) (MTBE and ETBE) and BTEX (benzene, toluene, ethylbenzene and xylene) are some of the most soluble components of fuel. Characterizing the leaching potential of these compounds is essential for predicting their mobility through the soil profile and assessing the risk of groundwater contamination. Plant root exudates can play an important role in the modification of contaminant mobility in soil-plant systems, and such effects should also be considered in leaching studies. Artificially spiked samples of A and B horizons from an alumi-umbric Cambisol were leached in packed-columns and batch experiments using Milli-Q water and plant root exudates as leaching agents. The leaching potential and rate were strongly influenced by soil-contaminant interactions and by the presence of root exudates. Organic matter in A horizon preferably sorbed the most non-polar contaminants, lowering their leaching potential, and this effect was enhanced by the presence of root exudates. On the other hand, the inorganic components of the B horizon, showed a greater affinity for polar molecules, and the presence of root exudates enhanced the desorption of the contaminants. Column experiments resulted in a more realistic protocol than batch tests for predicting the leaching potential of volatile organic compounds in dissimilar soils. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. New approach to quantitative analysis of benzo[a]pyrene in food supplements by an immunochemical column test.

    Science.gov (United States)

    Beloglazova, Natalia V; Goryacheva, Irina Yu; de Saeger, Sarah; Scippo, Marie Louise; Niessner, Reinhard; Knopp, Dietmar

    2011-07-15

    A quantitative immunochemical rapid test for sensitive determination of benzo[a]pyrene (BAP) as a model analyte was developed making use of a handheld reader for results evaluation. The covalent immobilization of antibodies to different Sepharose gels, i.e., CNBr-activated Sepharose 4B and CNBr-activated Sepharose 4 Fast Flow was compared with adsorption to a polyethylene support. The lowest limits of detection (LOD) were 4 ng L(-1) and 40 ng L(-1), respectively, using optimized assay conditions. The developed test was applied to food supplements (garlic, black radish and maca), including a pretreatment procedure. LOD of 9 ng kg(-1) and linear range of 13-80 ng kg(-1) were obtained. Results of BAP determination in naturally contaminated samples were confirmed by high-performance liquid chromatography coupled to fluorescence detection and a good correlation was achieved. We suggest that the developed test format can be used to quantitative detection of the low molecular weight analytes, such as mycotoxins, pesticides, other pollutants in food and environmental samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Mobility of coated and uncoated TiO2 nanomaterials in soil columns--Applicability of the tests methods of OECD TG 312 and 106 for nanomaterials.

    Science.gov (United States)

    Nickel, Carmen; Gabsch, Stephan; Hellack, Bryan; Nogowski, Andre; Babick, Frank; Stintz, Michael; Kuhlbusch, Thomas A J

    2015-07-01

    Nanomaterials are commonly used in everyday life products and during their life cycle they can be released into the environment. Soils and sediments are estimated as significant sinks for those nanomaterials. To investigate and assess the behaviour of nanomaterials in soils and sediments standardized test methods are needed. In this study the applicability of two existing international standardized test guidelines for the testing of nanomaterials, OECD TG 106 "Adsorption/Desorption using a Bath Equilibrium Method" and the OECD TG 312 "Leaching in Soil Columns", were investigated. For the study one coated and two uncoated TiO2 nanomaterials were used, respectively. The results indicate that the OECD TG 106 is not applicable for nanomaterials. However, the test method according to OECD TG 312 was found to be applicable if nano-specific adaptations are applied. The mobility investigations of the OECD TG 312 indicated a material-dependent mobility of the nanomaterials, which in some cases may lead to an accumulation in the upper soil layers. Whereas no significant transport was observed for the uncoated materials for the double-coated material (coating with dimethicone and aluminiumoxide) a significant transport was detected and attributed to the coating. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. An analysis of lethal and sublethal interactions among type I and type II pyrethroid pesticide mixtures using standard Hyalella azteca water column toxicity tests.

    Science.gov (United States)

    Hoffmann, Krista Callinan; Deanovic, Linda; Werner, Inge; Stillway, Marie; Fong, Stephanie; Teh, Swee

    2016-10-01

    A novel 2-tiered analytical approach was used to characterize and quantify interactions between type I and type II pyrethroids in Hyalella azteca using standardized water column toxicity tests. Bifenthrin, permethrin, cyfluthrin, and lambda-cyhalothrin were tested in all possible binary combinations across 6 experiments. All mixtures were analyzed for 4-d lethality, and 2 of the 6 mixtures (permethrin-bifenthrin and permethrin-cyfluthrin) were tested for subchronic 10-d lethality and sublethal effects on swimming motility and growth. Mixtures were initially analyzed for interactions using regression analyses, and subsequently compared with the additive models of concentration addition and independent action to further characterize mixture responses. Negative interactions (antagonistic) were significant in 2 of the 6 mixtures tested, including cyfluthrin-bifenthrin and cyfluthrin-permethrin, but only on the acute 4-d lethality endpoint. In both cases mixture responses fell between the additive models of concentration addition and independent action. All other mixtures were additive across 4-d lethality, and bifenthrin-permethrin and cyfluthrin-permethrin were also additive in terms of subchronic 10-d lethality and sublethal responses. Environ Toxicol Chem 2016;35:2542-2549. © 2016 SETAC. © 2016 SETAC.

  18. Column: Every Last Byte

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-06-01

    Full Text Available Inheritance powder is the name that was given to poisons, especially arsenic, that were commonly used in the 17th and early 18th centuries to hasten the death of the elderly. For most of the 17th century, arsenic was deadly but undetectable, making it nearly impossible to prove that someone had been poisoned. The first arsenic test produced a gas—hardly something that a scientist could show to a judge. Faced with a growing epidemic of poisonings, doctors and chemists spent decades searching for something better.(see PDF for full column

  19. A comparative study of first-derivative spectrophotometry and column high-performance liquid chromatography applied to the determination of repaglinide in tablets and for dissolution testing.

    Science.gov (United States)

    AlKhalidi, Bashar A; Shtaiwi, Majed; AlKhatib, Hatim S; Mohammad, Mohammad; Bustanji, Yasser

    2008-01-01

    A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.

  20. Evaluation through column leaching tests of metal release from contaminated estuarine sediment subject to CO₂ leakages from Carbon Capture and Storage sites.

    Science.gov (United States)

    Payán, M Cruz; Galan, Berta; Coz, Alberto; Vandecasteele, Carlo; Viguri, Javier R

    2012-12-01

    The pH change and the release of organic matter and metals from sediment, due to the potential CO(2) acidified seawater leakages from a CCS (Carbon Capture and Storage) site are presented. Column leaching test is used to simulate a scenario where a flow of acidified seawater is in contact with recent contaminated sediment. The behavior of pH, dissolved organic carbon (DOC) and metals As, Cd, Cr, Cu, Ni, Pb, Zn, with liquid to solid (L/S) ratio and pH is analyzed. A stepwise strategy using empirical expressions and a geochemical model was conducted to fit experimental release concentrations. Despite the neutralization capacity of the seawater-carbonate rich sediment system, important acidification and releases are expected at local scale at lower pH. The obtained results would be relevant as a line of evidence input of CCS risk assessment, in an International context where strategies to mitigate the climate change would be applied. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Small Column Testing of Superlig 639 for Removal of 99Tc from Hanford Tank Waste Envelope C (Tank 241-AN-107)

    Energy Technology Data Exchange (ETDEWEB)

    DL Blanchard; DE Kurath; BM Rapko

    2000-06-28

    The current BNFL Inc. flow sheet for pretreating Hanford High-Level tank wastes includes the use of Superlig(reg.sign)639 (SL-639) in a dual column system for removing technetium-99 ({sup 99}Tc) from the aqueous fraction of the waste. This sorbent material has been developed and supplied by IBC Advanced Technologies, Inc., American Fork, UT. This report documents the results of testing the SL-639 sorbent with diluted waste [Na{sup +}] {approx} 5 M from Tank 241-AN-107 (an Envelope C waste, abbreviated AN-107) at Battelle Northwest Laboratories (BNW). The equilibrium behavior was assessed with batch contacts between the sorbent and the waste. Two AN-107 samples were used: (1) an archived sample from previous testing and (2) a more recent sample collected specifically for BNFL. A portion of the archive sample and all of the BNFL sample were treated to remove Sr-90 and transuranic elements (TRU). All samples had also been Cs decontaminated by ion exchange (IX), and were spiked with a technetium-95m ({sup 95m}Tc) pertechnetate tracer, {sup 95m}TcO{sub 4}{sup -}.The TcO{sub 4}{sup -} and total Tc K{sub d} values, assumed equal to the {sup 95m}Tc and {sup 99}Tc K{sub d}'s, respectively, are shown in Table S1. Values are averages of duplicates, which showed significant scatter. The total Tc K{sub d} for the BNFL sample is much lower than the TcO{sub 4}{sup -}, indicating that a large fraction of the {sup 99}Tc is not pertechnetate.

  2. Validated stability indicating liquid chromatographic determination of ebastine in pharmaceuticals after pre column derivatization: Application to tablets and content uniformity testing.

    Science.gov (United States)

    Ibrahim, Fawzia; Sharaf El-Din, Mohie Khaled; Eid, Manal Ibrahim; Wahba, Mary Elias Kamel

    2011-05-09

    An accurate, simple, sensitive and selective reversed phase liquid chromatographic method has been developed for the determination of ebastine in its pharmaceutical preparations. The proposed method depends on the complexation ability of the studied drug with Zn2+ ions. Reversed phase chromatography was conducted using an ODS C18 (150 × 4.6 mm id) stainless steel column at ambient temperature with UV-detection at 260 nm. A mobile phase containing 0.025%w/v Zn2+ in a mixture of (acetonitril/methanol; 1/4) and Britton Robinson buffer (65:35, v/v) adjusted to pH 4.2, has been used for the determination of ebastine at a flow rate of 1 ml/min. The calibration curve was rectilinear over the concentration range of 0.3 - 6.0 μg/ml with a detection limit (LOD) of 0.13 μg/ml, and quantification limit (LOQ) of 0.26 μg/ml. The proposed method was successfully applied for the analysis of ebastine in its dosage forms, the obtained results were favorably compared with those obtained by a comparison method. Furthermore, content uniformity testing of the studied pharmaceutical formulations was also conducted. The composition of the complex as well as its stability constant was also investigated. Moreover, the proposed method was found to be a stability indicating one and was utilized to investigate the kinetics of alkaline and ultraviolet induced degradation of the drug. The first-order rate constant and half life of the degradation products were calculated.

  3. Validated stability indicating liquid chromatographic determination of ebastine in pharmaceuticals after pre column derivatization: Application to tablets and content uniformity testing

    Directory of Open Access Journals (Sweden)

    Eid Manal

    2011-05-01

    Full Text Available Abstract An accurate, simple, sensitive and selective reversed phase liquid chromatographic method has been developed for the determination of ebastine in its pharmaceutical preparations. The proposed method depends on the complexation ability of the studied drug with Zn2+ ions. Reversed phase chromatography was conducted using an ODS C18 (150 × 4.6 mm id stainless steel column at ambient temperature with UV-detection at 260 nm. A mobile phase containing 0.025%w/v Zn2+ in a mixture of (acetonitril/methanol; 1/4 and Britton Robinson buffer (65:35, v/v adjusted to pH 4.2, has been used for the determination of ebastine at a flow rate of 1 ml/min. The calibration curve was rectilinear over the concentration range of 0.3 - 6.0 μg/ml with a detection limit (LOD of 0.13 μg/ml, and quantification limit (LOQ of 0.26 μg/ml. The proposed method was successfully applied for the analysis of ebastine in its dosage forms, the obtained results were favorably compared with those obtained by a comparison method. Furthermore, content uniformity testing of the studied pharmaceutical formulations was also conducted. The composition of the complex as well as its stability constant was also investigated. Moreover, the proposed method was found to be a stability indicating one and was utilized to investigate the kinetics of alkaline and ultraviolet induced degradation of the drug. The first-order rate constant and half life of the degradation products were calculated.

  4. Modeling Stone Columns

    OpenAIRE

    Castro Gonzalez, Jorge

    2017-01-01

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the "unit cell", longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, eith...

  5. Bench-scale testing of on-line control of column flotation using a novel analyzer. Revised final report, [October 1992--October 1993]: Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-27

    The main advantage of the project is that it allowed PTI to gain knowledge and experience about the proper approach, methods and hardware required to properly optimize and control column flotation performance. Many operational problems were incurred during the project, some of that PTI was able to solve during the project and other that must be overcome as the technology is further developed and commercialized. The key operating problems experienced with the KEN-FLOTE{sup TM} Column that must be further researched and overcome include: (1)The low concentrate solids content which limited the throughput capacity of the column, due to high froth washing requirements. The low concentrate solids content also lead to difficulty obtaining accurate On-Line Monitor measurements, due to the poor measurement sensitivity obtained with low solids content samples (particularly less than 5.0 wt %). (2) The higher-than-anticipated reagent dosages that undoubtedly contributed to the low solids content listed above, and also caused foaming problems within PTI`s On-Line Monitor. A defoaming reagent addition (Nalco 7810) was required to provide consistent sample size and reproducible On-Line Monitor counts for the concentrate samples collected within the circuit. PTI and UK`s CAER staff will continue to research alternative column design, particularly alternative air bubble generation and air distribution systems, to try to maximize column concentrate solids content while reducing reagent dosage requirements. In addition to the KEN-FLOTE{sup TM} Column operation there were also a number of hardware problems with PTI`s On-Line Quality Monitor that must be remedied for future commercial installations.

  6. Inflatable Column Structure

    Science.gov (United States)

    Hedgepeth, J. M.

    1985-01-01

    Lightweight structural member easy to store. Billowing between circumferential loops of fiber inflated column becomes series of cells. Each fiber subjected to same tension along entire length (though tension is different in different fibers). Member is called "isotensoid" column. Serves as jack for automobiles or structures during repairs. Also used as support for temporary bleachers or swimming pools.

  7. JCE Feature Columns

    Science.gov (United States)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  8. Nuclear reactor control column

    Science.gov (United States)

    Bachovchin, Dennis M.

    1982-01-01

    The nuclear reactor control column comprises a column disposed within the nuclear reactor core having a variable cross-section hollow channel and containing balls whose vertical location is determined by the flow of the reactor coolant through the column. The control column is divided into three basic sections wherein each of the sections has a different cross-sectional area. The uppermost section of the control column has the greatest cross-sectional area, the intermediate section of the control column has the smallest cross-sectional area, and the lowermost section of the control column has the intermediate cross-sectional area. In this manner, the area of the uppermost section can be established such that when the reactor coolant is flowing under normal conditions therethrough, the absorber balls will be lifted and suspended in a fluidized bed manner in the upper section. However, when the reactor coolant flow falls below a predetermined value, the absorber balls will fall through the intermediate section and into the lowermost section, thereby reducing the reactivity of the reactor core and shutting down the reactor.

  9. Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis

    Directory of Open Access Journals (Sweden)

    Bellino Michael J

    2010-05-01

    Full Text Available Abstract Background The objective of this study was to determine whether one can achieve stable fixation of a two column (transverse acetabular fracture by only fixing a single column with a locking plate and unicortical locking screws. We hypothesized that a locking plate applied to the anterior column of a transverse acetabular fracture would create a construct that is more rigid than a non-locking plate, and that this construct would be biomechanically comparable to two column fixation. Methods Using urethane foam models of the pelvis, we simulated transverse acetabular fractures and stabilized them with 1 an anterior column plate with bicortical screws, 2 an anterior locking plate with unicortical screws, 3 an anterior plate and posterior column lag screw, and 4 a posterior plate with an anterior column lag screw. These constructs were mechanically loaded on a servohydraulic material testing machine. Construct stiffness and fracture displacement were measured. Result and Discussion We found that two column fixation is 54% stiffer than a single column fixation with a conventional plate with bicortical screws. There was no significant difference between fixation with an anterior column locking plate with unicortical screws and an anterior plate with posterior column lag screw. We detected a non-significant trend towards more stiffness for the anterior locking plate compared to the anterior non-locking plate. Conclusion In conclusion, a locking plate construct of the anterior column provides less stability than a traditional both column construct with posterior plate and anterior column lag screw. However, the locking construct offers greater strength than a non-locking, bicortical construct, which in addition often requires extensive contouring and its application is oftentimes accompanied by the risk of neurovascular damage.

  10. Performance evaluation of granular activated carbon system at Pantex: Rapid small-scale column tests to simulate removal of high explosives from contaminated groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Henke, J.L.; Speitel, G.E. [Univ. of Texas, Austin, TX (United States). Dept. of Civil Engineering

    1998-08-01

    A granular activated carbon (GAC) system is now in operation at Pantex to treat groundwater from the perched aquifer that is contaminated with high explosives. The main chemicals of concern are RDX and HMX. The system consists of two GAC columns in series. Each column is charged with 10,000 pounds of Northwestern LB-830 GAC. At the design flow rate of 325 gpm, the hydraulic loading is 6.47 gpm/ft{sup 2}, and the empty bed contact time is 8.2 minutes per column. Currently, the system is operating at less than 10% of its design flow rate, although flow rate increases are expected in the relatively near future. This study had several objectives: Estimate the service life of the GAC now in use at Pantex; Screen several GACs to provide a recommendation on the best GAC for use at Pantex when the current GAC is exhausted and is replaced; Determine the extent to which natural organic matter in the Pantex groundwater fouls GAC adsorption sites, thereby decreasing the adsorption capacity for high explosives; and Determine if computer simulation models could match the experimental results, thereby providing another tool to follow system performance.

  11. The utility of testing tactile perception of direction of scratch as a sensitive clinical sign of posterior column dysfunction in spinal cord disorders.

    Science.gov (United States)

    Hankey, G J; Edis, R H

    1989-01-01

    Classical beliefs about the functions of the dorsal columns of the spinal cord have been attacked following recent evidence that position and vibration sensations may be carried in the dorsal spinocerebellar tracts. There is evidence that the one specific function of the dorsal columns is for the transmission of information concerning the direction of tactile cutaneous movement. Thirty normal controls, 43 patients with spinal cord disorders and 10 patients with functional disorders were examined prospectively using an easily administered "direction of scratch" protocol. Interpretation of the direction of a 2 cm vertical tactile cutaneous movement over the lower limbs was found to be accurate in normal controls and grossly inaccurate in patients with functional disorders, exceeding the error rate of guessing. Detection of direction of 2 cm scratch was moderately impaired in 11 of 13 patients with spastic paraparesis and preserved sensation to all other modalities and 23 of 24 patients with spastic paraparesis and impaired proprioception and/or vibration sensations. Direction of 2 cm scratch, proprioception and vibration sensations were preserved in the three cases with anterior spinal cord syndromes. It is proposed that tactile perception of direction of 2 cm scratch over the lower limbs is a sensitive sign of posterior column function which can be usefully incorporated into the clinical sensory examination in the evaluation of spinal cord disorders. PMID:2926427

  12. Microminiature gas chromatographic column

    Science.gov (United States)

    Donaldson, R. W., Jr.

    1972-01-01

    Techniques commonly used for fabrication of integrated circuits are utilized to produce long capillary tubes for microminiature chromatographs. Method involves bonding of flat silicon plate to top of spirally grooved silicon chip to close groove and form capillary column.

  13. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  14. Towards Atomic Column-by-Column Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Pennycook, S.J.; Rafferty, B.

    1998-09-06

    The optical arrangement of the scanning transmission electron microscope (STEM) is ideally suited for performing analysis of individual atomic columns in materials. Using the incoherent Z-contrast image as a reference, and arranging incoherent conditions also for the spectroscopy, a precise correspondence is ensured between features in the inelastic image and elastic signals. In this way the exact probe position needed to maximise the inelastic signal from a selected column can be located and monitored during the analysis using the much higher intensity elastic signal. Although object functions for EELS are typically less than 1 {Angstrom} full width at half maximum, this is still an order of magnitude larger than the corresponding object functions for elastic (or diffuse) scattering used to form the Z-contrast image. Therefore the analysis is performed with an effective probe that is significantly broader than that used for the reference Z-contrast image. For a 2.2 {Angstrom} probe the effective probe is of the order of 2.5 {Angstrom}, while for a 1.3 {Angstrom} probe the effective probe is 1.6 {Angstrom}. Such increases in effective probe size can significantly reduce or even eliminate contrast between atomic columns that are visible in the image. However, this is only true if we consider circular collector apertures. Calculations based upon the theory of Maslen and Rossouw (Maslen and Rossouw 1984; Rossouw and Maslen 1984) show that employing an annular aperture can reduce the FWHM of the inelastic object function down to values close 0.1 {Angstrom}. With practical aperture sizes it should be possible to achieve this increased spatial resolution without loosing too much signal.

  15. Comparison of monolithic silica and polymethacrylate capillary columns for LC.

    Science.gov (United States)

    Moravcová, Dana; Jandera, Pavel; Urban, Jiri; Planeta, Josef

    2004-07-01

    Organic polymer monolithic capillary columns were prepared in fused-silica capillaries by radical co-polymerization of ethylene dimethacrylate and butyl methacrylate monomers with azobisisobutyronitrile as initiator of the polymerization reaction in the presence of various amounts of porogenic solvent mixtures and different concentration ratios of monomers and 1-propanol, 1,4-butanediol, and water. The chromatographic properties of the organic polymer monolithic columns were compared with those of commercial silica-based particulate and monolithic capillary and analytical HPLC columns. The tests included the determination of H-u curves, column permeabilities, pore distribution by inversed-SEC measurements, methylene and polar selectivities, and polar interactions with naphthalenesulphonic acid test samples. Organic polymer monolithic capillary columns show similar retention behaviour to chemically bonded alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have lower methylene selectivities and do not show polar interactions with sulphonic acids. The commercial capillary and analytical silica gel-based monolithic columns showed similar selectivities and provided symmetrical peaks, indicating no significant surface heterogeneities. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra-column contributions. With 0.3 mm ID capillary columns, corrections for extra-column volume contributions are sufficient, but to obtain true information on the efficiency of 0.1 mm ID capillary columns, the experimental bandwidths should be corrected for extra-column contributions to peak broadening.

  16. Removal efficiency of multiple poly- and perfluoroalkyl substances (PFASs) in drinking water using granular activated carbon (GAC) and anion exchange (AE) column tests.

    Science.gov (United States)

    McCleaf, Philip; Englund, Sophie; Östlund, Anna; Lindegren, Klara; Wiberg, Karin; Ahrens, Lutz

    2017-09-01

    Poly- and perfluoroalkyl substances (PFASs) have been detected in drinking water at relatively high concentrations throughout the world which has led to implementation of regulatory guidelines for specific PFASs in drinking water in several European countries and in the U.S. The Swedish National Food Agency has determined that the drinking water of over one third of the country's municipal consumers is at risk or already affected by PFAS contamination. The present study investigated the effects of perfluorocarbon chain length, functional group and isomer structure (branched or linear) on removal of multiple PFASs using granular activated carbon (GAC, Filtrasorb ® 400) and anion exchange (AE, Purolite ® A600) column experiments. The removal of 14 different PFASs, i.e. the C 3 C 11 , C 14 perfluoroalkyl carboxylic acids (PFCAs) (PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFNA, PFDA, PFUnDA, PFDoDA, PFTeDA), perfluorooctane sulfonamide (FOSA), and the C 4 , C 6 , C 8 perfluoroalkyl sulfonic acids (PFSAs) (PFBS, PFHxS, PFOS), was monitored for a 217 day period. The results indicate the selective nature of PFAS removal as the absorbents are loaded with PFASs and dissolved organic carbon (DOC). A clear relationship between perfluorocarbon chain length and removal efficiency of PFASs using GAC and AE was found while PFASs with sulfonate functional groups displayed greater removal efficiency than those with carboxylate groups. Similarly, time to column breakthrough increased with increasing perfluorocarbon chain length and was greater for the PFSAs than the PFCAs for both GAC and AE. Shorter carbon chained PFASs such as PFBA, PFPeA, PFHxA showed desorption behavior and long-chained PFASs showed increased removal towards the end of the experiment indicating agglomeration or micelle development. Linear isomers of PFOS, PFHxS, and perfluorooctane sulfonamide (FOSA) had greater column removal efficiencies using GAC (and also for AE at greater bed volume throughput) than the branched

  17. Interpretation of actinide-distribution data obtained from non-destructive and destructive post-test analyses of an intact-core column of Culebra dolomite.

    Science.gov (United States)

    Perkins, W G; Lucero, D A

    2001-02-01

    The US Department of Energy (DOE), with technical assistance from Sandia National Laboratories, has successfully received EPA certification and opened the Waste Isolation Pilot Plant (WIPP), a nuclear waste disposal facility located approximately 42 km east of Carlsbad, NM. Performance assessment (PA) analyses indicate that human intrusions by inadvertent, intermittent drilling for resources provide the only credible mechanisms for significant releases of radionuclides from the disposal system. For long-term brine releases, migration pathways through the permeable layers of rock above the Salado formation are important. Major emphasis is placed on the Culebra Member of the Rustler Formation because this is the most transmissive geologic layer overlying the WIPP site. In order to help quantify parameters for the calculated releases, radionuclide transport experiments have been carried out using intact-core columns obtained from the Culebra dolomite member of the Rustler Formation within the WIPP site. This paper deals primarily with results of analyses for 241Pu and 241Am distributions developed during transport experiments in one of these cores. Transport experiments were done using a synthetic brine that simulates Culebra brine at the core recovery location (the WIPP air-intake shaft (AIS)). Hydraulic characteristics (i.e., apparent porosity and apparent dispersion coefficient) for intact-core columns were obtained via experiments using the conservative tracer 22Na. Elution experiments carried out over periods of a few days with tracers 232U and 239Np indicated that these tracers were weakly retarded as indicated by delayed elution of the species. Elution experiments with tracers 241Pu and 241Am were attempted but no elution of either species has been observed to date, including experiments of many months' duration. In order to quantify retardation of the non-eluted species 241Pu and 241Am after a period of brine flow, non-destructive and destructive analyses of

  18. Behavior of reinforced concrete columns strenghtened by partial jacketing

    Directory of Open Access Journals (Sweden)

    D. B. FERREIRA

    Full Text Available This article presents the study of reinforced concrete columns strengthened using a partial jacket consisting of a 35mm self-compacting concrete layer added to its most compressed face and tested in combined compression and uniaxial bending until rupture. Wedge bolt connectors were used to increase bond at the interface between the two concrete layers of different ages. Seven 2000 mm long columns were tested. Two columns were cast monolithically and named PO (original column e PR (reference column. The other five columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and other columns had a 155 mm by 250mm cross section after the strengthening procedure. Results show that the ultimate resistance of the strengthened columns was more than three times the ultimate resistance of the original column PO, indicating the effectiveness of the strengthening procedure. Detachment of the new concrete layer with concrete crushing and steel yielding occurred in the strengthened columns.

  19. Interpretation of data obtained from non-destructive and destructive post-test analyses of an intact-core column of culebra dolomite

    Energy Technology Data Exchange (ETDEWEB)

    Lucero, Daniel L.; Perkins, W. George

    1998-09-01

    The U.S. Department of Energy (DOE) has been developing a nuclear waste disposal facility, the Waste Isolation Pilot Plant (WIPP), located approximately 42 km east of Carlsbad, New Mexico. The WIPP is designed to demonstrate the safe disposal of transuranic wastes produced by the defense nuclear-weapons program. Pefiormance assessment analyses (U.S. DOE, 1996) indicate that human intrusion by inadvertent and intermittent drilling for resources provide the only credible mechanisms for significant releases of radionuclides horn the disposal system. These releases may occur by five mechanisms: (1) cuttings, (2) cavings, (3) spallings, (4) direct brine releases, and (5) long- term brine releases. The first four mechanisms could result in immediate release of contaminant to the accessible environment. For the last mechanisq migration pathways through the permeable layers of rock above the Salado are important, and major emphasis is placed on the Culebra Member of the Rustler Formation because this is the most transmissive geologic layer in the disposal system. For reasons of initial quantity, half-life, and specific radioactivity, certain isotopes of T~ U, Am, and Pu would dominate calculated releases from the WIPP. In order to help quantifi parameters for the calculated releases, radionuclide transport experiments have been carried out using five intact-core columns obtained from the Culebra dolomite member of the Rustler Formation within the Waste Isolation Pilot Pknt (WIPP) site in southeastern New Mexico. This report deals primarily with results of analyses for 241Pu and 241Am distributions developed during transport experiments in one of these cores. All intact-core column transport experiments were done using Culebra-simukmt brine relevant to the core recovery location (the WIPP air-intake shaft - AK). Hydraulic characteristics (i.e., apparent porosity and apparent dispersion coefficient) for intact-core columns were obtained via experiments using conservative

  20. Columns in Clay

    Science.gov (United States)

    Leenhouts, Robin

    2010-01-01

    This article describes a clay project for students studying Greece and Rome. It provides a wonderful way to learn slab construction techniques by making small clay column capitols. With this lesson, students learn architectural vocabulary and history, understand the importance of classical architectural forms and their influence on today's…

  1. Practical column design guide

    CERN Document Server

    Nitsche, M

    2017-01-01

    This book highlights the aspects that need to be considered when designing distillation columns in practice. It discusses the influencing parameters as well as the equations governing them, and presents several numerical examples. The book is intended both for experienced designers and for those who are new to the subject.

  2. Nine Words - Nine Columns

    DEFF Research Database (Denmark)

    Trempe Jr., Robert B.; Buthke, Jan

    2016-01-01

    This book records the efforts of a one-week joint workshop between Master students from Studio 2B of Arkitektskolen Aarhus and Master students from the Harbin Institute of Technology in Harbin, China. The workshop employed nine action words to instigate team-based investigation into the effects o...... as formwork for the shaping of wood veneer. The resulting columns ‘wear’ every aspect of this design pipeline process and display the power of process towards an architectural resolution....

  3. Behavior of Columns During Earthquakes

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The behavior of columns during earthquakes is very important since column failures may lead to additional structural failures and result in total building collapses....

  4. A CONCEPTUAL DESIGN OF NEUTRON COLLIMATOR IN THE THERMAL COLUMN OF KARTINI RESEARCH REACTOR FOR IN VITRO AND IN VIVO TEST OF BORON NEUTRON CAPTURE THERAPY

    Directory of Open Access Journals (Sweden)

    Nina Fauziah

    2015-03-01

    Full Text Available Studies were carried out to design a collimator which results in epithermal neutron beam for IN VITRO and IN VIVO of Boron Neutron Capture Therapy (BNCT at the Kartini research reactor by means of Monte Carlo N-Particle (MCNP codes. Reactor within 100 kW of thermal power was used as the neutron source. The design criteria were based on recommendation from the International Atomic Energy Agency (IAEA. All materials used were varied in size, according to the value of mean free path for each material. MCNP simulations indicated that by using 5 cm thick of Ni as collimator wall, 60 cm thick of Al as moderator, 15 cm thick of 60Ni as filter, 2 cm thick of Bi as γ-ray shielding, 3 cm thick of 6Li2CO3-polyethylene as beam delimiter, with 1 to 5 cm varied aperture size, epithermal neutron beam with maximum flux of 7.65 x 108 n.cm-2.s-1 could be produced. The beam has minimum fast neutron and γ-ray components of, respectively, 1.76 x 10-13 Gy.cm2.n-1 and 1.32 x 10-13 Gy.cm2.n-1, minimum thermal neutron per epithermal neutron ratio of 0.008, and maximum directionality of 0.73. It did not fully pass the IAEA’s criteria, since the epithermal neutron flux was below the recommended value, 1.0 x 109 n.cm-2.s-1. Nonetheless, it was still usable with epithermal neutron flux exceeding 5.0 x 108 n.cm-2.s-1. When it was assumed that the graphite inside the thermal column was not discharged but only the part which was going to be replaced by the collimator, the performance of the collimator became better within the positive effect from the surrounding graphite that the beam resulted passed all criteria with epithermal neutron flux up to 1.68 x 109 n.cm-2.s-1. Keywords: design, collimator, epithermal neutron beam, BNCT, MCNP, criteria   Telah dilakukan penelitian tentang desain kolimator yang menghasilkan radiasi netron epitermal untuk uji in vitro dan in vivo pada Boron Neutron Capture Therapy (BNCT di Reaktor Riset Kartini dengan menggunakan program Monte

  5. of reinforced concrete columns

    Directory of Open Access Journals (Sweden)

    Anna Szcześniak

    2015-09-01

    Full Text Available The paper presents the modification of the dynamic relaxation method in order to increase its effectiveness in the range of the post-critical analysis. For this purpose, the arc-length parameter on the equilibrium path was introduced into the computational procedure. The additional constraints equation that combines increment of load parameter and the vector of displacement increments with the arc-length increment on the solution path was incorporated to analysis of the equations of motion. Solution of nonlinear equilibrium equations is obtained recursively in subsequent pseudo-time instants. The proposed method allows for tracking the global softening phenomenon of the structural element in the post-critical range, which leads to failure. We ran numerical experiments for the reinforced concrete eccentrically loaded column. Our comparative analysis with previously published numerical results demonstrated that the proposed computational method is effective.[b]Keywords[/b]: reinforced concrete columns, dynamic relaxation method, arc-length method, load-carrying capacity

  6. Cesium ion exchange using actual waste: Column size considerations

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, K.P.

    1996-04-01

    It is presently planned to remove cesium from Hanford tank waste supernates and sludge wash solutions using ion exchange. To support the development of a cesium ion exchange process, laboratory experiments produced column breakthrough curves using wastes simulants in 200 mL columns. To verify the validity of the simulant tests, column runs with actual supernatants are being planned. The purpose of these actual waste tests is two-fold. First, the tests will verify that use of the simulant accurately reflects the equilibrium and rate behavior of the resin compared to actual wastes. Batch tests and column tests will be used to compare equilibrium behaviors and rate behaviors, respectively. Second, the tests will assist in clarifying the negative interactions between the actual waste and the ion exchange resin, which cannot be effectively tested with simulant. Such interactions include organic fouling of the resin and salt precipitation in the column. These effects may affect the shape of the column breakthrough curve. The reduction in column size also may change the shape of the curve, making the individual effects even more difficult to sort out. To simplify the evaluation, the changes due to column size must be either understood or eliminated. This report describes the determination of the column size for actual waste testing that best minimizes the effect of scale-down. This evaluation will provide a theoretical basis for the dimensions of the column. Experimental testing is still required before the final decision can be made. This evaluation will be confined to the study of CS-100 and R-F resins with NCAW simulant and to a limited extent DSSF waste simulant. Only the cesium loading phase has been considered.

  7. SPIRAL CONTACTOR FOR SOLVENT EXTRACTION COLUMN

    Science.gov (United States)

    Cooley, C.R.

    1961-06-13

    The patented extraction apparatus includes a column, perforated plates extending across the column, liquid pulse means connected to the column, and an imperforate spiral ribbon along the length of the column.

  8. European Analytical Column

    DEFF Research Database (Denmark)

    Karlberg, B.; Grasserbauer, M.; Andersen, Jens Enevold Thaulov

    2009-01-01

    The European Analytical Column has once more invited a guest columnist to give his views on various matters related to analytical chemistry in Europe. This year, we have invited Professor Manfred Grasserbauer of the Vienna University of Technology to present some of the current challenges...... for European analytical chemistry. During the period 2002–07, Professor Grasserbauer was Director of the Institute for Environment and Sustainability, Joint Research Centre of the European Commission (EC), Ispra, Italy. There is no doubt that many challenges exist at the present time for all of us representing...... a major branch of chemistry, namely analytical chemistry. The global financial crisis is affecting all branches of chemistry, but analytical chemistry, in particular, since our discipline by tradition has many close links to industry. We have already noticed decreased industrial commitment with respect...

  9. Column: File Cabinet Forensics

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-12-01

    Full Text Available Researchers can spend their time reverse engineering, performing reverse analysis, or making substantive contributions to digital forensics science. Although work in all of these areas is important, it is the scientific breakthroughs that are the most critical for addressing the challenges that we face.Reverse Engineering is the traditional bread-and-butter of digital forensics research. Companies like Microsoft and Apple deliver computational artifacts (operating systems, applications and phones to the commercial market. These artifacts are bought and used by billions. Some have evil intent, and (if society is lucky, the computers end up in the hands of law enforcement. Unfortunately the original vendors rarely provide digital forensics tools that make their systems amenable to analysis by law enforcement. Hence the need for reverse engineering.(see PDF for full column

  10. Partial strengthening of R.C square columns using CFRP

    Directory of Open Access Journals (Sweden)

    Ahmed Shaban Abdel-Hay

    2014-12-01

    An experimental program was undertaken testing ten square columns 200 × 200 × 2000 mm. One of them was a control specimen and the other nine specimens were strengthened with CFRP. The main parameters studied in this research were the compressive strength of the upper part, the height of the upper poor concrete part, and the height of CFRP wrapped part of column. The experimental results including mode of failure, ultimate load, concrete strain, and fiber strains were analyzed. The main conclusion of this research was, partial strengthening of square column using CFRP can be permitted and gives good results of the column carrying capacity.

  11. Temperature-compensated 8-bit column driver for AMLCD

    Science.gov (United States)

    Dingwall, Andrew G. F.; Lin, Mark L.

    1995-06-01

    An all-digital, 5 V input, 50 Mhz bandwidth, 10-bit resolution, 128- column, AMLCD column driver IC has been designed and tested. The 10-bit design can enhance display definition over 6-bit nd 8-bit column drivers. Precision is realized with on-chip, switched-capacitor DACs plus transparently auto-offset-calibrated, opamp outputs. Increased resolution permits multiple 10-bit digital gamma remappings in EPROMs over temperature. Driver IC features include externally programmable number of output column, bi-directional digital data shifting, user- defined row/column/pixel/frame inversion, power management, timing control for daisy-chained column drivers, and digital bit inversion. The architecture uses fewer reference power supplies.

  12. Comparison of two column characterisation systems based on pharmaceutical applications.

    Science.gov (United States)

    Haghedooren, Erik; Németh, Tamás; Dragovic, Sanja; Noszál, Béla; Hoogmartens, Jos; Adams, Erwin

    2008-05-02

    A useful column characterisation system should help chromatographers to select the most appropriate column to use, e.g. when a particular chromatographic column is not available or when facing the dilemma of selecting a suitable column for analysis according to an official monograph. Official monographs of the European Pharmacopoeia and the United States Pharmacopeia are not allowed to mention the brand name of the stationary phase used for the method development. Also given the overwhelming offer of several hundreds of commercially available reversed-phase liquid chromatographic columns, the choice of a suitable column could be difficult sometimes. To support rational column selection, a column characterisation study was started in our laboratory in 2000. In the same period, Euerby et al. also developed a column characterisation system, which is now released as Column Selector by ACD/Labs. The aim of this project was to compare the two existing column characterisation systems, i.e. the KUL system and the Euerby system. Other research groups active in this field will not be discussed here. Euerby et al. developed a column characterisation system based on 6 test parameters, while the KUL system is based on 4 chromatographic parameters. Comparison was done using a set of 63 columns. For 7 different pharmaceutical separations (fluoxetine, gemcitabine, erythromycin, tetracycline, tetracaine, amlodipine and bisacodyl), a ranking was built based on an F-value (KUL method) or Column Difference Factor value (Euerby method) versus a (virtual) reference column. Both methods showed a similar ranking. The KUL and Euerby methods do not perfectly match, but they yield very similar results, allowing with a relatively high certainty, the selection of similar or dissimilar columns as compared to a reference column. An analyst that uses either of the two methods, will end up with a similar ranking. From a practical point of view, it must be noted that the KUL method only includes 4

  13. Repair of earthquake damaged bridge columns with fractured bars.

    Science.gov (United States)

    2013-07-01

    The objective of this study is to repair three, half-scale RC bridge columns that will be tested to failure under slow cyclic loading. : These columns will have fractured longitudinal and transverse steel. The ultimate goal is to develop repair metho...

  14. Seismic Behaviour of Synthetic-Frc Columns

    Science.gov (United States)

    Paultre, P.; Eid, R.

    2017-09-01

    Inclusion of short discrete fibres into the concrete mixture can increase the compressive strength and ductility of normal-strength concrete (NSC) and high-strength concrete (HSC) column specimens under compressive loading as already has been shown by several studies. Concrete design codes ensure ductile behaviour of columns by setting a requirement for a minimum amount of transverse steel reinforcement. Therefore, the inclusion of discrete short fibres into the concrete mixture combined with a reduced amount of lateral reinforcement can be an alternative to the latter full amount required by the codes. This paper presents tests that were performed on large-scale fibre-reinforced NSC circular columns under cyclic flexure and constant axial load simulating earthquake loading. The aim of this test program is to examine the combined confinement effect of steel or synthetic fibres and the transverse steel reinforcement type (spirals or hoops) on the structural performance of RC columns. The results show that in terms of ductility and energy dissipation, the behaviour of the fibre-reinforced concrete (FRC) specimens is improved compared to the nonfibrous ones. This behaviour is also predicted by the proposed confinement model which takes into account the mechanical and the geometrical properties of the concrete and the reinforcement as well as those of the fibres.

  15. Soil column leaching of pesticides.

    Science.gov (United States)

    Katagi, Toshiyuki

    2013-01-01

    persistence (DT50) of the pesticide, and its sorption/desorption(Koc) characteristics. These parameters may vary for the same pesticide from geographic site-to-site and with soil depth. The interactions that normally occur between pesticides and dissolved organic matter (DOM) or WDC are yet other factors that may complicate pesticide leaching behavior.The soil mobility of pesticides is normally tested both in the laboratory and in the field. Lab studies are initially performed to give researchers a preliminary appraisal of the relative mobility of a pesticide. Later, field lysimeter studies can be performed to provide more natural leaching conditions that emulate the actual field use pattern. Lysimeter studies give the most reliable information on the leaching behavior of a pesticide under field conditions, but these studies are time-consuming and expensive and cannot be performed everywhere. It is for this reason that the laboratory soil column leaching approach is commonly utilized to profile the mobility of a pesticide,and appraise how it behaves in different soils, and relative to other pesticides.Because the soil structure is chemically and physically heterogenous, different pesticide tests may produce variable DT50 and Koc values; therefore, initial pesticide mobility testing is undertaken in homogeneously packed columns that contain two or more soils and are eluted at constant flow rates. Such studies are done in duplicate and utilize a conservative tracer element. By fitting an appropriate mathematical model to the breakthrough curve of the conservative tracer selected,researchers determine key mobility parameters, such as pore water velocity, the column-specific dispersion coefficient, and the contribution of non equilibrium transport processes. Such parameters form the basis for estimating the probable transport and degradation rates that will be characteristic of the tested pesticide. Researchers also examine how a pesticide interacts with soil DOM and WDC, and

  16. Safety barriers and lighting columns.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1972-01-01

    Problems arising from the sitting of lighting columns on the central reserve are reviewed, and remedial measures such as break-away lighting supports and installation of safety fences on the central reserve on both sides of the lighting columns are examined.

  17. Developing the bundled glass column

    NARCIS (Netherlands)

    Oikonomopoulou, F.; Bristogianni, T; Veer, F.A.; Nijsse, R.; da Sousa Cruz, Paulo J.

    In this paper a bundled glass column is presented as a promising solution for a completely transparent, almost dematerialized structural compressive element. The aim is to ob-tain a glass column that can safely carry loads, achieve a high visual result and be relatively eas-ily manufactured.

  18. The counterintuitive role of extra-column volume in the determination of column efficiency and scaling of chromatographic processes.

    Science.gov (United States)

    Schultze-Jena, A; Boon, M A; Bussmann, P J Th; Janssen, A E M; van der Padt, A

    2017-04-14

    In industrial liquid separation processes chromatography often has a key function in the optimization of yield and purity. For the design of an industrial system, chromatographic processes are generally simulated using mathematical models, tested and optimized at laboratory level, and then scaled up to pilot and subsequently industrial scale. To describe the system, experimental data and model data need to be fitted and extra column contribution must be determined. This paper describes the influence of extra-column volume on overall separation efficiency for lab scale and its impact on the design of large scale systems. Measurement of extra-column contribution was investigated in terms of mean retention time and variance using two different methods the commonly used zero dead volume connector and as an alternative the zero length column. Further a technique is presented to estimate extra-column contribution to band broadening for different injection volumes, velocities, and tracers based on representative measurements. When scaling up, often contribution of extra-column volume from laboratory equipment is neglected assuming to be on the safe side, however column efficiency is often lower than efficiency measured for the entire chromatographic system. Relation between system efficiency and column efficiency was investigated using laboratory data and the lumped kinetic model. Depending on the ratio of extra-column volume to retention volume in the system, deduced column efficiency was up to 20% smaller than overall system efficiency. This ratio revealed the misleading nature of the term efficiency loss, when describing influence of extra-column volume on column efficiency. A scheme, which relates the relative variance of the system to the relative extra-column volume, provided an assessment of under- or overestimation of column efficiency. In this article it is shown how scaling up a system based on laboratory data, where extra-column volume contribution is not

  19. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  20. HETP evaluation of structured packing distillation column

    Directory of Open Access Journals (Sweden)

    A. E. Orlando Jr.

    2009-09-01

    Full Text Available Several tests with a hydrocarbon mixture of known composition (C8-C14, obtained from DETEN Chemistry S.A., have been performed in a laboratory distillation column, having 40mm of nominal diameter and 2.2m high, with internals of Sulzer DX gauze stainless steel structured packing. The main purpose of this work was to evaluate HETP of a structured packing laboratory scale distillation column, operating continuously. Six HETP correlations available in the literature were compared in order to find out which is the most appropriate for structured packing columns working with medium distillates. Prior to the experimental tests, simulation studies using commercial software PRO/II® were performed in order to establish the optimum operational conditions for the distillation, especially concerning operating pressure, top and bottom temperatures, feed location and reflux ratio. The results of PRO/II® were very similar to the analysis of the products obtained during continuous operation, therefore permitting the use of the properties calculated by that software on the theoretical models investigated. The theoretical models chosen for HETP evaluation were: Bravo, Rocha and Fair (1985; Rocha, Bravo and Fair (1993, 1996; Brunazzi and Pagliant (1997; Carlo, Olujić and Pagliant (2006; Olujić et al., (2004. Modifications concerning calculation of specific areas were performed on the correlations in order to fit them for gauze packing HETP evaluation. As the laboratory distillation column was operated continuously, different HETP values were found by the models investigated for each section of the column. The low liquid flow rates in the top section of the column are a source of error for HETP evaluation by the models; therefore, more reliable HETP values were found in the bottom section, in which liquid flow rates were much greater. Among the theoretical models, Olujić et al. (2004 has shown good results relative to the experimental tests. In addition, the

  1. Column-Oriented Database Systems (Tutorial)

    NARCIS (Netherlands)

    D. Abadi; P.A. Boncz (Peter); S. Harizopoulos

    2009-01-01

    textabstractColumn-oriented database systems (column-stores) have attracted a lot of attention in the past few years. Column-stores, in a nutshell, store each database table column separately, with attribute values belonging to the same column stored contiguously, compressed, and densely packed, as

  2. EX1201 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1201: Ship Shakedown and Patch Tests...

  3. EX1301 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1301: Ship Shakedown and Patch Test...

  4. EX1601 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1601: Transit and Mission Patch Test...

  5. EX1302 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1302: Ship Shakedown, Patch Test and...

  6. EX1101 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1101: Ship Shakedown and Patch Tests...

  7. The selection of suitable columns for a reversed-phase liquid chromatographic separation of beta-lactam antibiotics and related substances via chromatographic column parameters.

    Science.gov (United States)

    Zhang, Wei-qing; Hu, Qiu-xin; Zhang, Xia; Li, Ya-ping; Wang, Ming-juan; Hu, Chang-qin

    2014-01-03

    The selection of RP-LC columns suitable for a particular analysis in official compendia is difficult as only a general description of the stationary phase in the description of a LC method is given. General methods to characterize RP-LC columns often assume that each of the column parameters is equally important. This can cause the user to select columns inappropriate for particular analyses. This paper focuses on the relationship between the critical peak pairs and the column parameters (H, S, A, B, and C) in the Snyder/Dolan column characterization methodology to find the key parameters influencing real separations. Some varieties of β-lactam antibiotics and their related compounds were used as test compounds. We found column parameter A to be the most important factor affecting their separation. Parameters B and C also played an important role in some separation processes. This indicated that the hydrogen bonding of column and solute can directly affect the separation of β-lactam antibiotics. Choosing columns for which column parameter A is near 0.1 can facilitate the ideal separations of impurities from β-lactam antibiotics. The most suitable column for any common pharmaceutical analysis could be selected easily if the key column parameters would be given in the description of the chromatographic method. For these reasons, key column parameters should be listed in the monographs of official compendia. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Effects of water content on reactive transport of Sr in Chernobyl sand columns

    Energy Technology Data Exchange (ETDEWEB)

    Szenknect, S. [CEA, Tracers Applications Laboratory, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Dewiere, L.; Ardois, C. [IRSN, Environment and Emergency Operations Division, Geosphere-related Risk Analysis Department, BP 17, 92262 Fontenay-aux-Roses (France); Gaudet, J.P. [UMR 5564 (CNRS/IRD/INPG/UJF), LTHE, BP 53, 38041 Grenoble Cedex 9 (France)

    2005-07-01

    Full text of publication follows: While transport of non-reactive solutes has been studied extensively in unsaturated porous media, much less is known about the factors that control the transport of sorbing solutes in unsaturated conditions. Three laboratory techniques were used to analyze the transport of Sr in the aeolian sand from Chernobyl Pilot Site [1] in both saturated and unsaturated flow conditions. Batch experiments were performed to study the chemical equilibrium state of the soil/solution system. Stirred flow-through reactor (SFTR) experiments were performed to study the kinetics and reversibility of sorption reactions at the surface of solid particles. Column experiments were also performed in saturated and unsaturated steady flow conditions. Experimental data pointed out a non-linear, instantaneous and reversible sorption process of Sr. A suitable cation-exchange model was used to describe the solute/soil reaction. The former model was coupled with transport models to describe behavior of Sr in saturated [2] and unsaturated flow conditions. Transport properties of sand packed columns have been determined with an inert tracer (HTO). BTCs obtained under saturated conditions exhibit a small amount of dispersion compared to those obtained under unsaturated conditions. Classical advection-dispersion model described successfully saturated tritium breakthrough curves (BTCs), whereas a mobile-immobile model (MIM) was required to described asymmetrical unsaturated BTCs. The MIM assumes that the porous medium contains a mobile water phase in which convective-dispersive transport occurs, and a immobile water phase with which solutes can exchange with a first order kinetic. In our experiments, transport by advection in the mobile phase is the predominant process whatever the flow conditions and mass transfer rate between the mobile and immobile regions is the predominant process for broadening the BTCs. Since dispersion is blurred by mass transfer resistance, the

  9. Water Column Sonar Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The collection and analysis of water column sonar data is a relatively new avenue of research into the marine environment. Primary uses include assessing biological...

  10. Finite element analysis on seismic performance of EWECS composite column

    Directory of Open Access Journals (Sweden)

    Fauzan

    2017-01-01

    Full Text Available A new hybrid Engineering Wood Encased Concrete-Steel (EWECS structural system is developed in Japan to solve the limitation of story number for wooden structure. In this structural system, the EWECS column consist of concrete encased steel (CES core and wood panel as a column cover. An experimental study has been done to investigate the seismic performance of the EWECS column, which is compared with CES column without concrete cover. The main parameter is the presence of wood panel. In order to validate the experimental results, a 3D finite element (FE model is built by using ANSYS APDL v.14. The FE results indicate that FE EWECS column model has excellent performance, which has a stable spindle-shape hysteresis loops. The presence of wood panel contributes to improve the maximum flexural capacity of the EWECS column about 13%. In addition, the stress distribution on the FE models has good correlation with failure mode of the EWECS column specimens. Generally, the numerical results are able to accurately simulate the seismic behaviour of the EWECS column on test results.

  11. Seismic Behavior of Short Concrete Columns with Prestressing Steel Wires

    Directory of Open Access Journals (Sweden)

    Deng Zong-Cai

    2014-01-01

    Full Text Available The seismic behavior of short circular reinforced concrete columns was studied by testing seven columns retrofitted with prestressing steel wire (PSW, subjected to combined constant axial compression and lateral cyclic load. The main test parameters were configuration index of PSW, prestressing level of PSW, and axial compression ratio. An analysis and discussion of the test results including failure mode, hysteresis curves, skeleton curves, ductility, and degradation of stiffness was done. The results show that the seismic performance of the retrofitted specimens could be effectively enhanced even if the axial compression ratio of columns reached 0.81. The ductility index and the energy absorption capacity of the retrofitted specimens increase with the prestressing level of PSW. The formulas for calculating shear capacity of RC short columns strengthened with PSW were proposed which may be useful for future engineering designs and researches.

  12. Solving Leak Testing Challenges

    National Research Council Canada - National Science Library

    John Sprovieri

    2007-01-01

    .... InterTech provided two Model 1075 pressure-decay leak detectors to perform the three tests-a leak test at 220 inches of water column, a leak test at 5 inches of water column, and a forward direction...

  13. Behavior of Short Columns Reinforced with Welded Wire Fabric as Transverse Reinforcement under Concentric Loading

    OpenAIRE

    Satjapan LEELATANON; Trakool ARAMRAKS

    2008-01-01

    The purpose of this study was to investigate the behavior of concrete columns reinforced by Welded Wire Fabric, WWF, as transverse reinforcement under concentric loading and to compare the results with concrete columns reinforced by round bar as tie reinforcement when the volumetric ratio of transverse reinforcement was equal. Additionally, the effect of the spacing of transverse tie reinforcement on strength and ductility of the columns was studied by testing six different types of column sp...

  14. Evaluation of different column chemistries for fast urinary metabolic profiling.

    Science.gov (United States)

    Kloos, Dick-Paul; Lingeman, Henk; Niessen, Wilfried M A; Deelder, André M; Giera, Martin; Mayboroda, Oleg A

    2013-05-15

    Fast analytical methodologies are mandatory for large scale metabolic profiling. Here, we present a thorough evaluation of different column chemistries in combination with different mobile phases for fast LC-MS urinary metabolic profiling. Three porous HILIC materials were investigated, next to core-shell C18-, XB-C18- and PFP-RPLC material. The performance of the selected column chemistries was tested in a non-targeted manner with pooled urine samples and in a targeted manner with a set of 54 common urinary metabolites. In order to evaluate the differential behaviour of the tested columns in a targeted manner, we applied a peak scoring algorithm. This algorithm takes into account several quality criteria such as retention time, dead time, peak height and peak shape. In general, HILIC columns generate more retention for polar metabolites. Our results show that the diol-HILIC column outperforms the RPLC columns. However, because of their opposite nature, comprehensive behaviour is observed as well, which was shown by investigating gender differences in a small urinary sample set. All applied column chemistries enabled sufficient peak capacity within a short gradient time. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Hydrodynamic Study Of Column Bioleaching Processes

    Directory of Open Access Journals (Sweden)

    Sadowski Zygmunt

    2015-06-01

    Full Text Available The modelling of flow leaching solution through the porous media has been considered. The heap bioleaching process can be tested using the column experimental equipment. This equipment was employed to the hydrodynamic studies of copper ore bioleaching. The copper ore (black shale ore with the support, inertial materials (glass small balls and polyethylene beads was used to the bioleaching tests. The packed beds were various composition, the ore/support ratio was changed. The correlation between the bed porosity and bioleaching kinetics, and copper recovery was investigated.

  16. Numerical Simulation of Fluid Dynamics in a Monolithic Column

    Directory of Open Access Journals (Sweden)

    Kazuhiro Yamamoto

    2017-01-01

    Full Text Available As for the measurement of polycyclic aromatic hydrocarbons (PAHs, ultra-performance liquid chromatography (UPLC is used for PAH identification and densitometry. However, when a solvent containing a substance to be identified passes through a column of UPLC, a dedicated high-pressure-proof device is required. Recently, a liquid chromatography instrument using a monolithic column technology has been proposed to reduce the pressure of UPLC. The present study tested five types of monolithic columns produced in experiments. To simulate the flow field, the lattice Boltzmann method (LBM was used. The velocity profile was discussed to decrease the pressure drop in the ultra-performance liquid chromatography (UPLC system.

  17. Finite Element Modelling of Cold Formed Stainless Steel Columns

    Directory of Open Access Journals (Sweden)

    M. Macdonald

    2005-01-01

    Full Text Available This paper describes the results obtained from a finite element investigation into the load capacity of column members of lipped channel cross-section, cold formed from Type 304 stainless steel, subjected to concentric and eccentric compression loading. The main aims of this investigation were to determine the effects which the non-linearity of the stress-strain behaviour of the material would have on the column behaviour under concentric or eccentric loading. Stress-strain curves derived from tests and design codes are incorporated into non-linear finite element analyses of eccentrically loaded columns and the results obtained are compared with those obtained on the basis of experiments on stainless steel channel columns with the same properties and dimensions. Comparisons of the finite element results and the test results are also made with existing design specifications and conclusions are drawn on the basis of the comparisons. 

  18. Critical factors in displacement ductility assessment of high-strength concrete columns

    Science.gov (United States)

    Taheri, Ali; Moghadam, Abdolreza S.; Tasnimi, Abass Ali

    2017-12-01

    Ductility of high-strength concrete (HSC) columns with rectangular sections was assessed in this study by reviewing experimental data from the available literature. Up to 112 normal weights concrete columns with strength in the range of 50-130 MPa were considered and presented as a database. The data included the results of column testes under axial and reversed lateral loading. Displacement ductility of HSC columns was evaluated in terms of their concrete and reinforcement strengths, bar arrangement, volumetric ratio of transverse reinforcement, and axial loading. The results indicated that the confinement requirements and displacement ductility in HSC columns are more sensitive than those in normal strength concrete columns. Moreover, ductility is descended by increasing concrete strength. However, it was possible to obtain ductile behavior in HSC columns through proper confinement. Furthermore, this study casts doubt about capability of P/ A g f c' ratio that being inversely proportional to displacement ductility of HSC columns.

  19. Evaluation of Seismic Behaviors of Partially Deteriorated Reinforced Concrete Circular Columns Retrofitted with CFRP

    Directory of Open Access Journals (Sweden)

    Dongxu Hou

    2014-01-01

    Full Text Available Deficiency of the concrete strength in some regions of reinforced concrete (RC columns in practice may weaken the seismic behaviors of columns. Its effects on RC columns should be well understood. This paper aims to investigate the influences of deteriorated segment on the seismic behaviors of partially deteriorated RC columns and attempts to recover the seismic behaviors of partially deteriorated columns with Carbon Fiber Reinforced Polymer (CFRP composites. A finite element analysis was carried out to simulate the seismic behaviors of CFRP-confined partially deteriorated RC columns. The numerical results were verified by the laboratory tests of six specimens. Based on the finite element results, the failure location of partially deteriorated columns in an earthquake was predicted, and the effectiveness of CFRP retrofitted on partially deteriorated columns was evaluated.

  20. Critical factors in displacement ductility assessment of high-strength concrete columns

    Science.gov (United States)

    Taheri, Ali; Moghadam, Abdolreza S.; Tasnimi, Abass Ali

    2017-09-01

    Ductility of high-strength concrete (HSC) columns with rectangular sections was assessed in this study by reviewing experimental data from the available literature. Up to 112 normal weights concrete columns with strength in the range of 50-130 MPa were considered and presented as a database. The data included the results of column testes under axial and reversed lateral loading. Displacement ductility of HSC columns was evaluated in terms of their concrete and reinforcement strengths, bar arrangement, volumetric ratio of transverse reinforcement, and axial loading. The results indicated that the confinement requirements and displacement ductility in HSC columns are more sensitive than those in normal strength concrete columns. Moreover, ductility is descended by increasing concrete strength. However, it was possible to obtain ductile behavior in HSC columns through proper confinement. Furthermore, this study casts doubt about capability of P/A g f c' ratio that being inversely proportional to displacement ductility of HSC columns.

  1. Residual Axial Capacity Comparison of CFFT and RC Bridge Columns after Fire

    Directory of Open Access Journals (Sweden)

    Alicia Echevarria

    2015-05-01

    Full Text Available The fire performance of protected concrete-filled fiber reinforced polymer (FRP tube (CFFT and conventional reinforced concrete (RC bridge columns is studied through two phases of experimental research comprised of fire exposure and residual axial capacity tests. Two one-fifth scale CFFT columns and two one-fifth scale conventional RC columns having similar axial and flexural capacities were subjected to two durations of extreme temperature exposure. The CFFT columns were protected by the Tyfo® CFP fire protection system during the experiments. Subsequently, the post-fire robustness of the columns was quantified by measuring the residual axial capacity characteristics of each column. The protected CFFT columns exhibited superior axial strength and stiffness retention compared to the RC columns after fire exposure.

  2. Bubble columns : Structures or stability?

    NARCIS (Netherlands)

    Harteveld, W.K.

    2005-01-01

    The aim of the thesis is to contribute to the understanding of the hydrodynamics of the gravity driven bubbly flow that can be found in bubble columns. Special attention is paid to the large scale structures that have a strong impact on several key parameters such as the degree of mixing, mass and

  3. Editorial/Associate Editor's Column

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 2. Editorial / Associate Editor's Column. Rajaram Nityananda. Editorial Volume 5 Issue 2 February 2000 pp 1-1. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/005/02/0001-0001. Author Affiliations.

  4. THE ELASTO-PLASTIC BEHAVIOR OF THE RC COLUMN ACCOMPANIED WITH FRICTION DAMPING MECHANISM

    Science.gov (United States)

    Nakamura, Hideyuki; Takahashi, Yoshikazu; Sawada, Sumio

    A novel idea of a high seismic-performance RC column which is expected to remain undamaged against strong earthquake motions is presented. A larger elastic deformation capacity can be achieved by dividing vertically a rectangular column into several column components, while friction material interfaces between the column components with horizontal confining forces provide energy dissipation capability to the column. In this study, static loading tests of a test specimen of the proposed RC column are carried out. It is shown that each column is within the elastic range up to 2% drift and the restoring force is fairly constant up to 10% drift in the plastic region. These results show the expected hysteretic behavior in the elastic range and preferable ductile behavior in the plastic deformation range.

  5. A stepwise stoichiometric representation to confirm the dependence of pesticide/humic acid interactions on salt concentration and to test the performance of a silica bonded humic acid column.

    Science.gov (United States)

    André, C; Thomassin, M; Berthelot, A; Guillaume, Y C

    2006-02-01

    In a previous paper (André et al., in press), a novel chromatographic column was developed in our laboratory for studying the binding of pesticides with humic acid (HA), the main organic component in soil. It was demonstrated that this column supported a low fraction of organic modifier in the aqueous mobile phase (equation for the partition of the added salt between the pesticide molecule, the HA, and the pesticide/HA complex. Based on this novel equation, the dependence of the pesticide/humic acid association on the salt concentration can be formulated via a relation similar to the one of Tanford. In addition, for the first time, the calculation of the affinity energy distribution for different values of the salt concentration in the mobile phase confirmed the existence of several types of binding sites on the HA macromolecule.

  6. Modeling of column apparatus processes

    CERN Document Server

    Boyadjiev, Christo; Boyadjiev, Boyan; Popova-Krumova, Petya

    2016-01-01

    This book presents a new approach for the modeling of chemical and interphase mass transfer processes in industrial column apparatuses, using convection-diffusion and average-concentration models. The convection-diffusion type models are used for a qualitative analysis of the processes and to assess the main, small and slight physical effects, and then reject the slight effects. As a result, the process mechanism can be identified. It also introduces average concentration models for quantitative analysis, which use the average values of the velocity and concentration over the cross-sectional area of the column. The new models are used to analyze different processes (simple and complex chemical reactions, absorption, adsorption and catalytic reactions), and make it possible to model the processes of gas purification with sulfur dioxide, which form the basis of several patents.

  7. Completing electron scattering studies with the inert gas column:e - Rn scattering and Ionization

    CERN Document Server

    Joshi, Foram M; Chaudhari, Asha S; Modi, Hitesh S; Pindaria, Manish J

    2016-01-01

    Interest in the inert or noble- gas atoms in general arises because they are ideal as test systems for various theoretical models of electron scattering and also since their interaction processes serve as reference for the determination of instrumental responses in electron scattering experiments. The ionization cross section data of ground state inert gas atoms He through Xe are considered to be benchmark data. Our aim in this paper is to provide theoretical results on electron scattering with Radon atoms, as it would complete the studies on the entire inert gas column. That is possible with this particular column only, in view of the preceding literature on He through Xe . Inert gas radon is radioactive, and would be a difficult target for electron scattering experiments. In the present calculations, the complications arising from radioactivity are not considered. We provide hitherto unavailable cross sections on atomic radon, and also provide opportunity of the comparison of electron impact cross sections ...

  8. Seismic performance of recycled concrete-filled square steel tube columns

    Science.gov (United States)

    Chen, Zongping; Jing, Chenggui; Xu, Jinjun; Zhang, Xianggang

    2017-01-01

    An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.

  9. 40 CFR 799.6786 - TSCA water solubility: Generator column method.

    Science.gov (United States)

    2010-07-01

    ...-366 (1981). (2) Hansch, C. et al., The linear free-energy relationship between partition coefficients... 40 Protection of Environment 31 2010-07-01 2010-07-01 true TSCA water solubility: Generator column... TESTING REQUIREMENTS Product Properties Test Guidelines § 799.6786 TSCA water solubility: Generator column...

  10. Fire response of composite columns subject to sway

    DEFF Research Database (Denmark)

    Virdi, Kuldeep

    the scope of the project which covered control tests under ambient conditions, carried out by the author while at City University London. Other aspects covered in the project included fire tests carried out by CTICM in France, on isolated columns and on two frames designed by Leibniz Universität Hannover...... conditions is adequately covered in the relevant standard, Eurocode 4, simplified design of unbraced composite columns for the fire limit state has not been included. Recognising this, a collaborative research project was undertaken with funding from the Research Fund for Coal and Steel. The paper describes...... as well as extensive numerical studies aimed at developing a design method for sway composite columns exposed to fire....

  11. Axisymmetric collapses of granular columns

    Science.gov (United States)

    Lube, Gert; Huppert, Herbert E.; Sparks, R. Stephen J.; Hallworth, Mark A.

    2004-06-01

    Experimental observations of the collapse of initially vertical columns of small grains are presented. The experiments were performed mainly with dry grains of salt or sand, with some additional experiments using couscous, sugar or rice. Some of the experimental flows were analysed using high-speed video. There are three different flow regimes, dependent on the value of the aspect ratio a {=} h_i/r_i, where h_i and r_i are the initial height and radius of the granular column respectively. The differing forms of flow behaviour are described for each regime. In all cases a central, conically sided region of angle approximately 59(°) , corresponding to an aspect ratio of 1.7, remains undisturbed throughout the motion. The main experimental results for the final extent of the deposit and the time for emplacement are systematically collapsed in a quantitative way independent of any friction coefficients. Along with the kinematic data for the rate of spread of the front of the collapsing column, this is interpreted as indicating that frictional effects between individual grains in the bulk of the moving flow only play a role in the last instant of the flow, as it comes to an abrupt halt. For a {reach r_infty is given by t_infty {=} 3(h_i/g)(1/2} {=} 3(r_i/g)({1/2}a^{1/2)) , where g is the gravitational acceleration. The insights and conclusions gained from these experiments can be applied to a wide range of industrial and natural flows of concentrated particles. For example, the observation of the rapid deposition of the grains can help explain details of the emplacement of pyroclastic flows resulting from the explosive eruption of volcanoes.

  12. Column flotation results at Powell Mountain Coal Company

    Energy Technology Data Exchange (ETDEWEB)

    Peters, W.J.; Parekh, B.K. (Powell Mountain Coal Company (USA))

    1992-01-01

    In 1989 a column flotation process was developed at the CAER, which enabled the economical recovery of coal fines from high-ash fine refuse. The laboratory design was expanded to commercial scale and installed at the Mayflower Coal Preparation Plant of Powell Mountain Coal Company in December, 1989. It has been in continuous operation there since that time. This article is a summary of the past two years' experiences with this applied technology, applicable dewatering tests and flotation tests results from the plant. Conventional froth flotation techniques are ineffective for the recovery of very fine coal. In the 'Ken-Flote' process coal slurry is fed into a flotation column. Coal-laden air bubbles are carried upwards to the cleaning zone where a spray of wash water removes residual mineral matter. Operating experience indicates that column performance depends on e.g. type of frother, percentage solids feed and column froth depth. Many manufacturers in the USA are now installing column flotation concepts and technology, indicating the success of the project. 2 figs.

  13. Towards point of care testing for C. difficile infection by volatile profiling, using the combination of a short multi-capillary gas chromatography column with metal oxide sensor detection.

    Science.gov (United States)

    McGuire, N D; Ewen, R J; de Lacy Costello, B; Garner, C E; Probert, C S J; Vaughan, K; Ratcliffe, N M

    2014-05-12

    Rapid volatile profiling of stool sample headspace was achieved using a combination of short multi-capillary chromatography column (SMCC), highly sensitive heated metal oxide semiconductor (MOS) sensor and artificial neural network (ANN) software. For direct analysis of biological samples this prototype offers alternatives to conventional GC detectors and electronic nose technology. The performance was compared to an identical instrument incorporating a long single capillary column (LSCC). The ability of the prototypes to separate complex mixtures was assessed using gas standards and homogenised in house 'standard' stool samples, with both capable of detecting more than 24 peaks per sample. The elution time was considerably faster with the SMCC resulting in a run time of 10 minutes compared to 30 minutes for the LSCC. The diagnostic potential of the prototypes was assessed using 50 C. difficile positive and 50 negative samples. The prototypes demonstrated similar capability of discriminating between positive and negative samples with sensitivity and specificity of 85% and 80% respectively. C. difficile is an important cause of hospital acquired diarrhoea, with significant morbidity and mortality around the world. A device capable of rapidly diagnosing the disease at the point of care would reduce cases, deaths and financial burden.

  14. Gamma radiation effects on polydimethylsilane stationary phases for use in packed-column gas chromatographic analyses

    Directory of Open Access Journals (Sweden)

    Adaime M.B.

    1999-01-01

    Full Text Available Gamma radiation induced immobilization of several polydimethylsilane liquid stationary phases for use in packed-column gas chromatographic separations has been studied. Extraction tests show that moderate doses of gamma radiation (80-140 kGy are sufficient to produce significant (90% immobilization of most polydimethylsilanes onto Chromosorb supports, although a molecular mass effect is seen. Thermal stability also increases significantly with radiation dose, suggesting higher temperature use with smaller volatility losses. Infrared spectra confirm the continued presence of the stationary phase on the support after thermal stability tests and after exhaustive in-column washing. The column chromatographic behavior of the immobilized phases is equal to or better than that of the unirradiated phases, except for higher doses (300 kGy of gamma-radiation. Columns prepared from gamma-immobilized polydimethylsilane have been used successfully in analyses where column contamination from high boiling materials requires frequent column recuperation.

  15. Experimental analysis of reinforced concrete columns strengthened with Self-Compacting concrete

    Directory of Open Access Journals (Sweden)

    M. Y. M. Omar

    Full Text Available This paper presents the results of reinforced concrete columns strengthened by addition of a self-compacting concrete overlay at the compressed and at the tensioned face of the member, with and without addition of longitudinal steel bars. Eight columns were submit- ted to loading with an initial eccentricity of 60 mm . These columns had 120 mm x 250 mm of rectangular cross section, 2000 mm in length and four longitudinal reinforcement steel bars with 10 mm in diameter. Reference columns P1 and P2 were tested to failure without any type of rehabilitation. Columns P3 to P8 were loaded to a predefined load (close to the initial yield point of tension reinforce- ment, then unloaded and strengthened for a subsequent test until failure. Results showed that the method of rehabilitation used was effective, increasing the loading capacity of the strengthened pieces by 2 to 5 times the ultimate load of the reference column.

  16. Development of gamma column scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee; Jun, Jong Kyu; Kim, Jin Sup

    2004-11-01

    Distillation column is important unit in petro-chemical industries, and its on-line diagnose is important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose to find out missing tray or flooding. In many cases the distance from radiation detector to detection circuit is up to 100m long. Conventional radiation detection method that is to transmit analog signal by co axial cable directly to detection circuit couldn't give good result because of its long cable. In this case the system is sensitive to electric noise because of long cable and interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using digital modulated signal and loop coil to transmit signal instead of slip ring and analog signal. In detail detection part of automatic gamma scanner consists of high voltage circuit, PHA circuit FSK modem and battery. This method isolates power system and gives good solution for automatic gamma scanning by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  17. Experimental Verification of the Structural Glass Beam-Columns Strength

    Science.gov (United States)

    Pešek, Ondřej; Melcher, Jindřich; Balázs, Ivan

    2017-10-01

    This paper deals with experimental research of axially and laterally loaded members made of structural (laminated) glass. The purpose of the research is the evaluation of buckling strength and actual behaviour of the beam-columns due to absence of standards for design of glass load-bearing structures. The experimental research follows the previous one focusing on measuring of initial geometrical imperfections of glass members, testing of glass beams and columns. Within the frame of the research 9 specimens were tested. All of them were of the same geometry (length 2000 mm, width 200 mm and thickness 16 mm) but different composition – laminated double glass made of annealed glass or fully tempered glass panes bonded together by PVB or EVASAFE foil. Specimens were at first loaded by axial force and then by constantly increasing bending moment up to failure. During testing lateral deflections, vertical deflection and normal stresses at mid-span were measured. A maximum load achieved during testing has been adopted as flexural-lateral-torsional buckling strength. The results of experiments were statistically evaluated according to the European standard for design of structures EN 1990, appendix D. There are significant differences between specimens made of annealed glass or fully tempered glass. Differences between specimens loaded by axial forces 1 kN and 2 kN are negligible. The next step was to determine the design strength by calculation procedure based on buckling curves approach intended for design of steel columns and develop interaction criterion for glass beams-columns.

  18. Pressure Control in Distillation Columns: A Model-Based Analysis

    DEFF Research Database (Denmark)

    Mauricio Iglesias, Miguel; Bisgaard, Thomas; Kristensen, Henrik

    2014-01-01

    A comprehensive assessment of pressure control in distillation columns is presented, including the consequences for composition control and energy consumption. Two types of representative control structures are modeled, analyzed, and benchmarked. A detailed simulation test, based on a real...... industrial distillation column, is used to assess the differences between the two control structures and to demonstrate the benefits of pressure control in the operation. In the second part of the article, a thermodynamic analysis is carried out to establish the influence of pressure on relative volatility...

  19. Stud Reinforcement in Beam-Column Joints under Seismic Loads

    Science.gov (United States)

    Ibrahim, Hatem Hassan Ali

    Current codes recommend large amounts of shear reinforcement for reinforced concrete beam-column joints causing significant congestion. This research aims at investigating experimentally and numerically the efficiency of using studs with a head at each end in lieu of conventional closed hoops in reinforced concrete beam-column joints. The proposed reinforcement reduces congestion and ensures easier assembly of the reinforcing cage, saving labour cost and enhancing performance of the joint. Based on this research, a recommended arrangement and detailing of headed studs and their design for exterior beam-column joint are presented. The experimental investigation consisted of testing ten full-scale beam-column joint specimens under quasi-static cyclic loading. The specimens represented an exterior beam-column joint subassembly isolated at the points of contra-flexure from a typical multi-storey, multi-bay reinforced concrete frame. A test setup was developed to simulate the lateral inter-storey drift. The test parameters included: the type, arrangement and amount of shear reinforcement, the load history and rate of loading, and the amount of reinforcement for out-of-plane confinement of the joint. Envelopes of the hysteretic behaviour of the specimens and the joint deformation under shear stress are presented. The stiffness degradation, the strain levels in the joint reinforcement, the contribution of joint, beam, and column to the inter-storey drift, and the energy dissipation were compared. All the test specimens reinforced with headed studs in the joint achieved considerable enhancement in their behaviour under cyclic loads and exhibited a performance close to that of a joint reinforced with closed hoops and cross ties according to the code. All the specimens with adequate out-of-plane confinement had an equivalent behaviour compared with the code-based specimen and achieved a desirable mode of failure. Use of double-headed studs proved to be a viable option for

  20. Contaminated marine sediments: Water column and interstitial toxic effects

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, R.M.; Schweitzer, K.A.; McKinney, R.A.; Phelps, D.K.

    1993-01-01

    The toxicity that contaminated sediments may introduce into the water column has not been measured extensively. In order to quantify this potential toxicity, the seawater overlying two uncontaminated and three contaminated marine sediments was evaluated in the laboratory with the sea urchin Arbacia punctulata fertilization test. Concentrations of polychlorinated biphenyls (PCBs) and copper, as representative contaminants, were also measured. To characterize sources of toxicity, samples were chemically manipulated using reversed-phase chromatography, cation exchange, and chelation. Water column toxicity and contaminant concentrations were higher in the suspended exposures than in bedded exposures. Interstitial water toxicity and contaminant concentrations were generally greater than either bedded or suspended exposures. Chemical manipulation indicated that the observed toxicity in water column exposures was probably caused by metallic and/or nonionic organic contaminants. Conversely, manipulation of interstitial waters did not result in significantly reduced toxicity, suggesting that other toxicants such as ammonia and hydrogen sulfide may be active.

  1. Contaminated marine sediments: Water column and interstitial toxic effects

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, R.M.; McKinney, R.A. (Science Applications International Corp., Narragansett, RI (United States)); Schweitzer, K.A. (Chemical Waste Management, Inc., Dartmouth, MA (United States)); Phelps, D.K. (Environmental Protection Agency, Narragansett, RI (United States))

    1993-01-01

    The toxicity that contaminated sediments may introduce into the water column has not been measured extensively. In order to quantify this potential toxicity, the seawater overlying two uncontaminated and three contaminated marine sediments was evaluated in the laboratory with the sea urchin Arbacia punctulata fertilization test. Concentration of polychlorinated biphenyls (PCBs) and copper, as representative contaminants, were also measured. To characterize sources of toxicity, samples were chemically manipulated using reversed-phase chromatography, cation exchange, and chelation. Water column toxicity and contaminant concentrations were higher in the suspended exposures than in bedded exposures. Interstitial water toxicity and contaminant concentrations were generally greater than either bedded or suspended exposures. Chemical manipulation indicated that the observed toxicity in water column exposures was probably caused by metallic and/or nonionic organic contaminants. Conversely, manipulation of interstitial water did not result in significantly reduced toxicity, suggesting that other toxicants such as ammonia and hydrogen sulfide may be active.

  2. Oscillating water column structural model

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, Guild [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bull, Diana L [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jepsen, Richard Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gordon, Margaret Ellen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    An oscillating water column (OWC) wave energy converter is a structure with an opening to the ocean below the free surface, i.e. a structure with a moonpool. Two structural models for a non-axisymmetric terminator design OWC, the Backward Bent Duct Buoy (BBDB) are discussed in this report. The results of this structural model design study are intended to inform experiments and modeling underway in support of the U.S. Department of Energy (DOE) initiated Reference Model Project (RMP). A detailed design developed by Re Vision Consulting used stiffeners and girders to stabilize the structure against the hydrostatic loads experienced by a BBDB device. Additional support plates were added to this structure to account for loads arising from the mooring line attachment points. A simplified structure was designed in a modular fashion. This simplified design allows easy alterations to the buoyancy chambers and uncomplicated analysis of resulting changes in buoyancy.

  3. Experimental analysis of reinforcing columns of reinforced concrete, with anchor steel bolts

    Directory of Open Access Journals (Sweden)

    A. C. MESQUITA

    Full Text Available Abstract This article presents a columns reinforcement experimental study, with the use of anchor steel bolts and fill with self-compacting concrete. Were tested five columns of reinforced concrete subjected to flexion-compression: two columns were used as reference, and a cross-section equal to 120 x 250 mm; with a monolithic section equal to 155 x 250 mm cross section of the same reinforced columns and three which were initially molded with a 120 x 250 mm section and subsequently received a layer of 35 mm thick self-compacting concrete in the compressed side. Despite the studs do not present break, there was peeling of the reinforcement layer. The results indicate the possibility of using this method in reinforcing structural rehabilitation of reinforced concrete columns, with increase in load capacity on average equal to 403% in relation to the column reference.

  4. Applications of monolithic columns in liquid chromatography-based clinical chemistry assays.

    Science.gov (United States)

    Bunch, Dustin R; Wang, Sihe

    2011-08-01

    Monolithic columns have slowly been applied to HPLC methods for clinical chemistry testing in the last 10 years. The application areas include therapeutic drug monitoring, drugs of abuse, vitamins, porphyrins, and steroids. In comparison with conventional particulate columns, the monolithic columns may offer shorter chromatography time, more robustness, and better resolution for certain analytes. The potential drawback of large mobile phase consumption may be improved with smaller id columns, which are currently on the market. Methods covered in this review are those searchable in PubMed up to December 2010. This review highlights the emergence of monolithic column technology in HPLC methods used for clinical chemistry testing. The goals of this review are threefold: (i) To identify the areas of clinical chemistry that analytical monolithic columns have been used in HPLC methods. (ii) To demonstrate the application of analytical monolithic columns in HPLC methods using different detection systems. (iii) To discuss the advantages and limitations of the monolithic columns compared with particulate columns in the clinical chemistry applications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Failure Investigation of Debonded Sandwich Columns: An Experimental and Numerical Study

    DEFF Research Database (Denmark)

    Moslemian, Ramin; Berggreen, Christian; Carlsson, Leif A.

    2009-01-01

    Failure of compression loaded sandwich columns with an implanted through-width face/core debond is examined. Compression tests were conducted on sandwich columns containing implemented face/core debonds. The strains and out-of-plane displacements of the debonded region were monitored using the di...

  6. SPR Hydrostatic Column Model Verification and Validation.

    Energy Technology Data Exchange (ETDEWEB)

    Bettin, Giorgia [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lord, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rudeen, David Keith [Gram, Inc. Albuquerque, NM (United States)

    2015-10-01

    A Hydrostatic Column Model (HCM) was developed to help differentiate between normal "tight" well behavior and small-leak behavior under nitrogen for testing the pressure integrity of crude oil storage wells at the U.S. Strategic Petroleum Reserve. This effort was motivated by steady, yet distinct, pressure behavior of a series of Big Hill caverns that have been placed under nitrogen for extended period of time. This report describes the HCM model, its functional requirements, the model structure and the verification and validation process. Different modes of operation are also described, which illustrate how the software can be used to model extended nitrogen monitoring and Mechanical Integrity Tests by predicting wellhead pressures along with nitrogen interface movements. Model verification has shown that the program runs correctly and it is implemented as intended. The cavern BH101 long term nitrogen test was used to validate the model which showed very good agreement with measured data. This supports the claim that the model is, in fact, capturing the relevant physical phenomena and can be used to make accurate predictions of both wellhead pressure and interface movements.

  7. Differential column measurements using compact solar-tracking spectrometers

    Science.gov (United States)

    Chen, Jia; Viatte, Camille; Hedelius, Jacob K.; Jones, Taylor; Franklin, Jonathan E.; Parker, Harrison; Gottlieb, Elaine W.; Wennberg, Paul O.; Dubey, Manvendra K.; Wofsy, Steven C.

    2016-07-01

    We demonstrate the use of compact solar-tracking Fourier transform spectrometers (Bruker EM27/SUN) for differential measurements of the column-averaged dry-air mole fractions of CH4 and CO2 within urban areas. Using Allan variance analysis, we show that the differential column measurement has a precision of 0.01 % for XCO2 and XCH4 with an optimum integration time of 10 min, corresponding to Allan deviations of 0.04 ppm and 0.2 ppb, respectively. The sensor system is very stable over time and after relocation across the continent. We report tests of the differential column measurement, and its sensitivity to emission sources, by measuring the downwind-minus-upwind column difference ΔXCH4 across dairy farms in the Chino area, California, and using the data to verify emissions reported in the literature. Ratios of spatial column differences ΔXCH4/ΔXCO2 were observed across Pasadena within the Los Angeles basin, indicating values consistent with regional emission ratios from the literature. Our precise, rapid measurements allow us to determine significant short-term variations (5-10 min) of XCO2 and XCH4 and to show that they represent atmospheric phenomena.Overall, this study helps establish a range of new applications for compact solar-viewing Fourier transform spectrometers. By accurately measuring the small differences in integrated column amounts across local and regional sources, we directly observe the mass loading of the atmosphere due to the influence of emissions in the intervening locale. The inference of the source strength is much more direct than inversion modeling using only surface concentrations and less subject to errors associated with small-scale transport phenomena.

  8. Column: Factors Affecting Data Decay

    Directory of Open Access Journals (Sweden)

    Kevin Fairbanks

    2012-06-01

    Full Text Available In nuclear physics, the phrase decay rate is used to denote the rate that atoms and other particles spontaneously decompose. Uranium-235 famously decays into a variety of daughter isotopes including Thorium and Neptunium, which themselves decay to others. Decay rates are widely observed and wildly different depending on many factors, both internal and external. U-235 has a half-life of 703,800,000 years, for example, while free neutrons have a half-life of 611 seconds and neutrons in an atomic nucleus are stable.We posit that data in computer systems also experiences some kind of statistical decay process and thus also has a discernible decay rate. Like atomic decay, data decay fluctuates wildly. But unlike atomic decay, data decay rates are the result of so many different interplaying processes that we currently do not understand them well enough to come up with quantifiable numbers. Nevertheless, we believe that it is useful to discuss some of the factors that impact the data decay rate, for these factors frequently determine whether useful data about a subject can be recovered by forensic investigation.(see PDF for full column

  9. Behaviour of axially and eccentrically loaded short columns reinforced with GFRP bars

    Science.gov (United States)

    Sreenath, S.; Balaji, S.; Saravana Raja Mohan, K.

    2017-07-01

    The corrosion of steel reinforcing bars is a predominant factor in limiting the life expectancy of Reinforced Cement Concrete (RCC) structures. Corrosion resistant Fibre Reinforced Polymer (FRP) bars can be an effective alternative to steel bars in this context. Recent investigations reported the flexural behaviour of RCC beams reinforced with Glass Fibre Reinforced Polymer (GFRP) bars. This study is meant to investigate the suitability of Sand Coated GFRP reinforcement bars in short square columns which when loaded axially and loaded with a minimum eccentricity. Standard tests to assess mechanical properties of GFRP bars and pullout test to quantify the bond strength between the bars and concrete were conducted. GFRP reinforced column specimens with a cross-sectional dimension of 100mm X 100mm and of length 1000mm were cast and tested under axial and eccentric loading. The assessed load carrying capacity was compared with that of conventional steel reinforced columns of the same size. The yield load and ultimate load at failure withstood by the steel reinforced columns were considerably more than that of GFRP reinforced columns. The energy absorption capacity of GFRP reinforced columns was also poor compared to steel reinforced columns. Both the columns exhibited nearly the same ductile behaviour. Hence GFRP reinforcements are not recommendable for compression members.

  10. Dynamic Effects of Diabatization in Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2012-01-01

    The dynamic eects of diabatization in distillation columns are investigated in simulation with primary focus on the heat-integrated distillation column (HIDiC). A generic, dynamic, rst-principle model has been formulated, which is exible to describe various diabatic distillation congurations. Dyn...

  11. Deformation Monitoring of Retrofitted Short Concrete Columns with Laser Sensor

    Science.gov (United States)

    Avsar, E. Ö.; Celik, M. F.; Binbir, E.; Arslan, A. E.; Çokkeçeci, D.; Seker, D. Z.; Pala, S.

    2016-06-01

    This paper presents one of the applications of monitoring mechanical tests carried out in Construction Materials Laboratory of Istanbul Technical University. In Turkey, as in many countries, large amount of existing buildings exposed to seismic hazard, therefore various analytical and experimental studies are being conducted to contribute to the solution of the problem. One of the new generation retrofitting techniques is to strength the structural members by using Fiber Reinforcing Polymer (FRP). This study summarize the results of monitoring of deformations short concrete column samples under the incremental compression load. In this study, result of two rectangular short columns are given. One of them was tested as a reference sample, the other sample were tested after strengthening by PET reinforced polymer composite materials. Besides conventional displacement and strain measurement systems, laser scanning method was used to get three dimensional deformed shape of sample at each selected steps.

  12. Water Column Exploration Field Trial I (EX0904, EM302) aboard the NOAA Ship Okeanos Explorer in the Gorda Ridge, off the coasts of Oregon and California

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This cruise is a water column exploration field trial cruise, designed to test and refine operations for conducting water column exploration using NOAA Ship Okeanos...

  13. Naphthyl methacrylate-based monolithic column for RP-CEC via hydrophobic and pi interactions.

    Science.gov (United States)

    Karenga, Samuel; El Rassi, Ziad

    2010-03-01

    A neutral naphthyl methacrylate-based monolith (NMM) was introduced for RP-CEC of various aromatic compounds via hydrophobic and pi interactions. It was characterized over a wide range of elution conditions to gain insight into its RP retention mechanism toward the various solute probes under investigation. First, the NMM column exhibited cathodal EOF at various mobile phase compositions and pH suggesting that although the NMM column is void of fixed charges, it acquires a negative zeta potential. It is believed that the negative zeta potential is imparted by the adsorption of mobile phase ions to the NMM surface. The NMM column exhibited pi-pi interactions in addition to hydrophobic interactions due to the aromatic and nonpolar nature of its naphthyl ligands. In all cases, the retention of the various aromatic test solutes including PAHs, benzene derivatives, toluene derivatives, anilines and toluidine, tolunitrile and nitrotoluene positional isomers on the NMM column were compared to their retention on an octadecyl acrylate-based monolithic column. Not only were the values of the retention factors of the various solutes on the NMM column higher than those obtained on the octadecyl acrylate-based monolithic column under otherwise the same CEC conditions, but the elution orders were also different on both columns with a superior and unique selectivity exhibited by the NMM column.

  14. Numerical Study of Damage Modes and Damage Assessment of CFST Columns under Blast Loading

    Directory of Open Access Journals (Sweden)

    Junhao Zhang

    2016-01-01

    Full Text Available Columns of frame structures are the key load-bearing components and the exterior columns are susceptible to attack in terrorist blasts. When subjected to blast loads, the columns would suffer a loss of bearing capacity to a certain extent due to the damage imparted, which may induce the collapse of them and even cause the progressive collapse of the whole structure. In this paper, the high-fidelity physics-based finite element program LS-DYNA was utilized to investigate the dynamic behavior and damage characteristics of the widely used concrete-filled steel tube (CFST columns subjected to blast loads. The established numerical model was calibrated with test data in open literatures. Possible damage modes of CFST columns under blast loading were analyzed, and the damage criterion based on the residual axial load capacity of the columns was adopted to assess the damage degree. A parametric study was conducted to investigate the effects of critical parameters such as blast conditions and column details on the damage degree of CFST columns. Based on the numerical simulation data, an empirical equation was proposed to estimate the variation of columns damage degree with the various parameters.

  15. 16S rRNA gene survey of microbial communities in Winogradsky columns.

    Directory of Open Access Journals (Sweden)

    Ethan A Rundell

    Full Text Available A Winogradsky column is a clear glass or plastic column filled with enriched sediment. Over time, microbial communities in the sediment grow in a stratified ecosystem with an oxic top layer and anoxic sub-surface layers. Winogradsky columns have been used extensively to demonstrate microbial nutrient cycling and metabolic diversity in undergraduate microbiology labs. In this study, we used high-throughput 16s rRNA gene sequencing to investigate the microbial diversity of Winogradsky columns. Specifically, we tested the impact of sediment source, supplemental cellulose source, and depth within the column, on microbial community structure. We found that the Winogradsky columns were highly diverse communities but are dominated by three phyla: Proteobacteria, Bacteroidetes, and Firmicutes. The community is structured by a founding population dependent on the source of sediment used to prepare the columns and is differentiated by depth within the column. Numerous biomarkers were identified distinguishing sample depth, including Cyanobacteria, Alphaproteobacteria, and Betaproteobacteria as biomarkers of the soil-water interface, and Clostridia as a biomarker of the deepest depth. Supplemental cellulose source impacted community structure but less strongly than depth and sediment source. In columns dominated by Firmicutes, the family Peptococcaceae was the most abundant sulfate reducer, while in columns abundant in Proteobacteria, several Deltaproteobacteria families, including Desulfobacteraceae, were found, showing that different taxonomic groups carry out sulfur cycling in different columns. This study brings this historical method for enrichment culture of chemolithotrophs and other soil bacteria into the modern era of microbiology and demonstrates the potential of the Winogradsky column as a model system for investigating the effect of environmental variables on soil microbial communities.

  16. Temperature of Steel Columns under Natural Fire

    Directory of Open Access Journals (Sweden)

    F. Wald

    2004-01-01

    Full Text Available Current fire design models for time-temperature development within structural elements as well as for structural behaviour are based on isolated member tests subjected to standard fire regimes, which serve as a reference heating, but do not model natural fire. Only tests on a real structure under a natural fire can evaluate future models of the temperature developments in a fire compartment, of the transfer of heat into the structure and of the overall structural behaviour under fire.To study overall structural behaviour, a research project was conducted on an eight storey steel frame building at the  Cardington Building Research Establishment laboratory on January 16, 2003. A fire compartment 11×7 m was prepared on the fourth floor. A fire load of 40 kg/m2 was applied with 100 % permanent mechanical load and 65 % of imposed load. The paper summarises the experimental programme and shows the temperature development of the gas in the fire compartment and of the fire protected columns bearing the unprotected floors.

  17. Development and design of a multi-column experimental setup for Kr/Xe separation

    Energy Technology Data Exchange (ETDEWEB)

    Garn, Troy G. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Greenhalgh, Mitchell [Idaho National Lab. (INL), Idaho Falls, ID (United States); Watson, Tony [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-12-01

    As a precursor to FY-15 Kr/Xe separation testing, design modifications to an existing experimental setup are warranted. The modifications would allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents prepared using an INL patented process. A new cooling apparatus capable of achieving test temperatures to -40° C and able to house a newly designed Xe column was acquired. Modifications to the existing setup are being installed to allow for multi-column testing and gas constituent analyses using evacuated sample bombs. The new modifications will allow for independent temperature control for each column enabling a plethora of test conditions to be implemented. Sample analyses will be used to evaluate the Xe/Kr selectivity of the AgZ-PAN sorbent and determine the Kr purity of the effluent stream following Kr capture using the HZ-PAN sorbent.

  18. Learning mechanism for column formation in the olfactory bulb

    Directory of Open Access Journals (Sweden)

    M. Migliore

    2007-12-01

    Full Text Available Sensory discrimination requires distributed arrays of processing units. In the olfactory bulb, the processing units for odor discrimination are believed to involve dendrodendritic synaptic interactions between mitral and granule cells. There is increasing anatomical evidence that these cells are organized in columns, and that the columns processing a given odor are arranged in widely distributed arrays. Experimental evidence is lacking on the underlying learning mechanisms for how these columns and arrays are formed. To gain insight into these mechanisms, we have used a simplified realistic circuit model to test the hypothesis that distributed connectivity can self-organize through an activity-dependent dendrodendritic synaptic mechanism. The results point to action potentials propagating in the mitral cell lateral dendrites as playing a critical role in this mechanism. The model predicts that columns emerge from the interaction between the local temporal dynamics of the action potentials and the synapses that they activate during dendritic propagation. The results suggest a novel and robust learning mechanism for the development of distributed processing units in a cortical structure.

  19. Collapse of tall granular columns in fluid

    Science.gov (United States)

    Kumar, Krishna; Soga, Kenichi; Delenne, Jean-Yves

    2017-06-01

    Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  20. Numerical Evaluation on the Different Shapes of Gravelly Sand Columns to Increase the Loading Capacity of Soft Clay

    Directory of Open Access Journals (Sweden)

    Meghzili Sif Allah

    2017-01-01

    Full Text Available Improvement on soft clay by the installation of stone column is one of the most popular methods followed worldwide. Different analytical and numerical solutions have already been developed for understanding the load transfer mechanism of soft soil reinforced with stone column. This study investigated a bearing capacity of the gravelly sand column, installed in soft clay bed at 15kpa of undrained shear strength. The column variable of length and diameter ratio at 7, 8 and 9 were evaluated. On top of that, the combination of two diameters in single column was tested and the uniform diameter was used as a control. In the numerical analysis, Mohrcoulomb model was adopted in the idealization of the behaviour of the gravelly sand column and soft clay materials. The results revealed that the optimum design that gave the highest loading capacity of the combination 11=12 of column diameter was the length and diameter ratio of 8.

  1. Dynamic effects of diabatization in distillation columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    The dynamic effects of diabatization in distillation columns are investigated in simulation emphasizing the heat-integrated distillation column (HIDiC). A generic, dynamic, first-principle model has been formulated, which is flexible enough to describe various diabatic distillation configurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found and control...

  2. Ductility of reinforced lightweight concrete beams and columns

    OpenAIRE

    Charif, Abdelhamid; Shannag, M. Jamal; Dghaither,Saleh

    2014-01-01

    This paper presents analytical and experimental results on ductility of reinforced lightweight concrete beams and columns in the form of moment curvature relationships, and compares the response with that of normal reinforced concrete members. The experimental part is limited to flexural tests on beams made of lightweight concrete. The latter is obtained with natural lightweight aggregates. Concrete and steel stress-strain models in compression and tension are integrated analytically through ...

  3. Analysis of the behavior of reinforced concrete columns strengthened with sleeve wedge bolts and a self compacting concrete layer

    Directory of Open Access Journals (Sweden)

    M. G. Marques

    Full Text Available Strengthening of reinforced concrete columns by jacketing is one of the most common structural rehabilitation techniques in Brazil. For adequate performance, it is necessary, among others, to avoid detachment of the new concrete layer (strengthening material from the old concrete substrate when the strengthened member is again in service conditions. This paper describes the test results of eight reinforced concrete rectangular columns subjected to combined compression and one-axis bending to evaluate the efficiency of using sleeve wedge bolts across the new concrete/old concrete interface to avoid detachment. The strengthening technique, in this case, consists of adding a layer of self-compacting concrete to one face of the column. Two columns tested were monolithic and named PO (original column e PR (reference column. The other six columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and its results gave information about column behavior without the use of strengthening. Column PR had a 155mm by 250 mm rectangular cross section and its cross section dimensions matched the strengthened columns but it was cast monolithically. To improve bond conditions between the existing concrete and the new concrete, the concrete surface was roughened and the outermost aggregate was exposed using hydro jetting. Holes along the concrete surface were made to insert the wedge bolts responsible for increasing the bond between the two concrete surfaces. The difference among the six strengthened columns was the position and amount of bolts used. Results indicate that the position and amount of the bolts alters significantly the strength capacity of the columns, since premature rupture by concrete detachment was delayed.

  4. Experimental Investigation of Concrete Filled PVC Tube Columns Confined By Plain PVC Socket

    Directory of Open Access Journals (Sweden)

    Jamaluddin N.

    2017-01-01

    Full Text Available This paper presents results of an experimental study for concrete column filled poly vinyl chloride (PVC tubes confined by plain socket with 5.8 & 6.8 mm thicknesses, 102 mm diameter and 100 mm depth. The total of five concrete filled columns using PVC tubes (CFT PVC was tested to investigate the columns’ behaviour. The column is 700 mm height, 100 mm external diameter and 3.5 mm tube thickness with different thickness of plain socket. The results presented include maximum axial load, plain socket confinement effect, the mode of failure, and lateral PVC strain. The axial load enhancement of PVC-concrete columns confined using plain socket shows an increment of 21.3% up to 55.2% and axial strain from 21% to 40% compared with displacement for control composite columns at 192 kN ultimate load.

  5. The Sports Column on National Daily Newspapers

    Directory of Open Access Journals (Sweden)

    Alp Çelik

    2015-10-01

    Full Text Available National daily newspapers aim to report detailed daily news. Sport pages of the newspapers contain sport columns and news about sport activities. The aim of this research was to investigate the sport columns appearing on sport pages of national daily newspapers published in Turkey. During the research process, nine national daily newspapers published in Turkey were reviewed for one year. The number of sport columns, publishing page, publishing space in cm. and accessibility of newspapers are ascertained. Newspaper field measurement, statistical and percentage calculations are made by Microsoft Excel. The study was completed with the transfer of the data obtained from Excel to Word as a document. According to the obtained data, regarding the news density on sport columns; Milliyet has the most news published, Cumhuriyet has the most news on front page, Haber Turk has the most space allocated and Zaman has been the most accessible newspaper.

  6. Unbonded Prestressed Columns for Earthquake Resistance

    Science.gov (United States)

    2012-05-01

    Modern structures are able to survive significant shaking caused by earthquakes. By implementing unbonded post-tensioned tendons in bridge columns, the damage caused by an earthquake can be significantly lower than that of a standard reinforced concr...

  7. Nonlinear control of high purity distillation columns

    OpenAIRE

    Groebel, Markus; Allgöwer, Frank; Storz, Markus; Gilles, Ernst Dieter

    1994-01-01

    Two simple models of distillation columns are studied to investigate their suitability for the practical use with exact I/O-linearization. An extension of exact I/O-linearization, the asymptotically exact I/O-linearization is applied to the control of a high purity distillation column, using one of these models to derive the static state feedback law. Simulation studies demonstrate the advantage of asymptotically exact I/O-linearization versus classical exact I/O-linearization techniques. Exp...

  8. Behavior of reinforced concrete short columns exposed to fire

    National Research Council Canada - National Science Library

    Mohamed Bikhiet, M; El-Shafey, Nasser F; El-Hashimy, Hany M

    2014-01-01

    Fire could dramatically reduce strength of reinforced concrete columns. The objective of this work is to study columns exposed to fire under axial load and to evaluate reduction in column compressive capacity after fire...

  9. Investigation of Limit States Specified for Reinforced Concrete Column Members in TEC–2007

    Directory of Open Access Journals (Sweden)

    Umut HASGÜL

    2016-01-01

    Full Text Available In this study, the deformation based limit states stipulated for reinforced concrete members in the Turkish Earthquake Code (TEC were experimentally investigated. Thus four RC cantilever columns which have low concrete compressive strengths and have not adequate confinement, were subjected to constant axial load and cyclic lateral load history. In the study, firstly, the strain values representing the damage limits were converted to top of the column lateral displacements by using fundamentals of structural mechanics. Subsequently the column damages corresponding to the displacement demands were observed, hence limit states were evaluated. After conducting all column tests, it was noted that no column damage was observed for the immediate occupancy (IO performance level defined in the code. For the life safety (LS and collapse prevention (CP performance levels, though somewhat residual deformations occurred on the critical regions, the column members can pretty much sustain their lateral load capacities. It was also observed for all columns that significant damages and strength losses occurred beyond the collapse prevention level. The results of experimental study indicate that the evaluation procedure in the TEC is still in good relationship with the limit states even if the columns have not adequate compressive strength and confinement.

  10. Comparison of twin-cell centrifugal partition chromatographic columns with different cell volume.

    Science.gov (United States)

    Goll, Johannes; Audo, Gregoire; Minceva, Mirjana

    2015-08-07

    Two twin-cell centrifugal partition chromatographic columns (SCPC 250 and SCPE-250-BIO, Armen Instrument, France) with the same column volume but different cell size and number were compared in terms of stationary phase retention and column efficiency. The columns were tested with two types of solvent systems: a commonly used organic solvent based biphasic system from the ARIZONA solvent system family and a polymer/salt based aqueous two phase system (ATPS). The efficiency of the columns was evaluated by pulse injection experiments of two benzenediols (pyrocatechol and hydroquinone) in the case of the ARIZONA system and a protein mixture (myoglobin and lysozyme) in the case of the ATPS. As result of high stationary phase retention, the column with the lower number of larger twin-cells (SCPE-250-BIO) is suitable for protein separations using ATPS. On the other hand, due to higher column efficiency, the column with the greater number of smaller cells (SCPC 250) is superior for batch elution separations performed with standard liquid-liquid chromatography organic solvent based biphasic systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Quality improvements of cell membrane chromatographic column.

    Science.gov (United States)

    Ding, Xuan; Chen, Xiaofei; Cao, Yan; Jia, Dan; Wang, Dongyao; Zhu, Zhenyu; Zhang, Juping; Hong, Zhanying; Chai, Yifeng

    2014-09-12

    Cell Membrane Chromatography (CMC) is a biological affinity chromatographic method using a silica stationary phase covered with specific cell membrane. However, its short life span and poor quality control was highlighted in a lot of research articles. In this study, special attention has been paid to the disruption, cell load and packing procedure in order to improve the quality of the CMC columns. Hereto, two newly established CMC models, HSC-T6/CMC and SMMC-7721/CMC have been developed and used in this research project. The optimization of the abovementioned parameters resulted in a better reproducibility of the retention time of the compound GFT (RSDCMC columns. 3.5×10(7)cells were the optimal cell load for the preparation of the CMC columns, the disruption condition was optimized to 5 cycles (400W and 20s interval per cycle) by an ultrasonic processor reducing the total time of cell disruption to 1.5min and the packing flow rate was optimized by applying a linear gradient program. Additionally, 4% paraformaldehyde (PFA) was employed to improve the column quality and prolong the column life span. The results showed that the retention time was longer with PFA treated columns than the ones obtained with the control groups. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Structural Decoupling and Disturbance Rejection in a Distillation Column

    DEFF Research Database (Denmark)

    Bahar, Mehrdad; Jantzen, Jan; Commault, C.

    1996-01-01

    Introduction, distillation column model, input-output decoupling, disturbance rejection, concluding remarks, references.......Introduction, distillation column model, input-output decoupling, disturbance rejection, concluding remarks, references....

  13. Strengthening of defected beam-column joints using CFRP.

    Science.gov (United States)

    Mahmoud, Mohamed H; Afefy, Hamdy M; Kassem, Nesreen M; Fawzy, Tarek M

    2014-01-01

    This paper presents an experimental study for the structural performance of reinforced concrete (RC) exterior beam-column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP). The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered defects include the absence of the transverse reinforcement within the joint core, insufficient bond length for the beam main reinforcement and inadequate spliced implanted column on the joint. Three different strengthening schemes were used to rehabilitate the defected beam-column joints including externally bonded CFRP strips and sheets in addition to near surface mounted (NSM) CFRP strips. The failure criteria including ultimate capacity, mode of failure, initial stiffness, ductility and the developed ultimate strain in the reinforcing steel and CFRP were considered and compared for each group for the control and the CFRP-strengthened specimens. The test results showed that the proposed CFRP strengthening configurations represented the best choice for strengthening the first two defects from the viewpoint of the studied failure criteria. On the other hand, the results of the third group showed that strengthening the joint using NSM strip technique enabled the specimen to outperform the structural performance of the control specimen while strengthening the joints using externally bonded CFRP strips and sheets failed to restore the strengthened joints capacity.

  14. Strengthening of defected beam–column joints using CFRP

    Directory of Open Access Journals (Sweden)

    Mohamed H. Mahmoud

    2014-01-01

    Full Text Available This paper presents an experimental study for the structural performance of reinforced concrete (RC exterior beam–column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP. The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered defects include the absence of the transverse reinforcement within the joint core, insufficient bond length for the beam main reinforcement and inadequate spliced implanted column on the joint. Three different strengthening schemes were used to rehabilitate the defected beam–column joints including externally bonded CFRP strips and sheets in addition to near surface mounted (NSM CFRP strips. The failure criteria including ultimate capacity, mode of failure, initial stiffness, ductility and the developed ultimate strain in the reinforcing steel and CFRP were considered and compared for each group for the control and the CFRP-strengthened specimens. The test results showed that the proposed CFRP strengthening configurations represented the best choice for strengthening the first two defects from the viewpoint of the studied failure criteria. On the other hand, the results of the third group showed that strengthening the joint using NSM strip technique enabled the specimen to outperform the structural performance of the control specimen while strengthening the joints using externally bonded CFRP strips and sheets failed to restore the strengthened joints capacity.

  15. Prospects for Precision Measurement of CO2 Column from Space

    Science.gov (United States)

    Heaps, William S.; Kawa, S. Randolph; Burris, John F.; Wilson, Emily L.; Georgieva, Elena; Miodek, Marty

    2005-01-01

    In order to address the problem of sources and sinks of CO2 measurements are needed on a global scale. Clearly a satellite is a promising approach to meeting this requirement. Unfortunately, most methods for making a CO2 measurement from space involve the whole column. Since sources and sinks at the surface represent a small perturbation to the total column one is faced with the need to measure the column with a precision better than 1%. No species has ever been measured from space at this level. We have developed over the last 3 years a small instrument based upon a Fabry-Perot interferometer that is very sensitive to atmospheric CO2 and has a high signal to noise ratio. We have tested this instrument in a ground based configuration and from aircraft platforms simulating operation from a satellite. We will present results from these tests and discuss ways that this promising new instrument could be used to improve our understanding of the global carbon budget.

  16. Towards Coated Nano-Gold Particles as Non-Reactive Tracers in Coated nZVI for In-Situ Remediation

    DEFF Research Database (Denmark)

    Fjordbøge, Annika Sidelmann; Uthuppu, Basil; Caspersen, Eva

    2014-01-01

    different DNAPLs (tri- and tetrachloroethene) was tested. The nAu mobility was investigated in sand packed columns and the breakthrough was monitored using spectrophotometry on the effluent. Results/Lessons Learned. The results showed nanoparticles with great mobility and a significant affinity...... for the DNAPL. The breakthrough curve from the mobility study showed that only minimal retardation and tailing occurred at both the front and back of the nAu plume. These results obtained by conducting model experiments (lab scale aerobic) using nAu coated with amphiphilic block copolymers like PVP-VA and PVA...

  17. A comparative analysis of energy dissipation and equivalent viscous damping of RC columns subjected to uniaxial and biaxial loading

    OpenAIRE

    Hugo Rodrigues; Humberto Varum; Antonio Arede; Anibal Costa

    2012-01-01

    The hysteretic behaviour of RC columns has been object of many experimental studies over the past years. However, the majority of these studies are focused on unidirectional loading. An experimental program was carried out where 24 columns were tested for different loading histories, under uniaxial and biaxial conditions. The experimental results are presented in this paper and are discussed in terms of global column behaviour, and particularly with regards to energy dissipation and damping c...

  18. Thermal protection of reinforced concrete columns strengthened by GFRP laminates (experimental and theoretical study

    Directory of Open Access Journals (Sweden)

    Hossam Z. El-Karmoty

    2012-08-01

    Full Text Available Fiber reinforced polymer (FRP has been used over the last decade in the form of laminates for strengthening reinforced concrete elements. Non-corrosive characteristics, high strength and good fatigue properties of FRP significantly increase the service life of structures. However, FRP have a negligible resistance to fire. This is mainly due to the fact that the epoxy adhesive used in the application of FRP is badly deteriorated by high degree of temperature. The current paper studies fire protection of glass fiber reinforced polymer (GFRP laminates used in strengthening reinforced concrete columns. The experimental program of this study included testing of seven reinforced concrete circular columns. Two columns were tested as control columns. Five columns were exposed to high degree of temperature, while being loaded, to simulate the actual situation in structures. Two different systems for protecting GFRP laminates against fire were used with varying thickness. Specimens were exposed to high degree of temperature by different durations and then reloaded to measure the residual strength. The behavior and failure modes of the strengthened concrete columns exposed to high degree of temperature are presented. Recommendations for application of protective coating to FRP systems against high degree of temperature are given. Theoretical analysis was also carried out to predict the load capacity of the reinforced concrete columns strengthened by GFRP laminates. Evaluation of the analytical work was introduced and compared to the results of the experimental work.

  19. Cyclic performance and simplified pushover analyses of precast segmental concrete bridge columns with circular section

    Science.gov (United States)

    Bu, Zhanyu; Guo, Jian; Zheng, Rongyue; Song, Jianwei; Lee, George C.

    2016-06-01

    In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed configuration and appropriate design procedure to ensure a comparable performance with monolithic construction has impeded this structural system from being widely used in areas of high seismicity. In this study, precast segmental bridge column cyclic loading tests were conducted to investigate the performance of unbonded post-tensioned segmental bridge columns. One monolithic and two precast segmental columns were tested. The precast segmental column exhibited minor damage and small residual displacement after the maximum 7% cyclic drift; energy dissipation (ED) can be enhanced byadding ED bars. The experimental results were modeled by a simplified pushover method (SPOM), as well as a fiber model (FIBM) finite element method. Forty-five cases of columns with different aspect ratios, axial load ratios and ED bar ratios were analyzed with the SPOM and FIBM, respectively. Using these parametric results, a simplified design method was suggested by regressive analysis. Satisfactory correlation was found between the experimental results and the simplified design method for precast segmental columns with different design parameters.

  20. ADAM28 localizes to HLA-G+ trophoblasts and promotes column cell outgrowth.

    Science.gov (United States)

    De Luca, L C; Le, H T; Mara, D L; Beristain, A G

    2017-07-01

    Trophoblast progenitor cell differentiation towards the extravillous trophoblast (EVT) lineage initiates within proximal regions of anchoring columns of first trimester placental villi. While molecular processes controlling the initial stages of progenitor cell differentiation along the EVT pathway have been described, much remains unknown about factors important in distal column cell differentiation into invasive EVTs. ADAMs are proteases that regulate growth factor signaling, cell-matrix adhesion, and matrix proteolysis, and thus impact many processes relevant in placentation. Global gene expression studies identified the ADAM subtype, ADAM28, to be highly expressed in EVT-like trophoblasts, suggesting that it may play a role in EVT function. This study aims to test the functional importance of ADAM28 in column cell outgrowth and maintenance. ADAM28 mRNA levels and protein localization were determined by qPCR and immunofluorescence microscopy analyses in purified placental villi cell populations and tissues. ADAM28 function in trophoblast column outgrowth was examined using ADAM28-targetting siRNAs in Matrigel-imbedded placental explant cultures. Within placental villi, ADAM28 mRNA levels were highest in HLA-G+ column trophoblasts, and consistent with this, ADAM28 was preferentially localized to HLA-G+ trophoblasts within distal anchoring columns and decidual tissue. siRNA-directed loss of ADAM28 impaired trophoblast column outgrowth and resulted in increased apoptosis in matrix-invading trophoblasts. Our findings suggest that ADAM28 promotes column outgrowth by providing survival cues within anchoring column cells. This study also provides insight into a possible role for ADAM28 in driving differentiation of column trophoblasts into invasive HLA-G+ EVT subsets. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Column flotation results at Powell Mountain Coal Company

    Energy Technology Data Exchange (ETDEWEB)

    Peters, W.J. Parekh, B.K. (Powell Mountain Coal Co. (US))

    1992-01-01

    In 1989 a column flotation process was developed at the CAER, which enabled the economical recovery of coal fines from high-ash fine refuse. The laboratory design was expanded to commercial scale and installed at the Mayflower Coal Preparation Plant of Powell Mountain Coal Company in December, 1989. It has been in continuous operation there since that time. This article is a summary of the past two years' experiences with this applied technology, applicable dewatering tests and flotation tests results from the plant.

  2. On the Origin of the High Column Density Turnover in the H I Column Density Distribution

    Science.gov (United States)

    Erkal, Denis; Gnedin, Nickolay Y.; Kravtsov, Andrey V.

    2012-12-01

    We study the high column density regime of the H I column density distribution function and argue that there are two distinct features: a turnover at N H I ≈ 1021 cm-2, which is present at both z = 0 and z ≈ 3, and a lack of systems above N H I ≈ 1022 cm-2 at z = 0. Using observations of the column density distribution, we argue that the H I-H2 transition does not cause the turnover at N H I ≈ 1021 cm-2 but can plausibly explain the turnover at N H I >~ 1022 cm-2. We compute the H I column density distribution of individual galaxies in the THINGS sample and show that the turnover column density depends only weakly on metallicity. Furthermore, we show that the column density distribution of galaxies, corrected for inclination, is insensitive to the resolution of the H I map or to averaging in radial shells. Our results indicate that the similarity of H I column density distributions at z = 3 and 0 is due to the similarity of the maximum H I surface densities of high-z and low-z disks, set presumably by universal processes that shape properties of the gaseous disks of galaxies. Using fully cosmological simulations, we explore other candidate physical mechanisms that could produce a turnover in the column density distribution. We show that while turbulence within giant molecular clouds cannot affect the damped Lyα column density distribution, stellar feedback can affect it significantly if the feedback is sufficiently effective in removing gas from the central 2-3 kpc of high-redshift galaxies. Finally, we argue that it is meaningful to compare column densities averaged over ~ kpc scales with those estimated from quasar spectra that probe sub-pc scales due to the steep power spectrum of H I column density fluctuations observed in nearby galaxies.

  3. Contributions to reversed-phase column selectivity: III. Column hydrogen-bond basicity.

    Science.gov (United States)

    Carr, P W; Dolan, J W; Dorsey, J G; Snyder, L R; Kirkland, J J

    2015-05-22

    Column selectivity in reversed-phase chromatography (RPC) can be described in terms of the hydrophobic-subtraction model, which recognizes five solute-column interactions that together determine solute retention and column selectivity: hydrophobic, steric, hydrogen bonding of an acceptor solute (i.e., a hydrogen-bond base) by a stationary-phase donor group (i.e., a silanol), hydrogen bonding of a donor solute (e.g., a carboxylic acid) by a stationary-phase acceptor group, and ionic. Of these five interactions, hydrogen bonding between donor solutes (acids) and stationary-phase acceptor groups is the least well understood; the present study aims at resolving this uncertainty, so far as possible. Previous work suggests that there are three distinct stationary-phase sites for hydrogen-bond interaction with carboxylic acids, which we will refer to as column basicity I, II, and III. All RPC columns exhibit a selective retention of carboxylic acids (column basicity I) in varying degree. This now appears to involve an interaction of the solute with a pair of vicinal silanols in the stationary phase. For some type-A columns, an additional basic site (column basicity II) is similar to that for column basicity I in primarily affecting the retention of carboxylic acids. The latter site appears to be associated with metal contamination of the silica. Finally, for embedded-polar-group (EPG) columns, the polar group can serve as a proton acceptor (column basicity III) for acids, phenols, and other donor solutes. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Experimental Study on Fibre-reinforced Cementitious Matrix Confined Concrete Columns under Axial Compression

    Directory of Open Access Journals (Sweden)

    Lan Zeng

    2017-03-01

    Full Text Available Poor fire resistance of fibre-reinforced polymer (FRP restricts its further application in construction structures. In this paper, a novel fibre-reinforced cementitious matrix confined concrete column (FRCMCC using fireproof grout as the fibre matrix was developed, and experiments were conducted to establish its performance and analyse the mechanical properties under axial compression. The test results show that its failure mode was more moderate compared to the traditional fibre-reinforced resinous matrix confined concrete column (FRRMCC, and the concrete columns confined with multi-layer fibres and end reinforcement could provide both good strength and ductility.

  5. Influence of the column rectangularity index and of the boundary conditions in the punching resistance of slab-column connections

    Directory of Open Access Journals (Sweden)

    O. S. PAIVA

    Full Text Available Experimental evidence indicates that both the column rectangularity index and the boundary conditions of the connection may affect the ultimate punching resistance. This paper presents general aspects of these topics and, through the analysis of experimental results of tests on 131 slabs, evaluates the accuracy and suitability of recommendations presented by ABNT NBR 6118, Eurocode 2, ACI 318 and fib Model Code 2010. Experimental results showed that the security level of normative estimates trend to reduce as the column rectangularity increases, and in some cases, the punching resistance was overestimated. Finally, adjustments are suggested in equations presented by NBR 6118 and MC2010 in order to eliminate this trend of unsafe results.

  6. Modeling of rotating disc contactor (RDC) column

    Science.gov (United States)

    Ismail, Wan Nurul Aiffah; Zakaria, Siti Aisyah; Noor, Nor Fashihah Mohd; Sulong, Ibrahim; Arshad, Khairil Anuar

    2014-12-01

    Liquid-liquid extraction is one of the most important separation processes. Different kinds of liquid-liquid extractor such as Rotating Disc Contactor (RDC) Column being used in industries. The study of liquid-liquid extraction in an RDC column has become a very important subject to be discussed not just among chemical engineers but mathematician as well. In this research, the modeling of small diameter RDC column using the chemical system involving cumene/isobutryric asid/water are analyzed by the method of Artificial Neural Network (ANN). In the previous research, we begin the process of analyzed the data using methods of design of the experiments (DOE) to identify which factor and their interaction factor are significant and to determine the percentage of contribution of the variance for each factor. From the result obtained, we continue the research by discussed the development and validation of an artificial neural network model in estimating the concentration of continuous and concentration of dispersed outlet for an RDC column. It is expected that an efficient and reliable model will be formed to predict RDC column performance as an alternative to speed up the simulation process.

  7. Vertebral Column Resection for Rigid Spinal Deformity.

    Science.gov (United States)

    Saifi, Comron; Laratta, Joseph L; Petridis, Petros; Shillingford, Jamal N; Lehman, Ronald A; Lenke, Lawrence G

    2017-05-01

    Broad narrative review. To review the evolution, operative technique, outcomes, and complications associated with posterior vertebral column resection. A literature review of posterior vertebral column resection was performed. The authors' surgical technique is outlined in detail. The authors' experience and the literature regarding vertebral column resection are discussed at length. Treatment of severe, rigid coronal and/or sagittal malalignment with posterior vertebral column resection results in approximately 50-70% correction depending on the type of deformity. Surgical site infection rates range from 2.9% to 9.7%. Transient and permanent neurologic injury rates range from 0% to 13.8% and 0% to 6.3%, respectively. Although there are significant variations in EBL throughout the literature, it can be minimized by utilizing tranexamic acid intraoperatively. The ability to correct a rigid deformity in the spine relies on osteotomies. Each osteotomy is associated with a particular magnitude of correction at a single level. Posterior vertebral column resection is the most powerful posterior osteotomy method providing a successful correction of fixed complex deformities. Despite meticulous surgical technique and precision, this robust osteotomy technique can be associated with significant morbidity even in the most experienced hands.

  8. Bioremediation of PAH polluted soils: column studies

    Energy Technology Data Exchange (ETDEWEB)

    Hallberg, R.O. [Dept. of Geology and Geochemistry, Stockholm Univ., Stockholm (Sweden); Trepte, B.S. [Angpannefoereningen AB, Stockholm (Sweden)

    2003-07-01

    Background. Due to spills, discharges and leakage, the gaswork site at Husarviken in Stockholm is today the largest (36 ha) creosote-contaminated site in Sweden. The main pollutants are creosote, lead and mercury. The remediation costs are estimated to be as high as US $125 million. It is thus of great interest to find more cost effective remediation methods. Objectives. The aim of this study was to investigate i) if the addition of NTA, EDTA, nitrate, iron and dry yeast would enhance the bioremediation rate of a complex organic pollutant like PAH and, if so, at what concentrations they would be most efficient, ii) the effect on PAH reduction when larger dimensions of the column is used to diminish the effect of water passing along the sides of the column, iii) long-term effects on the reduction of PAH in field-contaminated soil with high concentrations. Materials and Methods. Creosote-contaminated soil from the Husarviken gaswork site was treated with aerated water in column experiments at room temperature. Three column experiments were performed in 2 and 100 L of homogenised soil samples percolated by recirculating flushing water. Fluoranthene was analysed as a representative of the overall degradation of PAH in the columns. (orig.)

  9. Effect of backmixing on pulse column performance

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Y.W.

    1979-05-01

    A critical survey of the published literature concerning dispersed phase holdup and longitudinal mixing in pulsed sieve-plate extraction columns has been made to assess the present state-of-the-art in predicting these two parameters, both of which are of critical importance in the development of an accurate mathematical model of the pulse column. Although there are many conflicting correlations of these variables as a function of column geometry, operating conditions, and physical properties of the liquid systems involved it has been possible to develop new correlations which appear to be useful and which are consistent with much of the available data over the limited range of variables most likely to be encountered in plant sized equipment. The correlations developed were used in a stagewise model of the pulse column to predict product concentrations, solute inventory, and concentration profiles in a column for which limited experimental data were available. Reasonable agreement was obtained between the mathematical model and the experimental data. Complete agreement, however, can only be obtained after a correlation for the extraction efficiency has been developed. The correlation of extraction efficiency was beyond the scope of this work.

  10. Performance of externally CFRP confined RC columns with changes in thickness of the wrap, slenderness of the column and shape of the section

    Directory of Open Access Journals (Sweden)

    Gahmous M.

    2012-09-01

    Full Text Available The present study deals with the analysis of experimental results, in terms of load carrying capacity and strains, obtained from tests on reinforced concrete (RC columns, strengthened with external carbon fiber reinforced polymer (CFRP sheets. The experimental parameters include: number of wrap layers, slenderness of the columns (L/a or L/D and shape of the section (circular and square. A total of 48 specimens were subjected to axial compression. All test specimens were loaded to failure in axial compression. Compressive stress, axial and hoop strains have been recorded to evaluate the stress-strain relationship, ultimate strength, stiffness, and ductility of the specimens. Results clearly demonstrate that composite wrapping can enhance the structural performance of RC columns in terms of both maximum strength and ductility. The effects of test parameters are evidenced and compared.

  11. Mathematical modeling of alcohol distillation columns

    Directory of Open Access Journals (Sweden)

    Ones Osney Pérez

    2011-04-01

    Full Text Available New evaluation modules are proposed to extend the scope of a modular simulator oriented to the sugar cane industry, called STA 4.0, in a way that it can be used to carry out x calculation and analysis in ethanol distilleries. Calculation modules were developed for the simulation of the columns that are combined in the distillation area. Mathematical models were supported on materials and energy balances, equilibrium relations and thermodynamic properties of the ethanol-water system. Ponchon-Savarit method was used for the evaluation of the theoretical stages in the columns. A comparison between the results using Ponchon- Savarit method and those obtained applying McCabe-Thiele method was done for a distillation column. These calculation modules for ethanol distilleries were applied to a real case for validation.

  12. Neutron camera employing row and column summations

    Science.gov (United States)

    Clonts, Lloyd G.; Diawara, Yacouba; Donahue, Jr, Cornelius; Montcalm, Christopher A.; Riedel, Richard A.; Visscher, Theodore

    2016-06-14

    For each photomultiplier tube in an Anger camera, an R.times.S array of preamplifiers is provided to detect electrons generated within the photomultiplier tube. The outputs of the preamplifiers are digitized to measure the magnitude of the signals from each preamplifier. For each photomultiplier tube, a corresponding summation circuitry including R row summation circuits and S column summation circuits numerically add the magnitudes of the signals from preamplifiers for each row and for each column to generate histograms. For a P.times.Q array of photomultiplier tubes, P.times.Q summation circuitries generate P.times.Q row histograms including R entries and P.times.Q column histograms including S entries. The total set of histograms include P.times.Q.times.(R+S) entries, which can be analyzed by a position calculation circuit to determine the locations of events (detection of a neutron).

  13. Analyzing Dendritic Morphology in Columns and Layers.

    Science.gov (United States)

    Ting, Chun-Yuan; McQueen, Philip G; Pandya, Nishith; McCreedy, Evan S; McAuliffe, Matthew; Lee, Chi-Hon

    2017-03-23

    In many regions of the central nervous systems, such as the fly optic lobes and the vertebrate cortex, synaptic circuits are organized in layers and columns to facilitate brain wiring during development and information processing in developed animals. Postsynaptic neurons elaborate dendrites in type-specific patterns in specific layers to synapse with appropriate presynaptic terminals. The fly medulla neuropil is composed of 10 layers and about 750 columns; each column is innervated by dendrites of over 38 types of medulla neurons, which match with the axonal terminals of some 7 types of afferents in a type-specific fashion. This report details the procedures to image and analyze dendrites of medulla neurons. The workflow includes three sections: (i) the dual-view imaging section combines two confocal image stacks collected at orthogonal orientations into a high-resolution 3D image of dendrites; (ii) the dendrite tracing and registration section traces dendritic arbors in 3D and registers dendritic traces to the reference column array; (iii) the dendritic analysis section analyzes dendritic patterns with respect to columns and layers, including layer-specific termination and planar projection direction of dendritic arbors, and derives estimates of dendritic branching and termination frequencies. The protocols utilize custom plugins built on the open-source MIPAV (Medical Imaging Processing, Analysis, and Visualization) platform and custom toolboxes in the matrix laboratory language. Together, these protocols provide a complete workflow to analyze the dendritic routing of Drosophila medulla neurons in layers and columns, to identify cell types, and to determine defects in mutants.

  14. Retention Models on Core-Shell Columns.

    Science.gov (United States)

    Jandera, Pavel; Hájek, Tomáš; Růžičková, Marie

    2017-07-13

    A thin, active shell layer on core-shell columns provides high efficiency in HPLC at moderately high pressures. We revisited three models of mobile phase effects on retention for core-shell columns in mixed aqueous-organic mobile phases: linear solvent strength and Snyder-Soczewiński two-parameter models and a three-parameter model. For some compounds, two-parameter models show minor deviations from linearity due to neglect of possible minor retention in pure weak solvent, which is compensated for in the three-parameter model, which does not explicitly assume either the adsorption or the partition retention mechanism in normal- or reversed-phase systems. The model retention equation can be formulated as a function of solute retention factors of nonionic compounds in pure organic solvent and in pure water (or aqueous buffer) and of the volume fraction of an either aqueous or organic solvent component in a two-component mobile phase. With core-shell columns, the impervious solid core does not participate in the retention process. Hence, the thermodynamic retention factors, defined as the ratio of the mass of the analyte mass contained in the stationary phase to its mass in the mobile phase in the column, should not include the particle core volume. The values of the thermodynamic factors are lower than the retention factors determined using a convention including the inert core in the stationary phase. However, both conventions produce correct results if consistently used to predict the effects of changing mobile phase composition on retention. We compared three types of core-shell columns with C18-, phenyl-hexyl-, and biphenyl-bonded phases. The core-shell columns with phenyl-hexyl- and biphenyl-bonded ligands provided lower errors in two-parameter model predictions for alkylbenzenes, phenolic acids, and flavonoid compounds in comparison with C18-bonded ligands.

  15. 29 CFR 1926.756 - Beams and columns.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Beams and columns. 1926.756 Section 1926.756 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.756 Beams and columns. (a.... (c) (1) Double connections at columns and/or at beam webs over a column. When two structural members...

  16. Ground improvement using soil–cement columns: Experimental investigation

    Directory of Open Access Journals (Sweden)

    Ahmed Farouk

    2013-12-01

    Full Text Available The construction of heavy structures on soils of low relative density is a challenging task. The inclusion of soil–cement columns produced by the deep mixing method is one of the soil stabilizing techniques that could be applied successfully to overcome this challenge. Nevertheless, this technique did not receive a considerable attention in Egypt yet. In the first part of this study, two different natural silty sand soils extracted from the Delta of the River Nile were mixed with cement to prepare samples of different cement doses and different water cement ratios. After curing, the hardened samples were tested and their unconfined compressive strength was investigated. The second part of this study investigates the interaction between a strip footing model and Nile deltaic soil improved by a group of soil–cement columns. Results of the first part of this study showed that the compressive strength of the investigated Nile delta soils could be increased even at lower values of cement doses. Results extracted from the second part of this study showed that a considerable settlement reduction up to 80% could be achieved depending on both the number and the length of the soil–cement columns that is used to improve the soil.

  17. CEC separation of heterocyclic amines using methacrylate monolithic columns.

    Science.gov (United States)

    Barceló-Barrachina, Elena; Moyano, Encarnación; Puignou, Lluís; Galceran, Maria Teresa

    2007-06-01

    Two methacrylate-based monolithic columns, one with a negatively charged group (sulfonic group) and another with a new monomer N,N-dimethylamino ethyl acrylate (DMAEA), were prepared and tested for the separation of basic compounds by CEC. This new monolithic stationary phase was prepared by the in situ polymerization of DMAEA with butyl methacrylate and ethylene dimethacrylate, using a ternary porogenic solvent consisting of water, 1-propanol and 1,4-butanediol. The performance of this column was evaluated by means of the analysis of a family of heterocyclic amines. Separation conditions such as pH, amount of organic modifier, ionic strength and elution mode (normal or counterdirectional flow) were studied. At the optimal running electrolyte composition, and using the counterdirectional mode, symmetrical electrochromatographic peaks were obtained, with the number of theoretical plates up to 30,000 and a good resolution between closely related peaks. The 2-acrylamido-2-methyl-1-propane-sulfonic acid column was used for CEC-MS, taking advantage of the compatibility of its elution mode (normal flow) with the MS coupling.

  18. Fabry-Perot Interferometer for Column CO2: Airborne

    Science.gov (United States)

    Kawa, S. R.; Heaps, W. S.; Mao, J.; Andrews, A. E.; Burris, J. F.; Miodek, M.; Georgieva, E.

    2002-01-01

    Global atmospheric CO2 measurements are essential to resolving significant discrepancies in our understanding of the global carbon budget and, hence, humankind's role in global climate change. The science measurement requirements for CO2 are, however, extremely demanding (precision approximately 0.3%). We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere that should be able to achieve sufficient sensitivity and signal-to-noise to measure column CO2 at the target specification. We are currently constructing a prototype instrument for deployment on aircraft. The aircraft version will measure total column CO2 and CO2 below the aircraft as well as O2, which allows normalization of CO2 column amounts for varying surface height and pressure. This instrument will be a valuable asset in carbon budget field studies as well as a useful tool for evaluating existing and future space-based CO2 measurements. We will present the instrument concept, sensitivity calculations, and the results of testing a bench system in the laboratory and outdoors on the ground. We will also discuss our plan for deployment on the aircraft and potential flight applications to the CO2 budget problem.

  19. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique......) mixture of random Rasch distributions. The non-degenerate elements of these distributions were introduced by Rasch (1960). We investigate the relationship between these random Rasch distributions and a problem in visual perception, the characters of a certain Abelian semigroup, and the problem...

  20. Monolithic molecularly imprinted polymeric capillary columns for isolation of aflatoxins.

    Science.gov (United States)

    Szumski, Michał; Grzywiński, Damian; Prus, Wojciech; Buszewski, Bogusław

    2014-10-17

    Monolithic molecularly imprinted polymers extraction columns have been prepared in fused-silica capillaries by UV or thermal polymerization in a two-step process. First, a poly-(trimethylolpropane trimethacrylate) (polyTRIM) core monolith was synthesized either by UV or thermal polymerization. Then it was grafted with the mixture of methacrylic acid (MAA) as a functional monomer, ethylene dimethacrylate (EDMA) as a cross-linking agent, 5,7-dimethoxycoumarin (DMC) as an aflatoxin-mimicking template, toluene as a porogen solvent and 2,2-azobis-(2-methylpropionitrile) (AIBN) as an initiator of the polymerization reaction. Different thermal condition of the photografting and different concentrations of the grafting mixture were tested during polymerization. The extraction capillary columns were evaluated in the terms of their hydrodynamic and chromatographic properties. Retention coefficients for aflatoxin B1 and DMC were used for assessment of the selectivity and imprinting factor. The obtained results indicate that the temperature of photografting and concentration of the grafting mixture are key parameters that determine the quality of the prepared MIPs. From the MIP columns characterized by the highest permeability the column of the highest imprinting factor was applied for isolation of aflatoxins B1, B2, G1 and G2 from the model aqueous sample followed by on-line chromatographic separation. The process was performed using a micro-MISPE-microLC-LIF system of a novel design, which allowed for detection of the eluates from the sample preparation part as well as from the chromatographic separation. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Mathematical Modeling of Column-Base Connections under Monotonic Loading

    Directory of Open Access Journals (Sweden)

    Gholamreza Abdollahzadeh

    2014-12-01

    Full Text Available Some considerable damage to steel structures during the Hyogo-ken Nanbu Earthquake occurred. Among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. The lessons from these phenomena led to the need for improved understanding of column base behavior. Joint behavior must be modeled when analyzing semi-rigid frames, which is associated with a mathematical model of the moment–rotation curve. The most accurate model uses continuous nonlinear functions. This article presents three areas of steel joint research: (1 analysis methods of semi-rigid joints; (2 prediction methods for the mechanical behavior of joints; (3 mathematical representations of the moment–rotation curve. In the current study, a new exponential model to depict the moment–rotation relationship of column base connection is proposed. The proposed nonlinear model represents an approach to the prediction of M–θ curves, taking into account the possible failure modes and the deformation characteristics of the connection elements. The new model has three physical parameters, along with two curve-fitted factors. These physical parameters are generated from dimensional details of the connection, as well as the material properties. The M–θ curves obtained by the model are compared with published connection tests and 3D FEM research. The proposed mathematical model adequately comes close to characterizing M–θ behavior through the full range of loading/rotations. As a result, modeling of column base connections using the proposed mathematical model can give crucial beforehand information, and overcome the disadvantages of time consuming workmanship and cost of experimental studies.

  2. The Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths

    Directory of Open Access Journals (Sweden)

    Hongying Dong

    2014-12-01

    Full Text Available In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete’s compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength.

  3. The Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths.

    Science.gov (United States)

    Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei

    2014-12-08

    In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete's compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength.

  4. Intertidal water column meiofauna in relation to wave intensity on an exposed beach

    Directory of Open Access Journals (Sweden)

    J. Germán Rodríguez

    2004-04-01

    Full Text Available Since the 1970s, various studies have shown that some meiofaunal taxa frequently occur in the water column. Water currents or any process that disturbs the sediments are possible factors that can facilitate the passive entry of meiofauna in the water column. Wave action has been predicted as one of these factors (Armonies, 1994, suggesting a correlation between the number of eroded specimens and wave intensity should exist. As a test of this prediction, replicated samples were taken in the water column, swash sediment and back-swash water in an exposed beach (Island of Sylt, northern Wadden Sea. Wave height and period were measured to characterise the energy regime. Samplings were carried out over a nine day period in August 2000, at diurnal mid-tide time. Wave height and period varied significantly among collections. Densities of nematodes, harpacticoids, nauplii, platyhelminthes, ostracods and bivalve larvae in the water column, swash sediment and back-swash water varied significantly among collections. Nevertheless, no significant correlation was found between water column density and wave characteristics. Density of meiofauna in the water column was not correlated with density in the sediment or in back-swash water. Therefore wave intensity did not explain the variability of meiofaunal densities present in the water column.

  5. Behaviour of FRP confined concrete in square columns

    Directory of Open Access Journals (Sweden)

    de Diego, A.

    2015-12-01

    Full Text Available A significant amount of research has been conducted on FRP-confined circular columns, but much less is known about rectangular/square columns in which the effectiveness of confinement is much reduced. This paper presents the results of experimental investigations on low strength square concrete columns confined with FRP. Axial compression tests were performed on ten intermediate size columns. The tests results indicate that FRP composites can significantly improve the bearing capacity and ductility of square section reinforced concrete columns with rounded corners. The strength enhancement ratio is greater the lower the concrete strength and also increases with the stiffness of the jacket. The confined concrete behaviour was predicted according to the more accepted theoretical models and compared with experimental results. There are two key parameters which critically influence the fitting of the models: the strain efficiency factor and the effect of confinement in non-circular sections.La mayoría de las investigaciones sobre hormigón confinado con FRP se han realizado sobre pilares de sección circular, pero el comportamiento en secciones cuadradas/rectangulares, donde el confinamiento es menos eficaz, es mucho menos conocido. Este trabajo presenta los resultados de un estudio experimental sobre probetas de hormigón de baja resistencia y sección cuadrada. Se han ensayado a compresión centrada diez probetas de tamaño intermedio. Los resultados indican que el confinamiento mejora significativamente la resistencia y ductilidad del hormigón en columnas de sección cuadrada con las esquinas redondeadas. El incremento de resistencia es mayor cuanto menor es la resistencia del hormigón sin confinar y también aumenta con la rigidez del encamisado. Los resultados se compararon con los obtenidos según los modelos teóricos más aceptados. Hay dos parámetros críticos en el ajuste de los modelos: el factor de eficiencia de la deformación y el

  6. Robust Geometric Control of a Distillation Column

    DEFF Research Database (Denmark)

    Kymmel, Mogens; Andersen, Henrik Weisberg

    1987-01-01

    A frequency domain method, which makes it possible to adjust multivariable controllers with respect to both nominal performance and robustness, is presented. The basic idea in the approach is that the designer assigns objectives such as steady-state tracking, maximum resonance peaks, bandwidth, m...... is used to examine and improve geometric control of a binary distillation column....

  7. Superior dislocation hip with anterior column acetabular

    African Journals Online (AJOL)

    abp

    2012-06-21

    Jun 21, 2012 ... Abstract. Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was ...

  8. Thermal Analysis of LANL Ion Exchange Column

    Energy Technology Data Exchange (ETDEWEB)

    Laurinat, J.E.

    1999-06-16

    This document reports results from an ion exchange column heat transfer analysis requested by Los Alamos National Laboratory (LANL). The object of the analysis is to demonstrate that the decay heat from the Pu-238 will not cause resin bed temperatures to increase to a level where the resin significantly degrades.

  9. Density Gradient Columns for Chemical Displays.

    Science.gov (United States)

    Guenther, William B.

    1986-01-01

    Procedures for preparing density gradient columns for chemical displays are presented. They include displays illustrating acid-base reactions, metal ion equilibria, and liquid density. The lifetime of these metastable displays is surprising, some lasting for months in display cabinets. (JN)

  10. Synthesis and applications of monolithic HPLC columns

    Science.gov (United States)

    Liang, Chengdu

    Silica and carbon monolithic columns were synthesized and modified for liquid chromatography applications. Column configurations and cladding techniques were investigated in detail. Three novel approaches have been developed for the synthesis of bimodal porous rods. Out of these three methods, gel-casting was adopted for the synthesis of silica monoliths with ordered mesopores and uniform macropores; the use of colloidal templates and dual phase separation has been successfully implemented for the synthesis of carbon monoliths with well-controlled meso- and macro- porosities. The formation of mesopores in carbon materials has been further studied in the microphase separation of block copolymers. Electrochemical modification of carbon monoliths was discovered to be an efficient method for converting covalently bonded functionalities to carbon monoliths. N,N'-diethylaminobenzene has been attached to carbon surface for the separation of proteins and protein digests. The performances of carbon-based monolithic columns were studied intensely through frontal analysis and Van Deemter plot. Temperature and pressure effects were also investigated in carbon-based columns. The density of bonding on the modified carbon monoliths was characterized by thermogravimetric analysis.

  11. Chief Editor's column/Science Smiles

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 1; Issue 4. Chief Editor's column / Science Smiles. R K Laxman. Science Smiles Volume 1 Issue 4 April 1996 pp 4-4. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/001/04/0004-0004. Author Affiliations.

  12. [Spondylosis: diseases of the vertebral column].

    Science.gov (United States)

    Pérez, Amador Schüller

    2008-01-01

    Frequent and transcendent diseases for the difficulties of his diagnosis and treatment. The components of the vertebral column, vertebral bodies, discs and unvertebral joints, spondylosis ligaments must be considered to be a functional Unit. The Patology of each one of their parts concerns or reverberates in others.

  13. Compressive Behaviour of RC Column with Fibre Reinforced Concrete Confined by CFRP Strips

    Directory of Open Access Journals (Sweden)

    A. M. Vasumathi

    2014-01-01

    Full Text Available The structural application of synthetic fibre reinforced concrete (FRC has become widespread in the construction industry in order to satisfy the requirement of the earthquake resistant structures. Research conducted so far are focused on the structural behaviour of RC column externally confined with FRP composites, while studies are needed to address the behaviour of FRP strengthened RC column fabricated using fibre reinforced concrete. With the intention that the experimental investigation was carried out to evaluate the feasibility use of CFRP composite strips in strengthening of RC column made with fibre reinforced concrete. Circular synthetic Polypropylene fibre was used in the rate of 0.50% in the volume of concrete. CFRP strips having a width of 50 mm were used to confine the column and the experimental parameters were effective spacing between the CFRP strips (20 mm and 30 mm and the number of CFRP layers (one, two and three. The externally bonded CFRP strips counteract the lateral expansion of the concrete significantly by providing restraining effect and thus effect enhanced the stiffness of the column. The column strengthened with CFRP strips showed a maximum of 198.87% and 91.75% enhancement in axial deformation control and ultimate strength, respectively, compared to that of reference column. From the test results obtained, it is suggested that CFRP strips with the spacing of 20 mm and 30 mm can be used in strengthening of RC column made with FRC; however the column confined with 30 mm spacing provides an economical advantage compared to that of 20 mm spacing.

  14. BCB polymer based row-column addressed CMUT

    DEFF Research Database (Denmark)

    Havreland, Andreas Spandet; Ommen, Martin Lind; Silvestre, Chantal

    This paper presents an inexpensive, low temperature and rapid fabrication method for capacitive micromachined ultrasonic transducers (CMUT). The fabrication utilizes the bonding and dielectric properties of the photosensitive polymer Benzocyclobutene (BCB). A BCB based row-column addressed CMUT...... into water and a pull-in voltage of 75 V. Stability tests have showed a stable coupling coefficient of approximately 0.1 during 10 hours of biased operation. Acoustic measurements, with a hydrophone positioned 1 cm from the CMUTs, have showed a peak-to-peak pressure of 14 kPa....

  15. Behavior of FRP-Confined Concrete-Filled Steel Tube Columns

    Directory of Open Access Journals (Sweden)

    Yiyan Lu

    2014-05-01

    Full Text Available This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP. Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap can effectively confine the concrete expansion and delay the local buckling of the steel tube. Both the load capacity and the axial deformation capacity of concrete-filled steel tube columns can be substantially enhanced with FRP confinement. A model is proposed to predict the load capacity of the FRP-confined concrete-filled steel tube columns. The predicted results are generally in good agreement with the experimental ones obtained in this study and in the literature.

  16. Effect of Concrete Age and Creep on the Behavior of Concrete-Filled Steel Tube Columns

    Directory of Open Access Journals (Sweden)

    HaiYang Wang

    2016-01-01

    Full Text Available The influence of concrete age and creep on the ultimate axial loading capacity of concrete-filled steel tube (CFST columns is experimentally and numerically investigated. After validation of numerical models, a parametric study is conducted and the results are used to formulate empirical formulas for predicting the ultimate axial load-bearing capacity of the columns. Formulas are also proposed for predicting both the composite creep and aging coefficients of the CFST columns, which consider the confinement action of steel tubes on concrete. Then, the proposed formulas are validated independently by comparing their predictions with existing test results performed by other researchers. The comparisons show that the empirical formulas have the potential to be used in the practical design of CFST columns.

  17. Seismic Behavior and Force-Displacement Characterization of Neotype Column-Slab High Piers

    Directory of Open Access Journals (Sweden)

    YanQun Zhou

    2014-01-01

    Full Text Available The seismic behavior and plasticity spreading of a neotype column-slab high pier are researched in this paper. Four scale model tests of a web slab with two boundary columns are carried out under cyclic inelastic lateral displacements simulating seismic response. The test results show that the neotype column-slab high pier has strong and stable bearing capacity, good ductility, and energy dissipation capacity. The experimental values pertaining to the spread of plasticity are derived. An approach for deriving the spread of plasticity analytically is deduced and applied to the four tests. This method accurately assesses a pier’s spread of plasticity for most ductility levels. At nearly all ductility levels, the mean difference between analytical assessments of the spread of plasticity and results from 4 large-scale tests is 12% with a 9% coefficient of variation.

  18. Determination of the vildagliptin intermediate enantiomer by chiralce-columns

    Directory of Open Access Journals (Sweden)

    Weina LI

    2017-06-01

    Full Text Available In order to establish a NP-HPLC method for the determination of enantiomer in vildagliptin intermediate, the determination is carried out on the column of ChiralpakAD-H(250 mm×4.6 mm, 5 μm, with the mobile phase of n-hexane, ethanol and methanol(volume ratio of 65∶25∶10)at flow rate of 0.8 mL/min. The sample volume is 10 μL, the wavelength is 210 nm and the column temperature is 35 ℃. The result shows that the vildagliptin intermediate and its enantiomer could be well separated and detected effectively; blank solvent doesn't interfere with the enantiomer assaying; the detection limit is 27 ng/mL and the quantification limit is 81 ng/mL; in repetitive test, the RSD of enantiomer assaying of samples are no more than 2.0%; in stability test, the RSD are no more than 2.0% in 12 h; the vildagliptin intermediate and its enantiomer could be well separated in the test of durability with all RSDs below 2.0%. The method is simple, reliable, accurate and durable, and can be used for determination of enantiomer in vildagliptin intermediate.

  19. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  20. Beam to Column Timber Joints with Pretensioned Bolts

    Directory of Open Access Journals (Sweden)

    Hayashikawa T.

    2011-01-01

    Full Text Available The effects of pretension in bolts on hysteretic response of timber joints exposed to a bending had been reported by the authors, but the cyclic tests were carried out at small displacement level which might not be applicable for earthquake-resistance design. In this study, similar cyclic tests but at large displacement levels were conducted. Beam to column timber joints with steel side plates were fabricated and continuously loaded until failure. At connection, the bolts were pretension in four different magnitudes: 0 kN, 5 kN, 10 kN and 15 kN. The results showed that frictional action between the steel side plates and wood member as a result of bolt pretensioning significantly increased the (frictional hysteretic damping and the equivalent viscous damping ratio. It is obvious from the test results that the pretension force in bolts has no influence on the maximum joint resistance but decreases the joint rotational deformation.

  1. Imidacloprid mobility and logevity in soil columns at a termiticidal application rate

    Science.gov (United States)

    Chris J. Peterson

    2007-01-01

    The mobility, longevity and termiticidal activity of imidacloprid (Premise 2 termiticide; BayerEnvironmental Sciences) at the termiticidal labeled rate for perimeter treatment were tested in vegetated and non-vegetated soil columns in two tests: in cone plots and in polyvinyl chloride (PVC) pipes. Imidacloprid content in the...

  2. Preliminary Design of Reactive Distillation Columns

    OpenAIRE

    Thery, Raphaële; Meyer, Xuân-Mi; Joulia, Xavier; Meyer, Michel

    2005-01-01

    A procedure that combines feasibility analysis, synthesis and design of reactive distillation columns is introduced. The main interest of this methodology lies on a progressive introduction of the process complexity. From minimal information concerning the physicochemical properties of the system, three steps lead to the design of the unit and the specification of its operating conditions. Most of the methodology exploits and enriches approaches found in the literature. Each step is des...

  3. Seismic Response of a Platform-Frame System with Steel Columns

    Directory of Open Access Journals (Sweden)

    Davide Trutalli

    2017-04-01

    Full Text Available Timber platform-frame shear walls are characterized by high ductility and diffuse energy dissipation but limited in-plane shear resistance. A novel lightweight constructive system composed of steel columns braced with oriented strand board (OSB panels was conceived and tested. Preliminary laboratory tests were performed to study the OSB-to-column connections with self-drilling screws. Then, the seismic response of a shear wall was determined performing a quasi-static cyclic-loading test of a full-scale specimen. Results presented in this work in terms of force-displacement capacity show that this system confers to shear walls high in-plane strength and stiffness with good ductility and dissipative capacity. Therefore, the incorporation of steel columns within OSB bracing panels results in a strong and stiff platform-frame system with high potential for low- and medium-rise buildings in seismic-prone areas.

  4. Study on application of single-crystal ice `Kurobe ice column` to high-speed skating rinks. Demonstration test result at Olympic memorial arena `M wave` in Nagano city; Tankesshohyo `Kurobe no hyojun` no kosoku skate link eno tekiyosei kenkyu. Naganoshi olympic kinen arina `Emu Wave` deno jissho shiken kekka

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, M. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-06-10

    For high-speed low-friction skating rinks, research was made on sticking artificial ice columns (ice bamboo shoot). The ice columns were fabricated with the ice column production equipment equipped with 4-line water droplet dropping devices which were installed at intervals of 0.3m on both sides of a pathway of 200m long, 2.6m wide and 1.8m high in the lateral adit of Kurobegawa No.4 hydroelectric power station. The grown ice columns were processed for high-speed skating rinks through cutting, confirmation of single crystal and crystal orientation, slicing for every 7mm thickness and packaging. The ice columns were spread all over the rink while sliding them to prevent mixing of bubbles after spraying distilled water of nearly 25 degreesC onto base ices. In addition, hot water of nearly 40 degreesC was sprayed to produce the final ice rink of 30mm thick by nearly 5mm a day. The dynamic friction coefficient of the ice column rink reduced to 0.0038 by nearly 16% as compared with 0.0045 of conventional rinks. (NEDO)

  5. Modular evolution of the Cetacean vertebral column.

    Science.gov (United States)

    Buchholtz, Emily A

    2007-01-01

    Modular theory predicts that hierarchical developmental processes generate hierarchical phenotypic units that are capable of independent modification. The vertebral column is an overtly modular structure, and its rapid phenotypic transformation in cetacean evolution provides a case study for modularity. Terrestrial mammals have five morphologically discrete vertebral series that are now known to be coincident with Hox gene expression patterns. Here, I present the hypothesis that in living Carnivora and Artiodactyla, and by inference in the terrestrial ancestors of whales, the series are themselves components of larger precaudal and caudal modular units. Column morphology in a series of fossil and living whales is used to predict the type and sequence of developmental changes responsible for modification of that ancestral pattern. Developmental innovations inferred include independent meristic additions to the precaudal column in basal archaeocetes and basilosaurids, stepwise homeotic reduction of the sacral series in protocetids, and dissociation of the caudal series into anterior tail and fluke subunits in basilosaurids. The most dramatic change was the novel association of lumbar and anterior caudal vertebrae in a module that crosses the precaudal/caudal boundary. This large unit is defined by shared patterns of vertebral morphology, count, and size in all living whales (Neoceti).

  6. Experimental analysis of reinforced concrete columns strengthened with self-compacting concrete and connectors

    Directory of Open Access Journals (Sweden)

    P. P. Nascimento

    Full Text Available There are many problems involving cases of destruction of buildings and other structures. The columns can deteriorate for several reasons such as the evolution and changing habits of the loads. The experimental phase of this work was based on a test involving nine reinforced concrete columns under combined bending and axial compression, at an initial eccentricity of 60 mm. Two columns were used as reference, one having the original dimensions of the column and the other, monolithic, had been cast along the thickness of the strengthened piece. The remaining columns received a 35 mm thick layer of self-compacting concrete on their compressed face. For the preparation of the interface between the two materials, this surface was scarified and furrowed and connectors were inserted onto the columns' shear reinforcement in various positions and amounts.As connectors, 5 mm diameter steel bars were used (the same as for stirrups, bent in the shape of a "C" with 25 mm coatings. >As a conclusion, not only the quantity, but mainly, the location of the connectors used in the link between substrate and reinforcement is crucial to increase strength and to change failure mode.

  7. Seismic retroftting of RC columns with RC jackets and wing walls with different structural details

    Science.gov (United States)

    Chang, Shuenn-Yih; Chen, Ting-Wei; Tran, Ngoc-Cuong; Liao, Wen-I.

    2014-06-01

    An original reinforced concrete (RC) column and four strengthened specimens, two with RC jackets and two with wing walls, were tested in this study. The original column specimen was designed to comply with older (pre-1999) design standards so that the usual detailing deficiencies in existing school buildings in Taiwan could be simulated. Two different structural details were chosen to fabricate the full-scale specimens for each retrofitting technique. The study confirmed that either RC jacketing or the installation of wing walls with two different structural details can effectively improve the stiffness and strength of an existing column. RC jacketing shows a better improvement in energy dissipation and ductility when compared to the columns with wing walls installed. This is because the two RC jacketed columns experienced a flexural failure, while a shear failure was found in the two columns with the wing walls installed, and thus led to a drastic decrease of the maximum lateral strengths and ductility. Since many factors may affect the installation of a post-installed anchor, it is better to use standard hooks to replace post-installed anchors in some specific points when using RC jacketing or installing wing walls.

  8. Hydrodynamics, mass transfer, and yeast culture performance of a column bioreactor with ejector.

    Science.gov (United States)

    Prokop, A; Janík, P; Sobotka, M; Krumphanzl, V

    1983-04-01

    A bubble column fitted with an ejector has been tested for its physical and biological performance. The axial diffusion coefficient of the liquid phase in the presence of electrolytes and ethanol was measured by a stimulus-response technique with subsequent evaluation by means of a diffusion model. In contrast to ordinary bubble columns, the coefficient of axial mixing is inversely dependent on the superficial air velocity. The liquid velocity acts in an opposite direction to the backmixing flow in the column. The measurement of volumetric oxygen transfer coefficient in the presence of electrolytes and ethanol was performed using a dynamic gassing-in method adapted for a column. The data were correlated with the superficial air and liquid velocities, total power input, and power for aeration and mixing; the economy coefficient of oxygen transfer was used for finding an optimum ratio of power for aeration and pumping. Growth experiments with Candida utilis on ethanol confirmed some of the above results. Biomass productivity of 2.5 g L(-1) h(-1) testifies about a good transfer capability of the column. Columns fitted with pneumatic and/or hydraulic energy input may be promising for aerobic fermentations considering their mass transfer and mixing characteristics.

  9. EX0904 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0904: Water Column Exploration Field...

  10. The effects of load history and design variables on performance limit states of circular bridge columns - volume 2 : experimental observations.

    Science.gov (United States)

    2015-01-01

    This report is the second of three volumes and presents detailed data and test summaries of the experimental portion of the work. In total : 30 large scale reinforced concrete bridge columns are reported in this volume. Recommendations for design and...

  11. The effects of load history and design variables on performance limit states of circular bridge columns - volume 1.

    Science.gov (United States)

    2015-01-01

    This report is the first of three volumes and presents interpretation of all experimental and numerical data and recommendations. In : total, 30 large scale reinforced concrete columns tests were conducted under a variety of loading conditions. Using...

  12. Arsenic removal from water using natural iron mineral-quartz sand columns.

    Science.gov (United States)

    Guo, Huaming; Stüben, Doris; Berner, Zolt

    2007-05-15

    The study has investigated the feasibility of using siderite-coated quartz sand and/or hematite-coated quartz sand columns for removing As from water. Arsenic-spiked tap water and synthetic As solution with As concentrations from 200 to 500 mug/L were used for the experiments. Since three coating methods employed to prepare siderite-coated quartz sand and hematite-coated quartz sand had no significant impact on As adsorption in batch tests, the column fillings were produced by means of the simplest one involving mechanically mixing the Fe mineral with quartz sand. Fixed bed tests show that the combination of siderite-coated quartz sand and hematite-coated quartz sand greatly promoted the column performance in removing As and the presence of As(III) in the influent improved the removal efficiency of the column. The relatively low capacity in treating As-spiked tap water arose from the suppression of FeCO(3) dissolution in the presence of high HCO(3)(-) concentration (333 mg/L), which consequently limited the formation of fresh Fe(III) oxides. However, the H(2)O(2)-conditioning greatly increased As adsorption capacity of the column for remediating As-spiked tap water. The Toxicity Characteristic Leaching Procedure (TCLP) test shows that the spent adsorbents were not hazardous and could be safely disposed of to landfill.

  13. Assessment on Ultimate Load of Cold-formed Steel Channel (CFSC Stub Column

    Directory of Open Access Journals (Sweden)

    Mohd Sani Mohd Syahrul Hisyam

    2015-01-01

    Full Text Available Cold-formed steel is used as the non-structural and structural material in civil engineering work and building. Cold-formed steel channel is selected and cut into 100 mm, 200 mm, 300 mm, 400 mm and 500 mm. The slenderness ratio is calculated and noted as a stub or short column because below 40. The column is tested by using Universal Testing Machine to determine the ultimate load of the stub column. Besides, the CFSC is determined the material properties of CFSC for checking it’s the originality of steel based material. The experimental data are tested and compared with the Direct Strength Method (DSM. It showed that the CFSC1 with a height of 100 mm is reported to have a higher value of ultimate load when compared with other samples. When the height of the stub column increased, the ultimate load of the sample is decreased. Then, the CFSC1 also showed a higher in initial stiffness when compared with other samples. All samples are shown having a higher data in ultimate load when compared with the Direct Strength Method prediction. The ultimate load of experimental and DSM all gave a ratio below 1.03. Finally, all samples can further recommend determining the relation between the ultimate loads with variations of height of the column.

  14. Use of the fluid column in a cardiac catheter for emergency pacing

    OpenAIRE

    Meester, Geert; Simoons, Maarten; Kint, Peter-Paul; Spaa, W.; Slager, Cornelis; Hugenholtz, Paul

    1983-01-01

    textabstractGiven the not infrequent need for intracardiac pacemaking during intensive cardiac care, a new type of cardiac pacemaker has been designed and tested [1]. With this pacemaker the heart can be stimulated through the fluid column of any conventional catheter, provided it is filled with a 0.9% NaCl solution. This fluid column pacemaker (FCP) is of the "constant current" type. The FCP was tested in 37 animals, in 30 patients in sinus rhythm, and also in two critical patients. In addit...

  15. Cross flow flotation column for coal and minerals beneficiation

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Ralph W.; Patton, Robert A.

    1997-12-01

    An apparatus and process are disclosed for the separation of coal from pyritic impurities using a modified froth flotation system. The froth flotation column incorporates a helical track about the inner wall of the column in a region intermediate between the top and base of the column. A standard impeller located about the central axis of the column is used to generate a centrifugal force thereby increasing the separation efficiency of coal from the pyritic particles and hydrophilic tailings.

  16. Numerical Simulations of Settlement of Jet Grouting Columns

    Directory of Open Access Journals (Sweden)

    Juzwa Anna

    2016-03-01

    Full Text Available The paper presents the comparison of results of numerical analyses of interaction between group of jet grouting columns and subsoil. The analyses were conducted for single column and groups of three, seven and nine columns. The simulations are based on experimental research in real scale which were carried out by authors. The final goal for the research is an estimation of an influence of interaction between columns working in a group.

  17. Coal desulfurization by bacterial treatment and column flotation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kawatra, S.K. [Michigan Technological Univ., Houghton, MI (United States)

    1994-06-01

    A review of the literature showed that bacterial leaching, using the microorganism Thiobacillus ferrooxidans, was a very effective technique for removing pyrite from coal, as it could dissolve even the finest pyrite particles without the need for expensive reagents or extreme processing conditions. Unfortunately, bacterial leaching is also rather slow, and so the initial goal of this research was to decrease the leaching time as much as possible. However, this still left the bacteria needing approximately a week to remove half of the pyritic sulfur, and so a faster technique was sought. Since it had been reported in the literature that T. ferrooxidans could be used to depress the flotation of pyrite during froth flotation of coal, this was investigated further. By studying the recovery mechanisms of coal-pyrite in froth flotation, it was found that pyrite was being recovered by entrainment and by locking to coal particles, not by true flotation of hydrophobic pyrite. Therefore, no pyrite depressant could be of any significant benefit for keeping pyrite out of the coal froth product, and it was much more important to prevent entrainment from occurring. Countercurrent flotation columns were invented to essentially eliminate entrainment effects, by washing the froth and reducing mixing of the froth and tailings products. Existing flotation columns tend to be quite simple, and in order to give reasonable product quality they must be very tall (typically 30--45 feet). As a result, they have difficulty in handling the high froth volumes which occur in coal flotation, and are awkward to install in existing plants. The bulk of this project therefore concentrated on developing an improved coal flotation column, and testing it under actual plant conditions.

  18. Simulators of tray distillation columns as tools for interpreting ...

    African Journals Online (AJOL)

    Simulators of tray distillation columns were used to provide technical guidelines for interpreting signals from gamma ray scans used for analysing malfunctions in distillation columns. The transmitted radiation intensities at 0.05 m intervals were determined from top to the bottom of simulators of tray distillation columns ...

  19. Mechanistic model for dispersion coefficients in bubble column

    CSIR Research Space (South Africa)

    Skosana, PJ

    2015-05-01

    Full Text Available A mechanistic model describing the mass and momentum exchange in bubble columns is proposed that is based on the observations that the gas distribution in a bubble column is not uniform across the column and that as a consequence large liquid...

  20. Partial Path Column Generation for the Vehicle Routing Problem

    DEFF Research Database (Denmark)

    Jepsen, Mads Kehlet; Petersen, Bjørn

    This paper presents a column generation algorithm for the Capacitated Vehicle Routing Problem (CVRP) and the Vehicle Routing Problem with Time Windows (VRPTW). Traditionally, column generation models of the CVRP and VRPTW have consisted of a Set Partitioning master problem with each column...

  1. Influence of steel fibres on the blast response of normal-strength and high-strength reinforced concrete columns

    Science.gov (United States)

    Hammoud, A.; Aoude, H.

    2017-09-01

    This paper examines the influence of steel fibres on the blast performance of normal-strength concrete and high-strength concrete columns. As part of the study, four normal-strength and high-strength concrete columns built with and without steel fibres are tested under simulated blast loads using the shock-tube facility at the University of Ottawa. The specimens include two columns built with plain concrete and two columns built with steel fibre-reinforced concrete. The results show that the addition of steel fibres in reinforced concrete columns leads to important enhancements in blast performance, with improved control of mid-span displacements at equivalent blasts and increased damage tolerance.

  2. Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN

    Energy Technology Data Exchange (ETDEWEB)

    Greenhalgh, Mitchell Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Garn, Troy Gerry [Idaho National Lab. (INL), Idaho Falls, ID (United States); Welty, Amy Keil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Watson, Tony Leroy [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to perform this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.

  3. Silica-based monolithic capillary columns-Effect of preparation temperature on separation efficiency.

    Science.gov (United States)

    Planeta, Josef; Moravcová, Dana; Roth, Michal; Karásek, Pavel; Kahle, Vladislav

    2010-09-03

    The temperature effects during the sol-gel process and ageing of the silica-based monolith on the structure and separation efficiency of the capillary columns (100microm i.d., 150mm) for HPLC separations were studied. The tested columns were synthesized from a mixture of tetramethoxysilane, polyethylene glycol and urea under the acidic conditions. The temperature was varied from 40 degrees C to 44 degrees C and formation of bypass channels between the silica mold and the capillary wall was examined. The temperature of 43 degrees C was estimated as optimal for preparation of efficient silica capillary columns which were subsequently modified by octadecyldimethyl-N,N-diethylaminosilane or covered by poly(octadecyl methacrylate) and tested using standard mixture of alkylbenzenes under the isocratic conditions. 2010 Elsevier B.V. All rights reserved.

  4. Column subset selection is NP-complete

    OpenAIRE

    Shitov, Yaroslav

    2017-01-01

    Let $M$ be a real $r\\times c$ matrix and let $k$ be a positive integer. In the column subset selection problem (CSSP), we need to minimize the quantity $\\|M-SA\\|$, where $A$ can be an arbitrary $k\\times c$ matrix, and $S$ runs over all $r\\times k$ submatrices of $M$. This problem and its applications in numerical linear algebra are being discussed for several decades, but its algorithmic complexity remained an open issue. We show that CSSP is NP-complete.

  5. Preinjector for Linac 1, accelerating column

    CERN Multimedia

    1974-01-01

    For a description of the Linac 1 preinjector, please see first 7403070X. High up on the wall of the Faraday cage (7403073X) is this drum-shaped container of the ion source (7403083X). It is mounted at the HV end of the accelerating column through which the ions (usually protons; many other types of ions in the course of its long history) proceed through the Faraday cage wall to the low-energy end (at ground potential) of Linac 1. The 520 kV accelerating voltage was supplied by a SAMES generator (7403074X).

  6. Investigation of Axial Strengthened Reinforced Concrete Columns under Lateral Blast Loading

    Directory of Open Access Journals (Sweden)

    Mohammad Esmaeilnia Omran

    2017-01-01

    Full Text Available Different factors can affect blast response of structural components. Hence, experimental tests could be the best method for evaluating structures under blast loading. Therefore, an experimental explosion loading has been done on RC members by the authors. Four RC components, with identical geometry and material, with and without axial load were imposed to air blast. Observed data of the members’ response under blast loading was used for validation of finite element modeling process using ABAQUS software. With respect to complexity, limitations, and high costs of experimental tests, analytical studies and software modeling can be good alternatives. Accordingly, in this paper, the behavior of 6 different models of normal and strengthened RC columns under blast loading was evaluated using ABAQUS. Strengthening configurations considered here were designed for enhancing axial capacity of RC columns. Therefore, we can investigate the effectiveness of axial strengthening of column on its blast resistance capacity and residual axial strength. The considered strengthening methods were different steel jacket configurations including steel angle, channel, and plate sections. The results showed that retrofitting significantly improves blast performance of the columns. Moreover, residual strength capacity of the columns strengthened with steel channel is higher than the other models.

  7. Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model.

    Directory of Open Access Journals (Sweden)

    Ibrahim Ben Daya

    Full Text Available 3-D ultrasound imaging offers unique opportunities in the field of non destructive testing that cannot be easily found in A-mode and B-mode images. To acquire a 3-D ultrasound image without a mechanically moving transducer, a 2-D array can be used. The row column technique is preferred over a fully addressed 2-D array as it requires a significantly lower number of interconnections. Recent advances in 3-D row-column ultrasound imaging systems were largely focused on sensor design. However, these imaging systems face three intrinsic challenges that cannot be addressed by improving sensor design alone: speckle noise, sparsity of data in the imaged volume, and the spatially dependent point spread function of the imaging system. In this paper, we propose a compensated row-column ultrasound image reconstruction system using Fisher-Tippett multilayered conditional random field model. Tests carried out on both simulated and real row-column ultrasound images show the effectiveness of our proposed system as opposed to other published systems. Visual assessment of the results show our proposed system's potential at preserving detail and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal to Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  8. Effects of a nearshore wastewater discharge: Water column and sediment pore water toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Krause, P.R. [MEC Analytical Systems, Inc., Tiburon, CA (United States); Carr, R.S. [National Biological Survey, Corpus Christi, TX (United States)

    1995-12-31

    The relationship between water column and sediment pore water toxicity was investigated near a municipal-industrial wastewater discharge in southern Texas. Toxicity associated with effluent distributions in the water column are known to vary in both time and space. Toxicity of sediment, however, is often more stable over time. Sediment can serve as a long-term integrator of toxicity in areas subject to chronic exposure of effluents. This study addressed the relationship between water column toxicity and that found in the sediments on both spatial and temporal scales. Four 2 Km transacts were established around a nearshore wastewater outfall. Eight stations along each transact were sampled for both surface waters and sediment pore water toxicity. Toxicity was determined using a modified sea urchin fertilization test. Surface waters were sampled and tested for eight consecutive months, while sediment pore waters were sampled on three occasions over the length of this study. Results have shown that toxicity in receiving waters was a good indicator to trace movements of the highly variable effluent plume. The distribution of effluent in the water column, and hence water column toxicity, was primarily driven by local wind conditions. Toxicity in sediment porewater was, much less variable and more evenly distributed over the study site. Sediment pore water toxicity was also a good predictor of the distribution of benthic infaunal invertebrates over much of the study site.

  9. Behaviour of wrapped cold-formed steel columns under different loading conditions

    Science.gov (United States)

    Baabu, B. Hari; Sreenath, S.

    2017-07-01

    The use of Cold Formed Steel (CFS) sections as structural members is widely accepted because of its light nature. However, the load carrying capacity of these sections will be less compared to hot rolled sections. This study is meant to analyze the possibility of strengthening cold formed members by wrapping it with Glass Fiber Reinforced Polymer (GFRP) laminates. Light gauge steel columns of cross sectional dimensions 100mm x 50mm x 3.15mm were taken for this study. The effective length of the section is about 750mm. A total of 8 specimens including the control specimen is tested under axial and eccentric loading. The columns were tested keeping both ends hinged. For both loading cases the buckling behaviour, ultimate load carrying capacity and load-deflection characteristics of the CFS columns were analyzed. The GFRP laminates were wrapped on columns in three different ways such that wrapping the outer surface of web and flange throughout the length of specimen, wrapping the outer surface of web alone throughout the length of specimen and wrapping the outer surface of web and flange for the upper half length of the specimen where the buckling is expected. For both loading cases, the results indicated that the column with wrapping at the outer surface of web and flange throughout the length of specimen provides better strength for it.

  10. In-series columns adsorption performance of Kraft mill wastewater pollutants onto volcanic soil.

    Science.gov (United States)

    Navia, R; Fuentes, B; Lorber, K E; Mora, M L; Diez, M C

    2005-08-01

    Two in-series columns systems with volcanic soil were tested for wastewater pollutants adsorption capacity. The first system was tested with acidified volcanic soil and the second with a reactivated volcanic soil. The reactivated soil was obtained by washing the previous spent acidified soil system with an acid solution. The systems parameters were obtained using the Bohardt and Adams model for fixed-beds. The acidified soil parameters indicated an adsorption capacity q of 28 and 139 mg/g of phenolic compounds and color, respectively (for each column), compared to 12 and 39 mg/g for the reactivated soil system. The adsorption rate constant k ranged between 1.5x10(-6) and 2.8x10(-6) l/min mg and no significant difference was observed for each analysed column system and pollutant. Furthermore, the molecular weight distribution analysis of input and output samples of one acidified soil column indicated that the fraction >30000 Da is the most adsorbed until the breakpoint. Moreover, the CODs and tannins and lignin removal efficiencies at the breakpoint reached values between 60% and 70% in each column and each system, indicating that lower biodegradable compounds were retained effectively. The results indicate that it is possible to compare the acidified volcanic soil adsorption capacity with natural zeolites, and a preliminary costs evaluation indicates that volcanic soil could be also competitive, even when comparing with activated carbon.

  11. Research on Configurations of Thermally Integrated Distillation Column(TIDC)

    Science.gov (United States)

    Sun, Lanyi; Li, Jun; Liu, Xuenuan; Li, Qingsong

    Taking a C3 distillation column as the base case, possible configurations for Thermally Integrated Distillation Columns (TIDC) are proposed and compared to a conventional column and a column with a vapor recompression system (VRC). Thermal efficiency of the TIDC appears to be strongly sensitive to column configuration and a highly efficient asymmetrical configuration with stripping section stages thermally interconnected with the same number of stages in the upper part of the rectifying section emerges as the most promising option. The relationships among pressure ratio of rectifying section to stripping section and energy consumption were also discussed.

  12. Observations of iodine monoxide columns from satellite

    Directory of Open Access Journals (Sweden)

    A. Schönhardt

    2008-02-01

    Full Text Available Iodine species in the troposphere are linked to ozone depletion and new particle formation. In this study, a full year of iodine monoxide (IO columns retrieved from measurements of the SCIAMACHY satellite instrument is presented, coupled with a discussion of their uncertainties and the detection limits. The largest amounts of IO are found near springtime in the Antarctic. A seasonal variation of iodine monoxide in Antarctica is revealed with high values in springtime, slightly less IO in the summer period and again larger amounts in autumn. In winter, no elevated IO levels are found in the areas accessible to satellite measurements. This seasonal cycle is in good agreement with recent ground-based measurements in Antarctica. In the Arctic region, no elevated IO levels were found in the period analysed. This implies that different conditions with respect to iodine release exist in the two Polar Regions. To investigate possible release mechanisms, comparisons of IO columns with those of tropospheric BrO, and ice coverage are described and discussed. Some parallels and interesting differences between IO and BrO temporal and spatial distributions are identified. Overall, the large spatial coverage of satellite retrieved IO data and the availability of a long-term dataset provide new insight about the abundances and distributions of iodine compounds in the troposphere.

  13. Axial and Flexural Strength of Square RC Columns with No-rounded Corners Wrapped with CFRP under Eccentric Loading

    Directory of Open Access Journals (Sweden)

    Ade Lisantono

    2018-01-01

    Full Text Available This paper presents the results of a study on the axial and flexural strength of reinforced concrete (RC columns with no-rounded corners wrapped with Carbon Fiber Reinforced Polymer (CFRP under eccentric loading based on an experimental program. The main parameters under investigation are the number of layers of CFRP wrap. Thirty-six concrete cylinders with a standard size of (150×300 mm were cast and tested in this study to get the modulus of elasticity and compressive strength of concrete. Of these 36 concrete cylinders were divided into four groups, unwrapped, wrapped with one layer of CFRP, wrapped with two layers of CFRP, and wrapped with three layers of CFRP. Twelve rectangular reinforced concrete columns were also cast and tested in this study.  The column specimens had dimensions (75×75×750 mm with no-rounded corners of the column section.  The column specimens were also divided into four groups, unwrapped, wrapped with one layer of CFRP, wrapped with two layers of CFRP, and wrapped with three layers of CFRP. The experiment results show that the load-carrying capacity of the wrapped column increased by the increasing number of CFRP layers. Comparing the experimental results with the compressive strength concrete and the maximum load-carrying capacity of wrapped RC Column predicted by the theories proposed by several researchers with the concern of no-rounded corners were also presented.

  14. Study of clean up procedures using Charcoal-Alumina-Celite column, immunoaffinity column and strata x column to determine deoxynivalenol by high performance liquid chromatography in wheat

    Directory of Open Access Journals (Sweden)

    Jacqueline Cea

    2011-04-01

    Full Text Available Fusarium graminearum is the most common toxic fungal species affecting grains in Uruguay. Since 1977, due to favorable climate conditions, there have been harvests with prominent Fusarium Head Blight in wheat. This were in 1984, 1990, 1993, 1996 and 2001.Natural Toxin Department of Technological Laboratory of Uruguay as National Reference Laboratory, is continuously improving the analytical methods in order to have a good response to the industry requirements and to the monitoring programs for import and exports commodities. The objective of this work was to compare different clean up methods in order to select the best one for routine determination of deoxynivalenol (DON in wheat (grain and flour.  Charcoal-alumina-celite (7+5+3,  immunoaffinity columns DONPREP R-Biopharm Rhone and Strata X 33 m polymeric sorbent  Phenomenex columns were used to perform the study. Considering as reference analytical method the internal protocol  PEC.TOX.063 accredited by United Kingdom Accreditation Service (UKAS  following the ISO 17025 requirements, and  based on AOAC method 986.17( chapter 49, 2002 for extraction and clean-up  and on J.AOAC 70(3, 1987:479-483 for the high performance liquid chromatography (HPLC detection, two more clean up methods were evaluated. In all of them PEC.TOX.063 detection procedure was carried out. PEC.TOX.063 used for the clean up an in house column chromatography prepared with charcoal-alumina-celite (7+5+3 . Extraction was performed using acetonitrile- water (84+16 and an aliquot of the extract was passed through the column. Extract was dryed under vacuum and DON detected by HPLC using photodiode array detector. For the method that used immunoaffinity columns, water was the extraction solvent, and manufacture protocol was followed up. An aliquot of the extract was passed through the column. Column was washed using water and DON eluated using methanol 100%. For the method that used Strata X column for the clean up, the

  15. Monocytes and macrophages form branched cell columns in matrigel: implications for a role in neovascularization.

    Science.gov (United States)

    Anghelina, Mirela; Krishnan, Padma; Moldovan, Leni; Moldovan, Nicanor I

    2004-12-01

    Linear arrays of cells, or cell columns, have been observed in the extracellular matrix prior to neovascularization, but their nature and significance remains elusive. Based on the emerging evidence implicating a role for monocytes and macrophages (MC/MPH) in vasculogenesis, we hypothesized that MC/MPH also can form linear or branched columns, facilitating the co-migration and the spatial arrangement of other cell types. To test this hypothesis, we studied the distribution of MC/MPH effected by chemotactic migration in novel in vitro and in vivo models of development. We induced transversal and lateral migration of THP-1 monocytoid cells in Matrigel in vitro. The effect of this process on co-localization of other micro-objects was assessed using erythrocytes and micron-sized plastic beads. In vivo, we analyzed MC/MPH infiltration in subcutaneously implanted Matrigel plugs containing angiogenic factors and across a microporous filter comprising the wall of a chamber filled with Matrigel, also placed subcutaneously in mice. In vitro, we found that migrating THP-1 cells induced the lasting degradation of Matrigel and produced cell columns, a process amplified by monocyte chemoattractant protein-1 (MCP-1). We also report the co-localization of erythrocytes with THP-1 cells in cell columns. Endothelium-free tunnels containing MC/MPH, neutrophils, or erythrocytes were also observed in the Matrigel-filled chambers. In free subcutaneous Matrigel plugs, we found MC/MPH-based columns harboring isolated Tie-2+ cells (a marker of endothelial progenitor phenotype), as well as fibroblasts, dendritic cells, and adypocytes. Many of these cell columns displayed conspicuous branching. Our data demonstrate formation of branched MC/MPH cell columns in vitro and in vivo, a previously unrecognized pattern of penetration of extracellular matrices by inflammatory cells. Thus, monocytes and macrophages influence the distribution of neovessels as well as their branching points. These cells

  16. Total column ozone retrieval using INSAT-3D sounder in the tropics ...

    Indian Academy of Sciences (India)

    The present study examines the potential of infrared sounder observations from Indian geostationary satellite INSAT-3D for the estimation of total column integrated ozone over the tropical Indian region. A dataset with diverse profiles was used to create training and testing datasets using forward simulations from a radiative ...

  17. Use of the fluid column in a cardiac catheter for emergency pacing

    NARCIS (Netherlands)

    G.T. Meester (Geert); M.L. Simoons (Maarten); P-P. Kint (Peter-Paul); W. Spaa; C.J. Slager (Cornelis); P.G. Hugenholtz (Paul)

    1983-01-01

    textabstractGiven the not infrequent need for intracardiac pacemaking during intensive cardiac care, a new type of cardiac pacemaker has been designed and tested [1]. With this pacemaker the heart can be stimulated through the fluid column of any conventional catheter, provided it is filled with a

  18. Conventional and enantioselective gas chromatography with microfabricated planar columns for analysis of real-world samples of plant volatile fraction.

    Science.gov (United States)

    Cagliero, C; Galli, S; Galli, M; Elmi, I; Belluce, M; Zampolli, S; Sgorbini, B; Rubiolo, P; Bicchi, C

    2016-01-15

    Within a project exploring the application of lab-on-chip GC to in-field analysis of the plant volatile fraction, this study evaluated the performance of a set of planar columns (also known as microchannels, MEMS columns, or microfabricated columns) of different dimensions installed in a conventional GC unit. Circular double-spiral-shaped-channel planar columns with different square/rectangular sections up to 2m long were applied to the analysis of both essential oils and headspace samples of a group of medicinal and aromatic plants (chamomile, peppermint, sage, rosemary, lavender and bergamot) and of standard mixtures of related compounds; the results were compared to those obtained with reference narrow-bore columns (l:5m, dc:0.1mm, df:0.1 μm). The above essential oils and headspaces were first analyzed quali-and quantitatively with planar columns statically coated with conventional stationary phases (5%-phenyl-polymethylsiloxane and auto-bondable nitroterephthalic-acid-modified polyethylene glycol), and then submitted to chiral recognition of their diagnostic markers, by enantioselective GC with a planar columns coated with a cyclodextrin derivative (30% 6(I-VII)-O-TBDMS-3(I-VII)-O-ethyl-2(I-VII)-O-ethyl-β-cyclodextrin in PS-086). Column characteristics and analysis conditions were first optimized to obtain suitable retention and efficiency for the samples investigated. The planar columns tested showed performances close to the reference conventional narrow-bore columns, with theoretical plate numbers per meter (N/m) ranging from 6100 to 7200 for those coated with the conventional stationary phases, and above 5600 for those with the chiral selector. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Numerical simulation of the low-cyclic loading of new-type assembled integral beam-column joints

    Science.gov (United States)

    Wu, Jiangchuan; Zhang, Jiwen; Yin, Wanyun; Jin, Rencai

    2017-04-01

    In this paper, the low-cycle cyclic loading test and the elasto-plastic numerical simulation by OpenSEES of assembled integral beam-column joints of the three new prefabricated prestressed concrete beams are carried out. The key technologies such as unit selection, material model selection and prestressing in the numerical simulation of the new assembly-type beam-column joint is studied deeply. The results show that the relative model and parameters of the OpenSEES software can be used to simulate the hysteresis performance of the low-cycle cyclic loading of the new-type assembled integral beam-column joints.

  20. Shear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading

    OpenAIRE

    Feng, Bo; Xiong, Feng; Liu, Bingyu; Chen, Jiang; Zhang, Yiping

    2016-01-01

    In this study, two short precast concrete columns and two cast-in-situ concrete columns were tested under cyclic loads. It was shown that the sleeve grouted connection was equivalent to the cast-in-situ connections for short columns when the axial compression ratio was 0.6. In order to determine the influence of the axial compression ratio and the shear-span ratio on the shear capacity of the horizontal joint, a FE model was established and verified. The analysis showed that the axial compres...

  1. Comparative efficiency analysis of different nonlinear modelling strategies to simulate the biaxial response of RC columns

    Science.gov (United States)

    Rodrigues, Hugo; Varum, Humberto; Arêde, António; Costa, Aníbal

    2012-12-01

    The performance of different nonlinear modelling strategies to simulate the response of RC columns subjected to axial load combined with cyclic biaxial horizontal loading is compared. The models studied are classified into two categories according to the nonlinearity distribution assumed in the elements: lumped-plasticity and distributed inelasticity. For this study, results of tests on 24 columns subjected to cyclic uniaxial and biaxial lateral displacements were numerically reproduced. The analyses show that the global envelope response is satisfactorily represented with the three modelling strategies, but significant differences were found in the strength degradation for higher drift demands and energy dissipation.

  2. Behavior of partially defected R.C columns strengthened using steel jackets

    Directory of Open Access Journals (Sweden)

    Ahmed Shaban Abdel-Hay

    2015-08-01

    The main parameters studied were the type of steel jacket used and height of partial strengthened part of column. One of the tested specimens was a control specimen and the other six were partially strengthened with different types of steel jackets such as using 4 steel angles at corners connected with straps, using external ties with different spacings, and using 4 steel plates with different thicknesses welded together and connected to column by anchor bolts. Finally, the experimental results were analyzed and compared with results obtained from finite element analysis using ANSYS program.

  3. Refreshment topics II: Design of distillation columns

    Directory of Open Access Journals (Sweden)

    Milojević Svetomir

    2006-01-01

    Full Text Available For distillation column design it is necessary to define all the variable parameters such as component concentrations in different streams temperatures, pressures, mass and energy flow, which are used to represent the separation process of some specific system. They are related to each other according to specific laws, and if the number of such parameters exceeds the number of their relationships, in order to solve a problem some of them must be specified in advance or some constraints assumed for the mass balance, the balance of energy, phase equilibria or chemical equilibria. Knowledge of specific elements which are the constituents of a distillation unit must be known to define the number of design parameters as well as some additional apparati also necessary to realize the distilation. Each separate apparatus might be designed and constructed only if all the necessary and variable parameters for such a unit are defined. This is the right route to solve a distilation unit in many different cases. The construction of some distillation unit requires very good knowledge of mass, heat and momentum transfer phenomena. Moreover, the designer needs to know which kind of apparatus will be used in the distillation unit to realize a specific production process. The most complicated apparatus in a rectification unit is the distillation column. Depending on the complexity of the separation process one, two or more columns are often used. Additional equipment are heat exchangers (reboilers, condensers, cooling systems, heaters, separators, tanks for reflux distribution, tanks and pumps for feed transportation, etc. Such equipment is connected by pipes and valves, and for the normal operation of a distillation unit other instruments for measuring the flow rate, temperature and pressure are also required. Problems which might arise during the determination and selection of such apparati and their number requires knowledge of the specific systems which must

  4. Vertebral column resection in children with neuromuscular spine deformity.

    Science.gov (United States)

    Sponseller, Paul D; Jain, Amit; Lenke, Lawrence G; Shah, Suken A; Sucato, Daniel J; Emans, John B; Newton, Peter O

    2012-05-15

    Retrospective analysis. To determine, in pediatric patients with neuromuscular deformity undergoing vertebral column resection (VCR), the (1) characteristics of the surgery performed; (2) amount of pelvic obliquity restoration, and coronal and sagittal correction achieved; (3) associated blood loss and complications; and (4) extent to which curve type and VCR approach influenced correction, blood loss, and complications. VCR allows for correction of severe, rigid spinal deformity. This technique has not been previously reported in children with neuromuscular disorders. We retrospectively reviewed the records of 23 children with neuromuscular disorders (mean age, 15 years) and spinal deformities (severe scoliosis, 9; global kyphosis or angular kyphosis, 4; kyphoscoliosis, 10) who underwent VCR. The Student t test was used to compare correction differences (statistical significance, P deformity. However, this challenging procedure involves the potential for major complications.

  5. Hydrodynamic analysis of oscillating water column wave energy devices

    DEFF Research Database (Denmark)

    Bingham, Harry B.; Ducasse, Damien; Nielsen, Kim

    2015-01-01

    A 40-chamber I-Beam attenuator-type, oscillating water column, wave energy converter is analyzed numerically based on linearized potential flow theory, and experimentally via model test experiments. The high-order panel method WAMIT by Newman and Lee (WAMIT; a radiation–diffraction panel program...... for wave-body interactions, 2014, http://​www.​wamit.​com) is used for the basic wave-structure interaction analysis. The damping applied to each chamber by the power take off is modeled in the experiment by forcing the air through a hole with an area of about 1 % of the chamber water surface area....... In the numerical model, this damping is modeled by an equivalent linearized damping coefficient which extracts the same amount of energy over one cycle as the experimentally measured quadratic damping coefficient. The pressure in each chamber in regular waves of three different height-to-length ratios is measured...

  6. Enhanced reductive dechlorination in columns treated with edible oil emulsion

    Science.gov (United States)

    Long, Cameron M.; Borden, Robert C.

    2006-09-01

    The effect of edible oil emulsion treatment on enhanced reductive dechlorination was evaluated in a 14 month laboratory column study. Experimental treatments included: (1) emulsified soybean oil and dilute HCl to inhibit biological activity; (2) emulsified oil only; (3) emulsified oil and anaerobic digester sludge; and (4) continuously feeding soluble substrate. A single application of emulsified oil was effective in generating strongly reducing, anaerobic conditions for over 14 months. PCE was rapidly reduced to cis-DCE in all three live columns. Bioaugmentation with a halorespiring enrichment culture resulted in complete dechlorination of PCE to ethene in the soluble substrate column (yeast extract and lactate). However, an additional treatment with a pulse of yeast extract and bioaugmentation culture was required to stimulate complete dechlorination in the emulsion treated columns. Once the dechlorinating population was established, the emulsion only column degraded PCE from 90-120 μM to below detection with concurrent ethene production in a 33 day contact time. The lower biodegradation rates in the emulsion treated columns compared to the soluble substrate column suggest that emulsified oil barriers may require a somewhat longer contact time for effective treatment. In the HCl inhibited column, partitioning of PCE to the retained oil substantially delayed PCE breakthrough. However, reduction of PCE to more soluble degradation products ( cis-DCE, VC and ethene) greatly reduced the impact of oil-water partitioning in live columns. There was only a small decline in the hydraulic conductivity ( K) of column #1 (low pH + emulsion, Kfinal/ Kinitial = 0.57) and column #2 (live + emulsion, Kfinal/ Kinitial = 0.73) indicating emulsion injection did not result in appreciable clogging of the clayey sand. However, K loss was greater in column #3 (sludge +emulsion, Kfinal/ Kinitial = 0.12) and column #4 (soluble substrate, Kfinal/ Kinitial = 0.03) indicating clogging due

  7. The influence of connecting pile cap-column in the mechanisms of break in the two pile caps

    Directory of Open Access Journals (Sweden)

    A. C. MESQUITA

    Full Text Available Abstract The paper analyzes the two pile caps with partially embedded socket and subject a center load. Three models were experimentally tested, varying the type of conformation of the column and walls of the socket, with a smooth, the other rough, and a monolithic two pile cap, used for reference. The roughening of the column-socket interface was examined with the aim of verifying the difference of the distribution of compressive and tensile stresses in the strut an tie model used for design. The experimental test to show that the two pile caps with conformation rough of the column and walls of the socket, support more load in comparison with two pile caps with smooth of the column and walls of the socket. Both however underperformed the monolithic two pile cap, with values of 66% and 36% respectively.

  8. Behavior of Damaged Exterior RC Beam-Column Joints Strengthened by CFRP Composites

    Directory of Open Access Journals (Sweden)

    Ebrahim Zamani Beydokhty

    Full Text Available Abstract This paper presents an experimental investigation on the behavior of retrofitted beam-column joints subjected to reversed cyclic loading. The experimental program comprises 8 external beam-column joint connection subassemblages tested in 2 phases; one was the damaging phase and second was the repairing phase. The Beam-column joints were designed only for gravity loads. The joints had no beam-column joint transverse reinforcement and special stirrups in beam and column critical zones. These Non-Seismically designed (NS joints were damaged with different levels at the first phase of the experiment. In the second phase, the damaged joints were strengthened with externally bonded carbon-fibre-reinforced polymers (C-FRP sheets. From the observed responses of the examined specimens it can be deduced that the technique of externally bonded retrofitting (EBR using C-FRP sheets is appropriate for the rehabilitation of the joints seismic capacity. This technique had a significant improvement of the energy dissipation and the performance level and finally it leads to improved type of damages compared with the damage modes of the specimens during the initial loading. Shortcomings of the application of C-FRP sheets for practical use are also pointed out.

  9. Review of design codes of concrete encased steel short columns under axial compression

    Directory of Open Access Journals (Sweden)

    K.Z. Soliman

    2013-08-01

    Full Text Available In recent years, the use of encased steel concrete columns has been increased significantly in medium-rise or high-rise buildings. The aim of the present investigation is to assess experimentally the current methods and codes for evaluating the ultimate load behavior of concrete encased steel short columns. The current state of design provisions for composite columns from the Egyptian codes ECP203-2007 and ECP-SC-LRFD-2012, as well as, American Institute of Steel Construction, AISC-LRFD-2010, American Concrete Institute, ACI-318-2008, and British Standard BS-5400-5 was reviewed. The axial capacity portion of both the encased steel section and the concrete section was also studied according to the previously mentioned codes. Ten encased steel concrete columns have been investigated experimentally to study the effect of concrete confinement and different types of encased steel sections. The measured axial capacity of the tested ten composite columns was compared with the values calculated by the above mentioned codes. It is concluded that non-negligible discrepancies exist between codes and the experimental results as the confinement effect was not considered in predicting both the strength and ductility of concrete. The confining effect was obviously influenced by the shape of the encased steel section. The tube-shaped steel section leads to better confinement than the SIB section. Among the used codes, the ECP-SC-LRFD-2012 led to the most conservative results.

  10. Bridged polysilsesquioxane-based wide-bore monolithic capillary columns for hydrophilic interaction chromatography.

    Science.gov (United States)

    Šesták, Jozef; Moravcová, Dana; Křenková, Jana; Planeta, Josef; Roth, Michal; Foret, František

    2017-01-06

    The synthesis and characterization of large-bore silica-based monolithic capillary columns (0.32mm×150mm) are presented. Columns were prepared by acidic hydrolysis of a mixture containing tetramethoxysilane (TMOS) and 1,2-bis(trimethoxysilyl)ethane (BTME) in different molar ratios in the presence of polyethylene glycol and urea. The monoliths were modified by zwitterionic monomer [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl)-ammonium hydroxide via 3-(trimethoxysilyl)propyl methacrylate. Prepared stationary phases were evaluated by scanning electron microscopy and chromatographic separation of nucleobases and their derivatives in the HILIC mode. The best chromatographic results were obtained with the column prepared from the reaction mixture containing BTME and TMOS in a 1:4 molar ratio. The permeability of such column reached 1.68×10(-14)m(2) and the efficiency, expressed as a height equivalent of the theoretical plate, did not exceed 10.5μm for the tested compounds. The columns were successfully applied to HILIC separation of native and labeled oligosaccharides and glycans released from bovine ribonuclease B and human immunoglobulin G. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Removal of phosphorus from water by using volcanic ash soil (VAS): batch and column experiments.

    Science.gov (United States)

    Nguyen, Huy Van; Maeda, Morihiro

    2016-09-01

    Using low-cost and naturally available materials is considered an optimal adsorbent for removing phosphorus (P) from water due to its simplicity and economic efficiency. This study examined the removal of P from water using volcanic ash soil (VAS) by batch and column experiments. The maximum adsorption capacity of P was 2.94 mg g -1 , estimated from the batch experiment according to a Langmuir isotherm. The column study showed a higher adsorption capacity of 5.57 mg g -1 . The breakthrough curve showed that influent water containing 2 mg L -1 P was completely purified by VAS within 1,230 pore volumes (PV). The breakthrough and saturation points of the curves were 3,100 PV and 14,875 PV, respectively. After an adsorption column was loaded with 20,508 PV, a regeneration procedure was developed to determine whether an ion exchange of P with chloride occurred or adsorbed P in the columns could be eluted. Approximately 20% of P was recovered from columns by desorption tests, regardless of NaCl solution or deionized water. Specific surface area and mineral concentrations are both important characteristics that improve the adsorption capacity of VAS. The present study suggests that VAS is a promising adsorbent to remove P in water.

  12. Vortex Counter-Current Chromatography: Performance of a New Preparative Column.

    Science.gov (United States)

    Ito, Yoichiro; Clary, Robert; Witten, Jacob J; Zeng, Yun

    2012-10-01

    A New preparative column for the vortex counter-current chromatograph was fabricated by making many (966) cylindrical separation units to a high-dendity polyethylene disk and thenthreading them with 6-40 taps. The resulting column had a total capacity of 364 mL. The performance of this vortex column was examined with three different two-phase solvent systems each using a set of suitable test samples: hexane-ethyl acetate-methanol-0.1 M hydrochloric acid (1:1:1:1, v/v) for separation of DNP-amino acids; 1-butanol-acetic acid-water (4:1:5, v/v) for separation of dipeptides; and hexane-acetonitrile-water (20:15:2, v/v) for separation of Sudan dyes. Most of the separations show high partition efficiency of over a thousand theoretical plates, as expected based on the results previously obtained in preliminary separations with a small column. Overall, the results of the present study suggest that further improvement of the partition efficiency can be obtained by the modifying column configuration.

  13. In situ extraction versus the use of an external column in fermentation

    Energy Technology Data Exchange (ETDEWEB)

    Eiteman, M.A.; Gainer, J.L.

    1989-06-01

    Organic extraction of 2,3-butanediol produced by Klebsiella oxytoca fermentation was studied to determine if the use of an external column offered advantages over in situ extractive fermentation. Dodecanol was chosen from 24 tested solvents, 11 of which were non-toxic to K. oxytoca. Although growth occurred in all shakeflask experiments containing dodecanol, growth was never observed when dodecanol was used in an in situ arrangement in a fermentor. Using dodecanol in an external column, however, resulted in a cell yield of 0.10 g/g D-xylose, and a 2,3-butanediol yield of 0.32 g/g D-xylose, similar to results obtained in control (solventless) experiments. Although the partitioning of 2,3-butanediol in the organic phase was low, this study suggests that external columns, with recycling to the fermentor, can offer substantial advantages over in situ extraction.

  14. FREQUENCY AND STRUCTURE OF SAGITTAL DISORDERS OF THE SPINAL COLUMN WIEH ADOLESCENT STUDENTS

    Directory of Open Access Journals (Sweden)

    Veselin Jovović

    2010-09-01

    Full Text Available The state and the status of the spinal column in the profile plane are established among 511 tested, both sexes. the sample is found among the pupil population of seventh class of the primary school, from the territory of Podgorica and Nikšić. Estimate of the state cyfosa and lordosa is subjugated to combinative methods and techniques of measuring, attractive for more extensive and masser questionings in school conditions. It is shows by research that the deviations of the spinal column in the profile plane are present in considerable percent among adolescent age pupils in Nontenegro. Far the biggest percent of the spinal column devations in the profile plane are easier forms of disoders reductive disorders which can be corrected bu the use of definite steps.

  15. Mechanical behavior of confined self-compacting reinforced concrete circular columns under concentric axial loading

    Directory of Open Access Journals (Sweden)

    Fouad Khairallah

    2013-12-01

    Full Text Available While there is abundant research information on ordinary confined concrete, there are little data on the behavior of Self-Compacting Concrete (SCC under such condition. Due to higher shrinkage and lower coarse aggregate content of SCC compared to that of Normal Concrete (NC, its composite performance under confined conditions needs more investigation. This paper has been devoted to investigate and compare the mechanical behavior of confined concrete circular columns cast with SCC and NC under concentric axial loading. The parameters affecting are including concrete compressive strength and confinement configuration. Twenty column specimens were casted and confined using four confinement techniques, CFRP wrap, FRP tube, GFRP wrap, and spiral steel hoops. The performance of the tested column specimens is evaluated based on mode of failure, load–displacement curve, stress–strain characteristics, ultimate strength, ductility, and degree of confinement.

  16. Prediction of shear critical behavior of high-strength reinforced concrete columns using finite element methods

    Science.gov (United States)

    Alrasyid, Harun; Safi, Fahrudin; Iranata, Data; Chen-Ou, Yu

    2017-11-01

    This research shows the prediction of shear behavior of High-Strength Reinforced Concrete Columns using Finite-Element Method. The experimental data of nine half scale high-strength reinforced concrete were selected. These columns using specified concrete compressive strength of 70 MPa, specified yield strength of longitudinal and transverse reinforcement of 685 and 785 MPa, respectively. The VecTor2 finite element software was used to simulate the shear critical behavior of these columns. The combination axial compression load and monotonic loading were applied at this prediction. It is demonstrated that VecTor2 finite element software provides accurate prediction of load-deflection up to peak at applied load, but provide similar behavior at post peak load. The shear strength prediction provide by VecTor 2 are slightly conservative compare to test result.

  17. Slurry Bubble Column Reactor Optimization (book chapter)

    Energy Technology Data Exchange (ETDEWEB)

    Gamwo, I.K.; Gidaspow, D. (Illinois Inst. of Technology, Chicago, IL); Jung, J. (ANL)

    2007-03-01

    Slurry bubble column reactors (SBCR) are the preferred contactors for the conversion of syngas to fules and chemicals partially due to their superior heat and mass transfer characteristics. The multiphase fluid dynamics in these systems greatly affect the reactor volumetric productivity. Here, we have developed a computational fluid dynamics (CFD) assisted design methodology for searching the optimum particle size for maximum production in a SBCR. Reactor optimization due to heat exchanger configuration was also investigated. We have rearranged the heat exchangers in a SBCR and constructed a CFD model for a baffled reactor. The novel arrangement of the exchangers prevents the unfavorable high catalysts concentration at the lower stage of the reactor. Thus an optimum catalyst concentration is maintained during the course of the production of liquid fuels.

  18. Near shore floating oscillating wave column

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Three different types of floating buoys, using oscillating wave columns, have been considered for generating electric power in an Atlantic environment. The study considered the situation close to the shore, but in the ultimate it was hoped to deploy units offshore. Although other designs would have greater power capture efficiency, the Spar Buoy was studied in greatest depth as it was expected to have the edge in terms of building cost and operating economics. A risk assessment was carried out for both concrete and steel buoys. The report covers (1) history of the project development; (2) project definition; (3) power generation and sensitivities and (4) lessons learned. The study was sponsored by Great Britain's DTI.

  19. Maximum Variance Hashing via Column Generation

    Directory of Open Access Journals (Sweden)

    Lei Luo

    2013-01-01

    item search. Recently, a number of data-dependent methods have been developed, reflecting the great potential of learning for hashing. Inspired by the classic nonlinear dimensionality reduction algorithm—maximum variance unfolding, we propose a novel unsupervised hashing method, named maximum variance hashing, in this work. The idea is to maximize the total variance of the hash codes while preserving the local structure of the training data. To solve the derived optimization problem, we propose a column generation algorithm, which directly learns the binary-valued hash functions. We then extend it using anchor graphs to reduce the computational cost. Experiments on large-scale image datasets demonstrate that the proposed method outperforms state-of-the-art hashing methods in many cases.

  20. Education and training column: the learning collaborative.

    Science.gov (United States)

    MacDonald-Wilson, Kim L; Nemec, Patricia B

    2015-03-01

    This column describes the key components of a learning collaborative, with examples from the experience of 1 organization. A learning collaborative is a method for management, learning, and improvement of products or processes, and is a useful approach to implementation of a new service design or approach. This description draws from published material on learning collaboratives and the authors' experiences. The learning collaborative approach offers an effective method to improve service provider skills, provide support, and structure environments to result in lasting change for people using behavioral health services. This approach is consistent with psychiatric rehabilitation principles and practices, and serves to increase the overall capacity of the mental health system by structuring a process for discovering and sharing knowledge and expertise across provider agencies. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  1. GPR Diagnostics of columns in archaeological contexts

    Science.gov (United States)

    Soldovieri, Francesco; Masini, Nicola; Persico, Raffaele; Catapano, Ilaria

    2017-04-01

    In the last decade the use of Ground Penetrating radar (GPR) applied to cultural heritage has been strongly increasing thanks to both technological development of sensors and softwares for data processing and cultural reasons such as the increasing awareness of conservators and archaeologist of the benefits of this method in terms of reduction of costs and time and risk associated with restoration works. This made GPR a mature technique for investigating different types of works of art and building elements of historical interest, including masonry structures, frescoes, mosaics [1-3], in the context of scientific projects, decision support activities aimed at the diagnosis of decay pathologies, and educational activities. One of the most complex building elements to be investigated by GPR are the columns both for the geometry of the object and for the several expected features to be detected including fractures, dishomogeneities and metallic connection elements. The work deals with the Ground Penetrating Radar diagnostic surveys at the prestigious archaeological site of Pompei. In particular, GPR surveys were carried out in two different areas, Palestra Grande and Tempio di Giove. The first campaign was carried out also as educational activity of the "International School "GEOPHYSICS AND REMOTE SENSING FOR ARCHAEOLOGY". The School aimed at giving the opportunity to scholars, PhD students, researchers and specialists in Geophysics, Remote Sensing and Archaeology to deepen their knowledge and expertise with geophysical and remote sensing techniques for archaeology and cultural heritage documentation and management. This survey was carried on two kinds of columns, with circular and rectangular section in order to detect possible hidden defects affecting their integrity. The second survey was carried out at Tempio di Giove, on request of the Soprintendenza Pompei, in order to gain information about the presence of reinforcement structures, which may be put inside the

  2. Novel electrostatic column for ion projection lithography

    Energy Technology Data Exchange (ETDEWEB)

    Chalupka, A.; Stengl, G.; Buschbeck, H.; Lammer, G.; Vonach, H.; Fischer, R.; Hammel, E.; Loeschner, H.; Nowak, R.; Wolf, P. (IMS - Ion Microfabrication Systems GmbH, A-1020 Vienna (Austria)); Finkelstein, W.; Hill, R.W. (Advanced Lithography Group, Columbia, Maryland 21045 (United States)); Berry, I.L. (Department of Defense, Microelectronics Research Laboratory, Columbia, Maryland 21045 (United States)); Harriott, L.R. (AT T Bell Laboratories, Murray Hill, New Jersey 07974 (United States)); Melngailis, J. (University of Maryland, College Park, Maryland 20742 (United States)); Randall, J.N. (Texas Instruments, Dallas, Texas 75243 (United States)); Wolfe, J.C. (University of Houston, Houston, Texas 77204 (United States)); Stroh, H.; Wollnik, H. (University of Giessen, D-35392 Giessen (Germany)); Mondelli, A.A.; Petillo, J.J. (Science Applications International Corporation, McLean, Virginia 22102 (United States)); Leung, K. (Lawrence Berkeley Laboratory, University of Californi

    1994-11-01

    Ion projection lithography (IPL) is being considered for high volume sub-0.25-[mu]m lithography. A novel ion-optical column has been designed for exposing 20[times]20 mm[sup 2] fields at 3[times] reduction from stencil mask to wafer substrates. A diverging lens is realized by using the stencil mask as the first electrode of the ion-optical column. The second and third electrode form an accelerating field lens. The aberrations of the first two lenses (diverging lens and field lens) are compensated by an asymmetric Einzel lens projecting an ion image of the stencil mask openings onto the wafer substrate with better than 2 mrad telecentricity. Less than 30 nm intrafield distortion was calculated within 20[times]20 mm[sup 2] exposure fields. The calculation uncertainty is estimated to be about 10 nm. The calculation holds for helium ions with [approx]10 keV ion energy at the stencil mask and 150 keV ion energy at the wafer plane. A virtual ion source size of 10 [mu]m has been assumed. The calculated chromatic aberrations are less than 60 nm, assuming 6 eV energy spread of the ions extracted from a duoplasmatron source. Recently a multicusp ion source has been developed for which preliminary results indicate an energy spread of less than 2 eV. Thus, with a multicusp source chromatic aberrations of less than 20 nm are to be expected. The ion energy at the crossover between the field lens and the asymmetric Einzel lens is 200 keV. Therefore, stochastic space charge induced degradations in resolution can be kept sufficiently low. The divergence of the ion image projected to the wafer plane is less than 2 mrad. Thus, the usable'' depth of focus for the novel ion optics is in the order of 10 [mu]m.

  3. INFLUENCE OF MATERIAL MODELS ON PREDICTING THE FIRE BEHAVIOR OF STEEL COLUMNS.

    Science.gov (United States)

    Choe, Lisa; Zhang, Chao; Luecke, William E; Gross, John L; Varma, Amit H

    2017-01-01

    Finite-element (FE) analysis was used to compare the high-temperature responses of steel columns with two different stress-strain models: the Eurocode 3 model and the model proposed by National Institute of Standards and Technology (NIST). The comparisons were made in three different phases. The first phase compared the critical buckling temperatures predicted using forty seven column data from five different laboratories. The slenderness ratios varied from 34 to 137, and the applied axial load was 20-60 % of the room-temperature capacity. The results showed that the NIST model predicted the buckling temperature as or more accurately than the Eurocode 3 model for four of the five data sets. In the second phase, thirty unique FE models were developed to analyze the W8×35 and W14×53 column specimens with the slenderness ratio about 70. The column specimens were tested under steady-heating conditions with a target temperature in the range of 300-600 °C. The models were developed by combining the material model, temperature distributions in the specimens, and numerical scheme for non-linear analyses. Overall, the models with the NIST material properties and the measured temperature variations showed the results comparable to the test data. The deviations in the results from two different numerical approaches (modified Newton Raphson vs. arc-length) were negligible. The Eurocode 3 model made conservative predictions on the behavior of the column specimens since its retained elastic moduli are smaller than those of the NIST model at elevated temperatures. In the third phase, the column curves calibrated using the NIST model was compared with those prescribed in the ANSI/AISC-360 Appendix 4. The calibrated curve significantly deviated from the current design equation with increasing temperature, especially for the slenderness ratio from 50 to 100.

  4. Effect of axial mixing on RDC and PSE columns performance

    CERN Document Server

    Bastani, D

    2001-01-01

    Using the experimental data obtained from two RDC columns at two different sizes (7.62 and 21.9 cm) and one PSE column with 21.5 cm size, the effect of axial mixing on the performance of these columns was studied. Comparison between the experimental and theoretical (neglecting the axial mixing) number of transfer units indicates that, this effect in PSE columns is more than RDC columns (400% and 200% respectively). These results show that this effect can increase the height of the PSE column up to 4 times for a specific efficiency. Also the results show that this effect is more in law interfacial tension systems, which shows no need of application of agitation facilities when these systems are used.

  5. Observation of Vertical Column Density of NO_2 and SO_2 by A New Mobile Two optical paths Differential Optical Absorption Spectroscopy Technique

    Science.gov (United States)

    Hu, Zhaokun; Li*, Ang; Xie, Pinhua; Wu, Fengcheng; Xu, Jin

    2017-04-01

    The mobile differential optical absorption spectroscopy(DOAS) instrument collected the zenith scattered light in the UV or visible region and it was used to derive the vertical column density of trace gases above the measurement route. However, the slant column density is retrieved instead of vertical column density recently, which results in emission flux computing error. A new mobile multi light DOAS system was deployed, which set two angle telescopes(90°, 30°) to receive the scattered light respectively ,and set two shutters to switch the optical path quickly in the mobile platform. The slant column density in two different viewing directions were detected, and combined with the geometric approximation, the vertical column density of trace gas was obtained. The new system had high sensitivity and low uncertainty. A test experiment was performed in Huairou, Beijing using the new system. The distribution information of NO2 and SO2 vertical column density along the route was derived.

  6. Estimation of bearing capacity of floating group of stone columns

    OpenAIRE

    Fattah, Mohammed Y.; Mohammed A. Al-Neami; Shamel Al-Suhaily, Ahmed

    2017-01-01

    Stone column is one of the ground improvement techniques. This technique has a proven performance, short time schedule, durability, constructability and low costs. The stone column technique has been used as a method of reinforcement of soft ground over the past 30 years. The bearing capacity of the stone column still has high level of uncertainties because the existing formulas for the estimation of the bearing capacity are general and do not take into consideration the type of the stone col...

  7. Flow-through Column Experiments and Modeling of Microbially Mediated Cr(VI) Reduction at Hanford 100H

    Science.gov (United States)

    Yang, L.; Molins, S.; Beller, H. R.; Brodie, E. L.; Steefel, C.; Nico, P. S.; Han, R.

    2010-12-01

    transport simulations suggested that direct reduction of Cr(VI) by Fe(II) and Mn(II) released from the sediment could account for the observed Cr(VI) removal. The biogeochemical modeling was employed to test two hypotheses that could explain the release of Fe(II) and Mn(II) from the column sediments: 1) acetate produced by lactate fermentation provided the substrate for the growth of iron(III) and manganese(IV) oxide reducers, and 2) direct reduction of iron(III) and manganese(IV) oxides by hydrogen sulfide generated during sulfate reduction. Overall, experimental and modeling results suggested that Cr(VI) reduction in the sulfate-reducing columns occurred through a complex network of microbial reactions that included fermentation, sulfate reduction, and possibly the stimulated iron-reducing communities.

  8. Experimental investigations on steel-concrete composite columns for varying parameters

    Science.gov (United States)

    Aparna, V.; Vivek, D.; Neelima, Kancharla; Karthikeyan, B.

    2017-07-01

    In this study, the experimental investigations on steel tubes filled with different types of concrete are presented. Steel tubes filled with fibre reinforced concrete using lathe waste and steel tube with concerned confined with steel mesh were investigated. The combinations were compared with steel tubes with conventional concrete. A total of 4 concrete filled steel tube (CFST) combinations were made with tubes of diameter 100 mm with wall thickness 1.6 mm and a height of 300 mm. Axial compression test to examine the resisting capacity of the columns and push-out test for noting the bond strength were performed. Coupon tests were also conducted to determine the mechanical properties of steel. The structural behaviour of the composite columns was evaluated from on the test results. It was observed that steel tube filled fibre reinforced possessed better bond strength and resistance to axial load.

  9. Mini-columns for Conducting Breakthrough Experiments. Design and Construction

    Energy Technology Data Exchange (ETDEWEB)

    Dittrich, Timothy M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ware, Stuart Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-06-11

    Experiments with moderately and strongly sorbing radionuclides (i.e., U, Cs, Am) have shown that sorption between experimental solutions and traditional column materials must be accounted for to accurately determine stationary phase or porous media sorption properties (i.e., sorption site density, sorption site reaction rate coefficients, and partition coefficients or Kd values). This report details the materials and construction of mini-columns for use in breakthrough columns to allow for accurate measurement and modeling of sorption parameters. Material selection, construction techniques, wet packing of columns, tubing connections, and lessons learned are addressed.

  10. Investigations of infiltration processes from flooded areas by column experiments

    Science.gov (United States)

    Mohrlok, U.; Bethge, E.; Golalipour, A.

    2009-04-01

    In case of inundation of flood plains during flood events there is an increased risk of groundwater contamination due to infiltration of increasingly polluted river water. Specifically in densely populated regions, this groundwater may be used as source for drinking water supply. For the evaluation of this a detailed quantitative understanding of the infiltration processes under such conditions is required. In this context the infiltration related to a flood event can be described by three phases. The first phase is defined by the saturation of the unsaturated soils. Within the second phase infiltration takes place under almost saturated conditions determined by the hydraulic load of the flood water level. The drainage of the soils due to falling groundwater table is characterizing the third phase. Investigations by soil columns gave a detailed insight into the infiltration processes caused by flooding. Inflow at the soil top was established by a fixed water table fed by a Mariotte bottle. Free outflow and a groundwater table were used as lower boundary condition. Inflow and outflow volume were monitored. The evolution of the matrix pressure was observed by micro-tensiometers installed at several depths within the soil column. The flow processes during phase one and two were characterized by a tracer test. Some of the experiments were repeated in order to study the influence of preliminary events. Main results were a difference in infiltration due to the lower boundary condition with regard to inflow rate, outflow dynamics and matrix pressure evolution which is directly related to the water content evolution. Further, the influence of preliminary events was different for the different boundary conditions. A replacement of pre-event water could be observed which was confirmed by volume balances calculated for the infiltration experiments. Although these water balances were almost closed significant dynamics of the matrix pressure remained in soil column in the

  11. Comparison and Analysis of Steel Frame Based on High Strength Column and Normal Strength Column

    Science.gov (United States)

    Liu, Taiyu; An, Yuwei

    2018-01-01

    The anti-seismic performance of high strength steel has restricted its industrialization in civil buildings. In order to study the influence of high strength steel column on frame structure, three models are designed through MIDAS/GEN finite element software. By comparing the seismic performance and economic performance of the three models, the three different structures are comprehensively evaluated to provide some references for the development of high strength steel in steel structure.

  12. Experimental Ion Exchange Column With SuperLig 639 And Simulant Formulation

    Energy Technology Data Exchange (ETDEWEB)

    Morse, Megan; Nash, C.

    2013-08-26

    SuperLig®639 ion exchange resin was tested as a retrieval mechanism for pertechnetate, through decontamination of a perrhenate spiked 5M Simple Average Na{sup +} Mass Based Simulant. Testing included batch contacts and a three-column ion exchange campaign. A decontamination of perrhenate exceeding 99% from the liquid feed was demonstrated. Analysis of the first formulation of a SBS/WESP simulant found unexpectedly low concentrations of soluble aluminum. Follow-on work will complete the formulation.

  13. Influence of Brick Walls on the Temperature Distribution in Steel Columns in Fire

    Directory of Open Access Journals (Sweden)

    António J. P. Moura Correia

    2009-01-01

    Full Text Available This paper reports on a study of steel columns embedded in walls in fire. Several fire resistance tests were carried out at the Laboratory of Testing Materials and Structures of the University of Coimbra, in Portugal. The temperatures registered in several points of the experimental models are compared with those obtained in numerical simulations carried out with the SUPERTEMPCALC finite element program. 

  14. Numerical method for the estimation of column radial heterogeneity and of the actual column efficiency from tailing peak profiles.

    Science.gov (United States)

    Miyabe, Kanji; Guiochon, Georges

    2011-01-01

    It is probably impossible to prepare high-performance liquid chromatography (HPLC) columns that have a completely homogeneous packing structure. Many reports in the literature show that the radial distributions of the mobile phase flow velocity and the local column efficiency are not flat, even in columns considered as good. A degree of radial heterogeneity seems to be a common property of all HPLC columns and an important source of peak tailing, which prevents the derivation of accurate information on chromatographic behavior from a straightforward analysis of elution peak profiles. This work reports on a numerical method developed to derive from recorded peak profiles the column efficiency at the column center, the degree of column radial heterogeneity, and the polynomial function that best represents the radial distributions of the flow velocity and the column efficiency. This numerical method was applied to two concrete examples of tailing peak profiles previously described. It was demonstrated that this numerical method is effective to estimate important parameters characterizing the radial heterogeneity of chromatographic columns.

  15. Carbon dioxide degassing in fresh and saline water I: Degassing performance of a cascade column

    DEFF Research Database (Denmark)

    Moran, Damian

    2010-01-01

    A study was undertaken to measure carbon dioxide degassing in a cascade column operating with both fresh (0‰) and saline water (35‰ NaCl) at 15 °C. The cascade column contained bio-block type packing material, was 1.7 m long in each dimension, and was tested both with and without countercurrent a...... to differences in the ionization fractions of inorganic carbon species in the effluent water. The results indicate that CO2 removal will be more problematic for saline or seawater recirculating systems compared to freshwater systems.......A study was undertaken to measure carbon dioxide degassing in a cascade column operating with both fresh (0‰) and saline water (35‰ NaCl) at 15 °C. The cascade column contained bio-block type packing material, was 1.7 m long in each dimension, and was tested both with and without countercurrent air...... exchange. The CO2 concentration of the influent and effluent water was measured using submersible infrared CO2 probes over an influent range of 10-60 mg L−1 CO2. Carbon dioxide degassing was quantified in terms of the mass transfer coefficient (kLa, log concentration driving force divided by packing height...

  16. Reassessing the Plastic Hinge Model for Energy Dissipation of Axially Loaded Columns

    Directory of Open Access Journals (Sweden)

    R. M. Korol

    2014-01-01

    Full Text Available This paper investigates the energy dissipation potential of axially loaded columns and evaluates the use of a plastic hinge model for analysis of hi-rise building column collapse under extreme loading conditions. The experimental program considered seven axially loaded H-shaped extruded aluminum structural section columns having slenderness ratios that would be typical of floor-to-ceiling heights in buildings. All seven test specimens initially experienced minor-axis overall buckling followed by formation of a plastic hinge at the mid-height region, leading to local buckling of the flanges on the compression side of the plastic hinge, and eventual folding of the compression flanges. The experimental energy absorption, based on load-displacement relations, was compared to the energy estimates based on section plastic moment resistance based on measured yield stress and based on measured hinge rotations. It was found that the theoretical plastic hinge model underestimates a column’s actual ability to absorb energy by a factor in the range of 3 to 4 below that obtained from tests. It was also noted that the realizable hinge rotation is less than 180°. The above observations are based, of course, on actual columns being able to sustain high tensile strains at hinge locations without fracturing.

  17. Behavior of Reinforced Hybrid Concrete Corbel-Column Connection with Vertical Construction Joint

    Directory of Open Access Journals (Sweden)

    Ammar Yasir Ali

    2017-03-01

    Full Text Available In this paper, shear behavior of reinforced hybrid concrete connection of corbel-column is experimentally investigated. Nine homogenous and hybrid concrete corbel-column connections subjected to vertical applied loads were constructed and tested within two test groups (A, B. The experimental program included the effect of several variables such as type of hybrid concrete;high strength concrete (HSC or steel fiber reinforced concrete (SFRC, monolithic casting of hybrid concrete connection, and presence of construction joint at the interface of corbel-column. Experimental results showed significant effects of concrete hybridization on the structural behavior of connection specimens such as: ultimate strength, cracking loads, cracking patterns, and failure modes. Hybridization process in group (A included hybrid connection of corbel-column with HSC or SFRC corbel instated of NSC. This process led to increase the capacity of connection by (26%, 38% and shear cracking loads by (20%, 120% respectively. Moreover, connections of hybrid concrete corbels cast monolithically improved the shear capacity of corbels by (19%, 42% for HSC or SFRC respectively. In group (B, presence of construction joint at connection region reduced the shear capacity of connectionsby (10% to 22% and cracking loads by (23%-62% compared with connections cast monolithically.

  18. Effect of sintering columns on the heat transfer and flow characteristics of the liquid cooling vapor chambers

    Science.gov (United States)

    Naphon, Paisarn; Wiriyasart, Songkran

    2016-09-01

    The results of the heat and flow characteristics of working fluid inside the vapor chamber with different sintering columns of 20, 81, 225 are presented. The vapor chambers with one inlet port and four outlet ports are tested by using water as coolant. Parametric studies including different heat fluxes, number and size of wick columns, and flow rate of coolants on the cooling performance are considered. A three-dimensional heat and mass transfer model for vapor chamber with wick and without sintering plate and sintering columns are developed. The numerical simulation results show the velocity and pressure distribution of liquid and vapor phases of the working fluid inside the vapor chamber. It is found that the number of wick column have an important influence to the velocity and pressure phenomena of working fluid which results in thermal performance of vapor chamber. Reasonable agreement is obtained from the comparison between the measured data and the predicted results.

  19. Damage analysis of CFRP-confined circular concrete-filled steel tubular columns by acoustic emission techniques

    Science.gov (United States)

    Li, Dongsheng; Chen, Zhi; Feng, Quanming; Wang, Yanlei

    2015-08-01

    Damage properties of carbon fiber-reinforced polymer (CFRP) confined circular concrete-filled steel tubular (CCFT) columns were analyzed through acoustic emission (AE) signals. AE characteristic parameters were obtained through axial compression tests. The severity of damage to CFRP-CCFT columns was estimated using the growing trend of AE accumulated energy as basis. The bearing capacity of CFRP-CCFT columns and AE accumulated energy improved as CFRP layers increased. The damage process was studied using a number of crucial AE parameters. The cracks’ mode can be differentiated through the ratio of the rise time to the waveform amplitude and through average frequency analysis. With the use of intensity signal analysis, the damage process of the CFRP-CCFT columns can be classified into three levels that represent different degrees. Based on b-value analysis, the development of the obtained cracks can be defined. Thus, identifying an initial yielding and providing early warning is possible.

  20. Supervisory Model Predictive Control of the Heat Integrated Distillation Column

    DEFF Research Database (Denmark)

    Meyer, Kristian; Bisgaard, Thomas; Huusom, Jakob Kjøbsted

    2017-01-01

    This paper benchmarks a centralized control system based on model predictive control for the operation of the heat integrated distillation column (HIDiC) against a fully decentralized control system using the most complete column model currently available in the literature. The centralized control...

  1. Exploring the Sulfur Nutrient Cycle Using the Winogradsky Column

    Science.gov (United States)

    Rogan, Brian; Lemke, Michael; Levandowsky, Michael; Gorrell, Thomas

    2005-01-01

    The Winogradsky column demonstrates how the metabolic diversity of prokaryotes transforms sulfur to different forms with varying redox states and hence, supplies nutrients and/or energy to the organism. The Winogardsky column is an excellent way to show that not all bacteria are pathogens and they have an important role in the geochemical cycling…

  2. Uncertainty modelling of critical column buckling for reinforced ...

    Indian Academy of Sciences (India)

    gates the material uncertainties on column design and proposes an uncertainty model for critical column buckling reinforced concrete buildings. Fuzzy logic algorithm was employed in the study. Lower and upper bounds of elastic modulus representing mate- rial properties were defined to take uncertainties into account.

  3. Free vibration analysis of elastically supported Timoshenko columns ...

    Indian Academy of Sciences (India)

    Abstract. This paper deals with the free vibration of Timoshenko columns with attached masses having rotary inertia. The support of the model is elastically restrained against rotation. The concept of fixity factor is used to define the stiffness of the elastic connection relative to that of the column. The governing equation.

  4. Uncertain Buckling Load and Reliability of Columns with Uncertain Properties

    DEFF Research Database (Denmark)

    Köylüoglu, H. U.; Nielsen, Søren R. K.; Cakmak, A. S.

    Continuous and finite element methods are utilized to determine the buckling load of columns with material and geometrical uncertainties considering deterministic, stochastic and interval models for the bending rigidity of columns. When the bending rigidity field is assumed to be deterministic...

  5. An Automated Distillation Column for the Unit Operations Laboratory

    Science.gov (United States)

    Perkins, Douglas M.; Bruce, David A.; Gooding, Charles H.; Butler, Justin T.

    2005-01-01

    A batch distillation apparatus has been designed and built for use in the undergraduate unit operations laboratory course. The column is fully automated and is accompanied by data acquisition and control software. A mixture of 1­-propanol and 2-­propanol is separated in the column, using either a constant distillate rate or constant composition…

  6. Dynamic stability of a lightly damped column trapped by a ...

    African Journals Online (AJOL)

    In this paper we initiate an analytical approach for determining the dynamic buckling load of a finite viscously damped column acted upon by a harmonically slowly varying explicitly time dependent load. The viscous damping is considered light and the column rests on an elastic foundation that produces a nonlinear ...

  7. PROBABILISTIC FAILURE ANALYSIS OF A SOLID TIMBER COLUMN

    African Journals Online (AJOL)

    2012-11-03

    Nov 3, 2012 ... In this paper, a reliability evaluation of a solid timber column of square cross section subjected to axial and lateral loading in ... reliability evaluation, solid timber column, Eurocode, axial loading, slenderness ratio. 1. Introduction. The quality of an .... joint probability function. Fx(x) = P (nn i=1 {Xi ≤ xi}).

  8. Photochemical migration of liquid column in a glass tube

    Science.gov (United States)

    Muto, M.; Ayako, Y.; Yamamoto, K.; Yamamoto, M.; Kondo, Y.; Motosuke, M.

    2017-04-01

    A light-induced migration of liquid columns in a 2.5-mm glass capillary by photochemical isomerization was demonstrated. The isomerization of a surfactant AZTMA, which was added into ultrapure water, occurred by irradiating UV or visible light and results in the surface tension of the liquid. By utilizing this effect, the column manipulation was performed by irradiating the UV light to a half portion of the liquid column so that liquid-gas interface at two column ends had different surface tension dye to the photochemical isomerization. As a result, the migration of the columns generated by a difference in the Laplace pressure at two ends was observed. The columns firstly advanced at constant speeds depending on their lengths and then decelerated by mixing of isomers in the columns. Moreover, it was found that shorter the column length, higher the mobility. This characteristic was explained by the viscous friction, which counteracted the driving force, and the Marangoni convection in the vicinity of the interface.

  9. Thermal post-buckling of slender composite and FGM columns ...

    Indian Academy of Sciences (India)

    A simple and novel finite element (FE) formulation is proposed to study the thermal post-buckling of composite and FGM columns with axially immovable ends and operating in severe thermal environment. A linear eigenvalue analysis gives the critical buckling temperature but practically the buckled columns canwithstand ...

  10. Extended Langmuir model fitting to the filter column adsorption data ...

    African Journals Online (AJOL)

    Leachate samples collected at different depths of WQD column were analyzed for concentrations of zinc and copper ions using atomic absorption spectrometer. The removal efficiency was around 94% and 92% for zinc and copper respectively using column depth of 1 M at a flow rate of 12 ml/min. The adsorption model ...

  11. BUCKLING OF A COLUMN WITH TEMPERATURE DEPENDENT MATERIAL PROPERTIES

    Directory of Open Access Journals (Sweden)

    Ömer SOYKASAP

    2001-01-01

    Full Text Available Buckling of a column with temperature dependent material properties is investigated. Euler-Bernoulli theory of thin beams is used to derive the element matrices by means of the minimum potential energy principle. Temperature dependency of material properties is taken into account in the formulation. The column is divided into finite elements with the axial degrees of freedom defined at the outer fiber of the column. Column elements have simpler derivations and compact element matrices than those of classical beam-bending element. Some illustrative examples are presented to show the convergence of numerical results obtained by the use of new elements. The results are compared with those of the classical beam-bending element and analytical solution. The new element converges to the analytical results as powerful as the classical beam-bending element. The temperature effects on the buckling loads of the column with temperature dependent material properties are also examined.

  12. Tropospheric nitrogen dioxide column retrieval based on ground-based zenith-sky DOAS observations

    Science.gov (United States)

    Tack, Frederik; Hendrick, Francois; Goutail, Florence; Fayt, Caroline; Merlaud, Alexis; Pinardi, Gaia; Pommereau, Jean-Pierre; Van Roozendael, Michel

    2014-05-01

    Nitrogen dioxide (NO2) is one of the most important chemically active trace gases in the troposphere. Listed as primary pollutant, it is also a key precursor in the formation of tropospheric ozone, aerosols, and acid rain, and can contribute locally to radiative forcing. The long-term monitoring of this species is therefore of great relevance. Here we present a new method to retrieve tropospheric NO2 vertical column amounts from ground-based zenith-sky measurements of scattered sunlight. It is based on a four-step approach consisting of (1) the DOAS analysis of zenith radiance spectra using a fixed reference spectrum corresponding to low tropospheric NO2 content, (2) the determination of the residual amount in the reference spectrum using a Langley-plot-type method, (3) the removal of the stratospheric content from the daytime total slant column using stratospheric vertical columns measured at twilight and simulated stratospheric NO2 diurnal variation, (4) estimation of the tropospheric vertical columns by dividing the resulting tropospheric slant columns by appropriate air mass factors. The retrieval algorithm is tested on a 2 month dataset acquired from June to July 2009 by the BIRA MAX-DOAS instrument in the framework of the Cabauw (51.97° N, 4.93° E) Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI). The tropospheric vertical column amounts derived from zenith-sky observations are compared to the vertical columns retrieved from the off-axis and direct-sun measurements of the same MAX-DOAS instrument as well as to data of a co-located SAOZ (Système d'Analyse par Observations Zénithales) spectrometer operated by LATMOS. First results show a good agreement between the different data sets with correlation coefficients and slopes close to or larger than 0.85. We observe that the main error sources arise from the uncertainties in the determination of the residual NO2 amount in the reference spectrum, the stratospheric NO2 abundance and

  13. Mitigation of Liquefaction in Sandy Soils Using Stone Columns

    Science.gov (United States)

    Selcuk, Levent; Kayabalı, Kamil

    2010-05-01

    Soil liquefaction is one of the leading causes of earthquake-induced damage to structures. Soil improvement methods provide effective solutions to reduce the risk of soil liquefaction. Thus, soil ground treatments are applied using various techniques. However, except for a few ground treatment methods, they generally require a high cost and a lot of time. Especially in order to prevent the risk of soil liquefaction, stone columns conctructed by vibro-systems (vibro-compaction, vibro-replacement) are one of the traditional geotechnical methods. The construction of stone columns not only enhances the ability of clean sand to drain excess pore water during an earthquake, but also increases the relative density of the soil. Thus, this application prevents the development of the excess pore water pressure in sand during earthquakes and keeps the pore pressure ratio below a certain value. This paper presents the stone column methods used against soil liquefaction in detail. At this stage, (a) the performances of the stone columns were investigated in different spacing and diameters of columns during past earthquakes, (b) recent studies about design and field applications of stone columns were presented, and (c) a new design method considering the relative density of soil and the capacity of drenage of columns were explained in sandy soil. Furthermore, with this new method, earthquake performances of the stone columns constructed at different areas were investigated before the 1989 Loma Prieta and the 1994 Northbridge earthquakes, as case histories of field applications, and design charts were compiled for suitable spacing and diameters of stone columns with consideration to the different sandy soil parameters and earhquake conditions. Key Words: Soil improvement, stone column, excess pore water pressure

  14. Novel techniques for slurry bubble column hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Dudukovic, M.P.

    1999-05-14

    The objective of this cooperative research effort between Washington University, Ohio State University and Exxon Research Engineering Company was to improve the knowledge base for scale-up and operation of slurry bubble column reactors for syngas conversion and other coal conversion processes by increased reliance on experimentally verified hydrodynamic models. During the first year (July 1, 1995--June 30, 1996) of this three year program novel experimental tools (computer aided radioactive particle tracking (CARPT), particle image velocimetry (PIV), heat probe, optical fiber probe and gamma ray tomography) were developed and tuned for measurement of pertinent hydrodynamic quantities, such as velocity field, holdup distribution, heat transfer and bubble size. The accomplishments were delineated in the First Technical Annual Report. The second year (July, 1996--June 30, 1997) was spent on further development and tuning of the novel experimental tools (e.g., development of Monte Carlo calibration for CARPT, optical probe development), building up the hydrodynamic data base using these tools and comparison of the two techniques (PIV and CARPT) for determination of liquid velocities. A phenomenological model for gas and liquid backmixing was also developed. All accomplishments were summarized in the Second Annual Technical Report. During the third and final year of the program (July 1, 1997--June 30, 1998) and during the nine months no cost extension, the high pressure facility was completed and a set of data was taken at high pressure conditions. Both PIV, CT and CARPT were used. More fundamental hydrodynamic modeling was also undertaken and model predictions were compared to data. The accomplishments for this period are summarized in this report.

  15. A bridge column with superelastic NiTi SMA and replaceable rubber hinge for earthquake damage mitigation

    Science.gov (United States)

    Varela, Sebastian; ‘Saiid' Saiidi, M.

    2016-07-01

    This paper reports a unique concept for resilient bridge columns that can undergo intense earthquake loading and remain functional with minimal damage and residual drift. In this concept, the column is designed so that its components can be easily disassembled and reassembled to facilitate material recycling and component reuse. This is meant to foster sustainability of bridge systems while minimizing monetary losses from earthquakes. Self-centering and energy dissipation in the column were provided by unbonded superelastic nickel-titanium (NiTi) shape memory alloy bars placed inside a plastic hinge element made of rubber. This replaceable plastic hinge was in turn attached to a concrete-filled carbon fiber-reinforced polymer tube and a precast concrete footing that were designed to behave elastically. The proposed concept was evaluated experimentally by testing a ¼-scale column model under simulated near-fault earthquake motions on a shake table. After testing, the model was disassembled, reassembled and tested again. The seismic performance of the reassembled model was found to be comparable to that of the ‘virgin’ model. A relatively simple computational model of the column tested that was developed in OpenSees was able to match some of the key experimental response parameters.

  16. Biomechanical investigation of two plating systems for medial column fusion in foot.

    Science.gov (United States)

    Simons, Paul; Sommerer, Theresia; Zderic, Ivan; Wahl, Dieter; Lenz, Mark; Skulev, Hristo; Knobe, Matthias; Gueorguiev, Boyko; Richards, R Geoff; Klos, Kajetan

    2017-01-01

    Arthrodesis of the medial column (navicular, cuneiform I and metatarsal I) is performed for reasons such as Charcot arthropathy, arthritis, posttraumatic reconstruction or severe pes planus. However, the complication rate is still high and mainly resulting from inadequate fixation. Special plates, designed for medial column arthrodesis, seem to offer potential to reduce the complication rate. The aim of this study was to investigate biomechanically plantar and dorsomedial fusion of the medial column using two new plating systems. Eight matched pairs of human cadaveric lower legs were randomized in two groups and medial column fusion was performed using either plantar or dorsomedial variable-angle locking compression plates. The specimens were biomechanically tested under cyclic progressively increasing axial loading with physiological profile of each cycle. In addition to the machine data, mediolateral x-rays were taken every 250 cycles and motion tracking was performed to determine movements at the arthrodesis site. Statistical analysis of the parameters of interest was performed at a level of significance p = 0.05. Displacement of the talo-navicular joint after 1000, 2000 and 4000 cycles was significantly lower for plantar plating (p≤0.039) while there was significantly less movement in the naviculo-cuneiform I joint for dorsal plating post these cycle numbers (pcurrent setup under dynamic loading, there was no significant difference between the two plating systems with regard to stiffness and cycles to failure. Both tested techniques for dorsomedial and plantar plating appear to be applicable for arthrodesis of the medial column of the foot and other considerations, such as access morbidity, associated deformities or surgeon's preference, may also guide the choice of plating pattern. Further clinical studies are necessary before definitive recommendations can be given.

  17. Comparison Study of Axial Behavior of RPC-CFRP Short Columns

    Directory of Open Access Journals (Sweden)

    Taghreed Khaleefa Mohammed Ali

    2015-05-01

    Full Text Available In this paper, the axial behaviors of reactive powder     concrete (RPC short  columns confined with carbon fiber reinforced polymer (CFRP were   investigated. All the specimens have square cross section of 100 mm × 100   mm and length of 400 mm with aspect ratio 4. The experimental work consists   of three groups. The first group consists of six specimens of RPC with 2%  micro steel fiber, without ordinary reinforcing steel and confining by zero, one and two layer of CFRP respectively. The second group consists of six    specimens of RPC with 2% micro steel fiber and minimum ordinary reinforcing  steel and confining by zero, one and two layers of CFRP respectively. The third  group consists of four specimens of RPC without micro steel fiber and ordinary  reinforcing steel and confining by one and two layers of CFRP respectively.  Experimental data for strength, longitudinal and lateral displacement and  failure mode were obtained for each test. The toughness (area under the curve  for each test was obtained by using numerical integration. The RPC columns confined with CFRP showed stiffer behavior compared with RPC columns without CFRP. The ultimate load of the RPC columns with 2% micro steel  fiber + two layers of CFRP + minimum ordinary reinforcement were more than that of the RPC columns with 2% micro steel fiber + minimum ordinary   reinforcement and without CFRP by about 1.333.

  18. Seismic Behavior of Substandard RC Columns Retrofitted with Embedded Aramid Fiber Reinforced Polymer (AFRP Reinforcement

    Directory of Open Access Journals (Sweden)

    Engin C. Seyhan

    2015-12-01

    Full Text Available Many existing reinforced concrete structures were constructed with substandard characteristics. Low quality concrete, poor transverse reinforcement details and insufficient flexural strength are among the most common deficiencies. While substandard structures are in need of retrofitting, particularly in seismic areas, problems such as high costs and disturbance to occupants are major obstacles for retrofit interventions. Fiber reinforced polymers can provide feasible retrofit solutions with minimum disturbance to occupants. In this study, the basic aim is to investigate the flexural seismic performance of substandard reinforced concrete columns retrofitted with embedded longitudinal fiber reinforced polymer reinforcement without increasing the original dimensions of the columns. In the experimental study, the reference and retrofitted columns were tested under constant vertical and reversed cyclic lateral loads. Three different connection methods of aramid fiber reinforced polymer reinforcement to the footing were investigated experimentally. A significant enhancement was obtained in lateral flexural strength through the proposed retrofitting method. Furthermore, it was observed that the cyclic lateral drift capacities of the retrofitted columns were as high as 3%, which can be deemed as quite satisfactory against seismic actions. The comparison of the experimental data with analytical calculations revealed that a conventional design approach assuming composite action between concrete and fiber reinforced polymer reinforcement can be used for flexural retrofit design. Experimental results also demonstrated that strain limit for longitudinal fiber reinforced polymer (FRP reinforcement should be remarkably lower in case of reversed cyclic loading conditions.

  19. Extracting Concrete Thermal Characteristics from Temperature Time History of RC Column Exposed to Standard Fire

    Directory of Open Access Journals (Sweden)

    Jung J. Kim

    2014-01-01

    Full Text Available A numerical method to identify thermal conductivity from time history of one-dimensional temperature variations in thermal unsteady-state is proposed. The numerical method considers the change of specific heat and thermal conductivity with respect to temperature. Fire test of reinforced concrete (RC columns was conducted using a standard fire to obtain time history of temperature variations in the column section. A thermal equilibrium model in unsteady-state condition was developed. The thermal conductivity of concrete was then determined by optimizing the numerical solution of the model to meet the observed time history of temperature variations. The determined thermal conductivity with respect to temperature was then verified against standard thermal conductivity measurements of concrete bricks. It is concluded that the proposed method can be used to conservatively estimate thermal conductivity of concrete for design purpose. Finally, the thermal radiation properties of concrete for the RC column were estimated from the thermal equilibrium at the surface of the column. The radiant heat transfer ratio of concrete representing absorptivity to emissivity ratio of concrete during fire was evaluated and is suggested as a concrete criterion that can be used in fire safety assessment.

  20. Automatic Detection and Segmentation of Columns in As-Built Buildings from Point Clouds

    Directory of Open Access Journals (Sweden)

    Lucía Díaz-Vilariño

    2015-11-01

    Full Text Available Over the past few years, there has been an increasing need for tools that automate the processing of as-built 3D laser scanner data. Given that a fast and active dimensional analysis of constructive components is essential for construction monitoring, this paper is particularly focused on the detection and segmentation of columns in building interiors from incomplete point clouds acquired with a Terrestrial Laser Scanner. The methodology addresses two types of columns: round cross-section and rectangular cross-section. Considering columns as vertical elements, the global strategy for segmentation involves the rasterization of a point cloud onto the XY plane and the implementation of a model-driven approach based on the Hough Transform. The methodology is tested in two real case studies, and experiments are carried out under different levels of data completeness. The results show the robustness of the methodology to the presence of clutter and partial occlusion, typical in building indoors, even though false positives can be obtained if other elements with the same shape and size as columns are present in the raster.

  1. Tumor necrosis factor alpha: activity dependent expression and promotion of cortical column sleep in rats.

    Science.gov (United States)

    Churchill, L; Rector, D M; Yasuda, K; Fix, C; Rojas, M J; Yasuda, T; Krueger, J M

    2008-09-22

    Cortical surface evoked potentials (SEPs) are larger during sleep and characterize a sleep-like state in cortical columns. Since tumor necrosis factor alpha (TNF) may be involved in sleep regulation and is produced as a consequence of waking activity, we tested the hypothesis that direct application of TNF to the cortex will induce a sleep-like state within cortical columns and enhance SEP amplitudes. We found that microinjection of TNF onto the surface of the rat somatosensory cortex enhanced whisker stimulation-induced SEP amplitude relative to a control heat-inactivated TNF microinjection. We also determined if whisker stimulation enhanced endogenous TNF expression. TNF immunoreactivity (IR) was visualized after 2 h of deflection of a single whisker on each side. The number of TNF-IR cells increased in layers II-IV of the activated somatosensory barrel column. In two separate studies, unilateral deflection of multiple whiskers for 2 h increased the number of TNF-IR cells in layers II-V in columns that also exhibited enhanced cellular ongogene (Fos-IR). TNF-IR also colocalized with NeuN-IR suggesting that TNF expression was in neurons. Collectively these data are consistent with the hypotheses that TNF is produced in response to neural activity and in turn enhances the probability of a local sleep-like state as determined by increases in SEP amplitudes.

  2. Behavior and Performance of GFRP Reinforced Concrete Columns with Various Types of Stirrups

    Directory of Open Access Journals (Sweden)

    Woraphot Prachasaree

    2015-01-01

    Full Text Available Fiber reinforced polymer (FRP composites are gaining acceptance in concrete structural applications due to their high ratio of strength/stiffness to self-weight and corrosion resistance. This study focused on the structural behavior and the performance of concrete columns internally reinforced with glass fiber reinforced plastic (GFRP rebars. Twelve series of concrete columns with varied longitudinal reinforcement, cross section, concrete cover, and type of lateral reinforcement were tested under compression loading. The results show that the amount of GFRP longitudinal and lateral reinforcement slightly affects the column strength. The lateral reinforcement affects the confining pressure and inelastic deformation, and its contribution to the confined compressive strength increases with the GFRP reinforcement ratio. In addition, the confining pressure increases both concrete strength and deformability in the inelastic range. The confinement effectiveness coefficient varied from 3.0 to 7.0 with longitudinal reinforcement. The average deformability factors were 4.2 and 2.8 with spirals and ties, respectively. Lateral reinforcement had a more pronounced effect on deformability than on column strength.

  3. Transport and degradation of metalaxyl and isoproturon in biopurification columns inoculated with pesticide-primed material.

    Science.gov (United States)

    De Wilde, Tineke; Spanoghe, Pieter; Sniegowksi, Kristel; Ryckeboer, Jaak; Jaeken, Peter; Springael, Dirk

    2010-01-01

    Laboratory column displacement experiments were performed to examine whether addition of pesticide-primed material to the matrix of an on-farm biopurification system (BPS), intended to remove pesticides from agricultural waste water, positively affects the degradation of mobile pesticides in the system. Percolated column microcosms with varying types and amounts of metalaxyl and/or isoproturon-primed material or non-primed material were irrigated with water artificially contaminated with isoproturon and/or metalaxyl. Transport of isoproturon was well described using the convection dispersion equation and no dissipation was observed, even in columns inoculated with isoproturon-primed material. On the other hand, delayed dissipation of metalaxyl, i.e., after an initial lag phase, was encountered in all columns receiving metalaxyl. In all systems, dissipation could be described using the Monod model indicating that a metalaxyl degrading population grew in the systems. There was a clear correlation between the lag phase and the amount of metalaxyl-primed material added to the system, i.e., increasing amounts of added material resulted into shorter lag phases and hence more rapid initiation of growth-associated metalaxyl degradation in the system. Our observations suggest that indeed pesticide-primed material can reduce the start-up phase of degradation of mobile pesticides in a BPS and as such can increase its efficiency. However, the primed material should be chosen carefully and preferentially beforehand tested for its capacity to degrade the pesticide.

  4. Mechanical loading regulates organization of the actin cytoskeleton and column formation in postnatal growth plate.

    Science.gov (United States)

    Killion, Christy H; Mitchell, Elizabeth H; Duke, Corey G; Serra, Rosa

    2017-07-07

    Longitudinal growth of bones occurs at the growth plates where chondrocytes align into columns that allow directional growth. Little is known about the mechanisms controlling the ability of chondrocytes to form columns. We hypothesize that mechanical load and the resulting force on chondrocytes are necessary during active growth for proper growth plate development and limb length. To test this hypothesis, we created a mouse model in which a portion of the sciatic nerve from one hind limb was transected at postnatal day 8 to cause paralysis to that limb. At 6 and 12 wk postsurgery, the hind limb had significantly less bone mineral density than contralateral controls, confirming reduced load. At 8 and 14 wk postsurgery, tibiae were significantly shorter than controls. The paralyzed growth plate showed disruptions to column organization, with fewer and shorter columns. Polarized light microscopy indicated alterations in collagen fiber organization in the growth plate. Furthermore, organization of the actin cytoskeleton in growth plate chondrocytes was disrupted. We conclude that mechanical load and force on chondrocytes within the growth plate regulate postnatal development of the long bones. © 2017 Killion, Mitchell, et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  5. Zwitterionic silica-based monolithic capillary columns for isocratic and gradient hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Moravcová, Dana; Planeta, Josef; Kahle, Vladislav; Roth, Michal

    2012-12-28

    This study introduces zwitterionic monolithic capillary columns intended for isocratic and gradient HILIC separations. Silica-based monolithic capillary columns (100 μm × 150 mm) prepared by acidic hydrolysis of tetramethoxysilane in the presence of polyethylene glycol and urea were modified by a sulfoalkylbetaine zwitterion ([2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl)-ammonium hydroxide) to HILIC stationary phase. The prepared columns were evaluated under the isocratic and gradient separation conditions using a standard mixture containing nucleic acid bases, nucleosides, and 2-deoxynucleosides. Mobile phases contained high concentration of acetonitrile (95-85%, v/v) and 5-50mM ammonium acetate or ammonium formate in the pH range of 3-6. The synthesized columns showed a long-term stability under the separation conditions while the high permeability and efficiency originating from dual structure of the silica monolith were preserved. The relative standard deviations (RSDs) for the retention times of tested solutes were lower than 2% under the isocratic conditions and lower than 3.5% under the gradient conditions. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Development Of ABEC Column For Separation Of Tc-99 From Northstar Dissolved Target Solution

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, Dominique C. [Argonne National Lab. (ANL), Argonne, IL (United States); Bennett, Megan E. [Argonne National Lab. (ANL), Argonne, IL (United States); Naik, Seema R. [Argonne National Lab. (ANL), Argonne, IL (United States); ling, lei [Argonne National Lab. (ANL), Argonne, IL (United States); Wang, N-H. Linda [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    Batch and column breakthrough experiments were performed to determine isotherms and mass-transfer parameters for adsorption of Tc on aqueous biphasic extraction chromatographic (ABEC) sorbent in two solutions: 200 g/L Mo, 5.1 M K+, 1 M OH-, and 0.1 M NO3- (Solution A) and 200 g/L Mo, 9.3 M K+, 5 M OH-, and 0.1 M NO3- (Solution B). Good agreement was found between the isotherm values obtained by batch and column breakthrough studies for both Solutions A and B. Potassium-pertechnetate intra-particle diffusivity on ABEC resin was estimated by VERSE simulations, and good agreement was found among a series of column-breakthrough experiments at varying flow velocities, column sizes, and technetium concentrations. However, testing of 10 cc cartridges provided by NorthStar with Solutions A and B did not give satisfactory results, as significant Tc breakthrough was observed and ABEC cartridge performance varied widely among experiments. These different experimental results are believed to be due to inconsistent preparation of the ABEC resin prior to packing and/or inconsistent packing.

  7. Consolidation Theory for a Stone Column Composite Foundation under Multistage Loading

    Directory of Open Access Journals (Sweden)

    Shenggen Huang

    2016-01-01

    Full Text Available The consolidation theories considering instant load cannot fully reveal the consolidation mechanism of a stone column composite foundation used in the expressway embankments due to the time effect of loading; that is, the expressway embankments are often constructed in several stages for a long time. Meanwhile, owing to the special property that the pile-soil stress ratio is larger than 1, the consolidation theory for sand drain well foundation cannot be used directly in the consolidation analysis of stone column composite foundation. Based on the principle that the vertical load applied on the composite foundation is shared by the stone column and the surrounding soil, the governing solutions for the stone column composite foundation under a multistage load are established. By virtue of the separation of variables, the corresponding solutions of degree of consolidation for loading stage and maintaining load stage are derived separately. According to the Carrillo theorem, the solution for the average total degree of consolidation of entire composite foundation is also obtained. Finally, the reasonableness of the present solution has been verified by comparing the consolidation curve calculated by the present solution with that measured by site test.

  8. Reliability assessment of slender concrete columns at the stability failure

    Science.gov (United States)

    Valašík, Adrián; Benko, Vladimír; Strauss, Alfred; Täubling, Benjamin

    2018-01-01

    The European Standard for designing concrete columns within the use of non-linear methods shows deficiencies in terms of global reliability, in case that the concrete columns fail by the loss of stability. The buckling failure is a brittle failure which occurs without warning and the probability of its formation depends on the columns slenderness. Experiments with slender concrete columns were carried out in cooperation with STRABAG Bratislava LTD in Central Laboratory of Faculty of Civil Engineering SUT in Bratislava. The following article aims to compare the global reliability of slender concrete columns with slenderness of 90 and higher. The columns were designed according to methods offered by EN 1992-1-1 [1]. The mentioned experiments were used as basis for deterministic nonlinear modelling of the columns and subsequent the probabilistic evaluation of structural response variability. Final results may be utilized as thresholds for loading of produced structural elements and they aim to present probabilistic design as less conservative compared to classic partial safety factor based design and alternative ECOV method.

  9. Leaching and transformability of transgenic DNA in unsaturated soil columns.

    Science.gov (United States)

    Poté, John; Teresa Ceccherini, Maria; Rosselli, Walter; Wildi, Walter; Simonet, Pascal; Vogel, Timothy M

    2010-01-01

    Unsaturated soil columns were used to examine the transport of the plasmid pLEPO1 and plant DNA (transplastomic tobacco DNA), both carrying an antibiotic resistance gene (aadA gene), and the capacity of bacteria to incorporate the gene in their genome after its passage through the soil. Soil columns containing a top leaf layer had sterile water percolated through them at a rate of 0.5mLh(-1). DNA from column leachate water was extracted and analyzed. Quantitative measurements included total DNA concentrations in the water and the transformation frequencies of Acinetobacter sp. BD413 by DNA in the column effluent. Qualitative measurements included the relative degradation of DNA after passage in the columns by agarose gel electrophoresis and the potential of effluent DNA to transform bacteria, leading to the production of antibiotic-resistant bacteria. The presence of aadA gene in the leachate water of soil columns suggests the mobility of DNA in unsaturated soil medium. The extent of DNA degradation was found to be proportional to its residence time in the soil column while a fraction of DNA was always able to incorporate into the Acinetobacter genome under all conditions studied. These results suggest that biologically active transgenic DNA might be transported downward by rain in unsaturated soils.

  10. Finite Element Analysis for CFST Columns under Blast Loading

    Directory of Open Access Journals (Sweden)

    Peyman Beiranvand

    2017-10-01

    Full Text Available The columns of frame structures are the key load-bearing components and the exterior columns are susceptible to attack in terrorist blasts. When subjected to blast loads, the columns would suffer a loss of bearing capacity to a certain extent due to the damage imparted which may lead to their collapse and even cause the progressive collapse of the whole structure . The concrete-filled steel columns have been extensively used in the world due to the existence of all suitable characteristics of concrete and steel, more ductility, increasing concrete confinement using the steel wall, the large energy-absorption capacity and the appropriate fire behavior. In the present study, the concrete-filled steel square columns have been simulated under the influence of the blast load using the ABAQUS software. These responses have been compared for scaled distances based on the distance to the source and the weight of the explosive material. As a result, it can be seen that although concrete deformation has been restricted using the steel tube, the inner layer of concrete has been seriously damaged and the column displacement has been decreased by increasing the scaled distance. We also concluded that the concrete-filled steel columns have the high ductility and the blast resistance.

  11. Comparison of antibody titers using conventional tube technique versus column agglutination technique in ABO blood group incompatible renal transplant.

    Science.gov (United States)

    Bhangale, Amit; Pathak, Amardeep; Pawar, Smita; Jeloka, Tarun

    2017-01-01

    Measurement of alloantibody titer to a red cell antigen (ABO titers) is an integral part of management of ABO incompatible kidney transplants (ABOiKT). There are different methods of titer estimation. Alloantibody detection by tube titration and Gel agglutination columns are accepted methodologies. It is essential to find the difference in titers between the two methods so as to set the 'cut-off' titer accordingly, depending upon the method used. We did a prospective observational study to compare and correlate the ABO titers using these two different techniques - conventional tube technique (CTT) and the newer column agglutination technique (CAT). A total of 67 samples were processed in parallel for anti-A/B antibodies by both tube dilution and column agglutination methods. The mean titer by conventional tube method was 38.5 + 96.6 and by the column agglutination test was 96.4 + 225. The samples correlated well with Spearman rho correlation coefficient of 0.94 (P = 0.01). The column agglutination method for anti A/B titer estimation in an ABO incompatible kidney transplant is more sensitive, with the column agglutination results being approximately two and half fold higher (one more dilution) than that of tube method.

  12. Comparison of antibody titers using conventional tube technique versus column agglutination technique in ABO blood group incompatible renal transplant

    Directory of Open Access Journals (Sweden)

    Amit Bhangale

    2017-01-01

    Full Text Available Introduction: Measurement of alloantibody titer to a red cell antigen (ABO titers is an integral part of management of ABO incompatible kidney transplants (ABOiKT. Material and Methods: There are different methods of titer estimation. Alloantibody detection by tube titration and Gel agglutination columns are accepted methodologies. It is essential to find the difference in titers between the two methods so as to set the 'cut-off' titer accordingly, depending upon the method used. Results: We did a prospective observational study to compare and correlate the ABO titers using these two different techniques – conventional tube technique (CTT and the newer column agglutination technique (CAT. A total of 67 samples were processed in parallel for anti-A/B antibodies by both tube dilution and column agglutination methods. The mean titer by conventional tube method was 38.5 + 96.6 and by the column agglutination test was 96.4 + 225. The samples correlated well with Spearman rho correlation coefficient of 0.94 (P = 0.01. Conclusion: The column agglutination method for anti A/B titer estimation in an ABO incompatible kidney transplant is more sensitive, with the column agglutination results being approximately two and half fold higher (one more dilution than that of tube method.

  13. A new oxalate co-conversion technology based on liquid/liquid extraction columns

    Energy Technology Data Exchange (ETDEWEB)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Allegri, Patrick [CEA Nuclear Energy Division - Fuel Cycle Technology Division - System and Chemical Engineering Device Marcoule - 30207 Bagnols sur Ceze (France)

    2008-07-01

    The current objective of fabricating non proliferating nuclear fuel by 'direct' coprecipitation of uranium, plutonium and minor actinides requires a new process to replace the (co)precipitation step. The technological impact of an increased capacity on the work zone could require the development of a different concept for a continuous device capable of ensuring the proposed goal. A new type of device designed and patented by the Cea was tested in 2007. The patent is for organic confinement in a pulsed column. First, precipitation of cerium or neodymium alone has been carried out in this device, with satisfactory results. Moreover, a recent test campaign demonstrated that a uranium-cerium co-precipitate easily forms when the two nitrates are mixed in a pulsed column of the same size operating under very similar process conditions. Qualitatively, the co-precipitate meets the process requirements. (authors)

  14. Modeling of a pulsed fluid column and coupled piping with structural finite elements

    Science.gov (United States)

    Saxon, J. B.; Jones, J. U.; Anderson, F. E.

    1989-01-01

    Structural finite elements have been used to model the coupled fluidic-structural response of a liquid oxygen (LOX) feedline at a rocket engine test facility. The model simulates the effects of Pogo pulsing, a test procedure which uses a piston in a side branch to impart an oscillatory pressure pulse to the LOX column as it feeds the engine. In addition to the feedline's structural characteristics, the model accounts for the mass and axial stiffness of the fluid column, the oscillatory pulse of the piston, and the hydraulic impedance of the rocket engine. The model was used to determine the relations between piston stroke, pressure oscillation at the engine inlet, and structural excitation of the feedline. This paper develops the concepts employed by the model.

  15. Experimental and Theoretical Analysis of Hollow Steel Columns Strengthening by CFRP

    Directory of Open Access Journals (Sweden)

    Keykha A.H.

    2015-09-01

    Full Text Available The need for strengthening and retrofitting is well known and extensive research is progressing in this field. The reasons for strengthening and retrofitting are numerous: increased loads, changes in use, deterioration, and so on. In recent years, the use of carbon fiber reinforced polymer (CFRP for strengthening has shown to be a competitive method, both regarding structural performance, and economical aspects. Extensive research has been carried out in this field. However, most of the research has been undertaken on concrete structures and for confinement, flexural, and shear strengthening. Limited research has been carried out on steel structures strengthened with CFRP. This paper presents axially loaded steel columns strengthened for increased load. The topic is studied theoretically and through laboratory tests. The theory covers analytical methods. Carbon fiber reinforced polymers has been used to strengthen the columns. The tests have been undertaken on full scale specimens, non-strengthened for reference, partially strengthened and fully strengthened

  16. Control structure selection for energy integrated distillation column

    DEFF Research Database (Denmark)

    Hansen, J.E.; Jørgensen, Sten Bay

    1998-01-01

    This paper treats a case study on control structure selection for an almost binary distillation column. The column is energy integrated with a heat pump in order to transfer heat from the condenser to the reboiler. This integrated plant configuration renders the possible control structures somewhat...... different from what is usual for binary distillation columns. Further the heat pump enables disturbances to propagate faster through the system. The plant has six possible actuators of which three must be used to stabilize the system. Hereby three actuators are left for product purity control. An MILP...

  17. Evaluation of Controller Tuning Methods Applied to Distillation Column Control

    DEFF Research Database (Denmark)

    Nielsen, Kim; W. Andersen, Henrik; Kümmel, Professor Mogens

    A frequency domain approach is used to compare the nominal performance and robustness of dual composition distillation column control tuned according to Ziegler-Nichols (ZN) and Biggest Log Modulus Tuning (BLT) for three binary distillation columns, WOBE, LUVI and TOFA. The scope...... of this is to examine whether ZN and BLT design yield satisfactory control of distillation columns. Further, PI controllers are tuned according to a proposed multivariable frequency domain method. A major conclusion is that the ZN tuned controllers yield undesired overshoot and oscillation and poor stability robustness...

  18. Buckling Instability of Self-Assembled Colloidal Columns

    Science.gov (United States)

    Swan, James W.; Vasquez, Paula A.; Furst, Eric M.

    2014-09-01

    Suspended, slender self-assembled domains of magnetically responsive colloids are observed to buckle in microgravity. Upon cessation of the magnetic field that drives their assembly, these columns expand axially and buckle laterally. This phenomenon resembles the buckling of long beams due to thermal expansion; however, linear stability analysis predicts that the colloidal columns are inherently susceptible to buckling because they are freely suspended in a Newtonian fluid. The dominant buckling wavelength increases linearly with column thickness and is quantitatively described using an elastohydrodynamic model and the suspension thermodynamic equation of state.

  19. A Modelling Framework for Conventional and Heat Integrated Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    Diabatic operation of distillation columns can lead to signicant reductions in energy utilization and operation cost compared to conventional (adiabatic) distillation columns, at an expense of an increased complexity of design and operation. The earliest diabatic distillation conguration dates back...... constitutes a problem in relations to achieving industrial acceptance. There is clearly a need for research and comparative studies which can help to provide analysis of the pros and cons of novel and intensied distillation processes compared to conventional columns for a range of separations. These studies...

  20. A comparative study between release analysis and column flotation

    Energy Technology Data Exchange (ETDEWEB)

    Jorge Pineres; Juan Barraza [Universidad del Valle, Cali (Colombia)

    2007-07-01

    This paper shows the results of a comparative study between release analysis and column flotation of three Colombian coals: Guachinte (South West), Cerrejon (North) and Nech (Midlands). Analysis release was used in order to evaluate the coal potential cleaning in terms of both low ash and high organic recovery of froth. Results from release analysis were compared with those from a column flotation and showed that the froth from Nechi coal had the highest recovery and the lowest ash, followed by Cerrejon and then by Guachinte. Results of release analysis were in agreement with the column flotation. 10 refs., 4 figs., 1 tab.

  1. Experimental Investigation on Seismic Behavior of Steel Truss-RC Column Hybrid Structure with Steel Diagonal Braces

    Directory of Open Access Journals (Sweden)

    Bo Wang

    2018-01-01

    Full Text Available This paper aims to provide an experimental support on seismic performance evaluation of the steel braced truss-RC (reinforced concrete column hybrid structure, which could be applied as the air-cooled supporting structural system in large-capacity thermal power plants located in strong earthquake prone regions. A series of pseudo-dynamic tests (PDTs and quasi-static tests (QSTs were performed on a 1/8-scaled sub-structure. The dynamic characteristics, lateral deformation patterns, deterioration behavior, hysteretic behavior and failure mechanisms were investigated. Test results showed that the first vibration mode is torsion, which is caused by the small torsional stiffness of this kind of hybrid structure. The lateral deformation shape is shear mode, and the drift ratio of the structure above the corbel is significantly less than that of the column below the corbel. Earthquake energy is mainly dissipated by the RC pipe columns where cracks mainly occurred at the bottom of column and lower part of corbel. The failure mechanisms were identified indicating that the steel braces improved the global stiffness and modified the load transfer mechanism. This study affirms that the steel braced truss-RC column hybrid structure has the sufficient ductility and good energy dissipation capacity to satisfy the design requirements in high seismic regions.

  2. Confinement of Reinforced-Concrete Columns with Non-Code Compliant Confining Reinforcement plus Supplemental Pen-Binder

    Directory of Open Access Journals (Sweden)

    Anang Kristianto

    2012-11-01

    Full Text Available One of the important requirements for earthquake resistant building related to confinement is the use of seismic hooks in the hoop or confining reinforcement of reinforced-concrete column elements. However, installation of a confining reinforcement with a 135-degree hook is not easy. Therefore, in practice, many construction workers apply a confining reinforcement with a 90-degreehook (non-code compliant. Based on research and records of recent earthquakes in Indonesia, the use of a non-code compliant confining reinforcement for concrete columns produces structures with poor seismic performance. This paper presents a study that introduces an additional element that is expected to improve the effectiveness of concrete columns confined with a non-code compliant confining reinforcement. The additional element, named a pen-binder, is used to keep the non-code compliant confining reinforcement in place. The effectiveness of this element under pure axial concentric loading was investigatedcomprehensively.The specimens tested in this study were 18 concrete columns,with a cross-section of 170 mm x 170 mm and a height of 480 mm. The main test variables were the material type of the pen-binder, the angle of the hook, and the confining reinforcement configuration.The test results indicate that adding pen-binders can effectively improve the strength and ductility of the column specimens confined with a non-code compliant confining reinforcement

  3. Effect of bacterial extracellular polymers on the saturated hydraulic conductivity of sand columns.

    OpenAIRE

    Vandevivere, P; Baveye, P.

    1992-01-01

    Columns were packed with clean quartz sand, sterilized, and inoculated with different strains of bacteria, which multiplied within the sand at the expense of a continuous supply of fresh nutrient medium. The saturated hydraulic conductivity (HCsat) of the sand was monitored over time. Among the four bacterial strains tested, one formed a capsule, one produced slime layers, and two did not produce any detectable exopolymers. The last two strains were nonmucoid variants of the first two. Only o...

  4. Engineering evaluation of 55-year-old timber columns recycled from an industrial military building

    Science.gov (United States)

    Robert H. Falk; David Green; Douglas Rammer; Scott F. Lantz

    2000-01-01

    A large sample of timber was collected from a 548,000-ft.2 (50,900-m2) World War II era industrial military building containing approximately 1, 875,000 board feet (4,400 m3) of lumber and timber. Sixty 12-foot- (3.6-m-) long, nominal 8- by 8-inches (190-by 190-mm) Douglas-fir columns were tested at the USDA Forest Service, Forest Products Laboratory, and the results...

  5. Effects of Predamaged Level on Confined HSC Columns

    Directory of Open Access Journals (Sweden)

    Ma Chau-Khun

    2017-01-01

    Full Text Available In the design of repair works for damaged concrete, an accurate and representative stress-strain model is of important. The stress-strain model for damaged high strength concrete (HSC repaired with post-tensioning steel straps confinement yet available, although the confining method has been proven to be effective in improving the performance of non-damaged HSC. A series of experimental test was carried out to investigate the stress-strain relationships of such concrete. A total of 24 HSC cylinders were compressed until certain damaged levels, then repaired by using steel straps. Two important parameters have been identified to have significant effects on the stress-strain relationship of such repaired concrete, namely the confining volumetric ratio and damaged levels. These parameters were incorporated into the development of stressstrain model, which later was shown to correlate well with the experimental results. This paper also has evidenced that existing stressstrain models of damaged concrete are not suitable to be directly applied to the design of repair works using post-tensioning steel straps confinement that produce external lateral stress on damaged columns before subsequent loading applied.

  6. Electronic Nose using Gas Chromatography Column and Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Hari Agus Sujono

    2011-08-01

    Full Text Available The conventional electronic nose usually consists of an array of dissimilar chemical sensors such as quartz crystal microbalance (QCM combined with pattern recognition algorithm such as Neural network. Because of parallel processing, the system needs a huge number of sensors and circuits which may emerge complexity and inter-channel crosstalk problems. In this research, a new type of odor identification which combines between gas chromatography (GC and electronic nose methods has been developed. The system consists of a GC column and a 10-MHz quartz crystal microbalance sensor producing a unique pattern for an odor in time domain. This method offers advantages of substantially reduced size, interferences and power consumption in comparison to existing odor identification system. Several odors of organic compounds were introduced to evaluate the selectivity of the system. Principle component analysis method was used to visualize the classification of each odor in two-dimensional space. This system could resolve common organic solvents, including molecules of different classes (aromatic from alcohols as well as those within a particular class (methanol from ethanol and also fuels (premium from pertamax. The neural network can be taught to recognize the odors tested in the experiment with identification rate of 85 %. It is therefore the system may take the place of human nose, especially for poisonous odor evaluations.

  7. REALIGNED MODEL PREDICTIVE CONTROL OF A PROPYLENE DISTILLATION COLUMN

    Directory of Open Access Journals (Sweden)

    A. I. Hinojosa

    Full Text Available Abstract In the process industry, advanced controllers usually aim at an economic objective, which usually requires closed-loop stability and constraints satisfaction. In this paper, the application of a MPC in the optimization structure of an industrial Propylene/Propane (PP splitter is tested with a controller based on a state space model, which is suitable for heavily disturbed environments. The simulation platform is based on the integration of the commercial dynamic simulator Dynsim® and the rigorous steady-state optimizer ROMeo® with the real-time facilities of Matlab. The predictive controller is the Infinite Horizon Model Predictive Control (IHMPC, based on a state-space model that that does not require the use of a state observer because the non-minimum state is built with the past inputs and outputs. The controller considers the existence of zone control of the outputs and optimizing targets for the inputs. We verify that the controller is efficient to control the propylene distillation system in a disturbed scenario when compared with a conventional controller based on a state observer. The simulation results show a good performance in terms of stability of the controller and rejection of large disturbances in the composition of the feed of the propylene distillation column.

  8. Avoiding monocular artifacts in clinical stereotests presented on column-interleaved digital stereoscopic displays.

    Science.gov (United States)

    Serrano-Pedraza, Ignacio; Vancleef, Kathleen; Read, Jenny C A

    2016-11-01

    New forms of stereoscopic 3-D technology offer vision scientists new opportunities for research, but also come with distinct problems. Here we consider autostereo displays where the two eyes' images are spatially interleaved in alternating columns of pixels and no glasses or special optics are required. Column-interleaved displays produce an excellent stereoscopic effect, but subtle changes in the angle of view can increase cross talk or even interchange the left and right eyes' images. This creates several challenges to the presentation of cyclopean stereograms (containing structure which is only detectable by binocular vision). We discuss the potential artifacts, including one that is unique to column-interleaved displays, whereby scene elements such as dots in a random-dot stereogram appear wider or narrower depending on the sign of their disparity. We derive an algorithm for creating stimuli which are free from this artifact. We show that this and other artifacts can be avoided by (a) using a task which is robust to disparity-sign inversion-for example, a disparity-detection rather than discrimination task-(b) using our proposed algorithm to ensure that parallax is applied symmetrically on the column-interleaved display, and (c) using a dynamic stimulus to avoid monocular artifacts from motion parallax. In order to test our recommendations, we performed two experiments using a stereoacuity task implemented with a parallax-barrier tablet. Our results confirm that these recommendations eliminate the artifacts. We believe that these recommendations will be useful to vision scientists interested in running stereo psychophysics experiments using parallax-barrier and other column-interleaved digital displays.

  9. In-situ polymerization PLOT columns I: divinylbenzene

    Science.gov (United States)

    Shen, T. C.

    1992-01-01

    A novel method for preparation of porous-layer open-tubular (PLOT) columns is described. The method involves a simple and reproducible, straight-forward in-situ polymerization of monomer directly on the metal tube.

  10. EX1001 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1001: Ship Shakedown between 20100126...

  11. EX1105 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1105: Field Trials of EM302 Multibeam...

  12. EX1607 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1607: CAPSTONE Wake Island PRI MNM...

  13. Science Column: Reconstruction: The Experimental Side of Digital Forensics

    Directory of Open Access Journals (Sweden)

    Fred Cohen

    2013-12-01

    Full Text Available Many in digital forensics seem to forget that the science part of digital forensics means experimentation and that implies a whole lot of things that most practitioners never learned.(see PDF for full column

  14. EX0802 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0802: Operation Halloween Shakedown...

  15. Relationship between chlorophyll-a and column primary production

    Digital Repository Service at National Institute of Oceanography (India)

    Dalal, S.G.; Bhargava, R.M.S.

    Relationship between surface chlorophyll a and column primary production has been established to help in estimating the latter more quickly and accurately. The equation derived is Primary Production, y = 0.54 Ln Chl a - 0.6. The relationship...

  16. EX1102 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1102: ROV and Camera Sled Integration...

  17. EX1604 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1604: CAPSTONE Wake Island PRIMNM...

  18. EX1303 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1303: New England Seamount Chain...

  19. EX0908 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0908: Transit to Hawaii between 20090728...

  20. EX1104 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1104: Mid-Cayman Rise Exploration...

  1. EX1505 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1505: October 2015 Transit: Honolulu, HI...

  2. EX1603 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1603: Hohonu Moana: Exploring the Deep...

  3. EX1006 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1006: Hawaii to San Francisco Transit to...

  4. Associations between the Cervical Vertebral Column and Craniofacial Morphology

    DEFF Research Database (Denmark)

    Sonnesen, Ane Liselotte

    2010-01-01

    Aim. To summarize recent studies on morphological deviations of the cervical vertebral column and associations with craniofacial morphology and head posture in nonsyndromic patients and in patients with obstructive sleep apnoea (OSA). Design. In these recent studies, visual assessment of the cerv......Aim. To summarize recent studies on morphological deviations of the cervical vertebral column and associations with craniofacial morphology and head posture in nonsyndromic patients and in patients with obstructive sleep apnoea (OSA). Design. In these recent studies, visual assessment...... of the cervical vertebral column and cephalometric analysis of the craniofacial skeleton were performed on profile radiographs of subjects with neutral occlusion, patients with severe skeletal malocclusions and patients with OSA. Material from human triploid foetuses and mouse embryos was analysed histologically....... Results. Recent studies have documented associations between fusion of the cervical vertebral column and craniofacial morphology, including head posture in patients with severe skeletal malocclusions. Histological studies on prenatal material supported these findings. Conclusion. It is suggested...

  5. CONSOLIDATION RELIABILITY ANALYSIS OF STONE COLUMN REINFORCED GROUND

    Directory of Open Access Journals (Sweden)

    K. S. NG

    2017-10-01

    Full Text Available Stone column is an effective ground improvement method to improve the weak ground. This paper describes the implementation of reliability based analysis on the consolidation behaviour of stone column reinforced ground. Hasofer-Lind reliability index is computed involving non-correlated normal random variables which include stone column diameter, coefficient of volume compressibility, coefficient of consolidation and stress concentration ratio. The sensitivity of these variables on the effect of consolidation settlement is investigated in this study. Results show the importance of considering spatial variability in design and analysis of stone column reinforced ground. The probabilities of failure inferred from reliability indices are compared with Monte Carlo simulation where good agreements are obtained.

  6. ENGINEERING DEVELOPMENT OF SLURRY BUBBLE COLUMN REACTOR (SBCR) TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Bernard A. Toseland, Ph.D.

    1999-03-01

    The major technical objectives of this program are threefold: (1) to develop the design tools and a fundamental understanding of the fluid dynamics of a slurry bubble column reactor to maximize reactor productivity, (2) to develop the mathematical reactor design models and gain an understanding of the hydrodynamic fundamentals under industrially relevant process conditions, and (3) to develop an understanding of the hydrodynamics and their interaction with the chemistries occurring in the bubble column reactor. Successful completion of these objectives will permit more efficient usage of the reactor column and tighter design criteria, increase overall reactor efficiency, and ensure a design that leads to stable reactor behavior when scaling up to large diameter reactors. The past three months of research have been focused on two major areas of bubble column hydrodynamics: (1) pressure and temperature effects on gas holdup and (2) region transition using a sparger as a gas distributor.

  7. EX1602 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1602: Mission System Shakedown/CAPSTONE...

  8. EX1305 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1305: Summer Ecosystem Monitoring Survey...

  9. BCB polymer based row-column addressed CMUT

    DEFF Research Database (Denmark)

    Havreland, Andreas Spandet; Ommen, Martin Lind; Silvestre, Chantal

    2017-01-01

    This paper presents an inexpensive, low temperature and rapid fabrication method for capacitive micromachined ultrasonic transducers (CMUT). The fabrication utilizes the bonding and dielectric properties of the photosensitive polymer Benzocyclobutene (BCB). A BCB based row-column addressed CMUT...

  10. EX0901 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0901: Mapping Shakedown Cruise between...

  11. Fast determination of anions on a short coated column.

    Science.gov (United States)

    Li, Jing; Zhu, Yan; Guo, Yingying

    2006-06-16

    In this paper, a simple method for the separation and determination of common inorganic anions by fast ion-exchange chromatography, using a modified short (25 mm x 4.6 mm) monolithic column, is reported. Coating the column with a cationic surfactant, cetylpyridinium chloride (CPC), the isocratic separation of some inorganic anions in minutes was possible, by direct or indirect UV detection. The coated column demonstrated excellent stability over time, even at a high flow-rate, giving retention times with an average relative standard deviation of 1.3% for over 10 consecutive runs. The developed column exhibited unusual selectivity for common anions, was successfully applied to the rapid analysis of inorganic anions of food samples, river water and factory waste water samples.

  12. EX1206 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1206: Northeast and Mid-Atlantic Canyons...

  13. EX0903 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0903: Mapping Field Trial I Mendocino...

  14. EX0902 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0902: ROV Harbor Trials between 20090425...

  15. EX0907 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0907: Mapping Field Trial IV Habitat...

  16. EX0905 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0905: Mapping Field Trials II Mendocino...

  17. Science Column: Reconstruction: The Experimental Side of Digital Forensics

    OpenAIRE

    Fred Cohen

    2013-01-01

    Many in digital forensics seem to forget that the science part of digital forensics means experimentation and that implies a whole lot of things that most practitioners never learned.(see PDF for full column)

  18. TOMS Column Ozone Earth Probe (MODIS Ancillary Data)

    Data.gov (United States)

    National Aeronautics and Space Administration — OZONEEP is a daily, gridded 2-D Column Ozone product from the TOMS instrument in ASCII format. It consists of averaged ozone data from 00Z hours to 24Z hours with...

  19. Seismic Performance of Self-Consolidating Concrete Bridge Columns

    Science.gov (United States)

    2017-09-01

    The high amount of confining lateral steel required by seismic design provisions for rectangular bridge columns can cause steel congestion. The high amount of confining steel may hinder the placement of conventional concrete (CC). Self-consolidating ...

  20. Modified method to improve the design of Petlyuk distillation columns

    National Research Council Canada - National Science Library

    Zapiain-Salinas, Javier G; Barajas-Fernández, Juan; González-García, Raúl

    2014-01-01

    A response surface analysis was performed to study the effect of the composition and feeding thermal conditions of ternary mixtures on the number of theoretical stages and the energy consumption of Petlyuk columns...

  1. Conceptual analysis of single-feed heterogeneous distillation columns

    National Research Council Canada - National Science Library

    Carlos Arturo Martinez Riascos; Libardo Estupiñan Perez

    2015-01-01

      Separation in heterogeneous distillation columns is attained by interaction of two liquid and one vapor phases, interaction of three phases involves complexities due to the determination of vapor...

  2. EX1106 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1106: Exploration Mapping to Davisville,...

  3. EX0801 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0801: Mapping Operations Shakedown...

  4. Varied overstrain injuries of the vertebral column conditioned by evolution

    Energy Technology Data Exchange (ETDEWEB)

    Kohlbach, W.

    1983-08-01

    During physiological growth of the juvenile vertebral column, various stages of stability occur which are characterized by the condition of the marginal rim of the vertebral bodies. If the vertebral juvenile column is overstrained, these variations in stability results in a variety of damage to vertebral bodies and vertebral disks. One of these lesions corresponds to Scheuermann's disease (osteochondrosis of vertebral epiphyses in juveniles). Damage of the vertebral column due to overstrain can occur only if the overstrain is applied in upright position. Since Man alone can damage his vertebral column in upright position (as a result of his evolutionary development), Scheuermann's thesis is confirmed that Scheuermann's disease is confined to Man. Spondylolysis/spondylolisthesis is also a damage caused by overstrain. Here, too, the damage can occur only if the load is exercised in upright position, with the exception of a slanted positioning of the intervertebral components.

  5. EX1705 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1705: American Samoa, Kingman/Palmyra,...

  6. EX1702 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1702: American Samoa Expedition:...

  7. EX1704 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1704: American Samoa and Cook Islands...

  8. EX1701 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX1701: Kingman/Palmyra, Jarvis (Mapping)...

  9. Rapid Column Extraction method for SoilRapid Column Extraction method for Soil

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod, L. III; Culligan, Brian K.

    2005-11-07

    The analysis of actinides in environmental soil and sediment samples is very important for environmental monitoring as well as for emergency preparedness. A new, rapid actinide separation method has been developed and implemented that provides total dissolution of large soil samples, high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and DGA-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu) neptunium (Np), uranium (U), americium (Am), and curium (Cm) using a single multi-stage column combined with alpha spectrometry. The method combines a rapid fusion step for total dissolution to dissolve refractory analytes and matrix removal using cerium fluoride precipitation to remove the difficult soil matrix. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized.

  10. Development of Dynamic Models for a Reactive Packed Distillation Column

    OpenAIRE

    Abdulwahab GIWA; Süleyman KARACAN

    2012-01-01

    This work has been carried out to develop dynamic models for a reactive packed distillation column using the production of ethyl acetate as the case study. The experimental setup for the production of ethyl acetate was a pilot scale packed column divided into condenser, rectification, acetic acid feed, reaction, ethanol feed, stripping and reboiler sections. The reaction section was filled with Amberlyst 15 catalyst while the rectification and the stripping sections were both filled raschig r...

  11. Convection in a Single Column -- Modelling, Algorithm and Analysis

    CERN Document Server

    Bokhove, Onno; Dedner, Andreas; Esler, Gavin; Norbury, John; Turner, Matthew R; Vanneste, Jacques; Cullen, Mike

    2016-01-01

    The group focused on a model problem of idealised moist air convection in a single column of atmosphere. Height, temperature and moisture variables were chosen to simplify the mathematical representation (along the lines of the Boussinesq approximation in a height variable defined in terms of pressure). This allowed exact simple solutions of the numerical and partial differential equation problems to be found. By examining these, we identify column behaviour, stability issues and explore the feasibility of a more general solution process.

  12. C-store: storing relational data by columns

    OpenAIRE

    Částek, Petr

    2009-01-01

    Non standard approach to the implementation of relational databases this work implements a database system storing the data by columns instead of rows. It is based on the C Store system design and is limited only to the fundamental solution issues. Two areas are being solved: the initial creation of the database, including import of static database data from another source, and querying. The database does not store the data in tables but in projections groups of columns of the same length. By...

  13. Epicritic Sensation in Cervical Spinal Cord Injury: Diagnostic Gains Beyond Testing Light Touch

    NARCIS (Netherlands)

    Velstra, Inge-Marie; Bolliger, Marc; Baumberger, Michael; Rietman, Johan Swanik; Curt, Armin

    2013-01-01

    Applied as a bedside test of gross dorsal column function, the testing of light touch (LT) sensation is of high clinical value in the diagnosis of human spinal cord injury (SCI). However, the assessment of overall dorsal column deficit by testing only LT may be limited, because the dorsal column

  14. Seismic performance of circular reinforced concrete bridge columns constructed with grade 80 reinforcement.

    Science.gov (United States)

    2014-08-01

    This project assessed the use of ASTM A706 Grade 80 reinforcing bars in reinforced concrete columns. : Grade 80 is not currently allowed in reinforced concrete columns due to lack of information on the : material characteristics and column performanc...

  15. Detecting CO2 and CH4 Urban Emissions using Column-Integrated Dry Air mole Fractions, In-Situ Tower Dry Air Mole Fractions, and WRF Modeling

    Science.gov (United States)

    Hillyard, P. W.; Lauvaux, T.; Podolske, J. R.; Iraci, L. T.; Miles, N. L.; Richardson, S.; Davis, K.; Roehl, C. M.; Wunch, D.; Wennberg, P. O.; Blavier, J. F.; Allen, N.; Barrow, E.; Deng, A.

    2015-12-01

    Total column measurements of atmospheric gases are important because of their ability to be performed via satellites that provide global coverage. Here we will present measurements of CO2 and CH4 dry air mole fractions obtained using a Fourier Transform Spectrometer (FTS) as part of the Total Carbon Column Observing Nework (TCCON). These measurements were performed in Indianapolis as part of the Indianapolis Flux Experiment (INFLUX). We will extract urban emission signals using high resolution modeling and in-situ tower measurements of CO2 and CH4 mixing ratios. In addition to quantifying the influence of surface emissions on the column measurements, we will also decompose the atmospheric columns into sub-layers to identify the origin of air masses at various altitudes. We will show that the variability in the origins of air masses increases the complexity of the observed signals in the column, which limits our ability to combine surface and column measurements. This work will also highlight the potential application of using total column measurements to detect local urban signals. We conclude that the deployment of multiple column sensors is required in order to measure the upwind (background) and downwind (urban) conditions. Such work provides a test case for using these methods with satellite measurements such as GOSAT and OCO-2 that provide global coverage.

  16. Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent.

    Science.gov (United States)

    Kozaki, Daisuke; Nakatani, Nobutake; Mori, Masanobu; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2012-07-01

    A unified ion-exclusion chromatography (IEC) system for monitoring anionic and cationic nutrients like NH4+, NO2-, NO3-, phosphate ion, silicate ion and HCO3- was developed and applied to several environmental waters. The IEC system consisted of four IEC methodologies, including the IEC with ultraviolet (UV) form connected with detection at 210 nm for determining NH4+ on anion-exchange separation column in OH anion-exchange UV-conversion column in I- form in tandem, the IEC with UV-detection at 210 nm for determining simultaneously NO3- and NO3- on cation-exchange separation column in H+ form, the IEC with UV-detection at 210 nm for determining HCO3- on cation-exchange separation column in H+ form connected with anion-exchange UV-conversion column in I- form in tandem, and the IEC with visible-detection based on molybdenum-blue reaction for determining simultaneously silicate and phosphate ions on cation-exchange separation column in H+ form. These IEC systems were combined through three manually-driven 6-port column selection valves to select each separation column to determine selectively the ionic nutrients. Using this sequential water quality monitoring system, the analytical performances such as calibration linearity, reproducibility, detection limit and recovery were also tested under the optimized chromatographic conditions. This novel water quality monitoring system has been applied successfully for the determination of the ionic eutrophication components in sub-urban river waters.

  17. On the buckling of an elastic holey column

    Science.gov (United States)

    Johnson, C. G.; Jain, U.; Hazel, A. L.; Pihler-Puzović, D.; Mullin, T.

    2017-11-01

    We report the results of a numerical and theoretical study of buckling in elastic columns containing a line of holes. Buckling is a common failure mode of elastic columns under compression, found over scales ranging from metres in buildings and aircraft to tens of nanometers in DNA. This failure usually occurs through lateral buckling, described for slender columns by Euler's theory. When the column is perforated with a regular line of holes, a new buckling mode arises, in which adjacent holes collapse in orthogonal directions. In this paper, we firstly elucidate how this alternate hole buckling mode coexists and interacts with classical Euler buckling modes, using finite-element numerical calculations with bifurcation tracking. We show how the preferred buckling mode is selected by the geometry, and discuss the roles of localized (hole-scale) and global (column-scale) buckling. Secondly, we develop a novel predictive model for the buckling of columns perforated with large holes. This model is derived without arbitrary fitting parameters, and quantitatively predicts the critical strain for buckling. We extend the model to sheets perforated with a regular array of circular holes and use it to provide quantitative predictions of their buckling.

  18. Design of zeolite ion-exchange columns for wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, S.M.; Arnold, W.D.; Byers, C.H.

    1991-01-01

    Oak Ridge National Laboratory plans to use chabazite zeolites for decontamination of wastewater containing parts-per-billion levels of {sup 90}Sr and {sup 137}Cs. Treatability studies indicate that such zeolites can remove trace amounts of {sup 90}Sr and {sup 137}Cs from wastewater containing high concentrations of calcium and magnesium. These studies who that zeolite system efficiency is dependent on column design and operating conditions. Previous results with bench-scale, pilot-scale, and near-full-scale columns indicate that optimized design of full-scale columns could reduce the volume of spent solids generation by one-half. The data indicate that shortcut scale-up methods cannot be used to design columns to minimize secondary waste generation. Since the secondary waste generation rate is a primary influence on process cost effectiveness, a predictive mathematical model for column design is being developed. Equilibrium models and mass-transfer mechanisms are being experimentally determined for isothermal multicomponent ion exchange (Ca, Mg, Na, Cs, and Sr). Mathematical models of these data to determine the breakthrough curves for different column configurations and operating conditions will be used to optimize the final design of full-scale treatment plant. 32 refs., 6 figs., 3 tabs.

  19. Using a box instead of a column for process chromatography.

    Science.gov (United States)

    Ghosh, Raja

    2016-10-14

    Columns with relatively short bed-height to diameter ratios are frequently used for process-scale chromatography applications such as biopharmaceutical purification. Non-uniform flow distribution within such columns could result in broad and poorly resolved eluted peaks, which could in turn affect purity, recovery and productivity of the process. Different strategies centered on improved column header design have been proposed for addressing this problem. This paper describes a radically different approach, i.e. the use of a chromatography box (or chromato-box) instead of a column, for addressing the challenges posed by flow mal-distribution in process-scale, packed-bed chromatography devices. The design of the chromatography box devices used in this study is based on a laterally-fed membrane chromatography (or LFMC) device, that has been described and discussed in several recent papers. The performances of two chromatography box devices were compared with their equivalent columns in terms of sharpness and asymmetry of flow-through and eluted peaks, number of theoretical plates per metre, and peak resolution in binary and ternary protein separations. In each of the above comparisons, the chromatography box devices performed better than their equivalent columns, clearly indicating their potential as an alternative in process-scale chromatography applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Mechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire.

    Science.gov (United States)

    Liu, Wenchao; Cao, Wanlin; Zhang, Jianwei; Wang, Ruwei; Ren, Lele

    2017-03-09

    Recycled aggregate concrete (RAC) is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST) columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens were subjected to axial compression tests at room temperature and the other six specimens were subjected to axial compression tests after a fire exposure. The main parameters of the specimens include the wall thickness of the steel tube (steel content) and the type of concrete materials. Several parameters as obtained from the experimental results were compared and analyzed, including the load-bearing capacity, deformation capacity, and failure characteristics of the specimens. Meanwhile, rate of loss of bearing capacity of specimens exposed to fire were calculated based on the standards EC4 and CECS28:90. The results show that concrete material has a large influence on the rate of loss of bearing capacity in the case of a relatively lower steel ratio. While steel content has little effect on the rate of loss of bearing capacity of concrete-filled steel tube (CFST) columns after fire, it has a relatively large influence on the loss rate of bearing capacity of the RACFST columns. The loss of bearing capacity of the specimens from the experiment is more serious than that from the calculation. As the calculated values are less conservative, particular attention should be given to the application of recycled aggregate concrete in actual structures.

  1. Mechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire

    Science.gov (United States)

    Liu, Wenchao; Cao, Wanlin; Zhang, Jianwei; Wang, Ruwei; Ren, Lele

    2017-01-01

    Recycled aggregate concrete (RAC) is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST) columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens were subjected to axial compression tests at room temperature and the other six specimens were subjected to axial compression tests after a fire exposure. The main parameters of the specimens include the wall thickness of the steel tube (steel content) and the type of concrete materials. Several parameters as obtained from the experimental results were compared and analyzed, including the load-bearing capacity, deformation capacity, and failure characteristics of the specimens. Meanwhile, rate of loss of bearing capacity of specimens exposed to fire were calculated based on the standards EC4 and CECS28:90. The results show that concrete material has a large influence on the rate of loss of bearing capacity in the case of a relatively lower steel ratio. While steel content has little effect on the rate of loss of bearing capacity of concrete-filled steel tube (CFST) columns after fire, it has a relatively large influence on the loss rate of bearing capacity of the RACFST columns. The loss of bearing capacity of the specimens from the experiment is more serious than that from the calculation. As the calculated values are less conservative, particular attention should be given to the application of recycled aggregate concrete in actual structures. PMID:28772634

  2. Mechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire

    Directory of Open Access Journals (Sweden)

    Wenchao Liu

    2017-03-01

    Full Text Available Recycled aggregate concrete (RAC is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens were subjected to axial compression tests at room temperature and the other six specimens were subjected to axial compression tests after a fire exposure. The main parameters of the specimens include the wall thickness of the steel tube (steel content and the type of concrete materials. Several parameters as obtained from the experimental results were compared and analyzed, including the load-bearing capacity, deformation capacity, and failure characteristics of the specimens. Meanwhile, rate of loss of bearing capacity of specimens exposed to fire were calculated based on the standards EC4 and CECS28:90. The results show that concrete material has a large influence on the rate of loss of bearing capacity in the case of a relatively lower steel ratio. While steel content has little effect on the rate of loss of bearing capacity of concrete-filled steel tube (CFST columns after fire, it has a relatively large influence on the loss rate of bearing capacity of the RACFST columns. The loss of bearing capacity of the specimens from the experiment is more serious than that from the calculation. As the calculated values are less conservative, particular attention should be given to the application of recycled aggregate concrete in actual structures.

  3. Revised Thermal Analysis of LANL Ion Exchange Column

    Energy Technology Data Exchange (ETDEWEB)

    Laurinat, J

    2006-04-11

    This document updates a previous calculation of the temperature distributions in a Los Alamos National Laboratory (LANL) ion exchange column.1 LANL operates two laboratory-scale anion exchange columns, in series, to extract Pu-238 from nitric acid solutions. The Defense Nuclear Facilities Safety Board has requested an updated analysis to calculate maximum temperatures for higher resin loading capacities obtained with a new formulation of the Reillex HPQ anion exchange resin. The increased resin loading capacity will not exceed 118 g plutonium per L of resin bed. Calculations were requested for normal operation of the resin bed at the minimum allowable solution feed rate of 30 mL/min and after an interruption of flow at the end of the feed stage, when one of the columns is fully loaded. The object of the analysis is to demonstrate that the decay heat from the Pu-238 will not cause resin bed temperatures to increase to a level where the resin significantly degrades. At low temperatures, resin bed temperatures increase primarily due to decay heat. At {approx}70 C a Low Temperature Exotherm (LTE) resulting from the reaction between 8-12 M HNO{sub 3} and the resin has been observed. The LTE has been attributed to an irreversible oxidation of pendant ethyl benzene groups at the termini of the resin polymer chains by nitric acid. The ethyl benzene groups are converted to benzoic acid moities. The resin can be treated to permanently remove the LTE by heating a resin suspension in 8M HNO{sub 3} for 30-45 minutes. No degradation of the resin performance is observed after the LTE removal treatment. In fact, heating the resin in boiling ({approx}115-120 C) 12 M HNO{sub 3} for 3 hr displays thermal stability analogous to resin that has been treated to remove the LTE. The analysis is based on a previous study of the SRS Frames Waste Recovery (FWR) column, performed in support of the Pu-238 production campaign for NASA's Cassini mission. In that study, temperature transients

  4. Kansas Department of Transportation column expert : ultimate shear capacity of circular columns using the simplified modified compression field theory.

    Science.gov (United States)

    2015-09-01

    The importance of the analysis of circular columns to accurately predict their ultimate confined : capacity under shear-flexure-axial force interaction domain is recognized in light of the extreme load event : imposed by the current American Associat...

  5. Buckling driven debonding in sandwich columns

    DEFF Research Database (Denmark)

    Østergaard, Rasmus Christian

    2008-01-01

    results from two mechanisms: (a) interaction of local debond buckling and global buckling and (b) the development of a damaged zone at the debond crack tip. Based on the pronounced imperfection sensitivity, the author predicts that an experimental measurement of the strength of sandwich structures may...... exhibit a large scatter caused by geometrical variations between test specimens. (C) 2007 Elsevier Ltd. All rights reserved....

  6. Batch and column studies of the stabilization of toxic heavy metals in dredged marine sediments by hematite after bioremediation.

    Science.gov (United States)

    Mamindy-Pajany, Yannick; Geret, Florence; Hurel, Charlotte; Marmier, Nicolas

    2013-08-01

    The management of dredged sediments is an important issue in coastal regions where the marine sediments are highly polluted by metals and organic pollutants. In this paper, mineral-based amendments (hematite, zero-valent iron and zeolite) were used to stabilize metallic pollutants (As, Cd, Cu, Mo, Ni, Pb, and Zn) in a contaminated marine sediment sample. Mineral-based amendments were tested at three application rates (5 %, 10 %, and 15 %) in batch experiments in order to select the best amendment to perform column experiments. Batch tests have shown that hematite was the most efficient amendment to stabilize inorganic pollutants (As, Cd, Cu, Mo, Ni, Pb, and Zn) in the studied sediment. Based on batch tests, hematite was used at one application rate equal to 5 % to conduct column experiments. Column tests confirmed that hematite was able to decrease metal concentrations in leachates from stabilized sediment. The stabilization rates were particularly high for Cd (67 %), Mo (80 %), and Pb (90 %). The Microtox solid phase test showed that hematite could decrease significantly the toxicity of stabilized sediment. Based on batch and column experiments, it emerged that hematite could be a suitable adsorbent to stabilize metals in dredged marine sediment.

  7. A Semi-Quantitative Study of the Impact of Bacterial Pollutant Uptake Capability on Bioremediation in a Saturated Sand-Packed Two-Dimensional Microcosm: Experiments and Simulation

    Science.gov (United States)

    Zheng, S.; Ford, R.; Van den Berg, B.

    2016-12-01

    The transport of microorganisms through the saturated porous matrix of soil is critical to the success of bioremediation in polluted groundwater systems. Chemotaxis can direct the movement of microorganisms toward higher concentration of pollutants, which they chemically transform and use as carbon and energy sources, resulting in enhanced bioremediation efficiency. In addition to accessibility and degradation kinetics, bacterial uptake of the pollutants is a critical step in bioremediation. In order to study the impact of bacterial pollutant uptake capability on bioremediation, a two-dimensional microcosm packed with saturated sand was set up to mimic the natural groundwater system where mass transfer limitation poses a barrier (see the figure below). Toluene source was continuously injected into the microcosm from an injection port. Pseudomonas putida F1, either wild-type (WT) or genetic mutants (TodX knockout, TodX and CymD knockout) that exhibited impaired toluene uptake capability, were co-injected with a conservative tracer into the microcosm either above or below the toluene. After each run, samples were collected from a dozen effluent ports to determine the concentration profiles of the bacteria and tracers. Toluene serves as the only carbon source throughout the microcosm. So the percent recovery, which is the ratio of cells collected at the outlet over that at the inlet, can be used as the indicator for bioremediation efficiency. Comparisons were made between the WT and mutant strains, where PpF1 WT showed greater proliferation than the mutants. Comparisons for low and high toluene source concentrations showed that the PpF1 mutant strains exhibited a greater degree of growth inhibition than WT at higher toluene concentration. A mathematical model was applied to evaluate the impact of various parameters on toluene uptake illustrating that with reasonable parameter estimates, the bioremediation efficiency was more sensitive to proliferation than transport. The results show that in a two-dimensional microcosm mimicking features of the natural groundwater system, the toluene uptake capability of bacteria can be the "remediation-rate-liming" step, implying the potential of engineering bacteria for bioremediation efficiency enhancement.

  8. nduced hyperlipidemic rats. Methods: Column chromatographic fractionation of butanol fraction of total methanol extract of leaves of Bauhinia variegata (Linn. yields four sub-fractions (sub-fraction A-D. All sub-fractions tested for their anti-hyperlipidemic activity. Sub-fractions administered at a dose of 65 mg/kg (oral to the Triton WR-1339 induced hyperlipidemic rats and total cholesterol, triglycerides, HDL, LDL and VLDL

    Directory of Open Access Journals (Sweden)

    Deepak Kumar

    2012-10-01

    Full Text Available Objective: To investigate the effect and evaluation of Anti-hyperlipidemic activity guided subfraction isolated from total methanolic extract of Bauhinia variegata (Linn. leaves on Triton WR-1339 induced hyperlipidemic rats. Methods: Column chromatographic fractionation of butanol fraction of total methanol extract of leaves of Bauhinia variegata (Linn. yields four subfractions (sub-fraction A-D. All sub-fractions tested for their anti-hyperlipidemic activity. Subfractions administered at a dose of 65 mg/kg (oral to the Triton WR-1339 induced hyperlipidemic rats and total cholesterol, triglycerides, HDL, LDL and VLDL level in the blood were checked. Results: Sub-fraction D showed significant reduction (P<0.05 among four sub-fraction in comparison with standard drug fenofibrate. Conclusions: From the above study it could be concluded that butanol sub-fraction D of Bauhinia variegata (Linn. not only have resulted in significant reduction in cholesterol, triglyceride, LDL, VLDL level but also increases the HDL level at a reduced dose level.

  9. Interfacial areas and gas hold-ups in bubble columns and packed bubble columns at elevated pressures

    NARCIS (Netherlands)

    Oyevaar, M.H.; de la Rie, T.; van der Sluijs, C.L.; Westerterp, K.R.

    1989-01-01

    Interfacial areas and gas hold-ups have been determined at pressures up to 1.85 MPa in a bubble column with a diameter of 85.5 mm and for superficial gas velocities between 1 and 10 cm s−1. In some experiments the bubble column was packed with glass cylinders of length 5.0 mm and diameter 4.0 mm.

  10. Input-Output Decoupling of a Distillation Column LV-Configuration

    DEFF Research Database (Denmark)

    Yazdi, H.; Jørgensen, Sten Bay; Bahar (fratrådt), Mehrdad

    1996-01-01

    Introduction, digraph approach, distillation column, digraph analysis, solution analysis, discussion and conclusion, references.......Introduction, digraph approach, distillation column, digraph analysis, solution analysis, discussion and conclusion, references....

  11. Biomechanical investigation of two plating systems for medial column fusion in foot.

    Directory of Open Access Journals (Sweden)

    Paul Simons

    Full Text Available Arthrodesis of the medial column (navicular, cuneiform I and metatarsal I is performed for reasons such as Charcot arthropathy, arthritis, posttraumatic reconstruction or severe pes planus. However, the complication rate is still high and mainly resulting from inadequate fixation. Special plates, designed for medial column arthrodesis, seem to offer potential to reduce the complication rate. The aim of this study was to investigate biomechanically plantar and dorsomedial fusion of the medial column using two new plating systems.Eight matched pairs of human cadaveric lower legs were randomized in two groups and medial column fusion was performed using either plantar or dorsomedial variable-angle locking compression plates. The specimens were biomechanically tested under cyclic progressively increasing axial loading with physiological profile of each cycle. In addition to the machine data, mediolateral x-rays were taken every 250 cycles and motion tracking was performed to determine movements at the arthrodesis site. Statistical analysis of the parameters of interest was performed at a level of significance p = 0.05.Displacement of the talo-navicular joint after 1000, 2000 and 4000 cycles was significantly lower for plantar plating (p≤0.039 while there was significantly less movement in the naviculo-cuneiform I joint for dorsal plating post these cycle numbers (p<0.001. Displacements in all three joints of the medial column, as well as angular and torsional deformations between the navicular and metatarsal I increased significantly for each plating technique between 1000, 2000 and 4000 cycles (p≤0.021. The two plating systems did not differ significantly with regard to stiffness and cycles to failure (p≥0.171.From biomechanical point of view, although dorsomedial plating showed less movement than plantar plating in the current setup under dynamic loading, there was no significant difference between the two plating systems with regard to

  12. A clay permeable reactive barrier to remove Cs-137 from groundwater: Column experiments.

    Science.gov (United States)

    De Pourcq, K; Ayora, C; García-Gutiérrez, M; Missana, T; Carrera, J

    2015-11-01

    Clay minerals are reputed sorbents for Cs-137 and can be used as a low-permeability material to prevent groundwater flow. Therefore, clay barriers are employed to seal Cs-137 polluted areas and nuclear waste repositories. This work is motivated by cases where groundwater flow cannot be impeded. A permeable and reactive barrier to retain Cs-137 was tested. The trapping mechanism is based on the sorption of cesium on illite-containing clay. The permeability of the reactive material is provided by mixing clay on a matrix of wood shavings. Column tests combined with reactive transport modeling were performed to check both reactivity and permeability. Hydraulic conductivity of the mixture (10(-4) m/s) was sufficient to ensure an adequate hydraulic performance of an eventual barrier excavated in most aquifers. A number of column experiments confirmed Cs retention under different flow rates and inflow solutions. A 1D reactive transport model based on a cation-exchange mechanism was built. It was calibrated with batch experiments for high concentrations of NH4+ and K+ (the main competitors of Cs in the exchange positions). The model predicted satisfactorily the results of the column experiments. Once validated, it was used to investigate the performance and duration of a 2 m thick barrier under different scenarios (flow, clay content, Cs-137 and K concentration). Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. A rapid column technique for trapping and collecting of volatile fungal hydrocarbons and hydrocarbon derivatives.

    Science.gov (United States)

    Booth, Eric; Strobel, Gary; Knighton, Berk; Sears, Joe; Geary, Brad; Avci, Recep

    2011-10-01

    A custom-made stainless steel column was designed to contain various materials that would trap the hydrocarbons and hydrocarbon derivatives during the processes of fungal fermentation ultimately yielding preparative amounts of volatile organic substances (VOCs). Trapping materials tested in the column were Carbotrap materials A and B (Supelco) as well as bentonite-shale from the oil bearing areas of Eastern Montana, the former allowed for the effective and efficient trapping of VOCs from purged cultures of Hypoxylon sp. Trapping efficiencies of various materials were measured by both gravimetric as well as proton transfer reaction mass spectroscopy with the Carbotraps A and B being 99% efficient when tested with known amounts of 1,8-cineole. Trapped fungal VOCs could effectively be removed and recovered via controlled heating of the stainless steel column followed by passage of the gases through a liquid nitrogen trap at a recovery rate of ca 65-70%. This method provides for the recovery of mg quantities of compounds normally present in the gas phase that may be needed for spectroscopy, bioassays and further separation and analysis and may have wide applicability for many other biological systems involving VOCs. Other available Carbotraps could be used for other applications. © Springer Science+Business Media B.V. 2011

  14. Salinity and soluble organic matter on virus sorption in sand and soil columns.

    Science.gov (United States)

    Cao, Haibo; Tsai, Frank T-C; Rusch, Kelly A

    2010-01-01

    The objective of this research was to study the sorption and transport of bacteriophage MS-2 (a bacterial virus) in saturated sediments under the effect of salinity and soluble organic matter (SOM). One-dimensional column experiments were conducted on washed high-purity silica sand and sandy soil. In sand column tests, increasing salinity showed distinct effect on enhancing MS-2 sorption. However, SOM decreased MS-2 sorption. Using a two-site reversible-irreversible sorption model and the double layer theory, we explained that pore-water salinity potentially compressed the theoretical thickness of double layers of MS-2 and sand, and thus increased sorption on reversible sorption sites. On irreversible sorption sites, increasing salinity reversed charges of some sand particles from negative to positive, and thus converted reversible sorption sites into irreversible sites and enhanced sorption of MS-2. SOM was able to expand the double layer thickness on reversible sites and competed with MS-2 for the same binding place on irreversible sites. In sandy soil column tests, the bonded and dissolved (natural) soil organic matters suppressed the effects of pore-water salinity and added SOM and significantly reduced MS-2 adsorption. This was explained that the bonded soil organic matter occupied a great portion of sorption sites and significantly reduced sorption sites for MS-2. In addition, the dissolved soil organic matter potentially expanded the double layer thickness of MS-2 and sandy soil on reversible sorption sites and competed with MS-2 for the same binding place.

  15. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations.

    Science.gov (United States)

    Wan, Huihui; Sheng, Qianying; Zhong, Hongmin; Guo, Xiujie; Fu, Qing; Liu, Yanfang; Xue, Xingya; Liang, Xinmiao

    2015-05-01

    The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono-, di-, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. High pressure humidification columns: Design equations, algorithm, and computer code

    Energy Technology Data Exchange (ETDEWEB)

    Enick, R.M. [Pittsburgh Univ., PA (United States). Dept. of Chemical and Petroleum Engineering; Klara, S.M. [USDOE Pittsburgh Energy Technology Center, PA (United States); Marano, J.J. [Burns and Roe Services Corp., Pittsburgh, PA (United States)

    1994-07-01

    This report describes the detailed development of a computer model to simulate the humidification of an air stream in contact with a water stream in a countercurrent, packed tower, humidification column. The computer model has been developed as a user model for the Advanced System for Process Engineering (ASPEN) simulator. This was done to utilize the powerful ASPEN flash algorithms as well as to provide ease of use when using ASPEN to model systems containing humidification columns. The model can easily be modified for stand-alone use by incorporating any standard algorithm for performing flash calculations. The model was primarily developed to analyze Humid Air Turbine (HAT) power cycles; however, it can be used for any application that involves a humidifier or saturator. The solution is based on a multiple stage model of a packed column which incorporates mass and energy, balances, mass transfer and heat transfer rate expressions, the Lewis relation and a thermodynamic equilibrium model for the air-water system. The inlet air properties, inlet water properties and a measure of the mass transfer and heat transfer which occur in the column are the only required input parameters to the model. Several example problems are provided to illustrate the algorithm`s ability to generate the temperature of the water, flow rate of the water, temperature of the air, flow rate of the air and humidity of the air as a function of height in the column. The algorithm can be used to model any high-pressure air humidification column operating at pressures up to 50 atm. This discussion includes descriptions of various humidification processes, detailed derivations of the relevant expressions, and methods of incorporating these equations into a computer model for a humidification column.

  17. Study on application of single-crystal ice 'Kurobe ice column' to high-speed skating rinks. Demonstration test result at Olympic memorial arena 'M wave' in Nagano city. Tankesshohyo 'Kurobe no hyojun' no kosoku skate link eno tekiyosei kenkyu. Naganoshi olympic kinen arina 'Emu Wave' deno jissho shiken kekka

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, M. (Kansai Electric Power Co. Inc., Osaka (Japan))

    1999-06-10

    For high-speed low-friction skating rinks, research was made on sticking artificial ice columns (ice bamboo shoot). The ice columns were fabricated with the ice column production equipment equipped with 4-line water droplet dropping devices which were installed at intervals of 0.3m on both sides of a pathway of 200m long, 2.6m wide and 1.8m high in the lateral adit of Kurobegawa No.4 hydroelectric power station. The grown ice columns were processed for high-speed skating rinks through cutting, confirmation of single crystal and crystal orientation, slicing for every 7mm thickness and packaging. The ice columns were spread all over the rink while sliding them to prevent mixing of bubbles after spraying distilled water of nearly 25 degreesC onto base ices. In addition, hot water of nearly 40 degreesC was sprayed to produce the final ice rink of 30mm thick by nearly 5mm a day. The dynamic friction coefficient of the ice column rink reduced to 0.0038 by nearly 16% as compared with 0.0045 of conventional rinks. (NEDO)

  18. Complex Testing of the Bridges

    Directory of Open Access Journals (Sweden)

    Savić Adrijana

    2016-01-01

    Full Text Available This article describes the process of examining bridges. AB road bridge, founded on the columns by the Karpoš system and damaged due to erosive action of the river, is given as an example. The first tests of the bridge are conducted on the impact load of V 300, because of the appearance of longitudinal cracks. The results of the columns testing are presented in this paper, as well as the rehabilitation measures thus increasing the load capacity of the column.

  19. Bacterial magnetite produced in water column dominates lake sediment mineral magnetism: Lake Ely, USA

    Science.gov (United States)

    Kim, BangYeon; Kodama, Kenneth P.; Moeller, Robert E.

    2005-10-01

    Environmental magnetic studies of annually laminated sediments from Lake Ely, northeastern Pennsylvania, USA indicate that bacterial magnetite is the dominant magnetic mineral in the lake sediment. In previous studies of Lake Ely sediment, the dark, organic-rich layers in the annual laminae were interpreted to have high-intensity saturation isothermal remanent magnetizations (SIRMs) while the light-coloured, silt-rich layers have low-intensity SIRMs. To test the hypothesis that the magnetic grains in the sediments were an authigenic product of magnetotactic bacteria rather than detrital magnetic grains eroded from the watershed, we analysed samples from the water column, the lake sediment, and a sediment trap installed near the lake bottom. Direct microscopic observation of the water column samples showed the presence of magnetotactic bacteria in and below the oxic-anoxic transition zone (OATZ). To characterize the magnetic minerals, rock magnetic parameters were measured for material from the water column, the sediment trap and the dark- and light-coloured lake sediments. Low-temperature magnetic measurements tested for the presence of magnetosomes in separated dark- and light-coloured layer samples. Numeric unmixing of the low-temperature results showed that biogenic magnetites were present in the lake sediment and contributed more significantly to the SIRM in the dark, organic-rich layers than in the light-coloured, inorganic silt-rich layers. Observations under the transmission electron microscope (TEM) of magnetic extracts also show the abundance of magnetosomes in the lake sediment. The presence of live magnetotactic bacteria in the water column and the predominance of bacterial magnetites in filtered particulate matter, sediment traps and recent lake sediment all suggest that bacterial magnetites are the main magnetic minerals in Lake Ely sediment. This finding suggests that changes in environmental factors that control the productivity of magnetic bacteria

  20. A SINGLE-COLUMN PROCEDURE ON BOND ELUT CERTIFY FOR SYSTEMATIC TOXICOLOGICAL ANALYSIS OF DRUGS IN PLASMA AND URINE

    NARCIS (Netherlands)

    CHEN, XH; WIJSBEEK, J; FRANKE, JP; DEZEEUW, RA

    A single-column solid-phase extraction procedure was developed for the screening of acidic, neutral, and basic drugs from plasma. The recoveries of all 25 tested drugs exceeded 82%. After the plasma had been diluted with phosphate buffer (pH 6.0), the drugs were extracted using a single Bond Elut

  1. Optimizing Manpower Allocation for Ground Handling Tasks in Airports using Column Generation

    DEFF Research Database (Denmark)

    Hansen, Anders Dohn; Kolind, Esben

    2008-01-01

    teams/workers, possibly with different skills, is required. This study focuses on the scheduling of ground handling tasks in some of Europe's major airports. Any daily schedule must comply with the time windows and skill requirements of tasks, transportation time between locations, the working hours...... algorithm. 12 authentic data sets from two of Europe's major airports are used for testing. Optimal solutions are found for 11 of the test instances. Keywords: Manpower allocation, crew scheduling, vehicle routing with time windows, synchronization, column generation, Branch-and-Price, time window branching...

  2. Flow Visualization around a Circular Cylinder on the Flow Field of Oscillatory Air Column in the Closed Pipe

    OpenAIRE

    鈴木, 康太郎; 坂口, 勝次; スズキ, コウタロウ; サカグチ, カツジ; Kotaro, SUZUKI; Katsuji, SAKAGUCHI

    2004-01-01

    The experimental investigation of flow visualization around a circular cylinder in the oscillatory flow was carried out. The test cylinder was installed on the center of the passage in the closed pipe with the oscillatory air column. The oscillatory flow near the resonance of air column was produced by a pump which was composed of a crank and piston mechanism as an oscillator. The frequency of the oscillator was changed in the range of 10 to 22.5Hz, and the amplitude of the oscillator was 25m...

  3. The influence of connecting pile cap-column in the mechanisms of break in the two pile caps

    OpenAIRE

    MESQUITA, A. C.; ROCHA,A. S.; DELALIBERA,R. G.; W. A. DA SILVA

    2016-01-01

    Abstract The paper analyzes the two pile caps with partially embedded socket and subject a center load. Three models were experimentally tested, varying the type of conformation of the column and walls of the socket, with a smooth, the other rough, and a monolithic two pile cap, used for reference. The roughening of the column-socket interface was examined with the aim of verifying the difference of the distribution of compressive and tensile stresses in the strut an tie model used for design...

  4. Strengthening Techniques of RC Columns Using Fibre Reinforced Polymeric Materials

    Directory of Open Access Journals (Sweden)

    Ciprian Cozmanciuc

    2009-01-01

    Full Text Available Fibre reinforced composite materials are becoming more frequently used in civil engineering structures. One of the most practical applications of these new materials concerns the strengthening of reinforced concrete columns by means of confinement with fibre composite sheets. In the literature, various theoretical models have been proposed to describe the behaviour of confined concrete columns. The principal advantages of this technique are the high strength-to-weight ratio, good fatigue properties, non-corroding characteristics of the fibre reinforced polymers (FRP, and the facility of its application. The maximum efficiency of confining systems using FRP materials is reached in case of columns with circular cross-section and is explained by the fact that the entire section of the column is involved into the confinement effect. Rectangular confining reinforcement is less efficient as the confinement action is mostly located at the corners This paper reveals the most utilized techniques of performing composite confining systems for reinforced concrete columns, with their advantages and also disadvantages.

  5. Mass transfer kinetics, band broadening and column efficiency.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2012-01-20

    Important progress was recently made in our understanding of the physico-chemical aspects of mass transfer kinetics in chromatographic columns, in methods used for accurate determination of the different contributions to the height equivalent to a theoretical plate (HETP), and in the application of these advances to the elucidation of mass transfer mechanisms in columns packed with recent chromatographic supports (sub-2 μm fully porous particles, sub-3 μm core-shell particles, and monoliths). The independent contributions to the HETP are longitudinal diffusion, eddy dispersion, liquid-solid mass transfer (including trans-particle or trans-skeleton mass transfer and external film mass transfer), and the contributions caused by the thermal heterogeneity of the column. The origin and importance of these contributions are investigated in depth. This work underlines the areas in which improvements are needed, an understanding of the contribution of the external film mass transfer term, a better design of HPLC instruments providing a decrease of the extra-column band broadening contributions to the apparent HETP, the development of better packing procedures giving more radially homogeneous column beds, and new packing materials having a higher thermal conductivity to eliminate the nefarious impact of heat effects in very high pressure liquid chromatography (vHPLC) and supercritical fluid chromatography (SFC). Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Jupiter's great red spot revisited. [validity of Taylor column theory

    Science.gov (United States)

    Hide, R.

    1972-01-01

    On the original Taylor column theory of Jupiter's Great Red Spot, the fixed latitude of the Spot is taken to imply that the Taylor column in Jupiter's atmosphere is associated with a disturbance such as a topographic feature of the surface Q underlying the atmosphere. The alternative suggestion that the Taylor column is produced by a solid raft floating at depth in the atmosphere is somewhat easier to reconcile with the approximately 10s difference between the respective rotation periods P sub S and P sub R of the Red Spot and of the radio sources, but it does not account so readily for the fixed latitude of the Spot unless it can be shown that the raft is in stable equilibrium under the north-south components of the dynamical forces, including wind effects, acting upon it. A slight wavering of the upper end of the Taylor column relative to the lower end could account at least in part for the most rapid variations in P sub S, but the slow large-amplitude variations in P sub S must reflect changes in the longitudinal motion of either the surface Q or of the raft. By generalizing the Proudman-Taylor theorem to the case of a non-homogeneous fluid it is shown that the Taylor column theory does not imply very special and therefore unlikely horizontal and vertical temperature variations in Jupiter's atmosphere, thus refuting a widely-held belief to the contrary.

  7. CFD and CHD in random packing columns with seawater desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Mei-Shan [Southeast Univ., Nanjing (China). College of Civil Engineering; Wang, Shi-He; Wang, Xiao-Ming [State Power Environmental Protection Research Institute, Nanjing (China); Guo, Ming-Chun [Shanghai Huolin engineering Plastics Co., Ltd., Shanghai (China)

    2013-07-01

    By the volume average method, gas-liquid two-phase flow CFD and CHT model is established to describe the random packing column in seawater desulfurization. By numerical calculation, the flow velocity, porosity distribution, pressure distribution and temperature distribution of seawater are obtained. Pressure loss and the outlet temperature of seawater are compared with experimental data, the prediction results and experimental results are well consistent, is exactly the same trend. Analyzing the results of calculation, a significant ''wall flow'' phenomena was found, and the reason of its formation is that the porosity of filler near the wall is significantly higher than in the middle region. Analyzing the distribution of seawater temperature, it is found that the distribution of seawater temperature is more uniform on the top of column, the seawater temperature near the wall fluctuated and were gradually more uniform towards the center of the column. Along the direction of the column from top to bottom, the seawater temperature gradually decreased, and the degree of fluctuations gradually reduced and basically does not change at half of the column, which indicated that the heat exchange between the gas and liquid has been basically completed.

  8. Towards Reconstructing a Doric Column in a Virtual Construction Site

    Science.gov (United States)

    Bartzis, D.

    2017-02-01

    This paper deals with the 3D reconstruction of ancient Greek architectural members, especially with the element of the Doric column. The case study for this project is the Choragic monument of Nicias on the South Slope of the Athenian Acropolis, from which a column drum, two capitals and smaller fragments are preserved. The first goal of this paper is to present some benefits of using 3D reconstruction methods not only in documentation but also in understanding of ancient Greek architectural members. The second goal is to take advantage of the produced point clouds. By using the Cloud Compare software, comparisons are made between the actual architectural members and an "ideal" point cloud of the whole column in its original form. Seeking for probable overlaps between the two point clouds could assist in estimating the original position of each member/fragment on the column. This method is expanded with more comparisons between the reference column model and other members/fragments around the Acropolis, which may have not yet been ascribed to the monument of Nicias.

  9. Insights into Tikhonov regularization: application to trace gas column retrieval and the efficient calculation of total column averaging kernels

    Directory of Open Access Journals (Sweden)

    T. Borsdorff

    2014-02-01

    Full Text Available Insights are given into Tikhonov regularization and its application to the retrieval of vertical column densities of atmospheric trace gases from remote sensing measurements. The study builds upon the equivalence of the least-squares profile-scaling approach and Tikhonov regularization method of the first kind with an infinite regularization strength. Here, the vertical profile is expressed relative to a reference profile. On the basis of this, we propose a new algorithm as an extension of the least-squares profile scaling which permits the calculation of total column averaging kernels on arbitrary vertical grids using an analytic expression. Moreover, we discuss the effective null space of the retrieval, which comprises those parts of a vertical trace gas distribution which cannot be inferred from the measurements. Numerically the algorithm can be implemented in a robust and efficient manner. In particular for operational data processing with challenging demands on processing time, the proposed inversion method in combination with highly efficient forward models is an asset. For demonstration purposes, we apply the algorithm to CO column retrieval from simulated measurements in the 2.3 μm spectral region and to O3 column retrieval from the UV. These represent ideal measurements of a series of spaceborne spectrometers such as SCIAMACHY, TROPOMI, GOME, and GOME-2. For both spectral ranges, we consider clear-sky and cloudy scenes where clouds are modelled as an elevated Lambertian surface. Here, the smoothing error for the clear-sky and cloudy atmosphere is significant and reaches several percent, depending on the reference profile which is used for scaling. This underlines the importance of the column averaging kernel for a proper interpretation of retrieved column densities. Furthermore, we show that the smoothing due to regularization can be underestimated by calculating the column averaging kernel on a too coarse vertical grid. For both

  10. Passive Measurement of CO2 Column from an Airborne Platform

    Science.gov (United States)

    Heaps, William S.; Kawa, S. R.; Wilson, Emily; Georgleva, Elena

    2004-01-01

    We are in the third and final year of our IIP funding to develop a sensor for very precise determination of the CO2 Column. Global measurements of this sort from a satellite platform are needed to improve our understanding of the global carbon budget. In previous reports to this meeting we have described the method by which this system operates and presented data taken during ground based tests of the instrument. Work in the final year has concentrated on building the flight hardened version of the instrument that will be used in our field trials on the Dryden DC-8. The flight unit represents an integration of three channels into a single instrument. These three channels are the CO2 channel, the oxygen pressure sensing channel, and the oxygen temperature sensing channel. Integration of the three channels into a single unit significantly decreases the size of the instrument. The flight unit also employs more rugged optical mounts and integrated optical shielding. Light enters the instrument from below first striking the right angled mirror shown extending over the edge of the platform. The light is then focused through a pinhole to define the instrument field of view, chopped and recollimated. Dichroic mirrors are used to separate the CO2 wavelength from the O2 wavelength and that light is further divided by a 50-50 beamsplitter between the 2 oxygen channels - the pressure channel and the temperature channel. The six white boxes contain the detectors for each of the three channels. The detectors on the left in the photo serve the reference channels and the detectors on the right are for the Fabry-Perots. CO2 is measured by the pair of detectors farthest from the viewer. Pressure via O2 is detected by the central pair of detectors. The closest pair is used to determine temperature via O2.

  11. A method to account for the temperature sensitivity of TCCON total column measurements

    Science.gov (United States)

    Niebling, Sabrina G.; Wunch, Debra; Toon, Geoffrey C.; Wennberg, Paul O.; Feist, Dietrich G.

    2014-05-01

    The Total Carbon Column Observing Network (TCCON) consists of ground-based Fourier Transform Spectrometer (FTS) systems all around the world. It achieves better than 0.25% precision and accuracy for total column measurements of CO2 [Wunch et al. (2011)]. In recent years, the TCCON data processing and retrieval software (GGG) has been improved to achieve better and better results (e. g. ghost correction, improved a priori profiles, more accurate spectroscopy). However, a small error is also introduced by the insufficent knowledge of the true temperature profile in the atmosphere above the individual instruments. This knowledge is crucial to retrieve highly precise gas concentrations. In the current version of the retrieval software, we use six-hourly NCEP reanalysis data to produce one temperature profile at local noon for each measurement day. For sites in the mid latitudes which can have a large diurnal variation of the temperature in the lowermost kilometers of the atmosphere, this approach can lead to small errors in the final gas concentration of the total column. Here, we present and describe a method to account for the temperature sensitivity of the total column measurements. We exploit the fact that H2O is most abundant in the lowermost kilometers of the atmosphere where the largest diurnal temperature variations occur. We use single H2O absorption lines with different temperature sensitivities to gain information about the temperature variations over the course of the day. This information is used to apply a posteriori correction of the retrieved gas concentration of total column. In addition, we show that the a posteriori temperature correction is effective by applying it to data from Lamont, Oklahoma, USA (36,6°N and 97,5°W). We chose this site because regular radiosonde launches with a time resolution of six hours provide detailed information of the real temperature in the atmosphere and allow us to test the effectiveness of our correction. References

  12. Packed-bed column biosorption of chromium(VI) and nickel(II) onto Fenton modified Hydrilla verticillata dried biomass.

    Science.gov (United States)

    Mishra, Ashutosh; Tripathi, Brahma Dutt; Rai, Ashwani Kumar

    2016-10-01

    The present study represents the first attempt to investigate the biosorption potential of Fenton modified Hydrilla verticillata dried biomass (FMB) in removing chromium(VI) and nickel(II) ions from wastewater using up-flow packed-bed column reactor. Effects of different packed-bed column parameters such as bed height, flow rate, influent metal ion concentration and particle size were examined. The outcome of the column experiments illustrated that highest bed height (25cm); lowest flow rate (10mLmin(-1)), lowest influent metal concentration (5mgL(-1)) and smallest particle size range (0.25-0.50mm) are favourable for biosorption. The maximum biosorption capacity of FMB for chromium(VI) and nickel(II) removal were estimated to be 89.32 and 87.18mgg(-1) respectively. The breakthrough curves were analyzed using Bed Depth Service Time (BDST) and Thomas models. The experimental results obtained agree to both the models. Column regeneration experiments were also carried out using 0.1M HNO3. Results revealed good reusability of FMB during ten cycles of sorption and desorption. Performance of FMB-packed column in treating secondary effluent was also tested under identical experimental conditions. Results demonstrated significant reduction in chromium(VI) and nickel(II) ions concentration after the biosorption process. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Seismic Performance of RC Beam-Column Connections with Continuous Rectangular Spiral Transverse Reinforcements for Low Ductility Classes

    Directory of Open Access Journals (Sweden)

    Mohammadamin Azimi

    2014-01-01

    Full Text Available The seismic performance of RC columns could be significantly improved by continuous spiral reinforcement as a result of its adequate ductility and energy dissipation capacity. Due to post-earthquake brittle failure observations in beam-column connections, the seismic behaviour of such connections could greatly be improved by simultaneous application of this method in both beams and columns. In this study, a new proposed detail for beam to column connection introduced as “twisted opposing rectangular spiral” was experimentally and numerically investigated and its seismic performance was compared against normal rectangular spiral and conventional shear reinforcement systems. In this study, three full scale beam to column connections were first designed in conformance with Eurocode (EC2-04 for low ductility class connections and then tested by quasistatic cyclic loading recommended by ACI Building Code (ACI 318-02. Next, the experimental results were validated by numerical methods. Finally, the results revealed that the new proposed connection could improve the ultimate lateral resistance, ductility, and energy dissipation capacity.

  14. FINITE ELEMENT ANALYSIS OF THE BEHAVIOUR OF REINFORCED CONCRETE COLUMNS CONFINED BY OVERLAPPING HOOPS SUBJECTED TO RAPID CONCENTRIC LOADING

    Directory of Open Access Journals (Sweden)

    Xiang Zeng

    2017-12-01

    Full Text Available The strain rate sensitivity of concrete material was discovered approximately one hundred years ago, and it has a marked effect on the behaviour of concrete members subjected to dynamic loadings such as strong earthquake and impact loading. Because of the great importance of the confined reinforced concrete (RC columns in RC structures, the dynamic behaviour of the columns induced by the strain rate effect has been studied, but only few experiments and analyses have been conducted. To investigate the behaviour of overlapping hoop-confined square reinforced normal-strength concrete columns, considering the strain rate effect at a strain rate of 10-5/sec to 10-1/sec induced by earthquake excitation, an explicit dynamic finite element analysis (FEA model was developed in ABAQUS to predict the behaviour of confined RC columns subjected to the rapid concentric loading. A locally modified stress-strain relation of confined concrete with the strain rate sensitivity of the concrete material and the confining effect of overlapping hoops were proposed to complete the simulation of the dynamic behaviour of concrete with the concrete plastic-constitutive model in ABAQUS. The finite element predictions are consistent with the existing test results. Based on the FEA model, a parametric investigation was conducted to capture more information about the behaviour of confined RC columns under varying loading rates.

  15. Adsorption of phosphate from aqueous solutions and sewage using zirconium loaded okara (ZLO): Fixed-bed column study

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T.A.H. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Ngo, H.H., E-mail: ngohuuhao121@gmail.com [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Guo, W.S. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Pham, T.Q. [Faculty of Geography, University of Science, Vietnam National University, Hanoi (Viet Nam); Li, F.M. [College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100 (China); Nguyen, T.V. [Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology, Sydney (UTS), 15 Broadway, Ultimo, NSW 2007 (Australia); Bui, X.T. [Environmental Engineering and Management Research Group, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology-Vietnam National University, Ho Chi Minh City (Viet Nam)

    2015-08-01

    This study explores the potential of removing phosphorus from aqueous solutions and sewage by Zr(IV)-loaded okara (ZLO) in the fixed-bed column. Soybean residue (okara) was impregnated with 0.25 M Zr(IV) solution to prepare active binding sites for phosphate. The effect of several factors, including flow rate, bed height, initial phosphorus concentration, pH and adsorbent particle size on the performance of ZLO was examined. The maximum dynamic adsorption capacity of ZLO for phosphorus was estimated to be 16.43 mg/g. Breakthrough curve modeling indicated that Adams–Bohart model and Thomas model fitted the experimental data better than Yoon–Nelson model. After treatment with ZLO packed bed column, the effluent could meet the discharge standard for phosphorus in Australia. Successful desorption and regeneration were achieved with 0.2 NaOH and 0.1 HCl, respectively. The results prove that ZLO can be used as a promising phosphorus adsorbent in the dynamic adsorption system. - Highlights: • Dynamic adsorption of P from water and wastewater by Zr(IV)-loaded okara was tested. • Effects of column design parameters on the adsorption performance were investigated. • The dynamic adsorption capacity of Zr(IV)-loaded okara for P was reasonably high. • The spent column was effectively regenerated with 0.2 M NaOH followed by 0.1 M HCl. • Zr(IV)-loaded okara column was efficient in eliminating P from municipal sewage.

  16. Bubble column reactor fluid dynamic study at pilot plant scale for residue and extra heavy crude oil upgrading technology

    Energy Technology Data Exchange (ETDEWEB)

    Sardella, R.; Medina, H. [Infrastructure and Upgrading Department PDVSA-Intevep (Venezuela); Zacarias, L.; Paiva, M. [Refining Department. PDVSA-Intevep (Venezuela)

    2011-07-01

    Bubble column reactors are used in several applications because of their simplicity and low cost; a new technology was developed to convert extra heavy crude oil into upgraded crude using a bubble column reactor. To design this kind of reactor, a lot of parameters like flow regime, gas hold up and dispersion coefficient have to be taken into account. This study aimed at determining the fluid dynamic behaviour of a bubble column working under Aquaconversion operating conditions. Experiments were undertaken on air-tap water and air-light oil systems under atmospheric conditions with various gas superficial velocities and liquid flowrates. Results showed that gas hold up increases with superficial gas velocity but is independent of liquid flowrate and that both systems tested work at the same flow regimes. This paper showed that under the experimental conditions used, this reactor tends to be a complete mixing reactor.

  17. Use of biochar amendments for removing bacteria from simulated tile-drainage waters

    Science.gov (United States)

    The addition of biochar has been shown to increase bacterial removal rates by several orders of magnitude in sand-packed columns, suggesting that biochar may be a suitable amendment for use in end-of-tile filter systems to remove indicator and pathogenic microorganisms in tile-drainage waters. Addit...

  18. Sensitivity of the transport and retention of stabilized silver nanoparticles to physicochemical factors

    Science.gov (United States)

    Saturated sand-packed column experiments were conducted to investigate the influence of physicochemical factors on the transport and retention of surfactant stabilized silver nanoparticles (AgNPs). The normalized concentration in breakthrough curves (BTCs) of AgNPs increased with a decrease in solut...

  19. Transport, retention, and long-term release behavior of ZnO nanoparticle aggregates in saturated quartz sand: Role of solution pH and biofilm coating

    Science.gov (United States)

    The transport, retention, and long-term fate of zinc oxide nanoparticles (ZnO-NPs) were investigated in saturated, bare and biofilm (Pseudomonas putida) coated sand packed columns. Almost complete retention of ZnO-NPs occurred in bare and biofilm coated sand when the influent solution pH was 9 and t...

  20. Strengthing of Beams and Columns using GFRP Bars

    Science.gov (United States)

    Nayak, C. B.; Tade, M. K.; Thakare, S. B., Dr.

    2017-08-01

    Nowadays infrastructure development is raising its pace. Many reinforced high concrete and masonry buildings are constructed annually around the globe. There are large numbers of structures which deteriorate or become unsafe to use because of changes in use, changes in loading condition, change in the design configuration, inferior building material used or natural calamities. Thus repairing and retrofitting of these structures for safe usage of has a great market. There are several situations in which a civil structure would require strengthening due to lack of strength, stiffness, ductility and durability. Beams, columns may be strengthened in flexure by using GFRP in tension zone. In this present work comparative study will be made with and without GFRP circular bars in a beam and column. An experiment study will be carried out to study the change in the structural behavior of beams & columns with GFRP circular bars of different thickness, varying span to depth ratio.

  1. ENGINEERING DEVELOPMENT OF SLURRY BUBBLE COLUMN REACTOR (SBCR) TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Bernard A. Toseland, Ph.D.

    1999-01-01

    The major technical objectives of this program are threefold: (1) to develop the design tools and a fundamental understanding of the fluid dynamics of a slurry bubble column reactor to maximize reactor productivity, (2) to develop the mathematical reactor design models and gain an understanding of the hydrodynamic fundamentals under industrially relevant process conditions, and (3) to develop an understanding of the hydrodynamics and their interaction with the chemistries occurring in the bubble column reactor. Successful completion of these objectives will permit more efficient usage of the reactor column and tighter design criteria, increase overall reactor efficiency, and ensure a design that leads to stable reactor behavior when scaling up to large diameter reactors.

  2. Performance analysis of rotating disc contactor (RDC) column

    Science.gov (United States)

    Aiffah, Wan Nurul; Aisyah, Siti; Fashihah, Nor; Anuar, Khairil

    2014-06-01

    Liquid-liquid extraction is one of the most important separation processes. Different kinds of liquid-liquid extrator such as Rotating Disc Contactor (RDC) Column being used in industries. The study of liquid-liquid extraction in an RDC column has be come a very important subject to be discussed not just amongst chemical engineers but mathematicans as well. In this study, the performance of small diameter column RDC using the chemical system involving cumene/isobutryric asid/water are analyzed by the method of design of the experiments (DOE). DOE are applied to estimated the effect of four independent variable; protor speed, flow rate, concentration of continuous inlet and dispersed inlet and their interaction factor to detemine the most significant factor that effect the concentration of continuous and dispersed outlet as output parameters.

  3. ENGINEERING DEVELOPMENT OF SLURRY BUBBLE COLUMN REACTOR (SBCR) TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Bernard A. Toseland

    2002-09-30

    The major technical objectives of this program are threefold: (1) to develop the design tools and a fundamental understanding of the fluid dynamics of a slurry bubble column reactor to maximize reactor productivity, (2) to develop the mathematical reactor design models and gain an understanding of the hydrodynamic fundamentals under industrially relevant process conditions, and (3) to develop an understanding of the hydrodynamics and their interaction with the chemistries occurring in the bubble column reactor. Successful completion of these objectives will permit more efficient usage of the reactor column and tighter design criteria, increase overall reactor efficiency, and ensure a design that leads to stable reactor behavior when scaling up to large diameter reactors.

  4. Estimation of bearing capacity of floating group of stone columns

    Directory of Open Access Journals (Sweden)

    Mohammed Y. Fattah

    2017-06-01

    In the present study, a general equation was obtained by carrying out statistical analysis using the SPSS (Statistical Package for the Social Sciences program from the present experimental work and previous studies. The equation is used to estimate the bearing capacity of floating stone column group installed in clays of different undrained shear strengths between (4–25 kPa and with different diameters and L/D ratios constructed by cased bored method. The equation indicates that the most controlling parameter in the prediction of stone columns bearing capacity, qu, is the area replacement ration, As, where qu increases considerably with increase of As, i.e. decrease of spacing between columns.

  5. Denitrification in the water column of the central Baltic Sea

    DEFF Research Database (Denmark)

    Dalsgaard, Tage; De Brabandere, Loreto; Hall, Per

    2013-01-01

    Removal of fixed nitrogen in the water column of the eastern Gotland Basin, central Baltic Sea, was studied during two cruises in September 2008 and August 2010. The water column was stratified with anoxic sulfidic bottom water meeting oxic nitrate containing water at the oxic–anoxic interface...... View the MathML source or sulfide concentrations were converted to in situ rates using the measured water column concentrations of View the MathML source and sulfide and the actual measured relations between View the MathML source and sulfide concentrations and denitrification rates. In situ...... can be maintained through regular turbulent mixing induced by internal waves at the oxic–anoxic interface. However, layers of up to 55 m thickness with low O2 water (

  6. Denitrification in the water column of the central Baltic Sea

    DEFF Research Database (Denmark)

    Dalsgaard, Tage; De Brabandere, Loreto; Hall, Per O. J.

    2013-01-01

    Removal of fixed nitrogen in the water column of the eastern Gotland Basin, central Baltic Sea, was studied during two cruises in September 2008 and August 2010. The water column was stratified with anoxic sulfidic bottom water meeting oxic nitrate containing water at the oxic–anoxic interface......3 or sulfide concentrations were converted to in situ rates using the measured water column concentrations of NO3 and sulfide and the actual measured relations between NO3 and sulfide concentrations and enitrification rates. In situ denitrification ranged from 0.24 to 15.9 nM N2 h1. Assuming...... at the oxic–anoxic interface. However, layers of up to 55 m thickness with low O2 water (

  7. ENGINEERING DEVELOPMENT OF SLURRY BUBBLE COLUMN REACTOR (SBCR) TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Bernard A. Toseland, Ph.D.

    2000-01-01

    The major technical objectives of this program are threefold: (1) to develop the design tools and a fundamental understanding of the fluid dynamics of a slurry bubble column reactor to maximize reactor productivity, (2) to develop the mathematical reactor design models and gain an understanding of the hydrodynamic fundamentals under industrially relevant process conditions, and (3) to develop an understanding of the hydrodynamics and their interaction with the chemistries occurring in the bubble column reactor. Successful completion of these objectives will permit more efficient usage of the reactor column and tighter design criteria, increase overall reactor efficiency, and ensure a design that leads to stable reactor behavior when scaling up to large diameter reactors.

  8. Use of Computational Fluid Dynamics for Absorption Packed Column Design

    Directory of Open Access Journals (Sweden)

    Haroun Yacine

    2016-05-01

    Full Text Available Computational Fluid Dynamics (CFD is today commonly used in a wide variety of process industries and disciplines for the development of innovative technologies. The present article aims to show how CFD can be used as an effective analysis and design tool for the development and design of packed gas/liquid absorption columns. It is first shown how CFD can be used for the characterisation of packings. The different hydrodynamic and mass transfer design parameters are investigated and adapted CFD methods are suggested. Secondly, column distribution internal development is discussed to show how CFD simulations should be performed to improve the design of gas and liquid distributors. An example of the development of new distribution technologies for floating installation of a reactive absorption column is also presented.

  9. ENGINEERING DEVELOPMENT OF SLURRY BUBBLE COLUMN REACTOR (SBCR) TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Bernard A. Toseland, Ph.D.

    2002-01-01

    The major technical objectives of this program are threefold: (1) to develop the design tools and a fundamental understanding of the fluid dynamics of a slurry bubble column reactor to maximize reactor productivity, (2) to develop the mathematical reactor design models and gain an understanding of the hydrodynamic fundamentals under industrially relevant process conditions, and (3) to develop an understanding of the hydrodynamics and their interaction with the chemistries occurring in the bubble column reactor. Successful completion of these objectives will permit more efficient usage of the reactor column and tighter design criteria, increase overall reactor efficiency, and ensure a design that leads to stable reactor behavior when scaling up to large diameter reactors.

  10. Evaluation of pesticide adsorption in gas chromatographic injector and column

    Directory of Open Access Journals (Sweden)

    Gevany Paulino de Pinho

    2012-01-01

    Full Text Available Components in complex matrices can cause variations in chromatographic response during analysis of pesticides by gas chromatography. These variations are related to the competition between analytes and matrix components for adsorption sites in the chromatographic system. The capacity of the pesticides chlorpyrifos and deltamethrin to be adsorbed in the injector and chromatographic column was evaluated by constructing three isotherms and changing the column heating rate to 10 and 30 ºC min-1. By using ANCOVA to compare the slope of calibration graphs, results showed that the higher the injector temperature (310 ºC the lower the pesticide adsorption. Also, deltamethrin influenced the adsorption of chlorpyrifos on the column chromatographic.

  11. Dynamic Stability of Columns Subjected to Follower Loads: a Survey

    Science.gov (United States)

    LANGTHJEM, M. A.; SUGIYAMA, Y.

    2000-12-01

    This paper offers a survey of simple, flexible structural elements subjected to non-conservative follower loads, such as those caused by the thrust of rocket- and jet engines, and by dry friction in automotive disk- and drum-brake systems. Emphasis is on the “canonical problems”, Beck's, Reut's, Leipholz's, and Hauger's columns. Beck's and Reut's columns have been realized experimentally, and very good agreement between theory and experiments has been found. Leipholz's column is basically realized in an automobile brake system, where noise due to dynamic or parametric instability (brake squeal) is a well-known environmental problem. It is attempted to give a broad overview, with emphasis on experimental works and the associated theoretical problems. Structural optimization is also included in the review, as many studies in that area have served an important purpose in the development of optimization techniques for practical, large-scale optimization problems with non-conservative forces, such as in aeroelasticity.

  12. Experimental Study on Structural Performance of RC Exterior Beam-Column Joints Retrofitted by Steel Jacketing and Haunch Element under Cyclic Loading Simulating Earthquake Excitation

    OpenAIRE

    Dang, Cong-Thuat; Dinh, Ngoc-Hieu

    2017-01-01

    Several retrofitting methods for reinforced concrete (RC) beam-column joints in old buildings without seismic details were developed. Four half-scale RC exterior beam-column joints were fabricated and tested under cyclic loading simulating earthquake excitation. The control specimen was designed to fail in joint shear. Two practical retrofitting strategies were applied to the control specimen which consider the architectural characteristic in real buildings, including steel jacketing and haun...

  13. Eruption column height: a comparison between ground and satellite measurements

    Science.gov (United States)

    Scollo, Simona; Prestifilippo, Michele; Pecora, Emilio; Corradini, Stefano; Merucci, Luca; Spata, Gaetano; Coltelli, Mauro

    2014-05-01

    The eruption column height estimation is an essential parameter to evaluate the total mass eruption rate, the gas and aerosol plume dispersal and retrievals. The column height may be estimated using different systems (e.g. satellite, aircraft and ground observations) which may present marked differences. In this work we use the calibrated images collected by the video-surveillance system of the Istituto Nazionale di Geofisica e Vulcanologia, Osservatorio Etneo, from the visible camera located in Catania, 27 km from the vent. The analysis is carried out on twenty lava fountains from the New South East Crater during the recent Etna explosive activity. Firstly, we calibrated the camera to estimate its intrinsic parameters and the full camera model. Furthermore, we selected the images which recorded the maximum phase of the eruptive activity. Hence, we applied an appropriate correction to take into account the wind effect. The column height was also evaluated using SEVIRI and MODIS satellite images collected at the same time of the video camera measurements. The satellite column height retrievals is realized by comparing the 11 μm brightness temperature of the most opaque plume pixels with the atmospheric temperature profile measured at Trapani WMO Meteo station (the nearest WMO station to the Etnean area). The comparison between satellite and ground data show a good agreement and the column altitudes ranges between 7.5 and 9 km (upper limit of the camera system). For nine events we evaluated also the thickness of the volcanic plumes in the umbrella region (near the vent) which ranges between 2 and 3 km. The proposed approach help to quantitatively evaluate the column height that may be used by volcanic ash dispersal and sedimentation models for improving forecasts and reducing risks to aviation during volcanic crisis.

  14. THE EFFECTS OF ALCOHOL PURIFICATION FROM IMPURITIES IN DEPURATION COLUMN

    Directory of Open Access Journals (Sweden)

    G. V. Agafonov

    2015-01-01

    Full Text Available Currently to the quality of ethyl alcohol increased requirements. The task of this research was to examine the effects of alcohol depuration and development of new methods of calculation based on the model of theoretical plates. The paper examines the work depuration column at different modes. Were composed material balance equation and it is calculated concentration distribution of ethanol on the plates of the column. Further we obtained equations for estimating the effects of ethanol purification from the accompanying impurities. The carries out calculations have shown that when depuration column working with water selection method observed the significant decrease in the concentration of ethanol on her plates. As a result, increases the coefficient evaporation of impurities, which considerably improved it concentration. But it fortress of epurate reduced, which may degrade the performance of the distillation column and result in a loss with the bottoms liquid. It was therefore reviewed variant with the installation of the stripping part on depuration column, thereby increasing the concentration of ethanol in epurate and reduced the content in it of organic acids and other tail impurities that are discharged with liquid from her cube. Having recorded material balance equation for the stripping part, it was determined that are no losses of alcohol with cube liquid are. With some assumptions, from the equations of material balance are obtained the equations allowing estimating proportion of tail impurities withdrawn with cube liquid. The calculations have shown that more than half of the tail impurities incoming to the depuration column removed from her cube.

  15. Modelling soil water content variations under drought stress on soil column cropped with winter wheat

    Directory of Open Access Journals (Sweden)

    Csorba Szilveszter

    2014-12-01

    Full Text Available Mathematical models are effective tools for evaluating the impact of predicted climate change on agricultural production, but it is difficult to test their applicability to future weather conditions. We applied the SWAP model to assess its applicability to climate conditions, differing from those, for which the model was developed. We used a database obtained from a winter wheat drought stress experiment. Winter wheat was grown in six soil columns, three having optimal water supply (NS, while three were kept under drought-stressed conditions (S. The SWAP model was successfully calibrated against measured values of potential evapotranspiration (PET, potential evaporation (PE and total amount of water (TSW in the soil columns. The Nash-Sutcliffe model efficiency coefficient (N-S for TWS for the stressed columns was 0.92. For the NS treatment, we applied temporally variable soil hydraulic properties because of soil consolidation caused by regular irrigation. This approach improved the N-S values for the wetting-drying cycle from -1.77 to 0.54. We concluded that the model could be used for assessing the effects of climate change on soil water regime. Our results indicate that soil water balance studies should put more focus on the time variability of structuredependent soil properties.

  16. Effect of bacterial extracellular polymers on the saturated hydraulic conductivity of sand columns

    Energy Technology Data Exchange (ETDEWEB)

    Vandevivere, P.; Baveye, P. (Cornell Univ., Ithaca, NY (United States))

    1992-05-01

    Columns were packed with clean quartz sand, sterilized, and inoculated with different strains of bacteria, which multiplied within the sand at the expense of a continuous supply of fresh nutrient medium. The saturated hydraulic conductivity (HC[sub sat]) of the sand was monitored over time. Among the four bacterial strains tested, one formed a capsule, one produced slime layers, and two did not produce any detectable exopolymers. The last two strains were nonmucoid variants of the first two. Only one strain, the slime producer, had a large impact on the HC[sub sat]. The production of exopolymers had no effect on either cell multiplication within or movement through the sand columns. Therefore, the HC[sub sat] reduction observed with the slime producer was tentatively attributed to the obstruction of flow channels with slime. Compared with the results with Arthrobacter sp. strain AK19 used in a previous study, there was a 100-fold increase in detachment from the solid substratum and movement through the sand of the strains used in this study. All strains induced severe clogging when they colonized the inlet chamber of the columns. Under these conditions, the inlet end was covered by a confluent mat with an extremely low HC[sub sat].

  17. Effect of bacterial extracellular polymers on the saturated hydraulic conductivity of sand columns.

    Science.gov (United States)

    Vandevivere, P; Baveye, P

    1992-05-01

    Columns were packed with clean quartz sand, sterilized, and inoculated with different strains of bacteria, which multiplied within the sand at the expense of a continuous supply of fresh nutrient medium. The saturated hydraulic conductivity (HCsat) of the sand was monitored over time. Among the four bacterial strains tested, one formed a capsule, one produced slime layers, and two did not produce any detectable exopolymers. The last two strains were nonmucoid variants of the first two. Only one strain, the slime producer, had a large impact on the HCsat. The production of exopolymers had no effect on either cell multiplication within or movement through the sand columns. Therefore, the HCsat reduction observed with the slime producer was tentatively attributed to the obstruction of flow channels with slime. Compared with the results with Arthrobacter sp. strain AK19 used in a previous study, there was a 100-fold increase in detachment from the solid substratum and movement through the sand of the strains used in this study. All strains induced severe clogging when they colonized the inlet chamber of the columns. Under these conditions, the inlet end was covered by a confluent mat with an extremely low HCsat.

  18. Performance of Elaeis Guineensis Leaves Compost in Filter Media for Stormwater Treament Through Column Study

    Science.gov (United States)

    Takaijudin, H.; Ghani, A. A.; Zakaria, N. A.; Tze, L. L.

    2016-07-01

    Compost based materials arv e widely used in filter media for improving soil capability and plant growth. The aim of this paper is to evaluate different types of compost materials used in engineered soil media through soil column investigation. Three (3) column, namely C1 (control), C2 and C3 had different types compost (10%) which were, commercial compost namely PEATGRO, Compost A and Compost B were prepared with 60% medium sand and 30% of topsoil. The diluted stormwater runoff was flushed to the columns and it was run for six (6) hour experiment. The influent and effluent samples were collected and tested for Water Quality Index (WQI) parameters. The results deduced that C3 with Elaeis Guineensis leaves compost (Compost B) achieved 90.45 (Class II) better than control condition which accomplished 84 (Class II) based on WQI Classification. C3 with Compost A (African Mahogany Leaves Compost) obtained only 59.39 (Class III). C3 with the composition of Compost B effectively removed most pollutants, including Chemical Oxygen Demand (COD, Ammoniacal Nitrogen (NH3-N), were reduced by 89±4% and 96.6±0.9%, respectively. The result concluded that Elaeis Guineensis leaves compost is recommended to be used as part of engineered soil media due to its capabilities in eliminating stormwater pollutants.

  19. Heat storage in the Hettangian aquifer in Berlin - results from a column experiment

    Science.gov (United States)

    Milkus, Chri(Sch)augott

    2015-04-01

    Aquifer Thermal Energy Storage (ATES) is a sustainable alternative for storage and seasonal availability of thermal energy. However, its impact on the subsurface flow regime is not well known. In Berlin (Germany), the Jurassic (Hettangian) sandstone aquifer with highly mineralized groundwater (TDS 27 g/L) is currently used for heat storage. The aim of this study was to examine the hydrogeochemical changes that are caused by the induced temperature shift and its effects on the hydraulic permeability of the aquifer. Column experiments were conducted, in which stainless steel columns were filled with sediment from the aquifer and flushed with native groundwater for several weeks. The initial temperature of the experiment was 20°C, comparable to the in-situ conditions within the aquifer. After reaching equilibrium between sediment and water, the temperature was increased to simulate heating of the aquifer. During the experiment, physical and chemical parameters (pH, ORP, dissolved oxygen and dissolved carbon dioxide) were measured at the outflow of the column and the effluent water was sampled. Using a Scanning Electron Microscope, the deposition of precipitated minerals and biofilm on sediment grains was analyzed. Changes in hydraulic properties of the sediment were studied by the use of tracer tests with Uranin.

  20. Experimental Study on Variation Rules of Damping with Influential Factors of Tuned Liquid Column Damper

    Directory of Open Access Journals (Sweden)

    Yang Yu

    2017-01-01

    Full Text Available A tuned liquid column damper (TLCD is a more effective form of passive control for structural vibration suppression and may be promising for floating platform applications. To achieve good damping effects for a TLCD under actual working conditions, factors that influence the damping characteristics need to be identified. In this study, the relationships between head loss coefficients and other factors such as the total length of the liquid column, opening ratio, Reynolds number, Kc number, and horizontal length of the liquid column were experimentally investigated. By using a hydraulic vibration table, a vibration test system with large-amplitude motion simulation, low-frequency performance, and large stroke force (displacement control is devised with a simple operation and at low cost. Based on the experimental method of uniform design, a series of experimental studies were conducted to determine the quantitative relationships between the head loss coefficient and other factors. In addition, regression analyses indicated the importance of each factor affecting the head loss coefficient. A rapid design strategy of TLCD head loss coefficient is proposed. This strategy can help people conveniently and efficiently adjust the head loss coefficient to a specified value to effectively suppress vibration.

  1. The analysis of scaling mechanism for water-injection pipe columns in the Daqing Oilfield

    Directory of Open Access Journals (Sweden)

    Guolin Jing

    2017-02-01

    Full Text Available Although water-injection in mature reservoirs is a promising low-cost method of enhanced oil recovery (EOR, in the process of development in the oilfield, scale has been produced in water-injection pipe columns. The ability to prevent and control the deposition of scale is critical to the efficient recovery of crude oil from hard environments, as part of the broader discipline of “flow assurance” in the petroleum industry. To this end laboratory-scale deposition tests have been useful to understand scale deposition mechanism. The process, mechanism and the main type of the scale in water-injection pipe columns of the fifth plant of the Daqing Oilfield were analyzed. The effect of temperature on the possibility of carbonate calcium formation on oil recovery was investigated experimentally. One of the scale samples was characterized by electron spectroscopy and the results of the element analysis were investigated. Moreover, the precautionary and control measures of scaling in oilfield pipe column systems are proposed.

  2. A new fully automated FTIR system for total column measurements of greenhouse gases

    Directory of Open Access Journals (Sweden)

    M. C. Geibel

    2010-10-01

    Full Text Available This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON. It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics.

    Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control.

    First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months.

    After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  3. Brain Emotional Learning Based Intelligent Decoupler for Nonlinear Multi-Input Multi-Output Distillation Columns

    Directory of Open Access Journals (Sweden)

    M. H. El-Saify

    2017-01-01

    Full Text Available The distillation process is vital in many fields of chemical industries, such as the two-coupled distillation columns that are usually highly nonlinear Multi-Input Multi-Output (MIMO coupled processes. The control of MIMO process is usually implemented via a decentralized approach using a set of Single-Input Single-Output (SISO loop controllers. Decoupling the MIMO process into group of single loops requires proper input-output pairing and development of decoupling compensator unit. This paper proposes a novel intelligent decoupling approach for MIMO processes based on new MIMO brain emotional learning architecture. A MIMO architecture of Brain Emotional Learning Based Intelligent Controller (BELBIC is developed and applied as a decoupler for 4 input/4 output highly nonlinear coupled distillation columns process. Moreover, the performance of the proposed Brain Emotional Learning Based Intelligent Decoupler (BELBID is enhanced using Particle Swarm Optimization (PSO technique. The performance is compared with the PSO optimized steady state decoupling compensation matrix. Mathematical models of the distillation columns and the decouplers are built and tested in simulation environment by applying the same inputs. The results prove remarkable success of the BELBID in minimizing the loops interactions without degrading the output that every input has been paired with.

  4. Oscillations of Magnetic Fluid Column in Strong Magnetic Field

    Science.gov (United States)

    Polunin, V. M.; Storozhenko, A. M.; Platonov, V. B.; Lobova, O. V.; Ryapolov, P. A.

    2017-01-01

    The paper considers the results of measuring the elastic parameters (ponderomotive elasticity coefficient, oscillation frequency, attenuation coefficient) of the oscillatory system with an inertial element that is a magnetic fluid column retained in a tube due to magnetic levitation in a strong magnetic field. Elasticity is provided by the ponderomotive force which affects the upper and lower thin layers of the fluid column. Measurement results of vibration parameters of the oscillatory system can be useful for the investigations of magnetophoresis and aggregation of nanoparticles in magnetic fluids.

  5. Column experiments on organic micropollutants - applications and limitations

    Science.gov (United States)

    Banzhaf, Stefan; Hebig, Klaus

    2016-04-01

    As organic micropollutants become more and more ubiquitous in the aquatic environment, a sound understanding of their fate and transport behaviour is needed. This is to assure both safe and clean drinking water supply for mankind in the future and to protect the aquatic environment from pollution and negative consequences caused by manmade contamination. Apart from countless field studies, column experiments were and are frequently used to study transport of organic micropollutants. As the transport of (organic) solutes in groundwater is controlled by the chemical and physical properties of the compounds, the solvent (the groundwater including all solutes), and the substrate (the aquifer material), the adjustment and control of these boundary conditions allow to study a multitude of different experimental setups and to address specific research questions. The main purpose, however, remains to study the transport of a specific compound and its sorption and degradation behaviour in a specific sediment or substrate. Apart from the effective control of the individual boundary conditions, the main advantage of columns studies compared to other experimental setups (such as field studies, batch/microcosm studies), is that conservative and reactive solute breakthrough curves are obtained, which represent the sum of the transport processes. The analysis of these curves is well-developed and established. Additionally, limitations of this experimental method are presented here: the effects observed in column studies are often a result of dynamic, non-equilibrium processes. Time (or flow velocity) plays a major role in contrast to batch experiments, in which all processes will be observed until equilibrium is reached in the substrate-solution-system. Slightly modifying boundary conditions in different experiments have a strong influence on transport and degradation behaviour of organic micropollutants. This is a significant severe issue when it comes to general findings on the

  6. Thermodynamic analysis of multicomponent distillation columns: identifying optimal feed conditions

    Directory of Open Access Journals (Sweden)

    M. L.O. Maia

    2000-12-01

    Full Text Available A new methodology for the optimisation of feed conditions as well as the calculation of minimum reflux ratio of distillation columns is presented. The reversible profile approach used for saturated liquid feeds is extended to consider other feed conditions. For flashed feed, the liquid fraction of the feed stream is used to compute the column pinch conditions and the minimum reflux ratio. The modifications required for subcooled liquid and superheated vapor feed are discussed, and a procedure to estimate the minimum reflux for those conditions is proposed. The methodology presented allows the identification of the optimal feed condition, without having to resort to a full stage-by-stage procedure.

  7. Low-frequency flute instabilities of a bounded plasma column.

    Science.gov (United States)

    Rognlien, T. D.

    1973-01-01

    Derivation of exact solutions for unstable waves (called flute waves) which occur in a radially bounded plasma column at frequencies below the ion cyclotron frequency. Both analytical and numerical solutions are presented for the m = 1 and m = 2 azimuthal modes for a variety of radial electric field profiles. It is shown that the behavior of the flute waves can depend sensitively on the radial extent of the plasma column. Moreover, it is found that the m = 1 mode and the m = 2 mode do not respond in the same way to changes in the radial boundary position or in the electric field profile.

  8. Bioretention column study of bacteria community response to salt-enriched artificial stormwater.

    Science.gov (United States)

    Endreny, Theodore; Burke, David J; Burchhardt, Kathleen M; Fabian, Mark W; Kretzer, Annette M

    2012-01-01

    Cold climate cities with green infrastructure depend on soil bacteria to remove nutrients from road salt-enriched stormwater. Our research examined how bacterial communities in laboratory columns containing bioretention media responded to varying concentrations of salt exposure from artificial stormwater and the effect of bacteria and salt on column effluent concentrations. We used a factorial design with two bacteria treatments (sterile, nonsterile) and three salt concentrations (935, 315, and 80 ppm), including a deionized water control. Columns were repeatedly saturated with stormwater or deionized and then drained throughout 5 wk, with the last week of effluent analyzed for water chemistry. To examine bacterial communities, we extracted DNA from column bioretention media at time 0 and at week 5 and used molecular profiling techniques to examine bacterial community changes. We found that bacterial community taxa changed between time 0 and week 5 and that there was significant separation between taxa among salt treatments. Bacteria evenness was significantly affected by stormwater treatment, but there were no differences in bacterial richness or diversity. Soil bacteria and salt treatments had a significant effect on the effluent concentration of NO, PO, Cu, Pb, and Zn based on ANOVA tests. The presence of bacteria reduced effluent NO and Zn concentrations by as much as 150 and 25%, respectively, while having a mixed effect on effluent PO concentrations. Our results demonstrate how stormwater can affect bacterial communities and how the presence of soil bacteria improves pollutant removal by green infrastructure. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  9. Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

    Directory of Open Access Journals (Sweden)

    Ke Su

    Full Text Available The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate.Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1 a reconstruction plate, 2 a reconstruction plate with a posterior column lag screw, 3 double reconstruction plates, and 4 a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force.Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524, both of which were superior to a single reconstruction plate (248.90±61.95 N/mm and a combined plate and lag screw (326.41±94.34 N/mm. Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05, a single reconstruction plate with lag screw (p<0.05, and two reconstruction plates (p<0.05.The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.

  10. The effects of flow rate and concentration on nitrobenzene removal in abiotic and biotic zero-valent iron columns.

    Science.gov (United States)

    Yin, Weizhao; Wu, Jinhua; Huang, Weilin; Li, Yongtao; Jiang, Gangbiao

    2016-08-01

    This study investigated the effects of varying nitrobenzene (NB) loadings via increasing flow rate or influent NB concentration mode on the removal efficiency in zero-valent iron (ZVI) columns sterilized (abiotic) or preloaded with acclimated microorganisms (biotic). It was shown that physical sequestration via adsorption/co-precipitation and reductive transformation of NB to aniline (AN) were the two major mechanisms for the NB removal in both abiotic and biotic ZVI columns. The NB removal efficiency decreased in both columns as the flow rate increased from 0.25 to 1.0mLmin(-1) whereas the AN recovery increased accordingly, with relatively high AN recovery observed at the flow rate of 1.0mLmin(-1). At the constant flow rate of 0.5mLmin(-1), increasing influent NB concentration from 80 to 400μmolL(-1) resulted in decreasing of the overall NB removal efficiency from 79.5 to 48.6% in the abiotic column and from 85.6 to 62.5% in the biotic column. The results also showed that the sequestration capacity and chemical reduction capacity were respectively 72% and 157.6% higher in the biotic column than in the abiotic column at the same tested hydraulic conditions and NB loadings. The optimal flow rates and influent NB concentrations were at 0.5mLmin(-1) and 80μmolL(-1) for the abiotic column and 2.0mLmin-1 and 240μmolL(-1) for the biotic column, respectively. This study indicated that microorganisms not only enhanced overall reduction of NB, but also facilitated NB sequestration within the porous media and that the optimal loading conditions for overall removal, sequestration, and reduction of NB may be different. Optimal operation conditions should be found for preferred sequestration or transformation (or both) of the target contaminants to meet different goals of groundwater remediation with the ZVI-PRB systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Tests in Print II: An Index to Tests, Test Reviews, and the Literature on Specific Tests.

    Science.gov (United States)

    Buros, Oscar K., Ed.

    Tests in Print II is a comprehensive, annotated bibliography of all in-print tests published as separates for use with English-speaking subjects. The 1,155 two-column pages list 2,467 tests in print as of early 1974; 16,574 references through 1971 on specific tests; a reprinting of the 1974 APA-AERA-NCME Standards for Educational andPsychological…

  12. Damage assessment for seismic response of recycled concrete filled steel tube columns

    Science.gov (United States)

    Huang, Yijie; Xiao, Jianzhuang; Shen, Luming

    2016-09-01

    A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the effect of repeated cyclic loading into account. Available test results were collected and utilized to calibrate the parameters of the proposed model. A seismic test for six RCFST columns was also performed to validate the proposed damage assessment model. The main test parameters were the recycled coarse aggregate (RCA) replacement percentage and the bond-slip property. The test results indicated that the seismic performance of the RCFST member depends on the RCA contents and their damage index increases as the RCA replacement percentage increases. It is also indicated that the damage degree of RCFST changes with the variation of the RCA replacement percentage. Finally, comparisons between the RCA contents, lateral deformation ratio and damage degree were implemented. It is suggested that an improvement procedure should be implemented in order to compensate for the performance difference between the RCFST and normal concrete filled steel tubes (CFST).

  13. Technological and energetic improvement of a propylene distillation column

    Directory of Open Access Journals (Sweden)

    Ostrovski Nikolaj

    2005-01-01

    Full Text Available A multicomponent distillation column for propylene purification was optimized in order to increase its energetic effectively. The ©-method coupled with the Soave-Redlich-Kwong equation of state for generating K-values and enthalpies was used. The optimal combination of pressure, temperature and reflux flow provided the decrease of steam consumption and loss of propylene with bottom flow.

  14. Exterior beam-column joint study with non-conventional ...

    Indian Academy of Sciences (India)

    ing technique for non-seismically detailed beam-column joints of existing reinforced concrete buildings using pre-fabricated SIFCON composite blocks. The anchorage requirements for the beam longitudinal reinforcement bar and joint core details are the main issues found from the literature reviewed for the problem of ...

  15. Active Disturbance Rejection Control of a Heat Integrated Distillation Column

    DEFF Research Database (Denmark)

    Al-Kalbani, Fahad; Zhang, Jie; Bisgaard, Thomas

    2016-01-01

    Heat integrated distillation column (HiDC) is the most energy efficient distillation approach making efficient utilization of internal heat integration through heat pump. The rectifying section acts as a heat source with high pressure, while the stripping section operates as a heat sink with low...

  16. Overall plate efficiency of a binary distillation column: new approach ...

    African Journals Online (AJOL)

    New formulae for the determination of both tray and overall plate efficiencies of a binary distillation column are presented. They only require the liquid and vapour phases concentrations of the more volatile component on each tray and assumption of constant relative volatility for their use. The new formulae gave very close ...

  17. Continuous and Batch Distillation in an Oldershaw Tray Column

    Science.gov (United States)

    Silva, Carlos M.; Vaz, Raquel V.; Santiago, Ana S.; Lito, Patricia F.

    2011-01-01

    The importance of distillation in the separation field prompts the inclusion of distillation experiments in the chemical engineering curricula. This work describes the performance of an Oldershaw column in the rectification of a cyclohexane/n-heptane mixture. Total reflux distillation, continuous rectification under partial reflux, and batch…

  18. Nonlinear analysis of shear deformable beam-columns partially ...

    African Journals Online (AJOL)

    In this paper, a boundary element method is developed for the nonlinear analysis of shear deformable beam-columns of arbitrary doubly symmetric simply or ... Application of the boundary element technique yields a system of nonlinear equations from which the transverse and axial displacements are computed by an ...

  19. Plecospondylic spinal column in the viviparous Cyprinodont Lebistes reticulatus (Peters)

    NARCIS (Netherlands)

    Stolk, A.

    1955-01-01

    Description of a case of plecospondylic spinal column in the viviparous Cyprinodont Lebistes reticulatus (PETERS), the so-called guppy or millionfish. In this deformity the following phenomena have been observed: displacement of vertebrae, transformation of vertebrae, increase in size of vertebrae,

  20. Learning Earthquake Design and Construction–How do Columns in ...

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 10; Issue 6. Learning Earthquake Design and Construction – How do Columns in RC Buildings Resist Earthquakes? C V R Murty. Classroom Volume 10 Issue 6 June 2005 pp 78-81 ...

  1. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  2. A column-store meets the point clouds

    NARCIS (Netherlands)

    Martinez-Rubi, O.; Kersten, M.L.; Goncalves, R.; Ivanova, M.

    2014-01-01

    Column stores have become the de-facto standard for most datawarehouse solutions. The regularity and query patterns of LIDAR data are a potential application area well suited for this technology. In this short work in progress paper we report on our experiences in supporting point cloud data using

  3. 175 Years of Linear Programming-Pivots in Column Space

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 1. 175 Years of Linear Programming - Pivots in Column Space. Vijay Chandru M R Rao. Series Article Volume 4 Issue 1 January 1999 pp 8-22. Fulltext. Click here to view fulltext PDF. Permanent link:

  4. Exterior beam-column joint study with non-conventional ...

    Indian Academy of Sciences (India)

    Reinforced concrete structures beam-column joints are the most critical regions in seismic prone areas. Proper reinforcement anchorage is essential to enhance the performance of the joints. An attempt has been made to appraise the performance of the anchorages and joints. The anchorages are detailed as per ACI-352 ...

  5. METHODS FOR EXPERIMENTAL ANASTOMOSES PROTECTION ON THE COLUMN

    Directory of Open Access Journals (Sweden)

    Milan Višnjić

    2002-03-01

    Full Text Available The paper presents the results of an experimental research on small animals (rats whose purpose is to check upon efficiency of the protection methods for suppressing dehiscence of the column anastomoses.The research is carried out on 90 experimental animals divided into three groups of 30. In the control group (group K the segment resection of the left side of the column is done with termino-terminal anastomosis by a one-layer extension suture. In the II animal group the anastomosis protection is done by intraluminal application of latex prosthesis (group L and in the III group the fibrin adhesive or bio adhesive application is done (group F. The complete dehiscence of anastomosis as the cause of mortality in the group K is registered in 3 (10% cases while in the group L in 2 (6,6% animals. In the group F there is no dehiscence with the energence of diffuse peritonitis. By applying the protection methods in performing on the column better results are achieved and they are manifested in a smaller number of dehiscences. The local application of the fibrin adhesive provides for the best results since the good mechanical protection is achieved while at the same time the healing time of the column anastomoses is shortened.

  6. FRP Composites Strengthening of Concrete Columns under Various Loading Conditions

    Directory of Open Access Journals (Sweden)

    Azadeh Parvin

    2014-04-01

    Full Text Available This paper provides a review of some of the progress in the area of fiber reinforced polymers (FRP-strengthening of columns for several loading scenarios including impact load. The addition of FRP materials to upgrade deficiencies or to strengthen structural components can save lives by preventing collapse, reduce the damage to infrastructure, and the need for their costly replacement. The retrofit with FRP materials with desirable properties provides an excellent replacement for traditional materials, such as steel jacket, to strengthen the reinforced concrete structural members. Existing studies have shown that the use of FRP materials restore or improve the column original design strength for possible axial, shear, or flexure and in some cases allow the structure to carry more load than it was designed for. The paper further concludes that there is a need for additional research for the columns under impact loading senarios. The compiled information prepares the ground work for further evaluation of FRP-strengthening of columns that are deficient in design or are in serious need for repair due to additional load or deterioration.

  7. Power Plant Emission Monitoring in Munich Using Differential Column Measurements

    Science.gov (United States)

    Chen, Jia; Nguyen, Hai; Toja-Silva, Francisco; Heinle, Ludwig; Hase, Frank; Butz, André

    2017-04-01

    Differential column measurements using compact Fourier transform spectrometers (EM27/SUN) have shown to be an effective method to determine the greenhouse gas emissions. Citywide measurement campaigns were carried out in Boston, Indianapolis, San Francisco, etc., focusing on city (e.g. emissions from natural gas infrastructure) and local sources. We are particularly working on validating this novel method for attributing and quantifying local emission sources. Optimal strategies are developed for measuring in different seasons with various sun elevations. We have deployed two spectrometers to monitor the CO2 and CH4 emission rates (kg s-1) of a natural gas fired combined heat-and-power plant in Munich, Germany (Heizkraftwerk Süd). We placed our spectrometers in the vicinity (emission rates agree well with our a priori knowledge of the inflow. In this work, we discuss the accuracy of the differential column measurements for determining power plant emissions and explore their sensitivities to meteorological and model parameters. In addition, we present measurement strategies and experimental design criteria for different meteorological conditions and time of the year, including winter when the sun elevation is low and the column inclination becomes very important. Differential column measurements using compact spectrometers are shown to be a reliable method to monitor power plant emissions.

  8. Column planarity and partially-simultaneous geometric embedding

    Czech Academy of Sciences Publication Activity Database

    Barba, L.; Evans, W.; Hoffmann, M.; Kusters, V.; Saumell, Maria; Speckmann, B.

    2017-01-01

    Roč. 21, č. 6 (2017), s. 983-1002 ISSN 1526-1719 Grant - others:GA MŠk(CZ) LO1506; GA MŠk(CZ) EE2.3.30.0038 Institutional support: RVO:67985807 Keywords : column planarity * unlabeled level planarity * simultaneous geometric embedding Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics

  9. Convergence analysis for column-action methods in image reconstruction

    DEFF Research Database (Denmark)

    Elfving, Tommy; Hansen, Per Christian; Nikazad, Touraj

    2016-01-01

    Column-oriented versions of algebraic iterative methods are interesting alternatives to their row-version counterparts: they converge to a least squares solution, and they provide a basis for saving computational work by skipping small updates. In this paper we consider the case of noise-free data...

  10. Ether lipids of planktonic archae in the marine water column

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Hoefs, M.J.L.; Schouten, S.; King, L.L.; Wakeham, S.G.; Leeuw, J.W. de

    1997-01-01

    Acyclic and cyclic biphytanes derived from the membrane ether lipids of archaea were found in water column particulate and sedimentary organic matter from several oxic and anoxic marine environments. Compound-specific isotope analyses of the carbon skeletons suggest that planktonic archaea utilize

  11. The intelligent estimating of spinal column abnormalities by using ...

    African Journals Online (AJOL)

    Spinal column abnormities such as kyphosis and lordosis are the most common deformity that normally compare to the standard norms. To classify the subjects into the healthy and abnormal groups based on the angle values of the standard norms, the aim of this study was to use the artificial neural network method as a ...

  12. Constructing victims and perpetrators of rape in the advice column

    African Journals Online (AJOL)

    Kate H

    Abstract. This article reports on the ways in which the rape of women by men is constructed in the advice column Dear Dolly, published in the South African periodical Drum Magazine. The data collected for the study spans from 1984 to 2004, encompassing both 10 years before and 10 years after the onset of democracy in ...

  13. Alpine glacial topography and the rate of rock column uplift

    DEFF Research Database (Denmark)

    Pedersen, Vivi Kathrine; Egholm, D.L.; Nielsen, S.B.

    2010-01-01

    The present study investigates the influence of alpine glacial erosion on the morphology and relief distribution of mountain regions associated with varying rock column uplift rates. We take a global approach and analyse the surface area distribution of all mountain regions affected by glacial er...

  14. Pre-, on- and post-column derivatization in capillary electrophoresis.

    NARCIS (Netherlands)

    Bardelmeijer, H.A.; Waterval, J.C.M.; Lingeman, H.; van 't Hof, R.; Bult, A.; Underberg, W.J.M.

    1997-01-01

    This survey gives a short overview of the various reagents and procedures that can be used for pre-, post- and on-column derivatization in capillary electrophoresis. First there is an introduction about capillary electrophoresis as an analytical technique; this is followed by a discussion of the

  15. Water column correction for coral reef studies by remote sensing.

    Science.gov (United States)

    Zoffoli, Maria Laura; Frouin, Robert; Kampel, Milton

    2014-09-11

    Human activity and natural climate trends constitute a major threat to coral reefs worldwide. Models predict a significant reduction in reef spatial extension together with a decline in biodiversity in the relatively near future. In this context, monitoring programs to detect changes in reef ecosystems are essential. In recent years, coral reef mapping using remote sensing data has benefited from instruments with better resolution and computational advances in storage and processing capabilities. However, the water column represents an additional complexity when extracting information from submerged substrates by remote sensing that demands a correction of its effect. In this article, the basic concepts of bottom substrate remote sensing and water column interference are presented. A compendium of methodologies developed to reduce water column effects in coral ecosystems studied by remote sensing that include their salient features, advantages and drawbacks is provided. Finally, algorithms to retrieve the bottom reflectance are applied to simulated data and actual remote sensing imagery and their performance is compared. The available methods are not able to completely eliminate the water column effect, but they can minimize its influence. Choosing the best method depends on the marine environment, available input data and desired outcome or scientific application.

  16. Thermal Analysis for Ion-Exchange Column System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Si Y.; King, William D.

    2012-12-20

    Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models were used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.

  17. Plecospondylic spinal column in the eel Anguilla anguilla

    NARCIS (Netherlands)

    Stolk, A.

    1956-01-01

    Several cases of deformities in the spinal column were described in fishes, viz. lordosis in the bitterling Rhodeus amarus) by ROTH (1922), in the minnow (Phoxinus phoxinus) by ROTH (1922), in the pike (Esox lucius) by ROTH (1922) and PLEHN (1924); kyphosis in the toothcarps (Cyprinodontidae) by

  18. Finite Element Studies on Hollow Steel Columns under Multi ...

    African Journals Online (AJOL)

    Herein, finite element (FE) modeling of the columns under multi-directional loading is conducted employing ABAQUS FE code in conjunction with the experimental results. To optimize on the program capabilities, the sensitivity of the developed model is appraised with regard to the effect of type of shell element, type of ...

  19. CONTINUOUS PRODUCTION OF PURE SQUALENE BY USING COLUMN CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Dosis Undjung

    2010-06-01

    Full Text Available The purpose of this research was to produce pure Squalene using the Chromatography Column of Continuous System, so that it will be applicable in home industry. The raw material was a Shark caught from the sea water in Katingan Regency, Central Kalimantan. The result of this research concludes that the Column Chromatography of Continuous System in the experiment was able to produce pure Squalene with the level of purification of 79.89 % out of raw material was as long 180 minutes, by the elution speed of 4 mL per minute, and the eluen (liquid of the raw material needed was as much as 900 mL, the solution lost (2 % of dietil eter in benzene during the process was 2.04 %, the temperature in the heater tube was 110 oC, the number of the Silica gel G 40 types as what so-called solid phase in this process to purify 90 g of raw material was 90 g, and the amount of the solution remained in the pure Squalene was 1.5 ppm. Column Chromatography of Continuous System may be applicable in home industry to produce pure Squalene from Shark Liver Oil, the materials and equipment for this activity can be easily found as they are available in markets. A further analysis is needed to find out of contained compound for its further use.   Keywords: pure squalene, continuous system, column chromatography

  20. Design chart procedures for polygonal concrete-filled steel columns ...

    African Journals Online (AJOL)

    High quality moment-axial -force interaction diagrams have been developed for hexagonal and octagonal steel-concrete composite columns subjected to uniaxial bending. Comparative discussion with the procedures stipulated in relevant building code standards has been presented. A unified approach has been ...